-- File: xylo-wan.mib
|
|
-- Bay Networks Annex Private Enterprise MIB
|
|
--
|
|
-- Copyright 1991, 1993, 1994, 1995, 1996, 1997 Bay Networks, Inc.
|
|
-- ALL RIGHTS RESERVED.
|
|
--
|
|
-- ALL RIGHTS RESERVED. Licensed Material - Property of Bay Networks, Inc.
|
|
-- This software is made available solely pursuant to the terms of a
|
|
-- software license agreement which governs its use.
|
|
-- Unauthorized duplication, distribution or sale are strictly prohibited.
|
|
--
|
|
-- This information is subject to change without notice, and should
|
|
-- not be construed as a commitment by Bay Networks, Inc. Bay Networks, Inc.,
|
|
-- assumes no responsibility for any errors that may appear in this
|
|
-- document.
|
|
--
|
|
-- $Id:
|
|
--
|
|
|
|
XYLO-WAN-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
IpAddress, Counter
|
|
FROM RFC1155-SMI
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
anxt1, anxpri, anxtunnelport, ss7,nfas
|
|
FROM XYLO-MIB-SMI;
|
|
|
|
-- xylogics OBJECT IDENTIFIER ::= { enterprises 15 }
|
|
-- anxt1 OBJECT IDENTIFIER ::= { annex 11 }
|
|
-- anxpri OBJECT IDENTIFIER ::= { annex 12 }
|
|
-- anxtunnelport OBJECT IDENTIFIER ::= { annex 14 }
|
|
-- ss7 OBJECT IDENTIFIER ::= { annex 109 }
|
|
-- nfas OBJECT IDENTIFIER ::= { annex 111 }
|
|
|
|
-- PRI related groups.
|
|
|
|
connections OBJECT IDENTIFIER ::= { anxpri 1 }
|
|
globals OBJECT IDENTIFIER ::= { anxpri 2 }
|
|
|
|
-- xylogics private mib group for CSMIM-T1 support
|
|
--the T1-engine/E1/PRI group
|
|
-- Note the following objects are applicable to T1/E1 or PRI except
|
|
-- where noted otherwise.
|
|
|
|
anxt1Total OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of T1/PRI lines on this Annex."
|
|
::= { anxt1 1 }
|
|
|
|
anxt1ConfigT1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Anxt1ConfigT1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of T1 configuration parameters that
|
|
are not included in the DS1 MIB."
|
|
::= { anxt1 2 }
|
|
|
|
anxt1ConfigT1Entry OBJECT-TYPE
|
|
SYNTAX Anxt1ConfigT1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal T1 engine parameters."
|
|
INDEX { anxt1LineIndex }
|
|
::= { anxt1ConfigT1Table 1 }
|
|
|
|
Anxt1ConfigT1Entry ::= SEQUENCE {
|
|
anxt1LineIndex INTEGER,
|
|
anxt1AlarmSyslog INTEGER,
|
|
anxt1DiiLineCode INTEGER,
|
|
anxt1DiiFraming INTEGER,
|
|
anxt1DiiDistance INTEGER,
|
|
anxt1Ds1LineBuildout INTEGER,
|
|
anxt1Ds1OnesDensity INTEGER,
|
|
anxt1EngineBypass INTEGER,
|
|
anxt1UnitId DisplayString,
|
|
anxt1UnitSerialNumber DisplayString,
|
|
anxt1UpTime INTEGER,
|
|
anxt1Info DisplayString,
|
|
anxt1TotChan INTEGER,
|
|
anxt1ResetPRI INTEGER,
|
|
anxt1SwitchType INTEGER,
|
|
anxt1BlockInCalls INTEGER,
|
|
anxt1BlockOutCalls INTEGER,
|
|
anxt1LineLength INTEGER,
|
|
anxt1AnalogEncoding INTEGER,
|
|
anxt1PRIModuleType INTEGER,
|
|
anxt1CasDnisDigits INTEGER,
|
|
anxt1CasAniDigits INTEGER,
|
|
anxt1CasDigitWidth INTEGER,
|
|
anxt1CasInterDigit INTEGER,
|
|
anxt1CasDigitPower1 INTEGER,
|
|
anxt1CasDigitPower2 INTEGER,
|
|
anxt1CasBusySignalBits INTEGER,
|
|
anxt1CasPhoneNumber DisplayString,
|
|
anxt1Dsx1LineType INTEGER,
|
|
anxt1Ds1EsfFdl INTEGER,
|
|
anxt1TniCircuitId DisplayString,
|
|
anxt1TniClock INTEGER,
|
|
anxt1CallbackEnable INTEGER,
|
|
anxt1CasAniEnable INTEGER,
|
|
anxt1Nfasinterfaceid INTEGER,
|
|
anxt1Backupinterfaceid INTEGER
|
|
}
|
|
|
|
anxt1LineIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213)."
|
|
::= { anxt1ConfigT1Entry 1 }
|
|
|
|
|
|
anxt1AlarmSyslog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"If this object is set to yes(1), all
|
|
alarm events, red, yellow and blue, are
|
|
syslogged. In other words, the detection
|
|
of any one of the alarm events will
|
|
generate a syslog provided syslogs are
|
|
enabled. The default is yes(1).
|
|
Note:
|
|
1. The syslog is generated at warning level. That
|
|
means that anxSysLogMask should be atleast at Warning
|
|
level.
|
|
2. This object is supported for T1 modules only.
|
|
|
|
Corresponding na/admin parameter would be alarmsyslog."
|
|
|
|
::= { anxt1ConfigT1Entry 2 }
|
|
|
|
anxt1DiiLineCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
b8zs(1),
|
|
ami(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object selects the line code format
|
|
used on the T1 Drop and Insert Interface.
|
|
tni_line_coding is the na/admin corresponding
|
|
parameter. This object is supported for T1 modules only.
|
|
Note: For modules configured for PRI,
|
|
b8zs is the only valid option.
|
|
ami is valid only for channelized E1"
|
|
::= { anxt1ConfigT1Entry 3 }
|
|
|
|
anxt1DiiFraming OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
esf(1),
|
|
d4(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object controls the super frame format
|
|
used on the T1 Drop and Insert Interface.
|
|
tdi_framing is the na/admin corresp. parameter.
|
|
This object is supported for T1 modules only.
|
|
Note: For modules configured for PRI,
|
|
esf(1) is the only valid option."
|
|
::= { anxt1ConfigT1Entry 4 }
|
|
|
|
anxt1DiiDistance OBJECT-TYPE
|
|
SYNTAX INTEGER (0..655)
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The distance measured in feet of the cable
|
|
run to the equipment attached to the Drop
|
|
and Insert Interface. The default is 0.
|
|
tdi_distance is the corresp. na/admin parameter.
|
|
This object is supported for T1 modules only."
|
|
::= { anxt1ConfigT1Entry 5 }
|
|
|
|
anxt1Ds1LineBuildout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
zero-db(1),
|
|
sevendotfive-db(2),
|
|
fifteen-db(3),
|
|
twentytwodotfive-db(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"At instalation time, the telephone company
|
|
will supply a measured cable loss measurement
|
|
between the last line generator and the
|
|
customer location. This value, named line
|
|
buildout, is measured in db and may range
|
|
from 0 and 22.5 dbs.
|
|
tni_line_buildout is the corresp. na/admin parameter.
|
|
This object is supported for T1 modules only."
|
|
::= { anxt1ConfigT1Entry 6 }
|
|
|
|
anxt1Ds1OnesDensity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object allows the user to defeat
|
|
the ones density monitor.
|
|
The default is off but it should be
|
|
set to on when using the AMI line coding.
|
|
tni_ones_density would be corresp. na/admin parameter.
|
|
This object is supported for T1 modules only."
|
|
::= { anxt1ConfigT1Entry 7 }
|
|
|
|
anxt1EngineBypass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"when this object is set to yes the T1 engine
|
|
is taken out of the network. The Network
|
|
Interface is then physically coupled to
|
|
the Drop and Insert Interface, and the T1
|
|
engine has no effect on the T1 circuit.
|
|
bypass is the corresp. na/admin paramter.
|
|
This object is supported for T1 modules only."
|
|
::= { anxt1ConfigT1Entry 8 }
|
|
|
|
anxt1UnitId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a string indicating the firmware
|
|
version for the T1/PRI engine."
|
|
::= { anxt1ConfigT1Entry 9 }
|
|
|
|
anxt1UnitSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This is the 4 digit T1 engine serial number.
|
|
This object is supported for T1 modules only."
|
|
::= { anxt1ConfigT1Entry 10 }
|
|
|
|
anxt1UpTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates the up time in minutes for the T1 engine.
|
|
Doing a hard reset will reset this value.
|
|
Note: This value may not be same as sysupTime if a
|
|
hard reset has been done at any time after the annex
|
|
is brought up.
|
|
This object is supported for T1 modules only."
|
|
::= { anxt1ConfigT1Entry 11 }
|
|
|
|
anxt1Info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This objct specifies installation information
|
|
from the telephone company regarding the T1 line.
|
|
Corresponding na/admin parameter is t1_info.
|
|
This object is supported for T1 modules only."
|
|
::= { anxt1ConfigT1Entry 12 }
|
|
|
|
anxt1TotChan OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of internal DS0 channels on this WAN interface."
|
|
::= { anxt1ConfigT1Entry 13 }
|
|
|
|
anxt1ResetPRI OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this object to enable will reset the PRI
|
|
line. Setting the object to disable(2) will
|
|
disable the PRI line and make it unavailable."
|
|
::= { anxt1ConfigT1Entry 14 }
|
|
|
|
anxt1SwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default(1),
|
|
other(2),
|
|
sng(3),
|
|
ni2(4),
|
|
dms(5),
|
|
at9(6),
|
|
ets(7),
|
|
au1(8),
|
|
notused1(9),
|
|
ntt(10),
|
|
ets-ncrc4(11),
|
|
ust1(12),
|
|
hkt1(13),
|
|
twt1r1(14),
|
|
bbe1r2(15),
|
|
at4(16),
|
|
bre1r2(17),
|
|
kre1r2-1(18),
|
|
swe1p7(19),
|
|
ine1r2(20),
|
|
cne1r2(21),
|
|
nze1r2(22),
|
|
ust1fd(23),
|
|
ess-v10(24),
|
|
nosig(25),
|
|
br2e1r2(26),
|
|
kre1r2-2(27),
|
|
ide1r2(28),
|
|
phe1r2(29),
|
|
the1r2(30),
|
|
mye1r2(31),
|
|
are1r2(32),
|
|
mxe1r2(33),
|
|
ane1r2(34),
|
|
tre1r2(35),
|
|
ile1r2(36),
|
|
moe1r2(37),
|
|
ine1r2-1(38),
|
|
ine1r2-2(39),
|
|
ine1r2-3(40),
|
|
ine1r2-4(41),
|
|
twt1(42),
|
|
ust1fc(43),
|
|
ust1fdi(44),
|
|
ni2_nfas_primary(45),
|
|
ni2_nfas_backup(46),
|
|
dms_nfas_primary(47),
|
|
dms_nfas_backup(48)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Select the switch type compatibile with the
|
|
PRI service provider.
|
|
default(1) Will select the default switch chosen by the wan
|
|
manager based on the moduletype. If you set the
|
|
switchtype to default(1), reboot the box, and do an
|
|
snmpget on the switchtype, you can determine which
|
|
switchtype was chosen by the wan manager.
|
|
|
|
other(2) - For a GET, this value reflects the switch
|
|
type set through Cli/Admin which does not
|
|
match with other switches listed here.
|
|
For a SET the SNMP agent will ignore it
|
|
and will not change the current switch type
|
|
set through Cli/Admin.
|
|
|
|
switch_type description protocol
|
|
___________________________________________________________________
|
|
sng(3), Singapore E1 ISDN PRI
|
|
ni2(4), NI-2 (National ISDN 2) T1 ISDN PRI
|
|
dms(5), DMS-100 (Northern Telecom) T1 ISDN PRI
|
|
at9(6), 5ESS (AT&T 5ESS) T1 ISDN PRI
|
|
ets(7), ETSI E1 ISDN PRI
|
|
au1(8), Australia/AUSTEL E1 PRI PRI
|
|
ntt(10), Japan NTT PRI
|
|
ets-ncrc4(11), ETSI E1 ISDN w/o CRC4 PRI
|
|
ust1(12), US/North American Channelized T1 CAS
|
|
hkt1(13), Hong Kong Channelized T1 CAS
|
|
twt1r1(14), Taiwan T1/R1 CAS
|
|
bbe1r2(15), BlueBook/CCITT E1/R2 CAS
|
|
at4(16), 4ESS (AT&T 4ESS) T1 ISDN PRI
|
|
bre1r2(17), Brazil E1/R2 CAS
|
|
kre1r2-1(18), Korea E1/R2 CAS
|
|
swe1p7(19) Sweden E1 P7 CAS
|
|
ine1r2(20), Indonesia E1/R2 CAS
|
|
cne1r2(21), China E1/R2 CAS
|
|
nze1r2(22), New Zealand E1/R2 CAS
|
|
ust1fd(23), Unites States CAS
|
|
ess-v10(24),
|
|
nosig(25), SS7, No signaling required SS7
|
|
br2e1r2(26), Brazil E1/R2, 1 second wink CAS
|
|
kre1r2-2(27), Korea E1/R2 CAS
|
|
ide1r2(28), Indonesia CAS
|
|
phe1r2(29), Philippines CAS
|
|
the1r2(30), Thailand CAS
|
|
mye1r2(31), Malaysia CAS
|
|
are1r2(32), Argentina CAS
|
|
mxe1r2(33), Mexico CAS
|
|
ane1r2(34), St.Martin-Antilles CAS
|
|
tre1r2(35), Turkey CAS
|
|
ile1r2(36), Israel CAS
|
|
moe1r2(37), Macau CAS
|
|
ine1r2-1(38), India sig1 CAS
|
|
ine1r2-2(39), India sig2 CAS
|
|
ine1r2-3(40), India sig3 CAS
|
|
ine1r2-4(41), India sig4 CAS
|
|
twt1(42), Taiwan (wink) CAS
|
|
ust1fc(43), Unites States CAS
|
|
ust1fdi(44), Unites States CAS
|
|
ni2_nfas_primary(45), NI-2 (National ISDN 2) T1 ISDN PRI
|
|
ni2_nfas_backup(46), NI-2 (National ISDN 2) T1 ISDN PRI
|
|
dms_nfas_primary(47), DMS-100 (Northern Telecom) T1 ISDN PRI
|
|
dms_nfas_backup(48) DMS-100 (Northern Telecom) T1 ISDN PRI
|
|
|
|
This parameter is available on all platforms using
|
|
PRI module and platforms using the WAN module
|
|
configured for CAS or PRI. You must reset the box
|
|
for the new switch_type to take effect"
|
|
|
|
::= { anxt1ConfigT1Entry 15 }
|
|
|
|
anxt1BlockInCalls OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this object is set to enable, then the box
|
|
will stop accepting calls on this line. This will
|
|
prevent new users from logging in and should be used
|
|
to bring the box down gracefully. The default
|
|
is disable.
|
|
This object is supported for modules configured
|
|
for PRI."
|
|
::= { anxt1ConfigT1Entry 16 }
|
|
|
|
anxt1BlockOutCalls OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this object is set to enable, then the box
|
|
will not place any outgoing calls. This should be used
|
|
to bring the box down gracefully. The default
|
|
is disable.
|
|
This object is supported for modules configured
|
|
for PRI."
|
|
::= { anxt1ConfigT1Entry 17 }
|
|
|
|
anxt1LineLength OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
r0-25(1),
|
|
r26-65(2),
|
|
r66-100(3),
|
|
r101-135(4),
|
|
r136-165(5),
|
|
r166-185(6),
|
|
r186-210(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows the user to configure
|
|
the dsx1 line driver with the distance
|
|
between the annex and the external CSU. This paramater
|
|
should be left to default with annex's with internal CSU.
|
|
The parameter defines the line length in meters.
|
|
|
|
This MIB object corresponds to the na/admin
|
|
parameter dsx1_line_length.
|
|
|
|
This parameter is available on the ra6300, and on platforms
|
|
using the WAN module configured for CAS or PRI."
|
|
|
|
::= { anxt1ConfigT1Entry 18 }
|
|
|
|
anxt1AnalogEncoding OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(1),
|
|
mu-law(2),
|
|
a-law(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the type of encoding
|
|
to be used for analog (modem) calls. If this parameter
|
|
is not set then RA6300 will determine itself depending
|
|
on the PRI line that it terminates. For PRI line in
|
|
USA, this is set to mu-law and in Europe this will be
|
|
set to a-law.
|
|
This MIB object corresponds to the na/admin
|
|
parameter analog_encoding.
|
|
Default value is auto(1).
|
|
|
|
This parameter is available on the ra6300, and on platforms
|
|
using the WAN module configured for CAS or PRI."
|
|
|
|
::= { anxt1ConfigT1Entry 19 }
|
|
|
|
|
|
anxt1PRIModuleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
e1(1),
|
|
t1(2),
|
|
t1-intcsu(3),
|
|
e1-aust(4),
|
|
unused(5),
|
|
unused1(6),
|
|
unused2(7),
|
|
cas-t1-csu(8),
|
|
cas-e1(9),
|
|
sng-e1(10),
|
|
pri-e1-israel(11),
|
|
type-unknown(12)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object returns the module type on .
|
|
|
|
e1(1) means PRI module is for Europe,
|
|
t1(2) means PRI module is for USA with External CSU,
|
|
t1-intcsu(3) t1/PRI for USA with internal CSU.
|
|
e1-aust(4) e1/PRI for Australia.
|
|
cas-t1-csu(8) t1/CAS with internal csu.
|
|
cas-e1(9) e1/CAS.
|
|
|
|
This parameter is available on all platforms using
|
|
PRI module and platforms using the WAN module
|
|
configured for CAS or PRI. "
|
|
::= { anxt1ConfigT1Entry 20 }
|
|
|
|
anxt1CasDnisDigits OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows the user to configure the number of
|
|
DNIS digits that the channelized T1/E1 interface is provisioned
|
|
to provide. The default value is 0.
|
|
Typical values are between 4 - 10.
|
|
|
|
This MIB object corresponds to the na/admin
|
|
parameter dnis.
|
|
|
|
This parameter is available on platforms
|
|
using the WAN module configured for CAS."
|
|
|
|
::= { anxt1ConfigT1Entry 21 }
|
|
|
|
anxt1CasAniDigits OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This parameter allows the user to configure the number of
|
|
ANI digits that the channelized T1/E1 interface is provisioned
|
|
to provide. The default value is 0.
|
|
Typical values are between 4 - 10.
|
|
|
|
This MIB object corresponds to the na/admin
|
|
parameter ani.
|
|
|
|
This parameter is available on platforms
|
|
using the WAN module configured for CAS."
|
|
|
|
::= { anxt1ConfigT1Entry 22 }
|
|
|
|
|
|
anxt1CasDigitWidth OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows the width of each digit generated by
|
|
the WAN module to be adjusted. The default value is 0.
|
|
|
|
This MIB object corresponds to the na/admin
|
|
parameter digit_width.
|
|
|
|
This parameter is available on platforms
|
|
using the WAN module configured for CAS."
|
|
|
|
::= { anxt1ConfigT1Entry 23 }
|
|
|
|
|
|
anxt1CasInterDigit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows the distance between each digit
|
|
generated by the WAN module to be adjusted. The default
|
|
value is 0.
|
|
|
|
This MIB object corresponds to the na/admin
|
|
parameter inter_digit.
|
|
|
|
This parameter is available on platforms
|
|
using the WAN module configured for CAS."
|
|
|
|
::= { anxt1ConfigT1Entry 24 }
|
|
|
|
anxt1CasDigitPower1 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows the power level of the FIRST tone
|
|
of each digit generated by the WAN module to be adjusted.
|
|
The default value is 0.
|
|
|
|
This MIB object corresponds to the na/admin
|
|
parameter digit_power_1.
|
|
|
|
This parameter is available on platforms
|
|
using the WAN module configured for CAS."
|
|
|
|
::= { anxt1ConfigT1Entry 25 }
|
|
|
|
anxt1CasDigitPower2 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows the power level of the SECOND tone
|
|
of each digit generated by the WAN module to be adjusted.
|
|
The default value is 0.
|
|
|
|
This MIB object corresponds to the na/admin
|
|
parameter digit_power_2.
|
|
|
|
This parameter is available on platforms
|
|
using the WAN module configured for CAS."
|
|
|
|
::= { anxt1ConfigT1Entry 26 }
|
|
|
|
|
|
anxt1CasBusySignalBits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bits00(1),
|
|
bits01(2),
|
|
bits10(3),
|
|
bits11(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An enumerated integer that defines the type of
|
|
busy signal.
|
|
|
|
This MIB object corresponds to the na/admin
|
|
parameter busy_signal_bits.
|
|
|
|
This parameter is available on platforms using the
|
|
WAN module configured for CAS."
|
|
::= { anxt1ConfigT1Entry 27 }
|
|
|
|
|
|
anxt1CasPhoneNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The local phone number of the WAN interface.
|
|
|
|
This MIB object corresponds to the na/admin parameter
|
|
local_phone_number.
|
|
|
|
This parameter is available on platforms using the
|
|
WAN module configured for CAS."
|
|
::= { anxt1ConfigT1Entry 28 }
|
|
|
|
anxt1Dsx1LineType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
eSF(2),
|
|
d4(3),
|
|
dDF(4),
|
|
mFF-CRC4(5),
|
|
mFF-CRC4-G706(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable indicates the variety of DS1
|
|
Line implementing this circuit. The type of
|
|
circuit affects the number of bits per second
|
|
that the circuit can reasonably carry, as well
|
|
as the interpretation of the usage and error
|
|
statistics. The values, in sequence, describe:
|
|
|
|
TITLE: rfc1406 TITLE: SPECIFICATION:
|
|
|
|
ESF(2) dsx1ESF Extended SuperFrame DS1
|
|
|
|
D4(3) dsx1D4 AT&T D4 format DS1
|
|
|
|
DDF(4) dsx1E1/ CCITT Recommendation G.704
|
|
dsxE1-MF (Table 4a)
|
|
|
|
MFF-CRC4(5) dsx1E1-CRC/ CCITT Recommendation G.704
|
|
dsx1E1-CRC-MF (Table 4b)
|
|
|
|
MFF-CRC4-G706(6) N/A 5399 WAN Module Func. Spec."
|
|
|
|
::= { anxt1ConfigT1Entry 29 }
|
|
|
|
|
|
anxt1Ds1EsfFdl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
att(1),
|
|
ansi(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The NA parameter is tni_esf_fdl (channelized T1 category):
|
|
This specifies one of two standards when running ESF framing
|
|
on the T1 Network Interface: Valid options are ansi, att "
|
|
::= { anxt1ConfigT1Entry 30 }
|
|
|
|
anxt1TniCircuitId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The NA parameter is tni_circuit_id (channelized T1 category):
|
|
This is a ascii string with circuit id provided by the
|
|
telephone company. Up to 127 bytes.
|
|
This object is supported for T1 engines only."
|
|
::= { anxt1ConfigT1Entry 31 }
|
|
|
|
anxt1TniClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
loop(1),
|
|
local(2),
|
|
external(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The NA parameter is tni_clock (channelized T1 category):
|
|
This specifies the T1 engine clock source: loop, local,
|
|
external.
|
|
This object is supported for T1 engines only."
|
|
::= { anxt1ConfigT1Entry 32 }
|
|
|
|
anxt1CallbackEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this object is set to enable, the WAN interface may be
|
|
selected to handle a callback pending port availability.
|
|
When set to disable, the associated WAN interface cannot be
|
|
selected as a callback resource. The default is disable.
|
|
|
|
This MIB object corresponds to the NA/admin WAN
|
|
parameter 'callback_enable'."
|
|
::= { anxt1ConfigT1Entry 33 }
|
|
|
|
|
|
anxt1CasAniEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows the user to configure whether or not to
|
|
allow CAS ANI digits, (per provisioning). The default is disable.
|
|
|
|
This MIB object corresponds to the na/admin WAN
|
|
parameter 'ani'.
|
|
|
|
This parameter is available on platforms
|
|
using the WAN module configured for CAS."
|
|
|
|
::= { anxt1ConfigT1Entry 34 }
|
|
|
|
anxt1Nfasinterfaceid OBJECT-TYPE
|
|
SYNTAX INTEGER (0..19)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a configurable parameter for NFAS.
|
|
This MIB object corresponds to the NA/admin WAN
|
|
parameter 'nfas_interface_id'."
|
|
|
|
::= { anxt1ConfigT1Entry 35 }
|
|
|
|
anxt1Backupinterfaceid OBJECT-TYPE
|
|
SYNTAX INTEGER (1..19)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a configurable parameter for NFAS.
|
|
This MIB object corresponds to the NA/admin WAN
|
|
parameter 'backup_interface_id'."
|
|
|
|
::= { anxt1ConfigT1Entry 36 }
|
|
|
|
|
|
-- The DS0's group
|
|
|
|
anxt1ChanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Anxt1ChanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of DS0 channel entries."
|
|
::= { anxt1 3 }
|
|
|
|
anxt1ChanEntry OBJECT-TYPE
|
|
SYNTAX Anxt1ChanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal T1 engine parameters."
|
|
INDEX { anxt1ChanIndex, anxt1ChanNumber }
|
|
::= { anxt1ChanTable 1 }
|
|
|
|
Anxt1ChanEntry ::= SEQUENCE {
|
|
anxt1ChanIndex INTEGER,
|
|
anxt1ChanNumber INTEGER,
|
|
anxt1ChanMap OCTET STRING,
|
|
anxt1ChanSigProto INTEGER,
|
|
anxt1ChanRing INTEGER,
|
|
anxt1ChanIpAddr IpAddress,
|
|
anxt1ChanIpxNetwork DisplayString,
|
|
anxt1ChanIpxNode DisplayString,
|
|
anxt1ChanStatus INTEGER,
|
|
anxt1ChanState INTEGER,
|
|
anxt1ChanSeize Counter,
|
|
anxt1ChanRingCount Counter,
|
|
anxt1ChanAssign Counter,
|
|
anxt1ChanConnect Counter,
|
|
anxt1ChanChat Counter,
|
|
anxt1ChanDcd Counter,
|
|
anxt1ChanModemCall Counter,
|
|
anxt1ChanConsecFail Counter
|
|
}
|
|
|
|
anxt1ChanIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
WAN interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module."
|
|
|
|
::= { anxt1ChanEntry 1 }
|
|
|
|
anxt1ChanNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique number from 1 to anxt1TotChan that
|
|
identifies each internal DS0 channel on a WAN interface."
|
|
::= { anxt1ChanEntry 2 }
|
|
|
|
anxt1ChanMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object specifies the mapping between the DS0
|
|
in the DS1 interface, the DS0 in the DI interface,
|
|
and the modems. The DS0 is identified by anxt1ChanIfIndex
|
|
and anxt1ChanNumber. This object has two 8-bit fields.
|
|
The high byte specifies the mapping:
|
|
unused(1),
|
|
ds1_modem(2), (ds1 to modem)
|
|
di_modem(3), (di to modem)
|
|
voice(4), (ds1 to di with voice signaling)
|
|
data(5) (ds1 to di with data signaling)
|
|
The low byte is used only when the high byte specifies
|
|
ds1_modem or di_modem and should be ignored in all other
|
|
cases. The low byte specifies the modem number (same as
|
|
port number) being mapped to the DS0.
|
|
|
|
Note: when the type is set to either voice, data or unused
|
|
agent expects zeros in the modem octet eg:'0400'
|
|
Corresp. na/admin parameter is the map.
|
|
This object is only valid for T1 products."
|
|
::= { anxt1ChanEntry 3 }
|
|
|
|
anxt1ChanSigProto OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
loop-loop(22),
|
|
loop-none(21),
|
|
none-loop(12),
|
|
ground-ground(33),
|
|
ground-none(31),
|
|
none-ground(13),
|
|
wink-wink(44),
|
|
wink-none(41),
|
|
none-wink(14),
|
|
immed-none(51),
|
|
none-immed(15),
|
|
none-none(11)
|
|
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is meaningful only when anxt1ChanMap is set
|
|
to ds1_modem or di_modem and should be ignored in all
|
|
other cases. The supported protocols are:
|
|
none(1),
|
|
loop_start(2),
|
|
ground_start(3),
|
|
wink_start(4),
|
|
immediate_start(5)
|
|
Note: following combinations are considered valid:
|
|
Value InSig octet OutSig octet
|
|
----- ----------- ------------
|
|
22 loop_start loop_start
|
|
21 loop_start none
|
|
12 none loop_start
|
|
33 ground ground
|
|
31 ground none
|
|
13 none ground
|
|
44 wink wink
|
|
41 wink none
|
|
14 none wink
|
|
51 immediate none
|
|
15 none immediate
|
|
11 none none
|
|
sigproto is the na/admin corresponding parameter.
|
|
This object is not valid for RA6300 only."
|
|
::= { anxt1ChanEntry 4 }
|
|
|
|
anxt1ChanRing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
diable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is meaningful only when anxt1ChanMap is set
|
|
to ds1-modem or di-modem and should be ignored in all
|
|
other cases. This object specifies if the Annex should
|
|
provide the audible ring to the central office on incoming
|
|
calls. The default is NO.
|
|
Corresp. na/admin parameter is the ring.
|
|
|
|
This parameter is available on the ra6300, and on platforms
|
|
using the WAN module configured for PRI."
|
|
|
|
::= { anxt1ChanEntry 5 }
|
|
|
|
anxt1ChanIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object returns the IP address
|
|
associated with the B Channel. When needed, this
|
|
IP address will be used for calls over the B channel.
|
|
|
|
This parameter is available on the ra6300, and on platforms
|
|
using the WAN module (configured for CAS or PRI)."
|
|
|
|
::= { anxt1ChanEntry 6 }
|
|
|
|
anxt1ChanIpxNetwork OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..8))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX network number for an IPX PPP connection
|
|
using this port. When the IPX PPP connection is
|
|
established the network number will be negotiated.
|
|
If one end of the connection is set to zero then
|
|
the value from the other end of the connection will
|
|
be used.
|
|
The value of this object is an 8 digit hexadecimal
|
|
number string representing the IPX network segment
|
|
assigned to this port. The value must be unique
|
|
across the network domain.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'ppp_ipx_network'."
|
|
::= { anxt1ChanEntry 7 }
|
|
|
|
anxt1ChanIpxNode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(11..17))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX node number for an IPX PPP connection
|
|
using this port.
|
|
The value of this object is a 12 digit
|
|
hexadecimal number string representing the IPX
|
|
node number assigned to this port.
|
|
Note the string is expected in the form:
|
|
12-3a-4-7-89-23.Each part of the address
|
|
must be a hex value separated by a hyphen.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'ppp_ipx_node'."
|
|
::= { anxt1ChanEntry 8 }
|
|
|
|
anxt1ChanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
used(1),
|
|
unused(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object returns the status of the
|
|
B channel. This is a read-only object that
|
|
indicates whether the channel is in use or not."
|
|
::= { anxt1ChanEntry 9 }
|
|
|
|
anxt1ChanState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
available(1),
|
|
busied-out(2),
|
|
auto-busied-out(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object reflects the state of the
|
|
B channel. Available means it is open
|
|
for use, busied-out means it was manually
|
|
taken out of the pool for use, and
|
|
auto-busied-out means the box removed
|
|
this channel for use because there are
|
|
more channels than modems available.
|
|
This object can be set and changes the state of
|
|
the channel. auto-busied-out cannot be set by a user."
|
|
::= { anxt1ChanEntry 10 }
|
|
|
|
anxt1ChanSeize OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SEIZE message from a WAN module to a WAN
|
|
manager process on the main processor,
|
|
indicating that the central office switch
|
|
has sent a channelized T1/E1 seize event."
|
|
::= { anxt1ChanEntry 11 }
|
|
|
|
anxt1ChanRingCount OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RING message from a WAN module to a WAN
|
|
manager process on the main processor,
|
|
indicating that a call has arrived. Successful
|
|
completion of assigning a modem and starting a
|
|
session."
|
|
::= { anxt1ChanEntry 12 }
|
|
|
|
anxt1ChanAssign OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"No modems were available for assignment.
|
|
This is caused by not having enough modems
|
|
or modems being removed from the pool "
|
|
::= { anxt1ChanEntry 13 }
|
|
|
|
anxt1ChanConnect OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"CONNECT message from the WAN module to the
|
|
WAN manager process, meaning the 5399 has
|
|
accepted the call and the WAN module and the
|
|
telephone company switch have agreed that the
|
|
call is up."
|
|
::= { anxt1ChanEntry 14 }
|
|
|
|
anxt1ChanChat OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"There was a modem error and the call was
|
|
terminated. Possibly caused by the modem."
|
|
::= { anxt1ChanEntry 15 }
|
|
|
|
anxt1ChanDcd OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Modem did not establish a connection with
|
|
it's peer. Lots of possible causes:
|
|
many possible causes:
|
|
modem error
|
|
bad data from bad channel
|
|
end-to-end line quality low
|
|
caller hung up
|
|
calling device wasn't a modem "
|
|
::= { anxt1ChanEntry 16 }
|
|
|
|
anxt1ChanModemCall OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times an incoming modem
|
|
call failed before getting all the way
|
|
to DCD."
|
|
::= { anxt1ChanEntry 17 }
|
|
|
|
anxt1ChanConsecFail OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times an incoming non-modem
|
|
call failed before successfully assigning
|
|
a device."
|
|
::= { anxt1ChanEntry 18 }
|
|
|
|
|
|
|
|
-- The extended current statistics group
|
|
-- This table is available only on WAN module platforms.
|
|
|
|
anxt1CurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Anxt1CurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of extended T1 current statistics.
|
|
This table is valid for WAN module platforms only."
|
|
::= { anxt1 4 }
|
|
|
|
anxt1CurrentEntry OBJECT-TYPE
|
|
SYNTAX Anxt1CurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal T1 engine extended current statistics."
|
|
INDEX { anxt1CurrentIndex }
|
|
::= { anxt1CurrentTable 1 }
|
|
|
|
Anxt1CurrentEntry ::= SEQUENCE {
|
|
anxt1CurrentIndex INTEGER,
|
|
anxt1CurrentOofs Counter,
|
|
anxt1CurrentBpvs Counter,
|
|
anxt1CurrentCrcs Counter,
|
|
anxt1CurrentCs Counter,
|
|
anxt1CurrentRnacs Counter,
|
|
anxt1CurrentEsfs Counter,
|
|
anxt1CurrentLofcs Counter
|
|
}
|
|
|
|
anxt1CurrentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { anxt1CurrentEntry 1 }
|
|
|
|
anxt1CurrentOofs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An Out Of Frame (OOF) event begins when any two
|
|
of four consecutive frame synchronizing bits are
|
|
received from the network interface are incorrect.
|
|
An OOF state ends when reframe occurs."
|
|
::= { anxt1CurrentEntry 2 }
|
|
|
|
anxt1CurrentBpvs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A BiPolar Violations error event for an AMI-coded
|
|
signal is the occurence of a pulse of the same polarity
|
|
as the previous pulse. A BPV error event for a B8ZS or
|
|
HDB3 coded signal is the occurence of a pulse of the
|
|
same polarity as the previous pulse without being a
|
|
part of the zero substitution code."
|
|
::= { anxt1CurrentEntry 3 }
|
|
|
|
anxt1CurrentCrcs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A CRC error occurs when the CRC field calculated
|
|
by the customer installation, based on the incoming
|
|
DS1 signal does not agree with the CRC field contained
|
|
in the DS1 signal received from the network."
|
|
::= { anxt1CurrentEntry 4 }
|
|
|
|
anxt1CurrentCs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Controlled Slips is the occcurence of a replication
|
|
or deletion of a DS1 frame by the receiving terminal."
|
|
::= { anxt1CurrentEntry 5 }
|
|
|
|
anxt1CurrentRnacs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Receive Network Alarm seconds is the count of seconds
|
|
with at least one alarm event occurring in a second."
|
|
::= { anxt1CurrentEntry 6 }
|
|
|
|
anxt1CurrentEsfs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of extended superframe errors in the current
|
|
interval."
|
|
::= { anxt1CurrentEntry 7 }
|
|
|
|
anxt1CurrentLofcs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of loss of framing errors in the current
|
|
interval."
|
|
::= { anxt1CurrentEntry 8 }
|
|
|
|
|
|
-- The extended total statistics group
|
|
-- This table is available on WAN module platforms only.
|
|
|
|
anxt1IntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Anxt1IntervalEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of extended T1 interval statistics.
|
|
This table is valid for WAN module platforms only."
|
|
::= { anxt1 5 }
|
|
|
|
anxt1IntervalEntry OBJECT-TYPE
|
|
SYNTAX Anxt1IntervalEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal T1 engine extended interval statistics."
|
|
INDEX { anxt1IntervalIndex, anxt1IntervalNumber }
|
|
::= { anxt1IntervalTable 1 }
|
|
|
|
Anxt1IntervalEntry ::= SEQUENCE {
|
|
anxt1IntervalIndex INTEGER,
|
|
anxt1IntervalNumber INTEGER,
|
|
anxt1IntervalOofs Counter,
|
|
anxt1IntervalBpvs Counter,
|
|
anxt1IntervalCrcs Counter,
|
|
anxt1IntervalCs Counter,
|
|
anxt1IntervalRnacs Counter,
|
|
anxt1IntervalEsfs Counter,
|
|
anxt1IntervalLofcs Counter
|
|
}
|
|
|
|
anxt1IntervalIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { anxt1IntervalEntry 1 }
|
|
|
|
anxt1IntervalNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { anxt1IntervalEntry 2 }
|
|
|
|
anxt1IntervalOofs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An Out Of Frame (OOF) event begins when any two
|
|
of four consecutive frame synchronizing bits are
|
|
received from the network interface are incorrect.
|
|
An OOF state ends when reframe occurs."
|
|
::= { anxt1IntervalEntry 3 }
|
|
|
|
anxt1IntervalBpvs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A BiPolar Violations error event for an AMI-coded
|
|
signal is the occurence of a pulse of the same polarity
|
|
as the previous pulse. A BPV error event for a B8ZS or
|
|
HDB3 coded signal is the occurence of a pulse of the
|
|
same polarity as the previous pulse without being a
|
|
part of the zero substitution code."
|
|
::= { anxt1IntervalEntry 4 }
|
|
|
|
anxt1IntervalCrcs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A CRC error occurs when the CRC field calculated
|
|
by the customer installation, based on the incoming
|
|
DS1 signal does not agree with the CRC field contained
|
|
in the DS1 signal received from the network."
|
|
::= { anxt1IntervalEntry 5 }
|
|
|
|
anxt1IntervalCs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Controlled Slips is the occcurence of a replication
|
|
or deletion of a DS1 frame by the receiving terminal."
|
|
::= { anxt1IntervalEntry 6 }
|
|
|
|
anxt1IntervalRnacs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Receive Network Alarm seconds is the count of seconds
|
|
with at least one alarm event occurring in a second."
|
|
::= { anxt1IntervalEntry 7 }
|
|
|
|
anxt1IntervalEsfs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of extended superframe errors in this interval."
|
|
::= { anxt1IntervalEntry 8 }
|
|
|
|
anxt1IntervalLofcs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of loss of framing errors in this interval."
|
|
::= { anxt1IntervalEntry 9 }
|
|
|
|
-- The extended total statistics group
|
|
-- Table is available on WAN module platforms only.
|
|
|
|
anxt1TotalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Anxt1TotalEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of extended T1 total statistics.
|
|
This table is valid for WAN module platforms only."
|
|
::= { anxt1 6 }
|
|
|
|
anxt1TotalEntry OBJECT-TYPE
|
|
SYNTAX Anxt1TotalEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal T1 engine extended total statistics."
|
|
INDEX { anxt1TotalIndex }
|
|
::= { anxt1TotalTable 1 }
|
|
|
|
Anxt1TotalEntry ::= SEQUENCE {
|
|
anxt1TotalIndex INTEGER,
|
|
anxt1TotalOofs Counter,
|
|
anxt1TotalBpvs Counter,
|
|
anxt1TotalCrcs Counter,
|
|
anxt1TotalCs Counter,
|
|
anxt1TotalRnacs Counter,
|
|
anxt1TotalEsfs Counter,
|
|
anxt1TotalLofcs Counter
|
|
}
|
|
|
|
anxt1TotalIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { anxt1TotalEntry 1 }
|
|
|
|
anxt1TotalOofs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An Out Of Frame (OOF) event begins when any two
|
|
of four consecutive frame synchronizing bits are
|
|
received from the network interface are incorrect.
|
|
An OOF state ends when reframe occurs."
|
|
::= { anxt1TotalEntry 2 }
|
|
|
|
anxt1TotalBpvs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A BiPolar Violations error event for an AMI-coded
|
|
signal is the occurence of a pulse of the same polarity
|
|
as the previous pulse. A BPV error event for a B8ZS or
|
|
HDB3 coded signal is the occurence of a pulse of the
|
|
same polarity as the previous pulse without being a
|
|
part of the zero substitution code."
|
|
::= { anxt1TotalEntry 3 }
|
|
|
|
anxt1TotalCrcs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A CRC error occurs when the CRC field calculated
|
|
by the customer installation, based on the incoming
|
|
DS1 signal does not agree with the CRC field contained
|
|
in the DS1 signal received from the network."
|
|
::= { anxt1TotalEntry 4 }
|
|
|
|
anxt1TotalCs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Controlled Slips is the occcurence of a replication
|
|
or deletion of a DS1 frame by the receiving terminal."
|
|
::= { anxt1TotalEntry 5 }
|
|
|
|
anxt1TotalRnacs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Receive Network Alarm seconds is the count of seconds
|
|
with at least one alarm event occurring in a second."
|
|
::= { anxt1TotalEntry 6 }
|
|
|
|
anxt1TotalEsfs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total count of extended superframe errors."
|
|
::= { anxt1TotalEntry 7 }
|
|
|
|
anxt1TotalLofcs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total count of loss of framing errors."
|
|
::= { anxt1TotalEntry 8 }
|
|
|
|
|
|
-- anxt1WanModuleTable
|
|
|
|
anxt1WanModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Anxt1WanModuleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table is is used to cross reference a WAN
|
|
module to its ifindex."
|
|
::= { anxt1 7 }
|
|
|
|
anxt1WanModuleEntry OBJECT-TYPE
|
|
SYNTAX Anxt1WanModuleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WAN module table entry."
|
|
INDEX { anxt1WanIndex }
|
|
::= { anxt1WanModuleTable 1 }
|
|
|
|
Anxt1WanModuleEntry ::= SEQUENCE {
|
|
anxt1WanIndex INTEGER,
|
|
anxt1WanIfIndex INTEGER
|
|
}
|
|
|
|
anxt1WanIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the index of the physical WAN module in
|
|
any BAY remote access product that uses WAN modules.
|
|
The range is 1 - anxt1Total (number of WAN modules in box)"
|
|
::= { anxt1WanModuleEntry 1 }
|
|
|
|
anxt1WanIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object can be used in place of Ifindex to find
|
|
the interface number of a WAN module."
|
|
::= { anxt1WanModuleEntry 2 }
|
|
|
|
anxt1TotalChannels OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of channels (Ds0's) on the this box
|
|
(or blade)."
|
|
::= { anxt1 8}
|
|
|
|
anxt1BusiedOutChannels OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of channels that are busied out.
|
|
anxt1TotalChannels - anxt1BusiedOutChannels =
|
|
Number of available channels"
|
|
::= { anxt1 9}
|
|
|
|
wanStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WanStatEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Wan Module statistics.
|
|
This table is valid for WAN module platforms only."
|
|
::= { anxt1 10 }
|
|
|
|
wanStatEntry OBJECT-TYPE
|
|
SYNTAX WanStatEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal T1 engine extended current statistics."
|
|
INDEX { wanStatIndex }
|
|
::= { wanStatTable 1 }
|
|
|
|
WanStatEntry ::= SEQUENCE {
|
|
wanStatIndex INTEGER,
|
|
wanStatInterfaceErrs Counter,
|
|
wanStatAcceptedInCalls Counter,
|
|
wanStatRejectedInCalls Counter,
|
|
wanStatAcceptedOutCalls Counter,
|
|
wanStatRejectedOutCalls Counter,
|
|
wanStatNormalCallDisconnects Counter,
|
|
wanStatAbNormalCallDisconnects Counter,
|
|
wanStatBchansCurrAllocated INTEGER,
|
|
wanStatNumTimesWanFull Counter
|
|
}
|
|
|
|
wanStatIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ifIndex value in the interfaces
|
|
table.
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { wanStatEntry 1 }
|
|
|
|
wanStatInterfaceErrs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This counter is incremented when ever an
|
|
error occurs between the wan module and the
|
|
PRI manager."
|
|
::= { wanStatEntry 2 }
|
|
|
|
wanStatAcceptedInCalls OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of incoming calls accepted by the call handler.
|
|
(call handler is generic term for all types of signaling
|
|
methods)"
|
|
::= { wanStatEntry 3 }
|
|
|
|
wanStatRejectedInCalls OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of incoming calls rejected by the call handler.
|
|
(call handler is generic term for all types of signaling
|
|
methods)"
|
|
::= { wanStatEntry 4 }
|
|
|
|
wanStatAcceptedOutCalls OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of outgoing calls accepted by the call handler.
|
|
(call handler is generic term for all types of signaling
|
|
methods)"
|
|
::= { wanStatEntry 5 }
|
|
|
|
wanStatRejectedOutCalls OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of outgoing calls rejected by the call handler.
|
|
(call handler is generic term for all types of signaling
|
|
methods)"
|
|
::= { wanStatEntry 6 }
|
|
|
|
wanStatNormalCallDisconnects OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of normal disconnects.
|
|
|
|
Normal Disconnects cause codes:
|
|
- NORMAL_CALL_CLEARING_CCOD"
|
|
::= { wanStatEntry 7 }
|
|
|
|
wanStatAbNormalCallDisconnects OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of abnormal disconnects.
|
|
|
|
Abnormal Disconnects cause codes:
|
|
- INVALID_NUMBER_FORMAT_CCODE
|
|
- NO_CKT_CHAN_AVAIL_CCODE
|
|
- REQ_CHAN_NOT_AVAIL_CCODE"
|
|
::= { wanStatEntry 8 }
|
|
|
|
wanStatBchansCurrAllocated OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of B channels currently allocated."
|
|
::= { wanStatEntry 9 }
|
|
|
|
wanStatNumTimesWanFull OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of times this wan has had all B channels
|
|
allocated since the wan_manager process was started
|
|
on the wan module. The wan_manager process is
|
|
started at boot time or by using the cli
|
|
-control- command to stop it and restart
|
|
it on a given wan module."
|
|
::= { wanStatEntry 10 }
|
|
|
|
|
|
-- PRI related groups.
|
|
-- Call connection table.
|
|
-- Active connection/call parameter group.
|
|
-- Only the active connection/call on a B channel will be returned.
|
|
-- All the tables in this group are indexed by line.channel number.
|
|
|
|
|
|
callGenericTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallGenericEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries of generic parameters for
|
|
active calls."
|
|
::= { connections 1 }
|
|
|
|
callGenericEntry OBJECT-TYPE
|
|
SYNTAX CallGenericEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The call's generic parameters."
|
|
INDEX { callGenericLineIdx, callGenericIdx }
|
|
::= { callGenericTable 1 }
|
|
|
|
CallGenericEntry ::= SEQUENCE {
|
|
callGenericLineIdx INTEGER,
|
|
callGenericIdx INTEGER,
|
|
callGenericMode INTEGER,
|
|
callGenericLocation DisplayString,
|
|
callGenericTermVar DisplayString,
|
|
callGenericPrompt DisplayString,
|
|
callGenericAllowBcast INTEGER,
|
|
callGenericImask7Bits INTEGER,
|
|
callGenericCliImask7 INTEGER,
|
|
callGenericBanner INTEGER,
|
|
callGenericTcpKeepAlive INTEGER,
|
|
callGenericDedicatedArgs DisplayString,
|
|
callGenericModemVar DisplayString,
|
|
callGenericDefSessMode INTEGER,
|
|
callGenericResolveProtocol INTEGER,
|
|
callGenericMaxSession INTEGER,
|
|
callGenericSpeed DisplayString,
|
|
callGenericAutoBaud INTEGER,
|
|
callGenericJobs DisplayString,
|
|
callGenericLineType INTEGER
|
|
}
|
|
|
|
callGenericLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callGenericEntry 1 }
|
|
|
|
callGenericIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callGenericEntry 2 }
|
|
|
|
callGenericMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cli(1),
|
|
slave(2),
|
|
adaptive(3),
|
|
unused(4),
|
|
slip(5),
|
|
ppp(7),
|
|
arap(8),
|
|
invalid(9),
|
|
auto-detect(10),
|
|
auto-adapt(11),
|
|
ipx(13),
|
|
call(14),
|
|
connect(15),
|
|
rlogin(16),
|
|
telnet(17),
|
|
tn3270(18)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode assigned to the port. Valid only
|
|
if the port type is async, or ta. The default
|
|
is cli.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'mode'.
|
|
|
|
Note: Values 6 and 12 are not used."
|
|
::= { callGenericEntry 3 }
|
|
|
|
callGenericLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive string for this port. This
|
|
string is displayed by the CLI who command.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
location."
|
|
::= { callGenericEntry 4 }
|
|
|
|
callGenericTermVar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string defining the type of terminal
|
|
attached to the serial/ta port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'term_var'.
|
|
Note: This object is not valid if the port type
|
|
is synchronous."
|
|
::= { callGenericEntry 5 }
|
|
|
|
callGenericPrompt OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines a port-specific prompt
|
|
string. The prompt string consists of displayable
|
|
characters and embedded formatting codes. Each
|
|
formatting code is stored in a single character
|
|
in nonvolatile memory. The maximum number of
|
|
characters stored for the prompt string
|
|
is 16. Since the formatting codes consist of
|
|
a '%' prepended to a single character, the maximum
|
|
length string that may be entered for this object
|
|
is 32 characters. Strings less than 32
|
|
characters in length will be rejected as bad values
|
|
if they cannot be stored into 16 characters in
|
|
nonvolatile memory after the formatting codes are
|
|
compressed into single characters.
|
|
|
|
The valid formatting codes are:
|
|
|
|
%a the string 'annex'
|
|
%c the string ': '
|
|
%d the date and time
|
|
%i the Annex's IP address
|
|
%j a newline character
|
|
%l port location, or 'port n'
|
|
%n the Annex's name
|
|
%p the port number
|
|
%r the string 'port'
|
|
%s a space
|
|
%t the time hh:mm:ss
|
|
%u the user name for port
|
|
%% the string '%'
|
|
|
|
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'prompt'.
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { callGenericEntry 6 }
|
|
|
|
|
|
callGenericAllowBcast OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether the serial/ta port can
|
|
receive administrative broadcast messages.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'allow_broadcast'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { callGenericEntry 8 }
|
|
|
|
callGenericImask7Bits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, instructs the Annex to ignore
|
|
the eighth bit of all received characters
|
|
on the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'imask_7bits'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { callGenericEntry 10 }
|
|
|
|
callGenericCliImask7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines whether input at the CLI is masked to
|
|
7 bits. The default is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'cli_imask7' The
|
|
default value for this object is enabled.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { callGenericEntry 11 }
|
|
|
|
|
|
callGenericBanner OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
beforesec(3),
|
|
aftersec(4),
|
|
motd-before-sec(5),
|
|
motd-after-sec(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies whether the Annex banner and message-
|
|
of-the-day are displayed on the channel. The
|
|
default is enabled.
|
|
This has four possible actions:
|
|
|
|
default, Y, yes, unset: banner before security,
|
|
motd after
|
|
none, N: no banner or motd
|
|
beforesec: banner and motd before
|
|
security
|
|
aftersec: banner and motd after
|
|
security
|
|
motd-before-sec: motd before security; no
|
|
banner
|
|
motd-after-sec: motd after security; no
|
|
banner
|
|
This MIB object corresponds to the NA/admin
|
|
NA/Admin Global Port parameter 'banner'.
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { callGenericEntry 12 }
|
|
|
|
callGenericTcpKeepAlive OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The default keep-alive value for connections
|
|
to this serial port. If this is zero, use the
|
|
value specified by anxTcpKeepAlive.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'tcp_keepalive'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { callGenericEntry 13 }
|
|
|
|
callGenericDedicatedArgs OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..100))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Command line arguments passed to process
|
|
started by a dedicated port with mode set
|
|
to 'telnet', 'tn3270', 'rlogin', 'connect'
|
|
(if LAT is in use) or 'call'. This object is
|
|
not valid for TA ports.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'dedicated_arguments'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { callGenericEntry 14 }
|
|
|
|
callGenericModemVar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string defining the type of modem attached
|
|
to the serial port. This object is not valid
|
|
for TA ports. This is always set to
|
|
'microcom'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'type_of_modem'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { callGenericEntry 15 }
|
|
|
|
|
|
callGenericDefSessMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
interactive(1),
|
|
passthru(2),
|
|
passall(3),
|
|
transparent(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The default session mode when the DECServer
|
|
command interface is configured. The default
|
|
is interactive.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'default_session_mode'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { callGenericEntry 16 }
|
|
|
|
callGenericResolveProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
connect(15),
|
|
telnet(17),
|
|
any(19)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Default host protocol to use when starting a
|
|
dedicated port and the protocol is not
|
|
explicitly specified in the command. Is set
|
|
to one of 'telnet', connect, or any. Any
|
|
means to try LAT (connect) first and if that
|
|
fails, try telnet.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'resolve_protocol.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { callGenericEntry 17 }
|
|
|
|
callGenericMaxSession OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of concurrent sessions allowed
|
|
on the port. A value of -1 indicates no maximum.
|
|
Setting the maximum to less than the current
|
|
number of sessions has unspecified results. This MIB
|
|
object corresponds to the NA/Admin parameter
|
|
'max_session_count'."
|
|
::= { callGenericEntry 18 }
|
|
|
|
callGenericSpeed OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..20))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum speed of the port for this call."
|
|
::= { callGenericEntry 19 }
|
|
|
|
callGenericAutoBaud OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is always set to disabled."
|
|
::= { callGenericEntry 20 }
|
|
|
|
callGenericJobs OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..1024))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Job list for this cli session."
|
|
::= { callGenericEntry 21 }
|
|
|
|
callGenericLineType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cli(1),
|
|
slave(2),
|
|
unused3(3),
|
|
unused4(4),
|
|
vcli(5),
|
|
dedicated(6),
|
|
slip(7),
|
|
lpd(8),
|
|
ppp(9),
|
|
mp(10),
|
|
arap(11),
|
|
ftp(12),
|
|
unused13(13),
|
|
unused14(14),
|
|
dynamicdial(15)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is what the port is running at the moment.
|
|
callgenericmode will tell you what the port is
|
|
configured to run through the spb or e2rom."
|
|
::= { callGenericEntry 22 }
|
|
|
|
-- ports flow control and signal parameters.
|
|
|
|
callSignalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallSignalEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries for port flow control and
|
|
signal parameters."
|
|
::= { connections 2 }
|
|
|
|
callSignalEntry OBJECT-TYPE
|
|
SYNTAX CallSignalEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The table of entries of flow control and
|
|
signal parameters for active calls."
|
|
INDEX { callSignalLineIdx, callSignalIdx }
|
|
::= { callSignalTable 1 }
|
|
|
|
CallSignalEntry ::= SEQUENCE {
|
|
callSignalLineIdx INTEGER,
|
|
callSignalIdx INTEGER,
|
|
callSignalInputStartChar DisplayString,
|
|
callSignalInputStopChar DisplayString,
|
|
callSignalOutputStartChar DisplayString,
|
|
callSignalOutputStopChar DisplayString,
|
|
callSignalIxanyFlowCtrl INTEGER,
|
|
callSignalForwardKey DisplayString,
|
|
callSignalBackwardKey DisplayString,
|
|
callSignalCharInFlow INTEGER,
|
|
callSignalCharOutFlow INTEGER,
|
|
callSignalrs232AsyncBits INTEGER,
|
|
callSignalrs232AsyncStopBits INTEGER,
|
|
callSignalrs232AsyncParity INTEGER
|
|
}
|
|
|
|
callSignalLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callSignalEntry 1 }
|
|
|
|
callSignalIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callSignalEntry 2 }
|
|
|
|
-- { callSignalEntry 3 } is reserved
|
|
|
|
callSignalInputStartChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The control character sequence that restarts
|
|
input if the charPortInFlowType parameter
|
|
(in the char MIB) is set to xonXoff.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'input_start_char'.
|
|
|
|
Note: This object is not valid for
|
|
Synchronous ports."
|
|
::= { callSignalEntry 4 }
|
|
|
|
callSignalInputStopChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The control character sequence that stops
|
|
input if the charPortInFlowType parameter
|
|
(in the char MIB) is set to xonXoff.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'input_stop_char'.
|
|
|
|
Note: This object is not valid for
|
|
Synchronous ports."
|
|
::= { callSignalEntry 5 }
|
|
|
|
callSignalOutputStartChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The control character sequence that restarts
|
|
output if the charPortOutFlowType parameter
|
|
(in the char MIB) is set to xonXoff.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'output_start_char'.
|
|
|
|
Note: This object is not valid for
|
|
Synchronous ports."
|
|
::= { callSignalEntry 6 }
|
|
|
|
callSignalOutputStopChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The control character sequence that stops
|
|
output if the charPortOutFlowType parameter
|
|
(in the char MIB) is set to xonXoff.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'output_stop_char'.
|
|
|
|
Note: This object is not valid for
|
|
Synchronous ports."
|
|
::= { callSignalEntry 7 }
|
|
|
|
callSignalIxanyFlowCtrl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies whether any input
|
|
character will be treated as a start (xon)
|
|
character when output has been suspended by
|
|
a stop (xoff) character.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'ixany_flow_control'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { callSignalEntry 8 }
|
|
|
|
-- { callSignalEntry 9 } is reserved
|
|
|
|
callSignalForwardKey OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines a control character sequence as an
|
|
attention character to switch the user to
|
|
the next session. The Annex-II only allows
|
|
a single control character (eg. ^A), while
|
|
the Annex3 and MicroAnnex allow a string
|
|
of control characters to be defined
|
|
(eg. ^A^B^Z).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'forward_key'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { callSignalEntry 10 }
|
|
|
|
callSignalBackwardKey OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines a control character sequence as an
|
|
attention character to switch the user to
|
|
the previous session. The Annex-II only allows
|
|
a single control character (eg. ^A), while
|
|
the Annex3 and MicroAnnex allow a string
|
|
of control characters to be defined
|
|
(eg. ^A^B^Z).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'Backward_key'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { callSignalEntry 11 }
|
|
|
|
|
|
-- { callSignalEntry 12 } is reserved
|
|
|
|
-- { callSignalEntry 13 } is reserved
|
|
|
|
-- { callSignalEntry 14 } is reserved
|
|
|
|
-- { callSignalEntry 15 } is reserved
|
|
|
|
-- { callSignalEntry 16 } is reserved
|
|
|
|
|
|
callSignalCharInFlow OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
eia(2),
|
|
xonXoff(3),
|
|
bell(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's type of input flow control. 'none'
|
|
indicates no flow control at this level or below.
|
|
'xonXoff' indicates software flow control by
|
|
recognizing XON and XOFF characters. 'eia'(hardware)
|
|
indicates flow control delegated to the lower level,
|
|
for example a parallel port."
|
|
::= { callSignalEntry 17 }
|
|
|
|
callSignalCharOutFlow OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
eia(2),
|
|
xonXoff(3),
|
|
bell(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The port's type of output flow control. 'none'
|
|
indicates no flow control at this level or below.
|
|
'xonXoff' indicates software flow control by
|
|
recognizing XON and XOFF characters. 'eia'(hardware)
|
|
indicates flow control delegated to the lower level,
|
|
for example a parallel port."
|
|
::= { callSignalEntry 18 }
|
|
|
|
callSignalrs232AsyncBits OBJECT-TYPE
|
|
SYNTAX INTEGER (5..8)
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The port's number of bits in a character. This object
|
|
corresponds to the admin parameter data_bits."
|
|
::= { callSignalEntry 19 }
|
|
|
|
callSignalrs232AsyncStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
one(1),
|
|
one-and-half(2),
|
|
two(3),
|
|
dynamic(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The port's number of stop bits. This object corresponds
|
|
to the admin parameter stop_bits."
|
|
::= { callSignalEntry 20 }
|
|
|
|
callSignalrs232AsyncParity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
odd(2),
|
|
even(3),
|
|
mark(4),
|
|
space(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The port's sense of a character parity bit."
|
|
::= { callSignalEntry 21 }
|
|
|
|
-- port login parameters.
|
|
|
|
callLoginTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallLoginEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries of login parameters for
|
|
active calls.
|
|
|
|
Note: This table is not valid for Synchronous ports."
|
|
|
|
::= { connections 3 }
|
|
|
|
callLoginEntry OBJECT-TYPE
|
|
SYNTAX CallLoginEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Call's login user parameters."
|
|
INDEX { callLoginLineIdx, callLoginIdx }
|
|
::= { callLoginTable 1 }
|
|
|
|
CallLoginEntry ::= SEQUENCE {
|
|
callLoginLineIdx INTEGER,
|
|
callLoginIdx INTEGER,
|
|
callLoginVciLoginPortPasswd INTEGER,
|
|
callLoginVciLoginTimeout INTEGER
|
|
}
|
|
|
|
callLoginLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callLoginEntry 1 }
|
|
|
|
callLoginIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callLoginEntry 2 }
|
|
|
|
callLoginVciLoginPortPasswd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates if the port is configured as a
|
|
DECServer interface port. The default is
|
|
disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'login_port_password'."
|
|
::= { callLoginEntry 3 }
|
|
|
|
callLoginVciLoginTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enables a login timer if the port is
|
|
configured as a DECServer interface port. The
|
|
default is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'login_timeout'."
|
|
::= { callLoginEntry 4 }
|
|
|
|
|
|
-- port timer and counter parameters
|
|
|
|
callTimerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallTimerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries of port timer and counter
|
|
parameters for active calls.
|
|
Note: This table is not valid for Synchronous ports."
|
|
::= { connections 4 }
|
|
|
|
callTimerEntry OBJECT-TYPE
|
|
SYNTAX CallTimerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Call's timer and counter parameters."
|
|
INDEX { callTimerLineIdx, callTimerIdx }
|
|
::= { callTimerTable 1 }
|
|
|
|
CallTimerEntry ::= SEQUENCE {
|
|
callTimerLineIdx INTEGER,
|
|
callTimerIdx INTEGER,
|
|
callTimerForwardTimer INTEGER,
|
|
callTimerForwardCount INTEGER,
|
|
callTimerCliInactivity INTEGER,
|
|
callTimerCliInactivityTimer INTEGER,
|
|
callTimerInputIsActivity INTEGER,
|
|
callTimerOutputIsActivity INTEGER,
|
|
callTimerResetIdleTimer INTEGER,
|
|
callTimerLongBreak INTEGER,
|
|
callTimerShortBreak INTEGER
|
|
}
|
|
|
|
callTimerLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callTimerEntry 1 }
|
|
|
|
callTimerIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callTimerEntry 2 }
|
|
|
|
callTimerForwardTimer OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the inter-character
|
|
timer that sets the amount of time, in tens of
|
|
milliseconds, that will elapse before
|
|
forwarding the received data. The value of
|
|
5 turns means the timer is off.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'forwarding_timer'."
|
|
::= { callTimerEntry 3 }
|
|
|
|
callTimerForwardCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the number of received characters
|
|
buffered for the port by the Annex before
|
|
forwarding the characters to the host or
|
|
network.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'forwarding_count'."
|
|
::= { callTimerEntry 4 }
|
|
|
|
callTimerCliInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time, in minutes, that the
|
|
Annex waits before hanging up the serial/ta
|
|
port after it becomes idle. A value of 0
|
|
indicates the timer is off. A value of 255
|
|
means immediate, which causes the Annex to
|
|
hang up the port immediately after exiting
|
|
from the last job.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'cli_inactivity'."
|
|
::= { callTimerEntry 5 }
|
|
|
|
callTimerCliInactivityTimer OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time, in minutes, which a port
|
|
can remain inactive before the Annex
|
|
terminates all sessions and resets the port. A
|
|
value of 0 implies timer is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'inactivity_timer'."
|
|
::= { callTimerEntry 6 }
|
|
|
|
callTimerInputIsActivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether received input characters
|
|
are considered as activity for the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'input_is_activity'."
|
|
::= { callTimerEntry 7 }
|
|
|
|
callTimerOutputIsActivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether transmitted output
|
|
characters are considered as activity for the
|
|
port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'output_is_activity'."
|
|
::= { callTimerEntry 8 }
|
|
|
|
|
|
callTimerResetIdleTimer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(1),
|
|
output(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines whether input or output resets the
|
|
idle timer for the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'reset_idle_time_on'."
|
|
::= { callTimerEntry 9 }
|
|
|
|
callTimerLongBreak OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
returns the user to the CLI prompt after
|
|
receiving a break greater than two seconds.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'long_break'."
|
|
::= { callTimerEntry 10 }
|
|
|
|
callTimerShortBreak OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
returns the user to the CLI prompt after
|
|
receiving a break shorter than two seconds.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'short_break'."
|
|
::= { callTimerEntry 11 }
|
|
|
|
|
|
-- security parameters
|
|
|
|
callSecurityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallSecurityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries of port security parameters
|
|
for active calls."
|
|
::= { connections 5 }
|
|
|
|
callSecurityEntry OBJECT-TYPE
|
|
SYNTAX CallSecurityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Call's security parameters."
|
|
INDEX { callSecurityLineIdx, callSecurityIdx }
|
|
::= { callSecurityTable 1 }
|
|
|
|
CallSecurityEntry ::= SEQUENCE {
|
|
callSecurityLineIdx INTEGER,
|
|
callSecurityIdx INTEGER,
|
|
callSecurityUserName DisplayString,
|
|
callSecurityCli INTEGER,
|
|
callSecurityConnect INTEGER,
|
|
callSecurityPortServer INTEGER,
|
|
callSecurityPortPasswd DisplayString,
|
|
callSecurityIpsoClass INTEGER,
|
|
callSecurityIpx INTEGER,
|
|
callSecurityCurrentUser DisplayString
|
|
}
|
|
|
|
callSecurityLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callSecurityEntry 1 }
|
|
|
|
callSecurityIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callSecurityEntry 2 }
|
|
|
|
callSecurityUserName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string defining the default user name for
|
|
the user of this serial/ta port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'user_name'."
|
|
::= { callSecurityEntry 3}
|
|
|
|
callSecurityCli OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether security is
|
|
enabled for the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'cli_security'."
|
|
::= { callSecurityEntry 4 }
|
|
|
|
callSecurityConnect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the
|
|
host-based security policy is enabled for
|
|
access from the port to the network.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'connect_security'."
|
|
::= { callSecurityEntry 5}
|
|
|
|
callSecurityPortServer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the
|
|
host-based security policy is enabled for
|
|
access to the port from the port server.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'port_server_security'."
|
|
::= { callSecurityEntry 6}
|
|
|
|
callSecurityPortPasswd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines a password for the
|
|
port for local password protection.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'port_password'."
|
|
::= { callSecurityEntry 7}
|
|
|
|
callSecurityIpsoClass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
secret(2),
|
|
topsecret(3),
|
|
confidential(4),
|
|
unclassified(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the IP security classification for
|
|
packets sent and received on this port. The
|
|
default value is none.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'ipso_class'."
|
|
::= { callSecurityEntry 8 }
|
|
|
|
callSecurityIpx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether IPX security is enabled on
|
|
this port. The default is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'ipx_security'."
|
|
::= { callSecurityEntry 9 }
|
|
|
|
callSecurityCurrentUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Returns the username for an active call on a
|
|
b channel. This MIB object is only valid if
|
|
security is enabled."
|
|
::= { callSecurityEntry 10 }
|
|
|
|
-- Line editing parameters.
|
|
|
|
callLineEditTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallLineEditEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries of line editing parameters
|
|
for active calls.
|
|
|
|
Note: This table is not valid for
|
|
synchronous ports."
|
|
::= { connections 6 }
|
|
|
|
callLineEditEntry OBJECT-TYPE
|
|
SYNTAX CallLineEditEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Call's line editing parameters."
|
|
INDEX { callLineEditLineIdx, callLineEditIdx }
|
|
::= { callLineEditTable 1 }
|
|
|
|
CallLineEditEntry ::= SEQUENCE {
|
|
callLineEditLineIdx INTEGER,
|
|
callLineEditIdx INTEGER,
|
|
callLineEditAttnChar DisplayString,
|
|
callLineEditEcho INTEGER,
|
|
callLineEditTelnetEscape DisplayString,
|
|
callLineEditTelnetCRLF INTEGER,
|
|
callLineEditMapToLower INTEGER,
|
|
callLineEditMapToUpper INTEGER,
|
|
callLineEditCharErase INTEGER,
|
|
callLineEditEraseChar DisplayString,
|
|
callLineEditLineErase INTEGER,
|
|
callLineEditEraseLine DisplayString,
|
|
callLineEditEraseWord DisplayString,
|
|
callLineEditHardwareTabs INTEGER,
|
|
callLineEditRedisplayLine DisplayString,
|
|
callLineEditToggleOutput DisplayString,
|
|
callLineEditNewLineTerm INTEGER
|
|
}
|
|
|
|
callLineEditLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callLineEditEntry 1 }
|
|
|
|
callLineEditIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callLineEditEntry 2 }
|
|
|
|
|
|
callLineEditAttnChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines a control character sequence as an
|
|
attention character to return the user to
|
|
the CLI prompt. The Annex-II only allows
|
|
a single control character (eg. ^A), while
|
|
the Annex3 and MicroAnnex allow a string
|
|
of control characters to be defined
|
|
(eg. ^A^B^Z).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'attn_string'."
|
|
::= { callLineEditEntry 3 }
|
|
|
|
callLineEditEcho OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
echoes all characters as they are received
|
|
from the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'echo'."
|
|
::= { callLineEditEntry 4 }
|
|
|
|
callLineEditTelnetEscape OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the control character that returns
|
|
the user to the 'telnet:' prompt when running
|
|
the CLI telnet command.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
The value 'U' means this feature is disabled
|
|
on this port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'telnet_escape'."
|
|
::= { callLineEditEntry 5 }
|
|
|
|
callLineEditTelnetCRLF OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines what characters are transmitted
|
|
out the port to the network when the
|
|
End-of-Line character is sensed. 'enabled'
|
|
means transmit Line-Feed and Carriage-Return.
|
|
'disabled' means transmit Carriage-Return
|
|
and NULL. The default is enabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'telnet_crlf'."
|
|
::= { callLineEditEntry 6 }
|
|
|
|
|
|
callLineEditMapToLower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex translates all upper
|
|
case characters to lower case as they are
|
|
received from the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'map_to_lower'."
|
|
::= { callLineEditEntry 7 }
|
|
|
|
callLineEditMapToUpper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex translates all lower
|
|
case characters to upper case as they are
|
|
transmitted to the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter '
|
|
map_to_upper'."
|
|
::= { callLineEditEntry 8 }
|
|
|
|
callLineEditCharErase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
echoes the character erase and word erase
|
|
characters for a video terminal (enabled)
|
|
or for a hard-copy terminal (disabled).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'char_erase'."
|
|
::= { callLineEditEntry 9 }
|
|
|
|
callLineEditEraseChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the character erase control character
|
|
sequence.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'erase_char'."
|
|
::= { callLineEditEntry 10 }
|
|
|
|
callLineEditLineErase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
echoes the line erase character for a video
|
|
terminal (enabled) or for a hard-copy terminal
|
|
(disabled).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'line_erase'."
|
|
::= { callLineEditEntry 11 }
|
|
|
|
callLineEditEraseLine OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the line erase control character
|
|
sequence.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'erase_line'."
|
|
::= { callLineEditEntry 12 }
|
|
|
|
callLineEditEraseWord OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the word erase control character
|
|
sequence.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'erase_word'."
|
|
::= { callLineEditEntry 13 }
|
|
|
|
callLineEditHardwareTabs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, this parameter allows the Annex
|
|
to expand ASCII tab characters.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'hardware_tabs'."
|
|
::= { callLineEditEntry 14 }
|
|
|
|
|
|
callLineEditRedisplayLine OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the reprint line control character
|
|
sequence.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'redisplay_line'."
|
|
::= { callLineEditEntry 15 }
|
|
|
|
callLineEditToggleOutput OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the flush control character used to
|
|
flush the output buffer.
|
|
|
|
This value of this object can be either a
|
|
single displayable character or two characters
|
|
of the form '^x', where '^x' is translated as
|
|
'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'toggle_output'."
|
|
::= { callLineEditEntry 16 }
|
|
|
|
callLineEditNewLineTerm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether a carriage
|
|
return is echoed as just a carriage return
|
|
(enabled), or whether the carriage return is
|
|
echoed as a carriage return and line feed.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'newline_terminal'."
|
|
::= { callLineEditEntry 17 }
|
|
|
|
|
|
-- Networking Protocol parameters.
|
|
|
|
callNetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallNetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries of networking protocol
|
|
parameters for active calls."
|
|
::= { connections 7 }
|
|
|
|
callNetEntry OBJECT-TYPE
|
|
SYNTAX CallNetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Call's networking protocol parameters."
|
|
INDEX { callNetLineIdx, callNetIdx }
|
|
::= { callNetTable 1 }
|
|
|
|
CallNetEntry ::= SEQUENCE {
|
|
callNetLineIdx INTEGER,
|
|
callNetIdx INTEGER,
|
|
callNetLocalAddr IpAddress,
|
|
callNetRemoteAddr IpAddress,
|
|
callNetMetric INTEGER,
|
|
callNetSlipSecure INTEGER,
|
|
callNetInactivity INTEGER,
|
|
callNetDoCompression INTEGER,
|
|
callNetAllowCompression INTEGER,
|
|
callNetInactivityUnits INTEGER
|
|
}
|
|
|
|
callNetLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callNetEntry 1 }
|
|
|
|
callNetIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callNetEntry 2 }
|
|
|
|
callNetLocalAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Internet address for the Annex's side
|
|
of the point-to-point (SLIP or PPP) link.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'local_address'."
|
|
::= { callNetEntry 3 }
|
|
|
|
callNetRemoteAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Internet address for the host at the
|
|
remote end of the point-to-point (SLIP or PPP)
|
|
link.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'remote_address'."
|
|
::= { callNetEntry 4 }
|
|
|
|
-- ::= { callNetEntry 5 } removed object
|
|
|
|
callNetMetric OBJECT-TYPE
|
|
SYNTAX INTEGER (0..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the hop count to
|
|
the remote end of the SLIP or PPP interface.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta. synchronous port parameter
|
|
'metric'."
|
|
::= { callNetEntry 6 }
|
|
|
|
callNetSlipSecure OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If anxEnableSecurity is disabled, this
|
|
parameter selects slip session logging. If
|
|
anxEnableSecurity is enabled, this parameter
|
|
permits slip access only from secure ports.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter
|
|
'slip_ppp_security'.
|
|
|
|
Note: This object is not valid for
|
|
Synchronous ports."
|
|
::= { callNetEntry 7 }
|
|
|
|
callNetInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of units allowed for serial
|
|
protocol inactivity on the port. The type of
|
|
unit, minutes or seconds, is defined by the
|
|
object anxpNetInactivityUnits. If the type of
|
|
units is 'seconds', the actual granularity is
|
|
only 5 seconds. When the interval expires,
|
|
the port is automatically reset. A value of 0
|
|
means the timer is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'net_inactivity'."
|
|
::= { callNetEntry 8 }
|
|
|
|
callNetDoCompression OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex will attempt to
|
|
negotiate TCP/IP header compression on this
|
|
serial link.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter
|
|
'do_compression'."
|
|
::= { callNetEntry 9 }
|
|
|
|
callNetAllowCompression OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex will allow TCP/IP
|
|
header compression on this serial link only
|
|
if the other end of the serial link initiates
|
|
the compression.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'allow_compression'."
|
|
::= { callNetEntry 10 }
|
|
|
|
callNetInactivityUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minutes(1),
|
|
seconds(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of units that are used for the
|
|
port's net inactivity timer. See also the
|
|
anxpNetInactivity object. The default value
|
|
is 'minutes'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'net_inactivity_units'."
|
|
::= { callNetEntry 11 }
|
|
|
|
|
|
-- Slip parameters.
|
|
|
|
callSlipTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallSlipEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries of Slip parameters for
|
|
active calls.
|
|
|
|
Note: This object is not valid for
|
|
Synchronous ports."
|
|
::= { connections 8 }
|
|
|
|
callSlipEntry OBJECT-TYPE
|
|
SYNTAX CallSlipEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Call's Slip parameters."
|
|
INDEX { callSlipIdx }
|
|
::= { callSlipTable 1 }
|
|
|
|
CallSlipEntry ::= SEQUENCE {
|
|
callSlipLineIdx INTEGER,
|
|
callSlipIdx INTEGER,
|
|
callSlipSubnetMask IpAddress,
|
|
callSlipMtuSize INTEGER,
|
|
callSlipNoIcmp INTEGER,
|
|
callSlipTos INTEGER
|
|
}
|
|
|
|
callSlipLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callSlipEntry 1 }
|
|
|
|
callSlipIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callSlipEntry 2 }
|
|
|
|
callSlipSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subnet mask for this SLIP interface.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'subnet_mask'."
|
|
::= { callSlipEntry 3 }
|
|
|
|
callSlipMtuSize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
large(1),
|
|
small(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Force the compressed SLIP interface to use
|
|
a Maximum Transmission Unit (MTU) of either
|
|
1024 bytes (large) or 256 bytes (small). The
|
|
default is large.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'slip_mtu_size'."
|
|
::= { callSlipEntry 4 }
|
|
|
|
callSlipNoIcmp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex will discard any
|
|
ICMP packets directed to this SLIP link.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'slip_no_icmp'."
|
|
::= { callSlipEntry 5 }
|
|
|
|
callSlipTos OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex sends interactive
|
|
traffic over this SLIP link before any other
|
|
traffic.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'slip_tos'."
|
|
::= { callSlipEntry 6 }
|
|
|
|
|
|
-- PPP parameters
|
|
|
|
callPPPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallPPPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of entries of PPP parameters for
|
|
active calls."
|
|
::= { connections 9 }
|
|
|
|
callPPPEntry OBJECT-TYPE
|
|
SYNTAX CallPPPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Call's PPP parameters."
|
|
INDEX { callPPPLineIdx, callPPPIdx }
|
|
::= { callPPPTable 1 }
|
|
|
|
CallPPPEntry ::= SEQUENCE {
|
|
callPPPLineIdx INTEGER,
|
|
callPPPIdx INTEGER,
|
|
callPPPMru INTEGER,
|
|
callPPPAcm DisplayString,
|
|
callPPPSecurityProto INTEGER,
|
|
callPPPRemoteUser DisplayString,
|
|
callPPPRemotePasswd DisplayString,
|
|
callPPPNcp INTEGER,
|
|
callPPPIpxNetwork DisplayString,
|
|
callPPPIpxNode DisplayString,
|
|
callPPPTraceLevel INTEGER
|
|
}
|
|
|
|
callPPPLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callPPPEntry 1 }
|
|
|
|
callPPPIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callPPPEntry 2 }
|
|
|
|
callPPPMru OBJECT-TYPE
|
|
SYNTAX INTEGER (64..1500)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the maximum receive
|
|
unit in bytes. The default value is 1500.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, and synchronous port
|
|
parameter 'ppp_mru'."
|
|
::= { callPPPEntry 3 }
|
|
|
|
callPPPAcm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (8..10))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies which of the first
|
|
32 bytes (0x00, ... 0x1F) can be sent as
|
|
clear text and which need to be escaped. A
|
|
bit on in the mask indicates the character
|
|
must be escaped. The mask should be specified
|
|
as an 8 hex character string (0x1F000000 and
|
|
1F000000 are both acceptable).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'ppp_acm'."
|
|
::= { callPPPEntry 4 }
|
|
|
|
callPPPSecurityProto OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
pap(2),
|
|
chap(3),
|
|
chap-pap(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines which security protocol will be used
|
|
to authenticate the remote user. This
|
|
parameter must be set and the Annex
|
|
enable_security (anxEnableSecurity) must be
|
|
enabled before authentication is performed.
|
|
The default is none
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter
|
|
'ppp_security_protocol'."
|
|
::= { callPPPEntry 5 }
|
|
|
|
callPPPRemoteUser OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The username used by the Annex to identify
|
|
itself if the remote PPP peer asks for
|
|
authentication.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter
|
|
'ppp_username_remote'."
|
|
::= { callPPPEntry 6 }
|
|
|
|
callPPPRemotePasswd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The password used by the Annex to identify
|
|
itself if the remote PPP peer asks for
|
|
authentication. Reading this parameter
|
|
will return either <set> if the password is
|
|
defined or <unset> if the password is not
|
|
defined.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter
|
|
'ppp_password_remote'."
|
|
::= { callPPPEntry 7 }
|
|
|
|
callPPPNcp OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A bitmask for PPP NCP Options:
|
|
0x0002 NCP_IPCP
|
|
0x0004 NCP_ATCP
|
|
0x0008 NCP_IPXCP
|
|
0x0010 NCP_MP
|
|
0x0020 NCP_CCP
|
|
0x0040 NCP_CBCP
|
|
|
|
Note: if the ncp_option parameter
|
|
is set to the value of 'all', the SNMP
|
|
agent will return the fully expanded bitmask
|
|
value instead of the 0x0001 value of 'all'.
|
|
"
|
|
::= { callPPPEntry 8 }
|
|
|
|
callPPPIpxNetwork OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX network number for an IPX PPP
|
|
connection using this port. When the IPX PPP
|
|
connection is established the network number
|
|
will be negotiated. If one end of the
|
|
connection is set to zero then the value from
|
|
the other end of the connection will be used.
|
|
The value of this object is an 8 digit
|
|
hexadecimal number string representing the
|
|
IPX network segment assigned to this port.
|
|
The value must be unique across the network
|
|
domain.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'ppp_ipx_network'."
|
|
::= { callPPPEntry 9 }
|
|
|
|
callPPPIpxNode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(11..17))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX node number for an IPX PPP connection
|
|
using this port.
|
|
The value of this object is a 12 digit
|
|
hexadecimal number string representing the IPX
|
|
node number assigned to this port.
|
|
Note the string is expected in the form:
|
|
12-3a-4-7-89-23.Each part of the address
|
|
must be a hex value separated by a hyphen.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'ppp_ipx_node'."
|
|
::= { callPPPEntry 10 }
|
|
|
|
callPPPTraceLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
control(1),
|
|
data(2),
|
|
control-and-data(3),
|
|
unused(4),
|
|
control-in-hex(5),
|
|
data-in-hex(6),
|
|
control-and-data-in-hex(7),
|
|
none(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" Controls whether PPP trace messages are sent to the
|
|
syslog facility or not. The default value is none(0).
|
|
This MIB object corresponds to the na/admin port parameter
|
|
ppp_trace_level."
|
|
::= { callPPPEntry 11 }
|
|
|
|
-- ARAP parameters
|
|
|
|
callARAPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallARAPEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of entries of Apple Talk parameters for
|
|
active calls.
|
|
Note: This object is not valid for
|
|
Synchronous ports."
|
|
::= { connections 10 }
|
|
|
|
callARAPEntry OBJECT-TYPE
|
|
SYNTAX CallARAPEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Call's ARAP parameters."
|
|
INDEX {callARAPLineIdx, callARAPIdx }
|
|
::= { callARAPTable 1 }
|
|
|
|
CallARAPEntry ::= SEQUENCE {
|
|
callARAPLineIdx INTEGER,
|
|
callARAPIdx INTEGER,
|
|
callARAPGuest INTEGER,
|
|
callARAPNodeId DisplayString,
|
|
callARAPSecurity INTEGER,
|
|
callARAPV42BIS INTEGER
|
|
}
|
|
|
|
callARAPLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callARAPEntry 1 }
|
|
|
|
callARAPIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callARAPEntry 2 }
|
|
|
|
callARAPGuest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"If enabled, allows ARAP guest login service.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'at_guest'."
|
|
::= { callARAPEntry 3 }
|
|
|
|
callARAPNodeId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (3..11))
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The default AppleTalk node ID hint that is
|
|
used by the Annex on this port. The address
|
|
consists of two parts separated by a dot. The
|
|
address may be in either hex or decimal
|
|
format. The first part is the network address
|
|
and ranges from 0 to 65534 (0x0000 to 0xFFFE).
|
|
The second part is the node address and ranges
|
|
from 0 to 254 (0x00 to 0xFE).
|
|
|
|
Example:
|
|
0x00BF.0xFD 191.253 0x00BF.253 191.0xFD
|
|
are all the same address.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'at_nodeid'."
|
|
::= { callARAPEntry 4 }
|
|
|
|
callARAPSecurity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Controls whether ACP service is enabled for
|
|
this port when establishing an AppleTalk
|
|
connection.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'at_security'."
|
|
::= { callARAPEntry 5 }
|
|
|
|
callARAPV42BIS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Controls whether V.42bis compression is done
|
|
during an ARAP session.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'arap_v42bis'."
|
|
::= { callARAPEntry 6 }
|
|
|
|
|
|
-- TN3270 parameters
|
|
|
|
callTN3270Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallTN3270Entry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of entries of TN3270 parameters for
|
|
active calls.
|
|
|
|
Note:This object is not valid for
|
|
Synchronous ports."
|
|
::= { connections 11 }
|
|
|
|
callTN3270Entry OBJECT-TYPE
|
|
SYNTAX CallTN3270Entry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Call's TN3270 parameters."
|
|
INDEX { callTN3270LineIdx, callTN3270Idx }
|
|
::= { callTN3270Table 1 }
|
|
|
|
CallTN3270Entry ::= SEQUENCE {
|
|
callTN3270LineIdx INTEGER,
|
|
callTN3270Idx INTEGER,
|
|
callTN3270PrinterHost IpAddress,
|
|
callTN3270PrinterName DisplayString
|
|
}
|
|
|
|
callTN3270LineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callTN3270Entry 1 }
|
|
|
|
callTN3270Idx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callTN3270Entry 2 }
|
|
|
|
callTN3270PrinterHost OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The IP address of the machine running a
|
|
Berkeley-style lpd server.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'tn3270_printer_name'."
|
|
::= { callTN3270Entry 3 }
|
|
|
|
callTN3270PrinterName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A valid printer name contained in the
|
|
/etc/printcap file on the remote host.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'tn3270_printer_name'."
|
|
::= { callTN3270Entry 4 }
|
|
|
|
-- Port LAT parameters
|
|
|
|
callLATTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallLATEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of entries of LAT parameters for
|
|
active calls.
|
|
|
|
Note:This object is not valid for
|
|
synchronous ports."
|
|
::= { connections 12 }
|
|
|
|
callLATEntry OBJECT-TYPE
|
|
SYNTAX CallLATEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Call's LAT parameters."
|
|
INDEX { callLATLineIdx, callLATIdx }
|
|
::= { callLATTable 1 }
|
|
|
|
CallLATEntry ::= SEQUENCE {
|
|
callLATLineIdx INTEGER,
|
|
callLATIdx INTEGER,
|
|
callLATAuthMap OCTET STRING,
|
|
callLATbEnable INTEGER,
|
|
callLATMultiSession INTEGER
|
|
}
|
|
|
|
callLATLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callLATEntry 1 }
|
|
|
|
callLATIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callLATEntry 2 }
|
|
|
|
callLATAuthMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..32))
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The syntax of this object is an octet string
|
|
32 bytes long, with the first byte
|
|
representing groups 0 through 7 and the last
|
|
byte representing groups 248 through 255.
|
|
|
|
For example, 0x40 0x25 ... means the groups
|
|
1,10,13,15 are valid for this port.
|
|
A returned value with all bits set to zero is
|
|
the same as setting 'group_value' to 'none'.
|
|
The object always returns a string 32 bytes
|
|
long.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'group_value'."
|
|
::= { callLATEntry 3 }
|
|
|
|
callLATbEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Controls interpretation of LAT Data-B packets
|
|
received from host.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'latb_enable'."
|
|
::= { callLATEntry 4 }
|
|
|
|
callLATMultiSession OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This parameter allows multisession operation
|
|
to be managed on a per port basis. If
|
|
multisessions for the server has not been
|
|
enabled, any attempt to use this command will
|
|
cause the error message
|
|
'ETSMIN-786-Multisession feature Disabled'
|
|
to be displayed.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
port parameter 'multisessions'.
|
|
|
|
Note:
|
|
* SNMP will not check for the Annex
|
|
MultiSession parameter.
|
|
* Setting this MIB object is equivalent to
|
|
defining the port parameter 'multisession'
|
|
through NA/admin."
|
|
::= { callLATEntry 5 }
|
|
|
|
|
|
-- Call SETUP information parameters
|
|
|
|
callSetupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CallSetupEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of entries of call setup information
|
|
active calls."
|
|
::= { connections 13 }
|
|
|
|
callSetupEntry OBJECT-TYPE
|
|
SYNTAX CallSetupEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Call's Setup information parameters."
|
|
INDEX { callSetupLineIdx, callSetupIdx }
|
|
::= { callSetupTable 1 }
|
|
|
|
CallSetupEntry ::= SEQUENCE {
|
|
callSetupLineIdx INTEGER,
|
|
callSetupIdx INTEGER,
|
|
callSetupPortType INTEGER,
|
|
callSetupCallType INTEGER,
|
|
callSetupCallingTime INTEGER,
|
|
callSetupCallingNbr DisplayString,
|
|
callSetupCalledNbr DisplayString,
|
|
callSetupCalledSubAddr DisplayString,
|
|
callSetupBearer INTEGER,
|
|
callSetupPortNumber INTEGER
|
|
}
|
|
|
|
callSetupLineIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change '7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213).
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { callSetupEntry 1 }
|
|
|
|
callSetupIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..30)
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A call's B channel number ranging from 1-30."
|
|
::= { callSetupEntry 2 }
|
|
|
|
callSetupPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
async(1),
|
|
sync(2),
|
|
ta(3),
|
|
detecting(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A enumerated integer indicating the port
|
|
type. Detecting(4) means the annex is in the
|
|
process of detecting the port type."
|
|
::= { callSetupEntry 3 }
|
|
|
|
callSetupCallType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incoming(1),
|
|
outgoing(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object returns the whether the call is
|
|
incoming or outgoing."
|
|
::= { callSetupEntry 4 }
|
|
|
|
callSetupCallingTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object returns the time the call has been
|
|
in progress. Measured in seconds"
|
|
::= { callSetupEntry 5 }
|
|
|
|
callSetupCallingNbr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object returns the calling number."
|
|
::= { callSetupEntry 6 }
|
|
|
|
callSetupCalledNbr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object returns the number called."
|
|
::= { callSetupEntry 7 }
|
|
|
|
callSetupCalledSubAddr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object returns called party subaddress."
|
|
::= { callSetupEntry 8 }
|
|
|
|
callSetupBearer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
data(1),
|
|
voice(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object defines the bearer capability
|
|
of the incoing call. Possible values are
|
|
voice and data."
|
|
::= { callSetupEntry 9 }
|
|
|
|
callSetupPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object returns the port number the call
|
|
is assigned to. This object in conjunction with the
|
|
object, port type, should be used to cross-reference
|
|
the information displayed by the CLI command 'who'."
|
|
::= { callSetupEntry 10 }
|
|
|
|
|
|
|
|
-- PRI Global parameters.
|
|
|
|
gpGenericMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cli(1),
|
|
slave(2),
|
|
adaptive(3),
|
|
unused(4),
|
|
slip(5),
|
|
ppp(7),
|
|
auto-detect(10),
|
|
auto-adapt(11),
|
|
rlogin(16),
|
|
telnet(17)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the mode for access
|
|
to the serial line or TA port.
|
|
The default is cli.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous,ta, synchronous port parameter
|
|
'mode'.
|
|
|
|
Note: Values 6, 8, 9, 12, 13, 14, 15, and 18
|
|
cannot be set."
|
|
::= { globals 1 }
|
|
|
|
gpGenericLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive string for a this port. This
|
|
string is displayed by the CLI who command.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'location'."
|
|
::= { globals 2 }
|
|
|
|
gpGenericTermVar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string defining the type of terminal
|
|
attached to the serial/ta port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'term_var'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { globals 3 }
|
|
|
|
gpGenericPrompt OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines a port-specific prompt
|
|
string. The prompt string consists of displayable
|
|
characters and embedded formatting codes. Each
|
|
formatting code is stored in a single character
|
|
in nonvolatile memory. The maximum number of
|
|
characters stored for the prompt string
|
|
is 16. Since the formatting codes consist of
|
|
a '%' prepended to a single character, the maximum
|
|
length string that may be entered for this object
|
|
is 32 characters. Strings less than 32
|
|
characters in length will be rejected as bad values
|
|
if they cannot be stored into 16 characters in
|
|
nonvolatile memory after the formatting codes are
|
|
compressed into single characters.
|
|
|
|
The valid formatting codes are:
|
|
|
|
%a the string 'annex'
|
|
%c the string ': '
|
|
%d the date and time
|
|
%i the Annex's IP address
|
|
%j a newline character
|
|
%l port location, or 'port n'
|
|
%n the Annex's name
|
|
%p the port number
|
|
%r the string 'port'
|
|
%s a space
|
|
%t the time hh:mm:ss
|
|
%u the user name for port
|
|
%% the string '%'
|
|
|
|
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'prompt'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { globals 4 }
|
|
|
|
|
|
gpGenericCliInterface OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uci(1),
|
|
vci(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specifies either a Unix or VMS command line
|
|
interface. The default is uci.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'cli_interface'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { globals 5 }
|
|
|
|
gpGenericAllowBcast OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether the serial/ta port can
|
|
receive administrative broadcast messages.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter
|
|
'allow_broadcast'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { globals 6 }
|
|
|
|
gpGenericBcastDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
port(1),
|
|
network(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the direction that an administrative
|
|
broadcast message is sent. This parameter is
|
|
valid only when the port is defined as a slave
|
|
port by the anxpMode parameter.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'broadcast_direction'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { globals 7 }
|
|
|
|
gpGenericImask7Bits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, instructs the Annex to ignore
|
|
the eighth bit of all received characters
|
|
on the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'imask_7bits'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { globals 8 }
|
|
|
|
gpGenericCliImask7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines whether input at the CLI is masked to
|
|
7 bits. The default is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'cli_imask7'. The
|
|
default value for this object is enabled.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { globals 9 }
|
|
|
|
|
|
gpGenericBanner OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
beforesec(3),
|
|
aftersec(4),
|
|
motd-before-sec(5),
|
|
motd-after-sec(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies whether the Annex banner and message-
|
|
of-the-day are displayed on the port. The
|
|
default is enabled.
|
|
This has four possible actions:
|
|
|
|
default, Y, yes, unset: banner before security,
|
|
motd after
|
|
none, N: no banner or motd
|
|
beforesec: banner and motd before
|
|
security
|
|
aftersec: banner and motd after
|
|
security
|
|
motd-before-sec: motd before security; no
|
|
banner
|
|
motd-after-sec: motd after security; no
|
|
banner
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous port parameter 'banner'.
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { globals 10 }
|
|
|
|
gpGenericTcpKeepAlive OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The default keep-alive value for connections
|
|
to this serial port. If this is zero, use the
|
|
value specified by anxTcpKeepAlive.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'tcp_keepalive'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { globals 11 }
|
|
|
|
gpGenericDedicatedArgs OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..100))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Command line arguments to be passed to process
|
|
started by a dedicated port with mode set to
|
|
'telnet', 'tn3270', 'rlogin', 'connect' (if LAT
|
|
is in use) or 'call'.
|
|
This object is not valid for TA ports.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'dedicated_arguments'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { globals 12 }
|
|
|
|
gpGenericModemVar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string defining the type of modem attached
|
|
to the serial port.
|
|
This object is not valid for TA ports.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'type_of_modem'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { globals 13 }
|
|
|
|
|
|
gpGenericDefSessMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
interactive(1),
|
|
passthru(2),
|
|
passall(3),
|
|
transparent(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The default session mode when the DECServer command
|
|
interface is configured. The default is interactive.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'default_session_mode'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { globals 14 }
|
|
|
|
gpGenericResolveProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
connect(15),
|
|
telnet(17),
|
|
any(19)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Default host protocol to use when starting a
|
|
dedicated port and the protocol is not explicitly
|
|
specified in the command. Is set to one of
|
|
'telnet', connect, or any. Any means to try LAT
|
|
(connect) first and if that fails, try telnet.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'resolve_protocol.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
|
|
::= { globals 15 }
|
|
|
|
|
|
-- ports flow control and signal parameters.
|
|
|
|
-- { globals 16 } is reserved
|
|
|
|
gpSignalInputStartChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The control character sequence that restarts
|
|
input if the charPortInFlowType parameter
|
|
(in the char MIB) is set to xonXoff.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'input_start_char'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { globals 17 }
|
|
|
|
gpSignalInputStopChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The control character sequence that stops
|
|
input if the charPortInFlowType parameter
|
|
(in the char MIB) is set to xonXoff.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'input_stop_char'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { globals 18 }
|
|
|
|
gpSignalOutputStartChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The control character sequence that restarts
|
|
output if the charPortOutFlowType parameter
|
|
(in the char MIB) is set to xonXoff.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'output_start_char'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
|
|
::= { globals 19 }
|
|
|
|
gpSignalOutputStopChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The control character sequence that stops
|
|
output if the charPortOutFlowType parameter
|
|
(in the char MIB) is set to xonXoff.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'output_stop_char'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { globals 20 }
|
|
|
|
gpSignalIxanyFlowCtrl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies whether any input
|
|
character will be treated as a start (xon)
|
|
character when output has been suspended by
|
|
a stop (xoff) character.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'ixany_flow_control'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
|
|
::= { globals 21 }
|
|
|
|
-- { globals 22 } is reserved
|
|
|
|
gpSignalForwardKey OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines a control character sequence as an
|
|
attention character to switch the user to
|
|
the next session. The Annex-II only allows
|
|
a single control character (eg. ^A), while
|
|
the Annex3 and MicroAnnex allow a string
|
|
of control characters to be defined
|
|
(eg. ^A^B^Z).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'forward_key'.
|
|
|
|
Note: This object is not valid for
|
|
synchronous ports."
|
|
::= { globals 23 }
|
|
|
|
gpSignalBackwardKey OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines a control character sequence as an
|
|
attention character to switch the user to
|
|
the previous session. The Annex-II only allows
|
|
a single control character (eg. ^A), while
|
|
the Annex3 and MicroAnnex allow a string
|
|
of control characters to be defined
|
|
(eg. ^A^B^Z).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'Backward_key'.
|
|
|
|
Note: This object is not valid for Synchronous ports."
|
|
::= { globals 24 }
|
|
|
|
-- { globals 25 } is reserved
|
|
|
|
-- { globals 26 } is reserved
|
|
|
|
-- { globals 27 } is reserved
|
|
|
|
-- { globals 28 } is reserved
|
|
|
|
-- { globals 29 } is reserved
|
|
|
|
-- port login parameters.
|
|
|
|
gpLoginVciLoginPortPasswd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enables the port password if the port is
|
|
configured as a DECServer interface port.
|
|
The default is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'login_port_password'."
|
|
|
|
::= { globals 30 }
|
|
|
|
gpLoginVciLoginTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enables a login timer if the port is configured
|
|
as a DECServer interface port. The default
|
|
is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'login_timeout'."
|
|
|
|
::= { globals 31 }
|
|
|
|
|
|
-- port timer and counter parameters
|
|
|
|
gpTimerForwardTimer OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the inter-character
|
|
timer that sets the amount of time, in tens of
|
|
milliseconds, that will elapse before
|
|
forwarding the received data. The value of
|
|
5 turns off the timer. Setting this object
|
|
to 0 causes the default value of 5 to be used.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'forwarding_timer'."
|
|
::= { globals 32 }
|
|
|
|
gpTimerForwardCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the number of received characters
|
|
buffered for the port by the Annex before
|
|
forwarding the characters to the host or
|
|
network.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'forwarding_count'."
|
|
::= { globals 33 }
|
|
|
|
gpTimerCliInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time, in minutes, that the Annex
|
|
waits before hanging up the serial/ta port after
|
|
it becomes idle. A value of 0 turns off the
|
|
timer. A value of 255 means immediate, which
|
|
causes the Annex to hang up the port immediately
|
|
after exiting from the last job.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'cli_inactivity'."
|
|
|
|
::= { globals 34 }
|
|
|
|
gpTimerInactivityTimer OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time, in minutes, which a port
|
|
can remain inactive before the Annex terminates
|
|
all sessions and resets the port. A value of
|
|
0 disables the timer.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'inactivity_timer'."
|
|
::= { globals 35 }
|
|
|
|
gpTimerInputIsActivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether received input characters
|
|
are considered as activity for the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'input_is_activity'."
|
|
::= { globals 36 }
|
|
|
|
gpTimerOutputIsActivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether transmitted output characters
|
|
are considered as activity for the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'output_is_activity'."
|
|
::= { globals 37 }
|
|
|
|
|
|
gpTimerResetIdleTimer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(1),
|
|
output(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines whether input or output resets the
|
|
idle timer for the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'reset_idle_time_on'."
|
|
|
|
::= { globals 38 }
|
|
|
|
gpTimerLongBreak OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
returns the user to the CLI prompt after
|
|
receiving a break greater than two seconds.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'long_break'."
|
|
|
|
::= { globals 39 }
|
|
|
|
gpTimerShortBreak OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
returns the user to the CLI prompt after
|
|
receiving a break shorter than two seconds.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'short_break'."
|
|
::= { globals 40 }
|
|
|
|
|
|
-- security parameters
|
|
|
|
gpSecurityUserName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string defining the default user name for
|
|
the user of this serial/ta port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'user_name'."
|
|
::= { globals 41 }
|
|
|
|
gpSecurityCli OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether security is
|
|
enabled for the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'cli_security'."
|
|
::= { globals 42 }
|
|
|
|
gpSecurityConnect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the host-based
|
|
security policy is enabled for access from the
|
|
port to the network.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'connect_security'."
|
|
::= { globals 43 }
|
|
|
|
gpSecurityPortServer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the host-based
|
|
security policy is enabled for access to the
|
|
port from the port server.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'port_server_security'."
|
|
::= { globals 44 }
|
|
|
|
gpSecurityPortPasswd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines a password for the
|
|
port for local password protection.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'port_password'."
|
|
::= { globals 45 }
|
|
|
|
gpSecurityIpsoClass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
secret(2),
|
|
topsecret(3),
|
|
confidential(4),
|
|
unclassified(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the IP security classification for
|
|
packets sent and received on this port. The
|
|
default value is none.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'ipso_class'."
|
|
::= { globals 46 }
|
|
|
|
gpSecurityIpx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether IPX security is enabled on
|
|
this port. The default is disabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'ipx_security'."
|
|
::= { globals 47 }
|
|
|
|
|
|
-- Line editing parameters.
|
|
|
|
gpLineEditAttnChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines a control character sequence as an
|
|
attention character to return the user to
|
|
the CLI prompt. The Annex-II only allows
|
|
x a single control character (eg. ^A), while
|
|
the Annex3 and MicroAnnex allow a string
|
|
of control characters to be defined
|
|
(eg. ^A^B^Z).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'attn_string'."
|
|
::= { globals 48 }
|
|
|
|
|
|
gpLineEditEcho OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
echoes all characters as they are received
|
|
from the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'echo'."
|
|
::= { globals 49 }
|
|
|
|
gpLineEditTelnetEscape OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the control character that returns the
|
|
user to the 'telnet:' prompt when running the
|
|
CLI telnet command.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
The value 'U' disables this feature on the
|
|
specified port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'telnet_escape'."
|
|
::= { globals 50 }
|
|
|
|
gpLineEditTelnetCRLF OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines what characters are transmitted
|
|
out the port to the network when the
|
|
End-of-Line character is sensed. 'enabled'
|
|
means transmit Line-Feed and Carriage-Return.
|
|
'disabled' means transmit Carriage-Return
|
|
and NULL. The default is enabled.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'telnet_crlf'."
|
|
::= { globals 51 }
|
|
|
|
|
|
gpLineEditMapToLower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex translates all upper
|
|
case characters to lower case as they are
|
|
received from the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'map_to_lower'."
|
|
::= { globals 52 }
|
|
|
|
gpLineEditMapToUpper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex translates all lower
|
|
case characters to upper case as they are
|
|
transmitted to the port.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'map_to_upper'."
|
|
::= { globals 53 }
|
|
|
|
gpLineEditCharErase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
echoes the character erase and word erase
|
|
characters for a video terminal (enabled)
|
|
or for a hard-copy terminal (disabled).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'char_erase'."
|
|
::= { globals 54 }
|
|
|
|
gpLineEditEraseChar OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the character erase control character
|
|
sequence.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'erase_char'."
|
|
::= { globals 55 }
|
|
|
|
gpLineEditLineErase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether the Annex
|
|
echoes the line erase character for a video
|
|
terminal (enabled) or for a hard-copy terminal
|
|
(disabled).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'line_erase'."
|
|
::= { globals 56 }
|
|
|
|
gpLineEditEraseLine OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the line erase control character
|
|
sequence.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'erase_line'."
|
|
::= { globals 57 }
|
|
|
|
gpLineEditEraseWord OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the word erase control character
|
|
sequence.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'erase_word'."
|
|
::= { globals 58 }
|
|
|
|
gpLineEditHardwareTabs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, this parameter allows the Annex
|
|
to expand ASCII tab characters.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'hardware_tabs'."
|
|
::= { globals 59 }
|
|
|
|
|
|
gpLineEditRedisplayLine OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the reprint line control character
|
|
sequence.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'redisplay_line'."
|
|
::= { globals 60 }
|
|
|
|
gpLineEditToggleOutput OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..2))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the flush control character used to
|
|
flush the output buffer.
|
|
|
|
This value of this object can be either a single
|
|
displayable character or two characters of the
|
|
form '^x', where '^x' is translated as 'Control-x'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'toggle_output'."
|
|
::= { globals 61 }
|
|
|
|
gpLineEditNewLineTerm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls whether a carriage
|
|
return is echoed as just a carriage return
|
|
(enabled), or whether the carriage return is
|
|
echoed as a carriage return and line feed.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'newline_terminal'."
|
|
::= { globals 62 }
|
|
|
|
|
|
-- Networking Protocol parameters.
|
|
|
|
gpNetLocalAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Internet address for the Annex's side
|
|
of the point-to-point (SLIP or PPP) link.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'local_address'."
|
|
|
|
::= { globals 63 }
|
|
|
|
gpNetRemoteAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The Internet address for the host at the
|
|
remote end of the point-to-point (SLIP or PPP)
|
|
link.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'remote_address'."
|
|
|
|
::= { globals 64 }
|
|
|
|
|
|
gpNetPppDialupAddr OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
local(1),
|
|
authserver(2),
|
|
dhcp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"
|
|
local(1) - The annex will get the
|
|
PPP dialup addresses from the port
|
|
parameters local_address and remote_address.
|
|
|
|
acp(2) - The Annex requests the
|
|
PPP dialup addresses from the host-based
|
|
ACP.
|
|
|
|
dhcp(3) - The Annex requests the
|
|
PPP dialup addresses from the host-based
|
|
DHCP.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous global port
|
|
parameter 'address_origin'."
|
|
::= { globals 65 }
|
|
|
|
|
|
gpNetMetric OBJECT-TYPE
|
|
SYNTAX INTEGER (0..64)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the hop count to
|
|
the remote end of the SLIP or PPP interface.
|
|
Setting this object to 0 defaults to a
|
|
value of 1.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta. synchronous port parameter
|
|
'metric'."
|
|
|
|
::= { globals 66 }
|
|
|
|
gpNetSlipSecure OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If anxEnableSecurity is not set, this
|
|
parameter selects slip session logging. If
|
|
anxEnableSecurity is set, this parameter
|
|
permits slip access only from secure ports.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta and sync port parameter 'slip_ppp_security'."
|
|
::= { globals 67 }
|
|
|
|
gpNetInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of units allowed for serial protocol
|
|
inactivity on the port. The type of unit, minutes
|
|
or seconds, is defined by the object
|
|
anxpNetInactivityUnits. If the type of units is
|
|
'seconds', the actual granularity is only 5
|
|
seconds. When the interval expires,
|
|
the port is automatically reset. A value of 0
|
|
disables the timer.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'net_inactivity'."
|
|
::= { globals 68 }
|
|
|
|
gpNetDoCompression OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex will attempt to negotiate
|
|
TCP/IP header compression on this serial link.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter
|
|
'do_compression'."
|
|
::= { globals 69 }
|
|
|
|
gpNetAllowCompression OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex will allow TCP/IP
|
|
header compression on this serial link only
|
|
if the other end of the serial link initiates
|
|
the compression.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'allow_compression'."
|
|
::= { globals 70 }
|
|
|
|
gpNetInactivityUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minutes(1),
|
|
seconds(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of units that are used for the
|
|
port's net inactivity timer. See also the
|
|
anxpNetInactivity object. The default value
|
|
is 'minutes'.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, synchronous port parameter
|
|
'net_inactivity_units'."
|
|
::= { globals 71 }
|
|
|
|
-- Slip parameters.
|
|
|
|
gpSlipSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subnet mask for this SLIP interface.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'subnet_mask'."
|
|
::= { globals 72 }
|
|
|
|
gpSlipMtuSize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
large(1),
|
|
small(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Force the compressed SLIP interface to use
|
|
a Maximum Transmission Unit (MTU) of either
|
|
1024 bytes (large) or 256 bytes (small). The
|
|
default is large.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'slip_mtu_size'."
|
|
|
|
::= { globals 73 }
|
|
|
|
gpSlipNoIcmp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex will discard any
|
|
ICMP packets directed to this SLIP link.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'slip_no_icmp'."
|
|
::= { globals 74 }
|
|
|
|
gpSlipTos OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the Annex sends interactive
|
|
traffic over this SLIP link before any other
|
|
traffic.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'slip_tos'."
|
|
|
|
::= { globals 75 }
|
|
|
|
-- PPP parameters
|
|
|
|
gpPPPMru OBJECT-TYPE
|
|
SYNTAX INTEGER (64..1500)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the maximum receive
|
|
unit in bytes. The default value is 1500.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, and synchronous port
|
|
parameter 'ppp_mru'."
|
|
::= { globals 76 }
|
|
|
|
gpPPPAcm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (8..10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter specifies which of the first
|
|
32 bytes (0x00, ... 0x1F) can be sent as
|
|
clear text and which need to be escaped. A
|
|
bit on in the mask indicates the character
|
|
must be escaped. The mask should be specified
|
|
as an 8 hex character string (0x1F000000 and
|
|
1F000000 are both acceptable).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'ppp_acm'."
|
|
::= { globals 77 }
|
|
|
|
gpPPPSecurityProto OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
pap(2),
|
|
chap(3),
|
|
chap-pap(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines which security protocol will be used
|
|
to authenticate the remote user. This
|
|
parameter must be set and the Annex
|
|
enable_security (anxEnableSecurity) must be
|
|
enabled before authentication is performed.
|
|
The default is none
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'ppp_security_protocol'."
|
|
::= { globals 78 }
|
|
|
|
gpPPPRemoteUser OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The username used by the Annex to identify
|
|
itself if the remote PPP peer asks for
|
|
authentication.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'ppp_username_remote'."
|
|
::= { globals 79 }
|
|
|
|
gpPPPRemotePasswd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The password used by the Annex to identify
|
|
itself if the remote PPP peer asks for
|
|
authentication. Reading this parameter
|
|
will return either <set> if the password is
|
|
defined or <unset> if the password is not
|
|
defined.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'ppp_password_remote'."
|
|
::= { globals 80 }
|
|
|
|
|
|
gpPPPNcp OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A bitmask to set the PPP NCP Options:
|
|
0x0001 NCP_ALL
|
|
0x0002 NCP_IPCP
|
|
0x0004 NCP_ATCP
|
|
0x0008 NCP_IPXCP
|
|
0x0010 NCP_MP
|
|
0x0020 NCP_CCP
|
|
0x0040 NCP_CBCP
|
|
"
|
|
::= { globals 81 }
|
|
|
|
gpPPPIpxNetwork OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..8))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX network number for an IPX PPP connection
|
|
using this port. When the IPX PPP connection is
|
|
established the network number will be negotiated.
|
|
If one end of the connection is set to zero then
|
|
the value from the other end of the connection will
|
|
be used.
|
|
The value of this object is an 8 digit hexadecimal
|
|
number string representing the IPX network segment
|
|
assigned to this port. The value must be unique
|
|
across the network domain.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'ppp_ipx_network'."
|
|
::= { globals 82 }
|
|
|
|
gpPPPIpxNode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(11..17))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX node number for an IPX PPP connection
|
|
using this port.
|
|
The value of this object is a 12 digit
|
|
hexadecimal number string representing the IPX
|
|
node number assigned to this port.
|
|
Note the string is expected in the form:
|
|
12-3a-4-7-89-23.Each part of the address
|
|
must be a hex value separated by a hyphen.
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta/sync port parameter 'ppp_ipx_node'."
|
|
::= { globals 83 }
|
|
|
|
-- ARAP parameters
|
|
|
|
gpARAPGuest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"If enabled, allows ARAP guest login service.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'at_guest'."
|
|
::= { globals 84 }
|
|
|
|
gpARAPNodeid OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (3..11))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The default AppleTalk node ID hint that is
|
|
used by the Annex on this port. The address
|
|
consists of two parts separated by a dot. The
|
|
address may be in either hex or decimal format.
|
|
The first part is the network address and ranges from
|
|
0 to 65534 (0x0000 to 0xFFFE). The second part
|
|
is the node address and ranges from 0 to 254 (0x00
|
|
to 0xFE).
|
|
|
|
Example:
|
|
|
|
0x00BF.0xFD 191.253 0x00BF.253 191.0xFD
|
|
|
|
are all the same address.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'at_nodeid'."
|
|
::= { globals 85 }
|
|
|
|
gpARAPSecurity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Controls whether ACP service is enabled for
|
|
this port when establishing an AppleTalk
|
|
connection.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'at_security'."
|
|
::= { globals 86 }
|
|
|
|
gpARAPV42BIS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Controls whether V.42bis compression is done
|
|
during an ARAP session.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'arap_v42bis'."
|
|
::= { globals 87 }
|
|
|
|
|
|
-- TN3270 parameters
|
|
|
|
gpTN3270PrinterHost OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The IP address of the machine running a
|
|
Berkeley-style lpd server.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'tn3270_printer_name'."
|
|
::= { globals 88 }
|
|
|
|
gpTN3270PrinterName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A valid printer name contained in the
|
|
/etc/printcap file on the remote host.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'tn3270_printer_name'."
|
|
::= { globals 89 }
|
|
|
|
-- Port LAT parameters
|
|
|
|
gpLATAuthMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..32))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This port parameter is functionally identical to
|
|
anxpLatAuthGroupVal and corresponds to the
|
|
NA/admin Annex parameter 'group_value'.
|
|
|
|
The syntax of this object is an octet string
|
|
32 bytes long, with the first byte
|
|
representing groups 0 through 7 and the last
|
|
byte representing groups 248 through 255.
|
|
|
|
For example, 0x40 0x25 ... means the groups
|
|
1,10,13,15 are valid for this port.
|
|
A returned value with all bits set to zero is the
|
|
same as setting 'group_value' to 'none'.
|
|
The object always returns a string 32 bytes long.
|
|
|
|
Note: You may use either this object or
|
|
anxpLatAuthVal object to read or set the
|
|
'group_value' parameter.anxpLatAuthMap is
|
|
preferred."
|
|
::= { globals 90 }
|
|
|
|
gpLATbEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Controls interpretation of LAT Data-B packets
|
|
received from host.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous/ta port parameter 'latb_enable'."
|
|
|
|
::= { globals 91 }
|
|
|
|
gpLATMultiSession OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This parameter allows multisession operation to
|
|
be managed on a per port basis. If multisessions
|
|
for the server has not been enabled, any attempt
|
|
to use this command will cause the error message
|
|
'ETSMIN-786-Multisession feature Disabled' to be
|
|
displayed.
|
|
|
|
This MIB object corresponds to the NA/admin port
|
|
parameter 'multisessions'.
|
|
|
|
Note: * SNMP will not check for the Annex
|
|
MultiSession parameter.
|
|
* Setting this MIB object is equivalent to
|
|
defining the port parameter 'multisession'
|
|
through NA/admin."
|
|
|
|
::= { globals 92 }
|
|
|
|
|
|
-- parameters from character MIB RFC1316
|
|
|
|
gpcharPortInFlowType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
xonXoff(2),
|
|
hardware(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's type of input flow control. 'none'
|
|
indicates no flow control at this level or below.
|
|
'xonXoff' indicates software flow control by
|
|
recognizing XON and XOFF characters. 'hardware'
|
|
indicates flow control delegated to the lower level,
|
|
for example a parallel port.
|
|
|
|
'ctsRts' and 'dsrDtr' are specific to RS-232-like
|
|
ports. Although not architecturally pure, they are
|
|
included here for simplicity's sake.
|
|
Default is eia or hardware(3)."
|
|
::= { globals 94 }
|
|
|
|
gpcharPortOutFlowType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
xonXoff(2),
|
|
hardware(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's type of output flow control. 'none'
|
|
indicates no flow control at this level or below.
|
|
'xonXoff' indicates software flow control by
|
|
recognizing XON and XOFF characters. 'hardware'
|
|
indicates flow control delegated to the lower level,
|
|
for example a parallel port.
|
|
|
|
'ctsRts' and 'dsrDtr' are specific to RS-232-like
|
|
ports. Although not architecturally pure, they are
|
|
included here for simplicy's sake.
|
|
Default is eia or hardware(3)."
|
|
::= { globals 95 }
|
|
|
|
gpcharPortSessionMaximum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..16)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of concurrent sessions allowed
|
|
on the port. A value of -1 indicates no maximum.
|
|
Setting the maximum to less than the current
|
|
number of sessions has unspecified results.
|
|
Default is 3. This MIB object corresponds to NA/Admin
|
|
parameter 'max_session_count'."
|
|
::= { globals 96 }
|
|
|
|
-- MIB objects from rs232 MIB RFC1317
|
|
|
|
gprs232AsyncPortBits OBJECT-TYPE
|
|
SYNTAX INTEGER (5..8)
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The port's number of bits in a character. This object
|
|
corresponds to the admin parameter data_bits"
|
|
::= { globals 97 }
|
|
|
|
gprs232AsyncPortStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
one(1),
|
|
two(2),
|
|
one-and-half(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The port's number of stop bits. This object corresponds
|
|
to the admin parameter stop_bits"
|
|
::= { globals 98 }
|
|
|
|
gprs232AsyncPortParity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
odd(2),
|
|
even(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The port's sense of a character parity bit."
|
|
::= { globals 99 }
|
|
|
|
gpV120Mru OBJECT-TYPE
|
|
SYNTAX INTEGER (30..260)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter defines the maximum receive
|
|
unit in bytes. The default value is 256.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, and synchronous port
|
|
parameter 'v120_mru'."
|
|
::= { globals 101 }
|
|
|
|
gpMpMrru OBJECT-TYPE
|
|
SYNTAX INTEGER (64..1600)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter sets the upper limit of
|
|
the MRRU LCP negotiation. All LCP
|
|
negotiations will start with this value;
|
|
negotiation downward only is allowed.
|
|
The default value is 1500.
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, and synchronous port
|
|
parameter `mp_mrru'."
|
|
::= { globals 102 }
|
|
|
|
gpMpEndPointClass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nullclass(1),
|
|
local(2),
|
|
unitipaddr(3),
|
|
unitmacaddr(4),
|
|
psnDirNbr(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter sets the preference for the
|
|
Endpoint Discriminator. PPP Magic Number
|
|
Block(5) isexcluded; it doesn't guarantee
|
|
unique link identities and could lead to
|
|
illegal bundle memebership.
|
|
The default is unitmacaddr(4).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, and synchronous port
|
|
parameter `mp_endpoint_option'."
|
|
::= { globals 103}
|
|
|
|
gpMpEndPointValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter sets the value of the
|
|
Endpoint Discriminator for options that
|
|
require user-configured information.
|
|
This parameter is only valid when
|
|
gpMPEndPointClass is set to Public Switched
|
|
Network Directory Number E.164 (6).
|
|
|
|
This MIB object corresponds to the NA/admin
|
|
asynchronous, ta, and synchronous port
|
|
parameter `mp_endpoint_address'."
|
|
::= { globals 104}
|
|
|
|
gpProxyArpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies whether the Annex will proxy
|
|
ARP all remote IP connections. A value
|
|
of enabled(1) will allow the Annex to proxy
|
|
all remote IP connections. A value of
|
|
disabled(2) allows the Annex to proxy only
|
|
remote IP connections having the same
|
|
subnet address as the Annex.
|
|
|
|
This MIB object corresponds to the
|
|
NA/admin global port parameter
|
|
'proxy_arp_enabled'."
|
|
::= { globals 105}
|
|
|
|
gpPPPTraceLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
control(1),
|
|
data(2),
|
|
control-and-data(3),
|
|
unused(4),
|
|
control-in-hex(5),
|
|
data-in-hex(6),
|
|
control-and-data-in-hex(7),
|
|
none(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controls whether PPP trace messages are sent to the
|
|
syslog facility or not. The default value is none(0).
|
|
This MIB object corresponds to the na/admin port parameter
|
|
ppp_trace_level."
|
|
::= { globals 106 }
|
|
|
|
-- anxtunnelport for UDAS
|
|
|
|
anxTunnelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AnxTunnelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of tunnel entries."
|
|
::= { anxtunnelport 1 }
|
|
|
|
anxTunnelEntry OBJECT-TYPE
|
|
SYNTAX AnxTunnelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A UDAS Tunnel entry."
|
|
INDEX { anxTunnelLineIndex, anxTunnelUnitIndex }
|
|
::= { anxTunnelTable 1 }
|
|
|
|
AnxTunnelEntry ::= SEQUENCE {
|
|
anxTunnelLineIndex INTEGER,
|
|
anxTunnelUnitIndex INTEGER,
|
|
anxTunnelWanProtocol INTEGER,
|
|
anxTunnelWanAddress OCTET STRING,
|
|
anxTunnelState INTEGER,
|
|
anxTunnelMnIPAddress IpAddress,
|
|
anxTunnelMnIPXAddress DisplayString,
|
|
anxTunnelHaAddress IpAddress
|
|
}
|
|
|
|
anxTunnelLineIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..'7fffffff'h) -- Change `7fffffff'h to
|
|
ACCESS read-only -- 2147483647 for mib2schema
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
DS1 interface to which this entry is applicable.
|
|
The interface identified by a particular value
|
|
of this index is the same interface as identified
|
|
by the same value of ifIndex from the Interfaces
|
|
table of MIB-II (RFC 1213). This is unused for
|
|
the ra2000, ra4000 platforms but needs to be
|
|
filled in with a 1.
|
|
|
|
Look at anxt1WanModuleTable for an alternative way
|
|
of getting the interface number for a physical WAN
|
|
module"
|
|
::= { anxTunnelEntry 1 }
|
|
|
|
anxTunnelUnitIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..3000)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"On a PRI interface, this is a call's B channel number ranging
|
|
from 1 to anxt1TotChan. On a port interface, this
|
|
is the port number ranging from 1 to ports.totalports."
|
|
::= { anxTunnelEntry 2 }
|
|
|
|
|
|
anxTunnelWanProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
serial-line(1),
|
|
ppp(2),
|
|
framerelay(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field describes the protocol used
|
|
on the WAN interface from the Gateway
|
|
(or Home Agent) to the customer premise
|
|
equipment (CPE)."
|
|
::= { anxTunnelEntry 3 }
|
|
|
|
anxTunnelWanAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field describes the WAN Address from the
|
|
Gateway (or Home Agent) to the customer
|
|
premise equipment (CPE)."
|
|
::= { anxTunnelEntry 4 }
|
|
|
|
anxTunnelState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reserved(1),
|
|
pending(2),
|
|
registered(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This fields describes the Tunnel's
|
|
current state.
|
|
reserved - visitor added,
|
|
authentication in progress
|
|
pending - authentication complete,
|
|
registration requisition has been sent
|
|
to gateway, tunnel not registered yet
|
|
registered - tunnel is up"
|
|
|
|
::= { anxTunnelEntry 5 }
|
|
|
|
anxTunnelMnIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP Address of the Remote Node."
|
|
::= { anxTunnelEntry 6 }
|
|
|
|
anxTunnelMnIPXAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPX Address of the Remote Node."
|
|
::= { anxTunnelEntry 7 }
|
|
|
|
anxTunnelHaAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP Address assigned to the Home Agent."
|
|
::= { anxTunnelEntry 8 }
|
|
|
|
-- ss7 MIB objects
|
|
|
|
ss7Pref1SigGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the primary SS7 gateway.
|
|
The default value is 0.0.0.0.
|
|
This MIB object corresponds to the NA/admin
|
|
parameter 'pref1_sig_gateway'."
|
|
::= { ss7 1 }
|
|
|
|
ss7Pref2SigGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the primary secondary SS7 gateway.
|
|
This may be zero if a redundant SS7 gateway is not
|
|
available.
|
|
The default value is 0.0.0.0.
|
|
This MIB object corresponds to the NA/admin
|
|
parameter 'pref2_sig_gateway'."
|
|
::= { ss7 2 }
|
|
|
|
ss7Pref1SigPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The TCP port number used on the primary SS7 gateway.
|
|
The default is 1000.
|
|
This MIB object corresponds to the NA/admin parameter
|
|
'pref1_sig_port'."
|
|
::= { ss7 3 }
|
|
|
|
ss7Pref2SigPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The TCP port number used on the secondary SS7 gateway.
|
|
The default is 1000. This entry is zero if no redundant
|
|
SS7 gateway is available.
|
|
This MIB object corresponds to the NA/admin parameter
|
|
'pref2_sig_port'."
|
|
::= { ss7 4 }
|
|
|
|
ss7SigKeepalive OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum time to wait for a packet to be received from
|
|
SS7 server. This value is in seconds. The default value is
|
|
15 seconds.
|
|
This MIB object corresponds to the NA/admin parameter
|
|
'sig_keepalive'."
|
|
::= { ss7 5 }
|
|
|
|
|
|
ss7CurrentGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The address of the current SS7 server. This can
|
|
change dynamically depending on the state of the
|
|
server."
|
|
::= { ss7 6 }
|
|
|
|
ss7ConnectionTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" Time at which this connection was established
|
|
to the current SS7 Gateway."
|
|
::= { ss7 7 }
|
|
|
|
ss7Registration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notregistered(1),
|
|
incoming(2),
|
|
both(3),
|
|
rasregreject(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Describes whether the RAS can accept and/or receive
|
|
calls. This is set by the ss7 gateway."
|
|
::= { ss7 8 }
|
|
|
|
ss7ChanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ss7ChanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" Table of ss7 Channel information."
|
|
::= { ss7 9 }
|
|
|
|
ss7ChanEntry OBJECT-TYPE
|
|
SYNTAX Ss7ChanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ss7 channel information."
|
|
INDEX { ss7WanIndex, ss7ChanNumber }
|
|
::= { ss7ChanTable 1 }
|
|
|
|
Ss7ChanEntry ::= SEQUENCE {
|
|
ss7WanIndex INTEGER,
|
|
ss7ChanNumber INTEGER,
|
|
ss7ChanStatus INTEGER,
|
|
ss7ChanState INTEGER
|
|
}
|
|
|
|
ss7WanIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
Wan Module."
|
|
::= { ss7ChanEntry 1 }
|
|
ss7ChanNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
Channel Numnber."
|
|
::= { ss7ChanEntry 2 }
|
|
|
|
ss7ChanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle(1),
|
|
busy(2),
|
|
blocked(3),
|
|
blocking(4),
|
|
unblocking(5),
|
|
loopback(6),
|
|
restarting(7),
|
|
continuityTest(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the ds0 channel.
|
|
idle(1) - the DS0 is available for calls
|
|
busy(2) - call is in progress
|
|
blocked(3) - the RAS of the gateway requested block
|
|
unblocking(4) -
|
|
loopback(5) - loopback requested by the gateway
|
|
restarting(6) - DS0 restart requested by the gateway
|
|
continuityTest(7) - the RAS or the gateway requested continuity test
|
|
"
|
|
::= { ss7ChanEntry 3 }
|
|
|
|
ss7ChanState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle(1),
|
|
connected(2),
|
|
waitReleaseComplete(3),
|
|
waitATConnect(4),
|
|
waitRelease(5),
|
|
waitConnect(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the ds0 channel.
|
|
idle(1) - no call in progress
|
|
connected(2) - call fully established.
|
|
waitReleaseComplete(3) - waiting for Release Complete
|
|
from gateway.
|
|
waitATConnect(4) - waiting for connect from WAN
|
|
manager.
|
|
waitRelease(5) - waiting for Release from gateway.
|
|
waitConnect(6) - waiting for connect from gateway."
|
|
::= { ss7ChanEntry 4 }
|
|
|
|
-- nfas MIB objects
|
|
|
|
nfasPref1SigGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the primary nfas gateway.
|
|
The default value is 0.0.0.0.
|
|
This MIB object corresponds to the NA/admin
|
|
parameter 'pref1_sig_gateway'."
|
|
::= { nfas 1 }
|
|
|
|
nfasPref2SigGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the backup nfas gateway.
|
|
The default value is 0.0.0.0.
|
|
This MIB object corresponds to the NA/admin
|
|
parameter 'pref2_sig_gateway'."
|
|
::= { nfas 2 }
|
|
|
|
nfasPref1SigPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The TCP port number used on the primary nfas gateway.
|
|
This MIB object corresponds to the NA/admin parameter
|
|
'pref1_sig_port'."
|
|
::= { nfas 3 }
|
|
|
|
nfasPref2SigPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The TCP port number used on the nfas backup gateway.
|
|
This MIB object corresponds to the NA/admin parameter
|
|
'pref2_sig_port'."
|
|
::= { nfas 4 }
|
|
|
|
nfasGroupName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a trap to indicate the nfas group name."
|
|
::= { nfas 5 }
|
|
|
|
nfasDchannelstate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This will indicate whether this interface is
|
|
Active or Inactive : 1-Active, 2-Inactive."
|
|
::= { nfas 6 }
|
|
|
|
|
|
nfasConnectionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NfasConnectionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of nfas connection information."
|
|
::= { nfas 7 }
|
|
|
|
nfasConnectionEntry OBJECT-TYPE
|
|
SYNTAX NfasConnectionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nfas connection information."
|
|
INDEX { nfasInterfaceNo }
|
|
::= { nfasConnectionTable 1 }
|
|
|
|
NfasConnectionEntry ::= SEQUENCE {
|
|
nfasInterfaceStatus DisplayString,
|
|
nfasIpAddress IpAddress,
|
|
nfasDchannelStatus DisplayString,
|
|
nfasConnectStatus DisplayString,
|
|
nfasInterfaceNo INTEGER
|
|
}
|
|
|
|
nfasInterfaceStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of interface - Primary,Backup or Bearer."
|
|
::= { nfasConnectionEntry 1 }
|
|
|
|
nfasIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP Address of the Interface."
|
|
::= { nfasConnectionEntry 2 }
|
|
|
|
nfasDchannelStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The D Channel Status - Active or Inactive."
|
|
::= { nfasConnectionEntry 3 }
|
|
|
|
nfasConnectStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nfas connect status - Connected or Disconnected."
|
|
::= { nfasConnectionEntry 4 }
|
|
|
|
nfasInterfaceNo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nfas interface number which could be beween 0-19.
|
|
The Interface No for the primary is always 0."
|
|
::= { nfasConnectionEntry 5 }
|
|
|
|
nfasConnectionStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a trap to indicate the nfas connection status
|
|
between Primary,Backup and Bearer ."
|
|
::= { nfas 8 }
|
|
|
|
nfasBackupStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a trap to indicate the nfas switch-over status."
|
|
::= { nfas 9 }
|
|
|
|