-- CISCO-WAN-TRAP-VARS-MIB
--
-- MIB Containing Objects Which are used only in trap definitions.
--
-- November 2002, Yizhong Shen
--
-- Copyright(c) 1999-2002 by Cisco Systems,Inc.
-- All Rights Reserved.
-- ********************************************************************
CISCO-WAN-TRAP-VARS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,Integer32,
Unsigned32 FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
AutonomousType,
DisplayString FROM SNMPv2-TC
ciscoWan FROM CISCOWAN-SMI;
ciscoWanTrapVarsMIB MODULE-IDENTITY
LAST-UPDATED "200211260000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-wanatm@cisco.com"
DESCRIPTION
"This MIB module is for Supporting Varbinds used only
in trap defintions. The NMS applications should not
depend on the implementation of these objects.The
SNMP Requests(GET,GET-NEXT) may not be valid for
these objects."
REVISION "200211260000Z"
DESCRIPTION "Added following objects:
- cwTrapSecondIndex
- cwTrapThirdIndex
"
REVISION "200207170000Z"
DESCRIPTION "a) Importing Unsigned32 from SNMPv2-SMI.
b) Add cwTrapVarLength, cwTrapAtmAdressType
and cwTrapReference.
c) Add cwTrapSecondIndex and cwTrapThirdIndex"
REVISION "200111070000Z"
DESCRIPTION "Added following objects:
cwTrapCardRole,
cwTrapSctCardType, cwTrapSctType, cwTrapSctId and
cwTrapSctMajorVersion."
REVISION "200111060000Z"
DESCRIPTION "Added following objects:
cwTrapPhysicalContainer,
cwTrapPhysicalUnit."
REVISION "200107260000Z"
DESCRIPTION "Add cwTrapDisplayString"
REVISION "199905210000Z"
DESCRIPTION "Initial version of the MIB"
::= { ciscoWan 5 }
cwTrapVarMIBObjects OBJECT IDENTIFIER ::= { ciscoWanTrapVarsMIB 1 }
cwTrapVars OBJECT IDENTIFIER ::= { cwTrapVarMIBObjects 1 }
cwTrapIndex OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object containing the value which can be used
for indexing to any table."
::= { cwTrapVars 1 }
cwTrapSlotNumber OBJECT-TYPE
SYNTAX Integer32(1..64)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the slot number of the module."
::= { cwTrapVars 2 }
cwTrapPhysicalVendorType OBJECT-TYPE
SYNTAX AutonomousType
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the entPhysicalVendorType value
for the physical entity."
::= { cwTrapVars 3 }
cwTrapLineModuleNumber OBJECT-TYPE
SYNTAX Integer32(1..4)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the value for entPhysicalParentRelPos
object for line modules."
::= { cwTrapVars 4 }
cwTrapOctetString OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1024))
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the octet string value."
::= { cwTrapVars 5 }
cwTrapDisplayString OBJECT-TYPE
SYNTAX DisplayString
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the display string value."
::= { cwTrapVars 6 }
cwTrapPhysicalContainer OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the container(parent unit number) number of
an entity in entPhysicalTable. This object contains the value
for the following entities:
Fan Tray
Power Supply Tray/Group.
If it contains value zero, then this object is not applicable
for the entity identified by cwTrapPhysicalUnit."
::= { cwTrapVars 7 }
cwTrapPhysicalUnit OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the physical unit number(Relative Position)
of the physical entity. The physical unit number depends upon
the value specified in cwTrapPhysicalContainer object."
::= { cwTrapVars 8 }
cwTrapCardRole OBJECT-TYPE
SYNTAX INTEGER {
t1(1),
e1(2),
t3(3),
e3(4)
}
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the card role change to
T1 from E1, or T3 from E3, vice versa. In case of a card
with multiple roles, this object only indicates the changeable
role swap between T1 and E1, or T3 and E3."
::= { cwTrapVars 9 }
cwTrapSctCardType OBJECT-TYPE
SYNTAX INTEGER {
axsm (1),
axsme (2),
pxm1e (3),
hsfr (4)
}
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used only for traps and represents the
cwSctCardType object in CISCO-WAN-SCT-MGMT-MIB.my."
::= { cwTrapVars 10 }
cwTrapSctType OBJECT-TYPE
SYNTAX INTEGER {
portSct(1),
cardSct(2)
}
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used only for traps and represents the
cwSctType object in CISCO-WAN-SCT-MGMT-MIB.my."
::= { cwTrapVars 11 }
cwTrapSctId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used only for traps and represents the cwSctId
object in CISCO-WAN-SCT-MGMT-MIB.my."
::= { cwTrapVars 12 }
cwTrapSctMajorVersion OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used only for traps and represents the
cwSctMajorVersion object in CISCO-WAN-SCT-MGMT-MIB.my."
::= { cwTrapVars 13 }
cwTrapVarLength OBJECT-TYPE
SYNTAX Unsigned32(1..1024)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an object used only for traps and contains
a value for the length of another object.
For instance, this can be the length of
an address."
::= { cwTrapVars 14 }
cwTrapAtmAddressType OBJECT-TYPE
SYNTAX INTEGER{
e164(3),
nsap(8)
}
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used only for traps and represents
the type of an ATM addresses."
::= { cwTrapVars 15 }
cwTrapReference OBJECT-TYPE
SYNTAX Integer32(1..65535)
-- MAX-ACCESS accessible-for-notify
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used only for traps and represents an object
of the same SYNTAX. This object is used in place of:
a) 'cwapReference' in CISCO-WAN-ATM-PARTY-MIB.my."
::= { cwTrapVars 16 }
cwTrapSecondIndex OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object containing the value which can be used
for indexing to any table."
::= { cwTrapVars 17 }
cwTrapThirdIndex OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object containing the value which can be used
for indexing to any table."
::= { cwTrapVars 18 }
-- conformance information
cwTrapVarsMIBConformance OBJECT IDENTIFIER ::= { ciscoWanTrapVarsMIB 2 }
cwTrapVarsMIBCompliances OBJECT IDENTIFIER ::= { cwTrapVarsMIBConformance 1 }
cwTrapVarsMIBGroups OBJECT IDENTIFIER ::= { cwTrapVarsMIBConformance 2 }
-- compliance statements
cwTrapVarsCompliance MODULE-COMPLIANCE
STATUS deprecated -- replaced by cwTrapVarsCompliance2
DESCRIPTION
"The compliance statement for cwTrapVarsGroup."
MODULE -- this module
GROUP cwTrapVarsTrapGroup
DESCRIPTION
"Implementation of this group is not mandatory for the agents
which does not use these objects in traps.
"
OBJECT cwTrapIndex
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSlotNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalVendorType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapLineModuleNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapOctetString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
::= { cwTrapVarsMIBCompliances 1 }
cwTrapVarsCompliance2 MODULE-COMPLIANCE
STATUS deprecated -- replaced by cwTrapVarsCompliance3
DESCRIPTION
"The compliance statement for cwTrapVarsGroup."
MODULE -- this module
GROUP cwTrapVarsTrapGroup2
DESCRIPTION
"Implementation of this group is not mandatory for the agents
which does not use these objects in traps.
"
OBJECT cwTrapIndex
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSlotNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalVendorType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapLineModuleNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapOctetString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapDisplayString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
::= { cwTrapVarsMIBCompliances 2 }
cwTrapVarsCompliance3 MODULE-COMPLIANCE
STATUS deprecated -- replaced by cwTrapVarsCompliance4
DESCRIPTION
"The compliance statement for cwTrapVarsGroup."
MODULE -- this module
GROUP cwTrapVarsTrapGroup3
DESCRIPTION
"Implementation of this group is not mandatory for the agents
which does not use these objects in traps.
"
OBJECT cwTrapIndex
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSlotNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalVendorType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapLineModuleNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapOctetString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapDisplayString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalContainer
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalUnit
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
::= { cwTrapVarsMIBCompliances 3 }
cwTrapVarsCompliance4 MODULE-COMPLIANCE
STATUS deprecated -- replaced by cwTrapVarsCompliance5
DESCRIPTION
"The compliance statement for cwTrapVarsGroup."
MODULE -- this module
GROUP cwTrapVarsTrapGroup4
DESCRIPTION
"Implementation of this group is not mandatory for the agents
which does not use these objects in traps.
"
OBJECT cwTrapIndex
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSlotNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalVendorType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapLineModuleNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapOctetString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapDisplayString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalContainer
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalUnit
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapCardRole
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSctCardType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSctType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSctId
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSctMajorVersion
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
::= { cwTrapVarsMIBCompliances 4 }
cwTrapVarsCompliance5 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for cwTrapVarsGroup."
MODULE -- this module
GROUP cwTrapVarsTrapGroup5
DESCRIPTION
"Implementation of this group is not mandatory for the agents
which does not use these objects in traps.
"
OBJECT cwTrapIndex
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSlotNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalVendorType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapLineModuleNumber
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapOctetString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapDisplayString
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalContainer
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapPhysicalUnit
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapCardRole
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSctCardType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSctType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSctId
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSctMajorVersion
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapVarLength
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapAtmAddressType
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapReference
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapSecondIndex
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
OBJECT cwTrapThirdIndex
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required.This Object is
used only in trap varbinds."
::= { cwTrapVarsMIBCompliances 5 }
-- Units of conformance
cwTrapVarsTrapGroup OBJECT-GROUP
OBJECTS {
cwTrapIndex,
cwTrapSlotNumber,
cwTrapPhysicalVendorType,
cwTrapLineModuleNumber,
cwTrapOctetString
}
STATUS deprecated -- replaced by cwTrapVarsTrapGroup2
DESCRIPTION
"The collection of objects which are used only
in trap varbinds."
::= { cwTrapVarsMIBGroups 1 }
cwTrapVarsTrapGroup2 OBJECT-GROUP
OBJECTS {
cwTrapIndex,
cwTrapSlotNumber,
cwTrapPhysicalVendorType,
cwTrapLineModuleNumber,
cwTrapOctetString,
cwTrapDisplayString
}
STATUS deprecated -- replaced by cwTrapVarsTrapGroup3
DESCRIPTION
"The collection of objects which are used only
in trap varbinds."
::= { cwTrapVarsMIBGroups 2 }
cwTrapVarsTrapGroup3 OBJECT-GROUP
OBJECTS {
cwTrapIndex,
cwTrapSlotNumber,
cwTrapPhysicalVendorType,
cwTrapLineModuleNumber,
cwTrapOctetString,
cwTrapDisplayString,
cwTrapPhysicalContainer,
cwTrapPhysicalUnit
}
STATUS deprecated -- replaced by cwTrapVarsTrapGroup4
DESCRIPTION
"The collection of objects which are used only
in trap varbinds."
::= { cwTrapVarsMIBGroups 3 }
cwTrapVarsTrapGroup4 OBJECT-GROUP
OBJECTS {
cwTrapIndex,
cwTrapSlotNumber,
cwTrapPhysicalVendorType,
cwTrapLineModuleNumber,
cwTrapOctetString,
cwTrapDisplayString,
cwTrapPhysicalContainer,
cwTrapPhysicalUnit,
cwTrapCardRole,
cwTrapSctCardType,
cwTrapSctType,
cwTrapSctId,
cwTrapSctMajorVersion
}
STATUS deprecated -- replaced by cwTrapVarsTrapGroup5
DESCRIPTION
"The collection of objects which are used only
in trap varbinds."
::= { cwTrapVarsMIBGroups 4 }
cwTrapVarsTrapGroup5 OBJECT-GROUP
OBJECTS {
cwTrapIndex,
cwTrapSlotNumber,
cwTrapPhysicalVendorType,
cwTrapLineModuleNumber,
cwTrapOctetString,
cwTrapDisplayString,
cwTrapPhysicalContainer,
cwTrapPhysicalUnit,
cwTrapCardRole,
cwTrapSctCardType,
cwTrapSctType,
cwTrapSctId,
cwTrapSctMajorVersion,
cwTrapVarLength,
cwTrapAtmAddressType,
cwTrapReference,
cwTrapSecondIndex,
cwTrapThirdIndex
}
STATUS current
DESCRIPTION
"The collection of objects which are used only
in trap varbinds."
::= { cwTrapVarsMIBGroups 5 }
END