mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-17 16:03:04 +00:00
661 lines
21 KiB
Plaintext
661 lines
21 KiB
Plaintext
-- *****************************************************************
|
|
-- CISCO-BSC-MIB.my: Binary Synchronous MIB file
|
|
--
|
|
-- Mar 1995, Sandy Logie
|
|
--
|
|
-- Copyright (c) 1995-1997, 2004 by cisco Systems, Inc.
|
|
-- Prepared by Metaplex
|
|
-- All rights reserved.
|
|
--
|
|
|
|
|
|
CISCO-BSC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
ifIndex
|
|
FROM IF-MIB
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoBscMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200408250000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W. Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
E-mail: cs-bisync@cisco.com"
|
|
DESCRIPTION
|
|
"The MIB module for BSC.
|
|
|
|
Overview of BSC MIB
|
|
|
|
MIB description
|
|
|
|
The BSC MIB provides the configuration and operational information
|
|
on Cisco's Binary Synchronous Communications implementation. The
|
|
following entities are managed:
|
|
1) BSC ports (serial interfaces)
|
|
2) BSC Control Units (stations on a port)
|
|
|
|
The BSC ports are identified by the interface index, and additional
|
|
information about this interface can be obtained from the Cisco
|
|
Serial Interface MIB.
|
|
The BSC Control Units are identified by the Control Unit address;
|
|
this is the address used by BSTUN to route the BSC traffic - it is
|
|
therefore equivalent to the bstunRouteStationAddress in the
|
|
bstunRouteTable MIB.
|
|
"
|
|
REVISION "200408250000Z"
|
|
DESCRIPTION
|
|
"Added 'generic' value to the bscPortRole object for
|
|
BSC generic support."
|
|
|
|
REVISION "9701250000Z"
|
|
DESCRIPTION
|
|
"Added support for BSTUN over Frame-relay,
|
|
Extended address and 3780 dial-in."
|
|
|
|
REVISION "9508210000Z"
|
|
DESCRIPTION
|
|
"Minor cleanups to pacify mib compiler."
|
|
::= { ciscoMgmt 36 }
|
|
|
|
bscObjects OBJECT IDENTIFIER ::= { ciscoBscMIB 1}
|
|
bscPorts OBJECT IDENTIFIER ::= { bscObjects 1}
|
|
bscControlUnits OBJECT IDENTIFIER ::= { bscObjects 2}
|
|
bscExtAddresses OBJECT IDENTIFIER ::= { bscObjects 3}
|
|
|
|
-- *********************************************************************
|
|
-- * Bsc Port Table
|
|
-- *********************************************************************
|
|
|
|
bscPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BscPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of port (serial interfaces) which have been configured
|
|
to support a BSC BSTUN group."
|
|
::= { bscPorts 1 }
|
|
|
|
bscPortEntry OBJECT-TYPE
|
|
SYNTAX BscPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status and parameter values for a port."
|
|
INDEX { ifIndex }
|
|
::= { bscPortTable 1 }
|
|
|
|
BscPortEntry ::=
|
|
SEQUENCE {
|
|
bscPortRole
|
|
INTEGER,
|
|
bscPortCodeSet
|
|
INTEGER,
|
|
bscPortPause
|
|
INTEGER,
|
|
bscPortServlim
|
|
INTEGER,
|
|
bscPortPollTimeout
|
|
INTEGER,
|
|
bscPortRecoveryRetries
|
|
INTEGER,
|
|
bscPortUnknownControlUnitsReceived
|
|
Counter32,
|
|
bscPortSoftErrors
|
|
Counter32,
|
|
bscPortHardErrors
|
|
Counter32,
|
|
bscPortProtocolViolations
|
|
Counter32,
|
|
bscPortHostTimeout
|
|
Integer32,
|
|
bscPortSpecPoll
|
|
TruthValue,
|
|
bscPortVirtualAddress
|
|
Integer32,
|
|
bscPortContentionDialTimeout
|
|
Integer32
|
|
}
|
|
|
|
bscPortRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary(1),
|
|
secondary(2),
|
|
contention(3),
|
|
dialContention(4),
|
|
generic(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The router's DLC role to the attached node.
|
|
If the bscPortRole is primary, this implies that
|
|
the port is connected to a remote secondary device.
|
|
If the role is generic, this indicates that the port
|
|
will be running framed bisynchronous frames with an unknown
|
|
protocol. If this object does not have the value 'contention'
|
|
then bscPortVirtualAddress will not be instantiated.
|
|
If this object does not have the value 'dialContention'
|
|
then bscPortContentionDialTimeout will not be instantiated."
|
|
::= { bscPortEntry 1 }
|
|
|
|
|
|
bscPortCodeSet OBJECT-TYPE
|
|
SYNTAX INTEGER { ebcdic(1), ascii(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The code set used for the line controls."
|
|
::= { bscPortEntry 2 }
|
|
|
|
bscPortPause OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For primary, it is the minimum time to be taken
|
|
for a cycle round the active poll table; if this
|
|
time has not elapsed when the bottom of the poll
|
|
table is reached, then polling will pause until
|
|
this timer expires. A value of zero means there
|
|
will be no pause between cycles round the poll
|
|
table.
|
|
For secondary, the pause time out is the delay
|
|
taken before sending a response to a poll
|
|
when it has no data frame to send.
|
|
The units are tenths of a second. The default
|
|
is 10 (1 second)."
|
|
::= { bscPortEntry 3 }
|
|
|
|
bscPortServlim OBJECT-TYPE
|
|
SYNTAX INTEGER (1..50)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is valid for primary only. It is
|
|
the number of times the active poll table will
|
|
be cycled before a non-responding control unit
|
|
will be polled. The default is 3."
|
|
::= { bscPortEntry 4 }
|
|
|
|
bscPortPollTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is valid for primary only. It is
|
|
the time that the primary will wait for a response
|
|
to a poll or select. The units are tenths of a second.
|
|
The default is 10 (1 second)."
|
|
::= { bscPortEntry 5 }
|
|
|
|
bscPortRecoveryRetries OBJECT-TYPE
|
|
SYNTAX INTEGER (1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the number of times that a recovery sequence
|
|
will be retried before the connection is considered
|
|
to have failed. The default is 5."
|
|
::= { bscPortEntry 6 }
|
|
|
|
|
|
bscPortUnknownControlUnitsReceived OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of frames received from the serial
|
|
interface with an unsupported control unit
|
|
address. If this value is non-zero it indicates
|
|
a problem in the configuration."
|
|
::= { bscPortEntry 7 }
|
|
|
|
|
|
bscPortSoftErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of soft errors; these are errors
|
|
which have been recovered. This includes
|
|
CRC errors received, frames which were
|
|
retransmitted for any reason (NAK received
|
|
or the wrong ACK received), etc. This count
|
|
is a measure of the quality of the port/line,
|
|
but should be considered in relation to the
|
|
amount of traffic on the port (frames
|
|
or bytes sent and received).
|
|
This count includes all control unit soft
|
|
errors on this port, plus errors which were
|
|
not for a specific control unit."
|
|
::= { bscPortEntry 8 }
|
|
|
|
bscPortHardErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of hard errors; these are errors which
|
|
have not been recovered after bscPortRecoveryRetries
|
|
number of retries, and therefore the connection
|
|
has been terminated.
|
|
These errors could be caused by a hardware error
|
|
in the line or in the remote device; or possibly
|
|
the bscPortRecoveryRetries value is set too low
|
|
for the quality of the line.
|
|
This count includes all control unit hard
|
|
errors on this port, plus errors which were
|
|
not for a specific control unit."
|
|
::= { bscPortEntry 9 }
|
|
|
|
bscPortProtocolViolations OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of protocol violations. This counter is
|
|
incremented when an unexpected BSC Data Link Control
|
|
character is received from the remote device; that
|
|
is, the control character is invalid in the current
|
|
state of the local BSC FSM.
|
|
This indicates that there is an incompatibility
|
|
between the two implementations of the BSC protocol.
|
|
This count includes all control unit protocol violations
|
|
on this port, plus errors which were not for a specific
|
|
control unit."
|
|
::= { bscPortEntry 10 }
|
|
|
|
bscPortHostTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (30..3000)
|
|
UNITS "deciseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is valid for interfaces configured secondary
|
|
which additionally are running local-acknowledgement. If the
|
|
configuration does not match the value will be shown as zero.
|
|
It is the time the interface will wait for a poll from the
|
|
host before putting the CU on the inactive list.
|
|
The default is 60 seconds."
|
|
::= { bscPortEntry 11 }
|
|
|
|
bscPortSpecPoll OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is valid for primary, local-acknowledgement
|
|
interfaces only. It is set to TRUE when the interface is
|
|
configured to treat specific polls as general polls.
|
|
If the configuration cannot support this value, it will be
|
|
set to FALSE.
|
|
The default is FALSE."
|
|
::= { bscPortEntry 12 }
|
|
|
|
bscPortVirtualAddress OBJECT-TYPE
|
|
SYNTAX Integer32 (1..254)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is valid for contention only. It is
|
|
the address to be used for this interface when the
|
|
remote peer router is being used as a concentrator.
|
|
The default is 01."
|
|
::= { bscPortEntry 13 }
|
|
|
|
bscPortContentionDialTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (2..30)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is valid for dialContention only. It is
|
|
the amount of time an interface can be quiescent before
|
|
return the interface to the dial-in pool.
|
|
The default is 5 seconds."
|
|
::= { bscPortEntry 14 }
|
|
|
|
-- *********************************************************************
|
|
-- * Control Unit Table
|
|
-- *********************************************************************
|
|
|
|
bscControlUnitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BscCUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about specific
|
|
Control Units."
|
|
::= { bscControlUnits 1 }
|
|
|
|
bscCUEntry OBJECT-TYPE
|
|
SYNTAX BscCUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The information regarding a single Control Unit."
|
|
INDEX { ifIndex, bscCUAddress }
|
|
::= { bscControlUnitTable 1 }
|
|
|
|
|
|
BscCUEntry ::=
|
|
SEQUENCE {
|
|
bscCUAddress
|
|
INTEGER,
|
|
bscCUState
|
|
INTEGER,
|
|
bscCUBytesSent
|
|
Counter32,
|
|
bscCUBytesReceived
|
|
Counter32,
|
|
bscCUTotalFramesSent
|
|
Counter32,
|
|
bscCUTotalFramesReceived
|
|
Counter32,
|
|
bscCUDataFramesSent
|
|
Counter32,
|
|
bscCUDataFramesReceived
|
|
Counter32,
|
|
bscCUSoftErrors
|
|
Counter32,
|
|
bscCUHardErrors
|
|
Counter32,
|
|
bscCUProtocolViolations
|
|
Counter32
|
|
}
|
|
|
|
|
|
bscCUAddress OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is the poll address of the
|
|
BSC Control Unit. This address must be unique
|
|
within a BSTUN Group."
|
|
::= { bscCUEntry 1 }
|
|
|
|
bscCUState OBJECT-TYPE
|
|
SYNTAX INTEGER { inactive(1), active(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of the BSC Control Unit; when active this indicates that
|
|
the remote Control Unit is polling or responding to polls."
|
|
::= { bscCUEntry 2 }
|
|
|
|
bscCUBytesSent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of sent bytes (octets).
|
|
Includes all control characters."
|
|
::= { bscCUEntry 3 }
|
|
|
|
|
|
bscCUBytesReceived OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of received bytes (octets).
|
|
Includes all control characters."
|
|
::= { bscCUEntry 4 }
|
|
|
|
|
|
bscCUTotalFramesSent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of sent frames (blocks).
|
|
Includes all control frames."
|
|
::= { bscCUEntry 5 }
|
|
|
|
|
|
bscCUTotalFramesReceived OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of received frames (blocks).
|
|
Includes all control frames."
|
|
::= { bscCUEntry 6 }
|
|
|
|
bscCUDataFramesSent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of sent data frames (blocks)."
|
|
::= { bscCUEntry 7 }
|
|
|
|
|
|
bscCUDataFramesReceived OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of received data frames (blocks)."
|
|
::= { bscCUEntry 8 }
|
|
|
|
bscCUSoftErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of soft errors; these are errors
|
|
which have been recovered. This includes
|
|
CRC errors received, frames which were
|
|
retransmitted for any reason (NAK received
|
|
or the wrong ACK received), etc. This count
|
|
is a measure of the quality of the connection,
|
|
but should be considered in relation to the
|
|
amount of traffic on the connection (frames
|
|
or bytes sent and received)."
|
|
::= { bscCUEntry 9 }
|
|
|
|
bscCUHardErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of hard errors; these are errors which
|
|
have not been recovered after bscPortRecoveryRetries
|
|
number of retries, and therefore the connection
|
|
has been terminated.
|
|
These errors could be caused by a hardware error
|
|
in the link or in the remote device; or possibly
|
|
the bscPortRecoveryRetries value is set too low
|
|
for the quality of the connection."
|
|
::= { bscCUEntry 10 }
|
|
|
|
bscCUProtocolViolations OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of protocol violations. This counter is
|
|
incremented when an unexpected BSC Data Link Control
|
|
character is received from the remote device; that
|
|
is, the control character is invalid in the current
|
|
state of the local BSC FSM.
|
|
This indicates that there is an incompatibility
|
|
between the two implementations of the BSC protocol."
|
|
::= { bscCUEntry 11 }
|
|
|
|
-- *********************************************************************
|
|
-- * extended Addresses
|
|
-- *********************************************************************
|
|
|
|
bscExtAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BscExtAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of all addresses configured by the bsc
|
|
extended-address command. This applies only to interfaces
|
|
with an ifType of 'bsc'. The address entries must be
|
|
unique per interface."
|
|
::= { bscExtAddresses 1 }
|
|
|
|
bscExtAddressEntry OBJECT-TYPE
|
|
SYNTAX BscExtAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The information regarding a single extended addresses."
|
|
INDEX { ifIndex , bscExtPollAddress }
|
|
::= { bscExtAddressTable 1 }
|
|
|
|
BscExtAddressEntry ::=
|
|
SEQUENCE {
|
|
bscExtPollAddress
|
|
Integer32,
|
|
bscExtSelectAddress
|
|
Integer32
|
|
}
|
|
|
|
bscExtPollAddress OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The poll address of the station configured by the
|
|
bsc extended-address command."
|
|
::= { bscExtAddressEntry 1 }
|
|
|
|
bscExtSelectAddress OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The select address of the station configured by the
|
|
bsc extended-address command."
|
|
::= { bscExtAddressEntry 2 }
|
|
|
|
-- *************************************************************************
|
|
-- * Conformance Information
|
|
-- *************************************************************************
|
|
|
|
bscMibConformance OBJECT IDENTIFIER ::= { ciscoBscMIB 3 }
|
|
bscMibCompliances OBJECT IDENTIFIER ::= { bscMibConformance 1 }
|
|
bscMibGroups OBJECT IDENTIFIER ::= { bscMibConformance 2 }
|
|
--
|
|
-- *************************************************************************
|
|
-- * Compliance Statements
|
|
-- *************************************************************************
|
|
bscMibCompliance MODULE-COMPLIANCE
|
|
STATUS obsolete -- superceded by bscMibComplianceRev1
|
|
DESCRIPTION
|
|
"The compliance statement for BSTUN."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
bscPortsGroup,
|
|
bscControlUnitsGroup
|
|
}
|
|
::= { bscMibCompliances 1 }
|
|
|
|
bscMibComplianceRev1 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for all Cisco Systems that
|
|
implement BSC functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
bscPortsGroupRev1,
|
|
bscControlUnitsGroup,
|
|
bscExtAddressGroup
|
|
}
|
|
::= { bscMibCompliances 2 }
|
|
|
|
bscPortsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
bscPortRole,
|
|
bscPortCodeSet,
|
|
bscPortPause,
|
|
bscPortServlim,
|
|
bscPortPollTimeout,
|
|
bscPortRecoveryRetries,
|
|
bscPortUnknownControlUnitsReceived,
|
|
bscPortSoftErrors,
|
|
bscPortHardErrors,
|
|
bscPortProtocolViolations
|
|
}
|
|
STATUS obsolete -- superceded by bscPortsGroupRev1
|
|
DESCRIPTION
|
|
"A collection of objects providing information about
|
|
BSC enabled interfaces."
|
|
::= { bscMibGroups 1}
|
|
|
|
bscControlUnitsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
bscCUState,
|
|
bscCUBytesSent,
|
|
bscCUBytesReceived,
|
|
bscCUTotalFramesSent,
|
|
bscCUTotalFramesReceived,
|
|
bscCUDataFramesSent,
|
|
bscCUDataFramesReceived,
|
|
bscCUSoftErrors,
|
|
bscCUHardErrors,
|
|
bscCUProtocolViolations
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about
|
|
BSC Control Units ."
|
|
::= { bscMibGroups 2 }
|
|
|
|
bscPortsGroupRev1 OBJECT-GROUP
|
|
OBJECTS {
|
|
bscPortRole,
|
|
bscPortCodeSet,
|
|
bscPortPause,
|
|
bscPortServlim,
|
|
bscPortPollTimeout,
|
|
bscPortRecoveryRetries,
|
|
bscPortUnknownControlUnitsReceived,
|
|
bscPortSoftErrors,
|
|
bscPortHardErrors,
|
|
bscPortProtocolViolations,
|
|
bscPortHostTimeout,
|
|
bscPortSpecPoll,
|
|
bscPortVirtualAddress,
|
|
bscPortContentionDialTimeout
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about
|
|
BSC enabled interfaces."
|
|
::= { bscMibGroups 3}
|
|
|
|
bscExtAddressGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
bscExtSelectAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information about
|
|
BSC extended addresses."
|
|
::= { bscMibGroups 4}
|
|
|
|
END
|