-- Redline AN-50 MIB
-- Copyright (c) 2002 by Redline Communications, Inc.
-- All rights reserved.
-- *****************************************************************
REDLINE-AN50-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Counter, TimeTicks, enterprises FROM RFC1155-SMI
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215;
-- ORGANIZATION "Redline Communications, Inc."
-- postal: Redline Communications Inc.
-- 90 Tiverton Court Suite 102
-- Markham Ontario L2R 9V2
-- Canada
-- phone: +1 905 479-8344
-- DESCRIPTION "This MIB contains Redline-defined AN-50 attributes."
-- LAST-UPDATED "200307240930Z"
-- Author: Sinisa Djurkic
-- DESCRIPTION "New variables for PMP project intoduced."
-- REVISION "200307110930Z"
-- Author: Sinisa Djurkic
-- DESCRIPTION "Introduced OIDs for the AN30 application."
-- REVISION "200301080930Z"
-- Author: Sinisa Djurkic
-- DESCRIPTION "New AN-50 terminology and new powersupply trap introduced."
-- REVISION "200212121145Z"
-- Author: Sinisa Djurkic
-- Appreciation: Aurel Picu, Alex Prvulesku
-- DESCRIPTION "Added scalars for front plate and chassis."
-- REVISION "200211030000Z"
-- Author: Sinisa Djurkic
-- Appreciation: Aurel Picu
-- DESCRIPTION "Added scalars from mib-II interface tree."
-- REVISION "200210210000Z"
-- Author: Sinisa Djurkic
-- Appreciation: Aurel Picu, Claude Daniel Ndjouou
-- DESCRIPTION "MIB overhauled, complete V1 conversion."
-- REVISION "200204090000Z"
-- Primary Author: Claude Daniel Ndjouou, Ioan Cautil
-- DESCRIPTION "Initial version of this MIB module."
-- REVISION "200308200000Z"
-- Author: Bogdan Moldoveanu
-- DESCRIPTION "Added an50GenChannelAutoScan and the trap an50ModifiedIDTrap."
-- REVISION "200401070000Z"
-- Author: Bogdan Moldoveanu
-- DESCRIPTION "Added an50WrlsDFSAction an50WrlsAntennaGain,an50WrlsATPEnabled and trap an50pmpRegistrationMissed "
-- REVISION "200401080000Z"
-- Author: Bogdan Moldoveanu
-- DESCRIPTION "Added trap an50pmpRegistrationSuccessful "
-- REVISION "200401270000Z"
-- Author: Bogdan Moldoveanu
-- DESCRIPTION "Added trap an50DFSEvent"
-- Registration of object identifiers
redline OBJECT IDENTIFIER ::= { enterprises 10728 }
redlineProducts OBJECT IDENTIFIER ::= { redline 1 }
redlineMgmt OBJECT IDENTIFIER ::= { redline 2 }
redlineAn50 OBJECT IDENTIFIER ::= { redlineMgmt 16}
an50General OBJECT IDENTIFIER ::= { redlineAn50 1 }
an50Config OBJECT IDENTIFIER ::= { redlineAn50 2 }
an50Pm OBJECT IDENTIFIER ::= { redlineAn50 3 }
an50Trap OBJECT IDENTIFIER ::= { redlineAn50 4 }
an50LinkPmp OBJECT IDENTIFIER ::= { redlineAn50 5 }
an50GenUBR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the system's current uncoded burst rate. With adaptive modulation enabled, this rate may change over time,
depending on the prevailing propagation conditions. "
::= { an50General 1 }
an50GenRFLink OBJECT-TYPE
SYNTAX INTEGER { notConnected(1), connected(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"connected(2) indicates the terminal is communicating properly to the remote terminal.
notConnected(1) indicates there is no communication with the remote terminal."
::= { an50General 2 }
an50GenFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The frequency which represents the operating channel of the link.
The system can be configured to operate over 9 distinct channels."
::= { an50General 3 }
an50GenAllignmentMode OBJECT-TYPE
SYNTAX INTEGER { voltage (1), buzzer (2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies if the antenna alignment buzzer is enabled or not."
::= { an50General 4 }
an50GenEncryptionEnabled OBJECT-TYPE
SYNTAX INTEGER { no (1), yes (2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies if encryption is enabled or not."
::= { an50General 5 }
an50GenFlowControlEnabled OBJECT-TYPE
SYNTAX INTEGER { no (1), yes (2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies if flow control is enabled or not."
::= { an50General 6 }
an50GenHttpAccessEnabled OBJECT-TYPE
SYNTAX INTEGER { no (1), yes (2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies if Http Access is enabled or not."
::= { an50General 7 }
an50GenTelnetAccessEnabled OBJECT-TYPE
SYNTAX INTEGER { no (1), yes (2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies if Telnet Access is enabled or not."
::= { an50General 8 }
an50GenTelnetPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the Telnet port number."
::= { an50General 9 }
an50GenOptionsKey OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the Product Options Key."
::= { an50General 10 }
an50GenResetDevice OBJECT-TYPE
SYNTAX INTEGER { donothing(1), reset(2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Resets the AN50 terminal."
::= { an50General 11 }
an50GenFault OBJECT-TYPE
SYNTAX INTEGER { off (1), on (2), unknown (3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The attribute specifies the Fault LED status of the terminal."
::= { an50General 12 }
an50GenTxPower OBJECT-TYPE
SYNTAX INTEGER (-20 .. 20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The actual Tx Power of the AN-50 Node."
::= { an50General 13 }
an50GenRegisteredStations OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The actual number of configured links."
::= { an50General 14 }
an50GenRegisteredConnections OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The actual number of configured connections."
::= { an50General 15 }
an50GenActiveWirelessLinks OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The actual number of provisioned links."
::= { an50General 16 }
an50GenChannelAutoScan OBJECT-TYPE
SYNTAX INTEGER { no (1), yes (2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Auto-Scanning feature for the channel."
::= { an50General 17 }
an50GenIduType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indoor Unit Type."
::= { an50General 18 }
an50GenOduType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Outdoor Unit Type."
::= { an50General 19 }
--
-- Ethernet Configuration Group
--
an50ConfigEther OBJECT IDENTIFIER ::= { an50Config 1 }
an50EtherMacAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Ethernet MAC address of the local terminal."
::= { an50ConfigEther 1 }
an50EtherGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Gateway of the AN-50 This field is used to specify the IP address of the gateway with
which the AN-50 is communicating through the core network."
::= { an50ConfigEther 2 }
an50EtherPortStatus OBJECT-TYPE
SYNTAX INTEGER { down (1), up (2), unknown (3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The attribute specifies the status of the Ethernet Port of the AN50."
::= { an50ConfigEther 3 }
an50EtherIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the AN-50, The default address from the factory
is 192.168.25.2. For the initial set-up, the terminal should not
be connected to the Internet network, i.e. the host computer should
be connected directly to the terminal Ethernet port, to avoid address
conflicts with other devices in a public network. Once the IP address has been set,
the terminal can be connected to the core network, where it can receive either
static or dynamic addressing (DHCP) in future configuration updates."
::= { an50ConfigEther 4 }
an50EtherMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Subnet Mask of the AN-50, The value is typically set to 255.255.255.0 (Class C
subnet), which prevents certain local devices from going out into the wireless network."
::= { an50ConfigEther 5 }
an50Ether100 OBJECT-TYPE
SYNTAX INTEGER { s10Mbs (1), s100Mbs (2), unknown (3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the 100 Mb/s Ethernet LED status of the AN50."
::= { an50ConfigEther 6 }
an50EtherFd OBJECT-TYPE
SYNTAX INTEGER { halfDuplex (1), fullDuplex (2), unknown (3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The attribute specifies the Ethernet FD LED status of the AN50."
::= { an50ConfigEther 7 }
--
-- Wireless Configuration Group
--
an50ConfigWireless OBJECT IDENTIFIER ::= { an50Config 2 }
an50WrlsChannel OBJECT-TYPE
SYNTAX INTEGER { chan1 (1), chan1A (2), chan2 (3), chan2A (4),
chan3 (5), chan3A (6), chan4 (7), chan4A (8), chan5 (9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"specifies the operating channel of the system, within the 100
MHz available in the 5.8GHz UNII band.
To avoid interference, two PTP links operating in the same physical
location (co-located) or within close proximity (e.g. across the street) must
be separated by at least one channel, i.e. the gap between channels should
be 20 MHz or more (e.g. channels 1 and 3)."
::= { an50ConfigWireless 1 }
an50WrlsTxPower OBJECT-TYPE
SYNTAX INTEGER (-20 .. 20)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Tx Power of the AN-50. Specifies the power level of the system, which is
preset at the factory and should not be altered. In the event that this
parameter needs to be changed, please contact the Redline support team."
::= { an50ConfigWireless 2 }
an50WrlsModReduction OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Modulation Reduction Level of the AN-50. Applies when the Adaptive rate is disabled.
Specifies how many levels the system must drop in modulation before
beginning re-transmission to address packet errors.
The value can be set from 1-7, with 2 being the typical value."
::= { an50ConfigWireless 3 }
an50WrlsAdaptiveMod OBJECT-TYPE
SYNTAX INTEGER { notAdaptiveRate(1), adaptiveRate(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Setting this attribute to AdaptiveRate(2) sets the system to operate in adaptive
modulation mode. It is recommended to keep the AN-50 in this mode so
that the system can automatically adjust the modulation level to the
highest possible data rate based on measured RF performance. The user
can define the minimum desired modulation level by setting the Main rate
parameter.
If the system meets this data rate, then the Signal LED on the front
panel will light continuously green. If packet errors exceed one out of a million,
the system will automatically lower the modulation level to maintain the link.
In this case, the LED will flash green.
If errors continue when the system reaches the lowest modulation level,
the LED will flash red to indicate a failed RF link.
The user can also disable the dynamic modulation mode by disabling
Adaptive Modulation. In this mode, the user is required to set the Burst Rate and the Modulation
Reduction Level. It is recommended not to operate the system in manual mode, as this mode
is intended primarily for field support.
Note the Signal LED will light solid green when the packet error rate is
less than 1 out of a million. When the errors exceed this limit, the LED
will not illuminate, indicating the RF link has failed."
::= { an50ConfigWireless 4 }
an50WrlsUBR OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set uncoded burst rate in steps (0=6Mb/s,1=9Mb/s,2=12Mb/s,3=18Mb/s,4=24Mb/s,5=36Mb/s,6=48Mb/s,7=54Mbs).
Defines the desired net uncoded burst rate for the link."
::= { an50ConfigWireless 5 }
an50WrlsMaster OBJECT-TYPE
SYNTAX INTEGER { ptpSlave(1), ptpMaster(2),pmpSlave(3), pmpMaster(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"1 = PMP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master"
::= { an50ConfigWireless 6 }
an50WrlsVersion OBJECT-TYPE
SYNTAX INTEGER { firstFlash(1), secondFlash(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Sets the version of the AN50 system software.
Software can be remotely downloaded into the AN50. The system
comprises sufficient memory to hold two independent software loads.
The operator can specify which load to set as the active version."
::= { an50ConfigWireless 7 }
an50WrlsEncryptCode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Encryption Key used for the AN-50. Enter the MAC address of the remote terminal
to enable over-the-air data encryption."
::= { an50ConfigWireless 8 }
an50WrlsCableAttenuation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Cable Attenuation for the AN-50"
::= { an50ConfigWireless 9 }
an50WrlsRfPortStatus OBJECT-TYPE
SYNTAX INTEGER { down (1), up (2), unknown (3)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The attribute specifies the status of the AN50s Wireless Port."
::= { an50ConfigWireless 10 }
an50WrlsSaveConfig OBJECT-TYPE
SYNTAX INTEGER { donothing(1), saveCofig(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The attribute saves the entire config set of the AN50."
::= { an50ConfigWireless 11 }
an50WrlsActivateConfig OBJECT-TYPE
SYNTAX INTEGER { donothing(1), activeCofig(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The attribute activates the entire config set of the AN50."
::= { an50ConfigWireless 12 }
an50WrlsRadioEnable OBJECT-TYPE
SYNTAX INTEGER { txOff (1), txOn (2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radio Enable specifies whether radio transmission is enabled or disabled."
::= { an50ConfigWireless 13 }
an50WrlsRfStatusErrorCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the Error Code for the RF Status."
::= { an50ConfigWireless 14 }
an50WrlsRfSignal OBJECT-TYPE
SYNTAX INTEGER { off (1), on (2), blinking(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the Wireless Signal LED status."
::= { an50ConfigWireless 15 }
an50WrlsLLMode OBJECT-TYPE
SYNTAX INTEGER { auto (1), manual (2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manual Link Length Mode."
::= { an50ConfigWireless 16 }
an50WrlsLMU OBJECT-TYPE
SYNTAX INTEGER { mile (1), km (2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link Measurements Units (mile / Km)."
::= { an50ConfigWireless 17 }
an50WrlsLL OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link Length."
::= { an50ConfigWireless 18 }
an50ConfigScheduler OBJECT IDENTIFIER ::= { an50ConfigWireless 19 }
an50WrlsFrameSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the size of wireless frame (DL+RTD+UL)in micro seconds."
::= { an50ConfigScheduler 1 }
an50WrlsMinBlockSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies a minimum number of bytes compising transmitted block."
::= { an50ConfigScheduler 2 }
an50WrlsDownlinkSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the size of downlink sub-frame in micro seconds."
::= { an50ConfigScheduler 3 }
an50WrlsRoundTripDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the round trip delay in micro seconds."
::= { an50ConfigScheduler 4 }
an50WrlsAdaptiveDLSize OBJECT-TYPE
SYNTAX INTEGER { off (1), on (2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or desables adaptive downlink size."
::= { an50ConfigScheduler 5 }
an50WrlsExtSyncronize OBJECT-TYPE
SYNTAX INTEGER { off (1), on (2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or desables external synchronization."
::= { an50ConfigScheduler 6 }
an50WrlsMaximumDistance OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum distance between basestation and subscriber station in km."
::= { an50ConfigScheduler 7 }
an50WrlsRegistrationPeriod OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of frames between registration periods."
::= { an50ConfigScheduler 8 }
--
-- Config Default Group
--
an50ConfigDefGroup OBJECT IDENTIFIER ::= { an50ConfigWireless 20 }
an50WrlsBroadcastDLCIR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Broadcast DL CIR in kbps."
::= { an50ConfigDefGroup 1 }
an50WrlsBroadcastDLPIR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Broadcast Dl PIR in kbps."
::= { an50ConfigDefGroup 2 }
an50WrlsDFSAction OBJECT-TYPE
SYNTAX INTEGER { none (1), txDisabled(2), changeFreq(3)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action taken when another system is detected on the same frequency"
::= { an50ConfigWireless 21 }
an50WrlsAntennaGain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Antenna Gain"
::= { an50ConfigWireless 22 }
an50WrlsATPEnabled OBJECT-TYPE
SYNTAX INTEGER { no (1), yes(2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Automatic Transmitted Power Control Enable"
::= { an50ConfigWireless 23 }
--
-- Performance Data Group
--
an50ResetStatistics OBJECT-TYPE
SYNTAX INTEGER { donothing(1), reset(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A value of reset(2) resets the performance statistics on the AN-50
a value of donothing(1) does nothing."
::= { an50Pm 1 }
--
-- Ethernet Performance Data Group
--
an50PmEther OBJECT IDENTIFIER ::= { an50Pm 2 }
an50PmEtherRxPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Counts the number of packets successfully received by the local system."
::= { an50PmEther 1 }
an50PmEtherRxPacketsErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Counts the number of packet errors received by the local system."
::= { an50PmEther 2 }
an50PmEtherTxPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Counts the number of Ethernet packets transmitted by the local system."
::= { an50PmEther 3 }
an50PmEtherTxPacketsErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Counts the number of Ethernet errors packets transmitted by the local system."
::= { an50PmEther 4 }
an50PmEtherRxPacketsDisc OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Counts the number of packets discarded by receiver."
::= { an50PmEther 5 }
an50PmEtherTxPacketsDisc OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Counts the number of packets discarded by transmitter."
::= { an50PmEther 6 }
--
-- Wireless Performance Data Group
--
an50PmWrls OBJECT IDENTIFIER ::= { an50Pm 3 }
an50PmWrlsRxSigMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the minimum received signal strength measured since the last SNMP update."
::= { an50PmWrls 1 }
an50PmWrlsRxSigMean OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the average received signal strength measured since the last SNMP update."
::= { an50PmWrls 2 }
an50PmWrlsRxSigMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum received signal strength measured since the last SNMP update"
::= { an50PmWrls 3 }
an50PmWrlsAvgSinAdr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the average signal to noise ratio measured since the last SNMP update.
The ratio is based on the digital information provided from the output of the AtoD converter."
::= { an50PmWrls 4 }
an50PmWrlsRxPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Indicates the number of packets received over the air from the remote terminal."
::= { an50PmWrls 5 }
an50PmWrlsRxPacketsRetx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the number of packets retransmitted over the air from the remoter terminal."
::= { an50PmWrls 6 }
an50PmWrlsRxPacketsDisc OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Indicates the number of packets, originating from the remote terminal
that were lost over the air due to degradation in the RF link."
::= { an50PmWrls 7 }
an50PmWrlsTxPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Indicates the number of wireless packets (including Ethernet frames
and error correction bytes) transmitted over the air by the local terminal."
::= { an50PmWrls 8}
an50PmWrlsTxPacketsRetx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the number of packets retransmitted
over the air by the local terminal. The retransmission scheme is based on
the Acknowledge/Request (ARQ) algorithm that detects when packets are
lost and makes a request to the MAC scheduler to repeat transmission of
the lost packets."
::= { an50PmWrls 9}
an50PmWrlsTxPacketsDisc OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of packets lost over the air due to degradation
in the RF link."
::= { an50PmWrls 10}
an50PmWrlsCalcDst OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The calculated link distance."
::= { an50PmWrls 11}
--
-- Software Upgrade Group
--
an50Sw OBJECT IDENTIFIER ::= { an50Config 3 }
an50SwServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The address of the TFTP server used for software upgrades.
If the TFTP server is unknown, return 0.0.0.0."
::= { an50Sw 1 }
an50SwFilename OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The file name of the software image to be loaded into this device."
::= { an50Sw 2 }
an50SwAdminStatus OBJECT-TYPE
SYNTAX INTEGER { noUpgrade(1), upgrade(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If set to upgrade(2), the device will initiate a
TFTP software image download using an50SwFilename.
If the download process is interrupted by a reset or
power failure, the device will load the previous image.
If set to noUpgrade(1), the device will
revert to the previous version of the software.
At initial startup, this object has the default value of
noUpgrade(1)."
::= { an50Sw 3 }
an50SwOperStatus OBJECT-TYPE
SYNTAX INTEGER { inProgress(1), completeSuccess(2), failed(3), other(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "InProgress(1) indicates that a TFTP download is underway,
completeSuccess(2) indicates that the last software upgrade was successful,
failed(3) indicates that the last attempted download
failed, ordinarily due to TFTP timeout."
::= { an50Sw 4 }
an50SwCurrentVers OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The software version currently operating in this device's flash.
This object should be in the syntax used by the individual
vendor to identify software versions. If it is not applicable,
this MUST contain an empty string."
::= { an50Sw 5 }
an50SwOtherVers OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "The software version in the secondary flash.
This object should be in the syntax used by the individual
vendor to identify software versions. If it is not applicable,
this MUST contain an empty string."
::= { an50Sw 6 }
--
-- Traps Group.
--
an50SysLastTrapTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of system.sysUpTime when the last trap was generated. If no traps
have been generated since the last reset, this attribute has a value of 0.
No trap is issued as a result of a change to this value."
::= { an50Trap 1 }
an50TftpFailTrap TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50SwServer,
an50SwFilename,
an50SwAdminStatus,
an50SwOperStatus,
an50SysLastTrapTime }
DESCRIPTION "An event to report the failure of a Software Download."
::= 1
an50TftpSuccessTrap TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50SwServer,
an50SwFilename,
an50SwAdminStatus,
an50SwOperStatus,
an50SysLastTrapTime }
DESCRIPTION "An event to report the success of a Software Download."
::= 2
an50PswdChangeFailTrap TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50SysLastTrapTime }
DESCRIPTION "An event to report the failure of a password change."
::= 3
an50FirmwareConfigFailTrap TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50SysLastTrapTime }
DESCRIPTION "An event to report the failure of a firmware config."
::= 4
an50EepromCorruptedTrap TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50SysLastTrapTime }
DESCRIPTION "An event to report the corruption of the EEPROM."
::= 5
an50PowerSupplyFailureTrap TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50SysLastTrapTime }
DESCRIPTION "An event to report the power supply failure."
::= 6
an50SaveConfigTrap TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50SysLastTrapTime }
DESCRIPTION "An event to report the saving of configuration"
::= 7
an50ModifiedIDTrap TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50pmpLastModifiedCID,
an50SysLastTrapTime }
DESCRIPTION "An event to report the modification in the configuration of a CID"
::= 8
an50pmpRegistrationMissed TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50pmpLastMissedSsMacAddress,
an50SysLastTrapTime }
DESCRIPTION "An event to report the missing of the registration by a AN50 Subscriber to one BS.This trap is sent by the BS and contains the MAC address of the SS missing the registration"
::= 9
an50pmpRegistrationSuccessful TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50pmpLastRegisteredSsMacAddress,
an50SysLastTrapTime }
DESCRIPTION "An event to report the successful registration of an AN50 Subscriber to BS.This trap is sent by the BS and contains the MAC address of the newly registered SS"
::= 10
an50DFSEvent TRAP-TYPE
ENTERPRISE redline
VARIABLES { an50SysLastTrapTime }
DESCRIPTION "An event to report a DFS event in AN50"
::= 11
an50MaxCid OBJECT-TYPE
SYNTAX INTEGER (1 .. 1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The maximum number of CID for this equipment"
::= { an50LinkPmp 1 }
an50LinkCurrentAvailId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The maximum number of CID for this equipment"
::= { an50LinkPmp 2 }
END