mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-24 02:54:19 +00:00
1608 lines
50 KiB
Plaintext
Executable File
1608 lines
50 KiB
Plaintext
Executable File
-- ****************************************************************************
|
|
-- LEFTHAND-NETWORKS-NSM-NOTIFICATION-MIB
|
|
-- Management Information Base for SNMP Network Management
|
|
--
|
|
-- This MIB provides notification (trap) information for a storage node.
|
|
|
|
-- This MIB must be loaded after:
|
|
-- LEFTHAND-NETWORKS-GLOBAL-REG-MIB.mib
|
|
-- LEFTHAND-NETWORKS-NSM-MIB.mib
|
|
--
|
|
-- The LeftHand Networks Enterprise number is 9804.
|
|
-- The ASN.1 prefix to, and including the LeftHand Networks Enterprise is:
|
|
-- 1.3.6.1.4.1.9804
|
|
-- ****************************************************************************
|
|
-- Copyright 2009,2010 Hewlett-Packard Development Company, L.P.
|
|
-- Copyright 2008,2009 LeftHand Networks, Inc.
|
|
-- All Rights Reserved.
|
|
--
|
|
-- Hewlett-Packard Company shall not be liable for technical or
|
|
-- editorial errors or omissions contained herein. The information in
|
|
-- this document is provided "as is" without warranty of any kind and
|
|
-- is subject to change without notice. The warranties for HP products
|
|
-- are set forth in the express limited warranty statements
|
|
-- accompanying such products. Nothing herein should be construed as
|
|
-- constituting an additional warranty.
|
|
--
|
|
-- Confidential computer software. Valid license from HP required for
|
|
-- possession, use or copying. Consistent with FAR 12.211 and 12.212,
|
|
-- Commercial Computer Software, Computer Software Documentation, and
|
|
-- Technical Data for Commercial Items are licensed to the U.S.
|
|
-- Government under vendor's standard commercial license.
|
|
-- ****************************************************************************
|
|
|
|
LEFTHAND-NETWORKS-NSM-NOTIFICATION-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32, Gauge32
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION, DisplayString, DateAndTime, TruthValue
|
|
FROM SNMPv2-TC
|
|
lhnModules, lhnNsm
|
|
FROM LEFTHAND-NETWORKS-GLOBAL-REG-MIB
|
|
lhnNsmNotification, lhnNsmEvents, lhnNsmOldNotification, lhnNsmOldEvents
|
|
FROM LEFTHAND-NETWORKS-NSM-MIB;
|
|
|
|
-- lhnNsm is imported but never used, this will create a smilint warning
|
|
-- however, it's necessary for some MIB compilers
|
|
|
|
--
|
|
-- Module definition and a brief description of this mib.
|
|
--
|
|
lhnNsmNotificationModule MODULE-IDENTITY
|
|
LAST-UPDATED "201007160000Z"
|
|
ORGANIZATION "Hewlett Packard Company, StorageWorks Division"
|
|
CONTACT-INFO "Product Support
|
|
Product URL: www.hp.com/go/p4000
|
|
Support URL: www.itrc.hp.com
|
|
Product Phone: www.hp.com/go/contact
|
|
1-800-786-7967 (US only)
|
|
Support Phone: www.hp.com/go/contact
|
|
1-800-334-5144 (US only)"
|
|
DESCRIPTION "HP StorageWorks P4000 Notifications:
|
|
Traps(v1) and Informs(v2c)"
|
|
REVISION "201007160000Z"
|
|
DESCRIPTION "SAN/iQ 7.0, SAN/iQ 8.0, SAN/iQ 8.1, SAN/iQ 8.5"
|
|
|
|
::= { lhnModules 15 }
|
|
|
|
-- lhnNsmDevices and lhnNsmEvents are redefined(duplicated) in this MIB to
|
|
-- increase compatability with some SNMP clients
|
|
|
|
lhnNsmDevices OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "sub-tree for NSM devices"
|
|
::= { lhnNsm 1 }
|
|
|
|
lhnNsmEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "sub-tree for NSM events"
|
|
::= { lhnNsmDevices 0 }
|
|
|
|
--******************************************************************************
|
|
--
|
|
-- Conformance
|
|
--
|
|
--******************************************************************************
|
|
|
|
lhnNsmNotificationModuleConformance OBJECT IDENTIFIER
|
|
::= { lhnNsmNotificationModule 1 }
|
|
|
|
lhnNsmNotificationModuleCompliances OBJECT IDENTIFIER
|
|
::= { lhnNsmNotificationModuleConformance 1 }
|
|
|
|
lhnNsmNotificationModuleGroups OBJECT IDENTIFIER
|
|
::= { lhnNsmNotificationModuleConformance 2 }
|
|
|
|
lefthandNetworksNsmNotificationMibCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION "The compliance statement."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
lefthandNetworksNsmNotificationGroup,
|
|
lefthandNetworksNsmNotificationMibAllNotifications
|
|
}
|
|
::= { lhnNsmNotificationModuleCompliances 1 }
|
|
|
|
lefthandNetworksNsmNotificationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
notificationOldMessageCount,
|
|
notificationMessage,
|
|
notificationTime,
|
|
notificationMessageCount,
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
systemName,
|
|
logicalName,
|
|
componentState,
|
|
componentModel,
|
|
componentSerialNumber,
|
|
componentFirmwareVersion,
|
|
componentHardwareVersion,
|
|
driverVersion,
|
|
biosVersion,
|
|
raidConfiguration,
|
|
diskInterface,
|
|
diskCapacity,
|
|
raidState,
|
|
parityInitStatus,
|
|
healthState,
|
|
bbuState,
|
|
cacheState,
|
|
linkState,
|
|
vipState,
|
|
maintenanceMode,
|
|
minFanSpeed,
|
|
fanSpeed,
|
|
highTemperatureLimit,
|
|
temperatureState,
|
|
temperature,
|
|
highVoltageLimit,
|
|
lowVoltageLimit,
|
|
voltage,
|
|
utilization,
|
|
latency,
|
|
memoryUtilization,
|
|
memoryConfig,
|
|
cpuUtilization,
|
|
cpuConfig,
|
|
diskSpeed,
|
|
licenseState,
|
|
utilizationState,
|
|
latencyState,
|
|
serverVIPAddress,
|
|
serverVIPState,
|
|
replicationState,
|
|
snapshotState,
|
|
snapshotSchedState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The default group for all NSM Notification objects."
|
|
::= { lhnNsmNotificationModuleGroups 1 }
|
|
|
|
lefthandNetworksNsmNotificationMibAllNotifications NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
userNotification,
|
|
lhnNsmNotificationGeneric,
|
|
lhnNsmNotificationBackplane,
|
|
lhnNsmNotificationController,
|
|
lhnNsmNotificationRAID,
|
|
lhnNsmNotificationDisk,
|
|
lhnNsmNotificationBootDevice,
|
|
lhnNsmNotificationFan,
|
|
lhnNsmNotificationTemperature,
|
|
lhnNsmNotificationPowerSupply,
|
|
lhnNsmNotificationVoltage,
|
|
lhnNsmNotificationNetwork,
|
|
lhnNsmNotificationMemory,
|
|
lhnNsmNotificationCPU,
|
|
lhnNsmNotificationLogging,
|
|
lhnNsmNotificationManagementGroup,
|
|
lhnNsmNotificationRemoteManagementGroup,
|
|
lhnNsmNotificationCluster,
|
|
lhnNsmNotificationStorageServer,
|
|
lhnNsmNotificationRemoteCopy,
|
|
lhnNsmNotificationVolume,
|
|
lhnNsmNotificationSnapshot
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The default group for all NSM Notification objects."
|
|
::= { lhnNsmNotificationModuleGroups 2 }
|
|
|
|
--******************************************************************************
|
|
--
|
|
-- Notification Objects
|
|
--
|
|
--******************************************************************************
|
|
|
|
--******************************************************************************
|
|
-- In SAN/iQ 8.1 and earlier all notifications were SNMP v2c notifications
|
|
-- from a single OID:
|
|
-- LEFTHAND-NETWORKS-NSM-NOTIFICATION-MIB::userNotification
|
|
-- .1.3.6.1.4.1.9804.3.1.1.3.1
|
|
--
|
|
-- In SAN/iQ 8.5 and later notifications can be sent as SNMP v1 traps or
|
|
-- SNMP v2 notifications and use multiple OIDs defined in this MIB.
|
|
--******************************************************************************
|
|
|
|
notificationMessageCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of notification messages available in the history."
|
|
::= { lhnNsmNotification 1 }
|
|
|
|
notificationMessageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NotificationMessageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of the last 100 notifications for the NSM.
|
|
The number of entries is given by messageNotificationCount."
|
|
::= { lhnNsmNotification 2 }
|
|
|
|
notificationMessageEntry OBJECT-TYPE
|
|
SYNTAX NotificationMessageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A row of notification message information.
|
|
The information contained in each row is dependant on the trap type
|
|
and the event that caused the trap. Not all NotificationMessageEntry
|
|
objects will have values."
|
|
INDEX {
|
|
notificationMessageIndex
|
|
}
|
|
::= { notificationMessageTable 1 }
|
|
|
|
NotificationMessageEntry ::= SEQUENCE {
|
|
notificationMessageIndex Unsigned32,
|
|
message DisplayString,
|
|
messageTime DateAndTime,
|
|
eventID DisplayString,
|
|
severity INTEGER,
|
|
hostname DisplayString,
|
|
primaryIP DisplayString,
|
|
mac DisplayString,
|
|
serialNumber DisplayString,
|
|
modelName DisplayString,
|
|
productName DisplayString,
|
|
productID DisplayString,
|
|
hpim TruthValue,
|
|
softwareVersion DisplayString,
|
|
managementGroupVersion DisplayString,
|
|
managementGroupSerialNumber DisplayString,
|
|
managementGroup DisplayString,
|
|
cluster DisplayString,
|
|
site DisplayString,
|
|
componentName DisplayString,
|
|
systemName DisplayString,
|
|
logicalName DisplayString,
|
|
componentState DisplayString,
|
|
componentModel DisplayString,
|
|
componentSerialNumber DisplayString,
|
|
componentFirmwareVersion DisplayString,
|
|
componentHardwareVersion DisplayString,
|
|
driverVersion DisplayString,
|
|
biosVersion DisplayString,
|
|
raidConfiguration DisplayString,
|
|
diskInterface DisplayString,
|
|
diskCapacity Integer32,
|
|
raidState DisplayString,
|
|
parityInitStatus DisplayString,
|
|
healthState DisplayString,
|
|
bbuState DisplayString,
|
|
cacheState DisplayString,
|
|
linkState DisplayString,
|
|
vipState DisplayString,
|
|
maintenanceMode DisplayString,
|
|
minFanSpeed Integer32,
|
|
fanSpeed Gauge32,
|
|
highTemperatureLimit Integer32,
|
|
temperatureState DisplayString,
|
|
temperature Gauge32,
|
|
highVoltageLimit Integer32,
|
|
lowVoltageLimit Integer32,
|
|
voltage Gauge32,
|
|
utilization Gauge32,
|
|
latency Gauge32,
|
|
memoryUtilization Gauge32,
|
|
memoryConfig Integer32,
|
|
cpuUtilization Gauge32,
|
|
cpuConfig Integer32,
|
|
diskSpeed DisplayString,
|
|
licenseState DisplayString,
|
|
utilizationState DisplayString,
|
|
latencyState DisplayString,
|
|
serverVIPAddress DisplayString,
|
|
serverVIPState DisplayString,
|
|
replicationState DisplayString,
|
|
snapshotState DisplayString,
|
|
snapshotSchedState DisplayString
|
|
}
|
|
|
|
notificationMessageIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The index for the notificationMessageTable table."
|
|
::= { notificationMessageEntry 1 }
|
|
|
|
message OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The notification message."
|
|
::= { notificationMessageEntry 2 }
|
|
|
|
messageTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The time the notification was sent."
|
|
::= { notificationMessageEntry 3 }
|
|
|
|
eventID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The event ID in symbolic format."
|
|
::= { notificationMessageEntry 4 }
|
|
|
|
severity OBJECT-TYPE
|
|
SYNTAX INTEGER { critical(0), warning(1), info(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The event severity."
|
|
::= { notificationMessageEntry 5 }
|
|
|
|
hostname OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The NSM hostname."
|
|
::= { notificationMessageEntry 6 }
|
|
|
|
primaryIP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The primary IP address."
|
|
::= { notificationMessageEntry 7 }
|
|
|
|
mac OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The MAC address of the primary IP address."
|
|
::= { notificationMessageEntry 8 }
|
|
|
|
serialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The chassis serial number."
|
|
::= { notificationMessageEntry 9 }
|
|
|
|
modelName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The system model name."
|
|
::= { notificationMessageEntry 10 }
|
|
|
|
productName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The OEM product name."
|
|
::= { notificationMessageEntry 11 }
|
|
|
|
productID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The OEM product ID."
|
|
::= { notificationMessageEntry 12 }
|
|
|
|
hpim OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "HP Insight Manager SNMP agent installed on NSM"
|
|
::= { notificationMessageEntry 13 }
|
|
|
|
softwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The SAN/iQ software version"
|
|
::= { notificationMessageEntry 14 }
|
|
|
|
managementGroupVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The management group version."
|
|
::= { notificationMessageEntry 15 }
|
|
|
|
managementGroupSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The management group serial number."
|
|
::= { notificationMessageEntry 16 }
|
|
|
|
managementGroup OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The management group name."
|
|
::= { notificationMessageEntry 17 }
|
|
|
|
cluster OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The cluster name."
|
|
::= { notificationMessageEntry 18 }
|
|
|
|
site OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The site the cluster is in."
|
|
::= { notificationMessageEntry 19 }
|
|
|
|
componentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The component name."
|
|
::= { notificationMessageEntry 20 }
|
|
|
|
systemName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The system hostname."
|
|
::= { notificationMessageEntry 21 }
|
|
|
|
logicalName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The logical name for the component."
|
|
::= { notificationMessageEntry 22 }
|
|
|
|
componentState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The component state."
|
|
::= { notificationMessageEntry 23 }
|
|
|
|
componentModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The component model."
|
|
::= { notificationMessageEntry 24 }
|
|
|
|
componentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The component serial number."
|
|
::= { notificationMessageEntry 25 }
|
|
|
|
componentFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The component firmware version."
|
|
::= { notificationMessageEntry 26 }
|
|
|
|
componentHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The component hardware version."
|
|
::= { notificationMessageEntry 27 }
|
|
|
|
driverVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The driver version."
|
|
::= { notificationMessageEntry 28 }
|
|
|
|
biosVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The BIOS version."
|
|
::= { notificationMessageEntry 29 }
|
|
|
|
raidConfiguration OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RAID configuration."
|
|
::= { notificationMessageEntry 30 }
|
|
|
|
diskInterface OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The disk interface type."
|
|
::= { notificationMessageEntry 31 }
|
|
|
|
diskCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "MB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The disk capacity."
|
|
::= { notificationMessageEntry 32 }
|
|
|
|
raidState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RAID state."
|
|
::= { notificationMessageEntry 33 }
|
|
|
|
parityInitStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RAID Parity Initialization status."
|
|
::= { notificationMessageEntry 34 }
|
|
|
|
healthState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The disk health state."
|
|
::= { notificationMessageEntry 35 }
|
|
|
|
bbuState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The BBU state."
|
|
::= { notificationMessageEntry 36 }
|
|
|
|
cacheState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The cache state."
|
|
::= { notificationMessageEntry 37 }
|
|
|
|
linkState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The link state."
|
|
::= { notificationMessageEntry 38 }
|
|
|
|
vipState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The cluster VIP state."
|
|
::= { notificationMessageEntry 39 }
|
|
|
|
maintenanceMode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The management group maintenance mode."
|
|
::= { notificationMessageEntry 40 }
|
|
|
|
minFanSpeed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "RPM"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The minimal fan speed."
|
|
::= { notificationMessageEntry 41 }
|
|
|
|
fanSpeed OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "RPM"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The fan speed."
|
|
::= { notificationMessageEntry 42 }
|
|
|
|
highTemperatureLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The high temperature limit."
|
|
::= { notificationMessageEntry 43 }
|
|
|
|
temperatureState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The component temperature state."
|
|
::= { notificationMessageEntry 44 }
|
|
|
|
temperature OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The component temperature."
|
|
::= { notificationMessageEntry 45 }
|
|
|
|
highVoltageLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The high voltage limit."
|
|
::= { notificationMessageEntry 46 }
|
|
|
|
lowVoltageLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The low voltage limit."
|
|
::= { notificationMessageEntry 47 }
|
|
|
|
voltage OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The voltage."
|
|
::= { notificationMessageEntry 48 }
|
|
|
|
utilization OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The rescource utilization."
|
|
::= { notificationMessageEntry 49 }
|
|
|
|
latency OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "ms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The storage server latency."
|
|
::= { notificationMessageEntry 50 }
|
|
|
|
memoryUtilization OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The memory utilization."
|
|
::= { notificationMessageEntry 51 }
|
|
|
|
memoryConfig OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "MB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The system memory configuration."
|
|
::= { notificationMessageEntry 52 }
|
|
|
|
cpuUtilization OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The CPU utilization."
|
|
::= { notificationMessageEntry 53 }
|
|
|
|
cpuConfig OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "cores"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of CPU cores."
|
|
::= { notificationMessageEntry 54 }
|
|
|
|
diskSpeed OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The disk interface speed."
|
|
::= { notificationMessageEntry 55 }
|
|
|
|
licenseState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The feature license state."
|
|
::= { notificationMessageEntry 56 }
|
|
|
|
utilizationState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The utilization state."
|
|
::= { notificationMessageEntry 57 }
|
|
|
|
latencyState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The storage server latency state."
|
|
::= { notificationMessageEntry 58 }
|
|
|
|
serverVIPAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The VIP address."
|
|
::= { notificationMessageEntry 59 }
|
|
|
|
serverVIPState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The VIP state."
|
|
::= { notificationMessageEntry 60 }
|
|
|
|
replicationState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The volume/snapshot replication state."
|
|
::= { notificationMessageEntry 61 }
|
|
|
|
snapshotState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The snapshot state."
|
|
::= { notificationMessageEntry 62 }
|
|
|
|
snapshotSchedState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The snapshot schedule state."
|
|
::= { notificationMessageEntry 63 }
|
|
|
|
--******************************************************************************
|
|
--
|
|
-- Current Notifications
|
|
--
|
|
--******************************************************************************
|
|
|
|
lhnNsmNotificationGeneric NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A generic system event was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 1 }
|
|
|
|
lhnNsmNotificationBackplane NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
componentSerialNumber,
|
|
componentFirmwareVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the system backplane was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 2 }
|
|
|
|
lhnNsmNotificationController NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
componentModel,
|
|
componentSerialNumber,
|
|
componentHardwareVersion,
|
|
componentFirmwareVersion,
|
|
driverVersion,
|
|
biosVersion,
|
|
cacheState,
|
|
bbuState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the RAID controller was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 3 }
|
|
|
|
lhnNsmNotificationRAID NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentState,
|
|
raidConfiguration,
|
|
parityInitStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the system RAID was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 4 }
|
|
|
|
lhnNsmNotificationDisk NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
componentModel,
|
|
componentSerialNumber,
|
|
componentFirmwareVersion,
|
|
diskInterface,
|
|
diskCapacity,
|
|
healthState,
|
|
temperatureState,
|
|
temperature,
|
|
diskSpeed
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a disk was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 5 }
|
|
|
|
lhnNsmNotificationBootDevice NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a boot device was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 6 }
|
|
|
|
lhnNsmNotificationFan NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
minFanSpeed,
|
|
fanSpeed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a fan was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 7 }
|
|
|
|
lhnNsmNotificationTemperature NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
highTemperatureLimit,
|
|
temperature
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a temperature sensor was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 8 }
|
|
|
|
lhnNsmNotificationPowerSupply NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a power supply was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 9 }
|
|
|
|
lhnNsmNotificationVoltage NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
highVoltageLimit,
|
|
lowVoltageLimit,
|
|
voltage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a voltage sensor was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 10 }
|
|
|
|
lhnNsmNotificationNetwork NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
systemName,
|
|
logicalName,
|
|
linkState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the network was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 11 }
|
|
|
|
lhnNsmNotificationMemory NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
memoryConfig,
|
|
memoryUtilization
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the system memory was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 12 }
|
|
|
|
lhnNsmNotificationCPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
cpuConfig,
|
|
cpuUtilization
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the CPU was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 13 }
|
|
|
|
lhnNsmNotificationLogging NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
utilization
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the log partition was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 14 }
|
|
|
|
lhnNsmNotificationManagementGroup NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
maintenanceMode,
|
|
licenseState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the management group was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 15 }
|
|
|
|
lhnNsmNotificationRemoteManagementGroup NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a remote management group was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 16 }
|
|
|
|
lhnNsmNotificationCluster NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
utilization,
|
|
vipState,
|
|
utilizationState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the cluster was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 17 }
|
|
|
|
lhnNsmNotificationStorageServer NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
latency,
|
|
latencyState,
|
|
serverVIPAddress,
|
|
serverVIPState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for the storage server was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 18 }
|
|
|
|
lhnNsmNotificationRemoteCopy NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
replicationState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a remote copy operation was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 19 }
|
|
|
|
lhnNsmNotificationVolume NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a volume was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 20 }
|
|
|
|
lhnNsmNotificationSnapshot NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
message,
|
|
messageTime,
|
|
eventID,
|
|
severity,
|
|
hostname,
|
|
primaryIP,
|
|
mac,
|
|
serialNumber,
|
|
modelName,
|
|
productName,
|
|
productID,
|
|
hpim,
|
|
softwareVersion,
|
|
managementGroupVersion,
|
|
managementGroupSerialNumber,
|
|
managementGroup,
|
|
cluster,
|
|
site,
|
|
componentName,
|
|
componentState,
|
|
snapshotState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "An event for a snapshot was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Added in SAN/iQ 8.5"
|
|
::= { lhnNsmEvents 21 }
|
|
|
|
--******************************************************************************
|
|
--
|
|
-- Obsolete Notifications
|
|
--
|
|
--******************************************************************************
|
|
|
|
notificationOldMessageCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "number of notification messages
|
|
Used by SAN/iQ 8.1 and earlier.
|
|
Obsolete in SAN/iQ 8.5.
|
|
Marked as current to increase compatability with some SNMP clients."
|
|
::= { lhnNsmOldNotification 1 }
|
|
|
|
notificationOldMessageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NotificationOldMessageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table of notification messages for the NSM.
|
|
The number of entries is given by notificationMessageCount.
|
|
Used by SAN/iQ 8.1 and earlier.
|
|
Obsolete in SAN/iQ 8.5.
|
|
Marked as current to increase compatability with some SNMP clients."
|
|
::= { lhnNsmOldNotification 2 }
|
|
|
|
notificationOldMessageEntry OBJECT-TYPE
|
|
SYNTAX NotificationOldMessageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "row of notification message parameters
|
|
Used by SAN/iQ 8.1 and earlier.
|
|
Obsolete in SAN/iQ 8.5.
|
|
Marked as current to increase compatability with some SNMP clients."
|
|
INDEX {
|
|
notificationIndex
|
|
}
|
|
::= { notificationOldMessageTable 1 }
|
|
|
|
NotificationOldMessageEntry ::= SEQUENCE {
|
|
notificationIndex
|
|
Unsigned32,
|
|
notificationMessage
|
|
DisplayString,
|
|
notificationTime
|
|
DateAndTime
|
|
}
|
|
|
|
notificationIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "notification message index
|
|
Used by SAN/iQ 8.1 and earlier.
|
|
Obsolete in SAN/iQ 8.5.
|
|
Marked as current to increase compatability with some SNMP clients."
|
|
::= { notificationOldMessageEntry 1 }
|
|
|
|
notificationMessage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "notification message contents
|
|
Used by SAN/iQ 8.1 and earlier.
|
|
Obsolete in SAN/iQ 8.5.
|
|
Marked as current to increase compatability with some SNMP clients."
|
|
::= { notificationOldMessageEntry 2 }
|
|
|
|
notificationTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "time notification occurred
|
|
Used by SAN/iQ 8.1 and earlier.
|
|
Obsolete in SAN/iQ 8.5.
|
|
Marked as current to increase compatability with some SNMP clients."
|
|
::= { notificationOldMessageEntry 3 }
|
|
|
|
userNotification NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
notificationMessage,
|
|
notificationTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A system event was generated.
|
|
The user chose to be notified of this condition
|
|
via SNMP. A table of messages exists which stores
|
|
all the notifications issued. This trap will
|
|
contain the OID referring to the corresponding
|
|
message stored in this table.
|
|
Used by SAN/iQ 8.1 and earlier.
|
|
Obsolete in SAN/iQ 8.5.
|
|
Marked as current to increase compatability with some SNMP clients."
|
|
::= { lhnNsmOldEvents 1 }
|
|
|
|
END
|
|
|
|