snmp_mib_archive/ctrpm200.mib
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

115 lines
2.6 KiB
Plaintext
Executable File

-- SECTION 1: Top Level Definitions
CENTILLION-PORT-RING-MASTER-MONITOR-MIB DEFINITIONS ::= BEGIN
-- Centillion Token Ring Port Ring Master Monitor MIB Release 2.0.0
-- Revision 03/20/96
-- Copyright 1995-96 Bay Networks, Inc.
-- All rights reserved.
-- This Bay Networks SNMP Management Information Base Specification
-- (Specification) embodies Bay Networks' confidential and
-- proprietary intellectual property. Bay Networks retains all
-- title and ownership in the Specification, including any
-- revisions.
-- This Specification is supplied "AS IS," and Bay Networks makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
-- Imports
IMPORTS
OBJECT-TYPE
FROM RFC-1212
TimeTicks, IpAddress
FROM RFC1155-SMI
MacAddress, sysMonitor
FROM CENTILLION-ROOT-MIB;
-- SECTION 2: TR Port Ring Master Monitoring Information
portRmLastChg OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime the last time an entry in the
Port Ring master Table was added, deleted, or modified.
If the Port Ring master Table has not changed since cold/warm
start of the agent, then the value is zero."
::= { sysMonitor 2 }
portRmTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortRmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Port Ring Master Monitor Table."
::= { sysMonitor 3 }
portRmEntry OBJECT-TYPE
SYNTAX PortRmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the Port NMM Table. Entries in the table can
not be created or deleted via SNMP."
INDEX { portRmSlotNum, portRmPortNum }
::= { portRmTable 1 }
PortRmEntry ::= SEQUENCE {
portRmSlotNum
INTEGER,
portRmPortNum
INTEGER,
portRmIpAddr
IpAddress,
portRmMacAddr
MacAddress
}
portRmSlotNum OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot on which the topology message was received.
NOTE: Non-modular devices that do not have multiplt slots
should set this value to 1."
::= { portRmEntry 1 }
portRmPortNum OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port on which the RM_HELLO topology message was
received."
::= { portRmEntry 2 }
portRmIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the sender of the RM_HELLO topology
message."
::= { portRmEntry 3 }
portRmMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the sender of the RM_HELLO topology
message."
::= { portRmEntry 4 }
END