-- The Wyse Enterprise number is 714
-- 09/09/99 ble Changed to compile with other MIB compilers.
-- 07/28/99 ble Added new trap error code: LS_FAIL_BADKEY
-- 07/09/99 mla Add detail descriptions on wbt3UsersTable
-- 07/07/99 mla Add wbt3RDPConnModifiable, wbt3ICAConnModifiable AND wbt3TermConnModifiable
-- 07/01/99 ble Update wbt3UsersTable, Mib revision to 1.8
-- objects in wbt3DispCharacteristic group can be set.
-- added wbt3DispUseDDC.
-- 06/29/99 mla Update wbt3ConnectionsTable, Mib revision to 1.7
-- 06/16/99 ble Added new trap error code: LS_INVALID_BOOTSTRAP
-- 06/03/99 ble Updated Mib revision 1.6
-- 05/30/99 ble Added new trap error code: LS_FAIL_PARAMINIFILENOTFOUND
-- 05/17/99 ble Added wbt3TermConnVTEmuModel, wbt3TermConnIBM3270EmuModel,
-- wbt3TermConnIBM5250EmuModel and wbt3TermConnScript.
-- 05/11/99 ble Changed wbt3UserName in wbt3Security group to wbt3AutoLoginUserName.
-- Added new wbt3ResetToFactoryDefault object under wbt3Administration\
-- wbt3Action to reset the terminal to factory-default settings.
-- Added new trap error code: LS_FAIL_RESET_DEFAULTFACTORY
-- Added new wbt3TermConnections under wbt3Connections.
-- 04/29/99 ble Added wbt3CharacterRepeatDelay, wbt3CharacterRepeatRate,
-- wbt3NetworkSpeed.
-- 04/21/99 ble Moved wbt3Users group under wbt3Administration group to wbt3 group.
-- 04/20/99 ble Created new group wbt3Connections and moved the wbt3ConnectionsTable
-- from wbt3Network. Changed all TcpIp to Network for future uses with
-- different protocol than TCP and added wbt3NetworkProtocol.
-- 04/05/99 ble Added wbt3Security group under wbt3Administration
-- 03/28/99 ble Changed wbt3BuildInfo to be displayed as table.
-- enhancements. Added new groups: wbt3Users, wbt3connections.
-- 02/25/99 ble Added DNS and WINS objects under wbt3Network group.
-- Added new keyboards local under wbt3kbLanguage.
-- 02/10/99 ble Added wbt3EnergySavers object under wbt3Display group.
-- 01/20/99 ble enhancements. Added new groups: wbt3Apps, wbt3DHCPoptionIDs,
-- wbt3TouchScreen and wbt3InfoLocation.
-- 01/07/99 ble enhancements. Added new groups: wbt3Network, wbt3Trapservers,
-- wbt3FTPsetting...
-- 10/20/98 sjl Change product id to 3 for 3000 series
-- Last Modified 09/09/99
-- The ASN.1 prefix to, and including the Wyse Enterprise is:
-- 1.3.6.1.4.1.714
-- See wbtmib.txt for the tree structure of the wyse MIB described in this
-- document
-- ****************************************************************************
WYSE-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215;
wyse OBJECT IDENTIFIER ::= { enterprises 714 }
-- groups in wyse
Product OBJECT IDENTIFIER ::= { wyse 1 }
-- ****************************************************************************
-- the Product group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
--
-- Implementation of the Product group is mandatory for all SNMP agents supporting
-- the wyse MIB
-- ****************************************************************************
-- groups in Product
Old OBJECT IDENTIFIER ::= {Product 1}
ThinClient OBJECT IDENTIFIER ::= {Product 2}
-- ****************************************************************************
-- the Old group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- Old Group (1.3.6.4.1.714.1.1)
-- This is old MIB mainly for X5 & Netbox
-- No official document can be found about this group. The only information we
-- could get in this tree is Netbox's product number. It seems that nothing
-- has been defined under Netbox's subtree
-- ****************************************************************************
-- groups in Old
Wysenet OBJECT IDENTIFIER ::= {Old 1}
-- ****************************************************************************
-- the ThinClient group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
--
-- Implementation of the ThinClient group is mandatory for all ThinClient products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
-- groups in ThinClient
wbt3 OBJECT IDENTIFIER ::= {ThinClient 3}
-- ****************************************************************************
-- the wbt3 group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
--
-- Implementation of the wbt3 group is mandatory for all wbt3 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
-- group in wbt3
wbt3Memory OBJECT IDENTIFIER ::= {wbt3 1}
wbt3PCCard OBJECT IDENTIFIER ::= {wbt3 2}
wbt3IODevice OBJECT IDENTIFIER ::= {wbt3 3}
wbt3Display OBJECT IDENTIFIER ::= {wbt3 4}
wbt3DhcpInfo OBJECT IDENTIFIER ::= {wbt3 5}
wbt3BuildInfo OBJECT IDENTIFIER ::= {wbt3 6}
wbt3CustomFields OBJECT IDENTIFIER ::= {wbt3 7}
wbt3Administration OBJECT IDENTIFIER ::= {wbt3 8}
wbt3TrapsInfo OBJECT IDENTIFIER ::= {wbt3 9}
wbt3MibRev OBJECT IDENTIFIER ::= {wbt3 10}
wbt3Network OBJECT IDENTIFIER ::= {wbt3 11}
wbt3Apps OBJECT IDENTIFIER ::= {wbt3 12}
wbt3Connections OBJECT IDENTIFIER ::= {wbt3 13}
wbt3Users OBJECT IDENTIFIER ::= {wbt3 14}
-- ****************************************************************************
-- the wbt3Memory group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Memory Group (1.3.6.4.1.714.1.2.3.1)
--
-- Implementation of the wbt3Memory group is mandatory for all ThinClient2 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
-- group in wbt3Memory
wbt3Ram OBJECT IDENTIFIER ::= {wbt3Memory 1}
wbt3Rom OBJECT IDENTIFIER ::= {wbt3Memory 2}
-- ****************************************************************************
-- the wbt3Ram group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Memory Group (1.3.6.4.1.714.1.2.3.1)
-- wbt3Ram Group (1.3.6.4.1.714.1.2.3.1.1)
--
-- Implementation of the wbt3Ram group is mandatory for all ThinClient2 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3RamNum OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Ram presents in this system"
::={wbt3Ram 1}
wbt3RamTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3RamEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Ram entries, number of entries is given by the
value of wbt3RamNum"
::={wbt3Ram 2}
wbt3RamEntry OBJECT-TYPE
SYNTAX wbt3RamEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A Ram entity present in this system"
INDEX {wbt3RamIndex}
::={wbt3RamTable 1}
wbt3RamEntry ::=
SEQUENCE {
wbt3RamIndex
INTEGER,
wbt3RamType
INTEGER,
wbt3RamSize
INTEGER
}
wbt3RamIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each Ram entity present in this system.
Its value ranges between 1 and the value of wbt3RamNum"
::={wbt3RamEntry 1}
wbt3RamType OBJECT-TYPE
SYNTAX INTEGER {
base(1),
video(2),
extend(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of Ram
Currently defined numbers are:
base(1)
video(2)
extend(3)"
::={wbt3RamEntry 2}
wbt3RamSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total size of this ram entity in bytes"
::={wbt3RamEntry 3}
-- ****************************************************************************
-- the wbt3Rom group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Memory Group (1.3.6.4.1.714.1.2.3.1)
-- wbt3Rom Group (1.3.6.4.1.714.1.2.3.1.2)
--
-- Implementation of the wbt3Rom group is mandatory for all ThinClient2 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3RomNum OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Rom entity presents in this system"
::={wbt3Rom 1}
wbt3RomTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3RomEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Rom entries, number of entries is given by the
value of wbt3RomNum"
::={wbt3Rom 2}
wbt3RomEntry OBJECT-TYPE
SYNTAX wbt3RomEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A Rom entity present in this system"
INDEX {wbt3RomIndex}
::={wbt3RomTable 1}
wbt3RomEntry ::=
SEQUENCE {
wbt3RomIndex
INTEGER,
wbt3RomType
INTEGER,
wbt3RomSize
INTEGER
}
wbt3RomIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each Rom entity present in this system.
Its value ranges between 1 and the value of wbt3RomNum"
::={wbt3RomEntry 1}
wbt3RomType OBJECT-TYPE
SYNTAX INTEGER {
boot(1),
os(2),
option(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of Rom
Currently defined numbers are:
boot(1)
os(2)
option(3)"
::={wbt3RomEntry 2}
wbt3RomSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total size of this Rom entity in bytes"
::={wbt3RomEntry 3}
-- ****************************************************************************
-- the wbt3PCCard group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3PCCard Group (1.3.6.4.1.714.1.2.3.2)
--
-- Implementation of the wbt3PCCard group is mandatory for all ThinClient2 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3PCCardNum OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PCCard slots presents in this system"
::={wbt3PCCard 1}
wbt3PCCardTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3PCCardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PCCard entries, number of entries is given by the
value of wbt3PCCardNum"
::={wbt3PCCard 2}
wbt3PCCardEntry OBJECT-TYPE
SYNTAX wbt3PCCardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A PCCard slot present in this system"
INDEX {wbt3PCCardIndex}
::={wbt3PCCardTable 1}
wbt3PCCardEntry ::=
SEQUENCE {
wbt3PCCardIndex
INTEGER,
wbt3PCCardType
INTEGER,
wbt3PCCardVendor
DisplayString
}
wbt3PCCardIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each PCCard slot present in this system.
Its value ranges between 1 and the value of wbt3PCCardNum"
::={wbt3PCCardEntry 1}
wbt3PCCardType OBJECT-TYPE
SYNTAX INTEGER {
empty(256), -- the PCCard slot is empty
multifunction(0), -- a multi function PCCard card is currently in the PCCard slot
memory(1),
serial_port-modem(2),
parallel_port(3),
fixed_disk(4),
video_adaptor(5),
lan_adapter(6),
AIMS(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of PCCard card currently plugged in this PCCard slot.
Currently defined numbers are:
empty(65535), -- the PCCard slot is empty
multifunction(0), -- a multi function PCCard card is currently in the PCCard slot
memory(1),
modem(2),
parallel_port(3),
fixed_disk(4),
video_adaptor(5),
lan_adapter(6),
AIMS(7)"
::={wbt3PCCardEntry 2}
wbt3PCCardVendor OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the vendor of the PCCard card currently
plugged in this slot. e.g. 'Eicon DIVA PC Card'"
::={wbt3PCCardEntry 3}
-- ****************************************************************************
-- the wbt3IODevice Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3IODevice Group (1.3.6.4.1.714.1.2.3.3)
--
-- Implementation of the wbt3IODevice Group is mandatory for all ThinClient2 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3IODevAttached OBJECT-TYPE
SYNTAX INTEGER(1..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A 32bit value which indicates the input devices currently
attached to the unit.
bit 0 - set if keyboard attached
bit 1 - set if mouse driver loaded
bit 2 - set if micro touch screen attached
bit 3 - set if elo touch screen attached
bit 4 - set if lightpen attached
bit 5 - set if floppy drive attached"
::={wbt3IODevice 1}
wbt3kbLanguage OBJECT-TYPE
SYNTAX INTEGER {
English-US(0),
English-UK(1),
French(2),
German(3),
Spanish(4),
Italian(5),
Swedish(6),
Danish(7),
Norwegian(8),
Dutch(9),
Belgian-French(10),
Finnish(11),
Swiss-French(12),
Swiss-German(13),
Japanese(14),
Canadian-French(15),
Belgian-Dutch(16),
Portuguese(17),
Brazilian-ABNT(18),
Italian-142(19),
Latin-American(20),
US-International(21),
Canadian-FR-Multi(22),
Canadian-Eng-Multi(23),
Spanish-Variation(24)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The language setting for the keyboard attached to this terminal"
::={wbt3IODevice 2}
wbt3CharacterRepeatDelay OBJECT-TYPE
SYNTAX INTEGER {
R250(250),
R500(500),
R750(750),
R1000(1000)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the delay time between each character."
::={wbt3IODevice 3}
wbt3CharacterRepeatRate OBJECT-TYPE
SYNTAX INTEGER(0..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates repeat rate between each character in the range of 0 to 31 at 1 interval."
::={wbt3IODevice 4}
-- ****************************************************************************
-- the wbt3Display Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Display Group (1.3.6.4.1.714.1.2.3.4)
--
-- Implementation of the wbt3Display Group is mandatory for all ThinClient2 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
-- group in wbt3Display
wbt3DispCharacteristic OBJECT IDENTIFIER ::= {wbt3Display 1}
wbt3DispCapability OBJECT IDENTIFIER ::= {wbt3Display 2}
wbt3EnergySaver OBJECT-TYPE
SYNTAX INTEGER {
None(0),
screenSaver(1),
monitorOff(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates which energy saver is in use."
::={wbt3Display 3}
wbt3ScreenTimeOut OBJECT-TYPE
SYNTAX INTEGER(1..1440)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the time (in minutes) of non-activity to trigger
the screen saver."
::={wbt3Display 4}
wbt3TouchScreen OBJECT-TYPE
SYNTAX INTEGER {
None(0),
COM1(1),
COM2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the terminal has a touch screen, indicates to which port it is attached"
::={wbt3Display 5}
-- ****************************************************************************
-- the wbt3DispCharacteristic Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Display Group (1.3.6.4.1.714.1.2.3.4)
-- wbt3DispCharacteristic Group (1.3.6.4.1.714.1.2.3.4.1)
--
-- Implementation of the wbt3DispCharacteristic Group is mandatory for all ThinClient2 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3DispFreq OBJECT-TYPE
SYNTAX INTEGER(1..256)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A 8bit value which indicates the current display frequency in Hz.
Available display frequency values for Leo: 60/75/85 Hz,
for Mars/Midway: 60/75 Hz.
wbt3DispFreq can not be set if use DDC is on."
::={wbt3DispCharacteristic 1}
wbt3DispHorizPix OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A 16bit value which indicates the current number of horizontal pixels.
Available display horizontal pixel values
for Leo: 640/800/1024/1280 (1280 only with 60 Hz) pixels,
for Mars/Midway: 640/800/1024.
wbt3DispHorizPix can not be set if use DDC is on."
::={wbt3DispCharacteristic 2}
wbt3DispVertPix OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A 16bit value which indicates the current number of vertical pixels.
Available display vertical pixel values
for Leo: 480/600/768/1024 (1024 only with 60 Hz) pixels,
for Mars/Midway: 480/600/768.
wbt3DispVertPix can not be set if use DDC is on."
::={wbt3DispCharacteristic 3}
wbt3DispColor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current display color depth"
::={wbt3DispCharacteristic 4}
wbt3DispUseDDC OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Automatic select the best available resolution and refresh rate.
If selected Yes, the wbt3DispHorizPix, wbt3VertPix and wbt3DispFreq
options can not be set.
Use DDC is not available for Mars platform."
::={wbt3DispCharacteristic 5}
-- ****************************************************************************
-- the wbt3DispCapability Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Display Group (1.3.6.4.1.714.1.2.3.4)
-- wbt3DispCapability Group (1.3.6.4.1.714.1.2.3.4.2)
--
-- Implementation of the wbt3DispCapability Group is mandatory for all ThinClient2 products
-- with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3DispFreqMax OBJECT-TYPE
SYNTAX INTEGER(1..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A 8bit value which indicates the display frequency in Hz for maximum resolution"
::={wbt3DispCapability 1}
wbt3DispHorizPixMax OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A 16bit value which indicates the maximum number of horizontal pixels"
::={wbt3DispCapability 2}
wbt3DispVertPixMax OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A 16bit value which indicates the maximum number of vertical pixels"
::={wbt3DispCapability 3}
wbt3DispColorMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum display color depth"
::={wbt3DispCapability 4}
-- ****************************************************************************
-- the wbt3DhcpInfo Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3DhcpInfo Group (1.3.6.4.1.714.1.2.3.5)
--
-- Implementation of the wbt3DhcpInfo Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3DhcpInfoNum OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of entries in DHCP information table, this number equals to the number
of currently initialized network interfaces (exclude loopback) in the terminal"
::={wbt3DhcpInfo 1}
wbt3DhcpInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3DhcpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of DHCP information table entry, Each entry lists the information
obtained from DHCP server through a specific network interface in the terminal.
The number of entries is given by the value of wbt3DhcpInfoNum"
::={wbt3DhcpInfo 2}
-- group in wbt3DhcpInfo
wbt3DHCPoptionIDs OBJECT IDENTIFIER ::= {wbt3DhcpInfo 3}
wbt3DhcpInfoEntry OBJECT-TYPE
SYNTAX wbt3DhcpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An interface with a DHCP information table entry on this system"
INDEX {wbt3DhcpInfoIndex}
::={wbt3DhcpInfoTable 1}
wbt3DhcpInfoEntry ::=
SEQUENCE {
wbt3DhcpInfoIndex
INTEGER,
wbt3InterfaceNum
INTEGER,
wbt3ServerIP
DisplayString,
wbt3Username1
DisplayString,
wbt3Domain
DisplayString,
wbt3Password
INTEGER,
wbt3CommandLine
DisplayString,
wbt3WorkingDir
DisplayString,
wbt3FileServer
DisplayString,
wbt3FileRootPath
DisplayString,
wbt3TrapServerList
DisplayString,
wbt3SetCommunity
INTEGER
}
wbt3DhcpInfoIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for this DHCP information table, Its value ranges
between 1 and the value of wbt3DhcpInfoNum."
::={wbt3DhcpInfoEntry 1}
wbt3InterfaceNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interface number through which the dhcp info is obtained"
::={wbt3DhcpInfoEntry 2}
wbt3ServerIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WinFrame/WTS Server IP address, (Option 155)"
::={wbt3DhcpInfoEntry 3}
wbt3Username1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Account to logon to WinFrame/WTS Server, (Option 156)"
::={wbt3DhcpInfoEntry 4}
wbt3Domain OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Domain to authenticate account defined by wbt3Username, (Option 157)"
::={wbt3DhcpInfoEntry 5}
wbt3Password OBJECT-TYPE
SYNTAX INTEGER {
NoPassword(0),
Password(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0=No Password;1=Has Password, (Option 158)"
::={wbt3DhcpInfoEntry 6}
wbt3CommandLine OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Application to use when connecting to a WinFrame/WTS Server, (Option 159)"
::={wbt3DhcpInfoEntry 7}
wbt3WorkingDir OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Working Directory for application defined by wbt3CommandLine, (Option 160)"
::={wbt3DhcpInfoEntry 8}
wbt3FileServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"File server where ROM images are located, (Option 161)"
::={wbt3DhcpInfoEntry 9}
wbt3FileRootPath OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Absolute path name for ROM image parent directory, (Option 162)"
::={wbt3DhcpInfoEntry 10}
wbt3TrapServerList OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A list of host IPs which should receive SNMP trap from the terminal (Option 163)"
::={wbt3DhcpInfoEntry 11}
wbt3SetCommunity OBJECT-TYPE
SYNTAX INTEGER {
Ignored(0),
Provided(1),
NotProvided(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMP Set Community (Option 164):
0 - dhcp supplied set community is ignored,
local configuration takes precedence;
1 - provided by DHCP server and being used;
2 - not provided by DHCP server, default set community is used"
::={wbt3DhcpInfoEntry 12}
wbt3RDPstartApp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RDP option: Startup Application (Default Option 165)"
::={wbt3DhcpInfoEntry 13}
wbt3EmulationMode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Terminal Emulation option: Emulation Mode (Default Option 166)"
::={wbt3DhcpInfoEntry 14}
wbt3TerminalID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Terminal Emulation option: Terminal ID (Default Option 167)"
::={wbt3DhcpInfoEntry 15}
wbt3VirtualPortServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual Port option: Virtual Port Server (Default Option 168)"
::={wbt3DhcpInfoEntry 16}
-- ****************************************************************************
-- the wbt3DHCPoptionIDs Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3DhcpInfo Group (1.3.6.4.1.714.1.2.3.5)
-- wbt3DHCPoptionIDs Group (1.3.6.4.1.714.1.2.3.5.3)
--
-- Implementation of the wbt3DhcpInfo Group is mandatory for all ThinClient
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
RemoteServer OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Common option: Remote Server (Default Option 155)"
::={wbt3DHCPoptionIDs 1}
LogonUserName OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Common option: Logon User Name (Default Option 156)"
::={wbt3DHCPoptionIDs 2}
Domain OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Common option: Domain (Default Option 157)"
::={wbt3DHCPoptionIDs 3}
Password OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Common option: Login Password (Default Option 158)"
::={wbt3DHCPoptionIDs 4}
CommandLine OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Common option: Command Line (Default Option 159)"
::={wbt3DHCPoptionIDs 5}
WorkingDirectory OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Common option: Working Directory (Default Option 160)"
::={wbt3DHCPoptionIDs 6}
FTPFileServer OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP option: File Server (Default Option 161)"
::={wbt3DHCPoptionIDs 8}
FTPRootPath OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP option: File Root Path (Default Option 162)"
::={wbt3DHCPoptionIDs 9}
TrapServerList OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNMP option: Trap Server IP List (Default Option 163)"
::={wbt3DHCPoptionIDs 10}
SetCommunity OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNMP option: Set Community (Default Option 164)"
::={wbt3DHCPoptionIDs 11}
RDPStartupApp OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RDP option: Startup Application (Default Option 165)"
::={wbt3DHCPoptionIDs 7}
EmulationMode OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Terminal Emulation option: Emulation Mode (Default Option 166)"
::={wbt3DHCPoptionIDs 12}
TerminalID OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Terminal Emulation option: Terminal ID (Default Option 167)"
::={wbt3DHCPoptionIDs 13}
VirtualPortServer OBJECT-TYPE
SYNTAX INTEGER(128..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Port option: Virtual Port Server (Default Option 168)"
::={wbt3DHCPoptionIDs 14}
-- ****************************************************************************
-- the wbt3BuildInfo Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3BuildInfo Group (1.3.6.4.1.714.1.2.3.6)
--
-- Implementation of the wbt3BuildInfo Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
-- group in wbt3BuildInfo
wbt3CurrentInfo OBJECT IDENTIFIER ::= {wbt3BuildInfo 1}
wbt3DhcpUpdateInfo OBJECT IDENTIFIER ::= {wbt3BuildInfo 2}
-- ****************************************************************************
-- the wbt3CurrentInfo Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3BuildInfo Group (1.3.6.4.1.714.1.2.3.6)
-- wbt3CurrentInfo Group (1.3.6.4.1.714.1.2.3.6.1)
--
-- Implementation of the wbt3CurrentInfo Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3CurInfoNum OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rom images reside in the terminal currently, include main & application"
::={wbt3CurrentInfo 1}
wbt3CurInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3CurInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of build info for each rom image, number of entries
is given by the value of wbt3CurInfoNum"
::={wbt3CurrentInfo 2}
wbt3CurInfoEntry OBJECT-TYPE
SYNTAX wbt3CurInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A rom image present in this terminal"
INDEX {wbt3CurInfoIndex}
::={wbt3CurInfoTable 1}
wbt3CurInfoEntry ::=
SEQUENCE {
wbt3CurInfoIndex
INTEGER,
wbt3CurBuildNum
DisplayString,
wbt3CurOEMBuildNum
DisplayString,
wbt3CurModBuildDate
DisplayString,
wbt3CurOEM
DisplayString,
wbt3CurHWPlatform
DisplayString,
wbt3CurOS
DisplayString
}
wbt3CurInfoIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for this rom image. Its value ranges between
1 and the value of wbt3CurInfoNum.."
::={wbt3CurInfoEntry 1}
wbt3CurBuildNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Build number of a rom image currently on the terminal"
::={wbt3CurInfoEntry 2}
wbt3CurOEMBuildNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Build number of flash ROM image currently on the terminal for OEM"
::={wbt3CurInfoEntry 3}
wbt3CurModBuildDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date that ROM image currently on the terminal was created"
::={wbt3CurInfoEntry 4}
wbt3CurOEM OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of OEM who's ROM image is defined by wbt3OEMBuildNum"
::={wbt3CurInfoEntry 5}
wbt3CurHWPlatform OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OS installed on the terminal"
::={wbt3CurInfoEntry 6}
wbt3CurOS OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OS installed on the terminal"
::={wbt3CurInfoEntry 7}
-- ****************************************************************************
-- the wbt3DhcpUpdateInfo Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3BuildInfo Group (1.3.6.4.1.714.1.2.3.6)
-- wbt3DhcpUpdateInfo Group (1.3.6.4.1.714.1.2.3.6.2)
--
-- Implementation of the wbt3DhcpUpdateInfo Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3DUpInfoNum OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rom images reside in the terminal currently, include main & application"
::={wbt3DhcpUpdateInfo 1}
wbt3DUpInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3DUpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of build info for each rom image, number of entries
is given by the value of wbt3DUpInfoNum"
::={wbt3DhcpUpdateInfo 2}
wbt3DUpInfoEntry OBJECT-TYPE
SYNTAX wbt3DUpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A rom image present in this terminal"
INDEX {wbt3DUpInfoIndex}
::={wbt3DUpInfoTable 1}
wbt3DUpInfoEntry ::=
SEQUENCE {
wbt3DUpInfoIndex
INTEGER,
wbt3DUpBuildNum
DisplayString,
wbt3DUpOEMBuildNum
DisplayString,
wbt3DUpModBuildDate
DisplayString
}
wbt3DUpInfoIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for this rom image. Its value ranges between
1 and the value of wbt3DUpInfoNum.."
::={wbt3DUpInfoEntry 1}
wbt3DUpBuildNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Build number of the updated ROM image"
::={wbt3DUpInfoEntry 2}
wbt3DUpOEMBuildNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Build number of the updated ROM image for OEM"
::={wbt3DUpInfoEntry 3}
wbt3DUpModBuildDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date that update image was last modified"
::={wbt3DUpInfoEntry 4}
wbt3DUpOEMBuildDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date that update image was last modified for OEM"
::={wbt3DUpInfoEntry 5}
-- ****************************************************************************
-- the wbt3CustomFields Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3CustomFields Group (1.3.6.4.1.714.1.2.3.7)
--
-- Implementation of the wbt3CustomFields Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3CustomField1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"First custom field"
::={wbt3CustomFields 1}
wbt3CustomField2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Second custom field"
::={wbt3CustomFields 2}
wbt3CustomField3 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Third custom field"
::={wbt3CustomFields 3}
-- ****************************************************************************
-- the wbt3Administration Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Administration Group (1.3.6.4.1.714.1.2.3.8)
--
-- Implementation of the wbt3Administration Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
-- group in wbt3Administration
wbt3UpDnLoad OBJECT IDENTIFIER ::= {wbt3Administration 1}
wbt3Action OBJECT IDENTIFIER ::= {wbt3Administration 2}
wbt3FTPsetting OBJECT IDENTIFIER ::= {wbt3Administration 3}
wbt3SNMPupdate OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Terminal firmware upgrade using SNMP.
Yes = SNMP update enable,
No = SNMP update disable."
::={wbt3Administration 4}
wbt3DHCPupdate OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Terminal firmware upgrade using DHCP.
Yes = DHCP automatic update enable,
No = DHCP automatic update disable."
::={wbt3Administration 5}
-- ****************************************************************************
-- the wbt3UpDnLoad Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Administration Group (1.3.6.4.1.714.1.2.3.8)
-- wbt3UpDnLoad Group (1.3.6.4.1.714.1.2.3.8.1)
--
-- Implementation of the wbt3UpDnLoad Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3UpDnLoadNum OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of entries in the Up/Download table,
Maximum value is 5"
::={wbt3UpDnLoad 1}
wbt3UpDnLoadTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3UpDnLoadEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of files to be upload or download"
::={wbt3UpDnLoad 2}
wbt3AcceptReq OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicate whether ThinClient is ready to accept SNMP up/down load request"
::={wbt3UpDnLoad 3}
wbt3SubmitLoadJob OBJECT-TYPE
SYNTAX INTEGER {
NotReady(0),
Ready(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to Ready(1) will kick off the up/download process
specified in wbt3UpDnLoadTable"
::={wbt3UpDnLoad 4}
wbt3UpDnLoadEntry OBJECT-TYPE
SYNTAX wbt3UpDnLoadEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An upload or download request entry from server"
INDEX {wbt3UpDnLoadIndex}
::={wbt3UpDnLoadTable 1}
wbt3UpDnLoadEntry ::=
SEQUENCE {
wbt3UpDnLoadIndex
INTEGER,
wbt3UpDnLoadId
DisplayString,
wbt3UpDnLoadOp
INTEGER,
wbt3UpDnLoadSrcFile
DisplayString,
wbt3UpDnLoadDstFile
DisplayString,
wbt3UpDnLoadFileType
DisplayString,
wbt3UpDnLoadProtocol
INTEGER,
wbt3UpDnLoadFServer
DisplayString,
wbt3UpDnLoadTimeFlag
INTEGER
}
wbt3UpDnLoadIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A unique value for the request entry. Its value
ranges between 1 and the value of wbt3UpDnLoadNum."
::={wbt3UpDnLoadEntry 1}
wbt3UpDnLoadId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An id number for this up/download request.
This number is used to match with WBT private trap which
will be sent to the server upon done with this up/download request."
::={wbt3UpDnLoadEntry 2}
wbt3UpDnLoadOp OBJECT-TYPE
SYNTAX INTEGER {
Upload(0),
Download(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0=an upload request;1=a download request"
::={wbt3UpDnLoadEntry 3}
wbt3UpDnLoadSrcFile OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The path and file name for source file to be up/downloaded."
::={wbt3UpDnLoadEntry 4}
wbt3UpDnLoadDstFile OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The path and file name where the up/downloaded file will be stored."
::={wbt3UpDnLoadEntry 5}
wbt3UpDnLoadFileType OBJECT-TYPE
SYNTAX INTEGER {
Binary(0),
ASCII(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0=binary;1=ascii"
::={wbt3UpDnLoadEntry 6}
wbt3UpDnLoadProtocol OBJECT-TYPE
SYNTAX INTEGER {
ftp(0),
tftp(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0=ftp, 1=tftp"
::={wbt3UpDnLoadEntry 7}
wbt3UpDnLoadFServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The file server IP address (or name) to/from which the file is up/downloaded."
::={wbt3UpDnLoadEntry 8}
wbt3UpDnLoadTimeFlag OBJECT-TYPE
SYNTAX INTEGER {
Immediate(0) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0=execute request immediately"
::={wbt3UpDnLoadEntry 9}
-- ****************************************************************************
-- the wbt3Action Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Administration Group (1.3.6.4.1.714.1.2.3.8)
-- wbt3Action Group (1.3.6.4.1.714.1.2.3.8.2)
--
-- Implementation of the wbt3Action Group is mandatory for all ThinClient2
-- ****************************************************************************
wbt3RebootRequest OBJECT-TYPE
SYNTAX INTEGER {
NoReboot(0),
RebootNow(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this object to RebootNow to kick off a reboot on the thinclient"
::={wbt3Action 1}
wbt3ResetToFactoryDefault OBJECT-TYPE
SYNTAX INTEGER {
NoReset(0),
ResetNow(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset the terminal to factory-default settings.
The terminal will be reboot after ResetNow is set."
::={wbt3Action 2}
-- ****************************************************************************
-- the wbt3FTPsetting Group
--
-- The wyse Group (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Administration Group (1.3.6.4.1.714.1.2.3.8)
-- wbt3FTPsetting Group (1.3.6.4.1.714.1.2.3.8.3)
--
-- Implementation of the wbt3FTPsetting Group is mandatory for all ThinClient2
-- ****************************************************************************
wbt3ServerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"File server name or IP address where the ROM images are located."
::={wbt3FTPsetting 1}
wbt3Directory OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Directory where the ROM images are located."
::={wbt3FTPsetting 2}
wbt3UserID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User identification to login to the file server."
::={wbt3FTPsetting 3}
wbt3Password2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User password to login to the file server."
::={wbt3FTPsetting 4}
wbt3SavePassword OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Yes = to save the password permanently,
No = do not save the password."
::={wbt3FTPsetting 5}
wbt3InfoLocation OBJECT-TYPE
SYNTAX INTEGER {
UseLocalinfo(0),
UseDHCPinfo(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UseDHCPinfo = ServerName and Directory will be provided by DHCP server,
UseLocalinfo = ServerName and Directory will be provided using local settings."
::={wbt3FTPsetting 6}
wbt3Security OBJECT IDENTIFIER ::= {wbt3Administration 7}
-- ****************************************************************************
-- the wbt3Security Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Administration Group (1.3.6.4.1.714.1.2.3.8)
-- wbt3Security Group (1.3.6.4.1.714.1.2.3.8.7)
--
-- Implementation of the wbt3Security Group is mandatory for all wbt3
-- products with SNMP agents which supports the hpWinTerm MIB
-- ****************************************************************************
wbt3SecurityEnable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This group box is used to enable terminal security and connection configuration access.
selecting enable terminal security, and deactivate the Hide Configure Tab function.
By default this function is disabled"
::={wbt3Security 1}
wbt3HideConfigTab OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This function hides the Configure tab in the Winterm Connections Manager.
By default this function is not activated."
::={wbt3Security 2}
wbt3FailOverEnable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Failover is a connection feature that is enabled using the Security properties sheet.
Disabling this function activates the PingBeforeConnect function.
By default this function is enabled."
::={wbt3Security 3}
wbt3MultipleConnect OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allow multiple connections.
Select Yes to enable. By default this function is disabled."
::={wbt3Security 4}
wbt3PingBeforeConnect OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Yes to enable. By default this function is deactivated.
When FailOver is checked, PingBeforeConnect is grayed out,
since it is implied that Ping is always performed before
a connection is made."
::={wbt3Security 5}
wbt3Verbose OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Yes to enable the Verbose connection function. By default the box is disabled.
During the FailOver operation, user can see the status via a log window
by checking the Verbose checkbox.
The log window will show everything from first connection onward."
::={wbt3Security 6}
wbt3AutoLoginEnable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The AutoLogin function is an automatic login function that does not use
a dialog box as a prompt to log you back into your terminal.
Whether you restart or log off, the AutoLogin dialog box displays,
counts five seconds, then returns you to the Winterm Connections Manager. "
::={wbt3Security 7}
wbt3AutoLoginUserName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This field is activated by enabling AutoLogin Enable.
By default the field is blank."
::={wbt3Security 8}
wbt3SingleButtonConnect OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Yes to enable the function. By default the function is not activated."
::={wbt3Security 9}
wbt3AutoFailRecovery OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Yes to enable the function. By default the function is activated."
::={wbt3Security 10}
-- ****************************************************************************
-- the wbt3TrapsInfo Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3TrapsInfo Group (1.3.6.4.1.714.1.2.3.9)
--
-- Implementation of the wbt3TrapsInfo Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3TrapStatus OBJECT-TYPE
SYNTAX INTEGER {
LS_DONE(0),
LS_DONE_SAMEVERSION(1),
LS_NOTREADY(2),
LS_FAIL_SHUTDOWN(3),
LS_FAIL_NOUPD(4),
LS_FAIL_DNLD_BLOCKED(5),
LS_FAIL_FILENOTFOUND(6),
LS_FAIL_DIR(7),
LS_FAIL_UPLD_BLOCKED(8),
LS_FAIL_NOSERV(9),
LS_FAIL_PROT(10),
LS_FAIL_NOMEM(11),
LS_FAIL_NORESOURCE(12),
LS_FAIL_RESOLVENAME(13),
LS_FAIL_NOTBUNDLE(14),
LS_FAIL_CHECKSUM(15),
LS_FAIL_FLASHERROR(16),
LS_FAIL_DNLD_FLASH(17),
LS_FAIL_USERCANCEL(18),
LS_FAIL_NORFLASH(19),
LS_FAIL_PROTNSUPPORT(20),
LS_FAIL_PARSEREG(21),
LS_FAIL_PARSEREG_VERINCOMP(22),
LS_FAIL_PARSEREG_PLATFINCOMP(23),
LS_FAIL_PARSEREG_OSINCOMP(24),
LS_FAIL_RESET_DEFAULTFACTORY(25),
LS_FAIL_PARAMINIFILENOTFOUND(26),
LS_INVALID_BOOTSTRAP(27),
LS_FAIL_BADKEY(28)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current trap status information."
::={wbt3TrapsInfo 1}
wbt3TrapReqId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The SNMP up/down load request Id associated with current trap"
::={wbt3TrapsInfo 2}
wbt3TrapServers OBJECT IDENTIFIER ::= {wbt3TrapsInfo 3}
-- ****************************************************************************
-- the wbt3TrapServers Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3TrapsInfo Group (1.3.6.4.1.714.1.2.3.9)
-- wbt3TrapServers Group (1.3.6.4.1.714.1.2.3.9.3)
--
-- Implementation of the wbt3TrapServers Group is mandatory for all wbt3
-- ****************************************************************************
wbt3TrapServer1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Server name or IP address where the trap messages will be sent."
::={wbt3TrapServers 1}
wbt3TrapServer2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Server name or IP address where the trap messages will be sent."
::={wbt3TrapServers 2}
wbt3TrapServer3 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Server name or IP address where the trap messages will be sent."
::={wbt3TrapServers 3}
wbt3TrapServer4 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Server name or IP address where the trap messages will be sent."
::={wbt3TrapServers 4}
-- ****************************************************************************
-- the MibRev group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3MibRev Group (1.3.6.4.1.714.1.2.3.10)
--
-- Implementation of the wbt3MibRev group is mandatory for all SNMP agents supporting
-- the wyse MIB
--
-- An SNMP agent conforming to this document will return
-- a wbt3MibRevMajor of one(1) and a wbt3MibRevMinor of eight(8)
-- ****************************************************************************
wbt3MibRevMajor OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The major revision level of the MIB
The number for current version."
::={wbt3MibRev 1}
wbt3MibRevMinor OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minor revision level of the MIB
The number for current version is 8."
::={wbt3MibRev 2}
-- ****************************************************************************
-- the wbt3Network group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Network Group (1.3.6.4.1.714.1.2.3.11)
--
-- Implementation of the wbt3Network Group is mandatory for all ThinClient2
-- ****************************************************************************
wbt3NetworkNum OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of entries in the Network table."
::={wbt3Network 1}
wbt3NetworkTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3NetworkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of network configuration, number of entries
is given by the value of wbt3NetworkNum."
::={wbt3Network 2}
wbt3NetworkEntry OBJECT-TYPE
SYNTAX wbt3NetworkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A Network configuration presents in this terminal."
INDEX {wbt3NetworkIndex}
::={wbt3NetworkTable 1}
wbt3NetworkEntry ::=
SEQUENCE {
wbt3NetworkIndex
INTEGER,
wbt3DHCPEnable
INTEGER,
wbt3NetworkAddress
DisplayString,
wbt3SubnetMask
DisplayString,
wbt3Gateway
DisplayString,
wbt3dnsEnable
INTEGER,
wbt3defaultDomain
DisplayString,
wbt3primaryDNSserverIPaddress
DisplayString,
wbt3secondaryDNSserverIPaddress
DisplayString,
wbt3winsEnable
INTEGER,
wbt3primaryWINSserverIPaddress
DisplayString,
wbt3secondaryWINSserverIPaddress
DisplayString,
wbt3NetworkSpeed
INTEGER,
wbt3NetworkProtocol
INTEGER
}
wbt3NetworkIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for the request entry. Its value
ranges between 1 and the value of wbt3NetworkIndex."
::={wbt3NetworkEntry 1}
wbt3dhcpEnable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the terminal acquires its network parameters
through DHCP or uses the static parameters provided."
::={wbt3NetworkEntry 2}
wbt3NetworkAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address persents in this terminal."
::={wbt3NetworkEntry 3}
wbt3SubnetMask OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subnet Mask presents in this terminal."
::={wbt3NetworkEntry 4}
wbt3Gateway OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Default gateway IP address."
::={wbt3NetworkEntry 5}
wbt3dnsEnable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the terminal uses DNS to translate names to IP addresses."
::={wbt3NetworkEntry 6}
wbt3defaultDomain OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the domain in which the terminal belongs."
::={wbt3NetworkEntry 7}
wbt3primaryDNSserverIPaddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the primary name server."
::={wbt3NetworkEntry 8}
wbt3secondaryDNSserverIPaddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the secondary name server."
::={wbt3NetworkEntry 9}
wbt3winsEnable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the terminal uses WINS to resolve to IP addresses."
::={wbt3NetworkEntry 10}
wbt3primaryWINSserverIPaddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the primary name server."
::={wbt3NetworkEntry 11}
wbt3secondaryWINSserverIPaddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the secondary name server."
::={wbt3NetworkEntry 12}
wbt3NetworkSpeed OBJECT-TYPE
SYNTAX INTEGER {
Auto-Detect(0),
HalfDuplex-10Mbs(9),
FullDuplex-10Mbs(8),
HalfDuplex-100Mbs(7),
FullDuplex-100Mbs(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the Network speed connection.(Not available for Mars)"
::={wbt3NetworkEntry 17}
wbt3NetworkProtocol OBJECT-TYPE
SYNTAX INTEGER {
TCP-IP(0),
Unknown(256)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates network protocol used."
::={wbt3NetworkEntry 20}
-- ****************************************************************************
-- the wbt3Apps group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Apps Group (1.3.6.4.1.714.1.2.3.12)
--
-- Implementation of the wbt3Apps Group is mandatory for all ThinClient2
-- ****************************************************************************
wbt3RDPencryption OBJECT-TYPE
SYNTAX INTEGER {
Enable(0),
Disable(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable the RPD encryption."
::={wbt3Apps 1}
wbt3VirtualPortServerIPaddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify the virtual port server address."
::={wbt3Apps 2}
wbt3com1Share OBJECT-TYPE
SYNTAX INTEGER {
Yes(0),
No(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable COM1 share."
::={wbt3Apps 3}
wbt3com2Share OBJECT-TYPE
SYNTAX INTEGER {
Yes(0),
No(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable COM2 share."
::={wbt3Apps 4}
wbt3parallelShare OBJECT-TYPE
SYNTAX INTEGER {
Yes(0),
No(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable parallel share port."
::={wbt3Apps 5}
ICADefaultHotkeys OBJECT-TYPE
SYNTAX SEQUENCE OF DefaultHotkeysEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ICA Client Default HotKeys settings."
::={wbt3Apps 6}
DefaultHotkeysEntry OBJECT-TYPE
SYNTAX DefaultHotkeysEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Default HotKeys entry."
::={ICADefaultHotkeys 1}
DefaultHotkeysEntry ::=
SEQUENCE {
ICAStatusDialog
INTEGER,
ICAStatusDialog2
INTEGER,
ICACloseRemoteApplication
INTEGER,
ICACloseRemoteApplication2
INTEGER,
ICAtoggleTitleBar
INTEGER,
ICAtoggleTitleBar2
INTEGER,
ICActrlAltDel
INTEGER,
ICActrlAltDel2
INTEGER,
ICActrlEsc
INTEGER,
ICActrlEsc2
INTEGER,
ICAaltEsc
INTEGER,
ICAaltEsc2
INTEGER,
ICAaltTab
INTEGER,
ICAaltTab2
INTEGER,
ICAaltBackTab
INTEGER,
ICAaltBackTab2
INTEGER
}
ICAStatusDialog OBJECT-TYPE
SYNTAX INTEGER {
Ctrl(0),
Shift(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 1}
ICAStatusDialog2 OBJECT-TYPE
SYNTAX INTEGER { Key0(0),
Key1(1),
Key2(2),
Key3(3),
Key4(4),
Key5(5),
Key6(6),
Key7(7),
Key8(8),
Key9(9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 2}
ICACloseRemoteApplication OBJECT-TYPE
SYNTAX INTEGER {
Ctrl(0),
Shift(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 3}
ICACloseRemoteApplication2 OBJECT-TYPE
SYNTAX INTEGER { Key0(0),
Key1(1),
Key2(2),
Key3(3),
Key4(4),
Key5(5),
Key6(6),
Key7(7),
Key8(8),
Key9(9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 4}
ICAtoggleTitleBar OBJECT-TYPE
SYNTAX INTEGER {
Ctrl(0),
Shift(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 5}
ICAtoggleTitleBar2 OBJECT-TYPE
SYNTAX INTEGER { Key0(0),
Key1(1),
Key2(2),
Key3(3),
Key4(4),
Key5(5),
Key6(6),
Key7(7),
Key8(8),
Key9(9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 6}
ICActrlAltDel OBJECT-TYPE
SYNTAX INTEGER {
Ctrl(0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 7}
ICActrlAltDel2 OBJECT-TYPE
SYNTAX INTEGER { Key0(0),
Key1(1),
Key2(2),
Key3(3),
Key4(4),
Key5(5),
Key6(6),
Key7(7),
Key8(8),
Key9(9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 8}
ICActrlEsc OBJECT-TYPE
SYNTAX INTEGER {
Ctrl(0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 9}
ICActrlEsc2 OBJECT-TYPE
SYNTAX INTEGER { Key0(0),
Key1(1),
Key2(2),
Key3(3),
Key4(4),
Key5(5),
Key6(6),
Key7(7),
Key8(8),
Key9(9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 10}
ICAaltEsc OBJECT-TYPE
SYNTAX INTEGER {
Ctrl(0),
Shift(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 11}
ICAaltEsc2 OBJECT-TYPE
SYNTAX INTEGER { Key0(0),
Key1(1),
Key2(2),
Key3(3),
Key4(4),
Key5(5),
Key6(6),
Key7(7),
Key8(8),
Key9(9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 12}
ICAaltTab OBJECT-TYPE
SYNTAX INTEGER {
Ctrl(0),
Shift(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 13}
ICAaltTab2 OBJECT-TYPE
SYNTAX INTEGER { Key0(0),
Key1(1),
Key2(2),
Key3(3),
Key4(4),
Key5(5),
Key6(6),
Key7(7),
Key8(8),
Key9(9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 14}
ICAaltBackTab OBJECT-TYPE
SYNTAX INTEGER {
Ctrl(0),
Shift(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 15}
ICAaltBackTab2 OBJECT-TYPE
SYNTAX INTEGER { Key0(0),
Key1(1),
Key2(2),
Key3(3),
Key4(4),
Key5(5),
Key6(6),
Key7(7),
Key8(8),
Key9(9) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ICAStatusDialog"
::={DefaultHotkeysEntry 16}
-- ****************************************************************************
-- the wbt3Connections group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Connections Group (1.3.6.4.1.714.1.2.3.13)
--
-- Implementation of the wbt3Connections Group is mandatory for all ThinClient
-- ****************************************************************************
wbt3ConnectionsTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3ConnectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of connection entries. The number of entries is the number of existing connections
plus one. The last entry is a dummy entry reserved for new connection creation.
wbt3ConnectionName for this dummy entry is 'Not Defined'."
::={wbt3Connections 2}
wbt3ConnectionEntry OBJECT-TYPE
SYNTAX wbt3ConnectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A connection entry containing objects describing this connection.
wbt3ConnectionName is the instance identifier for wbt3ConnectionEntry"
INDEX {wbt3ConnectionName}
::={wbt3ConnectionsTable 1}
wbt3ConnectionEntry ::=
SEQUENCE {
wbt3ConnectionName
DisplayString,
wbt3ConnectionType
INTEGER,
wbt3ConnectionEntryStatus
INTEGER
}
wbt3ConnectionName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the connection. This object is served as instance identifier for the connection entry.
Therefore value for this object must be unique among all entries. Maximum length depends on wbt3ConnectionType.
(37 for RDP wbt3ConnectionType; 32 for ICA wbt3ConnectionType;
42 for TEC wbt3ConnectionType; 20 for DialUp wbt3ConnectionType)"
::={wbt3ConnectionEntry 2}
wbt3ConnectionType OBJECT-TYPE
SYNTAX INTEGER {
RDP(0),
ICA(1),
TEC(2),
DialUp(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of the connection.
This object can be modified when the associated wbt3ConnectionEntryStatus is notInService. "
::={wbt3ConnectionEntry 3}
wbt3ConnectionEntryStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
notInService(2),
notReady(3),
createAndGo(4),
createAndWait(5),
destroy(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Status of this connection entry. This object is used to manage the creation and deletion
of the wbt3ConnectionEntry. State machine for this object is compliant to RFC1903, definition
of textual conventions for RowStatus. This object may not be set to 'active' unless the
wbt3ConnectionName is set.
active - this is an existing connection saved in permanent storage. Values of fields within this
table entry are not allowed to modified while it is active. To modify fields within this table
entry, take the entry to 'notInService' state first.
notInService - this is a connection entry exists in the thinclient's temporary memory, but is
unavailable for use by the thinclient device. Entry must be put in this state before modification
to other fields (except wbt3ConnectionName) can be made. Changes to wbt3ConnectionName is NOT
allowed. To modify the name of an existing connection, delete the connection by setting
wbt3ConnectionEntryStatus to 'destroy', then create a new connection with the new name by following
the description for status 'notReady', 'createAndGo' or 'createAndWait' as specified below.
A management device has to set the wbt3ConnectionEntryStatus to 'active' to activate the
connection entry. Entries remaining in notInService state for an excessive period of time will
be removed to free up resource in the thinclient device. Entries in this state will not be retained
after reboot.
notReady - this is a dummy connection defined to facilitate creation of new entry.
An administrator can create a new connection by modifying wbt3ConnectionName of this entry to
a name which does not currently exist in wbt3ConnectionsTable. This will put the entry
in notInService state. An administrator can then put the connection in permanent storage by changing
wbt3ConnectionEntryStatus to 'active'.
Note that the assigned connection name CANNOT be an empty or 'Not Defined' string.
createAndGo - This status is supplied by a management station wishing to create a new instance
of a connection entry and to have its status automatically set to active, making it
available for use by the thinclient device. wbt3ConnectionName MUST be supplied in the same
PDU which set wbt3connectionEntryStatus to 'createAndGo'.
createAndWait - This status is supplied by a management station wishing to create a new instance
of a connection entry (but not make it immediately available for use by the thinclient device).
destroy - an administrator can delete an existing connection by setting this object of
target entry to 'destroy'."
::={wbt3ConnectionEntry 10}
wbt3RDPConnections OBJECT IDENTIFIER ::= {wbt3Connections 3}
-- ****************************************************************************
-- the wbt3RDPConnections Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3RDPConnections Group (1.3.6.4.1.714.1.2.3.13.3)
-- ****************************************************************************
wbt3RDPConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3RDPConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of connections, number of entries is the number of entries in
wbt3ConnectionTable which has wbt3ConnectionEntryStatus=active or notInService, and
wbt3ConnectionType=RDP."
::={wbt3RDPConnections 1}
wbt3RDPConnEntry OBJECT-TYPE
SYNTAX wbt3RDPConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A RDP connection entry containing objects describing this connection.
wbt3RDPConnName is the instance identifier for wbt3RDPConnEntry"
INDEX {wbt3RDPConnName}
::={wbt3RDPConnTable 1}
wbt3RDPConnEntry ::=
SEQUENCE {
wbt3RDPConnName
DisplayString,
wbt3RDPConnServer
DisplayString,
wbt3RDPConnLowSpeed
INTEGER,
wbt3RDPConnAutoLogon
INTEGER,
wbt3RDPConnUsername
DisplayString,
wbt3RDPConnDomain
DisplayString,
wbt3RDPConnStartApplication
INTEGER,
wbt3RDPConnFilename
DisplayString,
wbt3RDPConnWorkingDir
DisplayString,
wbt3RDPConnModifiable
INTEGER
}
wbt3RDPConnName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of the RDP connection. This object is served as instance identifier for the RDPConnEntry.
Value for this object is unique among all entries."
::={wbt3RDPConnEntry 1}
wbt3RDPConnServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Host server name or IP address the RDP Client connects to. Maximum length is 32.
This object is modifiable only when wbt3RDPConnModifiable is 'Yes'."
::={wbt3RDPConnEntry 2}
wbt3RDPConnLowSpeed OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Using low speed connection.
This object is modifiable only when wbt3RDPConnModifiable is 'Yes'."
::={wbt3RDPConnEntry 3}
wbt3RDPConnAutoLogon OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable RDP automatic logon.
This object is modifiable only when wbt3RDPConnModifiable is 'Yes'."
::={wbt3RDPConnEntry 4}
wbt3RDPConnUsername OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify the user name to atomatically logon to host. Maximum length is 32.
This object is modifiable only when wbt3RDPConnModifiable is 'Yes'."
::={wbt3RDPConnEntry 5}
wbt3RDPConnDomain OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Domain name of host server. Maximum length is 80.
This object is modifiable only when wbt3RDPConnModifiable is 'Yes'."
::={wbt3RDPConnEntry 7}
wbt3RDPConnStartApplication OBJECT-TYPE
SYNTAX INTEGER {
Desktop(0),
Filename(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select application starts up at connection.
0 = Desktop, 2 = select File name radio button.
This object is modifiable only when wbt3RDPConnModifiable is 'Yes'."
::={wbt3RDPConnEntry 8}
wbt3RDPConnFilename OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the application to start. Maximum length is 80.
This object is modifiable only when wbt3RDPConnModifiable is 'Yes'."
::={wbt3RDPConnEntry 9}
wbt3RDPConnWorkingDir OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Application working directory. Maximum length is 80.
This object is modifiable only when wbt3RDPConnModifiable is 'Yes'."
::={wbt3RDPConnEntry 10}
wbt3RDPConnModifiable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate whether objects within this entry is modifiable currently.
Objects are modifiable if wbt3ConnectionEntryStatus of associated connection entry in
wbt3ConnectionsTable is in 'notInService'."
::={wbt3RDPConnEntry 30}
wbt3ICAConnections OBJECT IDENTIFIER ::= {wbt3Connections 4}
-- ****************************************************************************
-- the wbt3ICAConnections Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3ICAConnections Group (1.3.6.4.1.714.1.2.3.13.4)
--
-- ****************************************************************************
wbt3ICAConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3ICAConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of ICA connections, number of entries is the number of entries in
wbt3ConnectionTable which has wbt3ConnectionEntryStatus=active or notInService, and
wbt3ConnectionType=ICA."
::={wbt3ICAConnections 1}
wbt3ICAConnEntry OBJECT-TYPE
SYNTAX wbt3ICAConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A ICA connection entry containing objects describing this connection.
wbt3ICAConnName is the instance identifier for wbt3ICAConnEntry"
INDEX {wbt3ICAConnName}
::={wbt3ICAConnTable 1}
wbt3ICAConnEntry ::=
SEQUENCE {
wbt3ICAConnName
DisplayString,
wbt3ICAConnCommType
INTEGER,
wbt3ICAConnServer
DisplayString,
wbt3ICAConnCommandLine
DisplayString,
wbt3ICAConnWorkingDir
DisplayString,
wbt3ICAConnUsername
DisplayString,
wbt3ICAConnDomain
DisplayString,
wbt3ICAConnColors
INTEGER,
wbt3ICAConnDataCompress
INTEGER,
wbt3ICAConnSoundQuality
INTEGER,
wbt3ICAConnModifiable
INTEGER
}
wbt3ICAConnName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of the ICA connection. This object is served as instance identifier for the ICAConnEntry.
Value for this object is unique among all entries."
::={wbt3ICAConnEntry 1}
wbt3ICAConnCommType OBJECT-TYPE
SYNTAX INTEGER {
Network(0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Communication media this connection uses.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 2}
wbt3ICAConnServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of ICA server connect to. Maximum length is 63.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 3}
wbt3ICAConnCommandLine OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command line to be launched once this ICA connection is brought up. Maximum length is 80.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 4}
wbt3ICAConnWorkingDir OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Working Directory to be used for this ICA. Maximum length is 80.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 5}
wbt3ICAConnUsername OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User name to be used to log on to ICA server. Maximum length is 19.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 6}
wbt3ICAConnDomain OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Domain name to be used to log on to ICA server. Maximum length is 16.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 8}
wbt3ICAConnColors OBJECT-TYPE
SYNTAX INTEGER {
Colors-16(0),
Colors-256(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify 16/256 window colors.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 9}
wbt3ICAConnDataCompress OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable Data compression for this ICA session.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 10}
wbt3ICAConnSoundQuality OBJECT-TYPE
SYNTAX INTEGER {
None(0),
Low(1),
Medium(2),
High(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set sound quality for this ICA session, None to disable sound.
This object is modifiable only when wbt3ICAConnModifiable is 'Yes'."
::={wbt3ICAConnEntry 11}
wbt3ICAConnModifiable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate whether objects within this entry is modifiable currently.
Objects are modifiable if wbt3ConnectionEntryStatus of associated connection entry in
wbt3ConnectionsTable is in 'notInService'."
::={wbt3ICAConnEntry 30}
wbt3TermConnections OBJECT IDENTIFIER ::= {wbt3Connections 5}
-- ****************************************************************************
-- the wbt3TermConnections Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3TermConnections Group (1.3.6.4.1.714.1.2.3.13.5)
--
-- ****************************************************************************
wbt3TermConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3TermConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Terminal Emulation connections, number of entries is the number of entries in
wbt3ConnectionTable which has wbt3ConnectionEntryStatus=active or notInService, and
wbt3ConnectionType=TEC."
::={wbt3TermConnections 1}
wbt3TermConnEntry OBJECT-TYPE
SYNTAX wbt3TermConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A terminal emulation connection entry containing objects describing this connection.
wbt3TermConnName is the instance identifier for wbt3TermConnEntry"
INDEX {wbt3TermConnName}
::={wbt3TermConnTable 1}
wbt3TermConnEntry ::=
SEQUENCE {
wbt3TermConnName
DisplayString,
wbt3TermConnCommType
INTEGER,
wbt3TermConnServer
DisplayString,
wbt3TermConnEmuType
INTEGER,
wbt3TermVTEmuModel
INTEGER,
wbt3TermIBM3270EmuModel
INTEGER,
wbt3TermIBM5250EmuModel
INTEGER,
wbt3TermConnPortNumber
DisplayString,
wbt3TermConnTelnetName
DisplayString,
wbt3TermConnPrinterPort
INTEGER,
wbt3TermConnFormFeed
INTEGER,
wbt3TermConnAutoLineFeed
INTEGER,
wbt3TermConnModifiable
INTEGER
}
wbt3TermConnName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique name for the Terminal Emulation configuration entry. Maximum length is 42"
::={wbt3TermConnEntry 1}
wbt3TermConnCommType OBJECT-TYPE
SYNTAX INTEGER {
Network(0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Communication media this connection uses.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 2}
wbt3TermConnServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or host name of terminal server connect to. Maximum length is 60.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 3}
wbt3TermConnEmuType OBJECT-TYPE
SYNTAX INTEGER {
VT52(0),
VT100(1),
-- VT220(2),
VT400-7-Bit(3),
VT400-8-Bit(4),
Ansi-BBS(5),
Sco-Console(6),
IBM3270(7),
IBM3151(8),
IBM5250(9),
WY50(10),
WY50plus(11),
TVI910(12),
TVI920(13),
TVI925(14),
ADDS-A2(15),
HZ1500(16),
WY60(17)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Emulation mode for this connection.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 4}
wbt3TermConnVTEmuModel OBJECT-TYPE
SYNTAX INTEGER {
VT100(0),
VT101(1),
VT102(2),
VT125(3),
VT220(4),
VT240(5),
VT320(6),
VT340(7),
VT420(8),
VT131(9),
VT132(10),
Not-Applicable(256)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Terminal model uses for this connection. This field represents the VT Terminal ID.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 5}
wbt3TermConnIBM3270EmuModel OBJECT-TYPE
SYNTAX INTEGER {
IBM3278-2(0),
IBM3278-3(1),
IBM3278-4(2),
IBM3278-5(3),
IBM3278-2-E(4),
IBM3278-3-E(5),
IBM3278-4-E(6),
IBM3278-5-E(7),
IBM3279-2(8),
IBM3279-3(9),
IBM3279-4(10),
IBM3279-5(11),
IBM3287-1(12),
Not-Applicable(256)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IBM 3270 terminal emulation models.
This object is valid only when wbt3TermConnEmuType = IBM3270.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 6}
wbt3TermConnIBM5250EmuModel OBJECT-TYPE
SYNTAX INTEGER {
IBM5291-1(0),
IBM5292-2(1),
IBM5251-11(2),
IBM3179-2(3),
IBM3196-A1(4),
IBM3180-2(5),
IBM3477-FC(6),
IBM3477-FG(7),
IBM3486-BA(8),
IBM3487-HA(9),
IBM3487-HC(10),
Not-Applicable(256)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IBM 5250 terminal emulation models.
This object is valid only when wbt3TermConnEmuType = IBM5250.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 7}
wbt3TermConnPortNumber OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Telnet port number used for this connection.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 10}
wbt3TermConnTelnetName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of this telnet session. Maximum length is 39.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 11}
wbt3TermConnPrinterPort OBJECT-TYPE
SYNTAX INTEGER {
LPT1(0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Printer port assigned to this connection.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 12}
wbt3TermConnFormFeed OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Use Form Feed terminator for printing.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 13}
wbt3TermConnAutoLineFeed OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Use Auto line Feed for printing.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 14}
wbt3TermConnScript OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Script for this terminal emulation.
Script syntax:
Use back slash (\) to separate between 2 script commands,
each script command has 2 entries (Act on and Send),
Use semi column (;) to separate 2 entries.
Samples: Login;<CR> or
Login;<CR><D>\Username,<U>
Send entry syntax: C.return = <CR> Delay (2s) = <D> Line Feed = <LF>
Password = <PW> Pause (0.255) = <P> UserName = <UN>.
Maximum length is 256.
This object is modifiable only when wbt3TermConnModifiable is 'Yes'."
::={wbt3TermConnEntry 15}
wbt3TermConnModifiable OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate whether objects within this entry is modifiable currently.
Objects are modifiable if wbt3ConnectionEntryStatus of associated connection entry in
wbt3ConnectionsTable is in 'notInService'."
::={wbt3TermConnEntry 30}
-- ****************************************************************************
-- the wbt3Users Group
--
-- The wyse enterprise (1.3.6.4.1.714)
-- Product Group (1.3.6.4.1.714.1)
-- ThinClient Group (1.3.6.4.1.714.1.2)
-- wbt3 Group (1.3.6.4.1.714.1.2.3)
-- wbt3Administration Group (1.3.6.4.1.714.1.2.3.8)
-- wbt3Users Group (1.3.6.4.1.714.1.2.3.8.14)
--
-- Implementation of the wbt3UpDnLoad Group is mandatory for all ThinClient2
-- products with SNMP agents which supports the wyse MIB
-- ****************************************************************************
wbt3UsersTable OBJECT-TYPE
SYNTAX SEQUENCE OF wbt3UsersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of user accounts. The number of entries is the number of existing user accounts
plus one. The last entry is a dummy entry reserved for new user account creation.
wbt3userName for this dummy entry is 'Not Defined'."
::={wbt3Users 2}
wbt3UsersEntry OBJECT-TYPE
SYNTAX wbt3UsersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A user account entry containing objects describing this user.
wbt3userName is the instance identifier for wbt3UsersEntry"
INDEX {wbt3userName}
::={wbt3UsersTable 1}
wbt3UsersEntry ::=
SEQUENCE {
wbt3UsersStatus
INTEGER,
wbt3userName
DisplayString,
wbt3privilege
INTEGER,
wbt3password1
DisplayString,
wbt3Connection1
DisplayString,
wbt3Connection2
DisplayString,
wbt3Connection3
DisplayString,
wbt3Connection4
DisplayString,
wbt3Connection5
DisplayString,
wbt3Connection6
DisplayString,
wbt3Connection7
DisplayString,
wbt3Connection8
DisplayString,
wbt3UserPasswordChange
INTEGER
}
wbt3UsersStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
notInService(2),
notReady(3),
createAndGo(4),
createAndWait(5),
destroy(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Status of this user account entry. This object is used to manage the creation and deletion
of the wbt3UsersEntry. State machine for this object is compliant to RFC1903, definition
of textual conventions for RowStatus. This object may not be set to 'active' unless the
wbt3UserName is set.
active - this is an existing user account saved in permanent storage. Values of fields within this
table entry are not allowed to modified while it is active. To modify fields within this table
entry, take the entry to 'notInService' state first.
notInService - this is a user account entry exists in the thinclient's temporary memory, but is
unavailable for use by the thinclient device. Entry must be put in this state before modification
to other fields (except wbt3UserName) can be made. Changes to wbt3UserName is NOT
allowed. To modify the name of an existing user account, delete the user account by setting
wbt3UsersStatus to 'destroy', then create a new user account with the new name by following
the description for status 'notReady', 'createAndGo' or 'createAndWait' as specified below.
A management device has to set the wbt3UsersStatus to 'active' to activate the
user account. Entries remaining in notInService state for an excessive period of time will
be removed to free up resource in the thinclient device. Entries in this state will not be retained
after reboot.
notReady - this is a dummy user account defined to facilitate creation of new entry.
An administrator can create a new user account by modifying wbt3UserName of this entry to
a name which does not currently exist in wbt3UsersTable. This will put the entry
in notInService state. An administrator can then put the user account in permanent storage by changing
wbt3UsersStatus to 'active'.
Note that the assigned user account name CANNOT be an empty or 'Not Defined' string.
createAndGo - This status is supplied by a management station wishing to create a new instance
of a user account and to have its status automatically set to active, making it
available for use by the thinclient device. wbt3UserName MUST be supplied in the same
PDU which set wbt3UsersStatus to 'createAndGo'.
createAndWait - This status is supplied by a management station wishing to create a new instance
of a user account. (but not make it immediately available for use by the thinclient device).
destroy - an administrator can delete an existing user account by setting this object of
target entry to 'destroy'. Note that the default administrator account with name 'Administrator'
that is built in to the terminal cannot be deleted."
::={wbt3UsersEntry 2}
wbt3userName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of this user. This object is served as instance identifier for the user account entry.
Therefore value for this object must be unique among all entries. Maximum length is 20."
::={wbt3UsersEntry 3}
wbt3password1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The password for this user account. Maximum length is 20.
This object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 4}
wbt3privilege OBJECT-TYPE
SYNTAX INTEGER {
Admin(0),
User(1),
Guest(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the user has extended, normal, or
restricted rights on this terminal.
Note that the privilege of the default administrator account (with name 'Administrator') cannot
be modifed.
For all other accounts, this object can be modified only when the associated wbt3UsersStatus
is 'notInService'. "
::={wbt3UsersEntry 5}
wbt3Connection1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of a connection associated with this user. The connection name has to match the value
in wbt3ConnectionName of one of the entries in wbt3ConnectionsTable that is in an 'active' state.
That is, the connection specified has to exist and be currently activated.
Set this object to an empty string to dis-associate a connection from the user.
For a user account that has Administrator privilege, all existing connections are associated with
the user automatically. Therefore this object is not modifiable if wbt3privilege is 'Admin'.
For accounts with User or Guest privilege, this object can be modified only when the associated
wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 7}
wbt3Connection2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of a connection associated with this user. The connection name has to match the value
in wbt3ConnectionName of one of the entries in wbt3ConnectionsTable that is in an 'active' state.
That is, the connection specified has to exist and be currently activated.
Set this object to an empty string to dis-associate a connection from the user.
For a user account that has Administrator privilege, all existing connections are associated with
the user automatically. Therefore this object is not modifiable if wbt3privilege is 'Admin'.
For accounts with User or Guest privilege, this object can be modified only when the associated
wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 8}
wbt3Connection3 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of a connection associated with this user. The connection name has to match the value
in wbt3ConnectionName of one of the entries in wbt3ConnectionsTable that is in an 'active' state.
That is, the connection specified has to exist and be currently activated.
Set this object to an empty string to dis-associate a connection from the user.
For a user account that has Administrator privilege, all existing connections are associated with
the user automatically. Therefore this object is not modifiable if wbt3privilege is 'Admin'.
For accounts with User or Guest privilege, this object can be modified only when the associated
wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 9}
wbt3Connection4 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of a connection associated with this user. The connection name has to match the value
in wbt3ConnectionName of one of the entries in wbt3ConnectionsTable that is in an 'active' state.
That is, the connection specified has to exist and be currently activated.
Set this object to an empty string to dis-associate a connection from the user.
For a user account that has Administrator privilege, all existing connections are associated with
the user automatically. Therefore this object is not modifiable if wbt3privilege is 'Admin'.
For accounts with User or Guest privilege, this object can be modified only when the associated
wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 10}
wbt3Connection5 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of a connection associated with this user. The connection name has to match the value
in wbt3ConnectionName of one of the entries in wbt3ConnectionsTable that is in an 'active' state.
That is, the connection specified has to exist and be currently activated.
Set this object to an empty string to dis-associate a connection from the user.
For a user account that has Administrator privilege, all existing connections are associated with
the user automatically. Therefore this object is not modifiable if wbt3privilege is 'Admin'.
For accounts with User or Guest privilege, this object can be modified only when the associated
wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 11}
wbt3Connection6 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of a connection associated with this user. The connection name has to match the value
in wbt3ConnectionName of one of the entries in wbt3ConnectionsTable that is in an 'active' state.
That is, the connection specified has to exist and be currently activated.
Set this object to an empty string to dis-associate a connection from the user.
For a user account that has Administrator privilege, all existing connections are associated with
the user automatically. Therefore this object is not modifiable if wbt3privilege is 'Admin'.
For accounts with User or Guest privilege, this object can be modified only when the associated
wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 12}
wbt3Connection7 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of a connection associated with this user. The connection name has to match the value
in wbt3ConnectionName of one of the entries in wbt3ConnectionsTable that is in an 'active' state.
That is, the connection specified has to exist and be currently activated.
Set this object to an empty string to dis-associate a connection from the user.
For a user account that has Administrator privilege, all existing connections are associated with
the user automatically. Therefore this object is not modifiable if wbt3privilege is 'Admin'.
For accounts with User or Guest privilege, this object can be modified only when the associated
wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 13}
wbt3Connection8 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of a connection associated with this user. The connection name has to match the value
in wbt3ConnectionName of one of the entries in wbt3ConnectionsTable that is in an 'active' state.
That is, the connection specified has to exist and be currently activated.
Set this object to an empty string to dis-associate a connection from the user.
For a user account that has Administrator privilege, all existing connections are associated with
the user automatically. Therefore this object is not modifiable if wbt3privilege is 'Admin'.
For accounts with User or Guest privilege, this object can be modified only when the associated
wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 14}
wbt3AutoStart1 OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 'Yes' enable automatic launch of connection specified in wbt3Connection1
object when the user logs on. This object cannot be modified if wbt3Connection1 is empty string.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 15}
wbt3AutoStart2 OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 'Yes' enable automatic launch of connection specified in wbt3Connection2
object when the user logs on. This object cannot be modified if wbt3Connection2 is empty string.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 16}
wbt3AutoStart3 OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 'Yes' enable automatic launch of connection specified in wbt3Connection3
object when the user logs on. This object cannot be modified if wbt3Connection3 is empty string.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 17}
wbt3AutoStart4 OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 'Yes' enable automatic launch of connection specified in wbt3Connection4
object when the user logs on. This object cannot be modified if wbt3Connection4 is empty string.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 18}
wbt3AutoStart5 OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 'Yes' enable automatic launch of connection specified in wbt3Connection5
object when the user logs on. This object cannot be modified if wbt3Connection5 is empty string.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 19}
wbt3AutoStart6 OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 'Yes' enable automatic launch of connection specified in wbt3Connection6
object when the user logs on. This object cannot be modified if wbt3Connection6 is empty string.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 20}
wbt3AutoStart7 OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 'Yes' enable automatic launch of connection specified in wbt3Connection7
object when the user logs on. This object cannot be modified if wbt3Connection7 is empty string.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 21}
wbt3AutoStart8 OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 'Yes' enable automatic launch of connection specified in wbt3Connection8
object when the user logs on. This object cannot be modified if wbt3Connection8 is empty string.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 22}
wbt3UserPasswordChange OBJECT-TYPE
SYNTAX INTEGER {
No(0),
Yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates this user has privilege to change the password.
For administrator, the password change is always on and cannot be set.
For guest account, the password change is always off and cannot be set.
For user account, the password change can be set on/off.
Also, this object can be modified only when the associated wbt3UsersStatus is 'notInService'. "
::={wbt3UsersEntry 23}
-- ****************************************************************************
--
-- *** TRAPS ***
--
-- ****************************************************************************
wbt3TrapDHCPBuildMismatch TRAP-TYPE
ENTERPRISE wbt3
VARIABLES { wbt3CurBuildNum, wbt3CurOEMBuildNum, wbt3CurModBuildDate,
wbt3DUpBuildNum, wbt3DUpOEMBuildNum, wbt3DUpOEMBuildDate}
DESCRIPTION
"Firmware build number mismatch according to information
supplied by DHCP server."
::= 1
wbt3TrapDHCPUpdDone TRAP-TYPE
ENTERPRISE wbt3
VARIABLES { wbt3CurBuildNum, wbt3CurOEMBuildNum, wbt3CurModBuildDate,
wbt3DUpBuildNum, wbt3DUpOEMBuildNum, wbt3DUpOEMBuildDate}
DESCRIPTION
"Firmware upgrade initiated due to build number mismatch according
to DHCP information is done."
::= 2
wbt3TrapDHCPUpdNotComplete TRAP-TYPE
ENTERPRISE wbt3
VARIABLES { wbt3CurBuildNum, wbt3CurOEMBuildNum, wbt3CurModBuildDate,
wbt3DUpBuildNum, wbt3DUpOEMBuildNum, wbt3DUpOEMBuildDate,
wbt3TrapStatus}
DESCRIPTION
"Firmware upgrade initiated due to build number mismatch
according to DHCP information is not completed for some reason."
::= 3
wbt3TrapSNMPAccptLd TRAP-TYPE
ENTERPRISE wbt3
VARIABLES { wbt3SubmitLoadJob }
DESCRIPTION
"Ready to accept up/download request initiated by SNMP manager."
::= 4
wbt3TrapSNMPLdDone TRAP-TYPE
ENTERPRISE wbt3
VARIABLES { wbt3TrapReqId }
DESCRIPTION
"SNMP initiated up/download request is done."
::= 5
wbt3TrapSNMPLdNotComplete TRAP-TYPE
ENTERPRISE wbt3
VARIABLES { wbt3TrapReqId, wbt3TrapStatus }
DESCRIPTION
"SNMP initiated up/download request is not completed for some reason."
::= 6
wbt3TrapRebootNotComplete TRAP-TYPE
ENTERPRISE wbt3
VARIABLES { wbt3TrapStatus }
DESCRIPTION
"SNMP initiated reboot request is not completed for some reason."
::= 7
END