HP-MCSG DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY,
NOTIFICATION-TYPE, enterprises, IpAddress, Integer32
FROM SNMPv2-SMI
DateAndTime, MacAddress, -- Remove for SNMPResearch compiles
DisplayString, TruthValue
FROM SNMPv2-TC
hpmcClusterState, hpmcClusterName,
hpmcClusterIndex, hpmcNodeName, hpmcNodeID
FROM HP-MCCLUSTER;
--
-- Object hierarchy under HP's enterprise object id
--
hp OBJECT IDENTIFIER ::= { enterprises 11 }
nm OBJECT IDENTIFIER ::= { hp 2 }
system OBJECT IDENTIFIER ::= { nm 3 }
general OBJECT IDENTIFIER ::= { system 1 }
hpmcCluster OBJECT IDENTIFIER ::= { general 6 }
hpmcTypeSpecific OBJECT IDENTIFIER ::= { hpmcCluster 3 }
hpmcSGCluster MODULE-IDENTITY
LAST-UPDATED "9606240000Z"
ORGANIZATION "Hewlett Packard Company,
General Systems Division"
CONTACT-INFO
" ACSL Support
Postal: Hewlett Packard Company
19111 Pruneridge Ave, MS4100
Cupertino, CA 95014
Tel: +1 408 447 1669
E-mail: acsl_sup@cup.hp.com"
DESCRIPTION
"This MIB module describes an HP private MIB
for the management of ServiceGuard Clusters.
The MIB is intended to support specific ServiceGuard
cluster attributes."
::= { hpmcTypeSpecific 1 }
--
-- MacAddress
-- DateAndTime - defined here for benefit of SNMP Research code which
-- does not have this built in for 12.2.0.2 release. When they are
-- available they should be removed from the MIB definitions and
-- "DateAndTime" and "MacAddress" should be added back into the
-- IMPORTS list.
--
-- DateAndTime specification:
--
-- field octets contents range
-- ===== ====== ======== =====
-- 1 1-2 year 0..65536
-- 2 3 month 1..12
-- 3 4 day 1..31
-- 4 5 hour 0..23
-- 5 6 minutes 0..59
-- 6 7 seconds 0..60
-- (use 60 for leap-second)
-- 7 8 deci-seconds 0..9
-- 8 9 direction from UTC '+' / '-'
-- 9 10 hours from UTC 0..11
-- 10 11 minutes from UTC 0..59
--
-- For example, Tuesday May 26, 1992 at 1:30:15 PM
-- EDT would be displayed as:
--
-- 1992-5-26,13:30:15.0,-4:0
--
-- Note that if only local time is known, then
-- timezone information (fields 8-10) is not
-- present."
--
-- DateAndTime ::= OCTET STRING (SIZE (8 | 11))
-- MacAddress ::= OCTET STRING (SIZE (6))
--
-- ServiceGuard Specific Information
--
-- The following groups are specific to ServiceGuard, and will
-- not exist on nodes which do not have the ServiceGuard
-- product installed.
--
--
-- The SG Cluster Information Group
--
-- This group contains cluster-wide information configured
-- for a particular instance of a service guard cluster to
-- which this node belongs.
--
hpmcSGTraps OBJECT IDENTIFIER ::= { hpmcSGCluster 0 }
hpmcSGObjects OBJECT IDENTIFIER ::= { hpmcSGCluster 1 }
hpmcSGGenInfo OBJECT IDENTIFIER ::= { hpmcSGObjects 1 }
--
-- The SG Cluster Specific Information
--
-- Information related to SG configuration is maintained as
-- a set of scalar objects. This is because a node can only
-- belong to at most a SINGLE ServiceGuard Cluster.
--
hpmcSGClusterIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the general cluster table which contains
other information about the Service Guard cluster (such
as membership and general state information)."
::= { hpmcSGGenInfo 1 }
hpmcSGClusterID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique ID assigned to this cluster configuration
by the MC/ServiceGuard configuration daemon."
::= { hpmcSGGenInfo 2 }
hpmcSGHeartbeatInterval OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval between the sending of heartbeat messages.
The value is expressed in microseconds."
::= { hpmcSGGenInfo 3 }
hpmcSGNodeTimeout OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum amount of time allowed between receipt of
heartbeats, before marking a node as down. The value
is expressed in microseconds."
::= { hpmcSGGenInfo 4 }
hpmcSGAutoStartTimeout OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of microseconds to wait for all nodes to join
the cluster when nodes are booting up."
::= { hpmcSGGenInfo 5 }
hpmcSGNetworkPollingInterval OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The frequency at which LAN cards send a message to
another LAN card in order to verify its health. The
value is expressed in microseconds."
::= { hpmcSGGenInfo 6 }
--
-- The SG Lock Table
--
-- A Service Guard cluster will have one or more volumes used
-- as a locking mechanism. This table describes the volumes
-- used for the SG cluster.
--
hpmcSGLockInfo OBJECT IDENTIFIER ::= { hpmcSGObjects 2 }
hpmcSGLockTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGLockEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the volume groups which are used
as locks for the ServiceGuard cluster."
::= { hpmcSGLockInfo 1 }
hpmcSGLockEntry OBJECT-TYPE
SYNTAX HpmcSGLockEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry providing information about a specific volume
used for locking the ServiceGuard cluster."
INDEX { hpmcSGVolumeIndex }
::= { hpmcSGLockTable 1 }
HpmcSGLockEntry ::=
SEQUENCE {
hpmcSGVolumeIndex Integer32,
hpmcSGPhysicalVolume DisplayString
}
--
-- May have tie in with Host Resources MIB in future.
--
hpmcSGVolumeIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A value which uniquely identifies this volume."
::= { hpmcSGLockEntry 1 }
hpmcSGPhysicalVolume OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device path used to access the disk device used for
locking."
::= { hpmcSGLockEntry 2 }
--
-- The SG Network Interface Table
--
-- ServiceGuard will utilize at least one network interface for
-- maintaining a heartbeat with other SG Cluster members. Other
-- network interfaces may also be monitored by SG.
--
-- In addition SG is capable of failing over from one interface
-- card to another in the event a failure is detected with a card.
-- Candidate links for failover must be on the same "BridgedNet"
-- as the failing link. A BridgedNet is the logical collection
-- of all interfaces which can communicate with each other at
-- the link layer (either by virtue of being directly connected
-- to the same media, or connected via a bridge).
--
hpmcSGIfInfo OBJECT IDENTIFIER ::= { hpmcSGObjects 3 }
hpmcSGNetTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGNetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the network interfaces in which SG
has an active interest."
::= { hpmcSGIfInfo 1 }
hpmcSGNetEntry OBJECT-TYPE
SYNTAX HpmcSGNetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry providing information about a specific network
interface of interest to the ServiceGuard cluster."
INDEX { hpmcSGNetIfIndex }
::= { hpmcSGNetTable 1 }
HpmcSGNetEntry ::=
SEQUENCE {
hpmcSGNetIfIndex Integer32,
hpmcSGNetIfName DisplayString,
hpmcSGNetBridgedNet Integer32,
hpmcSGNetIfFlags Integer32,
hpmcSGNetLastEvent Integer32,
hpmcSGNetLastEventTime DateAndTime,
hpmcSGNetIfHwPath DisplayString
}
hpmcSGNetIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index value which uniquely identifies the network
interface card to which this entry is applicable. This
index matches that in the MIB-II interface table and
in particular, ifIndex."
::= { hpmcSGNetEntry 1 }
hpmcSGNetIfName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the concise name of the network interface, which
is used in local system management operations. It may
differ from the MIB II object ifDescr, in that the
latter can contain additional information."
::= { hpmcSGNetEntry 2 }
hpmcSGNetBridgedNet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identifies the bridged network
to which this interface card is physically attached.
Interface cards sharing the same bridged network,
which are not currently active can act in a backup
capacity for others."
::= { hpmcSGNetEntry 3 }
hpmcSGNetIfFlags OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer whose value represents a bitstring. These
bit values indicate flag settings for this interface
as well as status information. Note that the MIB-II
interface group also contains status information, but
this is relative to IP (if IP is not enabled on the card,
it is marked as down). The value is determined by
summing the following:
1 - Heartbeat
2 - Primary
4 - Active
8 - HW Failure Detected
16 - Connectivity Failure Detected"
::= { hpmcSGNetEntry 4 }
hpmcSGNetLastEvent OBJECT-TYPE
SYNTAX Integer32 {
none(0),
down(1),
up(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An event code which indicates the last event which
resulted in reaching the current status of the interface."
::= { hpmcSGNetEntry 5 }
hpmcSGNetLastEventTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates at what time the event described by
hpmcSGNetLastEvent occured. A value of 0 indicates
that the time is unknown."
::= { hpmcSGNetEntry 6 }
--
-- Note: this information is contained in the Host Resources MIB,
-- and could be derived by matching the ifIndex with a Device Table
-- entry in that MIB. Possibly eliminate this entry in the event
-- that HR is available...
--
hpmcSGNetIfHwPath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the HW location of the interface card. This
information can be useful in locating the physical
position of a faulty card."
::= { hpmcSGNetEntry 7 }
--
-- The Service Guard Package Group
--
-- Location of information about the packages run by ServiceGuard.
--
hpmcSGPkgInfo OBJECT IDENTIFIER ::= { hpmcSGObjects 4 }
--
-- The SG Package Table
--
-- A Service Guard cluster will typically be running with
-- one or more "packages". These represent collections of services
-- which will receive high availability support from ServiceGuard.
--
-- The information in this table is available to all members of
-- the SG Cluster, not just the node where the package is currently
-- active.
--
hpmcSGPkgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGPkgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the packages which are currently
configured for the ServiceGuard cluster."
::= { hpmcSGPkgInfo 1 }
hpmcSGPkgEntry OBJECT-TYPE
SYNTAX HpmcSGPkgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry providing information about a specific package."
INDEX { hpmcSGPkgIndex }
::= { hpmcSGPkgTable 1 }
HpmcSGPkgEntry ::=
SEQUENCE {
hpmcSGPkgIndex Integer32,
hpmcSGPkgName DisplayString,
hpmcSGPkgDescr DisplayString,
hpmcSGPkgStatus Integer32,
hpmcSGPkgCurrNode DisplayString,
hpmcSGPkgLastEvent Integer32,
hpmcSGPkgLastEventTime DateAndTime,
hpmcSGPkgRunScriptPath DisplayString,
hpmcSGPkgHaltScriptPath DisplayString,
hpmcSGPkgRunScriptTimeout Integer32,
hpmcSGPkgHaltScriptTimeout Integer32
}
hpmcSGPkgIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index value which uniquely identifies the package.
These indices should be consistent across nodes in
the same SG Cluster. More specifically, these indices
should match the cluster-wide pkgid assigned by SG."
::= { hpmcSGPkgEntry 1 }
hpmcSGPkgName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name configured for this package."
::= { hpmcSGPkgEntry 2 }
hpmcSGPkgDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Explanatory text provided by the user to further
clarify the function of this package."
::= { hpmcSGPkgEntry 3 }
hpmcSGPkgStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This integer value is the encoding of a set of bits
which include configured flags for the package in
addition to dynamic status information. The value is
determined by summing those flags from the list below
which are applicable:
1 - Up
2 - Moving
4 - Valid package status
8 - PackageSwitchingEnabled
16 - NetSwitchingEnabled
32 - NodeFailFastEnabled
64 - SummaryLocalSwitchStatus "
::= { hpmcSGPkgEntry 4 }
hpmcSGPkgCurrNode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the node where the package is executing. This
string will be empty if the package is currently unowned."
::= { hpmcSGPkgEntry 5 }
hpmcSGPkgLastEvent OBJECT-TYPE
SYNTAX Integer32 {
none(0),
down(1),
up(2),
start(3),
halt(4),
globalswitchenable(5),
localswitchenable(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An event code which indicates the last event which
resulted in reacing the status described by
hpmcSGPkgStatus."
::= { hpmcSGPkgEntry 6 }
hpmcSGPkgLastEventTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates at what time the package entered the status
described by hpmcSGPkgStatus. A value of 0 indicates
that the time is unknown."
::= { hpmcSGPkgEntry 7 }
hpmcSGPkgRunScriptPath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the file which is invoked in order to
launch the package."
::= { hpmcSGPkgEntry 8 }
hpmcSGPkgHaltScriptPath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the file which is invoked in order to
shutdown the package. This is often the same as
the Run Script."
::= { hpmcSGPkgEntry 9 }
hpmcSGPkgRunScriptTimeout OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum amount of time allowed for the Run Script
to complete. The value is expressed in seconds."
::= { hpmcSGPkgEntry 10 }
hpmcSGPkgHaltScriptTimeout OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum amount of time allowed for the Run Script
to complete. The value is expressed in seconds."
::= { hpmcSGPkgEntry 11 }
--
-- The SG Package Dependent Subnet Table
--
-- A Service Guard package can specify subnets upon which it
-- has a dependency. In the event of the failure of this subnet
-- the package will be migrated to another node.
--
hpmcSGPkgSubnetTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGPkgSubnetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the subnets upon which this package
has a dependency."
::= { hpmcSGPkgInfo 2 }
hpmcSGPkgSubnetEntry OBJECT-TYPE
SYNTAX HpmcSGPkgSubnetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describes a single subnet dependency."
INDEX { hpmcSGPkgIndex, hpmcSGPkgSubnet }
::= { hpmcSGPkgSubnetTable 1 }
HpmcSGPkgSubnetEntry ::=
SEQUENCE {
hpmcSGPkgSubnet IpAddress,
hpmcSGPkgSubnetStatus INTEGER,
hpmcSGPkgOverrideMACAddr OCTET STRING
}
hpmcSGPkgSubnet OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Subnetwork Id on which this package has a dependency.
Service Guard will migrate the package to another host
in the event this subnetwork becomes unavailable."
::= { hpmcSGPkgSubnetEntry 1 }
hpmcSGPkgSubnetStatus OBJECT-TYPE
SYNTAX INTEGER{
unknown(0),
down(1),
up(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the service."
::= { hpmcSGPkgSubnetEntry 2 }
hpmcSGPkgOverrideMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A MAC address which will be used to override the
default MAC address on the interface card associated
with the given Subnet. In particular this will allow
DLPI applications to continue servicing clients on
the same address after failover. In the event
that no override MAC address is used, this object
shall be assigned the value 0x000000000000."
::= { hpmcSGPkgSubnetEntry 3 }
--
-- The SG Package IP Address Table
--
-- A Service Guard package can define zero or more IP addresses
-- which are "owned" by the package. Normally, when a package
-- is migrated to another node, these addresses are migrated
-- along with it. Sometimes the addresses may persist on the
-- node after a failover.
--
-- The information about Package IP addresses is currently only
-- available to the node which has that package active. Hence
-- this is a sparse table (i.e. rows only exist in this table
-- for packages active on this node).
--
hpmcSGPkgAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGPkgAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the movable IP addresses which are
usually associated with active packages on this node."
::= { hpmcSGPkgInfo 3 }
hpmcSGPkgAddrEntry OBJECT-TYPE
SYNTAX HpmcSGPkgAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describes a single address associated with a
package."
INDEX { hpmcSGPkgAddr }
::= { hpmcSGPkgAddrTable 1 }
HpmcSGPkgAddrEntry ::=
SEQUENCE {
hpmcSGPkgAddr IpAddress,
hpmcSGPkgID Integer32
}
hpmcSGPkgAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A migratable address which is currently active for
this package."
::= { hpmcSGPkgAddrEntry 1 }
hpmcSGPkgID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hpmcSGPkgIndex value for the owning package.
A value of 0 indicates no owning package."
::= { hpmcSGPkgAddrEntry 2 }
--
-- The SG Package Service Table
--
-- A Service Guard package will consist of one or more services
-- which do the actual work associated with the package. Service
-- Guard will parent and monitor the service process in addition
-- to other dependencies the package and cluster overall require.
--
-- The information about the Package services is only available
-- to the node which has that package active. Certainly information
-- such as PIDs are meaningless unless the package is active. Hence
-- this is a sparse table.
--
hpmcSGPkgSvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGPkgSvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the services or applications which
are associated with active packages on this node."
::= { hpmcSGPkgInfo 4 }
hpmcSGPkgSvcEntry OBJECT-TYPE
SYNTAX HpmcSGPkgSvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry that describes a single service associated with a
package."
INDEX { hpmcSGPkgIndex, hpmcSGPkgSvcIndex }
::= { hpmcSGPkgSvcTable 1 }
HpmcSGPkgSvcEntry ::=
SEQUENCE {
hpmcSGPkgSvcIndex Integer32,
hpmcSGPkgSvcName DisplayString,
hpmcSGPkgSvcStatus INTEGER,
hpmcSGPkgSvcFlags Integer32,
hpmcSGPkgSvcHaltTimeout Integer32,
hpmcSGPkgSvcMaxRestarts Integer32,
hpmcSGPkgSvcRestartCount Counter32
}
hpmcSGPkgSvcIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value which identifies this service in the
context of the package."
::= { hpmcSGPkgSvcEntry 1 }
hpmcSGPkgSvcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of this service."
::= { hpmcSGPkgSvcEntry 2 }
hpmcSGPkgSvcStatus OBJECT-TYPE
SYNTAX INTEGER{
unknown(0),
down(1),
up(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the service."
::= { hpmcSGPkgSvcEntry 3 }
hpmcSGPkgSvcFlags OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer whose value represents a bitstring. These
bit values indicate flag settings for this service.
Currently there is only one flag available. The
value is determined by summing the following:
8 - FailFastSwitch"
::= { hpmcSGPkgSvcEntry 4 }
hpmcSGPkgSvcHaltTimeout OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum amount of time ServiceGuard will wait
for the service to terminate during package shutdown.
The value is expressed in seconds."
::= { hpmcSGPkgSvcEntry 5 }
hpmcSGPkgSvcMaxRestarts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of times this Service may be restarted.
A value of 0 indicates that the service may not be
restarted, a value of -1 indicates no limit."
::= { hpmcSGPkgSvcEntry 6 }
hpmcSGPkgSvcRestartCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of times this service has been
restarted."
::= { hpmcSGPkgSvcEntry 7 }
--
-- The SG Package Dependent Node Table
--
-- A Service Guard package can specify an ordered list of nodes
-- that it will run on. This table represents that list for a
-- given package.
--
hpmcSGPkgNodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGPkgNodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the ordered list of nodes where
this package can run."
::= { hpmcSGPkgInfo 5 }
hpmcSGPkgNodeEntry OBJECT-TYPE
SYNTAX HpmcSGPkgNodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describes a single candidate node."
INDEX { hpmcSGPkgIndex, hpmcSGPkgNodeRank }
::= { hpmcSGPkgNodeTable 1 }
HpmcSGPkgNodeEntry ::=
SEQUENCE {
hpmcSGPkgNodeRank Integer32,
hpmcSGPkgNode Integer32,
hpmcSGPkgLocalSwitchEnable INTEGER
}
hpmcSGPkgNodeRank OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Order in which the node indicated by hpmcSGPkgNode will
be chosen for this package. Lowest number is chosen
first."
::= { hpmcSGPkgNodeEntry 1 }
hpmcSGPkgNode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of a node (within the hpmcNodeTable) that could run
this package."
::= { hpmcSGPkgNodeEntry 2 }
hpmcSGPkgLocalSwitchEnable OBJECT-TYPE
SYNTAX INTEGER{
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A binary value that represents the status of the LOCAL
switch capability for the respective package on the
particular node."
::= { hpmcSGPkgNodeEntry 3 }
--
-- The SG Package Dependent IPv6 Subnet Table
--
-- A Service Guard package can specify IPv6 subnets upon which it
-- has a dependency. In the event of the failure of this IPv6 subnet
-- the package will be migrated to another node.
--
hpmcSGPkgSubnet6Table OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGPkgSubnet6Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the IPv6 subnets upon which this package
has a dependency."
::= { hpmcSGPkgInfo 6 }
hpmcSGPkgSubnet6Entry OBJECT-TYPE
SYNTAX HpmcSGPkgSubnet6Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describes a single IPv6 subnet dependency."
INDEX { hpmcSGPkgIndex, hpmcSGPkgSubnet6 }
::= { hpmcSGPkgSubnet6Table 1 }
HpmcSGPkgSubnet6Entry ::=
SEQUENCE {
hpmcSGPkgSubnet6 OCTET STRING,
hpmcSGPkgSubnet6Status INTEGER,
hpmcSGPkgOverrideMACAddr6 OCTET STRING
}
hpmcSGPkgSubnet6 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IPv6 Subnetwork Id on which this package has a dependency.
Service Guard will migrate the package to another host
in the event this subnetwork becomes unavailable."
::= { hpmcSGPkgSubnet6Entry 1 }
hpmcSGPkgSubnet6Status OBJECT-TYPE
SYNTAX INTEGER{
unknown(0),
down(1),
up(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the IPv6 subnet."
::= { hpmcSGPkgSubnet6Entry 2 }
hpmcSGPkgOverrideMACAddr6 OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A MAC address which will be used to override the
default MAC address on the interface card associated
with the given IPv6 Subnet. In particular this will allow
DLPI applications to continue servicing clients on
the same address after failover. In the event
that no override MAC address is used, this object
shall be assigned the value 0x000000000000."
::= { hpmcSGPkgSubnet6Entry 3 }
--
-- The SG Package IPv6 Address Table
--
-- A Service Guard package can define zero or more IPv6 addresses
-- which are "owned" by the package. Normally, when a package
-- is migrated to another node, these IPv6 addresses are migrated
-- along with it. Sometimes the addresses may persist on the
-- node after a failover.
--
-- The information about Package IPv6 addresses is currently only
-- available to the node which has that package active. Hence
-- this is a sparse table (i.e. rows only exist in this table
-- for packages active on this node).
--
hpmcSGPkgAddr6Table OBJECT-TYPE
SYNTAX SEQUENCE OF HpmcSGPkgAddr6Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing the movable IPv6 addresses which are
usually associated with active packages on this node."
::= { hpmcSGPkgInfo 7 }
hpmcSGPkgAddr6Entry OBJECT-TYPE
SYNTAX HpmcSGPkgAddr6Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describes a single IPv6 address associated with a
package."
INDEX { hpmcSGPkgAddr6 }
::= { hpmcSGPkgAddr6Table 1 }
HpmcSGPkgAddr6Entry ::=
SEQUENCE {
hpmcSGPkgAddr6 DisplayString,
hpmcSGPkgID6 Integer32
}
hpmcSGPkgAddr6 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A migratable IPv6 address which is currently active for
this package."
::= { hpmcSGPkgAddr6Entry 1 }
hpmcSGPkgID6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hpmcSGPkgIndex value for the owning package.
A value of 0 indicates no owning package."
::= { hpmcSGPkgAddr6Entry 2 }
--
-- Traps
--
hpmcSGSubagentUp NOTIFICATION-TYPE
OBJECTS { hpmcClusterState, hpmcClusterName }
STATUS current
DESCRIPTION
"Sent by the subagent when it starts."
::= { hpmcSGTraps 1 }
hpmcSGReconfig NOTIFICATION-TYPE
OBJECTS { hpmcClusterIndex, hpmcClusterName }
STATUS current
DESCRIPTION
"Sent by the cluster coordinator after the cluster has
reformed."
::= { hpmcSGTraps 2 }
hpmcSGClusterUp NOTIFICATION-TYPE
OBJECTS { hpmcClusterIndex, hpmcClusterName }
STATUS current
DESCRIPTION
"Sent by any node in the cluster when clustering is
first initiated."
::= { hpmcSGTraps 3 }
hpmcSGClusterDown NOTIFICATION-TYPE
OBJECTS { hpmcClusterIndex, hpmcClusterName }
STATUS current
DESCRIPTION
"Sent by any node in the cluster when clustering is
being halted."
::= { hpmcSGTraps 4 }
hpmcSGConfigChange NOTIFICATION-TYPE
OBJECTS { hpmcClusterIndex, hpmcClusterName }
STATUS current
DESCRIPTION
"Sent when the cluster configuration is modified."
::= { hpmcSGTraps 5 }
hpmcSGPkgStart NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgIndex, hpmcNodeID, hpmcSGPkgName, hpmcNodeName, hpmcSGPkgStatus }
STATUS current
DESCRIPTION
"Sent from the coordinator of the cluster when a package
run script has been started on a cluster node."
::= { hpmcSGTraps 6 }
hpmcSGPkgUp NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgIndex, hpmcNodeID, hpmcSGPkgName, hpmcNodeName, hpmcSGPkgStatus }
STATUS current
DESCRIPTION
"Sent from the coordinator of the cluster when a package
run script has completed successfully on a cluster node."
::= { hpmcSGTraps 7 }
hpmcSGPkgHalt NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgIndex, hpmcNodeID, hpmcSGPkgName, hpmcNodeName, hpmcSGPkgStatus }
STATUS current
DESCRIPTION
"Sent from the coordinator of the cluster when a package
halt script has been started on a cluster node."
::= { hpmcSGTraps 8 }
hpmcSGPkgDown NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgIndex, hpmcSGPkgName, hpmcSGPkgStatus, hpmcSGPkgCurrNode}
STATUS current
DESCRIPTION
"Sent from the coordinator of the cluster when a package
halt script has completed on a cluster node."
::= { hpmcSGTraps 9 }
hpmcSGSvcDown NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgIndex, hpmcSGPkgSvcIndex, hpmcSGPkgName, hpmcSGPkgSvcName }
STATUS current
DESCRIPTION
"Sent when a previously active service has been brought
down on a cluster node."
::= { hpmcSGTraps 10 }
hpmcSGPkgFlags NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgIndex, hpmcSGPkgStatus, hpmcSGPkgName }
STATUS current
DESCRIPTION
"Sent from the coordinator of the cluster when a package's
global or local switch enable has been toggled."
::= { hpmcSGTraps 11 }
hpmcSGIPAddrUp NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgAddr }
STATUS current
DESCRIPTION
"Sent when ServiceGuard adds a relocatable IP address."
::= { hpmcSGTraps 12 }
hpmcSGIPAddrDown NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgAddr }
STATUS current
DESCRIPTION
"Sent when ServiceGuard removes a relocatable IP address."
::= { hpmcSGTraps 13 }
hpmcSGLocalSwitch NOTIFICATION-TYPE
OBJECTS { hpmcSGNetIfName, hpmcSGNetIfName }
STATUS current
DESCRIPTION
"Sent when ServiceGuard suucessfuly completes a local
switch from one network interface to another."
::= { hpmcSGTraps 14 }
hpmcSGSubnetUp NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgSubnet }
STATUS current
DESCRIPTION
"Sent when ServiceGuard detects that a previously disabled
subnet is now operational."
::= { hpmcSGTraps 15 }
hpmcSGSubnetDown NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgSubnet }
STATUS current
DESCRIPTION
"Sent when ServiceGuard detects that a previously
operational subnet is now down."
::= { hpmcSGTraps 16 }
hpmcSGNodeUp NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sent when a cluster node's status changes to 5(running)."
::= { hpmcSGTraps 17 }
hpmcSGNodeHalted NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sent when a cluster node is halted by a system
administrator."
::= { hpmcSGTraps 18 }
hpmcSGNodeFailed NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sent when a cluster node fails (leaves the cluster)."
::= { hpmcSGTraps 19 }
hpmcSGIPAddr6Up NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgAddr6 }
STATUS current
DESCRIPTION
"Sent when ServiceGuard adds a relocatable IPv6 address."
::= { hpmcSGTraps 20 }
hpmcSGIPAddr6Down NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgAddr6 }
STATUS current
DESCRIPTION
"Sent when ServiceGuard removes a relocatable IPv6 address."
::= { hpmcSGTraps 21 }
hpmcSGSubnet6Up NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgSubnet6 }
STATUS current
DESCRIPTION
"Sent when ServiceGuard detects that a previously disabled
IPv6 subnet is now operational."
::= { hpmcSGTraps 22 }
hpmcSGSubnet6Down NOTIFICATION-TYPE
OBJECTS { hpmcSGPkgSubnet6 }
STATUS current
DESCRIPTION
"Sent when ServiceGuard detects that a previously
operational IPv6 subnet is now down."
::= { hpmcSGTraps 23 }