snmp_mib_archive/DOCS-TEST-MIB.my
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

179 lines
6.4 KiB
Plaintext

-- *****************************************************************
-- DOCS-TEST-MIB.my: Data Over Cable Test MIB file
--
-- Aug 2003 Sajeev Jos
--
-- This MIB is from SP-TestMIBv2.0-D02-030530
--
-- Copyright (c) 1999-2003, 2007-2008 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
DOCS-TEST-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
-- do not import BITS,
Integer32,
enterprises
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
TruthValue
FROM SNMPv2-TC
OBJECT-GROUP,
MODULE-COMPLIANCE
FROM SNMPv2-CONF;
-- These are the defined Cablelabs OID paths. Not all are needed for the Test MIB,
-- but included here for sake of completeness.
cableLabs OBJECT IDENTIFIER ::= { enterprises 4491 }
clabFunction OBJECT IDENTIFIER ::= { cableLabs 1 }
clabFuncMib2 OBJECT IDENTIFIER ::= { clabFunction 1 }
clabFuncProprietary OBJECT IDENTIFIER ::= { clabFunction 2 }
clabProject OBJECT IDENTIFIER ::= { cableLabs 2 }
clabProjDocsis OBJECT IDENTIFIER ::= { clabProject 1 }
clabProjPacketCable OBJECT IDENTIFIER ::= { clabProject 2 }
clabProjOpenCable OBJECT IDENTIFIER ::= { clabProject 3 }
clabProjCableHome OBJECT IDENTIFIER ::= { clabProject 4 }
docsTestMIB MODULE-IDENTITY
LAST-UPDATED "0203150000Z" -- March 15, 2002
ORGANIZATION "DOCSIS 2.0 ATP Working Group"
CONTACT-INFO
" David Raftus
Postal: Terayon Canada Ltd
340 Terry Fox Drive, Suite 202
Ottawa Ontario
Canada
Phone: +1 613 592 1052
E-mail: david.raftus@terayon.com
DOCSIS 2.0 ATP Working Group
General Discussion: docsis-20@cablelabs.com,
docsis-20-atp@cablelabs.com"
DESCRIPTION
"This is the MIB Module supporting programmable test features
for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem
Termination Systems (CMTS)."
-- 4491 is the IANA Cablelabs enterprise number
::= { clabProjDocsis 12 }
-- Textual Conventions
-- none required yet - dave - leave as a placeholder
-- Mapping path to the test mib.
--
docsTestMibObjects OBJECT IDENTIFIER ::= { docsTestMIB 1 }
docsTestBaseObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 1 }
docsTestSetupObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 2 }
--
-- docsTestBaseObjects
--
-- These objects indicate the capability and current status of the
-- programmable test features on the CM/CMTS.
--
docsTestCapability OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ability of this device to support the
programmable features identified by the TYPE field from
the CM/CMTS TLV table in [17].
Each octet within this octet string represents eight tests.
For example, the first octet represents tests one through eight
(with the msb representing test one) as identified by the TYPE
field."
::= { docsTestBaseObjects 1 }
docsTestStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current operating status of tests initiated
through the docsTestSetupObjects. The octet representation is
identical to that used by docsTestCapability. A bit representation
of one indicates that a test is currently active, while zero
indicates the test is inactive or has completed."
::= { docsTestBaseObjects 2 }
--
-- docsTestSetupObjects
--
-- These objects setup the test parameters ands initiate the test.
docsTestType OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Corresponds to the TYPE field from the CM/CMTS TLV Table
in [17]. The default value of zero indicates
no test has yet been initiated.
A WrongValueError should be returned in response to a write
request for a test not supported by the device. A read request
will return the docsTestType value last successfully written,
whether that test is active or inactive."
DEFVAL { 0 }
::= { docsTestSetupObjects 1 }
docsTestData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OCTET STRING length and value correspond to the
LENGTH and VALUE fields from the CM/CMTS TLV
Table in [17]. A read request will return the
docsTestData value last successfully written, whether that test
is active or inactive."
::= { docsTestSetupObjects 2 }
docsTestEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to initiate or stop the tests setup through the docsTestType
and docsTestData objects.
A CommitFailedError should be returned in response to a TRUE
Write request if the values in docsTestType and docsTestData are
incompatible, or a test could not be initiated for any other
reason."
::= { docsTestSetupObjects 3 }
-- Compliance statements
docsTestConformance OBJECT IDENTIFIER ::= { docsTestMIB 2 }
docsTestCompliances OBJECT IDENTIFIER ::= { docsTestConformance 1 }
docsTestGroups OBJECT IDENTIFIER ::= { docsTestConformance 2 }
docsTestBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for devices that implement
the DOCSIS compliant programmable test features."
MODULE -- docsTestMib
-- unconditionally mandatory groups
MANDATORY-GROUPS { docsTestGroup }
::= { docsTestCompliances 1 }
docsTestGroup OBJECT-GROUP
OBJECTS {
docsTestCapability,
docsTestStatus,
docsTestType,
docsTestData,
docsTestEnable
}
STATUS current
DESCRIPTION
"Group of objects implemented in both Cable Modems and
Cable Modem Termination Systems."
::= { docsTestGroups 1 }