-- File: xylo-wan.mib
-- Bay Networks Annex Private Enterprise MIB
--
-- Copyright 1991, 1993, 1994, 1995, 1996, 1997 Bay Networks, Inc.
-- ALL RIGHTS RESERVED.
--
-- ALL RIGHTS RESERVED. Licensed Material - Property of Bay Networks, Inc.
-- This software is made available solely pursuant to the terms of a
-- software license agreement which governs its use.
-- Unauthorized duplication, distribution or sale are strictly prohibited.
--
-- This information is subject to change without notice, and should
-- not be construed as a commitment by Bay Networks, Inc. Bay Networks, Inc.,
-- assumes no responsibility for any errors that may appear in this
-- document.
--
-- $Id:
--
XYLO-WAN-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Counter
FROM RFC1155-SMI
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212
anxt1, anxpri, anxtunnelport, ss7,nfas
FROM XYLO-MIB-SMI;
-- xylogics OBJECT IDENTIFIER ::= { enterprises 15 }
-- anxt1 OBJECT IDENTIFIER ::= { annex 11 }
-- anxpri OBJECT IDENTIFIER ::= { annex 12 }
-- anxtunnelport OBJECT IDENTIFIER ::= { annex 14 }
-- ss7 OBJECT IDENTIFIER ::= { annex 109 }
-- nfas OBJECT IDENTIFIER ::= { annex 111 }
-- PRI related groups.
connections OBJECT IDENTIFIER ::= { anxpri 1 }
globals OBJECT IDENTIFIER ::= { anxpri 2 }
-- xylogics private mib group for CSMIM-T1 support
--the T1-engine/E1/PRI group
-- Note the following objects are applicable to T1/E1 or PRI except
-- where noted otherwise.
anxt1Total OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of T1/PRI lines on this Annex."
::= { anxt1 1 }
anxt1ConfigT1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Anxt1ConfigT1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of T1 configuration parameters that
are not included in the DS1 MIB."
::= { anxt1 2 }
anxt1ConfigT1Entry OBJECT-TYPE
SYNTAX Anxt1ConfigT1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The internal T1 engine parameters."
INDEX { anxt1LineIndex }
::= { anxt1ConfigT1Table 1 }
Anxt1ConfigT1Entry ::= SEQUENCE {
anxt1LineIndex INTEGER,
anxt1AlarmSyslog INTEGER,
anxt1DiiLineCode INTEGER,
anxt1DiiFraming INTEGER,
anxt1DiiDistance INTEGER,
anxt1Ds1LineBuildout INTEGER,
anxt1Ds1OnesDensity INTEGER,
anxt1EngineBypass INTEGER,
anxt1UnitId DisplayString,
anxt1UnitSerialNumber DisplayString,
anxt1UpTime INTEGER,
anxt1Info DisplayString,
anxt1TotChan INTEGER,
anxt1ResetPRI INTEGER,
anxt1SwitchType INTEGER,
anxt1BlockInCalls INTEGER,
anxt1BlockOutCalls INTEGER,
anxt1LineLength INTEGER,
anxt1AnalogEncoding INTEGER,
anxt1PRIModuleType INTEGER,
anxt1CasDnisDigits INTEGER,
anxt1CasAniDigits INTEGER,
anxt1CasDigitWidth INTEGER,
anxt1CasInterDigit INTEGER,
anxt1CasDigitPower1 INTEGER,
anxt1CasDigitPower2 INTEGER,
anxt1CasBusySignalBits INTEGER,
anxt1CasPhoneNumber DisplayString,
anxt1Dsx1LineType INTEGER,
anxt1Ds1EsfFdl INTEGER,
anxt1TniCircuitId DisplayString,
anxt1TniClock INTEGER,
anxt1CallbackEnable INTEGER,
anxt1CasAniEnable INTEGER,
anxt1Nfasinterfaceid INTEGER,
anxt1Backupinterfaceid INTEGER
}
anxt1LineIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213)."
::= { anxt1ConfigT1Entry 1 }
anxt1AlarmSyslog OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"If this object is set to yes(1), all
alarm events, red, yellow and blue, are
syslogged. In other words, the detection
of any one of the alarm events will
generate a syslog provided syslogs are
enabled. The default is yes(1).
Note:
1. The syslog is generated at warning level. That
means that anxSysLogMask should be atleast at Warning
level.
2. This object is supported for T1 modules only.
Corresponding na/admin parameter would be alarmsyslog."
::= { anxt1ConfigT1Entry 2 }
anxt1DiiLineCode OBJECT-TYPE
SYNTAX INTEGER {
b8zs(1),
ami(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object selects the line code format
used on the T1 Drop and Insert Interface.
tni_line_coding is the na/admin corresponding
parameter. This object is supported for T1 modules only.
Note: For modules configured for PRI,
b8zs is the only valid option.
ami is valid only for channelized E1"
::= { anxt1ConfigT1Entry 3 }
anxt1DiiFraming OBJECT-TYPE
SYNTAX INTEGER {
esf(1),
d4(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object controls the super frame format
used on the T1 Drop and Insert Interface.
tdi_framing is the na/admin corresp. parameter.
This object is supported for T1 modules only.
Note: For modules configured for PRI,
esf(1) is the only valid option."
::= { anxt1ConfigT1Entry 4 }
anxt1DiiDistance OBJECT-TYPE
SYNTAX INTEGER (0..655)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The distance measured in feet of the cable
run to the equipment attached to the Drop
and Insert Interface. The default is 0.
tdi_distance is the corresp. na/admin parameter.
This object is supported for T1 modules only."
::= { anxt1ConfigT1Entry 5 }
anxt1Ds1LineBuildout OBJECT-TYPE
SYNTAX INTEGER {
zero-db(1),
sevendotfive-db(2),
fifteen-db(3),
twentytwodotfive-db(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"At instalation time, the telephone company
will supply a measured cable loss measurement
between the last line generator and the
customer location. This value, named line
buildout, is measured in db and may range
from 0 and 22.5 dbs.
tni_line_buildout is the corresp. na/admin parameter.
This object is supported for T1 modules only."
::= { anxt1ConfigT1Entry 6 }
anxt1Ds1OnesDensity OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object allows the user to defeat
the ones density monitor.
The default is off but it should be
set to on when using the AMI line coding.
tni_ones_density would be corresp. na/admin parameter.
This object is supported for T1 modules only."
::= { anxt1ConfigT1Entry 7 }
anxt1EngineBypass OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"when this object is set to yes the T1 engine
is taken out of the network. The Network
Interface is then physically coupled to
the Drop and Insert Interface, and the T1
engine has no effect on the T1 circuit.
bypass is the corresp. na/admin paramter.
This object is supported for T1 modules only."
::= { anxt1ConfigT1Entry 8 }
anxt1UnitId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a string indicating the firmware
version for the T1/PRI engine."
::= { anxt1ConfigT1Entry 9 }
anxt1UnitSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This is the 4 digit T1 engine serial number.
This object is supported for T1 modules only."
::= { anxt1ConfigT1Entry 10 }
anxt1UpTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Indicates the up time in minutes for the T1 engine.
Doing a hard reset will reset this value.
Note: This value may not be same as sysupTime if a
hard reset has been done at any time after the annex
is brought up.
This object is supported for T1 modules only."
::= { anxt1ConfigT1Entry 11 }
anxt1Info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This objct specifies installation information
from the telephone company regarding the T1 line.
Corresponding na/admin parameter is t1_info.
This object is supported for T1 modules only."
::= { anxt1ConfigT1Entry 12 }
anxt1TotChan OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of internal DS0 channels on this WAN interface."
::= { anxt1ConfigT1Entry 13 }
anxt1ResetPRI OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to enable will reset the PRI
line. Setting the object to disable(2) will
disable the PRI line and make it unavailable."
::= { anxt1ConfigT1Entry 14 }
anxt1SwitchType OBJECT-TYPE
SYNTAX INTEGER {
default(1),
other(2),
sng(3),
ni2(4),
dms(5),
at9(6),
ets(7),
au1(8),
notused1(9),
ntt(10),
ets-ncrc4(11),
ust1(12),
hkt1(13),
twt1r1(14),
bbe1r2(15),
at4(16),
bre1r2(17),
kre1r2-1(18),
swe1p7(19),
ine1r2(20),
cne1r2(21),
nze1r2(22),
ust1fd(23),
ess-v10(24),
nosig(25),
br2e1r2(26),
kre1r2-2(27),
ide1r2(28),
phe1r2(29),
the1r2(30),
mye1r2(31),
are1r2(32),
mxe1r2(33),
ane1r2(34),
tre1r2(35),
ile1r2(36),
moe1r2(37),
ine1r2-1(38),
ine1r2-2(39),
ine1r2-3(40),
ine1r2-4(41),
twt1(42),
ust1fc(43),
ust1fdi(44),
ni2_nfas_primary(45),
ni2_nfas_backup(46),
dms_nfas_primary(47),
dms_nfas_backup(48)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the switch type compatibile with the
PRI service provider.
default(1) Will select the default switch chosen by the wan
manager based on the moduletype. If you set the
switchtype to default(1), reboot the box, and do an
snmpget on the switchtype, you can determine which
switchtype was chosen by the wan manager.
other(2) - For a GET, this value reflects the switch
type set through Cli/Admin which does not
match with other switches listed here.
For a SET the SNMP agent will ignore it
and will not change the current switch type
set through Cli/Admin.
switch_type description protocol
___________________________________________________________________
sng(3), Singapore E1 ISDN PRI
ni2(4), NI-2 (National ISDN 2) T1 ISDN PRI
dms(5), DMS-100 (Northern Telecom) T1 ISDN PRI
at9(6), 5ESS (AT&T 5ESS) T1 ISDN PRI
ets(7), ETSI E1 ISDN PRI
au1(8), Australia/AUSTEL E1 PRI PRI
ntt(10), Japan NTT PRI
ets-ncrc4(11), ETSI E1 ISDN w/o CRC4 PRI
ust1(12), US/North American Channelized T1 CAS
hkt1(13), Hong Kong Channelized T1 CAS
twt1r1(14), Taiwan T1/R1 CAS
bbe1r2(15), BlueBook/CCITT E1/R2 CAS
at4(16), 4ESS (AT&T 4ESS) T1 ISDN PRI
bre1r2(17), Brazil E1/R2 CAS
kre1r2-1(18), Korea E1/R2 CAS
swe1p7(19) Sweden E1 P7 CAS
ine1r2(20), Indonesia E1/R2 CAS
cne1r2(21), China E1/R2 CAS
nze1r2(22), New Zealand E1/R2 CAS
ust1fd(23), Unites States CAS
ess-v10(24),
nosig(25), SS7, No signaling required SS7
br2e1r2(26), Brazil E1/R2, 1 second wink CAS
kre1r2-2(27), Korea E1/R2 CAS
ide1r2(28), Indonesia CAS
phe1r2(29), Philippines CAS
the1r2(30), Thailand CAS
mye1r2(31), Malaysia CAS
are1r2(32), Argentina CAS
mxe1r2(33), Mexico CAS
ane1r2(34), St.Martin-Antilles CAS
tre1r2(35), Turkey CAS
ile1r2(36), Israel CAS
moe1r2(37), Macau CAS
ine1r2-1(38), India sig1 CAS
ine1r2-2(39), India sig2 CAS
ine1r2-3(40), India sig3 CAS
ine1r2-4(41), India sig4 CAS
twt1(42), Taiwan (wink) CAS
ust1fc(43), Unites States CAS
ust1fdi(44), Unites States CAS
ni2_nfas_primary(45), NI-2 (National ISDN 2) T1 ISDN PRI
ni2_nfas_backup(46), NI-2 (National ISDN 2) T1 ISDN PRI
dms_nfas_primary(47), DMS-100 (Northern Telecom) T1 ISDN PRI
dms_nfas_backup(48) DMS-100 (Northern Telecom) T1 ISDN PRI
This parameter is available on all platforms using
PRI module and platforms using the WAN module
configured for CAS or PRI. You must reset the box
for the new switch_type to take effect"
::= { anxt1ConfigT1Entry 15 }
anxt1BlockInCalls OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this object is set to enable, then the box
will stop accepting calls on this line. This will
prevent new users from logging in and should be used
to bring the box down gracefully. The default
is disable.
This object is supported for modules configured
for PRI."
::= { anxt1ConfigT1Entry 16 }
anxt1BlockOutCalls OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this object is set to enable, then the box
will not place any outgoing calls. This should be used
to bring the box down gracefully. The default
is disable.
This object is supported for modules configured
for PRI."
::= { anxt1ConfigT1Entry 17 }
anxt1LineLength OBJECT-TYPE
SYNTAX INTEGER {
r0-25(1),
r26-65(2),
r66-100(3),
r101-135(4),
r136-165(5),
r166-185(6),
r186-210(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter allows the user to configure
the dsx1 line driver with the distance
between the annex and the external CSU. This paramater
should be left to default with annex's with internal CSU.
The parameter defines the line length in meters.
This MIB object corresponds to the na/admin
parameter dsx1_line_length.
This parameter is available on the ra6300, and on platforms
using the WAN module configured for CAS or PRI."
::= { anxt1ConfigT1Entry 18 }
anxt1AnalogEncoding OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
mu-law(2),
a-law(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the type of encoding
to be used for analog (modem) calls. If this parameter
is not set then RA6300 will determine itself depending
on the PRI line that it terminates. For PRI line in
USA, this is set to mu-law and in Europe this will be
set to a-law.
This MIB object corresponds to the na/admin
parameter analog_encoding.
Default value is auto(1).
This parameter is available on the ra6300, and on platforms
using the WAN module configured for CAS or PRI."
::= { anxt1ConfigT1Entry 19 }
anxt1PRIModuleType OBJECT-TYPE
SYNTAX INTEGER {
e1(1),
t1(2),
t1-intcsu(3),
e1-aust(4),
unused(5),
unused1(6),
unused2(7),
cas-t1-csu(8),
cas-e1(9),
sng-e1(10),
pri-e1-israel(11),
type-unknown(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the module type on .
e1(1) means PRI module is for Europe,
t1(2) means PRI module is for USA with External CSU,
t1-intcsu(3) t1/PRI for USA with internal CSU.
e1-aust(4) e1/PRI for Australia.
cas-t1-csu(8) t1/CAS with internal csu.
cas-e1(9) e1/CAS.
This parameter is available on all platforms using
PRI module and platforms using the WAN module
configured for CAS or PRI. "
::= { anxt1ConfigT1Entry 20 }
anxt1CasDnisDigits OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter allows the user to configure the number of
DNIS digits that the channelized T1/E1 interface is provisioned
to provide. The default value is 0.
Typical values are between 4 - 10.
This MIB object corresponds to the na/admin
parameter dnis.
This parameter is available on platforms
using the WAN module configured for CAS."
::= { anxt1ConfigT1Entry 21 }
anxt1CasAniDigits OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter allows the user to configure the number of
ANI digits that the channelized T1/E1 interface is provisioned
to provide. The default value is 0.
Typical values are between 4 - 10.
This MIB object corresponds to the na/admin
parameter ani.
This parameter is available on platforms
using the WAN module configured for CAS."
::= { anxt1ConfigT1Entry 22 }
anxt1CasDigitWidth OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter allows the width of each digit generated by
the WAN module to be adjusted. The default value is 0.
This MIB object corresponds to the na/admin
parameter digit_width.
This parameter is available on platforms
using the WAN module configured for CAS."
::= { anxt1ConfigT1Entry 23 }
anxt1CasInterDigit OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter allows the distance between each digit
generated by the WAN module to be adjusted. The default
value is 0.
This MIB object corresponds to the na/admin
parameter inter_digit.
This parameter is available on platforms
using the WAN module configured for CAS."
::= { anxt1ConfigT1Entry 24 }
anxt1CasDigitPower1 OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter allows the power level of the FIRST tone
of each digit generated by the WAN module to be adjusted.
The default value is 0.
This MIB object corresponds to the na/admin
parameter digit_power_1.
This parameter is available on platforms
using the WAN module configured for CAS."
::= { anxt1ConfigT1Entry 25 }
anxt1CasDigitPower2 OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter allows the power level of the SECOND tone
of each digit generated by the WAN module to be adjusted.
The default value is 0.
This MIB object corresponds to the na/admin
parameter digit_power_2.
This parameter is available on platforms
using the WAN module configured for CAS."
::= { anxt1ConfigT1Entry 26 }
anxt1CasBusySignalBits OBJECT-TYPE
SYNTAX INTEGER {
bits00(1),
bits01(2),
bits10(3),
bits11(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An enumerated integer that defines the type of
busy signal.
This MIB object corresponds to the na/admin
parameter busy_signal_bits.
This parameter is available on platforms using the
WAN module configured for CAS."
::= { anxt1ConfigT1Entry 27 }
anxt1CasPhoneNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The local phone number of the WAN interface.
This MIB object corresponds to the na/admin parameter
local_phone_number.
This parameter is available on platforms using the
WAN module configured for CAS."
::= { anxt1ConfigT1Entry 28 }
anxt1Dsx1LineType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
eSF(2),
d4(3),
dDF(4),
mFF-CRC4(5),
mFF-CRC4-G706(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable indicates the variety of DS1
Line implementing this circuit. The type of
circuit affects the number of bits per second
that the circuit can reasonably carry, as well
as the interpretation of the usage and error
statistics. The values, in sequence, describe:
TITLE: rfc1406 TITLE: SPECIFICATION:
ESF(2) dsx1ESF Extended SuperFrame DS1
D4(3) dsx1D4 AT&T D4 format DS1
DDF(4) dsx1E1/ CCITT Recommendation G.704
dsxE1-MF (Table 4a)
MFF-CRC4(5) dsx1E1-CRC/ CCITT Recommendation G.704
dsx1E1-CRC-MF (Table 4b)
MFF-CRC4-G706(6) N/A 5399 WAN Module Func. Spec."
::= { anxt1ConfigT1Entry 29 }
anxt1Ds1EsfFdl OBJECT-TYPE
SYNTAX INTEGER {
att(1),
ansi(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The NA parameter is tni_esf_fdl (channelized T1 category):
This specifies one of two standards when running ESF framing
on the T1 Network Interface: Valid options are ansi, att "
::= { anxt1ConfigT1Entry 30 }
anxt1TniCircuitId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The NA parameter is tni_circuit_id (channelized T1 category):
This is a ascii string with circuit id provided by the
telephone company. Up to 127 bytes.
This object is supported for T1 engines only."
::= { anxt1ConfigT1Entry 31 }
anxt1TniClock OBJECT-TYPE
SYNTAX INTEGER {
loop(1),
local(2),
external(3)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The NA parameter is tni_clock (channelized T1 category):
This specifies the T1 engine clock source: loop, local,
external.
This object is supported for T1 engines only."
::= { anxt1ConfigT1Entry 32 }
anxt1CallbackEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this object is set to enable, the WAN interface may be
selected to handle a callback pending port availability.
When set to disable, the associated WAN interface cannot be
selected as a callback resource. The default is disable.
This MIB object corresponds to the NA/admin WAN
parameter 'callback_enable'."
::= { anxt1ConfigT1Entry 33 }
anxt1CasAniEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter allows the user to configure whether or not to
allow CAS ANI digits, (per provisioning). The default is disable.
This MIB object corresponds to the na/admin WAN
parameter 'ani'.
This parameter is available on platforms
using the WAN module configured for CAS."
::= { anxt1ConfigT1Entry 34 }
anxt1Nfasinterfaceid OBJECT-TYPE
SYNTAX INTEGER (0..19)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is a configurable parameter for NFAS.
This MIB object corresponds to the NA/admin WAN
parameter 'nfas_interface_id'."
::= { anxt1ConfigT1Entry 35 }
anxt1Backupinterfaceid OBJECT-TYPE
SYNTAX INTEGER (1..19)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is a configurable parameter for NFAS.
This MIB object corresponds to the NA/admin WAN
parameter 'backup_interface_id'."
::= { anxt1ConfigT1Entry 36 }
-- The DS0's group
anxt1ChanTable OBJECT-TYPE
SYNTAX SEQUENCE OF Anxt1ChanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of DS0 channel entries."
::= { anxt1 3 }
anxt1ChanEntry OBJECT-TYPE
SYNTAX Anxt1ChanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The internal T1 engine parameters."
INDEX { anxt1ChanIndex, anxt1ChanNumber }
::= { anxt1ChanTable 1 }
Anxt1ChanEntry ::= SEQUENCE {
anxt1ChanIndex INTEGER,
anxt1ChanNumber INTEGER,
anxt1ChanMap OCTET STRING,
anxt1ChanSigProto INTEGER,
anxt1ChanRing INTEGER,
anxt1ChanIpAddr IpAddress,
anxt1ChanIpxNetwork DisplayString,
anxt1ChanIpxNode DisplayString,
anxt1ChanStatus INTEGER,
anxt1ChanState INTEGER,
anxt1ChanSeize Counter,
anxt1ChanRingCount Counter,
anxt1ChanAssign Counter,
anxt1ChanConnect Counter,
anxt1ChanChat Counter,
anxt1ChanDcd Counter,
anxt1ChanModemCall Counter,
anxt1ChanConsecFail Counter
}
anxt1ChanIndex OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
WAN interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module."
::= { anxt1ChanEntry 1 }
anxt1ChanNumber OBJECT-TYPE
SYNTAX INTEGER (1..24)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique number from 1 to anxt1TotChan that
identifies each internal DS0 channel on a WAN interface."
::= { anxt1ChanEntry 2 }
anxt1ChanMap OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object specifies the mapping between the DS0
in the DS1 interface, the DS0 in the DI interface,
and the modems. The DS0 is identified by anxt1ChanIfIndex
and anxt1ChanNumber. This object has two 8-bit fields.
The high byte specifies the mapping:
unused(1),
ds1_modem(2), (ds1 to modem)
di_modem(3), (di to modem)
voice(4), (ds1 to di with voice signaling)
data(5) (ds1 to di with data signaling)
The low byte is used only when the high byte specifies
ds1_modem or di_modem and should be ignored in all other
cases. The low byte specifies the modem number (same as
port number) being mapped to the DS0.
Note: when the type is set to either voice, data or unused
agent expects zeros in the modem octet eg:'0400'
Corresp. na/admin parameter is the map.
This object is only valid for T1 products."
::= { anxt1ChanEntry 3 }
anxt1ChanSigProto OBJECT-TYPE
SYNTAX INTEGER {
loop-loop(22),
loop-none(21),
none-loop(12),
ground-ground(33),
ground-none(31),
none-ground(13),
wink-wink(44),
wink-none(41),
none-wink(14),
immed-none(51),
none-immed(15),
none-none(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is meaningful only when anxt1ChanMap is set
to ds1_modem or di_modem and should be ignored in all
other cases. The supported protocols are:
none(1),
loop_start(2),
ground_start(3),
wink_start(4),
immediate_start(5)
Note: following combinations are considered valid:
Value InSig octet OutSig octet
----- ----------- ------------
22 loop_start loop_start
21 loop_start none
12 none loop_start
33 ground ground
31 ground none
13 none ground
44 wink wink
41 wink none
14 none wink
51 immediate none
15 none immediate
11 none none
sigproto is the na/admin corresponding parameter.
This object is not valid for RA6300 only."
::= { anxt1ChanEntry 4 }
anxt1ChanRing OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
diable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is meaningful only when anxt1ChanMap is set
to ds1-modem or di-modem and should be ignored in all
other cases. This object specifies if the Annex should
provide the audible ring to the central office on incoming
calls. The default is NO.
Corresp. na/admin parameter is the ring.
This parameter is available on the ra6300, and on platforms
using the WAN module configured for PRI."
::= { anxt1ChanEntry 5 }
anxt1ChanIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object returns the IP address
associated with the B Channel. When needed, this
IP address will be used for calls over the B channel.
This parameter is available on the ra6300, and on platforms
using the WAN module (configured for CAS or PRI)."
::= { anxt1ChanEntry 6 }
anxt1ChanIpxNetwork OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IPX network number for an IPX PPP connection
using this port. When the IPX PPP connection is
established the network number will be negotiated.
If one end of the connection is set to zero then
the value from the other end of the connection will
be used.
The value of this object is an 8 digit hexadecimal
number string representing the IPX network segment
assigned to this port. The value must be unique
across the network domain.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ppp_ipx_network'."
::= { anxt1ChanEntry 7 }
anxt1ChanIpxNode OBJECT-TYPE
SYNTAX DisplayString (SIZE(11..17))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IPX node number for an IPX PPP connection
using this port.
The value of this object is a 12 digit
hexadecimal number string representing the IPX
node number assigned to this port.
Note the string is expected in the form:
12-3a-4-7-89-23.Each part of the address
must be a hex value separated by a hyphen.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ppp_ipx_node'."
::= { anxt1ChanEntry 8 }
anxt1ChanStatus OBJECT-TYPE
SYNTAX INTEGER {
used(1),
unused(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the status of the
B channel. This is a read-only object that
indicates whether the channel is in use or not."
::= { anxt1ChanEntry 9 }
anxt1ChanState OBJECT-TYPE
SYNTAX INTEGER {
available(1),
busied-out(2),
auto-busied-out(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object reflects the state of the
B channel. Available means it is open
for use, busied-out means it was manually
taken out of the pool for use, and
auto-busied-out means the box removed
this channel for use because there are
more channels than modems available.
This object can be set and changes the state of
the channel. auto-busied-out cannot be set by a user."
::= { anxt1ChanEntry 10 }
anxt1ChanSeize OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SEIZE message from a WAN module to a WAN
manager process on the main processor,
indicating that the central office switch
has sent a channelized T1/E1 seize event."
::= { anxt1ChanEntry 11 }
anxt1ChanRingCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RING message from a WAN module to a WAN
manager process on the main processor,
indicating that a call has arrived. Successful
completion of assigning a modem and starting a
session."
::= { anxt1ChanEntry 12 }
anxt1ChanAssign OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"No modems were available for assignment.
This is caused by not having enough modems
or modems being removed from the pool "
::= { anxt1ChanEntry 13 }
anxt1ChanConnect OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CONNECT message from the WAN module to the
WAN manager process, meaning the 5399 has
accepted the call and the WAN module and the
telephone company switch have agreed that the
call is up."
::= { anxt1ChanEntry 14 }
anxt1ChanChat OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"There was a modem error and the call was
terminated. Possibly caused by the modem."
::= { anxt1ChanEntry 15 }
anxt1ChanDcd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Modem did not establish a connection with
it's peer. Lots of possible causes:
many possible causes:
modem error
bad data from bad channel
end-to-end line quality low
caller hung up
calling device wasn't a modem "
::= { anxt1ChanEntry 16 }
anxt1ChanModemCall OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times an incoming modem
call failed before getting all the way
to DCD."
::= { anxt1ChanEntry 17 }
anxt1ChanConsecFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times an incoming non-modem
call failed before successfully assigning
a device."
::= { anxt1ChanEntry 18 }
-- The extended current statistics group
-- This table is available only on WAN module platforms.
anxt1CurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Anxt1CurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of extended T1 current statistics.
This table is valid for WAN module platforms only."
::= { anxt1 4 }
anxt1CurrentEntry OBJECT-TYPE
SYNTAX Anxt1CurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The internal T1 engine extended current statistics."
INDEX { anxt1CurrentIndex }
::= { anxt1CurrentTable 1 }
Anxt1CurrentEntry ::= SEQUENCE {
anxt1CurrentIndex INTEGER,
anxt1CurrentOofs Counter,
anxt1CurrentBpvs Counter,
anxt1CurrentCrcs Counter,
anxt1CurrentCs Counter,
anxt1CurrentRnacs Counter,
anxt1CurrentEsfs Counter,
anxt1CurrentLofcs Counter
}
anxt1CurrentIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { anxt1CurrentEntry 1 }
anxt1CurrentOofs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An Out Of Frame (OOF) event begins when any two
of four consecutive frame synchronizing bits are
received from the network interface are incorrect.
An OOF state ends when reframe occurs."
::= { anxt1CurrentEntry 2 }
anxt1CurrentBpvs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A BiPolar Violations error event for an AMI-coded
signal is the occurence of a pulse of the same polarity
as the previous pulse. A BPV error event for a B8ZS or
HDB3 coded signal is the occurence of a pulse of the
same polarity as the previous pulse without being a
part of the zero substitution code."
::= { anxt1CurrentEntry 3 }
anxt1CurrentCrcs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A CRC error occurs when the CRC field calculated
by the customer installation, based on the incoming
DS1 signal does not agree with the CRC field contained
in the DS1 signal received from the network."
::= { anxt1CurrentEntry 4 }
anxt1CurrentCs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A Controlled Slips is the occcurence of a replication
or deletion of a DS1 frame by the receiving terminal."
::= { anxt1CurrentEntry 5 }
anxt1CurrentRnacs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive Network Alarm seconds is the count of seconds
with at least one alarm event occurring in a second."
::= { anxt1CurrentEntry 6 }
anxt1CurrentEsfs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of extended superframe errors in the current
interval."
::= { anxt1CurrentEntry 7 }
anxt1CurrentLofcs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of loss of framing errors in the current
interval."
::= { anxt1CurrentEntry 8 }
-- The extended total statistics group
-- This table is available on WAN module platforms only.
anxt1IntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Anxt1IntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of extended T1 interval statistics.
This table is valid for WAN module platforms only."
::= { anxt1 5 }
anxt1IntervalEntry OBJECT-TYPE
SYNTAX Anxt1IntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The internal T1 engine extended interval statistics."
INDEX { anxt1IntervalIndex, anxt1IntervalNumber }
::= { anxt1IntervalTable 1 }
Anxt1IntervalEntry ::= SEQUENCE {
anxt1IntervalIndex INTEGER,
anxt1IntervalNumber INTEGER,
anxt1IntervalOofs Counter,
anxt1IntervalBpvs Counter,
anxt1IntervalCrcs Counter,
anxt1IntervalCs Counter,
anxt1IntervalRnacs Counter,
anxt1IntervalEsfs Counter,
anxt1IntervalLofcs Counter
}
anxt1IntervalIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { anxt1IntervalEntry 1 }
anxt1IntervalNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { anxt1IntervalEntry 2 }
anxt1IntervalOofs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An Out Of Frame (OOF) event begins when any two
of four consecutive frame synchronizing bits are
received from the network interface are incorrect.
An OOF state ends when reframe occurs."
::= { anxt1IntervalEntry 3 }
anxt1IntervalBpvs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A BiPolar Violations error event for an AMI-coded
signal is the occurence of a pulse of the same polarity
as the previous pulse. A BPV error event for a B8ZS or
HDB3 coded signal is the occurence of a pulse of the
same polarity as the previous pulse without being a
part of the zero substitution code."
::= { anxt1IntervalEntry 4 }
anxt1IntervalCrcs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A CRC error occurs when the CRC field calculated
by the customer installation, based on the incoming
DS1 signal does not agree with the CRC field contained
in the DS1 signal received from the network."
::= { anxt1IntervalEntry 5 }
anxt1IntervalCs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A Controlled Slips is the occcurence of a replication
or deletion of a DS1 frame by the receiving terminal."
::= { anxt1IntervalEntry 6 }
anxt1IntervalRnacs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive Network Alarm seconds is the count of seconds
with at least one alarm event occurring in a second."
::= { anxt1IntervalEntry 7 }
anxt1IntervalEsfs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of extended superframe errors in this interval."
::= { anxt1IntervalEntry 8 }
anxt1IntervalLofcs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of loss of framing errors in this interval."
::= { anxt1IntervalEntry 9 }
-- The extended total statistics group
-- Table is available on WAN module platforms only.
anxt1TotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Anxt1TotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of extended T1 total statistics.
This table is valid for WAN module platforms only."
::= { anxt1 6 }
anxt1TotalEntry OBJECT-TYPE
SYNTAX Anxt1TotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The internal T1 engine extended total statistics."
INDEX { anxt1TotalIndex }
::= { anxt1TotalTable 1 }
Anxt1TotalEntry ::= SEQUENCE {
anxt1TotalIndex INTEGER,
anxt1TotalOofs Counter,
anxt1TotalBpvs Counter,
anxt1TotalCrcs Counter,
anxt1TotalCs Counter,
anxt1TotalRnacs Counter,
anxt1TotalEsfs Counter,
anxt1TotalLofcs Counter
}
anxt1TotalIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { anxt1TotalEntry 1 }
anxt1TotalOofs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An Out Of Frame (OOF) event begins when any two
of four consecutive frame synchronizing bits are
received from the network interface are incorrect.
An OOF state ends when reframe occurs."
::= { anxt1TotalEntry 2 }
anxt1TotalBpvs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A BiPolar Violations error event for an AMI-coded
signal is the occurence of a pulse of the same polarity
as the previous pulse. A BPV error event for a B8ZS or
HDB3 coded signal is the occurence of a pulse of the
same polarity as the previous pulse without being a
part of the zero substitution code."
::= { anxt1TotalEntry 3 }
anxt1TotalCrcs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A CRC error occurs when the CRC field calculated
by the customer installation, based on the incoming
DS1 signal does not agree with the CRC field contained
in the DS1 signal received from the network."
::= { anxt1TotalEntry 4 }
anxt1TotalCs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A Controlled Slips is the occcurence of a replication
or deletion of a DS1 frame by the receiving terminal."
::= { anxt1TotalEntry 5 }
anxt1TotalRnacs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive Network Alarm seconds is the count of seconds
with at least one alarm event occurring in a second."
::= { anxt1TotalEntry 6 }
anxt1TotalEsfs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total count of extended superframe errors."
::= { anxt1TotalEntry 7 }
anxt1TotalLofcs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total count of loss of framing errors."
::= { anxt1TotalEntry 8 }
-- anxt1WanModuleTable
anxt1WanModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF Anxt1WanModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table is is used to cross reference a WAN
module to its ifindex."
::= { anxt1 7 }
anxt1WanModuleEntry OBJECT-TYPE
SYNTAX Anxt1WanModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN module table entry."
INDEX { anxt1WanIndex }
::= { anxt1WanModuleTable 1 }
Anxt1WanModuleEntry ::= SEQUENCE {
anxt1WanIndex INTEGER,
anxt1WanIfIndex INTEGER
}
anxt1WanIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the index of the physical WAN module in
any BAY remote access product that uses WAN modules.
The range is 1 - anxt1Total (number of WAN modules in box)"
::= { anxt1WanModuleEntry 1 }
anxt1WanIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"This object can be used in place of Ifindex to find
the interface number of a WAN module."
::= { anxt1WanModuleEntry 2 }
anxt1TotalChannels OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of channels (Ds0's) on the this box
(or blade)."
::= { anxt1 8}
anxt1BusiedOutChannels OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of channels that are busied out.
anxt1TotalChannels - anxt1BusiedOutChannels =
Number of available channels"
::= { anxt1 9}
wanStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Wan Module statistics.
This table is valid for WAN module platforms only."
::= { anxt1 10 }
wanStatEntry OBJECT-TYPE
SYNTAX WanStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The internal T1 engine extended current statistics."
INDEX { wanStatIndex }
::= { wanStatTable 1 }
WanStatEntry ::= SEQUENCE {
wanStatIndex INTEGER,
wanStatInterfaceErrs Counter,
wanStatAcceptedInCalls Counter,
wanStatRejectedInCalls Counter,
wanStatAcceptedOutCalls Counter,
wanStatRejectedOutCalls Counter,
wanStatNormalCallDisconnects Counter,
wanStatAbNormalCallDisconnects Counter,
wanStatBchansCurrAllocated INTEGER,
wanStatNumTimesWanFull Counter
}
wanStatIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex value in the interfaces
table.
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { wanStatEntry 1 }
wanStatInterfaceErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when ever an
error occurs between the wan module and the
PRI manager."
::= { wanStatEntry 2 }
wanStatAcceptedInCalls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of incoming calls accepted by the call handler.
(call handler is generic term for all types of signaling
methods)"
::= { wanStatEntry 3 }
wanStatRejectedInCalls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of incoming calls rejected by the call handler.
(call handler is generic term for all types of signaling
methods)"
::= { wanStatEntry 4 }
wanStatAcceptedOutCalls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of outgoing calls accepted by the call handler.
(call handler is generic term for all types of signaling
methods)"
::= { wanStatEntry 5 }
wanStatRejectedOutCalls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of outgoing calls rejected by the call handler.
(call handler is generic term for all types of signaling
methods)"
::= { wanStatEntry 6 }
wanStatNormalCallDisconnects OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of normal disconnects.
Normal Disconnects cause codes:
- NORMAL_CALL_CLEARING_CCOD"
::= { wanStatEntry 7 }
wanStatAbNormalCallDisconnects OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of abnormal disconnects.
Abnormal Disconnects cause codes:
- INVALID_NUMBER_FORMAT_CCODE
- NO_CKT_CHAN_AVAIL_CCODE
- REQ_CHAN_NOT_AVAIL_CCODE"
::= { wanStatEntry 8 }
wanStatBchansCurrAllocated OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of B channels currently allocated."
::= { wanStatEntry 9 }
wanStatNumTimesWanFull OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times this wan has had all B channels
allocated since the wan_manager process was started
on the wan module. The wan_manager process is
started at boot time or by using the cli
-control- command to stop it and restart
it on a given wan module."
::= { wanStatEntry 10 }
-- PRI related groups.
-- Call connection table.
-- Active connection/call parameter group.
-- Only the active connection/call on a B channel will be returned.
-- All the tables in this group are indexed by line.channel number.
callGenericTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallGenericEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries of generic parameters for
active calls."
::= { connections 1 }
callGenericEntry OBJECT-TYPE
SYNTAX CallGenericEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The call's generic parameters."
INDEX { callGenericLineIdx, callGenericIdx }
::= { callGenericTable 1 }
CallGenericEntry ::= SEQUENCE {
callGenericLineIdx INTEGER,
callGenericIdx INTEGER,
callGenericMode INTEGER,
callGenericLocation DisplayString,
callGenericTermVar DisplayString,
callGenericPrompt DisplayString,
callGenericAllowBcast INTEGER,
callGenericImask7Bits INTEGER,
callGenericCliImask7 INTEGER,
callGenericBanner INTEGER,
callGenericTcpKeepAlive INTEGER,
callGenericDedicatedArgs DisplayString,
callGenericModemVar DisplayString,
callGenericDefSessMode INTEGER,
callGenericResolveProtocol INTEGER,
callGenericMaxSession INTEGER,
callGenericSpeed DisplayString,
callGenericAutoBaud INTEGER,
callGenericJobs DisplayString,
callGenericLineType INTEGER
}
callGenericLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callGenericEntry 1 }
callGenericIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callGenericEntry 2 }
callGenericMode OBJECT-TYPE
SYNTAX INTEGER {
cli(1),
slave(2),
adaptive(3),
unused(4),
slip(5),
ppp(7),
arap(8),
invalid(9),
auto-detect(10),
auto-adapt(11),
ipx(13),
call(14),
connect(15),
rlogin(16),
telnet(17),
tn3270(18)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mode assigned to the port. Valid only
if the port type is async, or ta. The default
is cli.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'mode'.
Note: Values 6 and 12 are not used."
::= { callGenericEntry 3 }
callGenericLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A descriptive string for this port. This
string is displayed by the CLI who command.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
location."
::= { callGenericEntry 4 }
callGenericTermVar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A string defining the type of terminal
attached to the serial/ta port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'term_var'.
Note: This object is not valid if the port type
is synchronous."
::= { callGenericEntry 5 }
callGenericPrompt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter defines a port-specific prompt
string. The prompt string consists of displayable
characters and embedded formatting codes. Each
formatting code is stored in a single character
in nonvolatile memory. The maximum number of
characters stored for the prompt string
is 16. Since the formatting codes consist of
a '%' prepended to a single character, the maximum
length string that may be entered for this object
is 32 characters. Strings less than 32
characters in length will be rejected as bad values
if they cannot be stored into 16 characters in
nonvolatile memory after the formatting codes are
compressed into single characters.
The valid formatting codes are:
%a the string 'annex'
%c the string ': '
%d the date and time
%i the Annex's IP address
%j a newline character
%l port location, or 'port n'
%n the Annex's name
%p the port number
%r the string 'port'
%s a space
%t the time hh:mm:ss
%u the user name for port
%% the string '%'
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'prompt'.
Note: This object is not valid for
synchronous ports."
::= { callGenericEntry 6 }
callGenericAllowBcast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Controls whether the serial/ta port can
receive administrative broadcast messages.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'allow_broadcast'.
Note: This object is not valid for
synchronous ports."
::= { callGenericEntry 8 }
callGenericImask7Bits OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When enabled, instructs the Annex to ignore
the eighth bit of all received characters
on the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'imask_7bits'.
Note: This object is not valid for Synchronous ports."
::= { callGenericEntry 10 }
callGenericCliImask7 OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines whether input at the CLI is masked to
7 bits. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'cli_imask7' The
default value for this object is enabled.
Note: This object is not valid for Synchronous ports."
::= { callGenericEntry 11 }
callGenericBanner OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
beforesec(3),
aftersec(4),
motd-before-sec(5),
motd-after-sec(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies whether the Annex banner and message-
of-the-day are displayed on the channel. The
default is enabled.
This has four possible actions:
default, Y, yes, unset: banner before security,
motd after
none, N: no banner or motd
beforesec: banner and motd before
security
aftersec: banner and motd after
security
motd-before-sec: motd before security; no
banner
motd-after-sec: motd after security; no
banner
This MIB object corresponds to the NA/admin
NA/Admin Global Port parameter 'banner'.
Note: This object is not valid for Synchronous ports."
::= { callGenericEntry 12 }
callGenericTcpKeepAlive OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The default keep-alive value for connections
to this serial port. If this is zero, use the
value specified by anxTcpKeepAlive.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'tcp_keepalive'.
Note: This object is not valid for Synchronous ports."
::= { callGenericEntry 13 }
callGenericDedicatedArgs OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Command line arguments passed to process
started by a dedicated port with mode set
to 'telnet', 'tn3270', 'rlogin', 'connect'
(if LAT is in use) or 'call'. This object is
not valid for TA ports.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'dedicated_arguments'.
Note: This object is not valid for Synchronous ports."
::= { callGenericEntry 14 }
callGenericModemVar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A string defining the type of modem attached
to the serial port. This object is not valid
for TA ports. This is always set to
'microcom'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'type_of_modem'.
Note: This object is not valid for
synchronous ports."
::= { callGenericEntry 15 }
callGenericDefSessMode OBJECT-TYPE
SYNTAX INTEGER {
interactive(1),
passthru(2),
passall(3),
transparent(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The default session mode when the DECServer
command interface is configured. The default
is interactive.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'default_session_mode'.
Note: This object is not valid for Synchronous ports."
::= { callGenericEntry 16 }
callGenericResolveProtocol OBJECT-TYPE
SYNTAX INTEGER {
connect(15),
telnet(17),
any(19)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default host protocol to use when starting a
dedicated port and the protocol is not
explicitly specified in the command. Is set
to one of 'telnet', connect, or any. Any
means to try LAT (connect) first and if that
fails, try telnet.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'resolve_protocol.
Note: This object is not valid for Synchronous ports."
::= { callGenericEntry 17 }
callGenericMaxSession OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of concurrent sessions allowed
on the port. A value of -1 indicates no maximum.
Setting the maximum to less than the current
number of sessions has unspecified results. This MIB
object corresponds to the NA/Admin parameter
'max_session_count'."
::= { callGenericEntry 18 }
callGenericSpeed OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum speed of the port for this call."
::= { callGenericEntry 19 }
callGenericAutoBaud OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is always set to disabled."
::= { callGenericEntry 20 }
callGenericJobs OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..1024))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Job list for this cli session."
::= { callGenericEntry 21 }
callGenericLineType OBJECT-TYPE
SYNTAX INTEGER {
cli(1),
slave(2),
unused3(3),
unused4(4),
vcli(5),
dedicated(6),
slip(7),
lpd(8),
ppp(9),
mp(10),
arap(11),
ftp(12),
unused13(13),
unused14(14),
dynamicdial(15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is what the port is running at the moment.
callgenericmode will tell you what the port is
configured to run through the spb or e2rom."
::= { callGenericEntry 22 }
-- ports flow control and signal parameters.
callSignalTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallSignalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries for port flow control and
signal parameters."
::= { connections 2 }
callSignalEntry OBJECT-TYPE
SYNTAX CallSignalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of entries of flow control and
signal parameters for active calls."
INDEX { callSignalLineIdx, callSignalIdx }
::= { callSignalTable 1 }
CallSignalEntry ::= SEQUENCE {
callSignalLineIdx INTEGER,
callSignalIdx INTEGER,
callSignalInputStartChar DisplayString,
callSignalInputStopChar DisplayString,
callSignalOutputStartChar DisplayString,
callSignalOutputStopChar DisplayString,
callSignalIxanyFlowCtrl INTEGER,
callSignalForwardKey DisplayString,
callSignalBackwardKey DisplayString,
callSignalCharInFlow INTEGER,
callSignalCharOutFlow INTEGER,
callSignalrs232AsyncBits INTEGER,
callSignalrs232AsyncStopBits INTEGER,
callSignalrs232AsyncParity INTEGER
}
callSignalLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callSignalEntry 1 }
callSignalIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callSignalEntry 2 }
-- { callSignalEntry 3 } is reserved
callSignalInputStartChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The control character sequence that restarts
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'input_start_char'.
Note: This object is not valid for
Synchronous ports."
::= { callSignalEntry 4 }
callSignalInputStopChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The control character sequence that stops
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'input_stop_char'.
Note: This object is not valid for
Synchronous ports."
::= { callSignalEntry 5 }
callSignalOutputStartChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The control character sequence that restarts
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'output_start_char'.
Note: This object is not valid for
Synchronous ports."
::= { callSignalEntry 6 }
callSignalOutputStopChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The control character sequence that stops
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'output_stop_char'.
Note: This object is not valid for
Synchronous ports."
::= { callSignalEntry 7 }
callSignalIxanyFlowCtrl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter specifies whether any input
character will be treated as a start (xon)
character when output has been suspended by
a stop (xoff) character.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ixany_flow_control'.
Note: This object is not valid for Synchronous ports."
::= { callSignalEntry 8 }
-- { callSignalEntry 9 } is reserved
callSignalForwardKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines a control character sequence as an
attention character to switch the user to
the next session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'forward_key'.
Note: This object is not valid for Synchronous ports."
::= { callSignalEntry 10 }
callSignalBackwardKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines a control character sequence as an
attention character to switch the user to
the previous session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'Backward_key'.
Note: This object is not valid for Synchronous ports."
::= { callSignalEntry 11 }
-- { callSignalEntry 12 } is reserved
-- { callSignalEntry 13 } is reserved
-- { callSignalEntry 14 } is reserved
-- { callSignalEntry 15 } is reserved
-- { callSignalEntry 16 } is reserved
callSignalCharInFlow OBJECT-TYPE
SYNTAX INTEGER {
none(1),
eia(2),
xonXoff(3),
bell(4),
both(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's type of input flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'eia'(hardware)
indicates flow control delegated to the lower level,
for example a parallel port."
::= { callSignalEntry 17 }
callSignalCharOutFlow OBJECT-TYPE
SYNTAX INTEGER {
none(1),
eia(2),
xonXoff(3),
bell(4),
both(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The port's type of output flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'eia'(hardware)
indicates flow control delegated to the lower level,
for example a parallel port."
::= { callSignalEntry 18 }
callSignalrs232AsyncBits OBJECT-TYPE
SYNTAX INTEGER (5..8)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The port's number of bits in a character. This object
corresponds to the admin parameter data_bits."
::= { callSignalEntry 19 }
callSignalrs232AsyncStopBits OBJECT-TYPE
SYNTAX INTEGER {
one(1),
one-and-half(2),
two(3),
dynamic(4)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The port's number of stop bits. This object corresponds
to the admin parameter stop_bits."
::= { callSignalEntry 20 }
callSignalrs232AsyncParity OBJECT-TYPE
SYNTAX INTEGER {
none(1),
odd(2),
even(3),
mark(4),
space(5)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The port's sense of a character parity bit."
::= { callSignalEntry 21 }
-- port login parameters.
callLoginTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallLoginEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries of login parameters for
active calls.
Note: This table is not valid for Synchronous ports."
::= { connections 3 }
callLoginEntry OBJECT-TYPE
SYNTAX CallLoginEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Call's login user parameters."
INDEX { callLoginLineIdx, callLoginIdx }
::= { callLoginTable 1 }
CallLoginEntry ::= SEQUENCE {
callLoginLineIdx INTEGER,
callLoginIdx INTEGER,
callLoginVciLoginPortPasswd INTEGER,
callLoginVciLoginTimeout INTEGER
}
callLoginLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callLoginEntry 1 }
callLoginIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callLoginEntry 2 }
callLoginVciLoginPortPasswd OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Indicates if the port is configured as a
DECServer interface port. The default is
disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'login_port_password'."
::= { callLoginEntry 3 }
callLoginVciLoginTimeout OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Enables a login timer if the port is
configured as a DECServer interface port. The
default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'login_timeout'."
::= { callLoginEntry 4 }
-- port timer and counter parameters
callTimerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallTimerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries of port timer and counter
parameters for active calls.
Note: This table is not valid for Synchronous ports."
::= { connections 4 }
callTimerEntry OBJECT-TYPE
SYNTAX CallTimerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Call's timer and counter parameters."
INDEX { callTimerLineIdx, callTimerIdx }
::= { callTimerTable 1 }
CallTimerEntry ::= SEQUENCE {
callTimerLineIdx INTEGER,
callTimerIdx INTEGER,
callTimerForwardTimer INTEGER,
callTimerForwardCount INTEGER,
callTimerCliInactivity INTEGER,
callTimerCliInactivityTimer INTEGER,
callTimerInputIsActivity INTEGER,
callTimerOutputIsActivity INTEGER,
callTimerResetIdleTimer INTEGER,
callTimerLongBreak INTEGER,
callTimerShortBreak INTEGER
}
callTimerLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callTimerEntry 1 }
callTimerIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callTimerEntry 2 }
callTimerForwardTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter defines the inter-character
timer that sets the amount of time, in tens of
milliseconds, that will elapse before
forwarding the received data. The value of
5 turns means the timer is off.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'forwarding_timer'."
::= { callTimerEntry 3 }
callTimerForwardCount OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the number of received characters
buffered for the port by the Annex before
forwarding the characters to the host or
network.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'forwarding_count'."
::= { callTimerEntry 4 }
callTimerCliInactivity OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time, in minutes, that the
Annex waits before hanging up the serial/ta
port after it becomes idle. A value of 0
indicates the timer is off. A value of 255
means immediate, which causes the Annex to
hang up the port immediately after exiting
from the last job.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'cli_inactivity'."
::= { callTimerEntry 5 }
callTimerCliInactivityTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time, in minutes, which a port
can remain inactive before the Annex
terminates all sessions and resets the port. A
value of 0 implies timer is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'inactivity_timer'."
::= { callTimerEntry 6 }
callTimerInputIsActivity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Controls whether received input characters
are considered as activity for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'input_is_activity'."
::= { callTimerEntry 7 }
callTimerOutputIsActivity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Controls whether transmitted output
characters are considered as activity for the
port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'output_is_activity'."
::= { callTimerEntry 8 }
callTimerResetIdleTimer OBJECT-TYPE
SYNTAX INTEGER {
input(1),
output(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines whether input or output resets the
idle timer for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'reset_idle_time_on'."
::= { callTimerEntry 9 }
callTimerLongBreak OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break greater than two seconds.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'long_break'."
::= { callTimerEntry 10 }
callTimerShortBreak OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break shorter than two seconds.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'short_break'."
::= { callTimerEntry 11 }
-- security parameters
callSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallSecurityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries of port security parameters
for active calls."
::= { connections 5 }
callSecurityEntry OBJECT-TYPE
SYNTAX CallSecurityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Call's security parameters."
INDEX { callSecurityLineIdx, callSecurityIdx }
::= { callSecurityTable 1 }
CallSecurityEntry ::= SEQUENCE {
callSecurityLineIdx INTEGER,
callSecurityIdx INTEGER,
callSecurityUserName DisplayString,
callSecurityCli INTEGER,
callSecurityConnect INTEGER,
callSecurityPortServer INTEGER,
callSecurityPortPasswd DisplayString,
callSecurityIpsoClass INTEGER,
callSecurityIpx INTEGER,
callSecurityCurrentUser DisplayString
}
callSecurityLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callSecurityEntry 1 }
callSecurityIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callSecurityEntry 2 }
callSecurityUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A string defining the default user name for
the user of this serial/ta port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'user_name'."
::= { callSecurityEntry 3}
callSecurityCli OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether security is
enabled for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'cli_security'."
::= { callSecurityEntry 4 }
callSecurityConnect OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether the
host-based security policy is enabled for
access from the port to the network.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'connect_security'."
::= { callSecurityEntry 5}
callSecurityPortServer OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether the
host-based security policy is enabled for
access to the port from the port server.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'port_server_security'."
::= { callSecurityEntry 6}
callSecurityPortPasswd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter defines a password for the
port for local password protection.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'port_password'."
::= { callSecurityEntry 7}
callSecurityIpsoClass OBJECT-TYPE
SYNTAX INTEGER {
none(1),
secret(2),
topsecret(3),
confidential(4),
unclassified(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the IP security classification for
packets sent and received on this port. The
default value is none.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ipso_class'."
::= { callSecurityEntry 8 }
callSecurityIpx OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Controls whether IPX security is enabled on
this port. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'ipx_security'."
::= { callSecurityEntry 9 }
callSecurityCurrentUser OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns the username for an active call on a
b channel. This MIB object is only valid if
security is enabled."
::= { callSecurityEntry 10 }
-- Line editing parameters.
callLineEditTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallLineEditEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries of line editing parameters
for active calls.
Note: This table is not valid for
synchronous ports."
::= { connections 6 }
callLineEditEntry OBJECT-TYPE
SYNTAX CallLineEditEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Call's line editing parameters."
INDEX { callLineEditLineIdx, callLineEditIdx }
::= { callLineEditTable 1 }
CallLineEditEntry ::= SEQUENCE {
callLineEditLineIdx INTEGER,
callLineEditIdx INTEGER,
callLineEditAttnChar DisplayString,
callLineEditEcho INTEGER,
callLineEditTelnetEscape DisplayString,
callLineEditTelnetCRLF INTEGER,
callLineEditMapToLower INTEGER,
callLineEditMapToUpper INTEGER,
callLineEditCharErase INTEGER,
callLineEditEraseChar DisplayString,
callLineEditLineErase INTEGER,
callLineEditEraseLine DisplayString,
callLineEditEraseWord DisplayString,
callLineEditHardwareTabs INTEGER,
callLineEditRedisplayLine DisplayString,
callLineEditToggleOutput DisplayString,
callLineEditNewLineTerm INTEGER
}
callLineEditLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callLineEditEntry 1 }
callLineEditIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callLineEditEntry 2 }
callLineEditAttnChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines a control character sequence as an
attention character to return the user to
the CLI prompt. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'attn_string'."
::= { callLineEditEntry 3 }
callLineEditEcho OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes all characters as they are received
from the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'echo'."
::= { callLineEditEntry 4 }
callLineEditTelnetEscape OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the control character that returns
the user to the 'telnet:' prompt when running
the CLI telnet command.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
The value 'U' means this feature is disabled
on this port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'telnet_escape'."
::= { callLineEditEntry 5 }
callLineEditTelnetCRLF OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines what characters are transmitted
out the port to the network when the
End-of-Line character is sensed. 'enabled'
means transmit Line-Feed and Carriage-Return.
'disabled' means transmit Carriage-Return
and NULL. The default is enabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'telnet_crlf'."
::= { callLineEditEntry 6 }
callLineEditMapToLower OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When enabled, the Annex translates all upper
case characters to lower case as they are
received from the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'map_to_lower'."
::= { callLineEditEntry 7 }
callLineEditMapToUpper OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When enabled, the Annex translates all lower
case characters to upper case as they are
transmitted to the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter '
map_to_upper'."
::= { callLineEditEntry 8 }
callLineEditCharErase OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes the character erase and word erase
characters for a video terminal (enabled)
or for a hard-copy terminal (disabled).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'char_erase'."
::= { callLineEditEntry 9 }
callLineEditEraseChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the character erase control character
sequence.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase_char'."
::= { callLineEditEntry 10 }
callLineEditLineErase OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes the line erase character for a video
terminal (enabled) or for a hard-copy terminal
(disabled).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'line_erase'."
::= { callLineEditEntry 11 }
callLineEditEraseLine OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the line erase control character
sequence.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase_line'."
::= { callLineEditEntry 12 }
callLineEditEraseWord OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the word erase control character
sequence.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase_word'."
::= { callLineEditEntry 13 }
callLineEditHardwareTabs OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When enabled, this parameter allows the Annex
to expand ASCII tab characters.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'hardware_tabs'."
::= { callLineEditEntry 14 }
callLineEditRedisplayLine OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the reprint line control character
sequence.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'redisplay_line'."
::= { callLineEditEntry 15 }
callLineEditToggleOutput OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the flush control character used to
flush the output buffer.
This value of this object can be either a
single displayable character or two characters
of the form '^x', where '^x' is translated as
'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'toggle_output'."
::= { callLineEditEntry 16 }
callLineEditNewLineTerm OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter controls whether a carriage
return is echoed as just a carriage return
(enabled), or whether the carriage return is
echoed as a carriage return and line feed.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'newline_terminal'."
::= { callLineEditEntry 17 }
-- Networking Protocol parameters.
callNetTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallNetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries of networking protocol
parameters for active calls."
::= { connections 7 }
callNetEntry OBJECT-TYPE
SYNTAX CallNetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Call's networking protocol parameters."
INDEX { callNetLineIdx, callNetIdx }
::= { callNetTable 1 }
CallNetEntry ::= SEQUENCE {
callNetLineIdx INTEGER,
callNetIdx INTEGER,
callNetLocalAddr IpAddress,
callNetRemoteAddr IpAddress,
callNetMetric INTEGER,
callNetSlipSecure INTEGER,
callNetInactivity INTEGER,
callNetDoCompression INTEGER,
callNetAllowCompression INTEGER,
callNetInactivityUnits INTEGER
}
callNetLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callNetEntry 1 }
callNetIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callNetEntry 2 }
callNetLocalAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Internet address for the Annex's side
of the point-to-point (SLIP or PPP) link.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'local_address'."
::= { callNetEntry 3 }
callNetRemoteAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Internet address for the host at the
remote end of the point-to-point (SLIP or PPP)
link.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'remote_address'."
::= { callNetEntry 4 }
-- ::= { callNetEntry 5 } removed object
callNetMetric OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter defines the hop count to
the remote end of the SLIP or PPP interface.
This MIB object corresponds to the NA/admin
asynchronous, ta. synchronous port parameter
'metric'."
::= { callNetEntry 6 }
callNetSlipSecure OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If anxEnableSecurity is disabled, this
parameter selects slip session logging. If
anxEnableSecurity is enabled, this parameter
permits slip access only from secure ports.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'slip_ppp_security'.
Note: This object is not valid for
Synchronous ports."
::= { callNetEntry 7 }
callNetInactivity OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of units allowed for serial
protocol inactivity on the port. The type of
unit, minutes or seconds, is defined by the
object anxpNetInactivityUnits. If the type of
units is 'seconds', the actual granularity is
only 5 seconds. When the interval expires,
the port is automatically reset. A value of 0
means the timer is disabled.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'net_inactivity'."
::= { callNetEntry 8 }
callNetDoCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will attempt to
negotiate TCP/IP header compression on this
serial link.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'do_compression'."
::= { callNetEntry 9 }
callNetAllowCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will allow TCP/IP
header compression on this serial link only
if the other end of the serial link initiates
the compression.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'allow_compression'."
::= { callNetEntry 10 }
callNetInactivityUnits OBJECT-TYPE
SYNTAX INTEGER {
minutes(1),
seconds(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of units that are used for the
port's net inactivity timer. See also the
anxpNetInactivity object. The default value
is 'minutes'.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'net_inactivity_units'."
::= { callNetEntry 11 }
-- Slip parameters.
callSlipTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallSlipEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries of Slip parameters for
active calls.
Note: This object is not valid for
Synchronous ports."
::= { connections 8 }
callSlipEntry OBJECT-TYPE
SYNTAX CallSlipEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Call's Slip parameters."
INDEX { callSlipIdx }
::= { callSlipTable 1 }
CallSlipEntry ::= SEQUENCE {
callSlipLineIdx INTEGER,
callSlipIdx INTEGER,
callSlipSubnetMask IpAddress,
callSlipMtuSize INTEGER,
callSlipNoIcmp INTEGER,
callSlipTos INTEGER
}
callSlipLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callSlipEntry 1 }
callSlipIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callSlipEntry 2 }
callSlipSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The subnet mask for this SLIP interface.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'subnet_mask'."
::= { callSlipEntry 3 }
callSlipMtuSize OBJECT-TYPE
SYNTAX INTEGER {
large(1),
small(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Force the compressed SLIP interface to use
a Maximum Transmission Unit (MTU) of either
1024 bytes (large) or 256 bytes (small). The
default is large.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'slip_mtu_size'."
::= { callSlipEntry 4 }
callSlipNoIcmp OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will discard any
ICMP packets directed to this SLIP link.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'slip_no_icmp'."
::= { callSlipEntry 5 }
callSlipTos OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When enabled, the Annex sends interactive
traffic over this SLIP link before any other
traffic.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'slip_tos'."
::= { callSlipEntry 6 }
-- PPP parameters
callPPPTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallPPPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of entries of PPP parameters for
active calls."
::= { connections 9 }
callPPPEntry OBJECT-TYPE
SYNTAX CallPPPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Call's PPP parameters."
INDEX { callPPPLineIdx, callPPPIdx }
::= { callPPPTable 1 }
CallPPPEntry ::= SEQUENCE {
callPPPLineIdx INTEGER,
callPPPIdx INTEGER,
callPPPMru INTEGER,
callPPPAcm DisplayString,
callPPPSecurityProto INTEGER,
callPPPRemoteUser DisplayString,
callPPPRemotePasswd DisplayString,
callPPPNcp INTEGER,
callPPPIpxNetwork DisplayString,
callPPPIpxNode DisplayString,
callPPPTraceLevel INTEGER
}
callPPPLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callPPPEntry 1 }
callPPPIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callPPPEntry 2 }
callPPPMru OBJECT-TYPE
SYNTAX INTEGER (64..1500)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter defines the maximum receive
unit in bytes. The default value is 1500.
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter 'ppp_mru'."
::= { callPPPEntry 3 }
callPPPAcm OBJECT-TYPE
SYNTAX DisplayString (SIZE (8..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter specifies which of the first
32 bytes (0x00, ... 0x1F) can be sent as
clear text and which need to be escaped. A
bit on in the mask indicates the character
must be escaped. The mask should be specified
as an 8 hex character string (0x1F000000 and
1F000000 are both acceptable).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ppp_acm'."
::= { callPPPEntry 4 }
callPPPSecurityProto OBJECT-TYPE
SYNTAX INTEGER {
none(1),
pap(2),
chap(3),
chap-pap(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines which security protocol will be used
to authenticate the remote user. This
parameter must be set and the Annex
enable_security (anxEnableSecurity) must be
enabled before authentication is performed.
The default is none
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'ppp_security_protocol'."
::= { callPPPEntry 5 }
callPPPRemoteUser OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The username used by the Annex to identify
itself if the remote PPP peer asks for
authentication.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'ppp_username_remote'."
::= { callPPPEntry 6 }
callPPPRemotePasswd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The password used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the password is
defined or <unset> if the password is not
defined.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'ppp_password_remote'."
::= { callPPPEntry 7 }
callPPPNcp OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bitmask for PPP NCP Options:
0x0002 NCP_IPCP
0x0004 NCP_ATCP
0x0008 NCP_IPXCP
0x0010 NCP_MP
0x0020 NCP_CCP
0x0040 NCP_CBCP
Note: if the ncp_option parameter
is set to the value of 'all', the SNMP
agent will return the fully expanded bitmask
value instead of the 0x0001 value of 'all'.
"
::= { callPPPEntry 8 }
callPPPIpxNetwork OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPX network number for an IPX PPP
connection using this port. When the IPX PPP
connection is established the network number
will be negotiated. If one end of the
connection is set to zero then the value from
the other end of the connection will be used.
The value of this object is an 8 digit
hexadecimal number string representing the
IPX network segment assigned to this port.
The value must be unique across the network
domain.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'ppp_ipx_network'."
::= { callPPPEntry 9 }
callPPPIpxNode OBJECT-TYPE
SYNTAX DisplayString (SIZE(11..17))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPX node number for an IPX PPP connection
using this port.
The value of this object is a 12 digit
hexadecimal number string representing the IPX
node number assigned to this port.
Note the string is expected in the form:
12-3a-4-7-89-23.Each part of the address
must be a hex value separated by a hyphen.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'ppp_ipx_node'."
::= { callPPPEntry 10 }
callPPPTraceLevel OBJECT-TYPE
SYNTAX INTEGER {
control(1),
data(2),
control-and-data(3),
unused(4),
control-in-hex(5),
data-in-hex(6),
control-and-data-in-hex(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Controls whether PPP trace messages are sent to the
syslog facility or not. The default value is none(0).
This MIB object corresponds to the na/admin port parameter
ppp_trace_level."
::= { callPPPEntry 11 }
-- ARAP parameters
callARAPTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallARAPEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of entries of Apple Talk parameters for
active calls.
Note: This object is not valid for
Synchronous ports."
::= { connections 10 }
callARAPEntry OBJECT-TYPE
SYNTAX CallARAPEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Call's ARAP parameters."
INDEX {callARAPLineIdx, callARAPIdx }
::= { callARAPTable 1 }
CallARAPEntry ::= SEQUENCE {
callARAPLineIdx INTEGER,
callARAPIdx INTEGER,
callARAPGuest INTEGER,
callARAPNodeId DisplayString,
callARAPSecurity INTEGER,
callARAPV42BIS INTEGER
}
callARAPLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS deprecated
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callARAPEntry 1 }
callARAPIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callARAPEntry 2 }
callARAPGuest OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"If enabled, allows ARAP guest login service.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at_guest'."
::= { callARAPEntry 3 }
callARAPNodeId OBJECT-TYPE
SYNTAX DisplayString (SIZE (3..11))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The default AppleTalk node ID hint that is
used by the Annex on this port. The address
consists of two parts separated by a dot. The
address may be in either hex or decimal
format. The first part is the network address
and ranges from 0 to 65534 (0x0000 to 0xFFFE).
The second part is the node address and ranges
from 0 to 254 (0x00 to 0xFE).
Example:
0x00BF.0xFD 191.253 0x00BF.253 191.0xFD
are all the same address.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at_nodeid'."
::= { callARAPEntry 4 }
callARAPSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Controls whether ACP service is enabled for
this port when establishing an AppleTalk
connection.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at_security'."
::= { callARAPEntry 5 }
callARAPV42BIS OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Controls whether V.42bis compression is done
during an ARAP session.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'arap_v42bis'."
::= { callARAPEntry 6 }
-- TN3270 parameters
callTN3270Table OBJECT-TYPE
SYNTAX SEQUENCE OF CallTN3270Entry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of entries of TN3270 parameters for
active calls.
Note:This object is not valid for
Synchronous ports."
::= { connections 11 }
callTN3270Entry OBJECT-TYPE
SYNTAX CallTN3270Entry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Call's TN3270 parameters."
INDEX { callTN3270LineIdx, callTN3270Idx }
::= { callTN3270Table 1 }
CallTN3270Entry ::= SEQUENCE {
callTN3270LineIdx INTEGER,
callTN3270Idx INTEGER,
callTN3270PrinterHost IpAddress,
callTN3270PrinterName DisplayString
}
callTN3270LineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS deprecated
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callTN3270Entry 1 }
callTN3270Idx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callTN3270Entry 2 }
callTN3270PrinterHost OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The IP address of the machine running a
Berkeley-style lpd server.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'tn3270_printer_name'."
::= { callTN3270Entry 3 }
callTN3270PrinterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A valid printer name contained in the
/etc/printcap file on the remote host.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'tn3270_printer_name'."
::= { callTN3270Entry 4 }
-- Port LAT parameters
callLATTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallLATEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of entries of LAT parameters for
active calls.
Note:This object is not valid for
synchronous ports."
::= { connections 12 }
callLATEntry OBJECT-TYPE
SYNTAX CallLATEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Call's LAT parameters."
INDEX { callLATLineIdx, callLATIdx }
::= { callLATTable 1 }
CallLATEntry ::= SEQUENCE {
callLATLineIdx INTEGER,
callLATIdx INTEGER,
callLATAuthMap OCTET STRING,
callLATbEnable INTEGER,
callLATMultiSession INTEGER
}
callLATLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS deprecated
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callLATEntry 1 }
callLATIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callLATEntry 2 }
callLATAuthMap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..32))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The syntax of this object is an octet string
32 bytes long, with the first byte
representing groups 0 through 7 and the last
byte representing groups 248 through 255.
For example, 0x40 0x25 ... means the groups
1,10,13,15 are valid for this port.
A returned value with all bits set to zero is
the same as setting 'group_value' to 'none'.
The object always returns a string 32 bytes
long.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'group_value'."
::= { callLATEntry 3 }
callLATbEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Controls interpretation of LAT Data-B packets
received from host.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'latb_enable'."
::= { callLATEntry 4 }
callLATMultiSession OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This parameter allows multisession operation
to be managed on a per port basis. If
multisessions for the server has not been
enabled, any attempt to use this command will
cause the error message
'ETSMIN-786-Multisession feature Disabled'
to be displayed.
This MIB object corresponds to the NA/admin
port parameter 'multisessions'.
Note:
* SNMP will not check for the Annex
MultiSession parameter.
* Setting this MIB object is equivalent to
defining the port parameter 'multisession'
through NA/admin."
::= { callLATEntry 5 }
-- Call SETUP information parameters
callSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF CallSetupEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of entries of call setup information
active calls."
::= { connections 13 }
callSetupEntry OBJECT-TYPE
SYNTAX CallSetupEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Call's Setup information parameters."
INDEX { callSetupLineIdx, callSetupIdx }
::= { callSetupTable 1 }
CallSetupEntry ::= SEQUENCE {
callSetupLineIdx INTEGER,
callSetupIdx INTEGER,
callSetupPortType INTEGER,
callSetupCallType INTEGER,
callSetupCallingTime INTEGER,
callSetupCallingNbr DisplayString,
callSetupCalledNbr DisplayString,
callSetupCalledSubAddr DisplayString,
callSetupBearer INTEGER,
callSetupPortNumber INTEGER
}
callSetupLineIdx OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS deprecated
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213).
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { callSetupEntry 1 }
callSetupIdx OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A call's B channel number ranging from 1-30."
::= { callSetupEntry 2 }
callSetupPortType OBJECT-TYPE
SYNTAX INTEGER {
async(1),
sync(2),
ta(3),
detecting(4)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A enumerated integer indicating the port
type. Detecting(4) means the annex is in the
process of detecting the port type."
::= { callSetupEntry 3 }
callSetupCallType OBJECT-TYPE
SYNTAX INTEGER {
incoming(1),
outgoing(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object returns the whether the call is
incoming or outgoing."
::= { callSetupEntry 4 }
callSetupCallingTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object returns the time the call has been
in progress. Measured in seconds"
::= { callSetupEntry 5 }
callSetupCallingNbr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object returns the calling number."
::= { callSetupEntry 6 }
callSetupCalledNbr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object returns the number called."
::= { callSetupEntry 7 }
callSetupCalledSubAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object returns called party subaddress."
::= { callSetupEntry 8 }
callSetupBearer OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object defines the bearer capability
of the incoing call. Possible values are
voice and data."
::= { callSetupEntry 9 }
callSetupPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object returns the port number the call
is assigned to. This object in conjunction with the
object, port type, should be used to cross-reference
the information displayed by the CLI command 'who'."
::= { callSetupEntry 10 }
-- PRI Global parameters.
gpGenericMode OBJECT-TYPE
SYNTAX INTEGER {
cli(1),
slave(2),
adaptive(3),
unused(4),
slip(5),
ppp(7),
auto-detect(10),
auto-adapt(11),
rlogin(16),
telnet(17)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the mode for access
to the serial line or TA port.
The default is cli.
This MIB object corresponds to the NA/admin
asynchronous,ta, synchronous port parameter
'mode'.
Note: Values 6, 8, 9, 12, 13, 14, 15, and 18
cannot be set."
::= { globals 1 }
gpGenericLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A descriptive string for a this port. This
string is displayed by the CLI who command.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'location'."
::= { globals 2 }
gpGenericTermVar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string defining the type of terminal
attached to the serial/ta port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'term_var'.
Note: This object is not valid for
synchronous ports."
::= { globals 3 }
gpGenericPrompt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines a port-specific prompt
string. The prompt string consists of displayable
characters and embedded formatting codes. Each
formatting code is stored in a single character
in nonvolatile memory. The maximum number of
characters stored for the prompt string
is 16. Since the formatting codes consist of
a '%' prepended to a single character, the maximum
length string that may be entered for this object
is 32 characters. Strings less than 32
characters in length will be rejected as bad values
if they cannot be stored into 16 characters in
nonvolatile memory after the formatting codes are
compressed into single characters.
The valid formatting codes are:
%a the string 'annex'
%c the string ': '
%d the date and time
%i the Annex's IP address
%j a newline character
%l port location, or 'port n'
%n the Annex's name
%p the port number
%r the string 'port'
%s a space
%t the time hh:mm:ss
%u the user name for port
%% the string '%'
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'prompt'.
Note: This object is not valid for
synchronous ports."
::= { globals 4 }
gpGenericCliInterface OBJECT-TYPE
SYNTAX INTEGER {
uci(1),
vci(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Specifies either a Unix or VMS command line
interface. The default is uci.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'cli_interface'.
Note: This object is not valid for
synchronous ports."
::= { globals 5 }
gpGenericAllowBcast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether the serial/ta port can
receive administrative broadcast messages.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter
'allow_broadcast'.
Note: This object is not valid for
synchronous ports."
::= { globals 6 }
gpGenericBcastDirection OBJECT-TYPE
SYNTAX INTEGER {
port(1),
network(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the direction that an administrative
broadcast message is sent. This parameter is
valid only when the port is defined as a slave
port by the anxpMode parameter.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'broadcast_direction'.
Note: This object is not valid for Synchronous ports."
::= { globals 7 }
gpGenericImask7Bits OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, instructs the Annex to ignore
the eighth bit of all received characters
on the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'imask_7bits'.
Note: This object is not valid for Synchronous ports."
::= { globals 8 }
gpGenericCliImask7 OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines whether input at the CLI is masked to
7 bits. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'cli_imask7'. The
default value for this object is enabled.
Note: This object is not valid for Synchronous ports."
::= { globals 9 }
gpGenericBanner OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
beforesec(3),
aftersec(4),
motd-before-sec(5),
motd-after-sec(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether the Annex banner and message-
of-the-day are displayed on the port. The
default is enabled.
This has four possible actions:
default, Y, yes, unset: banner before security,
motd after
none, N: no banner or motd
beforesec: banner and motd before
security
aftersec: banner and motd after
security
motd-before-sec: motd before security; no
banner
motd-after-sec: motd after security; no
banner
This MIB object corresponds to the NA/admin
asynchronous port parameter 'banner'.
Note: This object is not valid for Synchronous ports."
::= { globals 10 }
gpGenericTcpKeepAlive OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The default keep-alive value for connections
to this serial port. If this is zero, use the
value specified by anxTcpKeepAlive.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'tcp_keepalive'.
Note: This object is not valid for Synchronous ports."
::= { globals 11 }
gpGenericDedicatedArgs OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command line arguments to be passed to process
started by a dedicated port with mode set to
'telnet', 'tn3270', 'rlogin', 'connect' (if LAT
is in use) or 'call'.
This object is not valid for TA ports.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'dedicated_arguments'.
Note: This object is not valid for Synchronous ports."
::= { globals 12 }
gpGenericModemVar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string defining the type of modem attached
to the serial port.
This object is not valid for TA ports.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'type_of_modem'.
Note: This object is not valid for Synchronous ports."
::= { globals 13 }
gpGenericDefSessMode OBJECT-TYPE
SYNTAX INTEGER {
interactive(1),
passthru(2),
passall(3),
transparent(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The default session mode when the DECServer command
interface is configured. The default is interactive.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'default_session_mode'.
Note: This object is not valid for Synchronous ports."
::= { globals 14 }
gpGenericResolveProtocol OBJECT-TYPE
SYNTAX INTEGER {
connect(15),
telnet(17),
any(19)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Default host protocol to use when starting a
dedicated port and the protocol is not explicitly
specified in the command. Is set to one of
'telnet', connect, or any. Any means to try LAT
(connect) first and if that fails, try telnet.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'resolve_protocol.
Note: This object is not valid for Synchronous ports."
::= { globals 15 }
-- ports flow control and signal parameters.
-- { globals 16 } is reserved
gpSignalInputStartChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control character sequence that restarts
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'input_start_char'.
Note: This object is not valid for
synchronous ports."
::= { globals 17 }
gpSignalInputStopChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control character sequence that stops
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'input_stop_char'.
Note: This object is not valid for
synchronous ports."
::= { globals 18 }
gpSignalOutputStartChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control character sequence that restarts
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'output_start_char'.
Note: This object is not valid for
synchronous ports."
::= { globals 19 }
gpSignalOutputStopChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control character sequence that stops
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'output_stop_char'.
Note: This object is not valid for
synchronous ports."
::= { globals 20 }
gpSignalIxanyFlowCtrl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter specifies whether any input
character will be treated as a start (xon)
character when output has been suspended by
a stop (xoff) character.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ixany_flow_control'.
Note: This object is not valid for
synchronous ports."
::= { globals 21 }
-- { globals 22 } is reserved
gpSignalForwardKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines a control character sequence as an
attention character to switch the user to
the next session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'forward_key'.
Note: This object is not valid for
synchronous ports."
::= { globals 23 }
gpSignalBackwardKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines a control character sequence as an
attention character to switch the user to
the previous session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'Backward_key'.
Note: This object is not valid for Synchronous ports."
::= { globals 24 }
-- { globals 25 } is reserved
-- { globals 26 } is reserved
-- { globals 27 } is reserved
-- { globals 28 } is reserved
-- { globals 29 } is reserved
-- port login parameters.
gpLoginVciLoginPortPasswd OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Enables the port password if the port is
configured as a DECServer interface port.
The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'login_port_password'."
::= { globals 30 }
gpLoginVciLoginTimeout OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Enables a login timer if the port is configured
as a DECServer interface port. The default
is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'login_timeout'."
::= { globals 31 }
-- port timer and counter parameters
gpTimerForwardTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the inter-character
timer that sets the amount of time, in tens of
milliseconds, that will elapse before
forwarding the received data. The value of
5 turns off the timer. Setting this object
to 0 causes the default value of 5 to be used.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'forwarding_timer'."
::= { globals 32 }
gpTimerForwardCount OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the number of received characters
buffered for the port by the Annex before
forwarding the characters to the host or
network.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'forwarding_count'."
::= { globals 33 }
gpTimerCliInactivity OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time, in minutes, that the Annex
waits before hanging up the serial/ta port after
it becomes idle. A value of 0 turns off the
timer. A value of 255 means immediate, which
causes the Annex to hang up the port immediately
after exiting from the last job.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'cli_inactivity'."
::= { globals 34 }
gpTimerInactivityTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time, in minutes, which a port
can remain inactive before the Annex terminates
all sessions and resets the port. A value of
0 disables the timer.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'inactivity_timer'."
::= { globals 35 }
gpTimerInputIsActivity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether received input characters
are considered as activity for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'input_is_activity'."
::= { globals 36 }
gpTimerOutputIsActivity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether transmitted output characters
are considered as activity for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'output_is_activity'."
::= { globals 37 }
gpTimerResetIdleTimer OBJECT-TYPE
SYNTAX INTEGER {
input(1),
output(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines whether input or output resets the
idle timer for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'reset_idle_time_on'."
::= { globals 38 }
gpTimerLongBreak OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break greater than two seconds.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'long_break'."
::= { globals 39 }
gpTimerShortBreak OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break shorter than two seconds.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'short_break'."
::= { globals 40 }
-- security parameters
gpSecurityUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string defining the default user name for
the user of this serial/ta port.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'user_name'."
::= { globals 41 }
gpSecurityCli OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether security is
enabled for the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'cli_security'."
::= { globals 42 }
gpSecurityConnect OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the host-based
security policy is enabled for access from the
port to the network.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'connect_security'."
::= { globals 43 }
gpSecurityPortServer OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the host-based
security policy is enabled for access to the
port from the port server.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'port_server_security'."
::= { globals 44 }
gpSecurityPortPasswd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines a password for the
port for local password protection.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'port_password'."
::= { globals 45 }
gpSecurityIpsoClass OBJECT-TYPE
SYNTAX INTEGER {
none(1),
secret(2),
topsecret(3),
confidential(4),
unclassified(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the IP security classification for
packets sent and received on this port. The
default value is none.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ipso_class'."
::= { globals 46 }
gpSecurityIpx OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether IPX security is enabled on
this port. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'ipx_security'."
::= { globals 47 }
-- Line editing parameters.
gpLineEditAttnChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines a control character sequence as an
attention character to return the user to
the CLI prompt. The Annex-II only allows
x a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'attn_string'."
::= { globals 48 }
gpLineEditEcho OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes all characters as they are received
from the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'echo'."
::= { globals 49 }
gpLineEditTelnetEscape OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the control character that returns the
user to the 'telnet:' prompt when running the
CLI telnet command.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
The value 'U' disables this feature on the
specified port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'telnet_escape'."
::= { globals 50 }
gpLineEditTelnetCRLF OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines what characters are transmitted
out the port to the network when the
End-of-Line character is sensed. 'enabled'
means transmit Line-Feed and Carriage-Return.
'disabled' means transmit Carriage-Return
and NULL. The default is enabled.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'telnet_crlf'."
::= { globals 51 }
gpLineEditMapToLower OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex translates all upper
case characters to lower case as they are
received from the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'map_to_lower'."
::= { globals 52 }
gpLineEditMapToUpper OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex translates all lower
case characters to upper case as they are
transmitted to the port.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'map_to_upper'."
::= { globals 53 }
gpLineEditCharErase OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes the character erase and word erase
characters for a video terminal (enabled)
or for a hard-copy terminal (disabled).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'char_erase'."
::= { globals 54 }
gpLineEditEraseChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the character erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase_char'."
::= { globals 55 }
gpLineEditLineErase OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes the line erase character for a video
terminal (enabled) or for a hard-copy terminal
(disabled).
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'line_erase'."
::= { globals 56 }
gpLineEditEraseLine OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the line erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase_line'."
::= { globals 57 }
gpLineEditEraseWord OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the word erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'erase_word'."
::= { globals 58 }
gpLineEditHardwareTabs OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, this parameter allows the Annex
to expand ASCII tab characters.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'hardware_tabs'."
::= { globals 59 }
gpLineEditRedisplayLine OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the reprint line control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'redisplay_line'."
::= { globals 60 }
gpLineEditToggleOutput OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the flush control character used to
flush the output buffer.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'toggle_output'."
::= { globals 61 }
gpLineEditNewLineTerm OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether a carriage
return is echoed as just a carriage return
(enabled), or whether the carriage return is
echoed as a carriage return and line feed.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'newline_terminal'."
::= { globals 62 }
-- Networking Protocol parameters.
gpNetLocalAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address for the Annex's side
of the point-to-point (SLIP or PPP) link.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'local_address'."
::= { globals 63 }
gpNetRemoteAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Internet address for the host at the
remote end of the point-to-point (SLIP or PPP)
link.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'remote_address'."
::= { globals 64 }
gpNetPppDialupAddr OBJECT-TYPE
SYNTAX INTEGER {
local(1),
authserver(2),
dhcp(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"
local(1) - The annex will get the
PPP dialup addresses from the port
parameters local_address and remote_address.
acp(2) - The Annex requests the
PPP dialup addresses from the host-based
ACP.
dhcp(3) - The Annex requests the
PPP dialup addresses from the host-based
DHCP.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous global port
parameter 'address_origin'."
::= { globals 65 }
gpNetMetric OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the hop count to
the remote end of the SLIP or PPP interface.
Setting this object to 0 defaults to a
value of 1.
This MIB object corresponds to the NA/admin
asynchronous, ta. synchronous port parameter
'metric'."
::= { globals 66 }
gpNetSlipSecure OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If anxEnableSecurity is not set, this
parameter selects slip session logging. If
anxEnableSecurity is set, this parameter
permits slip access only from secure ports.
This MIB object corresponds to the NA/admin
asynchronous, ta and sync port parameter 'slip_ppp_security'."
::= { globals 67 }
gpNetInactivity OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of units allowed for serial protocol
inactivity on the port. The type of unit, minutes
or seconds, is defined by the object
anxpNetInactivityUnits. If the type of units is
'seconds', the actual granularity is only 5
seconds. When the interval expires,
the port is automatically reset. A value of 0
disables the timer.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'net_inactivity'."
::= { globals 68 }
gpNetDoCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will attempt to negotiate
TCP/IP header compression on this serial link.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter
'do_compression'."
::= { globals 69 }
gpNetAllowCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will allow TCP/IP
header compression on this serial link only
if the other end of the serial link initiates
the compression.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'allow_compression'."
::= { globals 70 }
gpNetInactivityUnits OBJECT-TYPE
SYNTAX INTEGER {
minutes(1),
seconds(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of units that are used for the
port's net inactivity timer. See also the
anxpNetInactivity object. The default value
is 'minutes'.
This MIB object corresponds to the NA/admin
asynchronous, ta, synchronous port parameter
'net_inactivity_units'."
::= { globals 71 }
-- Slip parameters.
gpSlipSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The subnet mask for this SLIP interface.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'subnet_mask'."
::= { globals 72 }
gpSlipMtuSize OBJECT-TYPE
SYNTAX INTEGER {
large(1),
small(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force the compressed SLIP interface to use
a Maximum Transmission Unit (MTU) of either
1024 bytes (large) or 256 bytes (small). The
default is large.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'slip_mtu_size'."
::= { globals 73 }
gpSlipNoIcmp OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will discard any
ICMP packets directed to this SLIP link.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'slip_no_icmp'."
::= { globals 74 }
gpSlipTos OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex sends interactive
traffic over this SLIP link before any other
traffic.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'slip_tos'."
::= { globals 75 }
-- PPP parameters
gpPPPMru OBJECT-TYPE
SYNTAX INTEGER (64..1500)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the maximum receive
unit in bytes. The default value is 1500.
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter 'ppp_mru'."
::= { globals 76 }
gpPPPAcm OBJECT-TYPE
SYNTAX DisplayString (SIZE (8..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter specifies which of the first
32 bytes (0x00, ... 0x1F) can be sent as
clear text and which need to be escaped. A
bit on in the mask indicates the character
must be escaped. The mask should be specified
as an 8 hex character string (0x1F000000 and
1F000000 are both acceptable).
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp_acm'."
::= { globals 77 }
gpPPPSecurityProto OBJECT-TYPE
SYNTAX INTEGER {
none(1),
pap(2),
chap(3),
chap-pap(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines which security protocol will be used
to authenticate the remote user. This
parameter must be set and the Annex
enable_security (anxEnableSecurity) must be
enabled before authentication is performed.
The default is none
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp_security_protocol'."
::= { globals 78 }
gpPPPRemoteUser OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The username used by the Annex to identify
itself if the remote PPP peer asks for
authentication.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp_username_remote'."
::= { globals 79 }
gpPPPRemotePasswd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The password used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the password is
defined or <unset> if the password is not
defined.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp_password_remote'."
::= { globals 80 }
gpPPPNcp OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A bitmask to set the PPP NCP Options:
0x0001 NCP_ALL
0x0002 NCP_IPCP
0x0004 NCP_ATCP
0x0008 NCP_IPXCP
0x0010 NCP_MP
0x0020 NCP_CCP
0x0040 NCP_CBCP
"
::= { globals 81 }
gpPPPIpxNetwork OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IPX network number for an IPX PPP connection
using this port. When the IPX PPP connection is
established the network number will be negotiated.
If one end of the connection is set to zero then
the value from the other end of the connection will
be used.
The value of this object is an 8 digit hexadecimal
number string representing the IPX network segment
assigned to this port. The value must be unique
across the network domain.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp_ipx_network'."
::= { globals 82 }
gpPPPIpxNode OBJECT-TYPE
SYNTAX DisplayString (SIZE(11..17))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IPX node number for an IPX PPP connection
using this port.
The value of this object is a 12 digit
hexadecimal number string representing the IPX
node number assigned to this port.
Note the string is expected in the form:
12-3a-4-7-89-23.Each part of the address
must be a hex value separated by a hyphen.
This MIB object corresponds to the NA/admin
asynchronous/ta/sync port parameter 'ppp_ipx_node'."
::= { globals 83 }
-- ARAP parameters
gpARAPGuest OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"If enabled, allows ARAP guest login service.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at_guest'."
::= { globals 84 }
gpARAPNodeid OBJECT-TYPE
SYNTAX DisplayString (SIZE (3..11))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The default AppleTalk node ID hint that is
used by the Annex on this port. The address
consists of two parts separated by a dot. The
address may be in either hex or decimal format.
The first part is the network address and ranges from
0 to 65534 (0x0000 to 0xFFFE). The second part
is the node address and ranges from 0 to 254 (0x00
to 0xFE).
Example:
0x00BF.0xFD 191.253 0x00BF.253 191.0xFD
are all the same address.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at_nodeid'."
::= { globals 85 }
gpARAPSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls whether ACP service is enabled for
this port when establishing an AppleTalk
connection.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'at_security'."
::= { globals 86 }
gpARAPV42BIS OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls whether V.42bis compression is done
during an ARAP session.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'arap_v42bis'."
::= { globals 87 }
-- TN3270 parameters
gpTN3270PrinterHost OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The IP address of the machine running a
Berkeley-style lpd server.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'tn3270_printer_name'."
::= { globals 88 }
gpTN3270PrinterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A valid printer name contained in the
/etc/printcap file on the remote host.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'tn3270_printer_name'."
::= { globals 89 }
-- Port LAT parameters
gpLATAuthMap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This port parameter is functionally identical to
anxpLatAuthGroupVal and corresponds to the
NA/admin Annex parameter 'group_value'.
The syntax of this object is an octet string
32 bytes long, with the first byte
representing groups 0 through 7 and the last
byte representing groups 248 through 255.
For example, 0x40 0x25 ... means the groups
1,10,13,15 are valid for this port.
A returned value with all bits set to zero is the
same as setting 'group_value' to 'none'.
The object always returns a string 32 bytes long.
Note: You may use either this object or
anxpLatAuthVal object to read or set the
'group_value' parameter.anxpLatAuthMap is
preferred."
::= { globals 90 }
gpLATbEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls interpretation of LAT Data-B packets
received from host.
This MIB object corresponds to the NA/admin
asynchronous/ta port parameter 'latb_enable'."
::= { globals 91 }
gpLATMultiSession OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter allows multisession operation to
be managed on a per port basis. If multisessions
for the server has not been enabled, any attempt
to use this command will cause the error message
'ETSMIN-786-Multisession feature Disabled' to be
displayed.
This MIB object corresponds to the NA/admin port
parameter 'multisessions'.
Note: * SNMP will not check for the Annex
MultiSession parameter.
* Setting this MIB object is equivalent to
defining the port parameter 'multisession'
through NA/admin."
::= { globals 92 }
-- parameters from character MIB RFC1316
gpcharPortInFlowType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
xonXoff(2),
hardware(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port's type of input flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'hardware'
indicates flow control delegated to the lower level,
for example a parallel port.
'ctsRts' and 'dsrDtr' are specific to RS-232-like
ports. Although not architecturally pure, they are
included here for simplicity's sake.
Default is eia or hardware(3)."
::= { globals 94 }
gpcharPortOutFlowType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
xonXoff(2),
hardware(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port's type of output flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'hardware'
indicates flow control delegated to the lower level,
for example a parallel port.
'ctsRts' and 'dsrDtr' are specific to RS-232-like
ports. Although not architecturally pure, they are
included here for simplicy's sake.
Default is eia or hardware(3)."
::= { globals 95 }
gpcharPortSessionMaximum OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum number of concurrent sessions allowed
on the port. A value of -1 indicates no maximum.
Setting the maximum to less than the current
number of sessions has unspecified results.
Default is 3. This MIB object corresponds to NA/Admin
parameter 'max_session_count'."
::= { globals 96 }
-- MIB objects from rs232 MIB RFC1317
gprs232AsyncPortBits OBJECT-TYPE
SYNTAX INTEGER (5..8)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The port's number of bits in a character. This object
corresponds to the admin parameter data_bits"
::= { globals 97 }
gprs232AsyncPortStopBits OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
one-and-half(3)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The port's number of stop bits. This object corresponds
to the admin parameter stop_bits"
::= { globals 98 }
gprs232AsyncPortParity OBJECT-TYPE
SYNTAX INTEGER {
none(1),
odd(2),
even(3)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The port's sense of a character parity bit."
::= { globals 99 }
gpV120Mru OBJECT-TYPE
SYNTAX INTEGER (30..260)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the maximum receive
unit in bytes. The default value is 256.
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter 'v120_mru'."
::= { globals 101 }
gpMpMrru OBJECT-TYPE
SYNTAX INTEGER (64..1600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter sets the upper limit of
the MRRU LCP negotiation. All LCP
negotiations will start with this value;
negotiation downward only is allowed.
The default value is 1500.
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter `mp_mrru'."
::= { globals 102 }
gpMpEndPointClass OBJECT-TYPE
SYNTAX INTEGER {
nullclass(1),
local(2),
unitipaddr(3),
unitmacaddr(4),
psnDirNbr(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter sets the preference for the
Endpoint Discriminator. PPP Magic Number
Block(5) isexcluded; it doesn't guarantee
unique link identities and could lead to
illegal bundle memebership.
The default is unitmacaddr(4).
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter `mp_endpoint_option'."
::= { globals 103}
gpMpEndPointValue OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter sets the value of the
Endpoint Discriminator for options that
require user-configured information.
This parameter is only valid when
gpMPEndPointClass is set to Public Switched
Network Directory Number E.164 (6).
This MIB object corresponds to the NA/admin
asynchronous, ta, and synchronous port
parameter `mp_endpoint_address'."
::= { globals 104}
gpProxyArpEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether the Annex will proxy
ARP all remote IP connections. A value
of enabled(1) will allow the Annex to proxy
all remote IP connections. A value of
disabled(2) allows the Annex to proxy only
remote IP connections having the same
subnet address as the Annex.
This MIB object corresponds to the
NA/admin global port parameter
'proxy_arp_enabled'."
::= { globals 105}
gpPPPTraceLevel OBJECT-TYPE
SYNTAX INTEGER {
control(1),
data(2),
control-and-data(3),
unused(4),
control-in-hex(5),
data-in-hex(6),
control-and-data-in-hex(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether PPP trace messages are sent to the
syslog facility or not. The default value is none(0).
This MIB object corresponds to the na/admin port parameter
ppp_trace_level."
::= { globals 106 }
-- anxtunnelport for UDAS
anxTunnelTable OBJECT-TYPE
SYNTAX SEQUENCE OF AnxTunnelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of tunnel entries."
::= { anxtunnelport 1 }
anxTunnelEntry OBJECT-TYPE
SYNTAX AnxTunnelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A UDAS Tunnel entry."
INDEX { anxTunnelLineIndex, anxTunnelUnitIndex }
::= { anxTunnelTable 1 }
AnxTunnelEntry ::= SEQUENCE {
anxTunnelLineIndex INTEGER,
anxTunnelUnitIndex INTEGER,
anxTunnelWanProtocol INTEGER,
anxTunnelWanAddress OCTET STRING,
anxTunnelState INTEGER,
anxTunnelMnIPAddress IpAddress,
anxTunnelMnIPXAddress DisplayString,
anxTunnelHaAddress IpAddress
}
anxTunnelLineIndex OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h) -- Change `7fffffff'h to
ACCESS read-only -- 2147483647 for mib2schema
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
The interface identified by a particular value
of this index is the same interface as identified
by the same value of ifIndex from the Interfaces
table of MIB-II (RFC 1213). This is unused for
the ra2000, ra4000 platforms but needs to be
filled in with a 1.
Look at anxt1WanModuleTable for an alternative way
of getting the interface number for a physical WAN
module"
::= { anxTunnelEntry 1 }
anxTunnelUnitIndex OBJECT-TYPE
SYNTAX INTEGER (1..3000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"On a PRI interface, this is a call's B channel number ranging
from 1 to anxt1TotChan. On a port interface, this
is the port number ranging from 1 to ports.totalports."
::= { anxTunnelEntry 2 }
anxTunnelWanProtocol OBJECT-TYPE
SYNTAX INTEGER {
serial-line(1),
ppp(2),
framerelay(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field describes the protocol used
on the WAN interface from the Gateway
(or Home Agent) to the customer premise
equipment (CPE)."
::= { anxTunnelEntry 3 }
anxTunnelWanAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field describes the WAN Address from the
Gateway (or Home Agent) to the customer
premise equipment (CPE)."
::= { anxTunnelEntry 4 }
anxTunnelState OBJECT-TYPE
SYNTAX INTEGER {
reserved(1),
pending(2),
registered(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This fields describes the Tunnel's
current state.
reserved - visitor added,
authentication in progress
pending - authentication complete,
registration requisition has been sent
to gateway, tunnel not registered yet
registered - tunnel is up"
::= { anxTunnelEntry 5 }
anxTunnelMnIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP Address of the Remote Node."
::= { anxTunnelEntry 6 }
anxTunnelMnIPXAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPX Address of the Remote Node."
::= { anxTunnelEntry 7 }
anxTunnelHaAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP Address assigned to the Home Agent."
::= { anxTunnelEntry 8 }
-- ss7 MIB objects
ss7Pref1SigGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the primary SS7 gateway.
The default value is 0.0.0.0.
This MIB object corresponds to the NA/admin
parameter 'pref1_sig_gateway'."
::= { ss7 1 }
ss7Pref2SigGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the primary secondary SS7 gateway.
This may be zero if a redundant SS7 gateway is not
available.
The default value is 0.0.0.0.
This MIB object corresponds to the NA/admin
parameter 'pref2_sig_gateway'."
::= { ss7 2 }
ss7Pref1SigPort OBJECT-TYPE
SYNTAX INTEGER (1..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TCP port number used on the primary SS7 gateway.
The default is 1000.
This MIB object corresponds to the NA/admin parameter
'pref1_sig_port'."
::= { ss7 3 }
ss7Pref2SigPort OBJECT-TYPE
SYNTAX INTEGER (1..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TCP port number used on the secondary SS7 gateway.
The default is 1000. This entry is zero if no redundant
SS7 gateway is available.
This MIB object corresponds to the NA/admin parameter
'pref2_sig_port'."
::= { ss7 4 }
ss7SigKeepalive OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum time to wait for a packet to be received from
SS7 server. This value is in seconds. The default value is
15 seconds.
This MIB object corresponds to the NA/admin parameter
'sig_keepalive'."
::= { ss7 5 }
ss7CurrentGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The address of the current SS7 server. This can
change dynamically depending on the state of the
server."
::= { ss7 6 }
ss7ConnectionTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Time at which this connection was established
to the current SS7 Gateway."
::= { ss7 7 }
ss7Registration OBJECT-TYPE
SYNTAX INTEGER {
notregistered(1),
incoming(2),
both(3),
rasregreject(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes whether the RAS can accept and/or receive
calls. This is set by the ss7 gateway."
::= { ss7 8 }
ss7ChanTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ss7ChanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Table of ss7 Channel information."
::= { ss7 9 }
ss7ChanEntry OBJECT-TYPE
SYNTAX Ss7ChanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ss7 channel information."
INDEX { ss7WanIndex, ss7ChanNumber }
::= { ss7ChanTable 1 }
Ss7ChanEntry ::= SEQUENCE {
ss7WanIndex INTEGER,
ss7ChanNumber INTEGER,
ss7ChanStatus INTEGER,
ss7ChanState INTEGER
}
ss7WanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
Wan Module."
::= { ss7ChanEntry 1 }
ss7ChanNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index value which uniquely identifies the
Channel Numnber."
::= { ss7ChanEntry 2 }
ss7ChanStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
busy(2),
blocked(3),
blocking(4),
unblocking(5),
loopback(6),
restarting(7),
continuityTest(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the ds0 channel.
idle(1) - the DS0 is available for calls
busy(2) - call is in progress
blocked(3) - the RAS of the gateway requested block
unblocking(4) -
loopback(5) - loopback requested by the gateway
restarting(6) - DS0 restart requested by the gateway
continuityTest(7) - the RAS or the gateway requested continuity test
"
::= { ss7ChanEntry 3 }
ss7ChanState OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
connected(2),
waitReleaseComplete(3),
waitATConnect(4),
waitRelease(5),
waitConnect(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the ds0 channel.
idle(1) - no call in progress
connected(2) - call fully established.
waitReleaseComplete(3) - waiting for Release Complete
from gateway.
waitATConnect(4) - waiting for connect from WAN
manager.
waitRelease(5) - waiting for Release from gateway.
waitConnect(6) - waiting for connect from gateway."
::= { ss7ChanEntry 4 }
-- nfas MIB objects
nfasPref1SigGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the primary nfas gateway.
The default value is 0.0.0.0.
This MIB object corresponds to the NA/admin
parameter 'pref1_sig_gateway'."
::= { nfas 1 }
nfasPref2SigGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the backup nfas gateway.
The default value is 0.0.0.0.
This MIB object corresponds to the NA/admin
parameter 'pref2_sig_gateway'."
::= { nfas 2 }
nfasPref1SigPort OBJECT-TYPE
SYNTAX INTEGER (1..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TCP port number used on the primary nfas gateway.
This MIB object corresponds to the NA/admin parameter
'pref1_sig_port'."
::= { nfas 3 }
nfasPref2SigPort OBJECT-TYPE
SYNTAX INTEGER (1..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TCP port number used on the nfas backup gateway.
This MIB object corresponds to the NA/admin parameter
'pref2_sig_port'."
::= { nfas 4 }
nfasGroupName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is a trap to indicate the nfas group name."
::= { nfas 5 }
nfasDchannelstate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This will indicate whether this interface is
Active or Inactive : 1-Active, 2-Inactive."
::= { nfas 6 }
nfasConnectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF NfasConnectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of nfas connection information."
::= { nfas 7 }
nfasConnectionEntry OBJECT-TYPE
SYNTAX NfasConnectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The nfas connection information."
INDEX { nfasInterfaceNo }
::= { nfasConnectionTable 1 }
NfasConnectionEntry ::= SEQUENCE {
nfasInterfaceStatus DisplayString,
nfasIpAddress IpAddress,
nfasDchannelStatus DisplayString,
nfasConnectStatus DisplayString,
nfasInterfaceNo INTEGER
}
nfasInterfaceStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of interface - Primary,Backup or Bearer."
::= { nfasConnectionEntry 1 }
nfasIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP Address of the Interface."
::= { nfasConnectionEntry 2 }
nfasDchannelStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The D Channel Status - Active or Inactive."
::= { nfasConnectionEntry 3 }
nfasConnectStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The nfas connect status - Connected or Disconnected."
::= { nfasConnectionEntry 4 }
nfasInterfaceNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The nfas interface number which could be beween 0-19.
The Interface No for the primary is always 0."
::= { nfasConnectionEntry 5 }
nfasConnectionStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a trap to indicate the nfas connection status
between Primary,Backup and Bearer ."
::= { nfas 8 }
nfasBackupStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a trap to indicate the nfas switch-over status."
::= { nfas 9 }