Cisco90Series-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, Counter, TimeTicks
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
TRAP-TYPE
|
|
FROM RFC-1215;
|
|
|
|
-- From RFC-1213 (MIB-II)
|
|
DisplayString ::=
|
|
OCTET STRING
|
|
|
|
ciscoTelesend OBJECT IDENTIFIER ::= { enterprises 1570 }
|
|
frMux OBJECT IDENTIFIER ::= { ciscoTelesend 1 }
|
|
|
|
-- Frame Relay Multiplexer MIB groups
|
|
-- system group
|
|
frxSys OBJECT IDENTIFIER ::= { frMux 1 }
|
|
|
|
-- defaults group
|
|
frxDefault OBJECT IDENTIFIER ::= { frMux 2 }
|
|
|
|
-- bank group
|
|
frxBank OBJECT IDENTIFIER ::= { frMux 3 }
|
|
|
|
-- channel unit group
|
|
frxChUnit OBJECT IDENTIFIER ::= { frMux 4 }
|
|
|
|
-- channel unit management group
|
|
frxMgt OBJECT IDENTIFIER ::= { frMux 5 }
|
|
|
|
-- port group
|
|
frxPort OBJECT IDENTIFIER ::= { frMux 6 }
|
|
|
|
-- frxSys group
|
|
frxSysDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Cisco 90 Series System."
|
|
::= { frxSys 1 }
|
|
|
|
frxClockHour OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Synchronized 24 hour clock for the Cisco 90 Series system -
|
|
Hour. This clock is used by the channel units
|
|
and BRITE cards to set the performance monitoring
|
|
end-of-hour and end-of-day intervals."
|
|
::= { frxSys 2 }
|
|
|
|
frxClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Synchronized 24 hour clock for the Cisco 90 Series system -
|
|
Minutes. This clock is used by the channel units
|
|
and BRITE cards to set the performance monitoring
|
|
end-of-hour and end-of-day intervals."
|
|
::= { frxSys 3 }
|
|
|
|
frxClockSec OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Synchronized 24 hour clock for the Cisco 90 Series system -
|
|
Seconds. This clock is used by the channel units
|
|
and BRITE cards to set the performance monitoring
|
|
end-of-hour and end-of-day intervals."
|
|
::= { frxSys 4 }
|
|
|
|
frxUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time since the agent was last initialized in
|
|
0.01 second increments."
|
|
::= { frxSys 5 }
|
|
|
|
frxAdminContact OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Cisco 90 Series administrative contact name."
|
|
::= { frxSys 6 }
|
|
|
|
frxSysName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Administratively assigned name for this Cisco 90 Series agent."
|
|
::= { frxSys 7 }
|
|
|
|
frxSysLoc OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Physical location of the Cisco 90 Series agent."
|
|
::= { frxSys 8 }
|
|
|
|
frxSysVersion OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Cisco 90 Series Agent version number. The version number is
|
|
an INTEGER representation of the actual version number string.
|
|
The way to translate to a version number string is 200 = 2.0.0,
|
|
201 = 2.0.1, etc."
|
|
::= { frxSys 9 }
|
|
|
|
frxUPerfTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enableUPerfTrap(1),
|
|
disableUPerfTrap(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"1=Enable sending the frxUPerfTrap trap to the
|
|
SNMP manager when a performance monitoring
|
|
threshold is crossed at an Cisco 90 Series channel unit or
|
|
a downstream BRITE card.
|
|
2=Disable Trap."
|
|
::= { frxSys 10 }
|
|
|
|
frxAgtLinkErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Annex-D signaling link reliability errors
|
|
between the Cisco 90 Series Agent and the Frame Relay Switch.
|
|
A signaling reliability error is declared whenever
|
|
the Cisco 90 Series Agent did not receive a reply from the
|
|
frame relay switch in response to an Annex-D link
|
|
integrity poll or full status inquiry poll"
|
|
::= { frxSys 11 }
|
|
|
|
frxAgtProtErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Annex-D signaling protocol errors
|
|
between the Cisco 90 Series Agent and the Frame
|
|
Relay Switch. A signaling protocol error is
|
|
declared whenever the Cisco 90 Series Agent
|
|
receives a reply with incorrect format or
|
|
sequence numbers from the frame relay switch in
|
|
response to an Annex-D link integrity poll or
|
|
full status inquiry poll"
|
|
::= { frxSys 12 }
|
|
|
|
frxAgtChInactive OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of times the Cisco 90 Series Agent Annex-D signaling
|
|
channel was declared inactive."
|
|
::= { frxSys 13 }
|
|
|
|
frxAgtChStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(1),
|
|
inactive(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current status of the Annex-D signaling channel
|
|
between the Cisco 90 Series Agent and the Frame Relay Switch."
|
|
::= { frxSys 14 }
|
|
|
|
-- frxDefault group
|
|
frxDefaultEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enableAutoLoad(1),
|
|
disableAutoLoad(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"1=Enable automatic loading of defaults (defined
|
|
in this group) to the channel unit when the
|
|
Download Configuration pushbutton on the channel
|
|
unit faceplate is pushed. 2=Disable loading."
|
|
::= { frxDefault 1 }
|
|
|
|
frxDefaultTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enableConfigureTrap(1),
|
|
disableConfigureTrap(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"1=Enable sending the frxDownloadTrap trap to
|
|
the SNMP manager when the Download Configuration
|
|
pushbutton on the channel unit faceplate is pushed.
|
|
2=Disable Trap"
|
|
::= { frxDefault 2 }
|
|
|
|
frxDConfigSrc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
annexD(1),
|
|
snmp(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System default for frxConfigSrc - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
1=Data rate and protocol set by Annex-D assignment rules.
|
|
2=Data rate and protocol set by the SNMP variables
|
|
frxPortSpeed and frxPortProtocol"
|
|
::= { frxDefault 3 }
|
|
|
|
frxDMgtT391 OBJECT-TYPE
|
|
SYNTAX INTEGER (5..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxMgtT391 - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
This controls how often (in seconds) the channel units
|
|
send an Annex-D poll to the frame relay switch.
|
|
This is the Annex-D T391 parameter (Typical value 10)"
|
|
::= { frxDefault 4 }
|
|
|
|
frxDMgtT392 OBJECT-TYPE
|
|
SYNTAX INTEGER (5..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxMgtT392 - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
This controls how long (in seconds) the channel unit
|
|
will wait for a subscriber to send it an Annex-D poll
|
|
before declaring a link error from the subscriber.
|
|
This is the Annex-D T392 parameter (Typical value 15)"
|
|
::= { frxDefault 5 }
|
|
|
|
|
|
frxDMgtN391 OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxMgtN391 - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
This controls how often the channel units send a full
|
|
status inquiry poll to the frame relay switch instead of
|
|
a link integrity verification poll.
|
|
This is the Annex-D N391 parameter (Typical value 6)"
|
|
::= { frxDefault 6 }
|
|
|
|
frxDMgtN392 OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxMgtN392 - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
When more than frxMgtN392 errors are detected in any
|
|
frxMgtN393 monitored Annex-D events, the network is
|
|
declared inactive.
|
|
This is the Annex-D N392 parameter (Typical value 3)"
|
|
::= { frxDefault 7 }
|
|
|
|
|
|
frxDMgtN393 OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxMgtN393 - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
When more than frxMgtN392 errors are detected in any
|
|
frxMgtN393 monitored Annex-D events, the network is
|
|
declared inactive.
|
|
This is the Annex-D N393 parameter (Typical value 4)"
|
|
::= { frxDefault 8 }
|
|
|
|
frxDPortSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
use56kbps(1),
|
|
use64kbps(2),
|
|
use128kbps(3),
|
|
use144kbps(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxPortSpeed - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
This is the speed that the channel unit port runs at.
|
|
1=56kbps 2=64kbps 3=128kbps 4=144kbps"
|
|
::= { frxDefault 9 }
|
|
|
|
|
|
frxDPortProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
frameRelay(1),
|
|
ppp(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxPortProtocol - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
1=Port uses Frame Relay protocol
|
|
2=Port uses PPP protocol - do RFC-1973 encapsulation"
|
|
::= { frxDefault 10 }
|
|
|
|
frxDCktCIR OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1544000)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxCktCIR - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
This is the committed information rate (CIR) in bits per
|
|
second. (Typical value 1536000/#ports)"
|
|
::= { frxDefault 11 }
|
|
|
|
frxDCktBc OBJECT-TYPE
|
|
SYNTAX INTEGER (0..16777215)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxCktBc - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
This is the committed BurstSize (Bc) in bits. The time
|
|
interval over which the burst is measured is Bc/CIR.
|
|
(Typically set to same number as frxDCktCIR)."
|
|
::= { frxDefault 12 }
|
|
|
|
frxDCktBe OBJECT-TYPE
|
|
SYNTAX INTEGER (0..16777212)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Default for frxCktBe - used when the
|
|
Download Configuration pushbutton on the channel unit
|
|
faceplate is pushed and when frxDefaultEnable is set to 1.
|
|
This is the excess BurstSize (Be) in bits. The time
|
|
interval over which the excess burst is measured is Be/CIR.
|
|
(Typical value 1536000)."
|
|
::= { frxDefault 13 }
|
|
|
|
-- frxBank group
|
|
-- frxBank Table
|
|
frxBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This Cisco 90 Series Bank Di-group Table contains channel
|
|
bank level information for each of the channel bank di-groups
|
|
in the system. A di-group is a T1 interface to the frame
|
|
relay network. The table is indexed using the Cisco 90 Series
|
|
channel bank digroup number"
|
|
::= { frxBank 1 }
|
|
|
|
frxBankEntry OBJECT-TYPE
|
|
SYNTAX FrxBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the Cisco 90 Series Bank Di-group
|
|
Table. There is one entry for each channel bank di-group
|
|
(T1) in the system. There are no entries for unused banks"
|
|
INDEX {
|
|
frxBankIndex
|
|
}
|
|
::= { frxBankTable 1 }
|
|
|
|
FrxBankEntry ::= SEQUENCE {
|
|
frxBankIndex INTEGER,
|
|
frxBankType INTEGER
|
|
}
|
|
|
|
frxBankIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (16..1007)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Channel Bank Di-group Number. This index is used to address
|
|
the various channel banks in the system. This number is the
|
|
same as the DLCI number used to communicate with the bank at
|
|
the Cisco 90 SNMP Agent. (note that this is NOT the same
|
|
as the DLCI number at the channel bank. The channel bank
|
|
always uses DLCI 30 or 31 to communicate with the Agent.)"
|
|
::= { frxBankEntry 1 }
|
|
|
|
frxBankType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
d4(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the type of channel bank and is for future use.
|
|
D4 banks return a value of 1."
|
|
::= { frxBankEntry 2 }
|
|
|
|
|
|
-- frxChUnit group
|
|
-- frxChUnit Table
|
|
|
|
frxChUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxChUEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This Cisco 90 Series Channel Unit Table contains channel unit
|
|
level control and statistics for each of the Cisco 90 Series
|
|
channel units in the system. The table is indexed
|
|
first using the Cisco 90 Series channel bank digroup number,
|
|
then the channel unit number (1 to 24)."
|
|
::= { frxChUnit 1 }
|
|
|
|
frxChUEntry OBJECT-TYPE
|
|
SYNTAX FrxChUEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the Cisco 90 Series Channel Unit Table.
|
|
There is one entry for each Cisco 90 Series channel unit in
|
|
the system. There are no entries for unused banks or empty
|
|
channel unit slots"
|
|
INDEX {
|
|
frxBankIndex,
|
|
frxChUIndex
|
|
}
|
|
::= { frxChUTable 1 }
|
|
|
|
FrxChUEntry ::= SEQUENCE {
|
|
frxChUIndex INTEGER,
|
|
frxChUType INTEGER,
|
|
frxChUVersion INTEGER,
|
|
frxSigProtocol INTEGER,
|
|
frxConfigSrc INTEGER,
|
|
frxDLCIAdLen INTEGER,
|
|
frxNetInOctets Counter,
|
|
frxNetOutOctets Counter,
|
|
frxNetBadFrames Counter,
|
|
frxNetHDLCEs Counter,
|
|
frxNetCRCEs Counter,
|
|
frxNetLinkEs Counter,
|
|
frxNetFrShEs Counter,
|
|
frxNetFrLgEs Counter,
|
|
frxNetPPPEs Counter,
|
|
frxNetBufEs Counter
|
|
}
|
|
|
|
frxChUIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Channel Unit Number. This index is used to address a
|
|
specific channel unit in a bank. For D4 channel banks
|
|
this number is the same as the physical slot number 1-24"
|
|
::= { frxChUEntry 1 }
|
|
|
|
frxChUType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cisco90i(100)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of Cisco 90 Series channel unit installed."
|
|
::= { frxChUEntry 2 }
|
|
|
|
frxChUVersion OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Cisco 90 Series channel unit version number."
|
|
::= { frxChUEntry 3 }
|
|
|
|
frxSigProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
annexD(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the type of Local In-channel Signaling used
|
|
when the subscriber is running frame relay protocol.
|
|
It is provided for future use. Set to 1 for T1.617
|
|
Annex-D"
|
|
::= { frxChUEntry 4 }
|
|
|
|
frxConfigSrc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
annexD(1),
|
|
snmp(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Source for configuring speed and protocol for each port.
|
|
1=Data rate and protocol set by DLCI assignment rules
|
|
as reported by Annex-D. This option allows control
|
|
of these basic parameters from the frame relay switch
|
|
management station instead of the Cisco 90 Series
|
|
management station.
|
|
2=Data rate and protocol set by SNMP variables
|
|
frxPortSpeed and frxPortProtocol"
|
|
::= { frxChUEntry 5 }
|
|
|
|
frxDLCIAdLen OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
twoOctetDlci(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of bytes used for the DLCI address.
|
|
For future use. 1=two octets."
|
|
::= { frxChUEntry 6 }
|
|
|
|
frxNetInOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of octets received by this channel
|
|
unit from Frame Relay Switch (on the T1 interface)
|
|
Only frames whose DLCI is addressed to a port on
|
|
this channel unit are counted. Bad frames, Annex-D
|
|
and SNMP frames are not counted. CRC bytes are not
|
|
counted"
|
|
::= { frxChUEntry 7 }
|
|
|
|
frxNetOutOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of octets transmitted to the Frame
|
|
Relay Switch (on the T1 interface) by this channel
|
|
unit. Annex-D and SNMP frames are not counted. CRC
|
|
bytes are not counted"
|
|
::= { frxChUEntry 8 }
|
|
|
|
frxNetBadFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of frames received on the network (T1)
|
|
interface that are discarded by this channel unit.
|
|
Possible reasons for discard are:
|
|
Frame contained HDLC abort (7 or more ones in a row)
|
|
Frame had a CRC error
|
|
Frame had a non-integral number of bytes
|
|
Frame was too short (less than 5 bytes)
|
|
Frame was too long (more than 8192 bytes)
|
|
Frame had bad RFC-1973 (PPP) header - this error only
|
|
occurs if destination port is set for PPP protocol.
|
|
Frame was discarded due to lack of buffer space.
|
|
Only frames whose DLCI is addressed to a port on
|
|
this channel unit are counted."
|
|
::= { frxChUEntry 9 }
|
|
|
|
frxNetHDLCEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Network Errored Seconds caused by HDLC aborts (7 or more
|
|
ones in a row). Total number of seconds in which a frame
|
|
with an HDLC abort is received by this channel unit on
|
|
the network (T1) interface. Only frames whose DLCI is
|
|
addressed to a port on this channel unit are counted."
|
|
::= { frxChUEntry 10 }
|
|
|
|
frxNetCRCEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Network Errored Seconds caused by CRC errors.
|
|
Total number of seconds in which a frame with a CRC
|
|
error is received by this channel unit on the network
|
|
(T1) interface. Only frames whose DLCI is addressed
|
|
to a port on this channel unit are counted."
|
|
::= { frxChUEntry 11 }
|
|
|
|
frxNetLinkEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Network Errored Seconds caused by Non-integral Bytes.
|
|
Total number of seconds in which a frame with a non-integral
|
|
number of bytes is received by this channel unit on the
|
|
network (T1) interface. Only frames whose DLCI is addressed
|
|
to a port on this channel unit are counted."
|
|
::= { frxChUEntry 12 }
|
|
|
|
frxNetFrShEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Network Errored Seconds caused by Short Frames received.
|
|
Total number of seconds in which a frame that is too
|
|
short (less than 5 bytes) is received by this channel
|
|
unit on the network (T1) interface. Only frames whose
|
|
DLCI is addressed to a port on this channel unit are
|
|
counted."
|
|
::= { frxChUEntry 13 }
|
|
|
|
frxNetFrLgEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Network Errored Seconds caused by Long Frames received.
|
|
Total number of seconds in which a frame that is too
|
|
long (more than 8192 bytes) is received by this channel
|
|
unit on the network (T1) interface. Only frames whose
|
|
DLCI is addressed to a port on this channel unit are
|
|
counted."
|
|
::= { frxChUEntry 14 }
|
|
|
|
frxNetPPPEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored seconds caused by bad RFC-1973 (PPP) header.
|
|
Total number of seconds in which a frame with an
|
|
invalid RFC-1973 (PPP) header is received by this
|
|
channel unit on the network (T1) interface. Only frames
|
|
whose DLCI is addressed to a port that is set to PPP
|
|
protocol and is on this channel unit are counted."
|
|
::= { frxChUEntry 15 }
|
|
|
|
frxNetBufEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds caused by Buffer Overflow.
|
|
Total number of seconds in which a frame received
|
|
by this channel unit on the network (T1) interface
|
|
was discarded due to insufficient buffer space. Only
|
|
frames whose DLCI is addressed to a port on this
|
|
channel unit are counted."
|
|
::= { frxChUEntry 16 }
|
|
|
|
-- frxMgt group
|
|
-- frxMgt Table
|
|
frxMgtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxMgtEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table monitors and controls the T1-617 Annex-D
|
|
parameters used by the channel units. There is one
|
|
table row for every channel unit in every bank. The
|
|
table is indexed first using the Cisco 90 Series channel
|
|
bank digroup number, then the channel unit number (1 to 24).
|
|
For best performance, all of the channel units in a
|
|
given bank should be set to identical values. These
|
|
values are typically set using global parameters in the
|
|
frxDefaultTable instead of directly via this table. "
|
|
::= { frxMgt 1 }
|
|
|
|
frxMgtEntry OBJECT-TYPE
|
|
SYNTAX FrxMgtEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the Cisco 90 Series Management Table.
|
|
There is one entry for each Cisco 90 Series channel unit
|
|
in the system. There are no entries for unused banks or
|
|
empty channel unit slots"
|
|
INDEX {
|
|
frxBankIndex,
|
|
frxChUIndex
|
|
}
|
|
::= { frxMgtTable 1 }
|
|
|
|
FrxMgtEntry ::= SEQUENCE {
|
|
frxPortsInSvc INTEGER,
|
|
frxMgtT391 INTEGER,
|
|
frxMgtT392 INTEGER,
|
|
frxMgtN391 INTEGER,
|
|
frxMgtN392 INTEGER,
|
|
frxMgtN393 INTEGER,
|
|
frxNetLinkErrors Counter,
|
|
frxNetProtErrors Counter,
|
|
frxNetChInactive Counter,
|
|
frxNetChStatus INTEGER
|
|
}
|
|
|
|
frxPortsInSvc OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ports in service. The number of ports on a Cisco 90 Series
|
|
channel unit that have one or more active PVCs, as determined
|
|
by Annex-D."
|
|
::= { frxMgtEntry 1 }
|
|
|
|
frxMgtT391 OBJECT-TYPE
|
|
SYNTAX INTEGER (5..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This controls how often (in seconds) the channel unit
|
|
sends an Annex-D poll to the frame relay switch.
|
|
This is the Annex-D T391 parameter (Typical value 10)"
|
|
::= { frxMgtEntry 2 }
|
|
|
|
frxMgtT392 OBJECT-TYPE
|
|
SYNTAX INTEGER (5..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This controls how long (in seconds) the channel unit
|
|
will wait for a subscriber to send it an Annex-D poll
|
|
before declaring a link error from the subscriber.
|
|
This is the Annex-D T392 parameter (Typical value 15)"
|
|
::= { frxMgtEntry 3 }
|
|
|
|
frxMgtN391 OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This controls how often (in polls) the channel unit
|
|
sends a full status inquiry poll to the frame relay
|
|
switch instead of a link integrity verification poll.
|
|
This is the Annex-D N391 parameter (Typical value 6)"
|
|
::= { frxMgtEntry 4 }
|
|
|
|
frxMgtN392 OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When more than frxMgtN392 errors are detected in any
|
|
frxMgtN393 monitored Annex-D events, the network is
|
|
declared inactive. This is the Annex-D N392 parameter
|
|
(Typical value 3)"
|
|
::= { frxMgtEntry 5 }
|
|
|
|
frxMgtN393 OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When more than frxMgtN392 errors are detected in any
|
|
frxMgtN393 monitored Annex-D events, the network is
|
|
declared inactive. This is the Annex-D N393 parameter
|
|
(Typical value 4)"
|
|
::= { frxMgtEntry 6 }
|
|
|
|
frxNetLinkErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of signaling link reliability errors from
|
|
network. A signaling reliability error is declared
|
|
whenever the channel units did not receive a reply
|
|
from the frame relay switch to an Annex-D link
|
|
integrity poll or full status inquiry poll"
|
|
::= { frxMgtEntry 7 }
|
|
|
|
frxNetProtErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of signaling protocol errors from network.
|
|
A signaling protocol error is declared whenever
|
|
the channel units receive a reply with incorrect
|
|
format or sequence numbers from the frame relay
|
|
switch in response to an Annex-D link integrity
|
|
poll or full status inquiry poll"
|
|
::= { frxMgtEntry 8 }
|
|
|
|
frxNetChInactive OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of times network Annex-D signaling channel
|
|
was declared inactive."
|
|
::= { frxMgtEntry 9 }
|
|
|
|
frxNetChStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(1),
|
|
inactive(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current status of the Annex-D signaling channel on
|
|
the network side of the channel bank."
|
|
::= { frxMgtEntry 10 }
|
|
|
|
-- frxMgtPortTable
|
|
frxMgtPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxMgtPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table monitors the T1-617 Annex-D link
|
|
between the channel units and the subscribers.
|
|
There is one table row for every port on every
|
|
channel unit in every bank. The table is indexed
|
|
first using the channel bank digroup number, then
|
|
the channel unit number (1 to 24), and then the
|
|
port number (0 to 3)."
|
|
::= { frxMgt 2 }
|
|
|
|
frxMgtPortEntry OBJECT-TYPE
|
|
SYNTAX FrxMgtPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the Cisco 90 Series Management Port
|
|
Table. There is one entry for each port on each
|
|
Cisco 90 Series channel unit in the system. There are no
|
|
entries for unused banks or empty channel unit
|
|
slots."
|
|
INDEX {
|
|
frxBankIndex,
|
|
frxChUIndex,
|
|
frxPortIndex
|
|
}
|
|
::= { frxMgtPortTable 1 }
|
|
|
|
FrxMgtPortEntry ::= SEQUENCE {
|
|
frxPortIndex INTEGER,
|
|
frxPortLinkErrors Counter,
|
|
frxPortProtErrors Counter,
|
|
frxPortChInactive Counter
|
|
}
|
|
|
|
frxPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Which subscriber port on the channel unit is
|
|
addressed. Ports are numbered from 0 to 3.
|
|
Some channel unit types have less than 4 ports."
|
|
::= { frxMgtPortEntry 1 }
|
|
|
|
frxPortLinkErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of signaling link reliability errors from
|
|
subscriber port. A signaling reliability error is
|
|
declared whenever the channel units did not receive
|
|
an Annex-D link integrity poll or full status inquiry
|
|
poll from the subscriber port within the required time."
|
|
::= { frxMgtPortEntry 2 }
|
|
|
|
frxPortProtErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of signaling protocol errors from subscriber
|
|
port. A signaling protocol error is declared whenever
|
|
the channel units receive an Annex-D link integrity
|
|
poll or full status inquiry poll with incorrect
|
|
format or sequence numbers from the subscriber port."
|
|
::= { frxMgtPortEntry 3 }
|
|
|
|
frxPortChInactive OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of times the subscriber port Annex-D signaling
|
|
channel was declared inactive"
|
|
::= { frxMgtPortEntry 4 }
|
|
|
|
-- frxPort group
|
|
-- frxPort Table
|
|
frxPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This Cisco 90 Series Port Table contains per-port control and
|
|
statistics for each of the subscriber ports in the
|
|
system. The table is indexed first using the Cisco 90 Series
|
|
channel bank digroup number, then by the channel
|
|
unit number (1 to 24), and finally by the port
|
|
number (0-3)."
|
|
::= { frxPort 1 }
|
|
|
|
frxPortEntry OBJECT-TYPE
|
|
SYNTAX FrxPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the Cisco 90 Series Port Table. There is
|
|
one entry for each port on each Cisco 90 Series channel unit
|
|
in the system. There are no entries for unused banks or
|
|
empty channel unit slots."
|
|
INDEX {
|
|
frxBankIndex,
|
|
frxChUIndex,
|
|
frxPortIndex
|
|
}
|
|
::= { frxPortTable 1 }
|
|
|
|
FrxPortEntry ::= SEQUENCE {
|
|
frxPortSpeed INTEGER,
|
|
frxPortProtocol INTEGER,
|
|
frxDSLStatus INTEGER,
|
|
frxPVCAssigned INTEGER,
|
|
frxLastChange TimeTicks,
|
|
frxBrite INTEGER,
|
|
frxDSLInOctets Counter,
|
|
frxDSLOutOctets Counter,
|
|
frxT1InOctets Counter,
|
|
frxT1OutOctets Counter,
|
|
frxDSLBadFrames Counter,
|
|
frxDSLHDLCEs Counter,
|
|
frxDSLCRCEs Counter,
|
|
frxDSLLinkEs Counter,
|
|
frxDSLFrShEs Counter,
|
|
frxDSLFrLgEs Counter,
|
|
frxDSLDLCIEs Counter,
|
|
frxTxBuf INTEGER,
|
|
frxRxBuf INTEGER,
|
|
frxPortNetEs Counter
|
|
}
|
|
|
|
frxPortSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
use56kbps(1),
|
|
use64kbps(2),
|
|
use128kbps(3),
|
|
use144kbps(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the speed that the channel unit port runs at.
|
|
1=56kbps 2=64kbps 3=128kbps 4=144kbps
|
|
This parameter can only be changed if frxConfigSrc is
|
|
set to SNMP."
|
|
::= { frxPortEntry 1 }
|
|
|
|
frxPortProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
frameRelay(1),
|
|
ppp(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter controls what protocol the channel
|
|
unit should expect the subscriber to send on the port.
|
|
1=Port uses Frame Relay protocol - no encapsulation
|
|
2=Port uses PPP protocol - do RFC-1973 encapsulation
|
|
This parameter can only be changed if frxConfigSrc is
|
|
set to SNMP."
|
|
::= { frxPortEntry 2 }
|
|
|
|
frxDSLStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
loopDown(1),
|
|
dslSyncOnly(2),
|
|
loopUpInactive(3),
|
|
loopUp(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the status of the DSL loop to the subscriber.
|
|
1=Loop is down.
|
|
2=Frx card has achieved physical layer activation with
|
|
the first BRITE card or the NT1 if there are no BRITE cards.
|
|
3=Link is up but Annex-D is still inactive. The ACT bit has
|
|
been exchanged with the NT1 indicating a clear channel path
|
|
to the customer has been established. Ports running protocols
|
|
(i.e. PPP) that do not support Annex-D will never be in this
|
|
state.
|
|
4=Link is fully up. Annex-D (if appropriate) is active."
|
|
::= { frxPortEntry 3 }
|
|
|
|
frxPVCAssigned OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of PVCs assigned to Subscriber Port as determined
|
|
by Annex-D"
|
|
::= { frxPortEntry 4 }
|
|
|
|
frxLastChange OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time since DSL went in sync or lost sync in 0.01
|
|
second increments."
|
|
::= { frxPortEntry 5 }
|
|
|
|
frxBrite OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of BRITE cards downstream. BRITE cards are used
|
|
to extend the loop over subscriber loop carrier systems
|
|
and are detected via a background polling operation."
|
|
::= { frxPortEntry 6 }
|
|
|
|
frxDSLInOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of octets received from the subscriber DSL
|
|
Does not include Annex-D octets"
|
|
::= { frxPortEntry 7 }
|
|
|
|
frxDSLOutOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of octets transmitted to the subscriber DSL.
|
|
Does not include Annex-D octets"
|
|
::= { frxPortEntry 8 }
|
|
|
|
frxT1InOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of octets received from the network
|
|
directed at this subscriber port"
|
|
::= { frxPortEntry 9 }
|
|
|
|
frxT1OutOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of octets transmitted to the network
|
|
from this subscriber port"
|
|
::= { frxPortEntry 10 }
|
|
|
|
frxDSLBadFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of frames received from this subscriber port
|
|
that were discarded. Possible reasons for discard are:
|
|
Frame contained HDLC abort (7 or more ones in a row)
|
|
Frame had a CRC error
|
|
Frame had a non-integral number of bytes
|
|
Frame was too short (less than 5 bytes)
|
|
Frame was too long (more than 8192 bytes)
|
|
Frame had illegal DLCI (not 16-23)
|
|
Frame was discarded due to lack of buffer space or
|
|
due to congestion control"
|
|
::= { frxPortEntry 11 }
|
|
|
|
frxDSLHDLCEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subscriber port Errored Seconds caused by HDLC aborts
|
|
(7 or more ones in a row). Total number of seconds in
|
|
which a frame with an HDLC abort is received from this
|
|
port."
|
|
::= { frxPortEntry 12 }
|
|
|
|
frxDSLCRCEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subscriber port Errored Seconds caused by CRC errors.
|
|
Total number of seconds in which a frame with a CRC
|
|
error is received from this port."
|
|
::= { frxPortEntry 13 }
|
|
|
|
frxDSLLinkEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subscriber port Errored Seconds caused by Non-integral
|
|
Bytes. Total number of seconds in which a frame with a
|
|
non-integral number of bytes is received from this
|
|
port."
|
|
::= { frxPortEntry 14 }
|
|
|
|
frxDSLFrShEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subscriber port Errored Seconds caused by Short Frames.
|
|
received Total number of seconds in which a frame that
|
|
is too short (less than 5 bytes) is received from this
|
|
port."
|
|
::= { frxPortEntry 15 }
|
|
|
|
frxDSLFrLgEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subscriber port Errored Seconds caused by Long Frames
|
|
received. Total number of seconds in which a frame that
|
|
is too long (more than 8192 bytes) is received from this
|
|
port."
|
|
::= { frxPortEntry 16 }
|
|
|
|
frxDSLDLCIEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subscriber port Errored Seconds caused by illegal DLCI.
|
|
Total number of seconds in which a frame that has a DLCI
|
|
other than 16 to 23 (or 0) is received from this port."
|
|
::= { frxPortEntry 17 }
|
|
|
|
frxTxBuf OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of octets in the transmit buffer for this
|
|
subscriber port. This data is waiting to be sent
|
|
to the network (T1)."
|
|
::= { frxPortEntry 18 }
|
|
|
|
frxRxBuf OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of octets in the receive buffer for this
|
|
subscriber port. This data is from the network (T1)
|
|
and is waiting to be sent to the subscriber port."
|
|
::= { frxPortEntry 19 }
|
|
|
|
frxPortNetEs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of seconds in which a frame received
|
|
from the network (T1) and targeted at this subscriber
|
|
port was discarded."
|
|
::= { frxPortEntry 20 }
|
|
|
|
|
|
-- frxCircuit Table
|
|
frxCircuitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxCircuitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This Cisco 90 Series Circuit Table contains
|
|
per-virtual-circuit control and statistics for each of the
|
|
permanent virtual circuits in the system. The table is
|
|
indexed first using the Cisco 90 Series channel bank
|
|
digroup number, then by the channel unit number (1 to 24),
|
|
then by the port number (0-3) and finally by the circuit
|
|
DLCI number (16 to 23)."
|
|
::= { frxPort 2 }
|
|
|
|
frxCircuitEntry OBJECT-TYPE
|
|
SYNTAX FrxCircuitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the Cisco 90 Series Circuit Table.
|
|
There is one entry for each permanent virtual circuit
|
|
in the system. There are no entries for unused
|
|
banks or empty channel unit slots."
|
|
INDEX {
|
|
frxBankIndex,
|
|
frxChUIndex,
|
|
frxPortIndex,
|
|
frxPvcIndex
|
|
}
|
|
::= { frxCircuitTable 1 }
|
|
|
|
FrxCircuitEntry ::= SEQUENCE {
|
|
frxPvcIndex INTEGER,
|
|
frxCktCIR INTEGER,
|
|
frxCktBc INTEGER,
|
|
frxCktBe INTEGER,
|
|
frxFarEndOpStat INTEGER,
|
|
frxCktInOctets Counter,
|
|
frxCktOutOctets Counter,
|
|
frxCktInFrames Counter,
|
|
frxCktOutFrames Counter,
|
|
frxCktDiscards Counter
|
|
}
|
|
|
|
frxPvcIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (16..23)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This index is the subscriber loop DLCI number of the
|
|
permanent virtual circuit. It ranges from 16 to 23.
|
|
The corresponding network side DLCI must be assigned
|
|
in the frame relay switch and communicated to the Cisco 90
|
|
Series channel units via the Annex-D protocol before this
|
|
element can be addressed."
|
|
::= { frxCircuitEntry 1 }
|
|
|
|
frxCktCIR OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1544000)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the committed information rate (CIR) in bits
|
|
per second for the addressed permanent virtual circuit.
|
|
(Typical value 1536000/#ports)."
|
|
::= { frxCircuitEntry 2 }
|
|
|
|
frxCktBc OBJECT-TYPE
|
|
SYNTAX INTEGER (0..16777215)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the Committed Burst Size (Bc) in bits for the
|
|
addressed permanent virtual circuit. The time interval
|
|
over which the burst is measured is Bc/CIR. (Typically
|
|
set to same number as frxCktCIR)."
|
|
::= { frxCircuitEntry 3 }
|
|
|
|
frxCktBe OBJECT-TYPE
|
|
SYNTAX INTEGER (0..16777215)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the Excess Burst Size (Be) in bits for the
|
|
addressed permanent virtual circuit. The time interval
|
|
over which the excess burst is measured is Be/CIR.
|
|
(Typical value 1536000)."
|
|
::= { frxCircuitEntry 4 }
|
|
|
|
frxFarEndOpStat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(1),
|
|
inactive(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the status of the far end of the frame relay
|
|
permanent virtual circuit (through the frame relay
|
|
network) as determined by Annex-D.
|
|
1=active
|
|
2=inactive"
|
|
::= { frxCircuitEntry 5 }
|
|
|
|
frxCktInOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input octets from the subscriber port
|
|
on the addressed permanent virtual circuit. These
|
|
octets are destined for the network (T1)."
|
|
::= { frxCircuitEntry 6 }
|
|
|
|
frxCktOutOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output octets to the subscriber port
|
|
on the addressed permanent virtual circuit. These
|
|
octets were received from the network (T1)."
|
|
::= { frxCircuitEntry 7 }
|
|
|
|
frxCktInFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input frames from the subscriber port
|
|
on the addressed permanent virtual circuit. These
|
|
frames are destined for the network (T1)."
|
|
::= { frxCircuitEntry 8 }
|
|
|
|
frxCktOutFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output frames to the subscriber port
|
|
on the addressed permanent virtual circuit. These
|
|
frames were received from the network (T1)."
|
|
::= { frxCircuitEntry 9 }
|
|
|
|
frxCktDiscards OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input frames from the subscriber port
|
|
on the addressed permanent virtual circuit that were
|
|
discarded due to congestion (lack of buffer space or
|
|
congestion control."
|
|
::= { frxCircuitEntry 10 }
|
|
|
|
|
|
-- frxUEoc Table
|
|
frxUEocTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxUEocEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This Cisco 90 Series Embedded Operations Channel Table
|
|
is used to diagnose and sectionalize problems with the
|
|
subscriber loop. It contains one entry for each of the
|
|
Cisco 90 Series channel units in the system. The table
|
|
is indexed first using the Cisco 90 Series channel bank
|
|
digroup number, then the channel unit number (1 to 24)."
|
|
::= { frxPort 3 }
|
|
|
|
frxUEocEntry OBJECT-TYPE
|
|
SYNTAX FrxUEocEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the Cisco 90 Series Embedded Operations
|
|
Channel Table. There is one entry for each Cisco 90 Series
|
|
channel unit in the system. There are no entries for unused
|
|
banks or empty channel unit slots"
|
|
INDEX {
|
|
frxBankIndex,
|
|
frxChUIndex
|
|
}
|
|
::= { frxUEocTable 1 }
|
|
|
|
FrxUEocEntry ::= SEQUENCE {
|
|
frxTestPort INTEGER,
|
|
frxTestType INTEGER,
|
|
frxLoopLoc INTEGER,
|
|
frxLoopCh INTEGER,
|
|
frxStartTest INTEGER,
|
|
frxBertRst INTEGER,
|
|
frxBertBE Counter,
|
|
frxBertTestTime TimeTicks,
|
|
frxTestInProg INTEGER
|
|
}
|
|
|
|
frxTestPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter indicates which subscriber port on the
|
|
channel unit to test. It has no effect until frxStartTest
|
|
is set to start the test. Only one port on a given channel
|
|
unit may be tested at a time."
|
|
::= { frxUEocEntry 1 }
|
|
|
|
frxTestType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
loopbackAndBert(1),
|
|
bertOnly(2),
|
|
sendCorruptCRC(3),
|
|
loopbackOnly(4),
|
|
localLoopAllPorts(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter indicates the type of test to perform. It
|
|
has no effect until frxStartTest is set to start the test.
|
|
1=Set up a loopback and run a PN-2047 Bit Error Rate Test.
|
|
2=Run a (straightaway) PN-2047 Bit Error Rate Test. This
|
|
test assumes a loopback has been manually set up somewhere
|
|
downstream or another test set running PN-2047 BERT is
|
|
connected downstream.
|
|
3=Send corrupted CRC on the DSL. This has no effect on the
|
|
frame relay CRC, only the out-of-band DSL CRC (used for
|
|
performance monitoring) is corrupted.
|
|
4=Set up a loopback at the specified location to loop the
|
|
frame relay or PPP data in both directions.
|
|
5=Setup a local loopback on all 4 ports. frxTestPort and
|
|
frxLoopLoc are ignored for this test."
|
|
::= { frxUEocEntry 2 }
|
|
|
|
frxLoopLoc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
localFrx(7),
|
|
briteCard1(1),
|
|
briteCard2(2),
|
|
briteCard3(3),
|
|
briteCard4(4),
|
|
briteCard5(5),
|
|
briteCard6(6),
|
|
nt1(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter indicates the location of the loopback or
|
|
the card that will send corrupt CRC. It has no effect
|
|
until frxStartTest is set to start the test. It has no
|
|
effect for a BertOnly test.
|
|
7=Local Cisco 90 Series card 8=NT1 at customer premise
|
|
1 to 6 is used to address intervening BRITE cards."
|
|
::= { frxUEocEntry 3 }
|
|
|
|
frxLoopCh OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
b1only(1),
|
|
b2only(2),
|
|
all(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter indicates which channels to use for the
|
|
loopbackOnly and localLoopAllPorts test. It has no effect
|
|
until frxStartTest is set to start the test. Note that the
|
|
loopbackAndBert test always loops all channels back.
|
|
1=B1 channel 2=B2 channel 3=All channels (includes all
|
|
B channels plus all D channels"
|
|
::= { frxUEocEntry 4 }
|
|
|
|
frxStartTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stopTest(1),
|
|
startTest(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter is used to start and stop the test.
|
|
frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should
|
|
be set up prior to starting the test.
|
|
1=stop test. 2=start test."
|
|
::= { frxUEocEntry 5 }
|
|
|
|
frxBertRst OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
resetBert(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter may be used during a LoopbackAndBert test
|
|
or a BertOnly test to reset the frxBertBE counter. It
|
|
must be returned to the normal posiion to allow errors to
|
|
be counted.
|
|
1=normal. 2=Reset BERT counter."
|
|
::= { frxUEocEntry 6 }
|
|
|
|
frxBertBE OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BERT test block errors"
|
|
::= { frxUEocEntry 7 }
|
|
|
|
frxBertTestTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BERT test time in 0.01 second increments"
|
|
::= { frxUEocEntry 8 }
|
|
|
|
frxTestInProg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testInProgress(1),
|
|
normalOperation(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Test in progress (1); Normal operation (2)"
|
|
::= { frxUEocEntry 9 }
|
|
|
|
-- frxUThr Table
|
|
frxUThrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxUThrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the U-interface Performance Monitoring
|
|
Thresholds and Alarms for each of the subscriber loops in
|
|
the system and for any BRITE cards extending those loops
|
|
(e.g. using Subscriber Loop Carrier systems) The table is
|
|
indexed first using the Cisco 90 Series channel bank digroup
|
|
number, then the channel unit number (1 to 24), then the port
|
|
number (0, 1, etc) and finally the location number (the BRITE
|
|
card number (1 to 6) or 7 for local parameters in the Cisco
|
|
90 Series card). These registers are defined by Bellcore
|
|
TR-TSY-000829."
|
|
::= { frxPort 4 }
|
|
|
|
frxUThrEntry OBJECT-TYPE
|
|
SYNTAX FrxUThrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the U-interface Performance Monitoring
|
|
Threshold table. There is one entry for each port on each
|
|
Cisco 90 Series channel unit in the system and one entry for
|
|
each BRITE card extending those ports. There are no entries
|
|
for unused banks or empty channel unit slots"
|
|
INDEX {
|
|
frxBankIndex,
|
|
frxChUIndex,
|
|
frxPortIndex,
|
|
frxPAddrIndex
|
|
}
|
|
::= { frxUThrTable 1 }
|
|
|
|
FrxUThrEntry ::= SEQUENCE {
|
|
frxPAddrIndex INTEGER,
|
|
frxChEsTh INTEGER,
|
|
frxCdEsTh INTEGER,
|
|
frxChSesTh INTEGER,
|
|
frxCdSesTh INTEGER,
|
|
frxAlertMask INTEGER,
|
|
frxThCond INTEGER
|
|
}
|
|
|
|
frxPAddrIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
localFrx(7),
|
|
briteCard1(1),
|
|
briteCard2(2),
|
|
briteCard3(3),
|
|
briteCard4(4),
|
|
briteCard5(5),
|
|
briteCard6(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the physical location where the performance
|
|
monitoring takes place. It may be set to localFrx(7)
|
|
to access and control PM values local to the Cisco 90
|
|
Series channel unit. If there are BRITE cards in the
|
|
subscriber loop between the Cisco 90 Series channel
|
|
unit and the customer, PM values contained in those
|
|
cards may be accessed using briteCard1(1) to
|
|
briteCard6(6) where briteCard1 is the card closest
|
|
to the Cisco 90 Series channel unit."
|
|
::= { frxUThrEntry 1 }
|
|
|
|
frxChEsTh OBJECT-TYPE
|
|
SYNTAX INTEGER (1..3600)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Hour Errored Seconds threshold. This
|
|
threshold is used for both the transmit and receive
|
|
directions. When errors are detected that exceed this
|
|
threshold and the corresponding bit in the frxAlertMask
|
|
register is 0, the corresponding bit in the frxThCond
|
|
register is set and a trap is generated (depending on
|
|
the state of frxUPerfTrapEnable). Factory defaut is 40.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUThrEntry 2 }
|
|
|
|
frxCdEsTh OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Day Errored Seconds threshold. This
|
|
threshold is used for both the transmit and receive
|
|
directions. When errors are detected that exceed this
|
|
threshold and the corresponding bit in the frxAlertMask
|
|
register is 0, the corresponding bit in the frxThCond
|
|
register is set and a trap is generated (depending on
|
|
the state of frxUPerfTrapEnable). Factory defaut is 100.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUThrEntry 3 }
|
|
|
|
frxChSesTh OBJECT-TYPE
|
|
SYNTAX INTEGER (1..3600)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Hour Severely Errored Seconds threshold. This
|
|
threshold is used for both the transmit and receive
|
|
directions. When errors are detected that exceed this
|
|
threshold and the corresponding bit in the frxAlertMask
|
|
register is 0, the corresponding bit in the frxThCond
|
|
register is set and a trap is generated (depending on
|
|
the state of frxUPerfTrapEnable). Factory defaut is 10.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUThrEntry 4 }
|
|
|
|
frxCdSesTh OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Day Severely Errored Seconds threshold. This
|
|
threshold is used for both the transmit and receive
|
|
directions. When errors are detected that exceed this
|
|
threshold and the corresponding bit in the frxAlertMask
|
|
register is 0, the corresponding bit in the frxThCond
|
|
register is set and a trap is generated (depending on
|
|
the state of frxUPerfTrapEnable). Factory defaut is 25.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUThrEntry 5 }
|
|
|
|
frxAlertMask OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"8-bit Alert Mask register. One bit for each threshold in
|
|
both directions. When set to 1, the corresponding threshold
|
|
crossing is ignored. When set to 0, the corresponding threshold
|
|
crossing is indicated in frxThCond and may cause a trap to be
|
|
sent depending on the state of frxUPerfTrapEnable.
|
|
1 Current Day Severely Errored Seconds Receive
|
|
2 Current Day Severely Errored Seconds Transmit
|
|
4 Current Day Errored Seconds Receive
|
|
8 Current Day Errored Seconds Receive
|
|
16 Current Hour Severely Errored Seconds Receive
|
|
32 Current Hour Severely Errored Seconds Transmit
|
|
64 Current Hour Errored Seconds Receive
|
|
128 Current Hour Errored Seconds Transmit
|
|
Transmit is data from the customer towards the network.
|
|
Receive is data from the network towards the Customer.
|
|
This register is defined by Bellcore TR-TSY-000829.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUThrEntry 6 }
|
|
|
|
frxThCond OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"8-bit Threshold Condition register. One bit for each
|
|
threshold in both directions. Set to 1 if the threshold
|
|
is exceeded and the corresponding bit in the frxAlertMask
|
|
register is set to 0. Only set to 0 by the SNMP manager.
|
|
1 Current Day Severely Errored Seconds Receive
|
|
2 Current Day Severely Errored Seconds Transmit
|
|
4 Current Day Errored Seconds Receive
|
|
8 Current Day Errored Seconds Receive
|
|
16 Current Hour Severely Errored Seconds Receive
|
|
32 Current Hour Severely Errored Seconds Transmit
|
|
64 Current Hour Errored Seconds Receive
|
|
128 Current Hour Errored Seconds Transmit
|
|
Receive is data from the customer towards the network.
|
|
Transmit is data from the network towards the Customer.
|
|
SNMP manager should reset bits to 0 after they it has been
|
|
read by issuing a set using the inverted byte read. Sets
|
|
will only reset bits where the set data is a 0. Setting
|
|
a bit to a 1 has no effect. This register is defined
|
|
by Bellcore TR-TSY-000829. In the spirit of SNMP, the bits
|
|
are inverted when read relative to that specification so
|
|
the sense of the bits is the same for sets and gets.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUThrEntry 7 }
|
|
|
|
-- frxUPerf Table
|
|
frxUPerfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrxUPerfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the U-interface Performance Monitoring
|
|
Statistics for each of the subscriber loops in the system
|
|
and for any BRITE cards extending those loops (e.g. using
|
|
Subscriber Loop Carrier systems) The table is indexed
|
|
first using the Cisco 90 Series channel bank digroup number,
|
|
then the channel unit number (1 to 24), then the port number
|
|
(0, 1, etc) and finally the location number (the BRITE card
|
|
number (1 to 6) or 7 for local parameters in the Cisco 90
|
|
Series card). These registers are defined by Bellcore
|
|
TR-TSY-000829."
|
|
::= { frxPort 5 }
|
|
|
|
frxUPerfEntry OBJECT-TYPE
|
|
SYNTAX FrxUPerfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A specific entry in the U-interface Performance Monitoring
|
|
Statistics table. There is one entry for each port on each
|
|
Cisco 90 Series channel unit in the system and one entry for
|
|
each BRITE card extending those ports. There are no entries for
|
|
unused banks or empty channel unit slots"
|
|
INDEX {
|
|
frxBankIndex,
|
|
frxChUIndex,
|
|
frxPortIndex,
|
|
frxPAddrIndex
|
|
}
|
|
::= { frxUPerfTable 1 }
|
|
|
|
FrxUPerfEntry ::= SEQUENCE {
|
|
frxResetPM INTEGER,
|
|
frxPMtype INTEGER,
|
|
frxChEsTx INTEGER,
|
|
frxChEsRx INTEGER,
|
|
frxPhEsTx INTEGER,
|
|
frxPhEsRx INTEGER,
|
|
frxH2EsTx INTEGER,
|
|
frxH2EsRx INTEGER,
|
|
frxH3EsTx INTEGER,
|
|
frxH3EsRx INTEGER,
|
|
frxH4EsTx INTEGER,
|
|
frxH4EsRx INTEGER,
|
|
frxH5EsTx INTEGER,
|
|
frxH5EsRx INTEGER,
|
|
frxH6EsTx INTEGER,
|
|
frxH6EsRx INTEGER,
|
|
frxH7EsTx INTEGER,
|
|
frxH7EsRx INTEGER,
|
|
frxH8EsTx INTEGER,
|
|
frxH8EsRx INTEGER,
|
|
frxCdEsTx INTEGER,
|
|
frxCdEsRx INTEGER,
|
|
frxPdEsTx INTEGER,
|
|
frxPdEsRx INTEGER,
|
|
frxChSesTx INTEGER,
|
|
frxChSesRx INTEGER,
|
|
frxPhSesTx INTEGER,
|
|
frxPhSesRx INTEGER,
|
|
frxCdSesTx INTEGER,
|
|
frxCdSesRx INTEGER,
|
|
frxPdSesTx INTEGER,
|
|
frxPdSesRx INTEGER,
|
|
frxChBeTx INTEGER,
|
|
frxChBeRx INTEGER,
|
|
frxPhBeTx INTEGER,
|
|
frxPhBeRx INTEGER
|
|
}
|
|
|
|
frxResetPM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
resetPM(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all of the performance monitoring statistics on the
|
|
specified Cisco 90 Series channel unit or BRITE card.
|
|
1=Normal. 2=Reset. There is no need to set this register
|
|
back to Normal after doing a reset."
|
|
::= { frxUPerfEntry 1 }
|
|
|
|
frxPMtype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
segmentedPM(1),
|
|
pathPM(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Determines if the Cisco 90 Series channel unit or the downstream
|
|
BRITE cards is doing segmented or path performance monitoring as
|
|
specified in Bellcore document TR-NWT-000397. Only segmented
|
|
performance monitoring should be used. In segmented PM, CRC
|
|
errors are counted on each segment of the loop, instead of
|
|
over the entire path. If no BRITE cards exist in the system,
|
|
there is no difference between segmented and path PM
|
|
1=Segmented. 2=Path."
|
|
::= { frxUPerfEntry 2 }
|
|
|
|
frxChEsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Hour Errored Seconds - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 3 }
|
|
|
|
frxChEsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Hour Errored Seconds - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 4 }
|
|
|
|
frxPhEsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Hour Errored Seconds - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 5 }
|
|
|
|
frxPhEsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Hour Errored Seconds - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 6 }
|
|
|
|
frxH2EsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 2 hours ago - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 7 }
|
|
|
|
frxH2EsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 2 hours ago - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 8 }
|
|
|
|
frxH3EsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 3 hours ago - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 9 }
|
|
|
|
frxH3EsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 3 hours ago - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 10 }
|
|
|
|
frxH4EsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 4 hours ago - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 11 }
|
|
|
|
frxH4EsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 4 hours ago - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 12 }
|
|
|
|
frxH5EsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 5 hours ago - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 13 }
|
|
|
|
frxH5EsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 5 hours ago - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 14 }
|
|
|
|
frxH6EsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 6 hours ago - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 15 }
|
|
|
|
frxH6EsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 6 hours ago - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 16 }
|
|
|
|
frxH7EsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 7 hours ago - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 17 }
|
|
|
|
frxH7EsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 7 hours ago - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 18 }
|
|
|
|
frxH8EsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 8 hours ago - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 19 }
|
|
|
|
frxH8EsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Errored Seconds 8 hours ago - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 20 }
|
|
|
|
frxCdEsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Day Errored Seconds - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 21 }
|
|
|
|
frxCdEsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Day Errored Seconds - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 22 }
|
|
|
|
frxPdEsTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Day Errored Seconds - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 23 }
|
|
|
|
frxPdEsRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Day Errored Seconds - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Errored Seconds are seconds in which one or more block
|
|
errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 24 }
|
|
|
|
frxChSesTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Hour Severely Errored Seconds - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Severely Errored Seconds are seconds in which three or more
|
|
block errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 25 }
|
|
|
|
frxChSesRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Hour Severely Errored Seconds - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Severely Errored Seconds are seconds in which three or more
|
|
block errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 26 }
|
|
|
|
frxPhSesTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Hour Severely Errored Seconds - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Severely Errored Seconds are seconds in which three or more
|
|
block errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address
|
|
(note: DDS loops cannot detect transmit errors)"
|
|
::= { frxUPerfEntry 27 }
|
|
|
|
frxPhSesRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Hour Severely Errored Seconds - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Severely Errored Seconds are seconds in which three or more
|
|
block errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 28 }
|
|
|
|
frxCdSesTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Day Severely Errored Seconds - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Severely Errored Seconds are seconds in which three or more
|
|
block errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 29 }
|
|
|
|
frxCdSesRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Day Severely Errored Seconds - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Severely Errored Seconds are seconds in which three or more
|
|
block errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 30 }
|
|
|
|
frxPdSesTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Day Severely Errored Seconds - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Severely Errored Seconds are seconds in which three or more
|
|
block errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 31 }
|
|
|
|
frxPdSesRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Day Severely Errored Seconds - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Severely Errored Seconds are seconds in which three or more
|
|
block errors occur. These errors are measured at the physical
|
|
link level (e.g. DSL CRC or BPV errors) and not at the
|
|
frame relay level. This register is defined by Bellcore
|
|
TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 32 }
|
|
|
|
frxChBeTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Hour Block Errors - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Block errors are 12 millisecond time periods in which a
|
|
physical link level (e.g. DSL CRC or BPV) error occurs.
|
|
These errors are not the same as frame relay level errors.
|
|
This register is defined by Bellcore TR-TSY-000829.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 33 }
|
|
|
|
frxChBeRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Hour Block Errors - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Block errors are 12 millisecond time periods in which a
|
|
physical link level (e.g. DSL CRC or BPV) error occurs.
|
|
These errors are not the same as frame relay level errors.
|
|
This register is defined by Bellcore TR-TSY-000829.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 34 }
|
|
|
|
frxPhBeTx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Hour Block Errors - Transmit direction.
|
|
Transmit is data from the network towards the customer.
|
|
Block errors are 12 millisecond time periods in which a
|
|
physical link level (e.g. DSL CRC or BPV) error occurs.
|
|
These errors are not the same as frame relay level errors.
|
|
This register is defined by Bellcore TR-TSY-000829.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 35 }
|
|
|
|
frxPhBeRx OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Previous Hour Block Errors - Receive direction.
|
|
Receive is data from the customer towards the network.
|
|
Block errors are 12 millisecond time periods in which a
|
|
physical link level (e.g. DSL CRC or BPV) error occurs.
|
|
These errors are not the same as frame relay level errors.
|
|
This register is defined by Bellcore TR-TSY-000829.
|
|
Indexed by Bank.ChannelUnit.Port.Address"
|
|
::= { frxUPerfEntry 36 }
|
|
|
|
-- frx Traps
|
|
frxDownloadTrap TRAP-TYPE
|
|
ENTERPRISE frMux
|
|
VARIABLES { frxBankIndex, frxChUIndex }
|
|
DESCRIPTION
|
|
"This trap is sent if the Download Config pushbutton
|
|
on the channel unit faceplate is pushed and frxDefaultTrap
|
|
is set to 1."
|
|
::= 1
|
|
|
|
frxUPerfTrap TRAP-TYPE
|
|
ENTERPRISE frMux
|
|
VARIABLES { frxBankIndex, frxChUIndex }
|
|
DESCRIPTION
|
|
"This trap is sent if a performance monitoring threshold
|
|
on a channel unit or a BRITE card is exceeded and the
|
|
corresponding bit in the frxAlertMask is enabled and
|
|
frxUPerfTrapEnable is enabled. The manager should read
|
|
and clear all of the threshold condition registers
|
|
for the specified channel unit to enable the trap to
|
|
be sent again."
|
|
::= 2
|
|
|
|
frxInsertChUTrap TRAP-TYPE
|
|
ENTERPRISE frMux
|
|
VARIABLES { frxBankIndex, frxChUIndex }
|
|
DESCRIPTION
|
|
"This trap is sent when the channel unit is inserted."
|
|
::= 3
|
|
|
|
frxRemoveChUTrap TRAP-TYPE
|
|
ENTERPRISE frMux
|
|
VARIABLES { frxBankIndex, frxChUIndex }
|
|
DESCRIPTION
|
|
"This trap is sent when the channel unit is removed."
|
|
::= 4
|
|
|
|
frxDConfigFailed TRAP-TYPE
|
|
ENTERPRISE frMux
|
|
VARIABLES { frxBankIndex, frxChUIndex }
|
|
DESCRIPTION
|
|
"This trap is sent if downloading configuration data
|
|
to a channel unit fails."
|
|
::= 5
|
|
|
|
END
|
|
|