-- SECTION 1: Top Level Definitions
S5-TOKENRING-MIB DEFINITIONS ::= BEGIN
-- 5000 Token Ring MIB Release 1.2.1
-- Revision 04/05/95
-- Copyright 1995 Bay Networks, Inc.
-- All rights reserved.
-- This SynOptics SNMP Management Information Base Specification
-- (Specification) embodies Bay Networks' confidential and
-- proprietary intellectual property. Bay Networks retains all
-- title and ownership in the Specification, including any
-- revisions.
-- This Specification is supplied "AS IS," and Bay Networks makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
-- Imports
IMPORTS
Counter, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
s5Tok
FROM S5-ROOT-MIB
MacAddress, TimeIntervalSec, TimeIntervalHrd, SrcIndx
FROM S5-TCS-MIB;
-- Token Ring Groups
-- Configuration
s5TrCfg OBJECT IDENTIFIER ::= { s5Tok 1 }
-- Statistics
s5TrStat OBJECT IDENTIFIER ::= { s5Tok 2 }
-- Ring and Station
s5TrRing OBJECT IDENTIFIER ::= { s5Tok 3 }
-- Test Path Group
s5TrTest OBJECT IDENTIFIER ::= { s5Tok 4 }
-- SECTION 2: Ring and Station Information
-- Ring Info table
s5TrRingInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5TrRingInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing information
about selected rings. The entries
in the table may come from
several different data sources.
The number of entries is determined
by the number of sources that can
provide the information."
::= { s5TrRing 1 }
s5TrRingInfoEntry OBJECT-TYPE
SYNTAX S5TrRingInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in Token Ring information
table. Entries can not be created
or deleted via SNMP."
INDEX { s5TrRingInfoSrcIndx }
::= { s5TrRingInfoTable 1 }
S5TrRingInfoEntry ::= SEQUENCE {
s5TrRingInfoSrcIndx SrcIndx,
s5TrRingInfoRingNum INTEGER,
s5TrRingInfoStaTableOperSize INTEGER,
s5TrRingInfoActiveStations INTEGER,
s5TrRingInfoDeletes Counter,
s5TrRingInfoLastDeleteTime TimeTicks,
s5TrRingInfoAgeInterval TimeIntervalSec,
s5TrRingInfoMonTime TimeTicks,
s5TrRingInfoRingState INTEGER,
s5TrRingInfoBeaconSender MacAddress,
s5TrRingInfoBeaconNaun MacAddress,
s5TrRingInfoBeaconType INTEGER,
s5TrRingInfoLastBeaconTime TimeTicks,
s5TrRingInfoActiveMonitor MacAddress,
s5TrRingInfoChanges Counter,
s5TrRingInfoRingPurgeEvents Counter,
s5TrRingInfoBeaconEvents Counter,
s5TrRingInfoBeaconTime TimeIntervalHrd,
s5TrRingInfoMonitorContentionEvents Counter,
s5TrRingInfoNaunChanges Counter,
s5TrRingInfoRingPollEvents Counter
}
s5TrRingInfoSrcIndx OBJECT-TYPE
SYNTAX SrcIndx
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the entry in the table.
This index identifies the source of the
information. Only those sources that provide
these statistics are in this table."
::= { s5TrRingInfoEntry 1 }
s5TrRingInfoRingNum OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ring number of the ring that is being
monitored. Each ring in a multiple ring network
is assigned a unique number. Together, a ring and
bridge number form a route designator. The ring
number is obtained by an NMM during the
initialization process.
Section 3.8.1 of IEEE 802.5 specification. "
::= { s5TrRingInfoEntry 2 }
s5TrRingInfoStaTableOperSize OBJECT-TYPE
SYNTAX INTEGER (1..300)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The operational size of the station info
table (i.e., table s5TrStaInfoTable). This
size is the maximum number of stations for
which information can be collected. (Note:
a ring is limited to a maximum 256 active
stations.) The station table may also contain
entries for inactive stations. The station
table may have any combination of active
and inactive stations (except the number of
active is limited to 256) up to the current
value of this object. For example if the value
of this object is 112, the station table could
contain 100 inactive and 12 active stations."
::= { s5TrRingInfoEntry 3 }
s5TrRingInfoActiveStations OBJECT-TYPE
SYNTAX INTEGER (1..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active stations on the
ring that is being monitored. This is the
number of active stations in the station
info table (i.e., table s5TrStaInfoTable)."
::= { s5TrRingInfoEntry 4 }
s5TrRingInfoDeletes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times stations were removed
from table s5TrStaInfoTable due to either
aging out or table overflow."
::= { s5TrRingInfoEntry 5 }
s5TrRingInfoLastDeleteTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when the last
station was removed from table
s5TrStaInfoTable. If this has not
occurred, then the value is zero."
::= { s5TrRingInfoEntry 6 }
s5TrRingInfoAgeInterval OBJECT-TYPE
SYNTAX TimeIntervalSec
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time used to age stations
from table s5TrStaInfoTable. If a station
has had a status of inactive in the last
time interval, it may be removed from
table s5TrStaInfoTable. A value of zero
means no aging is to occur."
DEFVAL { 0 }
::= { s5TrRingInfoEntry 7 }
s5TrRingInfoMonTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The length of time that the ring has been
monitored by the current source."
::= { s5TrRingInfoEntry 8 }
s5TrRingInfoRingState OBJECT-TYPE
SYNTAX INTEGER {
normalOperation(1),
ringPurge(2),
monitorContention(3),
beaconFrameStreaming(4),
beaconBitStreaming(5),
beaconRingSignalLoss(6),
beaconSetRecoveryMode(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current status of this ring.
The states are:
normalOperation(1).........ring operating without
any interruption.
ringPurge(2)...............Active monitor enters
the ring purge state whenever a token error
is detected.
monitorContention(3).......ring enters in monitor
contention state whenever the ring stations
need to establish an active monitor.
beaconFrameStreaming(4)....station which participates
in monitor contention and has monitor
contention timeout expired, receives multiple
claim tokens and cannot solve the contention
within one second.
beaconBitStreaming(5)......station which participates
in monitor contention, has 'monitor timeout'
and does not receive any claim token.
beaconRingSignalLoss(6)....station which has
'contention timeout' and participates in monitor
contention and detects the loss of incoming
signal.
beaconSetRecoveryMode(7)...station before acting as a
recovery station sends out beacon frame with a
recovery mode bit set."
::= { s5TrRingInfoEntry 9 }
s5TrRingInfoBeaconSender OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the sender of the
last beacon frame detected on the ring.
If no beacon frame has been detected,
then the value is equal to six octets
of zero."
::= { s5TrRingInfoEntry 10 }
s5TrRingInfoBeaconNaun OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the NAUN (next active
upstream neighbor) in the last beacon frame
detected on the ring. If no beacon frame has
been detected, then the value is equal to six
octets of zero."
::= { s5TrRingInfoEntry 11 }
s5TrRingInfoBeaconType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
recovery(2),
signalLoss(3),
bitStreaming(4),
contentionStreaming(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the last beacon frame detected
on the ring. The values are:
other(1).................No beacon seen or
some other type
recovery(2)..............station before acting
as a recovery station sends out a beacon
frame with a recovery mode bit set.
signalLoss(3)............station which has
'contention timeout' and participates in
monitor contention and detects the loss
of incoming signal.
bitStreaming(4)..........station which participates
in monitor contention, has monitor timeout
and does not receive any claim token.
contentionStreaming(5)...station which participates
in monitor contention and has monitor
contention timeout expired, receives multiple
claim tokens and cannot solve the contention
within one second."
::= { s5TrRingInfoEntry 12 }
s5TrRingInfoLastBeaconTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when the last beacon
frame was detected on the ring. If one has not
been detected, then the value is zero."
::= { s5TrRingInfoEntry 13 }
s5TrRingInfoActiveMonitor OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the Active Monitor
on the ring. If this address is unknown,
then the value is equal to six octets
of zero."
::= { s5TrRingInfoEntry 14 }
s5TrRingInfoChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of add and delete events in the
station info table associated with
this ring. If no changes have occurred,
then the value is zero."
::= { s5TrRingInfoEntry 15 }
s5TrRingInfoRingPurgeEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of times that the ring has
entered the ring purge state from the normal ring
state. The ring purge state that comes from the
monitor contention or beacon state is not counted."
::= { s5TrRingInfoEntry 16 }
s5TrRingInfoBeaconEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of times that the ring has
entered the beaconing state."
::= { s5TrRingInfoEntry 17 }
s5TrRingInfoBeaconTime OBJECT-TYPE
SYNTAX TimeIntervalHrd
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total amount of time that the ring has been
in the beaconing state. This beacon time is
updated anytime whenever the ring enters a
beaconing state."
::= { s5TrRingInfoEntry 18 }
s5TrRingInfoMonitorContentionEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of times that the ring has
entered the monitor contention state from the
normal ring state or ring purge state. The
monitor contention state that comes from the
beacon state is not counted."
::= { s5TrRingInfoEntry 19 }
s5TrRingInfoNaunChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of NAUN (Nearest Active
Upstream Neighbor) changes that have been
measured. This is determined by the number
of Report SUA change MAC frames that have
been detected."
::= { s5TrRingInfoEntry 20 }
s5TrRingInfoRingPollEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of ring poll events that have
been detected."
::= { s5TrRingInfoEntry 21 }
-- Station Info Table
s5TrStaInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5TrStaInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing information about
the stations on selected rings. The
number of rings is determined by the
number of data sources. The number of
stations is determined by the number
on each ring limited by the configured
maximum number. An entry will exist
for each station that is now or has
previously been detected on the ring.
This table extends each row in the
s5TrRingInfoTable with station
information."
::= { s5TrRing 2 }
s5TrStaInfoEntry OBJECT-TYPE
SYNTAX S5TrStaInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the station info table.
Entries can not be created or
deleted via SNMP."
INDEX { s5TrStaInfoSrcIndx,
s5TrStaInfoAddr }
::= { s5TrStaInfoTable 1 }
S5TrStaInfoEntry ::= SEQUENCE {
s5TrStaInfoSrcIndx SrcIndx,
s5TrStaInfoAddr MacAddress,
s5TrStaInfoLastNaun MacAddress,
s5TrStaInfoStationStatus INTEGER,
s5TrStaInfoFirstEnterTime TimeTicks,
s5TrStaInfoLastEnterTime TimeTicks,
s5TrStaInfoLastExitTime TimeTicks,
s5TrStaInfoDupAddrErrs Counter,
s5TrStaInfoInLineErrs Counter,
s5TrStaInfoOutLineErrs Counter,
s5TrStaInfoInternalErrs Counter,
s5TrStaInfoInBurstErrs Counter,
s5TrStaInfoOutBurstErrs Counter,
s5TrStaInfoInACErrs Counter,
s5TrStaInfoOutACErrs Counter,
s5TrStaInfoAbortErrs Counter,
s5TrStaInfoLostFrameErrs Counter,
s5TrStaInfoCongestionErrs Counter,
s5TrStaInfoFrameCopiedErrs Counter,
s5TrStaInfoFrequencyErrs Counter,
s5TrStaInfoTokenErrs Counter,
s5TrStaInfoInBeaconErrs Counter,
s5TrStaInfoOutBeaconErrs Counter,
s5TrStaInfoInsertions Counter
}
s5TrStaInfoSrcIndx OBJECT-TYPE
SYNTAX SrcIndx
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the associated entry in
table s5TrRingInfoTable.
This index identifies the source of the
information. Only those sources that provide
these statistics are in this table."
::= { s5TrStaInfoEntry 1 }
s5TrStaInfoAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the station."
::= { s5TrStaInfoEntry 2 }
s5TrStaInfoLastNaun OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the last known NAUN (Next
Active Upstream Neighbor) of this station."
::= { s5TrStaInfoEntry 3 }
s5TrStaInfoStationStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
notInRingPoll(2),
inactive(3),
forcedRemoval(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The insertion status of the station
on the ring. The values are:
active(1)..........Actively participating in
ring poll
notInRingPoll(2)...Detected on the ring, but
not currently participating
in the ring poll
inactive(3)........No longer on the ring
forcedRemoval(4)...Forced off the ring by
network management"
::= { s5TrStaInfoEntry 4 }
s5TrStaInfoFirstEnterTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time the station
first entered the ring. If the time is unknown,
the value shall be zero."
::= { s5TrStaInfoEntry 5 }
s5TrStaInfoLastEnterTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time the station
last entered the ring. If the time is unknown,
the value shall be zero."
::= { s5TrStaInfoEntry 6 }
s5TrStaInfoLastExitTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time the station
last exited the ring. If the time is unknown,
the value shall be zero."
::= { s5TrStaInfoEntry 7 }
s5TrStaInfoDupAddrErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the station experienced
a duplicate address error. This error is reported
by a station via a Report Monitor Error MAC frame.
Section 3.8.8 of IEEE 802.5 specificatiuon."
::= { s5TrStaInfoEntry 8 }
s5TrStaInfoInLineErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of line errors reported by
by the station in error report frames
and detected on the ring.
Section 3.8.1 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 9 }
s5TrStaInfoOutLineErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of line errors reported by
by the nearest active downstream neighbor
of the station in error report frames
and detected on the ring.
Section 3.8.1 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 10 }
s5TrStaInfoInternalErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of adapter internal errors
reported by the station in error report
frames and detected on the ring.
Section 3.8.2 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 11 }
s5TrStaInfoInBurstErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of burst errors reported by
the station in error report frames
and detected on the ring.
Section 3.8.3 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 12 }
s5TrStaInfoOutBurstErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of burst errors reported by
the nearest active downstream neighbor of
the station in error report frames and
detected on the ring.
Section 3.8.3 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 13 }
s5TrStaInfoInACErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of AC (Address Copied) errors
reported by the station in error report frames
and detected on the ring.
Section 3.8.4 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 14 }
s5TrStaInfoOutACErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of AC (Address Copied) errors
reported by the nearest active downstream
neighbor of the station in error report frames
and detected on the ring.
Section 3.8.4 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 15 }
s5TrStaInfoAbortErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of abort delimiter transmitted
errors reported by the station in error report
frames and detected on the ring.
Section 3.8.5 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 16 }
s5TrStaInfoLostFrameErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of frames lost errors reported
by the station in error report frames and
detected on the ring.
Section 3.8.6 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 17 }
s5TrStaInfoCongestionErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of receive congestion errors
reported by the station in error report
frames and detected on the ring.
Section 3.8.7 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 18 }
s5TrStaInfoFrameCopiedErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of frame copied errors reported
by the station in error report frames and
detected on the ring.
Section 3.8.8 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 19 }
s5TrStaInfoFrequencyErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of frequency errors reported
by the station in error report frames
and detected on the ring.
Section 3.8.9 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 20 }
s5TrStaInfoTokenErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of token errors reported by
the station in error report frames and
detected on the ring.
Section 3.8.10 of IEEE 802.5 specification."
::= { s5TrStaInfoEntry 21 }
s5TrStaInfoInBeaconErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of beacon frames sent by the
station and detected on the ring."
::= { s5TrStaInfoEntry 22 }
s5TrStaInfoOutBeaconErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of beacon frames detected on the
ring that name the station as the NAUN."
::= { s5TrStaInfoEntry 23 }
s5TrStaInfoInsertions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times that the station
was detected inserting onto the ring."
::= { s5TrStaInfoEntry 24 }
-- Station Control Table
s5TrStaCtlTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5TrStaCtlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing control objects
and addition information about the
stations on selected rings. The
number of rings is determined by the
number of data sources.
This table extends each row in table
s5TrStaInfoTable with additional information
and control objects."
::= { s5TrRing 3 }
s5TrStaCtlEntry OBJECT-TYPE
SYNTAX S5TrStaCtlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the station control table.
Entries can not be created or
deleted via SNMP."
INDEX { s5TrStaCtlSrcIndx,
s5TrStaCtlAddr }
::= { s5TrStaCtlTable 1 }
S5TrStaCtlEntry ::= SEQUENCE {
s5TrStaCtlSrcIndx SrcIndx,
s5TrStaCtlAddr MacAddress,
s5TrStaCtlRemove INTEGER,
s5TrStaCtlUpdateStats INTEGER,
s5TrStaCtlUpdateTime TimeTicks,
s5TrStaCtlProductId OCTET STRING,
s5TrStaCtlNodeVersion OCTET STRING,
s5TrStaCtlPhysDrop OCTET STRING,
s5TrStaCtlFuncAddr MacAddress,
s5TrStaCtlAuthFuncClass OCTET STRING,
s5TrStaCtlAuthAccPriority OCTET STRING,
s5TrStaCtlStationId MacAddress,
s5TrStaCtlNumGrpAddr MacAddress
}
s5TrStaCtlSrcIndx OBJECT-TYPE
SYNTAX SrcIndx
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The first index of the associated entry
in table s5TrStaInfoTable.
This index identifies the source of the
information. Only those sources that provide
these statistics are in this table."
::= { s5TrStaCtlEntry 1 }
s5TrStaCtlAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The second index of the associated entry
in table s5TrStaInfoTable. This index is
the MAC address of the station."
::= { s5TrStaCtlEntry 2 }
s5TrStaCtlRemove OBJECT-TYPE
SYNTAX INTEGER {
stable(1),
remove(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is an action object to send a Remove
Station MAC frame to the station. The following
value can be written:
remove(2)...causes a frame to be sent
The following values can be read:
stable(1)...a frame is not currently
being sent
remove(2)...in progress of sending a frame."
::= { s5TrStaCtlEntry 3 }
s5TrStaCtlUpdateStats OBJECT-TYPE
SYNTAX INTEGER {
other(1),
inactive(2),
stable(3),
update(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is an action object used to cause
configuration information for the station
to be updated. The following value can
be written:
update(4)...causes update to be attempted
The following values can be read:
other(1)......configuration information not
currently valid
inactive(2)...the station is currently inactive
stable(3).....configuration information is
currently valid
update(4).....updating configuration info
The object s5TrStaCtlUpdateTime has the
time that the configuration was last updated.
If a station is currently not on the ring,
the value inactive(2) will be returned.
A SET with value update(4) to an inactive station
will result in a value of inactive(2)."
::= { s5TrStaCtlEntry 4 }
s5TrStaCtlUpdateTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time the
configuration information was last updated
(completely). If the information has never
been gotten, then the value is zero. The
config info is updated whenever a station
is first detected on the ring."
::= { s5TrStaCtlEntry 5 }
s5TrStaCtlProductId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..18))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A brief string describing the product specified
by the vendor. The value is a zero length string
when not valid (or available).
Section 3.3.2.14 of IEEE 802.5 specification.
NOTE: The characters in the string are represented
in EBCDIC for IBM products, in ASCII for others."
::= { s5TrStaCtlEntry 6 }
s5TrStaCtlNodeVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A string that represents the version of the
station software. The value is a zero length
string when not valid (or available).
Section 3.3.2.17 of IEEE 802.5 specification.
NOTE: The characters in the string are represented
in EBCDIC for IBM products, in ASCII for others.
The octet string is represented in the following
format for IBM products:
octets from 0 to 4 : Feature Code
octets from 5 to 9 : EC level."
::= { s5TrStaCtlEntry 7 }
s5TrStaCtlPhysDrop OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The physical location of the station on the
ring. The value is 4 octets of zero when not
valid (or available).
Section 3.3.2.13 of IEEE 802.5 specification."
::= { s5TrStaCtlEntry 8 }
s5TrStaCtlFuncAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The functional addresses used by the station.
The value is 6 octets of zero when not valid
(or available).
Section 3.3.2.8 of IEEE 802.5 specification."
::= { s5TrStaCtlEntry 9 }
s5TrStaCtlAuthFuncClass OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The functional classes that are allowed to
be active in the station. The value is 2
octets of zero when not valid (or available).
Section 3.3.2.3 of IEEE 802.5 specification."
::= { s5TrStaCtlEntry 10 }
s5TrStaCtlAuthAccPriority OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum priority this station is allowed
to use. The value is 2 octets of zero when
not valid (or available).
Section 3.3.2.2 of IEEE 802.5 specification."
::= { s5TrStaCtlEntry 11 }
s5TrStaCtlStationId OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This string is used to uniquely identify
the station. It may be equal to the station's
MAC address. The value is 6 octets of zero
when not valid (or available).
Section 3.3.2.21 of IEEE 802.5 specification."
::= { s5TrStaCtlEntry 12 }
s5TrStaCtlNumGrpAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The group address for the station.
The value is zero if not valid or
no group address has been assigned.
Section 3.3.2.9 of IEEE 802.5 specification."
::= { s5TrStaCtlEntry 13 }
-- Test Path Group
s5TrTestPathTestTimer OBJECT-TYPE
SYNTAX TimeIntervalHrd
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the timeout, in units of hundredths of a second,
that the agent will wait for a reply to an LLC TEST
command PDU caused by doing a SNMP SET to the object
s5TrAgentTpStart with the value startTestSourceRoute(2)
or startTestTransparent(3). This timer applies to all
entries in table s5TrTestPathTable."
DEFVAL { 400 } -- 4 seconds
::={s5TrTest 1}
s5TrTestPathAgeTimer OBJECT-TYPE
SYNTAX TimeIntervalSec (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time, in units of seconds, that
an entry remains in table s5TrTestPathTable before
it is automatically removed. This value must be larger
than the value of s5TrTestPathTimer. This timer
applies to all entries in table s5TrTestPathTable.
When the value is 0, no entry will be aged out."
DEFVAL { 300 } -- 5 minutes
::={s5TrTest 2}
s5TrTestPathTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5TrTestPathEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table is used to initiate a 'path test' between
the agent and a station in the flatnet. To start a
path test, a SNMP SET operation is attempted with the
value of the object s5TrTestTpStart set to
startTestSourceRoute(2) or startTestTransparent(3).
There can only be one test active between the
agent and a particular station at any time.
The table size has an implementation limit. It is
determined by the agent.
Note: Performing a path test on a destination station
which does not recognize or reply to 802.2 TEST
command PDU will result in a 'test-failed'."
::={s5TrTest 3}
s5TrTestPathEntry OBJECT-TYPE
SYNTAX S5TrTestPathEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the test path table. Entries can be created
with a SNMP SET request by setting the object
s5TrTestTpStart to either startTestSourceRoute(2) or
startTestTransparent(3) or by setting the object
s5TrTestTpRoute to some specific route string, with the
index portion of the object specifying the source
(s5TrTestTpIfIndex) and destination MAC address
(s5TrTestTpAddrTo).
If s5TrTestTpRoute is set to some specific route string
and s5TrTestTpStart is not startTestSourceRoute(2),
startTestTransparent(3), retryTestSourceRoute(4),
retryTestTransparent(5), or clearTest(6), the agent will
set s5TrTestTpStart to startTestSourceRoute(2).
After the entry is created, it will live in the table until it
is aged out by the value of s5TrTestPathAgeTimer or
until it is removed by setting s5TrTestTpStart to
clearTest(6)."
INDEX { s5TrTestTpIfIndex, s5TrTestTpAddrTo }
::={s5TrTestPathTable 1}
S5TrTestPathEntry ::= SEQUENCE {
s5TrTestTpIfIndex INTEGER,
s5TrTestTpAddrTo OCTET STRING,
s5TrTestTpStart INTEGER,
s5TrTestTpStatus INTEGER,
s5TrTestTpRoute OCTET STRING,
s5TrTestTpDuration TimeIntervalHrd,
s5TrTestTpTimeStamp TimeTicks
}
s5TrTestTpIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index from the ifTable of a token ring interface.
This is the source of the TEST command PDU."
::={s5TrTestPathEntry 1}
s5TrTestTpAddrTo OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The destination MAC address to be used for the
testpath operation."
::={s5TrTestPathEntry 2}
s5TrTestTpStart OBJECT-TYPE
SYNTAX INTEGER {
other(1),
startTestSourceRoute(2),
startTestTransparent(3),
retryTestSourceRoute(4),
retryTestTransparent(5),
clearTest(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to start or retry a test or delete an
entry. The possible values that can be written
are:
startTestSourceRoute(2)...Start a path test for
networks using source
routing bridging.
startTestTransparent(3)...Start a path test for
networks using
transparent bridging.
retryTestSourceRoute(4)...Retry the path test for
networks using source
routing bridging.
retryTestTransparent(5)...Retry the path test for
networks using
transparent bridging.
clearTest(6)..........Delete an entry.
The possible values that can be read are:
other(1) none of the following.
startTestSourceRoute(2)...Indicates a path test for
networks using source
routing bridging has
been started.
startTestTransparent(3)...Indicates a path test for
networks using
transparent bridging has
been started.
retryTestSourceRoute(4)...Indicates the path test for
networks using source
routing bridging has
been retried.
retryTestTransparent(5)...Indicates the path test for
networks using
transparent bridging has
been retried.
If s5TrTestTpStart is set to startTestTransparent(3) or
retryTestTransparent(5), the value of s5TrTestTpRoute is
ignored. A TEST command PDU without source routing
information will be sent by the agent.
If s5TrTestTpStart is set to startTestSourceRoute(2) or
retryTestSourceRoute(5) and the value
s5TrTestTpRoute is a zero length string, a single-route
broadcast TEST command PDU will be sent to explore the
route from the agent to s5TrTestTpAddrTo. If
s5TrTestTpRoute contains some specific route, the agent
will send a nonbroadcast TEST command PDU to check
this route.
If a test between the station identified by the
object s5TrTestTpStart and the agent has already been
started (so the s5TrTestTpStatus has value
testInProgress(2)), the agent will return 'no
error' to the SNMP SET request of a start or retry value.
However, the agent will not initiate a new TEST
command PDU.
If the test cannot be started because of errors
in the SET request, or because of some limitations
on the agent side (e.g., the table limit has been
exceeded), then the response to the SET request will
be SNMP 'bad value' or 'general' error.
For both start-test and retry-test the age-out time for
the entry will be refreshed (i.e., as if the entry was just
created)."
DEFVAL { startTestSourceRoute }
::={s5TrTestPathEntry 3}
s5TrTestTpStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
testInProgress(2),
testPassed(3),
testFailed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current status of the test. The possible values
are :
testInProgress(2)...The path test is currently in progress.
testPassed(3).......The path test passed.
testFailed(4).......The path test failed.
If the interval of time between the agent's request
and the station's response is less than s5TrTestPathTimer,
then the value will be testPassed(3). If the interval is
longer, the value will be testFailed(4). While the
agent is waiting for a response, the value will be
testInProgress(2)."
::={s5TrTestPathEntry 4}
s5TrTestTpRoute OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this object is written via SNMP it specifies
the path to be tested. If this object is not written
when the row is created, it is filled in by the agent
when the path test is completed.
This object is an encoded octet string that specifies
the source route path. The first octet represents the
length in octets of the route string that follows.
Each two octets that follow specify a ring number/bridge
number pair representing an entry for a hop. The
encoding is 3 nibbles for the ring number, and 1 nibble
for bridge number. The maximum size of this path
represents 7 hops (14 Octets).
To initiate a test, write to this object with the
appropriate route. If the corresponding table entry
s5TrTestTpStart is not set, the agent will set
s5TrTestTpStart to startTestSourceRoute(2) and start
the test.
If the agent and the station are both on the same
ring, the length octet will be set to zero by agent.
If a 'Transparent path test' succeeds and the route passes
through transparent bridges, then length octet will be
set to 1 by agent. This is to differentiate from the case
that the station and the agent are on the same ring."
DEFVAL { "" } -- Zero length string
::={s5TrTestPathEntry 5}
s5TrTestTpDuration OBJECT-TYPE
SYNTAX TimeIntervalHrd
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This specifies the round trip time of a successful
test in units of hundreds of a second. This object will be
equal to the value of s5TrTestPathTimer if the
test has failed"
::={s5TrTestPathEntry 6}
s5TrTestTpTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the time stamp (i.e., sysUpTime) of the last
time that the path test was run successfully."
::={s5TrTestPathEntry 7}
END