mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-09 13:01:50 +00:00
Redline AN50 wireless backhaul
This commit is contained in:
parent
66e36be822
commit
77885ab846
946
snmp_mib_archive/REDLINE_AN50_PTP_MIB.txt
Normal file
946
snmp_mib_archive/REDLINE_AN50_PTP_MIB.txt
Normal file
@ -0,0 +1,946 @@
|
||||
|
||||
-- *****************************************************************
|
||||
-- Redline AN-50 MIB
|
||||
-- Copyright (c) 2002 by Redline Communications, Inc.
|
||||
-- All rights reserved.
|
||||
-- *****************************************************************
|
||||
|
||||
REDLINE-AN50-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
|
||||
IpAddress, Counter, TimeTicks, enterprises FROM RFC1155-SMI
|
||||
OBJECT-TYPE FROM RFC-1212
|
||||
TRAP-TYPE FROM RFC-1215;
|
||||
|
||||
|
||||
-- ORGANIZATION "Redline Communications, Inc."
|
||||
|
||||
-- postal: Redline Communications Inc.
|
||||
-- 90 Tiverton Court Suite 102
|
||||
-- Markham Ontario L2R 9V2
|
||||
-- Canada
|
||||
-- phone: +1 905 479-8344
|
||||
-- DESCRIPTION "This MIB contains Redline-defined AN-50 attributes."
|
||||
|
||||
-- LAST-UPDATED "200307240930Z"
|
||||
-- Author: Sinisa Djurkic
|
||||
-- DESCRIPTION "New variables for PMP project intoduced."
|
||||
|
||||
-- REVISION "200307110930Z"
|
||||
-- Author: Sinisa Djurkic
|
||||
-- DESCRIPTION "Introduced OIDs for the AN30 application."
|
||||
|
||||
-- REVISION "200301080930Z"
|
||||
-- Author: Sinisa Djurkic
|
||||
-- DESCRIPTION "New AN-50 terminology and new powersupply trap introduced."
|
||||
|
||||
-- REVISION "200212121145Z"
|
||||
-- Author: Sinisa Djurkic
|
||||
-- Appreciation: Aurel Picu, Alex Prvulesku
|
||||
-- DESCRIPTION "Added scalars for front plate and chassis."
|
||||
|
||||
-- REVISION "200211030000Z"
|
||||
-- Author: Sinisa Djurkic
|
||||
-- Appreciation: Aurel Picu
|
||||
-- DESCRIPTION "Added scalars from mib-II interface tree."
|
||||
|
||||
-- REVISION "200210210000Z"
|
||||
-- Author: Sinisa Djurkic
|
||||
-- Appreciation: Aurel Picu, Claude Daniel Ndjouou
|
||||
-- DESCRIPTION "MIB overhauled, complete V1 conversion."
|
||||
|
||||
-- REVISION "200204090000Z"
|
||||
-- Primary Author: Claude Daniel Ndjouou, Ioan Cautil
|
||||
-- DESCRIPTION "Initial version of this MIB module."
|
||||
|
||||
-- REVISION "200308200000Z"
|
||||
-- Author: Bogdan Moldoveanu
|
||||
-- DESCRIPTION "Added an50GenChannelAutoScan and the trap an50ModifiedIDTrap."
|
||||
|
||||
-- REVISION "200401070000Z"
|
||||
-- Author: Bogdan Moldoveanu
|
||||
-- DESCRIPTION "Added an50WrlsDFSAction an50WrlsAntennaGain,an50WrlsATPEnabled and trap an50pmpRegistrationMissed "
|
||||
|
||||
-- REVISION "200401080000Z"
|
||||
-- Author: Bogdan Moldoveanu
|
||||
-- DESCRIPTION "Added trap an50pmpRegistrationSuccessful "
|
||||
|
||||
-- REVISION "200401270000Z"
|
||||
-- Author: Bogdan Moldoveanu
|
||||
-- DESCRIPTION "Added trap an50DFSEvent"
|
||||
|
||||
-- Registration of object identifiers
|
||||
redline OBJECT IDENTIFIER ::= { enterprises 10728 }
|
||||
redlineProducts OBJECT IDENTIFIER ::= { redline 1 }
|
||||
redlineMgmt OBJECT IDENTIFIER ::= { redline 2 }
|
||||
redlineAn50 OBJECT IDENTIFIER ::= { redlineMgmt 16}
|
||||
an50General OBJECT IDENTIFIER ::= { redlineAn50 1 }
|
||||
an50Config OBJECT IDENTIFIER ::= { redlineAn50 2 }
|
||||
an50Pm OBJECT IDENTIFIER ::= { redlineAn50 3 }
|
||||
an50Trap OBJECT IDENTIFIER ::= { redlineAn50 4 }
|
||||
an50LinkPmp OBJECT IDENTIFIER ::= { redlineAn50 5 }
|
||||
|
||||
an50GenUBR OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Indicates the system's current uncoded burst rate. With adaptive modulation enabled, this rate may change over time,
|
||||
depending on the prevailing propagation conditions. "
|
||||
::= { an50General 1 }
|
||||
|
||||
an50GenRFLink OBJECT-TYPE
|
||||
SYNTAX INTEGER { notConnected(1), connected(2) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"connected(2) indicates the terminal is communicating properly to the remote terminal.
|
||||
notConnected(1) indicates there is no communication with the remote terminal."
|
||||
::= { an50General 2 }
|
||||
|
||||
an50GenFrequency OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The frequency which represents the operating channel of the link.
|
||||
The system can be configured to operate over 9 distinct channels."
|
||||
::= { an50General 3 }
|
||||
|
||||
an50GenAllignmentMode OBJECT-TYPE
|
||||
SYNTAX INTEGER { voltage (1), buzzer (2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies if the antenna alignment buzzer is enabled or not."
|
||||
::= { an50General 4 }
|
||||
|
||||
an50GenEncryptionEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER { no (1), yes (2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies if encryption is enabled or not."
|
||||
::= { an50General 5 }
|
||||
|
||||
an50GenFlowControlEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER { no (1), yes (2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This attribute specifies if flow control is enabled or not."
|
||||
::= { an50General 6 }
|
||||
|
||||
an50GenHttpAccessEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER { no (1), yes (2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This attribute specifies if Http Access is enabled or not."
|
||||
::= { an50General 7 }
|
||||
|
||||
an50GenTelnetAccessEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER { no (1), yes (2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This attribute specifies if Telnet Access is enabled or not."
|
||||
::= { an50General 8 }
|
||||
|
||||
an50GenTelnetPort OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This attribute specifies the Telnet port number."
|
||||
::= { an50General 9 }
|
||||
|
||||
an50GenOptionsKey OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This attribute specifies the Product Options Key."
|
||||
::= { an50General 10 }
|
||||
|
||||
an50GenResetDevice OBJECT-TYPE
|
||||
SYNTAX INTEGER { donothing(1), reset(2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
" Resets the AN50 terminal."
|
||||
::= { an50General 11 }
|
||||
|
||||
an50GenFault OBJECT-TYPE
|
||||
SYNTAX INTEGER { off (1), on (2), unknown (3) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The attribute specifies the Fault LED status of the terminal."
|
||||
::= { an50General 12 }
|
||||
|
||||
an50GenTxPower OBJECT-TYPE
|
||||
SYNTAX INTEGER (-20 .. 20)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The actual Tx Power of the AN-50 Node."
|
||||
::= { an50General 13 }
|
||||
|
||||
an50GenRegisteredStations OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The actual number of configured links."
|
||||
::= { an50General 14 }
|
||||
|
||||
an50GenRegisteredConnections OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The actual number of configured connections."
|
||||
::= { an50General 15 }
|
||||
|
||||
an50GenActiveWirelessLinks OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The actual number of provisioned links."
|
||||
::= { an50General 16 }
|
||||
|
||||
an50GenChannelAutoScan OBJECT-TYPE
|
||||
SYNTAX INTEGER { no (1), yes (2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Auto-Scanning feature for the channel."
|
||||
::= { an50General 17 }
|
||||
|
||||
an50GenIduType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Indoor Unit Type."
|
||||
::= { an50General 18 }
|
||||
|
||||
an50GenOduType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Outdoor Unit Type."
|
||||
::= { an50General 19 }
|
||||
|
||||
|
||||
--
|
||||
-- Ethernet Configuration Group
|
||||
--
|
||||
|
||||
an50ConfigEther OBJECT IDENTIFIER ::= { an50Config 1 }
|
||||
|
||||
an50EtherMacAddress OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The Ethernet MAC address of the local terminal."
|
||||
::= { an50ConfigEther 1 }
|
||||
|
||||
an50EtherGateway OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The IP Gateway of the AN-50 This field is used to specify the IP address of the gateway with
|
||||
which the AN-50 is communicating through the core network."
|
||||
::= { an50ConfigEther 2 }
|
||||
|
||||
an50EtherPortStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER { down (1), up (2), unknown (3) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The attribute specifies the status of the Ethernet Port of the AN50."
|
||||
::= { an50ConfigEther 3 }
|
||||
|
||||
an50EtherIP OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The IP address of the AN-50, The default address from the factory
|
||||
is 192.168.25.2. For the initial set-up, the terminal should not
|
||||
be connected to the Internet network, i.e. the host computer should
|
||||
be connected directly to the terminal Ethernet port, to avoid address
|
||||
conflicts with other devices in a public network. Once the IP address has been set,
|
||||
the terminal can be connected to the core network, where it can receive either
|
||||
static or dynamic addressing (DHCP) in future configuration updates."
|
||||
::= { an50ConfigEther 4 }
|
||||
|
||||
an50EtherMask OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The IP Subnet Mask of the AN-50, The value is typically set to 255.255.255.0 (Class C
|
||||
subnet), which prevents certain local devices from going out into the wireless network."
|
||||
::= { an50ConfigEther 5 }
|
||||
|
||||
an50Ether100 OBJECT-TYPE
|
||||
SYNTAX INTEGER { s10Mbs (1), s100Mbs (2), unknown (3) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies the 100 Mb/s Ethernet LED status of the AN50."
|
||||
::= { an50ConfigEther 6 }
|
||||
|
||||
an50EtherFd OBJECT-TYPE
|
||||
SYNTAX INTEGER { halfDuplex (1), fullDuplex (2), unknown (3) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The attribute specifies the Ethernet FD LED status of the AN50."
|
||||
::= { an50ConfigEther 7 }
|
||||
|
||||
--
|
||||
-- Wireless Configuration Group
|
||||
--
|
||||
|
||||
an50ConfigWireless OBJECT IDENTIFIER ::= { an50Config 2 }
|
||||
|
||||
an50WrlsChannel OBJECT-TYPE
|
||||
SYNTAX INTEGER { chan1 (1), chan1A (2), chan2 (3), chan2A (4),
|
||||
chan3 (5), chan3A (6), chan4 (7), chan4A (8), chan5 (9) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"specifies the operating channel of the system, within the 100
|
||||
MHz available in the 5.8GHz UNII band.
|
||||
To avoid interference, two PTP links operating in the same physical
|
||||
location (co-located) or within close proximity (e.g. across the street) must
|
||||
be separated by at least one channel, i.e. the gap between channels should
|
||||
be 20 MHz or more (e.g. channels 1 and 3)."
|
||||
::= { an50ConfigWireless 1 }
|
||||
|
||||
an50WrlsTxPower OBJECT-TYPE
|
||||
SYNTAX INTEGER (-20 .. 20)
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The Tx Power of the AN-50. Specifies the power level of the system, which is
|
||||
preset at the factory and should not be altered. In the event that this
|
||||
parameter needs to be changed, please contact the Redline support team."
|
||||
::= { an50ConfigWireless 2 }
|
||||
|
||||
an50WrlsModReduction OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..7)
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The Modulation Reduction Level of the AN-50. Applies when the Adaptive rate is disabled.
|
||||
Specifies how many levels the system must drop in modulation before
|
||||
beginning re-transmission to address packet errors.
|
||||
The value can be set from 1-7, with 2 being the typical value."
|
||||
::= { an50ConfigWireless 3 }
|
||||
|
||||
an50WrlsAdaptiveMod OBJECT-TYPE
|
||||
SYNTAX INTEGER { notAdaptiveRate(1), adaptiveRate(2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Setting this attribute to AdaptiveRate(2) sets the system to operate in adaptive
|
||||
modulation mode. It is recommended to keep the AN-50 in this mode so
|
||||
that the system can automatically adjust the modulation level to the
|
||||
highest possible data rate based on measured RF performance. The user
|
||||
can define the minimum desired modulation level by setting the Main rate
|
||||
parameter.
|
||||
If the system meets this data rate, then the Signal LED on the front
|
||||
panel will light continuously green. If packet errors exceed one out of a million,
|
||||
the system will automatically lower the modulation level to maintain the link.
|
||||
In this case, the LED will flash green.
|
||||
If errors continue when the system reaches the lowest modulation level,
|
||||
the LED will flash red to indicate a failed RF link.
|
||||
The user can also disable the dynamic modulation mode by disabling
|
||||
Adaptive Modulation. In this mode, the user is required to set the Burst Rate and the Modulation
|
||||
Reduction Level. It is recommended not to operate the system in manual mode, as this mode
|
||||
is intended primarily for field support.
|
||||
Note the Signal LED will light solid green when the packet error rate is
|
||||
less than 1 out of a million. When the errors exceed this limit, the LED
|
||||
will not illuminate, indicating the RF link has failed."
|
||||
::= { an50ConfigWireless 4 }
|
||||
|
||||
an50WrlsUBR OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..7)
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Set uncoded burst rate in steps (0=6Mb/s,1=9Mb/s,2=12Mb/s,3=18Mb/s,4=24Mb/s,5=36Mb/s,6=48Mb/s,7=54Mbs).
|
||||
Defines the desired net uncoded burst rate for the link."
|
||||
::= { an50ConfigWireless 5 }
|
||||
|
||||
an50WrlsMaster OBJECT-TYPE
|
||||
SYNTAX INTEGER { ptpSlave(1), ptpMaster(2),pmpSlave(3), pmpMaster(4) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"1 = PMP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master"
|
||||
::= { an50ConfigWireless 6 }
|
||||
|
||||
an50WrlsVersion OBJECT-TYPE
|
||||
SYNTAX INTEGER { firstFlash(1), secondFlash(2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Sets the version of the AN50 system software.
|
||||
Software can be remotely downloaded into the AN50. The system
|
||||
comprises sufficient memory to hold two independent software loads.
|
||||
The operator can specify which load to set as the active version."
|
||||
::= { an50ConfigWireless 7 }
|
||||
|
||||
an50WrlsEncryptCode OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The Encryption Key used for the AN-50. Enter the MAC address of the remote terminal
|
||||
to enable over-the-air data encryption."
|
||||
::= { an50ConfigWireless 8 }
|
||||
|
||||
an50WrlsCableAttenuation OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The Cable Attenuation for the AN-50"
|
||||
::= { an50ConfigWireless 9 }
|
||||
|
||||
an50WrlsRfPortStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER { down (1), up (2), unknown (3)}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The attribute specifies the status of the AN50s Wireless Port."
|
||||
::= { an50ConfigWireless 10 }
|
||||
|
||||
an50WrlsSaveConfig OBJECT-TYPE
|
||||
SYNTAX INTEGER { donothing(1), saveCofig(2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The attribute saves the entire config set of the AN50."
|
||||
::= { an50ConfigWireless 11 }
|
||||
|
||||
an50WrlsActivateConfig OBJECT-TYPE
|
||||
SYNTAX INTEGER { donothing(1), activeCofig(2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The attribute activates the entire config set of the AN50."
|
||||
::= { an50ConfigWireless 12 }
|
||||
|
||||
an50WrlsRadioEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER { txOff (1), txOn (2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Radio Enable specifies whether radio transmission is enabled or disabled."
|
||||
::= { an50ConfigWireless 13 }
|
||||
|
||||
an50WrlsRfStatusErrorCode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies the Error Code for the RF Status."
|
||||
::= { an50ConfigWireless 14 }
|
||||
|
||||
an50WrlsRfSignal OBJECT-TYPE
|
||||
SYNTAX INTEGER { off (1), on (2), blinking(3) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies the Wireless Signal LED status."
|
||||
::= { an50ConfigWireless 15 }
|
||||
|
||||
|
||||
an50WrlsLLMode OBJECT-TYPE
|
||||
SYNTAX INTEGER { auto (1), manual (2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Manual Link Length Mode."
|
||||
::= { an50ConfigWireless 16 }
|
||||
|
||||
an50WrlsLMU OBJECT-TYPE
|
||||
SYNTAX INTEGER { mile (1), km (2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Link Measurements Units (mile / Km)."
|
||||
::= { an50ConfigWireless 17 }
|
||||
|
||||
an50WrlsLL OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Link Length."
|
||||
::= { an50ConfigWireless 18 }
|
||||
|
||||
|
||||
an50ConfigScheduler OBJECT IDENTIFIER ::= { an50ConfigWireless 19 }
|
||||
|
||||
an50WrlsFrameSize OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies the size of wireless frame (DL+RTD+UL)in micro seconds."
|
||||
::= { an50ConfigScheduler 1 }
|
||||
|
||||
an50WrlsMinBlockSize OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies a minimum number of bytes compising transmitted block."
|
||||
::= { an50ConfigScheduler 2 }
|
||||
|
||||
an50WrlsDownlinkSize OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies the size of downlink sub-frame in micro seconds."
|
||||
::= { an50ConfigScheduler 3 }
|
||||
|
||||
an50WrlsRoundTripDelay OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specifies the round trip delay in micro seconds."
|
||||
::= { an50ConfigScheduler 4 }
|
||||
|
||||
an50WrlsAdaptiveDLSize OBJECT-TYPE
|
||||
SYNTAX INTEGER { off (1), on (2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Enables or desables adaptive downlink size."
|
||||
::= { an50ConfigScheduler 5 }
|
||||
|
||||
an50WrlsExtSyncronize OBJECT-TYPE
|
||||
SYNTAX INTEGER { off (1), on (2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Enables or desables external synchronization."
|
||||
::= { an50ConfigScheduler 6 }
|
||||
|
||||
an50WrlsMaximumDistance OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..100)
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Maximum distance between basestation and subscriber station in km."
|
||||
::= { an50ConfigScheduler 7 }
|
||||
|
||||
an50WrlsRegistrationPeriod OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..100)
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Number of frames between registration periods."
|
||||
::= { an50ConfigScheduler 8 }
|
||||
|
||||
|
||||
--
|
||||
-- Config Default Group
|
||||
--
|
||||
an50ConfigDefGroup OBJECT IDENTIFIER ::= { an50ConfigWireless 20 }
|
||||
an50WrlsBroadcastDLCIR OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Broadcast DL CIR in kbps."
|
||||
::= { an50ConfigDefGroup 1 }
|
||||
|
||||
an50WrlsBroadcastDLPIR OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Broadcast Dl PIR in kbps."
|
||||
::= { an50ConfigDefGroup 2 }
|
||||
|
||||
an50WrlsDFSAction OBJECT-TYPE
|
||||
SYNTAX INTEGER { none (1), txDisabled(2), changeFreq(3)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Action taken when another system is detected on the same frequency"
|
||||
::= { an50ConfigWireless 21 }
|
||||
|
||||
an50WrlsAntennaGain OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Antenna Gain"
|
||||
::= { an50ConfigWireless 22 }
|
||||
|
||||
an50WrlsATPEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER { no (1), yes(2)}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Automatic Transmitted Power Control Enable"
|
||||
::= { an50ConfigWireless 23 }
|
||||
|
||||
|
||||
--
|
||||
-- Performance Data Group
|
||||
--
|
||||
|
||||
an50ResetStatistics OBJECT-TYPE
|
||||
SYNTAX INTEGER { donothing(1), reset(2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A value of reset(2) resets the performance statistics on the AN-50
|
||||
a value of donothing(1) does nothing."
|
||||
::= { an50Pm 1 }
|
||||
--
|
||||
-- Ethernet Performance Data Group
|
||||
--
|
||||
an50PmEther OBJECT IDENTIFIER ::= { an50Pm 2 }
|
||||
|
||||
an50PmEtherRxPackets OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Counts the number of packets successfully received by the local system."
|
||||
::= { an50PmEther 1 }
|
||||
|
||||
an50PmEtherRxPacketsErr OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Counts the number of packet errors received by the local system."
|
||||
::= { an50PmEther 2 }
|
||||
|
||||
an50PmEtherTxPackets OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Counts the number of Ethernet packets transmitted by the local system."
|
||||
::= { an50PmEther 3 }
|
||||
|
||||
an50PmEtherTxPacketsErr OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Counts the number of Ethernet errors packets transmitted by the local system."
|
||||
::= { an50PmEther 4 }
|
||||
|
||||
an50PmEtherRxPacketsDisc OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Counts the number of packets discarded by receiver."
|
||||
::= { an50PmEther 5 }
|
||||
|
||||
an50PmEtherTxPacketsDisc OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Counts the number of packets discarded by transmitter."
|
||||
::= { an50PmEther 6 }
|
||||
|
||||
|
||||
--
|
||||
-- Wireless Performance Data Group
|
||||
--
|
||||
an50PmWrls OBJECT IDENTIFIER ::= { an50Pm 3 }
|
||||
|
||||
an50PmWrlsRxSigMin OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Indicates the minimum received signal strength measured since the last SNMP update."
|
||||
::= { an50PmWrls 1 }
|
||||
|
||||
an50PmWrlsRxSigMean OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Indicates the average received signal strength measured since the last SNMP update."
|
||||
::= { an50PmWrls 2 }
|
||||
|
||||
an50PmWrlsRxSigMax OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Indicates the maximum received signal strength measured since the last SNMP update"
|
||||
::= { an50PmWrls 3 }
|
||||
|
||||
an50PmWrlsAvgSinAdr OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Indicates the average signal to noise ratio measured since the last SNMP update.
|
||||
The ratio is based on the digital information provided from the output of the AtoD converter."
|
||||
::= { an50PmWrls 4 }
|
||||
|
||||
an50PmWrlsRxPackets OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
" Indicates the number of packets received over the air from the remote terminal."
|
||||
::= { an50PmWrls 5 }
|
||||
|
||||
an50PmWrlsRxPacketsRetx OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Indicates the number of packets retransmitted over the air from the remoter terminal."
|
||||
::= { an50PmWrls 6 }
|
||||
|
||||
an50PmWrlsRxPacketsDisc OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
" Indicates the number of packets, originating from the remote terminal
|
||||
that were lost over the air due to degradation in the RF link."
|
||||
::= { an50PmWrls 7 }
|
||||
|
||||
an50PmWrlsTxPackets OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
" Indicates the number of wireless packets (including Ethernet frames
|
||||
and error correction bytes) transmitted over the air by the local terminal."
|
||||
::= { an50PmWrls 8}
|
||||
|
||||
an50PmWrlsTxPacketsRetx OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Indicates the number of packets retransmitted
|
||||
over the air by the local terminal. The retransmission scheme is based on
|
||||
the Acknowledge/Request (ARQ) algorithm that detects when packets are
|
||||
lost and makes a request to the MAC scheduler to repeat transmission of
|
||||
the lost packets."
|
||||
::= { an50PmWrls 9}
|
||||
|
||||
an50PmWrlsTxPacketsDisc OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Indicates the total number of packets lost over the air due to degradation
|
||||
in the RF link."
|
||||
::= { an50PmWrls 10}
|
||||
|
||||
an50PmWrlsCalcDst OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The calculated link distance."
|
||||
::= { an50PmWrls 11}
|
||||
|
||||
--
|
||||
-- Software Upgrade Group
|
||||
--
|
||||
|
||||
an50Sw OBJECT IDENTIFIER ::= { an50Config 3 }
|
||||
|
||||
an50SwServer OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The address of the TFTP server used for software upgrades.
|
||||
If the TFTP server is unknown, return 0.0.0.0."
|
||||
::= { an50Sw 1 }
|
||||
|
||||
an50SwFilename OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..32))
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The file name of the software image to be loaded into this device."
|
||||
::= { an50Sw 2 }
|
||||
|
||||
an50SwAdminStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER { noUpgrade(1), upgrade(2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"If set to upgrade(2), the device will initiate a
|
||||
TFTP software image download using an50SwFilename.
|
||||
If the download process is interrupted by a reset or
|
||||
power failure, the device will load the previous image.
|
||||
If set to noUpgrade(1), the device will
|
||||
revert to the previous version of the software.
|
||||
At initial startup, this object has the default value of
|
||||
noUpgrade(1)."
|
||||
::= { an50Sw 3 }
|
||||
|
||||
an50SwOperStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER { inProgress(1), completeSuccess(2), failed(3), other(4) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "InProgress(1) indicates that a TFTP download is underway,
|
||||
completeSuccess(2) indicates that the last software upgrade was successful,
|
||||
failed(3) indicates that the last attempted download
|
||||
failed, ordinarily due to TFTP timeout."
|
||||
::= { an50Sw 4 }
|
||||
|
||||
an50SwCurrentVers OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The software version currently operating in this device's flash.
|
||||
This object should be in the syntax used by the individual
|
||||
vendor to identify software versions. If it is not applicable,
|
||||
this MUST contain an empty string."
|
||||
::= { an50Sw 5 }
|
||||
|
||||
an50SwOtherVers OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "The software version in the secondary flash.
|
||||
This object should be in the syntax used by the individual
|
||||
vendor to identify software versions. If it is not applicable,
|
||||
this MUST contain an empty string."
|
||||
::= { an50Sw 6 }
|
||||
|
||||
--
|
||||
-- Traps Group.
|
||||
--
|
||||
|
||||
an50SysLastTrapTime OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The value of system.sysUpTime when the last trap was generated. If no traps
|
||||
have been generated since the last reset, this attribute has a value of 0.
|
||||
No trap is issued as a result of a change to this value."
|
||||
::= { an50Trap 1 }
|
||||
|
||||
|
||||
an50TftpFailTrap TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50SwServer,
|
||||
an50SwFilename,
|
||||
an50SwAdminStatus,
|
||||
an50SwOperStatus,
|
||||
an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the failure of a Software Download."
|
||||
::= 1
|
||||
|
||||
an50TftpSuccessTrap TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50SwServer,
|
||||
an50SwFilename,
|
||||
an50SwAdminStatus,
|
||||
an50SwOperStatus,
|
||||
an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the success of a Software Download."
|
||||
::= 2
|
||||
|
||||
an50PswdChangeFailTrap TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the failure of a password change."
|
||||
::= 3
|
||||
|
||||
an50FirmwareConfigFailTrap TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the failure of a firmware config."
|
||||
::= 4
|
||||
|
||||
an50EepromCorruptedTrap TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the corruption of the EEPROM."
|
||||
::= 5
|
||||
|
||||
an50PowerSupplyFailureTrap TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the power supply failure."
|
||||
::= 6
|
||||
|
||||
an50SaveConfigTrap TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the saving of configuration"
|
||||
::= 7
|
||||
|
||||
an50ModifiedIDTrap TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50pmpLastModifiedCID,
|
||||
an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the modification in the configuration of a CID"
|
||||
::= 8
|
||||
|
||||
an50pmpRegistrationMissed TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50pmpLastMissedSsMacAddress,
|
||||
an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the missing of the registration by a AN50 Subscriber to one BS.This trap is sent by the BS and contains the MAC address of the SS missing the registration"
|
||||
::= 9
|
||||
|
||||
an50pmpRegistrationSuccessful TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50pmpLastRegisteredSsMacAddress,
|
||||
an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report the successful registration of an AN50 Subscriber to BS.This trap is sent by the BS and contains the MAC address of the newly registered SS"
|
||||
::= 10
|
||||
|
||||
an50DFSEvent TRAP-TYPE
|
||||
ENTERPRISE redline
|
||||
VARIABLES { an50SysLastTrapTime }
|
||||
DESCRIPTION "An event to report a DFS event in AN50"
|
||||
::= 11
|
||||
|
||||
an50MaxCid OBJECT-TYPE
|
||||
SYNTAX INTEGER (1 .. 1024)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "The maximum number of CID for this equipment"
|
||||
::= { an50LinkPmp 1 }
|
||||
|
||||
an50LinkCurrentAvailId OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "The maximum number of CID for this equipment"
|
||||
::= { an50LinkPmp 2 }
|
||||
|
||||
END
|
Loading…
x
Reference in New Issue
Block a user