-- SECTION 1: Top Level Definitions
|
|
|
|
S5-ETH-REDUNDANT-LINKS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
-- 5000 Ethernet Redundant Links MIB Release 1.0.2
|
|
-- Revision 03/14/95
|
|
|
|
-- Copyright 1995 Bay Networks, Inc.
|
|
-- All rights reserved.
|
|
-- This Bay Networks SNMP Management Information Base Specification
|
|
-- (Specification) embodies Bay Networks' confidential and
|
|
-- proprietary intellectual property. Bay Networks retains all
|
|
-- title and ownership in the Specification, including any
|
|
-- revisions.
|
|
|
|
-- This Specification is supplied "AS IS," and Bay Networks makes
|
|
-- no warranty, either express or implied, as to the use,
|
|
-- operation, condition, or performance of the Specification.
|
|
|
|
|
|
|
|
|
|
-- Imports
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
s5EnCfg
|
|
FROM S5-ETHERNET-MIB
|
|
TimeTicks, Counter
|
|
FROM RFC1155-SMI
|
|
TimeIntervalSec
|
|
FROM S5-TCS-MIB;
|
|
|
|
|
|
-- Groups
|
|
|
|
s5EnRedun OBJECT IDENTIFIER ::= { s5EnCfg 2 }
|
|
|
|
|
|
|
|
-- SECTION 2: Redundant Port Information
|
|
|
|
-- Redundant Port Table
|
|
|
|
s5EnRedPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5EnRedPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table with redundancy status and control for
|
|
each redundancy-capable port in the chassis.
|
|
The number of entries is determined by the number
|
|
of redundancy-capable ports in the chassis.
|
|
|
|
The ports appearing in this table can be divided into
|
|
two categories:
|
|
Those with remote fault signaling capability and
|
|
those without. The latter kind depends on the port
|
|
link status to provide the required redundancy.
|
|
|
|
Ports that are not capable of supporting redundancy do
|
|
not have an entry in this table."
|
|
::= { s5EnRedun 1 }
|
|
|
|
s5EnRedPortEntry OBJECT-TYPE
|
|
SYNTAX S5EnRedPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A row in the table of redundancy status and
|
|
control for each redundancy-capable port in the
|
|
chassis. Entries in the table cannot be
|
|
created or deleted via SNMP."
|
|
INDEX { s5EnRedPortBrdIndx,
|
|
s5EnRedPortPortIndx }
|
|
::= { s5EnRedPortTable 1 }
|
|
|
|
S5EnRedPortEntry ::= SEQUENCE {
|
|
s5EnRedPortBrdIndx
|
|
INTEGER,
|
|
s5EnRedPortPortIndx
|
|
INTEGER,
|
|
s5EnRedPortCapability
|
|
INTEGER,
|
|
s5EnRedPortRedundMode
|
|
INTEGER,
|
|
s5EnRedPortOperStatus
|
|
INTEGER,
|
|
s5EnRedPortRemoteOperStatus
|
|
INTEGER,
|
|
s5EnRedPortRemFltSelectMode
|
|
INTEGER,
|
|
s5EnRedPortTxMode
|
|
INTEGER,
|
|
s5EnRedPortFaults
|
|
Counter,
|
|
s5EnRedPortModeChanges
|
|
Counter,
|
|
s5EnRedPortCompanionBrdNum
|
|
INTEGER,
|
|
s5EnRedPortCompanionPortNum
|
|
INTEGER,
|
|
s5EnRedPortSwitchoverStatus
|
|
INTEGER,
|
|
s5EnRedPortSwitchoverTime
|
|
TimeIntervalSec
|
|
}
|
|
|
|
s5EnRedPortBrdIndx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the slot containing the board on which
|
|
the port is located."
|
|
::= { s5EnRedPortEntry 1 }
|
|
|
|
s5EnRedPortPortIndx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the port on the board."
|
|
::= { s5EnRedPortEntry 2 }
|
|
|
|
s5EnRedPortCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
hwRedOnly(1),
|
|
swRedOnly(2),
|
|
hwAndSwRed(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The redundancy capability of the port:
|
|
hwRedOnly(1).....hardware redundancy only.
|
|
swRedOnly(2).....software redundacy only.
|
|
hwAndSwRed(3)....both hardware and software redundancy.
|
|
|
|
A value of hwRedOnly(1) or hwAndSwRed(3) means that
|
|
the port is capable of being configured into a
|
|
hardware-redundant pair. In this case, the identity of the
|
|
potential redundant companion is given by the objects
|
|
s5EnRedPortCompanionBrdNum and s5EnRedPortCompanionPortNum.
|
|
|
|
A value of swRedOnly(2) or hwAndSwRed(3) means that
|
|
the port is capable of being configured into a
|
|
software-redundant pair."
|
|
::= { s5EnRedPortEntry 3 }
|
|
|
|
s5EnRedPortRedundMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standAlone(1),
|
|
hwActive(2),
|
|
hwStandby(3),
|
|
swActive(4),
|
|
swStandby(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The redundancy mode of the port.
|
|
|
|
The values when written change the redundancy
|
|
mode, and when read report the redundancy mode:
|
|
standalone(1)..the port is not in any redundant pair.
|
|
hwActive(2)....the port is the active companion in
|
|
a hardware-redundant pair.
|
|
hwStandby(3)...the port is the standby companion
|
|
in a hardware-redundant pair.
|
|
swActive(4)....the port is the active companion in
|
|
a software-redundant pair.
|
|
swStandby(5)...the port is the standby companion
|
|
in a software-redundant pair.
|
|
|
|
The values that can be written, which change the
|
|
redundancy mode, are:
|
|
standalone(1)...causes the redundant pair to be
|
|
broken up.
|
|
hwActive(2).....if the previous value was hwStandby(3),
|
|
this value will cause the port to become
|
|
the active port in the hardware-redundant
|
|
pair, resulting in a switchover.
|
|
hwStandby(3)....if the previous value was hwActive(2),
|
|
this value will cause the port to become
|
|
the standby port in the hardware-redundant
|
|
pair, resulting in a switchover.
|
|
swActive(4).....if the previous value was swStandby(5),
|
|
this value will cause the port to become
|
|
the active port in the software-redundant
|
|
pair, resulting in a switchover.
|
|
swStandby(5)....if the previous value was swActive(4),
|
|
this value will cause the port to become
|
|
the standby port in the software-redundant
|
|
pair, resulting in a switchover.
|
|
|
|
To create a hardware-redundant pair, change this object
|
|
to hwActive(2) or hwStandby(3). To create a
|
|
software-redundant pair, change this object to
|
|
swActive(4) or swStandby(5). The same SNMP SET PDU
|
|
must also write to objects s5EnRedPortCompanionBrdNum
|
|
and s5EnRedPortCompanionPortNum."
|
|
::= { s5EnRedPortEntry 4 }
|
|
|
|
s5EnRedPortOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
localFault(3),
|
|
remoteFault(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The redundancy status of the port. The values are:
|
|
other(1).............none of the following.
|
|
ok(2)...................no fault
|
|
localFault(3)....the local port has sensed a fault condition.
|
|
remoteFault(4)...the remote port has sensed a fault
|
|
condition and has signaled the local port
|
|
accordingly.
|
|
|
|
Either a localFault(3) or remoteFault(4) condition should
|
|
cause a healthy redundant port pair to switchover.
|
|
If the port does not belong to a redundant pair, a
|
|
value of other(1) is returned.
|
|
|
|
Note: If the redundant link consists of ports without
|
|
remote fault capability, the value remoteFault(4)
|
|
will not be reported and the value localFault(3)
|
|
implies that link is off."
|
|
::= { s5EnRedPortEntry 5 }
|
|
|
|
s5EnRedPortRemoteOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
snpxFLRemFltCpblPortUp(1),
|
|
snpxFLFBRemFltCpblPortUp(2),
|
|
tenBaseTFLPortUp(3),
|
|
tenBaseFBPortUp(4),
|
|
snpxRemFltCpblPortFault(5),
|
|
tenBaseFBPortFault(6),
|
|
unknown(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object reflects the real time status of the
|
|
received data from the remote port. The values are:
|
|
|
|
snpxFLRemFltCpblPortUp(1)....10BASE-FL signaling,
|
|
plus capable of SynOptics proprietary
|
|
remote fault signaling. A remote fault
|
|
on such a port is indicated by
|
|
snpxRemFltCpblPortFault(5).
|
|
snpxFLFBRemFltCpblPortUp(2)..10BASE-FL signaling,
|
|
plus capable of SynOptics proprietary
|
|
remote fault signaling and 10BASE-FB
|
|
signaling. A remote fault on such a port
|
|
is indicated by snpxRemFltCpblPortFault(5).
|
|
tenBaseTFLPortUp(3)...........regular idle 10BASE-T
|
|
or 10BASE-FL signaling, and is incapable of
|
|
remote fault signaling.
|
|
tenBaseFBPortUp(4)...........10BASE-FB synchronous
|
|
signaling. A remote fault on such a port is
|
|
indicated by tenBaseFBPortFault(6).
|
|
snpxRemFltCpblPortFault(5)...SynOptics proprietary
|
|
remote fault signaling.
|
|
tenBaseFBPortFault(6)........10BASE-FB remote fault
|
|
signaling.
|
|
unknown(7)...................none of the above.
|
|
|
|
A value of snpxFLRemFltCpblPortUp(1) indicates that
|
|
the remote port is using 10BASE-FL signaling, and is
|
|
capable of SynOptics proprietary idle and remote fault
|
|
signaling. A remote fault on such a port is indicated
|
|
by snpxRemFltCpblPortFault(5).
|
|
|
|
A value of snpxFLFBRemFltCpblPortUp(2) indicates that
|
|
the remote port is using 10BASE-FL signaling, and is
|
|
capable of SynOptics proprietary idle and remote fault
|
|
signaling, and is also capable of synchronous
|
|
signaling. A remote fault on such a port is indicated
|
|
by snpxRemFltCpblPortFault(5).
|
|
|
|
A value of tenBaseFLPortUp(3) indicates that the
|
|
remote port uses regular idle 10BASE-FL signaling, and
|
|
is incapable of remote fault signaling.
|
|
|
|
A value of tenBaseFBPortUp(4) indicates that the
|
|
remote port uses 10BASE-FB synchronous signaling. A
|
|
remote fault on such a port is indicated by
|
|
tenBaseFBPortFault(6)."
|
|
::= { s5EnRedPortEntry 6 }
|
|
|
|
s5EnRedPortRemFltSelectMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
synoptics(1),
|
|
standard(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This mode specifies the set of local fault events
|
|
which will cause a switchover. The values are:
|
|
synoptics(1)..The SynOptics Tx Remote Fault events
|
|
consist of auto-partition and NM (network
|
|
management) partition events in addition to
|
|
the standard events.
|
|
standard(2)...The standard events are link-off for
|
|
all ports, and low light, jabber, Rx invalid idle,
|
|
Tx dark, and Tx remote fault (for diagnostics)
|
|
for ports with transmit remote fault
|
|
capability."
|
|
::= { s5EnRedPortEntry 7 }
|
|
|
|
s5EnRedPortTxMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
autoCfg(1),
|
|
fl(2),
|
|
fb(3),
|
|
other(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Transmit Fiber Mode, which determines the
|
|
port transmit idle. The values are:
|
|
autoCfg(1)...The port will auto configure based
|
|
upon the received idle.
|
|
fl(2)........The port is configured in FL mode.
|
|
fb(3)........The port is configured in FB mode.
|
|
other(4).....None of the above. The port is not a fiber
|
|
port.
|
|
|
|
The value other(4) is read-only."
|
|
::= { s5EnRedPortEntry 8 }
|
|
|
|
s5EnRedPortFaults OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of local or remote faults on this port. This
|
|
counter increments on a transition between the fault
|
|
and no-fault states."
|
|
::= { s5EnRedPortEntry 9 }
|
|
|
|
s5EnRedPortModeChanges OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of the number of times this port has transitioned
|
|
from standby mode to non-standby mode (includes active
|
|
mode and standalone mode), or vice versa."
|
|
::= { s5EnRedPortEntry 10 }
|
|
|
|
s5EnRedPortCompanionBrdNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the slot containing the board of the
|
|
other port in the redundant pair.
|
|
|
|
If the port (whose slot-port identity is given by
|
|
the instance) is hardware-redundant capable, this
|
|
object has the value of the slot number of the
|
|
(potential) redundant companion, even if the port is
|
|
in standalone mode. This allows the network
|
|
manager to determine the identity of the potential
|
|
companion, which is fixed by the hardware of the
|
|
board.
|
|
|
|
Changing this object is permitted only when creating a
|
|
software-redundant pair."
|
|
::= { s5EnRedPortEntry 11 }
|
|
|
|
s5EnRedPortCompanionPortNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the other port in the redundant pair.
|
|
|
|
If the port (whose slot-port identity is given by
|
|
the instance) is hardware-redundant capable, this object
|
|
has the value of the port number of the (potential)
|
|
redundant companion, even if the port is in standalone
|
|
mode. This allows the network manager to determine
|
|
the identity of the potential companion, which is fixed
|
|
by the hardware of the board.
|
|
|
|
Changing this object is permitted only when creating a
|
|
software-redundant pair."
|
|
::= { s5EnRedPortEntry 12 }
|
|
|
|
s5EnRedPortSwitchoverStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
timedSwitchover(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switchover status of the port (and its companion).
|
|
The following values can be written:
|
|
timedSwitchover(2)...cause a timed switchover
|
|
(see value of
|
|
s5EnRedPortSwitchoverTime)
|
|
|
|
The following values reflect the switchover
|
|
status of the redundant port pair:
|
|
other(1)..............not undergoing switchover
|
|
timedSwitchover(2)....port is undergoing timed switchover
|
|
(see value of
|
|
s5EnRedPortSwitchoverTime).
|
|
|
|
On GETs with switchover status of timedSwitchover(2),
|
|
if the time remaining before the completion of the
|
|
switchover and reversal is available, it will be reported
|
|
in object s5EnRedPortSwitchoverTime as a positive value
|
|
If not available, the value of s5EnRedSwitchoverTime will
|
|
be zero. When changing a port to timedSwitchover(2), the
|
|
SET request must also contain the value for object
|
|
s5EnRedSwitchoverTime."
|
|
::= { s5EnRedPortEntry 13 }
|
|
|
|
s5EnRedPortSwitchoverTime OBJECT-TYPE
|
|
SYNTAX TimeIntervalSec (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length of time between switching over a redundant
|
|
port pair and switching back, when a timed switchover
|
|
is done to the port. This object can only be written
|
|
in the same request that sets
|
|
s5EnRedPortSwitchoverStatus to timedSwitchover(2).
|
|
Afterwards, it indicates the amount of time left
|
|
before the timed switchover is completed, at which
|
|
time another switchover occurs and
|
|
s5EnRedSwitchoverStatus is changed to other(1). This
|
|
object has the value of zero if the port is not
|
|
undergoing a timed switchover, or if the amount of
|
|
time is not available."
|
|
::= { s5EnRedPortEntry 14 }
|
|
|
|
|
|
-- Last Change To Table Object
|
|
|
|
s5EnRedLastChg OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the last change in the
|
|
redundant ports table was observed by the agent."
|
|
::= { s5EnRedun 2}
|
|
|
|
END
|