-- Compaq Computer Corporation Steam Agent Private MIB
|
|
--
|
|
-- MIB for release 2.2 of StorageWorks Enterprise Array Manager (STEAM) Daemon Agent.
|
|
--
|
|
-- Copyright (c) 1996,1997,1998-2001 Compaq Computer Corporation. All Rights Reserved.
|
|
-- Reproduction of this document is authorized on condition that the
|
|
-- foregoing notice is included.
|
|
--
|
|
-- This SNMP MIB Specification contains Compaq's confidential
|
|
-- and proprietary intellectual property. Compaq retains all title and
|
|
-- ownership in the Specification, including any revisions.
|
|
--
|
|
-- It is Compaq's intent to encourage the widespread use of this
|
|
-- Specification in connection with the management of storage subsystems using the
|
|
-- StorageWorks Command Console or Enterprise Storage Manager Graphical User Interface or
|
|
-- other SNMP management utilities. Compaq grants vendors, end-users,
|
|
-- and other interested parties a non-exclusive license to use this
|
|
-- Specification in connection with the management of Compaq StorageWorks
|
|
-- RAID Controller products.
|
|
--
|
|
-- This Specification is supplied AS IS, and Compaq makes no warranty,
|
|
-- either expressed or implied, as to the use, operation, condition, or
|
|
-- performance of the Specification.
|
|
--
|
|
--
|
|
-- StorageWorks Enterprise Array Manager (STEAM) Management Information Base (MIB)
|
|
--
|
|
-- iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dec(36)
|
|
-- ema(2) sysobjids(15) raidmanager(21)
|
|
--
|
|
-- :CPQ,DEV:
|
|
--
|
|
-- 16 Mar 2001 (dmc)
|
|
-- Added these developer's comments.
|
|
-- Changed references in above copyright statements from Digital to Compaq
|
|
-- Added value of unknown(3) to ssCacheBatteryStatus.
|
|
-- Added cacheBatteryStateUnknownTrap (22)
|
|
--
|
|
-- :CPQ,ENDDEV:
|
|
|
|
RAIDMANAGER-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM RFC1213-MIB;
|
|
|
|
dec OBJECT IDENTIFIER ::= { enterprises 36 }
|
|
ema OBJECT IDENTIFIER ::= { dec 2 }
|
|
sysobjids OBJECT IDENTIFIER ::= { ema 15 }
|
|
raidmanager OBJECT IDENTIFIER ::= { sysobjids 21 }
|
|
|
|
-- raidmanager MIB
|
|
agent OBJECT IDENTIFIER ::= { raidmanager 1 }
|
|
workstation OBJECT IDENTIFIER ::= { raidmanager 2 }
|
|
subsys OBJECT IDENTIFIER ::= { raidmanager 3 }
|
|
|
|
-- Agent Information Group
|
|
|
|
agManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the Enterprise Storage Manager Agent manufacturer."
|
|
|
|
::= { agent 1 }
|
|
|
|
agMajVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enterprise Storage Manager Agent Major Version Number (e.g., 3
|
|
for 3.0)."
|
|
|
|
::= { agent 2 }
|
|
|
|
agMinVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enterprise Storage Manager Agent Minor Version Number (e.g., 0
|
|
for 3.0)."
|
|
|
|
::= { agent 3 }
|
|
|
|
agHostName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Host System Network Name where the agent resides."
|
|
|
|
::= { agent 4 }
|
|
|
|
|
|
agEnterprise OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Enterprise ID subtree for Enterprise Storage Manager Agent MIB
|
|
is registered."
|
|
|
|
::= { agent 5 }
|
|
|
|
agDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Enterprise Array Storage Agent description."
|
|
|
|
::= { agent 6 }
|
|
|
|
|
|
-- Workstation Group
|
|
|
|
wsCPU OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The workstation CPU type (e.g., 80486)."
|
|
|
|
::= { workstation 1 }
|
|
|
|
wsComputerType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The workstation Computer type (e.g., PC/AT)."
|
|
|
|
::= { workstation 2 }
|
|
|
|
wsModel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The workstation model number."
|
|
|
|
::= { workstation 3 }
|
|
|
|
wsSubModel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The workstation submodel number."
|
|
|
|
::= { workstation 4 }
|
|
|
|
wsBiosVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The workstation BIOS Version."
|
|
|
|
::= { workstation 5 }
|
|
|
|
wsOS OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The workstation operating system name (e.g., WINNT)."
|
|
|
|
::= { workstation 6 }
|
|
|
|
wsOSMajVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The workstation OS major version number
|
|
(e.g., 3 for WINNT 3.51)."
|
|
|
|
::= { workstation 7 }
|
|
|
|
wsOSMinVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The workstation OS minor version number (e.g., 51 for
|
|
WINNT 3.51)."
|
|
|
|
::= { workstation 8 }
|
|
|
|
|
|
-- Subsystem Group
|
|
|
|
ssTotalSubSystems OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of subsystems presently serviced
|
|
by this agent."
|
|
|
|
::= { subsys 1 }
|
|
|
|
|
|
-- Subsystem Status Group
|
|
|
|
ssStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table holds the status information for
|
|
each subsystem."
|
|
|
|
::= { subsys 2 }
|
|
|
|
ssEntry OBJECT-TYPE
|
|
SYNTAX SsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subsystem information entry."
|
|
INDEX { ssEntryIndex }
|
|
|
|
::= { ssStatusTable 1 }
|
|
|
|
SsEntry ::=
|
|
SEQUENCE{
|
|
ssEntryIndex
|
|
INTEGER,
|
|
ssSubsysName
|
|
DisplayString,
|
|
ssOverallStatus
|
|
INTEGER,
|
|
ssDiskStatus
|
|
INTEGER,
|
|
ssPowerStatus
|
|
INTEGER,
|
|
ssFanStatus
|
|
INTEGER,
|
|
ssCacheBatteryStatus
|
|
INTEGER,
|
|
ssTemperatureStatus
|
|
INTEGER,
|
|
ssCommStatus
|
|
INTEGER,
|
|
ssEmuExtInputStatus
|
|
INTEGER,
|
|
ssEmuPresent
|
|
INTEGER,
|
|
ssController1Status
|
|
INTEGER,
|
|
ssController1SerNum
|
|
DisplayString,
|
|
ssController1RDAC
|
|
INTEGER,
|
|
ssController1Type
|
|
DisplayString,
|
|
ssController1ProdID
|
|
DisplayString,
|
|
ssController1FwRev
|
|
DisplayString,
|
|
ssController1HwRev
|
|
DisplayString,
|
|
ssController2Status
|
|
INTEGER,
|
|
ssController2SerNum
|
|
DisplayString,
|
|
ssController2RDAC
|
|
INTEGER,
|
|
ssController2Type
|
|
DisplayString,
|
|
ssController2ProdID
|
|
DisplayString,
|
|
ssController2FwRev
|
|
DisplayString,
|
|
ssController2HwRev
|
|
DisplayString,
|
|
ssUpsStatus
|
|
INTEGER,
|
|
ssLunStatus
|
|
INTEGER,
|
|
ssDiskName
|
|
DisplayString,
|
|
ssPowerSupplyLocation
|
|
DisplayString,
|
|
ssFanLocation
|
|
DisplayString,
|
|
ssCacheBatteryLocation
|
|
DisplayString,
|
|
ssTemperatureSensorLocation
|
|
DisplayString,
|
|
ssCabinetNumber
|
|
INTEGER,
|
|
ssLunName
|
|
DisplayString,
|
|
ssDiskPort
|
|
INTEGER,
|
|
ssDiskTarget
|
|
INTEGER
|
|
|
|
}
|
|
|
|
ssEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into ssStatusTable ."
|
|
|
|
::= { ssEntry 1 }
|
|
|
|
ssSubsysName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The local Subsystem Name."
|
|
|
|
::= { ssEntry 2 }
|
|
|
|
ssOverallStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
green(0),
|
|
yellow(1),
|
|
red(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the overall status of the
|
|
storage subsystem.
|
|
GREEN: Normal Operating Condition
|
|
YELLOW: Warning Condition
|
|
RED: Subsystem Communication Failure; No response to Agent requests."
|
|
|
|
::= { ssEntry 3 }
|
|
|
|
ssDiskStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allok(0),
|
|
atleast1failure(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the overall status for the
|
|
physical devices in the subsystem."
|
|
|
|
::= { ssEntry 4 }
|
|
|
|
ssPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allok(0),
|
|
atleast1failure(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the status for the
|
|
Power Supply system in the subsystem."
|
|
|
|
::= { ssEntry 5 }
|
|
|
|
ssFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allok(0),
|
|
atleast1failure(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the status for the
|
|
FAN system in the subsystem."
|
|
|
|
::= { ssEntry 6 }
|
|
|
|
|
|
ssCacheBatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normalcharge(0),
|
|
lowcharge(1),
|
|
failure(2),
|
|
unknown(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the status for the
|
|
Cache Battery in the subsystem. This status object is currently
|
|
non-functional but in place for future use."
|
|
|
|
::= { ssEntry 7 }
|
|
|
|
ssTemperatureStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
overtempcondition(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the status for the
|
|
Temperature in the subsystem."
|
|
|
|
::= { ssEntry 8 }
|
|
|
|
ssCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
communicationfailure(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the status for the
|
|
communication to the Primary Controller."
|
|
|
|
::= { ssEntry 9 }
|
|
|
|
ssEmuExtInputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allok(0),
|
|
atleast1failure(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the status for the
|
|
EMU external input."
|
|
|
|
::= { ssEntry 10 }
|
|
|
|
ssEmuPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
emunotpresent(0),
|
|
enupresent(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the availability of the
|
|
Environment Monitoring Unit for the storage subsystem."
|
|
|
|
::= { ssEntry 11 }
|
|
|
|
|
|
ssController1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
failed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the status for the
|
|
Primary Controller."
|
|
|
|
::= { ssEntry 12 }
|
|
|
|
ssController1SerNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Primary Controller's Serial Number."
|
|
|
|
::= { ssEntry 13 }
|
|
|
|
ssController1RDAC OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singlemode(0),
|
|
dualmode(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Primary Controller MODE."
|
|
|
|
::= { ssEntry 14 }
|
|
|
|
ssController1Type OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Primary Controller's Type indicator."
|
|
|
|
::= { ssEntry 15 }
|
|
|
|
ssController1ProdID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Primary Controller's Product ID."
|
|
|
|
::= { ssEntry 16 }
|
|
|
|
ssController1FwRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Primary Controller's Firmware Revision."
|
|
|
|
::= { ssEntry 17 }
|
|
|
|
ssController1HwRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Primary Controller's Hardware Revision."
|
|
|
|
::= { ssEntry 18 }
|
|
|
|
ssController2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
failed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the status for the
|
|
Secondary Controller."
|
|
|
|
::= { ssEntry 19 }
|
|
|
|
ssController2SerNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Secondary Controller's Serial Number."
|
|
|
|
::= { ssEntry 20 }
|
|
|
|
ssController2RDAC OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singlemode(0),
|
|
dualmode(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Secondary Controller MODE."
|
|
|
|
::= { ssEntry 21 }
|
|
|
|
ssController2Type OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Secondary Controller's Type indicator."
|
|
|
|
::= { ssEntry 22 }
|
|
|
|
ssController2ProdID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Secondary Controller's Product ID."
|
|
|
|
::= { ssEntry 23 }
|
|
|
|
ssController2FwRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Secondary Controller's Firmware Revision."
|
|
|
|
::= { ssEntry 24 }
|
|
|
|
ssController2HwRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Secondary Controller's Hardware Revision."
|
|
|
|
::= { ssEntry 25 }
|
|
|
|
ssUpsStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsnotpresent(0),
|
|
upspresent(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Uninterruptable Power Supply status (Currently for future use)."
|
|
|
|
::= { ssEntry 26 }
|
|
|
|
ssLunStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
good(0),
|
|
reduced(1),
|
|
reconstruct(2),
|
|
failure(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LUN status."
|
|
|
|
::= { ssEntry 27 }
|
|
|
|
ssDiskName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of disk with state change."
|
|
|
|
::= { ssEntry 28 }
|
|
|
|
ssPowerSupplyLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of power supply with state change."
|
|
|
|
::= { ssEntry 29 }
|
|
|
|
ssFanLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of fan with state change."
|
|
|
|
::= { ssEntry 30 }
|
|
|
|
ssCacheBatteryLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of controller cache battery with state change."
|
|
|
|
::= { ssEntry 31 }
|
|
|
|
ssTemperatureSensorLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of temperature sensor with state change."
|
|
|
|
::= { ssEntry 32 }
|
|
|
|
ssCabinetNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current cabinet number which has FRU state change."
|
|
|
|
::= { ssEntry 33 }
|
|
|
|
ssLunName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the LUN with a state change."
|
|
|
|
::= { ssEntry 34 }
|
|
|
|
ssDiskPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current disk channel number."
|
|
|
|
::= { ssEntry 35 }
|
|
|
|
ssDiskTarget OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current disk SCSI Target ID."
|
|
|
|
::= { ssEntry 36 }
|
|
|
|
-- Traps
|
|
|
|
diskFailureTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssDiskName,
|
|
ssCabinetNumber,
|
|
ssDiskPort,
|
|
ssDiskTarget
|
|
}
|
|
DESCRIPTION
|
|
"A disk drive has failed.
|
|
|
|
Details:
|
|
|
|
A disk device has failed.
|
|
|
|
User Action:
|
|
|
|
Replace the disk device."
|
|
|
|
--#TYPE "Disk device has failed"
|
|
--#SUMMARY "Disk %s in cabinet %d located on port %d; target %d on host: %s; subsystem: %s has failed."
|
|
--#ARGUMENTS {2,3,4,5,0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 1
|
|
|
|
diskInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssDiskName,
|
|
ssCabinetNumber,
|
|
ssDiskPort,
|
|
ssDiskTarget
|
|
|
|
}
|
|
DESCRIPTION
|
|
"A disk drive has recovered.
|
|
|
|
Details:
|
|
|
|
A disk device has recovered.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "Disk device has recovered"
|
|
--#SUMMARY "Disk %s in cabinet %d located on channel %d; target %d on host: %s; subsystem: %s has recovered."
|
|
--#ARGUMENTS {2,3,4,5,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 2
|
|
|
|
powerSupplyFailureTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCabinetNumber,
|
|
ssPowerSupplyLocation
|
|
}
|
|
DESCRIPTION
|
|
"One power supply has failed.
|
|
|
|
Details:
|
|
|
|
The power supply in the specified location has failed.
|
|
|
|
User Action:
|
|
|
|
Replace power supply."
|
|
|
|
--#TYPE "Power supply device has failed"
|
|
--#SUMMARY "Power supply %d in cabinet %d on host: %s; subsystem: %s has failed."
|
|
--#ARGUMENTS {3,2,0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 3
|
|
|
|
powerSupplyInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCabinetNumber,
|
|
ssPowerSupplyLocation
|
|
}
|
|
DESCRIPTION
|
|
"Power supply has recovered.
|
|
|
|
Details:
|
|
|
|
The power supply in the specified location has gone from BAD to good.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "Power supply device has recovered"
|
|
--#SUMMARY "Power supply %d in cabinet %d on host: %s; subsystem: %s has recovered."
|
|
--#ARGUMENTS {3,2,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 4
|
|
|
|
fanFailureTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCabinetNumber,
|
|
ssFanLocation
|
|
}
|
|
DESCRIPTION
|
|
"A fan has failed.
|
|
|
|
Details:
|
|
|
|
The fan in the specified location has failed.
|
|
|
|
User Action:
|
|
|
|
Replace fan."
|
|
|
|
--#TYPE "Fan device has failed"
|
|
--#SUMMARY "Fan %d in cabinet %d on host: %s; subsystem: %s has failed."
|
|
--#ARGUMENTS {3,2,0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 5
|
|
|
|
fanInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCabinetNumber,
|
|
ssFanLocation
|
|
}
|
|
DESCRIPTION
|
|
"A fan has recovered.
|
|
|
|
Details:
|
|
|
|
The fan in the specified location has recovered.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "Fan device has recovered"
|
|
--#SUMMARY "Fan %d in cabinet %d on host: %s; subsystem: %s has recovered."
|
|
--#ARGUMENTS {3,2,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 6
|
|
|
|
cacheBatteryFailureTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCacheBatteryLocation
|
|
}
|
|
DESCRIPTION
|
|
"A controller cache battery has failed.
|
|
|
|
Details:
|
|
|
|
The cache battery in specified location has failed.
|
|
|
|
User Action:
|
|
|
|
Replace cache battery or replenish charge."
|
|
|
|
--#TYPE "Cache battery device has failed"
|
|
--#SUMMARY "Cache Battery %d on host: %s; subsystem: %s has failed."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 7
|
|
|
|
cacheBatteryLowTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCacheBatteryLocation
|
|
}
|
|
DESCRIPTION
|
|
"A controller cache battery has LOW state.
|
|
|
|
Details:
|
|
|
|
The cache battery in specified location has LOW state.
|
|
|
|
User Action:
|
|
|
|
Replace cache battery or replenish charge."
|
|
|
|
--#TYPE "Cache battery device has LOW state"
|
|
--#SUMMARY "Cache Battery %d on host: %s; subsystem: %s has LOW state."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 8
|
|
|
|
cacheBatteryInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCacheBatteryLocation
|
|
}
|
|
DESCRIPTION
|
|
"A controller cache battery has good state.
|
|
|
|
Details:
|
|
|
|
The cache battery in specified location has good state.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "Cache battery device has good state"
|
|
--#SUMMARY "Cache Battery %d on host: %s; subsystem: %s has good state."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 9
|
|
|
|
temperatureOverThresholdTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCabinetNumber,
|
|
ssTemperatureSensorLocation
|
|
}
|
|
DESCRIPTION
|
|
"A temperature sensor has exceeded WARNING threshold limit.
|
|
|
|
Details:
|
|
|
|
The temperature sensor in the specified location has exceeded WARNING threshold limit.
|
|
|
|
User Action:
|
|
|
|
Lower environmental temperature or raise internal threshold limit depending upon application."
|
|
|
|
--#TYPE "Temperature device has exceeded WARNING threshold limit"
|
|
--#SUMMARY "Temperature Sensor %d in cabinet %d on host: %s; subsystem: %s has exceeded WARNING threshold limit."
|
|
--#ARGUMENTS {3,2,0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 10
|
|
|
|
temperatureInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCabinetNumber,
|
|
ssTemperatureSensorLocation
|
|
}
|
|
DESCRIPTION
|
|
"A temperature sensor indicates temperature below WARNING threshold limit.
|
|
|
|
Details:
|
|
|
|
The temperature sensor in the specified location indicates below WARNING threshold limit.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "Temperature device indicates below WARNING threshold limit"
|
|
--#SUMMARY "Temperature Sensor %d in cabinet %d on host: %s; subsystem: %s has recovered below WARNING threshold limit."
|
|
--#ARGUMENTS {3,2,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 11
|
|
|
|
communicationFailureTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName
|
|
}
|
|
DESCRIPTION
|
|
"Communication with the subsystem has failed.
|
|
|
|
Details:
|
|
|
|
The Agent lost communication with subsystem.
|
|
|
|
User Action:
|
|
|
|
Possible causes are data path interruption,
|
|
communication LUN failure,
|
|
2 or more power supplies failed,
|
|
2 or more fans failed,
|
|
temperature overlimit,
|
|
both controllers failed."
|
|
|
|
|
|
--#TYPE "Agent communication with subsystem lost."
|
|
--#SUMMARY "Agent on host: %s; subsystem: %s has lost communication with subsystem."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 1
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 12
|
|
|
|
communicationInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName
|
|
}
|
|
DESCRIPTION
|
|
"Communication with the subsystem has recovered.
|
|
|
|
Details:
|
|
|
|
The Agent recovered communication with subsystem.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
|
|
--#TYPE "Agent communication with subsystem recovered."
|
|
--#SUMMARY "Agent on host: %s; subsystem: %s has recovered communication with subsystem."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 13
|
|
|
|
controllerFailureTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName
|
|
}
|
|
DESCRIPTION
|
|
"The Secondary Controller in the subsytem has failed.
|
|
|
|
Details:
|
|
|
|
The Secondary Controller has failed.
|
|
|
|
User Action:
|
|
|
|
Replace controller. Possible causes are PCMCIA memory card ejected,
|
|
controller physically removed,
|
|
actual hardware failure."
|
|
|
|
--#TYPE "The Secondary Controller has failed."
|
|
--#SUMMARY "The Secondary Controller on host: %s; subsystem: %s has failed."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 14
|
|
|
|
controllerInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName
|
|
}
|
|
DESCRIPTION
|
|
"The Secondary Controller in the subsytem has recovered.
|
|
|
|
Details:
|
|
|
|
The Secondary Controller has recovered.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "The Secondary Controller has recovered."
|
|
--#SUMMARY "The Secondary Controller on host: %s; subsystem: %s has recovered."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 15
|
|
|
|
lunFailureTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssLunName
|
|
}
|
|
DESCRIPTION
|
|
"A LUN has failed.
|
|
|
|
Details:
|
|
|
|
The LUN has failed and is off-line.
|
|
|
|
User Action:
|
|
|
|
Possible cause is too many failed disk drives that make up the LUN,
|
|
the OS can no longer communicate with the LUN for other reasons."
|
|
|
|
--#TYPE "A LUN has failed."
|
|
--#SUMMARY "LUN %s on host: %s; subsystem: %s has failed."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 1
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 16
|
|
|
|
lunReconstructTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssLunName
|
|
}
|
|
DESCRIPTION
|
|
"A LUN has started the reconstruction process.
|
|
|
|
Details:
|
|
|
|
The LUN has started the reconstruction process but is available for normal use.
|
|
Possible causes are an available disk drive was created as a spare to be inserted into the set,
|
|
an existing spare was automatically added to the set for reconstruction upon failure of a member disk device.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "A LUN has started the reconstruction process."
|
|
--#SUMMARY "LUN %s on host: %s; subsystem: %s in now in reconstruct mode."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 17
|
|
|
|
lunReducedTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssLunName
|
|
}
|
|
DESCRIPTION
|
|
"A LUN has become degraded.
|
|
|
|
Details:
|
|
|
|
A LUN has become degraded due to a member disk device failure.
|
|
|
|
User Action:
|
|
|
|
Replace the failed disk device; add a spare to the system to cause a reconstruct."
|
|
|
|
--#TYPE "A LUN has become degraded."
|
|
--#SUMMARY "LUN %s on host: %s; subsystem: %s in now degraded."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 18
|
|
|
|
lunInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssLunName
|
|
}
|
|
DESCRIPTION
|
|
"A LUN has become optimal.
|
|
|
|
Details:
|
|
|
|
A LUN has become optimal due to a successful completion of the reconstruction process.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "A LUN has become optimal."
|
|
--#SUMMARY "LUN %s on host: %s; subsystem: %s in now optimal."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 19
|
|
|
|
externalInputFailureTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCabinetNumber
|
|
}
|
|
DESCRIPTION
|
|
"The user-defined External Input to the EMU indicates a failure.
|
|
|
|
Details:
|
|
|
|
The External Input to the EMU indicates a failure.
|
|
|
|
User Action:
|
|
|
|
If the state of the is FAILURE, then one of the user-defined external input
|
|
devices is reporting a problem."
|
|
|
|
--#TYPE "The External Input to the EMU indicates a failure."
|
|
--#SUMMARY "The External Input to the EMU in cabinet %d on host: %s; subsystem: %s indicates a failure."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#STATE DEGRADED
|
|
|
|
::= 20
|
|
|
|
externalInputInformationTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCabinetNumber
|
|
}
|
|
DESCRIPTION
|
|
"The user-defined External Input to the EMU indicates a recovery.
|
|
|
|
Details:
|
|
|
|
The External Input to the EMU indicates a recovery.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "The External Input to the EMU indicates a recovery."
|
|
--#SUMMARY "The External Input to the EMU in cabinet %d on host: %s; subsystem: %s indicates a recovery."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 21
|
|
|
|
cacheBatteryStateUnknownTrap TRAP-TYPE
|
|
ENTERPRISE raidmanager
|
|
VARIABLES { agHostName, -- or sysName,
|
|
ssSubsysName,
|
|
ssCacheBatteryLocation
|
|
}
|
|
DESCRIPTION
|
|
"A controller cache battery has unknown state.
|
|
|
|
Details:
|
|
|
|
The cache battery in specified location has an unknown state.
|
|
|
|
User Action:
|
|
|
|
None."
|
|
|
|
--#TYPE "Cache battery device has unknown state"
|
|
--#SUMMARY "Cache Battery %d on host: %s; subsystem: %s has unknown state."
|
|
--#ARGUMENTS {2,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22
|
|
|
|
END
|
|
|