mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-17 16:03:04 +00:00
1910 lines
71 KiB
Plaintext
1910 lines
71 KiB
Plaintext
-- *****************************************************************
|
|
-- CISCO-MODEM-MGMT-MIB.my: Cisco Modem Management MIB file
|
|
--
|
|
-- January 1996, Viet Nguyen
|
|
--
|
|
-- Copyright (c) 1996-1998, 1999, 2000, 2001, 2005 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
CISCO-MODEM-MGMT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE,
|
|
OBJECT-TYPE,
|
|
Integer32,
|
|
Gauge32,
|
|
Counter32,
|
|
TimeTicks,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TruthValue,
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoModemMgmtMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200512060000Z" -- Dec 06,2005
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-snmp@cisco.com"
|
|
DESCRIPTION
|
|
"This MIB module provides modem call related data for
|
|
tracking the progress and status of a call."
|
|
|
|
REVISION "200512060000Z"
|
|
DESCRIPTION
|
|
"Imported Unsigned32 from SNMPv2-SMI instead of CISCO-TC"
|
|
|
|
REVISION "200112011200Z" -- Dec 01,2001 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Added one more comment for cmTXAnalogSignalLevel"
|
|
|
|
REVISION "200110011200Z"
|
|
DESCRIPTION
|
|
"General cleanup"
|
|
|
|
REVISION "200004010000Z"
|
|
DESCRIPTION
|
|
"Added cmStateNotification and cmStateNotifyEnable"
|
|
|
|
REVISION "9812160000Z"
|
|
DESCRIPTION
|
|
"Added cmTotalCallDuration"
|
|
|
|
REVISION "9806180000Z"
|
|
DESCRIPTION
|
|
"Added the new enum values for cmDisconnectReason"
|
|
|
|
REVISION "9712220000Z"
|
|
DESCRIPTION
|
|
"Changed the modulation from v27 to v29."
|
|
|
|
REVISION "9710130000Z"
|
|
DESCRIPTION
|
|
"Added new compliance statement for as5300 and c3600."
|
|
|
|
REVISION "9707180000Z"
|
|
DESCRIPTION
|
|
"Added new MIB variables cmInitialTxLineConnections and
|
|
cmInitialRxLineConnections"
|
|
|
|
REVISION "9803090000Z"
|
|
DESCRIPTION
|
|
"Added the new enum values v90 and v27ter for
|
|
cmModulationSchemeUsed."
|
|
|
|
REVISION "9712160000Z"
|
|
DESCRIPTION
|
|
"Changed the modulation from v27 to v29."
|
|
|
|
REVISION "9705010000Z"
|
|
DESCRIPTION
|
|
"Added objects:
|
|
cmSystemModemsInUse
|
|
cmSystemModemsAvailable
|
|
cmSystemModemsUnavailable
|
|
cmSystemModemsOffline
|
|
cmSystemModemsDead"
|
|
|
|
REVISION "9704290000Z"
|
|
DESCRIPTION
|
|
"Changed the modulation from v29 to v27."
|
|
|
|
REVISION "9706110000Z"
|
|
DESCRIPTION
|
|
"DEFVAL update for cmSystemWatchdogTime,cmSystemStatusPollTime."
|
|
|
|
REVISION "9703210000Z"
|
|
DESCRIPTION
|
|
"New enum values added for cmModulationSchemeUsed."
|
|
|
|
REVISION "9703170000Z"
|
|
DESCRIPTION
|
|
"New enum values added for cmDisconnectReason."
|
|
|
|
REVISION "9601110000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { ciscoMgmt 47 }
|
|
|
|
ciscoModemMgmtMIBObjects OBJECT IDENTIFIER ::= { ciscoModemMgmtMIB 1 }
|
|
|
|
cmSystemInfo OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBObjects 1 }
|
|
cmGroupInfo OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBObjects 2 }
|
|
cmLineInfo OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBObjects 3 }
|
|
cmNotificationConfig OBJECT IDENTIFIER ::=
|
|
{ ciscoModemMgmtMIBObjects 4 }
|
|
|
|
--
|
|
-- System Wide Modem Info Table
|
|
--
|
|
|
|
cmSystemInstalledModem OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "modems"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual number of modems that are currently installed
|
|
within this system."
|
|
::= { cmSystemInfo 1 }
|
|
|
|
cmSystemConfiguredGroup OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual number of modem groups that are currently
|
|
configured within this system. Maximum value for this
|
|
object is cmSystemInstalledModem."
|
|
::= { cmSystemInfo 2 }
|
|
|
|
cmSystemWatchdogTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A passive software watchdog timer value will be used to
|
|
recover a modem which enters into an unexpected state and
|
|
hangs. When this watch dog timer times out, the modem
|
|
associated Call Processing state will be set back to IDLE,
|
|
all related TDM paths will be restored to default
|
|
configurations, and all of call processing related actions
|
|
will stop for the modem."
|
|
DEFVAL { 6 }
|
|
::= { cmSystemInfo 3 }
|
|
|
|
cmSystemStatusPollTime OBJECT-TYPE
|
|
SYNTAX Integer32 (2..120)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ideal time interval between modem status polling via the
|
|
out of band management port."
|
|
DEFVAL { 12 }
|
|
::= { cmSystemInfo 4 }
|
|
|
|
cmSystemMaxRetries OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reply event is expected to be received for every message
|
|
sent to the modem through the out of band management port.
|
|
If an expected reply event is not received, the message will
|
|
be sent to the modem again. This object specifies the maximum
|
|
number of retries that should be executed."
|
|
DEFVAL { 3 }
|
|
::= { cmSystemInfo 5 }
|
|
|
|
cmSystemModemsInUse OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of modems in the system that are in the
|
|
following states: connected, offHook, loopback,
|
|
or downloadFirmware."
|
|
::= { cmSystemInfo 6 }
|
|
|
|
cmSystemModemsAvailable OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of modems in the system that are onHook.
|
|
That is, they are ready to accept a call."
|
|
::= { cmSystemInfo 7 }
|
|
|
|
cmSystemModemsUnavailable OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of modems in the system that cannot
|
|
accept calls.
|
|
They are in a state other than onHook."
|
|
::= { cmSystemInfo 8 }
|
|
|
|
cmSystemModemsOffline OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of modems in the system, which have
|
|
been held administratively offline"
|
|
::= { cmSystemInfo 9 }
|
|
|
|
cmSystemModemsDead OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of modems in the system with the state
|
|
bad or downloadFirmwareFailed."
|
|
::= { cmSystemInfo 10 }
|
|
|
|
--
|
|
-- Modem Group General Info Table
|
|
--
|
|
|
|
cmGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of descriptive and status information about the groups
|
|
of modems."
|
|
::= { cmGroupInfo 1 }
|
|
|
|
cmGroupEntry OBJECT-TYPE
|
|
SYNTAX CmGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about a single
|
|
group of modems."
|
|
INDEX { cmGroupIndex }
|
|
::= { cmGroupTable 1 }
|
|
|
|
CmGroupEntry ::=
|
|
SEQUENCE {
|
|
cmGroupIndex Unsigned32,
|
|
cmGroupTotalDevices Integer32
|
|
}
|
|
|
|
cmGroupIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the group containing the modems for
|
|
which this entry contains information."
|
|
::= { cmGroupEntry 1 }
|
|
|
|
cmGroupTotalDevices OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of modem devices which are configured in
|
|
the group."
|
|
::= { cmGroupEntry 2 }
|
|
|
|
--
|
|
-- Table for Modem Group Members
|
|
--
|
|
|
|
cmGroupMemberTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmGroupMemberEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the modem members in modem groups."
|
|
::= { cmGroupInfo 2 }
|
|
|
|
cmGroupMemberEntry OBJECT-TYPE
|
|
SYNTAX CmGroupMemberEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about modem
|
|
members in a group. The modem groups are currently created
|
|
when an associated Async interface groups are configured
|
|
via CLI command 'interface group-async' and not via SNMP."
|
|
INDEX {
|
|
cmGroupIndex,
|
|
cmSlotIndex,
|
|
cmPortIndex
|
|
}
|
|
::= { cmGroupMemberTable 1 }
|
|
|
|
CmGroupMemberEntry ::=
|
|
SEQUENCE {
|
|
cmSlotIndex Unsigned32,
|
|
cmPortIndex Unsigned32
|
|
}
|
|
|
|
cmSlotIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modem feature card slot number in the group."
|
|
::= { cmGroupMemberEntry 1 }
|
|
|
|
cmPortIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modem port number of a modem feature card in the group."
|
|
::= { cmGroupMemberEntry 2 }
|
|
|
|
--
|
|
-- Modem Line Status Info Table
|
|
--
|
|
|
|
cmLineStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmLineStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that describe the status of the modem."
|
|
::= { cmLineInfo 1 }
|
|
|
|
cmLineStatusEntry OBJECT-TYPE
|
|
SYNTAX CmLineStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing status information about a
|
|
single modem."
|
|
INDEX { cmSlotIndex, cmPortIndex }
|
|
::= { cmLineStatusTable 1 }
|
|
|
|
CmLineStatusEntry ::=
|
|
SEQUENCE {
|
|
cmInterface InterfaceIndex,
|
|
cmGroup Integer32,
|
|
cmManufacturerID DisplayString,
|
|
cmProductDetails DisplayString,
|
|
cmManageable TruthValue,
|
|
cmState INTEGER,
|
|
cmCallDirection INTEGER,
|
|
cmDisconnectReason INTEGER,
|
|
cmCallDuration TimeTicks,
|
|
cmCallPhoneNumber DisplayString,
|
|
cmCallerID DisplayString,
|
|
cmModulationSchemeUsed INTEGER,
|
|
cmProtocolUsed INTEGER,
|
|
cmTXRate Gauge32,
|
|
cmRXRate Gauge32,
|
|
cmTXAnalogSignalLevel Integer32,
|
|
cmRXAnalogSignalLevel Integer32
|
|
}
|
|
|
|
cmInterface OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface that this modem is connected."
|
|
::= { cmLineStatusEntry 1 }
|
|
|
|
cmGroup OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modem group number that the modem may be in."
|
|
::= { cmLineStatusEntry 2 }
|
|
|
|
cmManufacturerID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description to identify the modem, including the
|
|
manufacturer's name and type of modem."
|
|
::= { cmLineStatusEntry 3 }
|
|
|
|
cmProductDetails OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description of the modem, including hardware revision
|
|
number, firmware revision number, feature set and optionally,
|
|
its serial number."
|
|
::= { cmLineStatusEntry 4 }
|
|
|
|
cmManageable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Manageable modem allows to be accessed through the out of
|
|
band management port in which the modem statistic data can be
|
|
retrieved, and the Direct Connect session can be used to
|
|
provide the test and debugging ability. This object specifies
|
|
whether this modem is a Manageable modem."
|
|
::= { cmLineStatusEntry 5 }
|
|
|
|
cmState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
onHook(2),
|
|
offHook(3),
|
|
connected(4),
|
|
busiedOut(5),
|
|
disabled(6),
|
|
bad(7),
|
|
loopback(8),
|
|
downloadFirmware(9),
|
|
downloadFirmwareFailed(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current state of modem. The meaning of each
|
|
state code is explained below:
|
|
|
|
unknown: the current state of the modem is unknown.
|
|
|
|
onHook: the condition similar to hanging up a telephone
|
|
receiver. The call cannot enter a connected state when
|
|
the modem is onHook.
|
|
|
|
offHook: The condition similar to picking up a telephone
|
|
receiver to dial or answer a call.
|
|
|
|
connected: The modem is in a state when it can transmit or
|
|
receive data over the communications line.
|
|
|
|
busiedOut: The modem is busied out (i.e. taken out of
|
|
service) and cannot make outgoing calls or receive incoming
|
|
calls.
|
|
|
|
disabled: The modem is in a reset state and non-functional.
|
|
This state can be set and clear via cmHoldReset.
|
|
|
|
bad: The modem is suspected or proven to be bad. The
|
|
operator can take the modem out of service and mark
|
|
the modem as 'bad' via cmBad.
|
|
|
|
loopback: The modem is in a state where it is currently
|
|
running back-to-back loopback testing.
|
|
|
|
downloadFirmware: The modem is in a state where it is
|
|
currently downloading the firmware.
|
|
|
|
downloadFirmwareFailed: The modem is not operational because
|
|
the downloading of firmware to it has failed."
|
|
::= { cmLineStatusEntry 6 }
|
|
|
|
cmCallDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incoming(1),
|
|
outgoing(2),
|
|
none(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modem can be used either as an incoming call or
|
|
outgoing call. This object specifies the direction of
|
|
the current or previous call."
|
|
::= { cmLineStatusEntry 7 }
|
|
|
|
cmDisconnectReason OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
lostCarrier(2),
|
|
noCarrier(3),
|
|
noDialTone(4),
|
|
busy(5),
|
|
modemWatchdogTimeout(6),
|
|
dtrDrop(7),
|
|
userHangup(8),
|
|
compressionProblem(9),
|
|
retrainFailure(10),
|
|
remoteLinkDisconnect(11),
|
|
abort(12),
|
|
inactivityTimeout(13),
|
|
dialStringError(14),
|
|
linkFailure(15),
|
|
modulationError(16),
|
|
dialTimeout(17),
|
|
remoteHangup(18),
|
|
mnp10ProtocolError(19),
|
|
lapmProtocolError(20),
|
|
faxClass2Error(21),
|
|
trainupFailure(22),
|
|
fallbackTerminate(23),
|
|
excessiveEC(24),
|
|
hostDrop(25),
|
|
terminate(26),
|
|
autoLogonError(27),
|
|
ccpNotSeen(28),
|
|
callbackFailed(29),
|
|
blacklist(30),
|
|
lapmTimeout(31),
|
|
reliableLinkTxTimeout(32),
|
|
dspAccessFailure(33),
|
|
cdOffTimeout(34),
|
|
codewordSizeMismatch(35),
|
|
dspDownloadFailure(36),
|
|
modemDrNone(37),
|
|
modemDrSoftwareReset(38),
|
|
modemDrEcTerminated(39),
|
|
modemDrBadMnp5Rxdata(40),
|
|
modemDrBadV42bisRxdata(41),
|
|
modemDrBadCopState(42),
|
|
modemDrAth(43),
|
|
modemDrAborted(44),
|
|
modemDrConnectTimeout(45),
|
|
modemDrResetDsp(46),
|
|
modemDrNoCarrier(47),
|
|
modemDrNoAbtDetected(48),
|
|
modemDrTrainupFailure(49),
|
|
modemDrRetrainLimit(50),
|
|
modemDrAbtEndFailure(51),
|
|
modemDrNoLr(52),
|
|
modemDrLrParam1(53),
|
|
modemDrLrIncompat(54),
|
|
modemDrRetransmitLimit(55),
|
|
modemDrInactivity(56),
|
|
modemDrProtocolError(57),
|
|
modemDrFallbackTerminate(58),
|
|
modemDrNoXid(59),
|
|
modemDrXidIncompat(60),
|
|
modemDrDisc(61),
|
|
modemDrDm(62),
|
|
modemDrBadNr(63),
|
|
modemDrSabmeOnline(64),
|
|
modemDrXidOnline(65),
|
|
modemDrLrOnline(66),
|
|
modemDrBadCmnd(67),
|
|
modemDrFrmrBadCmnd(68),
|
|
modemDrFrmrData(69),
|
|
modemDrFrmrLength(70),
|
|
modemDrFrmrBadNr(71),
|
|
modemDrLdNoLr(72),
|
|
modemDrLdLrParam1(73),
|
|
modemDrLdLrIncompat(74),
|
|
modemDrLdRetransLimit(75),
|
|
modemDrLdInactivity(76),
|
|
modemDrLdProtocol(77),
|
|
modemDrLdUser(78),
|
|
modemDrHostNonspecific(79),
|
|
modemDrHostBusy(80),
|
|
modemDrHostNoAnswer(81),
|
|
modemDrHostDtr(82),
|
|
modemDrHostAth(83),
|
|
modemDrHostNoDialtone(84),
|
|
modemDrHostNoCarrier(85),
|
|
modemDrHostAck(86),
|
|
modemDrMohClrd(87),
|
|
modemDrMohTimeout(88),
|
|
modemDrCotAck(89),
|
|
modemDrCotNak1(90),
|
|
modemDrCotNak2(91),
|
|
modemDrCotOff(92),
|
|
modemDrCotTimeout(93),
|
|
modemDrDcIllegalCodewordStepup(94),
|
|
modemDrDcIllegalTokenEmptyNode(95),
|
|
modemDrDcIllegalTokenTooLarge(96),
|
|
modemDrDcReservedCommand(97),
|
|
modemDrDcIllegalCharacterSizeStepup(98),
|
|
modemDrDcRxDictionaryFull(99),
|
|
modemDrDcRxHistoryFull(100),
|
|
modemDrDcRxStringSizeExceeded(101),
|
|
modemDrDcNegotiationError(102),
|
|
modemDrDcCompressionError(103)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the reason that the last connection or call attempt
|
|
disconnected. The meaning of each reason code is explained
|
|
below:
|
|
|
|
unknown: the failure reason is unknown or there has been
|
|
no previous call.
|
|
|
|
lostCarrier: the call was disconnected because the loss
|
|
of carrier.
|
|
|
|
noCarrier: the dial out attempt has failed because the
|
|
modem detects no carrier.
|
|
|
|
noDialTone: the dial out attempt has failed because the
|
|
modem failed to detect a dial tone.
|
|
|
|
busy: the call attempt failed because the modem detected
|
|
a busy signal.
|
|
|
|
modemWatchdogTimeout: the modem internal watchdog timer
|
|
has expired.
|
|
|
|
dtrDrop: DTR has been turned off while the modem is to
|
|
disconnect on DTR drop.
|
|
|
|
userHangup: normal disconnect where the user hangs up call.
|
|
|
|
compressionProblem: the call is disconnected due to a
|
|
problem detected during compression in the modem.
|
|
|
|
retrainFailure: the modem did not successfully train and
|
|
reach data mode on the previous connections.
|
|
|
|
remoteLinkDisconnect: the remote link disconnected the
|
|
connection.
|
|
|
|
abort: the call was aborted.
|
|
|
|
inactivityTimeout: the modem automatically hangs up because
|
|
data is not sent or received within the inactivity time out.
|
|
|
|
dialStringError: the dialed phone number is invalid.
|
|
|
|
linkFailure: the modem detects a link failure.
|
|
|
|
modulationError: the modem detects a modulation error.
|
|
|
|
dialTimeout: the modem times out while attempting to dial.
|
|
|
|
remoteHangup: the remote side hangs up the connection.
|
|
|
|
mnp10ProtocolError: MNP10 Protocol Error.
|
|
|
|
lapmProtocolError: LAPM Protocol Error.
|
|
|
|
faxClass2Error: Fax Class 2 Error.
|
|
|
|
trainupFailure: failure to trainup with a remote peer.
|
|
|
|
fallbackTerminate: User has EC fallback set to disconnect.
|
|
|
|
excessiveEC: Link loss due to excessive EC retransmissions.
|
|
EC packet transmit limit exceeded.
|
|
|
|
hostDrop: Host initiated link drop.
|
|
|
|
terminate: Lost Carrier Microcom HDMS product relating to
|
|
password security issues.
|
|
|
|
autoLogonError: An autologon sequence did not complete
|
|
successfully.
|
|
|
|
ccpNotSeen: The Credit Card Prompt was not detected.
|
|
|
|
callbackFailed: Applies to leased line connection. If after
|
|
a switched line dialback due to a leased line connection
|
|
failure, the switched line connection also fails and a
|
|
connection can still not be made on the leased line, a
|
|
disconnect occurs with this reason set.
|
|
|
|
blacklist: In coutries that support blacklisting, an attempt
|
|
was made to go off hook with a null dial string (ATD).
|
|
|
|
lapmTimeout: Timed out waiting for a reply from remote.
|
|
|
|
reliableLinkTxTimeout: Have not received the
|
|
link acknowledgement in the first 30 seconds of the
|
|
connection.
|
|
|
|
dspAccessFailure: Timed out trying to access the
|
|
DSP chip.
|
|
|
|
cdOffTimeout: Timed out waiting for carrier to return
|
|
after a retrain or rate renegotiation.
|
|
|
|
codewordSizeMismatch: The codeword size are mismatched.
|
|
|
|
dspDownloadFailure: Error during the DSP code download.
|
|
The time taken to recover and repeat the download
|
|
would take too long to complete the handshake."
|
|
|
|
::= { cmLineStatusEntry 8 }
|
|
|
|
cmCallDuration OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the call duration of the current
|
|
or previous call."
|
|
::= { cmLineStatusEntry 9 }
|
|
|
|
cmCallPhoneNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The dialed outgoing telephone number of the current or
|
|
previous call."
|
|
::= { cmLineStatusEntry 10 }
|
|
|
|
cmCallerID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The incoming caller identification of the current or
|
|
previous call if this entry is not in the connected state."
|
|
::= { cmLineStatusEntry 11 }
|
|
|
|
cmModulationSchemeUsed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
bell103a(2),
|
|
bell212a(3),
|
|
v21(4),
|
|
v22(5),
|
|
v22bis(6),
|
|
v32(7),
|
|
v32bis(8),
|
|
vfc(9),
|
|
v34(10),
|
|
v17(11),
|
|
v29(12),
|
|
v33(13),
|
|
k56flex(14),
|
|
v23(15),
|
|
v32terbo(16),
|
|
v34plus(17),
|
|
v90(18),
|
|
v27ter(19),
|
|
v110(20),
|
|
piafs(21)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modem modulation scheme used in the current or previous
|
|
call. This object is valid only for modems which have
|
|
cmManageable to be true."
|
|
::= { cmLineStatusEntry 12 }
|
|
|
|
cmProtocolUsed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
direct(2),
|
|
reliableMNP(3),
|
|
reliableLAPM(4),
|
|
syncMode(5),
|
|
asyncMode(6),
|
|
ara10(7),
|
|
ara20(8),
|
|
unknown(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modem protocol used in the current or previous call.
|
|
This object is valid only for modems which have cmManageable
|
|
to be true."
|
|
::= { cmLineStatusEntry 13 }
|
|
|
|
cmTXRate OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "bits/second"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The speed of modem transmit rate of the current or previous
|
|
call in bits per second. This object is valid only for modems
|
|
which have cmManageable to be true."
|
|
::= { cmLineStatusEntry 14 }
|
|
|
|
cmRXRate OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "bits/second"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The speed of modem receive rate of the current or previous
|
|
call in bits per second. This object is valid only for modems
|
|
which have cmManageable to be true."
|
|
::= { cmLineStatusEntry 15 }
|
|
|
|
cmTXAnalogSignalLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-43..-9 | 0)
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modem transmit analog signal level in the current or
|
|
previous call. The unit used is in dBm. This object
|
|
is valid for modems that have cmManageable set to true(1)
|
|
otherwise 0 will be returned."
|
|
::= { cmLineStatusEntry 16 }
|
|
|
|
cmRXAnalogSignalLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..-1 | 0)
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modem transmit analog signal level in the current or
|
|
previous call. The unit used is in dBm. This object
|
|
is valid for modems that have cmManageable set to true(1)
|
|
otherwise 0 will be returned."
|
|
::= { cmLineStatusEntry 17 }
|
|
|
|
--
|
|
-- Modem Line Configuration Table
|
|
--
|
|
|
|
cmLineConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmLineConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that describe some of the configuration
|
|
info of the modem."
|
|
::= { cmLineInfo 2 }
|
|
|
|
cmLineConfigEntry OBJECT-TYPE
|
|
SYNTAX CmLineConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing configuration information
|
|
about a single modem."
|
|
AUGMENTS { cmLineStatusEntry }
|
|
::= { cmLineConfigTable 1 }
|
|
|
|
CmLineConfigEntry ::=
|
|
SEQUENCE {
|
|
cmATModePermit TruthValue,
|
|
cmStatusPolling TruthValue,
|
|
cmBusyOutRequest TruthValue,
|
|
cmShutdown TruthValue,
|
|
cmHoldReset TruthValue,
|
|
cmBad TruthValue
|
|
}
|
|
|
|
cmATModePermit OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Direct Connect session is used for test and debugging purpose
|
|
by using the modem AT commands through the out of band
|
|
management port when cmManageable is true.
|
|
|
|
This object specifies whether the Direct Connect session is
|
|
permitted to be used at this modem.
|
|
|
|
If cmManageable is true(1), Direct Connect session via the out
|
|
of band port is allowed and false(2) indicates that it isn't
|
|
allowed for the modem."
|
|
DEFVAL { true }
|
|
::= { cmLineConfigEntry 1 }
|
|
|
|
cmStatusPolling OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modem status and events can be polled through the out of band
|
|
management port when the cmManageable is true.
|
|
|
|
This object specifies whether this status polling feature is
|
|
enabled at this modem.
|
|
|
|
If cmManageable is true(1), status polling will occur for the
|
|
modem and false(2) indicates that no status polling will occur."
|
|
DEFVAL { true }
|
|
::= { cmLineConfigEntry 2 }
|
|
|
|
cmBusyOutRequest OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to put modem out of service, i.e. modem
|
|
cannot make calls or answer calls. If the modem to
|
|
be busyout is handling a call, the busyout action will
|
|
be taken after the current call is disconnected. After
|
|
modem is busyout, the following commands can be applied
|
|
to those modems - reset, bad modem, download modem firmware,
|
|
etc. This is called nice or graceful busyout.
|
|
|
|
The value of true(1) indicates the busyOut request has been
|
|
issued to the modem, but the busyout could be pending. The
|
|
management entity needs to query the cmState to see
|
|
if the modem is successfully busied out. The value of false(2)
|
|
indicates the modem is not given the busyOut command."
|
|
DEFVAL { false }
|
|
::= { cmLineConfigEntry 3 }
|
|
|
|
cmShutdown OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to put modem out of service, i.e. modem
|
|
cannot make calls or answer calls. This is a hard busyout
|
|
command to bring the modem out of service immediately without
|
|
waiting for the call to be ended normally. After modem is
|
|
shutdown, the following commands can be applied to those
|
|
modems - reset, bad modem, download modem firmware, etc.
|
|
|
|
The value of true(1) indicates the hard busyout has been
|
|
issued to the modem. The value of false(2) indicates the
|
|
modem has not been hard busyout."
|
|
DEFVAL { false }
|
|
::= { cmLineConfigEntry 4 }
|
|
|
|
cmHoldReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A command hold-reset will put the state of modem into reset mode
|
|
until an inverse command to bring modem out of RESET mode.
|
|
During the period of reset mode, this modem can not be used
|
|
and is non-functional.
|
|
|
|
This object is only valid when cmState is onHook, busiedOut, or
|
|
disabled. The value of true(1) attempts to put the modem in
|
|
reset mode, and the value of false(2) takes the modem out of
|
|
reset.
|
|
|
|
This object is not applicable for Mica modems."
|
|
DEFVAL { false }
|
|
::= { cmLineConfigEntry 5 }
|
|
|
|
cmBad OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object can hold modem out of service and marks the modem
|
|
as suspected or proven to be bad. During the router start-up
|
|
initialization sequence, modem back-to-back tests will test
|
|
modems and mark those modems failing tests as bad modems. The
|
|
management entity also can use this command to lock out the
|
|
suspicious modem or unlock the modem to do further debugging
|
|
or test. This command will be used accompanied with cmholdReset
|
|
command to put modem out of service. This command doesn't do
|
|
the reset. For a normally good modem, it can start handling
|
|
calls after it exits from modem reset mode. For a bad modem, it
|
|
cannot start handling calls after it exits from modem reset
|
|
mode. The manager needs to take modem out of bad modem mode
|
|
in order to handle calls.
|
|
|
|
This object is only valid when cmState is onHook or
|
|
busiedOut. The value of true(1) indicates the modem is
|
|
suspected to be bad and its state is set to bad. The
|
|
value of false(2) indicates the modem has not been suspected
|
|
to be bad or has been re-marked as good."
|
|
DEFVAL { false }
|
|
::= { cmLineConfigEntry 6 }
|
|
|
|
--
|
|
-- Modem Line Statistics Table
|
|
--
|
|
|
|
cmLineStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmLineStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that describe the status of the modem."
|
|
::= { cmLineInfo 3 }
|
|
|
|
cmLineStatisticsEntry OBJECT-TYPE
|
|
SYNTAX CmLineStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing status information about a
|
|
single modem."
|
|
AUGMENTS { cmLineStatusEntry }
|
|
::= { cmLineStatisticsTable 1 }
|
|
|
|
CmLineStatisticsEntry ::=
|
|
SEQUENCE {
|
|
cmRingNoAnswers Counter32,
|
|
cmIncomingConnectionFailures Counter32,
|
|
cmIncomingConnectionCompletions Counter32,
|
|
cmOutgoingConnectionFailures Counter32,
|
|
cmOutgoingConnectionCompletions Counter32,
|
|
cmFailedDialAttempts Counter32,
|
|
cmNoDialTones Counter32,
|
|
cmDialTimeouts Counter32,
|
|
cmWatchdogTimeouts Counter32,
|
|
cm2400OrLessConnections Counter32, -- deprecated
|
|
cm2400To14400Connections Counter32, -- deprecated
|
|
cmGreaterThan14400Connections Counter32, -- deprecated
|
|
cmNoCarriers Counter32,
|
|
cmLinkFailures Counter32,
|
|
cmProtocolErrors Counter32,
|
|
cmPollingTimeouts Counter32,
|
|
cmTotalCallDuration Counter32
|
|
}
|
|
|
|
cmRingNoAnswers OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter to count the calls that ringing was detected but
|
|
the call was not answered at this modem."
|
|
::= { cmLineStatisticsEntry 1 }
|
|
|
|
cmIncomingConnectionFailures OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of incoming
|
|
connection requests that this modem answered in
|
|
which it could not train with the other DCE.
|
|
This object is valid only for modems which have
|
|
cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 2 }
|
|
|
|
cmIncomingConnectionCompletions OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of incoming
|
|
connection requests that this modem answered and
|
|
successfully trained with the other DCE. This
|
|
object is valid only for modems which have
|
|
cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 3 }
|
|
|
|
cmOutgoingConnectionFailures OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of outgoing
|
|
calls from this modem which successfully went off
|
|
hook and dialed, in which it could not train with
|
|
the other DCE. This object is valid only for
|
|
modems which have cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 4 }
|
|
|
|
cmOutgoingConnectionCompletions OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of outgoing
|
|
calls from this modem which resulted in successfully
|
|
training with the other DCE.This object is valid
|
|
only for modems which have cmManageable to
|
|
be true."
|
|
::= { cmLineStatisticsEntry 5 }
|
|
|
|
cmFailedDialAttempts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of call
|
|
attempts that failed because the modem didn't go
|
|
off hook, or there was no dial tone."
|
|
::= { cmLineStatisticsEntry 6 }
|
|
|
|
cmNoDialTones OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of times the
|
|
dial tone expected but not received. This object
|
|
is valid only for modems which have cmManageable
|
|
to be true."
|
|
::= { cmLineStatisticsEntry 7 }
|
|
|
|
cmDialTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of times the
|
|
dial time-out occurred. This object is valid only
|
|
for modems which have cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 8 }
|
|
|
|
cmWatchdogTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the Call Processing watchdog
|
|
timer has expired."
|
|
::= { cmLineStatisticsEntry 9 }
|
|
|
|
cm2400OrLessConnections OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The number of connections initially established at
|
|
a modulation speed of 2400 bits per second or less.
|
|
This object is valid only for modems which have
|
|
cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 10 }
|
|
|
|
cm2400To14400Connections OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The number of connections initially established at a modulation
|
|
speed of greater than 2400 bits per second and less than 14400
|
|
bits per second. This object is valid only for modems which
|
|
have cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 11 }
|
|
|
|
cmGreaterThan14400Connections OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The number of connections initially established at a modulation
|
|
speed of greater than 14400 bits per second. This object is
|
|
valid only for modems which have cmManageable to be true."
|
|
|
|
::= { cmLineStatisticsEntry 12 }
|
|
|
|
cmNoCarriers OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of times that the
|
|
disconnect reason is no carrier. This object is valid only for
|
|
modems which have cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 13 }
|
|
|
|
cmLinkFailures OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of times that the
|
|
disconnect reason is link failure. This object is valid only
|
|
for modems which have cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 14 }
|
|
|
|
cmProtocolErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "errors"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of times that the out of
|
|
band protocol error occurred. This object is valid only for
|
|
modems which have cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 15 }
|
|
|
|
cmPollingTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "errors"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates the number of times that the out of
|
|
band protocol time-out error occurred. This object is valid
|
|
only for modems which have cmManageable to be true."
|
|
::= { cmLineStatisticsEntry 16 }
|
|
|
|
cmTotalCallDuration OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter that indicates total call duration on the modem. This
|
|
includes the duration of all previous calls."
|
|
::= { cmLineStatisticsEntry 17 }
|
|
--
|
|
-- Modem Line Speed Statistics Table
|
|
--
|
|
|
|
|
|
cmLineSpeedStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmLineSpeedStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that describe the intial modem
|
|
line speeds and connections"
|
|
::= { cmLineInfo 4 }
|
|
|
|
cmLineSpeedStatisticsEntry OBJECT-TYPE
|
|
SYNTAX CmLineSpeedStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing initial speed and
|
|
connection information about a single modem."
|
|
INDEX { cmSlotIndex, cmPortIndex, cmInitialLineSpeed }
|
|
::= { cmLineSpeedStatisticsTable 1}
|
|
|
|
CmLineSpeedStatisticsEntry ::=
|
|
SEQUENCE {
|
|
cmInitialLineSpeed Unsigned32,
|
|
cmInitialLineConnections Counter32, -- deprecated
|
|
cmInitialTxLineConnections Counter32,
|
|
cmInitialRxLineConnections Counter32
|
|
}
|
|
|
|
cmInitialLineSpeed OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A discrete initial speed at which the given line
|
|
may operate"
|
|
::= { cmLineSpeedStatisticsEntry 1 }
|
|
|
|
cmInitialLineConnections OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated -- superceded by cmInitialTxLineConnections
|
|
DESCRIPTION
|
|
"The number of connections initially established at a
|
|
given modulation speed. An instance of this object
|
|
will be only present for those speeds where one or more
|
|
connections have occurred"
|
|
::= { cmLineSpeedStatisticsEntry 2 }
|
|
|
|
cmInitialTxLineConnections OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Transmit connections initially established at a
|
|
given modulation speed. An instance of this object
|
|
will be only present for those speeds where one or more
|
|
connections have occurred"
|
|
::= { cmLineSpeedStatisticsEntry 3 }
|
|
|
|
cmInitialRxLineConnections OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "calls"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Receive connections initially established at a
|
|
given modulation speed. An instance of this object
|
|
will be only present for those speeds where one or more
|
|
connections have occurred"
|
|
::= { cmLineSpeedStatisticsEntry 4 }
|
|
|
|
|
|
|
|
--
|
|
-- Notification Configuration
|
|
--
|
|
cmStateNotifyEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable controls generation of the
|
|
cmStateNotification.
|
|
|
|
When this variable is 'true(1)', generation of
|
|
cmStateNotification is enabled. When this variable
|
|
is 'false(2)', generation of cmStateNotification
|
|
is disabled.
|
|
|
|
The default value is 'false(2)'.
|
|
"
|
|
::= { cmNotificationConfig 1 }
|
|
|
|
|
|
|
|
-- ******************************************************************
|
|
-- Notifications
|
|
-- ******************************************************************
|
|
cmMIBNotificationPrefix OBJECT IDENTIFIER ::= { ciscoModemMgmtMIB 2 }
|
|
|
|
cmMIBNotifications OBJECT IDENTIFIER ::=
|
|
{ cmMIBNotificationPrefix 0 }
|
|
|
|
|
|
cmStateNotification NOTIFICATION-TYPE
|
|
OBJECTS { cmState }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A modem port state change notification is generated whenever
|
|
the port transitions to a state where it is offline due to
|
|
a failure or administrative action.
|
|
|
|
The values of cmState which will trigger this notification are:
|
|
busiedOut(5) - Administratively out of service
|
|
disabled(6) - Administratively out of service
|
|
bad(7) - Internally detected failure or
|
|
administrative action
|
|
loopback(8) - Testing
|
|
downloadFirmware(9) - Administrative action
|
|
downloadFirmwareFailed(10) - Internally detected failure
|
|
"
|
|
::= { cmMIBNotifications 1 }
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
|
|
ciscoModemMgmtMIBConformance OBJECT IDENTIFIER ::= { ciscoModemMgmtMIB 3 }
|
|
ciscoModemMgmtMIBCompliances OBJECT IDENTIFIER ::=
|
|
{ ciscoModemMgmtMIBConformance 1 }
|
|
ciscoModemMgmtMIBGroups OBJECT IDENTIFIER ::=
|
|
{ ciscoModemMgmtMIBConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
ciscoModemMgmtMIBCompliance MODULE-COMPLIANCE
|
|
STATUS obsolete -- superseded by ciscoModemMgmtMIBComplianceRev1
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the cisco Modem Management MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmSystemInfoGroup,
|
|
cmLineInfoGroup,
|
|
cmGroupInfoGroup
|
|
}
|
|
GROUP cmManagedLineInfoGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for all managed modems."
|
|
::= { ciscoModemMgmtMIBCompliances 1 }
|
|
|
|
ciscoModemMgmtMIBComplianceRev1 MODULE-COMPLIANCE
|
|
STATUS obsolete -- superseded by ciscoModemMgmtMIBComplianceRev2
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the cisco Modem Management MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmSystemInfoGroup,
|
|
cmLineInfoGroup,
|
|
cmGroupInfoGroup
|
|
}
|
|
GROUP cmManagedLineInfoGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for all managed modems."
|
|
GROUP cmLineSpeedInfoGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for all managed modems."
|
|
::= { ciscoModemMgmtMIBCompliances 2 }
|
|
|
|
ciscoModemMgmtMIBComplianceRev2 MODULE-COMPLIANCE
|
|
STATUS obsolete -- superceded by ciscoModemMgmtMIBComplianceRev3
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the cisco Modem Management MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmSystemInfoGroupRev1,
|
|
cmLineInfoGroup,
|
|
cmGroupInfoGroup
|
|
}
|
|
GROUP cmManagedLineInfoGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for all managed modems."
|
|
GROUP cmLineSpeedInfoGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for all managed modems."
|
|
|
|
OBJECT cmSystemWatchdogTime
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
::= { ciscoModemMgmtMIBCompliances 3 }
|
|
|
|
ciscoModemMgmtMIBComplianceRev3 MODULE-COMPLIANCE
|
|
STATUS obsolete -- superceded by ciscoModemMgmtMIBComplianceRev4
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the cisco Modem Management MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmSystemInfoGroupRev1,
|
|
cmLineInfoGroup,
|
|
cmGroupInfoGroup
|
|
}
|
|
GROUP cmManagedLineInfoGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for all managed modems."
|
|
GROUP cmLineSpeedInfoGroupRev1
|
|
DESCRIPTION
|
|
"This group is mandatory for all managed modems."
|
|
|
|
OBJECT cmSystemWatchdogTime
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
::= { ciscoModemMgmtMIBCompliances 4 }
|
|
|
|
ciscoModemMgmtMIBComplianceRev4 MODULE-COMPLIANCE
|
|
STATUS obsolete -- superceded by ciscoModemMgmtMIBComplianceRev5
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the cisco Modem Management MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmGroupInfoGroup
|
|
}
|
|
GROUP cmLineSpeedInfoGroupRev1
|
|
DESCRIPTION
|
|
"This group is mandatory only for managed modems."
|
|
|
|
GROUP cmManagedLineInfoGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for managed modems.
|
|
The following modifications may apply."
|
|
|
|
OBJECT cmTXAnalogSignalLevel
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Not supported for MICA or nextport modems."
|
|
|
|
OBJECT cmPollingTimeouts
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
GROUP cmLineInfoGroup
|
|
DESCRIPTION
|
|
"With the following modifications, this group
|
|
is mandatory for all modems."
|
|
|
|
OBJECT cmATModePermit
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"AT Mode not required."
|
|
|
|
OBJECT cmHoldReset
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"HoldReset not required."
|
|
|
|
OBJECT cmStatusPolling
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
GROUP cmSystemInfoGroupRev1
|
|
DESCRIPTION
|
|
"With the following modifications, this group
|
|
is mandatory for all modems."
|
|
|
|
OBJECT cmSystemWatchdogTime
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access not supported."
|
|
|
|
OBJECT cmSystemStatusPollTime
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
OBJECT cmSystemMaxRetries
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
::= { ciscoModemMgmtMIBCompliances 5 }
|
|
|
|
ciscoModemMgmtMIBComplianceRev5 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the cisco Modem Management MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmGroupInfoGroup
|
|
}
|
|
GROUP cmLineSpeedInfoGroupRev1
|
|
DESCRIPTION
|
|
"This group is mandatory only for managed modems."
|
|
|
|
GROUP cmManagedLineInfoGroupRev1
|
|
DESCRIPTION
|
|
"This group is mandatory only for managed modems.
|
|
The following modifications may apply."
|
|
|
|
OBJECT cmTXAnalogSignalLevel
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Not supported for MICA or nextport modems."
|
|
|
|
OBJECT cmPollingTimeouts
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
GROUP cmLineInfoGroup
|
|
DESCRIPTION
|
|
"With the following modifications, this group
|
|
is mandatory for all modems."
|
|
|
|
OBJECT cmATModePermit
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"AT Mode not required."
|
|
|
|
OBJECT cmHoldReset
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"HoldReset not required."
|
|
|
|
OBJECT cmStatusPolling
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
GROUP cmSystemInfoGroupRev1
|
|
DESCRIPTION
|
|
"With the following modifications, this group
|
|
is mandatory for all modems."
|
|
|
|
OBJECT cmSystemWatchdogTime
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access not supported."
|
|
|
|
OBJECT cmSystemStatusPollTime
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
OBJECT cmSystemMaxRetries
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
GROUP cmNotificationConfigGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for systems supporting
|
|
generation of modem notifications."
|
|
|
|
|
|
GROUP cmNotificationGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for systems supporting
|
|
generation of modem notifications."
|
|
|
|
::= { ciscoModemMgmtMIBCompliances 6 }
|
|
|
|
ciscoModemMgmtMIBComplianceRev6 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the cisco Modem Management MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmGroupInfoGroup
|
|
}
|
|
GROUP cmLineSpeedInfoGroupRev2
|
|
DESCRIPTION
|
|
"This group is mandatory only for managed modems."
|
|
|
|
GROUP cmManagedLineInfoGroupRev2
|
|
DESCRIPTION
|
|
"This group is mandatory only for managed modems.
|
|
The following modifications may apply."
|
|
|
|
OBJECT cmTXAnalogSignalLevel
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Not supported for MICA or nextport modems."
|
|
|
|
OBJECT cmPollingTimeouts
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
GROUP cmLineInfoGroup
|
|
DESCRIPTION
|
|
"With the following modifications, this group
|
|
is mandatory for all modems."
|
|
|
|
OBJECT cmATModePermit
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"AT Mode not required."
|
|
|
|
OBJECT cmHoldReset
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"HoldReset not required."
|
|
|
|
OBJECT cmStatusPolling
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
GROUP cmSystemInfoGroupRev1
|
|
DESCRIPTION
|
|
"With the following modifications, this group
|
|
is mandatory for all modems."
|
|
|
|
OBJECT cmSystemWatchdogTime
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access not supported."
|
|
|
|
OBJECT cmSystemStatusPollTime
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
OBJECT cmSystemMaxRetries
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"Status Polling not required."
|
|
|
|
GROUP cmNotificationConfigGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for systems supporting
|
|
generation of modem notifications."
|
|
|
|
GROUP cmNotificationGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for systems supporting
|
|
generation of modem notifications."
|
|
|
|
::= { ciscoModemMgmtMIBCompliances 7 }
|
|
|
|
|
|
-- units of conformance
|
|
|
|
cmSystemInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmSystemInstalledModem,
|
|
cmSystemConfiguredGroup,
|
|
cmSystemWatchdogTime,
|
|
cmSystemStatusPollTime,
|
|
cmSystemMaxRetries
|
|
}
|
|
STATUS obsolete -- superseded by ciscoSystemInfoGroupRev1
|
|
DESCRIPTION
|
|
"A collection of objects providing system configuration and
|
|
status information."
|
|
::= { ciscoModemMgmtMIBGroups 1 }
|
|
|
|
cmGroupInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
-- modem group info
|
|
cmGroupTotalDevices,
|
|
-- modem group members info
|
|
cmPortIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing modem configuration and
|
|
statistics information for modem groups."
|
|
::= { ciscoModemMgmtMIBGroups 2 }
|
|
|
|
cmLineInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
-- status
|
|
cmInterface,
|
|
cmGroup,
|
|
cmManufacturerID,
|
|
cmProductDetails,
|
|
cmManageable,
|
|
cmState,
|
|
cmDisconnectReason,
|
|
cmCallDirection,
|
|
cmCallDuration,
|
|
cmCallPhoneNumber,
|
|
cmCallerID,
|
|
-- configurations
|
|
cmATModePermit,
|
|
cmStatusPolling,
|
|
cmBusyOutRequest,
|
|
cmShutdown,
|
|
cmHoldReset,
|
|
cmBad,
|
|
-- statistics
|
|
cmRingNoAnswers,
|
|
cmFailedDialAttempts,
|
|
cmWatchdogTimeouts
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing modem configuration and
|
|
statistics information for individual modem."
|
|
::= { ciscoModemMgmtMIBGroups 3 }
|
|
|
|
cmManagedLineInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmModulationSchemeUsed,
|
|
cmProtocolUsed,
|
|
cmTXRate,
|
|
cmRXRate,
|
|
cmTXAnalogSignalLevel,
|
|
cmRXAnalogSignalLevel,
|
|
cmIncomingConnectionFailures,
|
|
cmIncomingConnectionCompletions,
|
|
cmOutgoingConnectionFailures,
|
|
cmOutgoingConnectionCompletions,
|
|
cmNoDialTones,
|
|
cmDialTimeouts,
|
|
cm2400OrLessConnections, -- deprecated
|
|
cm2400To14400Connections, -- deprecated
|
|
cmGreaterThan14400Connections, -- deprecated
|
|
cmNoCarriers,
|
|
cmLinkFailures,
|
|
cmProtocolErrors,
|
|
cmPollingTimeouts,
|
|
cmTotalCallDuration
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects providing modem configuration and
|
|
statistics information for individual managed modems."
|
|
::= { ciscoModemMgmtMIBGroups 4 }
|
|
|
|
cmLineSpeedInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmInitialLineConnections -- deprecated
|
|
}
|
|
STATUS obsolete -- superceded by cmLineSpeedInfogroupRev1
|
|
DESCRIPTION
|
|
"A collection of objects providing modem configuration and
|
|
statistics information for individual managed modems."
|
|
::= { ciscoModemMgmtMIBGroups 5 }
|
|
|
|
cmSystemInfoGroupRev1 OBJECT-GROUP
|
|
OBJECTS {
|
|
cmSystemInstalledModem,
|
|
cmSystemConfiguredGroup,
|
|
cmSystemWatchdogTime,
|
|
cmSystemStatusPollTime,
|
|
cmSystemMaxRetries,
|
|
cmSystemModemsInUse,
|
|
cmSystemModemsAvailable,
|
|
cmSystemModemsUnavailable,
|
|
cmSystemModemsOffline,
|
|
cmSystemModemsDead
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing system configuration and
|
|
status information."
|
|
::= { ciscoModemMgmtMIBGroups 6 }
|
|
|
|
cmLineSpeedInfoGroupRev1 OBJECT-GROUP
|
|
OBJECTS {
|
|
cmInitialLineConnections, -- deprecated
|
|
cmInitialTxLineConnections,
|
|
cmInitialRxLineConnections
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects providing modem configuration and
|
|
statistics information for individual managed modems."
|
|
::= { ciscoModemMgmtMIBGroups 7 }
|
|
|
|
cmManagedLineInfoGroupRev1 OBJECT-GROUP
|
|
OBJECTS {
|
|
|
|
cmModulationSchemeUsed,
|
|
cmProtocolUsed,
|
|
cmTXRate,
|
|
cmRXRate,
|
|
cmTXAnalogSignalLevel,
|
|
cmRXAnalogSignalLevel,
|
|
cmIncomingConnectionFailures,
|
|
cmIncomingConnectionCompletions,
|
|
cmOutgoingConnectionFailures,
|
|
cmOutgoingConnectionCompletions,
|
|
cmNoDialTones,
|
|
cmDialTimeouts,
|
|
cm2400OrLessConnections, -- deprecated
|
|
cm2400To14400Connections, -- deprecated
|
|
cmGreaterThan14400Connections, -- deprecated
|
|
cmNoCarriers,
|
|
cmLinkFailures,
|
|
cmProtocolErrors,
|
|
cmPollingTimeouts,
|
|
cmTotalCallDuration
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects providing modem configuration and
|
|
statistics information for individual managed modems."
|
|
::= { ciscoModemMgmtMIBGroups 8 }
|
|
|
|
cmNotificationConfigGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmStateNotifyEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for configuring the notification behavior
|
|
of this MIB.
|
|
"
|
|
::= { ciscoModemMgmtMIBGroups 9 }
|
|
|
|
cmNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
cmStateNotification
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of notifications used for
|
|
monitoring modem status"
|
|
::= { ciscoModemMgmtMIBGroups 10 }
|
|
|
|
|
|
cmLineSpeedInfoGroupRev2 OBJECT-GROUP
|
|
OBJECTS {
|
|
cmInitialTxLineConnections,
|
|
cmInitialRxLineConnections
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing modem configuration and
|
|
statistics information for individual managed modems."
|
|
::= { ciscoModemMgmtMIBGroups 11 }
|
|
|
|
cmManagedLineInfoGroupRev2 OBJECT-GROUP
|
|
OBJECTS {
|
|
cmModulationSchemeUsed,
|
|
cmProtocolUsed,
|
|
cmTXRate,
|
|
cmRXRate,
|
|
cmTXAnalogSignalLevel,
|
|
cmRXAnalogSignalLevel,
|
|
cmIncomingConnectionFailures,
|
|
cmIncomingConnectionCompletions,
|
|
cmOutgoingConnectionFailures,
|
|
cmOutgoingConnectionCompletions,
|
|
cmNoDialTones,
|
|
cmDialTimeouts,
|
|
cmNoCarriers,
|
|
cmLinkFailures,
|
|
cmProtocolErrors,
|
|
cmPollingTimeouts,
|
|
cmTotalCallDuration
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing modem configuration and
|
|
statistics information for individual managed modems."
|
|
::= { ciscoModemMgmtMIBGroups 12 }
|
|
|
|
END
|
|
|
|
|
|
|