-- CISCO-METRO-PHY-MIB.my
--
-- Feb 2001, Sonal Maheshwari, Mickey Spiegel
-- May 2002, Sonal Maheshwari, Mickey Spiegel
-- Dec 2002, Arvind Prabhudev, Sonal Maheshwari, Mickey Spiegel
--
-- Copyright (c) 2001, 2002, 2003, 2004 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
CISCO-METRO-PHY-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32,
Counter32,
Unsigned32,
Counter64,
MODULE-IDENTITY,
OBJECT-TYPE FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
TruthValue FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
ifIndex FROM IF-MIB
ciscoExperiment FROM CISCO-SMI
;
ciscoMetroPhyMIB MODULE-IDENTITY
LAST-UPDATED "200411190000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO "Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
Tel: +1 800 553-NETS
E-mail: cs-dwdm@cisco.com"
DESCRIPTION
"This MIB module defines the managed objects for physical
layer related interface configurations and objects
for the protocol specific error counters for DWDM
optical switches.
This MIB contains three groups.
The first group, cmPhyIf group, handles the physical layer
related interface configurations. The cmPhyIfTable has objects
for configuring protocol, rate, error monitoring, loopback
mode and safety features like OFC (Open Fibre Control), laser
safety control and forward laser control.
The second group, cmPhyStatistics group, represents the
counters that collect error statistics on the received
data traffic for all protocols except SONET.
The error statistics for SONET are covered
in the SONET-MIB.
The third group, cmPhySonetSectionTrace group, provides
objects for section trace monitoring on SONET/SDH
interfaces.
"
REVISION "200411190000Z"
DESCRIPTION
"cmPhyIfTransType object has been added to cmPhyIfTable.
'e1', 't1', 'e3', 't3', 'dvb', 'sdi' and 'its' enumeration
has been added to cmPhyIfProtocol object."
REVISION "200308250000Z"
DESCRIPTION
"cmPhyIfAutoNegotiation object has been added to cmPhyIfTable."
REVISION "200301080000Z"
DESCRIPTION
"cmPhyIfTxBufferSize object has been added to cmPhyIfTable."
REVISION "200205140000Z"
DESCRIPTION
"The third revision of this MIB.
The following new counters have been added -
cmPhyRxCRC,
cmPhyRxCRCOverflow,
cmPhyHCRxCRC,
cmPhyTxEncapFarEndPktErrors,
cmPhyTxEncapFarEndPktErrOverflow,
cmPhyHCTxEncapFarEndPktErrors
The following objects have been deprecated -
cmPhyIfLaserSafetyControl (moved to CISCO-OPTICAL-IF-EXTN-MIB),
cmPhyIfForwardLaserControl (moved to CISCO-OPTICAL-IF-EXTN-MIB),
cmPhyRxPower (moved to CISCO-OPTICAL-MONITOR-MIB),
cmPhyRxHEC (moved to CISCO-CDL-MIB),
cmPhyRxHECOverflow (moved to CISCO-CDL-MIB) and
cmPhyHCRxHEC (moved to CISCO-CDL-MIB).
"
REVISION "200108310000Z"
DESCRIPTION
"The second revision of this MIB."
REVISION "200104190000Z"
DESCRIPTION
"The initial revision of this MIB."
::= { ciscoExperiment 69 } -- assigned by CANA
-- Textual Conventions
TransmissionType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer value that identifies the physical layer medium
used across an interface.
The value 'unknown' indicates the physical layer medium is not
known.
The value 'copper' indicates the physical layer medium is
copper.
The value 'optical' indicates the physical layer medium is
optical."
SYNTAX INTEGER {
unknown(1),
copper(2),
optical(3)
}
ProtocolType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer value that identifies the protocol used across an
interface.
The value 'e1' indicates an interface that implements the
physical layer of E1.
The value 't1' indicates an interface that implements the
physical layer of T1.
The value 'e3' indicates an interface that implements the
physical layer of E3.
The value 't3' indicates an interface that implements the
physical layer of T3.
The value 'dvb' indicates an interface that implements the
physical layer of DVB.
The value 'sdi' indicates an interface that implements the
physical layer of SDI.
The value 'its' indicates an interface that implements the
physical layer of ITS. "
SYNTAX INTEGER {
other(1),
unknown(2),
gigabitEthernet(3),
tenGigabitEthernet(4),
fibreChannel(5),
ficon(6),
escon(7),
sonet(8),
sdh(9),
sysplexIscCompatibility(10),
sysplexIscPeer(11),
sysplexTimerEtr(12),
sysplexTimerClo(13),
fastEthernet(14),
fddi(15),
e1(16),
t1(17),
e3(18),
t3(19),
dvb(20),
sdi(21),
its(22)
}
TriValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A three codepoint value."
SYNTAX INTEGER {
true(1),
false(2),
notApplicable(3)
}
-- MIB Object Definitions
ciscoMetroPhyMIBObjects OBJECT IDENTIFIER ::= { ciscoMetroPhyMIB 1 }
-- groups in this MIB module
cmPhyIf OBJECT IDENTIFIER
::= { ciscoMetroPhyMIBObjects 1 }
cmPhyStatistics OBJECT IDENTIFIER
::= { ciscoMetroPhyMIBObjects 2 }
cmPhySonetSectionTrace OBJECT IDENTIFIER
::= { ciscoMetroPhyMIBObjects 3 }
-- cmPhyIf group
-- This group handles the physical layer related interface
-- configurations, like the protocol and rate used across the client
-- side interface, monitoring of counters, enabling/disabling of OFC,
-- forward laser control, laser safety control and loopback mode
-- across client and trunk side interfaces.
-- PHY If Table
cmPhyIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmPhyIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows physical layer related interface
configurations on an interface."
::= { cmPhyIf 1 }
cmPhyIfEntry OBJECT-TYPE
SYNTAX CmPhyIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects for configuration on an
interface."
INDEX { ifIndex }
::= { cmPhyIfTable 1 }
CmPhyIfEntry ::= SEQUENCE {
cmPhyIfMode INTEGER,
cmPhyIfProtocol ProtocolType,
cmPhyIfClockRate Integer32,
cmPhyIfMonitor TruthValue,
cmPhyIfLoopback INTEGER,
cmPhyIfOFC TruthValue,
cmPhyIfLaserSafetyControl TruthValue,
cmPhyIfForwardLaserControl TruthValue,
cmPhyIfTxBufferSize Unsigned32,
cmPhyIfAutoNegotiation TriValue,
cmPhyIfTransType TransmissionType
}
cmPhyIfMode OBJECT-TYPE
SYNTAX INTEGER {
mode2R(1),
mode3R(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the management client to configure
the mode of operation for the client interface modules.
When in 2R mode, there is no protocol type, clock rate
or monitoring to be configured i.e. the next three
objects would be read-only. When in 3R mode, monitoring
can be enabled or disabled and the clock rate and protocol
should be configured."
::= { cmPhyIfEntry 1 }
cmPhyIfProtocol OBJECT-TYPE
SYNTAX ProtocolType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the protocol of the data
carried over the client side interface.
This object applies to linecards which support a variety of
protocols and allow dynamic configuration of the specific
protocol to be monitored on the interface. The ifType value
for such interfaces remains fixed. The agent may use this
object to identify the protocol to be monitored (see the
cmPhyIfMonitor object), to set the clock rate for the
interface (see the cmPhyIfClockRate object), or to enable
or disable functionality related to the protocol, for
example OFC (see the cmPhyIfOFC object).
The value of this object cannot be modified when the
cmPhyIfMonitor object is set to 'true' for that interface.
Also, this object does not apply to the trunk side
interfaces."
::= { cmPhyIfEntry 2 }
cmPhyIfClockRate OBJECT-TYPE
SYNTAX Integer32 (0..10312000)
UNITS "kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the management client to set the
clock rate across the client side interface.
Due to hardware limitations, all values may not be supported.
The default value of this object depends on the value of the
cmPhyIfProtocol object. When the value of the cmPhyIfProtocol
object is reset, the value of this object will be
automatically set to the default for that protocol.
In case of protocols that support multiple rates,
the default value of this object will be the lowest rate
possible for that protocol. For example, if the value
of cmPhyIfProtocol is set to 'sonet', the default value
of cmPhyIfClockRate is set to the OC-3 rate of 155520 kHz.
If a non-default value is desired, then this object must
be set after the cmPhyIfProtocol object has been reset.
This object must be set to a supported clock rate when
setting cmPhyIfProtocol to 'unknown'.
In 2R mode of operation, this object is not applicable
and will have a default value of 0.
The value of this object cannot be modified when the
cmPhyIfMonitor object is set to 'true' for that interface.
Also, this object is not applicable to trunk side interfaces."
::= { cmPhyIfEntry 3 }
cmPhyIfMonitor OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the management client to enable
monitoring of the error counters on an interface,
by writing a value of 'true' to this object. To bypass
the monitoring hardware, a value of 'false' must be
written to this object.
Monitoring does not apply when the value of
cmPhyIfProtocol is 'unknown'."
::= { cmPhyIfEntry 4 }
cmPhyIfLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoop(1),
diagnosticLoop(2),
lineLoop(3),
otherLoop(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the management client to configure
loopback for the client side or trunk side interfaces.
'noLoop' - No Loopback present.
'diagnosticLoop' - This is an internal loopback, where the
data stream is looped from the transmit
to receive section. It is used for hardware
debug, bring-up and diagnostics.
'lineLoop' - In this mode, the receive data stream is
looped back to the transmit side.
'otherLoop' - This indicates loopbacks not defined here.
The default value of this object will be 'noLoop'."
::= { cmPhyIfEntry 5 }
cmPhyIfOFC OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the management client to enable
OFC(Open Fibre Control) safety protocol for the client
side interfaces, by writing a 'true' value to
this object. A 'false' value would disable OFC.
The default value of this object varies depending on the value
of cmPhyIfProtocol and cmPhyIfClockRate. When cmPhyIfProtocol
or cmPhyIfClockRate is reset, then the value of this object is
automatically reset to the default value for that protocol or
rate. If non-default OFC behavior is desired, then this object
should be set after cmPhyIfProtocol or cmPhyIfClockRate has
been reset.
This object is not applicable to trunk side interfaces."
::= { cmPhyIfEntry 6 }
cmPhyIfLaserSafetyControl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object allows the management client to enable
laser safety control feature on the trunk side interfaces
by writing a true value to this object. If laser safety
control is enabled, the transmit laser on the trunk side is
shut when the receive signal is not available on the fiber.
A 'false' value disables this feature and is the default
value assigned to this object.
Laser safety control would not apply in case of splitter
protection on the optical switch."
::= { cmPhyIfEntry 7 }
cmPhyIfForwardLaserControl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object allows the management client to enable
forward laser control on the client or trunk side interfaces
by writing a true value to this object. If forward laser
control is enabled, the transmit laser is shut when the
cross-connect receive port on the switch is in alarm
condition. A 'false' value disables this feature and is
the default value assigned to this object."
::= { cmPhyIfEntry 8 }
cmPhyIfTxBufferSize OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
UNITS "bytes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object applies when circuit emulation of the client
protocol is used. It allows the management client to
configure the size of the transmit buffer on the client
port. A value of 0 implies that this object does not apply
to this interface.
Controlling the size of the transmit buffer on a client
port may be essential in scenarios where packet streams
from various client ports are aggregated onto a single
trunk port. The latency associated with an elementary
stream received on a client port, from the trunk port is
influenced by the nature of other elementary streams in
the aggregate. For example, a giant packet in one stream
will increase latency in processing packets in other
elementary streams. The size of the transmit buffer on
the client port must be configured proportional to this
expected latency. Increasing the buffer size when latency
is higher helps in reassembly of fragmented packets before
transmitting them to the client device.
Note that increasing the buffer size results in higher
latency even when the elementary packet stream is not
subject to high jitters. Refer to the platform specific
documentation for guidelines on configuring this buffer
size."
::= { cmPhyIfEntry 9 }
cmPhyIfAutoNegotiation OBJECT-TYPE
SYNTAX TriValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the management client to enable
auto negotiation signaling on the client side interface,
by writing a 'true' value to this object. A 'false'
value would disable auto negotiation. Setting the value
'notApplicable' to this object will not change the
existing value in this object.
Auto negotiation is applicable only for a few client
protocols such as gigabitEthernet. If the client
interface does not support 'auto negotiation' feature,
then this object has the value of 'notApplicable' and
the value will not be changed via a set operation."
::= { cmPhyIfEntry 10 }
cmPhyIfTransType OBJECT-TYPE
SYNTAX TransmissionType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to identify the physical layer medium used
for carrying data. For non-relevant interfaces, this value is
'unknown'."
::= { cmPhyIfEntry 11 }
-- cmPhyStatistics group
-- This group contains objects for the error
-- counters for client data traffic, collected by the
-- monitoring hardware.
-- Statistics Table
cmPhyStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmPhyStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the cumulative error statistics being
collected for the different medium types, except SONET,
on the client side and an object for the optical
power level on the trunk side.
The error statistics for SONET are covered
by the sonetSectionCurrentTable and the
sonetSectionIntervalTable in the RFC1595-MIB."
::= { cmPhyStatistics 1 }
cmPhyStatisticsEntry OBJECT-TYPE
SYNTAX CmPhyStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the cmPhyStatisticsTable."
INDEX { ifIndex }
::= { cmPhyStatisticsTable 1 }
CmPhyStatisticsEntry ::= SEQUENCE {
cmPhyRxPower Integer32,
cmPhyRxCVRD Counter32,
cmPhyRxCVRDOverflow Counter32,
cmPhyHCRxCVRD Counter64,
cmPhyRxHEC Counter32,
cmPhyRxHECOverflow Counter32,
cmPhyHCRxHEC Counter64,
cmPhyRxCRC Counter32,
cmPhyRxCRCOverflow Counter32,
cmPhyHCRxCRC Counter64,
cmPhyTxEncapFarEndPktErrors Counter32,
cmPhyTxEncapFarEndPktErrOverflow Counter32,
cmPhyHCTxEncapFarEndPktErrors Counter64
}
cmPhyRxPower OBJECT-TYPE
SYNTAX Integer32 (-4000..0)
UNITS "dBm"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object gives the optical power level received
on the trunk side interface.
The actual value of the power level received on
the interface is the value of this object divided
by 100. This object is not applicable to client side
interfaces.
This object has been deprecated since a similar object
has been defined in the CISCO-OPTICAL-MONITOR-MIB."
::= { cmPhyStatisticsEntry 1 }
cmPhyRxCVRD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the lower word value of the
counter associated with the
number of code violations and running disparity errors
encountered, in the receive direction.
NOTE: The object cmPhyRxCVRDOverflow contains the
higher 32 bits of this counter value. SNMP v2c or v3
managers can use the cmPhyHCRxCVRD object
directly which is a 64 bit counter."
::= { cmPhyStatisticsEntry 2 }
cmPhyRxCVRDOverflow OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the high word value of the
counter associated with the
number of code violations and running disparity errors
encountered, in the receive direction.
NOTE: The object cmPhyRxCVRD contains the lower 32
bits of this counter value. If the error count is
greater than 4,294,967,295 the higher word value
will be stored in this object. SNMP v2c or v3
managers can use the cmPhyHCRxCVRD object
directly which is a 64 bit counter."
::= { cmPhyStatisticsEntry 3 }
cmPhyHCRxCVRD OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the counter associated with the
number of code violations and running disparity errors
encountered, in the receive direction.
This is a High Capacity (64 bit) version of the
cmPhyRxCVRD counter."
::= { cmPhyStatisticsEntry 4 }
cmPhyRxHEC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the lower word value of the
counter associated with the
number of CDL HEC errors encountered, in the receive
direction.
This object has a valid value only if the protocol
type is gigabitEthernet/ tenGigabitEthernet. For all other
protocols, this object is not applicable.
NOTE: The object cmPhyRxHECOverflow contains the
higher 32 bits of this counter value. SNMP v2c or v3
managers can use the cmPhyHCRxHEC object
directly which is a 64 bit counter.
This object has been deprecated since a similar object
has been defined in the CISCO-CDL-MIB."
::= { cmPhyStatisticsEntry 5 }
cmPhyRxHECOverflow OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the high word value of the
counter associated with the number of CDL
HEC errors encountered, in the receive direction.
This object has a valid value only if the protocol
type is gigabitEthernet/ tenGigabitEthernet. For all other
protocols, this object is not applicable.
NOTE: The object cmPhyRxHEC contains the lower 32
bits of this counter value. If the error count is
greater than 4,294,967,295 the higher word value
will be stored in this object. SNMP v2c or v3
managers can use the cmPhyHCRxHEC object
directly which is a 64 bit counter.
This object has been deprecated since a similar object
has been defined in the CISCO-CDL-MIB."
::= { cmPhyStatisticsEntry 6 }
cmPhyHCRxHEC OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the counter associated with the
number of CDL HEC errors encountered, in the receive
direction.
This object has a valid value only if the medium
type is gigabitEthernet/ tenGigabitEthernet. For all other
media, this object is not applicable.
This is a High Capacity (64 bit) version of the
cmPhyRxHEC counter.
This object has been deprecated since a similar object
has been defined in the CISCO-CDL-MIB."
::= { cmPhyStatisticsEntry 7 }
cmPhyRxCRC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the lower word value of the
counter associated with CRC errors.
This object has a valid value only for interfaces that
provide CRC error monitoring.
NOTE: The object cmPhyRxCRCOverflow contains the
higher 32 bits of this counter value. SNMP v2c or v3
managers can use the cmPhyHCRxCRC object
directly which is a 64 bit counter."
::= { cmPhyStatisticsEntry 8 }
cmPhyRxCRCOverflow OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the higher word value of the
counter associated with CRC errors.
This object has a valid value only for interfaces that
provide CRC error monitoring.
NOTE: The object cmPhyRxCRC contains the
lower 32 bits of this counter value. If the error count is
greater than 4,294,967,295 the higher word value
will be stored in this object. SNMP v2c or v3
managers can use the cmPhyHCRxCRC object
directly which is a 64 bit counter."
::= { cmPhyStatisticsEntry 9 }
cmPhyHCRxCRC OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the counter associated with
CRC errors. This object has a valid value only for
interfaces that provide CRC error monitoring.
This is a High Capacity (64 bit) version of the cmPhyRxCRC
counter."
::= { cmPhyStatisticsEntry 10 }
cmPhyTxEncapFarEndPktErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the lower word value of the counter
associated with ingress error indications from the far end of
an Ethernet network, where an ESCON stream is encapsulated in
Ethernet packets. This counter is incremented whenever
an ESCON packet or control character has 8b/10b code
violations or running disparity errors in the ingress
direction at the far end of the Ethernet network.
This object has a valid value only for ESCON interfaces where
Ethernet encapsulation is performed.
NOTE: The object cmPhyTxEncapFarEndPktErrOverflow contains the
higher 32 bits of this counter value. SNMP v2c or v3
managers can use the cmPhyHCTxEsconPktInd object
directly which is a 64 bit counter."
::= { cmPhyStatisticsEntry 11 }
cmPhyTxEncapFarEndPktErrOverflow OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the higher word value of the counter
associated with ingress error indications from the far end of
an Ethernet network, where an ESCON stream is encapsulated in
Ethernet packets. This counter is incremented whenever
an ESCON packet or control character has 8b/10b code
violations or running disparity errors in the ingress
direction at the far end of the Ethernet network.
This object has a valid value only for ESCON interfaces where
Ethernet encapsulation is performed.
NOTE: The object cmPhyTxEncapFarEndPktErrors contains the
lower 32 bits of this counter value. SNMP v2c or v3
managers can use the cmPhyHCTxEsconPktInd object
directly which is a 64 bit counter."
::= { cmPhyStatisticsEntry 12 }
cmPhyHCTxEncapFarEndPktErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the counter associated with ESCON
ingress error indications from the far end of
an Ethernet network, where an ESCON stream is encapsulated in
Ethernet packets. This counter is incremented whenever
an ESCON packet or control character has 8b/10b code
violations or running disparity errors in the ingress
direction at the far end of the Ethernet network.
This object has a valid value only for ESCON interfaces where
Ethernet encapsulation is performed.
This is a High Capacity (64 bit) version of the
cmPhyTxEncapFarEndPktErrors counter."
::={ cmPhyStatisticsEntry 13 }
-- cmPhySonetSectionTrace group
-- This group provides objects for tracing a SONET section
-- by monitoring the J0 bytes of a received SONET or SDH frame.
-- SonetSectionTrace table
cmPhySonetSectionTraceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmPhySonetSectionTraceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides objects for monitoring the J0
bytes of a SONET or SDH section."
::= { cmPhySonetSectionTrace 1 }
cmPhySonetSectionTraceEntry OBJECT-TYPE
SYNTAX CmPhySonetSectionTraceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the cmPhySonetSectionTraceTable is created
when the value of the cmPhyIfProtocol object is set to
'sonet' and the value of cmPhyIfMonitor is set to 'true'."
INDEX { ifIndex }
::= { cmPhySonetSectionTraceTable 1 }
CmPhySonetSectionTraceEntry ::= SEQUENCE {
cmPhySonetSectionTraceReceived OCTET STRING,
cmPhySonetSectionTraceExpected OCTET STRING
}
cmPhySonetSectionTraceReceived OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0|16|64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object displays the SONET or SDH section trace bytes
received at the interface."
::= { cmPhySonetSectionTraceEntry 1 }
cmPhySonetSectionTraceExpected OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0|16|64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the SONET or SDH section trace bytes
to be expected at the interface.
The default value of this object will be a zero length
string."
::= { cmPhySonetSectionTraceEntry 2 }
-- MIB Conformance Statements
ciscoMetroPhyMIBConformance OBJECT IDENTIFIER ::=
{ ciscoMetroPhyMIB 3 }
ciscoMetroPhyMIBCompliances OBJECT IDENTIFIER ::=
{ ciscoMetroPhyMIBConformance 1 }
ciscoMetroPhyMIBGroups OBJECT IDENTIFIER ::=
{ ciscoMetroPhyMIBConformance 2 }
cmPhyMIBCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for platforms that monitor the
operating status with respect to error
counters, for the physical layer."
MODULE -- this module
MANDATORY-GROUPS {
cmPhyIfGroup,
cmPhyStatisticsGroup
}
GROUP cmPhySonetSectionTraceGroup
DESCRIPTION
"Required for entities that support SONET/SDH section
trace."
OBJECT cmPhyIfMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required if only one mode is
supported."
OBJECT cmPhyIfProtocol
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple protocols are supported on the interface."
OBJECT cmPhyIfClockRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple clock rates are supported on the interface."
OBJECT cmPhyIfMonitor
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfOFC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { ciscoMetroPhyMIBCompliances 1 }
cmPhyMIBCompliance2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for platforms that monitor the
operating status with respect to error
counters, for the physical layer."
MODULE -- this module
MANDATORY-GROUPS {
cmPhyIf2Group
}
GROUP cmPhyCVRDErrorsGroup
DESCRIPTION
"Required only for entities that support code violation
and running disparity error counters."
GROUP cmPhyCRCErrorsGroup
DESCRIPTION
"Required only for entities that support
CRC error counters."
GROUP cmPhyEncapFarEndPktErrorsGroup
DESCRIPTION
"Required only for entities that support
far end ingress error indication counters for Ethernet-
encapsulated ESCON streams."
GROUP cmPhySonetSectionTraceGroup
DESCRIPTION
"Required for entities that support SONET/SDH section
trace."
OBJECT cmPhyIfMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required if only one mode is
supported."
OBJECT cmPhyIfProtocol
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple protocols are supported on the interface."
OBJECT cmPhyIfClockRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple clock rates are supported on the interface."
OBJECT cmPhyIfMonitor
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfOFC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { ciscoMetroPhyMIBCompliances 2 }
cmPhyMIBCompliance3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for platforms that monitor the
operating status with respect to error
counters, for the physical layer."
MODULE -- this module
MANDATORY-GROUPS {
cmPhyIf2Group
}
GROUP cmPhyCVRDErrorsGroup
DESCRIPTION
"Required only for entities that support code violation
and running disparity error counters."
GROUP cmPhyCRCErrorsGroup
DESCRIPTION
"Required only for entities that support
CRC error counters."
GROUP cmPhyEncapFarEndPktErrorsGroup
DESCRIPTION
"Required only for entities that support
far end ingress error indication counters for Ethernet-
encapsulated ESCON streams."
GROUP cmPhySonetSectionTraceGroup
DESCRIPTION
"Required for entities that support SONET/SDH section
trace."
GROUP cmPhyIfTxBufferSizeGroup
DESCRIPTION
"Required for entities that support control of transmit
buffer size."
OBJECT cmPhyIfMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required if only one mode is
supported."
OBJECT cmPhyIfProtocol
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple protocols are supported on the interface."
OBJECT cmPhyIfClockRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple clock rates are supported on the interface."
OBJECT cmPhyIfMonitor
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfOFC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfTxBufferSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { ciscoMetroPhyMIBCompliances 3 }
cmPhyMIBComplianceRev4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for platforms that monitor the
operating status with respect to error
counters, for the physical layer."
MODULE -- this module
MANDATORY-GROUPS {
cmPhyIf2Group
}
GROUP cmPhyCVRDErrorsGroup
DESCRIPTION
"Required only for entities that support code violation
and running disparity error counters."
GROUP cmPhyCRCErrorsGroup
DESCRIPTION
"Required only for entities that support
CRC error counters."
GROUP cmPhyEncapFarEndPktErrorsGroup
DESCRIPTION
"Required only for entities that support
far end ingress error indication counters for Ethernet-
encapsulated ESCON streams."
GROUP cmPhySonetSectionTraceGroup
DESCRIPTION
"Required for entities that support SONET/SDH section
trace."
GROUP cmPhyIfTxBufferSizeGroup
DESCRIPTION
"Required for entities that support control of transmit
buffer size."
GROUP cmPhyIfAutoNegGroup
DESCRIPTION
"Required for entities that support auto negotiation
on the client interface."
OBJECT cmPhyIfMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required if only one mode is
supported."
OBJECT cmPhyIfProtocol
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple protocols are supported on the interface."
OBJECT cmPhyIfClockRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple clock rates are supported on the interface."
OBJECT cmPhyIfMonitor
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfOFC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfTxBufferSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfAutoNegotiation
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { ciscoMetroPhyMIBCompliances 4 }
cmPhyMIBComplianceRev5 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for platforms that monitor the
operating status with respect to error
counters, for the physical layer."
MODULE -- this module
MANDATORY-GROUPS {
cmPhyIf2Group
}
GROUP cmPhyCVRDErrorsGroup
DESCRIPTION
"Required only for entities that support code violation
and running disparity error counters."
GROUP cmPhyCRCErrorsGroup
DESCRIPTION
"Required only for entities that support
CRC error counters."
GROUP cmPhyEncapFarEndPktErrorsGroup
DESCRIPTION
"Required only for entities that support
far end ingress error indication counters for Ethernet-
encapsulated ESCON streams."
GROUP cmPhySonetSectionTraceGroup
DESCRIPTION
"Required for entities that support SONET/SDH section
trace."
GROUP cmPhyIfTxBufferSizeGroup
DESCRIPTION
"Required for entities that support control of transmit
buffer size."
GROUP cmPhyIfAutoNegGroup
DESCRIPTION
"Required for entities that support auto negotiation
on the client interface."
GROUP cmPhyIfGroupSup1
DESCRIPTION
"Required for entities that have different transmission
types on the client interface."
OBJECT cmPhyIfMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required if only one mode is
supported."
OBJECT cmPhyIfProtocol
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple protocols are supported on the interface."
OBJECT cmPhyIfClockRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only when 3R mode is supported
and multiple clock rates are supported on the interface."
OBJECT cmPhyIfMonitor
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfOFC
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfTxBufferSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cmPhyIfAutoNegotiation
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { ciscoMetroPhyMIBCompliances 5 }
--
-- units of conformance
--
cmPhyIfGroup OBJECT-GROUP
OBJECTS {
cmPhyIfMode,
cmPhyIfProtocol,
cmPhyIfClockRate,
cmPhyIfMonitor,
cmPhyIfLoopback,
cmPhyIfOFC,
cmPhyIfLaserSafetyControl,
cmPhyIfForwardLaserControl
}
STATUS deprecated
DESCRIPTION
"The collection of objects to allow configurations and give
information related to the physical layer characteristics
of an interface."
::= { ciscoMetroPhyMIBGroups 1 }
cmPhyStatisticsGroup OBJECT-GROUP
OBJECTS {
cmPhyRxPower,
cmPhyRxCVRD,
cmPhyRxCVRDOverflow,
cmPhyHCRxCVRD,
cmPhyRxHEC,
cmPhyRxHECOverflow,
cmPhyHCRxHEC
}
STATUS deprecated
DESCRIPTION
"The collection of objects used to monitor the protocol
error counters on the client side and the power level
received on the trunk side."
::= { ciscoMetroPhyMIBGroups 2 }
cmPhySonetSectionTraceGroup OBJECT-GROUP
OBJECTS {
cmPhySonetSectionTraceReceived,
cmPhySonetSectionTraceExpected
}
STATUS current
DESCRIPTION
"The objects used for monitoring the SONET section
trace bytes."
::= { ciscoMetroPhyMIBGroups 3 }
cmPhyIf2Group OBJECT-GROUP
OBJECTS {
cmPhyIfMode,
cmPhyIfProtocol,
cmPhyIfClockRate,
cmPhyIfMonitor,
cmPhyIfLoopback,
cmPhyIfOFC
}
STATUS current
DESCRIPTION
"The collection of objects to allow configurations and give
information related to the physical layer characteristics
of an interface."
::= { ciscoMetroPhyMIBGroups 4 }
cmPhyCVRDErrorsGroup OBJECT-GROUP
OBJECTS {
cmPhyRxCVRD,
cmPhyRxCVRDOverflow,
cmPhyHCRxCVRD
}
STATUS current
DESCRIPTION
"The collection of objects used to monitor the code violation
and running disparity error counters."
::= { ciscoMetroPhyMIBGroups 5 }
cmPhyCRCErrorsGroup OBJECT-GROUP
OBJECTS {
cmPhyRxCRC,
cmPhyRxCRCOverflow,
cmPhyHCRxCRC
}
STATUS current
DESCRIPTION
"The collection of objects used to monitor CRC
error counters."
::= { ciscoMetroPhyMIBGroups 6 }
cmPhyEncapFarEndPktErrorsGroup OBJECT-GROUP
OBJECTS {
cmPhyTxEncapFarEndPktErrors,
cmPhyTxEncapFarEndPktErrOverflow,
cmPhyHCTxEncapFarEndPktErrors
}
STATUS current
DESCRIPTION
"The collection of objects used to monitor the
far end ingress error indication counters for Ethernet-
encapsulated ESCON streams."
::= { ciscoMetroPhyMIBGroups 7 }
cmPhyIfTxBufferSizeGroup OBJECT-GROUP
OBJECTS {
cmPhyIfTxBufferSize
}
STATUS current
DESCRIPTION
"The collection of objects used to control size of
transmit buffer."
::= { ciscoMetroPhyMIBGroups 8 }
cmPhyIfAutoNegGroup OBJECT-GROUP
OBJECTS {
cmPhyIfAutoNegotiation
}
STATUS current
DESCRIPTION
"The collection of objects used to control auto
negotiation behavior."
::= { ciscoMetroPhyMIBGroups 9 }
cmPhyIfGroupSup1 OBJECT-GROUP
OBJECTS {
cmPhyIfTransType
}
STATUS current
DESCRIPTION
"The object that gives information related to transmission
types on the client interface."
::= { ciscoMetroPhyMIBGroups 10 }
END