-- SECTION 1: Top Level Definitions
CENTILLION-DOT5-EXTENSIONS-MIB DEFINITIONS ::= BEGIN
-- Centillion IEEE 802.5 Token Ring Extensions MIB Release 2.0.1
-- Revision 03/20/96
-- Copyright 1994-96 Bay Networks, Inc.
-- All rights reserved.
-- This Bay Networks SNMP Management Information Base Specification
-- (Specification) embodies Bay Networks' confidential and
-- proprietary intellectual property. Bay Networks retains all
-- title and ownership in the Specification, including any
-- revisions.
-- This Specification is supplied "AS IS," and Bay Networks makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
-- Imports
IMPORTS
OBJECT-TYPE
FROM RFC-1212
extensions, EnableIndicator
FROM CENTILLION-ROOT-MIB;
-- Textual Conventions
-- The following identifies the configuration of the ring port.
TrPortConnType ::=
INTEGER {
trPortDTR(1), -- port has a direct connection to
-- a ring station
tr4PortStation(2), -- port is a standard ring station
trPortRiRoPhantom(3), -- port is connected to Ring-In or
-- Ring-Out of a MAU and provides
-- phantom drive
trPortRiRoNoPhantom(4), -- port is Ring-In/Ring-Out and
-- does not provide phantom drive
trPortHub(16), -- detects phantom, NICs attached
-- to port
trPortStation(17), -- sources phantom, attached to a
-- concentrator port
trPortBay_Ro(18), -- connects to a Bay Hub RI port,
-- sources phantom
trPortBay_Ri(19), -- connects to a Bay Hub RO port,
-- detects phantom
trPortOther_Ro(20), -- connects to a non-Bay Hub RI
-- port, detects phantom
trPortOther_Ri(21), -- connects to a non-Bay Hub RO
-- port, source phantom
trPortFdtr_hub(22), -- full duplex stations attached
-- to port, detects phantom
trPortFdtr_station(23), -- full duplex, sources phantom,
-- used for inter-switch link
trPortAutoStationHub(24) -- Automatically determines
-- Station or hub connection type
}
-- Groups
cnDot5Extensions OBJECT IDENTIFIER ::= { extensions 3 }
-- SECTION 2: MIB Objects
-- Centillion Token Ring Extensions Table
cnDot5ExtnTable OBJECT-TYPE
SYNTAX SEQUENCE OF CnDot5ExtnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains Token Ring interface
parameters and state variables, one entry
per 802.5 interface."
::= { cnDot5Extensions 1 }
cnDot5ExtnEntry OBJECT-TYPE
SYNTAX CnDot5ExtnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Token Ring status and parameter
values for an 802.5 interface."
INDEX { cnDot5ExtnIfIndex }
::= { cnDot5ExtnTable 1 }
CnDot5ExtnEntry ::= SEQUENCE {
cnDot5ExtnIfIndex
INTEGER,
cnDot5ExtnPortConnType
TrPortConnType,
cnDot5ExtnPortSpeedSense
EnableIndicator,
cnDot5ExtnAdminRingSpeed
INTEGER
}
cnDot5ExtnIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.5 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6],
for the same interface."
::= { cnDot5ExtnEntry 1 }
cnDot5ExtnPortConnType OBJECT-TYPE
SYNTAX TrPortConnType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of connection used on this port. Setting a value
to this object requires the port to be reset and re-opened
before taking effect. Allowable connections for TR4 are:
Station - (default for TR4) the port is configured as a
standard ring station,
Ring-In/Ring-Out - the port is connected to the Ring-In
or Ring-Out port of a MAU with an
appropriate cable.
DTR - the port has a direct connection to a ring station.
A different set of connection type for TR8 are :
Hub, Station, Bay/SNPX RO, Bay/SNPX RI, Other RO,
Other RI, FDTR Hub, FDTR Station"
::= { cnDot5ExtnEntry 2 }
cnDot5ExtnPortSpeedSense OBJECT-TYPE
SYNTAX EnableIndicator
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether speed sensing is enabled (default),
or disabled on the port. This is used in conjuection with
the RingSpeed to either match or force to the configured
speed."
::= { cnDot5ExtnEntry 3 }
cnDot5ExtnAdminRingSpeed OBJECT-TYPE
SYNTAX INTEGER {
autoDetect(1),
forceFourMegabit(2),
forceSixteenMegabit(3),
matchFourMegabit(4),
matchSixteenMegabit(5),
force32Megabit(6),
autoDetect16or32(7),
autoDetect4or16or32(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The configured ring speed of the port. The speed will take
effect on the next opening of the ring. The speeds of
'force' indicates that the port should enter the ring
regardless of the current ring speed. The 'match' speeds
indcate the the port should insert at the configured speed,
only if the current ring speed matches the port speed.
The operational ring speed may be obtained by the usual
dot5RingSpeed object. The 'auto detect' indicates that the
ring detect and insert at the current ring speed."
::= { cnDot5ExtnEntry 4 }
-- Centillion 5000 Token Ring Extention Table
cnS5TrExtnTable OBJECT-TYPE
SYNTAX SEQUENCE OF CnS5TrExtnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains additional Token Ring interface
parameters and state variables, one entry per
802.5 interface for 5000BH token ring cards."
::= { cnDot5Extensions 2 }
cnS5TrExtnEntry OBJECT-TYPE
SYNTAX CnS5TrExtnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Token Ring additional status and parameter
values for an 802.5 interface for 5000BH token ring
cards."
INDEX { cnS5TrExtnIfIndex }
::= { cnS5TrExtnTable 1 }
CnS5TrExtnEntry ::= SEQUENCE {
cnS5TrExtnIfIndex
INTEGER,
cnS5TrExtnFrontPortConnect
INTEGER,
cnS5TrExtnOperBkplaneAtt
INTEGER
}
cnS5TrExtnIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.5 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6],
for the same interface."
::= { cnS5TrExtnEntry 1 }
cnS5TrExtnFrontPortConnect OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disable(2),
enable(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If enabled, front port insertion is allowed. This setting
has no meaning other than in tr8PortHub mode."
::= { cnS5TrExtnEntry 2 }
cnS5TrExtnOperBkplaneAtt OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notCapable(2),
capableAndAttached(3),
capableAndDetached(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the operating backplane
attachment state of a token ring port. For the
ports that do not have backplane attachment
capability, notCapable(2) is returned."
::= { cnS5TrExtnEntry 3 }
END