snmp_mib_archive/LANOPTICS-HUB-MIB.my 2
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

472 lines
13 KiB
Plaintext

-- *****************************************************************
-- L A N O P T I C S - H U B - M I B . m y
--
-- March 1996, Keith Horil
--
-- Copyright (c) 1996 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
--
-- This mib was developed by LanOptics
LANOPTICS-HUB-MIB DEFINITIONS ::= BEGIN
-- MIB II Extension Definitions for hub management
IMPORTS
OBJECT-TYPE
FROM RFC-1212
enterprises
FROM RFC1155-SMI
DisplayString
FROM RFC1213-MIB;
BITMAP ::= INTEGER
-- bitwise info represented by a single integer
lanOptics OBJECT IDENTIFIER ::= { enterprises 224 }
lanOpticsHub OBJECT IDENTIFIER ::= { lanOptics 1 }
snMaxSlots OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The limit on the total number of slots that the
Hub chassis has."
::= { lanOpticsHub 1 }
snSlotsNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The actual number of slots occupied by the Hub modules ."
::= { lanOpticsHub 2 }
snConfig OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A list of all modules occupying slots in Hub
in accordance with snSlotsNum."
::= { lanOpticsHub 3 }
snLLActiveNMS OBJECT-TYPE
SYNTAX INTEGER {
-- inactive (0),
active (1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"States whether the NMS-431X is active (1) or
inactive (0). For internal use only.
Should not be modified."
::= { lanOpticsHub 4 }
snReset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the management module of the Hub."
::= { lanOpticsHub 5 }
snInternalID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The internal address of the management module (NMS-431X)."
::= { lanOpticsHub 6 }
snDirtyBit OBJECT-TYPE
SYNTAX BITMAP
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Low level description in bits for changes made
in the system."
::= { lanOpticsHub 7 }
snSlotsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnSlotsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of slots entries. The number of entries
is given by the value of snSlotsNum."
::= { lanOpticsHub 8 }
snSlotsEntry OBJECT-TYPE
SYNTAX SnSlotsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A slot entry containing a high and low
level description of the module in the slot."
INDEX { INTEGER }
::= { snSlotsTable 1 }
SnSlotsEntry ::= SEQUENCE {
snCardName
DisplayString,
snCardDescr
DisplayString,
snLLHwRevision
INTEGER,
snLLSwRevision
INTEGER,
snLLControl0
BITMAP,
snLLControl1
BITMAP,
snPollInf
OCTET STRING,
snResetSlot
INTEGER,
snPollInfCode
OCTET STRING,
snAssCode
OCTET STRING
}
snCardName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the card (module) name and type
(IOM,LBM,BKM,NMS). It is set by Management entity .
If not set by the Management entity - will response with HW,SW Rev."
::= { snSlotsEntry 1 }
snCardDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the card media, connectors and
hardware.- not accesible in Low Level. In High Level will be set
by the Management entity (for agents above v5.0)"
::= { snSlotsEntry 2 }
snLLHwRevision OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Low level description of the module's hardware
revision (module type). For internal use only!"
::= { snSlotsEntry 9 }
snLLSwRevision OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Low level description of the module's software
revision (module revision). For internal use only!"
::= { snSlotsEntry 10 }
snLLControl0 OBJECT-TYPE
SYNTAX BITMAP
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Low level description of control actions on the
module. Bit per port. For internal use only!"
::= { snSlotsEntry 14 }
snLLControl1 OBJECT-TYPE
SYNTAX BITMAP
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Low level description of control actions on the
module. Bit per port. For internal use only!."
::= { snSlotsEntry 15 }
snPollInf OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Low level status description of this module
represented by an internal structure. For internal use only."
::= { snSlotsEntry 29 }
snResetSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset this slot (e.g. LBM module, NMS module). If this slot
is the one the Agent occupies, reset the agent (same effect
as snReset variable).
If this is a special slot (0xF), reset the device mapped
to this slot (e.g. the router )."
::= { snSlotsEntry 38 }
snPollInfCode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is set with assembly code for pollInf structure (per slot)"
::= { snSlotsEntry 41 }
snAssCode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is set with assembly code that should be perform immediatly (per slot)"
::= { snSlotsEntry 42 }
snPairAddress OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Low level port address."
::= { lanOpticsHub 9 }
snPairData OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Low level port data. The value of this variable is read/written
from/to the I/O address in snPairAddress variable."
::= { lanOpticsHub 10 }
-- Hub related alerts data
snHubSplitTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnHubSplitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status of each split card."
::= { lanOpticsHub 11 }
snHubSplitEntry OBJECT-TYPE
SYNTAX SnHubSplitEntry
ACCESS not-accessible
STATUS mandatory
INDEX { INTEGER }
::= { snHubSplitTable 1 }
SnHubSplitEntry ::= SEQUENCE {
snHubSplitStatus
INTEGER
}
snHubSplitStatus OBJECT-TYPE
SYNTAX INTEGER {
-- normal (0),
splitted (1),
missing (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable describes the status of this split module."
::= { snHubSplitEntry 1 }
snHubPSTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnHubPSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status of each Power supply."
::= { lanOpticsHub 12 }
snHubPSEntry OBJECT-TYPE
SYNTAX SnHubPSEntry
ACCESS not-accessible
STATUS mandatory
INDEX { INTEGER }
::= { snHubPSTable 1 }
SnHubPSEntry ::= SEQUENCE {
snHubPSStatus
INTEGER
}
snHubPSStatus OBJECT-TYPE
SYNTAX INTEGER {
-- normal (0),
malfunctioning (1),
missing (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable describes the status of this Power Supply."
::= { snHubPSEntry 1 }
snHubFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnHubFanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status of each Fan."
::= { lanOpticsHub 13 }
snHubFanEntry OBJECT-TYPE
SYNTAX SnHubFanEntry
ACCESS not-accessible
STATUS mandatory
INDEX { INTEGER }
::= { snHubFanTable 1 }
SnHubFanEntry ::= SEQUENCE {
snHubFanStatus
INTEGER
}
snHubFanStatus OBJECT-TYPE
SYNTAX INTEGER {
-- normal (0),
malfunctioning (1),
missing (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable describes the status of this Fan."
::= { snHubFanEntry 1 }
snHubSlotsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnHubSlotsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Hub's alerts related information per slot"
::= { lanOpticsHub 14 }
snHubSlotsEntry OBJECT-TYPE
SYNTAX SnHubSlotsEntry
ACCESS not-accessible
STATUS mandatory
INDEX { INTEGER }
::= { snHubSlotsTable 1 }
SnHubSlotsEntry ::= SEQUENCE {
snHubSlotConnected
INTEGER,
snHubSlotFreqError
INTEGER,
snHubSlotRevChanged
INTEGER
}
snHubSlotConnected OBJECT-TYPE
SYNTAX INTEGER {
-- connected (0),
disconnected (1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable signifies that this entire slot
was disconnected or reconnected by a management entity."
::= { snHubSlotsEntry 1 }
snHubSlotFreqError OBJECT-TYPE
SYNTAX INTEGER {
-- no-error (0),
slot-4M (4),
slot-16M (16)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable signifies that this slot frequency
differs from the back-plane's."
::= { snHubSlotsEntry 2 }
snHubSlotRevChanged OBJECT-TYPE
SYNTAX INTEGER {
-- changed (0),
unchanged (1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable signifies that this slot SW revision
has changed."
::= { snHubSlotsEntry 3 }
snCompanionHW OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gives the value of the Hardware and software revision
that is sharing the (PC) bus with the agent, e.g,
a Cisco Router PC-Card. If no hardware exists, the value
should be 0xFF."
::= { lanOpticsHub 15 }
snCompanionReset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send Reset to the companion hardware(cisco router)"
::= { lanOpticsHub 16 }
snCompanionStatus OBJECT-TYPE
SYNTAX BITMAP
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gives the companion status.
For cisco router: Bit0 - Lan Active led(1-on,0-off)
Bit2 - ISDN present bit
Bit3 - O.k. Led(1-on,0-off)"
::= { lanOpticsHub 17 }
snGenPortsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnGenPortsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of all possible I/O ports in address range is 0xC000 - 0xFFFF"
::= { lanOpticsHub 18 }
snGenPortsEntry OBJECT-TYPE
SYNTAX SnGenPortsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An I/O port entry. Each byte of the I/O address is represented
by one index digit; e.g, instance 255.12 is I/O address (port) 0xFF0C."
INDEX { INTEGER, INTEGER }
::= { snGenPortsTable 1 }
SnGenPortsEntry ::= SEQUENCE {
snPortValue
BITMAP
}
snPortValue OBJECT-TYPE
SYNTAX BITMAP
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The I/O port value."
::= { snGenPortsEntry 1 }