snmp_mib_archive/CISCO-WAN-FR-X21-MIB.my
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

993 lines
27 KiB
Plaintext

-- *****************************************************************
-- ciscoWanFrX21LineMIB
--
-- September 2002, Subra Hegde
--
-- Copyright (c) 2002 by cisco Systems, Inc.
-- All rights reserved.
-- ****************************************************************
CISCO-WAN-FR-X21-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
x21,
frPortCnfX21PortGrp
FROM BASIS-MIB
ciscoWan FROM CISCOWAN-SMI;
ciscoWanFrX21MIB MODULE-IDENTITY
LAST-UPDATED "200209190000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-wanatm@cisco.com"
DESCRIPTION
"The MIB module to configure X.21/HSSI physical
and logical interfaces.
This MIB module also contains alarm configuration
of X.21 interfaces.
Terminologies Used:
HSSI : High Speed Serial Interface. The HSSI defines
both electrical and physical interfaces on
DTE and DCE devices. It operates at the physical
layer of the OSI reference model. This provides
high-speed data communication over WAN and LAN links."
REVISION "200209190000Z"
DESCRIPTION
"Initial version of the MIB.
The content of this MIB was originally available
in CISCO-WAN-AXIPOP-MIB defined using SMIv1.
The applicable objects from CISCO-WAN-AXIPOP-MIB
are defined using SMIv2 in this MIB."
::= { ciscoWan 49 }
x21CnfGrp OBJECT IDENTIFIER ::= { x21 1 }
x21AlmCnfGrp OBJECT IDENTIFIER ::= { x21 2 }
x21AlmGrp OBJECT IDENTIFIER ::= { x21 3 }
-- **********************************************************************
-- X.21 Config Group
--
-- This group contains X.21 line configuration table
-- **********************************************************************
x21CnfGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF X21CnfGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The X21 Configuration table. The table size is
given by the value of x21LineNumofValidEntries."
::= { x21CnfGrp 1 }
x21CnfGrpEntry OBJECT-TYPE
SYNTAX X21CnfGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the X21 Configuration table."
INDEX { x21LineNum }
::= { x21CnfGrpTable 1 }
X21CnfGrpEntry ::=
SEQUENCE {
x21LineNum Integer32,
x21LineEnable INTEGER,
x21LineType INTEGER,
x21LineRate INTEGER,
x21LineLoopbackCommand INTEGER,
x21LineSendCode INTEGER,
x21LineLoopbackCodeDetection INTEGER,
x21ConnectorType INTEGER,
x21InvertClock INTEGER,
x21LineInterfaceType INTEGER,
x21ClkFrequencyThreshold Integer32,
serialLineRate Integer32,
serialLineRateVariation Integer32
}
x21LineNum OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the identifier of a X.21 interface.
FRSM-HS2/HS2B-HSSI supports a range from 1 to 2.
FRSM-HS2B-12IN1 supports a range from 1 to 8."
::= { x21CnfGrpEntry 1 }
x21LineEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2),
modify (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable disables, enables or modifies a line
1 - disable
2 - enable
3 - modify
Default is enable.
"
::= { x21CnfGrpEntry 2 }
x21LineType OBJECT-TYPE
SYNTAX INTEGER {
dte (1),
dce (2),
dteST (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the type X21 line type.
The line-type affects the clock -- the DCE device
always provides the clock and DTE accepts it.
dteST is only applicable to V.35 interfaces
Default is DTE.
"
::= { x21CnfGrpEntry 3 }
x21LineRate OBJECT-TYPE
SYNTAX INTEGER {
r48Kbps(1),
r56Kbps(2),
r64Kbps(3),
r112Kbps(4),
r128Kbps(5),
r168Kbps(6),
r192Kbps(7),
r224Kbps(8),
r256Kbps(9),
r280Kbps(10),
r320Kbps(11),
r336Kbps(12),
r384Kbps(13),
r392Kbps(14),
r448Kbps(15),
r512Kbps(16),
r768Kbps(17),
r1024Kbps(18),
r1536Kbps(19),
r1544Kbps(20),
r1792Kbps(21),
r1920Kbps(22),
r1984Kbps(23),
r2048Kbps(24),
r3097Kbps(25),
r3157Kbps(26),
r4096Kbps(27),
r4645Kbps(28),
r4736Kbps(29),
r6195Kbps(30),
r6315Kbps(31),
r7744Kbps(32),
r7899Kbps(33),
r8192Kbps(34),
r9289Kbps(35),
r9472Kbps(36),
r10240Kbps(37),
r10890Kbps(38),
r11060Kbps(39),
r12390Kbps(40),
r12630Kbps(41),
r13900Kbps(42),
r14220Kbps(43),
r14340Kbps(44),
r15490Kbps(45),
r15800Kbps(46),
r16380Kbps(47),
r20030Kbps(48),
r24990Kbps(49),
r52Mbps(50),
-- FRSM_VHS added for frsm_vhs
r17370Kbps(51),
r18950Kbps(52),
r20530Kbps(53),
r22100Kbps(54),
r23680Kbps(55),
--
-- n*T1 rates. Added for FRSM_VHS
-- note that 1.544Kbps is already enumerated above
--
r3088Kbps(56),
r4632Kbps(57),
r6176Kbps(58),
r7720Kbps(59),
r9264Kbps(60),
r10808Kbps(61),
r12352Kbps(62),
r13896Kbps(63),
r15440Kbps(64),
r16984Kbps(65),
r18528Kbps(66),
r20072Kbps(67),
r21616Kbps(68),
r23160Kbps(69),
r24704Kbps(70),
r26248Kbps(71),
r27792Kbps(72),
r29336Kbps(73),
r30880Kbps(74),
r32424Kbps(75),
r33968Kbps(76),
r35512Kbps(77),
r37056Kbps(78),
r38600Kbps(79),
r40144Kbps(80),
r41688Kbps(81),
r43232Kbps(82),
r44776Kbps(83),
r46320Kbps(84),
r47864Kbps(85),
r49408Kbps(86),
r50952Kbps(87),
--
-- n*E1 rates. Added for FRSM_VHS.
--
r6144Kbps(88),
r12288Kbps(89),
r14336Kbps(90),
r16384Kbps(91),
r18432Kbps(92),
r20480Kbps(93),
r22528Kbps(94),
r24576Kbps(95),
r26624Kbps(96),
r28672Kbps(97),
r30720Kbps(98),
r32768Kbps(99),
r34816Kbps(100),
r36864Kbps(101),
r38912Kbps(102),
r40960Kbps(103),
r43008Kbps(104),
r45056Kbps(105),
r47104Kbps(106),
r49152Kbps(107),
r51200Kbps(108)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable configures the X.21/HSSI/V.35 line-rate.
Note that enumerations 51 through 108 are supported
only by FRSM-HS2/HS2B card.
default is r48Kbps on FRSM-HS2B-12IN1
default is r52Mbps on FRSM-HS2/HS2B-HSSI
"
::= { x21CnfGrpEntry 4 }
x21LineLoopbackCommand OBJECT-TYPE
SYNTAX INTEGER {
x21NoLoop (1),
x21DiagnosticMetallicLoop (2),
x21DiagnosticFrontcardLoop (3),
x21RemoteLoop (4),
v35MetallicLoop (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the loopback state
x21NoLoop
Not in the loopback state. Normal traffic can be sent
x21DiagnosticMetallicLoop
Loopbacks the line on the back-card towards the Network.
x21DiagnosticFrontcardLoop
Loopbacks the line on the frontcard toward the Network.
x21RemoteLoop
The remote NTU is in the loop back mode.
In this state, the FRSM-HS1 is sending the loopback
code to remote NTU.
Default is x21NoLoop.
Note: Before going into one of the loopbacks the state
should be x21NoLoop.
"
::= { x21CnfGrpEntry 5 }
x21LineSendCode OBJECT-TYPE
SYNTAX INTEGER {
x21NoCode (1),
x21SendLoopACode (2),
x21SendLoopBCode (3),
x21SendLocalLoopCode (4),
x21SendRemoteLoopCode (5),
x21SendUnLoopCode (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates what type of code is
being sent across the X.21/HSSI interface by the
device. The values mean:
x21NoCode: No loopback.
x21SendLoopACode:
Start sending Loop A code. Valid only if
the backcard is HSSI and the line-type is DTE.
This command loops the line module of the remote
device.
x21SendLoopBCode:
Start sending Loop B code. Valid only if the
backcard is HSSI and the line-type is DTE.
This command loops the digital section of the
remote device.
x21SendLocalLoopCode:
Start sending CCITT X.21 Loopback Type 3 code.
This is valid only if the backcard is X.21 type.
x21SendRemoteLoopCode:
Start sending CCITT X.21 Loopback Type 2 code.
This is valid only if the backcard is X.21 type.
x21SendUnLoopCode:
Sending a loopback termination request.
Valid for both HSSI and X.21 lines.
To execute any of the loop-codes the x21LineLoopbackCommand
should be set to x21RemoteLoop.
Once the x21SendUnLoopCode succeeds the x21LineLoopbackCommand
would transition back to x21NoLoop state.
Default is x21NoCode."
::= { x21CnfGrpEntry 6 }
x21LineLoopbackCodeDetection OBJECT-TYPE
SYNTAX INTEGER {
codeDetectDisabled (1),
codeDetectEnabled (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable detection of line Loopback Codes.
The loopback detection is implemented only in HSSI
DCE mode.
Default is codeDetectDisabled."
::= { x21CnfGrpEntry 7 }
x21ConnectorType OBJECT-TYPE
SYNTAX INTEGER {
x21Backcard (1),
hssiBackcard (2),
v35Backcard (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"back card type
This object is not used by FRSM-HS2/HS2B
"
::= { x21CnfGrpEntry 8 }
x21InvertClock OBJECT-TYPE
SYNTAX INTEGER {
nonInvertedAndNotLooped (1),
invertedAndNotLooped (2),
nonInvertedAndLooped (3),
invertedAndLooped (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures two options:
a) To invert the clock sent by HS1/HS2B with the
TX data or not.
b) If DCE,to expect the receive clock looped back
from DTE or not.
If DTE,to loop back the receive clock from DCE or not.
nonInvertedAndNotLooped(1)- a)=dont invert,
b)=dont expect rcv clock/
dont loop rcv clock
invertedAndNotLooped(2) - a)=invert,
b)=dont expect rcv clock/
dont loop rcv clock
nonInvertedAndLooped(3) - a)=dont invert,
b)=expect rcv clock/
loop rcv clock
invertedAndLooped(4) - a)=invert,
b)=expect rcv clock/
loop rcv clock
Enums 1 and 2 are applicable for X.21/HSSI/V.35 interfaces.
Enums 3 and 4 are applicable only for V.35.
Default for X.21/HSSI is nonInvertedAndNotLooped(1)
Default for V.35 is nonInvertedAndLooped(3)
This object is not used by FRSM-HS2/FRSM-HS2B-HSSI
This object is used by FRSM-HS2B-12IN1 and default
values are nonInvertedAndNotLooped(1) for X.21,
nonInvertedAndLooped(3) for V.35."
::= { x21CnfGrpEntry 9 }
x21LineInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
hssi(1),
x21 (2),
v35 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates serial interface type.
Default is hssi(1).
This object is not is configurable in FRSM-HS2
and FRSM-HS2B-HSSI. It will be set to hssi(1) by
default for these cards
This object is configurable in FRSM-H2B-12IN1.
Default is v35(3)."
::= { x21CnfGrpEntry 10}
x21ClkFrequencyThreshold OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates user configurable percentage of
clock frequency, which is used by DTE clock monitoring
to declare clock rate out of bound alarm. This object
is valid only for X.21/v.35/HSSI DTE interfaces.
This object is supported by FRSM-HS2 and FRSM-HS2/B"
DEFVAL { 3 }
::= { x21CnfGrpEntry 11}
serialLineRate OBJECT-TYPE
SYNTAX Integer32 (48000..51840000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line rate for X.21/HSSI/V.35 interfaces
in bps. This object is supported only by
FRSM-HS2/B card, only multiples of
1000 are accepted.
Default is 48Kbps for X.21/V.35 interfaces
and 51840Kbps for HSSI interface."
::= { x21CnfGrpEntry 12}
serialLineRateVariation OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates line rate variation of
HSSI/X.21/V.35 DCE interfaces in ppm (parts
per million). i.e. clock generated from DCE hardware
interface = (serialLineRate +/- (serialLineRateVariation
* 10^6)/ serialLineRate)
This object is supported only by FRSM-HS2/B card "
::= { x21CnfGrpEntry 13}
x21LineNumofValidEntries OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of X.21/HSSI configuration entries
(regardless of their current configuration) in
the x21ConfigTable table."
::= { x21CnfGrp 2 }
-- ******************************************************************
--
--
-- LOGICAL PORT CONFIG Group
--
--
-- ******************************************************************
frPortCnfX21PortGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrPortCnfX21PortGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The config table is for X.21/HSSI logical port interface
"
::= { frPortCnfX21PortGrp 1 }
frPortCnfX21PortGrpEntry OBJECT-TYPE
SYNTAX FrPortCnfX21PortGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry for logical port."
INDEX { x21portNum }
::= { frPortCnfX21PortGrpTable 1 }
FrPortCnfX21PortGrpEntry ::=
SEQUENCE {
x21portNum Integer32,
x21portLineNum Integer32,
x21portRowStatus INTEGER,
x21portFlagsBetweenFrames Integer32,
x21portEqueueServiceRatio Integer32,
x21portSpeed Integer32,
x21portAdmin INTEGER,
x21portType INTEGER,
x21portSvcStatus INTEGER,
x21portSvcInUse INTEGER,
x21portSvcShareLcn INTEGER,
x21portSvcLcnLow Integer32,
x21portSvcLcnHigh Integer32,
x21portSvcDlciLow Integer32,
x21portSvcDlciHigh Integer32,
x21portDeleteSvcs INTEGER,
x21portIngrSvcBandW Integer32,
x21portEgrSvcBandW Integer32
}
x21portNum OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is logical port number.
The HSSI backcard can support upto 3 ports.
The X.21 back card can support 4 logical ports."
::= { frPortCnfX21PortGrpEntry 1}
x21portLineNum OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This represents the line number.
On FRSM-HS1 the HSSI can support 3 lines
and X.21 4 lines."
::= { frPortCnfX21PortGrpEntry 2}
x21portRowStatus OBJECT-TYPE
SYNTAX INTEGER {
add(1),
del(2),
mod(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable adds, deletes, or modifies the port
1- add
2 - delete
3 - modify
Default is add."
::= { frPortCnfX21PortGrpEntry 3 }
x21portFlagsBetweenFrames OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of flags transmitted between two consecutive
HDLC frames.
Default is 1 flag."
::= { frPortCnfX21PortGrpEntry 4 }
x21portEqueueServiceRatio OBJECT-TYPE
SYNTAX Integer32 (1..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of times queue 1 is serviced
for every time queue 2 is serviced.
Default is 1."
::= { frPortCnfX21PortGrpEntry 5 }
x21portSpeed OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port speed in kbps. At present it is same
as line speed."
::= { frPortCnfX21PortGrpEntry 6 }
x21portAdmin OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
write-Only(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for administratively
changing the status of the port.
Up/down used to up and down the port.
Default is the up state."
::= { frPortCnfX21PortGrpEntry 7 }
x21portType OBJECT-TYPE
SYNTAX INTEGER {
frame-relay (1),
frFUNI (2),
frame-forward (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This represents port type. The processing of the
frames depends on the type of the port."
::= { frPortCnfX21PortGrpEntry 8 }
x21portSvcStatus OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This represents SVC status."
::= { frPortCnfX21PortGrpEntry 9 }
x21portSvcInUse OBJECT-TYPE
SYNTAX INTEGER {
not-use (1),
in-use (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This represents port SVC in use."
::= { frPortCnfX21PortGrpEntry 10 }
x21portSvcShareLcn OBJECT-TYPE
SYNTAX INTEGER {
port-based(1),
card-based(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents port type."
::= { frPortCnfX21PortGrpEntry 11 }
x21portSvcLcnLow OBJECT-TYPE
SYNTAX Integer32 (16..271)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents low end of reserved LCN for SVC."
::= { frPortCnfX21PortGrpEntry 12 }
x21portSvcLcnHigh OBJECT-TYPE
SYNTAX Integer32 (16..271)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents high end of reserved LCN for SVC."
::= { frPortCnfX21PortGrpEntry 13 }
x21portSvcDlciLow OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents low end of reserved DLCI for SVC."
::= { frPortCnfX21PortGrpEntry 14 }
x21portSvcDlciHigh OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents high end of reserved DLCI for SVC."
::= { frPortCnfX21PortGrpEntry 15 }
x21portDeleteSvcs OBJECT-TYPE
SYNTAX INTEGER {
delete(1),
other(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 1 indicates that all the SVC
connections on the given port has to be deleted."
::= { frPortCnfX21PortGrpEntry 16 }
x21portIngrSvcBandW OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents Ingress Bandwidth reserve for SVC."
::= { frPortCnfX21PortGrpEntry 17 }
x21portEgrSvcBandW OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents Egress Bandwidth reserve for SVC."
::= { frPortCnfX21PortGrpEntry 18 }
-- *********************************************************************
-- x21AlmConfig group
--
-- This group contains X.21/HSSI line alarm configuration table
--
-- *********************************************************************
x21AlmCnfGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF X21AlmCnfGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FRSM-HS1/HS2 interface alarm configuration table."
::= { x21AlmCnfGrp 1 }
x21AlmCnfGrpEntry OBJECT-TYPE
SYNTAX X21AlmCnfGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the X.21/HSSI Alarm
Configuration table."
INDEX { x21AlmCnfLineNum }
::= { x21AlmCnfGrpTable 1 }
X21AlmCnfGrpEntry ::=
SEQUENCE {
x21AlmCnfLineNum Integer32,
x21Severity INTEGER
}
x21AlmCnfLineNum OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"X.21/HSSI line number.
FRSM-HS2/HS2B-HSSI supports a range from 1 to 2.
FRSM-HS2B-12IN1 supports a range from 1 to 8."
::= { x21AlmCnfGrpEntry 1 }
x21Severity OBJECT-TYPE
SYNTAX INTEGER {
minor(1),
major(2),
dontcare(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable is used to setup the severity of
LOS(Loss of Signal) or clock mismatch alarm.
Whenever the above condition arises, the
FRSM-HS1/HS2/HS2B will send the alarm with
appropriate status."
::= { x21AlmCnfGrpEntry 2 }
-- *********************************************************************
--
-- X.21/HSSI Alarm Group
--
-- This group contains X.21/HSSI line alarm table
--
-- *********************************************************************
x21AlmGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF X21AlmGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The X.21/HSSI interface alarm configuration table."
::= { x21AlmGrp 1 }
x21AlmGrpEntry OBJECT-TYPE
SYNTAX X21AlmGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the X21 Alarm table"
INDEX { x21AlmLineNum }
::= { x21AlmGrpTable 1 }
X21AlmGrpEntry ::=
SEQUENCE {
x21AlmLineNum Integer32,
x21LineAlarmState Integer32,
x21LineEIAStatus Integer32,
x21AlarmClrButton INTEGER
}
x21AlmLineNum OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the identifier (line number) of a
X.21/HSSI interface. The value for this object must
be same as the value of x21LineNum."
::= { x21AlmGrpEntry 1 }
x21LineAlarmState OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is a bitmap of the X21 Line ALarms
on the FRSM-HS1. A value of zero indicates no alarms.
Itemized below are the individual bits:
BitPosition Alarm
----------- -----
0 C/I signal is OFF (also used to indicate LOS)
1 Clock rate mismatch (used in DTE mode)
2 Internal Loopback (diagnostic loopback)
3 HSSI Local LoopA (line is in loopback)
4 HSSI Local LoopB (line is in loopback)
5 Remote Loopback (line is transmitting loopcodes)
6 For V35 DTE mode, DCD and CTS both are inactive
7 For V35 DCE mode, RTS is inactive
8 No cable attached to V35 backcard
9 Wrong cable attached to V35 backcard
If all the bit-states are 0s:
- line is not in alarm, or
- line not in loopback, or
- line is transmitting any loopback codes.
"
::= { x21AlmGrpEntry 2 }
x21LineEIAStatus OBJECT-TYPE
SYNTAX Integer32 (0..'10'h)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of X.21/HSSI lines:
0x01 -- c-lead high
0x02 -- i-lead high
0x04 -- LC-lead high (valid only for HSSI DCE mode)."
::= { x21AlmGrpEntry 3 }
x21AlarmClrButton OBJECT-TYPE
SYNTAX INTEGER {
noaction (1),
clear (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable is used to clear all the
alarms for the line.
1 = No action
2 = Clear alarm."
::= { x21AlmGrpEntry 4 }
-- conformance information
cwfX21MIBConformance OBJECT IDENTIFIER ::= { ciscoWanFrX21MIB 2 }
cwfX21MIBGroups OBJECT IDENTIFIER ::= { cwfX21MIBConformance 1 }
cwfX21MIBCompliances OBJECT IDENTIFIER ::= { cwfX21MIBConformance 2 }
-- compliance statements
cwfX21Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for objects related
to Frame Relay Ports."
MODULE
MANDATORY-GROUPS {
ciscoWanFrX21LineGroup,
ciscoWanFrX21PortGroup,
ciscoWanFrX21AlarmConfGroup,
ciscoWanFrX21AlarmGroup
}
::= { cwfX21MIBCompliances 1 }
ciscoWanFrX21PortGroup OBJECT-GROUP
OBJECTS {
x21portNum,
x21portLineNum,
x21portRowStatus,
x21portFlagsBetweenFrames,
x21portEqueueServiceRatio,
x21portSpeed,
x21portAdmin,
x21portType,
x21portSvcStatus,
x21portSvcInUse,
x21portSvcShareLcn,
x21portSvcLcnLow,
x21portSvcLcnHigh,
x21portSvcDlciLow,
x21portSvcDlciHigh,
x21portDeleteSvcs,
x21portIngrSvcBandW,
x21portEgrSvcBandW
}
STATUS current
DESCRIPTION
"The collection of objects which are applicable
for X21 ports in frame relay."
::= { cwfX21MIBGroups 1 }
ciscoWanFrX21LineGroup OBJECT-GROUP
OBJECTS {
x21LineNum,
x21LineEnable,
x21LineType,
x21LineRate,
x21LineLoopbackCommand,
x21LineSendCode,
x21LineLoopbackCodeDetection,
x21ConnectorType,
x21InvertClock,
x21LineInterfaceType,
x21ClkFrequencyThreshold,
serialLineRate,
serialLineRateVariation,
x21LineNumofValidEntries
}
STATUS current
DESCRIPTION
"The collection of objects which are related
to x21 lines."
::= { cwfX21MIBGroups 2 }
ciscoWanFrX21AlarmConfGroup OBJECT-GROUP
OBJECTS {
x21AlmCnfLineNum,
x21Severity
}
STATUS current
DESCRIPTION
"The collection of objects which are related
to x21 lines."
::= { cwfX21MIBGroups 3 }
ciscoWanFrX21AlarmGroup OBJECT-GROUP
OBJECTS {
x21AlmLineNum,
x21LineAlarmState,
x21LineEIAStatus,
x21AlarmClrButton
}
STATUS current
DESCRIPTION
"The collection of objects which are related
to x21 lines."
::= { cwfX21MIBGroups 4 }
END