-- SECTION 1: Top Level Definitions
|
|
|
|
S5-AGENT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
-- 5000 Agent MIB Release 1.3.9
|
|
-- Revision 10/14/98
|
|
|
|
-- Copyright 1995-98 Bay Networks, Inc.
|
|
-- All rights reserved.
|
|
-- This Bay Networks SNMP Management Information Base Specification
|
|
-- (Specification) embodies Bay Networks' confidential and
|
|
-- proprietary intellectual property. Bay Networks retains all
|
|
-- title and ownership in the Specification, including any
|
|
-- revisions.
|
|
|
|
-- This Specification is supplied "AS IS," and Bay Networks makes
|
|
-- no warranty, either express or implied, as to the use,
|
|
-- operation, condition, or performance of the Specification.
|
|
|
|
|
|
-- Imports
|
|
|
|
IMPORTS
|
|
IpAddress, TimeTicks
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
s5Agent
|
|
FROM S5-ROOT-MIB
|
|
TimeIntervalSec, IpxAddress, MacAddress
|
|
FROM S5-TCS-MIB;
|
|
|
|
|
|
-- Agent Groups
|
|
|
|
s5AgentHw OBJECT IDENTIFIER ::= { s5Agent 1 }
|
|
s5AgentInfo OBJECT IDENTIFIER ::= { s5Agent 2 }
|
|
s5AgentMgmt OBJECT IDENTIFIER ::= { s5Agent 3 }
|
|
|
|
|
|
|
|
-- SECTION 2: MIB Objects
|
|
|
|
-- Hardware Information
|
|
|
|
s5AgMyGrpIndx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the group containing
|
|
the agent."
|
|
::= { s5AgentHw 1 }
|
|
|
|
s5AgMyComIndx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the component containing
|
|
the agent."
|
|
::= { s5AgentHw 2 }
|
|
|
|
|
|
-- Global Information
|
|
|
|
s5AgentGbl OBJECT IDENTIFIER ::= { s5AgentInfo 1 }
|
|
|
|
s5AgInfoReBoot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
running(2),
|
|
restart(3),
|
|
reboot(4),
|
|
reset(5),
|
|
download(6),
|
|
downloadAndRestart(7),
|
|
downloadAndReboot(8),
|
|
downloadAndReset(9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Action object to reboot the agent.
|
|
The following values can only be read:
|
|
other(1).....agent in unknown or other state
|
|
running(2)...agent running
|
|
|
|
The following values can be written:
|
|
restart(3)...restart agent (i.e., jump to
|
|
beginning of agent code)
|
|
reboot(4)....start boot sequence for agent
|
|
(i.e., jump to beginning of
|
|
boot firmware)
|
|
reset(5).....do a hardware reset
|
|
download(6)..............activate download of
|
|
a new agent
|
|
downloadAndRestart(7)....activate download of
|
|
a new agent and restart
|
|
downloadAndReboot(8).....activate download of
|
|
a new agent and reboot
|
|
downloadAndReset(9)......activate download of
|
|
a new agent and reset
|
|
|
|
If s5AgInfoScheduleBootTime is set in the same PDU as
|
|
s5AgInfoReBoot, the action specified occurs when the
|
|
scheduled time reaches zero; otherwise, the action
|
|
occurs immediately. The agent does best efforts to
|
|
return a response before the action occurs.
|
|
|
|
If any of the combined download actions are
|
|
requested, neither action occurs until the
|
|
expiry of s5AgInfoScheduleBootTime, if set."
|
|
::= { s5AgentGbl 1 }
|
|
|
|
s5AgInfoWriteCfg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
valid(2),
|
|
write(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Action object to cause current configuration
|
|
settings to be written to local nonvolatile
|
|
storage. The following values can only be read:
|
|
other(1)...some unknown or other state
|
|
valid(2)...contents valid
|
|
|
|
The following value can be written:
|
|
write(3)...write configuration settings to
|
|
local storage (such as nonvol)
|
|
|
|
If the write operation write fails, then the
|
|
agent will return error 'genErr' on the SET."
|
|
::= { s5AgentGbl 2 }
|
|
|
|
s5AgInfoMgmtProtocolNxtBoot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ipOnly(2),
|
|
ipxOnly(3),
|
|
ipAndIpx(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The transport protocol(s) to use after
|
|
the next boot of the agent. The following
|
|
value is read-only:
|
|
other(1)....unknown or some other protocol
|
|
|
|
The following value is read-write:
|
|
ipOnly(2).....only IP
|
|
ipxOnly(3)....only IPX
|
|
ipAndIpx(4)...IP and IPX."
|
|
::= { s5AgentGbl 3 }
|
|
|
|
s5AgInfoMgmtProtocolCur OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ipOnly(2) ,
|
|
ipxOnly(3),
|
|
ipAndIpx(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current transport protocol(s) that are
|
|
being supported by the agent. The following
|
|
value is read-only:
|
|
other(1)....unknown or some other protocol
|
|
|
|
The following value is read-write:
|
|
ipOnly(2).....only IP
|
|
ipxOnly(3)....only IPX
|
|
ipAndIpx(4)...IP and IPX.
|
|
|
|
When the IP protocol stack is not enabled,
|
|
the agent will not respond to PING or SNMP
|
|
requests over IP.
|
|
|
|
When the IPX protocol stack is not enabled,
|
|
the agent will not respond to diagnostic SAP or
|
|
SNMP requests over IPX.
|
|
|
|
It is suggested that NMS not disable the transport
|
|
they are using."
|
|
::= { s5AgentGbl 4 }
|
|
|
|
s5AgInfoBootMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
local(2),
|
|
net(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source for initial protocol configuration
|
|
information at next boot. For IP, a setting of
|
|
net(3) means that BOOTP will be used to get the
|
|
agent's IP address(es), load server address, and
|
|
configuration file name. For IPX, a setting of net(3)
|
|
means SAP will be used to get the agent's Novell
|
|
network number(s), and the configuation filename
|
|
will be loaded from local storage (note - the load
|
|
server address is not needed in a Novell network).
|
|
|
|
The following value is read-only:
|
|
other(1).....not applicable or some other case
|
|
|
|
The following values are read-write:
|
|
local(2).....don't use the network
|
|
net(3).......try using the network and if that
|
|
fails then use protocol configuration
|
|
information from local storage.
|
|
|
|
Note: The load server address is not configurable
|
|
and is not available in this MIB object on a
|
|
Novell network."
|
|
::= { s5AgentGbl 5 }
|
|
|
|
s5AgInfoCfgLoadMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
local(2),
|
|
net(3),
|
|
locAsBk(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source from which to load configuration
|
|
information at next boot. The following value
|
|
is read-only:
|
|
other(1)...not applicable or some other case
|
|
|
|
The following values are read-write:
|
|
local(2).....get from local storage
|
|
net(3).......load from the network
|
|
locAsBk(4)...try using network and if it fails
|
|
then use local information.
|
|
|
|
When local(2) is specified, the configuration
|
|
information is loaded from local storage.
|
|
If the local configuration is not valid
|
|
(checks for ip = 0.0.0.0), then BOOTP is used
|
|
for the IP stack. (In IPX only mode, the IP
|
|
address could be 0.0.0.0 and IPX does not rely
|
|
on the IP address. The agent checks the IPX
|
|
address, and if the network number of the IPX
|
|
address is equal to 0 the agent uses SAP).
|
|
|
|
When net(3) is specified, the configuration
|
|
information will be downloaded from the network
|
|
only. The configuration information will never
|
|
be loaded from local storage, even if downloading
|
|
fails and the local configuration information exists.
|
|
|
|
When locAsBk(4) is specified, a download of the
|
|
configuration information will be tried over the
|
|
network. If the network download fails then the
|
|
configuration information will be loaded from
|
|
local storage."
|
|
::= { s5AgentGbl 6 }
|
|
|
|
s5AgInfoImgLoadMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
local(2),
|
|
net(3),
|
|
locAsBk(4),
|
|
netIfNewer(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source from which to load the agent image
|
|
at next boot. The following value is read-only:
|
|
other(1)...not applicable or some other case
|
|
|
|
The following values are read-write:
|
|
local(2)........get from local storage
|
|
net(3)..........load from the network
|
|
locAsBk(4)......try using network and if it fails
|
|
then use local information.
|
|
netIfNewer(5)...try loading image over the net.
|
|
If can load image, and it is newer
|
|
than the local image, then use it.
|
|
Otherwise, use local image.
|
|
|
|
If the local image is not valid, the setting will
|
|
be net(3) and cannot be changed to local(2),
|
|
or locAsBk(4) until a valid image file is loaded
|
|
(i.e., error 'badValue' will be returned on SETS with
|
|
value other than net(3)). When the local image is
|
|
not valid and the network download of the image fails,
|
|
the entire boot process will be repeated.
|
|
|
|
When local(2) is specified, the image will be loaded
|
|
from local storage.
|
|
|
|
When net(3) is specified, the image will be downloaded
|
|
from the network only. The image file will never be
|
|
loaded from local storage, even if downloading fails
|
|
and the local image exists.
|
|
|
|
When locAsBk(4) is specified, a download of the image
|
|
will be tried over the network. If the network
|
|
download fails then the image is loaded from local
|
|
storage.
|
|
|
|
When netIfNewer(5) is specified, a download of the
|
|
image will be tried over the network. If successful,
|
|
it will then be compared to the image stored in local
|
|
storage. The most recent version of the two will be
|
|
used. If the local image is not valid, the network
|
|
will always be used. If the network download fails
|
|
then the image is loaded from the local storage."
|
|
::= { s5AgentGbl 7 }
|
|
|
|
s5AgInfoImgSaveMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
writeIfDiff(2),
|
|
writeIfNewer(3),
|
|
noWrite(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates what to do with the image (when
|
|
loaded from the network) on the next boot.
|
|
The following value can only be read:
|
|
notAvail(1)...the save operation is not
|
|
available
|
|
|
|
The following values can be written (and
|
|
read) if the device supports this capability:
|
|
writeIfDiff(2)....save image to local storage
|
|
at next boot if image is
|
|
different from saved contents
|
|
writeIfNewer(3)...save image to local storage
|
|
at next boot if image is
|
|
newer than saved contents.
|
|
noWrite(4)........do not save image to local
|
|
storage at next boot, even if
|
|
image is newer or different."
|
|
::= { s5AgentGbl 8 }
|
|
|
|
s5AgInfoImgSaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
noSave(2),
|
|
saved(3),
|
|
saveFailed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates what happened to the image file
|
|
on the last boot. The following values
|
|
are returned:
|
|
notAvail(1).....the save operation is not
|
|
available
|
|
noSave(2).......image not saved since image was
|
|
not asked to be saved, or image
|
|
was not loaded from the network
|
|
saved(3)........image saved
|
|
saveFailed(4)...tried to save image, but failed"
|
|
::= { s5AgentGbl 9 }
|
|
|
|
s5AgInfoVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The version of the agent in the form
|
|
'major.minor.maintenance[letters]'. This
|
|
is an alias for the value of the object
|
|
s5ChasStoreCntntVer for the RAM of the
|
|
module containing the agent."
|
|
::= { s5AgentGbl 10 }
|
|
|
|
s5AgInfoLocStorVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The version of the agent image saved in local
|
|
storage such as flash memory in the form
|
|
'major.minor.maintenance[letters]'. If not
|
|
known or not available, then the value is
|
|
a zero length string. This is an alias for
|
|
the value of the object s5ChasStoreCntntVer
|
|
for the local storage of the module containing
|
|
the agent."
|
|
::= { s5AgentGbl 11 }
|
|
|
|
s5AgInfoNxtBootDfltGwAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the default gateway (router)
|
|
for the agent to use after the next boot. (NOTE:
|
|
the current default router is the value of object
|
|
s5AgInfoCurDfltGwAddr (or ipRouteNextHop.0.0.0.0).)
|
|
|
|
If not used, then this object has the value
|
|
of 0.0.0.0."
|
|
::= { s5AgentGbl 12 }
|
|
|
|
s5AgInfoCurDfltGwAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the current default gateway
|
|
(router). (NOTE: this is an alias for the object
|
|
ipRouteNextHop in the row of the table
|
|
ipRouteTable which has object ipRouteDest with
|
|
a value of 0.0.0.0.)
|
|
|
|
If not used, then this object has the value
|
|
of 0.0.0.0."
|
|
::= { s5AgentGbl 13 }
|
|
|
|
s5AgInfoDramUsage OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An indication of the percentage of DRAM currently
|
|
in use by this agent. If this information is not
|
|
available the agent shall return -1, otherwise the
|
|
percentage of DRAM in use is returned as an integer
|
|
between 0 and 100. The percentage is defined as the
|
|
DRAM currently used by this agent divided by the
|
|
total DRAM available to this agent."
|
|
::= { s5AgentGbl 14 }
|
|
|
|
s5AgInfoLoadProtocolNxtBoot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ipOnly(2),
|
|
ipxOnly(3),
|
|
auto(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The transport protocol(s) over which the
|
|
agent is to use to load the configuration
|
|
information and the agent image at the
|
|
next boot of the agent. The following
|
|
value is read-only:
|
|
other(1)....unknown or some other protocol
|
|
|
|
The following values are read-write:
|
|
ipOnly(2)....use load protocol over IP
|
|
ipxOnly(3)...use load protocol over IPX
|
|
auto(4)......try using the IP load function
|
|
and if that fails then use IPX
|
|
load function. If the IPX
|
|
load function also fails, repeat
|
|
the same process until one or
|
|
the other protocol succeeds."
|
|
::= { s5AgentGbl 15 }
|
|
|
|
s5AgInfoLoadProtocolLast OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reserved(1),
|
|
ip(2),
|
|
ipx(3),
|
|
local(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The transport protocol over which the agent image
|
|
and configuration information were last loaded. The
|
|
following values are read-only:
|
|
reserved(1)...reserved
|
|
ip(2).........gotten from the network using
|
|
a load protocol over IP
|
|
ipx(3)........gotten from the network using
|
|
a load protocol over IPX
|
|
local(4)......loaded from local storage."
|
|
::= { s5AgentGbl 16 }
|
|
|
|
|
|
s5AgInfoSlotScope OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains information about all
|
|
the slots an agent can manage. The value is encoded
|
|
in an octet string. One byte has information about 8
|
|
slots. If a bit is set then agent can manage the
|
|
corresponding slot. Byte 1 will have information about
|
|
slots 1-8, byte 2 will have information about
|
|
slots 9-16, and so on. For example an agent that
|
|
can manage slots 2-7 in a 14 slot chassis should have
|
|
the value :
|
|
8d:00 (0111 1110 0000 0000)
|
|
If an agent returns a string of size 0, then it can
|
|
manage all slots in chassis."
|
|
::= { s5AgentGbl 17 }
|
|
|
|
s5AgInfoImgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
typeA(2),
|
|
typeB(3),
|
|
typeC(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of agent image. This object is meant
|
|
to distinguish between agents having the same version
|
|
number running on the same hardware, but with dissimilar
|
|
functionality. Following are examples of possible values
|
|
for various enumerations.
|
|
other(1) ....... A unique agent eg., 5310A, 5dn310 etc
|
|
typeA(2) ....... fusion basic agent.
|
|
typeB(2) ....... fusion advanced agent."
|
|
::= { s5AgentGbl 18 }
|
|
|
|
s5AgInfoScheduleBootTime OBJECT-TYPE
|
|
SYNTAX INTEGER (0..10080)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time, measured in minutes, remaining until the
|
|
action(s) set by s5AgInfoReBoot will be performed.
|
|
This value must be set in the same set request as
|
|
the value of s5AgInfoReBoot; otherwise, a badValue
|
|
error is returned.
|
|
|
|
If this value has been set, the number returned will
|
|
count down to zero, and the time remaining in minutes
|
|
will be rounded up to the next whole minute.
|
|
|
|
Actions set via s5AgInfoReBoot can be scheduled for
|
|
up to seven days in advance.
|
|
7 * 24 * 60 equals the maximum settable value of
|
|
10080. If this attribute has not been set, a value of
|
|
zero should be returned."
|
|
::= { s5AgentGbl 19 }
|
|
|
|
s5AgInfoScheduleBootCancel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
cancel(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Cancel a scheduled s5AgInfoReboot action.
|
|
The following value is read-only:
|
|
other(1)...not applicable or some other case
|
|
This is always the value that return when
|
|
read.
|
|
|
|
The following values are read-write:
|
|
cancel(2)...cancel a scheduled boot.
|
|
|
|
Setting this attribute to cancel(2) sets s5AgInfoReBoot
|
|
to running(2) and s5AgInfoScheduleBootTime to zero."
|
|
::= { s5AgentGbl 20 }
|
|
|
|
s5AgInfoNumBootBanks OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of local storage locations (or flash
|
|
memory banks) available on this device for
|
|
operational code images.
|
|
|
|
Devices without local image capability or not
|
|
supporting this attribute shall return a value of 0."
|
|
::= { s5AgentGbl 21 }
|
|
|
|
|
|
s5AgInfoNextBootBank OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source of the image to be loaded upon the
|
|
next boot of the device.
|
|
|
|
If a value is set larger than s5AgInfoNumBootBanks,
|
|
a badValue error should be returned.
|
|
|
|
Devices without local image capability or not
|
|
supporting this attribute shall return a value of 0."
|
|
::= { s5AgentGbl 22 }
|
|
|
|
|
|
|
|
s5AgInfoDstLoadBank OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The local storage bank where the next system image
|
|
image is downloaded to.
|
|
|
|
Devices without local image capability or not
|
|
supporting this attribute shall return a value of 0."
|
|
::= { s5AgentGbl 23 }
|
|
|
|
s5AgInfoFileAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
dnldConfig(2),
|
|
dnldImg(3),
|
|
upldConfig(4),
|
|
upldImg(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to download or upload a config file or
|
|
an image file.
|
|
|
|
In read operation, if no action taken since the boot up, it will
|
|
return other(1). Otherwise it will return the latest action such
|
|
as dnldConfig(2), dnldImg(3), upldConfig(4) and upldImg(5).
|
|
|
|
In write operation, the values that can be written are:
|
|
|
|
dnldConfig(2) ... download a config file to a device. The new
|
|
config file will not take effect until the
|
|
next boot cycle of the device.
|
|
dnldImg(3) ...... download an image to a device.
|
|
upldConfig(4) ... upload a config file to a server from
|
|
a device. The config file contains the current MIB object values of the device.
|
|
upldImg(5) ...... upload a image from a device to a server"
|
|
|
|
::= {s5AgentGbl 24}
|
|
|
|
|
|
s5AgInfoFileStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
inProgress (2),
|
|
success (3),
|
|
fail (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to get the status of the latest action as
|
|
shown by s5AgInfoFileAction. The values that can be read are:
|
|
|
|
other(1) ......... if no action taken since the boot up
|
|
inProgress (2) ... the operation is in progress
|
|
success (3) ...... the operation succeeds.
|
|
fail (4) ......... the operation is failed."
|
|
|
|
::= {s5AgentGbl 25}
|
|
|
|
|
|
-- Agent's Interface Information Table
|
|
|
|
|
|
s5AgMyIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5AgMyIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that provides additional information
|
|
about the agent's interfaces. The number of
|
|
entries in the table is determined by the
|
|
number of interfaces on the agent."
|
|
::= { s5AgentInfo 2 }
|
|
|
|
|
|
s5AgMyIfEntry OBJECT-TYPE
|
|
SYNTAX S5AgMyIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A row in the table of additional information
|
|
about the agent's interfaces. Entries can not
|
|
be created or deleted via SNMP requests."
|
|
INDEX { s5AgMyIfIndx }
|
|
::= { s5AgMyIfTable 1 }
|
|
|
|
|
|
S5AgMyIfEntry ::= SEQUENCE {
|
|
s5AgMyIfIndx INTEGER,
|
|
s5AgMyIfNxtBootIpAddr IpAddress,
|
|
s5AgMyIfNxtBootNetMask IpAddress,
|
|
s5AgMyIfCfgFname DisplayString,
|
|
s5AgMyIfLdSvrAddr IpAddress,
|
|
s5AgMyIfImgFname DisplayString,
|
|
s5AgMyIfValidFlag INTEGER,
|
|
s5AgMyIfNxtBootIpxAddr IpxAddress,
|
|
s5AgMyIfBootRouterAddr IpAddress,
|
|
s5AgMyIfMacAddr MacAddress
|
|
}
|
|
|
|
|
|
|
|
s5AgMyIfIndx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the interface. This has the same
|
|
value as ifIndex for the interface."
|
|
::= { s5AgMyIfEntry 1 }
|
|
|
|
s5AgMyIfNxtBootIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the next boot, the IP address of the
|
|
the interface. If not used, then the
|
|
value is 0.0.0.0. (NOTE: the current IP
|
|
address for the interface is found in table
|
|
ipAddrTable and in table s5AgOthIfTable.)"
|
|
::= { s5AgMyIfEntry 2 }
|
|
|
|
s5AgMyIfNxtBootNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the next boot, the subnet mask for
|
|
the interface. If not used, then the
|
|
value is 0.0.0.0. (NOTE: the current subnet
|
|
mask for the interface is found in table
|
|
ipAddrTable.)"
|
|
::= { s5AgMyIfEntry 3 }
|
|
|
|
s5AgMyIfCfgFname OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the configuration file currently
|
|
associated with the interface. When not
|
|
used, the value is a zero length string."
|
|
::= { s5AgMyIfEntry 4 }
|
|
|
|
s5AgMyIfLdSvrAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the load server for the
|
|
configuration file and/or the image file.
|
|
If not used, then the value is 0.0.0.0"
|
|
::= { s5AgMyIfEntry 5 }
|
|
|
|
s5AgMyIfImgFname OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the image file(s) currently associated
|
|
with the interface. Some agents in special
|
|
situations may support a value which contains
|
|
multiple file names instead of a single file
|
|
name. Multiple names are specified as a list
|
|
of file names separated by semicolons (;).
|
|
When the object is not used, the value is a
|
|
zero length string."
|
|
::= { s5AgMyIfEntry 6 }
|
|
|
|
s5AgMyIfValidFlag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
invalid(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the configuration and/or image
|
|
file(s) were downloaded from this interface and
|
|
if the file names have not been changed. The
|
|
following values can be read:
|
|
valid(1).....configuration and/or image file(s)
|
|
downloaded from this interface
|
|
are currently in use
|
|
invalid(2)...cfg and/or image files downloaded
|
|
from this interface are not
|
|
in use (this may also mean that
|
|
there are no files downloaded from
|
|
this interface)."
|
|
::= { s5AgMyIfEntry 7 }
|
|
|
|
s5AgMyIfNxtBootIpxAddr OBJECT-TYPE
|
|
SYNTAX IpxAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the next boot, the IPX address of the
|
|
the interface. If the IPX protocol is not used,
|
|
then the value is 00000000:000000000000.
|
|
|
|
NOTE: The current IPX address for the
|
|
interface is found in table s5AgOthIfTable."
|
|
::= { s5AgMyIfEntry 8 }
|
|
|
|
|
|
s5AgMyIfBootRouterAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the boot router for the
|
|
configuration file and/or the image file.
|
|
If not used, then the value is 0.0.0.0"
|
|
::= { s5AgMyIfEntry 9 }
|
|
|
|
s5AgMyIfMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MAC address of the interface. The value
|
|
is 00:00:00:00:00:00 if there is no interface."
|
|
::= { s5AgMyIfEntry 10}
|
|
|
|
|
|
|
|
-- Other Agents' Interface Information Table
|
|
|
|
s5AgOthIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5AgOthIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that provides information about
|
|
each interface for each agent in the chassis.
|
|
The number of entries in the table is determined
|
|
by the number of agents in the chassis and their
|
|
configuration."
|
|
::= { s5AgentInfo 3 }
|
|
|
|
s5AgOthIfEntry OBJECT-TYPE
|
|
SYNTAX S5AgOthIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A row in the table of information about interface
|
|
information for all agents in the chassis. Entries
|
|
can not be created or deleted via SNMP requests."
|
|
INDEX { s5AgOthIfGrpIndx,
|
|
s5AgOthIfComIndx,
|
|
s5AgOthIfIndx }
|
|
::= { s5AgOthIfTable 1 }
|
|
|
|
S5AgOthIfEntry ::= SEQUENCE {
|
|
s5AgOthIfGrpIndx INTEGER,
|
|
s5AgOthIfComIndx INTEGER,
|
|
s5AgOthIfIndx INTEGER,
|
|
s5AgOthIfIpAddr IpAddress,
|
|
s5AgOthIfIpxAddr IpxAddress
|
|
}
|
|
|
|
s5AgOthIfGrpIndx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the group containing the component
|
|
containing the agent."
|
|
::= { s5AgOthIfEntry 1 }
|
|
|
|
s5AgOthIfComIndx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the component in the group
|
|
containing the agent."
|
|
::= { s5AgOthIfEntry 2 }
|
|
|
|
s5AgOthIfIndx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the interface. This is the same
|
|
value as ifIndex."
|
|
::= { s5AgOthIfEntry 3 }
|
|
|
|
s5AgOthIfIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the interface. If not used,
|
|
then the value is 0.0.0.0."
|
|
::= { s5AgOthIfEntry 4 }
|
|
|
|
s5AgOthIfIpxAddr OBJECT-TYPE
|
|
SYNTAX IpxAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX address of the interface. If the IPX
|
|
protocol is not used, then the value is
|
|
00000000:000000000000."
|
|
::= { s5AgOthIfEntry 5 }
|
|
|
|
|
|
|
|
-- IP Router Aging And Default Router Selection Information
|
|
|
|
s5AgIpRtrDefaultTimeToLive OBJECT-TYPE
|
|
SYNTAX TimeIntervalSec (60..3600)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The lifetime of IP router entries in seconds.
|
|
The maximum length of time that a IP router
|
|
is to be considered alive in the absence of
|
|
further positive advice. The default lifetime
|
|
is used for routers learned through IP router
|
|
protocols that do not specify a lifetime (e.g.
|
|
statically configured, ICMP redirects)."
|
|
DEFVAL { 540 } -- 9 minutes
|
|
::= { s5AgentInfo 4 }
|
|
|
|
s5AgIpDefaultRtrSelectionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
config(2),
|
|
static(3),
|
|
dynamic(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The method used to select a default IP router.
|
|
The following value is read-only:
|
|
other(1).......not applicable or other case
|
|
The following values are read-write:
|
|
config(2).....use configured primary default
|
|
router. If no primary default router
|
|
is specified, there will be no
|
|
default IP route.
|
|
static(3).....A default router will be chose from
|
|
the routers known to be up and that
|
|
have been configured.
|
|
dynamic(4)....ICMP router discovery as per RFC
|
|
1256 is performed and the router
|
|
with the highest preference level is
|
|
chosen as default router."
|
|
DEFVAL { dynamic }
|
|
::= { s5AgentInfo 5 }
|
|
|
|
s5AgIpRtrDiscoverySolicitMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
multicast(1),
|
|
broadcast(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The router discovery solicitation mode to use
|
|
when the default router selection mode is
|
|
dynamic. This solicitation mode determines
|
|
the IP address for ICMP router solicitations
|
|
(see RFC 1256):
|
|
multicast(1)..router solicitations are sent to
|
|
the all-routers multicast address
|
|
(224.0.0.2)
|
|
broadcast(2)..router solicitations are sent to
|
|
the limited broadcast address
|
|
(255.255.255.255)."
|
|
DEFVAL { broadcast}
|
|
::= { s5AgentInfo 6 }
|
|
|
|
|
|
|
|
-- Agent's Data Collection Table
|
|
|
|
s5AgDataCollectTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5AgDataCollectEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of control information and statistics
|
|
for the data collection (promiscuous data
|
|
capturing) per source of detection."
|
|
::= { s5AgentInfo 7 }
|
|
|
|
s5AgDataCollectEntry OBJECT-TYPE
|
|
SYNTAX S5AgDataCollectEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A row in the data collection table.
|
|
Entries can not be created or deleted
|
|
via SNMP."
|
|
INDEX { s5AgDataCollectIfIndex }
|
|
::= { s5AgDataCollectTable 1 }
|
|
|
|
S5AgDataCollectEntry ::= SEQUENCE {
|
|
s5AgDataCollectIfIndex INTEGER,
|
|
s5AgDataCollectSnTimeStamp TimeTicks,
|
|
s5AgDataCollectNetworkAddrStatus INTEGER
|
|
}
|
|
|
|
s5AgDataCollectIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An integer value representing the source
|
|
that collects data from the network. A value
|
|
greater than zero is the index of the agent's
|
|
interface on the NMM. This is the same value
|
|
as ifIndex for the interface. A value of zero
|
|
indicates data collection via best available
|
|
efforts (other than NMM's interfaces)."
|
|
::= { s5AgDataCollectEntry 1 }
|
|
|
|
s5AgDataCollectSnTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the last time
|
|
a node was added or deleted from the
|
|
Show Node table."
|
|
::= { s5AgDataCollectEntry 2 }
|
|
|
|
|
|
s5AgDataCollectNetworkAddrStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysOff(1),
|
|
on(2),
|
|
off(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A switch to enable or disable the collecting of
|
|
network layer addresses for the network address
|
|
mapping table (s5CmNetAddrTable ).
|
|
The following value is read-only:
|
|
alwaysOff(1)..data source is not capable of
|
|
collecting or decoding network
|
|
addresses
|
|
|
|
The following values are read-write if the data
|
|
source is capable of collecting network addresses:
|
|
on(2).........packet decoding is enabled
|
|
off(3)........packet decoding is disabled
|
|
or not supported."
|
|
DEFVAL { on } -- if packet collection is possible
|
|
::= { s5AgDataCollectEntry 3 }
|
|
|
|
|
|
|
|
-- Authentication Trap VarBinds
|
|
|
|
|
|
s5AgUnAuthIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the IP address of the last
|
|
station that tried to access this agent with an
|
|
invalid community string. This object is used as
|
|
a VarBind in an Authentication Trap PDU. A get
|
|
request will return the last value used, and will
|
|
return the null address 0.0.0.0 if no IP
|
|
authentication traps have been sent."
|
|
::= { s5AgentInfo 8 }
|
|
|
|
s5AgUnAuthIpxAddr OBJECT-TYPE
|
|
SYNTAX IpxAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the IPX address of the last
|
|
station that tried to access this agent with an
|
|
invalid community string. This object is used as
|
|
a VarBind in an Authentication Trap PDU. A get
|
|
request will return the last value used, and will
|
|
return the null address of all zeros if no IPX
|
|
authentication traps have been sent."
|
|
::= { s5AgentInfo 9 }
|
|
|
|
s5AgUnAuthComm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..20))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the community string of the
|
|
last unauthenticated attempt to access this agent.
|
|
This object is used as a VarBind in an Authentication
|
|
Trap PDU. A get request will return the last value used,
|
|
and will return the null string if no authentication
|
|
traps have been sent."
|
|
::= { s5AgentInfo 10 }
|
|
|
|
s5AgTrapFilterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5AgTrapFilterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Agent Trap filter configuration table."
|
|
::= { s5AgentInfo 11 }
|
|
|
|
s5AgTrapFilterEntry OBJECT-TYPE
|
|
SYNTAX S5AgTrapFilterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of trap filter entries that determine the
|
|
filtering of traps. For example, an instance of the
|
|
s5AgtTrapFilterStatus will be named s5AgTrapFilterStatus.8"
|
|
INDEX { s5AgTrapFilterIndex }
|
|
::= { s5AgTrapFilterTable 1 }
|
|
|
|
S5AgTrapFilterEntry ::= SEQUENCE {
|
|
s5AgTrapFilterIndex INTEGER,
|
|
s5AgTrapFilterTrapOID OBJECT IDENTIFIER,
|
|
s5AgTrapFilterTrapInitiator1 INTEGER,
|
|
s5AgTrapFilterTrapInitiator2 INTEGER,
|
|
s5AgTrapFilterTrapInitiator3 INTEGER,
|
|
s5AgTrapFilterStatus INTEGER,
|
|
s5AgTrapFilterDelayTime INTEGER,
|
|
s5AgTrapEntryStatus INTEGER
|
|
}
|
|
|
|
s5AgTrapFilterIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An index that uniquely identifies an entry in the
|
|
s5AgTrapFilterTable."
|
|
::= { s5AgTrapFilterEntry 1 }
|
|
|
|
s5AgTrapFilterTrapOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The OID of the trap.
|
|
|
|
This variable is requried for row creation."
|
|
::= { s5AgTrapFilterEntry 2 }
|
|
|
|
s5AgTrapFilterTrapInitiator1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value that determines the first condition for
|
|
filtering a trap.This entry is the value of the
|
|
first varbind for a particular trap in most cases.
|
|
|
|
We need to specify every initiator that represents
|
|
the corresponding trap variable for each trap.
|
|
If the value of this initiator is 0 (wildcard or
|
|
don't care), it means that it can represent all
|
|
possible values for this initiator. The trap-filter
|
|
design and functional spec. provides a more detailed
|
|
explanation on this subject."
|
|
::= { s5AgTrapFilterEntry 3 }
|
|
|
|
s5AgTrapFilterTrapInitiator2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value that determines the second condition for
|
|
filtering a trap. This entry is the value of the
|
|
second varbind for most traps. If the value of
|
|
this initiator is 0 (wildcard or don't care),
|
|
it means that it can represent all possible values
|
|
for this initiator. If a trap has only one varbind,
|
|
this entry should be set to 0."
|
|
::= { s5AgTrapFilterEntry 4 }
|
|
|
|
s5AgTrapFilterTrapInitiator3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value that determines the third condition for
|
|
filtering a trap. This entry is the value of the
|
|
third varbind for most traps. If the value of this
|
|
initiator is 0(wildcard or don't care), it means
|
|
that it can represent all possible values for this
|
|
initiator. If a trap has only one or two varbinds,
|
|
this entry should be set to 0."
|
|
::= { s5AgTrapFilterEntry 5 }
|
|
|
|
s5AgTrapFilterStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether this trap is enabled or not.
|
|
enabled(1) indicates that if this type of event
|
|
occurs, a trap that is generated will be queued
|
|
for transmit. disabled(2) indicates that if this
|
|
trap if generated, it will not be queued for
|
|
transmit and s5AgTrapFilterDelayTime is not valid."
|
|
::= { s5AgTrapFilterEntry 6 }
|
|
|
|
|
|
s5AgTrapFilterDelayTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time delay period required to be met, between
|
|
each consecutive occurences of this event. Traps
|
|
recieved within this period will be dropped."
|
|
::= { s5AgTrapFilterEntry 7 }
|
|
|
|
s5AgTrapEntryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
createRequest(2),
|
|
underCreation(3),
|
|
invalid(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A manager is restricted to change the state of an
|
|
entry base on the following table:
|
|
|
|
create under
|
|
To: valid Request Creation invalid
|
|
From:
|
|
valid OK NO OK OK
|
|
createRequest N/A N/A N/A N/A
|
|
underCreation OK NO OK OK
|
|
invalid NO NO NO OK
|
|
nonExistent NO OK NO OK
|
|
|
|
In the table above, it is not applicable to change
|
|
the state from createRequest to any other states.
|
|
|
|
When the status of a table entry is set to the value
|
|
of invalid(4), the entry will be removed from the table.
|
|
If an entry has been in the underCreation(3) state for
|
|
more than 10 minutes, it will be set to invalid(4) and
|
|
subsequently removed from the table.
|
|
|
|
This variable is requried for row creation."
|
|
::= { s5AgTrapFilterEntry 8 }
|
|
|
|
|
|
-- change '_' to '-' for enum named label
|
|
-- yyang 11/30/98
|
|
s5AgTrapFilterGlobalStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
enable-all(1),
|
|
disable-all(2),
|
|
enable-all-and-use-table(3),
|
|
disable-all-and-use-table(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value is the status of all the traps that
|
|
supported by this trap-filter system.
|
|
|
|
If the value is 1 (enable all) , all traps in the
|
|
system are enabled. If the value is 2 (disable all),
|
|
all traps in the system are disabled. If the value
|
|
is 3 (enable-all-and-use-table) all traps are enabled
|
|
except for traps that are disabled in the
|
|
s5AgTrapFilterTable are disabled. If the value is 4
|
|
(disable-all-and-use-table) all traps are disabled
|
|
except for traps that are enabled in the
|
|
s5AgTrapFilterTable are enabled."
|
|
::= { s5AgentInfo 12 }
|
|
|
|
|
|
|
|
|
|
-- Trap Receiver Table
|
|
|
|
s5AgTrpRcvrMaxEnt OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of rows in the trap
|
|
receiver table."
|
|
::= { s5AgentMgmt 1 }
|
|
|
|
s5AgTrpRcvrCurEnt OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current number of rows in the trap
|
|
receiver table."
|
|
::= { s5AgentMgmt 2 }
|
|
|
|
s5AgTrpRcvrNext OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the next available row to be
|
|
created in the trap receiver table. A value
|
|
of zero means that the table is full and no
|
|
more rows can be added."
|
|
::= { s5AgentMgmt 3 }
|
|
|
|
s5AgTrpRcvrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5AgTrpRcvrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managers which to send traps."
|
|
::= { s5AgentMgmt 4 }
|
|
|
|
s5AgTrpRcvrEntry OBJECT-TYPE
|
|
SYNTAX S5AgTrpRcvrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A row in the trap receiver table.
|
|
The column s5AgTrpRcvrStatus is used to create
|
|
and delete rows in the table. Creation requires
|
|
a SET PDU with objects s5AgTrpRcvrStatus,
|
|
s5AgTrpRcvrAddrType, s5AgTrpRcvrNetAddr,
|
|
and s5AgTrpRcvrComm for the new row."
|
|
INDEX { s5AgTrpRcvrIndx }
|
|
::= { s5AgTrpRcvrTable 1 }
|
|
|
|
S5AgTrpRcvrEntry ::= SEQUENCE {
|
|
s5AgTrpRcvrIndx INTEGER,
|
|
s5AgTrpRcvrStatus INTEGER,
|
|
s5AgTrpRcvrAddrType INTEGER,
|
|
s5AgTrpRcvrNetAddr OCTET STRING,
|
|
s5AgTrpRcvrComm OCTET STRING,
|
|
s5AgTrpRcvrAgeTime TimeIntervalSec
|
|
}
|
|
|
|
s5AgTrpRcvrIndx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the row in the table."
|
|
::= { s5AgTrpRcvrEntry 1 }
|
|
|
|
s5AgTrpRcvrStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
valid(2),
|
|
ignore(3),
|
|
delete(4),
|
|
create(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to create and
|
|
delete rows in the table and control
|
|
if they are used. The values
|
|
that can be written are:
|
|
valid(2)....makes an existing row
|
|
valid - can only be
|
|
written to change the
|
|
value from ignore(3)
|
|
ignore(3)...don't use this entry to
|
|
send traps to at this time
|
|
delete(4)...deletes the row
|
|
create(5)...creates a new row - only
|
|
value that can be used to
|
|
create a row in the table
|
|
|
|
If the row exists, then a SET with
|
|
value of create(5) returns error
|
|
'badValue'. Deleted rows go away
|
|
immediately. The following values
|
|
can be returned on reads:
|
|
other(1)....some other case
|
|
valid(2)....the row exists and is valid
|
|
ignore(3)...don't use this entry to
|
|
send traps to at this time"
|
|
::= { s5AgTrpRcvrEntry 2 }
|
|
|
|
s5AgTrpRcvrAddrType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ip(1),
|
|
ipx(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of address that is stored in
|
|
the object s5AgTrpRcvrNetAddr. The
|
|
value is:
|
|
ip(1)....IP address
|
|
ipx(2)...IPX address.
|
|
|
|
Note: When changing the value of this object
|
|
with an SNMP SET request, the SET PDU
|
|
must also specify a value for the
|
|
s5AgTrpRcvrNetAddr object."
|
|
::= { s5AgTrpRcvrEntry 3 }
|
|
|
|
s5AgTrpRcvrNetAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The network address (in network order) for
|
|
SNMP manager that is to receive the trap."
|
|
::= { s5AgTrpRcvrEntry 4 }
|
|
|
|
s5AgTrpRcvrComm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string to use."
|
|
::= { s5AgTrpRcvrEntry 5 }
|
|
|
|
s5AgTrpRcvrAgeTime OBJECT-TYPE
|
|
SYNTAX TimeIntervalSec
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time interval used to age entries out
|
|
of the trap receiver table. The default
|
|
value if not specified will be 0, or infinite,
|
|
never to be aged out."
|
|
DEFVAL { 0 }
|
|
::= { s5AgTrpRcvrEntry 6 }
|
|
|
|
|
|
-- Last Remote Login Management
|
|
|
|
s5AgRemoteLoginMgmt OBJECT IDENTIFIER ::= { s5AgentMgmt 5 }
|
|
|
|
s5AgRemoteLoginIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value indicates the last IP address remote login to this system. "
|
|
::= { s5AgRemoteLoginMgmt 1 }
|
|
|
|
s5AgRemoteLoginStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusUnknown (1),
|
|
successful (2),
|
|
passwordFail (3),
|
|
loginTimeout (4),
|
|
loginInactivityTimeout(5),
|
|
telnetSessionExisted (6),
|
|
nonAllowedIPaddr (7),
|
|
localConsoleBusy (8),
|
|
excessiveLoginFail (9),
|
|
accessPermissionOff (10),
|
|
loginLogout (11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value indicates the status of remote login to this system. "
|
|
::= { s5AgRemoteLoginMgmt 2 }
|
|
|
|
END
|