mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-17 16:03:04 +00:00
803 lines
24 KiB
Plaintext
Executable File
803 lines
24 KiB
Plaintext
Executable File
--
|
|
-- Title: FICON MIB
|
|
-- This is in accordance with smiv2 format.
|
|
-- Intial version 1.0
|
|
--
|
|
|
|
LINK-INCIDENT-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Integer32, OBJECT-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString
|
|
FROM SNMPv2-TC
|
|
fcSwitch
|
|
FROM Brocade-REG-MIB;
|
|
|
|
linkIncidentMIB MODULE-IDENTITY
|
|
LAST-UPDATED "0204232347Z"
|
|
ORGANIZATION "Brocade Communications Systems, Inc.,"
|
|
CONTACT-INFO "Customer Support Group
|
|
Brocade Communications Systems,
|
|
1745, Technology Drive,
|
|
San Jose, CA 95110 U.S.A
|
|
Tel: +1-408-392-6061
|
|
Fax: +1-408-392-6656
|
|
Email: support@Brocade.COM
|
|
WEB: www.brocade.com"
|
|
|
|
|
|
DESCRIPTION "The MIB module defines support for FICON in Fabos. This MIB
|
|
addresses link incident and link failure data for ficon
|
|
host/devices connected to a Brocade switch"
|
|
REVISION "200307110000Z" -- July 11, 2003
|
|
DESCRIPTION "Initial revision"
|
|
::= { fcSwitch 50 }
|
|
|
|
-- Textual conventions
|
|
|
|
FcPortID ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "x"
|
|
STATUS current
|
|
DESCRIPTION "Represents Fibre Channel Address ID, a 24-bit
|
|
value unique within the address space of a Fabric."
|
|
SYNTAX OCTET STRING (SIZE (3))
|
|
|
|
RLIRLinkFailureType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the link failure type"
|
|
SYNTAX INTEGER {
|
|
bitErrorRate(2),
|
|
lossOfSignal(3),
|
|
nOSRecognized(4),
|
|
primitiveSequenceTimeout(5),
|
|
invalidSeqForPortState(6),
|
|
loopInitializationTimeout(7),
|
|
lossOfSignalInLoopInit(8)
|
|
}
|
|
|
|
LinkWwn ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the link WWN"
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
|
|
|
|
PortType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the Port Type"
|
|
SYNTAX INTEGER {
|
|
n-port (1),
|
|
nl-port (2)
|
|
}
|
|
|
|
LinkFormat ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the frame format"
|
|
SYNTAX INTEGER {
|
|
ficon(1),
|
|
common(2)
|
|
}
|
|
|
|
RegType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the RNID Registration Type"
|
|
SYNTAX INTEGER {
|
|
conditional (1),
|
|
unconditional (2)
|
|
}
|
|
|
|
LIRRProtocol ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the LIRR Protocol"
|
|
SYNTAX INTEGER {
|
|
fcp (1),
|
|
sb2 (2)
|
|
}
|
|
|
|
RNIDTagType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "x"
|
|
STATUS current
|
|
DESCRIPTION "Represents the value of RNID Tag in Hexa Decimal format"
|
|
SYNTAX OCTET STRING (SIZE (2))
|
|
|
|
RNIDFlags ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "x"
|
|
STATUS current
|
|
DESCRIPTION "Represents the value of RNID Flag in Hexa Decimal format.
|
|
It indicates if the node is valid, not valid, or
|
|
not current. The ``Flag'' values also indi-
|
|
cate the following:
|
|
0x00 Indicates node ID of the
|
|
(storage port for RNID, switch
|
|
for SwitchRNID) is valid.
|
|
0x10 Indicates node ID of the chan-
|
|
nel port is valid.
|
|
0x20 Indicates the node ID of the
|
|
storage port is not current.
|
|
0x30 Indicates the node ID of the
|
|
channel port is not current.
|
|
0x40 Indicates the the node ID of
|
|
the (storage port for RNID,
|
|
switch for RLIR) is not valid.
|
|
0x50 Indicates the node ID of the
|
|
channel port is not valid."
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
|
|
RNIDType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the value of Type Number - Displays the type
|
|
number of the self describing node. It also describes
|
|
the machine type."
|
|
SYNTAX OCTET STRING (SIZE (6))
|
|
|
|
RNIDModel ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the value of Model Number."
|
|
SYNTAX OCTET STRING (SIZE (3))
|
|
|
|
RNIDManufacturer ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the Manufacturer name or code."
|
|
SYNTAX OCTET STRING (SIZE (3))
|
|
|
|
RNIDManufacturerPlant ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "The manufacture plant name or code."
|
|
SYNTAX OCTET STRING (SIZE (2))
|
|
|
|
RNIDSequenceNumber ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Sequence number of the self describing node."
|
|
SYNTAX OCTET STRING (SIZE (12))
|
|
|
|
RNIDParams ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "x"
|
|
STATUS current
|
|
DESCRIPTION "Represents the value of Param.
|
|
It is the incident node parameters type in
|
|
three bytes: ``0xAABBCC''. The meaning of
|
|
each byte is described below:
|
|
|
|
Byte AA:
|
|
0x00 Reserved
|
|
0x20 FC-SB-2 and updates.
|
|
0x40 Other FC-4s including FCP and
|
|
updates.
|
|
0x60 FC-SB-2 and updates and other
|
|
FC-4s including FCP and
|
|
updates.
|
|
0x80 FC-4 support not specified.
|
|
0xa0 Reserved.
|
|
0xc0 Reserved.
|
|
0xe0 Vendor specific.
|
|
|
|
Byte BB:
|
|
0x00 Unspecified class
|
|
0x01 Direct access storage device,
|
|
if it is an storage port.
|
|
Otherwise, it is not channel
|
|
to channel capable.
|
|
0x02 Magnetic tape, if it is an
|
|
storage port. Otherwise, if it
|
|
is a reserved field for a
|
|
channel port.
|
|
0x03 Input unit record, if it is an
|
|
storage port. Otherwise, it is
|
|
a reserved field for a channel
|
|
port.
|
|
0x04 Output unit, if it is an stor-
|
|
age port. Otherwise, it is a
|
|
reserved field for a channel
|
|
port.
|
|
0x05 Printer, if it is an storage
|
|
port. Otherwise, it is a
|
|
reserved field for a channel
|
|
port.
|
|
0x06 Controler, if it is an storage
|
|
port. Otherwise, it is a
|
|
reserved field for a channel
|
|
port.
|
|
0x07 Terminal - Full screen if it
|
|
is an storage port. Otherwise,
|
|
it is a reserved field for a
|
|
channel port.
|
|
|
|
0x08 Terminal - Line mode if it is
|
|
an storage port. Otherwise,
|
|
it is an emulated control unit
|
|
support only.
|
|
0x09 Reserved.
|
|
0x10 Switch, if it is a switch
|
|
device. Otherwise, it is
|
|
reserved.
|
|
0x0b 0xff Reserved.
|
|
|
|
Byte CC:
|
|
0x00 If storage CU port has regis-
|
|
tered with the switch.
|
|
0xID CHIPID if channel port has
|
|
registered with the switch.
|
|
0xPN If switch has registered with
|
|
the channel then PN represent
|
|
the FL port number."
|
|
SYNTAX OCTET STRING (SIZE (3))
|
|
|
|
-- { linkIncidentMIB 1 } is reserved for future usage.
|
|
|
|
ficonRNID OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for ficonRNID. This group contains all
|
|
RNID group objects for FICON."
|
|
::= { linkIncidentMIB 2 }
|
|
|
|
nodeRNIDTableNumEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of entries in Request Node Identification Data (RNID) table."
|
|
::= { ficonRNID 1 }
|
|
|
|
-- node RNID table
|
|
-- Node information from attached node to the switch are stored
|
|
-- in the node RNID table
|
|
|
|
nodeRNIDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NodeRNIDEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains, one entry for each Ficon RNID
|
|
node attached to a switch."
|
|
::= { ficonRNID 2 }
|
|
|
|
nodeRNIDEntry OBJECT-TYPE
|
|
SYNTAX NodeRNIDEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A entry containing the RNID information
|
|
for a ficon node"
|
|
INDEX { nodeRNIDIndex }
|
|
::= { nodeRNIDTable 1 }
|
|
|
|
NodeRNIDEntry ::= SEQUENCE {
|
|
nodeRNIDIndex
|
|
Integer32,
|
|
nodeRNIDIncidentPortWWN
|
|
LinkWwn,
|
|
nodeRNIDPID
|
|
FcPortID,
|
|
nodeRNIDFlags
|
|
RNIDFlags,
|
|
nodeRNIDType
|
|
RNIDType,
|
|
nodeRNIDModel
|
|
RNIDModel,
|
|
nodeRNIDManufacturer
|
|
RNIDManufacturer,
|
|
nodeRNIDManufacturerPlant
|
|
RNIDManufacturerPlant,
|
|
nodeRNIDSequenceNumber
|
|
RNIDSequenceNumber,
|
|
nodeRNIDConnectedPortWWN
|
|
LinkWwn,
|
|
nodeRNIDPortType
|
|
PortType,
|
|
nodeRNIDFormat
|
|
LinkFormat,
|
|
nodeRNIDTag
|
|
RNIDTagType,
|
|
nodeRNIDParams
|
|
RNIDParams
|
|
}
|
|
|
|
nodeRNIDIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into nodeRNIDTable"
|
|
::= { nodeRNIDEntry 1 }
|
|
|
|
nodeRNIDIncidentPortWWN OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port WWN for Incident port. An N-port (ficon device
|
|
or host) is an incident port"
|
|
::= { nodeRNIDEntry 2 }
|
|
|
|
nodeRNIDPID OBJECT-TYPE
|
|
SYNTAX FcPortID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "PID for an Incident port."
|
|
::= { nodeRNIDEntry 3 }
|
|
|
|
nodeRNIDFlags OBJECT-TYPE
|
|
SYNTAX RNIDFlags
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RNID flags for an Incident port."
|
|
::= { nodeRNIDEntry 4 }
|
|
|
|
nodeRNIDType OBJECT-TYPE
|
|
SYNTAX RNIDType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number associate with a node"
|
|
::= { nodeRNIDEntry 5 }
|
|
|
|
nodeRNIDModel OBJECT-TYPE
|
|
SYNTAX RNIDModel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Model number of the RNID node"
|
|
::= { nodeRNIDEntry 6 }
|
|
|
|
nodeRNIDManufacturer OBJECT-TYPE
|
|
SYNTAX RNIDManufacturer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifies the manufaturer of the node."
|
|
::= { nodeRNIDEntry 7 }
|
|
|
|
nodeRNIDManufacturerPlant OBJECT-TYPE
|
|
SYNTAX RNIDManufacturerPlant
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifies the manufacturer plant of the node."
|
|
::= { nodeRNIDEntry 8 }
|
|
|
|
nodeRNIDSequenceNumber OBJECT-TYPE
|
|
SYNTAX RNIDSequenceNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifies the sequence number of the node."
|
|
::= { nodeRNIDEntry 9 }
|
|
|
|
nodeRNIDConnectedPortWWN OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WWN of the connected port."
|
|
::= { nodeRNIDEntry 10 }
|
|
|
|
nodeRNIDPortType OBJECT-TYPE
|
|
SYNTAX PortType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port type (N, NL or virtual port) of the connected port."
|
|
::= { nodeRNIDEntry 11 }
|
|
|
|
nodeRNIDFormat OBJECT-TYPE
|
|
SYNTAX LinkFormat
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Node identification data format of the connected port."
|
|
::= { nodeRNIDEntry 12 }
|
|
|
|
nodeRNIDTag OBJECT-TYPE
|
|
SYNTAX RNIDTagType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Node identification tag of the connected port."
|
|
::= { nodeRNIDEntry 13 }
|
|
|
|
nodeRNIDParams OBJECT-TYPE
|
|
SYNTAX RNIDParams
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Node parameters of the connected port."
|
|
::= { nodeRNIDEntry 14 }
|
|
|
|
switchRNIDTableNumEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of entries in RNID table which corresponds to switch."
|
|
::= { ficonRNID 3 }
|
|
|
|
-- switchRNIDTable - This table contains the RNID info. for the
|
|
-- switch node. Normally, there will be only one entry in the table.
|
|
|
|
switchRNIDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchRNIDEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains, one entry for each switch ficon node."
|
|
::= { ficonRNID 4 }
|
|
|
|
switchRNIDEntry OBJECT-TYPE
|
|
SYNTAX SwitchRNIDEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
INDEX { switchRNIDIndex }
|
|
::= { switchRNIDTable 1 }
|
|
|
|
SwitchRNIDEntry ::= SEQUENCE {
|
|
switchRNIDIndex Integer32,
|
|
switchRNIDSwitchWWN
|
|
LinkWwn,
|
|
switchRNIDFlags
|
|
RNIDFlags,
|
|
switchRNIDType
|
|
RNIDType,
|
|
switchRNIDModel
|
|
RNIDModel,
|
|
switchRNIDManufacturer
|
|
RNIDManufacturer,
|
|
switchRNIDManufacturerPlant
|
|
RNIDManufacturerPlant,
|
|
switchRNIDSequenceNumber
|
|
RNIDSequenceNumber,
|
|
switchRNIDTag
|
|
RNIDTagType,
|
|
switchRNIDParams
|
|
RNIDParams
|
|
}
|
|
|
|
switchRNIDIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index into switchRNIDTable."
|
|
::= { switchRNIDEntry 1 }
|
|
|
|
switchRNIDSwitchWWN OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WWN of the switch."
|
|
::= { switchRNIDEntry 2 }
|
|
|
|
switchRNIDFlags OBJECT-TYPE
|
|
SYNTAX RNIDFlags
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RNID flags for switch."
|
|
::= { switchRNIDEntry 3 }
|
|
|
|
switchRNIDType OBJECT-TYPE
|
|
SYNTAX RNIDType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type Number associate with a switch."
|
|
::= { switchRNIDEntry 4 }
|
|
|
|
switchRNIDModel OBJECT-TYPE
|
|
SYNTAX RNIDModel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Model number of the RNID switch."
|
|
::= { switchRNIDEntry 5 }
|
|
|
|
switchRNIDManufacturer OBJECT-TYPE
|
|
SYNTAX RNIDManufacturer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifies the manufaturer of the switch."
|
|
::= { switchRNIDEntry 6 }
|
|
|
|
switchRNIDManufacturerPlant OBJECT-TYPE
|
|
SYNTAX RNIDManufacturerPlant
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifies the manufacturer plant of the switch."
|
|
::= { switchRNIDEntry 7 }
|
|
|
|
switchRNIDSequenceNumber OBJECT-TYPE
|
|
SYNTAX RNIDSequenceNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifies the sequence number of the switch."
|
|
::= { switchRNIDEntry 8 }
|
|
|
|
switchRNIDTag OBJECT-TYPE
|
|
SYNTAX RNIDTagType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identification tag of the switch."
|
|
::= { switchRNIDEntry 9 }
|
|
|
|
switchRNIDParams OBJECT-TYPE
|
|
SYNTAX RNIDParams
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Parameters of the switch."
|
|
::= { switchRNIDEntry 10 }
|
|
|
|
-- LIRRTable - This group contains LIRR info for each listener port.
|
|
ficonLIRR OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for ficonLIRR. This group contains all
|
|
LIRR group objects for FICON."
|
|
::= { linkIncidentMIB 3 }
|
|
|
|
lIRRTableNumEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of entries in Link Incident Record
|
|
Registration (LIRR) table"
|
|
::= { ficonLIRR 1 }
|
|
|
|
|
|
lIRRTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LIRREntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains, one entry for each LIRR incident
|
|
for an attached FICON device."
|
|
::= { ficonLIRR 2 }
|
|
|
|
lIRREntry OBJECT-TYPE
|
|
SYNTAX LIRREntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry containing LIRR information."
|
|
INDEX { lIRRIndex }
|
|
::= { lIRRTable 1 }
|
|
|
|
LIRREntry ::= SEQUENCE {
|
|
lIRRIndex
|
|
Integer32,
|
|
lIRRListenerPortWWN
|
|
LinkWwn,
|
|
lIRRListenerPID
|
|
FcPortID,
|
|
lIRRRegType
|
|
RegType,
|
|
lIRRProtocol
|
|
LIRRProtocol,
|
|
lIRRPortType
|
|
PortType,
|
|
lIRRFormat
|
|
LinkFormat
|
|
}
|
|
|
|
lIRRIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index into the LIRR table."
|
|
::= { lIRREntry 1 }
|
|
|
|
lIRRListenerPortWWN OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WWN of the Listener port."
|
|
::= { lIRREntry 2 }
|
|
|
|
lIRRListenerPID OBJECT-TYPE
|
|
SYNTAX FcPortID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "PID for the listener port."
|
|
::= { lIRREntry 3 }
|
|
|
|
lIRRRegType OBJECT-TYPE
|
|
SYNTAX RegType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Registration type - conditional or unconditional."
|
|
::= { lIRREntry 4 }
|
|
|
|
lIRRProtocol OBJECT-TYPE
|
|
SYNTAX LIRRProtocol
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Protocol type supported."
|
|
::= { lIRREntry 5 }
|
|
|
|
lIRRPortType OBJECT-TYPE
|
|
SYNTAX PortType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Attached port type."
|
|
::= { lIRREntry 6 }
|
|
|
|
lIRRFormat OBJECT-TYPE
|
|
SYNTAX LinkFormat
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Registration type - conditional or unconditional."
|
|
::= { lIRREntry 7 }
|
|
|
|
-- RLIR group - This group contains RLIR info. for each link incident"
|
|
ficonRLIR OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for ficonRLIR. This group contains all
|
|
RLIR group objects for FICON."
|
|
::= { linkIncidentMIB 4 }
|
|
|
|
rLIRTableNumEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of entries in switch Registered Link
|
|
Incident Report (RLIR) table"
|
|
::= { ficonRLIR 1 }
|
|
|
|
|
|
rLIRTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RLIREntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains, one entry for each LIRR incident
|
|
for an attached FICON device."
|
|
::= { ficonRLIR 2 }
|
|
|
|
rLIREntry OBJECT-TYPE
|
|
SYNTAX RLIREntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry containing RLIR information."
|
|
INDEX { rLIRIndex }
|
|
::= { rLIRTable 1 }
|
|
|
|
RLIREntry ::= SEQUENCE {
|
|
rLIRIndex Integer32,
|
|
rLIRIncidentPortWwn LinkWwn,
|
|
rLIRIncidentNodeWwn LinkWwn,
|
|
rLIRIncidentPortType PortType,
|
|
rLIRIncidentPID FcPortID,
|
|
rLIRIncidentPortNumber Integer32,
|
|
rLIRConnectedPortWwn LinkWwn,
|
|
rLIRConnectedNodeWwn LinkWwn,
|
|
rLIRFabricWwn LinkWwn,
|
|
rLIRLinkFailureType RLIRLinkFailureType,
|
|
--rLIRTimeStamp DisplayString(SIZE (0..64)),
|
|
rLIRTimeStamp DisplayString(SIZE(64)),
|
|
rLIRFormat LinkFormat
|
|
}
|
|
|
|
rLIRIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index into RLIR table."
|
|
::= { rLIREntry 1 }
|
|
|
|
rLIRIncidentPortWwn OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port WWN for RLIR Incident port."
|
|
::= { rLIREntry 2 }
|
|
|
|
rLIRIncidentNodeWwn OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Incident node WWN."
|
|
::= { rLIREntry 3 }
|
|
|
|
rLIRIncidentPortType OBJECT-TYPE
|
|
SYNTAX PortType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR Incident port type."
|
|
::= { rLIREntry 5 }
|
|
|
|
rLIRIncidentPID OBJECT-TYPE
|
|
SYNTAX FcPortID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR Incident PID."
|
|
::= { rLIREntry 6 }
|
|
|
|
rLIRIncidentPortNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR Incident port number.This is vendor specific
|
|
port number."
|
|
::= { rLIREntry 7 }
|
|
|
|
rLIRConnectedPortWwn OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR Connected port WWN."
|
|
::= { rLIREntry 8 }
|
|
|
|
rLIRConnectedNodeWwn OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR Connected node WWN."
|
|
::= { rLIREntry 9 }
|
|
|
|
rLIRFabricWwn OBJECT-TYPE
|
|
SYNTAX LinkWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR Fabric Wwn."
|
|
::= { rLIREntry 10 }
|
|
|
|
rLIRLinkFailureType OBJECT-TYPE
|
|
SYNTAX RLIRLinkFailureType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR Link failure type."
|
|
::= { rLIREntry 11 }
|
|
|
|
rLIRTimeStamp OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR time stamp."
|
|
::= { rLIREntry 12 }
|
|
|
|
rLIRFormat OBJECT-TYPE
|
|
SYNTAX LinkFormat
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RLIR Format."
|
|
::= { rLIREntry 13 }
|
|
|
|
-- { linkIncidentMIB 5..20 } are reserved for new mib objects in future.
|
|
|
|
-- Related traps
|
|
|
|
linkIncidentMIBTraps OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for Link Incident trap."
|
|
::= { linkIncidentMIB 21 }
|
|
|
|
linkIncidentMIBTrapPrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The Link Incident traps."
|
|
::= { linkIncidentMIBTraps 0 }
|
|
|
|
linkRNIDDeviceRegistration NOTIFICATION-TYPE
|
|
OBJECTS { nodeRNIDIndex, nodeRNIDIncidentPortWWN, nodeRNIDConnectedPortWWN }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A device registered with the switch"
|
|
::= {linkIncidentMIBTrapPrefix 1}
|
|
|
|
linkRNIDDeviceDeRegistration NOTIFICATION-TYPE
|
|
OBJECTS { nodeRNIDIndex, nodeRNIDIncidentPortWWN, nodeRNIDConnectedPortWWN }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A device de-regsitered with the switch"
|
|
::= {linkIncidentMIBTrapPrefix 2}
|
|
|
|
linkLIRRListenerAdded NOTIFICATION-TYPE
|
|
OBJECTS {lIRRListenerPortWWN, lIRRListenerPID, lIRRIndex}
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A listener for link failure incident is added"
|
|
::= {linkIncidentMIBTrapPrefix 3}
|
|
|
|
linkLIRRListenerRemoved NOTIFICATION-TYPE
|
|
OBJECTS {lIRRListenerPortWWN, lIRRListenerPID, lIRRIndex}
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A listener for link failure incident is removed"
|
|
::= {linkIncidentMIBTrapPrefix 4}
|
|
|
|
linkRLIRFailureIncident NOTIFICATION-TYPE
|
|
OBJECTS { nodeRNIDIndex, lIRRIndex, rLIRIncidentPortWwn,
|
|
rLIRConnectedPortWwn,
|
|
rLIRIndex, rLIRLinkFailureType, lIRRListenerPID }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A link failure incident has occured. The value of
|
|
lIRRIndex will be -2147483647 and lIRRListenerPID will
|
|
be 0 (zero) , if there is no listener for incident."
|
|
::= {linkIncidentMIBTrapPrefix 5}
|
|
|
|
END
|
|