snmp_mib_archive/CISCO-ITP-GSP-MIB.my
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

6240 lines
211 KiB
Plaintext

-- *****************************************************************
-- CISCO-ITP-GSP-MIB: Itp Signalling Point
--
-- August 2002, John Linton, Shekhar Acharya
--
-- Copyright (c) 2002-2003, 2005, 2008-2010 by Cisco Systems Inc.
-- All rights reserved.
-- *****************************************************************
CISCO-ITP-GSP-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter32,
Integer32,
Gauge32,
MODULE-IDENTITY,
NOTIFICATION-TYPE,
OBJECT-TYPE,
Unsigned32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
NOTIFICATION-GROUP,
OBJECT-GROUP
FROM SNMPv2-CONF
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
InetAddressType,
InetAddress,
InetPortNumber
FROM INET-ADDRESS-MIB
InterfaceIndexOrZero
FROM IF-MIB
RowStatus,
TimeStamp,
TruthValue,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
CItpTcAclId,
CItpTcCLLI,
CItpTcDisplayPC,
CItpTcInstanceNumber,
CItpTcLinksetId,
CItpTcNetworkName,
CItpTcLinkSLC,
CItpTcLinkType,
CItpTcNetworkIndicator,
CItpTcPointCode,
CItpTcPointCodeType,
CItpTcQos,
CItpTcRouteTableName,
CItpTcServiceIndicator
FROM CISCO-ITP-TC-MIB
ciscoMgmt
FROM CISCO-SMI;
ciscoGspMIB MODULE-IDENTITY
LAST-UPDATED "201003050000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Cisco Systems, Inc
Customer Service
Postal: 170 W. Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-ss7@cisco.com"
DESCRIPTION
"The MIB for managing Signalling Points and its
associated messages transported over Signalling
System No. 7 (SS7) Network via Cisco IP Transfer
Point. This MIB replaces the CISCO-ITP-SP-MIB and
provide support multiple instances of a signalling
point within same configuration.
The Cisco IP Transfer Point (ITP) is a hardware
and software solution that transports SS7 traffic
using IP. Each ITP node provides function similar
to SS7 Signalling point.
The relevant ITU documents describing this technology
is the ITU Q series, including ITU Q.700: Introduction
to CCITT Signalling System No. 7 and ITU Q.701
Functional description of the message transfer part
(MTP) of Signalling System No. 7.
This MIB models the GSP as follows:
Abbreviations:
AERM - Alignment Error Rate Monitor
CLLI - Common-Language Location Identification
DPC - Destination Point Code
GSP - Gateway Signalling Point
HSL - High Speed Link (ATM based)
LLSC - link set control
LSAC - Signalling link activity control
LSDA - Signalling data link allocation
LSLA - Signalling link activation
LSLD - Signalling link deactivation
LSLR - Signalling link restoration
LSSU - Link Status Signal Unit
LSTA - Signalling terminal allocation
MTP - Message Transport Protocol
MTP2 - Layer 2 of Message Transport Protocol
MTP3 - Layer 3 of Message Transport Protocol
NTT - The Japanese Nippon Telephone & Telegraph
OPC - Originating Point Code
PC - Point Code
RTN - RouteTableName
SCTP - Stream Transmission Protocol(RFC 2960)
SIB - Status Indicator Busy
SLT - Signalling Link Test
SLTA - Signalling Link Test Acknowledgement
SP - Signalling Point
SS7 - System No. 7 (SS7) Network
SUERM - Signal Unit Error Rate Monitor
TCBC - Changeback control
TCOC - Changeover control
TCRC - Controlled rerouting control
TFRC - Forced rerouting control
TLAC - Link availability control
TPRC - Signalling point restart control
TRCC - Signalling route set congestion control
TSFC - Signalling traffic flow control
TSRC - Signalling routing control
TTC - The Japanese Telecommunications Technology
Committee
WRR - Weighted round robin"
REVISION "200912310000Z"
DESCRIPTION
"Added the cgspLinkRxCongestionState object into CgspLinkTableEntry and
ciscoGspRxCongestionChange notification to notify state of cgspLinkRxCongestionState."
REVISION "200909120000Z"
DESCRIPTION
"Added the opc value to the cgspInstSccpWrrOption textual convention."
REVISION "200905250000Z"
DESCRIPTION
"Added the following objects into cgspInstanceTableEntry
for GTT weighted loadshare.
cgspInstSccpWrrOpcShift,
cgspInstSccpWrrOption"
REVISION "200805070000Z"
DESCRIPTION
"Added the following objects into CgspLinkTableEntry
for additional Q752 related reporting.
cgspLinkQ752T1E12,
cgspLinkQ752T1E12Errors,
cgspLinkQ752T2E11,
cgspLinkQ752T2E17,
cgspLinkQ752T2E19.
Added linkRestored(34) and linkTestFailure(35) reason code to the
cgspLinkReason object.
Added the following textual convention:
CgspDisplayInstanceUserPart.
Added a new table cgspInstUPUTable with following objects:
cgspMtp3SI, cgspInstSIUPUReceived, cgspInstSIUPUTransmitted,
cgspInstUserPartDisplay.
Added the following objects:
cgspNotificationsInfo, cgspUPUNotifWindowTime.
Added following new notifications:
ciscoGspUPUReceived, ciscoGspUPUTransmitted.
Added the following cgspNotificationsInfo objects:
cgspUPUIntervalDuration, cgspIntervalUPUs."
REVISION "200510210000Z"
DESCRIPTION
"Added new set of enums (from timerMtp2T01 to
timerMtp2T07) to TC CgspTimerNumbers for
MTP2 timers specified in ITU Q.703."
REVISION "200502240000Z"
DESCRIPTION
"Added new ciscoGspIsolation notification to indicate
when MTP3 node becomes isolated."
REVISION "200307160000Z"
DESCRIPTION
"Additional reason codes to the cgspLinkReason object
and updated CgspSS7Variant textual convention to
support NTT and TTC Japanese variants. Also, update
REFERENCE clauses to indicate support for appropriate
ANSI standard."
REVISION "200303030000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { ciscoMgmt 336 }
-- Top-level structure of the MIB
ciscoGspMIBNotifs OBJECT IDENTIFIER
::= { ciscoGspMIB 0 }
ciscoGspMIBObjects OBJECT IDENTIFIER
::= { ciscoGspMIB 1 }
ciscoGspMIBConform OBJECT IDENTIFIER
::= { ciscoGspMIB 2 }
cgspScalars OBJECT IDENTIFIER
::= { ciscoGspMIBObjects 1 }
cgspProfile OBJECT IDENTIFIER
::= { ciscoGspMIBObjects 2 }
cgspInstance OBJECT IDENTIFIER
::= { ciscoGspMIBObjects 3 }
cgspPointCode OBJECT IDENTIFIER
::= { ciscoGspMIBObjects 4 }
cgspLinkset OBJECT IDENTIFIER
::= { ciscoGspMIBObjects 5 }
cgspLink OBJECT IDENTIFIER
::= { ciscoGspMIBObjects 6 }
cgspNotificationsEnable OBJECT IDENTIFIER
::= { ciscoGspMIBObjects 7 }
cgspNotificationsInfo OBJECT IDENTIFIER
::= { ciscoGspMIBObjects 8 }
-- **************************************************************
-- * *
-- * Textual Conventions *
-- * *
-- **************************************************************
CgspSequenceNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention defines all of the allowed
values for a sequence of integers used by the
SS7 protocol to transmit and acknowledge packets.
The range is specified from 0 to maximum allowed
value for extended sequence numbers. The actual
range will depend on the type of link and
the variant. The value will increase and then wrap
to the zero value. The following are examples of
valid sequences.
0..126,127,0..
0..254,255,0..
0..32766,32767,0..
0..65534,65535,0..
Therefore, the sequence number will behave like
a counter with range appropriate for the type of
link."
SYNTAX Unsigned32 (0..65535)
CgspSampleInterval ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention defines the allowed values
for a sample interval. This value is specified in
seconds and ranges from 1 minute to 1 hour."
SYNTAX Unsigned32 (60..3600)
CgspPercentThreshold ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention defines the allowed values
used to define a threshold. This value is
specified as percentage of link utilization. A
value of zero indicates that this specific
threshold is to be ignored."
SYNTAX Unsigned32 (0..100)
CgspLinkTestResults ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This object provides information on result from
signalling link test procedures as follows.
'noErrors' : Link test did not detect any errors.
'undefinedOpc' : A signalling link test message was
received with an undefined originating
point code.
'incorrectOpc' : A signalling link test message was
received with an incorrect originating
point code.
'undefinedSlc' : A signalling link test message was
received with an undefined signalling
link code.
'incorrectSlc' : A signalling link test message was
received with an incorrect signalling
link code..
'incorrectNi' : A signalling link test message was
received with an incorrect Network
Indicator.
'badPattern' : A signalling link test message was
received with an incorrect test
pattern. This may be caused by variant
mismatched or incorrect definitions
on physical link.
'nonAdjacent' :Received a signalling link test message
from an non-adjacent node.
'failed' :Unable to run test or no response was
received within the specified interval."
SYNTAX INTEGER {
noErrors(0),
undefinedOpc(1),
incorrectOpc(2),
undefinedSlc(3),
incorrectSlc(4),
incorrectNi(5),
badPattern(6),
nonAdjacent(7),
failed(8)
}
CgspLinkUtilization ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention defines a range of values
that represent a link's utilization during an
interval of time. The values expressed as a
percent of link capacity. Any value over 999 will
be represented as 999.
For SS7 links based on IP/SCTP the link capacity
is not directly related to the interface speed used
to transmit packets. This is different from serial
and HSL links. The capacity of these types of
links depend on the amount of resources available
in the IP cloud. The IP cloud must be provisioned
to support traffic for all SS7 links. In order to
monitor link utilization on IP/SCTP based SS7 links
a planned capacity must be specified. If this value
is incorrectly estimated or traffic exceeds this
expected value link utilization may exceed 100
percent. This is possible because the IP cloud
may be provisioned with additional capacity or
may discard less important traffic based on QoS
parameters.
When a SS7 link has not be configured for link
utilization monitoring this value object will
have a value of zero."
SYNTAX Gauge32 (0..999)
CgspLinkCapacity ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This textual convention defines the planned
capacity of a SS7 link in bit per second.
When the cgspLinkType object is 'sctpIp' or
'hsl' the link capacity can be obtained from
information in the IF-MIB.
When the cgspLinkType object is 'sctpIp' a
value of zero indicates that link utilization
should not be calculated for this SS7 link."
SYNTAX Unsigned32 (0..0 | 56000..2147483647)
CgspProfileName ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The configured name associated with a Signalling
Point Profile.
An octet string specified by an administrator that must
be in human-readable form. The names must conform to
the allowed characters that can be specified via
Command Line Interface(CLI). The names cannot contain
control character and should not contain leading or
trailing white space."
SYNTAX OCTET STRING (SIZE (0..19))
CgspLinkUtilizationState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Link Utilization State as follows:
'unMonitored' - traffic for a specified direction
is not being monitored.
'underThreshold' - traffic for a specified direction
on a link is below the specified
threshold.
'overThreshold' - traffic for a specified direction
on a link is above to or exceeds
the specified threshold."
SYNTAX INTEGER {
unMonitored(0),
underThreshold(1),
overThreshold(2)
}
CgspTimerNumbers ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerated values for all timers"
SYNTAX INTEGER {
timerMtp3T01(1), -- Delay to avoid message
-- mis-sequencing on changeover.
timerMtp3T02(2), -- Waiting for changeover
-- acknowledgement.
timerMtp3T03(3), -- Time controlled
-- diversion-delay to avoid
-- mis-sequencing on change back.
timerMtp3T04(4), -- Waiting for change back
-- acknowledgement (first
-- attempt).
timerMtp3T05(5), -- Waiting for change back
-- acknowledgement (second
-- attempt)
timerMtp3T06(6), -- Delay to avoid message
-- mis-sequencing on controlled
-- rerouting
timerMtp3T07(7), -- Waiting for signalling data
-- link connection
-- acknowledgement
timerMtp3T08(8), -- Transfer prohibited inhibition
-- timer (transient solution)
timerMtp3T09(9), -- Reserved
timerMtp3T10(10), -- Waiting to repeat signalling
-- routeset test message
timerMtp3T11(11), -- Transfer restricted timer
timerMtp3T12(12), -- Waiting for uninhibit
-- acknowledgement
timerMtp3T13(13),
timerMtp3T14(14), -- Waiting for inhibition
-- acknowledgement
timerMtp3T15(15), -- Waiting to start signalling
-- routeset congestion
timerMtp3T16(16), -- Waiting for routeset
-- congestion status update
timerMtp3T17(17), -- Delay to avoid oscillation of
-- initial alignment failure and
-- link restart
timerMtp3T18(18), -- ANSI: Repeat TFR once by
-- response method ITU: MTP
-- restart link supervision
timerMtp3T19(19), -- ANSI: failed craft timer
-- referral timer ITU:
-- supervision timer during MTP
-- restart
timerMtp3T20(20), -- ANSI: waiting to repeat local
-- inhibit test ITU: MTP restart
-- timer at the signalling point
timerMtp3T21(21), -- ANSI: waiting to repeat
-- remote inhibit test) ITU: MTP
-- restart timer at adjacent
-- signalling point
timerMtp3T22(22), -- ANSI: restarting SP waiting
-- for signalling links avail
-- ITU: local inhibit test timer
timerMtp3T23(23), -- ANSI: restarting SP waiting
-- to receive all TRA msgs ITU:
-- remote inhibit test timer
timerMtp3T24(24), -- ANSI: restarting SP waiting
-- to broadcast all TRA msgs
-- ITU: stabilizing timer after
-- local processor outage
timerMtp3T25(25), -- Timer at Signalling Point
-- (SP) adjacent to restarting
-- Signalling Point, waiting for
-- traffic restart allowed
-- message.
timerMtp3T26(26), -- Timer at restarting SP
-- waiting to repeat traffic
-- restart waiting message.
timerMtp3T27(27), -- Minimum duration of
-- unavailability for full
-- restart
timerMtp3T28(28), -- Timer at SP adjacent to
-- restarting SP waiting for
-- traffic restart waiting
-- message
timerMtp3T29(29), -- Timer started when TRA sent
-- in response to unexpected TRA
-- or TRW
timerMtp3T30(30), -- Timer to limit sending of
-- TFPs and TFRs in response to
-- unexpected TRA or TRW
timerMtp3T31(31), -- False link congestion
-- detection timer
timerMtp3T32(32), -- Link oscillation timer -
-- Procedure A
timerMtp3T33(33), -- Probation timer for link
-- oscillation - Procedure B
timerMtp3T34(34), -- Suspension timer for link
-- oscillation - Procedure B
timerLinkTest(35), -- Signalling Link Test
-- Acknowledgement timer
timerLinkMessag1(36), -- Interval timer for
-- sending test messages
timerLinkActRetry(37), -- Link activation retry
-- timer.
timerMtp2T01(38), -- Link alignment ready timer
timerMtp2T02(39), -- Link not aligned timer
timerMtp2T03(40), -- Link aligned timer
timerMtp2T04N(41), -- Link proving normal timer
timerMtp2T04E(42),
timerMtp2T05(43), -- Sending SIB timer
timerMtp2T06(44), -- Remote congestion timer
timerMtp2T07(45)
}
CgspTimerValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Value of timers in milliseconds as follows. A value of zero
indicates that the timer is not applicable for variant or
link type. The values specified in this textual convention
apply to the various timers identified in CgspTimerNumbers
textual convention.
ANSI ITU
Min Max Def Min Max Def
------ ------ ------ ------ ------ ------
TimerMtp3T01 500 1200 800 500 1200 800
TimerMtp3T02 700 2000 1400 700 2000 1400
TimerMtp3T03 500 1200 800 500 1200 800
TimerMtp3T04 500 1200 800 500 1200 800
TimerMtp3T05 500 1200 800 500 1200 800
TimerMtp3T06 500 1200 800 500 1200 800
TimerMtp3T07 1000 2000 1500 1000 2000 1500
TimerMtp3T08 800 1200 1000 800 1200 1000
TimerMtp3T10 30000 60000 45000 30000 60000 45000
TimerMtp3T11 30000 90000 60000 30000 90000 60000
TimerMtp3T12 800 1500 1150 800 1500 1150
TimerMtp3T13 800 1500 1150 800 1500 1150
TimerMtp3T14 2000 3000 2500 2000 3000 2500
TimerMtp3T15 2000 3000 2500 2000 3000 2500
TimerMtp3T16 1400 2000 1700 1400 2000 1700
TimerMtp3T17 800 1500 1150 800 1500 1150
TimerMtp3T18 2000 20000 11000 1000 31000 30000
TimerMtp3T19 480000 600000 540000 67000 69000 68000
TimerMtp3T20 90000 120000 105000 1000 61000 60000
TimerMtp3T21 90000 120000 105000 63000 65000 64000
TimerMtp3T22 36000 60000 30000 80000 360000 300000
TimerMtp3T23 9000 60000 30000 80000 360000 300000
TimerMtp3T24 9000 60000 30000 500 500 500
TimerMtp3T25 30000 35000 30000 n/a n/a n/a
TimerMtp3T26 12000 15000 12000 n/a n/a n/a
TimerMtp3T27 2000 50000 4000 n/a n/a n/a
TimerMtp3T28 3000 35000 30000 n/a n/a n/a
TimerMtp3T29 60000 65000 63000 n/a n/a n/a
TimerMtp3T30 30000 35000 33000 n/a n/a n/a
TimerMtp3T31 10000 120000 60000 n/a n/a n/a
TimerMtp3T32 5000 120000 60000 n/a n/a n/a
TimerMtp3T33 60000 600000 300000 n/a n/a n/a
TimerMtp3T34 5000 120000 60000 n/a n/a n/a
TimerLinkTest 4000 12000 8000 n/a n/a n/a
TimerLinkMessage 30000 90000 60000 n/a n/a n/a
TimerLinkActRetry 60000 90000 60000 n/a n/a n/a"
REFERENCE
"ITU Q.703 Signalling Link.
ANSI T1.111.3 Telecommunications - signalling system
No. 7 (SS7)-Message Transfer Part (MTP)."
SYNTAX Unsigned32 (0..0 | 1..4294967295)
CgspSS7Variant ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The list of SS7 variants.
'unknown' : Unknown or undefined variant.
'ANSI' : The ANSI variant of the SS7 specification.
'ITU' : The ITU variant of the SS7 specification.
'China' : The China national variant. This variant
is a combination of ITU and ANSI. The
protocol matches ITU except where the
point-code has been expanded to ANSI format.
'NTT' : The Japanese Nippon Telephone & Telegraph
variant.
'TTC' : The Japanese Telecommunications Technology
Committee variant."
REFERENCE
"GF 001-9001 - Technical Specifications of Signalling
System No. 7 for National Telephone Network of China."
SYNTAX INTEGER {
unknown(0),
ansi(1),
itu(2),
china(3),
ntt(4),
ttc(5)
}
CgspDisplayInstanceUserPart ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The instance name and user part information
formatted for display. If instance name is not
configured, the default local point code in
ASCII string format will be provided as instance
name."
SYNTAX OCTET STRING (SIZE (0..40))
CItpTcSccpWrrOption ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The possible options for calculate sccp class1 traffic
loadshare when GTT application group's multiplicity mode
is WRR(Weighted round robin):
'sls' : Use sls to calculate loadsharing
'cgpaSls' : Use the combination of cgpa and sls to calculate loadsharing
'opcSls' : Use the combination of opc and sls to calculate loadsharing
'opc' : Use the opc to caculate loadsharing"
SYNTAX INTEGER {
sls(0),
cgpaSls(1),
opcSls(2),
opc(3)
}
-- *************************************************************
-- * *
-- * GSP - Scalar *
-- * *
-- *************************************************************
cgspCLLICode OBJECT-TYPE
SYNTAX CItpTcCLLI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Common-Language Location Identification Codes
(CLLI Codes). This object identifies the
physical location of this device and can provide
additional informaton on the device type."
::= { cgspScalars 1 }
cgspUtilSampleInterval OBJECT-TYPE
SYNTAX CgspSampleInterval
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the time interval used to monitor
the utilization of SS7 links. This object in combination
with cgspUtilThreshold, cgspLinkPlanCapacitySent and
cgspLinkPlanCapacityRcvd will be used to calculate
utilization of SS7 links. Changes to the polling interval
will take effect after the completion of the current
sample interval."
DEFVAL { 300 }
::= { cgspScalars 2 }
cgspUtilThreshold OBJECT-TYPE
SYNTAX CgspPercentThreshold
UNITS "percent"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the threshold of usage for all
SS7 links in SP. This object is used to determine when
to generate the ciscoGspLinkRcvdUtilChange or
ciscoGspLinkSentUtilChange notifications.
A value of zero indicates that no default threshold
is specified. Therefore, only links with non-zero
values for cgspLinkUtilThresholdRcvd or
cgspLinkUtilThresholdSent will generate notifications
based on link utilization.
Changes to the utilization threshold will take effect
at the end of the current interval."
DEFVAL { 40 }
::= { cgspScalars 3 }
cgspUtilAbateDelta OBJECT-TYPE
SYNTAX CgspPercentThreshold
UNITS "percent"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the falling threshold to be lower
than the rising threshold when calculating whether to
generate the ciscoGspLinkRcvdUtilChange or
ciscoGspLinkSentUtilChange notifications. This is done
to prevent generating notifications for slight changes
in traffic."
DEFVAL { 0 }
::= { cgspScalars 4 }
cgspPlanCapacityDefault OBJECT-TYPE
SYNTAX CgspLinkCapacity
UNITS "bits per second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides a default for value for links
with a cgspLinkType='sctpIp'. For all other types
of linkset this value is ignored. When a linkset
based on SCTP/IP and the values for the
cgspLinkPlanCapacityRcvd or cgspLinkPlanCapacitySent
object are zero then this object will be used
as the default. A value of zero indicates that
a global default has not been specified.
This object will be used in combination with
cgspUtilSampleInterval, cgspUtilThreshold, cgspUtilThreshold
and cgspLinkUtilThresholdRcvd to generate the
ciscoGspLinkRcvdUtilChange notification."
::= { cgspScalars 5 }
cgspEventSequenceNumber OBJECT-TYPE
SYNTAX Counter32
UNITS "events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each event or notification is required to provide a
sequence number to be used by the NMS to determine when
messages from a particular device are missing. This value
will included in each SS7 notification issued by this device."
REFERENCE "GR-82-CORE 6.6.1 Event Report Content R6-33"
::= { cgspScalars 6 }
cgspUPUNotifWindowTime OBJECT-TYPE
SYNTAX Integer32 (60..86400)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the time interval used to monitor
the ciscoGspUPUReceived and ciscoGspUPUTransmitted
notifications for specific user part and signalling point
instance. The first occurrence of ciscoGspUPUReceived and
ciscoGspUPUTransmitted notifications are sent and the
further occurrences of notifications in this interval
are suppressed.
At the end of this interval, a notification is sent with
total number of UPU MSUs transmitted or received during
this interval."
DEFVAL { 900 }
::= { cgspScalars 7 }
-- *************************************************************
-- * *
-- * Profile Table *
-- * *
-- *************************************************************
cgspProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspProfileTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the Profiles of signalling
points. Entries are added to this table via
cgspProfileRowStatus in accordance with the RowStatus
convention."
::= { cgspProfile 1 }
cgspProfileTableEntry OBJECT-TYPE
SYNTAX CgspProfileTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Profile attributes. Profiles are
used to specify common configuration options for
SS7 links without customizing each link.
A profile is created with the specified values
using this table and the cgspProfileTimerTable
Table. The common values are applied to all
links in a linkset by specifying the
cgspLinksetProfileName on the linkset."
INDEX { cgspProfileName }
::= { cgspProfileTable 1 }
CgspProfileTableEntry ::= SEQUENCE {
cgspProfileName CgspProfileName,
cgspProfileVariant CgspSS7Variant,
cgspProfileMtp2BundleTimer Integer32,
cgspProfileMtp2SendQueueDepth Integer32,
cgspProfileRowStatus RowStatus
}
cgspProfileName OBJECT-TYPE
SYNTAX CgspProfileName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Name of the profile."
::= { cgspProfileTableEntry 1 }
cgspProfileVariant OBJECT-TYPE
SYNTAX CgspSS7Variant
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The SS7 variant used to format data specified in this
profile."
::= { cgspProfileTableEntry 2 }
cgspProfileMtp2BundleTimer OBJECT-TYPE
SYNTAX Integer32 (0..0 | 5..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Bundle timer value. This value is used to control
the bundling of SS7 packets as they are transported
within the device. The value of zero indicates that
MTP3 packets will not be bundled for transmission
as they arrival for transmission at the MTP2 layer.
A non-zero value specifies the maximum delay time
used to collect MTP3 packets before they are
transmitted by the MTP2 layer."
::= { cgspProfileTableEntry 3 }
cgspProfileMtp2SendQueueDepth OBJECT-TYPE
SYNTAX Integer32 (25..32000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum Queue depth allowed per link for
MTP2 waiting to be transmitted."
::= { cgspProfileTableEntry 4 }
cgspProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to
create or delete the row entry in cgspProfileTable
following the RowStatus textual convention."
::= { cgspProfileTableEntry 5 }
-- *************************************************************
-- * *
-- * Profile Timer Table *
-- * *
-- *************************************************************
cgspProfileTimerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspProfileTimerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains a profile of timers used to
configure SS7 links. Entries are added to this table
via cgspProfileTimerRowStatus in accordance with the
RowStatus convention."
::= { cgspProfile 2 }
cgspProfileTimerTableEntry OBJECT-TYPE
SYNTAX CgspProfileTimerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of ProfileTimer attributes. Profiles are
used to specify common timer configuration options
for SS7 links without customizing each link.
A profile is created with the specified values
using this table and the cgspProfileTable
Table. The common values are applied to all
links in a linkset by specifying the
cgspLinksetProfileName on the linkset."
INDEX {
cgspInstNetwork,
cgspProfileTimerNumber
}
::= { cgspProfileTimerTable 1 }
CgspProfileTimerTableEntry ::= SEQUENCE {
cgspProfileTimerNumber CgspTimerNumbers,
cgspProfileTimerValue CgspTimerValue,
cgspProfileTimerRowStatus RowStatus
}
cgspProfileTimerNumber OBJECT-TYPE
SYNTAX CgspTimerNumbers
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into table containing timer information."
::= { cgspProfileTimerTableEntry 1 }
cgspProfileTimerValue OBJECT-TYPE
SYNTAX CgspTimerValue
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of timer selected by cgspProfileTimerNumber object."
::= { cgspProfileTimerTableEntry 2 }
cgspProfileTimerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to
create or delete the row entry in cgspProfileTimerTable
following the RowStatus textual convention."
::= { cgspProfileTimerTableEntry 3 }
-- *************************************************************
-- * *
-- * Instance Table *
-- * *
-- *************************************************************
cgspInstanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspInstanceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the instances of signalling
points. Entries are added to this table via
cgspInstRowStatus in accordance with the RowStatus
convention."
::= { cgspInstance 1 }
cgspInstanceTableEntry OBJECT-TYPE
SYNTAX CgspInstanceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of instance attributes."
INDEX { cgspInstNetwork }
::= { cgspInstanceTable 1 }
CgspInstanceTableEntry ::= SEQUENCE {
cgspInstNetwork CItpTcNetworkName,
cgspInstNetworkIndicator CItpTcNetworkIndicator,
cgspInstVariant CgspSS7Variant,
cgspInstDisplayName SnmpAdminString,
cgspInstDescription SnmpAdminString,
cgspInstTFR TruthValue,
cgspInstCongestionsLevels TruthValue,
cgspInstFastRestart TruthValue,
cgspInstDistSccpUnseq TruthValue,
cgspInstSummaryRoutingException TruthValue,
cgspInstNumber CItpTcInstanceNumber,
cgspInstRouteTableName CItpTcRouteTableName,
cgspInstRowStatus RowStatus,
cgspInstSccpWrrOpcShift Unsigned32,
cgspInstSccpWrrOption CItpTcSccpWrrOption
}
cgspInstNetwork OBJECT-TYPE
SYNTAX CItpTcNetworkName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network name is used to indicate the network
in which this signalling point is participating.
One or more instances of signalling points can
exist in the same physical device. This identifier
will be used to correlate instances of signalling
points by network.
When multiple instance support is not enabled the
network name will default to the null string.
An octet string specified by an administrator that
must be in human-readable form. The names must conform
to the allowed characters that can be specified via
Command Line Interface(CLI). The names cannot contain
control character and should not contain leading or
trailing white space."
::= { cgspInstanceTableEntry 1 }
cgspInstNetworkIndicator OBJECT-TYPE
SYNTAX CItpTcNetworkIndicator
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Network Indicator for this Signalling point instance."
::= { cgspInstanceTableEntry 2 }
cgspInstVariant OBJECT-TYPE
SYNTAX CgspSS7Variant
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The SS7 variant used to format data used by this
instance."
::= { cgspInstanceTableEntry 3 }
cgspInstDisplayName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..30))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A short identifier for the Signalling point.
This value can be set by system administrator
or defaults to the local point code formatted
as an ASCII string."
::= { cgspInstanceTableEntry 4 }
cgspInstDescription OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..254))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual description for the Signalling point."
::= { cgspInstanceTableEntry 5 }
cgspInstTFR OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Allow transfer restricted messages.
'true' TFR are allowed.
'false' TFR are disabled."
DEFVAL { false }
::= { cgspInstanceTableEntry 6 }
cgspInstCongestionsLevels OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Allow multiple congestion levels.
'true' multiple congestion levels are allowed.
'false' multiple congestion levels are disabled."
DEFVAL { false }
::= { cgspInstanceTableEntry 7 }
cgspInstFastRestart OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The support for fast restarts as follows.
'true' fast restart is enabled.
'false' fast restart is disabled."
DEFVAL { false }
::= { cgspInstanceTableEntry 8 }
cgspInstDistSccpUnseq OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Evenly distribute Class 0 SCCP messages as follows.
'true' Evenly distribute 0 SCCP messages is enabled.
'false' Evenly distribute 0 SCCP messages is disabled."
DEFVAL { false }
::= { cgspInstanceTableEntry 9 }
cgspInstSummaryRoutingException OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to control the usage of the summary
route when both a summary route (or ANSI cluster route)
and a full point-code route (within that summary) are
configured. The object is used to indicate whether
the summary route is to be used when the full
point-code destination is inaccessible as follows.
'true' Use summary routing.
'false' Do not use summary routing."
DEFVAL { true }
::= { cgspInstanceTableEntry 10 }
cgspInstNumber OBJECT-TYPE
SYNTAX CItpTcInstanceNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique Identifier assigned to each instance."
::= { cgspInstanceTableEntry 11 }
cgspInstRouteTableName OBJECT-TYPE
SYNTAX CItpTcRouteTableName
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The routing table for Signalling network management
messages."
REFERENCE
"ITU Q.704 Signalling network functions and messages,
section 14.2.1."
::= { cgspInstanceTableEntry 12 }
cgspInstRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to
create or delete the row entry in cgspInstanceTable
following the RowStatus textual convention."
::= { cgspInstanceTableEntry 13 }
cgspInstSccpWrrOpcShift OBJECT-TYPE
SYNTAX Unsigned32 (0..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the shift amount for the
OPC bits in SCCP class1 WRR(Weighted round robin).
The range depends on the variant as follows.
The ITU range is 0-2
The ANSI range is 0-8
The CHINA range is 0-2
The JAPAN NTT range is 0-2
The JAPAN TTC range is 0-2"
::= { cgspInstanceTableEntry 14 }
cgspInstSccpWrrOption OBJECT-TYPE
SYNTAX CItpTcSccpWrrOption
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicate the options for calculate SCCP
class 1 traffic loadshare under WRR"
::= { cgspInstanceTableEntry 15 }
-- *************************************************************
-- * *
-- * Instance Timer Table *
-- * *
-- *************************************************************
cgspInstTimerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspInstTimerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the timer used to configure
an instances of signalling points. Entries are
added to this table via cgspInstTimerRowStatus in
accordance with the RowStatus convention."
::= { cgspInstance 2 }
cgspInstTimerTableEntry OBJECT-TYPE
SYNTAX CgspInstTimerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure all MTP3 timer
values that apply to linksets and links. The
values apply to all linkset and links defined to
this signalling point(instances)."
INDEX {
cgspInstNetwork,
cgspInstTimerNumber
}
::= { cgspInstTimerTable 1 }
CgspInstTimerTableEntry ::= SEQUENCE {
cgspInstTimerNumber CgspTimerNumbers,
cgspInstTimerValue CgspTimerValue,
cgspInstTimerRowStatus RowStatus
}
cgspInstTimerNumber OBJECT-TYPE
SYNTAX CgspTimerNumbers
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into table containing timer information."
::= { cgspInstTimerTableEntry 1 }
cgspInstTimerValue OBJECT-TYPE
SYNTAX CgspTimerValue
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of timer selected by cgspInstTimerNumber object."
::= { cgspInstTimerTableEntry 2 }
cgspInstTimerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to
create or delete the row entry in cgspInstTimerTable
following the RowStatus textual convention."
::= { cgspInstTimerTableEntry 3 }
-- *************************************************************
-- * *
-- * Instance UPU Table *
-- * *
-- *************************************************************
cgspInstUPUTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspInstUPUTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Instance UPU table contains information about the
number of UPU MSUs transmitted and received for the
specific user part(represented by service indicator)
and signalling point instance. The user part is
primarily represented with the possible service
indicator. This table provides the granularity of
information required by Q752 table 5.6 and 5.7."
::= { cgspInstance 3 }
cgspInstUPUTableEntry OBJECT-TYPE
SYNTAX CgspInstUPUTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each table entry represent the UPU MSU statistics
for a specific user part and signalling point
instance."
INDEX {
cgspInstNetwork,
cgspMtp3SI
}
::= { cgspInstUPUTable 1 }
CgspInstUPUTableEntry ::= SEQUENCE {
cgspMtp3SI CItpTcServiceIndicator,
cgspInstSIUPUReceived Counter32,
cgspInstSIUPUTransmitted Counter32,
cgspInstUserPartDisplay CgspDisplayInstanceUserPart
}
cgspMtp3SI OBJECT-TYPE
SYNTAX CItpTcServiceIndicator
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The service indicator."
::= { cgspInstUPUTableEntry 1 }
cgspInstSIUPUReceived OBJECT-TYPE
SYNTAX Counter32
UNITS "MSUs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of UPU MSUs that were received for the
associated user part(service indicator) and
and signalling point instance Q752/5.7."
REFERENCE
"ANSI GR-82-CORE 6.4.2 System Total Measurements Item 33
measurements received from remote Signalling point."
::= { cgspInstUPUTableEntry 2 }
cgspInstSIUPUTransmitted OBJECT-TYPE
SYNTAX Counter32
UNITS "MSUs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of UPU MSUs that were transmitted for the
associated user part(service indicator) and
and signalling point instance."
REFERENCE
"ANSI GR-82-CORE 6.4.2 System Total Measurements Item 33."
::= { cgspInstUPUTableEntry 3 }
cgspInstUserPartDisplay OBJECT-TYPE
SYNTAX CgspDisplayInstanceUserPart
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The associated instance name and user part information
formatted for display."
::= { cgspInstUPUTableEntry 4 }
-- *************************************************************
-- * *
-- * Point Code Table *
-- * *
-- *************************************************************
cgspPointCodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspPointCodeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains a list of point code defined for the
Signalling point defined by this instance. Entries are
added to this table via cgspPointCodeRowStatus in
accordance with the RowStatus convention."
::= { cgspPointCode 1 }
cgspPointCodeTableEntry OBJECT-TYPE
SYNTAX CgspPointCodeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Point codes for a signalling point
defined by an instance."
INDEX {
cgspInstNetwork,
cgspPointCodeNi,
cgspPointCodeBin
}
::= { cgspPointCodeTable 1 }
CgspPointCodeTableEntry ::= SEQUENCE {
cgspPointCodeNi CItpTcNetworkIndicator,
cgspPointCodeBin CItpTcPointCode,
cgspPointCodeType CItpTcPointCodeType,
cgspPointCodeDisplay CItpTcDisplayPC,
cgspPointCodeRowStatus RowStatus
}
cgspPointCodeNi OBJECT-TYPE
SYNTAX CItpTcNetworkIndicator
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network Indicator for this pointcode."
::= { cgspPointCodeTableEntry 1 }
cgspPointCodeBin OBJECT-TYPE
SYNTAX CItpTcPointCode
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The point code for this Signalling Point."
::= { cgspPointCodeTableEntry 2 }
cgspPointCodeType OBJECT-TYPE
SYNTAX CItpTcPointCodeType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The function of this point code."
::= { cgspPointCodeTableEntry 3 }
cgspPointCodeDisplay OBJECT-TYPE
SYNTAX CItpTcDisplayPC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The point code for this Signalling Point."
::= { cgspPointCodeTableEntry 4 }
cgspPointCodeRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to create or
delete the row entry in cgspPointCodeTable following
the RowStatus textual convention."
::= { cgspPointCodeTableEntry 5 }
-- *************************************************************
-- * *
-- * Linkset Table *
-- * *
-- *************************************************************
cgspLinksetTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspLinksetTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of linksets for this Signalling Point
defined by this instance."
::= { cgspLinkset 1 }
cgspLinksetTableEntry OBJECT-TYPE
SYNTAX CgspLinksetTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Signalling Point linkset attributes for
Signalling Point define by this instance."
INDEX {
cgspInstNetwork,
cgspLinksetName
}
::= { cgspLinksetTable 1 }
CgspLinksetTableEntry ::= SEQUENCE {
cgspLinksetName CItpTcLinksetId,
cgspLinksetSourcePointCode CItpTcPointCode,
cgspLinksetSourceDisplayPC CItpTcDisplayPC,
cgspLinksetAdjacentPointCode CItpTcPointCode,
cgspLinksetAdjacentDisplayPC CItpTcDisplayPC,
cgspLinksetState INTEGER,
cgspLinksetInboundAcl CItpTcAclId,
cgspLinksetOutboundAcl CItpTcAclId,
cgspLinksetAccountingMtp3 TruthValue,
cgspLinksetAccountingGtt TruthValue,
cgspLinksetNumLinks Unsigned32,
cgspLinksetDurationInService Counter32,
cgspLinksetDurationOutService Counter32,
cgspLinksetActPriority Unsigned32,
cgspLinksetDisplayName SnmpAdminString,
cgspLinksetDescription SnmpAdminString,
cgspLinksetRotateSlsEnable TruthValue,
cgspLinksetRotateSlsShift Unsigned32,
cgspLinksetProfileName CgspProfileName,
cgspLinksetAdjacentInst CItpTcNetworkName,
cgspLinksetRowStatus RowStatus
}
cgspLinksetName OBJECT-TYPE
SYNTAX CItpTcLinksetId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name of the linkset."
::= { cgspLinksetTableEntry 1 }
cgspLinksetSourcePointCode OBJECT-TYPE
SYNTAX CItpTcPointCode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The point code to which this linkset is connected."
::= { cgspLinksetTableEntry 2 }
cgspLinksetSourceDisplayPC OBJECT-TYPE
SYNTAX CItpTcDisplayPC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The point code to which this linkset is connected."
::= { cgspLinksetTableEntry 3 }
cgspLinksetAdjacentPointCode OBJECT-TYPE
SYNTAX CItpTcPointCode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The point code to which this linkset is connected."
::= { cgspLinksetTableEntry 4 }
cgspLinksetAdjacentDisplayPC OBJECT-TYPE
SYNTAX CItpTcDisplayPC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The point code to which this linkset is connected."
::= { cgspLinksetTableEntry 5 }
cgspLinksetState OBJECT-TYPE
SYNTAX INTEGER {
available(1),
shutdown(2),
unavailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The list of possible linkset states.
'available' : Traffic may flow over this linkset
'shutdown' : This linkset has been forced to an
unavailable state by an administrative
action.
'unavailable': The linkset is currently unable to support
traffic. Activation of this linkset will
occur as required by protocol."
::= { cgspLinksetTableEntry 6 }
cgspLinksetInboundAcl OBJECT-TYPE
SYNTAX CItpTcAclId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Packets are filtered against this access control list
before they are passed to the routing function. A
value of zero indicates that no access control list
is present."
::= { cgspLinksetTableEntry 7 }
cgspLinksetOutboundAcl OBJECT-TYPE
SYNTAX CItpTcAclId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Packets are filtered against this access control list
after they have passed through the routing function.
A value of zero indicates that no access control list
is present."
::= { cgspLinksetTableEntry 8 }
cgspLinksetAccountingMtp3 OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This indicates if accounting for this linkset is
enabled.
'true' Indicates that the accounting function is
enabled for this linkset and is being
accumulated in cgactMtp3Table.
'false' Indicates that the accounting function is
disabled."
DEFVAL { false }
::= { cgspLinksetTableEntry 9 }
cgspLinksetAccountingGtt OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This indicates if accounting for this linkset is
enabled.
'true' Indicates that the accounting function is
enabled for this linkset and is being
accumulated in cgactMtp3Table.
'false' Indicates that the accounting function is
disabled."
DEFVAL { false }
::= { cgspLinksetTableEntry 10 }
cgspLinksetNumLinks OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of links in this linkset."
::= { cgspLinksetTableEntry 11 }
cgspLinksetDurationInService OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time linkset was providing service related to
Q752/Table 4.2."
::= { cgspLinksetTableEntry 12 }
cgspLinksetDurationOutService OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time linkset was Out-of-Service as required for
Q752/Table 4.2."
::= { cgspLinksetTableEntry 13 }
cgspLinksetActPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines the activation priority for linksets. The
linksets with the lowest values will be activated
first. If two or more linksets share the same values
they will be activated in the order they were defined."
DEFVAL { 0 }
::= { cgspLinksetTableEntry 14 }
cgspLinksetDisplayName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..30))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A short identifier for each linkset.
This value can be set by system administrator
or defaults to the linkset name."
::= { cgspLinksetTableEntry 15 }
cgspLinksetDescription OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..254))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual description for the Signalling point."
::= { cgspLinksetTableEntry 16 }
cgspLinksetRotateSlsEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This defines whether signalling link selector(SLS) will
be rotated. This option only applies to ANSI variant
and will return false for all other variants. By default
SLS rotation is enable by default for ANSI linksets. ANSI
specifications state that SLS rotation should not be
performed on C type linksets. This object can be used to
disable SLS rotation.
'true' Indicates that SLS rotation is enable for this
linkset.
'false' Indicates that SLS rotation is disable for this
linkset."
::= { cgspLinksetTableEntry 17 }
cgspLinksetRotateSlsShift OBJECT-TYPE
SYNTAX Unsigned32 (0..3)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value used to shift the signalling link selector(SLS)
when rotation is enabled. This option only applies to
ANSI variant and will return 0 all other variants."
::= { cgspLinksetTableEntry 18 }
cgspLinksetProfileName OBJECT-TYPE
SYNTAX CgspProfileName
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When specified this object indicates which profile will be
used to establish defaults for common configuration
values like MTP2 and MTP3 timers. The null string is used
to indicate that the linkset does not have a profile."
::= { cgspLinksetTableEntry 19 }
cgspLinksetAdjacentInst OBJECT-TYPE
SYNTAX CItpTcNetworkName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When a linkset is used to carry traffic between
different instances, this object contains the
network name used as an index into the cgspInstanceTable
table. In all other cases the object will contain
the same network name as the source signalling point."
::= { cgspLinksetTableEntry 20 }
cgspLinksetRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to
create or delete the row entry in cgspLinksetTable
following the RowStatus textual convention."
::= { cgspLinksetTableEntry 21 }
-- *************************************************************
-- * *
-- * Linkset Timer Table *
-- * *
-- *************************************************************
cgspLinksetTimerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspLinksetTimerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the timer used to configure timer
values specific to a particular linkset. Entries are added
to this table via cgspLinksetTimerRowStatus in accordance
with the RowStatus convention."
::= { cgspLinkset 2 }
cgspLinksetTimerTableEntry OBJECT-TYPE
SYNTAX CgspLinksetTimerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure all MTP3 timer
values that apply to linksets and links. The
values apply to this linkset and links it c
contains."
INDEX {
cgspInstNetwork,
cgspLinksetName,
cgspLinksetTimerNumber
}
::= { cgspLinksetTimerTable 1 }
CgspLinksetTimerTableEntry ::= SEQUENCE {
cgspLinksetTimerNumber CgspTimerNumbers,
cgspLinksetTimerValue CgspTimerValue,
cgspLinksetTimerRowStatus RowStatus
}
cgspLinksetTimerNumber OBJECT-TYPE
SYNTAX CgspTimerNumbers
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into table containing timer information."
::= { cgspLinksetTimerTableEntry 1 }
cgspLinksetTimerValue OBJECT-TYPE
SYNTAX CgspTimerValue
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of timer selected by cgspLinksetTimerNumber object."
::= { cgspLinksetTimerTableEntry 2 }
cgspLinksetTimerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to
create or delete the row entry in cgspLinksetTimerTable
following the RowStatus textual convention."
::= { cgspLinksetTimerTableEntry 3 }
-- *************************************************************
-- * *
-- * GSP - Link Table *
-- * *
-- *************************************************************
cgspLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspLinkTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of links for each Signalling Point."
::= { cgspLink 1 }
cgspLinkTableEntry OBJECT-TYPE
SYNTAX CgspLinkTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of signalling point link attributes."
INDEX {
cgspInstNetwork,
cgspLinksetName,
cgspLinkSlc
}
::= { cgspLinkTable 1 }
CgspLinkTableEntry ::= SEQUENCE {
cgspLinkSlc CItpTcLinkSLC,
cgspLinkDescription SnmpAdminString,
cgspLinkState INTEGER,
cgspLinkReason INTEGER,
cgspLinkType CItpTcLinkType,
cgspLinkifIndex InterfaceIndexOrZero,
cgspLinkSctpAssociation Unsigned32,
cgspLinkXmitQueueDepth Gauge32,
cgspLinkXmitQueueDepthHigh Unsigned32,
cgspLinkXmitQueueDepthHighRT TimeStamp,
cgspLinkCongestionState Unsigned32,
cgspLinkCongestionAbate1 Unsigned32,
cgspLinkCongestionAbate2 Unsigned32,
cgspLinkCongestionAbate3 Unsigned32,
cgspLinkCongestionOnset1 Unsigned32,
cgspLinkCongestionOnset2 Unsigned32,
cgspLinkCongestionOnset3 Unsigned32,
cgspLinkSigLinkTest TruthValue,
cgspLinkQ752T1E1 Counter32,
cgspLinkQ752T1E2 Counter32,
cgspLinkQ752T1E3 Counter32,
cgspLinkQ752T1E5 Counter32,
cgspLinkQ752T1E7 Counter32,
cgspLinkQ752T1E8 Counter32,
cgspLinkQ752T1E9 Counter32,
cgspLinkQ752T1E10 Counter32,
cgspLinkQ752T1E11 Counter32,
cgspLinkQ752T2E1 Counter32,
cgspLinkQ752T2E5 Counter32,
cgspLinkQ752T2E6 Counter32,
cgspLinkQ752T2E7 Counter32,
cgspLinkQ752T2E9 Counter32,
cgspLinkQ752T2E10 Counter32,
cgspLinkQ752T2E15 Counter32,
cgspLinkQ752T2E16 Counter32,
cgspLinkQ752T2E18 Counter32,
cgspLinkQ752T3E1 Counter32,
cgspLinkQ752T3E2Bytes Counter32,
cgspLinkQ752T3E2Packets Counter32,
cgspLinkQ752T3E3 Counter32,
cgspLinkQ752T3E4 Counter32,
cgspLinkQ752T3E5 Counter32,
cgspLinkQ752T3E6 Counter32,
cgspLinkQ752T3E7 Counter32,
cgspLinkQ752T3E10L1 Counter32,
cgspLinkQ752T3E10L2 Counter32,
cgspLinkQ752T3E10L3 Counter32,
cgspLinkQ752T3E11L1 Counter32,
cgspLinkQ752T3E11L2 Counter32,
cgspLinkQ752T3E11L3 Counter32,
cgspLinkLocalPeerPort InetPortNumber,
cgspLinkRemotePeerPort InetPortNumber,
cgspLinkQosClass CItpTcQos,
cgspLinkDisplayName SnmpAdminString,
cgspLinkDroppedPkts Counter32,
cgspLinkTransmittedLSSUs Counter32,
cgspLinkReceivedLSSUs Counter32,
cgspLinkProtocolDetails BITS,
cgspLinkLsacState INTEGER,
cgspLinkTsrcState INTEGER,
cgspLinkTcocState INTEGER,
cgspLinkTcocLocalBSNT CgspSequenceNumber,
cgspLinkTcocRemoteBSNT CgspSequenceNumber,
cgspLinkTcbcState INTEGER,
cgspLinkReceivedSIBs Counter32,
cgspLinkTransmittedSIBs Counter32,
cgspLinkMtp2T01Counts Counter32,
cgspLinkMtp2T02Counts Counter32,
cgspLinkMtp2T03Counts Counter32,
cgspLinkMtp2T04Counts Counter32,
cgspLinkMtp2T05Counts Counter32,
cgspLinkMtp2T06Counts Counter32,
cgspLinkMtp2T07Counts Counter32,
cgspLinkOMAERMCounts Counter32,
cgspLinkOMAERMFailCounts Counter32,
cgspLinkOMSURMCounts Counter32,
cgspLinkOMSURMFailCounts Counter32,
cgspLinkPlanCapacityRcvd CgspLinkCapacity,
cgspLinkUtilThresholdRcvd CgspPercentThreshold,
cgspLinkUtilizationRcvd CgspLinkUtilization,
cgspLinkUtilStateRcvd CgspLinkUtilizationState,
cgspLinkL2BytesRcvd Counter32,
cgspLinkPlanCapacitySent CgspLinkCapacity,
cgspLinkUtilThresholdSent CgspPercentThreshold,
cgspLinkUtilizationSent CgspLinkUtilization,
cgspLinkUtilStateSent CgspLinkUtilizationState,
cgspLinkL2BytesSent Counter32,
cgspLinkTestResult CgspLinkTestResults,
cgspLinkRowStatus RowStatus,
cgspLinkSctpAssociationId Unsigned32,
cgspLinkQ752T1E12 Counter32,
cgspLinkQ752T1E12Errors Counter32,
cgspLinkQ752T2E11 Counter32,
cgspLinkQ752T2E17 Counter32,
cgspLinkQ752T2E19 Counter32,
cgspLinkRxCongestionState Unsigned32
}
cgspLinkSlc OBJECT-TYPE
SYNTAX CItpTcLinkSLC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Signalling Link Code for this link."
REFERENCE
"ITU Q.704 Signalling network functions and messages.
ANSI T1.111 Telecommunications - Signalling system
No. 7 (SS7)-Message Transfer Part (MTP)."
::= { cgspLinkTableEntry 1 }
cgspLinkDescription OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..254))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual description for this link."
::= { cgspLinkTableEntry 2 }
cgspLinkState OBJECT-TYPE
SYNTAX INTEGER {
available(1),
failed(2),
shutdown(3),
unavailable(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The list of possible links states.
'available' : Traffic may flow over this linkset
'failed' : Traffic management has detected a failure
that prevents activating this linkset.
'shutdown' : This linkset has been forced to an
unavailable state by an administrative
action.
'unavailable': The linkset is currently unable to support
traffic. Activation of this linkset will
occur as required by protocol."
::= { cgspLinkTableEntry 3 }
cgspLinkReason OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
changeOverInProgress(1),
mgmtDisconnectRequest(2),
linkAlignmentLost(3),
connectionLost(4),
localDisconnect(5),
remoteDisconnect(6),
suermFailure(7),
t1Timeout(8),
t2Timeout(9),
t3Timeout(10),
t6Timeout(11),
t7Timeout(12),
provingFailure(13),
protocolErrorBsn(14),
protocolErrorFib(15),
protocolErrorSin(16),
protocolErrorLssu(17),
peerNotReady(18),
communicationLost(19),
noListenPosted(20),
bufferNotAvailable(21),
cardRemoved(22),
cardInserted(23),
falseLinkCongestion(24),
configDownload(25),
localInhibit(26),
localUninhibit(27),
remoteInhibit(28),
remoteUninhibit(29),
localBlocked(30),
localUnBlocked(31),
remoteBlocked(32),
remoteUnblocked(33),
linkRestored(34),
linkTestFailure(35)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides additional information on the source
of a link failure. This object will contain the last reason
that caused the link to fail.
'unknown' : Link has failed do to an undetermined cause.
'changeOverInProgress' : Change over in progress.
'mgmtDisconnectRequest' : Management disconnect
request.
'linkAlignmentLost' : Link alignment lost.
'connectionLost' : Link connection lost.
'localDisconnect' : Local Disconnect.
'remoteDisconnect' : Remote Disconnect.
'suermFailure' : Signal unit error rate monitor
failure.
't1Timeout' : T1 timeout no FISU received.
't2Timeout' : T2 timeout no SIO received.
't3Timeout' : T3 timeout no SIN received.
't6Timeout' : T6 timeout excessive congestion.
't7Timeout' : T7 timeout excessive acknowledgement
delay.
'provingFailure' : Link proving failure.
'protocolError-BSN' : Abnormal BSN received.
'protocolError-FIB' : Abnormal FIB received.
'protocolError-SIN' : Abnormal SIB received.
'protocolError-LSSU' : Abnormal LSSU received.
'peerNotReady' : Peer not ready.
'communicationLost' : Communication lost.
'noListenPosted' : No Listen posted.
'bufferNotAvailable' : Unable to allocate buffer.
'cardRemoved' : Link card removed.
'cardInserted' : Link card Inserted.
'falseLinkCongestion' : false link congestion.
'configDownload' : Configuration downloading.
'localInhibit' : Local request to inhibit link.
'localUninhibit' : Local request to uninhibit link.
'remoteInhibit' : Remote request to inhibit link.
'remoteUninhibit': Local request to uninhibit link.
'localBlocked' : Local Processor outage.
'localUnBlocked' : Local Processor recovery.
'remoteBlocked' : Remote Processor outage.
'remoteUnblocked': Remote Processor recovery.
'linkRestored' : Link restored.
'linkTestFailure': Signalling Link Test failure.'"
::= { cgspLinkTableEntry 4 }
cgspLinkType OBJECT-TYPE
SYNTAX CItpTcLinkType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The link type."
REFERENCE "For SCTP see RFC 2960."
::= { cgspLinkTableEntry 5 }
cgspLinkifIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If the link type specified by cgspLinkType is serial
or high speed Link, this is the ifIndex specified in
IF-MIB, otherwise no significance is to be placed on
this value."
REFERENCE "RFC1213.txt"
::= { cgspLinkTableEntry 6 }
cgspLinkSctpAssociation OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Association Identifiers can be greater than 65,535.
This object has been replaced by
cgspLinkSctpAssociationId."
::= { cgspLinkTableEntry 7 }
cgspLinkXmitQueueDepth OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets waiting to be sent over this link."
::= { cgspLinkTableEntry 8 }
cgspLinkXmitQueueDepthHigh OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the maximum number of packets waiting
to be sent over this link since the last time this
value was reset as indicated by
cgspLinkXmitQueueDepthHighRT.
Resetting this object is achieved by setting this
object to 0. Attempting to set this object to any
other value will result in a wrongValue (SNMPv2c,
SNMPv3) or badValue (SNMPv1)."
::= { cgspLinkTableEntry 9 }
cgspLinkXmitQueueDepthHighRT OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates when cgspLinkXmitQueueDepthHigh
was last set to 0."
::= { cgspLinkTableEntry 10 }
cgspLinkCongestionState OBJECT-TYPE
SYNTAX Unsigned32 (0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Signalling link congestion status of this link. 0
is the least congestion level, 3 is the highest
congestion level."
REFERENCE
"ITU Q.704 Signalling network functions and messages.
ANSI T1.111 Telecommunications - Signalling system
No. 7 (SS7)-Signalling network functions and messages
2.3.5.2."
::= { cgspLinkTableEntry 11 }
cgspLinkCongestionAbate1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold used to abate congestion level 1."
::= { cgspLinkTableEntry 12 }
cgspLinkCongestionAbate2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold used to abate congestion level 2."
::= { cgspLinkTableEntry 13 }
cgspLinkCongestionAbate3 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold used to abate congestion level 3."
::= { cgspLinkTableEntry 14 }
cgspLinkCongestionOnset1 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold used to mark onset of congestion level 1."
::= { cgspLinkTableEntry 15 }
cgspLinkCongestionOnset2 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold used to mark onset of congestion level 2."
::= { cgspLinkTableEntry 16 }
cgspLinkCongestionOnset3 OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold used to mark onset of congestion level 3."
::= { cgspLinkTableEntry 17 }
cgspLinkSigLinkTest OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicated if Signalling link test is enabled on this
link.
true : Signalling link test is enabled.
false : Signalling link test not enabled."
DEFVAL { true }
::= { cgspLinkTableEntry 18 }
cgspLinkQ752T1E1 OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration of link in the In-Service state Q752/1.1."
REFERENCE
"ANSI GR-82-CORE 6.4.4 Link Measurements Item 23-24."
::= { cgspLinkTableEntry 19 }
cgspLinkQ752T1E2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Signalling Link failures - All reasons Q752/1.2."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 29."
::= { cgspLinkTableEntry 20 }
cgspLinkQ752T1E3 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Signalling Link failures - Abnormal FIBR/BSNR
Q752/1.3"
::= { cgspLinkTableEntry 21 }
cgspLinkQ752T1E5 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Signalling Link failures - Excessive error rate
Q752/1.5."
::= { cgspLinkTableEntry 22 }
cgspLinkQ752T1E7 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of alignment or proving errors Q752/1.7."
::= { cgspLinkTableEntry 23 }
cgspLinkQ752T1E8 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of signal units received in error Q752/1.8."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 33."
::= { cgspLinkTableEntry 24 }
cgspLinkQ752T1E9 OBJECT-TYPE
SYNTAX Counter32
UNITS "negative acknowledgements"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of negative acknowledgements received Q752/1.9."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 34."
::= { cgspLinkTableEntry 25 }
cgspLinkQ752T1E10 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of 'local automatic changeover' events
Q752/1.10."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 25."
::= { cgspLinkTableEntry 26 }
cgspLinkQ752T1E11 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of 'local automatic changeback' events Q752/1.11."
::= { cgspLinkTableEntry 27 }
-- Q752.12 Signalling Link Restoration The standard only requires
-- that an event be issued when this occurs.
cgspLinkQ752T2E1 OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration of Signalling Link unavailable(for any reason)
Q752/2.1."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 30."
::= { cgspLinkTableEntry 28 }
-- Q752/2.2 - Q752/2.4 deleted
cgspLinkQ752T2E5 OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration of Signalling Link unavailable due to local
management actions Q752/2.5."
::= { cgspLinkTableEntry 29 }
cgspLinkQ752T2E6 OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration of Signalling Link unavailable due to remote
management actions Q752/2.6."
::= { cgspLinkTableEntry 30 }
cgspLinkQ752T2E7 OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration of Signalling Link unavailable due to link
failure Q752/2.7."
::= { cgspLinkTableEntry 31 }
cgspLinkQ752T2E9 OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration of Signalling Link unavailable due to remote
processor outage Q752/2.9."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 31."
::= { cgspLinkTableEntry 32 }
cgspLinkQ752T2E10 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of 'remote processor outage' events Q752/2.10 and
Q752/2.11. The standard only requires that events are
issued. The entries have been combined into a single
entry to track all occurrences of these event types."
::= { cgspLinkTableEntry 33 }
cgspLinkQ752T2E15 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Status Indicator Busy received Q752/2.15."
::= { cgspLinkTableEntry 34 }
cgspLinkQ752T2E16 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of local inhibition Q752/2.16 and Q752/2.17.
The standard only requires that events are issued.
The entries have been combined into a single
entry to track all occurrences of these event types."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 27."
::= { cgspLinkTableEntry 35 }
cgspLinkQ752T2E18 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of remote inhibition Q752/2.18 and Q752/2.19.
The standard only requires that events are issued.
The entries have been combined into a single
entry to track all occurrences of these event types."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 28."
::= { cgspLinkTableEntry 36 }
cgspLinkQ752T3E1 OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MTP3 bytes sent by this link.
This measurement is specified in Q752/3.1"
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 4."
::= { cgspLinkTableEntry 37 }
cgspLinkQ752T3E2Bytes OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MTP3 bytes retransmitted on this link.
This measurement is specified in Q752/3.2"
::= { cgspLinkTableEntry 38 }
cgspLinkQ752T3E2Packets OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MTP3 packets retransmitted on this link.
This measurement is specified in Q752/3.2"
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 3."
::= { cgspLinkTableEntry 39 }
cgspLinkQ752T3E3 OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MTP3 packets sent by this link.
This measurement is specified in Q752/3.3."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 1."
::= { cgspLinkTableEntry 40 }
cgspLinkQ752T3E4 OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MTP3 bytes received by this link.
This measurement is specified in Q752/3.4"
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 5."
::= { cgspLinkTableEntry 41 }
cgspLinkQ752T3E5 OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MTP3 packets received by this link.
This measurement is specified in Q752/3.5"
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 1."
::= { cgspLinkTableEntry 42 }
cgspLinkQ752T3E6 OBJECT-TYPE
SYNTAX Counter32
UNITS "events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number times this Signalling link was marked
congested. This measurement is specified in Q752/3.6"
::= { cgspLinkTableEntry 43 }
cgspLinkQ752T3E7 OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cumulative duration of Signalling link congestion
Q752/3.7."
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 11."
::= { cgspLinkTableEntry 44 }
cgspLinkQ752T3E10L1 OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets(MSUs) discarded due to Signalling
link level 1 congestion Q752/3.10"
REFERENCE
"ANSI GR-82-CORE 6.4.4 Link Measurements Item 17-19."
::= { cgspLinkTableEntry 45 }
cgspLinkQ752T3E10L2 OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets(MSUs) discard due to Signalling
link level 2 congestion Q752/3.10"
REFERENCE
"ANSI GR-82-CORE 6.4.4 Link Measurements Item 18-19."
::= { cgspLinkTableEntry 46 }
cgspLinkQ752T3E10L3 OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets(MSUs) discard due to Signalling
link level 3 congestion Q752/3.10"
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 19."
::= { cgspLinkTableEntry 47 }
cgspLinkQ752T3E11L1 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number times this Signalling link entered congestion
level 1 and packets were discarded. This measurement is
specified in Q752/3.11"
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 14."
::= { cgspLinkTableEntry 48 }
cgspLinkQ752T3E11L2 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number times this Signalling link entered congestion
level 2 and packets were discarded. This measurement is
specified in Q752/3.11"
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 15."
::= { cgspLinkTableEntry 49 }
cgspLinkQ752T3E11L3 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number times this Signalling link entered congestion
level 3 and packets were discarded. This measurement is
specified in Q752/3.11"
REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 16."
::= { cgspLinkTableEntry 50 }
cgspLinkLocalPeerPort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When cgspLinkType is set to 'sctpIp' then this object
contains the local port number used to create the
association supporting this link. This object can
be used to obtain information from the cgsp2LocalPeerTable
and cgsp2LpIpAddrTable Tables in the CISCO-ITP-GSP2-MIB.my
MIB."
::= { cgspLinkTableEntry 51 }
cgspLinkRemotePeerPort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When cgspLinkType is set to 'sctpIp' then this object
contains the remote port number used to create the
association supporting this link.
When cgspLinkType is not set to 'sctpIp' then no
significance is to be placed on this value."
::= { cgspLinkTableEntry 52 }
cgspLinkQosClass OBJECT-TYPE
SYNTAX CItpTcQos
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When cgspLinkType is set to 'sctpIp' then this object
contains the quality of service class to be assigned
to packets sent on this association.
When cgspLinkType is not set to 'sctpIp' then no
significance is to be placed on this value."
::= { cgspLinkTableEntry 53 }
cgspLinkDisplayName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..30))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A short identifier for each link linkset.
This value can be set by system administrator
or defaults to the linkset name and SLC
formatted as an ASCII string."
::= { cgspLinkTableEntry 54 }
cgspLinkDroppedPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets that were dropped by this link."
::= { cgspLinkTableEntry 55 }
cgspLinkTransmittedLSSUs OBJECT-TYPE
SYNTAX Counter32
UNITS "LSSU"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Link Status Signal Units sent on this
link."
::= { cgspLinkTableEntry 56 }
cgspLinkReceivedLSSUs OBJECT-TYPE
SYNTAX Counter32
UNITS "LSSU"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Link Status Signal Units received on this
link."
::= { cgspLinkTableEntry 57 }
cgspLinkProtocolDetails OBJECT-TYPE
SYNTAX BITS {
tcbcBuffering(0),
tcocBuffering(1),
tlacAdjacentSpRestarting(2),
tlacEmergencyCoInProgress(3),
tlacChangebackInProgress(4),
tlacChangeoverInProgress(5),
tlacChangeoverFailed(6),
tlacInhibitRetry(7),
tlacManagementRequest(8),
tlacSpRestarting(9),
tsrcChangeOverComplete(10),
tsrcAdjacentSpRestart(11),
tlacLocalInhibit(12),
tlacRemoteInhibit(13),
tlacLocalBlocked(14),
tlacRemoteBlocked(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provide details on the protocol states
for this link as follows.
Changeback control(TCBC)
'tcbcBuffering': Changeback control is buffering data
on this link.
Changeover control(TCOC)
'tcocBuffering': Changeover control is buffering data
on this link
Link availability control(TLAC)
'tlacAdjacentSpRestarting': Adjacent Signalling point
is restarting.
'tlacEmergencyCoInProgress': Emergency changeover is in
progress on this link.
'tlacChangebackInProgress': Changeback is in progress
on this link.
'tlacChangeoverInProgress': Changeover is in progress
on this link.
'tlacChangeoverFailed': The last changeover operation
failed on this link.
'tlacInhibitRetry': Inhibit command will be retried.
'tlacManagementRequest': Management request in progress
for this link.
'tlacSpRestarting': Signalling point is in the process
of a restart.
'tlacLocalInhibit': Link has been inhibited by a
local management operation.
'tlacRemoteInhibit': Link has been inhibited by a
remote management operation.
'tlacLocalBlocked': Link is blocked because of a
local processor outage.
'tlacRemoteBlocked': Link is blocked because of a
remote processor outage.
Signalling routing control(TSRC)
'tsrcChangeOverComplete': Changeove request is complete.
'tsrcAdjacentSpRestart': Adjacent Signalling Point is
restarting."
::= { cgspLinkTableEntry 58 }
cgspLinkLsacState OBJECT-TYPE
SYNTAX INTEGER {
undefined(1),
inactive(2),
active(3),
activatingRestoring(4),
failed(5),
actT17wait(6),
actAnsiWaitDeloaded(7),
actItuWaitStmReady(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signalling link activity control state:
'undefined' - link is an undefined state
'inactive' - A Signalling link that is not in
operation.
'active' - A Signalling link that is in
operation.
'activatingRestoring' - A Signalling that is not operational
and is being activated or restored.
'failed' - A Signalling link which is available
(not blocked) is marked by level 3 as
failed when a changeover order is
received.
'actT17wait' - Link activation has failed. Link is
placed into this state to wait for timer
T17 to expire in order to avoid the
oscillation of initial alignment failure
and link restart.
'actAnsiWaitDeloaded - Waiting for change back
acknowledgement (second attempt).
'actItuWaitStmReady' Wait for Signalling Traffic
Management ready event."
REFERENCE
"Figure 37/Q.704 - Signalling link management.
Signalling link activity control (LSAC)"
::= { cgspLinkTableEntry 59 }
cgspLinkTsrcState OBJECT-TYPE
SYNTAX INTEGER {
undefined(1),
idle(2),
wait5(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signalling traffic management routing control state:
'undefined' - link is an undefined state
'idle' - traffic management is idle
'wait5' - traffic management is active and
in the sending status phase"
REFERENCE
"Figure 29/Q.704 - Signalling traffic management;
Signalling routing control (TSRC)"
::= { cgspLinkTableEntry 60 }
cgspLinkTcocState OBJECT-TYPE
SYNTAX INTEGER {
undefined(1),
idle(2),
wait2(3),
waitForAck(4),
retrieving(5),
wait5(6),
wait7(7),
wait8(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Changeover control State:
'undefined' - Link is an undefined state.
'idle' - Link is available and idle.
'wait2' - Wait for MTP2 to initialize link.
'waitForAck' - Waiting for changeover
acknowledgement.
'retrieving' - Packets are being retrieved from
link.
'wait5' - Wait state when transitioning from
idle state.
'wait7' - Delay to avoid message mis-sequencing
on changeover
'wait8' - Wait state prior to processing
changeover order or emergency
changeover order events."
REFERENCE
"Figure 30/Q.704 - Signalling traffic management;
changeover control (TCOC)"
::= { cgspLinkTableEntry 61 }
cgspLinkTcocLocalBSNT OBJECT-TYPE
SYNTAX CgspSequenceNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local backward sequence number to be transmitted."
::= { cgspLinkTableEntry 62 }
cgspLinkTcocRemoteBSNT OBJECT-TYPE
SYNTAX CgspSequenceNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote backward sequence number to be transmitted."
::= { cgspLinkTableEntry 63 }
cgspLinkTcbcState OBJECT-TYPE
SYNTAX INTEGER {
undefined(1),
idle(2),
firstAttempt(3),
secondAttempt(4),
timeControlledDiversion(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Changeback control State:
'undefined' - link is an undefined state.
'idle' - Link is available and idle.
'firstAttempt' - First attempt at changeback.
'secondAttempt' - Second attempt at changeback
'timeControlledDiversion' - Changeback using
time controlled Diversion."
::= { cgspLinkTableEntry 64 }
cgspLinkReceivedSIBs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of status indicator 'busy' link status signal
units received on this link. The SIB indicates that
level two is congested at the transmitting Signalling
point."
::= { cgspLinkTableEntry 65 }
cgspLinkTransmittedSIBs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of status indicator 'busy' link status signal
units transmitted on this link. The SIB indicates that
level two is congested at the transmitting Signalling
point."
::= { cgspLinkTableEntry 66 }
cgspLinkMtp2T01Counts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the alignment ready timer has
expired on this link."
::= { cgspLinkTableEntry 67 }
cgspLinkMtp2T02Counts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the not alignment ready timer has
expired on this link."
::= { cgspLinkTableEntry 68 }
cgspLinkMtp2T03Counts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the aligned timer has
expired on this link."
::= { cgspLinkTableEntry 69 }
cgspLinkMtp2T04Counts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the proving period timer
has expired on this link."
::= { cgspLinkTableEntry 70 }
cgspLinkMtp2T05Counts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the sending status indicator
busy timer has expired on this link."
::= { cgspLinkTableEntry 71 }
cgspLinkMtp2T06Counts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the remote congestion
timer has expired on this link(Q752/1.6)."
::= { cgspLinkTableEntry 72 }
cgspLinkMtp2T07Counts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the excessive delay of
acknowledgement timer has expired on
this link(Q752/1.4)."
::= { cgspLinkTableEntry 73 }
cgspLinkOMAERMCounts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the Alignment Error Rate Monitor
procedure was started on this link."
::= { cgspLinkTableEntry 74 }
cgspLinkOMAERMFailCounts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the Alignment Error Rate Monitor
procedure failed on this link."
::= { cgspLinkTableEntry 75 }
cgspLinkOMSURMCounts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the Signal Unit Error Rate Monitor
procedure was started on this link."
::= { cgspLinkTableEntry 76 }
cgspLinkOMSURMFailCounts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the Signal Unit Error Rate Monitor
procedure failed on this link."
::= { cgspLinkTableEntry 77 }
cgspLinkPlanCapacityRcvd OBJECT-TYPE
SYNTAX CgspLinkCapacity
UNITS "bits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An estimate of the number of bits per second that is
expected to be received from this link. This
object will be used in combination with
cgspUtilSampleInterval, cgspUtilThreshold,
cgspUtilThreshold and cgspLinkUtilThresholdRcvd
to generate the ciscoGspLinkRcvdUtilChange notification."
::= { cgspLinkTableEntry 78 }
cgspLinkUtilThresholdRcvd OBJECT-TYPE
SYNTAX CgspPercentThreshold
UNITS "percent"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the threshold used to
to generate the ciscoGspLinkRcvdUtilChange notification.
The value of zero indicates the threshold has not been
defined at the link level and the value from the
cgspLinksetUtilThresholdRcvd or cgspUtilThreshold
objects will be used to generate the
ciscoGspLinkRcvdUtilChange notification."
DEFVAL { 0 }
::= { cgspLinkTableEntry 79 }
cgspLinkUtilizationRcvd OBJECT-TYPE
SYNTAX CgspLinkUtilization
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the utilization of this link for traffic
received on this link in the prior time period defined
by the cgspUtilSampleInterval object."
::= { cgspLinkTableEntry 80 }
cgspLinkUtilStateRcvd OBJECT-TYPE
SYNTAX CgspLinkUtilizationState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link Utilization State for inbound traffic."
::= { cgspLinkTableEntry 81 }
cgspLinkL2BytesRcvd OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the bytes received on the link including the
additional bytes required by underlying protocols.
This provides a transport independent mechanism
for collection information on link utilization."
::= { cgspLinkTableEntry 82 }
cgspLinkPlanCapacitySent OBJECT-TYPE
SYNTAX CgspLinkCapacity
UNITS "bits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An estimate of the number of bits per second that is
expected to be sent on this link. This object will
be used in combination with cgspUtilSampleInterval,
cgspUtilThreshold and cgspLinkUtilThresholdRcvd to
generate the ciscoGspLinkSentUtilChange notification."
::= { cgspLinkTableEntry 83 }
cgspLinkUtilThresholdSent OBJECT-TYPE
SYNTAX CgspPercentThreshold
UNITS "percent"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the threshold used to generate the
ciscoGspLinkRcvdUtilChange notification. The value of zero
indicates the threshold has not been defined at the link
level and the value from the cgspLinksetUtilThresholdRcvd
or cgspUtilThreshold objects will be used to generate the
ciscoGspLinkRcvdUtilChange notification."
DEFVAL { 0 }
::= { cgspLinkTableEntry 84 }
cgspLinkUtilizationSent OBJECT-TYPE
SYNTAX CgspLinkUtilization
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the utilization of this link for traffic
sent on this link in the prior time period defined
by the cgspUtilSampleInterval object."
::= { cgspLinkTableEntry 85 }
cgspLinkUtilStateSent OBJECT-TYPE
SYNTAX CgspLinkUtilizationState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link Utilization State for out bound traffic."
::= { cgspLinkTableEntry 86 }
cgspLinkL2BytesSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the bytes sent on the link including the
additional bytes required by underlying protocols.
This provides a transport independent mechanism
for collection information on link utilization."
::= { cgspLinkTableEntry 87 }
cgspLinkTestResult OBJECT-TYPE
SYNTAX CgspLinkTestResults
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides information on result from
signalling link test received on this link."
::= { cgspLinkTableEntry 88 }
cgspLinkRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to
create or delete the row entry in cgspLinkTable
following the RowStatus textual convention."
::= { cgspLinkTableEntry 89 }
cgspLinkSctpAssociationId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the link type specified by cgspLinkType is 'sctpIp',
this is the association identifier defined in the
Stream Control Transmission Protocol(SCTP) MIB. Where
value greater than zero indicates a valid association.
The zero value indicates an association does not exist
for this link. This value will always be set to
zero one when cgspLinkType is not equal to the
'sctpIp' value. This object replaces
cgspLinkSctpAssociation and allows association
identifiers to be larger than 65,535."
::= { cgspLinkTableEntry 90 }
cgspLinkQ752T1E12 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of 'Signalling Link Restoration' events Q752/1.12."
::= { cgspLinkTableEntry 91 }
cgspLinkQ752T1E12Errors OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of 'Signalling Link Restoration' error events related
to Q752/1.12. i.e., the number of times the link restoration
was attempted and the link was not recovered."
::= { cgspLinkTableEntry 92 }
cgspLinkQ752T2E11 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of 'remote processor recovery' events Q752/2.11.
The standard only requires that events are issued."
::= { cgspLinkTableEntry 93 }
cgspLinkQ752T2E17 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of local uninhibition Q752/2.17. The standard only
requires that events are issued."
::= { cgspLinkTableEntry 94 }
cgspLinkQ752T2E19 OBJECT-TYPE
SYNTAX Counter32
UNITS "occurrences"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of remote uninhibition Q752/2.19. The standard only
requires that events are issued."
::= { cgspLinkTableEntry 95 }
cgspLinkRxCongestionState OBJECT-TYPE
SYNTAX Unsigned32 (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Signalling link Received Side congestion status of this
link.
0 abate, 1 onset is the received side congestion level"
::= { cgspLinkTableEntry 96 }
-- *************************************************************
-- * *
-- * Link Timer Table *
-- * *
-- *************************************************************
cgspLinkTimerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspLinkTimerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the timer used to configure timer
values specific to a particular Link. Entries are added
to this table via cgspLinkTimerRowStatus in accordance
with the RowStatus convention."
::= { cgspLink 2 }
cgspLinkTimerTableEntry OBJECT-TYPE
SYNTAX CgspLinkTimerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure all MTP3 timer
values that apply to links. The values apply
to a particular link."
INDEX {
cgspInstNetwork,
cgspLinksetName,
cgspLinkSlc,
cgspLinkTimerNumber
}
::= { cgspLinkTimerTable 1 }
CgspLinkTimerTableEntry ::= SEQUENCE {
cgspLinkTimerNumber CgspTimerNumbers,
cgspLinkTimerValue CgspTimerValue,
cgspLinkTimerRowStatus RowStatus
}
cgspLinkTimerNumber OBJECT-TYPE
SYNTAX CgspTimerNumbers
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into table containing timer information."
::= { cgspLinkTimerTableEntry 1 }
cgspLinkTimerValue OBJECT-TYPE
SYNTAX CgspTimerValue
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of timer selected by cgspLinkTimerNumber object."
::= { cgspLinkTimerTableEntry 2 }
cgspLinkTimerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to
create or delete the row entry in cgspLinkTimerTable
following the RowStatus textual convention."
::= { cgspLinkTimerTableEntry 3 }
-- *************************************************************
-- * *
-- * Link Remote Ip Address Table *
-- * *
-- *************************************************************
cgspLinkRemoteIpAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspLinkRemoteIpAddrTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the remote IP addresses used to
configure a particular Link. Entries are added
to this table via cgspLinkRemoteIpAddrRowStatus in
accordance with the RowStatus convention."
::= { cgspLink 3 }
cgspLinkRemoteIpAddrTableEntry OBJECT-TYPE
SYNTAX CgspLinkRemoteIpAddrTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of remote IP addresses per Link."
INDEX {
cgspInstNetwork,
cgspLinksetName,
cgspLinkSlc,
cgspLinkRemoteIpAddrNumber
}
::= { cgspLinkRemoteIpAddrTable 1 }
CgspLinkRemoteIpAddrTableEntry ::= SEQUENCE {
cgspLinkRemoteIpAddrNumber Unsigned32,
cgspLinkRemoteIpAddrType InetAddressType,
cgspLinkRemoteIpAddress InetAddress,
cgspLinkRemoteIpAddrRowStatus RowStatus
}
cgspLinkRemoteIpAddrNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the index for the IP
addresses in the remote IP Address table"
::= { cgspLinkRemoteIpAddrTableEntry 1 }
cgspLinkRemoteIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object contains the type of the local
IP address used to create an association."
::= { cgspLinkRemoteIpAddrTableEntry 2 }
cgspLinkRemoteIpAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object contains the remote IP address used to
create the association with the partner of this
association."
::= { cgspLinkRemoteIpAddrTableEntry 3 }
cgspLinkRemoteIpAddrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object is used by a management station to create
or delete the row entry in cgspLinkRemoteIpAddrTable
following the RowStatus textual convention."
::= { cgspLinkRemoteIpAddrTableEntry 4 }
-- *************************************************************
-- * *
-- * Link Utilization table *
-- * *
-- *************************************************************
cgspLinkUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF CgspLinkUtilTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains a history of the
cgspLinkUtilizationRcvd and cgspLinkUtilizationRcvd
objects. In order to properly manage network capacity
it is necessary to collect utilization information during
short interval. These intervals are less than 5 minutes and
can be as low as 1 minute. The number of links supported by
a signalling point prevent polling each signalling point
to collect information. This table is provided to allow an
NMS to collect the information during a normal poll cycle."
::= { cgspLink 4 }
cgspLinkUtilTableEntry OBJECT-TYPE
SYNTAX CgspLinkUtilTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of entries used to store a history
link utilization values. Values from
cgspLinkUtilizationRcvd and cgspLinkUtilizationSent
objects are saved in cgspLinkUtilRcvd and
cgspLinkUtilSent."
INDEX {
cgspInstNetwork,
cgspLinksetName,
cgspLinkSlc,
cgspLinkUtilIndex
}
::= { cgspLinkUtilTable 1 }
CgspLinkUtilTableEntry ::= SEQUENCE {
cgspLinkUtilIndex Unsigned32,
cgspLinkUtilRcvd CgspLinkUtilization,
cgspLinkUtilSent CgspLinkUtilization,
cgspLinkUtilEndTimestamp TimeStamp
}
cgspLinkUtilIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..60)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index used to access historical link utilization
information. Entry one corresponds to the most
recent utilization window for the length of time
specified by the cgspUtilSampleInterval object.
Example of utilization history using default values.
Current Time: 10:42 am Sample Interval: 300 seconds
cgspLinkUtilIndex
[1] Window from 10:36-10:41
[2] Window from 10:31-10:36
[3] Window from 10:26-10:31
.
.
[n]
The index ranges from one to a maximum of sixty entries.
The actual number of entries will depend on the
implementation and available resources."
::= { cgspLinkUtilTableEntry 1 }
cgspLinkUtilRcvd OBJECT-TYPE
SYNTAX CgspLinkUtilization
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the utilization of this link for traffic
received on this link in the time period defined
by the cgspUtilSampleInterval object."
::= { cgspLinkUtilTableEntry 2 }
cgspLinkUtilSent OBJECT-TYPE
SYNTAX CgspLinkUtilization
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the utilization of this link for traffic
transmitted on this link in the time period defined
by the cgspUtilSampleInterval object."
::= { cgspLinkUtilTableEntry 3 }
cgspLinkUtilEndTimestamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This timestamp indicates when time period ended
for this sample."
::= { cgspLinkUtilTableEntry 4 }
-- *************************************************************
-- * *
-- * GSP - Notification Enable Objects *
-- * *
-- *************************************************************
cgspLsStateChangeNotifEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The signalling point linkset notification truth
value.
'true' Indicates that ciscoGspLinksetStateChange
notification is to be generated when the state
changes. That is, the notification generation
is enabled.
'false' Indicates that ciscoGspLinksetStateChange
notification generation is disabled."
DEFVAL { false }
::= { cgspNotificationsEnable 1 }
cgspLnkStateChangeNotifEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The signalling point link notification truth value.
'true' Indicates that ciscoGspLinkStateChange
notification is to be generated when the state
changes. That is, the notification generation
is enabled.
'false' Indicates that ciscoGspLinkStateChange
notification generation is disabled."
DEFVAL { false }
::= { cgspNotificationsEnable 2 }
cgspCongestionNotifEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The signalling point congestion notification truth
value.
'true' Indicates that ciscoGspCongestionChange and
ciscoGspRxCongestionChange notification is to be
generated when the state changes. That is, the
notification generation is enabled.
'false' Indicates that ciscoGspCongestionChange and
ciscoGspRxCongestionChange notification generation is
disabled."
DEFVAL { false }
::= { cgspNotificationsEnable 3 }
cgspLinkUtilNotifEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The signalling point link utilization notification
truth value.
'true' Indicates that the notification of link
utilization has been enabled. That is,
the notification generation is enabled.
'false' Indicates that the notification link
utilization has been disabled."
DEFVAL { false }
::= { cgspNotificationsEnable 4 }
cgspIsolationNotifEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The isolation notification truth value.
'true' Indicates that the notification of
isolation has been enabled. That is,
the notification generation is enabled.
'false' Indicates that the notification
of isolation has been disabled."
DEFVAL { false }
::= { cgspNotificationsEnable 5 }
cgspUPUNotifEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A control to enable or disable both ciscoGspUPUReceived
and ciscoGspUPUTransmitted notifications as follows:
'true' Indicates that the ciscoGspUPUReceived and
ciscoGspUPUTransmitted notification generation
is enabled.
'false' Indicates that ciscoGspUPUReceived and
ciscoGspUPUTransmitted notification generation
is disabled."
DEFVAL { false }
::= { cgspNotificationsEnable 6 }
-- *************************************************************
-- * *
-- * Notifications Information *
-- * *
-- *************************************************************
cgspUPUIntervalDuration OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Duration elapsed since the start of the cgspUPUNotifWindowTime
interval. This duration value can range from 0 upto
cgspUPUNotifWindowTime. For the notifications generated
at the end of the interval, this value will be equal to
cgspUPUNotifWindowTime."
::= { cgspNotificationsInfo 1 }
cgspIntervalUPUs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "MSUs"
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Number of UPU MSUs received or transmitted during this
specific cgspUPUIntervalDuration interval."
::= { cgspNotificationsInfo 2 }
-- *************************************************************
-- * *
-- * Notifications *
-- * *
-- *************************************************************
ciscoGspLinksetStateChange NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspLinksetDisplayName,
cgspLinksetSourceDisplayPC,
cgspLinksetAdjacentDisplayPC,
cgspLinksetState
}
STATUS current
DESCRIPTION
"The notification generated when a linkset
changes to a new state. The value of
cgspLinksetState indicates the new state."
::= { ciscoGspMIBNotifs 1 }
ciscoGspLinkStateChange NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspLinksetSourceDisplayPC,
cgspLinksetAdjacentDisplayPC,
cgspLinkDisplayName,
cgspLinkState,
cgspLinkReason,
cgspLinkTestResult
}
STATUS current
DESCRIPTION
"The notification generated when a link
changes to a new state. The value of
cgspLinkState indicates the new state."
::= { ciscoGspMIBNotifs 2 }
ciscoGspCongestionChange NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspLinksetSourceDisplayPC,
cgspLinksetAdjacentDisplayPC,
cgspLinkDisplayName,
cgspLinkCongestionState
}
STATUS current
DESCRIPTION
"The notification generated when a link
changes to a new congestion level as specified
by cgspLinkCongestionState object for Transmission Side
congestion."
::= { ciscoGspMIBNotifs 3 }
ciscoGspLinkRcvdUtilChange NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspLinksetSourceDisplayPC,
cgspLinksetAdjacentDisplayPC,
cgspLinkDisplayName,
cgspLinkUtilStateRcvd,
cgspLinkUtilizationRcvd
}
STATUS current
DESCRIPTION
"The notification provide is generated when
the cgspLinkUtilStateRcvd changes states."
::= { ciscoGspMIBNotifs 4 }
ciscoGspLinkSentUtilChange NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspLinksetSourceDisplayPC,
cgspLinksetAdjacentDisplayPC,
cgspLinkDisplayName,
cgspLinkUtilStateSent,
cgspLinkUtilizationSent
}
STATUS current
DESCRIPTION
"The notification provide is generated when
the cgspLinkUtilStateSent changes states."
::= { ciscoGspMIBNotifs 5 }
ciscoGspIsolation NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspInstDisplayName,
cgspInstDescription
}
STATUS current
DESCRIPTION
"This notification indicates the instance specified
by cgspInstDisplayName and cgspInstDescription has
become isolated. All linkset used to connect MTP3 node
(instance) are unavailable. Isolation is ended when
any linkset supported by this instance reaches the
active state."
::= { ciscoGspMIBNotifs 6 }
ciscoGspUPUReceived NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspInstUserPartDisplay,
cgspUPUIntervalDuration,
cgspIntervalUPUs
}
STATUS current
DESCRIPTION
"The notification is generated when an UPU MSU is received
from a remote signalling point, for a specific instance
and user part for the first time in the configured
cgspUPUNotifWindowTime. For cases when there is a non-zero
number of UPU MSUs received, this notification will be sent
at the end of the cgspUPUNotifWindowTime interval, with
cgspIntervalUPUs indicating the total count of UPU
MSUs received for that specific instance and user part
during the entire cgspUPUNotifWindowTime interval Q752/5.6."
::= { ciscoGspMIBNotifs 8 }
ciscoGspUPUTransmitted NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspInstUserPartDisplay,
cgspUPUIntervalDuration,
cgspIntervalUPUs
}
STATUS current
DESCRIPTION
"The notification is generated when an UPU MSU is transmitted
to a remote signalling point, for a specific instance and
user part for the first time in the configured
cgspUPUNotifWindowTime. For cases when there is a non-zero
number of UPU MSUs received, this notification will be sent
at the end of the cgspUPUNotifWindowTime interval, with
cgspIntervalUPUs indicating the total count of UPU MSUs
transmitted for that specific instance and user part
during the entire cgspUPUNotifWindowTime interval Q752/5.7."
::= { ciscoGspMIBNotifs 9 }
ciscoGspRxCongestionChange NOTIFICATION-TYPE
OBJECTS {
cgspEventSequenceNumber,
cgspCLLICode,
cgspLinksetSourceDisplayPC,
cgspLinksetAdjacentDisplayPC,
cgspLinkDisplayName,
cgspLinkRxCongestionState
}
STATUS current
DESCRIPTION
"The notification generated when a link
changes to a new congestion level as specified
by cgspLinkRxCongestionstate object for Received side
congestion"
::= { ciscoGspMIBNotifs 10 }
-- Conformance Information
ciscoGspMIBCompliances OBJECT IDENTIFIER
::= { ciscoGspMIBConform 1 }
ciscoGspMIBGroups OBJECT IDENTIFIER
::= { ciscoGspMIBConform 2 }
-- Compliance
ciscoGspMIBCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement
the CISCO-ITP-GSP-MIB"
MODULE -- this module
MANDATORY-GROUPS {
ciscoGspScalarsGroup,
ciscoGspProfileGroup,
ciscoGspInstanceGroup,
ciscoGspInstTimerGroup,
ciscoGspPointCodeGroup,
ciscoGspLinksetGroup,
ciscoGspLinksetTimerGroup,
ciscoGspLinkGroup,
ciscoGspLinkTimerGroup,
ciscoGspLinkRemoteIpGroup,
ciscoGspLinkUtilGroup,
ciscoGspNotificationsEnableGroup,
ciscoGspNotificationsGroup
}
OBJECT cgspCLLICode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilSampleInterval
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilThreshold
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilAbateDelta
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPlanCapacityDefault
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2BundleTimer
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2SendQueueDepth
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstNetworkIndicator
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTFR
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstCongestionsLevels
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstFastRestart
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDistSccpUnseq
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstSummaryRoutingException
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRouteTableName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetSourcePointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAdjacentPointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetInboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetOutboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingMtp3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingGtt
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetActPriority
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsEnable
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsShift
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetProfileName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkifIndex
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkXmitQueueDepthHigh
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkSigLinkTest
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkLocalPeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemotePeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkQosClass
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacityRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacitySent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdSent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddress
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
::= { ciscoGspMIBCompliances 1 }
ciscoGspMIBComplianceRev1 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement
the CISCO-ITP-GSP-MIB"
MODULE -- this module
MANDATORY-GROUPS {
ciscoGspScalarsGroup,
ciscoGspProfileGroup,
ciscoGspInstanceGroup,
ciscoGspInstTimerGroup,
ciscoGspPointCodeGroup,
ciscoGspLinksetGroup,
ciscoGspLinksetTimerGroup,
ciscoGspLinkTimerGroup,
ciscoGspLinkRemoteIpGroup,
ciscoGspLinkUtilGroup,
ciscoGspNotificationsEnableGroup,
ciscoGspNotificationsGroup,
ciscoGspLinkGroupRev1
}
OBJECT cgspCLLICode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilSampleInterval
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilThreshold
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilAbateDelta
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPlanCapacityDefault
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2BundleTimer
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2SendQueueDepth
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstNetworkIndicator
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTFR
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstCongestionsLevels
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstFastRestart
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDistSccpUnseq
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstSummaryRoutingException
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRouteTableName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetSourcePointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAdjacentPointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetInboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetOutboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingMtp3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingGtt
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetActPriority
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsEnable
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsShift
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetProfileName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkifIndex
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkXmitQueueDepthHigh
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkSigLinkTest
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkLocalPeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemotePeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkQosClass
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacityRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacitySent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdSent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddress
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
::= { ciscoGspMIBCompliances 2 }
ciscoGspMIBComplianceRev2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement
the CISCO-ITP-GSP-MIB"
MODULE -- this module
MANDATORY-GROUPS {
ciscoGspScalarsGroup,
ciscoGspProfileGroup,
ciscoGspInstanceGroup,
ciscoGspInstTimerGroup,
ciscoGspPointCodeGroup,
ciscoGspLinksetGroup,
ciscoGspLinksetTimerGroup,
ciscoGspLinkTimerGroup,
ciscoGspLinkRemoteIpGroup,
ciscoGspLinkUtilGroup,
ciscoGspNotificationsEnableGroup,
ciscoGspNotificationsGroup,
ciscoGspLinkGroupRev1,
ciscoGspNotificationsEnableGroupSup1,
ciscoGspNotificationsGroupSup1
}
OBJECT cgspCLLICode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilSampleInterval
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilThreshold
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilAbateDelta
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPlanCapacityDefault
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2BundleTimer
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2SendQueueDepth
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstNetworkIndicator
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTFR
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstCongestionsLevels
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstFastRestart
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDistSccpUnseq
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstSummaryRoutingException
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRouteTableName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetSourcePointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAdjacentPointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetInboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetOutboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingMtp3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingGtt
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetActPriority
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsEnable
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsShift
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetProfileName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkifIndex
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkXmitQueueDepthHigh
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkSigLinkTest
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkLocalPeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemotePeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkQosClass
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacityRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacitySent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdSent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddress
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
::= { ciscoGspMIBCompliances 3 }
ciscoGspMIBComplianceRev3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement
the CISCO-ITP-GSP-MIB"
MODULE -- this module
MANDATORY-GROUPS {
ciscoGspScalarsGroup,
ciscoGspProfileGroup,
ciscoGspInstanceGroup,
ciscoGspInstTimerGroup,
ciscoGspPointCodeGroup,
ciscoGspLinksetGroup,
ciscoGspLinksetTimerGroup,
ciscoGspLinkTimerGroup,
ciscoGspLinkRemoteIpGroup,
ciscoGspLinkUtilGroup,
ciscoGspNotificationsEnableGroup,
ciscoGspNotificationsGroup,
ciscoGspLinkGroupRev1,
ciscoGspNotificationsEnableGroupSup1,
ciscoGspNotificationsGroupSup1,
ciscoGspLinkGroupSup1,
ciscoGspScalarsGroupSup1,
ciscoGspInstUPUGroup,
ciscoGspNotificationsInfoGroup,
ciscoGspNotificationsEnableGroupSup2,
ciscoGspNotificationsGroupSup2
}
OBJECT cgspCLLICode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilSampleInterval
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilThreshold
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilAbateDelta
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPlanCapacityDefault
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2BundleTimer
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2SendQueueDepth
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstNetworkIndicator
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTFR
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstCongestionsLevels
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstFastRestart
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDistSccpUnseq
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstSummaryRoutingException
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRouteTableName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetSourcePointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAdjacentPointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetInboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetOutboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingMtp3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingGtt
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetActPriority
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsEnable
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsShift
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetProfileName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkifIndex
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkXmitQueueDepthHigh
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkSigLinkTest
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkLocalPeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemotePeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkQosClass
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacityRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacitySent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdSent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddress
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
::= { ciscoGspMIBCompliances 4 }
ciscoGspMIBComplianceRev4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement
the CISCO-ITP-GSP-MIB"
MODULE -- this module
MANDATORY-GROUPS {
ciscoGspScalarsGroup,
ciscoGspProfileGroup,
ciscoGspInstanceGroup,
ciscoGspInstTimerGroup,
ciscoGspPointCodeGroup,
ciscoGspLinksetGroup,
ciscoGspLinksetTimerGroup,
ciscoGspLinkTimerGroup,
ciscoGspLinkRemoteIpGroup,
ciscoGspLinkUtilGroup,
ciscoGspNotificationsEnableGroup,
ciscoGspNotificationsGroup,
ciscoGspLinkGroupRev1,
ciscoGspNotificationsEnableGroupSup1,
ciscoGspNotificationsGroupSup1,
ciscoGspLinkGroupSup1,
ciscoGspScalarsGroupSup1,
ciscoGspInstUPUGroup,
ciscoGspNotificationsInfoGroup,
ciscoGspNotificationsEnableGroupSup2,
ciscoGspNotificationsGroupSup2,
ciscoGspInstSccpWrrGroup
}
OBJECT cgspCLLICode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilSampleInterval
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilThreshold
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspUtilAbateDelta
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPlanCapacityDefault
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2BundleTimer
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileMtp2SendQueueDepth
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspProfileTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstNetworkIndicator
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTFR
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstCongestionsLevels
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstFastRestart
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstDistSccpUnseq
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstSummaryRoutingException
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRouteTableName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspInstTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspPointCodeRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetSourcePointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAdjacentPointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetInboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetOutboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingMtp3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingGtt
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetActPriority
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsEnable
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsShift
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetProfileName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkifIndex
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkXmitQueueDepthHigh
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkSigLinkTest
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkLocalPeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemotePeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkQosClass
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacityRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacitySent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdSent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddress
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
::= { ciscoGspMIBCompliances 5 }
ciscoGspMIBComplianceRev5 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the CISCO-ITP-GSP-MIB"
MODULE -- this module
MANDATORY-GROUPS {
ciscoGspScalarsGroup,
ciscoGspProfileGroup,
ciscoGspInstanceGroup,
ciscoGspInstTimerGroup,
ciscoGspPointCodeGroup,
ciscoGspLinksetGroup,
ciscoGspLinksetTimerGroup,
ciscoGspLinkTimerGroup,
ciscoGspLinkRemoteIpGroup,
ciscoGspLinkUtilGroup,
ciscoGspNotificationsEnableGroup,
ciscoGspNotificationsGroup,
ciscoGspLinkGroupRev1,
ciscoGspNotificationsEnableGroupSup1,
ciscoGspNotificationsGroupSup1,
ciscoGspLinkGroupSup1,
ciscoGspScalarsGroupSup1,
ciscoGspInstUPUGroup,
ciscoGspNotificationsInfoGroup,
ciscoGspNotificationsEnableGroupSup2,
ciscoGspNotificationsGroupSup2,
ciscoGspInstSccpWrrGroup,
ciscoGspLinkTableEntryGroupSup1,
ciscoGspNotificationsGroupSup3
}
OBJECT cgspCLLICode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspUtilSampleInterval
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspUtilThreshold
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspUtilAbateDelta
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspPlanCapacityDefault
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspProfileVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspProfileMtp2BundleTimer
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspProfileMtp2SendQueueDepth
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspProfileRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspProfileTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspProfileTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstNetworkIndicator
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstVariant
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstTFR
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstCongestionsLevels
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstFastRestart
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstDistSccpUnseq
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstSummaryRoutingException
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstRouteTableName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspInstTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspPointCodeType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspPointCodeRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required"
OBJECT cgspLinksetSourcePointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAdjacentPointCode
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetInboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetOutboundAcl
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingMtp3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetAccountingGtt
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetActPriority
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsEnable
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRotateSlsShift
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetProfileName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinksetDescription
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkifIndex
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkXmitQueueDepthHigh
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionAbate3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset1
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset2
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkCongestionOnset3
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkSigLinkTest
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkLocalPeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemotePeerPort
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkQosClass
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkDisplayName
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacityRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdRcvd
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkPlanCapacitySent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkUtilThresholdSent
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerValue
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkTimerRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrType
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddress
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRemoteIpAddrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
OBJECT cgspLinkRxCongestionState
MIN-ACCESS read-only
DESCRIPTION
"Create/Write access is not required."
::= { ciscoGspMIBCompliances 6 }
-- Units of Conformance
ciscoGspScalarsGroup OBJECT-GROUP
OBJECTS {
cgspCLLICode,
cgspUtilSampleInterval,
cgspUtilThreshold,
cgspUtilAbateDelta,
cgspPlanCapacityDefault,
cgspEventSequenceNumber
}
STATUS current
DESCRIPTION
"Scalars Group for Gateway Signalling Point."
::= { ciscoGspMIBGroups 1 }
ciscoGspProfileGroup OBJECT-GROUP
OBJECTS {
cgspProfileVariant,
cgspProfileMtp2BundleTimer,
cgspProfileMtp2SendQueueDepth,
cgspProfileRowStatus,
cgspProfileTimerValue,
cgspProfileTimerRowStatus
}
STATUS current
DESCRIPTION
"Profile Group for Gateway Signalling Point."
::= { ciscoGspMIBGroups 2 }
ciscoGspInstanceGroup OBJECT-GROUP
OBJECTS {
cgspInstNetworkIndicator,
cgspInstVariant,
cgspInstDisplayName,
cgspInstDescription,
cgspInstTFR,
cgspInstCongestionsLevels,
cgspInstFastRestart,
cgspInstDistSccpUnseq,
cgspInstSummaryRoutingException,
cgspInstNumber,
cgspInstRouteTableName,
cgspInstRowStatus
}
STATUS current
DESCRIPTION
"Instance of Signalling Point."
::= { ciscoGspMIBGroups 3 }
ciscoGspInstTimerGroup OBJECT-GROUP
OBJECTS {
cgspInstTimerValue,
cgspInstTimerRowStatus
}
STATUS current
DESCRIPTION
"Timers defined for each Instance of Signalling
Point."
::= { ciscoGspMIBGroups 4 }
ciscoGspPointCodeGroup OBJECT-GROUP
OBJECTS {
cgspPointCodeType,
cgspPointCodeDisplay,
cgspPointCodeRowStatus
}
STATUS current
DESCRIPTION
"Pointcode defined for each Instance of
Signalling Point."
::= { ciscoGspMIBGroups 5 }
ciscoGspLinksetGroup OBJECT-GROUP
OBJECTS {
cgspLinksetSourcePointCode,
cgspLinksetSourceDisplayPC,
cgspLinksetAdjacentPointCode,
cgspLinksetAdjacentDisplayPC,
cgspLinksetState,
cgspLinksetInboundAcl,
cgspLinksetOutboundAcl,
cgspLinksetAccountingMtp3,
cgspLinksetAccountingGtt,
cgspLinksetNumLinks,
cgspLinksetDurationInService,
cgspLinksetDurationOutService,
cgspLinksetActPriority,
cgspLinksetDisplayName,
cgspLinksetDescription,
cgspLinksetRotateSlsEnable,
cgspLinksetRotateSlsShift,
cgspLinksetProfileName,
cgspLinksetAdjacentInst,
cgspLinksetRowStatus
}
STATUS current
DESCRIPTION
"linkset objects ."
::= { ciscoGspMIBGroups 6 }
ciscoGspLinksetTimerGroup OBJECT-GROUP
OBJECTS {
cgspLinksetTimerValue,
cgspLinksetTimerRowStatus
}
STATUS current
DESCRIPTION
"Timers defined for each Linkset."
::= { ciscoGspMIBGroups 7 }
ciscoGspLinkGroup OBJECT-GROUP
OBJECTS {
cgspLinkDescription,
cgspLinkState,
cgspLinkReason,
cgspLinkType,
cgspLinkifIndex,
cgspLinkSctpAssociation,
cgspLinkXmitQueueDepth,
cgspLinkXmitQueueDepthHigh,
cgspLinkXmitQueueDepthHighRT,
cgspLinkCongestionState,
cgspLinkCongestionAbate1,
cgspLinkCongestionAbate2,
cgspLinkCongestionAbate3,
cgspLinkCongestionOnset1,
cgspLinkCongestionOnset2,
cgspLinkCongestionOnset3,
cgspLinkSigLinkTest,
cgspLinkQ752T1E1,
cgspLinkQ752T1E2,
cgspLinkQ752T1E3,
cgspLinkQ752T1E5,
cgspLinkQ752T1E7,
cgspLinkQ752T1E8,
cgspLinkQ752T1E9,
cgspLinkQ752T1E10,
cgspLinkQ752T1E11,
cgspLinkQ752T2E1,
cgspLinkQ752T2E5,
cgspLinkQ752T2E6,
cgspLinkQ752T2E7,
cgspLinkQ752T2E9,
cgspLinkQ752T2E10,
cgspLinkQ752T2E15,
cgspLinkQ752T2E16,
cgspLinkQ752T2E18,
cgspLinkQ752T3E1,
cgspLinkQ752T3E2Packets,
cgspLinkQ752T3E2Bytes,
cgspLinkQ752T3E3,
cgspLinkQ752T3E4,
cgspLinkQ752T3E5,
cgspLinkQ752T3E6,
cgspLinkQ752T3E7,
cgspLinkQ752T3E10L1,
cgspLinkQ752T3E10L2,
cgspLinkQ752T3E10L3,
cgspLinkQ752T3E11L1,
cgspLinkQ752T3E11L2,
cgspLinkQ752T3E11L3,
cgspLinkLocalPeerPort,
cgspLinkRemotePeerPort,
cgspLinkQosClass,
cgspLinkDisplayName,
cgspLinkDroppedPkts,
cgspLinkTransmittedLSSUs,
cgspLinkReceivedLSSUs,
cgspLinkProtocolDetails,
cgspLinkLsacState,
cgspLinkTsrcState,
cgspLinkTcocState,
cgspLinkTcocLocalBSNT,
cgspLinkTcocRemoteBSNT,
cgspLinkTcbcState,
cgspLinkReceivedSIBs,
cgspLinkTransmittedSIBs,
cgspLinkMtp2T01Counts,
cgspLinkMtp2T02Counts,
cgspLinkMtp2T03Counts,
cgspLinkMtp2T04Counts,
cgspLinkMtp2T05Counts,
cgspLinkMtp2T06Counts,
cgspLinkMtp2T07Counts,
cgspLinkOMAERMCounts,
cgspLinkOMAERMFailCounts,
cgspLinkOMSURMCounts,
cgspLinkOMSURMFailCounts,
cgspLinkPlanCapacityRcvd,
cgspLinkUtilThresholdRcvd,
cgspLinkUtilizationRcvd,
cgspLinkUtilStateRcvd,
cgspLinkL2BytesRcvd,
cgspLinkPlanCapacitySent,
cgspLinkUtilThresholdSent,
cgspLinkUtilizationSent,
cgspLinkUtilStateSent,
cgspLinkL2BytesSent,
cgspLinkTestResult,
cgspLinkRowStatus
}
STATUS deprecated
DESCRIPTION
"SP link objects."
::= { ciscoGspMIBGroups 8 }
ciscoGspLinkTimerGroup OBJECT-GROUP
OBJECTS {
cgspLinkTimerValue,
cgspLinkTimerRowStatus
}
STATUS current
DESCRIPTION
"Timers defined for each Link."
::= { ciscoGspMIBGroups 9 }
ciscoGspLinkRemoteIpGroup OBJECT-GROUP
OBJECTS {
cgspLinkRemoteIpAddrType,
cgspLinkRemoteIpAddress,
cgspLinkRemoteIpAddrRowStatus
}
STATUS current
DESCRIPTION
"Remote IP addresses for each Link."
::= { ciscoGspMIBGroups 10 }
ciscoGspLinkUtilGroup OBJECT-GROUP
OBJECTS {
cgspLinkUtilRcvd,
cgspLinkUtilSent,
cgspLinkUtilEndTimestamp
}
STATUS current
DESCRIPTION
"Utilization history for each Link."
::= { ciscoGspMIBGroups 11 }
ciscoGspNotificationsEnableGroup OBJECT-GROUP
OBJECTS {
cgspLsStateChangeNotifEnabled,
cgspLnkStateChangeNotifEnabled,
cgspCongestionNotifEnabled,
cgspLinkUtilNotifEnabled
}
STATUS current
DESCRIPTION
"SP enable notification objects."
::= { ciscoGspMIBGroups 12 }
ciscoGspNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
ciscoGspLinksetStateChange,
ciscoGspLinkStateChange,
ciscoGspCongestionChange,
ciscoGspLinkRcvdUtilChange,
ciscoGspLinkSentUtilChange
}
STATUS current
DESCRIPTION
"SP notifications."
::= { ciscoGspMIBGroups 13 }
ciscoGspLinkGroupRev1 OBJECT-GROUP
OBJECTS {
cgspLinkDescription,
cgspLinkState,
cgspLinkReason,
cgspLinkType,
cgspLinkifIndex,
cgspLinkXmitQueueDepth,
cgspLinkXmitQueueDepthHigh,
cgspLinkXmitQueueDepthHighRT,
cgspLinkCongestionState,
cgspLinkCongestionAbate1,
cgspLinkCongestionAbate2,
cgspLinkCongestionAbate3,
cgspLinkCongestionOnset1,
cgspLinkCongestionOnset2,
cgspLinkCongestionOnset3,
cgspLinkSigLinkTest,
cgspLinkQ752T1E1,
cgspLinkQ752T1E2,
cgspLinkQ752T1E3,
cgspLinkQ752T1E5,
cgspLinkQ752T1E7,
cgspLinkQ752T1E8,
cgspLinkQ752T1E9,
cgspLinkQ752T1E10,
cgspLinkQ752T1E11,
cgspLinkQ752T2E1,
cgspLinkQ752T2E5,
cgspLinkQ752T2E6,
cgspLinkQ752T2E7,
cgspLinkQ752T2E9,
cgspLinkQ752T2E10,
cgspLinkQ752T2E15,
cgspLinkQ752T2E16,
cgspLinkQ752T2E18,
cgspLinkQ752T3E1,
cgspLinkQ752T3E2Packets,
cgspLinkQ752T3E2Bytes,
cgspLinkQ752T3E3,
cgspLinkQ752T3E4,
cgspLinkQ752T3E5,
cgspLinkQ752T3E6,
cgspLinkQ752T3E7,
cgspLinkQ752T3E10L1,
cgspLinkQ752T3E10L2,
cgspLinkQ752T3E10L3,
cgspLinkQ752T3E11L1,
cgspLinkQ752T3E11L2,
cgspLinkQ752T3E11L3,
cgspLinkLocalPeerPort,
cgspLinkRemotePeerPort,
cgspLinkQosClass,
cgspLinkDisplayName,
cgspLinkDroppedPkts,
cgspLinkTransmittedLSSUs,
cgspLinkReceivedLSSUs,
cgspLinkProtocolDetails,
cgspLinkLsacState,
cgspLinkTsrcState,
cgspLinkTcocState,
cgspLinkTcocLocalBSNT,
cgspLinkTcocRemoteBSNT,
cgspLinkTcbcState,
cgspLinkReceivedSIBs,
cgspLinkTransmittedSIBs,
cgspLinkMtp2T01Counts,
cgspLinkMtp2T02Counts,
cgspLinkMtp2T03Counts,
cgspLinkMtp2T04Counts,
cgspLinkMtp2T05Counts,
cgspLinkMtp2T06Counts,
cgspLinkMtp2T07Counts,
cgspLinkOMAERMCounts,
cgspLinkOMAERMFailCounts,
cgspLinkOMSURMCounts,
cgspLinkOMSURMFailCounts,
cgspLinkPlanCapacityRcvd,
cgspLinkUtilThresholdRcvd,
cgspLinkUtilizationRcvd,
cgspLinkUtilStateRcvd,
cgspLinkL2BytesRcvd,
cgspLinkPlanCapacitySent,
cgspLinkUtilThresholdSent,
cgspLinkUtilizationSent,
cgspLinkUtilStateSent,
cgspLinkL2BytesSent,
cgspLinkTestResult,
cgspLinkRowStatus,
cgspLinkSctpAssociationId
}
STATUS current
DESCRIPTION
"SP link objects."
::= { ciscoGspMIBGroups 14 }
ciscoGspNotificationsEnableGroupSup1 OBJECT-GROUP
OBJECTS { cgspIsolationNotifEnabled }
STATUS current
DESCRIPTION
"Isolation notification enable."
::= { ciscoGspMIBGroups 15 }
ciscoGspNotificationsGroupSup1 NOTIFICATION-GROUP
NOTIFICATIONS { ciscoGspIsolation }
STATUS current
DESCRIPTION
"Isolation notification."
::= { ciscoGspMIBGroups 16 }
ciscoGspLinkGroupSup1 OBJECT-GROUP
OBJECTS {
cgspLinkQ752T1E12,
cgspLinkQ752T1E12Errors,
cgspLinkQ752T2E11,
cgspLinkQ752T2E17,
cgspLinkQ752T2E19
}
STATUS current
DESCRIPTION
"Additional Link statistics."
::= { ciscoGspMIBGroups 17 }
ciscoGspScalarsGroupSup1 OBJECT-GROUP
OBJECTS { cgspUPUNotifWindowTime }
STATUS current
DESCRIPTION
"Scalar Group supplements."
::= { ciscoGspMIBGroups 18 }
ciscoGspInstUPUGroup OBJECT-GROUP
OBJECTS {
cgspInstSIUPUReceived,
cgspInstSIUPUTransmitted,
cgspInstUserPartDisplay
}
STATUS current
DESCRIPTION
"SS7 Destination and Service Indicator group."
::= { ciscoGspMIBGroups 20 }
ciscoGspNotificationsInfoGroup OBJECT-GROUP
OBJECTS {
cgspUPUIntervalDuration,
cgspIntervalUPUs
}
STATUS current
DESCRIPTION
"Notifications Info Group."
::= { ciscoGspMIBGroups 21 }
ciscoGspNotificationsEnableGroupSup2 OBJECT-GROUP
OBJECTS { cgspUPUNotifEnabled }
STATUS current
DESCRIPTION
"UPU notifications enable."
::= { ciscoGspMIBGroups 22 }
ciscoGspNotificationsGroupSup2 NOTIFICATION-GROUP
NOTIFICATIONS {
ciscoGspUPUReceived,
ciscoGspUPUTransmitted
}
STATUS current
DESCRIPTION
"Adjacent SP accessibility notification,
UPU sent and received notifications."
::= { ciscoGspMIBGroups 23 }
ciscoGspInstSccpWrrGroup OBJECT-GROUP
OBJECTS {
cgspInstSccpWrrOpcShift,
cgspInstSccpWrrOption
}
STATUS current
DESCRIPTION
"SCCP GTT weighted loadshare group."
::= { ciscoGspMIBGroups 24 }
ciscoGspLinkTableEntryGroupSup1 OBJECT-GROUP
OBJECTS { cgspLinkRxCongestionState }
STATUS current
DESCRIPTION
"cgspLinkRxCongestionstate object for
Received side congestion"
::= { ciscoGspMIBGroups 25 }
ciscoGspNotificationsGroupSup3 NOTIFICATION-GROUP
NOTIFICATIONS { ciscoGspRxCongestionChange }
STATUS current
DESCRIPTION
"Link Receive side congestion notication."
::= { ciscoGspMIBGroups 26 }