snmp_mib_archive/cpqsanapp.cfg
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

117 lines
2.3 KiB
INI
Executable File

#-MIBFILE: cpqsanapp.mib
CPQSANAPP-MIB DEFINITIONS ::= BEGIN
DisplayString ::=
OCTET STRING
PhysAddress ::=
OCTET STRING
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
cpqSanAppliance OBJECT IDENTIFIER ::= { compaq 151 }
resourceMonitor OBJECT IDENTIFIER ::= { cpqSanAppliance 11 }
swSystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE(255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Fabric Element Name"
::= { resourceMonitor 1 }
swSystemType OBJECT-TYPE
SYNTAX INTEGER {
hsg80(1),
switch(2),
appliance(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Element Type Index"
::= { resourceMonitor 2 }
swEventName OBJECT-TYPE
SYNTAX DisplayString (SIZE(255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Event Name"
::= { resourceMonitor 3 }
swFailure OBJECT-TYPE
SYNTAX DisplayString (SIZE(255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Failure Description"
::= { resourceMonitor 4 }
swSequence OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Sequence Number"
::= { resourceMonitor 5 }
swFailureTrap TRAP-TYPE
ENTERPRISE resourceMonitor
VARIABLES { swSystemName, swSystemType, swEventName, swFailure, swSequence }
--#TYPE "Failure Event"
--#SUMMARY "Failure event detected element %d of Type %d sent notification %d %d."
--#ARGUMENTS {1, 2, 3, 4}
--#SEVERITY MAJOR
--#CATEGORY "SAN Appliance Events"
--#TIMEINDEX 99
DESCRIPTION "Failure event detected"
::= 1
swWarningTrap TRAP-TYPE
ENTERPRISE resourceMonitor
VARIABLES { swSystemName, swSystemType, swEventName, swFailure, swSequence }
--#TYPE "Warning Event"
--#SUMMARY "Warning event detected element %d of Type %d sent notification %d %d."
--#ARGUMENTS {1, 2, 3, 4}
--#SEVERITY MINOR
--#CATEGORY "SAN Appliance Events"
--#TIMEINDEX 99
DESCRIPTION "Warning event detected"
::= 2
swInformationTrap TRAP-TYPE
ENTERPRISE resourceMonitor
VARIABLES { swSystemName, swSystemType, swEventName, swFailure, swSequence }
--#TYPE "Information Event"
--#SUMMARY "Information event detected element %d of Type %d sent notification %d %d."
--#ARGUMENTS {1, 2, 3, 4}
--#SEVERITY INFORMATIONAL
--#CATEGORY "SAN Appliance Events"
--#TIMEINDEX 99
DESCRIPTION "Information event detected"
::= 4
END