#-MIBFILE: cpq-traps.mib
|
|
|
|
CPQ-TRAPS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
DisplayString ::=
|
|
OCTET STRING
|
|
|
|
PhysAddress ::=
|
|
OCTET STRING
|
|
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
compaq-proLiantBLeClassCG-proLiantBLpClassGbE OBJECT IDENTIFIER ::= { compaq 161 }
|
|
compaq-common-mgmt OBJECT IDENTIFIER ::= { compaq-proLiantBLeClassCG-proLiantBLpClassGbE 3 }
|
|
cpqRackInfo OBJECT IDENTIFIER ::= { compaq 22 }
|
|
cpqRackComponent OBJECT IDENTIFIER ::= { cpqRackInfo 2 }
|
|
cpqRackAsset OBJECT IDENTIFIER ::= { cpqRackComponent 2 }
|
|
cpqRackAssetTable OBJECT IDENTIFIER ::= { cpqRackAsset 1 }
|
|
cpqRackAssetEntry OBJECT IDENTIFIER ::= { cpqRackAssetTable 1 }
|
|
cpqRackUid OBJECT IDENTIFIER ::= { cpqRackAssetEntry 3 }
|
|
cpqRackEnclosure OBJECT IDENTIFIER ::= { cpqRackComponent 3 }
|
|
cpqRackCommonEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 1 }
|
|
cpqRackCommonEnclosureTable OBJECT IDENTIFIER ::= { cpqRackCommonEnclosure 1 }
|
|
cpqRackCommonEnclosureEntry OBJECT IDENTIFIER ::= { cpqRackCommonEnclosureTable 1 }
|
|
cpqRackCommonEnclosureSerialNum OBJECT IDENTIFIER ::= { cpqRackCommonEnclosureEntry 7 }
|
|
cpqRackNetwork OBJECT IDENTIFIER ::= { cpqRackComponent 6 }
|
|
cpqRackNetConnector OBJECT IDENTIFIER ::= { cpqRackNetwork 1 }
|
|
cpqRackNetConnectorTable OBJECT IDENTIFIER ::= { cpqRackNetConnector 1 }
|
|
cpqRackNetConnectorEntry OBJECT IDENTIFIER ::= { cpqRackNetConnectorTable 1 }
|
|
cpqRackNetConnectorSerialNum OBJECT IDENTIFIER ::= { cpqRackNetConnectorEntry 7 }
|
|
cpqRackName OBJECT IDENTIFIER ::= { cpqRackAssetEntry 2 }
|
|
cpqRackCommonEnclosureName OBJECT IDENTIFIER ::= { cpqRackCommonEnclosureEntry 9 }
|
|
cpqRackNetConnectorName OBJECT IDENTIFIER ::= { cpqRackNetConnectorEntry 5 }
|
|
cpqRackNetConnectorLocation OBJECT IDENTIFIER ::= { cpqRackNetConnectorEntry 12 }
|
|
cpqRackNetConnectorFWRev OBJECT IDENTIFIER ::= { cpqRackNetConnectorEntry 10 }
|
|
cpqRackNetConnectorSparePartNumber OBJECT IDENTIFIER ::= { cpqRackNetConnectorEntry 9 }
|
|
agentGeneralMgmt OBJECT IDENTIFIER ::= { compaq-common-mgmt 1 }
|
|
agentBasicConfig OBJECT IDENTIFIER ::= { agentGeneralMgmt 2 }
|
|
agentBscSwFileTable OBJECT IDENTIFIER ::= { agentBasicConfig 1 }
|
|
agentBscSwFileEntry OBJECT IDENTIFIER ::= { agentBscSwFileTable 1 }
|
|
agentBscSwFileAddr OBJECT IDENTIFIER ::= { agentBscSwFileEntry 3 }
|
|
agentBscSwFile OBJECT IDENTIFIER ::= { agentBscSwFileEntry 5 }
|
|
agentBscSwFileLoadType OBJECT IDENTIFIER ::= { agentBscSwFileEntry 7 }
|
|
agentBscSwFileStatus OBJECT IDENTIFIER ::= { agentBscSwFileEntry 11 }
|
|
agentSNTP OBJECT IDENTIFIER ::= { agentGeneralMgmt 7 }
|
|
agentSNTPServer1IPAddr OBJECT IDENTIFIER ::= { agentSNTP 3 }
|
|
agentSNTPServer2IPAddr OBJECT IDENTIFIER ::= { agentSNTP 4 }
|
|
agentSwitchCommonMgmt OBJECT IDENTIFIER ::= { compaq-common-mgmt 3 }
|
|
agentSwitchFan OBJECT IDENTIFIER ::= { agentSwitchCommonMgmt 3 }
|
|
agentSwitchFanTable OBJECT IDENTIFIER ::= { agentSwitchFan 1 }
|
|
agentSwitchFanEntry OBJECT IDENTIFIER ::= { agentSwitchFanTable 1 }
|
|
agentSwitchFanIndex OBJECT IDENTIFIER ::= { agentSwitchFanEntry 1 }
|
|
agentSwitchFanCondition OBJECT IDENTIFIER ::= { agentSwitchFanEntry 2 }
|
|
agentSwitchTempSensor OBJECT IDENTIFIER ::= { agentSwitchCommonMgmt 4 }
|
|
agentSwitchTempSensorTable OBJECT IDENTIFIER ::= { agentSwitchTempSensor 1 }
|
|
agentSwitchTempSensorEntry OBJECT IDENTIFIER ::= { agentSwitchTempSensorTable 1 }
|
|
agentSwitchTempSensorIndex OBJECT IDENTIFIER ::= { agentSwitchTempSensorEntry 1 }
|
|
agentSwitchTempSensorCurrent OBJECT IDENTIFIER ::= { agentSwitchTempSensorEntry 2 }
|
|
agentSwitchTempSensorThreshold OBJECT IDENTIFIER ::= { agentSwitchTempSensorEntry 3 }
|
|
agentSwitchTempSensorCondition OBJECT IDENTIFIER ::= { agentSwitchTempSensorEntry 4 }
|
|
agentSwitchTempSensorTempType OBJECT IDENTIFIER ::= { agentSwitchTempSensorEntry 5 }
|
|
agentSwitchPowerSupply OBJECT IDENTIFIER ::= { agentSwitchCommonMgmt 2 }
|
|
agentSwitchPowerSupplyTable OBJECT IDENTIFIER ::= { agentSwitchPowerSupply 1 }
|
|
agentSwitchPowerSupplyEntry OBJECT IDENTIFIER ::= { agentSwitchPowerSupplyTable 1 }
|
|
agentSwitchPowerSupplyMaxPwrOutput OBJECT IDENTIFIER ::= { agentSwitchPowerSupplyEntry 2 }
|
|
agentSwitchPowerSupplyCurPwrOutput OBJECT IDENTIFIER ::= { agentSwitchPowerSupplyEntry 3 }
|
|
agentSwitchPowerSupplyIntakeTemp OBJECT IDENTIFIER ::= { agentSwitchPowerSupplyEntry 4 }
|
|
agentSwitchPowerSupplyExhaustTemp OBJECT IDENTIFIER ::= { agentSwitchPowerSupplyEntry 5 }
|
|
agentSwitchPowerSupplyStatus OBJECT IDENTIFIER ::= { agentSwitchPowerSupplyEntry 6 }
|
|
agentSwitchPowerSupplyInputLineStatus OBJECT IDENTIFIER ::= { agentSwitchPowerSupplyEntry 7 }
|
|
agentSwitchPowerSupplyCondition OBJECT IDENTIFIER ::= { agentSwitchPowerSupplyEntry 8 }
|
|
agentSwitchCube OBJECT IDENTIFIER ::= { agentSwitchCommonMgmt 1 }
|
|
agentSwitchCubeTable OBJECT IDENTIFIER ::= { agentSwitchCube 1 }
|
|
agentSwitchCubeEntry OBJECT IDENTIFIER ::= { agentSwitchCubeTable 1 }
|
|
agentSwitchCubeType OBJECT IDENTIFIER ::= { agentSwitchCubeEntry 1 }
|
|
agentSwitchCubeSpareName OBJECT IDENTIFIER ::= { agentSwitchCubeEntry 2 }
|
|
agentSwitchCubeSparePartNumber OBJECT IDENTIFIER ::= { agentSwitchCubeEntry 3 }
|
|
entityMIB OBJECT IDENTIFIER ::= { mib-2 47 }
|
|
|
|
entityMIBTraps OBJECT IDENTIFIER ::= { entityMIB 2 }
|
|
|
|
entityMIBTrapPrefix OBJECT IDENTIFIER ::= { entityMIBTraps 0 }
|
|
|
|
switchFanFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, agentSwitchFanIndex, agentSwitchFanCondition }
|
|
--#SEVERITY CRITICAL
|
|
--#TYPE "The switch fan has failed"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch fan has failed."
|
|
::= 161006
|
|
|
|
|
|
switchPostSuccess TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber }
|
|
--#SEVERITY MINOR
|
|
--#TYPE "Successfully completed POST"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch has successfully completed POST."
|
|
::= 161011
|
|
|
|
|
|
switchTFTPTransferFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, agentBscSwFileAddr, agentBscSwFile, agentBscSwFileLoadType }
|
|
--#SEVERITY MINOR
|
|
--#TYPE "Failed a TFTP transfer"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch has failed a TFTP transfer."
|
|
::= 161004
|
|
|
|
|
|
switchSNTPServiceUnavailable TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, agentSNTPServer1IPAddr, agentSNTPServer2IPAddr }
|
|
--#SEVERITY MINOR
|
|
--#TYPE "SNTP service unavailable"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "A SNTP Server was configured, but no SNTP servers were found. This trap is sent once if SNTP is enabled, a SNTP server is configured, and a SNTP server could not be contacted for 10minutes from the start time. The start time will be defined as when both SNTP was enabled and a SNTP server was configured or when a SNTP server was contacted successfully."
|
|
::= 161015
|
|
|
|
|
|
switchFanOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, agentSwitchFanIndex, agentSwitchFanCondition }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TYPE "The switch fan has returned to normal operation"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch fan has returned to normal operation."
|
|
::= 161007
|
|
|
|
|
|
entConfigChange TRAP-TYPE
|
|
ENTERPRISE entityMIBTrapPrefix
|
|
ENTERPRISE entityMIBTrapPrefix
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TYPE "Configuration Change Event"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "An entConfigChange notification is generated when the value of entLastChangeTime changes. It can be utilized by an NMS to trigger logical/physical entity table maintenance polls. An agent should not generate more than one entConfigChange 'notification-event' in a given time interval (five seconds is the suggested default). A 'notification-event' is the transmission of a single trap or inform PDU to a list of notification destinations. If additional configuration changes occur within the throttling period, then notification-events for these changes should be suppressed by the agent until the current throttling period expires. At the end of a throttling period, one notification-event should be generated if any configuration changes occurred since the start of the throttling period. In such a case, another throttling period is started right away. An NMS should periodically check the value of entLastChangeTime to detect any missed entConfigChange notification-events, e.g., due to throttling or transmission loss."
|
|
::= 1
|
|
|
|
|
|
switchLoginFailure TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation }
|
|
--#SEVERITY MINOR
|
|
--#TYPE "Rejected a login attempt"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch has rejected a login attempt."
|
|
::= 161012
|
|
|
|
|
|
switchTempSensorFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, agentSwitchTempSensorIndex, agentSwitchTempSensorCurrent, agentSwitchTempSensorThreshold, agentSwitchTempSensorCondition, agentSwitchTempSensorTempType }
|
|
--#SEVERITY CRITICAL
|
|
--#TYPE "Over-temperature condition"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch temperature sensor indicates an over-temperature condition."
|
|
::= 161009
|
|
|
|
|
|
switchTempSensorDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, agentSwitchTempSensorIndex, agentSwitchTempSensorCurrent, agentSwitchTempSensorThreshold, agentSwitchTempSensorCondition, agentSwitchTempSensorTempType }
|
|
--#SEVERITY MAJOR
|
|
--#TYPE "High temperature condidtion"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch temperature sensor indicates a high temperature condidtion."
|
|
::= 161008
|
|
|
|
|
|
switchTFTPTransferSucceeded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, agentBscSwFileAddr, agentBscSwFile, agentBscSwFileLoadType }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TYPE "Successfully completed a TFTP transfer"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch has successfully completed a TFTP transfer."
|
|
::= 161003
|
|
|
|
|
|
switchCubeTypeChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, agentSwitchCubeType, agentSwitchCubeSpareName, agentSwitchCubeSparePartNumber }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TYPE "Switch cube type changed"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "Trap for connection different cube type. Customer has changed the cube type since the last boot. "
|
|
::= 161014
|
|
|
|
|
|
switchFirmwareTransferred TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, agentBscSwFileAddr, agentBscSwFile, agentBscSwFileLoadType, cpqRackNetConnectorFWRev }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TYPE "Successfully transferred a firmware image"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch has successfully transferred a firmware image."
|
|
::= 161001
|
|
|
|
|
|
switchLocationChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TYPE "Switch location change"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch location has changed. The new location is defined in the variables. The trap will be sent out on the next boot"
|
|
::= 161013
|
|
|
|
|
|
switchFileInvalid TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, agentBscSwFileAddr, agentBscSwFile, agentBscSwFileLoadType, agentBscSwFileStatus }
|
|
--#SEVERITY MINOR
|
|
--#TYPE "Invalid firmware or configuration image downloaded"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "Invalid firmware or configuration image downloaded."
|
|
::= 161005
|
|
|
|
|
|
switchConfigFileTransferred TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, agentBscSwFileAddr, agentBscSwFile, agentBscSwFileLoadType }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TYPE "Successfully transferred a configuration file"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch has successfully transferred a configuration file."
|
|
::= 161002
|
|
|
|
|
|
switchTempSensorOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackNetConnectorSerialNum, cpqRackName, cpqRackCommonEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, agentSwitchTempSensorIndex, agentSwitchTempSensorCurrent, agentSwitchTempSensorThreshold, agentSwitchTempSensorCondition, agentSwitchTempSensorTempType }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TYPE "Returned to Normal Temperature"
|
|
--#CATEGORY "ProLiant BL p-Class GbE Interconnect Switch Events"
|
|
DESCRIPTION "The switch temperature sensor indicates temperature has returned to normal."
|
|
::= 161010
|
|
|
|
|
|
END
|