mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-17 16:03:04 +00:00
346 lines
11 KiB
Plaintext
Executable File
346 lines
11 KiB
Plaintext
Executable File
SS-TRAP-MIB
|
|
--FORCE-INCLUDE <mib.h>
|
|
--FORCE-INCLUDE <snmpdefs.h>
|
|
--FORCE-INCLUDE <snmpstat.h>
|
|
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
-- TITLE: CS 1000 Signaling Server Trap MIB
|
|
--
|
|
-- Author: Joseph Abraham
|
|
--
|
|
-- This specification has been successfully compiled with the following
|
|
-- MIB compilers:
|
|
-- a) Wind River Systems Emissary SNMP MIB Compiler, version 7.0
|
|
--
|
|
-- Note:
|
|
-- This document is maintained as a text file.
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, enterprises, MODULE-IDENTITY FROM SNMPv2-SMI
|
|
RowPointer, DateAndTime FROM SNMPv2-TC
|
|
TRAP-TYPE FROM RFC-1215
|
|
DisplayString FROM RFC1213-MIB;
|
|
|
|
sstrapmib MODULE-IDENTITY
|
|
LAST-UPDATED "0302191600Z"
|
|
ORGANIZATION "Nortel Networks"
|
|
CONTACT-INFO
|
|
"Postal: Nortel Networks
|
|
250 Sidney Street
|
|
Belleville ON K8P 3Z3
|
|
Tel : +1 613 967 5000"
|
|
DESCRIPTION
|
|
"The Signaling Server SNMP trap MIB."
|
|
::= { sigserv 50 }
|
|
|
|
-- LAST-UPDATED field is in UTC Time Format
|
|
-- YYMMDDHHMMZ
|
|
-- where: YY - last two digits of year MM - month (01 through 12)
|
|
-- DD - day of month (01 through 31) HH - hours (00 through 23)
|
|
-- MM - minutes (00 through 59)
|
|
-- Z - the character "Z" denotes Greenwich Mean Time (GMT).
|
|
|
|
-- For example, "0302191600Z" represents 4:00pm GMT on 19 February 2003.
|
|
|
|
nt OBJECT IDENTIFIER ::= { enterprises 562 }
|
|
-- nt. The name under which 562 is registered with IANA.
|
|
|
|
meridian OBJECT IDENTIFIER ::= { nt 3 }
|
|
-- Meridian. The value assigned for Meridian.
|
|
|
|
sigserv OBJECT IDENTIFIER ::= { meridian 21 }
|
|
-- sigserv. The value assigned for Signaling Server.
|
|
|
|
ssmib OBJECT IDENTIFIER ::= { sigserv 5 }
|
|
|
|
fm-Info OBJECT IDENTIFIER ::= { ssmib 4 }
|
|
|
|
|
|
-- General definitions
|
|
|
|
AlarmSeverity ::= INTEGER {
|
|
indeterminate (0),
|
|
critical (1),
|
|
major (2),
|
|
minor (3),
|
|
warning (4),
|
|
cleared (5)
|
|
}
|
|
|
|
AlarmType ::= INTEGER {
|
|
communications (1),
|
|
qualityOfService (2),
|
|
processing (3),
|
|
equipment (4),
|
|
security (5),
|
|
operator (6),
|
|
debug (7),
|
|
unknown (8)
|
|
}
|
|
|
|
|
|
fmSSAlarmTraps OBJECT IDENTIFIER ::= { fm-Info 1 }
|
|
|
|
|
|
-- Fault management alarm types
|
|
|
|
fmSScriticalAlarm TRAP-TYPE
|
|
ENTERPRISE fmSSAlarmTraps
|
|
VARIABLES { componentRowPointer, componentName, eventTime,
|
|
activeListStatus, severity, alarmType, probableCause,
|
|
ntpIndex, commentData }
|
|
DESCRIPTION
|
|
"This trap is used to provide a real time indication
|
|
of a critical alarm condition. The variables listed
|
|
in VARIABLES clause are defined in `fmSSAlarmInfo'
|
|
group are present in all critical alarms."
|
|
::= 1
|
|
|
|
fmSSmajorAlarm TRAP-TYPE
|
|
ENTERPRISE fmSSAlarmTraps
|
|
VARIABLES { componentRowPointer, componentName, eventTime,
|
|
activeListStatus, severity, alarmType, probableCause,
|
|
ntpIndex, commentData }
|
|
DESCRIPTION
|
|
"This trap is used to provide a real time indication
|
|
of a major alarm condition. The variables listed in
|
|
VARIABLES clause are defined in `fmSSAlarmInfo' group
|
|
are present in all major alarms."
|
|
::= 2
|
|
|
|
fmSSminorAlarm TRAP-TYPE
|
|
ENTERPRISE fmSSAlarmTraps
|
|
VARIABLES { componentRowPointer, componentName, eventTime,
|
|
activeListStatus, severity, alarmType, probableCause,
|
|
ntpIndex, commentData }
|
|
DESCRIPTION
|
|
"This trap is used to provide a real time indication
|
|
of a minor alarm condition. The variables listed in
|
|
VARIABLES clause are defined in `fmSSAlarmInfo' group
|
|
are present in all minor alarms."
|
|
::= 3
|
|
|
|
fmSSwarningAlarm TRAP-TYPE
|
|
ENTERPRISE fmSSAlarmTraps
|
|
VARIABLES { componentRowPointer, componentName, eventTime,
|
|
activeListStatus, severity, alarmType, probableCause,
|
|
ntpIndex, commentData }
|
|
DESCRIPTION
|
|
"This trap is used to provide a real time indication
|
|
of a warning alarm condition. The variables listed in
|
|
VARIABLES clause are defined in `fmSSAlarmInfo' group
|
|
are present in all warning alarms."
|
|
::= 4
|
|
|
|
fmSSclearedAlarm TRAP-TYPE
|
|
ENTERPRISE fmSSAlarmTraps
|
|
VARIABLES { componentRowPointer, componentName, eventTime,
|
|
activeListStatus, severity, alarmType, probableCause,
|
|
ntpIndex, commentData }
|
|
DESCRIPTION
|
|
"This trap is used to provide a real time indication
|
|
of a cleared alarm. The variables listed in VARIABLES
|
|
clause are defined in `fmSSAlarmInfo' group are present
|
|
in all cleared alarms."
|
|
::= 5
|
|
|
|
fmSSindeterminateAlarm TRAP-TYPE
|
|
ENTERPRISE fmSSAlarmTraps
|
|
VARIABLES { componentRowPointer, componentName, eventTime,
|
|
activeListStatus, severity, alarmType, probableCause,
|
|
ntpIndex, commentData }
|
|
DESCRIPTION
|
|
"This trap is used to provide a real time indication
|
|
of a indeterminate alarm condition. The variables
|
|
listed in VARIABLES clause are defined in
|
|
`fmSSAlarmInfo' group are present in all
|
|
indeterminate alarms."
|
|
::= 6
|
|
|
|
|
|
fmSSAlarmInfo OBJECT IDENTIFIER ::= { fmSSAlarmTraps 7}
|
|
|
|
componentRowPointer OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A pointer to the RowStatus variable of the component
|
|
emitting the alarm, on a system where a component is
|
|
generally a table entry."
|
|
::= { fmSSAlarmInfo 1 }
|
|
|
|
componentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This convention is used where each component can be
|
|
uniquely referenced by a type and instance name
|
|
(at the console interface also). The textual content
|
|
of this may be limited to the string representation
|
|
of the OID."
|
|
::= { fmSSAlarmInfo 2 }
|
|
|
|
eventTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time at which the alarmed event occurred."
|
|
::= { fmSSAlarmInfo 3 }
|
|
|
|
activeListStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { message(0), set(1), clear(2) }
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The active alarm list status. This may be used by the
|
|
Manager to add (on receiving a set) and delete (on
|
|
receiving a clear) alarms from the alarm display."
|
|
::= { fmSSAlarmInfo 4 }
|
|
|
|
severity OBJECT-TYPE
|
|
SYNTAX AlarmSeverity
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the alarm which should indicate what
|
|
priority should be given for fixing this problem. All
|
|
values are OSI-defined; refer to CCITT X.733/ISO 10164-4
|
|
for a more complete description."
|
|
::= { fmSSAlarmInfo 5 }
|
|
|
|
alarmType OBJECT-TYPE
|
|
SYNTAX AlarmType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm type field as defined by OSI which is used
|
|
to indicate a broad category of what is wrong. The
|
|
first 6 values are OSI-defined; refer to CCITT X.733/ISO
|
|
10164-4 (for the first 5) and CCITT X.736/ISO 10164-4
|
|
(for the last) for a more complete description. The
|
|
value 'operator' is used when an alarm is issued due
|
|
to an operator command. The values 'debug' and 'unknown'
|
|
are for compatibility with older switches and are used
|
|
for debugging alarms and for those which do not fit
|
|
any of the above, respectively."
|
|
::= { fmSSAlarmInfo 6}
|
|
|
|
probableCause OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- Start of OSI-defined values
|
|
-- (see X.733/ ISO 10165-3)
|
|
lossOfSignal(0),
|
|
lossOfFrame(1),
|
|
framingError(2),
|
|
localTransmissionError(3),
|
|
remoteTransmissionError(4),
|
|
callEstablishmentError(5),
|
|
degradedSignal(6),
|
|
commSubsystemFailure(7),
|
|
commProtocolError(8),
|
|
lanError(9),
|
|
dteDceInterfaceError(10),
|
|
responseTimeExcessive(20),
|
|
queueSizeExceeded(21),
|
|
bandwidthReduced(22),
|
|
retransmissionRateReduced(23),
|
|
thresholdCrossed(24),
|
|
performanceDegraded(25),
|
|
congestion(26),
|
|
atOrNearCapacity(27),
|
|
storageCapacityProblem(40),
|
|
versionMismatch(41),
|
|
corruptData(42),
|
|
cpuCyclesLimitExceeded(43),
|
|
softwareError(44),
|
|
softwareProgramError(45),
|
|
softwareProgramTermination(46),
|
|
fileError(47),
|
|
outOfMemory(48),
|
|
underlyingResourceUnavail(49),
|
|
applicationSubsystemFailure(50),
|
|
configurationError(51),
|
|
powerProblem(60),
|
|
timingProblem(61),
|
|
processorProblem(62),
|
|
datasetModemError(63),
|
|
multiplexorProblem(64),
|
|
receiverFailure(65),
|
|
transmitterFailure(66),
|
|
outputDeviceError(67),
|
|
inputDeviceError(68),
|
|
ioDeviceError(69),
|
|
equipmentFailure(70),
|
|
adapterError(71),
|
|
-- OSI-defined values continued (see X.736)
|
|
duplicateInfo(80),
|
|
infoMissing(81),
|
|
infoModification(82),
|
|
infoOutOfSequence(83),
|
|
unexpectedInfo(84),
|
|
denialOfService(90),
|
|
outOfService(91),
|
|
proceduralError(92),
|
|
otherOperational(93),
|
|
cableTamper(100),
|
|
intrusionDetection(101),
|
|
otherPhysical(102),
|
|
authenticationFailure(110),
|
|
breachOfConfidence(111),
|
|
nonRepudiationFailure(112),
|
|
unauthorizedMAX-ACCESS(113),
|
|
otherSecurityService(114),
|
|
delayedInfo(120),
|
|
keyExpired(121),
|
|
outOfHoursActivity(122),
|
|
-- Start of non-OSI defined values
|
|
operationalCondition(200),
|
|
debugging(201),
|
|
unknown(202),
|
|
inactiveVirtualCircuit(203),
|
|
networkServerIntervention(204)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The probable cause for the alarm which usually
|
|
qualifies the Alarm Type field. Most values are
|
|
OSI-defined; refer to CCITT X.733 and X.736
|
|
(ISO 10164-4 and 10164-7) for a more complete
|
|
description."
|
|
::= { fmSSAlarmInfo 7}
|
|
|
|
ntpIndex OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(8))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An 8-digit code which is an index into an NTP to
|
|
provide more description of the alarm and possible
|
|
actions to take. The first 4 digits indicate a 'group'
|
|
of alarms (belonging to a particular subsystem or
|
|
component, etc.). The last 4 digits are a subindex
|
|
arbitrarily assigned by the application which is
|
|
responsible for them."
|
|
::= { fmSSAlarmInfo 8 }
|
|
|
|
commentData OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..750))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional textual information for the network
|
|
operator to use. It contains only ASCII characters.
|
|
Note: The total number of bytes in commentData,
|
|
operatorData and internalData may not exceed 750 bytes."
|
|
|
|
::= { fmSSAlarmInfo 9}
|
|
|
|
END
|
|
|