mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-17 16:03:04 +00:00
758 lines
22 KiB
Plaintext
758 lines
22 KiB
Plaintext
-- *******************************************************************
|
|
-- CISCO-WAN-TRAP-VARS-MIB
|
|
--
|
|
-- MIB Containing Objects Which are used only in trap definitions.
|
|
--
|
|
-- November 2002, Yizhong Shen
|
|
--
|
|
-- Copyright(c) 1999-2002 by Cisco Systems,Inc.
|
|
-- All Rights Reserved.
|
|
-- ********************************************************************
|
|
|
|
CISCO-WAN-TRAP-VARS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,Integer32,
|
|
Unsigned32 FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
AutonomousType,
|
|
DisplayString FROM SNMPv2-TC
|
|
ciscoWan FROM CISCOWAN-SMI;
|
|
|
|
ciscoWanTrapVarsMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200211260000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-wanatm@cisco.com"
|
|
DESCRIPTION
|
|
"This MIB module is for Supporting Varbinds used only
|
|
in trap defintions. The NMS applications should not
|
|
depend on the implementation of these objects.The
|
|
SNMP Requests(GET,GET-NEXT) may not be valid for
|
|
these objects."
|
|
|
|
REVISION "200211260000Z"
|
|
DESCRIPTION "Added following objects:
|
|
- cwTrapSecondIndex
|
|
- cwTrapThirdIndex
|
|
"
|
|
|
|
REVISION "200207170000Z"
|
|
DESCRIPTION "a) Importing Unsigned32 from SNMPv2-SMI.
|
|
b) Add cwTrapVarLength, cwTrapAtmAdressType
|
|
and cwTrapReference.
|
|
c) Add cwTrapSecondIndex and cwTrapThirdIndex"
|
|
|
|
REVISION "200111070000Z"
|
|
DESCRIPTION "Added following objects:
|
|
cwTrapCardRole,
|
|
cwTrapSctCardType, cwTrapSctType, cwTrapSctId and
|
|
cwTrapSctMajorVersion."
|
|
|
|
REVISION "200111060000Z"
|
|
DESCRIPTION "Added following objects:
|
|
cwTrapPhysicalContainer,
|
|
cwTrapPhysicalUnit."
|
|
|
|
REVISION "200107260000Z"
|
|
DESCRIPTION "Add cwTrapDisplayString"
|
|
|
|
REVISION "199905210000Z"
|
|
DESCRIPTION "Initial version of the MIB"
|
|
|
|
::= { ciscoWan 5 }
|
|
|
|
cwTrapVarMIBObjects OBJECT IDENTIFIER ::= { ciscoWanTrapVarsMIB 1 }
|
|
|
|
cwTrapVars OBJECT IDENTIFIER ::= { cwTrapVarMIBObjects 1 }
|
|
|
|
cwTrapIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object containing the value which can be used
|
|
for indexing to any table."
|
|
::= { cwTrapVars 1 }
|
|
|
|
cwTrapSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..64)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the slot number of the module."
|
|
::= { cwTrapVars 2 }
|
|
|
|
cwTrapPhysicalVendorType OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the entPhysicalVendorType value
|
|
for the physical entity."
|
|
::= { cwTrapVars 3 }
|
|
|
|
cwTrapLineModuleNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..4)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value for entPhysicalParentRelPos
|
|
object for line modules."
|
|
::= { cwTrapVars 4 }
|
|
|
|
cwTrapOctetString OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..1024))
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the octet string value."
|
|
::= { cwTrapVars 5 }
|
|
|
|
cwTrapDisplayString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the display string value."
|
|
::= { cwTrapVars 6 }
|
|
|
|
cwTrapPhysicalContainer OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the container(parent unit number) number of
|
|
an entity in entPhysicalTable. This object contains the value
|
|
for the following entities:
|
|
Fan Tray
|
|
Power Supply Tray/Group.
|
|
If it contains value zero, then this object is not applicable
|
|
for the entity identified by cwTrapPhysicalUnit."
|
|
::= { cwTrapVars 7 }
|
|
|
|
cwTrapPhysicalUnit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the physical unit number(Relative Position)
|
|
of the physical entity. The physical unit number depends upon
|
|
the value specified in cwTrapPhysicalContainer object."
|
|
::= { cwTrapVars 8 }
|
|
|
|
cwTrapCardRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
t1(1),
|
|
e1(2),
|
|
t3(3),
|
|
e3(4)
|
|
}
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the card role change to
|
|
T1 from E1, or T3 from E3, vice versa. In case of a card
|
|
with multiple roles, this object only indicates the changeable
|
|
role swap between T1 and E1, or T3 and E3."
|
|
::= { cwTrapVars 9 }
|
|
|
|
cwTrapSctCardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
axsm (1),
|
|
axsme (2),
|
|
pxm1e (3),
|
|
hsfr (4)
|
|
}
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used only for traps and represents the
|
|
cwSctCardType object in CISCO-WAN-SCT-MGMT-MIB.my."
|
|
::= { cwTrapVars 10 }
|
|
|
|
cwTrapSctType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
portSct(1),
|
|
cardSct(2)
|
|
}
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used only for traps and represents the
|
|
cwSctType object in CISCO-WAN-SCT-MGMT-MIB.my."
|
|
::= { cwTrapVars 11 }
|
|
|
|
cwTrapSctId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used only for traps and represents the cwSctId
|
|
object in CISCO-WAN-SCT-MGMT-MIB.my."
|
|
::= { cwTrapVars 12 }
|
|
|
|
cwTrapSctMajorVersion OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..65535)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used only for traps and represents the
|
|
cwSctMajorVersion object in CISCO-WAN-SCT-MGMT-MIB.my."
|
|
::= { cwTrapVars 13 }
|
|
|
|
cwTrapVarLength OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..1024)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is an object used only for traps and contains
|
|
a value for the length of another object.
|
|
For instance, this can be the length of
|
|
an address."
|
|
::= { cwTrapVars 14 }
|
|
|
|
cwTrapAtmAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
e164(3),
|
|
nsap(8)
|
|
}
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used only for traps and represents
|
|
the type of an ATM addresses."
|
|
::= { cwTrapVars 15 }
|
|
|
|
cwTrapReference OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
-- MAX-ACCESS accessible-for-notify
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used only for traps and represents an object
|
|
of the same SYNTAX. This object is used in place of:
|
|
a) 'cwapReference' in CISCO-WAN-ATM-PARTY-MIB.my."
|
|
::= { cwTrapVars 16 }
|
|
|
|
cwTrapSecondIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object containing the value which can be used
|
|
for indexing to any table."
|
|
::= { cwTrapVars 17 }
|
|
|
|
cwTrapThirdIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object containing the value which can be used
|
|
for indexing to any table."
|
|
::= { cwTrapVars 18 }
|
|
|
|
|
|
-- conformance information
|
|
cwTrapVarsMIBConformance OBJECT IDENTIFIER ::= { ciscoWanTrapVarsMIB 2 }
|
|
|
|
cwTrapVarsMIBCompliances OBJECT IDENTIFIER ::= { cwTrapVarsMIBConformance 1 }
|
|
cwTrapVarsMIBGroups OBJECT IDENTIFIER ::= { cwTrapVarsMIBConformance 2 }
|
|
|
|
-- compliance statements
|
|
cwTrapVarsCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated -- replaced by cwTrapVarsCompliance2
|
|
DESCRIPTION
|
|
"The compliance statement for cwTrapVarsGroup."
|
|
MODULE -- this module
|
|
|
|
GROUP cwTrapVarsTrapGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is not mandatory for the agents
|
|
which does not use these objects in traps.
|
|
"
|
|
|
|
OBJECT cwTrapIndex
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSlotNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalVendorType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapLineModuleNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
OBJECT cwTrapOctetString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
::= { cwTrapVarsMIBCompliances 1 }
|
|
|
|
cwTrapVarsCompliance2 MODULE-COMPLIANCE
|
|
STATUS deprecated -- replaced by cwTrapVarsCompliance3
|
|
DESCRIPTION
|
|
"The compliance statement for cwTrapVarsGroup."
|
|
MODULE -- this module
|
|
|
|
GROUP cwTrapVarsTrapGroup2
|
|
DESCRIPTION
|
|
"Implementation of this group is not mandatory for the agents
|
|
which does not use these objects in traps.
|
|
"
|
|
|
|
OBJECT cwTrapIndex
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSlotNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalVendorType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapLineModuleNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapOctetString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapDisplayString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
::= { cwTrapVarsMIBCompliances 2 }
|
|
|
|
cwTrapVarsCompliance3 MODULE-COMPLIANCE
|
|
STATUS deprecated -- replaced by cwTrapVarsCompliance4
|
|
DESCRIPTION
|
|
"The compliance statement for cwTrapVarsGroup."
|
|
MODULE -- this module
|
|
|
|
GROUP cwTrapVarsTrapGroup3
|
|
DESCRIPTION
|
|
"Implementation of this group is not mandatory for the agents
|
|
which does not use these objects in traps.
|
|
"
|
|
|
|
OBJECT cwTrapIndex
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSlotNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalVendorType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapLineModuleNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapOctetString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapDisplayString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalContainer
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalUnit
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
::= { cwTrapVarsMIBCompliances 3 }
|
|
|
|
|
|
cwTrapVarsCompliance4 MODULE-COMPLIANCE
|
|
STATUS deprecated -- replaced by cwTrapVarsCompliance5
|
|
DESCRIPTION
|
|
"The compliance statement for cwTrapVarsGroup."
|
|
MODULE -- this module
|
|
|
|
GROUP cwTrapVarsTrapGroup4
|
|
DESCRIPTION
|
|
"Implementation of this group is not mandatory for the agents
|
|
which does not use these objects in traps.
|
|
"
|
|
|
|
OBJECT cwTrapIndex
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSlotNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalVendorType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapLineModuleNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapOctetString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapDisplayString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalContainer
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalUnit
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapCardRole
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSctCardType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSctType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSctId
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSctMajorVersion
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
::= { cwTrapVarsMIBCompliances 4 }
|
|
|
|
cwTrapVarsCompliance5 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for cwTrapVarsGroup."
|
|
MODULE -- this module
|
|
|
|
GROUP cwTrapVarsTrapGroup5
|
|
DESCRIPTION
|
|
"Implementation of this group is not mandatory for the agents
|
|
which does not use these objects in traps.
|
|
"
|
|
|
|
OBJECT cwTrapIndex
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSlotNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalVendorType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapLineModuleNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapOctetString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapDisplayString
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalContainer
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapPhysicalUnit
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapCardRole
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSctCardType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSctType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSctId
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSctMajorVersion
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapVarLength
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapAtmAddressType
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapReference
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapSecondIndex
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
OBJECT cwTrapThirdIndex
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Read and write access is not required.This Object is
|
|
used only in trap varbinds."
|
|
|
|
|
|
::= { cwTrapVarsMIBCompliances 5 }
|
|
|
|
|
|
-- Units of conformance
|
|
|
|
cwTrapVarsTrapGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwTrapIndex,
|
|
cwTrapSlotNumber,
|
|
cwTrapPhysicalVendorType,
|
|
cwTrapLineModuleNumber,
|
|
cwTrapOctetString
|
|
}
|
|
STATUS deprecated -- replaced by cwTrapVarsTrapGroup2
|
|
DESCRIPTION
|
|
"The collection of objects which are used only
|
|
in trap varbinds."
|
|
::= { cwTrapVarsMIBGroups 1 }
|
|
|
|
cwTrapVarsTrapGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
cwTrapIndex,
|
|
cwTrapSlotNumber,
|
|
cwTrapPhysicalVendorType,
|
|
cwTrapLineModuleNumber,
|
|
cwTrapOctetString,
|
|
cwTrapDisplayString
|
|
}
|
|
STATUS deprecated -- replaced by cwTrapVarsTrapGroup3
|
|
DESCRIPTION
|
|
"The collection of objects which are used only
|
|
in trap varbinds."
|
|
::= { cwTrapVarsMIBGroups 2 }
|
|
|
|
cwTrapVarsTrapGroup3 OBJECT-GROUP
|
|
OBJECTS {
|
|
cwTrapIndex,
|
|
cwTrapSlotNumber,
|
|
cwTrapPhysicalVendorType,
|
|
cwTrapLineModuleNumber,
|
|
cwTrapOctetString,
|
|
cwTrapDisplayString,
|
|
cwTrapPhysicalContainer,
|
|
cwTrapPhysicalUnit
|
|
}
|
|
STATUS deprecated -- replaced by cwTrapVarsTrapGroup4
|
|
DESCRIPTION
|
|
"The collection of objects which are used only
|
|
in trap varbinds."
|
|
::= { cwTrapVarsMIBGroups 3 }
|
|
|
|
|
|
cwTrapVarsTrapGroup4 OBJECT-GROUP
|
|
OBJECTS {
|
|
cwTrapIndex,
|
|
cwTrapSlotNumber,
|
|
cwTrapPhysicalVendorType,
|
|
cwTrapLineModuleNumber,
|
|
cwTrapOctetString,
|
|
cwTrapDisplayString,
|
|
cwTrapPhysicalContainer,
|
|
cwTrapPhysicalUnit,
|
|
cwTrapCardRole,
|
|
cwTrapSctCardType,
|
|
cwTrapSctType,
|
|
cwTrapSctId,
|
|
cwTrapSctMajorVersion
|
|
}
|
|
STATUS deprecated -- replaced by cwTrapVarsTrapGroup5
|
|
DESCRIPTION
|
|
"The collection of objects which are used only
|
|
in trap varbinds."
|
|
::= { cwTrapVarsMIBGroups 4 }
|
|
|
|
cwTrapVarsTrapGroup5 OBJECT-GROUP
|
|
OBJECTS {
|
|
cwTrapIndex,
|
|
cwTrapSlotNumber,
|
|
cwTrapPhysicalVendorType,
|
|
cwTrapLineModuleNumber,
|
|
cwTrapOctetString,
|
|
cwTrapDisplayString,
|
|
cwTrapPhysicalContainer,
|
|
cwTrapPhysicalUnit,
|
|
cwTrapCardRole,
|
|
cwTrapSctCardType,
|
|
cwTrapSctType,
|
|
cwTrapSctId,
|
|
cwTrapSctMajorVersion,
|
|
cwTrapVarLength,
|
|
cwTrapAtmAddressType,
|
|
cwTrapReference,
|
|
cwTrapSecondIndex,
|
|
cwTrapThirdIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are used only
|
|
in trap varbinds."
|
|
::= { cwTrapVarsMIBGroups 5 }
|
|
|
|
END
|