EXTREME-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
TEXTUAL-CONVENTION FROM SNMPv2-TC
NOTIFICATION-TYPE FROM SNMPv2-SMI
MODULE-IDENTITY FROM SNMPv2-SMI
OBJECT-TYPE FROM SNMPv2-SMI
Integer32, Unsigned32 FROM SNMPv2-SMI
TruthValue FROM SNMPv2-TC
DisplayString FROM RFC1213-MIB
extremeAgent FROM EXTREME-BASE-MIB
PortList FROM EXTREME-BASE-MIB
sysDescr,sysUpTime, ifDescr FROM RFC1213-MIB
IpAddress FROM SNMPv2-SMI;
extremeSystem MODULE-IDENTITY
LAST-UPDATED "200503220000Z"
ORGANIZATION "Extreme Networks, Inc."
CONTACT-INFO "www.extremenetworks.com"
DESCRIPTION "Extreme System objects: objects common to all platforms"
::= { extremeAgent 1 }
SlotType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The type of the slot. It is used both for the configured
as well as the inserted slot types."
SYNTAX INTEGER {
none(1),
fe32(2),
g4x(3),
g6x(4),
fe32fx(5),
msm(6),
f48ti(7),
g8xi(8),
g8ti(9),
g12sxi(10),
g12ti(11),
msm64i(18),
alpine3808(19),
alpine3804(20),
fm32t(21),
gm4x(22),
gm4sx(23),
gm4t(24),
wdm8(25),
fm24f(26),
fm24sf(27),
fm24te(28),
f96ti(29),
wdm4(30),
f32fi(31),
tenGx3(32),
tenGigLR(33),
g16x3(34),
g24t3(35),
gm16x3(36),
gm16t3(37),
fm16t3(38),
fm32p(39),
fm8v(50), -- vdsl blade
wm4t1(51), -- 4port t1
wm4t3(52), -- 4port t3
wm1t3(53), -- 1port t3
wm4e1(54), -- 4port e1
alpine3802(55),
p3c(101),
p12c(102),
arm(103),
mpls(104),
sma(105),
p48c(106),
a3c(107),
a12c(108),
pxm(200),
s300fixed(201),
msm3(202),
msm1(203),
msm1xl(204),
s300expansion(301),
g60t(400),
g60x(401),
teng6x(402),
msmG8x(414),
g48T(416),
g48P(417),
tenG4X(419),
tenG2X(420),
g20X(421),
tenG2XH(422),
g48te(433),
g48ta(434),
g48pe(435),
g48x(437)
}
PowerValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The input power value of the switch."
SYNTAX INTEGER {
v110 (1),
v220 (2),
v48DC (3),
unknown(4)
}
extremeSystemCommon OBJECT IDENTIFIER
::= { extremeSystem 1 }
--
-- System group
--
-- Objects common to all platforms
--
-- Configuration save objects. These objects are used by the network
-- management application to save configuration changes into the
-- persistant store. There are 2 stores on the device; a primary and
-- a secondary.
extremeSaveConfiguration OBJECT-TYPE
SYNTAX INTEGER {
saveToPrimary(1),
saveToSecondary(2),
saveToCurrent(3),
factoryDefault(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set, the device will copy the contents
of the configuration database to a buffer and save it to the
persistant store specified by the value of the object. The
save is performed asynchronously, and the snmp agent will
continue to respond to both gets and sets while the save is
taking place. A network management application may use the
extremeSaveStatus object to determine when the asynchronous
save operation has completed."
::= { extremeSystemCommon 3 }
extremeSaveStatus OBJECT-TYPE
SYNTAX INTEGER { saveInProgress(1), saveNotInProgress(2), saveNotReady(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object will return the status of a save operation invoked
by setting the extremeSaveConfiguration object. A network
management application can read this object to determine that a
save operation has completed."
::= { extremeSystemCommon 4 }
extremeCurrentConfigInUse OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2),
other(3),
factoryDefault(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows which NVRAM configuration store was used at last boot"
::= { extremeSystemCommon 5 }
extremeConfigToUseOnReboot OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2),
other(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which NVRAM configuration store will be used
on next reboot."
::= { extremeSystemCommon 6 }
extremeOverTemperatureAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm status of overtemperature sensor in device
enclosure."
::= { extremeSystemCommon 7 }
extremeCurrentTemperature OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current temperature in degrees celcius measured inside
device enclosure."
::= { extremeSystemCommon 8 }
--
-- Table of operational status of all internal Fans
--
extremeFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of operational status of all internal cooling fans."
::= { extremeSystemCommon 9 }
extremeFanStatusEntry OBJECT-TYPE
SYNTAX ExtremeFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in table of all internal cooling fans."
INDEX { extremeFanNumber }
::= { extremeFanStatusTable 1 }
ExtremeFanStatusEntry ::=
SEQUENCE {
extremeFanNumber Integer32,
extremeFanOperational TruthValue,
extremeFanEntPhysicalIndex Integer32
}
extremeFanNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifier of cooling fan, numbered from the front and/or
left side of device."
::= { extremeFanStatusEntry 1 }
extremeFanOperational OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of a cooling fan."
::= { extremeFanStatusEntry 2 }
extremeFanEntPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entity index for this fan entity in the entityPhysicalTable table of the
entity MIB."
::= { extremeFanStatusEntry 3 }
extremePrimaryPowerOperational OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of internal power supply of a device."
::= { extremeSystemCommon 10 }
extremeRedundantPowerStatus OBJECT-TYPE
SYNTAX INTEGER { notPresent(1), presentOK(2), presentNotOK(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of an external redundant power supply to a device."
::= { extremeSystemCommon 11 }
extremeRedundantPowerAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state of an external redundant power supply to a device.
Alarm state indicates either fan failure or overtemperature
condition."
::= { extremeSystemCommon 12 }
extremePrimarySoftwareRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software revision of the primary image stored in
this device. This string will have a zero length if
the revision is unknown, invalid or not present. This
will also be reported in RMON2 probeSoftwareRev if this
is the software image currently running in the device."
::= { extremeSystemCommon 13 }
extremeSecondarySoftwareRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software revision of the secondary image stored in
this device. This string will have a zero length if
the revision is unknown, invalid or not present. This
will also be reported in RMON2 probeSoftwareRev if this
is the software image currently running in the device."
::= { extremeSystemCommon 14 }
extremeImageToUseOnReboot OBJECT-TYPE
SYNTAX INTEGER { primary(1), secondary(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which image will be used
on next reboot."
::= { extremeSystemCommon 15 }
extremeSystemID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the System ID of the Summit Switch."
::= { extremeSystemCommon 16 }
extremeSystemBoardID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the Board ID of the Summit Switch."
::= { extremeSystemCommon 17 }
extremeSystemLeftBoardID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the Left Board ID of the Summit Switch."
::= { extremeSystemCommon 18 }
extremeSystemRightBoardID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the Right Board ID of the Summit Switch."
::= { extremeSystemCommon 19 }
-- Add variables to report power supply data
extremeInputPowerVoltage OBJECT-TYPE
SYNTAX PowerValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input power voltage at which the system is currently operating."
::= { extremeSystemCommon 20 }
extremePowerStatus OBJECT-TYPE
SYNTAX INTEGER { notPresent(1), presentOK(2), presentNotOK(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of the power supply to a device."
::= { extremeSystemCommon 21 }
extremePowerAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state of the power supply to a device.
Alarm state indicates either fan failure or overtemperature
condition."
::= { extremeSystemCommon 22 }
extremeRmonEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this to true will cause the agent to
start collecting RMON statistics."
::= { extremeSystemCommon 23 }
-- OID extremeSystemCommon.24 has been deprecated and extremeCpuTasktable
-- has been moved to extremeSystemCommon.29 with new name extremeCpuTask2table
extremeBootROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software revision of the bootrom on the device.
This string will have a zero length if the revision is
unknown or invalid."
::= { extremeSystemCommon 25 }
extremeDot1dTpFdbTableEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this to true will cause GetNext operations on the dot1dTpFdbTable to be allowed. Note that Get operations are always allowed."
::= { extremeSystemCommon 26 }
extremePowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremePowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of status of all power supplies in the system."
::= { extremeSystemCommon 27 }
extremePowerSupplyEntry OBJECT-TYPE
SYNTAX ExtremePowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry indicating the status of a specific power supply."
INDEX { extremePowerSupplyNumber }
::= { extremePowerSupplyTable 1 }
ExtremePowerSupplyEntry ::=
SEQUENCE {
extremePowerSupplyNumber
Integer32,
extremePowerSupplyStatus
INTEGER,
extremePowerSupplyInputVoltage
PowerValue,
extremePowerSupplySerialNumber
DisplayString,
extremePowerSupplyEntPhysicalIndex
Integer32
}
extremePowerSupplyNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Power supply number."
::= { extremePowerSupplyEntry 1 }
extremePowerSupplyStatus OBJECT-TYPE
SYNTAX INTEGER { notPresent(1), presentOK(2), presentNotOK(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the power supply."
::= { extremePowerSupplyEntry 2 }
extremeCpuAggregateUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The aggregate CPU utilization since
the time the start started executing."
::= { extremeSystemCommon 28 }
extremePowerSupplyInputVoltage OBJECT-TYPE
SYNTAX PowerValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input voltage of the power supply"
::= { extremePowerSupplyEntry 3 }
extremePowerSupplySerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The serial number of the power supply unit."
::= { extremePowerSupplyEntry 4 }
extremePowerSupplyEntPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The entity index for this psu entity in the entityPhysicalTable
of the entity MIB."
::= { extremePowerSupplyEntry 5 }
--
-- The CPU Task table lists all executing tasks
--
extremeCpuTask2Table OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeCpuTask2Entry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of CPU tasks that are active."
::= { extremeSystemCommon 29 }
extremeCpuTask2Entry OBJECT-TYPE
SYNTAX ExtremeCpuTask2Entry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in table of describes a single task."
INDEX { extremeCpuTask2CpuId, extremeCpuTask2Name }
::= { extremeCpuTask2Table 1 }
ExtremeCpuTask2Entry ::=
SEQUENCE {
extremeCpuTask2CpuId
Unsigned32,
extremeCpuTask2Name
DisplayString,
extremeCpuTask2Id
Unsigned32,
extremeCpuTask2Pc
Unsigned32,
extremeCpuTask2Status
DisplayString,
extremeCpuTask2Utilization
Unsigned32,
extremeCpuTask2MaxUtilization
Unsigned32
}
extremeCpuTask2CpuId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"CPU on which this task last executed or is executing.
The primary CPU has a value of 1."
::= { extremeCpuTask2Entry 1 }
extremeCpuTask2Name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Name associated with the reported task id."
::= { extremeCpuTask2Entry 2 }
extremeCpuTask2Id OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Task identifier assigned by the operating system when
this task is spawned."
::= { extremeCpuTask2Entry 3 }
extremeCpuTask2Pc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The value of the program counter for this task.
It indicates the address of the next instruction
that would be executed once the operating system
resumes this task."
::= { extremeCpuTask2Entry 4 }
extremeCpuTask2Status OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The current status of the task as reported by the
operating system."
::= { extremeCpuTask2Entry 5 }
extremeCpuTask2Utilization OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The current CPU utilization by this task. This
is the utilization when the task last executed."
::= { extremeCpuTask2Entry 6 }
extremeCpuTask2MaxUtilization OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The maximum CPU utilization by this task since
the time the start started executing. This value
may be cleared."
::= { extremeCpuTask2Entry 7 }
extremeAuthFailSrcAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The IP address of the originator of the bad SNMP
request that caused the generation of an authentication
failure trap."
::= { extremeSystemCommon 30 }
extremeCpuTransmitPriority OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
high(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The CPU transmit priority."
::= { extremeSystemCommon 31 }
extremeImageBooted OBJECT-TYPE
SYNTAX INTEGER { primary(1), secondary(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The image with which the switch was last booted, using which it is currently running."
::= { extremeSystemCommon 32 }
extremeMsmFailoverCause OBJECT-TYPE
SYNTAX INTEGER { never(1),
admin(2),
exception(3),
removal(4),
hwFailure(5),
watchdog(6),
keepalive(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cause of the last MSM failover. never(1) means an
MSM Failover has not occurred since the last reboot.
admin(2) means the failover was initiated by the user.
exception(3) means the former master MSM encountered a
software exception condition. removal(4) means the master
MSM was physically removed from the chassis. hwFailure(5)
means a diagnostic failure was detected in the master MSM.
watchdog(6) means that the master MSM hardware watchdog
timer expired. keepalive(7) means the master MSM failed to
respond to slave keepalive requests. The MSM failover will
have been hitless only in the admin(2) and exception(3)
cases "
::= { extremeSystemCommon 33 }
extremeImageTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeImageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each software image."
::= { extremeSystemCommon 34 }
extremeImageEntry OBJECT-TYPE
SYNTAX ExtremeImageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing information about each software image."
INDEX { extremeImageNumber }
::= { extremeImageTable 1 }
ExtremeImageEntry ::= SEQUENCE {
extremeImageNumber INTEGER,
extremeMajorVersion Integer32,
extremeSubMajorVersion Integer32,
extremeMinorVersion Integer32,
extremeBuildNumber Integer32,
extremeTechnologyReleaseNumber Integer32,
extremeSustainingReleaseNumber Integer32,
extremeBranchRevisionNumber Integer32,
extremeImageType INTEGER,
extremeImageDescription DisplayString,
extremeImageSecurity INTEGER,
extremePatchVersion Integer32
}
extremeImageNumber OBJECT-TYPE
SYNTAX INTEGER {
cur(0),
pri(1),
sec(2),
curr(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique integer identifying the particular software
image."
::= { extremeImageEntry 1 }
extremeMajorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ExtremeWare Release Major Version."
::= { extremeImageEntry 2 }
extremeSubMajorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The ExtremeWare Release Sub-major Version."
::= { extremeImageEntry 3 }
extremeMinorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ExtremeWare Release Minor Version."
::= { extremeImageEntry 4 }
extremeBuildNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ExtremeWare Build Number."
::= { extremeImageEntry 5 }
extremeTechnologyReleaseNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Technology Release version. This value is zero for
all but TR releases."
::= { extremeImageEntry 6 }
extremeSustainingReleaseNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Sustaining Release number for the ExtremeWare version."
::= { extremeImageEntry 7 }
extremeBranchRevisionNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The incremental build on specified branch."
::= { extremeImageEntry 8 }
extremeImageType OBJECT-TYPE
SYNTAX INTEGER {
trunk(0),
branch(1),
patch(2),
technology(3),
beta(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The branch type from which the image was built."
::= { extremeImageEntry 9 }
extremeImageDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique string that can be used to identify the specific patch,
technology, or development branch release."
::= { extremeImageEntry 10 }
extremeImageSecurity OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
nossh(1),
ssh(2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Indicates whether image was built with ssh. This object
is deprecated, the ssh capability can be obtained from
the extremeImageSshCapability of the ImageFeatureTable"
::= { extremeImageEntry 11 }
extremePatchVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ExtremeWare Release Patch Version."
::= { extremeImageEntry 12 }
extremeImageFeatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeImageFeatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about the software features."
::= { extremeSystemCommon 35 }
extremeImageFeatureEntry OBJECT-TYPE
SYNTAX ExtremeImageFeatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing information about software features."
INDEX { extremeImageFeatureNumber }
::= { extremeImageFeatureTable 1 }
ExtremeImageFeatureEntry ::= SEQUENCE {
extremeImageFeatureNumber INTEGER,
extremeImageSshCapability INTEGER,
extremeImageUAACapability INTEGER
}
extremeImageFeatureNumber OBJECT-TYPE
SYNTAX INTEGER {
cur(0),
pri(1),
sec(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique integer identifying the particular software
image."
::= { extremeImageFeatureEntry 1 }
extremeImageSshCapability OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
nossh(1),
ssh(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether image has ssh capability."
::= { extremeImageFeatureEntry 2 }
extremeImageUAACapability OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
nouaa(1),
uaa(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether image has Wireless(UAA) components."
::= { extremeImageFeatureEntry 3 }
extremeSystemPowerState OBJECT-TYPE
SYNTAX INTEGER {
computing(1),
sufficientButNotRedundantPower(2),
redundantPowerAvailable(3),
insufficientPower(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of power available."
::= { extremeSystemCommon 36 }
extremeBootTime OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The boot time expressed in standard time_t value.
When interpreted as an absolute time value, it
represents the number of seconds elapsed since 00:00:00
on January 1, 1970, Coordinated Universal Time (UTC)"
::= {extremeSystemCommon 37}
---------------------------------------------------------------------------
-- Objects specific to Chassis products
extremeChassisGroup OBJECT IDENTIFIER ::= { extremeSystem 2}
extremeMasterMSMSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The extremeSlotNumber of the master MSM module."
::= { extremeChassisGroup 1 }
extremeChassisPortsPerSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of ports that can be accomodated
in a single slot. This number would change to accomodate
blades with higher port density than current ones."
::= { extremeChassisGroup 3 }
extremeSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each slot in the
chassis."
::= { extremeChassisGroup 2 }
extremeSlotEntry OBJECT-TYPE
SYNTAX ExtremeSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing information about the module in
each slot of the chassis."
INDEX { extremeSlotNumber }
::= { extremeSlotTable 1 }
ExtremeSlotEntry ::= SEQUENCE {
extremeSlotNumber Integer32,
extremeSlotName DisplayString,
extremeSlotModuleConfiguredType INTEGER,
extremeSlotModuleInsertedType INTEGER,
extremeSlotModuleState INTEGER,
extremeSlotModuleSerialNumber DisplayString
}
extremeSlotNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique integer identifying the particular slot
in the chassis."
::= { extremeSlotEntry 1 }
extremeSlotName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A name identifying the particular slot in the chassis."
::= { extremeSlotEntry 2 }
extremeSlotModuleConfiguredType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
fe32(2),
g4x(3),
g6x(4),
fe32fx(5),
f48ti(7),
g8xi(8),
g8ti(9),
g12sxi(10),
g12ti(11),
fm32t(21),
gm4x(22),
gm4sx(23),
gm4t(24),
wdm8(25),
fm24f(26),
fm24sf(27),
fm24te(28),
f96ti(29),
wdm4(30),
f32fi(31),
tenGig(32),
tenGigLR(33),
g16x3(34),
g24t3(35),
gm16x3(36),
gm16t3(37),
fm8v(50), -- vdsl blade
wm4t1(51), -- 4port t1
wm4t3(52), -- 4port t3
wm1t3(53), -- 1port t3
wm4e1(54), -- 4port e1
p3c(101),
p12c(102),
arm(103),
mpls(104),
sma(105),
p48c(106),
a3c(107),
a12c(108),
pxm(200),
msm1(203),
msm1xl(204),
g60t(400),
g60x(401),
teng6x(402),
msm-g8x(414),
g8x(415),
g48t(416),
g48p(417),
g24x(418),
teng4x(419),
teng2x(420),
g20x(421),
teng2h(422),
msm5(425),
msm5r(426),
gm20t(427),
gm20xt(428),
gm20xtr(429),
xm2x(430),
xm2xr(431),
msm6r(432),
g48te(433),
g48ta(434),
g48pe(435),
g48x(437),
msm-48(447),
teng4ca(448),
teng4xa(449),
xm2hr(469)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured module type for the given slot.
At startup, the module-type is none(1). It is
possible to configure the module-type even if there
is no module in the slot. If the current module in the
slot is different than the requested configured module-type,
then the current configuration for the module is erased and
the card will be restarted. The new configured module-type
will be recorded. Since the configured module type is different
than the actual module type, a moduleMismatch trap will be sent,
and the extremeSlotModuleState for that module will show a
mismatch(3). Setting this variable to none(1) will clear the
previously assigned module-type of this slot, and all
configuration information related to the slot will be erased."
::= { extremeSlotEntry 3 }
extremeSlotModuleInsertedType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
fe32(2),
g4x(3),
g6x(4),
fe32fx(5),
msm(6),
f48ti(7),
g8xi(8),
g8ti(9),
g12sxi(10),
g12ti(11),
msm64i(18),
alpine3808(19),
alpine3804(20),
fm32t(21),
gm4x(22),
gm4sx(23),
gm4t(24),
wdm8(25),
fm24f(26),
fm24sf(27),
fm24te(28),
f96ti(29),
wdm4(30),
f32fi(31),
tenGig(32),
tenGigLR(33),
g16x3(34),
g24t3(35),
gm16x3(36),
gm16t3(37),
fm8v(50), -- vdsl blade
wm4t1(51), -- 4port t1
wm4t3(52), -- 4port t3
wm1t3(53), -- 1port t3
wm4e1(54), -- 4port e1
alpine3802(55),
p3c(101),
p12c(102),
arm(103),
mpls(104),
sma(105),
p48c(106),
a3c(107),
a12c(108),
pxm(200),
msm3(202),
msm1(203),
msm1xl(204),
g60t(400),
g60x(401),
teng6x(402),
msm-g8x(414),
g8x(415),
g48t(416),
g48p(417),
g24x(418),
teng4x(419),
teng2x(420),
g20x(421),
teng2h(422),
msm5(425),
msm5r(426),
gm20t(427),
gm20xt(428),
gm20xtr(429),
xm2x(430), -- 10G2X
xm2xr(431), -- 10G2XR
msm6r(432),
g48te(433),
g48ta(434),
g48pe(435),
g48x(437),
msm-48(447),
teng4ca(448),
teng4xa(449),
xm2hr(469)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module type inserted into the slot. It is possible
to have a slot inserted into the slot even though
extremeSlotConfiguredType is none(1)."
::= { extremeSlotEntry 4 }
extremeSlotModuleState OBJECT-TYPE
SYNTAX INTEGER {
notPresent(1),
testing(2),
mismatch(3),
failed(4),
operational(5),
powerdown(6),
unknown(7),
present(8),
poweron(9),
post(10),
downloading(11),
booting(12),
offline(13),
initializing(14),
invalid(100)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the module inserted in this slot."
::= { extremeSlotEntry 5 }
extremeSlotModuleSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the module inserted in this slot."
::= { extremeSlotEntry 6 }
extremeSystemHealthCheck OBJECT IDENTIFIER
::= { extremeSystem 3 }
extremeHealthCheckErrorType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
cpuPacket(2),
backplane(3),
hardwareFail(4),
pbusChecksum(5)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The error reported in the system health check trap"
::= { extremeSystemHealthCheck 1 }
extremeHealthCheckAction OBJECT-TYPE
SYNTAX INTEGER {
syslogOnly(1),
healthCheckTrap(2),
ioModuleDown(3),
systemDown(4),
autoRecovery(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The action/alarm level configured for health check."
::= { extremeSystemHealthCheck 2 }
extremeHealthCheckMaxRetries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of times a module restart will be attempted if it fails.
If extremeHealthCheckAction is not autorecovery(5), then this value is zero."
::= { extremeSystemHealthCheck 3 }
-- ===========================================================================
extremeSystemThresholds OBJECT IDENTIFIER
::= { extremeSystem 4 }
extremeCpuUtilRisingThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Rising threshold for CPU Aggregation utilization trap"
::= { extremeSystemThresholds 1 }
extremeCpuTaskUtilPair OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS deprecated
DESCRIPTION
"TaskName/CPU_% Util pair reported in CPU Utilization trap"
::= { extremeSystemThresholds 2 }
extremeSystemNotifications OBJECT IDENTIFIER ::= { extremeSystem 6 }
extremeSystemTrapsPrefix OBJECT IDENTIFIER ::= { extremeSystemNotifications 0 }
extremeSystemPowerStatus NOTIFICATION-TYPE
OBJECTS { sysDescr, extremeSystemPowerState }
STATUS current
DESCRIPTION
"Change in status of System Power
The trap will not be generated for discovering state."
::= { extremeSystemTrapsPrefix 1 }
END
-- ################################################################################