mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-17 16:03:04 +00:00
3216 lines
117 KiB
Plaintext
3216 lines
117 KiB
Plaintext
-- SECTION 1: Top Level Definitions
|
|
|
|
S5-REG-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- 5000 Registration MIB Release 1.7.10
|
|
-- Revision 09/11/00
|
|
|
|
-- Copyright 1996 - 1999 Nortel Networks, Inc.
|
|
-- All rights reserved.
|
|
-- This Bay Networks SNMP Management Information Base Specification
|
|
-- (Specification) embodies Bay Networks' confidential and
|
|
-- proprietary intellectual property. Bay Networks retains all
|
|
-- title and ownership in the Specification, including any
|
|
-- revisions.
|
|
|
|
-- This Specification is supplied "AS IS," and Bay Networks makes
|
|
-- no warranty, either express or implied, as to the use,
|
|
-- operation, condition, or performance of the Specification.
|
|
|
|
-- Imports
|
|
|
|
IMPORTS
|
|
s5reg
|
|
FROM S5-ROOT-MIB;
|
|
|
|
-- Registrations for Chassis Types
|
|
-- (values for object s5ChasType)
|
|
s5ChasTypeVal OBJECT IDENTIFIER ::= { s5reg 1 }
|
|
|
|
-- Unknown or unavailable chassis type
|
|
s5ChasTypeUnknown
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 1 }
|
|
|
|
-- The chassis type for the 3000
|
|
s5ChasTypeM3000-Orig
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 2 }
|
|
|
|
-- The chassis type for the 3030
|
|
s5ChasTypeM3030
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 3 }
|
|
|
|
-- The original chassis for the 5000
|
|
s5ChasTypeM5000
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 12 }
|
|
|
|
-- The chassis type for EtherCell
|
|
s5ChasTypeM1032x
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 16 }
|
|
|
|
-- The chassis type for the 5005
|
|
s5ChasTypeM5005
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 17 }
|
|
|
|
-- The chassis types for Distributed 5000
|
|
s5ChasType5DN000
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 24 }
|
|
s5ChasType5DN002Unit-1U2 -- Model 5DN002 Hub 1.5U with 2 MDA Slots
|
|
OBJECT IDENTIFIER ::= { s5ChasType5DN000 1 }
|
|
s5ChasType5DN003Unit-2U3 -- Model 5DN003 Hub 2.5U with 3 MDA Slots
|
|
OBJECT IDENTIFIER ::= { s5ChasType5DN000 2 }
|
|
s5ChasType5DN001-08Unit-2U0 -- Model 5DN001-08 D-Day Hub 1.5U fixed config RJ-45
|
|
OBJECT IDENTIFIER ::= { s5ChasType5DN000 3 }
|
|
|
|
-- The chassis types for BayStack Ethernet
|
|
s5ChasTypeNBayStack
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 25 }
|
|
s5ChasTypeNBayStackUnit-12Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeNBayStack 1 }
|
|
s5ChasTypeNBayStackUnit-24Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeNBayStack 2}
|
|
|
|
-- The chassis types for the BayStack 100BASE-T Hub Stack
|
|
s5ChasTypeBayStack100Hub
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 27 }
|
|
s5ChasTypeBayStack100Unit-12Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack100Hub 1 }
|
|
|
|
-- The chassis type for the 3000 Fast Ethernet
|
|
s5ChasTypeM3000
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 28 }
|
|
|
|
-- Orion switch chassis type
|
|
s5ChasTypeXedia
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 29 }
|
|
|
|
-- Unused Chassis type
|
|
s5ChasTypeNotUsed
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 30 }
|
|
|
|
-- Chassis types for 28200 Ethernet Switch
|
|
s5ChasType28200
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 31 }
|
|
s5ChasType28200Unit-4slot --Model 28200 Ethernet Switch with 4 - MDA slots
|
|
OBJECT IDENTIFIER ::= { s5ChasType28200 1 }
|
|
|
|
-- Chassis types for Centillion
|
|
s5ChasTypeCent-sixSlot
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 32 }
|
|
s5ChasTypeCent-twelveSlot
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 33 }
|
|
s5ChasTypeCent-singleSlot
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 34 }
|
|
|
|
-- Chassis type for Bay Stack 301
|
|
s5ChasTypeBayStack301
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 35 }
|
|
|
|
-- Chassis type for Bay Stack Token Ring
|
|
s5ChasTypeBayStackTr
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 36 }
|
|
s5ChasTypeBayStackTrUnit-24-port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStackTr 1 }
|
|
|
|
-- Chassis type for FVC Multimedia switch
|
|
s5ChasTypeFVC10625
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 37 }
|
|
|
|
-- Chassis type for Switch Node
|
|
s5ChasTypeSwitchNode
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 38 }
|
|
|
|
-- Chassis types for BayStack302
|
|
s5ChasTypeBayStack302
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 39 }
|
|
s5ChasTypeBayStack302-ethSwitch
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack302 1 }
|
|
|
|
-- Chassis types for BayStack350
|
|
s5ChasTypeBayStack350
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 40 }
|
|
s5ChasTypeBayStack350-ethSwitch
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack350 1 }
|
|
|
|
-- The chassis types for BayStack150 Ethernet
|
|
s5ChasTypeBayStack150
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 41 }
|
|
s5ChasTypeBayStack150MasterUnit-24Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack150 1 }
|
|
s5ChasTypeBayStack150MasterUnit-12Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack150 2 }
|
|
s5ChasTypeBayStack150SlaveUnit-24Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack150 3 }
|
|
s5ChasTypeBayStack150SlaveUnit-12Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack150 4 }
|
|
|
|
--The chassis type for C50N switch
|
|
s5ChasTypeC50N
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 42 }
|
|
--The chassis type for C50T switch
|
|
s5ChasTypeC50T
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 43 }
|
|
|
|
-- Chassis type for BayStacks 303 and 304
|
|
s5ChasTypeBayStack303-304
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 44 }
|
|
|
|
-- The chassis types for BayStack200 Ethernet
|
|
s5ChasTypeBayStack200
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 45 }
|
|
s5ChasTypeBayStack200NMMHostUnit-12TxPort
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack200 1 }
|
|
s5ChasTypeBayStack200NMMHostUnit-12Tx1FxPort
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack200 2 }
|
|
s5ChasTypeBayStack200HostUnit-24Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack200 3 }
|
|
s5ChasTypeBayStack200HostUnit-12Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack200 4 }
|
|
|
|
-- The chassis types for BayStack250 10/100BASE-T Hub
|
|
s5ChasTypeBayStack250
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 46 }
|
|
s5ChasTypeBayStack250NMMHostUnit-12TxPort
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack250 1 }
|
|
s5ChasTypeBayStack250HostUnit-24Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack250 2 }
|
|
s5ChasTypeBayStack250HostUnit-12Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack250 3 }
|
|
s5ChasTypeBayStack250NMMHostUnit-24Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack250 4 }
|
|
s5ChasTypeBayStack254HostUnit-12Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack250 5 }
|
|
s5ChasTypeBayStack255HostUnit-24Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack250 6 }
|
|
|
|
-- The chassis types for stackProbes RMON probes
|
|
|
|
s5ChasTypeStackProbe
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 47 }
|
|
|
|
s5ChasTypeStackProbeOgp -- OGP Probes
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe 1 }
|
|
|
|
s5ChasTypeStackProbeOgpEth -- OGP Ethernet
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgp 1 }
|
|
s5ChasTypeStackProbeOgpEth-1Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpEth 1 }
|
|
s5ChasTypeStackProbeOgpEth-2Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpEth 2 }
|
|
s5ChasTypeStackProbeOgpEth-4Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpEth 4 }
|
|
|
|
s5ChasTypeStackProbeOgpTr -- OGP Token Ring
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgp 2 }
|
|
s5ChasTypeStackProbeOgpTr-1Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpTr 1 }
|
|
s5ChasTypeStackProbeOgpTr-2Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpTr 2 }
|
|
|
|
s5ChasTypeStackProbeOgpFddi -- OGP FDDI
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgp 3 }
|
|
s5ChasTypeStackProbeOgpFddiSas
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpFddi 1 }
|
|
s5ChasTypeStackProbeOgpFddiDas
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpFddi 2 }
|
|
|
|
s5ChasTypeStackProbeOgpFeth --OGP Fast-Ethernet
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgp 4 }
|
|
s5ChasTypeStackProbeOgpFeth-1Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpFeth 1 }
|
|
s5ChasTypeStackProbeOgpFeth-2Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbeOgpFeth 2 }
|
|
|
|
s5ChasTypeStackProbe1000 -- Series 1000 Probes (Pocket Probes)
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe 2 }
|
|
s5ChasTypeStackProbe1000Eth
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe1000 1 }
|
|
s5ChasTypeStackProbe1000Eth-1Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe1000Eth 1 }
|
|
s5ChasTypeStackProbe1000Feth
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe1000 2 }
|
|
s5ChasTypeStackProbe1000Feth-1Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe1000Feth 1 }
|
|
|
|
s5ChasTypeStackProbe2000 -- Series 2000 Probes
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe 3 }
|
|
s5ChasTypeStackProbe2000Eth
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe2000 1 }
|
|
s5ChasTypeStackProbe2000Eth-1Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe2000Eth 1 }
|
|
s5ChasTypeStackProbe2000Eth-2Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe2000Eth 2 }
|
|
s5ChasTypeStackProbe2000Eth-4Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe2000Eth 4 }
|
|
s5ChasTypeStackProbe2000Fddi
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe2000 2 }
|
|
s5ChasTypeStackProbe2000FddiSas
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe2000Fddi 1 }
|
|
s5ChasTypeStackProbe2000FddiDas
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe2000Fddi 2 }
|
|
|
|
s5ChasTypeStackProbe3000 -- Series 3000 Probes
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe 4 }
|
|
s5ChasTypeStackProbe3000Geth
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe3000 1 }
|
|
s5ChasTypeStackProbe3000Geth-1Port
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeStackProbe3000Geth 1 }
|
|
|
|
-- The chassis types for BayStack 450
|
|
s5ChasTypeBayStack450
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 48 }
|
|
s5ChasTypeBayStack450-12TxPort
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack450 1 }
|
|
s5ChasTypeBayStack450-24TxPort
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack450 2 }
|
|
|
|
-- The chassis types for BayStack 303-24T
|
|
s5ChasTypeBayStack303-24T
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 49 }
|
|
|
|
-- The chassis types for Accelar 8010
|
|
s5ChasTypeAccelar8010
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 58 }
|
|
|
|
-- The chassis types for Accelar 8006
|
|
s5ChasTypeAccelar8006
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 59 }
|
|
|
|
-- The chassis types for BayStack 670
|
|
s5ChasTypeBayStack670
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 60 }
|
|
|
|
-- The chassis types for Business Policy Switch 2000
|
|
s5ChasTypeBPS2000
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 64 }
|
|
s5ChasTypeBPS2000-24TxPort
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBPS2000 1 }
|
|
|
|
-- The chassis types for BayStack 3580
|
|
s5ChasTypeBayStack3580
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 67 }
|
|
s5ChasTypeBayStack3580-16F
|
|
OBJECT IDENTIFIER ::= {s5ChasTypeBayStack3580 1 }
|
|
|
|
-- The chassis types for BayStack 420
|
|
s5ChasTypeBayStack420
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeVal 69 }
|
|
s5ChasTypeBayStack420-24TxPort
|
|
OBJECT IDENTIFIER ::= { s5ChasTypeBayStack420 1 }
|
|
|
|
-- Registrations for Chassis Group Types
|
|
-- (values for object s5ChasGrpType)
|
|
s5ChasGrpTypeVal
|
|
OBJECT IDENTIFIER ::= { s5reg 2 }
|
|
|
|
-- Supervisor group
|
|
s5ChasGrpSup OBJECT IDENTIFIER ::= { s5ChasGrpTypeVal 1 }
|
|
|
|
-- Backplane group
|
|
s5ChasGrpBkpl OBJECT IDENTIFIER ::= { s5ChasGrpTypeVal 2 }
|
|
|
|
-- Board (or slots) group
|
|
s5ChasGrpBrd OBJECT IDENTIFIER ::= { s5ChasGrpTypeVal 3 }
|
|
|
|
-- Power supply group
|
|
s5ChasGrpPwr OBJECT IDENTIFIER ::= { s5ChasGrpTypeVal 4 }
|
|
|
|
-- Chassis level temperature sensor group
|
|
s5ChasGrpTmpSnr
|
|
OBJECT IDENTIFIER ::= { s5ChasGrpTypeVal 5 }
|
|
|
|
-- Chassis level fan group
|
|
s5ChasGrpFan OBJECT IDENTIFIER ::= { s5ChasGrpTypeVal 6 }
|
|
|
|
-- Chassis level clock group
|
|
s5ChasGrpClk OBJECT IDENTIFIER ::= { s5ChasGrpTypeVal 7 }
|
|
|
|
-- Virtual chassis unit group
|
|
s5ChasGrpUnit OBJECT IDENTIFIER ::= { s5ChasGrpTypeVal 8 }
|
|
|
|
-- Registrations for Chassis Components and Sub-components
|
|
-- (values for object s5ChasComType)
|
|
s5ChasComTypeVal
|
|
OBJECT IDENTIFIER ::= { s5reg 3 }
|
|
|
|
-- Backplanes
|
|
s5ChasComBkpl OBJECT IDENTIFIER ::= { s5ChasComTypeVal 1 }
|
|
|
|
-- Model 5000 Lower Backplane
|
|
s5ChasComBkplM5000low
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 1 }
|
|
-- Model 5000(920-209) Ethernet/Token Ring/CMB Backplane
|
|
s5ChasComBkplM5000lowCmbEthTok
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkplM5000low 4 }
|
|
|
|
-- Model 5000(920-???) Ethernet/CMB Backplane
|
|
s5ChasComBkplM5000lowCmbEth
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkplM5000low 5 }
|
|
|
|
-- Model 5000 Middle Left Backplane
|
|
s5ChasComBkplM5000midLeft
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 2 }
|
|
|
|
-- Model 5000(920-241) Full Size FDDI Backplane
|
|
s5ChasComBkplM5000midLeftFddiFull
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkplM5000midLeft 0 }
|
|
|
|
-- Model 5000 Middle Right Backplane
|
|
s5ChasComBkplM5000midRight
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 3 }
|
|
|
|
-- Model 5000 Upper Left Backplane
|
|
s5ChasComBkplM5000highLeft
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 4 }
|
|
|
|
-- Model 5000 Upper Right Backplane
|
|
s5ChasComBkplM5000highRight
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 5 }
|
|
|
|
-- Centillion Backplane
|
|
s5ChasComBkplCentATM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 6 }
|
|
|
|
-- BH/Catapult Backplane
|
|
s5ChasComBkpl2x65000BH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 7 }
|
|
s5ChasComBkpl1x125000BH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 8 }
|
|
|
|
-- C50N/C50T Backplane
|
|
s5ChasComBkplC50
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkpl 9 }
|
|
|
|
-- Backplanes (NEW names)
|
|
s5ChasComMBkpl OBJECT IDENTIFIER ::= { s5ChasComTypeVal 7 }
|
|
|
|
s5ChasComM5000Bkpl -- 5000 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 12 }
|
|
|
|
s5ChasComM5005Bkpl -- 5005 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 17 }
|
|
|
|
s5ChasComM5Dx000Bkpl -- Distributed 5000 Hub Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 24 }
|
|
s5ChasComM5DN000BkplEth3
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5Dx000Bkpl 1 }
|
|
|
|
s5ChasComMNBayStackBkpl -- BayStack Ethernet Stack
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 25 }
|
|
s5ChasComMNBayStackBkplEth3
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackBkpl 1 }
|
|
|
|
s5ChasComBayStack100Bkpl -- BayStack 100BASE-T Hub Stack
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 27 }
|
|
|
|
s5ChasComM3000Bkpl -- 3000 Chassis Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 28 }
|
|
|
|
s5ChasCom28200Bkpl -- 28200 Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 30 }
|
|
|
|
s5ChasComMBayStackTrBkpl -- BayStack Token Ring Hub Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 36 }
|
|
s5ChasComMBayStackTrBkplTr1 -- BayStack Token Ring Stack
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrBkpl 1 }
|
|
|
|
s5ChasComM3030Bkpl -- 3030 Chassis Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 39 }
|
|
|
|
s5ChasComSwitchNodeBkpl -- Switch Node Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 40 }
|
|
|
|
s5ChasComBayStack150Bkpl -- BayStack150 Ethernet Stack
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 41 }
|
|
s5ChasComBayStack150BkplEth
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack150Bkpl 1 }
|
|
|
|
s5ChasComMBayStack303-304Bkpl -- BayStack 303/304 Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 42 }
|
|
|
|
s5ChasComBayStack200Bkpl -- BayStack200 Ethernet Stack
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 43 }
|
|
s5ChasComBayStack200BkplEth
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack200Bkpl 1 }
|
|
|
|
s5ChasComBayStack250Bkpl -- BayStack250 Ethernet Stack
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 44 }
|
|
s5ChasComBayStack250BkplEth10 -- 10Mb Bkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack250Bkpl 1 }
|
|
s5ChasComBayStack250BkplEth100 -- 100Mb Bkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack250Bkpl 2 }
|
|
|
|
s5ChasComMAccelar8010Bkpl -- Accelar 8010 Chassis Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBkpl 45 }
|
|
|
|
--- Model 3000 Ethernet Backplane
|
|
s5ChasComM3000EthBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 2 }
|
|
s5ChasComM3000-1Bkpl -- Model 3000-1 Ethernet Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthBkpl 0 }
|
|
s5ChasComM3000NBkpl -- Model 3000N Multi-Segment Ethernet Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthBkpl 7 }
|
|
|
|
--- Model 3000 Ethernet/Token Ring Backplane
|
|
s5ChasComM3000EthTokBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 3 }
|
|
s5ChasComM3000-4Bkpl -- Model 3000-4 Enet/Token Ring Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthTokBkpl 4 }
|
|
s5ChasComM3000NTBkpl -- Model 3000NT Multi-Segment Enet/TR Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthTokBkpl 5 }
|
|
|
|
--- Model 3000 Ethernet/FDDI Backplane
|
|
s5ChasComM3000EthFddiBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 4 }
|
|
|
|
--- Model 3000 Ethernet/Token Ring/FDDI Backplane
|
|
s5ChasComM3000EthTokFddiBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 5 }
|
|
s5ChasComM3000-5Bkpl -- Model 3000-5 Enet/Token Ring/FDDI Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthTokFddiBkpl 2 }
|
|
s5ChasComM3000SBkpl -- Model 3000S Multi-Segment Enet/TR/FDDI Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthTokFddiBkpl 6 }
|
|
|
|
--- Model 3000 Ethernet/Token Ring Backplane with Redundant Power
|
|
s5ChasComM3000EthTokRedBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 6 }
|
|
s5ChasComM3000-4RBkpl -- Model 3000-4R Multi-Segment Enet/TR Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthTokRedBkpl 1 }
|
|
s5ChasComM3000NTRBkpl -- Model 3000NTR Multi-Segment Ethernet/TR Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthTokRedBkpl 9 }
|
|
|
|
--- Model 3000 Ethernet/Token Ring/FDDI Backplane with Redundant Power
|
|
s5ChasComM3000EthTokFddiRedBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 7 }
|
|
s5ChasComM3000-5RBkpl -- Model 3000-5R Multi-Segment Enet/TR/FDDI Backplane
|
|
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthTokFddiRedBkpl 3 }
|
|
s5ChasComM3000SRBkpl -- Model 3000SR Multi-Segment Enet/TR/FDDI Backplane
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000EthTokFddiRedBkpl 8 }
|
|
|
|
--- Model 3000 Token Ring Backplane
|
|
s5ChasComM3000TokBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 8 }
|
|
|
|
--- Model 3000CT Multi-Segment Ethernet/Token Ring/Fast Ethernet Backplane
|
|
s5ChasComM3000CTBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 9 }
|
|
|
|
--- Model 3000C Multi-Segment Ethernet/Fast Ethernet Backplane
|
|
s5ChasComM3000CBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 10 }
|
|
|
|
--- Model 3000CTR Multi-Segment Ethernet/Token Ring/Fast Ethernet Backplane
|
|
|
|
--- with Redundant Power
|
|
s5ChasComM3000CTRBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Bkpl 11 }
|
|
|
|
--- Model 3030 Ethernet Backplane
|
|
s5ChasComM3030EthBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3030Bkpl 1 }
|
|
|
|
--- Model 3030C Ethernet/Token Ring Backplane
|
|
s5ChasComM3030EthTrBkpl
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3030Bkpl 5 }
|
|
|
|
-- Model 5000 Lower Backplane
|
|
s5ChasComM5000BkplLow
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Bkpl 1 }
|
|
-- Model 5000(920-209) Ethernet/Token Ring/CMB Backplane
|
|
s5ChasComM5000BkplLowCmbEthTok
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplLow 4 }
|
|
|
|
-- Model 5000(920-303) Ethernet/CMB Backplane
|
|
s5ChasComM5000BkplLowCmbEth
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplLow 5 }
|
|
|
|
-- Model 5000 Middle Left Backplane
|
|
s5ChasComM5000BkplMidLeft
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Bkpl 2 }
|
|
|
|
-- Model 5000(920-241) Full Size FDDI Backplane
|
|
s5ChasComM5000BkplMidLeftFddiFull
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplMidLeft 0 }
|
|
|
|
-- Model 5000 Full Size 100Mbps Ethernet Backplane
|
|
s5ChasComM5000BkplMidLeftEth100MbsFull
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplMidLeft 4 }
|
|
|
|
-- Model 5000 8 slots Size 100Mbps Ethernet Backplane
|
|
s5ChasComM5000BkplMidLeftEth100Mbs
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplMidLeft 7 }
|
|
|
|
-- Model 5000 Middle Right Backplane
|
|
s5ChasComM5000BkplMidRight
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Bkpl 3 }
|
|
|
|
-- Model 5000 6 slot Size FDDI Backplane
|
|
s5ChasComBkplM5000midRightFddi
|
|
OBJECT IDENTIFIER ::= { s5ChasComBkplM5000midRight 0 }
|
|
|
|
-- Model 5000 Upper Left Backplane
|
|
s5ChasComM5000BkplHighLeft
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Bkpl 4 }
|
|
-- Model 5000 100MBps Ethernet Backplane
|
|
s5ChasComM5000BkplHighLeftEth100Mbs
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplHighLeft 4 }
|
|
-- Model 5000 Switched Packet Bus (GPB) Backplane
|
|
s5ChasComM5000BkplHighLeftSwitchedPktBusFull
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplHighLeft 5 }
|
|
-- Model 5000 ATM 16 Port Backplane
|
|
s5ChasComM5000BkplHighLeftAtm16
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplHighLeft 8 }
|
|
-- Model 5000 ATM 64 Port Backplane
|
|
s5ChasComM5000BkplHighLeftAtm64
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000BkplHighLeft 9 }
|
|
|
|
-- Model 5000 Upper Right Backplane
|
|
s5ChasComM5000BkplHighRight
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Bkpl 5 }
|
|
|
|
-- Model 5005 Lower Backplane
|
|
s5ChasComM5005BkplLow
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005Bkpl 1 }
|
|
-- Model 5005(920-305) Ethernet/Token Ring/CMB Backplane
|
|
s5ChasComM5005BkplLowCmbEthTok
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005BkplLow 4 }
|
|
|
|
-- Model 5005(920-316) Ethernet/CMB Backplane
|
|
s5ChasComM5005BkplLowCmbEth
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005BkplLow 5 }
|
|
|
|
-- Model 5005 Middle Backplane
|
|
s5ChasComM5005BkplMidLeft
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005Bkpl 2 }
|
|
-- Model 5005 Fddi Backplane
|
|
s5ChasComM5005BkplMidLeftFddi
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005BkplMidLeft 1 }
|
|
|
|
-- Model 5005 100 Mbps Backplane
|
|
s5ChasComM5005BkplMidLeftEth100Mbs
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005BkplMidLeft 5 }
|
|
|
|
-- Model 5005 Upper Backplane
|
|
s5ChasComM5005BkplHighLeft
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005Bkpl 4 }
|
|
-- Model 5005 Switched Packet Bus (GPB) Backplane
|
|
s5ChasComM5005BkplHighLeftSwitchedPktBus
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005BkplHighLeft 6 }
|
|
|
|
-- Power supplies
|
|
s5ChasComPwr OBJECT IDENTIFIER ::= { s5ChasComTypeVal 2 }
|
|
|
|
-- Model 5000 950 Watt AC Chassis Power Supply with
|
|
-- internal fan and temperature sensor
|
|
s5ChasComPwrM5000-950A
|
|
OBJECT IDENTIFIER ::= { s5ChasComPwr 0 }
|
|
s5ChasComPwrM5000-950AFan -- Internal Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComPwrM5000-950A 1 }
|
|
s5ChasComPwrM5000-950ATmpSnr -- Internal Temerature Sensor
|
|
OBJECT IDENTIFIER ::= { s5ChasComPwrM5000-950A 2 }
|
|
|
|
-- Model 5000 (721-018) 950 Watt AC Chassis Power Supply with
|
|
-- internal fan and temperature sensor
|
|
s5ChasComPwrM5000-950
|
|
OBJECT IDENTIFIER ::= { s5ChasComPwr 1 }
|
|
s5ChasComPwrM5000-950Fan -- Internal Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComPwrM5000-950 1 }
|
|
s5ChasComPwrM5000-950TmpSnr -- Internal Temerature Sensor
|
|
OBJECT IDENTIFIER ::= { s5ChasComPwrM5000-950 2 }
|
|
|
|
-- Centillion AC Chassis Power Supply
|
|
s5ChasComPwrCent OBJECT IDENTIFIER ::= { s5ChasComPwr 2 }
|
|
--Centillion 50N Chassis Power Supply
|
|
s5ChasComPwrCent50N OBJECT IDENTIFIER ::= { s5ChasComPwr 3 }
|
|
--Centillion 50T Chassis Power Supply
|
|
s5ChasComPwrCent50T OBJECT IDENTIFIER ::= { s5ChasComPwr 4 }
|
|
|
|
-- Power supplies (NEW names)
|
|
s5ChasComMPwr OBJECT IDENTIFIER ::= { s5ChasComTypeVal 8 }
|
|
|
|
s5ChasComM5000Pwr -- 5000 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 12 }
|
|
|
|
s5ChasComM5005Pwr -- 5005 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 17 }
|
|
|
|
s5ChasComM1032xPwr -- 1032x Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 16 }
|
|
|
|
s5ChasComM5DN000Pwr -- Distributed 5000 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 24 }
|
|
|
|
s5ChasComMNBayStackPwr -- BayStack Ethernet Hub Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 25 }
|
|
|
|
s5ChasComMBayStack100Pwr -- BayStack 100BASE-T Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 27 }
|
|
|
|
s5ChasComM3000Pwr -- 3000 Chassis Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 28 }
|
|
|
|
s5ChasComMBayStackTrPwr -- BayStack Token Ring Hub Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 36 }
|
|
|
|
s5ChasComM28200Pwr -- 28200 Chassis Power Supplies
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 30 }
|
|
|
|
s5ChasComMBayStack301Pwr -- BayStack 301 Chassis Power Supplies
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 31 }
|
|
|
|
s5ChasComSwitchNodePwr -- Switch Node Chassis Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 32 }
|
|
|
|
s5ChasComBayStack150Pwr -- BayStack150 Ethernet Hub Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 41 }
|
|
|
|
s5ChasComMBayStack303-304Pwr -- BayStack 303/304 Chassis Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 42 }
|
|
|
|
s5ChasComBayStack200Pwr -- BayStack200 Ethernet Hub Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 43 }
|
|
|
|
s5ChasComBayStack250Pwr -- BayStack250 Ethernet Hub Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 44 }
|
|
|
|
s5ChasComMAccelar8001Pwr -- Accelar 8010 Chassis AC Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 45 }
|
|
|
|
s5ChasComMAccelar8002Pwr -- Accelar 8010 Chassis DC Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 46 }
|
|
|
|
s5ChasComBPS2000Pwr -- BPS 2000 24 port Switch Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 47 }
|
|
|
|
s5ChasComBayStack450Pwr -- BayStack450 Switch Family Power Supply (includes BayStack 350 and 410)
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 48 }
|
|
|
|
s5ChasComBayStack3580Pwr -- BayStack3580 Gigabit Switch Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 49 }
|
|
|
|
s5ChasComBayStack420Pwr -- BayStack420 24 Port Switch Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComMPwr 50 }
|
|
|
|
-- Model 5000 (721-018) 950 Watt AC Chassis Power Supply with
|
|
-- internal fan and temperature sensor (but returning a differnt ID)
|
|
s5ChasComM5000Pwr-950A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Pwr 0 }
|
|
|
|
-- Model 5000 (721-018) 950 Watt AC Chassis Power Supply with
|
|
-- internal fan and temperature sensor
|
|
s5ChasComM5000Pwr-950
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Pwr 1 }
|
|
|
|
-- Model 5000 1400 Watt DC Chassis Power Supply
|
|
s5ChasComM5000Pwr-1400WDC
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Pwr 3 }
|
|
|
|
-- Model 5005 (721-029) 600 Watt AC Chassis Power Supply with
|
|
-- internal fan and temperature sensor
|
|
s5ChasComM5005Pwr-600
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005Pwr 1 }
|
|
|
|
-- Model 5005 900 Watt AC Chassis Power Supply
|
|
s5ChasComM5005Pwr-900WAC
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005Pwr 2 }
|
|
|
|
-- Model 5005 900 Watt DC Chassis Power Supply
|
|
s5ChasComM5005Pwr-900WDC
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005Pwr 3 }
|
|
|
|
-- Model 1032x (721-???) ??? Watt AC Chassis Power Supply
|
|
s5ChasComM1032xPwr-A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM1032xPwr 1 }
|
|
|
|
-- Stackable Redundant Power Supply Feed
|
|
s5ChasCom5DN000Pwr-RedundFeed
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN000Pwr 1 }
|
|
|
|
-- Model 5DN002 Hub 50W AC Chassis Power Supply
|
|
s5ChasComM5DN002Pwr-50W
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN000Pwr 2 }
|
|
|
|
-- Model 5DN003 Hub 110W AC Chassis Power Supply
|
|
s5ChasComM5DN003Pwr-110W
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN000Pwr 3 }
|
|
|
|
-- Stackable Redundant Power Supply Feed
|
|
s5ChasComMNBayStackPwr-RedundFeed
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackPwr 1 }
|
|
|
|
-- BayStack Ethernet Hub 50W AC Chassis Power Supply
|
|
s5ChasComMNBayStackPwr-50W
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackPwr 2 }
|
|
|
|
-- BayStack 100BASE-T Hub 110W AC Chassis Power Supply
|
|
s5ChasComMBayStack100Pwr-110W
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100Pwr 2 }
|
|
|
|
-- BayStack 100BASE-T Hub Redundant Power Supply Feed
|
|
s5ChasComMBayStack100Pwr-RedundFeed
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100Pwr 1 }
|
|
|
|
-- Model 3001 360 Watt Power Supply Module
|
|
s5ChasComM3000360Pwr
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Pwr 1 }
|
|
|
|
-- Model 3002/3002DC 460 Watt Power Supply Module
|
|
s5ChasComM3000460Pwr
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Pwr 2 }
|
|
|
|
-- Model 3003 460 Watt DC/DC Power Supply Module
|
|
s5ChasComM3003-460Pwr
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Pwr 3 }
|
|
|
|
-- Stackable Redundant Power supply Feed
|
|
s5ChasComMBayStackTrPwr-RedundFeed
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrPwr 1 }
|
|
|
|
-- Module BayStack TR (721-048-A) 150W AC/DC Chassis PowerSupply
|
|
s5ChasComMBayStackTrPwr-150W
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrPwr 2 }
|
|
|
|
-- Model 28200 Ethernet Switch 182W AC Chassis Power Supply
|
|
s5ChasComM28200Pwr-182W
|
|
OBJECT IDENTIFIER ::= { s5ChasComM28200Pwr 2 }
|
|
-- Model 28200 Ethernet Switch Redundant Power Supply Feed
|
|
s5ChasComM28200Pwr-RedundFeed
|
|
OBJECT IDENTIFIER ::= { s5ChasComM28200Pwr 1 }
|
|
|
|
-- BayStack 301 Internal Power Supply
|
|
s5ChasComMBayStack301IntPwr
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack301Pwr 1 }
|
|
-- BayStack 301 External Power Supply
|
|
s5ChasComMBayStack301ExtPwr
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack301Pwr 2 }
|
|
|
|
-- BayStack150 Ethernet Hub Chassis Power Supply
|
|
s5ChasComBayStack150MasterPwr -- Master Unit Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack150Pwr 1 }
|
|
s5ChasComBayStack150SlavePwr -- Slave unit Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack150Pwr 2 }
|
|
|
|
-- BayStack200 Ethernet Hub Chassis Power Supply
|
|
s5ChasComBayStack200MasterPwr -- Master Unit Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack200Pwr 1 }
|
|
|
|
-- BayStack250 Ethernet Hub Chassis Power Supply
|
|
s5ChasComBayStack250MasterPwr -- Master Unit Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack250Pwr 1 }
|
|
s5ChasComBayStack250SlavePwr -- Slave Unit Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack250Pwr 2 }
|
|
|
|
-- BPS 2000 24 port switch Chassis Power Supply
|
|
s5ChasComBPS2000Pwr-Main -- Unit Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComBPS2000Pwr 1 }
|
|
s5ChasComBPS2000Pwr-RedundFeed -- Redundant Power Supply Feed
|
|
OBJECT IDENTIFIER ::= { s5ChasComBPS2000Pwr 2 }
|
|
|
|
-- BayStack450 Switch Family Chassis Power Supply
|
|
s5ChasComBayStack450Pwr-Main -- Unit Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack450Pwr 1 }
|
|
s5ChasComBayStack450Pwr-RedundFeed -- Redundant Power Supply Feed
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack450Pwr 2 }
|
|
|
|
-- BayStack3580 Gigabit switch Chassis Power Supply
|
|
s5ChasComBayStack3580Pwr-Main -- Unit Power Supply
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack3580Pwr 1 }
|
|
s5ChasComBayStack3580Pwr-RedundFeed -- Redundant Power Supply Feed
|
|
OBJECT IDENTIFIER ::= {s5ChasComBayStack3580Pwr 2 }
|
|
|
|
-- Chassis level Temperature Sensors
|
|
s5ChasComTmpSnr OBJECT IDENTIFIER ::= { s5ChasComTypeVal 3 }
|
|
|
|
-- Model 5000 Chassis temperature sensor
|
|
s5ChasComTmpSnrM5000
|
|
OBJECT IDENTIFIER ::= { s5ChasComTmpSnr 1 }
|
|
|
|
-- Chassis level Temperature Sensors (NEW names)
|
|
s5ChasComMTmpSnr OBJECT IDENTIFIER ::= { s5ChasComTypeVal 9 }
|
|
s5ChasComM5000TmpSnr -- 5000 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMTmpSnr 12 }
|
|
s5ChasComM5005TmpSnr -- 5005 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMTmpSnr 17 }
|
|
|
|
-- Model 5000 (900-???) Chassis temperature sensor
|
|
s5ChasComM5000TmpSnrA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000TmpSnr 1 }
|
|
|
|
-- Model 5005 (900-???) Chassis temperature sensor
|
|
s5ChasComM5005TmpSnrA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005TmpSnr 1 }
|
|
|
|
-- Chassis level Fans
|
|
s5ChasComFan OBJECT IDENTIFIER ::= { s5ChasComTypeVal 4 }
|
|
|
|
-- Model 5000 (900-003) Chassis fan
|
|
s5ChasComFanM5000
|
|
OBJECT IDENTIFIER ::= { s5ChasComFan 1 }
|
|
|
|
-- Centillion Chassis fan
|
|
s5ChasComFanCent OBJECT IDENTIFIER ::= { s5ChasComFan 2 }
|
|
--Centillion 50N Chassis Power Supply
|
|
s5ChasComCent50NFan OBJECT IDENTIFIER ::= { s5ChasComFan 3 }
|
|
--Centillion 50T Chassis Power Supply
|
|
s5ChasComCent50TFan OBJECT IDENTIFIER ::= { s5ChasComFan 4 }
|
|
|
|
-- Chassis level Fans (NEW names)
|
|
s5ChasComMFan OBJECT IDENTIFIER ::= { s5ChasComTypeVal 10 }
|
|
|
|
s5ChasComM5000Fan -- 5000 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 12 }
|
|
|
|
s5ChasComM5005Fan -- 5005 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 17 }
|
|
|
|
s5ChasComM1032xFan -- 1032x Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 16 }
|
|
|
|
s5ChasComM5DN000Fan -- Distributed 5000 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 24 }
|
|
|
|
s5ChasComMNBayStackFan -- BayStack Ethernet Hub Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 25 }
|
|
|
|
s5ChasComMBayStack100Fan -- BayStack 100BASE-T Hub Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 27 }
|
|
|
|
s5ChasComM3000Fan -- 3000 Chassis Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 28 }
|
|
|
|
s5ChasComM28200Fan --Model 28200 Ethernet Switch Chassis Level Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 30 }
|
|
|
|
s5ChasComMBayStack301Fan -- Bay Stack 301 Chassis Level Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 31 }
|
|
|
|
s5ChasComSwitchNodeFan -- Switch Node Chassis Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 32 }
|
|
|
|
s5ChasComMBayStackTrFan -- BayStack Token Ring hub Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 36 }
|
|
|
|
s5ChasComBayStack150Fan -- BayStack150 Ethernet Hub Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 41 }
|
|
|
|
s5ChasComMBayStack303-304Fan -- Bay Stack 303/304 Chassis Level Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 42 }
|
|
|
|
s5ChasComBayStack200Fan -- BayStack200 Ethernet Hub Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 43 }
|
|
|
|
s5ChasComBayStack250Fan -- BayStack250 Ethernet Hub Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 44 }
|
|
|
|
s5ChasComMAccelar8010Fan -- Accelar 8010 Chassis Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 45 }
|
|
|
|
s5ChasComBPS2000Fan -- BPS 2000 Ethernet Switch Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 47 }
|
|
|
|
s5ChasComBayStack450Fan -- BayStack450 Switch Family Fan (includes BayStack 350 and 410)
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 48 }
|
|
|
|
s5ChasComBayStack3580Fan -- BayStack3580 Gigabit Switch Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 49 }
|
|
|
|
s5ChasComBayStack420Fan -- BayStack420 Ethernet Switch Fan
|
|
OBJECT IDENTIFIER ::= { s5ChasComMFan 50 }
|
|
|
|
-- Model 5000 (900-003) Chassis fan
|
|
s5ChasComM5000FanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Fan 1 }
|
|
|
|
-- Model 5000 (900-003) Chassis fan (real return code)
|
|
s5ChasComM5000FanAA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Fan 2 }
|
|
|
|
-- Model 5005 Chassis fan
|
|
s5ChasComM5005FanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005Fan 1 }
|
|
|
|
-- Model 1032x Chassis fan
|
|
s5ChasComM1032xFanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM1032xFan 1 }
|
|
|
|
-- Model 3000 Chassis Fan
|
|
s5ChasComM3000FanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000Fan 1 }
|
|
|
|
-- Model 5DN002 Hub 2.5 inch Fan
|
|
s5ChasComM5DN002Fan-1U
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN000Fan 1 }
|
|
|
|
-- Model 5DN003 Hub 3.5 inch Fan
|
|
s5ChasComM5DN003Fan-2U
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN000Fan 2 }
|
|
|
|
-- BayStack Ethernet Hub Fan
|
|
s5ChasComMNBayStackFanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackFan 1 }
|
|
|
|
-- BayStack 100BASE-T Hub Fan
|
|
s5ChasComMBayStack100FanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100Fan 1 }
|
|
|
|
-- BayStack Token Hub Fan Type A
|
|
s5ChasComMBayStackTrFanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrFan 1 }
|
|
-- Model 28200 Ethernet Switch Fan
|
|
s5ChasComM28200FanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM28200Fan 1 }
|
|
-- BayStack 301 Fan A
|
|
s5ChasComMBayStack301FanA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack301Fan 1 }
|
|
|
|
-- BayStack150 Ethernet Master Hub Fan
|
|
s5ChasComBayStack150MasterFan
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack150Fan 1 }
|
|
|
|
-- BayStack200 Ethernet Master Hub Fan
|
|
s5ChasComBayStack200MasterFan
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack200Fan 1 }
|
|
|
|
-- BayStack250 10/100 Ethernet Master Hub Fan
|
|
s5ChasComBayStack250MasterFan
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack250Fan 1 }
|
|
-- BayStack250 10/100 Ethernet Slave Hub Fan
|
|
s5ChasComBayStack250SlaveFan
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack250Fan 2 }
|
|
|
|
-- BPS 2000 24 port switch Fan
|
|
s5ChasComBPS2000UnitFan
|
|
OBJECT IDENTIFIER ::= { s5ChasComBPS2000Fan 1 }
|
|
|
|
-- BayStack450 Switch Family Fan
|
|
s5ChasComBayStack450UnitFan
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack450Fan 1 }
|
|
s5ChasComBayStack450RedundPwrFan
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack450Fan 2 }
|
|
|
|
-- BayStack3580 Gigabit eternet switch Fan
|
|
s5ChasComBayStack3580UnitFan
|
|
OBJECT IDENTIFIER ::= { s5ChasComBayStack3580Fan 1 }
|
|
|
|
-- Chassis level Backplane Clocks
|
|
s5ChasComClk OBJECT IDENTIFIER ::= { s5ChasComTypeVal 5 }
|
|
|
|
-- Model 5000 Backplane Clock
|
|
s5ChasComClkM5000
|
|
OBJECT IDENTIFIER ::= { s5ChasComClk 1 }
|
|
|
|
-- Chassis level Backplane Clocks (NEW names)
|
|
s5ChasComMClk OBJECT IDENTIFIER ::= { s5ChasComTypeVal 11 }
|
|
s5ChasComM5000Clk -- 5000 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMClk 12 }
|
|
s5ChasComM5005Clk -- 5005 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMClk 17 }
|
|
s5ChasComMAccelar8010Clk -- Accelar 8010 Chassis
|
|
OBJECT IDENTIFIER ::= { s5ChasComMClk 18 }
|
|
|
|
-- Model 5000 (900-???) Backplane Clock
|
|
s5ChasComM5000ClkA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5000Clk 1 }
|
|
|
|
-- Model 5005 (900-???) Backplane Clock
|
|
s5ChasComM5005ClkA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5005Clk 1 }
|
|
|
|
-- Supervisor Module and Boards in Slots
|
|
s5ChasComMod OBJECT IDENTIFIER ::= { s5ChasComTypeVal 6 }
|
|
|
|
-- Model 331X Ethernet Network Management Module
|
|
s5ChasComM331X
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 1 }
|
|
s5ChasComMDA331X
|
|
OBJECT IDENTIFIER ::= { s5ChasComM331X 255 }
|
|
|
|
-- Model 3302 Shielded Twisted Pair (STP) Host Module
|
|
s5ChasComM3302
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 2 }
|
|
s5ChasComMDA3302
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3302 255 }
|
|
|
|
-- Model 33XX Ethernet Local Bridge
|
|
s5ChasComM33XX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 3 }
|
|
s5ChasComMDA3324-ST -- Model 3324-ST Ethernet Local Bridge with FOIRL FiberPort
|
|
OBJECT IDENTIFIER ::= { s5ChasComM33XX 0 }
|
|
s5ChasComMDA3323 -- Model 3323 Ethernet Local Bridge with AUI Port
|
|
OBJECT IDENTIFIER ::= { s5ChasComM33XX 3 }
|
|
|
|
-- Model 3304-ST FOIRL Fiber Optic Host Module
|
|
s5ChasComM3304
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 4 }
|
|
s5ChasComMDA3304
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3304 255 }
|
|
|
|
-- Model 3305 Unshielded Twisted Pair (UTP) Host Module
|
|
s5ChasComM3305
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 5 }
|
|
s5ChasComMDA3305
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3305 255 }
|
|
|
|
-- Model 333X Ethernet Retiming Unit
|
|
s5ChasComM333X
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 6 }
|
|
s5ChasComMDA3334-ST -- Model 3334-ST Ethernet Retiming Unit with FOIRL
|
|
OBJECT IDENTIFIER ::= { s5ChasComM333X 0 }
|
|
s5ChasComMDA3333 -- Model 3333 Ethernet Retiming Unit with AUI
|
|
OBJECT IDENTIFIER ::= { s5ChasComM333X 3 }
|
|
|
|
-- Model 3307 10BASE-T 50 Pin Host Module
|
|
s5ChasComM3307
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 7 }
|
|
s5ChasComMDA3307
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3307 255 }
|
|
|
|
-- Model 3308 10BASE-T Host Module
|
|
s5ChasComM3308
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 8 }
|
|
s5ChasComMDA3308
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308 255 }
|
|
|
|
-- Model 3301 Thin Net Host Module
|
|
s5ChasComM3301
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 9 }
|
|
s5ChasComMDA3301
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3301 255 }
|
|
|
|
-- Model 3904 FDDI fiber host module
|
|
s5ChasComM3904
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 10 }
|
|
s5ChasComMDA3904
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3904 85 }
|
|
s5ChasComMDA3904-2SM
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3904 90 }
|
|
s5ChasComMDA3904-4SM
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3904 170 }
|
|
|
|
-- Model 3902 FDDI STP host module
|
|
s5ChasComM3902
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 11 }
|
|
s5ChasComMDA3902
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3902 255 }
|
|
|
|
-- Model 3910S Network Management Module
|
|
s5ChasComM3910S
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 12 }
|
|
s5ChasComMDA3910S -- Model 3910 Super NMM
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3910S 80 }
|
|
s5ChasComMDA3910S-SM -- Model 3910S-SM FDDI Single Mode Fiber NMM
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3910S 160 }
|
|
|
|
-- Model 331XS Ethernet Network Management Module
|
|
s5ChasComM331XS
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 14 }
|
|
s5ChasComMDA3314S -- Model 3314S Ethernet NMM with ST FORIL Fiber Port
|
|
OBJECT IDENTIFIER ::= { s5ChasComM331XS 0 }
|
|
s5ChasComMDA3313S -- Model 3313S Ethernet NMM with AUI Port
|
|
OBJECT IDENTIFIER ::= { s5ChasComM331XS 3 }
|
|
|
|
-- Model 3100R Summing Module
|
|
s5ChasComM3100R
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 15 }
|
|
s5ChasComMDA3100R
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3100R 255 }
|
|
|
|
-- Model 3502 Shielded Twisted Pair Token Ring Host Module
|
|
s5ChasComM3502
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 16 }
|
|
s5ChasComMDA3502
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3502 255 }
|
|
|
|
-- Model 3502A Shielded Twisted Pair Token Ring Host Module
|
|
s5ChasComM3502A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 17 }
|
|
s5ChasComMDA3502A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3502A 255 }
|
|
|
|
-- Model 353X Repeater Module
|
|
s5ChasComM353X
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 18 }
|
|
s5ChasComMDA3532 -- Model 3532 Shielded Twisted Pair Repeater Module
|
|
OBJECT IDENTIFIER ::= { s5ChasComM353X 2 }
|
|
s5ChasComMDA3534 -- Model 3534 FOIRL Fiber Repeater Module
|
|
OBJECT IDENTIFIER ::= { s5ChasComM353X 4 }
|
|
|
|
-- Model 3040 Network Control Engine
|
|
s5ChasComM3040
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 19 }
|
|
s5ChasComMDA3040
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3040 255 }
|
|
|
|
-- Model 3505 Unshielded Twisted Pair Token Ring Host Module
|
|
s5ChasComM3505
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 20 }
|
|
s5ChasComMDA3505
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3505 255 }
|
|
|
|
-- Model 3505A Unshielded Twisted Pair Token Ring Host Module
|
|
s5ChasComM3505A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 21 }
|
|
s5ChasComMDA3505A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3505A 255 }
|
|
|
|
-- Model 355X FOIRL Fiber Ring-In/Ring-Out Module
|
|
s5ChasComM355X
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 22 }
|
|
s5ChasComMDA3552 -- Model 3552 STP Ring-In/Ring-Out Module
|
|
OBJECT IDENTIFIER ::= { s5ChasComM355X 2 }
|
|
s5ChasComMDA3554 -- Model 3554 FOIRL Fiber Ring-In/Ring-Out Module
|
|
OBJECT IDENTIFIER ::= { s5ChasComM355X 4 }
|
|
|
|
-- Model 3040S Network Control Engine
|
|
s5ChasComM3040S
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 23 }
|
|
s5ChasComMDA3040S
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3040S 255 }
|
|
|
|
-- Model 351X Token Ring Network Management Module
|
|
s5ChasComM351X
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 24 }
|
|
s5ChasComMDA3512 -- Model 3512 Token Ring NMM with STP RI/RO
|
|
OBJECT IDENTIFIER ::= { s5ChasComM351X 2 }
|
|
s5ChasComMDA3513 -- Model 3513 Token Ring NMM with STP Repeater
|
|
OBJECT IDENTIFIER ::= { s5ChasComM351X 3 }
|
|
s5ChasComMDA3514 -- Model 3514 Token Ring NMM with Fiber RI/RO
|
|
OBJECT IDENTIFIER ::= { s5ChasComM351X 4 }
|
|
|
|
-- Model 33XXS Ethernet High Speed Local Bridge
|
|
s5ChasComM33XXS
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 25 }
|
|
s5ChasComMDA3324S -- Model 3324S Ethernet High Speed Local Bridge with FOIRLFiber Port
|
|
OBJECT IDENTIFIER ::= { s5ChasComM33XXS 0 }
|
|
s5ChasComMDA3323S -- Model 3323S Ethernet High Speed Local Bridge with AUI
|
|
OBJECT IDENTIFIER ::= { s5ChasComM33XXS 3 }
|
|
|
|
-- Model 3386 Ethernet Remote Router
|
|
s5ChasComM338X
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 26 }
|
|
s5ChasComMDA3384 -- Model 3384 Ethernet Local Router with FOIRL Fiber Port
|
|
OBJECT IDENTIFIER ::= { s5ChasComM338X 0 }
|
|
s5ChasComMDA3383 -- Model 3383 Ethernet Local Router with AUI Port
|
|
OBJECT IDENTIFIER ::= { s5ChasComM338X 3 }
|
|
s5ChasComMDA3386 -- Model 3386 Ethernet Remote Router with Universal Port
|
|
OBJECT IDENTIFIER ::= { s5ChasComM338X 4 }
|
|
|
|
-- Model 3328 EtherSwitch Module
|
|
s5ChasComM3328
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 27 }
|
|
s5ChasComMDA3328
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3328 255 }
|
|
|
|
-- Model 3395 Ethernet terminal server
|
|
s5ChasComM3395
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 28 }
|
|
s5ChasComMDA3395
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3395 255 }
|
|
|
|
-- Model 3394 Ethernet LocalTalk Router/Repeater
|
|
s5ChasComM3394
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 29 }
|
|
s5ChasComMDA3394
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3394 255 }
|
|
|
|
-- Model 3522 Token Ring Bridge
|
|
s5ChasComM3522
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 30 }
|
|
s5ChasComMDA3522
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3522 255 }
|
|
|
|
-- Model 3395A Ethernet terminal server
|
|
s5ChasComM3395A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 31 }
|
|
s5ChasComMDA3395A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3395A 255 }
|
|
|
|
-- Model 3800 Multi Media Router Module
|
|
s5ChasComM3800
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 32 }
|
|
s5ChasComMDA3803 -- Model 3803 Ethernet Media Adapter
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3800 0 }
|
|
s5ChasComMDA3805 -- Model 3805 Token Ring Media Adapter
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3800 1 }
|
|
s5ChasComMDA3809 -- Model 3809 FDDI Media Adapter
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3800 2 }
|
|
s5ChasComMDA3806 -- Model 3806 Serial WAN Media Adapter
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3800 3 }
|
|
s5ChasComMDA3800 -- Model 3800 Multi Media Router Module
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3800 255 }
|
|
|
|
-- Model 3368 10BASE-T LattisSecure Host Module
|
|
s5ChasComM3368
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 36 }
|
|
s5ChasComMDA3368
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3368 255 }
|
|
|
|
-- Model 3307A 10BASE-T with Amp Connector Host Module
|
|
s5ChasComM3307A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 37 }
|
|
s5ChasComMDA3307A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3307A 255 }
|
|
|
|
-- Model 3308A 10BASE-T Host Module
|
|
s5ChasComM3308A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 38 }
|
|
s5ChasComMDA3308A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308A 255 }
|
|
|
|
-- Model 3301-75 Ohms Thin Net Host Module
|
|
s5ChasComM3301-75
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 41 }
|
|
s5ChasComMDA3301-75
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3301-75 255 }
|
|
|
|
-- Model 3301-93 Ohms Thin Net Host Module
|
|
s5ChasComM3301-93
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 42 }
|
|
s5ChasComMDA3301-93
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3301-93 255 }
|
|
|
|
-- Model 3502B Unshielded Twisted Pair Token Ring Host Module
|
|
s5ChasComM3502B
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 45 }
|
|
s5ChasComMDA3502B
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3502B 255 }
|
|
|
|
-- Model 3505B Unshielded Twisted Pair Token Ring Host Module
|
|
s5ChasComM3505B
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 46 }
|
|
s5ChasComMDA3505B
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3505B 255 }
|
|
|
|
-- Model 3307HD 10BASE-T 50 Pin 24 Port Host Module
|
|
s5ChasComM3307HD
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 47 }
|
|
s5ChasComMDA3307HD
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3307HD 255 }
|
|
|
|
-- Model 3356 Ethernet Remote Bridge
|
|
s5ChasComM3356
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 56 }
|
|
s5ChasSubComMDA3356X21 -- Model 3356-X.21(barrier) Enet Remote Bridge
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3356 1 }
|
|
s5ChasSubComMDA3356X21U -- Model 3356-X.21(unbarrier) Enet Remote Bridge
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3356 2 }
|
|
s5ChasSubComMDA3356RS232 -- Model 3356-RS232 Ethernet Remote Bridge
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3356 3 }
|
|
s5ChasSubComMDA3356RS449 -- Model 3356-RS449 Ethernet Remote Bridge
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3356 4 }
|
|
s5ChasSubComMDA3356V35 -- Model 3356-V.35 Ethernet Remote Bridge
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3356 5 }
|
|
s5ChasSubComMDA3356G703 -- Model 3356G703 Ethernet Remote Bridge
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3356 6 }
|
|
s5ChasSubComMDA3356T1 -- Model 3356-T1 Ethernet Remote Bridge
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3356 7 }
|
|
s5ChasSubComMDA3356 -- Model 3356 Ethernet Remote Bridge
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3356 255 }
|
|
|
|
-- Model 3902A FDDI SDDI host module
|
|
s5ChasComM3902A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 63 }
|
|
s5ChasComMDA3902A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3902A 255 }
|
|
|
|
-- Model 3910S-SD FDDI SDDI Network Management Module
|
|
s5ChasComM3910S-SD
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 67 }
|
|
s5ChasComMDA3910S-SD
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3910S-SD 255 }
|
|
|
|
-- Model 3313A Ethernet Network Management Module with AUI Port
|
|
s5ChasComM3313A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 68 }
|
|
s5ChasComMDA3313A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3313A 255 }
|
|
|
|
-- Model 3314A Ethernet Network Management Module with 10BASE-FL Port
|
|
s5ChasComM3314A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 69 }
|
|
s5ChasComMDA3314A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3314A 255 }
|
|
|
|
-- Model 3304A FOIRL Fiber Optic Host Module
|
|
s5ChasComM3304A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 70 }
|
|
s5ChasComMDA3304A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3304A 255 }
|
|
|
|
-- Model 3910SA FDDI Network Management Module
|
|
s5ChasComM3910SA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 71 }
|
|
s5ChasComMDA3910SA -- Model 3910SA FDDI NMM
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3910SA 80 }
|
|
s5ChasComMDA3910SA-SM -- Model 3910SA-SM FDDI NMM
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3910SA 160 }
|
|
|
|
-- Model 3905 UTP FDDI Host Module
|
|
s5ChasComM3905
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 73 }
|
|
s5ChasComMDA3905
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3905 0 }
|
|
|
|
-- Model 3486 LattisEngine/486
|
|
s5ChasComM3486
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 82 }
|
|
s5ChasComMDA3486
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3486 255 }
|
|
|
|
-- Model 3504-ST Token Ring Fiber Host Module
|
|
s5ChasComM3504-ST
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 83 }
|
|
s5ChasComMDA3504-ST
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3504-ST 255 }
|
|
|
|
-- Model 3517SA Token Ring Network Management Module
|
|
s5ChasComM3517SA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 101 }
|
|
s5ChasComMDA3517SA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3517SA 255 }
|
|
|
|
-- Model 3308B 10BASE-T Host Module
|
|
s5ChasComM3308B
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 102 }
|
|
s5ChasComMDA3308B
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308B 255 }
|
|
|
|
-- Model 3313SA Ethernet Network Management Module with AUI Port
|
|
s5ChasComM3313SA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 105 }
|
|
s5ChasComMDA3313SA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3313SA 255 }
|
|
|
|
-- Model 3314SA Ethernet Network Management Module with 10BASE-FL Port
|
|
s5ChasComM3314SA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 106 }
|
|
s5ChasComMDA3314SA
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3314SA 255 }
|
|
|
|
-- Model 3174 Communications Controller Module
|
|
s5ChasComM3174
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 107 }
|
|
s5ChasComMDA3174
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3174 255 }
|
|
|
|
-- Model 3522A Token Ring Bridge
|
|
s5ChasComM3522A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 108 }
|
|
s5ChasComMDA3522A
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3522A 255 }
|
|
|
|
-- Model 3299-C Terminal Multiplexor Adapter Module
|
|
s5ChasComM3299-C
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 116 }
|
|
s5ChasComMDA3299-C
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3299-C 255 }
|
|
|
|
-- Model 3299-U UTP Terminal Multiplexor Adapter Module
|
|
s5ChasComM3299-U
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 117 }
|
|
s5ChasComMDA3299-U
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3299-U 255 }
|
|
|
|
-- Model 3299-F Fiber Optic Terminal Adapter Module
|
|
s5ChasComM3299-F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 119 }
|
|
s5ChasComMDA3299-F
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3299-F 255 }
|
|
|
|
-- Model 3410 Fast Ethernet Network Management Module
|
|
s5ChasComM3410
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 120 }
|
|
s5ChasComM3410Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3410 0 }
|
|
s5ChasComM3410StoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3410Store 1 }
|
|
s5ChasComM3410StoreFlash -- FLASH Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3410Store 2 }
|
|
s5ChasComM3410StoreDram -- DRAM Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3410Store 3 }
|
|
|
|
-- Model 3405 Fast Ethernet Host Module with 12 100Base-TX Ports
|
|
s5ChasComM3405Tx12
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 121 }
|
|
s5ChasComM3405Tx12Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3405Tx12 0 }
|
|
s5ChasComM3405Tx12StoreRom -- ROM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3405Tx12Store 1 }
|
|
|
|
-- Model 3475-FX Fast Ethernet Host Module with 11 100Base-TX Ports
|
|
-- and 1 100Base-FX Port
|
|
s5ChasComM3475FxTx11
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 122 }
|
|
s5ChasComM3475FxTx11Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3475FxTx11 0 }
|
|
s5ChasComM3475FxTx11StoreRom -- ROM HostFirmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3475FxTx11Store 1 }
|
|
|
|
-- Model 3308S Desktop Switching Host Module with 22 10Base-TX Ports
|
|
-- and 2 10/100 Ethernet Ports
|
|
s5ChasComM3308S
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 130 }
|
|
s5ChasComM3308SStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308S 0 }
|
|
s5ChasComM3308SStoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308SStore 1 }
|
|
s5ChasComM3308SStoreFlash1 -- FLASH Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308SStore 2 }
|
|
s5ChasComM3308SStoreFlash2 -- FLASH Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308SStore 3 }
|
|
s5ChasComM3308SStoreFlash3 -- FLASH Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308SStore 4 }
|
|
s5ChasComM3308SStoreFlash4 -- FLASH Boot
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3308SStore 5 }
|
|
|
|
-- OpenBay Eversys S3000 Application Server Module
|
|
s5ChasComM3000ASM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 200 }
|
|
s5ChasComMDA3000ASM
|
|
OBJECT IDENTIFIER ::= { s5ChasComM3000ASM 255 }
|
|
|
|
-- Model 5110 Supervisory Module
|
|
s5ChasComSupM5110
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 258 }
|
|
s5ChasComSupM5110Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5110 0 }
|
|
s5ChasComSupM5110StoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5110Store 1 }
|
|
s5ChasComSupM5110StoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5110Store 2 }
|
|
s5ChasComSupM5110StoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5110Store 3 }
|
|
s5ChasComSupM5110StoreChaEeProm -- Chassis EEProm
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5110Store 4 }
|
|
|
|
-- Model 5304P Ethernet Host Module
|
|
s5ChasComBrdM5304P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 259 }
|
|
s5ChasComBrdM5304PStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5304P 0 }
|
|
s5ChasComBrdM5304PStore8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5304PStore 1 }
|
|
s5ChasComBrdM5304PStoreDspRom -- DSP Frimware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5304PStore 2 }
|
|
|
|
-- Model 5308 Ethernet Host Module
|
|
s5ChasComBrdM5308
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 260 }
|
|
s5ChasComBrdM5308Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5308 0 }
|
|
s5ChasComBrdM5308Store8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5308Store 1 }
|
|
s5ChasComBrdM5308StoreDspRom -- DSP Frimware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5308Store 2 }
|
|
|
|
-- Model 5308-AF Ethernet Host Module
|
|
s5ChasComBrdM5308AF
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 261 }
|
|
s5ChasComBrdM5308AFStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5308AF 0 }
|
|
s5ChasComBrdM5308AFStore8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5308AFStore 1 }
|
|
s5ChasComBrdM5308AFStoreDspRom -- DSP Frimware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5308AFStore 2 }
|
|
|
|
-- Model 5378-F Ethernet Host Module
|
|
s5ChasComBrdM5378F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 262 }
|
|
s5ChasComBrdM5378FStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5378F 0 }
|
|
s5ChasComBrdM5378FStore8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5378FStore 1 }
|
|
s5ChasComBrdM5378FStoreDspRom -- DSP Frimware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5378FStore 2 }
|
|
|
|
-- Model 5502 Token Ring Host Module
|
|
s5ChasComBrdM5502
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 263 }
|
|
s5ChasComBrdM5502Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5502 0 }
|
|
s5ChasComBrdM5502Store8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5502Store 1 }
|
|
|
|
-- Model 5505P Token Ring Host Module
|
|
s5ChasComBrdM5505P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 264 }
|
|
s5ChasComBrdM5505PStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5505P 0 }
|
|
s5ChasComBrdM5505PStore8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5505PStore 1 }
|
|
|
|
-- Model 5575-F Token Ring Host Module
|
|
s5ChasComBrdM5575F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 265 }
|
|
s5ChasComBrdM5575FStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5575F 0 }
|
|
s5ChasComBrdM5575FStore8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5575FStore 1 }
|
|
|
|
-- Model 5902 FDDI Host Module
|
|
s5ChasComBrdM5902
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 266 }
|
|
s5ChasComBrdM5902Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5902 0 }
|
|
s5ChasComBrdM5902StoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5902Store 1 }
|
|
s5ChasComBrdM5902StoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5902Store 2 }
|
|
s5ChasComBrdM5902StoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5902Store 3 }
|
|
|
|
-- Model 5904 FDDI Host Module
|
|
s5ChasComBrdM5904
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 267 }
|
|
s5ChasComBrdM5904Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5904 0 }
|
|
s5ChasComBrdM5904StoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5904Store 1 }
|
|
s5ChasComBrdM5904StoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5904Store 2 }
|
|
s5ChasComBrdM5904StoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5904Store 3 }
|
|
|
|
-- Model 5904-2SM FDDI Host Module
|
|
s5ChasComBrdM59042SM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 268 }
|
|
s5ChasComBrdM59042SMStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM59042SM 0 }
|
|
s5ChasComBrdM59042SMStoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM59042SMStore 1 }
|
|
s5ChasComBrdM59042SMStoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM59042SMStore 2 }
|
|
s5ChasComBrdM59042SMStoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM59042SMStore 3 }
|
|
|
|
-- Model 5310 Ethernet Network Management Module
|
|
s5ChasComBrdM5310
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 269 }
|
|
s5ChasComBrdM5310Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5310 0 }
|
|
s5ChasComBrdM5310StoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5310 1 }
|
|
s5ChasComBrdM5310StoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5310Store 2 }
|
|
s5ChasComBrdM5310StoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5310Store 3 }
|
|
|
|
-- Model 5510 Token Ring Network Management Module
|
|
s5ChasComBrdM5510
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 270 }
|
|
s5ChasComBrdM5510Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5510 0 }
|
|
s5ChasComBrdM5510StoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5510Store 1 }
|
|
s5ChasComBrdM5510StoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5510Store 2 }
|
|
s5ChasComBrdM5510StoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5510Store 3 }
|
|
|
|
-- Model 5910S FDDI Network Management Module
|
|
s5ChasComBrdM5910S
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 271 }
|
|
s5ChasComBrdM5910SStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5910S 0 }
|
|
s5ChasComBrdM5910SStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5910SStore 1 }
|
|
s5ChasComBrdM5910SStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5910SStore 2 }
|
|
s5ChasComBrdM5910SStoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5910SStore 3 }
|
|
|
|
-- Model 5910S-SM FDDI Network Management Module
|
|
s5ChasComBrdM5910SSM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 272 }
|
|
s5ChasComBrdM5910SSMStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5910SSM 0 }
|
|
s5ChasComBrdM5910SSMStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5910SSMStore 1 }
|
|
s5ChasComBrdM5910SSMStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5910SSMStore 2 }
|
|
s5ChasComBrdM5910SSMStoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5910SSMStore 3 }
|
|
|
|
-- Model 5311 Ethernet Data Collection Engine
|
|
s5ChasComBrdSubM5311
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 273 }
|
|
|
|
-- Model 5511 Token Ring Data Collection Engine
|
|
s5ChasComBrdSubM5511
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 274 }
|
|
|
|
-- Model 5905 FDDI Host Module
|
|
s5ChasComBrdM5905
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 275 }
|
|
s5ChasComBrdM5905Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5905 0 }
|
|
s5ChasComBrdM5905StoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5905Store 1 }
|
|
s5ChasComBrdM5905StoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5905Store 2 }
|
|
s5ChasComBrdM5905StoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5905Store 3 }
|
|
|
|
-- Model 5574-C Token Ring Cluster Repeater/Host Module
|
|
s5ChasComBrdM5575C
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 276 }
|
|
s5ChasComBrdM5575CStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5575C 0 }
|
|
s5ChasComBrdM5575CStore8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5575CStore 1 }
|
|
|
|
-- Model 559 Token Ring De-jitterizer/FPU Submodule
|
|
s5ChasComBrdM559
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 277 }
|
|
|
|
-- Model 5390 Communications Server Module
|
|
s5ChasComBrdM5390
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 278 }
|
|
s5ChasComBrdM5390Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5390 0 }
|
|
s5ChasComBrdM5390StoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5390Store 1 }
|
|
s5ChasComBrdM5390StoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5390Store 2 }
|
|
s5ChasComBrdM5390StoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5390Store 3 }
|
|
|
|
-- Model 5307 Ethernet Telco Host Module
|
|
s5ChasComBrdM5307
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 279 }
|
|
s5ChasComBrdM5307Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5307 0 }
|
|
s5ChasComBrdM5307Store8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5307Store 1 }
|
|
s5ChasComBrdM5307StoreDspRom -- DSP Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5307Store 2 }
|
|
|
|
-- Model 5308 Ethernet Host Module (Cost Reduced)
|
|
s5ChasComBrdMCR5308
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 280 }
|
|
s5ChasComBrdMCR5308Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdMCR5308 0 }
|
|
s5ChasComBrdMCR5308Store8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdMCR5308Store 1 }
|
|
s5ChasComBrdMCR5308StoreDspRom -- DSP Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdMCR5308Store 2 }
|
|
|
|
-- Model 5378-F Ethernet Cluster Host Module (Cost Reduced)
|
|
s5ChasComBrdMCR5378F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 281 }
|
|
s5ChasComBrdMCR5378FStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdMCR5378F 0 }
|
|
s5ChasComBrdMCR5378FStore8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdMCR5378FStore 1 }
|
|
s5ChasComBrdMCR5378FStoreDspRom -- DSP Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdMCR5378FStore 2 }
|
|
|
|
-- Model 5505 Token Ring STP/UTP Host Module
|
|
s5ChasComBrdM5505
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 282 }
|
|
s5ChasComBrdM5505Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5505 0 }
|
|
s5ChasComBrdM5505Store8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5505Store 1 }
|
|
|
|
-- Model 5115 Supervisory Module
|
|
s5ChasComSupM5115
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 284 }
|
|
s5ChasComSupM5115Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5115 0 }
|
|
s5ChasComSupM5115StoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5115Store 1 }
|
|
s5ChasComSupM5115StoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5115Store 2 }
|
|
s5ChasComSupM5115StoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5115Store 3 }
|
|
s5ChasComSupM5115StoreChaEeProm -- Chassis EEProm
|
|
OBJECT IDENTIFIER ::= { s5ChasComSupM5115Store 4 }
|
|
|
|
-- Model 5740 ATM Switch Control Module
|
|
s5ChasComBrdM5740
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 285 }
|
|
s5ChasComBrdM5740Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5740 0 }
|
|
s5ChasComBrdM5740Store8051Rom -- 8051 firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5740Store 1 }
|
|
s5ChasComBrdM5740StoreBoot -- EPROM boot firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5740Store 2 }
|
|
s5ChasComBrdM5740StoreDram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5740Store 3 }
|
|
s5ChasComBrdM5740StoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5740Store 4 }
|
|
s5ChasComBrdM5740StoreDisk1 -- disk drive #1
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5740Store 5 }
|
|
s5ChasComBrdM5740StoreDisk2 -- disk drive #2
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5740Store 6 }
|
|
|
|
-- Model 5720 ATM 12 Port Switch Fabric Module
|
|
s5ChasComBrdM5720
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 287 }
|
|
s5ChasComBrdM5720Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5720 0 }
|
|
s5ChasComBrdM5720Store8051Rom -- 8051 firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5720Store 1 }
|
|
s5ChasComBrdM5720StoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5720Store 2 }
|
|
s5ChasComBrdM5720StoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5720Store 3 }
|
|
|
|
-- Model 5700 ATM MDA Host Board
|
|
s5ChasComBrdM5700
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 288 }
|
|
s5ChasComBrdM5700Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5700 0 }
|
|
s5ChasComBrdM5700Store8051Rom -- 8051 firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5700Store 1 }
|
|
s5ChasComBrdM5700StoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5700Store 2 }
|
|
s5ChasComBrdM5700StoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5700Store 3 }
|
|
|
|
-- Model 5700-17 ATM 155M SONET OC-3C SMF-SC MDA
|
|
s5ChasComBrdSubM5700-17
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 289 }
|
|
|
|
-- Model 5700-24 ATM 100M TAXI MMF-MIC MDA
|
|
s5ChasComBrdSubM5700-24
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 290 }
|
|
|
|
-- Model 5700-14 ATM 155M SONET OC-3C MMF-ST MDA
|
|
s5ChasComBrdSubM5700-14
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 291 }
|
|
|
|
-- Model 5700-31 ATM 45M B3ZS 75BNC-MDA
|
|
s5ChasComBrdSubM5700-31
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 292 }
|
|
|
|
-- Model 5700-15 ATM 155M SONET OC-3C CAT5-RJ45 MDA
|
|
s5ChasComBrdSubM5700-15
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 293 }
|
|
|
|
-- Model 5715 ATM 155M SONET OC-3C 8 CAT5-RJ-45 Host Board
|
|
s5ChasComBrdM5715
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 294 }
|
|
s5ChasComBrdM5715Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5715 0 }
|
|
s5ChasComBrdM5715Store8051Rom -- 8051 firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5715Store 1 }
|
|
s5ChasComBrdM5715StoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5715Store 2 }
|
|
s5ChasComBrdM5715StoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5715Store 3 }
|
|
|
|
-- Model 5714 ATM 155M SONET OC-3C 8 MMF-ST Host Board
|
|
s5ChasComBrdM5714
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 295 }
|
|
s5ChasComBrdM5714Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5714 0 }
|
|
s5ChasComBrdM5714Store8051Rom -- 8051 firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5714Store 1 }
|
|
s5ChasComBrdM5714StoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5714Store 2 }
|
|
s5ChasComBrdM5714StoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5714Store 3 }
|
|
|
|
-- Model 5328 ATM Ethernet Switch 24 Port 10BaseT Host
|
|
s5ChasComBrdM5328
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 296 }
|
|
s5ChasComBrdM5328Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5328 0 }
|
|
s5ChasComBrdM5328Store8051Rom -- 8051 firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5328Store 1 }
|
|
s5ChasComBrdM5328StoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5328Store 2 }
|
|
s5ChasComBrdM5328StoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5328Store 3 }
|
|
|
|
-- Model 5324 ATM Ethernet Switch 10 Port 10BaseF Host
|
|
s5ChasComBrdM5324
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 297 }
|
|
s5ChasComBrdM5324Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5324 0 }
|
|
s5ChasComBrdM5324Store8051Rom -- 8051 firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5324Store 1 }
|
|
s5ChasComBrdM5324StoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5324Store 2 }
|
|
s5ChasComBrdM5324StoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5324Store 3 }
|
|
|
|
-- Model 10328-F EtherCell Concentrator
|
|
s5ChasComBrdM10328F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 298 }
|
|
s5ChasComBrdM10328FStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328F 0 }
|
|
s5ChasComBrdM10328FStoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328FStore 1 }
|
|
s5ChasComBrdM10328FStoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328FStore 2 }
|
|
s5ChasComBrdM10328FStoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328FStore 3 }
|
|
s5ChasComBrdM10328FStoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328FStore 4 }
|
|
s5ChasComBrdM10328FStoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328FStore 5 }
|
|
|
|
-- Model 10328-SM EtherCEll Concentrator
|
|
s5ChasComBrdM10328SM OBJECT IDENTIFIER ::= { s5ChasComMod 301 }
|
|
s5ChasComBrdM10328SMStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328SM 0 }
|
|
s5ChasComBrdM10328SMStoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328SMStore 1 }
|
|
s5ChasComBrdM10328SMStoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328SMStore 2 }
|
|
s5ChasComBrdM10328SMStoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328SMStore 3 }
|
|
s5ChasComBrdM10328SMStoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328SMStore 4 }
|
|
s5ChasComBrdM10328SMStoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10328SMStore 5 }
|
|
|
|
-- Model 10324-F EtherCEll Concentrator
|
|
s5ChasComBrdM10324F OBJECT IDENTIFIER ::= { s5ChasComMod 302 }
|
|
s5ChasComBrdM10324FStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10324F 0 }
|
|
s5ChasComBrdM10324FStoreSram -- SRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10324FStore 1 }
|
|
s5ChasComBrdM10324FStoreDram -- DRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10324FStore 2 }
|
|
s5ChasComBrdM10324FStoreNvram -- NVRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10324FStore 3 }
|
|
s5ChasComBrdM10324FStoreEprom -- EPROM
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10324FStore 4 }
|
|
s5ChasComBrdM10324FStoreFlash -- FLASH
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM10324FStore 5 }
|
|
|
|
-- Model 5308P Ethernet Host Module
|
|
s5ChasComBrdM5308P OBJECT IDENTIFIER ::= { s5ChasComMod 306 }
|
|
s5ChasComBrdM5308PStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5308P 0 }
|
|
s5ChasComBrdM5308PStore8051Rom -- 8051 Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5308PStore 1 }
|
|
|
|
-- Model 5310A Ethernet Network Management Mother Board Module for 5310A/5310SA
|
|
s5ChasComBrdM5310ASA OBJECT IDENTIFIER ::= { s5ChasComMod 317 }
|
|
s5ChasComBrdM5310ASAStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5310ASA 0 }
|
|
s5ChasComBrdM5310ASAStoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5310ASAStore 1 }
|
|
s5ChasComBrdM5310ASAStoreFlash -- FLASH Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5310ASAStore 2 }
|
|
s5ChasComBrdM5310ASAStoreDram -- DRAM Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5310ASAStore 3 }
|
|
|
|
-- Ethernet Management Communications Engine Submodule
|
|
s5ChasComBrdSubMMCE OBJECT IDENTIFIER ::= { s5ChasComMod 318 }
|
|
|
|
-- (Not an external product) 920-370 5740 ATM Backplane Interface
|
|
s5ChasComBrdSubM5740AtmBkplIntf
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 319 }
|
|
|
|
-- Model 5DN002 Hub 2-Slot Conectivity Motherboard
|
|
s5ChasComM5DN002m
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 342 }
|
|
s5ChasComM5DN002mStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN002m 0 }
|
|
s5ChasComM5DN002mStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN002mStore 1 }
|
|
s5ChasComM5DN002mStoreBoot -- Boot Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN002mStore 2 }
|
|
|
|
-- Model 5DN003 Hub 3-Slot Conectivity Motherboard
|
|
s5ChasComM5DN003m
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 343 }
|
|
s5ChasComM5DN003mStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN003m 0 }
|
|
s5ChasComM5DN003mStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN003mStore 1 }
|
|
s5ChasComM5DN003mStoreBoot -- Boot Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN003mStore 2 }
|
|
|
|
-- Model 5DN308P D-Day Hub 12-port RJ-45 10Base-T Module
|
|
s5ChasComM5DN308P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 344 }
|
|
|
|
-- Model 5DN304P D-Day Hub 3-port 10Base-FL Fiber Module
|
|
s5ChasComM5DN304P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 345 }
|
|
|
|
-- Model 5DN378P-F D-Day Hub 10Base-FL/10Base-T Module
|
|
s5ChasComM5DN378P-F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 346 }
|
|
|
|
-- Model 5DN307P D-Day Hub 12-port Telco 10Base-T Module
|
|
s5ChasComM5DN307P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 347 }
|
|
|
|
-- Model 5DN310 Ethernet Network Management Module
|
|
s5ChasComM5DN310
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 348 }
|
|
s5ChasComM5DN310Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN310 0 }
|
|
s5ChasComM5DN310StoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN310Store 1 }
|
|
s5ChasComM5DN310StoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN310Store 2 }
|
|
s5ChasComM5DN310StoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN310Store 3 }
|
|
|
|
-- Model N11 Data Collection Module
|
|
s5ChasComMN11
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 349 }
|
|
s5ChasComMN11Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMN11 0 }
|
|
s5ChasComMN11StoreFlash -- FLASH N11 image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMN11Store 1 }
|
|
s5ChasComMN11StoreDram -- DRAM N11 image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMN11Store 2 }
|
|
|
|
-- BayStack Ethernet Hub 12-Port RJ-45 10Base-T mother board
|
|
s5ChasComMNBayStackm1
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 350}
|
|
s5ChasComMNBayStackm1Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackm1 0 }
|
|
s5ChasComMNBayStackm1StoreRom -- ROM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackm1Store 1 }
|
|
|
|
-- BayStack Ethernet Hub 24-Port RJ-45 10Base-T mother board
|
|
s5ChasComMNBayStackm2
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 351}
|
|
s5ChasComMNBayStackm2Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackm2 0 }
|
|
s5ChasComMNBayStackm2StoreRom -- ROM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackm2Store 1 }
|
|
|
|
-- BayStack Ethernet Hub AUI Media Adapter
|
|
s5ChasComMNBayStackAui
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 352 }
|
|
|
|
-- BayStack Ethernet Hub 10Base-2 Media Adapter
|
|
s5ChasComMNBayStackThin
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 353 }
|
|
|
|
-- BayStack Ethernet Hub 10Base-FL Media Adapter
|
|
s5ChasComMNBayStackFL
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 354 }
|
|
|
|
-- BayStack Ethernet Hub Standard Ethernet Network Management Module
|
|
s5ChasComMNBayStackStdNmm
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 355 }
|
|
s5ChasComMNBayStackStdNmmStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackStdNmm 0 }
|
|
s5ChasComMNBayStackStdnmmStoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackStdNmmStore 1 }
|
|
s5ChasComMNBayStackStdNmmStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackStdNmmStore 2 }
|
|
s5ChasComMNBayStackStdNmmStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackStdNmmStore 3 }
|
|
|
|
-- BayStack Ethernet Hub Advanced Ethernet Network Management Module
|
|
s5ChasComMNBayStackAdvNmm
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 356 }
|
|
s5ChasComMNBayStackAdvNmmStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackAdvNmm 0 }
|
|
s5ChasComMNBayStackAdvNmmStoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackAdvNmmStore 1 }
|
|
s5ChasComMNBayStackAdvNmmStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackAdvNmmStore 2 }
|
|
s5ChasComMNBayStackAdvNmmStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackAdvNmmStore 3 }
|
|
|
|
-- Model BayStack Ethernet Hub 10Base-T Media Adapter
|
|
s5ChasComMF-10BaseT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 357 }
|
|
|
|
-- Model 58000 1/100 Ethernet Switch Management Module
|
|
s5ChasComBrdM58000
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 359 }
|
|
s5ChasComBrdM58000Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM58000 0 }
|
|
s5ChasComBrdM58000StoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM58000Store 1 }
|
|
s5ChasComBrdM58000StoreFlash -- FLASH Switch Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM58000Store 2 }
|
|
|
|
-- Model 58000-14 2 Port 100BASE-F MDA with SC connectors
|
|
s5ChasComBrdSubM5800014
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 360 }
|
|
|
|
-- Model 58000-15 2 Port 100BASE-T MDA with RJ45 connectors
|
|
s5ChasComBrdSubM5800015
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 361 }
|
|
|
|
-- Model 58000-16 2 Port 100BASE-T/100BASE-F MDA with one RJ45 and SC connector
|
|
s5ChasComBrdSubM5800016
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 362 }
|
|
|
|
-- Model 58000 MDA expansion module for model 58000 Ethernet Switch
|
|
s5ChasComBrdSubM58000MdaExp
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 363 }
|
|
|
|
-- Model 5DN378P-A D-Day Hub 10Base-AUI/10Base-T Module
|
|
s5ChasComM5DN378P-A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 364 }
|
|
|
|
-- Mother Board for BayStack 12 Port 100BAST-T Hub
|
|
s5ChasComMBayStack100m1
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 365 }
|
|
s5ChasComMBayStack100m1Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100m1 0 }
|
|
s5ChasComMBayStack100m1StoreRom -- ROM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100m1Store 1 }
|
|
|
|
-- Advanced NMM for BayStack 100BAST-T Hub
|
|
s5ChasComMBayStack100Nmm
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 366 }
|
|
s5ChasComMBayStack100NmmStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100Nmm 0 }
|
|
s5ChasComMBayStack100NmmStoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100NmmStore 1 }
|
|
s5ChasComMBayStack100NmmStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100NmmStore 2 }
|
|
s5ChasComMBayStack100NmmStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack100NmmStore 3 }
|
|
|
|
-- 100BASE-FX MDA with SC connector for BayStack 100BASE-T Hub
|
|
s5ChasComMBayStack100-FxMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 368 }
|
|
|
|
-- 100BASE-TX MDA with RJ/45 connector for BayStack 100BASE-T Hub
|
|
s5ChasComMBayStack100-TxMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 369 }
|
|
|
|
-- 12 port 100BASE-TX expansion module for BayStack 100BASE-T Hub
|
|
s5ChasComMBayStack100-Tx12
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 371 }
|
|
|
|
-- D5000 Model 5DN301P 4 port ThinNet module with BNC coax connectors
|
|
s5ChasComM5DN301P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 372 }
|
|
|
|
--5000 Model 5307PS-HD Ethernet Host Module (36 Ports with Telco & BaySecure)
|
|
s5ChasComBrdM5307PS-HD
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 373}
|
|
s5ChasComBrdM5307PS-HDStore
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5307PS-HD 0}
|
|
s5ChasComBrdM5307PS-HDStore8051Rom
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5307PS-HDStore 1}
|
|
|
|
--5000 Model 5300P Ethernet Host Module with 4 MDA sockets
|
|
s5ChasComBrdM5300P
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 374}
|
|
s5ChasComBrdM5300PStore
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5300P 0}
|
|
s5ChasComBrdM5300PStore8051Rom
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5300PStore 1}
|
|
|
|
-- BH/Catapult Modules
|
|
s5ChasComMod-5328mEther16PC10BT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 375 }
|
|
s5ChasComMod-5724mATM4PMMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 376 }
|
|
s5ChasComMod-5724MmATMMCP4PMMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 377 }
|
|
|
|
s5ChasComMod-5328MmEtherMCP8PC10BT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 378 }
|
|
s5ChasComMod-5328FXmEther12P2FXP
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 379 }
|
|
-- 5000BH Model 5324 12 port 10Base-FL Ethernet Switching Host
|
|
s5ChasComMod-5324mEther12PFL
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 380 }
|
|
|
|
s5ChasComMod-5525mTR8PCopper
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 381 }
|
|
s5ChasComMod-5525MmTRMCP4PCopper
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 382 }
|
|
s5ChasComMod-5524mTR8PFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 383 }
|
|
s5ChasComMod-5524MmTR4PFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 384 }
|
|
s5ChasComMod-5924mFDDI1P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 385 }
|
|
s5ChasComMod-5824mEther4PFX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 386 }
|
|
s5ChasComMod-5828FmEther2PTX2PFX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 387 }
|
|
s5ChasComMod-5824MmEtherMCP2PFX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 388 }
|
|
s5ChasComMod-5724SMmATM4PSMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 389 }
|
|
s5ChasComMod-5725mATM4PCopper
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 390 }
|
|
s5ChasComMod-5721DS3mATM2P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 391 }
|
|
s5ChasComMod-5721E3mATM2P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 392 }
|
|
-- 5380 Ethernet Router Base Module with connections for 4 Enet backplanes and 2 Net Modules
|
|
s5ChasComMod-5380E4Bkp2N
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 395 }
|
|
-- 5580 Token Ring Router Base Module with connections for 4 TR backplanes and 2 Net Modules
|
|
s5ChasComMod-5380TR4Bkp2N
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 396 }
|
|
|
|
-- 5000 Router Dual Ethernet Net Module with 2 AUI/10BASE-T ports
|
|
s5ChasComMod-5000ENetD10-T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 397 }
|
|
-- 5000 Router 100BASE-T Net Module with Single MII/100BASE-TX port
|
|
s5ChasComMod-5000ENetS100-T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 398 }
|
|
-- 5000 Router Dual Token Ring Net Module with 2 Token Ring DB-9 ports
|
|
s5ChasComMod-5000TRNetD-DB9
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 399 }
|
|
-- 5000 Router Multi Mode FDDI Net Module with one DAS port with MIC connectors
|
|
s5ChasComMod-5000MMFibNetD-DASMIC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 400 }
|
|
-- 5000 Router Single Mode FDDI Net Module with one DAS port with MIC connectors
|
|
s5ChasComMod-5000SMFibNetS-DASMIC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 401 }
|
|
-- 5000 Router Single/Multi Mode FDDI Net Module with one DAS port with MIC connectors
|
|
s5ChasComMod-5000SMMMFibNetS-DASMIC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 402 }
|
|
-- 5000 Router Multi/Single Mode FDDI Net Module with one DAS port with MIC connectors
|
|
s5ChasComMod-5000MMSMFibNetS-DASMIC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 403 }
|
|
-- 5000 Router Dual Sync Net Module with 2 Sync WAN ports through two 44-pin connectors
|
|
s5ChasComMod-5000SynNetD-WAN44
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 404 }
|
|
-- 5000 Router Quad BRI Net Module with four 8 pin modular ISDN BRI ports
|
|
s5ChasComMod-5000SynNetQ-ISDNBRI8
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 405 }
|
|
-- 5000 Router MCE1 Net Module with one Multi-Channel 75/120 Ohm E1 port
|
|
s5ChasComMod-5000MCE1NetQ-75120
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 406 }
|
|
-- 5000 Router MCT1 Net Module with one Multi-Channel RJ-48C T1 port
|
|
s5ChasComMod-5000MCT1NetQ-RJ48C
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 407 }
|
|
-- 5000 Router Quad Sync Net Module with four 50 pin connectors
|
|
s5ChasComMod-5000SynNet4-50Pin
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 408 }
|
|
-- 5000 Router Compression Co-Processor Module, occupying 1 net module location
|
|
s5ChasComMod-5000Co-Processor
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 409 }
|
|
-- 5000 Router Multi Mode 155M OC3 ATM Net Module with one SC port
|
|
s5ChasComMod-5000ATMNet1-MMOC3
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 410 }
|
|
-- 5000 Router Single Mode 155M OC3 ATM Net Module with one SC port
|
|
s5ChasComMod-5000ATMNet1-SMOC3
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 411 }
|
|
-- 5000 Router DS3 ATM Net Module with one DS3 ATM port
|
|
s5ChasComMod-5000ATMNet1-DS3
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 412 }
|
|
-- 5000 Router E3 ATM Net Module with one E3 ATM port
|
|
s5ChasComMod-5000ATMNet1-E3
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 413 }
|
|
-- Model 58000-109 2 port FDDI MDA with MIC Connectors
|
|
s5ChasComBrdSubM58000Fddi
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 414 }
|
|
|
|
-- Model 28200 10/100 Ethernet Switch Mother board and Backplane
|
|
s5ChasComBrdM28200
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 415 }
|
|
s5ChasComBrdM28200Store -- Storage Areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM28200 0 }
|
|
s5ChasComBrdM28200StoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM28200Store 1 }
|
|
s5ChasComBrdM28200StoreFlash -- Flash Switch Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM28200Store 2 }
|
|
s5ChasComBrdM28200StoreDram -- DRAM Switch Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM28200Store 3 }
|
|
|
|
-- Model 28200-15 8 port 10 Base-T MDA with RJ45 Connectors
|
|
s5ChasComBrdSubM2820015
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 416 }
|
|
|
|
-- Model 28200-14 4 port 10 Base-FL MDA with ST Connectors
|
|
s5ChasComBrdSubM2820014
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 417 }
|
|
|
|
-- Model 28200-105 2 port 100 Base-TX MDA with RJ45 Connectors
|
|
s5ChasComBrdSubM28200105
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 418 }
|
|
|
|
-- Model 28200-104 2 port 100 Base-FX MDA with SC Connectors
|
|
s5ChasComBrdSubM28200104
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 419 }
|
|
|
|
-- Model 28200-106 2 port MDA with one100 Base-TX RJ45 port
|
|
-- and one 100Base-FX SC port
|
|
s5ChasComBrdSubM28200106
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 420 }
|
|
|
|
-- Model 28200-EXP 2 port expansion MDA for Bay Networks
|
|
-- proprietary trunk connection.
|
|
s5ChasComBrdSubM28200Exp
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 421 }
|
|
|
|
-- Model 28200-724 Single port ATM 155Mb MMF OC3 MDA with MIC connectors
|
|
s5ChasComBrdSubM28200Atm
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 422 }
|
|
|
|
-- Model 28200-109 2 port FDDI MDA
|
|
-- with MIC Connectors
|
|
s5ChasComBrdSubM28200Fddi
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 423 }
|
|
|
|
-- Model 28200-N11 10Mb Data Collection Module
|
|
s5ChasComBrdSubM28200N11
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 424 }
|
|
|
|
-- Model 28200-N111 10/100Mb Data Collection Module
|
|
s5ChasComBrdSubM28200N111
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 425 }
|
|
|
|
-- Centillion Component Modules
|
|
s5ChasComMod-c100mTR4PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 426 }
|
|
s5ChasComMod-c100mTRMCP4PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 427 }
|
|
s5ChasComMod-c100mATM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 428 }
|
|
s5ChasComMod-c100mTRFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 429 }
|
|
s5ChasComMod-c100mTRMCPFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 430 }
|
|
s5ChasComMod-c100mEther16PC10BT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 431 }
|
|
s5ChasComMod-c100mEtherMCP8PC10BT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 432 }
|
|
s5ChasComMod-c100mATM2PSMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 433 }
|
|
s5ChasComMod-c100mATM2PCopper
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 434 }
|
|
s5ChasComMod-c100mATM4PMMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 435 }
|
|
s5ChasComMod-c100mATM4PSMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 436 }
|
|
s5ChasComMod-c100mATM4PCopper
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 437 }
|
|
s5ChasComMod-c100mATMMCP2PSMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 438 }
|
|
s5ChasComMod-c100mATMMCP2PMMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 439 }
|
|
s5ChasComMod-c100mATMMCP2PCopper
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 440 }
|
|
s5ChasComMod-c100mATMMCP4PSMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 441 }
|
|
s5ChasComMod-c100mATMMCP4PMMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 442 }
|
|
s5ChasComMod-c100mATMMCP4PCopper
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 443 }
|
|
s5ChasComMod-c100mATM2PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 444 }
|
|
s5ChasComMod-c100mATM4PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 445 }
|
|
s5ChasComMod-c100mATMMCP2PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 446 }
|
|
s5ChasComMod-c100mATMMCP4PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 447 }
|
|
|
|
--5300P Model Dummy OID No Media Adapter Fitted
|
|
s5ChasComBrdSubDummy
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 448 }
|
|
--5300P Model 5300-T 10BASE-T Media Adapter
|
|
s5ChasComBrdSub5300-T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 449 }
|
|
--5300P Model 5300-A AUI Media Adapter (Female)
|
|
s5ChasComBrdSub5300-A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 450 }
|
|
--5300P Model 5300-D Male AUI Media Adapter
|
|
s5ChasComBrdSub5300-D
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 451 }
|
|
--5300P Model 5300-F 10BASE-F Media Adapter
|
|
s5ChasComBrdSub5300-F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 452 }
|
|
--5300P Model 5300-S Single Mode Fiber Media Adapter
|
|
s5ChasComBrdSub5300-S
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 453 }
|
|
--5300P Model 5300-2 10BASE-2 Thinnet Media Adapter
|
|
s5ChasComBrdSub5300-2
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 454 }
|
|
|
|
-- BayStack Token Ring Hub 24 port Motherboard
|
|
s5ChasComMBayStackTrm1
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 456 }
|
|
s5ChasComMBayStackTrm1Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrm1 0 }
|
|
s5ChasComMBayStackTrm1StoreFlash -- FLASH Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrm1Store 1 }
|
|
s5ChasComMBayStackTrm1StoreBoot -- BOOT Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrm1Store 2 }
|
|
|
|
-- BayStack Token Ring Network Management Module
|
|
s5ChasComMBayStackTrNmm
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 457 }
|
|
s5ChasComMBayStackTrNmmStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrNmm 0 }
|
|
s5ChasComMBayStackTrNmmStoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrNmmStore 1 }
|
|
s5ChasComMBayStackTrNmmStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrNmmStore 2 }
|
|
s5ChasComMBayStackTrNmmStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStackTrNmmStore 3 }
|
|
|
|
-- BayStack Token Ring Hub Fiber MDA module
|
|
s5ChasComMBayStackTrMDAFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 458 }
|
|
|
|
-- BayStack Token Ring Hub Copper MDA module
|
|
s5ChasComMBayStackTrMDACopper
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 459 }
|
|
|
|
-- BayStack Token Ring Hub DCM module
|
|
s5ChasComMBayStackTrDCM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 460 }
|
|
|
|
-- BayStack Token Ring Hub Multi-Ring module
|
|
s5ChasComMBayStackTrMRM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 461 }
|
|
|
|
-- BayStack Ethernet Hub 24-port Telco 10Base-T motherboard
|
|
s5ChasComMNBayStackm3
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 462 }
|
|
s5ChasComMNBayStackm3Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackm3 0 }
|
|
s5ChasComMNBayStackm3StoreRom -- ROM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackm3Store 1 }
|
|
|
|
-- BayStack Ethernet Hub 8 port 10Base-2 motherboard
|
|
s5ChasComMNBayStackm4
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 463 }
|
|
s5ChasComMNBayStackm4Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackm4 0 }
|
|
s5ChasComMNBayStackm4StoreRom -- ROM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComMNBayStackm4Store 1 }
|
|
|
|
-- BayStack Ethernet Hub Redundant Link Capable 10Base-FL Media Adapter
|
|
s5ChasComMNBayStackRedFL
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 464 }
|
|
|
|
-- BayStack Ethernet Hub Single Mode Fiber Media Adapter
|
|
s5ChasComMNBayStackSMFL
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 465 }
|
|
|
|
-- BayStack Ethernet Hub Redundant-Link Capable Single Mode Fiber Media Adapter
|
|
s5ChasComMNBayStackSMRedFL
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 466 }
|
|
|
|
--5000 Model 5308S Ethernet Host Module with BaySecure
|
|
s5ChasComBrdM5308S
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 467}
|
|
s5ChasComBrdM5308SStore
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5308S 0}
|
|
s5ChasComBrdM5308SStore8051Rom
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5308SStore 1}
|
|
|
|
--5000 Model 5307S Ethernet Host Module with BaySecure
|
|
s5ChasComBrdM5307S
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 468}
|
|
s5ChasComBrdM5307SStore
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5307S 0}
|
|
s5ChasComBrdM5307SStore8051Rom
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5307SStore 1}
|
|
|
|
--5000 Model 5308PS Ethernet Host Module with BaySecure
|
|
s5ChasComBrdM5308PS
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 469}
|
|
s5ChasComBrdM5308PSStore
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5308PS 0}
|
|
s5ChasComBrdM5308PSStore8051Rom
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5308PSStore 1}
|
|
|
|
--5000 Model 5307PS Ethernet Host Module with BaySecure
|
|
s5ChasComBrdM5307PS
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 470}
|
|
s5ChasComBrdM5307PSStore
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5307PS 0}
|
|
s5ChasComBrdM5307PSStore8051Rom
|
|
OBJECT IDENTIFIER ::= {s5ChasComBrdM5307PSStore 1}
|
|
|
|
-- Model 5DN308PS D5000 Ethernet Host MDA with BaySecure
|
|
s5ChasComM5DN308PS
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 471 }
|
|
|
|
-- Model 5DN307PS D5000 Ethernet Host MDA with BaySecure
|
|
s5ChasComM5DN307PS
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 472 }
|
|
|
|
-- Model 5DN378P-SM D5000 Ethernet Host MDA with BaySecure
|
|
s5ChasComM5DN378P-SM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 473 }
|
|
|
|
-- BayStack Ethernet Hub 6 port 10BaseFL motherboard
|
|
s5ChasComMNBayStackm5
|
|
OBJECT IDENTIFIER ::= {s5ChasComMod 477}
|
|
s5ChasComMNBayStackm5Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= {s5ChasComMNBayStackm5 0 }
|
|
s5ChasComMNBayStackm5StoreRom -- ROM Host Firmware
|
|
OBJECT IDENTIFIER ::= {s5ChasComMNBayStackm5Store 1 }
|
|
|
|
-- BayStack 301 Ethernet Switch
|
|
s5ChasComMBayStack301
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 478 }
|
|
s5ChasComMBayStack301Store
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack301 0 }
|
|
s5ChasComMBayStack301MaxRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack301Store 1 }
|
|
s5ChasComMBayStack301InstalledRAM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack301Store 2 }
|
|
s5ChasComMBayStack301Flash
|
|
OBJECT IDENTIFIER ::= { s5ChasComMBayStack301Store 3 }
|
|
|
|
-- Model 5DN003A Hub 3-Slot Connectivity Motherboard
|
|
-- with Temperature Sensor
|
|
s5ChasComM5DN003Am
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 485 }
|
|
s5ChasComM5DN003AmStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN003Am 0 }
|
|
s5ChasComM5DN003AmStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN003AmStore 1 }
|
|
s5ChasComM5DN003AmStoreBoot -- Boot Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN003AmStore 2 }
|
|
|
|
-- Model 5DN002A Hub 2-Slot Connectivity Motherboard
|
|
-- with Temperature Sensor
|
|
s5ChasComM5DN002Am
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 486 }
|
|
s5ChasComM5DN002AmStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN002Am 0 }
|
|
s5ChasComM5DN002AmStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN002AmStore 1 }
|
|
s5ChasComM5DN002AmStoreBoot -- Boot Agent Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5DN002AmStore 2 }
|
|
|
|
-- 5000 Model 5405 Fast Ethernet Host Module
|
|
s5ChasComBrdM5405
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 500 }
|
|
s5ChasComBrdM5405Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5405 0 }
|
|
s5ChasComBrdM5405StoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5405Store 1 }
|
|
s5ChasComBrdM5405StoreFlash -- FLASH Host Firmware Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5405Store 2 }
|
|
s5ChasComBrdM5405StoreDram -- DRAM Host Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5405Store 3 }
|
|
|
|
-- 5000 Model 5475-FX Fast Ethernet Host Module
|
|
s5ChasComBrdM5475FX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 501 }
|
|
s5ChasComBrdM5475FXStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5475FX 0 }
|
|
s5ChasComBrdM5475FXStoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5475FXStore 1 }
|
|
s5ChasComBrdM5475FXStoreFlash -- FLASH Host Firmware Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5475FXStore 2 }
|
|
s5ChasComBrdM5475FXStoreDram -- DRAM Host Image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5475FXStore 3 }
|
|
|
|
s5ChasComMod-c100mEther12P2FXP
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 507}
|
|
s5ChasComMod-c100mEther14P2TXP
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 508}
|
|
|
|
--Model 5605P Fast Ethernet Host Module
|
|
s5ChasComBrdM5605P
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 510 }
|
|
s5ChasComBrdM5605PStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5605P 0 }
|
|
s5ChasComBrdM5605PStoreBoot -- Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5605PStore 1 }
|
|
s5ChasComBrdM5605PStoreFlash -- Flash Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5605PStore 2 }
|
|
s5ChasComBrdM5605PStoreDram -- DRAM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5605PStore 3 }
|
|
|
|
-- Model 5675P-FX Fast Ethernet Host Module
|
|
s5ChasComBrdM5675PFX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 511 }
|
|
s5ChasComBrdM5675PFXStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5675PFX 0 }
|
|
s5ChasComBrdM5675PFXStoreBoot -- Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5675PFXStore 1 }
|
|
s5ChasComBrdM5675PFXStoreFlash -- Flash Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5675PFXStore 2 }
|
|
s5ChasComBrdM5675PFXStoreDram -- DRAM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5675PFXStore 3 }
|
|
|
|
-- Model 5616 Fast Ethernet Network Management Module
|
|
s5ChasComBrdM5616
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 512 }
|
|
s5ChasComBrdM5616Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5616 0 }
|
|
s5ChasComBrdM5616StoreBoot -- FLASH Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5616 1 }
|
|
s5ChasComBrdM5616StoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5616Store 2 }
|
|
s5ChasComBrdM5616StoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5616Store 3 }
|
|
|
|
-- Model 5316 Ethernet Network Management Module
|
|
s5ChasComBrdM5316
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 513 }
|
|
s5ChasComBrdM5316Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5316 0 }
|
|
s5ChasComBrdM5316StoreBoot -- FLASH Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5316 1 }
|
|
s5ChasComBrdM5316StoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5316Store 2 }
|
|
s5ChasComBrdM5316StoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5316Store 3 }
|
|
|
|
-- 100Base-FX MDA for 3308S Desktop Switching Host
|
|
s5ChasComM3308S-FxMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 514 }
|
|
|
|
-- BayStack302T Board (or slots) group
|
|
s5ChasComBrdBayStack302T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 515 }
|
|
s5ChasComBrdBayStack302TStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack302T 0 }
|
|
s5ChasComBrdBayStack302TFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack302TStore 1 }
|
|
s5ChasComBrdBayStack302TDram -- DRAM image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack302TStore 2 }
|
|
|
|
-- BayStack302F Board (or slots) group
|
|
s5ChasComBrdBayStack302F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 516 }
|
|
s5ChasComBrdBayStack302FStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack302F 0 }
|
|
s5ChasComBrdBayStack302FFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack302FStore 1 }
|
|
s5ChasComBrdBayStack302FDram -- DRAM image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack302FStore 2 }
|
|
|
|
--C100 8Port 10 Base FL switching Module
|
|
s5ChasComMod-c100mEther8P10FL
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 517}
|
|
|
|
--C100 14 port 12x10BT/2x100BT Fiber
|
|
s5ChasComMod-c100mEther12P2BTP
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 518}
|
|
|
|
--C100 4 port 100BT Enet slave card
|
|
s5ChasComMod-c100mEther4P100BT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 519}
|
|
|
|
-- 5000BH Model 5425 4 port 100 Base TX Ethernet Switching Host Module
|
|
s5ChasComMod-5425mEther4PC100BT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 520 }
|
|
|
|
--C100 8/2 ethernet combo card (8 port 10BT, 2 port 100TX)
|
|
s5ChasComMod-c100mEther8P2TXP
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 527 }
|
|
|
|
-- BayStack350 Switch Board (or slots) group
|
|
s5ChasComBrdBayStack350T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 528 }
|
|
s5ChasComBrdBayStack350TStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350T 0 }
|
|
s5ChasComBrdBayStack350TFlash -- Flash image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350TStore 1 }
|
|
s5ChasComBrdBayStack350TBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350TStore 2 }
|
|
s5ChasComBrdBayStack350TDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350TStore 3 }
|
|
|
|
s5ChasComBrdBayStack350F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 529 }
|
|
s5ChasComBrdBayStack350FStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350F 0 }
|
|
s5ChasComBrdBayStack350FFlash -- Flash image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350FStore 1 }
|
|
s5ChasComBrdBayStack350FBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350FStore 2 }
|
|
s5ChasComBrdBayStack350FDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350FStore 3 }
|
|
|
|
s5ChasComBrdBayStack350FHD
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 530 }
|
|
s5ChasComBrdBayStack350FHDStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350FHD 0 }
|
|
s5ChasComBrdBayStack350FHDFlash -- Flash image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350FHDStore 1 }
|
|
s5ChasComBrdBayStack350FHDBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350FHDStore 2 }
|
|
s5ChasComBrdBayStack350FHDDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350FHDStore 3 }
|
|
|
|
s5ChasComBrdBayStack350THD
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 531 }
|
|
s5ChasComBrdBayStack350THDStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350THD 0 }
|
|
s5ChasComBrdBayStack350THDFlash -- Flash image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350THDStore 1 }
|
|
s5ChasComBrdBayStack350THDBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350THDStore 2 }
|
|
s5ChasComBrdBayStack350THDDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350THDStore 3 }
|
|
|
|
-- 5000BH module 5724M/SM 4 port SMF ATM MCP
|
|
s5ChasComMod-5724M-SMmATMMCP4PSMFiber
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 533 }
|
|
|
|
-- Switch Node Component Modules
|
|
-- Switch Node 16 Port 10BASET Switch Net Module
|
|
s5ChasComMod-SwNode10t16
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 534 }
|
|
|
|
-- Switch Node 2 port 100BASET Switch Net Module
|
|
s5ChasComMod-SwNode100tx2
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 535 }
|
|
|
|
-- Switch Node 8 port 10 Meg Fiber Switch Net Module
|
|
s5ChasComMod-SwNode10f8
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 536 }
|
|
|
|
-- Switch Node 16 port 100BASET Switch Net Module
|
|
s5ChasComMod-SwNode100tx16
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 537 }
|
|
|
|
-- Switch Node 3 port 100 Meg Fiber Switch Net Module
|
|
s5ChasComMod-SwNode100fx3
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 541 }
|
|
|
|
-- Switch Node DCM module
|
|
s5ChasComDCMX220SwNode
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 542 }
|
|
|
|
-- C100 16 port 4x4 100 Base TX Ethernet Bank Switching Host Module
|
|
s5ChasComMod-c100mEther4x4P100BT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 544 }
|
|
|
|
-- C100 4 port 100FX Ethernet Switching Host Module
|
|
s5ChasComMod-c100mEther4P100FX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 545 }
|
|
|
|
s5ChasComBrdBayStack150 -- BayStack150 24 port Master Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 546 }
|
|
|
|
s5ChasComBrdBayStack152 -- BayStack150 12 port Master Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 547 }
|
|
|
|
s5ChasComBrdBayStack151 -- BayStack150 24 port Slave Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 548 }
|
|
|
|
s5ChasComBrdBayStack153 -- BayStack150 12 port Slave Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 549 }
|
|
|
|
s5ChasComBrdBayStack150NMM -- BayStack150 NMM in the Master unit
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 550 }
|
|
s5ChasComBrdBayStack150NMMStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack150NMM 0 }
|
|
s5ChasComBrdBayStack150NMMStoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack150NMMStore 1 }
|
|
s5ChasComBrdBayStack150NMMStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack150NMMStore 2 }
|
|
s5ChasComBrdBayStack150NMMStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack150NMMStore 3 }
|
|
|
|
-- BayStack150 Expansion Module on NMM
|
|
s5ChasComBrdBayStack150NMMExpMod
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 551 }
|
|
|
|
-- C100 ATMSpeed MDA Switch Host Module
|
|
s5ChasComMod-C100ATMMDAhost
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 552 }
|
|
-- C100 ATMSpeed MDA MCP Module
|
|
s5ChasComMod-C100ATMMDAMcp
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 553 }
|
|
-- 5720 ATM MDA switch host module
|
|
s5ChasComMod-5720ATMMDAhost
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 554 }
|
|
-- 5720M ATM MDA MCP module
|
|
s5ChasComMod-5720MATMMDAMcp
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 555 }
|
|
-- 5720-14 Multimode fiber MDA
|
|
s5ChasComMod-5720-14MultiModeMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 556 }
|
|
-- 5720-15 Unshielded twisted pair MDA
|
|
s5ChasComMod-5720-15UTPMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 557 }
|
|
-- 5720-17 Singlemode Fiber MDA
|
|
s5ChasComMod-5720-17SingleModeMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 558 }
|
|
-- 5720-31 DS3 MDA 980-714-B
|
|
s5ChasComMod-5720-31DS3Mda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 559 }
|
|
-- 5720-41 E3 MDA 980-797-A
|
|
s5ChasComMod-5720-41E3Mda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 560 }
|
|
|
|
-- Switch Node CPU Module
|
|
s5ChasComMod-SwNodeCPU
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 561 }
|
|
|
|
-- 8 Port UTP TokenSpeed MCP for the C100
|
|
s5ChasComMod-c1008PUTPTRMcp
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 562 }
|
|
-- 8 Port UTP TokenSpeed Switch Host Module for the C100
|
|
s5ChasComMod-c1008PUTPTR
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 563 }
|
|
|
|
-- Model 5328-HD Ethernet 24 Port 10Base-T Switch Host Module
|
|
s5ChasComBrdM5328-HD
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 564 }
|
|
s5ChasComBrdM5328-HDStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5328-HD 0 }
|
|
s5ChasComBrdM5328-HDStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5328-HDStore 1 }
|
|
s5ChasComBrdM5328-HDStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5328-HDStore 2 }
|
|
|
|
-- 5000BH Model 5625 24 port 10/100 Ethernet Copper Switch Host
|
|
s5ChasComBrdM5625
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 565 }
|
|
|
|
-- Model 5455 Ethernet 16 port 4 * 4 100BASE-TX Bank Switch Net Module
|
|
s5ChasComBrdM5455
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 568 }
|
|
s5ChasComBrdM5455Store -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5455 0 }
|
|
s5ChasComBrdM5455StoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5455Store 1 }
|
|
s5ChasComBrdM5455StoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5455Store 2 }
|
|
|
|
-- Model 5611-DCM Data Collection Module for 5616SA
|
|
s5ChasComM5611-DCM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 569 }
|
|
s5ChasComM5611-DCMStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5611-DCM 0 }
|
|
s5ChasComM5611-DCMStoreFlash -- FLASH image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5611-DCMStore 1 }
|
|
s5ChasComM5611-DCMStoreDram -- DRAM image
|
|
OBJECT IDENTIFIER ::= { s5ChasComM5611-DCMStore 2 }
|
|
|
|
s5ChasComBrdBayStack202 -- BayStack200 12Tx port Host Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 570 }
|
|
|
|
s5ChasComBrdBayStack203 -- BayStack200 12Tx 1Fx port Host Unit Repeater Brd
|
|
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 571 }
|
|
|
|
s5ChasComBrdBayStack204 -- BayStack200 24 port Host Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 572 }
|
|
|
|
s5ChasComBrdBayStack205 -- BayStack200 12 port Host Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 573 }
|
|
|
|
s5ChasComBrdBayStack200NMM -- BayStack200 NMM in the NMM Host Unit
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 574 }
|
|
s5ChasComBrdBayStack200NMMStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack200NMM 0 }
|
|
s5ChasComBrdBayStack200NMMStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack200NMMStore 1 }
|
|
s5ChasComBrdBayStack200NMMStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack200NMMStore 2 }
|
|
|
|
-- BayStack 303 24+1 10BASE-T/100BASE-T Switch with 1 MDA
|
|
s5ChasComMBayStack303
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 575 }
|
|
|
|
-- BayStack 304 12+1 10BASE-T/100BASE-T Switch with 1 MDA
|
|
s5ChasComMBayStack304
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 576 }
|
|
|
|
-- BayStack 303A 24+1 10BASE-T/100BASE-T Switch with 1 MDA
|
|
s5ChasComMBayStack303A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 577 }
|
|
|
|
-- BayStack 304A 12+1 10BASE-T/100BASE-T Switch with 1 MDA
|
|
s5ChasComMBayStack304A
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 578 }
|
|
|
|
-- Model MFX-1 100BASE-FX MDA for BayStack 303 and 304
|
|
s5ChasComMBayStack303-304FxMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 579 }
|
|
|
|
-- Model MTX-1 10/100 MDA for BayStack 303 and 304
|
|
s5ChasComMBayStack303-304TxMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 580 }
|
|
|
|
-- Model 5665 10/100 Ethernet Switch Host Module
|
|
s5ChasComBrdM5665
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 581 }
|
|
s5ChasComBrdM5665Store -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5665 0 }
|
|
s5ChasComBrdM5665StoreFlash -- Flash Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5665Store 1 }
|
|
s5ChasComBrdM5665StoreDram -- DRAM Host Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5665Store 2 }
|
|
|
|
-- Model 5660-FX 100Base-FX Up-link Segment Switch NMM Module
|
|
-- with "S", "C", and "N" bus connections.
|
|
s5ChasComBrdM5660FX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 583 }
|
|
s5ChasComBrdM5660FXStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5660FX 0 }
|
|
s5ChasComBrdM5660FXStoreFlash -- Flash Agent Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5660FXStore 1 }
|
|
s5ChasComBrdM5660FXStoreDram -- DRAM Agent Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5660FXStore 2 }
|
|
|
|
-- Model 5620-FX 10/100Base-FX Up-link Segment Switch NMM Module
|
|
-- with "C" and "N" bus connections.
|
|
s5ChasComBrdM5620FX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 584 }
|
|
s5ChasComBrdM5620FXStore -- Storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5620FX 0 }
|
|
s5ChasComBrdM5620FXStoreFlash -- Flash Agent Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5620FXStore 1 }
|
|
s5ChasComBrdM5620FXStoreDram -- DRAM Agent Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdM5620FXStore 2 }
|
|
|
|
s5ChasComBrdBayStack250 -- BayStack250 12 port NMM Host Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 595 }
|
|
|
|
s5ChasComBrdBayStack251 -- BayStack250 12 port Host Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 596 }
|
|
|
|
s5ChasComBrdBayStack252 -- BayStack250 24 port Host Unit Repeater Brd
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 597 }
|
|
|
|
s5ChasComBrdBayStack250NMM -- BayStack250 NMM in the NMM Host Unit
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 598 }
|
|
s5ChasComBrdBayStack250NMMStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack250NMM 0 }
|
|
s5ChasComBrdBayStack250NMMStoreFlash -- FLASH Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack250NMMStore 1 }
|
|
s5ChasComBrdBayStack250NMMStoreDram -- DRAM Agent image
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack250NMMStore 2 }
|
|
s5ChasComBrdBayStack250NMMStoreBoot -- EPROM Boot Firmware
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack250NMMStore 3 }
|
|
|
|
--C100 24 Port 10BASE-T Switch Host Module with 2 Telco Connectors
|
|
s5ChasComMod-c100mEther24P10BT
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 631 }
|
|
|
|
-- C100 Multimode fiber MDA
|
|
s5ChasComMod-C100ATMMultiModeMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 632 }
|
|
-- C100 Unshielded twisted pair MDA
|
|
s5ChasComMod-C100ATMUTPMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 633 }
|
|
-- C100 Singlemode Fiber MDA
|
|
s5ChasComMod-C100ATMSingleModeMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 634 }
|
|
-- C100 DS3 MDA
|
|
s5ChasComMod-C100ATMDS3Mda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 635 }
|
|
-- C100 E3 MDA
|
|
s5ChasComMod-C100ATME3Mda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 636 }
|
|
|
|
-- 5000BH Token Ring 24 Port Host
|
|
s5ChasComBrdTR24PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 637 }
|
|
|
|
-- C100 Token Ring 16 Port Host
|
|
s5ChasComBrd-C100TR16PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 638 }
|
|
|
|
-- 5000BH 57622M-SM 1 Port 622 Mbps 0C12-C ATM SMF MCP Module
|
|
s5ChasComBrd57622M-SM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 645 }
|
|
|
|
-- 5000BH 57622M-MM 1 Port 622 Mbps 0C12-C ATM MMF MCP Module
|
|
s5ChasComBrd57622M-MM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 646 }
|
|
|
|
-- 5000BH 57622-MM 1 Port 622 Mbps 0C12-C ATM MMF Switch Host
|
|
s5ChasComBrd57622-MM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 647 }
|
|
|
|
-- C100 1 Port 622 Mbps 0C12-C ATM SMF MCP Module
|
|
s5ChasComBrd-C100ATMMCP1PSM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 648 }
|
|
|
|
-- C100 1 Port 622 Mbps 0C12-C ATM MMF MCP Module
|
|
s5ChasComBrd-C100ATMMCP1PMM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 649 }
|
|
|
|
-- C100 1 Port 622 Mbps 0C12-C ATM MMF Switch Host
|
|
s5ChasComBrd-C100ATM1PMM
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 650 }
|
|
|
|
s5ChasComBrdBayStack450-24T -- BayStack450-24T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 653 }
|
|
s5ChasComBrdBayStack450-24TStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-24T 0 }
|
|
s5ChasComBrdBayStack450-24TStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-24TStore 1 }
|
|
s5ChasComBrdBayStack450-24TStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-24TStore 2 }
|
|
s5ChasComBrdBayStack450-24TStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-24TStore 3 }
|
|
|
|
s5ChasComBrdBayStack450-12T -- BayStack450-12T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 654 }
|
|
s5ChasComBrdBayStack450-12TStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-12T 0 }
|
|
s5ChasComBrdBayStack450-12TStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-12TStore 1 }
|
|
s5ChasComBrdBayStack450-12TStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-12TStore 2 }
|
|
s5ChasComBrdBayStack450-12TStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-12TStore 3 }
|
|
|
|
s5ChasComBrdBayStack410-24T -- BayStack410-24T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 655 }
|
|
|
|
s5ChasComBrdBayStack450-1SX -- 1 port 1000Base-SX MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 656 }
|
|
|
|
s5ChasComBrdBayStack450-1SR -- 1 port 1000Base-SX MDA with LinkSafe
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 657 }
|
|
|
|
s5ChasComBrdBayStack400-4TX -- 4 port 10/100 autosense MDA with RJ/45 connectors
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 658 }
|
|
|
|
s5ChasComBrdBayStack400-2FX -- 2 port 100Base-FX MDA with SC connectors
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 659 }
|
|
|
|
s5ChasComBrdBayStack400-ST1 -- Stacking MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 660 }
|
|
|
|
s5ChasComBrdBayStack400-ST2 -- Dual ring stacking MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 661 }
|
|
|
|
s5ChasComBrdBayStack450-1LX -- 1 port 1000Base-LX MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 662 }
|
|
|
|
s5ChasComBrdBayStack450-1LR -- 1 port 1000Base-LX MDA with LinkSafe
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 663 }
|
|
|
|
s5ChasComBrdBayStack450-2SX -- 2 port 1000Base-SX MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 664 }
|
|
|
|
s5ChasComBrdBayStack450-2LX -- 2 port 1000Base-LX MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 665 }
|
|
|
|
s5ChasComBrdBayStack450-OC3 -- 2 port 155 Mbps OC3 Multi Mode ATM MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 666 }
|
|
|
|
-- BayStack 450-24TQP Chameleon 200 or 201 designated as "QP" to
|
|
-- differentiate from BayStack 450-24T Chameleon 100
|
|
s5ChasComBrdBayStack450-24TQP -- quad phy
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 667 }
|
|
|
|
s5ChasComBrdBPS2000-24T -- BPS 2000-24T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 668 }
|
|
s5ChasComBrdBPS2000-24TStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBPS2000-24T 0 }
|
|
s5ChasComBrdBPS2000-24TStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBPS2000-24TStore 1 }
|
|
s5ChasComBrdBPS2000-24TStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBPS2000-24TStore 2 }
|
|
s5ChasComBrdBPS2000-24TStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBPS2000-24TStore 3 }
|
|
|
|
-- 5000BH Model 5424 24 Port 100BaseFx Host
|
|
s5ChasComBrd5424
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 669 }
|
|
|
|
-- BayStack 525 Token Ring Switch
|
|
s5ChasComBrdBayStack525
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 670 }
|
|
|
|
-- BayStack 350-24T (Non-Stackable) Chameleon 100
|
|
s5ChasComBrdBayStack350-24T -- BayStack350-24T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 671 }
|
|
s5ChasComBrdBayStack350-24TStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-24T 0 }
|
|
s5ChasComBrdBayStack350-24TStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-24TStore 1 }
|
|
s5ChasComBrdBayStack350-24TStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-24TStore 2 }
|
|
s5ChasComBrdBayStack350-24TStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-24TStore 3 }
|
|
|
|
-- BayStack 350-12T (Non-Stackable) Chameleon 100
|
|
s5ChasComBrdBayStack350-12T -- BayStack350-12T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 672 }
|
|
s5ChasComBrdBayStack350-12TStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-12T 0 }
|
|
s5ChasComBrdBayStack350-12TStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-12TStore 1 }
|
|
s5ChasComBrdBayStack350-12TStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-12TStore 2 }
|
|
s5ChasComBrdBayStack350-12TStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-12TStore 3 }
|
|
|
|
-- BayStack250 24 port NMM Host Unit Repeater Brd
|
|
s5ChasComBrdBayStack253
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 673 }
|
|
|
|
-- BayStack 450-12TQP Chameleon 200 or 201 designated as "QP" to
|
|
-- differentiate from BayStack 450-12T Chameleon 100
|
|
s5ChasComBrdBayStack450-12TQP -- quad phy
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 674 }
|
|
|
|
-- BayStack 350-24TQP (Non-Stackable) Chameleon 200 or 201
|
|
-- The official product name is BayStack 350-24T. Registered here as "QP"
|
|
-- to avoid naming conflict with Chameleon 100 BayStack 350-24T
|
|
s5ChasComBrdBayStack350-24TQP -- BayStack350-24TQP
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 675 }
|
|
s5ChasComBrdBayStack350-24TQPStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-24TQP 0 }
|
|
s5ChasComBrdBayStack350-24TQPStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-24TQPStore 1 }
|
|
s5ChasComBrdBayStack350-24TQPStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-24TQPStore 2 }
|
|
s5ChasComBrdBayStack350-24TQPStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-24TQPStore 3 }
|
|
|
|
-- BayStack 350-12TQP (Non-Stackable) Chameleon 200 or 201
|
|
-- The official product name is BayStack 350-12T. Registered here as "QP"
|
|
-- to avoid naming conflict with Chameleon 100 BayStack 350-12T
|
|
s5ChasComBrdBayStack350-12TQP -- BayStack350-12TQP
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 676 }
|
|
s5ChasComBrdBayStack350-12TQPStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-12TQP 0 }
|
|
s5ChasComBrdBayStack350-12TQPStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-12TQPStore 1 }
|
|
s5ChasComBrdBayStack350-12TQPStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-12TQPStore 2 }
|
|
s5ChasComBrdBayStack350-12TQPStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack350-12TQPStore 3 }
|
|
|
|
-- BayStack 450-12F "Firefly" 12 Fiber Ports + MDA Slot
|
|
s5ChasComBrdBayStack450-12F -- BayStack450-12F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 681 }
|
|
s5ChasComBrdBayStack450-12FStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-12F 0 }
|
|
s5ChasComBrdBayStack450-12FStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-12FStore 1 }
|
|
s5ChasComBrdBayStack450-12FStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-12FStore 2 }
|
|
s5ChasComBrdBayStack450-12FStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-12FStore 3 }
|
|
|
|
s5ChasComBrdBayStack400-4FX -- 4 port 100Base-FX MDA with MT-RJ connectors
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 682 }
|
|
|
|
-- BayStack 303-24T 24+1 10BASE-T/100BASE-T Switch with 2 MDA
|
|
s5ChasComMBayStack303-24T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 691 }
|
|
|
|
-- BayStack 253 10/100 Hub 100Base-FX Media Adapter
|
|
s5ChasComBrdBayStack-100FxMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 692 }
|
|
|
|
-- Accelar 8010 chassis 32 port 10/100 switch host module with MDA slot
|
|
s5ChasComBrdAccelar8132TX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 693 }
|
|
|
|
-- Accelar 8010 chassis 48 port 10/100 switch host module
|
|
s5ChasComBrdAccelar8148TX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 694 }
|
|
|
|
-- BayStack250 12 port Slave Unit Repeater Brd
|
|
s5ChasComBrdBayStack254
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 695 }
|
|
|
|
-- BayStack250 24 port Slave Unit Repeater Brd
|
|
s5ChasComBrdBayStack255
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 696 }
|
|
|
|
-- 1 port 100Base-FX MDA for BayStack 25x 10/100 Hub
|
|
s5ChasComBrdBayStack25x-100FxMda
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 697 }
|
|
|
|
-- 5000BH Model 5625HD 24-port 10/100 Ethernet Copper Switch Host
|
|
s5ChasComBrdM5625HD
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 701 }
|
|
|
|
-- 5000BH Model 5424HD 24-port 100BaseFX Switch Host
|
|
s5ChasComBrdM5424HD
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 702 }
|
|
|
|
-- C50/C100 20-port 10/100 Ethernet Copper Switch Host
|
|
s5ChasComMod-C100mEther20PC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 703 }
|
|
|
|
-- C50/C100 16-port 100BaseFX Switch Host
|
|
s5ChasComMod-C100mEther16P100FX
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 704 }
|
|
|
|
s5ChasComBrdBayStack670 -- BayStack670 11 Mb/s wireless access point
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 705 }
|
|
s5ChasComBrdBayStack670Store -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack670 0 }
|
|
s5ChasComBrdBayStack670StoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack670Store 1 }
|
|
|
|
-- 500xBH Model 5420 3-port GBIC Ethernet Switch Module
|
|
s5ChasComBrdM5420
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 706 }
|
|
|
|
-- C50/C100 3-port EtherSpeedII GBIC Switch Module
|
|
s5ChasComMod-C100mEther3PGBIC
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 707 }
|
|
|
|
s5ChasComBrdBPS2000-4TX -- 4 port 10/100 MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 708 }
|
|
|
|
s5ChasComBrdBPS2000-4FX -- 4 port 100Base-FX MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 709 }
|
|
|
|
s5ChasComBrdBPS2000-2FX -- 2 port 100Base-FX MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 710 }
|
|
|
|
s5ChasComBrdBayStack3580-16F -- BayStack3580-16F
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 711 }
|
|
s5ChasComBrdBayStack3580-16FStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack3580-16F 0 }
|
|
s5ChasComBrdBayStack3580-16FStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack3580-16FStore 1 }
|
|
s5ChasComBrdBayStack3580-16FStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack3580-16FStore 2 }
|
|
s5ChasComBrdBayStack3580-16FStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack3580-16FStore 3 }
|
|
|
|
-- BayStack 450 ATM MDAs. There is also an s5ChasComBrdBayStack450-OC3
|
|
-- defined above as:
|
|
--
|
|
|
|
s5ChasComBrdBayStack450-OC3S -- 2 port 155 Mbps OC3 Single Mode ATM MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 717 }
|
|
|
|
s5ChasComBrdBayStack450-OC12 -- 2 port 622 Mbps OC12 Multi Mode ATM MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 718 }
|
|
|
|
s5ChasComBrdBayStack450-OC12S -- 2 port 622 Mbps OC12 Single Mode ATM MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 719 }
|
|
|
|
-- BayStack 420-24T 24-Port 10/100 Ethernet Switch
|
|
s5ChasComBrdBayStack420-24T -- BayStack420-24T
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 720 }
|
|
s5ChasComBrdBayStack420-24TStore -- storage areas
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack420-24T 0 }
|
|
s5ChasComBrdBayStack420-24TStoreFlash -- FLASH image storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack420-24TStore 1 }
|
|
s5ChasComBrdBayStack420-24TStoreBootFW -- Boot Firmware storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack420-24TStore 2 }
|
|
s5ChasComBrdBayStack420-24TStoreDram -- DRAM storage
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack420-24TStore 3 }
|
|
|
|
-- BayStack 450 and BPS2000 1 port 1 Phy packet bus II GBIC MDA.
|
|
s5ChasComBrdBayStack450-GBIC -- BayStack 450 and BPS2000 single port single Phy GBIC MDA
|
|
OBJECT IDENTIFIER ::= { s5ChasComMod 721 }
|
|
s5ChasComBrdBayStack450-GBICno -- No Transceiver present
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-GBIC 1 }
|
|
s5ChasComBrdBayStack450-GBICun -- Unsupported Transceiver
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-GBIC 2 }
|
|
s5ChasComBrdBayStack450-GBICsx -- Short Distance
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-GBIC 3 }
|
|
s5ChasComBrdBayStack450-GBIClx -- Long Distance
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-GBIC 4 }
|
|
s5ChasComBrdBayStack450-GBICzx -- 50 Kilometers
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-GBIC 5 }
|
|
s5ChasComBrdBayStack450-GBICxd -- 70 Kilometers
|
|
OBJECT IDENTIFIER ::= { s5ChasComBrdBayStack450-GBIC 6 }
|
|
|
|
END
|