FC-MGMT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Integer32, Unsigned32, Counter32, Counter64, transmission
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
TruthValue, TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
ifIndex FROM IF-MIB
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
|
|
|
|
fcMgmtMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200504260000Z" -- 26 April 2005
|
|
ORGANIZATION "IETF IPS (IP-Storage) Working Group"
|
|
CONTACT-INFO
|
|
" Keith McCloghrie
|
|
Cisco Systems, Inc.
|
|
Tel: +1 408 526-5260
|
|
E-mail: kzm@cisco.com
|
|
Postal: 170 West Tasman Drive
|
|
San Jose, CA USA 95134
|
|
"
|
|
DESCRIPTION
|
|
"This module defines management information specific to
|
|
Fibre Channel-attached devices.
|
|
|
|
Copyright (C) The Internet Society (2005). This version
|
|
of this MIB module is part of RFC 4044; see the RFC
|
|
itself for full legal notices."
|
|
REVISION "200504260000Z" -- 26 April 2005
|
|
DESCRIPTION
|
|
"Initial version of the Fibre Channel Mgmt MIB module."
|
|
::= { transmission 56 }
|
|
|
|
fcmgmtObjects OBJECT IDENTIFIER ::= { fcMgmtMIB 1 }
|
|
fcmgmtNotifications OBJECT IDENTIFIER ::= { fcMgmtMIB 2 }
|
|
fcmgmtNotifPrefix OBJECT IDENTIFIER ::= { fcmgmtNotifications 0 }
|
|
fcmgmtConformance OBJECT IDENTIFIER ::= { fcMgmtMIB 3 }
|
|
|
|
--********************************
|
|
-- Textual Conventions
|
|
--
|
|
|
|
FcNameIdOrZero ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The World Wide Name (WWN) associated with a Fibre Channel
|
|
(FC) entity. WWNs were initially defined as 64-bits in
|
|
length. The latest definition (for future use) is 128-bits
|
|
long. The zero-length string value is used in
|
|
circumstances in which the WWN is unassigned/unknown."
|
|
SYNTAX OCTET STRING (SIZE(0 | 8 | 16))
|
|
|
|
FcAddressIdOrZero ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Fibre Channel Address ID, a 24-bit value unique within
|
|
the address space of a Fabric. The zero-length string value
|
|
is used in circumstances in which the WWN is
|
|
unassigned/unknown."
|
|
SYNTAX OCTET STRING (SIZE(0 | 3))
|
|
|
|
FcDomainIdOrZero ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Domain Id (of an FC switch), or zero if the no Domain
|
|
Id has been assigned."
|
|
SYNTAX Integer32 (0..239)
|
|
|
|
FcPortType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of a Fibre Channel port, as indicated by the use
|
|
of the appropriate value assigned by IANA."
|
|
REFERENCE
|
|
"The IANA-maintained registry for
|
|
Fibre Channel port types (http://www.iana.org/)."
|
|
SYNTAX Unsigned32
|
|
|
|
FcClasses ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of Fibre Channel classes of service."
|
|
REFERENCE
|
|
"Classes of service are described in FC-FS Section 13."
|
|
SYNTAX BITS { classF(0), class1(1), class2(2), class3(3),
|
|
class4(4), class5(5), class6(6) }
|
|
|
|
FcBbCredit ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The buffer-to-buffer credit of an FC port."
|
|
SYNTAX Integer32 (0..32767)
|
|
|
|
FcBbCreditModel ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The buffer-to-buffer credit model of an Fx_Port."
|
|
SYNTAX INTEGER { regular(1), alternate (2) }
|
|
|
|
FcDataFieldSize ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Receive Data Field Size associated with an FC port."
|
|
SYNTAX Integer32 (128..2112)
|
|
|
|
FcUnitFunctions ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of functions that a Fibre Channel Interconnect
|
|
Element or Platform might perform. A value with no bits set
|
|
indicates the function(s) are unknown. The individual bits
|
|
have the following meanings:
|
|
|
|
other - none of the following.
|
|
|
|
hub - a device that interconnects L_Ports, but does not
|
|
operate as an FL_Port.
|
|
|
|
switch - a fabric element conforming to the Fibre Channel
|
|
switch fabric set of standards (e.g., [FC-SW-3]).
|
|
|
|
bridge - a device that encapsulates Fibre Channel frames
|
|
within another protocol (e.g., [FC-BB], FC-BB-2).
|
|
|
|
gateway - a device that converts an FC-4 to another protocol
|
|
(e.g., FCP to iSCSI).
|
|
|
|
host - a computer system that provides end users with
|
|
services such as computation and storage access.
|
|
|
|
storageSubsys - an integrated collection of storage
|
|
controllers, storage devices, and necessary software that
|
|
provides storage services to one or more hosts.
|
|
|
|
storageAccessDev - a device that provides storage management
|
|
and access for heterogeneous hosts and heterogeneous devices
|
|
(e.g., medium changer).
|
|
|
|
nas - a device that connects to a network and provides file
|
|
access services.
|
|
|
|
wdmux - a device that modulates/demodulates each of several
|
|
data streams (e.g., Fibre Channel protocol data streams)
|
|
onto/from a different part of the light spectrum in an
|
|
optical fiber.
|
|
|
|
storageDevice - a disk/tape/etc. device (without the
|
|
controller and/or software required for it to be a
|
|
'storageSubsys')."
|
|
SYNTAX BITS {
|
|
other(0), -- none of the following
|
|
hub(1),
|
|
switch(2),
|
|
|
|
bridge(3),
|
|
gateway(4),
|
|
host(5),
|
|
storageSubsys(6),
|
|
storageAccessDev(7),
|
|
nas(8),
|
|
wdmux(9),
|
|
storageDevice(10)
|
|
}
|
|
|
|
--********************************
|
|
-- MIB object definitions
|
|
--
|
|
|
|
fcmInstanceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about the local Fibre Channel management
|
|
instances."
|
|
::= { fcmgmtObjects 1 }
|
|
|
|
fcmInstanceEntry OBJECT-TYPE
|
|
SYNTAX FcmInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of attributes for a particular local Fibre Channel
|
|
management instance."
|
|
INDEX { fcmInstanceIndex }
|
|
::= { fcmInstanceTable 1 }
|
|
|
|
FcmInstanceEntry ::=
|
|
SEQUENCE {
|
|
fcmInstanceIndex Unsigned32,
|
|
fcmInstanceWwn FcNameIdOrZero,
|
|
fcmInstanceFunctions FcUnitFunctions,
|
|
fcmInstancePhysicalIndex Integer32,
|
|
fcmInstanceSoftwareIndex Integer32,
|
|
fcmInstanceStatus INTEGER,
|
|
fcmInstanceTextName SnmpAdminString,
|
|
fcmInstanceDescr SnmpAdminString,
|
|
fcmInstanceFabricId FcNameIdOrZero
|
|
}
|
|
|
|
fcmInstanceIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary integer value that uniquely identifies this
|
|
instance amongst all local Fibre Channel management
|
|
instances.
|
|
|
|
It is mandatory to keep this value constant between restarts
|
|
of the agent, and to make every possible effort to keep it
|
|
constant across restarts (but note, it is unrealistic to
|
|
expect it to remain constant across all re-configurations of
|
|
the local system, e.g., across the replacement of all non-
|
|
volatile storage)."
|
|
::= { fcmInstanceEntry 1 }
|
|
|
|
fcmInstanceWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the instance has one (or more) WWN(s), then this object
|
|
contains that (or one of those) WWN(s).
|
|
|
|
If the instance does not have a WWN associated with it, then
|
|
this object contains the zero-length string."
|
|
::= { fcmInstanceEntry 2 }
|
|
|
|
fcmInstanceFunctions OBJECT-TYPE
|
|
SYNTAX FcUnitFunctions
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One (or more) Fibre Channel unit functions being performed
|
|
by this instance."
|
|
::= { fcmInstanceEntry 3 }
|
|
|
|
fcmInstancePhysicalIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this management instance corresponds to a physical
|
|
component (or to a hierarchy of physical components)
|
|
identified by the Entity-MIB, then this object's value is
|
|
the value of the entPhysicalIndex of that component (or of
|
|
the component at the root of that hierarchy). If there is
|
|
|
|
no correspondence to a physical component (or no component
|
|
that has an entPhysicalIndex value), then the value of this
|
|
object is zero."
|
|
REFERENCE
|
|
"entPhysicalIndex is defined in the Entity MIB, RFC 2737."
|
|
::= { fcmInstanceEntry 4 }
|
|
|
|
fcmInstanceSoftwareIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this management instance corresponds to an installed
|
|
software module identified in the Host Resources MIB, then
|
|
this object's value is the value of the hrSWInstalledIndex
|
|
of that module. If there is no correspondence to an
|
|
installed software module (or no module that has a
|
|
hrSWInstalledIndex value), then the value of this object is
|
|
zero."
|
|
REFERENCE
|
|
"hrSWInstalledIndex is defined in the Host Resources MIB,
|
|
RFC 2790"
|
|
::= { fcmInstanceEntry 5 }
|
|
|
|
fcmInstanceStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
ok(2), -- able to operate correctly
|
|
warning(3), -- needs attention
|
|
failed(4) -- something has failed
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overall status of the Fibre Channel entity/entities managed
|
|
by this management instance. The value should reflect the
|
|
most serious status of such entities."
|
|
::= { fcmInstanceEntry 6 }
|
|
|
|
fcmInstanceTextName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..79))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual name for this management instance and the Fibre
|
|
Channel entity/entities that it is managing."
|
|
::= { fcmInstanceEntry 7 }
|
|
|
|
fcmInstanceDescr OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description of this management instance and the
|
|
Fibre Channel entity/entities that it is managing."
|
|
::= { fcmInstanceEntry 8 }
|
|
|
|
fcmInstanceFabricId OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The globally unique Fabric Identifier that identifies the
|
|
fabric to which the Fibre Channel entity/entities managed by
|
|
this management instance are connected, or, of which they
|
|
are a part. This is typically the Node WWN of the principal
|
|
switch of a Fibre Channel fabric. The zero-length string
|
|
indicates that the fabric identifier is unknown (or not
|
|
applicable).
|
|
|
|
In the event that the Fibre Channel entity/entities managed
|
|
by this management instance is/are connected to multiple
|
|
fabrics, then this object records the first (known) one."
|
|
::= { fcmInstanceEntry 9 }
|
|
|
|
--********************************
|
|
-- The Fibre Channel Switch Table
|
|
--
|
|
|
|
fcmSwitchTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmSwitchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of information about Fibre Channel switches that
|
|
are managed by Fibre Channel management instances. Each
|
|
Fibre Channel management instance can manage one or more
|
|
Fibre Channel switches."
|
|
::= { fcmgmtObjects 2 }
|
|
|
|
fcmSwitchEntry OBJECT-TYPE
|
|
SYNTAX FcmSwitchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about a particular Fibre Channel switch that is
|
|
|
|
managed by the management instance given by
|
|
fcmInstanceIndex."
|
|
INDEX { fcmInstanceIndex, fcmSwitchIndex }
|
|
::= { fcmSwitchTable 1 }
|
|
|
|
FcmSwitchEntry ::=
|
|
SEQUENCE {
|
|
fcmSwitchIndex Unsigned32,
|
|
fcmSwitchDomainId FcDomainIdOrZero,
|
|
fcmSwitchPrincipal TruthValue,
|
|
fcmSwitchWWN FcNameIdOrZero
|
|
}
|
|
|
|
fcmSwitchIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary integer that uniquely identifies a Fibre
|
|
Channel switch amongst those managed by one Fibre Channel
|
|
management instance.
|
|
|
|
It is mandatory to keep this value constant between restarts
|
|
of the agent, and to make every possible effort to keep it
|
|
constant across restarts."
|
|
::= { fcmSwitchEntry 1 }
|
|
|
|
fcmSwitchDomainId OBJECT-TYPE
|
|
SYNTAX FcDomainIdOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Domain Id of this switch. A value of zero indicates
|
|
that a switch has not (yet) been assigned a Domain Id."
|
|
::= { fcmSwitchEntry 2 }
|
|
|
|
fcmSwitchPrincipal OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of whether this switch is the principal
|
|
switch within its fabric."
|
|
::= { fcmSwitchEntry 3 }
|
|
|
|
fcmSwitchWWN OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The World Wide Name of this switch."
|
|
::= { fcmSwitchEntry 4 }
|
|
|
|
--********************************
|
|
-- The Fibre Channel Port Table
|
|
--
|
|
|
|
fcmPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about Fibre Channel ports. Each Fibre Channel
|
|
port is represented by one entry in the IF-MIB's ifTable."
|
|
REFERENCE
|
|
"RFC 2863, The Interfaces Group MIB, June 2000."
|
|
::= { fcmgmtObjects 3 }
|
|
|
|
fcmPortEntry OBJECT-TYPE
|
|
SYNTAX FcmPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry contains information about a specific port."
|
|
INDEX { ifIndex }
|
|
::= { fcmPortTable 1 }
|
|
|
|
FcmPortEntry ::=
|
|
SEQUENCE {
|
|
fcmPortInstanceIndex Unsigned32,
|
|
fcmPortWwn FcNameIdOrZero,
|
|
fcmPortNodeWwn FcNameIdOrZero,
|
|
fcmPortAdminType FcPortType,
|
|
fcmPortOperType FcPortType,
|
|
fcmPortFcCapClass FcClasses,
|
|
fcmPortFcOperClass FcClasses,
|
|
fcmPortTransmitterType INTEGER,
|
|
fcmPortConnectorType INTEGER,
|
|
fcmPortSerialNumber SnmpAdminString,
|
|
fcmPortPhysicalNumber Unsigned32,
|
|
fcmPortAdminSpeed INTEGER,
|
|
fcmPortCapProtocols BITS,
|
|
fcmPortOperProtocols BITS
|
|
|
|
}
|
|
|
|
fcmPortInstanceIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of fcmInstanceIndex by which the Fibre Channel
|
|
management instance, which manages this port, is identified
|
|
in the fcmInstanceTable."
|
|
::= { fcmPortEntry 1 }
|
|
|
|
fcmPortWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The World Wide Name of the port, or the zero-length string
|
|
if the port does not have a WWN."
|
|
::= { fcmPortEntry 2 }
|
|
|
|
fcmPortNodeWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The World Wide Name of the Node that contains this port, or
|
|
the zero-length string if the port does not have a node
|
|
WWN."
|
|
::= { fcmPortEntry 3 }
|
|
|
|
fcmPortAdminType OBJECT-TYPE
|
|
SYNTAX FcPortType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administratively desired type of this port."
|
|
::= { fcmPortEntry 4 }
|
|
|
|
fcmPortOperType OBJECT-TYPE
|
|
SYNTAX FcPortType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational type of this port."
|
|
::= { fcmPortEntry 5 }
|
|
|
|
fcmPortFcCapClass OBJECT-TYPE
|
|
SYNTAX FcClasses
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The classes of service capability of this port."
|
|
::= { fcmPortEntry 6 }
|
|
|
|
fcmPortFcOperClass OBJECT-TYPE
|
|
SYNTAX FcClasses
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The classes of service that are currently operational on
|
|
this port. For an FL_Port, this is the union of the classes
|
|
being supported across all attached NL_Ports."
|
|
::= { fcmPortEntry 7 }
|
|
|
|
fcmPortTransmitterType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
shortwave850nm(3),
|
|
longwave1550nm(4),
|
|
longwave1310nm(5),
|
|
electrical(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The technology of the port transceiver."
|
|
REFERENCE
|
|
"FC-GS-3, section 6.1.2.2.3"
|
|
::= { fcmPortEntry 8 }
|
|
|
|
fcmPortConnectorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
gbic(3),
|
|
embedded(4),
|
|
glm(5),
|
|
gbicSerialId(6),
|
|
gbicNoSerialId(7),
|
|
sfpSerialId(8),
|
|
sfpNoSerialId(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The module type of the port connector. This object refers
|
|
to the hardware implementation of the port. It will be
|
|
'embedded' if the hardware equivalent to Gigabit interface
|
|
card (GBIC) is part of the line card and is unremovable. It
|
|
will be 'glm' if it's a gigabit link module (GLM). It will
|
|
be 'gbicSerialId' if the GBIC serial id can be read, else it
|
|
will be 'gbicNoSerialId'. It will be 'sfpSerialId' if the
|
|
small form factor (SFP) pluggable GBICs serial id can be
|
|
read, else it will be 'sfpNoSerialId'."
|
|
REFERENCE
|
|
"FC-GS-3, section 6.1.2.2.4"
|
|
::= { fcmPortEntry 9 }
|
|
|
|
fcmPortSerialNumber OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number associated with the port (e.g., for a
|
|
GBIC). If not applicable, the object's value is a zero-
|
|
length string."
|
|
REFERENCE
|
|
"FC-GS-3, section 6.1.2.2.4"
|
|
::= { fcmPortEntry 10 }
|
|
|
|
fcmPortPhysicalNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the port's 'Physical Port Number' as defined by
|
|
GS-3."
|
|
REFERENCE
|
|
"FC-GS-3, section 6.1.2.2.5"
|
|
::= { fcmPortEntry 11 }
|
|
|
|
fcmPortAdminSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(1),
|
|
eighthGbs(2), -- 125Mbs
|
|
quarterGbs(3), -- 250Mbs
|
|
halfGbs(4), -- 500Mbs
|
|
oneGbs(5), -- 1Gbs
|
|
twoGbs(6), -- 2Gbs
|
|
fourGbs(7), -- 4Gbs
|
|
tenGbs(8) -- 10Gbs
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The speed of the interface:
|
|
|
|
'auto' - auto-negotiation
|
|
'tenGbs' - 10Gbs
|
|
'fourGbs' - 4Gbs
|
|
'twoGbs' - 2Gbs
|
|
'oneGbs' - 1Gbs
|
|
'halfGbs' - 500Mbs
|
|
'quarterGbs' - 250Mbs
|
|
'eighthGbs' - 125Mbs"
|
|
::= { fcmPortEntry 12 }
|
|
|
|
fcmPortCapProtocols OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
unknown(0),
|
|
loop(1),
|
|
fabric(2),
|
|
scsi(3),
|
|
tcpIp(4),
|
|
vi(5),
|
|
ficon(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit mask specifying the higher level protocols that are
|
|
capable of running over this port. Note that for generic
|
|
Fx_Ports, E_Ports, and B_Ports, this object will indicate
|
|
all protocols."
|
|
::= { fcmPortEntry 13 }
|
|
|
|
fcmPortOperProtocols OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
unknown(0),
|
|
loop(1),
|
|
fabric(2),
|
|
scsi(3),
|
|
tcpIp(4),
|
|
vi(5),
|
|
ficon(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"A bit mask specifying the higher level protocols that are
|
|
currently operational on this port. For Fx_Ports, E_Ports,
|
|
and B_Ports, this object will typically have the value
|
|
'unknown'."
|
|
::= { fcmPortEntry 14 }
|
|
|
|
--********************************
|
|
-- Port Statistics
|
|
--
|
|
|
|
fcmPortStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmPortStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of statistics for Fibre Channel ports."
|
|
::= { fcmgmtObjects 4 }
|
|
|
|
fcmPortStatsEntry OBJECT-TYPE
|
|
SYNTAX FcmPortStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing statistics for a Fibre Channel port.
|
|
If any counter in this table suffers a discontinuity, the
|
|
value of ifCounterDiscontinuityTime (defined in the IF-MIB)
|
|
must be updated."
|
|
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
|
|
AUGMENTS { fcmPortEntry }
|
|
::= { fcmPortStatsTable 1 }
|
|
|
|
FcmPortStatsEntry ::=
|
|
SEQUENCE {
|
|
fcmPortBBCreditZeros Counter64,
|
|
fcmPortFullInputBuffers Counter64,
|
|
fcmPortClass2RxFrames Counter64,
|
|
fcmPortClass2RxOctets Counter64,
|
|
fcmPortClass2TxFrames Counter64,
|
|
fcmPortClass2TxOctets Counter64,
|
|
fcmPortClass2Discards Counter64,
|
|
fcmPortClass2RxFbsyFrames Counter64,
|
|
fcmPortClass2RxPbsyFrames Counter64,
|
|
fcmPortClass2RxFrjtFrames Counter64,
|
|
fcmPortClass2RxPrjtFrames Counter64,
|
|
fcmPortClass2TxFbsyFrames Counter64,
|
|
fcmPortClass2TxPbsyFrames Counter64,
|
|
fcmPortClass2TxFrjtFrames Counter64,
|
|
fcmPortClass2TxPrjtFrames Counter64,
|
|
|
|
fcmPortClass3RxFrames Counter64,
|
|
fcmPortClass3RxOctets Counter64,
|
|
fcmPortClass3TxFrames Counter64,
|
|
fcmPortClass3TxOctets Counter64,
|
|
fcmPortClass3Discards Counter64,
|
|
fcmPortClassFRxFrames Counter32,
|
|
fcmPortClassFRxOctets Counter32,
|
|
fcmPortClassFTxFrames Counter32,
|
|
fcmPortClassFTxOctets Counter32,
|
|
fcmPortClassFDiscards Counter32
|
|
}
|
|
|
|
fcmPortBBCreditZeros OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of transitions in/out of the buffer-to-buffer
|
|
credit zero state. The other side is not providing any
|
|
credit."
|
|
::= { fcmPortStatsEntry 1 }
|
|
|
|
fcmPortFullInputBuffers OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of occurrences when all input buffers of a port
|
|
were full and outbound buffer-to-buffer credit transitioned
|
|
to zero, i.e., there became no credit to provide to other
|
|
side."
|
|
::= { fcmPortStatsEntry 2 }
|
|
|
|
fcmPortClass2RxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 2 frames received at this port."
|
|
::= { fcmPortStatsEntry 3 }
|
|
|
|
fcmPortClass2RxOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class 2 frames received
|
|
at this port."
|
|
|
|
::= { fcmPortStatsEntry 4 }
|
|
|
|
fcmPortClass2TxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 2 frames transmitted out of this port."
|
|
::= { fcmPortStatsEntry 5 }
|
|
|
|
fcmPortClass2TxOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class 2 frames
|
|
transmitted out of this port."
|
|
::= { fcmPortStatsEntry 6 }
|
|
|
|
fcmPortClass2Discards OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 2 frames that were discarded upon
|
|
reception at this port."
|
|
::= { fcmPortStatsEntry 7 }
|
|
|
|
fcmPortClass2RxFbsyFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that F_BSY was returned to this port as
|
|
a result of a Class 2 frame that could not be delivered to
|
|
the other end of the link. This can occur when either the
|
|
fabric or the destination port is temporarily busy. Note
|
|
that this counter will never increment for an F_Port."
|
|
::= { fcmPortStatsEntry 8 }
|
|
|
|
fcmPortClass2RxPbsyFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that P_BSY was returned to this port as
|
|
a result of a Class 2 frame that could not be delivered to
|
|
the other end of the link. This can occur when the
|
|
|
|
destination port is temporarily busy."
|
|
::= { fcmPortStatsEntry 9 }
|
|
|
|
fcmPortClass2RxFrjtFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that F_RJT was returned to this port as
|
|
a result of a Class 2 frame that was rejected by the fabric.
|
|
Note that this counter will never increment for an F_Port."
|
|
::= { fcmPortStatsEntry 10 }
|
|
|
|
fcmPortClass2RxPrjtFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that P_RJT was returned to this port as
|
|
a result of a Class 2 frame that was rejected at the
|
|
destination N_Port."
|
|
::= { fcmPortStatsEntry 11 }
|
|
|
|
fcmPortClass2TxFbsyFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that F_BSY was generated by this port
|
|
as a result of a Class 2 frame that could not be delivered
|
|
because either the Fabric or the destination port was
|
|
temporarily busy. Note that this counter will never
|
|
increment for an N_Port."
|
|
::= { fcmPortStatsEntry 12 }
|
|
|
|
fcmPortClass2TxPbsyFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that P_BSY was generated by this port
|
|
as a result of a Class 2 frame that could not be delivered
|
|
because the destination port was temporarily busy. Note
|
|
that this counter will never increment for an F_Port."
|
|
::= { fcmPortStatsEntry 13 }
|
|
|
|
fcmPortClass2TxFrjtFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that F_RJT was generated by this port
|
|
as a result of a Class 2 frame being rejected by the fabric.
|
|
Note that this counter will never increment for an N_Port."
|
|
::= { fcmPortStatsEntry 14 }
|
|
|
|
fcmPortClass2TxPrjtFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that P_RJT was generated by this port
|
|
as a result of a Class 2 frame being rejected at the
|
|
destination N_Port. Note that this counter will never
|
|
increment for an F_Port."
|
|
::= { fcmPortStatsEntry 15 }
|
|
|
|
fcmPortClass3RxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 3 frames received at this port."
|
|
::= { fcmPortStatsEntry 16 }
|
|
|
|
fcmPortClass3RxOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class 3 frames received
|
|
at this port."
|
|
::= { fcmPortStatsEntry 17 }
|
|
|
|
fcmPortClass3TxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 3 frames transmitted out of this port."
|
|
::= { fcmPortStatsEntry 18 }
|
|
|
|
fcmPortClass3TxOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class 3 frames
|
|
transmitted out of this port."
|
|
::= { fcmPortStatsEntry 19 }
|
|
|
|
fcmPortClass3Discards OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 3 frames that were discarded upon
|
|
reception at this port."
|
|
::= { fcmPortStatsEntry 20 }
|
|
|
|
fcmPortClassFRxFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class F frames received at this port."
|
|
::= { fcmPortStatsEntry 21 }
|
|
|
|
fcmPortClassFRxOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class F frames received
|
|
at this port."
|
|
::= { fcmPortStatsEntry 22 }
|
|
|
|
fcmPortClassFTxFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class F frames transmitted out of this port."
|
|
::= { fcmPortStatsEntry 23 }
|
|
|
|
fcmPortClassFTxOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class F frames
|
|
transmitted out of this port."
|
|
::= { fcmPortStatsEntry 24 }
|
|
|
|
fcmPortClassFDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class F frames that were discarded upon
|
|
reception at this port."
|
|
::= { fcmPortStatsEntry 25 }
|
|
|
|
--********************************
|
|
-- Port Low-capacity Statistics
|
|
--
|
|
-- these are Counter32 "low-capacity" counters for systems
|
|
-- that do not support Counter64's
|
|
|
|
fcmPortLcStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmPortLcStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Counter32-based statistics for systems that do
|
|
not support Counter64."
|
|
::= { fcmgmtObjects 5 }
|
|
|
|
fcmPortLcStatsEntry OBJECT-TYPE
|
|
SYNTAX FcmPortLcStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing low-capacity (i.e., based on Counter32)
|
|
statistics for a Fibre Channel port. If any counter in this
|
|
table suffers a discontinuity, the value of
|
|
ifCounterDiscontinuityTime (defined in the IF-MIB) must be
|
|
updated."
|
|
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
|
|
AUGMENTS { fcmPortEntry }
|
|
::= { fcmPortLcStatsTable 1 }
|
|
|
|
FcmPortLcStatsEntry ::=
|
|
SEQUENCE {
|
|
fcmPortLcBBCreditZeros Counter32,
|
|
fcmPortLcFullInputBuffers Counter32,
|
|
fcmPortLcClass2RxFrames Counter32,
|
|
fcmPortLcClass2RxOctets Counter32,
|
|
fcmPortLcClass2TxFrames Counter32,
|
|
fcmPortLcClass2TxOctets Counter32,
|
|
fcmPortLcClass2Discards Counter32,
|
|
fcmPortLcClass2RxFbsyFrames Counter32,
|
|
fcmPortLcClass2RxPbsyFrames Counter32,
|
|
fcmPortLcClass2RxFrjtFrames Counter32,
|
|
fcmPortLcClass2RxPrjtFrames Counter32,
|
|
fcmPortLcClass2TxFbsyFrames Counter32,
|
|
fcmPortLcClass2TxPbsyFrames Counter32,
|
|
fcmPortLcClass2TxFrjtFrames Counter32,
|
|
fcmPortLcClass2TxPrjtFrames Counter32,
|
|
fcmPortLcClass3RxFrames Counter32,
|
|
fcmPortLcClass3RxOctets Counter32,
|
|
fcmPortLcClass3TxFrames Counter32,
|
|
fcmPortLcClass3TxOctets Counter32,
|
|
fcmPortLcClass3Discards Counter32
|
|
}
|
|
|
|
fcmPortLcBBCreditZeros OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of transitions in/out of the buffer-to-buffer
|
|
credit zero state. The other side is not providing any
|
|
credit."
|
|
::= { fcmPortLcStatsEntry 1 }
|
|
|
|
fcmPortLcFullInputBuffers OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of occurrences when all input buffers of a port
|
|
were full and outbound buffer-to-buffer credit transitioned
|
|
to zero, i.e., there became no credit to provide to other
|
|
side."
|
|
::= { fcmPortLcStatsEntry 2 }
|
|
|
|
fcmPortLcClass2RxFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 2 frames received at this port."
|
|
::= { fcmPortLcStatsEntry 3 }
|
|
|
|
fcmPortLcClass2RxOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class 2 frames received
|
|
at this port."
|
|
::= { fcmPortLcStatsEntry 4 }
|
|
|
|
fcmPortLcClass2TxFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 2 frames transmitted out of this port."
|
|
::= { fcmPortLcStatsEntry 5 }
|
|
|
|
fcmPortLcClass2TxOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class 2 frames
|
|
transmitted out of this port."
|
|
::= { fcmPortLcStatsEntry 6 }
|
|
|
|
fcmPortLcClass2Discards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 2 frames that were discarded upon
|
|
reception at this port."
|
|
::= { fcmPortLcStatsEntry 7 }
|
|
|
|
fcmPortLcClass2RxFbsyFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that F_BSY was returned to this port as
|
|
a result of a Class 2 frame that could not be delivered to
|
|
the other end of the link. This can occur when either the
|
|
fabric or the destination port is temporarily busy. Note
|
|
that this counter will never increment for an F_Port."
|
|
::= { fcmPortLcStatsEntry 8 }
|
|
|
|
fcmPortLcClass2RxPbsyFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that P_BSY was returned to this port as
|
|
a result of a Class 2 frame that could not be delivered to
|
|
the other end of the link. This can occur when the
|
|
destination port is temporarily busy."
|
|
::= { fcmPortLcStatsEntry 9 }
|
|
|
|
fcmPortLcClass2RxFrjtFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that F_RJT was returned to this port as
|
|
a result of a Class 2 frame that was rejected by the fabric.
|
|
Note that this counter will never increment for an F_Port."
|
|
::= { fcmPortLcStatsEntry 10 }
|
|
|
|
fcmPortLcClass2RxPrjtFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that P_RJT was returned to this port as
|
|
a result of a Class 2 frame that was rejected at the
|
|
destination N_Port."
|
|
::= { fcmPortLcStatsEntry 11 }
|
|
|
|
fcmPortLcClass2TxFbsyFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that F_BSY was generated by this port
|
|
as a result of a Class 2 frame that could not be delivered
|
|
because either the Fabric or the destination port was
|
|
temporarily busy. Note that this counter will never
|
|
increment for an N_Port."
|
|
::= { fcmPortLcStatsEntry 12 }
|
|
|
|
fcmPortLcClass2TxPbsyFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that P_BSY was generated by this port
|
|
as a result of a Class 2 frame that could not be delivered
|
|
because the destination port was temporarily busy. Note
|
|
that this counter will never increment for an F_Port."
|
|
::= { fcmPortLcStatsEntry 13 }
|
|
|
|
fcmPortLcClass2TxFrjtFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that F_RJT was generated by this port
|
|
as a result of a Class 2 frame being rejected by the fabric.
|
|
Note that this counter will never increment for an N_Port."
|
|
::= { fcmPortLcStatsEntry 14 }
|
|
|
|
fcmPortLcClass2TxPrjtFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that P_RJT was generated by this port
|
|
as a result of a Class 2 frame being rejected at the
|
|
destination N_Port. Note that this counter will never
|
|
increment for an F_Port."
|
|
::= { fcmPortLcStatsEntry 15 }
|
|
|
|
fcmPortLcClass3RxFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 3 frames received at this port."
|
|
::= { fcmPortLcStatsEntry 16 }
|
|
|
|
fcmPortLcClass3RxOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class 3 frames received
|
|
at this port."
|
|
::= { fcmPortLcStatsEntry 17 }
|
|
|
|
fcmPortLcClass3TxFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 3 frames transmitted out of this port."
|
|
::= { fcmPortLcStatsEntry 18 }
|
|
|
|
fcmPortLcClass3TxOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets contained in Class 3 frames
|
|
transmitted out of this port."
|
|
::= { fcmPortLcStatsEntry 19 }
|
|
|
|
fcmPortLcClass3Discards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Class 3 frames that were discarded upon
|
|
reception at this port."
|
|
::= { fcmPortLcStatsEntry 20 }
|
|
|
|
--********************************
|
|
-- Port Error Counters
|
|
--
|
|
|
|
fcmPortErrorsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmPortErrorsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error counters for Fibre Channel ports."
|
|
::= { fcmgmtObjects 6 }
|
|
|
|
fcmPortErrorsEntry OBJECT-TYPE
|
|
SYNTAX FcmPortErrorsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error counters for a Fibre Channel port. If any counter in
|
|
this table suffers a discontinuity, the value of
|
|
ifCounterDiscontinuityTime (defined in the IF-MIB) must be
|
|
updated."
|
|
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
|
|
AUGMENTS { fcmPortEntry }
|
|
::= { fcmPortErrorsTable 1 }
|
|
|
|
FcmPortErrorsEntry ::=
|
|
SEQUENCE {
|
|
fcmPortRxLinkResets Counter32,
|
|
fcmPortTxLinkResets Counter32,
|
|
fcmPortLinkResets Counter32,
|
|
fcmPortRxOfflineSequences Counter32,
|
|
fcmPortTxOfflineSequences Counter32,
|
|
fcmPortLinkFailures Counter32,
|
|
fcmPortLossofSynchs Counter32,
|
|
fcmPortLossofSignals Counter32,
|
|
fcmPortPrimSeqProtocolErrors Counter32,
|
|
fcmPortInvalidTxWords Counter32,
|
|
fcmPortInvalidCRCs Counter32,
|
|
fcmPortInvalidOrderedSets Counter32,
|
|
fcmPortFrameTooLongs Counter32,
|
|
fcmPortTruncatedFrames Counter32,
|
|
fcmPortAddressErrors Counter32,
|
|
fcmPortDelimiterErrors Counter32,
|
|
fcmPortEncodingDisparityErrors Counter32,
|
|
fcmPortOtherErrors Counter32
|
|
}
|
|
|
|
fcmPortRxLinkResets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Link Reset (LR) Primitive Sequences
|
|
received."
|
|
::= { fcmPortErrorsEntry 1 }
|
|
|
|
fcmPortTxLinkResets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Link Reset (LR) Primitive Sequences
|
|
transmitted."
|
|
::= { fcmPortErrorsEntry 2 }
|
|
|
|
fcmPortLinkResets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the reset link protocol was initiated
|
|
on this port. This includes the number of Loop
|
|
Initialization Primitive (LIP) events on an arbitrated loop
|
|
port."
|
|
::= { fcmPortErrorsEntry 3 }
|
|
|
|
fcmPortRxOfflineSequences OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Offline (OLS) Primitive Sequences received at
|
|
this port."
|
|
::= { fcmPortErrorsEntry 4 }
|
|
|
|
fcmPortTxOfflineSequences OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Offline (OLS) Primitive Sequences transmitted
|
|
by this port."
|
|
::= { fcmPortErrorsEntry 5 }
|
|
|
|
fcmPortLinkFailures OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of link failures. This count is part of FC-PH's
|
|
Link Error Status Block (LESB)."
|
|
REFERENCE
|
|
"FC-PH, rev 4.3, 1 June 1994, section 29.8 [FC-PH]."
|
|
::= { fcmPortErrorsEntry 6 }
|
|
|
|
fcmPortLossofSynchs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of instances of synchronization loss detected at
|
|
this port. This count is part of FC-PH's Link Error Status
|
|
Block (LESB)."
|
|
REFERENCE
|
|
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
|
|
::= { fcmPortErrorsEntry 7 }
|
|
|
|
fcmPortLossofSignals OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of instances of signal loss detected at this
|
|
port. This count is part of FC-PH's Link Error Status Block
|
|
(LESB)."
|
|
REFERENCE
|
|
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
|
|
::= { fcmPortErrorsEntry 8 }
|
|
|
|
fcmPortPrimSeqProtocolErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of primitive sequence protocol errors detected
|
|
at this port. This count is part of FC-PH's Link Error
|
|
Status Block (LESB)."
|
|
REFERENCE
|
|
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
|
|
::= { fcmPortErrorsEntry 9 }
|
|
|
|
fcmPortInvalidTxWords OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of invalid transmission words received at this
|
|
port. This count is part of FC-PH's Link Error Status Block
|
|
(LESB)."
|
|
REFERENCE
|
|
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
|
|
::= { fcmPortErrorsEntry 10 }
|
|
|
|
fcmPortInvalidCRCs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames received with an invalid CRC. This
|
|
count is part of FC-PH's Link Error Status Block (LESB)."
|
|
REFERENCE
|
|
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
|
|
::= { fcmPortErrorsEntry 11 }
|
|
|
|
fcmPortInvalidOrderedSets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of invalid ordered sets received at this port."
|
|
::= { fcmPortErrorsEntry 12 }
|
|
|
|
fcmPortFrameTooLongs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames received at this port for which the
|
|
frame length was greater than what was agreed to in
|
|
FLOGI/PLOGI. This could be caused by losing the end of
|
|
frame delimiter."
|
|
::= { fcmPortErrorsEntry 13 }
|
|
|
|
fcmPortTruncatedFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames received at this port for which the
|
|
|
|
frame length was less than the minimum indicated by the
|
|
frame header - normally 24 bytes, but it could be more if
|
|
the DFCTL field indicates an optional header should have
|
|
been present."
|
|
::= { fcmPortErrorsEntry 14 }
|
|
|
|
fcmPortAddressErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames received with unknown addressing; for
|
|
example, an unknown SID or DID."
|
|
::= { fcmPortErrorsEntry 15 }
|
|
|
|
fcmPortDelimiterErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of invalid frame delimiters received at this
|
|
port. An example is a frame with a class 2 start and a
|
|
class 3 at the end."
|
|
::= { fcmPortErrorsEntry 16 }
|
|
|
|
fcmPortEncodingDisparityErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of encoding disparity errors received at this
|
|
port."
|
|
::= { fcmPortErrorsEntry 17 }
|
|
|
|
fcmPortOtherErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of errors that were detected on this port but
|
|
not counted by any other error counter in this row."
|
|
::= { fcmPortErrorsEntry 18 }
|
|
|
|
--********************************
|
|
-- The Fibre Channel Fx_Port Table
|
|
--
|
|
|
|
fcmFxPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmFxPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about Fibre Channel ports that is
|
|
specific to Fx_Ports. This table will contain one entry for
|
|
each fcmPortTable entry that represents an Fx_Port."
|
|
::= { fcmgmtObjects 7 }
|
|
|
|
fcmFxPortEntry OBJECT-TYPE
|
|
SYNTAX FcmFxPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry contains information about a specific Fx_Port."
|
|
INDEX { ifIndex }
|
|
::= { fcmFxPortTable 1 }
|
|
|
|
FcmFxPortEntry ::=
|
|
SEQUENCE {
|
|
fcmFxPortRatov Unsigned32,
|
|
fcmFxPortEdtov Unsigned32,
|
|
fcmFxPortRttov Unsigned32,
|
|
fcmFxPortHoldTime Unsigned32,
|
|
fcmFxPortCapBbCreditMax FcBbCredit,
|
|
fcmFxPortCapBbCreditMin FcBbCredit,
|
|
fcmFxPortCapDataFieldSizeMax FcDataFieldSize,
|
|
fcmFxPortCapDataFieldSizeMin FcDataFieldSize,
|
|
fcmFxPortCapClass2SeqDeliv TruthValue,
|
|
fcmFxPortCapClass3SeqDeliv TruthValue,
|
|
fcmFxPortCapHoldTimeMax Unsigned32,
|
|
fcmFxPortCapHoldTimeMin Unsigned32
|
|
}
|
|
|
|
fcmFxPortRatov OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Resource_Allocation_Timeout Value configured for this
|
|
Fx_Port. This is used as the timeout value for determining
|
|
when to reuse an Nx_Port resource such as a
|
|
|
|
Recovery_Qualifier. It represents the Error_Detect_Timeout
|
|
value (see fcmFxPortEdtov) plus twice the maximum time that
|
|
a frame may be delayed within the Fabric and still be
|
|
delivered."
|
|
::= { fcmFxPortEntry 1 }
|
|
|
|
fcmFxPortEdtov OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Error_Detect_Timeout value configured for this Fx_Port.
|
|
This is used as the timeout value for detecting an error
|
|
condition."
|
|
::= { fcmFxPortEntry 2 }
|
|
|
|
fcmFxPortRttov OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Receiver_Transmitter_Timeout value of this Fx_Port.
|
|
This is used by the receiver logic to detect a Loss of
|
|
Synchronization."
|
|
::= { fcmFxPortEntry 3 }
|
|
|
|
fcmFxPortHoldTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum time that this Fx_Port shall hold a frame
|
|
before discarding the frame if it is unable to deliver the
|
|
frame. The value 0 means that this Fx_Port does not support
|
|
this parameter."
|
|
::= { fcmFxPortEntry 4 }
|
|
|
|
fcmFxPortCapBbCreditMax OBJECT-TYPE
|
|
SYNTAX FcBbCredit
|
|
UNITS "buffers"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of receive buffers that this port is
|
|
capable of making available for holding frames from attached
|
|
|
|
Nx_Port(s)."
|
|
::= { fcmFxPortEntry 5 }
|
|
|
|
fcmFxPortCapBbCreditMin OBJECT-TYPE
|
|
SYNTAX FcBbCredit
|
|
UNITS "buffers"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum number of receive buffers that this port is
|
|
capable of making available for holding frames from attached
|
|
Nx_Port(s)."
|
|
::= { fcmFxPortEntry 6 }
|
|
|
|
fcmFxPortCapDataFieldSizeMax OBJECT-TYPE
|
|
SYNTAX FcDataFieldSize
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum size in bytes of the Data Field in a frame that
|
|
this Fx_Port is capable of receiving from an attached
|
|
Nx_Port."
|
|
::= { fcmFxPortEntry 7 }
|
|
|
|
fcmFxPortCapDataFieldSizeMin OBJECT-TYPE
|
|
SYNTAX FcDataFieldSize
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum size in bytes of the Data Field in a frame that
|
|
this Fx_Port is capable of receiving from an attached
|
|
Nx_Port."
|
|
::= { fcmFxPortEntry 8 }
|
|
|
|
fcmFxPortCapClass2SeqDeliv OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of whether this Fx_Port is capable of
|
|
supporting Class 2 Sequential Delivery."
|
|
::= { fcmFxPortEntry 9 }
|
|
|
|
fcmFxPortCapClass3SeqDeliv OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of whether this Fx_Port is capable of
|
|
supporting Class 3 Sequential Delivery."
|
|
::= { fcmFxPortEntry 10 }
|
|
|
|
fcmFxPortCapHoldTimeMax OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum holding time that this Fx_Port is capable of
|
|
supporting."
|
|
::= { fcmFxPortEntry 11 }
|
|
|
|
fcmFxPortCapHoldTimeMin OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum holding time that this Fx_Port is capable of
|
|
supporting."
|
|
::= { fcmFxPortEntry 12 }
|
|
|
|
--********************************
|
|
-- The Fibre Channel Inter-Switch Port Table
|
|
--
|
|
|
|
fcmISPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmISPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about E_Ports, B_Ports, and any
|
|
other type of Fibre Channel port to which inter-switch links
|
|
can be connected. This table will contain one entry for
|
|
each fcmPortTable entry that represents such a port."
|
|
::= { fcmgmtObjects 8 }
|
|
|
|
fcmISPortEntry OBJECT-TYPE
|
|
SYNTAX FcmISPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry contains information about a specific port
|
|
connected to an inter-switch link."
|
|
INDEX { ifIndex }
|
|
::= { fcmISPortTable 1 }
|
|
|
|
FcmISPortEntry ::=
|
|
SEQUENCE {
|
|
fcmISPortClassFCredit FcBbCredit,
|
|
fcmISPortClassFDataFieldSize FcDataFieldSize
|
|
}
|
|
|
|
fcmISPortClassFCredit OBJECT-TYPE
|
|
SYNTAX FcBbCredit
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of Class F data frames that can be
|
|
transmitted by the inter-switch port without receipt of ACK
|
|
or Link_Response frames."
|
|
::= { fcmISPortEntry 1 }
|
|
|
|
fcmISPortClassFDataFieldSize OBJECT-TYPE
|
|
SYNTAX FcDataFieldSize
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Receive Data Field Size that the inter-switch port has
|
|
agreed to support for Class F frames to/from this port. The
|
|
size specifies the largest Data Field Size for an FT_1
|
|
frame."
|
|
::= { fcmISPortEntry 2 }
|
|
|
|
--********************************
|
|
-- The Fabric Login table
|
|
--
|
|
-- This table contains the information held by FC switches
|
|
-- about the Nx_Ports that are logged-in/attached to their
|
|
-- Fx_Ports
|
|
|
|
fcmFLoginTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmFLoginEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains one entry for each Nx_Port logged-
|
|
in/attached to a particular Fx_Port in the switch. Each
|
|
entry contains the services parameters established during
|
|
the most recent Fabric Login, explicit or implicit. Note
|
|
that an Fx_Port may have one or more Nx_Ports attached to
|
|
it."
|
|
::= { fcmgmtObjects 9 }
|
|
|
|
fcmFLoginEntry OBJECT-TYPE
|
|
SYNTAX FcmFLoginEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing service parameters established from a
|
|
successful Fabric Login."
|
|
INDEX { ifIndex, fcmFLoginNxPortIndex }
|
|
::= { fcmFLoginTable 1 }
|
|
|
|
FcmFLoginEntry ::=
|
|
SEQUENCE {
|
|
fcmFLoginNxPortIndex Unsigned32,
|
|
fcmFLoginPortWwn FcNameIdOrZero,
|
|
fcmFLoginNodeWwn FcNameIdOrZero,
|
|
fcmFLoginBbCreditModel FcBbCreditModel,
|
|
fcmFLoginBbCredit FcBbCredit,
|
|
fcmFLoginClassesAgreed FcClasses,
|
|
fcmFLoginClass2SeqDelivAgreed TruthValue,
|
|
fcmFLoginClass2DataFieldSize FcDataFieldSize,
|
|
fcmFLoginClass3SeqDelivAgreed TruthValue,
|
|
fcmFLoginClass3DataFieldSize FcDataFieldSize
|
|
}
|
|
|
|
fcmFLoginNxPortIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary integer that uniquely identifies an Nx_Port
|
|
amongst all those attached to the Fx_Port indicated by
|
|
ifIndex.
|
|
|
|
After a value of this object is assigned to a particular
|
|
Nx_Port, that value can be re-used when and only when it is
|
|
assigned to the same Nx_Port, or, after a reset of the value
|
|
of the relevant instance of ifCounterDiscontinuityTime."
|
|
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
|
|
::= { fcmFLoginEntry 1 }
|
|
|
|
fcmFLoginPortWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port name of the attached Nx_Port, or the zero-length
|
|
string if unknown."
|
|
::= { fcmFLoginEntry 2 }
|
|
|
|
fcmFLoginNodeWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node name of the attached Nx_Port, or the zero-length
|
|
string if unknown."
|
|
::= { fcmFLoginEntry 3 }
|
|
|
|
fcmFLoginBbCreditModel OBJECT-TYPE
|
|
SYNTAX FcBbCreditModel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The buffer-to-buffer credit model in use by the Fx_Port."
|
|
::= { fcmFLoginEntry 4 }
|
|
|
|
fcmFLoginBbCredit OBJECT-TYPE
|
|
SYNTAX FcBbCredit
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of buffers available for holding frames to be
|
|
|
|
transmitted to the attached Nx_Port. These buffers are for
|
|
buffer-to-buffer flow control in the direction from Fx_Port
|
|
to Nx_Port."
|
|
::= { fcmFLoginEntry 5 }
|
|
|
|
fcmFLoginClassesAgreed OBJECT-TYPE
|
|
SYNTAX FcClasses
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Classes of Service that the Fx_Port has agreed to
|
|
support for this Nx_Port."
|
|
::= { fcmFLoginEntry 6 }
|
|
|
|
fcmFLoginClass2SeqDelivAgreed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of whether the Fx_Port has agreed to support
|
|
Class 2 sequential delivery for this Nx_Port. This is only
|
|
meaningful if Class 2 service has been agreed upon."
|
|
::= { fcmFLoginEntry 7 }
|
|
|
|
fcmFLoginClass2DataFieldSize OBJECT-TYPE
|
|
SYNTAX FcDataFieldSize
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Receive Data Field Size that the Fx_Port has agreed to
|
|
support for Class 2 frames to/from this Nx_Port. The size
|
|
specifies the largest Data Field Size for an FT_1 frame.
|
|
This is only meaningful if Class 2 service has been agreed
|
|
upon."
|
|
::= { fcmFLoginEntry 8 }
|
|
|
|
fcmFLoginClass3SeqDelivAgreed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of whether the Fx_Port has agreed to support
|
|
Class 3 sequential delivery for this Nx_Port. This is only
|
|
meaningful if Class 3 service has been agreed upon."
|
|
::= { fcmFLoginEntry 9 }
|
|
|
|
fcmFLoginClass3DataFieldSize OBJECT-TYPE
|
|
SYNTAX FcDataFieldSize
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Receive Data Field Size that the Fx_Port has agreed to
|
|
support for Class 3 frames to/from this Nx_Port. The size
|
|
specifies the largest Data Field Size for an FT_1 frame.
|
|
This is only meaningful if Class 3 service has been agreed
|
|
upon."
|
|
::= { fcmFLoginEntry 10 }
|
|
|
|
--********************************
|
|
-- The Link table
|
|
--
|
|
-- This table is intended to assist management applications
|
|
-- in determining the topology of the network. The table
|
|
-- contains any recent information the known to the agent
|
|
-- about Fibre Channel links, not only those that terminate at
|
|
-- a local port but also any others for which information
|
|
-- is known.
|
|
|
|
fcmLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FcmLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing any Fibre Channel link information that
|
|
is known to local Fibre Channel managed instances. One end
|
|
of such a link is typically at a local port, but the table
|
|
can also contain information on links for which neither end
|
|
is a local port.
|
|
|
|
If one end of a link terminates locally, then that end is
|
|
termed 'end1'; the other end is termed 'end2'."
|
|
::= { fcmgmtObjects 10 }
|
|
|
|
fcmLinkEntry OBJECT-TYPE
|
|
SYNTAX FcmLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information that a particular Fibre
|
|
Channel managed instance has about a Fibre Channel link.
|
|
|
|
The two ends of the link are called 'end1' and 'end2'."
|
|
INDEX { fcmInstanceIndex, fcmLinkIndex }
|
|
::= { fcmLinkTable 1 }
|
|
|
|
FcmLinkEntry ::=
|
|
SEQUENCE {
|
|
fcmLinkIndex Unsigned32,
|
|
fcmLinkEnd1NodeWwn FcNameIdOrZero,
|
|
fcmLinkEnd1PhysPortNumber Unsigned32,
|
|
fcmLinkEnd1PortWwn FcNameIdOrZero,
|
|
fcmLinkEnd2NodeWwn FcNameIdOrZero,
|
|
fcmLinkEnd2PhysPortNumber Unsigned32,
|
|
fcmLinkEnd2PortWwn FcNameIdOrZero,
|
|
fcmLinkEnd2AgentAddress SnmpAdminString,
|
|
fcmLinkEnd2PortType FcPortType,
|
|
fcmLinkEnd2UnitType FcUnitFunctions,
|
|
fcmLinkEnd2FcAddressId FcAddressIdOrZero
|
|
}
|
|
|
|
fcmLinkIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary integer that uniquely identifies one link
|
|
within the set of links about which a particular managed
|
|
instance has information."
|
|
::= { fcmLinkEntry 1 }
|
|
|
|
fcmLinkEnd1NodeWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node name of end1, or the zero-length string if
|
|
unknown."
|
|
::= { fcmLinkEntry 2 }
|
|
|
|
fcmLinkEnd1PhysPortNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical port number of end1, or zero if unknown."
|
|
REFERENCE
|
|
"FC-GS-3, section 6.1.2.2.5"
|
|
::= { fcmLinkEntry 3 }
|
|
|
|
fcmLinkEnd1PortWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port WWN of end1, or the zero-length string if unknown.
|
|
('end1' is local if this value is equal to the value of
|
|
fcmPortWwn in one of the rows of the fcmPortTable.)"
|
|
::= { fcmLinkEntry 4 }
|
|
|
|
fcmLinkEnd2NodeWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node name of end2, or the zero-length string if
|
|
unknown."
|
|
::= { fcmLinkEntry 5 }
|
|
|
|
fcmLinkEnd2PhysPortNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical port number of end2, or zero if unknown."
|
|
REFERENCE
|
|
"FC-GS-3, section 6.1.2.2.5"
|
|
::= { fcmLinkEntry 6 }
|
|
|
|
fcmLinkEnd2PortWwn OBJECT-TYPE
|
|
SYNTAX FcNameIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port WWN of end2, or the zero-length string if
|
|
unknown."
|
|
::= { fcmLinkEntry 7 }
|
|
|
|
fcmLinkEnd2AgentAddress OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address of the management agent for the Fibre Channel
|
|
Interconnect Element or Platform of which end2 is a part.
|
|
The GS-4 specification provides some information about
|
|
management agents. If the address is unknown, the value of
|
|
this object is the zero-length string."
|
|
|
|
REFERENCE
|
|
"FC-GS-3, section 6.1.2.1.7"
|
|
::= { fcmLinkEntry 8 }
|
|
|
|
fcmLinkEnd2PortType OBJECT-TYPE
|
|
SYNTAX FcPortType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port type of end2."
|
|
REFERENCE
|
|
"FC-GS-3, section 6.1.2.2.2"
|
|
::= { fcmLinkEntry 9 }
|
|
|
|
fcmLinkEnd2UnitType OBJECT-TYPE
|
|
SYNTAX FcUnitFunctions
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of/function(s) performed by the Fibre Channel
|
|
Interconnect Element or Platform of which end2 is a part."
|
|
REFERENCE
|
|
"FC-GS-3, sections 6.1.2.1.2 and 6.1.2.3.2"
|
|
::= { fcmLinkEntry 10 }
|
|
|
|
fcmLinkEnd2FcAddressId OBJECT-TYPE
|
|
SYNTAX FcAddressIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Fibre Channel Address ID of end2, or the zero-length
|
|
string if unknown."
|
|
::= { fcmLinkEntry 11 }
|
|
|
|
--********************************
|
|
-- Conformance Section
|
|
--
|
|
|
|
fcmgmtCompliances OBJECT IDENTIFIER ::= { fcmgmtConformance 1 }
|
|
fcmgmtGroups OBJECT IDENTIFIER ::= { fcmgmtConformance 2 }
|
|
|
|
fcmgmtCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the requirements for compliance to this Fibre
|
|
Channel Management MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { fcmInstanceBasicGroup,
|
|
fcmPortBasicGroup,
|
|
fcmPortErrorsGroup }
|
|
|
|
GROUP fcmPortStatsGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for all systems that
|
|
are able to support the Counter64 date type."
|
|
|
|
GROUP fcmPortClass23StatsGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for systems that
|
|
keep class-specific traffic statistics on Class 2
|
|
and Class 3 traffic and are able to support the
|
|
Counter64 date type."
|
|
|
|
GROUP fcmPortClassFStatsGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for FC switches that
|
|
keep statistics on Class F traffic."
|
|
|
|
GROUP fcmPortLcStatsGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for agents that can not
|
|
support the Counter64 data type and/or need to provide
|
|
information accessible by SNMPv1 applications."
|
|
|
|
GROUP fcmSwitchBasicGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for Fibre Channel
|
|
managed instances that manage Fibre Channel
|
|
switches."
|
|
|
|
GROUP fcmSwitchPortGroup
|
|
DESCRIPTION
|
|
|
|
"This group is mandatory only for Fibre Channel
|
|
managed instances that manage Fibre Channel
|
|
switches."
|
|
|
|
GROUP fcmSwitchLoginGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for Fibre Channel
|
|
managed instances that manage Fibre Channel
|
|
switches."
|
|
|
|
GROUP fcmLinkBasicGroup
|
|
DESCRIPTION
|
|
"This group is optional."
|
|
|
|
OBJECT fcmInstancePhysicalIndex
|
|
SYNTAX Integer32 (0)
|
|
DESCRIPTION
|
|
"Implementation of a non-zero value is not required."
|
|
|
|
OBJECT fcmInstanceSoftwareIndex
|
|
SYNTAX Integer32 (0)
|
|
DESCRIPTION
|
|
"Implementation of a non-zero value is not required."
|
|
|
|
OBJECT fcmInstanceTextName
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT fcmInstanceDescr
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT fcmPortAdminType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT fcmPortAdminSpeed
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT fcmSwitchDomainId
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT fcmISPortClassFCredit
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { fcmgmtCompliances 1 }
|
|
|
|
--********************************
|
|
-- Object Groups
|
|
--
|
|
|
|
fcmInstanceBasicGroup OBJECT-GROUP
|
|
OBJECTS { fcmInstanceWwn, fcmInstanceFunctions,
|
|
fcmInstancePhysicalIndex, fcmInstanceSoftwareIndex,
|
|
fcmInstanceStatus, fcmInstanceTextName,
|
|
fcmInstanceDescr, fcmInstanceFabricId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic information about Fibre Channel managed instances."
|
|
::= { fcmgmtGroups 1 }
|
|
|
|
fcmSwitchBasicGroup OBJECT-GROUP
|
|
OBJECTS { fcmSwitchDomainId, fcmSwitchPrincipal, fcmSwitchWWN }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic information about Fibre Channel switches."
|
|
::= { fcmgmtGroups 2 }
|
|
|
|
fcmPortBasicGroup OBJECT-GROUP
|
|
OBJECTS { fcmPortInstanceIndex, fcmPortWwn, fcmPortNodeWwn,
|
|
fcmPortAdminType, fcmPortOperType, fcmPortFcCapClass,
|
|
fcmPortFcOperClass, fcmPortTransmitterType,
|
|
fcmPortConnectorType, fcmPortSerialNumber,
|
|
fcmPortPhysicalNumber, fcmPortAdminSpeed,
|
|
fcmPortCapProtocols, fcmPortOperProtocols }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic information about Fibre Channel ports."
|
|
::= { fcmgmtGroups 3 }
|
|
|
|
fcmPortStatsGroup OBJECT-GROUP
|
|
OBJECTS { fcmPortBBCreditZeros, fcmPortFullInputBuffers }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Traffic statistics, which are not specific to any one class
|
|
of service, for Fibre Channel ports."
|
|
::= { fcmgmtGroups 4 }
|
|
|
|
fcmPortClass23StatsGroup OBJECT-GROUP
|
|
OBJECTS { fcmPortClass2RxFrames, fcmPortClass2RxOctets,
|
|
fcmPortClass2TxFrames, fcmPortClass2TxOctets,
|
|
fcmPortClass2Discards, fcmPortClass2RxFbsyFrames,
|
|
fcmPortClass2RxPbsyFrames,
|
|
fcmPortClass2RxFrjtFrames,
|
|
fcmPortClass2RxPrjtFrames,
|
|
fcmPortClass2TxFbsyFrames,
|
|
fcmPortClass2TxPbsyFrames,
|
|
fcmPortClass2TxFrjtFrames,
|
|
fcmPortClass2TxPrjtFrames, fcmPortClass3RxFrames,
|
|
fcmPortClass3RxOctets, fcmPortClass3TxFrames,
|
|
fcmPortClass3TxOctets, fcmPortClass3Discards }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Traffic statistics for Class 2 and Class 3 traffic on Fibre
|
|
Channel ports."
|
|
::= { fcmgmtGroups 5 }
|
|
|
|
fcmPortClassFStatsGroup OBJECT-GROUP
|
|
OBJECTS { fcmPortClassFRxFrames,
|
|
fcmPortClassFRxOctets,
|
|
fcmPortClassFTxFrames,
|
|
fcmPortClassFTxOctets,
|
|
fcmPortClassFDiscards }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Traffic statistics for Class F traffic on Fibre Channel
|
|
ports."
|
|
::= { fcmgmtGroups 6 }
|
|
|
|
fcmPortLcStatsGroup OBJECT-GROUP
|
|
OBJECTS { fcmPortLcBBCreditZeros, fcmPortLcFullInputBuffers,
|
|
fcmPortLcClass2RxFrames, fcmPortLcClass2RxOctets,
|
|
fcmPortLcClass2TxFrames, fcmPortLcClass2TxOctets,
|
|
fcmPortLcClass2Discards, fcmPortLcClass3Discards,
|
|
fcmPortLcClass3RxFrames, fcmPortLcClass3RxOctets,
|
|
fcmPortLcClass3TxFrames, fcmPortLcClass3TxOctets,
|
|
fcmPortLcClass2RxFbsyFrames,
|
|
fcmPortLcClass2RxPbsyFrames,
|
|
fcmPortLcClass2RxFrjtFrames,
|
|
fcmPortLcClass2RxPrjtFrames,
|
|
fcmPortLcClass2TxFbsyFrames,
|
|
fcmPortLcClass2TxPbsyFrames,
|
|
fcmPortLcClass2TxFrjtFrames,
|
|
fcmPortLcClass2TxPrjtFrames }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"Low-capacity (32-bit) statistics for Fibre Channel ports."
|
|
::= { fcmgmtGroups 7 }
|
|
|
|
fcmPortErrorsGroup OBJECT-GROUP
|
|
OBJECTS { fcmPortRxLinkResets, fcmPortTxLinkResets,
|
|
fcmPortLinkResets, fcmPortRxOfflineSequences,
|
|
fcmPortTxOfflineSequences, fcmPortLinkFailures,
|
|
fcmPortLossofSynchs, fcmPortLossofSignals,
|
|
fcmPortPrimSeqProtocolErrors, fcmPortInvalidTxWords,
|
|
fcmPortInvalidCRCs, fcmPortInvalidOrderedSets,
|
|
fcmPortFrameTooLongs, fcmPortTruncatedFrames,
|
|
fcmPortAddressErrors, fcmPortDelimiterErrors,
|
|
fcmPortEncodingDisparityErrors,
|
|
fcmPortOtherErrors }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error statistics for Fibre Channel ports."
|
|
::= { fcmgmtGroups 8 }
|
|
|
|
fcmSwitchPortGroup OBJECT-GROUP
|
|
OBJECTS { fcmFxPortRatov, fcmFxPortEdtov, fcmFxPortRttov,
|
|
fcmFxPortHoldTime, fcmFxPortCapBbCreditMax,
|
|
fcmFxPortCapBbCreditMin,
|
|
fcmFxPortCapDataFieldSizeMax,
|
|
fcmFxPortCapDataFieldSizeMin,
|
|
fcmFxPortCapClass2SeqDeliv,
|
|
fcmFxPortCapClass3SeqDeliv,
|
|
fcmFxPortCapHoldTimeMax,
|
|
fcmFxPortCapHoldTimeMin,
|
|
fcmISPortClassFCredit,
|
|
fcmISPortClassFDataFieldSize }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about ports on a Fibre Channel switch."
|
|
::= { fcmgmtGroups 9 }
|
|
|
|
fcmSwitchLoginGroup OBJECT-GROUP
|
|
OBJECTS { fcmFLoginPortWwn, fcmFLoginNodeWwn,
|
|
fcmFLoginBbCreditModel, fcmFLoginBbCredit,
|
|
fcmFLoginClassesAgreed,
|
|
fcmFLoginClass2SeqDelivAgreed,
|
|
fcmFLoginClass2DataFieldSize,
|
|
fcmFLoginClass3SeqDelivAgreed,
|
|
fcmFLoginClass3DataFieldSize }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information known to a Fibre Channel switch about
|
|
attached/logged-in Nx_Ports."
|
|
|
|
::= { fcmgmtGroups 10 }
|
|
|
|
fcmLinkBasicGroup OBJECT-GROUP
|
|
OBJECTS { fcmLinkEnd1NodeWwn , fcmLinkEnd1PhysPortNumber,
|
|
fcmLinkEnd1PortWwn, fcmLinkEnd2NodeWwn ,
|
|
fcmLinkEnd2PhysPortNumber, fcmLinkEnd2PortWwn,
|
|
fcmLinkEnd2AgentAddress, fcmLinkEnd2PortType,
|
|
fcmLinkEnd2UnitType, fcmLinkEnd2FcAddressId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about Fibre Channel links."
|
|
::= { fcmgmtGroups 11 }
|
|
|
|
END
|
|
|
|
|
|
|