#-MIBFILE: cpqrack.mib
|
|
|
|
CPQRACK-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
DisplayString ::=
|
|
OCTET STRING
|
|
|
|
PhysAddress ::=
|
|
OCTET STRING
|
|
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
system OBJECT IDENTIFIER ::= { mib-2 1 }
|
|
sysName OBJECT IDENTIFIER ::= { system 5 }
|
|
cpqHostOs OBJECT IDENTIFIER ::= { compaq 11 }
|
|
cpqHoComponent OBJECT IDENTIFIER ::= { cpqHostOs 2 }
|
|
cpqHoTrapInfo OBJECT IDENTIFIER ::= { cpqHoComponent 11 }
|
|
cpqHoTrapFlags OBJECT IDENTIFIER ::= { cpqHoTrapInfo 1 }
|
|
cpqRackInfo OBJECT IDENTIFIER ::= { compaq 22 }
|
|
|
|
cpqRackMibRev OBJECT IDENTIFIER ::= { cpqRackInfo 1 }
|
|
|
|
cpqRackComponent OBJECT IDENTIFIER ::= { cpqRackInfo 2 }
|
|
|
|
cpqRackSysObjID OBJECT IDENTIFIER ::= { cpqRackInfo 3 }
|
|
|
|
cpqRackInterface OBJECT IDENTIFIER ::= { cpqRackComponent 1 }
|
|
|
|
cpqRackAsset OBJECT IDENTIFIER ::= { cpqRackComponent 2 }
|
|
|
|
cpqRackEnclosure OBJECT IDENTIFIER ::= { cpqRackComponent 3 }
|
|
|
|
cpqRackServer OBJECT IDENTIFIER ::= { cpqRackComponent 4 }
|
|
|
|
cpqRackPower OBJECT IDENTIFIER ::= { cpqRackComponent 5 }
|
|
|
|
cpqRackNetwork OBJECT IDENTIFIER ::= { cpqRackComponent 6 }
|
|
|
|
cpqRackOsCommon OBJECT IDENTIFIER ::= { cpqRackInterface 4 }
|
|
|
|
cpqRackCommonEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 1 }
|
|
|
|
cpqRackServerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 2 }
|
|
|
|
cpqRackPowerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 3 }
|
|
|
|
cpqRackServerBlade OBJECT IDENTIFIER ::= { cpqRackServer 1 }
|
|
|
|
cpqRackServerNetworking OBJECT IDENTIFIER ::= { cpqRackServer 2 }
|
|
|
|
cpqRackServerTempSensor OBJECT IDENTIFIER ::= { cpqRackServer 3 }
|
|
|
|
cpqRackPowerSupply OBJECT IDENTIFIER ::= { cpqRackPower 1 }
|
|
|
|
cpqRackNetConnector OBJECT IDENTIFIER ::= { cpqRackNetwork 1 }
|
|
|
|
cpqRackMibRevMajor OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The major revision level of the MIB.
|
|
|
|
A change in the major revision level represents a major change
|
|
in the architecture of the MIB. A change in the major revision
|
|
level may indicate a significant change in the information
|
|
supported and/or the meaning of the supported information,
|
|
correct interpretation of data may require a MIB document with
|
|
the same major revision level."
|
|
::= { cpqRackMibRev 1 }
|
|
|
|
|
|
cpqRackMibRevMinor OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The minor revision level of the MIB.
|
|
|
|
A change in the minor revision level may represent some minor
|
|
additional support, no changes to any pre-existing information
|
|
has occurred."
|
|
::= { cpqRackMibRev 2 }
|
|
|
|
|
|
cpqRackMibCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall condition.
|
|
|
|
This object represents the overall status of the
|
|
rack information represented by this MIB."
|
|
::= { cpqRackMibRev 3 }
|
|
|
|
|
|
cpqRackOsCommonPollFreq OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Management Agent's polling frequency.
|
|
|
|
The frequency, in seconds, at which the Agent requests
|
|
information from the device driver. A frequency of zero (0)
|
|
indicates that the Insight Agent retrieves the information upon
|
|
request of a management station, it does not poll the device
|
|
driver at a specific interval.
|
|
|
|
If the poll frequency is zero (0) all attempts to write to this
|
|
object will fail. If the poll frequency is non-zero,
|
|
setting this value will change the polling frequency of the
|
|
Insight Agent. Setting the poll frequency to zero (0) will
|
|
always fail, an agent may also choose to fail any request to
|
|
change the poll frequency to a value that would severely impact
|
|
system performance."
|
|
::= { cpqRackOsCommon 1 }
|
|
|
|
|
|
cpqRackAssetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackAssetEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack asset information."
|
|
::= { cpqRackAsset 1 }
|
|
|
|
|
|
cpqRackAssetEntry OBJECT-TYPE
|
|
SYNTAX CpqRackAssetEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack asset description."
|
|
INDEX { cpqRackAssetIndex }
|
|
|
|
::= { cpqRackAssetTable 1 }
|
|
|
|
cpqRackAssetEntry ::=
|
|
SEQUENCE {
|
|
cpqRackAssetIndex INTEGER,
|
|
cpqRackName DisplayString,
|
|
cpqRackUid DisplayString,
|
|
cpqRackSerialNum DisplayString,
|
|
cpqRackTrapSequenceNum INTEGER,
|
|
cpqRackHeight INTEGER,
|
|
cpqRackWidth INTEGER,
|
|
cpqRackDepth INTEGER
|
|
}
|
|
|
|
cpqRackAssetIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack table entry."
|
|
::= { cpqRackAssetEntry 1 }
|
|
|
|
|
|
cpqRackName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The customer changeable identifier used to identify the entire
|
|
rack.
|
|
|
|
The string will be empty if the system does not report this
|
|
function."
|
|
::= { cpqRackAssetEntry 2 }
|
|
|
|
|
|
cpqRackUid OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The rack unique identifier.
|
|
|
|
The string will be empty if the rack does not report the
|
|
UID or if it could not be determined."
|
|
::= { cpqRackAssetEntry 3 }
|
|
|
|
|
|
cpqRackSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The rack serial number.
|
|
|
|
The string will be empty if the rack does not report the
|
|
serial number."
|
|
::= { cpqRackAssetEntry 4 }
|
|
|
|
|
|
cpqRackTrapSequenceNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The trap sequence number for rack traps.
|
|
|
|
This is used by the management application trap processing.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackAssetEntry 5 }
|
|
|
|
|
|
cpqRackHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The internal height dimension of the useable rack space expressed
|
|
in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackAssetEntry 6 }
|
|
|
|
|
|
cpqRackWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The internal width dimension of the useable rack space expressed
|
|
in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackAssetEntry 7 }
|
|
|
|
|
|
cpqRackDepth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The internal depth dimension of the useable rack space expressed
|
|
in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackAssetEntry 8 }
|
|
|
|
|
|
cpqRackCommonEnclosureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack enclosure information."
|
|
::= { cpqRackCommonEnclosure 1 }
|
|
|
|
|
|
cpqRackCommonEnclosureEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack enclosure description."
|
|
INDEX { cpqRackCommonEnclosureRack , cpqRackCommonEnclosureIndex }
|
|
|
|
::= { cpqRackCommonEnclosureTable 1 }
|
|
|
|
cpqRackCommonEnclosureEntry ::=
|
|
SEQUENCE {
|
|
cpqRackCommonEnclosureRack INTEGER,
|
|
cpqRackCommonEnclosureIndex INTEGER,
|
|
cpqRackCommonEnclosureModel DisplayString,
|
|
cpqRackCommonEnclosureAssetTag DisplayString,
|
|
cpqRackCommonEnclosurePartNumber DisplayString,
|
|
cpqRackCommonEnclosureSparePartNumber DisplayString,
|
|
cpqRackCommonEnclosureSerialNum DisplayString,
|
|
cpqRackCommonEnclosureFWRev DisplayString,
|
|
cpqRackCommonEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureNeighborNamePrev DisplayString,
|
|
cpqRackCommonEnclosureNeighborNameNext DisplayString,
|
|
cpqRackCommonEnclosureHeight INTEGER,
|
|
cpqRackCommonEnclosureWidth INTEGER,
|
|
cpqRackCommonEnclosureDepth INTEGER,
|
|
cpqRackCommonEnclosureTrapSequenceNum INTEGER,
|
|
cpqRackCommonEnclosureCondition INTEGER,
|
|
cpqRackCommonEnclosureHasServerBlades INTEGER,
|
|
cpqRackCommonEnclosureHasPowerSupplies INTEGER,
|
|
cpqRackCommonEnclosureHasNetConnectors INTEGER,
|
|
cpqRackCommonEnclosureHasTempSensors INTEGER,
|
|
cpqRackCommonEnclosureHasFans INTEGER,
|
|
cpqRackCommonEnclosureHasFuses INTEGER,
|
|
cpqRackCommonEnclosureMgmtUID INTEGER,
|
|
cpqRackCommonEnclosureSerialNumPrev DisplayString,
|
|
cpqRackCommonEnclosureSerialNumNext DisplayString,
|
|
cpqRackCommonEnclosureAddress INTEGER,
|
|
cpqRackCommonEnclosureProductId DisplayString,
|
|
cpqRackCommonEnclosureProductIdPrev DisplayString,
|
|
cpqRackCommonEnclosureProductIdNext DisplayString,
|
|
cpqRackCommonEnclosureUUID DisplayString,
|
|
cpqRackCommonEnclosureUUIDPrev DisplayString,
|
|
cpqRackCommonEnclosureUUIDNext DisplayString,
|
|
cpqRackCommonEnclosureHasManagers INTEGER
|
|
}
|
|
|
|
cpqRackCommonEnclosureRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureEntry 1 }
|
|
|
|
|
|
cpqRackCommonEnclosureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureEntry 2 }
|
|
|
|
|
|
cpqRackCommonEnclosureModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The model name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
model information."
|
|
::= { cpqRackCommonEnclosureEntry 3 }
|
|
|
|
|
|
cpqRackCommonEnclosureAssetTag OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The customer changeable asset identifier of the enclosure.
|
|
|
|
The string will be empty if the system does not report this
|
|
function or if the asset tag has not been set."
|
|
::= { cpqRackCommonEnclosureEntry 4 }
|
|
|
|
|
|
cpqRackCommonEnclosurePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The part number of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
function."
|
|
::= { cpqRackCommonEnclosureEntry 5 }
|
|
|
|
|
|
cpqRackCommonEnclosureSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The spare part number of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
function."
|
|
::= { cpqRackCommonEnclosureEntry 6 }
|
|
|
|
|
|
cpqRackCommonEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number."
|
|
::= { cpqRackCommonEnclosureEntry 7 }
|
|
|
|
|
|
cpqRackCommonEnclosureFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware revision of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
firmware revision or does not contain firmware."
|
|
::= { cpqRackCommonEnclosureEntry 8 }
|
|
|
|
|
|
cpqRackCommonEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 9 }
|
|
|
|
|
|
cpqRackCommonEnclosureNeighborNamePrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure immediately preceding or above this
|
|
enclosure.
|
|
|
|
The string will be empty if the neighbor enclosure name could not be
|
|
determined or there is no enclosure preceding this one."
|
|
::= { cpqRackCommonEnclosureEntry 10 }
|
|
|
|
|
|
cpqRackCommonEnclosureNeighborNameNext OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure immediately following or below this
|
|
enclosure.
|
|
|
|
The string will be empty if the neighbor enclosure name could not be
|
|
determined or there is no enclosure following this one."
|
|
::= { cpqRackCommonEnclosureEntry 11 }
|
|
|
|
|
|
cpqRackCommonEnclosureHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The height dimension of the rack space taken by the
|
|
enclosure expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 12 }
|
|
|
|
|
|
cpqRackCommonEnclosureWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The width dimension of the rack space taken by the
|
|
enclosure expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 13 }
|
|
|
|
|
|
cpqRackCommonEnclosureDepth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The depth dimension of the rack space taken by the
|
|
enclosure expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 14 }
|
|
|
|
|
|
cpqRackCommonEnclosureTrapSequenceNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The trap sequence number for the enclosure.
|
|
|
|
This is used by the management application trap processing.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 15 }
|
|
|
|
|
|
cpqRackCommonEnclosureCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall condition of the enclosure.
|
|
|
|
This is the aggregate of the temperature sensors, fans, and
|
|
fuses within the enclosure.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
No temperature sensors, fans, or fuses in the enclosure or the
|
|
state could no be determined.
|
|
|
|
ok(2)
|
|
All temperature sensors, fans, and fuses are within the normal
|
|
operating range.
|
|
|
|
degraded(3)
|
|
One or more temperature sensors, fans, or fuses are outside of
|
|
the normal operating range. None are failed.
|
|
|
|
failed(4)
|
|
The temperature sensor exceeded the critical threshold value,
|
|
a required fan has failed, or a fuse has been tripped.
|
|
|
|
The system will automatically shutdown if the failed(4) condition
|
|
results, so it is unlikely that this value will ever be returned
|
|
by the agent."
|
|
::= { cpqRackCommonEnclosureEntry 16 }
|
|
|
|
|
|
cpqRackCommonEnclosureHasServerBlades OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The enclosure can contain server blades.
|
|
|
|
This will be true(2) is the enclosure can house server blades. The
|
|
cpqRackServerEnclosureTable will contain server enclosure specific
|
|
information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackServerEnclosureTable to get complete
|
|
information on the server enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 17 }
|
|
|
|
|
|
cpqRackCommonEnclosureHasPowerSupplies OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The enclosure can contain power supplies.
|
|
|
|
This will be true(2) is the enclosure can house power supplies. The
|
|
cpqRackEnclosurePowerTable will contain power enclosure specific
|
|
information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackEnclosurePowerTable to get complete
|
|
information on the power enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 18 }
|
|
|
|
|
|
cpqRackCommonEnclosureHasNetConnectors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The enclosure contains network connectivity.
|
|
|
|
This will be true(2) is the enclosure contains network connectivity.
|
|
The cpqRackCommonEnclosureNetConnectorTable will contain network
|
|
connectivity specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureNetConnectorTable to get complete
|
|
information on the network connector enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 19 }
|
|
|
|
|
|
cpqRackCommonEnclosureHasTempSensors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The enclosure contains temperature sensors.
|
|
|
|
This will be true(2) is the enclosure contains
|
|
temperature sensors. The cpqRackCommonEnclosureTempTable will
|
|
contain temperature sensor specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureTempTable to get complete
|
|
information on the enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 20 }
|
|
|
|
|
|
cpqRackCommonEnclosureHasFans OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The enclosure contains fans.
|
|
|
|
This will be true(2) is the enclosure contains fans.
|
|
The cpqRackCommonEnclosureFanTable will contain the fan
|
|
specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureFanTable to get complete
|
|
information on the enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 21 }
|
|
|
|
|
|
cpqRackCommonEnclosureHasFuses OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The enclosure contains fuses.
|
|
|
|
This will be true(2) is the enclosure contains fuses.
|
|
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
|
specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureFuseTable to get complete
|
|
information on the enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 22 }
|
|
|
|
|
|
cpqRackCommonEnclosureMgmtUID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
ledOn(3),
|
|
ledOff(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Unit Identifier LED.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
The state of the LED could not be determined. Setting the
|
|
LED state is not allowed.
|
|
|
|
none(2)
|
|
The LED is not present. Setting LED state is not allowed.
|
|
|
|
ledOn(3)
|
|
The LED is present and ON. The LED can be turned off
|
|
by setting the cpqRackCommonEnclosureMgmtUID to ledOff(4).
|
|
|
|
ledOff(4)
|
|
The LED is present and OFF. The LED can be turned on
|
|
by setting the cpqRackCommonEnclosureMgmtUID to ledOn(3)."
|
|
::= { cpqRackCommonEnclosureEntry 23 }
|
|
|
|
|
|
cpqRackCommonEnclosureSerialNumPrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure immediately preceding or
|
|
above this enclosure.
|
|
|
|
The string will be empty if the neighbor enclosure serial number
|
|
could not be determined or there is no enclosure preceding this one."
|
|
::= { cpqRackCommonEnclosureEntry 24 }
|
|
|
|
|
|
cpqRackCommonEnclosureSerialNumNext OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure immediately following or
|
|
below this enclosure.
|
|
|
|
The string will be empty if the neighbor enclosure serial number
|
|
could not be determined or there is no enclosure following this one."
|
|
::= { cpqRackCommonEnclosureEntry 25 }
|
|
|
|
|
|
cpqRackCommonEnclosureAddress OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The unique address of the enclosure within the rack.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 26 }
|
|
|
|
|
|
cpqRackCommonEnclosureProductId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The product id string of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
product id string."
|
|
::= { cpqRackCommonEnclosureEntry 27 }
|
|
|
|
|
|
cpqRackCommonEnclosureProductIdPrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The product id string of the enclosure immediately preceding or
|
|
above this enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
product id string."
|
|
::= { cpqRackCommonEnclosureEntry 28 }
|
|
|
|
|
|
cpqRackCommonEnclosureProductIdNext OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The product id string of the enclosure immediately following or
|
|
below this enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
product id string."
|
|
::= { cpqRackCommonEnclosureEntry 29 }
|
|
|
|
|
|
cpqRackCommonEnclosureUUID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The universal unique identifier string of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
UUID string."
|
|
::= { cpqRackCommonEnclosureEntry 30 }
|
|
|
|
|
|
cpqRackCommonEnclosureUUIDPrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The universal unique identifier string of the enclosure
|
|
immediately preceding or above this enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
UUID string or if there is no preceding enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 31 }
|
|
|
|
|
|
cpqRackCommonEnclosureUUIDNext OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The universal unique identifier string of the enclosure
|
|
immediately following or below this enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
UUID string or if there is no following enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 32 }
|
|
|
|
|
|
cpqRackCommonEnclosureHasManagers OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The enclosure contains managers.
|
|
|
|
This will be true(2) is the enclosure contains managers.
|
|
The cpqRackCommonEnclosureManagerTable will contain the manager
|
|
specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureManagerTable to get
|
|
complete information on the enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 33 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureTempEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack enclosure temperature sensor information."
|
|
::= { cpqRackCommonEnclosure 2 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureTempEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack enclosure temperature sensor description."
|
|
INDEX { cpqRackCommonEnclosureTempRack , cpqRackCommonEnclosureTempChassis, cpqRackCommonEnclosureTempSensorIndex }
|
|
|
|
::= { cpqRackCommonEnclosureTempTable 1 }
|
|
|
|
cpqRackCommonEnclosureTempEntry ::=
|
|
SEQUENCE {
|
|
cpqRackCommonEnclosureTempRack INTEGER,
|
|
cpqRackCommonEnclosureTempChassis INTEGER,
|
|
cpqRackCommonEnclosureTempSensorIndex INTEGER,
|
|
cpqRackCommonEnclosureTempSensorEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureTempLocation DisplayString,
|
|
cpqRackCommonEnclosureTempCurrent INTEGER,
|
|
cpqRackCommonEnclosureTempThreshold INTEGER,
|
|
cpqRackCommonEnclosureTempCondition INTEGER,
|
|
cpqRackCommonEnclosureTempType INTEGER,
|
|
cpqRackCommonEnclosureTempSensorEnclosureSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackCommonEnclosureTempRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureTempEntry 1 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureTempEntry 2 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this temperature sensor within
|
|
this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureTempEntry 3 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempSensorEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureTempEntry 4 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The location description of the temperature sensor within the
|
|
enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureTempEntry 5 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the current temperature sensor reading in degrees
|
|
celsius.
|
|
|
|
If this value cannot be determined by software, then a value
|
|
of -1 will be returned."
|
|
::= { cpqRackCommonEnclosureTempEntry 6 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the threshold temperature sensor setting
|
|
in degrees celsius. This is the temperature in which the
|
|
sensor will be considered to be in a tripped state this
|
|
causing some action to occur depending on the type of
|
|
the sensor. The action of temperature sensor threshold
|
|
will be indicated by the cpqRackCommonEnclosureTempType
|
|
item. If the type is blowout(5), then the temperature sensor
|
|
will cause the fans to speed up. If the type is caution(9),
|
|
then the temperature sensor is in a degraded state. If the
|
|
type is critical(15), then the enclosure will be considered
|
|
as in a failed state.
|
|
|
|
If this value cannot be determined by software, then a value
|
|
of -1 will be returned."
|
|
::= { cpqRackCommonEnclosureTempEntry 7 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Temperature sensor condition.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Temperature could not be determined.
|
|
|
|
ok(2)
|
|
The temperature sensor is within the normal operating range.
|
|
|
|
degraded(3)
|
|
The temperature sensor is outside of the normal operating range.
|
|
|
|
failed(4)
|
|
The temperature sensor detects a condition that could
|
|
possibly damage the system.
|
|
|
|
The system will automatically shutdown if the failed(4) condition
|
|
results, so it is unlikely that this value will ever be returned
|
|
by the agent."
|
|
::= { cpqRackCommonEnclosureTempEntry 8 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
blowout(5),
|
|
caution(9),
|
|
critical(15)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies the type of this instance of temperature
|
|
sensor.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Temperature threshold type could not be determined.
|
|
|
|
blowout(5)
|
|
If a blowout(5) temperature sensor reaches its threshold,
|
|
the fan or fans in the area of the temperature sensor will
|
|
increase in speed in an attempt to reduce the temperature
|
|
before a caution or critical threshold is reached.
|
|
|
|
caution(9)
|
|
If a caution(9) temperature sensor reaches its threshold, the
|
|
cpqRackCommonEnclosureTempCondition will be set to degraded(3)
|
|
and the system will either continue or shutdown depending
|
|
on the user preferences.
|
|
|
|
critical(15)
|
|
If a critical(15) temperature sensor reaches its threshold,
|
|
the cpqHeTemperatureCondition will be set to failed(4)
|
|
and the system will shutdown."
|
|
::= { cpqRackCommonEnclosureTempEntry 9 }
|
|
|
|
|
|
cpqRackCommonEnclosureTempSensorEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure containing this temperature
|
|
sensor.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackCommonEnclosureTempEntry 10 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFanEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack enclosure fan information."
|
|
::= { cpqRackCommonEnclosure 3 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureFanEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack enclosure fan description."
|
|
INDEX { cpqRackCommonEnclosureFanRack , cpqRackCommonEnclosureFanChassis, cpqRackCommonEnclosureFanIndex }
|
|
|
|
::= { cpqRackCommonEnclosureFanTable 1 }
|
|
|
|
cpqRackCommonEnclosureFanEntry ::=
|
|
SEQUENCE {
|
|
cpqRackCommonEnclosureFanRack INTEGER,
|
|
cpqRackCommonEnclosureFanChassis INTEGER,
|
|
cpqRackCommonEnclosureFanIndex INTEGER,
|
|
cpqRackCommonEnclosureFanEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureFanLocation DisplayString,
|
|
cpqRackCommonEnclosureFanPartNumber DisplayString,
|
|
cpqRackCommonEnclosureFanSparePartNumber DisplayString,
|
|
cpqRackCommonEnclosureFanPresent INTEGER,
|
|
cpqRackCommonEnclosureFanRedundant INTEGER,
|
|
cpqRackCommonEnclosureFanRedundantGroupId INTEGER,
|
|
cpqRackCommonEnclosureFanCondition INTEGER,
|
|
cpqRackCommonEnclosureFanEnclosureSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackCommonEnclosureFanRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureFanEntry 1 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureFanEntry 2 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this fan within this
|
|
enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureFanEntry 3 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 4 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The location description of the fan within the enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 5 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The part number of the enclosure fan.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 6 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The spare part number of the enclosure fan.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 7 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the fan described is present in the system."
|
|
::= { cpqRackCommonEnclosureFanEntry 8 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanRedundant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notRedundant(2),
|
|
redundant(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the fan is in a redundant configuration."
|
|
::= { cpqRackCommonEnclosureFanEntry 9 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanRedundantGroupId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies the group number for redundant fans within this
|
|
enclosure."
|
|
::= { cpqRackCommonEnclosureFanEntry 10 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The condition of the fan.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Fan status detection is not supported.
|
|
|
|
ok(2)
|
|
The fan is operating properly.
|
|
|
|
degraded(2)
|
|
A redundant fan is not operating properly.
|
|
|
|
failed(4)
|
|
A non-redundant fan is not operating properly."
|
|
::= { cpqRackCommonEnclosureFanEntry 11 }
|
|
|
|
|
|
cpqRackCommonEnclosureFanEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure containing the fan.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 12 }
|
|
|
|
|
|
cpqRackCommonEnclosureFuseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFuseEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack enclosure fuse information."
|
|
::= { cpqRackCommonEnclosure 4 }
|
|
|
|
|
|
cpqRackCommonEnclosureFuseEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureFuseEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack enclosure fuse description."
|
|
INDEX { cpqRackCommonEnclosureFuseRack , cpqRackCommonEnclosureFuseChassis, cpqRackCommonEnclosureFuseIndex }
|
|
|
|
::= { cpqRackCommonEnclosureFuseTable 1 }
|
|
|
|
cpqRackCommonEnclosureFuseEntry ::=
|
|
SEQUENCE {
|
|
cpqRackCommonEnclosureFuseRack INTEGER,
|
|
cpqRackCommonEnclosureFuseChassis INTEGER,
|
|
cpqRackCommonEnclosureFuseIndex INTEGER,
|
|
cpqRackCommonEnclosureFuseEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureFuseLocation DisplayString,
|
|
cpqRackCommonEnclosureFusePresent INTEGER,
|
|
cpqRackCommonEnclosureFuseCondition INTEGER
|
|
}
|
|
|
|
cpqRackCommonEnclosureFuseRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureFuseEntry 1 }
|
|
|
|
|
|
cpqRackCommonEnclosureFuseChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureFuseEntry 2 }
|
|
|
|
|
|
cpqRackCommonEnclosureFuseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies the fuse within this enclosure."
|
|
::= { cpqRackCommonEnclosureFuseEntry 3 }
|
|
|
|
|
|
cpqRackCommonEnclosureFuseEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureFuseEntry 4 }
|
|
|
|
|
|
cpqRackCommonEnclosureFuseLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The location description of the fuse within the enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFuseEntry 5 }
|
|
|
|
|
|
cpqRackCommonEnclosureFusePresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the fuse described is present in the system."
|
|
::= { cpqRackCommonEnclosureFuseEntry 6 }
|
|
|
|
|
|
cpqRackCommonEnclosureFuseCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The condition of the fuse.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Fuse status detection is not supported.
|
|
|
|
ok(2)
|
|
The fuse is operating properly.
|
|
|
|
failed(4)
|
|
A fuse has been tripped or is not operating properly."
|
|
::= { cpqRackCommonEnclosureFuseEntry 7 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFruEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack enclosure field replaceable units information."
|
|
::= { cpqRackCommonEnclosure 5 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureFruEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack enclosure field replaceable unit description."
|
|
INDEX { cpqRackCommonEnclosureFruRack , cpqRackCommonEnclosureFruChassis, cpqRackCommonEnclosureFruIndex }
|
|
|
|
::= { cpqRackCommonEnclosureFruTable 1 }
|
|
|
|
cpqRackCommonEnclosureFruEntry ::=
|
|
SEQUENCE {
|
|
cpqRackCommonEnclosureFruRack INTEGER,
|
|
cpqRackCommonEnclosureFruChassis INTEGER,
|
|
cpqRackCommonEnclosureFruIndex INTEGER,
|
|
cpqRackCommonEnclosureFruEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureFruDescription DisplayString,
|
|
cpqRackCommonEnclosureFruLocation DisplayString,
|
|
cpqRackCommonEnclosureFruAssemblyPartNumber DisplayString,
|
|
cpqRackCommonEnclosureFruSparePartNumber DisplayString,
|
|
cpqRackCommonEnclosureFruAutoRev DisplayString,
|
|
cpqRackCommonEnclosureFruSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackCommonEnclosureFruRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureFruEntry 1 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureFruEntry 2 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies the FRU within this enclosure."
|
|
::= { cpqRackCommonEnclosureFruEntry 3 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureFruEntry 4 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A description of the FRU component.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
description information."
|
|
::= { cpqRackCommonEnclosureFruEntry 5 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The location description of the FRU within the enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFruEntry 6 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruAssemblyPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The assembly part number of the FRU within the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
information."
|
|
::= { cpqRackCommonEnclosureFruEntry 7 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The spare part number of the FRU within the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
information."
|
|
::= { cpqRackCommonEnclosureFruEntry 8 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruAutoRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The auto revision number of the FRU within the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
information."
|
|
::= { cpqRackCommonEnclosureFruEntry 9 }
|
|
|
|
|
|
cpqRackCommonEnclosureFruSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the FRU within the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number."
|
|
::= { cpqRackCommonEnclosureFruEntry 10 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureManagerEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack enclosure manager information."
|
|
::= { cpqRackCommonEnclosure 6 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureManagerEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack enclosure manager description."
|
|
INDEX { cpqRackCommonEnclosureManagerRack , cpqRackCommonEnclosureManagerChassis, cpqRackCommonEnclosureManagerIndex }
|
|
|
|
::= { cpqRackCommonEnclosureManagerTable 1 }
|
|
|
|
cpqRackCommonEnclosureManagerEntry ::=
|
|
SEQUENCE {
|
|
cpqRackCommonEnclosureManagerRack INTEGER,
|
|
cpqRackCommonEnclosureManagerChassis INTEGER,
|
|
cpqRackCommonEnclosureManagerIndex INTEGER,
|
|
cpqRackCommonEnclosureManagerEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureManagerLocation DisplayString,
|
|
cpqRackCommonEnclosureManagerPartNumber DisplayString,
|
|
cpqRackCommonEnclosureManagerSparePartNumber DisplayString,
|
|
cpqRackCommonEnclosureManagerSerialNum DisplayString,
|
|
cpqRackCommonEnclosureManagerRole INTEGER,
|
|
cpqRackCommonEnclosureManagerPresent INTEGER,
|
|
cpqRackCommonEnclosureManagerRedundant INTEGER,
|
|
cpqRackCommonEnclosureManagerCondition INTEGER,
|
|
cpqRackCommonEnclosureManagerEnclosureSerialNum DisplayString,
|
|
cpqRackCommonEnclosureManagerUUID DisplayString,
|
|
cpqRackCommonEnclosureManagerFWRev DisplayString
|
|
}
|
|
|
|
cpqRackCommonEnclosureManagerRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureManagerEntry 1 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureManagerEntry 2 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this manager within this
|
|
enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureManagerEntry 3 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureManagerEntry 4 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The location description of the manager within the enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureManagerEntry 5 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The part number of the enclosure manager.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureManagerEntry 6 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The spare part number of the enclosure manager.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureManagerEntry 7 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure manager.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackCommonEnclosureManagerEntry 8 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby(1),
|
|
active(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies the current role of the manager."
|
|
::= { cpqRackCommonEnclosureManagerEntry 9 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the manager described is present in the system."
|
|
::= { cpqRackCommonEnclosureManagerEntry 10 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerRedundant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notRedundant(2),
|
|
redundant(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the manager is in a redundant configuration."
|
|
::= { cpqRackCommonEnclosureManagerEntry 11 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The condition of the manager.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Manager status detection is not supported.
|
|
|
|
ok(2)
|
|
The manager is operating properly.
|
|
|
|
degraded(2)
|
|
A redundant manager is not operating properly.
|
|
|
|
failed(4)
|
|
A non-redundant manager is not operating properly."
|
|
::= { cpqRackCommonEnclosureManagerEntry 12 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure containing the manager.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackCommonEnclosureManagerEntry 13 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerUUID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The universal unique identifier string of the manager.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
UUID string."
|
|
::= { cpqRackCommonEnclosureManagerEntry 14 }
|
|
|
|
|
|
cpqRackCommonEnclosureManagerFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware revision of the enclosure manager.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
firmware revision or does not contain firmware."
|
|
::= { cpqRackCommonEnclosureManagerEntry 15 }
|
|
|
|
|
|
cpqRackServerEnclosureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackServerEnclosureEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack enclosure information for servers."
|
|
::= { cpqRackServerEnclosure 1 }
|
|
|
|
|
|
cpqRackServerEnclosureEntry OBJECT-TYPE
|
|
SYNTAX CpqRackServerEnclosureEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A server enclosure description."
|
|
INDEX { cpqRackServerEnclosureRack , cpqRackServerEnclosureIndex }
|
|
|
|
::= { cpqRackServerEnclosureTable 1 }
|
|
|
|
cpqRackServerEnclosureEntry ::=
|
|
SEQUENCE {
|
|
cpqRackServerEnclosureRack INTEGER,
|
|
cpqRackServerEnclosureIndex INTEGER,
|
|
cpqRackServerEnclosureName DisplayString,
|
|
cpqRackServerEnclosureMaxNumBlades INTEGER,
|
|
cpqRackServerEnclosureMaxNumBladesX INTEGER,
|
|
cpqRackServerEnclosureMaxNumBladesY INTEGER
|
|
}
|
|
|
|
cpqRackServerEnclosureRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackServerEnclosureEntry 1 }
|
|
|
|
|
|
cpqRackServerEnclosureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this server enclosure in the rack."
|
|
::= { cpqRackServerEnclosureEntry 2 }
|
|
|
|
|
|
cpqRackServerEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the server enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackServerEnclosureEntry 3 }
|
|
|
|
|
|
cpqRackServerEnclosureMaxNumBlades OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The maximum number of server blades the enclosure can contain.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackServerEnclosureEntry 4 }
|
|
|
|
|
|
cpqRackServerEnclosureMaxNumBladesX OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The maximum number of server blades in x-direction (from left to right)
|
|
the enclosure can contain."
|
|
::= { cpqRackServerEnclosureEntry 5 }
|
|
|
|
|
|
cpqRackServerEnclosureMaxNumBladesY OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The maximum number of server blades in y-direction (from top to bottom)
|
|
the enclosure can contain."
|
|
::= { cpqRackServerEnclosureEntry 6 }
|
|
|
|
|
|
cpqRackPowerEnclosureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackPowerEnclosureEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack power enclosure information."
|
|
::= { cpqRackPowerEnclosure 1 }
|
|
|
|
|
|
cpqRackPowerEnclosureEntry OBJECT-TYPE
|
|
SYNTAX CpqRackPowerEnclosureEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack power enclosure description."
|
|
INDEX { cpqRackPowerEnclosureRack , cpqRackPowerEnclosureIndex }
|
|
|
|
::= { cpqRackPowerEnclosureTable 1 }
|
|
|
|
cpqRackPowerEnclosureEntry ::=
|
|
SEQUENCE {
|
|
cpqRackPowerEnclosureRack INTEGER,
|
|
cpqRackPowerEnclosureIndex INTEGER,
|
|
cpqRackPowerEnclosureName DisplayString,
|
|
cpqRackPowerEnclosureMgmtBoardSerialNum DisplayString,
|
|
cpqRackPowerEnclosureRedundant INTEGER,
|
|
cpqRackPowerEnclosureLoadBalanced INTEGER,
|
|
cpqRackPowerEnclosureInputPwrType INTEGER,
|
|
cpqRackPowerEnclosurePwrFeedMax INTEGER,
|
|
cpqRackPowerEnclosureCondition INTEGER,
|
|
cpqRackPowerEnclosureBladeAutopoweron INTEGER
|
|
}
|
|
|
|
cpqRackPowerEnclosureRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackPowerEnclosureEntry 1 }
|
|
|
|
|
|
cpqRackPowerEnclosureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this power enclosure in the rack."
|
|
::= { cpqRackPowerEnclosureEntry 2 }
|
|
|
|
|
|
cpqRackPowerEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the power enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackPowerEnclosureEntry 3 }
|
|
|
|
|
|
cpqRackPowerEnclosureMgmtBoardSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number."
|
|
::= { cpqRackPowerEnclosureEntry 4 }
|
|
|
|
|
|
cpqRackPowerEnclosureRedundant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notRedundant(2),
|
|
redundant(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This indicates if the power supply enclosure is in a redundant
|
|
state."
|
|
::= { cpqRackPowerEnclosureEntry 5 }
|
|
|
|
|
|
cpqRackPowerEnclosureLoadBalanced OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notLoadBalanced(2),
|
|
loadBalanced(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This indicates if the power supply enclosure is in a load
|
|
balanced state."
|
|
::= { cpqRackPowerEnclosureEntry 6 }
|
|
|
|
|
|
cpqRackPowerEnclosureInputPwrType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
singlePhase(2),
|
|
threePhase(3),
|
|
directCurrent(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This indicates type of input facility power."
|
|
::= { cpqRackPowerEnclosureEntry 7 }
|
|
|
|
|
|
cpqRackPowerEnclosurePwrFeedMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the maximum facility power in watts.
|
|
|
|
The maximum facility power being fed to this power enclosure.
|
|
|
|
The value will be -1 if the power enclosure does not report the
|
|
value or if the value is not known."
|
|
::= { cpqRackPowerEnclosureEntry 8 }
|
|
|
|
|
|
cpqRackPowerEnclosureCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This indicates current condition of the power enclosure.
|
|
|
|
other(1)
|
|
The power enclosure condition could not be determined.
|
|
|
|
ok(2)
|
|
The power enclosure is operating normally.
|
|
|
|
degraded(3)
|
|
The power enclosure is in a degraded state. The power subsystem
|
|
may not be load balanced or may have lost redundancy."
|
|
::= { cpqRackPowerEnclosureEntry 9 }
|
|
|
|
|
|
cpqRackPowerEnclosureBladeAutopoweron OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
enabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "This indicates current condition of the power enclosure.
|
|
|
|
other(1)
|
|
The blade auto power on feature could not be determined.
|
|
|
|
disabled(2)
|
|
The enclosure will not automatically power on a blade when inserted.
|
|
|
|
enabled(3)
|
|
The enclosure will automatically power on a blade when inserted."
|
|
::= { cpqRackPowerEnclosureEntry 10 }
|
|
|
|
|
|
cpqRackLastEAEEvent OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..512))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Data for the last EAE event."
|
|
::= { cpqRackServerEnclosure 2 }
|
|
|
|
|
|
cpqRackServerBladeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackServerBladeEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack server blade information."
|
|
::= { cpqRackServerBlade 1 }
|
|
|
|
|
|
cpqRackServerBladeEntry OBJECT-TYPE
|
|
SYNTAX CpqRackServerBladeEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack server blade description."
|
|
INDEX { cpqRackServerBladeRack , cpqRackServerBladeChassis, cpqRackServerBladeIndex }
|
|
|
|
::= { cpqRackServerBladeTable 1 }
|
|
|
|
cpqRackServerBladeEntry ::=
|
|
SEQUENCE {
|
|
cpqRackServerBladeRack INTEGER,
|
|
cpqRackServerBladeChassis INTEGER,
|
|
cpqRackServerBladeIndex INTEGER,
|
|
cpqRackServerBladeName DisplayString,
|
|
cpqRackServerBladeEnclosureName DisplayString,
|
|
cpqRackServerBladePartNumber DisplayString,
|
|
cpqRackServerBladeSparePartNumber DisplayString,
|
|
cpqRackServerBladePosition INTEGER,
|
|
cpqRackServerBladeHeight INTEGER,
|
|
cpqRackServerBladeWidth INTEGER,
|
|
cpqRackServerBladeDepth INTEGER,
|
|
cpqRackServerBladePresent INTEGER,
|
|
cpqRackServerBladeHasFuses INTEGER,
|
|
cpqRackServerBladeEnclosureSerialNum DisplayString,
|
|
cpqRackServerBladeSlotsUsed INTEGER,
|
|
cpqRackServerBladeSerialNum DisplayString,
|
|
cpqRackServerBladeProductId DisplayString,
|
|
cpqRackServerBladeUid DisplayString,
|
|
cpqRackServerBladeSlotsUsedX INTEGER,
|
|
cpqRackServerBladeSlotsUsedY INTEGER,
|
|
cpqRackServerBladeStatus INTEGER,
|
|
cpqRackServerBladeFaultMajor INTEGER,
|
|
cpqRackServerBladeFaultMinor INTEGER,
|
|
cpqRackServerBladeFaultDiagnosticString DisplayString,
|
|
cpqRackServerBladePowered INTEGER,
|
|
cpqRackServerBladeUIDState INTEGER,
|
|
cpqRackServerBladeSystemBIOSRevision DisplayString,
|
|
cpqRackServerBladeSystemBIOSFlashingStatus INTEGER,
|
|
cpqRackServerBladeHasManagementDevice INTEGER,
|
|
cpqRackServerBladeManagementDeviceFirmwareRevision DisplayString,
|
|
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus INTEGER,
|
|
cpqRackServerBladeDiagnosticAdaptorPresence INTEGER,
|
|
cpqRackServerBladeASREnabled INTEGER,
|
|
cpqRackServerBladeFrontIOBlankingModeStatus INTEGER,
|
|
cpqRackServerBladePOSTStatus INTEGER,
|
|
cpqRackServerBladePXEBootModeStatus INTEGER,
|
|
cpqRackServerBladePendingBootOrderChange INTEGER,
|
|
cpqRackServerBladeWattageMax INTEGER,
|
|
cpqRackServerBladeWattageAvg INTEGER,
|
|
cpqRackServerBladeWattageMin INTEGER
|
|
}
|
|
|
|
cpqRackServerBladeRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackServerBladeEntry 1 }
|
|
|
|
|
|
cpqRackServerBladeChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackServerBladeEntry 2 }
|
|
|
|
|
|
cpqRackServerBladeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this server blade within the enclosure."
|
|
::= { cpqRackServerBladeEntry 3 }
|
|
|
|
|
|
cpqRackServerBladeName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the server blade.
|
|
|
|
The string will be empty if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 4 }
|
|
|
|
|
|
cpqRackServerBladeEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the enclosure which contains the blade.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackServerBladeEntry 5 }
|
|
|
|
|
|
cpqRackServerBladePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The part number of the server blade.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackServerBladeEntry 6 }
|
|
|
|
|
|
cpqRackServerBladeSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The spare part number of the server blade.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackServerBladeEntry 7 }
|
|
|
|
|
|
cpqRackServerBladePosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The position or slot number of the server blade within the
|
|
server enclosure.
|
|
|
|
This will be -1 if the server enclosure does not report the
|
|
information or it could not be determined."
|
|
::= { cpqRackServerBladeEntry 8 }
|
|
|
|
|
|
cpqRackServerBladeHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The height dimension of the rack space taken by the server
|
|
blade expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 9 }
|
|
|
|
|
|
cpqRackServerBladeWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The width dimension of the rack space taken by the server
|
|
blade expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 10 }
|
|
|
|
|
|
cpqRackServerBladeDepth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The depth dimension of the rack space taken by the server
|
|
blade expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 11 }
|
|
|
|
|
|
cpqRackServerBladePresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the server blade described is present in the
|
|
enclosure."
|
|
::= { cpqRackServerBladeEntry 12 }
|
|
|
|
|
|
cpqRackServerBladeHasFuses OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The server blade contains fuses.
|
|
|
|
This will be true(2) is the server blade contains fuses.
|
|
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
|
specific information.
|
|
|
|
Match the cpqRackServerBladeEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureFanTable to get complete
|
|
information on the fuses."
|
|
::= { cpqRackServerBladeEntry 13 }
|
|
|
|
|
|
cpqRackServerBladeEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure which contains the blade.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackServerBladeEntry 14 }
|
|
|
|
|
|
cpqRackServerBladeSlotsUsed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of slot positions occupied by this server blade. This
|
|
is used to indicate a server blade which may obscure an adjacent
|
|
blade slot.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 15 }
|
|
|
|
|
|
cpqRackServerBladeSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the server blade.
|
|
|
|
The string will be empty if the system does not report the
|
|
serial number function."
|
|
::= { cpqRackServerBladeEntry 16 }
|
|
|
|
|
|
cpqRackServerBladeProductId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The product id string of the server blade.
|
|
|
|
The string will be empty if the system does not report the
|
|
product id function."
|
|
::= { cpqRackServerBladeEntry 17 }
|
|
|
|
|
|
cpqRackServerBladeUid OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The server blade unique identifier (UUID).
|
|
|
|
The string will be empty if the blade does not report the
|
|
UUID or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 18 }
|
|
|
|
|
|
cpqRackServerBladeSlotsUsedX OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of slot positions in x-direction (from left to right)
|
|
occupied by this server blade. This is used to indicate a server blade
|
|
which may obscure an adjacent blade slot.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 19 }
|
|
|
|
|
|
cpqRackServerBladeSlotsUsedY OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of slot positions in y-direction (from top to bottom)
|
|
occupied by this server blade. This is used to indicate a server blade
|
|
which may obscure an adjacent blade slot.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 20 }
|
|
|
|
|
|
cpqRackServerBladeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The health status of the blade.
|
|
|
|
This will be other(1) if the rack does not report the information
|
|
or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 21 }
|
|
|
|
|
|
cpqRackServerBladeFaultMajor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The major fault code of the blade fault
|
|
reported by the enclosure manager.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 22 }
|
|
|
|
|
|
cpqRackServerBladeFaultMinor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The minor fault code of the blade fault
|
|
reported by the enclosure manager.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 23 }
|
|
|
|
|
|
cpqRackServerBladeFaultDiagnosticString OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The server blade fault diagnostic string. This will contain a probable
|
|
cause and potential diagnostic action to be taken to remedy the fault condition.
|
|
|
|
The string will be empty if the blade does not report the
|
|
diagnostic string or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 24 }
|
|
|
|
|
|
cpqRackServerBladePowered OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
on(2),
|
|
off(3),
|
|
powerStagedOff(4),
|
|
reboot(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The power state of the blade.
|
|
|
|
This will be other(1) if the rack does not report the information or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 25 }
|
|
|
|
|
|
cpqRackServerBladeUIDState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
ledOn(3),
|
|
ledOff(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The Unit Identifier LED.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
The state of the LED could not be determined. Setting the
|
|
LED state is not allowed.
|
|
|
|
none(2)
|
|
The LED is not present. Setting LED state is not allowed.
|
|
|
|
ledOn(3)
|
|
The LED is present and ON. The LED can be turned off
|
|
by setting the cpqRackServerBladeUIDState to ledOff(4).
|
|
|
|
ledOff(4)
|
|
The LED is present and OFF. The LED can be turned on
|
|
by setting the cpqRackServerBladeUIDState to ledOn(3).
|
|
"
|
|
::= { cpqRackServerBladeEntry 26 }
|
|
|
|
|
|
cpqRackServerBladeSystemBIOSRevision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The server blade system bios revision.
|
|
|
|
The string will be empty if the blade does not report the
|
|
system bios revision or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 27 }
|
|
|
|
|
|
cpqRackServerBladeSystemBIOSFlashingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
normal(2),
|
|
flashing(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Blade server system BIOS flashing / flash mode status indication.
|
|
|
|
This will be other(1) if the rack does not report the information or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 28 }
|
|
|
|
|
|
cpqRackServerBladeHasManagementDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The blade server contains one or more management devices.
|
|
|
|
This will be true(2) if the blade server contains managers and false (1) if not
|
|
or if it can't be detected."
|
|
::= { cpqRackServerBladeEntry 29 }
|
|
|
|
|
|
cpqRackServerBladeManagementDeviceFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The server blade management device firwmware revision.
|
|
|
|
The string will be empty if the blade does not report the
|
|
management device firwmware revision or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 30 }
|
|
|
|
|
|
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
normal(2),
|
|
flashing(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Blade server management device firwmware flashing / flash mode status indication.
|
|
|
|
This will be other(1) if the rack does not report this information or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 31 }
|
|
|
|
|
|
cpqRackServerBladeDiagnosticAdaptorPresence OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "This specifies if a blade diagnostic adaptor is currently plugged into the system."
|
|
::= { cpqRackServerBladeEntry 32 }
|
|
|
|
|
|
cpqRackServerBladeASREnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the target blade server has Automatic Service Recovery feature enabled.
|
|
|
|
This will be true(2) if the blade server has this feature eanbled and false (1) if not
|
|
or if it can't be detected."
|
|
::= { cpqRackServerBladeEntry 33 }
|
|
|
|
|
|
cpqRackServerBladeFrontIOBlankingModeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
inactive(2),
|
|
active(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the target blade server has the front IO ports blanking feature enabled.
|
|
|
|
This will be Active(3) if the blade server has this feature eanbled, Inactive (2) if not,
|
|
or Unknown(1) if it can't be determined."
|
|
::= { cpqRackServerBladeEntry 34 }
|
|
|
|
|
|
cpqRackServerBladePOSTStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
started(2),
|
|
completed(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Blade server power-on self test (POST) status.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
The state of the blade POST could not be determined.
|
|
|
|
started(2)
|
|
Blade has started Power-on-self-test (POST) process.
|
|
|
|
completed(3)
|
|
Blade has finished Power-on-self-test (POST) process.
|
|
|
|
failed(4)
|
|
Blade has failed to complete Power-on-self-test (POST) process and halted.
|
|
|
|
This will be other(1) if the rack does not report this information or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 35 }
|
|
|
|
|
|
cpqRackServerBladePXEBootModeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
inactive(2),
|
|
active(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the target blade server is in PXE boot mode.
|
|
|
|
This will be Active(3) if the blade server has this feature enbled, Inactive (2) if not,
|
|
or Unknown(1) if it can't be determined."
|
|
::= { cpqRackServerBladeEntry 36 }
|
|
|
|
|
|
cpqRackServerBladePendingBootOrderChange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
firstPXE(3),
|
|
firstHDD(4),
|
|
firstRBSU(5),
|
|
oncePXE(6),
|
|
onceHDD(7),
|
|
onceRBSU(8),
|
|
alwaysPXE(9),
|
|
alwaysHDD(10),
|
|
alwaysRBSU(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Blade server pending boot order setting change state.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1) - Unknown or cannot be determined
|
|
none(2) - No Changes
|
|
firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First
|
|
firstHDD(4) - First Boot To Local HD
|
|
firstRBSU(5) - First Boot To ROM Based Setup Utility
|
|
oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once
|
|
onceHDD(7) - Boot To Local HD Once
|
|
onceRBSU(8) - Boot To ROM Based Setup Utility Once
|
|
alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE)
|
|
alwaysHDD(10) - Always Boot To Local HD
|
|
alwaysRBSU(11) - Always Boot To ROM Based Setup Utility
|
|
|
|
This will be other(1) if the rack does not report this information or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 37 }
|
|
|
|
|
|
cpqRackServerBladeWattageMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Maximum wattage the server has consumed during this power cycle."
|
|
::= { cpqRackServerBladeEntry 38 }
|
|
|
|
|
|
cpqRackServerBladeWattageAvg OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Average wattage the server is consuming, averaged over a period defined by the product."
|
|
::= { cpqRackServerBladeEntry 39 }
|
|
|
|
|
|
cpqRackServerBladeWattageMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Minimum wattage the server has consumed, computed from a period defined by the product. Value
|
|
will be 0 if not supported, but other wattage values are supported."
|
|
::= { cpqRackServerBladeEntry 40 }
|
|
|
|
|
|
cpqRackServerNetworkingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackServerNetworkingEntry
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A table of rack server networking information."
|
|
::= { cpqRackServerNetworking 1 }
|
|
|
|
|
|
cpqRackServerNetworkingEntry OBJECT-TYPE
|
|
SYNTAX CpqRackServerNetworkingEntry
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A rack server networking description."
|
|
INDEX { cpqRackServerNetworkingRack , cpqRackServerNetworkingChassis, cpqRackServerNetworkingIndex }
|
|
|
|
::= { cpqRackServerNetworkingTable 1 }
|
|
|
|
cpqRackServerNetworkingEntry ::=
|
|
SEQUENCE {
|
|
cpqRackServerNetworkingRack INTEGER,
|
|
cpqRackServerNetworkingChassis INTEGER,
|
|
cpqRackServerNetworkingIndex INTEGER,
|
|
cpqRackServerNetworkingName DisplayString,
|
|
cpqRackServerNetworkingEnclosureName DisplayString,
|
|
cpqRackServerNetworkingEthernetInterfaces INTEGER,
|
|
cpqRackServerNetworkingEthernetMACAddress DisplayString
|
|
}
|
|
|
|
cpqRackServerNetworkingRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackServerNetworkingEntry 1 }
|
|
|
|
|
|
cpqRackServerNetworkingChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackServerNetworkingEntry 2 }
|
|
|
|
|
|
cpqRackServerNetworkingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A number that uniquely specifies this server within the enclosure."
|
|
::= { cpqRackServerNetworkingEntry 3 }
|
|
|
|
|
|
cpqRackServerNetworkingName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The name of the server.
|
|
|
|
The string will be empty if it could not be determined."
|
|
::= { cpqRackServerNetworkingEntry 4 }
|
|
|
|
|
|
cpqRackServerNetworkingEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The name of the enclosure which contains the server.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or if it could not be determined."
|
|
::= { cpqRackServerNetworkingEntry 5 }
|
|
|
|
|
|
cpqRackServerNetworkingEthernetInterfaces OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A number that specifies the amount of
|
|
Ethernet network interfaces in the server."
|
|
::= { cpqRackServerNetworkingEntry 6 }
|
|
|
|
|
|
cpqRackServerNetworkingEthernetMACAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The MAC address for the Ethernet NIC populated in the server.
|
|
|
|
The string will be empty if it could not be determined."
|
|
::= { cpqRackServerNetworkingEntry 7 }
|
|
|
|
|
|
cpqRackServerTempSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackServerTempSensorEntry
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A table of rack server temperature sensor information."
|
|
::= { cpqRackServerTempSensor 1 }
|
|
|
|
|
|
cpqRackServerTempSensorEntry OBJECT-TYPE
|
|
SYNTAX CpqRackServerTempSensorEntry
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A rack server temperature sensor description."
|
|
INDEX { cpqRackServerTempSensorRack , cpqRackServerTempSensorChassis, cpqRackServerTempSensorIndex }
|
|
|
|
::= { cpqRackServerTempSensorTable 1 }
|
|
|
|
cpqRackServerTempSensorEntry ::=
|
|
SEQUENCE {
|
|
cpqRackServerTempSensorRack INTEGER,
|
|
cpqRackServerTempSensorChassis INTEGER,
|
|
cpqRackServerTempSensorIndex INTEGER,
|
|
cpqRackServerTempSensorName DisplayString,
|
|
cpqRackServerTempSensorEnclosureName DisplayString,
|
|
cpqRackServerTempSensorCount INTEGER,
|
|
cpqRackServerTempSensorLocation DisplayString,
|
|
cpqRackServerTempSensorCurrent INTEGER,
|
|
cpqRackServerTempSensorThreshold INTEGER,
|
|
cpqRackServerTempSensorCondition INTEGER,
|
|
cpqRackServerTempSensorType INTEGER
|
|
}
|
|
|
|
cpqRackServerTempSensorRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackServerTempSensorEntry 1 }
|
|
|
|
|
|
cpqRackServerTempSensorChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackServerTempSensorEntry 2 }
|
|
|
|
|
|
cpqRackServerTempSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A number that uniquely specifies this server within the enclosure."
|
|
::= { cpqRackServerTempSensorEntry 3 }
|
|
|
|
|
|
cpqRackServerTempSensorName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The name of the server.
|
|
|
|
The string will be empty if it could not be determined."
|
|
::= { cpqRackServerTempSensorEntry 4 }
|
|
|
|
|
|
cpqRackServerTempSensorEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The name of the enclosure which contains the server.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or if it could not be determined."
|
|
::= { cpqRackServerTempSensorEntry 5 }
|
|
|
|
|
|
cpqRackServerTempSensorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "A number that specifies the amount of
|
|
temperature sensors in the server."
|
|
::= { cpqRackServerTempSensorEntry 6 }
|
|
|
|
|
|
cpqRackServerTempSensorLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The location description of the temperature sensor within the
|
|
blade server.
|
|
|
|
The string will be empty if it could not be determined."
|
|
::= { cpqRackServerTempSensorEntry 7 }
|
|
|
|
|
|
cpqRackServerTempSensorCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "This is the current temperature sensor reading in degrees
|
|
celsius.
|
|
|
|
If this value cannot be determined by software, then a value
|
|
of -1 will be returned."
|
|
::= { cpqRackServerTempSensorEntry 8 }
|
|
|
|
|
|
cpqRackServerTempSensorThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "This is the threshold temperature sensor setting
|
|
in degrees celsius. This is the temperature in which the
|
|
sensor will be considered to be in a tripped state this
|
|
causing some action to occur depending on the type of
|
|
the sensor. The action of temperature sensor threshold
|
|
will be indicated by the cpqRackServerTempSensorType
|
|
item. If the type is blowout(5), then the temperature sensor
|
|
will cause the fans to speed up. If the type is caution(9),
|
|
then the temperature sensor is in a degraded state. If the
|
|
type is critical(15), then the enclosure will be considered
|
|
as in a failed state.
|
|
|
|
If this value cannot be determined by software, then a value
|
|
of -1 will be returned."
|
|
::= { cpqRackServerTempSensorEntry 9 }
|
|
|
|
|
|
cpqRackServerTempSensorCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The Temperature sensor condition.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Temperature could not be determined.
|
|
|
|
ok(2)
|
|
The temperature sensor is within the normal operating range.
|
|
|
|
degraded(3)
|
|
The temperature sensor is outside of the normal operating range.
|
|
|
|
failed(4)
|
|
The temperature sensor detects a condition that could
|
|
possibly overheat the system.
|
|
|
|
The system will automatically shutdown if the failed(4) condition
|
|
results, so it is unlikely that this value will ever be returned
|
|
by the agent."
|
|
::= { cpqRackServerTempSensorEntry 10 }
|
|
|
|
|
|
cpqRackServerTempSensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
blowout(5),
|
|
caution(9),
|
|
critical(15)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "This specifies the type of this instance of temperature
|
|
sensor.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Temperature threshold type could not be determined.
|
|
|
|
blowout(5)
|
|
If a blowout(5) temperature sensor reaches its threshold,
|
|
the fan or fans in the area of the temperature sensor will
|
|
increase in speed in an attempt to reduce the temperature
|
|
before a caution or critical threshold is reached.
|
|
|
|
caution(9)
|
|
If a caution(9) temperature sensor reaches its threshold, the
|
|
cpqRackServerTempSensorCondition will be set to degraded(3)
|
|
and the system will either continue or shutdown depending
|
|
on the local blade server policy settings.
|
|
|
|
critical(15)
|
|
If a critical(15) temperature sensor reaches its threshold,
|
|
cpqRackServerTempSensorCondition will be set to failed(4)
|
|
and the blade server will shutdown."
|
|
::= { cpqRackServerTempSensorEntry 11 }
|
|
|
|
|
|
cpqRackPowerSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackPowerSupplyEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack power supply information."
|
|
::= { cpqRackPowerSupply 1 }
|
|
|
|
|
|
cpqRackPowerSupplyEntry OBJECT-TYPE
|
|
SYNTAX CpqRackPowerSupplyEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack power supply description."
|
|
INDEX { cpqRackPowerSupplyRack , cpqRackPowerSupplyChassis, cpqRackPowerSupplyIndex }
|
|
|
|
::= { cpqRackPowerSupplyTable 1 }
|
|
|
|
cpqRackPowerSupplyEntry ::=
|
|
SEQUENCE {
|
|
cpqRackPowerSupplyRack INTEGER,
|
|
cpqRackPowerSupplyChassis INTEGER,
|
|
cpqRackPowerSupplyIndex INTEGER,
|
|
cpqRackPowerSupplyEnclosureName DisplayString,
|
|
cpqRackPowerSupplySerialNum DisplayString,
|
|
cpqRackPowerSupplyPartNumber DisplayString,
|
|
cpqRackPowerSupplySparePartNumber DisplayString,
|
|
cpqRackPowerSupplyFWRev DisplayString,
|
|
cpqRackPowerSupplyMaxPwrOutput INTEGER,
|
|
cpqRackPowerSupplyCurPwrOutput INTEGER,
|
|
cpqRackPowerSupplyPosition INTEGER,
|
|
cpqRackPowerSupplyIntakeTemp INTEGER,
|
|
cpqRackPowerSupplyExhaustTemp INTEGER,
|
|
cpqRackPowerSupplyStatus INTEGER,
|
|
cpqRackPowerSupplyInputLineStatus INTEGER,
|
|
cpqRackPowerSupplyPresent INTEGER,
|
|
cpqRackPowerSupplyCondition INTEGER,
|
|
cpqRackPowerSupplyEnclosureSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackPowerSupplyRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackPowerSupplyEntry 1 }
|
|
|
|
|
|
cpqRackPowerSupplyChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this power enclosure in the rack."
|
|
::= { cpqRackPowerSupplyEntry 2 }
|
|
|
|
|
|
cpqRackPowerSupplyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this power supply in the enclosure."
|
|
::= { cpqRackPowerSupplyEntry 3 }
|
|
|
|
|
|
cpqRackPowerSupplyEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the power supply enclosure in which this power supply
|
|
resides.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackPowerSupplyEntry 4 }
|
|
|
|
|
|
cpqRackPowerSupplySerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the power supply.
|
|
|
|
The string will be empty if the power supply does not report the
|
|
serial number."
|
|
::= { cpqRackPowerSupplyEntry 5 }
|
|
|
|
|
|
cpqRackPowerSupplyPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The part number of the power supply.
|
|
|
|
The string will be empty if the power supply does not report this
|
|
function."
|
|
::= { cpqRackPowerSupplyEntry 6 }
|
|
|
|
|
|
cpqRackPowerSupplySparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The spare part number of the power supply.
|
|
|
|
The string will be empty if the power supply does not report this
|
|
function."
|
|
::= { cpqRackPowerSupplyEntry 7 }
|
|
|
|
|
|
cpqRackPowerSupplyFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware revision of the power supply.
|
|
|
|
The string will be empty if the power supply does not report the
|
|
firmware revision."
|
|
::= { cpqRackPowerSupplyEntry 8 }
|
|
|
|
|
|
cpqRackPowerSupplyMaxPwrOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The maximum power output of the power supply in watts.
|
|
|
|
The value will be -1 if the power supply does not report the
|
|
value."
|
|
::= { cpqRackPowerSupplyEntry 9 }
|
|
|
|
|
|
cpqRackPowerSupplyCurPwrOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The current power output of the power supply in watts.
|
|
|
|
The value will be -1 if the power supply does not report the
|
|
value."
|
|
::= { cpqRackPowerSupplyEntry 10 }
|
|
|
|
|
|
cpqRackPowerSupplyPosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The position of the power supply within the power enclosure.
|
|
|
|
This will be -1 if the power enclosure does not report the
|
|
power supply information or it could not be determined."
|
|
::= { cpqRackPowerSupplyEntry 11 }
|
|
|
|
|
|
cpqRackPowerSupplyIntakeTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The current air temperature at the intake of the power supply
|
|
in degrees celsius.
|
|
|
|
The value will be -1 if the power supply does not report the
|
|
value."
|
|
::= { cpqRackPowerSupplyEntry 12 }
|
|
|
|
|
|
cpqRackPowerSupplyExhaustTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The current air temperature at the exhaust of the power supply
|
|
in degrees celsius.
|
|
|
|
The value will be -1 if the power supply does not report the
|
|
value."
|
|
::= { cpqRackPowerSupplyEntry 13 }
|
|
|
|
|
|
cpqRackPowerSupplyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(1),
|
|
generalFailure(2),
|
|
bistFailure(3),
|
|
fanFailure(4),
|
|
tempFailure(5),
|
|
interlockOpen(6),
|
|
epromFailed(7),
|
|
vrefFailed(8),
|
|
dacFailed(9),
|
|
ramTestFailed(10),
|
|
voltageChannelFailed(11),
|
|
orringdiodeFailed(12),
|
|
brownOut(13),
|
|
giveupOnStartup(14),
|
|
nvramInvalid(15),
|
|
calibrationTableInvalid(16)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of the power supply."
|
|
::= { cpqRackPowerSupplyEntry 14 }
|
|
|
|
|
|
cpqRackPowerSupplyInputLineStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(1),
|
|
lineOverVoltage(2),
|
|
lineUnderVoltage(3),
|
|
lineHit(4),
|
|
brownOut(5),
|
|
linePowerLoss(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of line input power."
|
|
::= { cpqRackPowerSupplyEntry 15 }
|
|
|
|
|
|
cpqRackPowerSupplyPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the power supply described is present in the
|
|
enclosure."
|
|
::= { cpqRackPowerSupplyEntry 16 }
|
|
|
|
|
|
cpqRackPowerSupplyCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The condition of the power supply.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
The status could not be determined or not present.
|
|
|
|
ok(2)
|
|
The power supply is operating normally.
|
|
|
|
degraded(3)
|
|
A temperature sensor, fan or other power supply component is
|
|
outside of normal operating range.
|
|
|
|
failed(4)
|
|
A power supply component detects a condition that could
|
|
possibly damage the system."
|
|
::= { cpqRackPowerSupplyEntry 17 }
|
|
|
|
|
|
cpqRackPowerSupplyEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the power supply enclosure in which this
|
|
power supply resides.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackPowerSupplyEntry 18 }
|
|
|
|
|
|
cpqRackNetConnectorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackNetConnectorEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of rack network connector information."
|
|
::= { cpqRackNetConnector 1 }
|
|
|
|
|
|
cpqRackNetConnectorEntry OBJECT-TYPE
|
|
SYNTAX CpqRackNetConnectorEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A rack network connector description."
|
|
INDEX { cpqRackNetConnectorRack , cpqRackNetConnectorChassis, cpqRackNetConnectorIndex }
|
|
|
|
::= { cpqRackNetConnectorTable 1 }
|
|
|
|
cpqRackNetConnectorEntry ::=
|
|
SEQUENCE {
|
|
cpqRackNetConnectorRack INTEGER,
|
|
cpqRackNetConnectorChassis INTEGER,
|
|
cpqRackNetConnectorIndex INTEGER,
|
|
cpqRackNetConnectorEnclosureName DisplayString,
|
|
cpqRackNetConnectorName DisplayString,
|
|
cpqRackNetConnectorModel DisplayString,
|
|
cpqRackNetConnectorSerialNum DisplayString,
|
|
cpqRackNetConnectorPartNumber DisplayString,
|
|
cpqRackNetConnectorSparePartNumber DisplayString,
|
|
cpqRackNetConnectorFWRev DisplayString,
|
|
cpqRackNetConnectorType INTEGER,
|
|
cpqRackNetConnectorLocation DisplayString,
|
|
cpqRackNetConnectorPresent INTEGER,
|
|
cpqRackNetConnectorHasFuses INTEGER,
|
|
cpqRackNetConnectorEnclosureSerialNum DisplayString,
|
|
cpqRackNetConnectorTechnologyType INTEGER,
|
|
cpqRackNetConnectorDeviceType INTEGER
|
|
}
|
|
|
|
cpqRackNetConnectorRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this rack."
|
|
::= { cpqRackNetConnectorEntry 1 }
|
|
|
|
|
|
cpqRackNetConnectorChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this server enclosure in the rack."
|
|
::= { cpqRackNetConnectorEntry 2 }
|
|
|
|
|
|
cpqRackNetConnectorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number that uniquely specifies this network connector in the rack."
|
|
::= { cpqRackNetConnectorEntry 3 }
|
|
|
|
|
|
cpqRackNetConnectorEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the network connector enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackNetConnectorEntry 4 }
|
|
|
|
|
|
cpqRackNetConnectorName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the network connector.
|
|
|
|
The string will be empty if the network connector does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackNetConnectorEntry 5 }
|
|
|
|
|
|
cpqRackNetConnectorModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The model name of the network connector.
|
|
|
|
The string will be empty if the network connector does not report the
|
|
model information."
|
|
::= { cpqRackNetConnectorEntry 6 }
|
|
|
|
|
|
cpqRackNetConnectorSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the network connector.
|
|
|
|
The string will be empty if the network connector does not report the
|
|
serial number."
|
|
::= { cpqRackNetConnectorEntry 7 }
|
|
|
|
|
|
cpqRackNetConnectorPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The part number of the network connector.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
function."
|
|
::= { cpqRackNetConnectorEntry 8 }
|
|
|
|
|
|
cpqRackNetConnectorSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The spare part number of the network connector.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
function."
|
|
::= { cpqRackNetConnectorEntry 9 }
|
|
|
|
|
|
cpqRackNetConnectorFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware revision of the network connector.
|
|
|
|
The string will be empty if the network connector does not report the
|
|
firmware revision."
|
|
::= { cpqRackNetConnectorEntry 10 }
|
|
|
|
|
|
cpqRackNetConnectorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
passive(2),
|
|
active(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The type of network connector within the enclosure."
|
|
::= { cpqRackNetConnectorEntry 11 }
|
|
|
|
|
|
cpqRackNetConnectorLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The location of the network connector within the enclosure."
|
|
::= { cpqRackNetConnectorEntry 12 }
|
|
|
|
|
|
cpqRackNetConnectorPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the network connector described is present in the
|
|
enclosure."
|
|
::= { cpqRackNetConnectorEntry 13 }
|
|
|
|
|
|
cpqRackNetConnectorHasFuses OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The network connector contains fuses.
|
|
|
|
This will be true(2) is the network connector contains fuses.
|
|
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
|
specific information.
|
|
|
|
Match the cpqRackNetworkEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureFusTable to get complete
|
|
information on the fuses."
|
|
::= { cpqRackNetConnectorEntry 14 }
|
|
|
|
|
|
cpqRackNetConnectorEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The serial number of the enclosure containing the network connector.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackNetConnectorEntry 15 }
|
|
|
|
|
|
cpqRackNetConnectorTechnologyType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
passive(2),
|
|
active(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The type of network connector within the enclosure."
|
|
::= { cpqRackNetConnectorEntry 16 }
|
|
|
|
|
|
cpqRackNetConnectorDeviceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noconnect(1),
|
|
network(2),
|
|
fibrechannel(3),
|
|
sas(4),
|
|
inifiband(5),
|
|
pciexpress(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The type of interrconnect in the enclosure.
|
|
|
|
This will be -1 if it is not reported or can not be deteremined."
|
|
::= { cpqRackNetConnectorEntry 17 }
|
|
|
|
|
|
cpqRackSystemObjectIdentification OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The hardware identification string.
|
|
|
|
The string will reported by the rack firmware."
|
|
::= { cpqRackSysObjID 1 }
|
|
|
|
|
|
cpqRackNameChanged TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackSerialNum, cpqRackTrapSequenceNum }
|
|
--#SUMMARY "The rack name has changed to %s."
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Rack Serial Number: #"
|
|
--#TYPE "Rack name changed (22001)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackNameChangeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.RackTrapNoticeHandler"
|
|
DESCRIPTION "Rack name has changed. This trap signifies that an agent or utility has changed the name of the rack. Each of the server blades in each of the enclosure within the rack will be updated to reflect the new rack name. It may take several minutes for the rack name change to be propagated throughout the entire rack. User Action: None."
|
|
::= 22001
|
|
|
|
|
|
cpqRackEnclosureNameChanged TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureModel, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure name has changed to %s in rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Model: #"
|
|
--#TYPE "Enclosure name changed (22002)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclNameChangeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure name has changed. This trap signifies that an agent or utility has changed the name of an enclosure within the rack. Each of the components within the rack will be updated to reflect the new enclosure name. It may take several minutes for the enclosure name change to be propagated throughout the entire enclosure. User Action: None."
|
|
::= 22002
|
|
|
|
|
|
|
|
cpqRackEnclosureRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureModel, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s has been removed from rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Model: # $V7V#Serial Number: #"
|
|
--#TYPE "Enclosure removed (22003)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure has been removed. This trap signifies that an enclosure has been removed from the rack. User Action: None."
|
|
::= 22003
|
|
|
|
|
|
cpqRackEnclosureInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureModel, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s has been inserted into rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Model: # $V7V#Serial Number: #"
|
|
--#TYPE "Enclosure inserted (22004)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure has been inserted. This trap signifies that an enclosure has been inserted into the rack. User Action: None."
|
|
::= 22004
|
|
|
|
|
|
|
|
cpqRackEnclosureTempFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTempLocation, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to failed."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Location: #"
|
|
--#TYPE "Enclosure temperature failed (22005)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure temperature status has been set to failed. This trap signifies that a enclosure temperature sensor has been tripped indicating an overheat condition. User Action: Shutdown the enclosure and possibly the rack as soon as possible. Insure all fans are working properly and that air flow in the rack has not been blocked."
|
|
::= 22005
|
|
|
|
|
|
cpqRackEnclosureTempDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTempLocation, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to degraded."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
|
|
--#TYPE "Enclosure temperature degraded (22006)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure temperature status has been set to degraded. This trap signifies that an enclosure temperature sensor has been tripped indicating a possible overheat condition. User Action: Shutdown the enclosure and possibly the rack as soon as possible. Insure all fans are working properly and that air flow in the rack has not been blocked."
|
|
::= 22006
|
|
|
|
|
|
cpqRackEnclosureTempOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTempLocation, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to ok."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Position: #"
|
|
--#TYPE "Enclosure temperature ok (22007)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure temperature status has been set to ok. This trap signifies that an enclosure temperature sensor has returned to normal. User Action: None."
|
|
::= 22007
|
|
|
|
|
|
|
|
cpqRackEnclosureFanFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been set to failed."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
|
|
--#TYPE "Enclosure fan failed (22008)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible."
|
|
::= 22008
|
|
|
|
|
|
cpqRackEnclosureFanDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been set to degraded."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
|
|
--#TYPE "Enclosure fan degraded (22009)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure fan status has been set to degraded. This trap signifies that an enclosure fan has failed but other fans in the redundant fan group are still operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible."
|
|
::= 22009
|
|
|
|
|
|
cpqRackEnclosureFanOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been set to ok."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
|
|
--#TYPE "Enclosure fan ok (22010)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure fan status has been set to ok. This trap signifies that an enclosure fan has returned to normal operation. User Action: None."
|
|
::= 22010
|
|
|
|
cpqRackEnclosureFanRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been removed."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
|
|
--#TYPE "Enclosure fan removed (22011)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure fan has been removed. User Action: None."
|
|
::= 22011
|
|
|
|
|
|
cpqRackEnclosureFanInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been inserted."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Fan Location: #"
|
|
--#TYPE "Enclosure fan inserted (22012)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The enclosure fan has been inserted. User Action: None."
|
|
::= 22012
|
|
|
|
|
|
cpqRackPowerSupplyFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to failed."
|
|
--#ARGUMENTS {6,4,2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#PS Serial Number: # $V7V#Position: # $V10V#Enclosure Serial Number: #"
|
|
--#TYPE "Rack power supply failed (22013)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The power supply status has been set to failed. This trap signifies that a power supply has failed. User Action: Replace the power supply as soon as possible."
|
|
::= 22013
|
|
|
|
|
|
|
|
cpqRackPowerSupplyDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to degraded."
|
|
--#ARGUMENTS {6,4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#PS Serial Number: # $V7V#Position: # $V10V#Enclosure Serial Number: #"
|
|
--#TYPE "Rack power supply degraded (22014)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The power supply status has been set to degraded. This trap signifies that a power supply has degraded. User Action: Replace the power supply as soon as possible."
|
|
::= 22014
|
|
|
|
|
|
cpqRackPowerSupplyOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to ok."
|
|
--#ARGUMENTS {6,4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#PS Serial Number: # $V7V#PS Position: # $V10V#Enclosure Serial Number: #"
|
|
--#TYPE "Rack power supply ok (22015)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The power supply status has been set to ok. This trap signifies that a power supply has returned to normal operation. User Action: None."
|
|
::= 22015
|
|
|
|
|
|
cpqRackPowerSupplyRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been removed."
|
|
--#ARGUMENTS {6,4,2}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#PS Enclosure Name: # $V6V#PS Serial Number: # $V7V#PS Position: # $V10V#Enclosure Serial Number: #"
|
|
--#TYPE "Rack power supply removed (22016)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The power supply has been removed. User Action: None."
|
|
::= 22016
|
|
|
|
|
|
cpqRackPowerSupplyInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been inserted."
|
|
--#ARGUMENTS {6,4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#PS Enclosure Name: # $V6V#PS Serial Number: # $V7V#PS Position: # $V10V#Enclosure Serial Number: #"
|
|
--#TYPE "Rack power supply inserted (22017)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The power supply has been inserted. User Action: None."
|
|
::= 22017
|
|
|
|
|
|
cpqRackPowerSubsystemNotRedundant TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The power subsystem in enclosure %s in rack %s is no longer redundant."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
|
|
--#TYPE "Rack power subsystem not redundant (22018)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The rack power subsystem is no longer in a redundant state. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state."
|
|
::= 22018
|
|
|
|
|
|
cpqRackPowerSubsystemLineVoltageProblem TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplyInputLineStatus, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The rack power supply detected an input line voltage problem in power supply %s, enclosure %s, rack %s."
|
|
--#ARGUMENTS {5,4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#PS Position: # $V8V#Line Status: # $V10V#Enclosure Serial Number: #"
|
|
--#TYPE "Rack power supply input voltage problem (22019)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as soon as possible."
|
|
::= 22019
|
|
|
|
|
|
cpqRackPowerSubsystemOverloadCondition TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerEnclosureName, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The power subsystem in enclosure %s in rack %s is in an overload condition."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V7V#Serial Number: #"
|
|
--#TYPE "Rack power subsystem overload condition (22020)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The rack power subsystem overload condition. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state."
|
|
::= 22020
|
|
|
|
|
|
cpqRackPowerShedAutoShutdown TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "The server shutdown due to lack of power blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,4,2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Enclosure Serial Number: #"
|
|
--#TYPE "Server shutdown due to power shedding (22021)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.BladeTrapNoticeHandler"
|
|
DESCRIPTION "Server shutdown due to power shedding. The server blade was shutdown due to a lack of power. User Action: Check power connections or add power supplies."
|
|
::= 22021
|
|
|
|
|
|
|
|
cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,4,2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Serial Number: #"
|
|
--#TYPE "Server power on prevented to preserve redundancy (22022)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies."
|
|
::= 22022
|
|
|
|
|
|
cpqRackServerPowerOnFailedNotEnoughPower TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,4,2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Serial Number: #"
|
|
--#TYPE "Inadequate power to power on (22023)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Inadequate power to power on. There is not enough power to power on the server blade. User Action: Check power connections or add power supplies."
|
|
::= 22023
|
|
|
|
|
|
|
|
cpqRackServerPowerOnFailedEnclosureNotFound TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,4,2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Enclosure Serial Number: #"
|
|
--#TYPE "Inadequate power to power on (22024)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check server enclosure connections or add power supplies."
|
|
::= 22024
|
|
|
|
|
|
cpqRackServerPowerOnFailedPowerChassisNotFound TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,4,2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Serial Number: #"
|
|
--#TYPE "Inadequate power to power on (22025)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Inadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found. User Action: Check power enclosure connections or add power supplies."
|
|
::= 22025
|
|
|
|
|
|
cpqRackServerPowerOnManualOverride TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Server power on via manual override on blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Serial Number: #"
|
|
--#TYPE "Server power on via manual override (22026)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Server power on via manual override. The server blade was powered on by a manual override. User Action: None."
|
|
::= 22026
|
|
|
|
|
|
cpqRackFuseOpen TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureFuseLocation, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Fuse open fuse %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Location: # $V8V#Serial Number: #"
|
|
--#TYPE "Fuse open (22027)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Fuse open. The fuse has been tripped. User Action: Check enclosure and / or blade power connections and reset the fuse."
|
|
::= 22027
|
|
|
|
|
|
|
|
cpqRackServerBladeRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,6,4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Blade Name: # $V7V#Postion: # $V9V#Enclosure Serial Number: #"
|
|
--#TYPE "Server blade removed (22028)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeRemovedTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Server blade removed. The server blade has been removed from the enclosure. User Action: None."
|
|
::= 22028
|
|
|
|
|
|
|
|
cpqRackServerBladeInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5,6,4,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Blade Name: # $V7V#Postion: # $V9V#Serial Number: #"
|
|
--#TYPE "Server blade inserted (22029)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Server blade inserted. The server blade has been inserted into the enclosure. User Action: None."
|
|
::= 22029
|
|
|
|
|
|
|
|
cpqRackPowerChassisNotLoadBalanced TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Power subsystem not load balanced in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
|
|
--#TYPE "Power subsystem not load balanced (22030)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Power subsystem not load balanced. The power subsystem is out of balance for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed."
|
|
::= 22030
|
|
|
|
|
|
|
|
cpqRackPowerChassisDcPowerProblem TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Power subsystem DC power problem in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
|
|
--#TYPE "Power subsystem DC power problem (22031)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
|
|
::= 22031
|
|
|
|
|
|
|
|
cpqRackPowerChassisAcFacilityPowerExceeded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Power subsystem AC facility input power exceeded in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
|
|
--#TYPE "Power subsystem AC facility input power exceeded (22032)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Power subsystem AC facility input power exceeded. There is a power subsystem Power subsystem AC facility input power exceeded for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
|
|
::= 22032
|
|
|
|
|
|
cpqRackPowerUnknownPowerConsumption TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Unknown power consumption in rack %s."
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Serial Number: #"
|
|
--#TYPE "Unknown power consumption (22033)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.RackTrapNoticeHandler"
|
|
DESCRIPTION "Unknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
|
|
::= 22033
|
|
|
|
|
|
|
|
cpqRackPowerChassisLoadBalancingWireMissing TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Power subsystem load balancing wire missing for enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
|
|
--#TYPE "Power subsystem load balancing wire missing (22034)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Power subsystem load balancing wire missing. The power subsystem load balancing wire missing. User Action: Connect the load balancing wire."
|
|
::= 22034
|
|
|
|
|
|
|
|
cpqRackPowerChassisTooManyPowerChassis TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Power subsystem has too may power enclosures %s, in rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
|
|
--#TYPE "Power subsystem has too may power enclosures (22035)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.RackTrapNoticeHandler"
|
|
DESCRIPTION "Power subsystem has too may power enclosures. The maximum number of power enclosures has been exceeded. User Action: Remove the extra power enclosure."
|
|
::= 22035
|
|
|
|
|
|
cpqRackPowerChassisConfigError TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#SUMMARY "Power subsystem has been improperly configured in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4,2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
|
|
--#TYPE "Power subsystem improperly configured (22036)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Power subsystem improperly configured. The power subsystem has been improperly configured. User Action: Check the cabling of the power enclosure."
|
|
::= 22036
|
|
|
|
|
|
|
|
cpqRackEnclosureManagerDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Enclosure manager degraded (22037)"
|
|
--#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The Onboard Administrator status has been set to degraded. This trap signifies that an Onboard Administrator has failed but the other Onboard Administrator is still operating.
|
|
|
|
User Action: Replace the Onboard Administrator as soon as possible."
|
|
::= 22037
|
|
|
|
|
|
|
|
cpqRackEnclosureManagerOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Onboard Administrator ok (22038)"
|
|
--#SUMMARY "The Onboard Administrator %s in rack %s has been set to ok."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The Onboard Administrator status has been set to ok. This trap signifies that an Onboard Administrator has returned to normal operation.
|
|
|
|
User Action: None."
|
|
::= 22038
|
|
|
|
|
|
|
|
cpqRackEnclosureManagerRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Onboard Administrator removed (22039)"
|
|
--#SUMMARY "The Onboard Administrator %s in rack %s has been removed."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The Onboard Administrator has been removed.
|
|
|
|
User Action: None."
|
|
::= 22039
|
|
|
|
|
|
cpqRackEnclosureManagerInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Onboard Administrator inserted (22040)"
|
|
--#SUMMARY "The Onboard Administrator %s in rack %s has been inserted."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The Onboard Administrator has been inserted.
|
|
|
|
User Action: None."
|
|
::= 22040
|
|
|
|
|
|
|
|
cpqRackManagerPrimaryRole TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Onboard Administrator has taken the role of primary (UID) (22041)"
|
|
--#SUMMARY "Onboard Administrator has taken the role of primary, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 3}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.OARoleTrapHandler"
|
|
DESCRIPTION "The Onboard Administrator has taken the role of primary.
|
|
|
|
User Action: None."
|
|
::= 22041
|
|
|
|
|
|
|
|
cpqRackServerBladeEKeyingFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server Blade ekeying failed (22042)"
|
|
--#SUMMARY "Server blade %s ekeying failed in position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.BladeTrapNoticeHandler"
|
|
DESCRIPTION "The server blade e-keying has failed. This trap signifies that a server blade e-keying has failed and there is a port mapping problem between a server mezz card and the interconnect.
|
|
|
|
User Action: Reconfigure server blade mezz cards."
|
|
::= 22042
|
|
|
|
|
|
|
|
cpqRackServerBladeEKeyingOK TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server Blade ekeying ok (22043)"
|
|
--#SUMMARY "Server blade %s ekeying is ok in position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.BladeTrapNoticeHandler"
|
|
DESCRIPTION "The server blade e-keying is ok.
|
|
|
|
This trap signifies that a server blade e-keying has returned to
|
|
normal operation.
|
|
|
|
User Action: None."
|
|
::= 22043
|
|
|
|
|
|
|
|
cpqRackNetConnectorRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Interconnect removed (22044)"
|
|
--#SUMMARY "Interconnect %s removed from position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Interconnect removed.
|
|
|
|
The interconnect has been removed from the enclosure.
|
|
|
|
User Action: None."
|
|
::= 22044
|
|
|
|
|
|
|
|
cpqRackNetConnectorInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Interconnect inserted (22045)"
|
|
--#SUMMARY "Interconnect %s inserted into position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "Interconnect inserted.
|
|
|
|
The interconnect has been inserted into the enclosure.
|
|
|
|
User Action: None."
|
|
::= 22045
|
|
|
|
|
|
|
|
cpqRackNetConnectorFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Interconnect failed (22046)"
|
|
--#SUMMARY "Interconnect %s failed in position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The interconnect status has been set to failed.
|
|
|
|
This trap signifies that a interconnect has failed.
|
|
|
|
User Action: Replace the interconnect as soon as possible."
|
|
::= 22046
|
|
|
|
|
|
|
|
cpqRackNetConnectorDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Interconnect degraded (22047)"
|
|
--#SUMMARY "Interconnect %s degraded in position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The interconnect status has been set to degraded.
|
|
|
|
This trap signifies that a interconnect has degraded.
|
|
|
|
User Action: Replace the interconnect as soon as possible."
|
|
::= 22047
|
|
|
|
|
|
|
|
cpqRackNetConnectorOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Interconnect ok (22048)"
|
|
--#SUMMARY "Interconnect %s ok in position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
DESCRIPTION "The interconnect status has been set to ok.
|
|
|
|
This trap signifies that a interconnect has returned to
|
|
normal operation.
|
|
|
|
User Action: None."
|
|
::= 22048
|
|
|
|
|
|
|
|
cpqRackServerBladeToLowPower TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server Blade requested to low power (22049)"
|
|
--#SUMMARY "Server blade %s requested to low power in position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
|
|
DESCRIPTION "The server blade requested to low power.
|
|
|
|
User Action: None."
|
|
::= 22049
|
|
|
|
|
|
|
|
cpqRackServerBladeRemoved2 TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server blade removed (22050)"
|
|
--#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeRemovedTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Server Blade Serial Number: # $V11V#Server Blade Unique Id: # $V12V#Trap Sequence Number: #"
|
|
DESCRIPTION "Server blade removed. The server blade has been removed from the enclosure.
|
|
|
|
User Action: None."
|
|
::= 22050
|
|
|
|
|
|
|
|
cpqRackServerBladeInserted2 TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server blade inserted (22051)"
|
|
--#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
|
|
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Server Blade Serial Number: # $V11V#Server Blade Unique Id: # $V12V#Trap Sequence Number: #"
|
|
DESCRIPTION "Server blade inserted.
|
|
|
|
The server blade has been inserted into the enclosure.
|
|
|
|
User Action: None."
|
|
::= 22051
|
|
|
|
|
|
|
|
cpqRackServerBladeStatusRepaired TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladeProductId, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server blade repaired (22052)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s status has changed to OK."
|
|
--#ARGUMENTS {5, 7, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Product Id: # $V8V#Server Blade Position: # $V9V#Server Blade Spare PartNumber: # $V10V#Enclosure Serial Number: # $V11V#Server Blade Serial Number: # $V12V#Server Blade Id: # $V13V#Enclosure Trap Sequence Number: #"
|
|
DESCRIPTION "Server blade repaired.
|
|
|
|
The server blade status has changed to OK.
|
|
|
|
User Action: None."
|
|
::= 22052
|
|
|
|
|
|
|
|
cpqRackServerBladeStatusDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladeProductId, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeFaultMajor, cpqRackServerBladeFaultMinor, cpqRackServerBladeFaultDiagnosticString, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server blade health status degraded (22053)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s health status has changed to degraded. Reason: %s."
|
|
--#ARGUMENTS {5, 7, 4, 2, 14}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Product Id: # $V8V#Server Blade Position: # $V9V#Server Blade Spare PartNumber: # $V10V#Enclosure Serial Number: # $V11V#Server Blade Serial Number: # $V12V#Server Blade Id: # $V13V#Server Blade Fault Major: # $V14V#Server Blade Fault Minor: # $V15V#Blade Fault Diagnostic String: # $V16V#Enclosure Trap Sequence Number: #"
|
|
DESCRIPTION "Server blade health status Degraded.
|
|
|
|
The server blade health status has changed to Degraded.
|
|
|
|
User Action: Check blade server and enclosure SYSLOG."
|
|
::= 22053
|
|
|
|
|
|
|
|
cpqRackServerBladeStatusCritical TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladeProductId, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeFaultMajor, cpqRackServerBladeFaultMinor, cpqRackServerBladeFaultDiagnosticString, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server blade health status critical (22054)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s health status has changed to critical. Reason: %s."
|
|
--#ARGUMENTS {5, 7, 4, 2, 14}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Product Id: # $V8V#Server Blade Position: # $V9V#Server Blade Spare PartNumber: # $V10V#Enclosure Serial Number: # $V11V#Server Blade Serial Number: # $V12V#Server Blade Id: # $V13V#Server Blade Fault Major: # $V14V#Server Blade Fault Minor: # $V15V#Blade Fault Diagnostic String: # $V16V#Enclosure Trap Sequence Number: #"
|
|
DESCRIPTION "Server blade health status Critical.
|
|
|
|
The server blade health status has changed to Critical.
|
|
|
|
User Action: Check blade server and enclosure SYSLOG."
|
|
::= 22054
|
|
|
|
|
|
|
|
cpqRackServerBladeGrpCapTimeout TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server blade not responding to group capping requests (22055)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s is not responding to requests from the enclosure group capper."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Enclosure Trap Sequence Number: #"
|
|
|
|
DESCRIPTION "The server blade is not responding to the group capper.
|
|
|
|
The server blade is not responding to capping requests from the enclosure group capper
|
|
|
|
User Action: Reset the iLO management processor."
|
|
::= 22055
|
|
|
|
|
|
|
|
cpqRackServerBladeUnexpectedShutdown TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade unexpected shutdown (22056)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has unexpectedly shutdown."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Enclosure Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade shutdown unexpectadly.
|
|
|
|
An unexpected shutdown event has occurred for this server blade.
|
|
|
|
User Action: Check blade server and enclosure SYSLOG."
|
|
::= 22056
|
|
|
|
|
|
|
|
cpqRackServerBladeMangementControllerFirmwareUpdating TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeManagementDeviceFirmwareFlashingStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
--#TYPE "Server blade management controller firmware update started (22057)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has started updating it's management controller firmware."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Firmware Flashing Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade's management controller firmware updating.
|
|
|
|
This server blade's management controller has started updating it's firmware.
|
|
|
|
User Action: None."
|
|
::= 22057
|
|
|
|
|
|
|
|
cpqRackServerBladeMangementControllerFirmwareUpdateComplete TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeManagementDeviceFirmwareFlashingStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade management controller firmware update completed (22058)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has finished updating it's management controller firmware."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Firmware Flashing Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade's management controller firmware update has completed.
|
|
|
|
This server blade's management controller has finished updating it's firmware.
|
|
|
|
User Action: None."
|
|
::= 22058
|
|
|
|
|
|
|
|
cpqRackServerBladeSystemBIOSFirmwareUpdating TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeSystemBIOSFlashingStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade system BIOS firmware update started (22059)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has started updating it's system BIOS firmware."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Firmware Flashing Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade's system BIOS firmware updating.
|
|
|
|
This server blade's system BIOS has started updating.
|
|
|
|
User Action: None."
|
|
::= 22059
|
|
|
|
|
|
|
|
cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeSystemBIOSFlashingStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade system BIOS firmware update completed (22060)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has completed updating it's system BIOS firmware."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Firmware Flashing Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade's system BIOS firmware update complete.
|
|
|
|
This server blade's system BIOS has completed updating.
|
|
|
|
User Action: None."
|
|
::= 22060
|
|
|
|
|
|
|
|
cpqRackServerBladeFrontIOBlankingActive TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeFrontIOBlankingModeStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade front IO blanking active (22061)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has disabled front IO."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Blade Front IO Blanking Mode Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade has disabled front IO ports.
|
|
|
|
Front IO blanking status has changed to active for this server blade.
|
|
|
|
User Action: None."
|
|
::= 22061
|
|
|
|
|
|
|
|
cpqRackServerBladeRemoteFrontIOBlankingInactive TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeFrontIOBlankingModeStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade front IO blanking inactive (22062)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has enabled front IO."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Blade Front IO Blanking Mode Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade has front IO blanking mode now inactive.
|
|
|
|
Front IO blanking status has changed to inactive for this server blade.
|
|
|
|
User Action: None."
|
|
::= 22062
|
|
|
|
|
|
|
|
cpqRackServerBladeDiagnosticAdaptorInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeDiagnosticAdaptorPresence, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade diagnostic adaptor inserted (22063)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s diagnostic adaptor inserted."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Server Blade Diagnostic Adaptor Presence: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade diagnostic adaptor inserted.
|
|
|
|
Blade diagnostic adaptor status has changed to inserted for this server blade.
|
|
|
|
User Action: None."
|
|
::= 22063
|
|
|
|
|
|
|
|
cpqRackServerBladeDiagnosticAdaptorRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeDiagnosticAdaptorPresence, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade diagnostic adaptor removed (22064)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s diagnostic adaptor removed."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Server Blade Diagnostic Adaptor Presence: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade diagnostic adaptor removed.
|
|
|
|
Blade diagnostic adaptor status has changed to removed for this server blade.
|
|
|
|
User Action: None."
|
|
::= 22064
|
|
|
|
|
|
|
|
cpqRackServerBladeEnteredPXEBootMode TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePXEBootModeStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade has entered PXE Boot Mode (22065)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has entered PXE Boot Mode."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade PXE Boot Mode Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade has entered PXE Boot Mode.
|
|
|
|
Server blade Pre-Boot-eXecution (PXE) Mode started.
|
|
|
|
User Action: None."
|
|
::= 22065
|
|
|
|
|
|
|
|
cpqRackServerBladeExitedPXEBootMode TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePXEBootModeStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade has exited PXE Boot Mode (22066)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has exited PXE Boot Mode."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade PXE Boot Mode Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade has exited PXE Boot Mode.
|
|
|
|
Server blade Pre-Boot-eXecution (PXE) Mode exited.
|
|
|
|
User Action: None."
|
|
::= 22066
|
|
|
|
|
|
|
|
cpqRackServerBladeWarmReset TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePOSTStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade warm reset occurred (22067)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has been warm reset."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade POST Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade has been warm reset.
|
|
|
|
Server blade has experienced a warm reset.
|
|
|
|
User Action: None."
|
|
::= 22067
|
|
|
|
|
|
|
|
cpqRackServerBladePOSTCompleted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePOSTStatus, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade system BIOS POST completed (22068)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s system BIOS POST completed."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade POST Status: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade system BIOS POST complete.
|
|
|
|
Server blade has completed system BIOS Power-On-Self-Test (POST).
|
|
|
|
User Action: None."
|
|
::= 22068
|
|
|
|
|
|
|
|
cpqRackServerBladePoweredOn TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePowered, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade has powered on (22069)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has powered on."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade Powered: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade has powered on.
|
|
|
|
User Action: None."
|
|
::= 22069
|
|
|
|
|
|
|
|
cpqRackServerBladePoweredOff TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePowered, cpqRackCommonEnclosureTrapSequenceNum }
|
|
|
|
--#TYPE "Server blade has powered off (22070)"
|
|
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has powered off."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
--#CATEGORY "Proliant Rack Events"
|
|
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade Powered: # $V13V#Trap Number: #"
|
|
|
|
DESCRIPTION "Server blade has powered off.
|
|
|
|
User Action: None."
|
|
::= 22070
|
|
|
|
|
|
|
|
cpqRackInformationalEAETrap TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
|
|
|
|
--#TYPE "Generic EAE Informational trap"
|
|
|
|
--#SUMMARY "%s"
|
|
|
|
--#ARGUMENTS {6}
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "EAE Informational trap"
|
|
::= 22071
|
|
|
|
|
|
cpqRackMinorEAETrap TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
|
|
|
|
--#TYPE "Generic EAE Minor trap"
|
|
|
|
--#SUMMARY "%s"
|
|
|
|
--#ARGUMENTS {6}
|
|
|
|
--#SEVERITY MINOR
|
|
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "EAE Minor trap"
|
|
::= 22072
|
|
|
|
|
|
cpqRackMajorEAETrap TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
|
|
|
|
--#TYPE "Generic EAE Major trap"
|
|
|
|
--#SUMMARY "%s"
|
|
|
|
--#ARGUMENTS {6}
|
|
|
|
--#SEVERITY MAJOR
|
|
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "EAE Major trap"
|
|
::= 22073
|
|
|
|
|
|
cpqRackCriticalEAETrap TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
|
|
|
|
--#TYPE "Generic EAE Critical trap"
|
|
|
|
--#SUMMARY "%s"
|
|
|
|
--#ARGUMENTS {6}
|
|
|
|
--#SEVERITY CRITICAL
|
|
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "EAE Critical trap"
|
|
::= 22074
|
|
|
|
|
|
cpqRackPowerMinorEAETrap TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
|
|
|
|
--#TYPE "Generic Power Subsystem EAE Minor trap"
|
|
|
|
--#SUMMARY "%s"
|
|
|
|
--#ARGUMENTS {6}
|
|
|
|
--#SEVERITY MINOR
|
|
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "FlexFabric Cmdr Power Subsystem Minor trap.
|
|
User Action: For FlexFabric Cmdr, please refer to product documentation for
|
|
possible corrective actions."
|
|
::= 22075
|
|
|
|
|
|
cpqRackPowerMajorEAETrap TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
|
|
|
|
--#TYPE "Generic Power Subsystem EAE Major trap"
|
|
|
|
--#SUMMARY "%s"
|
|
|
|
--#ARGUMENTS {6}
|
|
|
|
--#SEVERITY MAJOR
|
|
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "FlexFabric Cmdr Power Subsystem Major trap.
|
|
User Action: For FlexFabric Cmdr, please refer to product documentation for
|
|
possible corrective actions."
|
|
::= 22076
|
|
|
|
|
|
cpqRackPowerCriticalEAETrap TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
|
|
|
|
--#TYPE "Generic Power Subsystem EAE Critical trap"
|
|
|
|
--#SUMMARY "%s"
|
|
|
|
--#ARGUMENTS {6}
|
|
|
|
--#SEVERITY CRITICAL
|
|
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "FlexFabric Cmdr Power Subsystem Critical trap.
|
|
User Action: For FlexFabric Cmdr, please refer to product documentation for
|
|
possible corrective actions."
|
|
::= 22077
|
|
|
|
|
|
END
|
|
|