mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-18 16:32:45 +00:00
744 lines
19 KiB
Plaintext
Executable File
744 lines
19 KiB
Plaintext
Executable File
|
|
-- ****************************************************************************
|
|
--
|
|
-- Integrity Server Trap SNMP MIB
|
|
-- Management Information Base for SNMP Network Management
|
|
--
|
|
--
|
|
-- Copyright 1993,2003-2004 Hewlett-Packard Development Company, L.P.
|
|
--
|
|
-- Hewlett-Packard Company shall not be liable for technical or
|
|
-- editorial errors or omissions contained herein. The information in
|
|
-- this document is provided "as is" without warranty of any kind and
|
|
-- is subject to change without notice. The warranties for HP products
|
|
-- are set forth in the express limited warranty statements
|
|
-- accompanying such products. Nothing herein should be construed as
|
|
-- constituting an additional warranty.
|
|
--
|
|
-- Confidential computer software. Valid license from HP required for
|
|
-- possession, use or copying. Consistent with FAR 12.211 and 12.212,
|
|
-- Commercial Computer Software, Computer Software Documentation, and
|
|
-- Technical Data for Commercial Items are licensed to the U.S.
|
|
-- Government under vendor's standard commercial license.
|
|
--
|
|
-- The Hewlett-Packard Enterprise number is 11.
|
|
-- The ASN.1 prefix to, and including the Hewlett-Packard Enterprise is:
|
|
-- 1.3.6.1.4.1.11
|
|
--
|
|
-- ****************************************************************************
|
|
--
|
|
--
|
|
-- * $Date: 11-24-2008$
|
|
-- * $Revision: 3.3$
|
|
--
|
|
-- IPF Trap MIB Revision
|
|
-- =========================
|
|
--
|
|
-- MIB Rev of 1.0 is for ORCA time frame
|
|
-- - This is the initial release of this MIB.
|
|
-- 2.0 - Event Data Now taken from new E0 data base
|
|
-- 2.1 - Add new Hondo events
|
|
-- 2.2 - Add new events for support of Eiger, Oly
|
|
-- 2.3 - Add new events for PFM, other new E0 events, and new 02 events
|
|
-- 2.4 - Add new events for E0 events, and 3 new temperature 02 events
|
|
-- 2.5 - Add new events for E0 events Rusa , ARc
|
|
-- 2.6 - Add new events for E0 events COD, HPVM
|
|
-- 2.7 - Add new events for E0 events RuSa-E, Merlion
|
|
-- 2.8 - Add new events for E0 events Tahiti
|
|
-- 2.9 - Add new events for E0 events Tahiti
|
|
-- 3.0 - Add new events for E0 events to support Windows Server 2008
|
|
-- 3.1 - Add new events for E0 events to support Bora Bora
|
|
-- 3.2 - Add new events for E0 events to support Bora Bora
|
|
-- 3.3 - Add new events for E0 events to support Bora Bora
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
HPIPF02TRAP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises FROM RFC1155-SMI
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215;
|
|
|
|
hp OBJECT IDENTIFIER ::= { enterprises 11 }
|
|
nm OBJECT IDENTIFIER ::= { hp 2 }
|
|
hpnsa OBJECT IDENTIFIER ::= { nm 23 }
|
|
hpIpfE0Events OBJECT IDENTIFIER ::= { hpnsa 35 }
|
|
hpIpf02Events OBJECT IDENTIFIER ::= { hpnsa 45 }
|
|
|
|
-- The following are objects defined for HP IPF Event Traps
|
|
|
|
hpIpfEvtDetailStr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This string provides a detailed description of the Event along with variable information."
|
|
::= { hpIpf02Events 1 }
|
|
|
|
|
|
-- Traps
|
|
|
|
hpTempHighWarning752 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the temperature sensors crossed its lower non-critical threshold."
|
|
|
|
--#SUMMARY "Temperature sensor crossed lower non-critical threshold"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 752
|
|
|
|
|
|
hpTempHighCritical753 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the temperature sensors crossed its upper critical threshold."
|
|
|
|
--#SUMMARY "A temperature inside the server went far outside the factory specified range"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 753
|
|
|
|
|
|
hpTempHighNonRecoverable754 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the temperature sensors crossed its upper non-recoverable threshold."
|
|
|
|
--#SUMMARY "Temperature sensor crossed upper non-recoverable threshold."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 754
|
|
|
|
|
|
hpTemperature4 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the temperature sensors crossed its upper non-critical threshold."
|
|
|
|
--#SUMMARY "A temperature inside the server has gone outside the factory specified range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 4
|
|
|
|
|
|
hpTemperature5 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the temperature sensors crossed its upper critical threshold."
|
|
|
|
--#SUMMARY "A temperature inside the server has gone far outside the factory specified range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 5
|
|
|
|
|
|
hpTemperature6 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the temperature sensors crossed its upper non-recoverable threshold."
|
|
|
|
--#SUMMARY "Temperature sensor crossed upper non-recoverable threshold"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 6
|
|
|
|
|
|
hpTemperature755 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"A temperature inside the server has gone outside the factory specified range."
|
|
|
|
--#SUMMARY "One of the temperature sensors crossed its upper non-critical threshold."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 755
|
|
|
|
|
|
hpTemperature756 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the temperature sensors crossed its upper critical threshold."
|
|
|
|
--#SUMMARY "A temperature inside the server went far outside the factory specified range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 756
|
|
|
|
|
|
hpEnvironment8 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the voltage sensors crossed its lower critical threshold."
|
|
|
|
--#SUMMARY "A measured voltage in the server has gone far outside the factory specified lower voltage range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 8
|
|
|
|
|
|
hpEnvironment9 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the voltage sensors crossed its lower non-recoverable threshold."
|
|
|
|
--#SUMMARY "Voltage sensor crossed lower non-recoverable threshold"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 9
|
|
|
|
|
|
hpEnvironment10 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the voltage sensors crossed its upper non-critical threshold."
|
|
|
|
--#SUMMARY "A measured voltage in the server has gone outside the factory specified upper voltage range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 10
|
|
|
|
|
|
hpEnvironment12 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage"
|
|
|
|
--#SUMMARY "Voltage sensor crossed upper non-recoverable threshold"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 12
|
|
|
|
|
|
hpEnvironment704 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Voltage fault - Check all boards with this voltage"
|
|
|
|
--#SUMMARY "Voltage insufficient"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 704
|
|
|
|
|
|
hpEnvironment728 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Voltage degraded to critical level from less severe - Check all boards with this voltage"
|
|
|
|
--#SUMMARY "Voltage reached critical level"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 728
|
|
|
|
|
|
hpEnvironment705 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage"
|
|
|
|
--#SUMMARY "Voltage reached critical level"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 705
|
|
|
|
|
|
hpEnvironment706 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage"
|
|
|
|
--#SUMMARY "Power Pod Voltage Fault"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 706
|
|
|
|
|
|
hpEnvironment707 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Voltage absent"
|
|
|
|
--#SUMMARY "Voltage absent"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 707
|
|
|
|
|
|
hpFan710 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Fan speed lags"
|
|
|
|
--#SUMMARY "Fan speed lags"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 710
|
|
|
|
|
|
hpChassis26 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"The chassis has been opened."
|
|
|
|
--#SUMMARY "The server's built-in sensors have detected an open chassis door."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 26
|
|
|
|
|
|
hpBmcFirmware730 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"The BMC firmware did not detect the system firmware boot."
|
|
|
|
--#SUMMARY "The BMC firmware did not detect the system firmware boot"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 730
|
|
|
|
|
|
hpRedundantPower720 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Power supply failed or disconnected"
|
|
|
|
--#SUMMARY "Power supply failure"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 720
|
|
|
|
|
|
hpRedundantPower732 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"The Power supply's sensors detect possible problems"
|
|
|
|
--#SUMMARY "The power supply sensors detect a possible problem"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 732
|
|
|
|
|
|
hpRedundantPower722 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Power supply AC lost"
|
|
|
|
--#SUMMARY "Power supply AC lost"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 722
|
|
|
|
|
|
hpRedundantPower757 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"The Power Supply AC voltage was lost or is out of range."
|
|
|
|
--#SUMMARY "The AC voltage to the power supply was lost or is out of range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 757
|
|
|
|
|
|
hpRedundantPower758 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"The AC voltage connected to the power supply is out of range."
|
|
|
|
--#SUMMARY "The power supply AC voltage is out of range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 758
|
|
|
|
|
|
hpPowerSupply731 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"A/C Failed, disconnected, or out of range"
|
|
|
|
--#SUMMARY "A/C Power failed, disconnected, or out of range"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 731
|
|
|
|
|
|
hpPowerSupply726 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"A/C Failed, disconnected, or out of range"
|
|
|
|
--#SUMMARY "Power failure in power supply"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 726
|
|
|
|
|
|
hpSystemHW733 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Cooling unit warning"
|
|
|
|
--#SUMMARY "Cooling unit warning"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 733
|
|
|
|
|
|
hpSystemHW734 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Cooling unit failure"
|
|
|
|
--#SUMMARY "Cooling unit failure"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 734
|
|
|
|
|
|
hpECCMemory518 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Uncorrectable multi-bit ECC error has occurred in memory module"
|
|
|
|
--#SUMMARY "Uncorrectable multi-bit ECC error has occurred"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 518
|
|
|
|
|
|
hpSystemFW700 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"System firmware error"
|
|
|
|
--#SUMMARY "Generic trap for Critical or Fatal type E0 event from system firmware"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 700
|
|
|
|
|
|
hpSystemHW744 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"System event log almost full"
|
|
|
|
--#SUMMARY "System event log almost full"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 744
|
|
|
|
|
|
hpSystemHW735 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"BMC entering special mode"
|
|
|
|
--#SUMMARY "BMC entering special mode"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 735
|
|
|
|
|
|
hpSystemHW729 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"System shut-down or reset caused by sensor reading. "
|
|
|
|
--#SUMMARY "System shut-down or reset caused by sensor reading"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 729
|
|
|
|
|
|
hpSystemHW745 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"TOC interrupt (crash dump)"
|
|
|
|
--#SUMMARY "TOC interrupt (crash dump)"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 745
|
|
|
|
|
|
hpSystemHW746 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"INIT Initiated"
|
|
|
|
--#SUMMARY "INIT Initiated"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 746
|
|
|
|
|
|
hpSystemHW751 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"PCI parity error detected"
|
|
|
|
--#SUMMARY "PCI parity error detected"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 751
|
|
|
|
|
|
hpSystemHW747 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"PCI system error detected"
|
|
|
|
--#SUMMARY "PCI system error detected"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 747
|
|
|
|
|
|
hpSystemFW699 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Machine Check Initiated"
|
|
|
|
--#SUMMARY "Machine Check Initiated"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 699
|
|
|
|
|
|
hpSystemHW113 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"A SCSI cable has been removed from the hot swap cage."
|
|
|
|
--#SUMMARY "Hot Swap Cage: SCSI cable removed"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 113
|
|
|
|
|
|
hpSystemHW748 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"OS run-time critical shutdown"
|
|
|
|
--#SUMMARY "OS run-time critical shutdown"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 748
|
|
|
|
|
|
hpSystemHW749 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"ACPI state S5 (soft-off, entered by override)"
|
|
|
|
--#SUMMARY "ACPI state S5 (soft-off, entered by override)"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 749
|
|
|
|
|
|
hpSystemHW736 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Watchdog timer expired - hard reset"
|
|
|
|
--#SUMMARY "Watchdog timer expired - hard reset"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 736
|
|
|
|
|
|
hpSystemHW737 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Watchdog timer expired - power-off"
|
|
|
|
--#SUMMARY "Watchdog timer expired - power-off"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 737
|
|
|
|
|
|
hpSystemHW738 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Watchdog timer expired - power-cycle"
|
|
|
|
--#SUMMARY "Watchdog timer expired - power-cycle"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 738
|
|
|
|
|
|
hpSystemHW739 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Missing FRU device"
|
|
|
|
--#SUMMARY "Missing FRU device"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 739
|
|
|
|
|
|
hpSystemHW740 TRAP-TYPE
|
|
ENTERPRISE hpIpf02Events
|
|
VARIABLES { hpIpfEvtDetailStr }
|
|
DESCRIPTION
|
|
"Missing Entity"
|
|
|
|
--#SUMMARY "Missing Entity"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 100
|
|
--#STATE OPERATIONAL
|
|
::= 740
|
|
|
|
|
|
|
|
|
|
END
|