snmp_mib_archive/CISCO-FCPING-MIB.my 2
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

602 lines
22 KiB
Plaintext

-- *********************************************************************
-- CISCO-FCPING-MIB.my: Fibre Channel Ping Mib
--
-- September 2002, H K Vivek
--
-- Copyright (c) 2002 by cisco Systems, Inc.
-- All rights reserved.
--
-- *********************************************************************
CISCO-FCPING-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,OBJECT-TYPE,
NOTIFICATION-TYPE,
Gauge32,Unsigned32, Integer32 FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
RowStatus, TruthValue,
TEXTUAL-CONVENTION FROM SNMPv2-TC
ciscoMgmt FROM CISCO-SMI
VsanIndex, FcAddress,
FcAddressType FROM CISCO-ST-TC;
ciscoFcPingMIB MODULE-IDENTITY
LAST-UPDATED "200210070000Z"
ORGANIZATION "Cisco Systems Inc."
CONTACT-INFO
" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553 -NETS
E-mail: cs-san@cisco.com"
DESCRIPTION
"The MIB module for the management of the
Fibre Channel Ping functionality."
REVISION "200210070000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { ciscoMgmt 295 }
ciscoFcPingMIBObjects OBJECT IDENTIFIER ::= { ciscoFcPingMIB 1 }
fcPingMIBConformance OBJECT IDENTIFIER ::= { ciscoFcPingMIB 2 }
fcPingConfiguration OBJECT IDENTIFIER
::= { ciscoFcPingMIBObjects 1 }
fcPingStats OBJECT IDENTIFIER
::= { ciscoFcPingMIBObjects 2 }
fcPingNotification OBJECT IDENTIFIER
::= { ciscoFcPingMIBObjects 3 }
fcPingNotifications OBJECT IDENTIFIER ::= { fcPingNotification 0 }
-- Textual conventions
FcStartOper ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enable/disable an operation.
enable(1) - enable the operation.
disable(2) - disable the operation."
SYNTAX INTEGER {
enable(1),
disable(2)
}
-- Ping Requests Table
fcPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ping request entries.
This table contains a set of ping requests
which need to be executed at the agent."
::= { fcPingConfiguration 1 }
fcPingEntry OBJECT-TYPE
SYNTAX FcPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A ping request entry.
A management station wishing to create an entry
should generate a pseudo-random number to be
used as an index into this table and create an
instance of the fcPingRowStatus object. After that,
the management station should set the corresponding
instance of fcPingAddress object with the address of
the destination that should be pinged and
fcPingVsanIndex with the desired VSAN number.
Once the appropriate instance of all the configuration
objects have been created, either by an explicit SNMP
set request or by default, the row status should be
set to active to initiate the ping sequence. Note that
this entire procedure may be initiated via a single
set request which specifies a row status of
createAndGo as well as specifies valid values for the
non-defaulted configuration objects.
Once the ping sequence has been initiated it can
be stopped by setting the corresponding instance
of fcPingRowStatus to 'destroy'.
The results of the ping operation are made available
in the fcPingStats table. For a ping entry uniquely
identified by fcPingIndex, an entry will be created
in the fcPingStats table automatically by the agent.
Once the ping sequence completes, the management
station should retrieve the statistics of interest
from the fcPingStats table and delete the entry from
the fcPingTable. The corresponding entry in the
fcPingStats table shall be deleted automatically by
the agent.
In order to prevent old entries from clogging the
table, entries will be aged out, but an entry will
never be deleted within fcPingAgeInterval
milliseconds of completing.
If the management station wishes to repeat the ping
sequence to a particular destination, then it will
need to set the corresponding instance of
fcPingAdminStatus to 'enable' again."
INDEX { fcPingIndex }
::= { fcPingTable 1 }
FcPingEntry ::= SEQUENCE {
fcPingIndex Integer32,
fcPingVsanIndex VsanIndex,
fcPingAddressType FcAddressType,
fcPingAddress FcAddress,
fcPingPacketCount Unsigned32,
fcPingPayloadSize Unsigned32,
fcPingPacketTimeout Unsigned32,
fcPingDelay Unsigned32,
fcPingAgeInterval Unsigned32,
fcPingUsrPriority INTEGER,
fcPingAdminStatus FcStartOper,
fcPingOperStatus INTEGER,
fcPingTrapOnCompletion TruthValue,
fcPingRowStatus RowStatus
}
fcPingIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of a ping entry. This object uniquely
identifies a ping request entry on a VSAN."
::= { fcPingEntry 1 }
fcPingVsanIndex OBJECT-TYPE
SYNTAX VsanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the VSAN to which this ping
request belongs. This object cannot be modified
if the corresponding instance of fcPingOperStatus
object has a value of 'inProgress'."
DEFVAL { 1 }
::= { fcPingEntry 2 }
fcPingAddressType OBJECT-TYPE
SYNTAX FcAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The format of the corresponding instance of
fcPingAddress object."
DEFVAL { wwn }
::= { fcPingEntry 3 }
fcPingAddress OBJECT-TYPE
SYNTAX FcAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The address of the device to be pinged.
If the value of the corresponding instance of
fcPingAddressType object is 'wwn', then this
object will contain an 8 octet long WWN.
If the value of the corresponding instance of
fcPingAddressType object is 'fcid', then this
object will contain a 3 octet long FCID.
This object MUST be set to a valid value before
or concurrently with setting the corresponding
instance of fcPingRowStatus to 'active'."
::= { fcPingEntry 4 }
fcPingPacketCount OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of ping packets to be sent to the
target in this sequence. This object cannot
be modified if the corresponding instance
of fcPingOperStatus object has a value of
'inProgress'."
DEFVAL { 5 }
::= { fcPingEntry 5 }
fcPingPayloadSize OBJECT-TYPE
SYNTAX Unsigned32 (0..1884)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the size of the ping packet
payload to be sent to the target in this sequence.
This object cannot be modified if the
corresponding instance of fcPingOperStatus object
has a value of 'inProgress'."
DEFVAL { 0 }
::= { fcPingEntry 6 }
fcPingPacketTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The amount of time to wait for a response to a
transmitted packet before declaring the packet
'dropped'. This object cannot be modified if
the corresponding instance of fcPingOperStatus
object has a value of 'inProgress'."
DEFVAL { 2 }
::= { fcPingEntry 7 }
fcPingDelay OBJECT-TYPE
SYNTAX Unsigned32 (0..3600000)
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum amount of time to wait before sending
the next packet in a sequence, after receiving a
response or declaring a timeout for a previously
transmitted packet. This object cannot be
modified if the corresponding instance of
fcPingOperStatus object has a value of
'inProgress'."
DEFVAL { 0 }
::= { fcPingEntry 8 }
fcPingAgeInterval OBJECT-TYPE
SYNTAX Unsigned32 (500000..900000)
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The amount of time to wait after the ping sequence
completes before the ping entry is aged out.
This object cannot be modified if the
corresponding instance of fcPingOperStatus object
has a value of 'inProgress'."
DEFVAL { 500000 }
::= { fcPingEntry 9 }
fcPingUsrPriority OBJECT-TYPE
SYNTAX INTEGER {
high(1), -- user priority is high
low(2) -- user priority is low
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the queuing priority
and drop probability this sequence of ping
packets experience in the switches through
which they pass through.
If the value of this object is set to 'high',
then the corresponding sequence of packets
will experience high queueing priority and
low drop probability in the switches through
which they pass through.
If the value of this object is set to 'low',
then the corresponding sequence of packets
will experience low queueing priority and
higher drop probability in the switches
through which they pass through.
This object cannot be modified if the
corresponding instance of fcPingOperStatus
object has a value of 'inProgress'."
DEFVAL { low }
::= { fcPingEntry 10 }
fcPingAdminStatus OBJECT-TYPE
SYNTAX FcStartOper
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the desired state that a
fcPingEntry should be in:
enable(1) - Attempt to activate the ping as
defined by this entry.
disable(2) - Deactivate the ping as defined by
this entry.
The actual operational state of this test is
indicated by the corresponding instance of
fcPingOperStatus.
When the ping sequence corresponding to this entry
is executing, this object cannot be modified. If this
object is read at such a time, a value of 'enable'
will be returned. When the ping sequence completes,
the value of this object will be made 'disable'
automatically by the agent."
DEFVAL { disable }
::= { fcPingEntry 11 }
fcPingOperStatus OBJECT-TYPE
SYNTAX INTEGER {
inProgress(1), -- ping is in progress
complete(2), -- ping is complete
disabled(3), -- ping is disabled
failure(4) -- ping failure
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the operational status
of this fcPingEntry.
inProgress(1) - Indicates that the ping sequence
as defined by this instance of
fcPingEntry is currently running.
complete(2) - Indicates that the ping sequence
as defined by this instance of
fcPingEntry is currently
complete.
disabled(3) - Indicates that the ping sequence
as defined by this instance of
fcPingEntry is currently disabled.
failure(4) - Indicates that the ping sequence
as defined by this instance of
fcPingEntry has currently failed
due to resource limitations.
Initially the value of this object will be
'inProgress' when the ping sequence is being
executed. Once the ping sequence is completed,
the value of this object will transition to
'complete'.
If the value of the corresponding instance of
fcPingAdminStatus is 'disable', then this object
will have a value of 'disabled'."
::= { fcPingEntry 12 }
fcPingTrapOnCompletion OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This specifies if fcPingCompletionNotify notification
should be generated or not when the corresponding
ping sequence completes.
If this object is set to 'true', then the
notification is generated.
If this object is set to 'false', then the
notification is not generated.
This object cannot be modified if the
corresponding instance of fcPingOperStatus
object has a value of 'inProgress'."
DEFVAL { false }
::= { fcPingEntry 13 }
fcPingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this conceptual row.
When a ping sequence is being executed, if this
object is set to 'destroy', then the
corresponding ping sequence will be stopped."
::= { fcPingEntry 14 }
-- Ping Statistics
fcPingStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcPingStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ping statistics.
The statistics corresponding to the entries
in the fcPingTable. When an entry is deleted
in the fcPingTable, the corresponding entry
in this table is deleted automatically by
the agent."
::= { fcPingStats 1 }
fcPingStatsEntry OBJECT-TYPE
SYNTAX FcPingStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A ping statistics entry.
An entry shall be created automatically in this
table whenever a ping request is activated in the
fcPingTable by setting the fcPingRowStatus to
'active'. This entry shall have the same indices
as the entry that got activated in the fcPingTable.
An entry in this table shall be deleted by the
agent automatically either when the corresponding
entry in the fcPingTable is deleted by the
management station or is aged out by the agent.
This table shall be empty if there is no 'active'
entry in the fcPingTable."
INDEX { fcPingIndex }
::= { fcPingStatsTable 1 }
FcPingStatsEntry ::= SEQUENCE {
fcPingTxPackets Gauge32,
fcPingRxPackets Gauge32,
fcPingMinRtt Integer32,
fcPingAvgRtt Integer32,
fcPingMaxRtt Integer32,
fcPingNumTimeouts Gauge32
}
fcPingTxPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping packets sent to the target in
this sequence."
::= { fcPingStatsEntry 1 }
fcPingRxPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping packets received from the target
in this sequence."
::= { fcPingStatsEntry 2 }
fcPingMinRtt OBJECT-TYPE
SYNTAX Integer32 (0..10000000)
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum round trip time of all the packets that
have been sent in this sequence."
::= { fcPingStatsEntry 3 }
fcPingAvgRtt OBJECT-TYPE
SYNTAX Integer32 (0..10000000)
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip time of all the packets that
have been sent in this sequence."
::= { fcPingStatsEntry 4 }
fcPingMaxRtt OBJECT-TYPE
SYNTAX Integer32 (0..10000000)
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum round trip time of all the packets that
have been sent in this sequence."
::= { fcPingStatsEntry 5 }
fcPingNumTimeouts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of timeouts encountered in this sequence."
::= { fcPingStatsEntry 6 }
-- Notifications
fcPingCompletionNotify NOTIFICATION-TYPE
OBJECTS {fcPingAddress, fcPingTxPackets, fcPingRxPackets}
STATUS current
DESCRIPTION
"This notification is generated whenever a sequence
of pings is complete and the corresponding instance
of fcPingTrapOnCompletion object has been set to
'true'."
::= { fcPingNotifications 1 }
-- Conformance
fcPingMIBCompliances OBJECT IDENTIFIER ::= { fcPingMIBConformance 1 }
fcPingMIBGroups OBJECT IDENTIFIER ::= { fcPingMIBConformance 2 }
fcPingMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which
implement the Fibre Channel Ping module."
MODULE MANDATORY-GROUPS {fcPingConfigGroup,
fcPingStatsGroup,
fcPingNotifyGroup}
OBJECT fcPingRowStatus
SYNTAX INTEGER {
active(1),
createAndGo(4),
destroy(6)}
MIN-ACCESS read-create
DESCRIPTION
"Only three values 'createAndGo', 'destroy' and
'active' out of the six enumerated values need to be
supported."
::= { fcPingMIBCompliances 1 }
-- Units of conformance
fcPingConfigGroup OBJECT-GROUP
OBJECTS {fcPingVsanIndex,
fcPingAddressType,
fcPingAddress,
fcPingPacketCount,
fcPingPayloadSize,
fcPingPacketTimeout,
fcPingDelay,
fcPingAgeInterval,
fcPingUsrPriority,
fcPingAdminStatus,
fcPingOperStatus,
fcPingTrapOnCompletion,
fcPingRowStatus}
STATUS current
DESCRIPTION
"A collection of objects for configuring
Fibre Channel Ping."
::= { fcPingMIBGroups 1 }
fcPingStatsGroup OBJECT-GROUP
OBJECTS {fcPingTxPackets,
fcPingRxPackets,
fcPingMinRtt,
fcPingAvgRtt,
fcPingMaxRtt,
fcPingNumTimeouts}
STATUS current
DESCRIPTION
"A collection of objects for displaying
Fibre Channel Ping statistics."
::= { fcPingMIBGroups 2 }
fcPingNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS {fcPingCompletionNotify}
STATUS current
DESCRIPTION
"A collection of notification(s) for monitoring
Fibre Channel Ping completion."
::= { fcPingMIBGroups 3 }
END