-- CISCO-RF-SUPPLEMENTAL-MIB.my
--
-- Created January 2001, Fred Frazer
--
-- Copyright (c) 2001, 2004 by Cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
CISCO-RF-SUPPLEMENTAL-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Counter32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
NOTIFICATION-GROUP,
OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION,
TruthValue,
DateAndTime
FROM SNMPv2-TC
ciscoMgmt
FROM CISCO-SMI
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
ConfigCopyState
FROM CISCO-CONFIG-COPY-MIB
PhysicalIndex
FROM ENTITY-MIB;
ciscoRfSupMIB MODULE-IDENTITY
LAST-UPDATED "200405270000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Cisco Systems Customer Service
Postal: 170 West Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-rf-mib@cisco.com"
DESCRIPTION
"This MIB was designed to complement the CISCO-RF-MIB by
providing additional optional status and configuration control
for redundant CPU platforms.
However, the MIB should also be applicable to redundant
platforms which don't use the RF Redundancy Framework software
since it makes no direct references to any CISCO-RF-MIB objects
or textual conventions and no direct reference to any RF
states, RF events or internal information.
Glossary of terms used in this document:
Active - A redundant CPU which is actively controlling
the system.
Running configuration - The runtime configuration of a
system which reflects current configured
hardware or software settings. Runtime
configuration which is not stored in
non-volatile memory may be lost if the system
loses power.
Standby - A redundant CPU which is not currently
controlling the system, but which can take
over control if the Active CPU fails.
Startup configuration - A copy of system configuration
stored in non-volatile memory which can be
applied following a system powerup.
For platforms where all runtime configuration
is automatically stored in a non-volatile
manner, the running and startup configurations
are always identical.
Switchover - The transfer of control from one CPU to a
redundant CPU.
Sync - The mirroring (or synchronizing) of system
state, configuration, statistics or other
information from the Active CPU to a Standby
CPU to allow it to maintain full system control
following a switchover."
REVISION "200405270000Z"
DESCRIPTION
"Added the following scalar object to the cRfSupSystem
subgroup:
cRfSupSysIfCounterSync"
REVISION "200403040000Z"
DESCRIPTION
"Two notifications ciscoRfSupTimeChangeEvent and
ciscoRfSupTimeZoneChangeEvent have been added.
cRfSupNotificationsEnabled has been added to control
the above objects."
REVISION "200103160000Z"
DESCRIPTION
"The initial release of this MIB."
::= { ciscoMgmt 198 }
--
-- Textual conventions
--
RfSupSyncAdminState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value which indicates the administrative
state to allow user control of the syncing of database
information from an Active unit to the Standby unit(s)."
SYNTAX INTEGER {
enableAutoSync(1),
disableAutoSync(2)
}
RfSupSyncOperState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value which indicates the operational state
for the syncing of database information from an Active unit
to the Standby unit(s)."
SYNTAX INTEGER {
inSync(1),
lastUpdateFailed(2), -- last sync failed, reason unknown or
-- unspecified.
commDown(3), -- All communication down to Standby
syncDisabled(4), -- Disabled by user configuration
noStandbyPresent(5)
}
--
-- OBJECT IDENTIFIER assignments for various groups
--
ciscoRfSupMIBNotifs OBJECT IDENTIFIER ::= { ciscoRfSupMIB 0 }
ciscoRfSupMIBObjects OBJECT IDENTIFIER ::= { ciscoRfSupMIB 1 }
--
-- sub-groups
--
cRfSupSystem OBJECT IDENTIFIER ::= { ciscoRfSupMIBObjects 1 }
cRfSupCpu OBJECT IDENTIFIER ::= { ciscoRfSupMIBObjects 2 }
cRfSupAction OBJECT IDENTIFIER ::= { ciscoRfSupMIBObjects 3 }
--
-- The following "System" sub-group definitions are made up of
-- objects that monitor or control aspects of the combined redundant
-- system.
--
cRfSupSysAvailableStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when this system began providing
uninterrupted operation. This includes the time while either
redundant unit was Active, but may also include brief intervals
during switchover where the new Active unit was operational,
but not yet reachable for network management purposes. It may
also include intervals where no Standby unit was offering
protection, as long as the Active unit was still operational.
It normally changes only if an unprotected system restart
occurs or if a Standby unit was forced to take over before
the initial database sync was completed.
However, it may also change if the system's Time of Day clock
is changed or adjusted. This object will be inaccurate if the
system's Time of Day clock has not been set accurately. However,
it should be implemented in such a way that when the system's
Time of Day clock is adjusted to an accurate setting,
cRfSupSysAvailableStartTime will also adjust to show the
accurate available start time."
::= { cRfSupSystem 1 }
cRfSupSysSwitchoverTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when the last CPU switchover took place.
This object will remain uninstantiated if no switchovers have
taken place since the current Active CPU was initialized."
::= { cRfSupSystem 2 }
cRfSupSysSwitchovers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that switchovers have occurred since
cRfSupSysAvailableStartTime.
This object will remain uninstantiated if no switchovers have
taken place since the current Active CPU was initialized
or if a Standby unit was forced to take over before the
initial database sync was completed."
::= { cRfSupSystem 3 }
cRfSupSysRunningConfigSyncTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when the running configuration was last
successfully synced from the current Active unit to the
Standby unit.
This object will remain uninstantiated if no sync has yet
taken place since the current Active CPU was initialized
or if a Standby unit was forced to take over before the
initial database sync was completed.
Since automatic running configuration syncs are event driven
and can be disabled by configuration, this time doesn't
directly indicate whether Standby software reflects the
running configuration of the Active unit.
Instead, see the cRfSupSysRunningConfigOper object to
determine whether Standby running configuration is in
sync with the Active CPU."
::= { cRfSupSystem 4 }
cRfSupSysRunningConfigAdmin OBJECT-TYPE
SYNTAX RfSupSyncAdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables automatic running configuration syncs only.
Doesn't affect other types of sync activity. If set to the
default value enableAutoSync, the Active unit will send the
full current running configuration following any operation
that changes the running configuration.
Setting disableAutoSync may be useful for some maintenance
and debugging operations."
::= { cRfSupSystem 5 }
cRfSupSysRunningConfigOper OBJECT-TYPE
SYNTAX RfSupSyncOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of running configuration syncs.
When the value inSync is returned, it indicates that the
Standby running configuration is being kept actively in sync
with the Active unit."
::= { cRfSupSystem 6 }
cRfSupSysStartupConfigSyncTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when the startup configuration was last
successfully synced from the current Active unit to the
Standby unit(s).
This object will remain uninstantiated if no sync has yet
taken place since the current Active CPU was initialized
or if a Standby unit was forced to take over before the
initial database sync was completed.
For platforms where running configuration is always stored
in a non-volatile manner, this object should be identical
to cRfSupSysRunningConfigSyncTime.
Since automatic startup configuration syncs are event driven
and may be disabled by configuration, this time doesn't
directly reflect whether Standby startup configuration is
in sync with the Active unit.
Instead, see the cRfSupSysStartupConfigOper object to
determine whether Standby startup configuration is in sync
with the Active unit."
::= { cRfSupSystem 7 }
cRfSupSysStartupConfigAdmin OBJECT-TYPE
SYNTAX RfSupSyncAdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables automatic startup configuration syncs only.
Doesn't affect other types of sync activity. If set to the
default value enableAutoSync, the Active unit will send the
full current startup configuration to the Standby unit(s)
after any operation that changes the startup configuration
in non-volatile memory.
This object is not applicable to systems where running
configuration is always stored in non-volatile memory.
Setting disableAutoSync may be useful for some maintenance
and debugging operations."
::= { cRfSupSystem 8 }
cRfSupSysStartupConfigOper OBJECT-TYPE
SYNTAX RfSupSyncOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of startup configuration syncs.
When the value inSync is returned, it indicates that the
Standby startup configuration is being kept actively in sync
with the Active unit."
::= { cRfSupSystem 9 }
cRfSupSysBootImageSyncTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when the boot image memory was last
successfully synced from the current Active unit to the
Standby unit(s).
This object will remain uninstantiated if no sync has yet
taken place since the current Active CPU was initialized
or if a Standby unit was forced to take over before the
initial database sync was completed.
Since automatic boot image memory syncs are event driven
and may be disabled by configuration, this time doesn't
directly reflect whether Standby boot image memory is
in sync with the Active unit.
Instead, see the cRfSupSysBootImageOper object to determine
whether Standby boot image memory is in sync with the Active
unit."
::= { cRfSupSystem 10 }
cRfSupSysBootImageAdmin OBJECT-TYPE
SYNTAX RfSupSyncAdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables automatic boot image memory syncs only.
Doesn't affect other types of sync activity. If set to the
default value enableAutoSync, the Active unit will send the
full current boot image memory to the Standby unit(s) after
any operation that affects the boot image.
This object is not applicable for systems that don't
support automatic boot image memory mirroring.
Setting disableAutoSync is necessary during software upgrades
for the case where the boot image memory space is too small to
simultaneously hold both the old and new images."
::= { cRfSupSystem 11 }
cRfSupSysBootImageOper OBJECT-TYPE
SYNTAX RfSupSyncOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of boot image memory syncs.
When the value inSync is returned, it indicates that
Standby boot image memory is being actively mirrored from
the Active unit."
::= { cRfSupSystem 12 }
cRfSupSysStandbyBootFile OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allow Standby unit(s) to automatically load a boot image
which differs from the image specified for the Active unit.
The string should be of the form <device>:<filename>.
Specifying a null value indicates that Standby unit(s) should
not use a different image than the Active unit.
This is used during software upgrade/downgrade procedures,
for platforms that support automatic syncs for boot image
memory."
::= { cRfSupSystem 13 }
cRfSupNotificationsEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies whether ciscoRfSupTimeChangeEvent,
ciscoRfSupTimeZoneChangeEvent notifications shall be sent
when the system's clock or time zone is changed causing
a change in the values of cRfSupSysAvailableStartTime or
cRfSupSysSwitchoverTime objects.
Notifications will be sent only if this object is
set to 'true'."
DEFVAL { false }
::= { cRfSupSystem 14 }
cRfSupSysIfCounterSync OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the synchronization of Interface
Statistics information from Active CPU to the
Standby CPU.
When this object is set to 'true', synchronization is
enabled. When this object is set to 'false',
synchronization is disabled."
::= { cRfSupSystem 15 }
--
-- The following "Cpu" sub-group definitions are made up of
-- objects that monitor or control aspects of the individual
-- redundant units.
--
cRfSupCpuTable OBJECT-TYPE
SYNTAX SEQUENCE OF CRfSupCpuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing redundancy-related information for
individual CPU cards."
::= { cRfSupCpu 1 }
cRfSupCpuEntry OBJECT-TYPE
SYNTAX CRfSupCpuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information which can differ for each of the redundant
CPU units in the system."
INDEX { cRfSupCpuUniqueIndex }
::= { cRfSupCpuTable 1 }
CRfSupCpuEntry ::=
SEQUENCE {
cRfSupCpuUniqueIndex PhysicalIndex,
cRfSupCpuActiveSeverity INTEGER,
cRfSupCpuInitTime DateAndTime
}
cRfSupCpuUniqueIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table index which always has a unique platform-assigned
value for each physical redundant unit within a particular
system.
This index should refer to a particular physical unit
rather than a logically Active or Standby unit."
::= { cRfSupCpuEntry 1 }
cRfSupCpuActiveSeverity OBJECT-TYPE
SYNTAX INTEGER {
nonFaulty(0),
nonTrafficAffectingFault(1),
partialTrafficAffectingFault(2),
fullyTrafficAffectingFault(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fault severity of a redundant unit, as calculated by
software. The value zero represents a good unit with no
detected faults. Higher values represent progressively more
serious faults. If it's not possible to determine any current
or prior severity information about a unit, the value unknown
should be returned.
Unlike some severity definitions, cRfSupCpuActiveSeverity
should not be downgraded when it switches from being Active.
The severity for a faulty Standby unit should correspond to
the system impact it would have if it were made to be the
Active unit, assuming the severity can be determined while
Standby.
The severity can be affected by either hardware or software
faults with the CPU itself. It can also be affected by faults
which prevent this CPU from interacting with one or more other
system components (such as linecards), even when the actual
faulty Field Replaceable Unit (FRU) is not the CPU itself.
As a minimum, the nonFaulty and fullyTrafficAffectingFault
values should be supported on any platform supporting this
object. Support of the other severity values is preferred,
but optional."
::= { cRfSupCpuEntry 2 }
cRfSupCpuInitTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when this redundant unit was last
initialized.
If the unit started out in the Standby state, this will also
include the time while running as Standby."
::= { cRfSupCpuEntry 3 }
--
-- The following "Action" sub-group definitions are made up of objects
-- that are associated with the execution of system actions.
--
cRfSupActionManualSync OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
runningConfig(2),
startupConfig(3),
bootImage(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable is set to invoke a one-time manual copy of the
specified information type from the Active to one or more
Standby units.
When read, this object returns the last command written
or noAction if no action has been written to the Active unit
since it was initialized. The value noAction can not be used
in a write request.
The result of the last requested action can be determined
by reading the value of cRfSupActionLastSyncResult. The value
of the cRfSupActionManualSync object can not be changed until
the cRfSupActionLastSyncResult transitions to the successful
or failed state."
::= { cRfSupAction 1 }
cRfSupActionLastSyncResult OBJECT-TYPE
SYNTAX ConfigCopyState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the result of the last Manual Sync action request.
This object is instantiated only after the
cRfSupActionManualSync object has been set to a value other
than noAction."
::= { cRfSupAction 2 }
--
-- Notifications
--
ciscoRfSupTimeChangeEvent NOTIFICATION-TYPE
OBJECTS {
cRfSupSysAvailableStartTime,
cRfSupSysSwitchoverTime}
STATUS current
DESCRIPTION
"This notification is sent on the event of system clock
modification causing a change in the values of
cRfSupSysAvailableStartTime or cRfSupSysSwitchoverTime objects,
if cRfSupNotificationsEnabled object has value 'true'.
If the system clock change is a result of a time zone change
event,this notification will not be sent."
::= { ciscoRfSupMIBNotifs 1 }
ciscoRfSupTimeZoneChangeEvent NOTIFICATION-TYPE
OBJECTS {
cRfSupSysAvailableStartTime,
cRfSupSysSwitchoverTime}
STATUS current
DESCRIPTION
"This notification is sent on the event of system time zone
modification causing a change in the values of
cRfSupSysAvailableStartTime or cRfSupSysSwitchoverTime objects,
if cRfSupNotificationsEnabled object has value 'true'."
::= { ciscoRfSupMIBNotifs 2 }
--
-- Conformance
--
ciscoRfSupMibConformance OBJECT IDENTIFIER
::= { ciscoRfSupMIB 2 }
ciscoRfSupMibCompliances OBJECT IDENTIFIER
::= { ciscoRfSupMibConformance 1 }
ciscoRfSupMibGroups OBJECT IDENTIFIER
::= { ciscoRfSupMibConformance 2 }
--
-- compliance statements
--
ciscoRfSupMibCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement the
Cisco RF SUPPLEMENTAL MIB.
Note: Platforms which implement the Cisco RF MIB are
not required to support the RF SUPPLEMENTAL MIB."
MODULE -- this module
MANDATORY-GROUPS {
ciscoRfSupSysGroup,
ciscoRfSupActionGroup
}
-- Conditionally mandatory groups
GROUP ciscoRfSupCpuGroup
DESCRIPTION
"The ciscoRfSupCpuGroup is mandatory only for platforms
supporting the ENTITY-MIB."
::= { ciscoRfSupMibCompliances 1 }
ciscoRfSupMibComplianceRev1 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement the
Cisco RF SUPPLEMENTAL MIB.
Note: Platforms which implement the Cisco RF MIB are
not required to support the RF SUPPLEMENTAL MIB. "
MODULE -- this module
MANDATORY-GROUPS {
ciscoRfSupSysGroup,
ciscoRfSupActionGroup
}
-- Conditionally mandatory groups
GROUP ciscoRfSupCpuGroup
DESCRIPTION
"The ciscoRfSupCpuGroup is mandatory only for platforms
supporting the ENTITY-MIB."
GROUP ciscoRfSupSysOptionalGroup
DESCRIPTION
"The ciscoRfSupSysOptionalGroup is mandatory only for
systems supporting ciscoRfSupNotifGroup."
::= { ciscoRfSupMibCompliances 2 }
ciscoRfSupMibComplianceRev2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement the
Cisco RF SUPPLEMENTAL MIB.
Note: Platforms which implement the Cisco RF MIB are
not required to support the RF SUPPLEMENTAL MIB. "
MODULE -- this module
MANDATORY-GROUPS {
ciscoRfSupSysGroup,
ciscoRfSupActionGroup
}
-- Conditionally mandatory groups
GROUP ciscoRfSupCpuGroup
DESCRIPTION
"The ciscoRfSupCpuGroup is mandatory only for platforms
supporting the ENTITY-MIB."
GROUP ciscoRfSupSysOptionalGroup
DESCRIPTION
"The ciscoRfSupSysOptionalGroup is mandatory only for
systems supporting ciscoRfSupNotifGroup."
-- Optional groups
GROUP ciscoRfSupNotifGroup
DESCRIPTION
"This group is optional on platforms supporting the
CISCO-RF-SUPPLEMENTAL-MIB."
GROUP ciscoRfSupSysOptionalSyncGroup
DESCRIPTION
"This group is optional on platforms supporting the
the CISCO-RF-SUPPLEMENTAL-MIB."
::= { ciscoRfSupMibCompliances 3 }
--
-- Units of conformance
--
ciscoRfSupSysGroup OBJECT-GROUP
OBJECTS {
cRfSupSysAvailableStartTime,
cRfSupSysSwitchoverTime,
cRfSupSysSwitchovers,
cRfSupSysRunningConfigSyncTime,
cRfSupSysRunningConfigAdmin,
cRfSupSysRunningConfigOper,
cRfSupSysStartupConfigSyncTime,
cRfSupSysStartupConfigAdmin,
cRfSupSysStartupConfigOper,
cRfSupSysBootImageSyncTime,
cRfSupSysBootImageAdmin,
cRfSupSysBootImageOper,
cRfSupSysStandbyBootFile
}
STATUS current
DESCRIPTION
"The collection of RF SUPPLEMENTAL system-wide objects."
::= { ciscoRfSupMibGroups 1 }
ciscoRfSupCpuGroup OBJECT-GROUP
OBJECTS {
cRfSupCpuActiveSeverity,
cRfSupCpuInitTime
}
STATUS current
DESCRIPTION
"The collection of RF SUPPLEMENTAL per-CPU objects."
::= { ciscoRfSupMibGroups 2 }
ciscoRfSupActionGroup OBJECT-GROUP
OBJECTS {
cRfSupActionManualSync,
cRfSupActionLastSyncResult
}
STATUS current
DESCRIPTION
"The collection of RF SUPPLEMENTAL execution actions."
::= { ciscoRfSupMibGroups 3 }
ciscoRfSupSysOptionalGroup OBJECT-GROUP
OBJECTS {
cRfSupNotificationsEnabled
}
STATUS current
DESCRIPTION
"The collection of optional RF SUPPLEMENTAL system-wide
objects."
::= { ciscoRfSupMibGroups 4 }
ciscoRfSupNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS {
ciscoRfSupTimeChangeEvent,
ciscoRfSupTimeZoneChangeEvent
}
STATUS current
DESCRIPTION
"The collection of optional notifications issued on
system time/time zone modifications."
::= { ciscoRfSupMibGroups 5 }
ciscoRfSupSysOptionalSyncGroup OBJECT-GROUP
OBJECTS {
cRfSupSysIfCounterSync
}
STATUS current
DESCRIPTION
"The collection of optional RF SUPPLEMENTAL system wide
objects that control and monitor the synchronization of
information between the redundant system units."
::= { ciscoRfSupMibGroups 6 }
END