#-MIBFILE: cpqcmc.mib
|
|
|
|
CPQCMC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
DisplayString ::=
|
|
OCTET STRING
|
|
|
|
PhysAddress ::=
|
|
OCTET STRING
|
|
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
system OBJECT IDENTIFIER ::= { mib-2 1 }
|
|
sysName OBJECT IDENTIFIER ::= { system 5 }
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
sysContact OBJECT IDENTIFIER ::= { system 4 }
|
|
sysLocation OBJECT IDENTIFIER ::= { system 6 }
|
|
sysDescr OBJECT IDENTIFIER ::= { system 1 }
|
|
cpqCmc OBJECT IDENTIFIER ::= { compaq 153 }
|
|
|
|
cpqCmcMibRev OBJECT IDENTIFIER ::= { cpqCmc 1 }
|
|
|
|
cpqCmcComponent OBJECT IDENTIFIER ::= { cpqCmc 2 }
|
|
|
|
cpqCmcInterface OBJECT IDENTIFIER ::= { cpqCmcComponent 1 }
|
|
|
|
cpqCmcOsCommon OBJECT IDENTIFIER ::= { cpqCmcInterface 1 }
|
|
|
|
cpqCmcDevice OBJECT IDENTIFIER ::= { cpqCmcComponent 2 }
|
|
|
|
cpqCmcSetup OBJECT IDENTIFIER ::= { cpqCmcDevice 2 }
|
|
|
|
cpqCmcSetupConfig OBJECT IDENTIFIER ::= { cpqCmcSetup 1 }
|
|
|
|
cpqCmcSetupGeneral OBJECT IDENTIFIER ::= { cpqCmcSetupConfig 1 }
|
|
|
|
cpqCmcSetupEvents OBJECT IDENTIFIER ::= { cpqCmcSetupConfig 2 }
|
|
|
|
cpqCmcSetupTemp1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 1 }
|
|
|
|
cpqCmcSetupTemp2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 2 }
|
|
|
|
cpqCmcSetupFan1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 3 }
|
|
|
|
cpqCmcSetupFan2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 4 }
|
|
|
|
cpqCmcSetupVoltage OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 5 }
|
|
|
|
cpqCmcSetupHumidity OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 6 }
|
|
|
|
cpqCmcSetupInput1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 7 }
|
|
|
|
cpqCmcSetupInput2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 8 }
|
|
|
|
cpqCmcSetupInput3 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 9 }
|
|
|
|
cpqCmcSetupInput4 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 10 }
|
|
|
|
cpqCmcSetupLock1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 11 }
|
|
|
|
cpqCmcSetupLock2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 12 }
|
|
|
|
cpqCmcSetupSmoke OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 13 }
|
|
|
|
cpqCmcSetupShock OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 14 }
|
|
|
|
cpqCmcSetupAux1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 15 }
|
|
|
|
cpqCmcSetupAux2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 16 }
|
|
|
|
cpqCmcSetupAlarm1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 17 }
|
|
|
|
cpqCmcSetupAlarm2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 18 }
|
|
|
|
cpqCmcSetupClock OBJECT IDENTIFIER ::= { cpqCmcSetupConfig 3 }
|
|
|
|
cpqCmcSetupThreshold OBJECT IDENTIFIER ::= { cpqCmcSetup 2 }
|
|
|
|
cpqCmcTraps OBJECT IDENTIFIER ::= { cpqCmcSetup 3 }
|
|
|
|
cpqCmcValues OBJECT IDENTIFIER ::= { cpqCmcDevice 3 }
|
|
|
|
cpqCmcStatus OBJECT IDENTIFIER ::= { cpqCmcDevice 4 }
|
|
|
|
cpqCmcControl OBJECT IDENTIFIER ::= { cpqCmcDevice 5 }
|
|
|
|
cpqCmcLog OBJECT IDENTIFIER ::= { cpqCmcDevice 6 }
|
|
|
|
cpqCmcMibRevMajor OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Major Revision level.
|
|
A change in the major revision level represents a major change
|
|
in the architecture of the MIB. A change in the major revision
|
|
level may indicate a significant change in the information,
|
|
correct interpretation of data may require a MIB document
|
|
with the same major revision level."
|
|
::= { cpqCmcMibRev 1 }
|
|
|
|
|
|
cpqCmcMibRevMinor OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Minor Revision level.
|
|
A change in the minor revision level may represent some minor
|
|
additional support, no changes to any pre-existing information
|
|
has occurred."
|
|
::= { cpqCmcMibRev 2 }
|
|
|
|
|
|
cpqCmcMibCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall condition (status) of the system (rack(s)) represented by
|
|
this MIB.
|
|
(2) OK
|
|
(3) a minor problem, warning condition (yellow LED on CMC)
|
|
(4) a major problem (red LED on CMC)"
|
|
::= { cpqCmcMibRev 3 }
|
|
|
|
|
|
cpqCmcOsCommonPollFreq OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Insight Agent's polling frequency.
|
|
The frequency, in seconds, at which the Insight Agent requests
|
|
information from the device driver. A frequency of zero (0)
|
|
indicates that the Insight Agent retrieves the information upon
|
|
request of a management station, it does not poll the device
|
|
driver at a specific interval."
|
|
::= { cpqCmcOsCommon 1 }
|
|
|
|
|
|
cpqCmcDeviceCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
overloadDC(3),
|
|
fuseDC(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Condition of CMC device,
|
|
(3) an overload of the 24V DC supply to the connected accessories occurred
|
|
(4) the overload-protection (fuse) has released "
|
|
::= { cpqCmcDevice 1 }
|
|
|
|
|
|
cpqCmcsetLanguage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
english(2),
|
|
french(3),
|
|
italian(4),
|
|
german(5),
|
|
spanish(6),
|
|
dutch(7),
|
|
japanese(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Language of LCD"
|
|
::= { cpqCmcSetupGeneral 1 }
|
|
|
|
|
|
cpqCmcsetTempUnit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
celsius(2),
|
|
fahrenheit(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unit of all temperature values and thresholds, Celsius or Fahrenheit"
|
|
::= { cpqCmcSetupGeneral 2 }
|
|
|
|
|
|
cpqCmcsetAudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enableSilence(2),
|
|
disableSilence(3),
|
|
off(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Audible alarm in CMC unit:
|
|
(2): silencing with button on CMC is enabled
|
|
(3): silencing with button on CMC is disabled
|
|
(4): audible alarm is off (general).
|
|
On/off of audible alarm for each event is possible in cpqCmcsetupEvents-group"
|
|
::= { cpqCmcSetupGeneral 3 }
|
|
|
|
|
|
cpqCmcPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..6))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Password to get access to terminal or LCD"
|
|
::= { cpqCmcSetupGeneral 4 }
|
|
|
|
|
|
cpqCmcPasswordOption OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Enable or disable password entry to get access to terminal or LCD"
|
|
::= { cpqCmcSetupGeneral 5 }
|
|
|
|
|
|
cpqCmcquitRelay1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Enable or disable acknowledging currently active alarm relay 1
|
|
(with 'ENTER' on CMC)."
|
|
::= { cpqCmcSetupGeneral 6 }
|
|
|
|
|
|
cpqCmcquitRelay2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Enable or disable acknowledging currently active alarm relay 2
|
|
(with 'ENTER' on CMC)."
|
|
::= { cpqCmcSetupGeneral 7 }
|
|
|
|
|
|
cpqCmclogicRelay1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
closeAtAlarm(2),
|
|
openAtAlarm(3),
|
|
closeAtEPO(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Logic of Relay 1: (2) Relay will pick up in case of an alarm
|
|
(3) Relay will release in case of an alarm
|
|
(4) not used"
|
|
::= { cpqCmcSetupGeneral 8 }
|
|
|
|
|
|
cpqCmclogicRelay2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
closeAtAlarm(2),
|
|
openAtAlarm(3),
|
|
closeAtEPO(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Logic of Relay 2: (2) Relay will pick up in case of an alarm
|
|
(3) Relay will release in case of an alarm
|
|
(4) not used"
|
|
::= { cpqCmcSetupGeneral 9 }
|
|
|
|
|
|
cpqCmcSetupTemp1Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature sensor:
|
|
(2) sensor available
|
|
(3) sensor not available"
|
|
::= { cpqCmcSetupTemp1 1 }
|
|
|
|
|
|
cpqCmcSetupTemp1RelaysWarn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of warning condition
|
|
of temperature sensor 1:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupTemp1 2 }
|
|
|
|
|
|
cpqCmcSetupTemp1RelaysMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of max. alarm condition
|
|
of temperature sensor 1:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupTemp1 3 }
|
|
|
|
|
|
cpqCmcSetupTemp1RelaysMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of min. alarm condition
|
|
of temperature sensor 1:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupTemp1 4 }
|
|
|
|
|
|
cpqCmcSetupTemp1AudibleAlarmWarn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of warning condition
|
|
of temperature sensor 1:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupTemp1 5 }
|
|
|
|
|
|
cpqCmcSetupTemp1AudibleAlarmMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of max. alarm condition
|
|
of temperature sensor 1:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupTemp1 6 }
|
|
|
|
|
|
cpqCmcSetupTemp1AudibleAlarmMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of min. alarm condition
|
|
of temperature sensor 1:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupTemp1 7 }
|
|
|
|
|
|
cpqCmcSetupTemp2Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature sensor:
|
|
(2) sensor available
|
|
(3) sensor not available"
|
|
::= { cpqCmcSetupTemp2 1 }
|
|
|
|
|
|
cpqCmcSetupTemp2RelaysWarn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of warning condition
|
|
of temperature sensor 2:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupTemp2 2 }
|
|
|
|
|
|
cpqCmcSetupTemp2RelaysMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of max. alarm condition
|
|
of temperature sensor 2:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupTemp2 3 }
|
|
|
|
|
|
cpqCmcSetupTemp2RelaysMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of min. alarm condition
|
|
of temperature sensor 2:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupTemp2 4 }
|
|
|
|
|
|
cpqCmcSetupTemp2AudibleAlarmWarn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of warning condition
|
|
of temperature sensor 2:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupTemp2 5 }
|
|
|
|
|
|
cpqCmcSetupTemp2AudibleAlarmMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of max. alarm condition
|
|
of temperature sensor 2:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupTemp2 6 }
|
|
|
|
|
|
cpqCmcSetupTemp2AudibleAlarmMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of min. alarm condition
|
|
of temperature sensor 2:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupTemp2 7 }
|
|
|
|
|
|
cpqCmcSetupFan1Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Fan 1:
|
|
(2) Fan 1 available
|
|
(3) Fan 1 not available"
|
|
::= { cpqCmcSetupFan1 1 }
|
|
|
|
|
|
cpqCmcSetupFan1Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of alarm condition
|
|
of Fan 1:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupFan1 2 }
|
|
|
|
|
|
cpqCmcSetupFan1AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of alarm condition
|
|
of Fan 1:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupFan1 3 }
|
|
|
|
|
|
cpqCmcSetupFan2Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Fan 2:
|
|
(2) Fan 2 available
|
|
(3) Fan 2 not available"
|
|
::= { cpqCmcSetupFan2 1 }
|
|
|
|
|
|
cpqCmcSetupFan2Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of alarm condition
|
|
of Fan 2:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupFan2 2 }
|
|
|
|
|
|
cpqCmcSetupFan2AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of alarm condition
|
|
of Fan 2:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupFan2 3 }
|
|
|
|
|
|
cpqCmcSetupVoltageAvail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Voltage monitoring:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupVoltage 1 }
|
|
|
|
|
|
cpqCmcSetupVoltageRelaysMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of max. alarm condition
|
|
of voltage monitoring:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupVoltage 2 }
|
|
|
|
|
|
cpqCmcSetupVoltageRelaysMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of min. alarm condition
|
|
of voltage monitoring:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupVoltage 3 }
|
|
|
|
|
|
cpqCmcSetupVoltageAudibleAlarmMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of max. alarm condition
|
|
of voltage monitoring:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupVoltage 4 }
|
|
|
|
|
|
cpqCmcSetupVoltageAudibleAlarmMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of min. alarm condition
|
|
of voltage monitoring:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupVoltage 5 }
|
|
|
|
|
|
cpqCmcSetupHumidityAvail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidity sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupHumidity 1 }
|
|
|
|
|
|
cpqCmcSetupHumidityRelaysMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of max. alarm condition
|
|
of humidity monitoring:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupHumidity 2 }
|
|
|
|
|
|
cpqCmcSetupHumidityRelaysMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of min. alarm condition
|
|
of humidity monitoring:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupHumidity 3 }
|
|
|
|
|
|
cpqCmcSetupHumidityAudibleAlarmMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of max. alarm condition
|
|
of humidity monitoring:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupHumidity 4 }
|
|
|
|
|
|
cpqCmcSetupHumidityAudibleAlarmMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of min. alarm condition
|
|
of humidity monitoring:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupHumidity 5 }
|
|
|
|
|
|
cpqCmcSetupInput1Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1 sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupInput1 1 }
|
|
|
|
|
|
cpqCmcSetupInput1Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of a warning condition
|
|
of Input 1 (Door/Sidewall open):
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupInput1 2 }
|
|
|
|
|
|
cpqCmcSetupInput1AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of a warning condition
|
|
of Input 1 (Door/Sidewall open):
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupInput1 3 }
|
|
|
|
|
|
cpqCmcSetupInput1FansOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
both(2),
|
|
fan1(3),
|
|
fan2(4),
|
|
noFan(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Fan switching off if Door/Sidewall 1 is opened:
|
|
(2) both fans would be switched off
|
|
(3) only fan1 will be switched off
|
|
(4) only fan2 will be switched off
|
|
(5) no fan will be switched off"
|
|
::= { cpqCmcSetupInput1 4 }
|
|
|
|
|
|
cpqCmcSetupInput1ShockSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Shock sensor function if Door/Sidewall 1 is opened:
|
|
(2) Shock Sensor is off (disabled)
|
|
(3) Shock Sensor is on (enabled)"
|
|
::= { cpqCmcSetupInput1 5 }
|
|
|
|
|
|
cpqCmcSetupInput1Description OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Descriptional text of Input1"
|
|
::= { cpqCmcSetupInput1 6 }
|
|
|
|
|
|
cpqCmcSetupInput1Lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
lock1(3),
|
|
lock2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Door/Sidewall 1 is locked by:
|
|
(2) no locking device
|
|
(3) locking device 1
|
|
(4) locking device 2
|
|
(5) both locking devices"
|
|
::= { cpqCmcSetupInput1 7 }
|
|
|
|
|
|
cpqCmcSetupInput2Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 2 sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupInput2 1 }
|
|
|
|
|
|
cpqCmcSetupInput2Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of a warning condition
|
|
of Input 2 (Door/Sidewall open):
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupInput2 2 }
|
|
|
|
|
|
cpqCmcSetupInput2AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of a warning condition
|
|
of Input 2 (Door/Sidewall open):
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupInput2 3 }
|
|
|
|
|
|
cpqCmcSetupInput2FansOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
both(2),
|
|
fan1(3),
|
|
fan2(4),
|
|
noFan(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Fan switching off if Door/Sidewall 2 is opened:
|
|
(2) both fans would be switched off
|
|
(3) only fan1 will be switched off
|
|
(4) only fan2 will be switched off
|
|
(5) no fan will be switched off"
|
|
::= { cpqCmcSetupInput2 4 }
|
|
|
|
|
|
cpqCmcSetupInput2ShockSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Shock sensor function if Door/Sidewall 2 is opened:
|
|
(2) Shock Sensor is off (disabled)
|
|
(3) Shock Sensor is on (enabled)"
|
|
::= { cpqCmcSetupInput2 5 }
|
|
|
|
|
|
cpqCmcSetupInput2Description OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Descriptional text of Input2"
|
|
::= { cpqCmcSetupInput2 6 }
|
|
|
|
|
|
cpqCmcSetupInput2Lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
lock1(3),
|
|
lock2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Door/Sidewall 2 is locked by:
|
|
(2) no locking device
|
|
(3) locking device 1
|
|
(4) locking device 2
|
|
(5) both locking devices"
|
|
::= { cpqCmcSetupInput2 7 }
|
|
|
|
|
|
cpqCmcSetupInput3Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 3 sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupInput3 1 }
|
|
|
|
|
|
cpqCmcSetupInput3Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of a warning condition
|
|
of Input 3 (Door/Sidewall open):
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupInput3 2 }
|
|
|
|
|
|
cpqCmcSetupInput3AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of a warning condition
|
|
of Input 3 (Door/Sidewall open):
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupInput3 3 }
|
|
|
|
|
|
cpqCmcSetupInput3FansOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
both(2),
|
|
fan1(3),
|
|
fan2(4),
|
|
noFan(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Fan switching off if Door/Sidewall 3 is opened:
|
|
(2) both fans would be switched off
|
|
(3) only fan1 will be switched off
|
|
(4) only fan2 will be switched off
|
|
(5) no fan will be switched off"
|
|
::= { cpqCmcSetupInput3 4 }
|
|
|
|
|
|
cpqCmcSetupInput3ShockSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Shock sensor function if Door/Sidewall 3 is opened:
|
|
(2) Shock Sensor is off (disabled)
|
|
(3) Shock Sensor is on (enabled)"
|
|
::= { cpqCmcSetupInput3 5 }
|
|
|
|
|
|
cpqCmcSetupInput3Description OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Descriptional text of Input3"
|
|
::= { cpqCmcSetupInput3 6 }
|
|
|
|
|
|
cpqCmcSetupInput3Lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
lock1(3),
|
|
lock2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Door/Sidewall 3 is locked by:
|
|
(2) no locking device
|
|
(3) locking device 1
|
|
(4) locking device 2
|
|
(5) both locking devices"
|
|
::= { cpqCmcSetupInput3 7 }
|
|
|
|
|
|
cpqCmcSetupInput4Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 4 sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupInput4 1 }
|
|
|
|
|
|
cpqCmcSetupInput4Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of a warning condition
|
|
of Input 4 (Door/Sidewall open):
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupInput4 2 }
|
|
|
|
|
|
cpqCmcSetupInput4AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of a warning condition
|
|
of Input 4 (Door/Sidewall open):
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupInput4 3 }
|
|
|
|
|
|
cpqCmcSetupInput4FansOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
both(2),
|
|
fan1(3),
|
|
fan2(4),
|
|
noFan(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Fan switching off if Door/Sidewall 4 is opened:
|
|
(2) both fans would be switched off
|
|
(3) only fan1 will be switched off
|
|
(4) only fan2 will be switched off
|
|
(5) no fan will be switched off"
|
|
::= { cpqCmcSetupInput4 4 }
|
|
|
|
|
|
cpqCmcSetupInput4ShockSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Shock sensor function if Door/Sidewall 4 is opened:
|
|
(2) Shock Sensor is off (disabled)
|
|
(3) Shock Sensor is on (enabled)"
|
|
::= { cpqCmcSetupInput4 5 }
|
|
|
|
|
|
cpqCmcSetupInput4Description OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Descriptional text of Input4"
|
|
::= { cpqCmcSetupInput4 6 }
|
|
|
|
|
|
cpqCmcSetupInput4Lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
lock1(3),
|
|
lock2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Door/Sidewall 4 is locked by:
|
|
(2) no locking device
|
|
(3) locking device 1
|
|
(4) locking device 2
|
|
(5) both locking devices"
|
|
::= { cpqCmcSetupInput4 7 }
|
|
|
|
|
|
cpqCmcSetupLock1Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Door locking device 1:
|
|
(2) device available
|
|
(3) device not available, no alarm, if door is not locked"
|
|
::= { cpqCmcSetupLock1 1 }
|
|
|
|
|
|
cpqCmcSetupLock1Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Lock 1 (door not locked..):
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupLock1 2 }
|
|
|
|
|
|
cpqCmcSetupLock1RelaysDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Locking device 1 (power fail, low battery...):
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupLock1 3 }
|
|
|
|
|
|
cpqCmcSetupLock1AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Lock 1:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupLock1 4 }
|
|
|
|
|
|
cpqCmcSetupLock1AudibleAlarmDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Locking device 1 (power fail, low battery..):
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupLock1 5 }
|
|
|
|
|
|
cpqCmcSetupLock1Time OBJECT-TYPE
|
|
SYNTAX INTEGER (3..600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Time in seconds while the lock 1 is unlocked
|
|
after getting an unlock-command"
|
|
::= { cpqCmcSetupLock1 6 }
|
|
|
|
|
|
cpqCmcSetupLock1PwrFailUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
auto(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unlock door in case of power fail of locking device:
|
|
(2) disabled
|
|
(3) auto unlock the door
|
|
(4) unlock door with remote signal"
|
|
::= { cpqCmcSetupLock1 7 }
|
|
|
|
|
|
cpqCmcSetupLock1BattLowUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
auto(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unlock door in case of low battery of locking device:
|
|
(2) disabled
|
|
(3) auto unlock the door
|
|
(4) unlock door with remote signal"
|
|
::= { cpqCmcSetupLock1 8 }
|
|
|
|
|
|
cpqCmcSetupLock1NetFailUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
auto(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unlock door in case of network failure:
|
|
(2) disabled
|
|
(3) auto unlock the door
|
|
(4) unlock door with remote signal"
|
|
::= { cpqCmcSetupLock1 9 }
|
|
|
|
|
|
cpqCmcSetupLock1LifeFailUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
auto(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unlock door in case of lifecheck failure (connection CMC<->locking device):
|
|
(2) disabled
|
|
(3) auto unlock the door
|
|
(4) unlock door with remote signal"
|
|
::= { cpqCmcSetupLock1 10 }
|
|
|
|
|
|
cpqCmcSetupLock2Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Door locking device 2:
|
|
(2) device available
|
|
(3) device not available, no alarm, if door is not locked"
|
|
::= { cpqCmcSetupLock2 1 }
|
|
|
|
|
|
cpqCmcSetupLock2Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Lock 2 (door not locked..):
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupLock2 2 }
|
|
|
|
|
|
cpqCmcSetupLock2RelaysDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Locking device 2 (power fail, low battery...):
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupLock2 3 }
|
|
|
|
|
|
cpqCmcSetupLock2AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Lock 2:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupLock2 4 }
|
|
|
|
|
|
cpqCmcSetupLock2AudibleAlarmDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Locking device 2 (power fail, low battery..):
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupLock2 5 }
|
|
|
|
|
|
cpqCmcSetupLock2Time OBJECT-TYPE
|
|
SYNTAX INTEGER (3..600)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Time in seconds while the lock 2 is unlocked
|
|
after getting an unlock-command"
|
|
::= { cpqCmcSetupLock2 6 }
|
|
|
|
|
|
cpqCmcSetupLock2PwrFailUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
auto(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unlock door in case of power fail of locking device:
|
|
(2) disabled
|
|
(3) auto unlock the door
|
|
(4) unlock door with remote signal"
|
|
::= { cpqCmcSetupLock2 7 }
|
|
|
|
|
|
cpqCmcSetupLock2BattLowUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
auto(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unlock door in case of low battery of locking device:
|
|
(2) disabled
|
|
(3) auto unlock the door
|
|
(4) unlock door with remote signal"
|
|
::= { cpqCmcSetupLock2 8 }
|
|
|
|
|
|
cpqCmcSetupLock2NetFailUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
auto(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unlock door in case of network failure:
|
|
(2) disabled
|
|
(3) auto unlock the door
|
|
(4) unlock door with remote signal"
|
|
::= { cpqCmcSetupLock2 9 }
|
|
|
|
|
|
cpqCmcSetupLock2LifeFailUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disabled(2),
|
|
auto(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Unlock door in case of lifecheck failure (connection CMC<->locking device):
|
|
(2) disabled
|
|
(3) auto unlock the door
|
|
(4) unlock door with remote signal"
|
|
::= { cpqCmcSetupLock2 10 }
|
|
|
|
|
|
cpqCmcSetupSmokeAvail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Smoke sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupSmoke 1 }
|
|
|
|
|
|
cpqCmcSetupSmokeRelays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Smoke Sensor:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupSmoke 2 }
|
|
|
|
|
|
cpqCmcSetupSmokeAudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Smoke Sensor:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupSmoke 3 }
|
|
|
|
|
|
cpqCmcSetupSmokeFansOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
both(2),
|
|
fan1(3),
|
|
fan2(4),
|
|
noFan(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Fan switching off if in case of smoke-alarm:
|
|
(2) both fans would be switched off
|
|
(3) only fan1 will be switched off
|
|
(4) only fan2 will be switched off
|
|
(5) no fan will be switched off"
|
|
::= { cpqCmcSetupSmoke 4 }
|
|
|
|
|
|
cpqCmcSetupSmokeUnlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
both(2),
|
|
lock1(3),
|
|
lock2(4),
|
|
noLock(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Lock is unlocked in case of smoke-alarm:
|
|
(2) both locks will be unlocked
|
|
(3) only lock1 will be unlocked
|
|
(4) only lock2 will be unlocked
|
|
(5) no lock will be unlocked"
|
|
::= { cpqCmcSetupSmoke 5 }
|
|
|
|
|
|
cpqCmcSetupShockAvail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Shock sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupShock 1 }
|
|
|
|
|
|
cpqCmcSetupShockRelays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Shock Sensor:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupShock 2 }
|
|
|
|
|
|
cpqCmcSetupShockAudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Shock Sensor:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupShock 3 }
|
|
|
|
|
|
cpqCmcSetupShockSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Sensitivity of shock-sensor.
|
|
1 = low sensitivity, 10 = high sensitivity"
|
|
::= { cpqCmcSetupShock 4 }
|
|
|
|
|
|
cpqCmcSetupAux1Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Aux 1 sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupAux1 1 }
|
|
|
|
|
|
cpqCmcSetupAux1Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Aux 1:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupAux1 2 }
|
|
|
|
|
|
cpqCmcSetupAux1AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Aux 1:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupAux1 3 }
|
|
|
|
|
|
cpqCmcSetupAux1InputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
normOpen(2),
|
|
normClosed(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Type of other digital input (used for any digital signal):
|
|
(2) contact is normally open, no alarm if contact is open,
|
|
alarm if contact is closed
|
|
(3) contact is normally closed, no alarm if contact is closed,
|
|
alarm if contact is open"
|
|
::= { cpqCmcSetupAux1 4 }
|
|
|
|
|
|
cpqCmcSetupAux1Description OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Descriptional text of the digital input (Aux1) "
|
|
::= { cpqCmcSetupAux1 5 }
|
|
|
|
|
|
cpqCmcSetupAux1Unlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
noLock(2),
|
|
lock1(3),
|
|
lock2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Lock will be unlocked with Aux-Input 1:
|
|
(2) no lock will be unlocked
|
|
(3) only lock1 will be unlocked
|
|
(4) only lock2 will be unlocked
|
|
(5) both locks will be unlocked"
|
|
::= { cpqCmcSetupAux1 6 }
|
|
|
|
|
|
cpqCmcSetupAux2Avail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
available(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Aux 2 sensor:
|
|
(2) available
|
|
(3) not available"
|
|
::= { cpqCmcSetupAux2 1 }
|
|
|
|
|
|
cpqCmcSetupAux2Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Aux 2:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupAux2 2 }
|
|
|
|
|
|
cpqCmcSetupAux2AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Aux 2:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupAux2 3 }
|
|
|
|
|
|
cpqCmcSetupAux2InputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
normOpen(2),
|
|
normClosed(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Type of other digital input (used for any digital signal):
|
|
(2) contact is normally open, no alarm if contact is open,
|
|
alarm if contact is closed
|
|
(3) contact is normally closed, no alarm if contact is closed,
|
|
alarm if contact is open"
|
|
::= { cpqCmcSetupAux2 4 }
|
|
|
|
|
|
cpqCmcSetupAux2Description OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Descriptional text of the digital input (Aux2) "
|
|
::= { cpqCmcSetupAux2 5 }
|
|
|
|
|
|
cpqCmcSetupAux2Unlock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
noLock(2),
|
|
lock1(3),
|
|
lock2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Lock will be unlocked with Aux-Input 2:
|
|
(2) no lock will be unlocked
|
|
(3) only lock1 will be unlocked
|
|
(4) only lock2 will be unlocked
|
|
(5) both locks will be unlocked"
|
|
::= { cpqCmcSetupAux2 6 }
|
|
|
|
|
|
cpqCmcSetupAlarm1Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Alarm 1:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupAlarm1 1 }
|
|
|
|
|
|
cpqCmcSetupAlarm1AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Alarm 1:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupAlarm1 2 }
|
|
|
|
|
|
cpqCmcSetupAlarm1Description OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Descriptional text of alarm 1"
|
|
::= { cpqCmcSetupAlarm1 3 }
|
|
|
|
|
|
cpqCmcSetupAlarm2Relays OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
off(2),
|
|
relay1(3),
|
|
relay2(4),
|
|
both(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition
|
|
of Alarm 2:
|
|
(2) no switching of Relays
|
|
(3) Relay 1 will switch
|
|
(4) Relay 2 will switch
|
|
(5) both Relays will switch"
|
|
::= { cpqCmcSetupAlarm2 1 }
|
|
|
|
|
|
cpqCmcSetupAlarm2AudibleAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition
|
|
of Alarm 2:
|
|
(2) Start Audible Alarm
|
|
(3) No Audible Alarm"
|
|
::= { cpqCmcSetupAlarm2 2 }
|
|
|
|
|
|
cpqCmcSetupAlarm2Description OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Descriptional text of alarm 2"
|
|
::= { cpqCmcSetupAlarm2 3 }
|
|
|
|
|
|
cpqCmcSetupDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..10))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "actual Date in format DD.MM.YYYY"
|
|
::= { cpqCmcSetupClock 1 }
|
|
|
|
|
|
cpqCmcSetupTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59)"
|
|
::= { cpqCmcSetupClock 2 }
|
|
|
|
|
|
cpqCmcThresholdMaxTemp1 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold value maximum temperature 1"
|
|
::= { cpqCmcSetupThreshold 1 }
|
|
|
|
|
|
cpqCmcThresholdWarningTemp1 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold value warning temperature 1"
|
|
::= { cpqCmcSetupThreshold 2 }
|
|
|
|
|
|
cpqCmcThresholdMinTemp1 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold value minimum temperature 1"
|
|
::= { cpqCmcSetupThreshold 3 }
|
|
|
|
|
|
cpqCmcThresholdMaxTemp2 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold value maximum temperature 2"
|
|
::= { cpqCmcSetupThreshold 4 }
|
|
|
|
|
|
cpqCmcThresholdWarningTemp2 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold value warning temperature 2"
|
|
::= { cpqCmcSetupThreshold 5 }
|
|
|
|
|
|
cpqCmcThresholdMinTemp2 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold value minimum temperature 2"
|
|
::= { cpqCmcSetupThreshold 6 }
|
|
|
|
|
|
cpqCmcThresholdFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold Fan 1 in deg F or deg C, Fan 1 will start
|
|
if temperature 1 exceeds this value"
|
|
::= { cpqCmcSetupThreshold 7 }
|
|
|
|
|
|
cpqCmcThresholdFan1Hysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Hystersis of Fan 1, Fan 1 will stop if temperature 1 falls below
|
|
value of cpqCmcThresholdFan1 minus cpqCmcThresholdFan1Hysteresis"
|
|
::= { cpqCmcSetupThreshold 8 }
|
|
|
|
|
|
cpqCmcThresholdFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold Fan 2 in deg F or deg C, Fan 2 will start
|
|
if temperature 2 exceeds this value"
|
|
::= { cpqCmcSetupThreshold 9 }
|
|
|
|
|
|
cpqCmcThresholdFan2Hysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Hystersis of Fan 2, Fan 2 will stop if temperature 2 falls below
|
|
value of cpqCmcThresholdFan2 minus cpqCmcThresholdFan2Hysteresis"
|
|
::= { cpqCmcSetupThreshold 10 }
|
|
|
|
|
|
cpqCmcThresholdMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold high value Voltage alarm"
|
|
::= { cpqCmcSetupThreshold 11 }
|
|
|
|
|
|
cpqCmcThresholdMinVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold low value Voltage alarm"
|
|
::= { cpqCmcSetupThreshold 12 }
|
|
|
|
|
|
cpqCmcThresholdMaxHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold high value Humidity alarm"
|
|
::= { cpqCmcSetupThreshold 13 }
|
|
|
|
|
|
cpqCmcThresholdMinHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Threshold low value Humidity alarm"
|
|
::= { cpqCmcSetupThreshold 14 }
|
|
|
|
|
|
cpqCmcTrapTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of trapTable entries. The number of trap-receivers"
|
|
::= { cpqCmcTraps 1 }
|
|
|
|
|
|
cpqCmcTrapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqCmcTrapEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of trap-receiver entries"
|
|
::= { cpqCmcTraps 2 }
|
|
|
|
|
|
cpqCmcTrapEntry OBJECT-TYPE
|
|
SYNTAX CpqCmcTrapEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Entries of trapTable"
|
|
INDEX { cpqCmcTrapIndex }
|
|
|
|
::= { cpqCmcTrapTable 1 }
|
|
|
|
cpqCmcTrapEntry ::=
|
|
SEQUENCE {
|
|
cpqCmcTrapIndex INTEGER,
|
|
cpqCmcTrapStatus INTEGER,
|
|
cpqCmcTrapIPaddress DisplayString
|
|
}
|
|
|
|
cpqCmcTrapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index for the trap-receiver-table. Its value ranges between
|
|
1 and the value of cpqCmcTrapTableNumber "
|
|
::= { cpqCmcTrapEntry 1 }
|
|
|
|
|
|
cpqCmcTrapStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Enable or disable trap receiver"
|
|
::= { cpqCmcTrapEntry 2 }
|
|
|
|
|
|
cpqCmcTrapIPaddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..15))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "IP-address of trap-receiver"
|
|
::= { cpqCmcTrapEntry 3 }
|
|
|
|
|
|
cpqCmcValueTemp1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Actual temperature value of temperature sensor 1 in deg C or deg F"
|
|
::= { cpqCmcValues 1 }
|
|
|
|
|
|
cpqCmcValueTemp2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Actual temperature value of temperature sensor 2 in deg C or deg F"
|
|
::= { cpqCmcValues 2 }
|
|
|
|
|
|
cpqCmcValueVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Actual value of power supply (voltage monitoring and fans) in V"
|
|
::= { cpqCmcValues 3 }
|
|
|
|
|
|
cpqCmcValueHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Actual value of humidity
|
|
0..100%"
|
|
::= { cpqCmcValues 4 }
|
|
|
|
|
|
cpqCmcValueOperatingTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Operating time CMC-unit"
|
|
::= { cpqCmcValues 5 }
|
|
|
|
|
|
cpqCmcStatusTemp1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
normal(2),
|
|
warning(3),
|
|
overMax(4),
|
|
underMin(5),
|
|
noSensor(6),
|
|
error(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of temperature 1,
|
|
see thresholds of temperature 1:
|
|
(2) temperature normal
|
|
(3) temperature exceeds warning threshold
|
|
(4) temperature exceeds max. threshold
|
|
(5) temperature drops under min. threshold
|
|
(6) no sensor connected, not available
|
|
(7) error, sensor disconnected"
|
|
::= { cpqCmcStatus 1 }
|
|
|
|
|
|
cpqCmcStatusTemp2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
normal(2),
|
|
warning(3),
|
|
overMax(4),
|
|
underMin(5),
|
|
noSensor(6),
|
|
error(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of temperature 2,
|
|
see thresholds of temperature 2:
|
|
(2) temperature normal
|
|
(3) temperature exceeds warning threshold
|
|
(4) temperature exceeds max. threshold
|
|
(5) temperature drops under min. threshold
|
|
(6) no sensor connected, not available
|
|
(7) error, sensor disconnected"
|
|
::= { cpqCmcStatus 2 }
|
|
|
|
|
|
cpqCmcStatusFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
autoOff(2),
|
|
autoOn(3),
|
|
manualOff(4),
|
|
manualOn(5),
|
|
smokeOff(6),
|
|
doorOff(7),
|
|
noFan(8),
|
|
error(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of fan 1:
|
|
(2) fan is switched off by temperature sensor 1
|
|
(3) fan is switched on by temperature sensor 1
|
|
(4) fan is switched off by Manual Control (cpqCmcSetFan1)
|
|
(5) fan is switched on by Manual Control (cpqCmcSetFan1)
|
|
(6) fan is switched off because of smoke alarm
|
|
(7) fan is switched off because door is open
|
|
(8) no fan
|
|
(9) fan error, current monitoring"
|
|
::= { cpqCmcStatus 3 }
|
|
|
|
|
|
cpqCmcStatusFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
autoOff(2),
|
|
autoOn(3),
|
|
manualOff(4),
|
|
manualOn(5),
|
|
smokeOff(6),
|
|
doorOff(7),
|
|
noFan(8),
|
|
error(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of fan 2:
|
|
(2) fan is switched off by temperature sensor 2
|
|
(3) fan is switched on by temperature sensor 2
|
|
(4) fan is switched off by Manual Control (cpqCmcSetFan2)
|
|
(5) fan is switched on by Manual Control (cpqCmcSetFan2)
|
|
(6) fan is switched off because of smoke alarm
|
|
(7) fan is switched off because door is open
|
|
(8) no fan
|
|
(9) fan error, current monitoring"
|
|
::= { cpqCmcStatus 4 }
|
|
|
|
|
|
cpqCmcStatusVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
normal(2),
|
|
overMax(3),
|
|
underMin(4),
|
|
noVoltage(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The voltage-status,
|
|
see thresholds of power supply:
|
|
(2) voltage normal
|
|
(3) voltage exceeds max. threshold
|
|
(4) voltage drops under min. threshold
|
|
(5) no power connected"
|
|
::= { cpqCmcStatus 5 }
|
|
|
|
|
|
cpqCmcStatusHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
normal(2),
|
|
overMax(3),
|
|
underMin(4),
|
|
noSensor(5),
|
|
error(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The humidity-status,
|
|
see thresholds of humidity:
|
|
(2) humidity normal
|
|
(3) humidity exceeds max. threshold
|
|
(4) humidity drops under min. threshold
|
|
(5) no sensor connected, not available
|
|
(6) error, sensor disconnected"
|
|
::= { cpqCmcStatus 6 }
|
|
|
|
|
|
cpqCmcStatusInput1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
closed(2),
|
|
open(3),
|
|
noSensor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of door/sidepanel 1, closed (2), open (3)
|
|
or no sensor connected (4)"
|
|
::= { cpqCmcStatus 7 }
|
|
|
|
|
|
cpqCmcStatusInput2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
closed(2),
|
|
open(3),
|
|
noSensor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of door/sidepanel 2, closed (2), open (3)
|
|
or no sensor connected (4)"
|
|
::= { cpqCmcStatus 8 }
|
|
|
|
|
|
cpqCmcStatusInput3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
closed(2),
|
|
open(3),
|
|
noSensor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of door/sidepanel 3, closed (2), open (3)
|
|
or no sensor connected (4)"
|
|
::= { cpqCmcStatus 9 }
|
|
|
|
|
|
cpqCmcStatusInput4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
closed(2),
|
|
open(3),
|
|
noSensor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of door/sidepanel 4, closed (2), open (3)
|
|
or no sensor connected (4)"
|
|
::= { cpqCmcStatus 10 }
|
|
|
|
|
|
cpqCmcStatusLock1Lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
locked(2),
|
|
unlockedAuto(3),
|
|
unlockedTime(4),
|
|
unlockedSmoke(5),
|
|
unlockedKey(6),
|
|
unlockedPwrFail(7),
|
|
unlockedBattLow(8),
|
|
unlockedNetFail(9),
|
|
unlockedConnFail(10),
|
|
readyToLock(11),
|
|
alarm(12),
|
|
configError(13),
|
|
notAvail(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of door locking 1
|
|
(2) Door locking-device is activated, door is locked
|
|
(3) Door locking-device is not activated, door is unlocked by Network Management
|
|
(4) Door locking-device is not activated for x sec, time see
|
|
cpqCmcSetupLock1Time, door is unlocked by Network Management
|
|
(5) Door locking-device is not activated, door is unlocked because of Smoke alarm
|
|
(6) Door is unlocked from remote-signal
|
|
(7) Door locking-device is not activated, door is unlocked
|
|
because of Power Fail of locking device
|
|
(8) Door locking-device is not activated, door is unlocked
|
|
because of low Battery of locking device
|
|
(9) Door locking-device is not activated, door is unlocked
|
|
because of Network Fail
|
|
(10)Door locking-device is not activated, door is unlocked
|
|
because of connection fail, no connection locking device <-> CMC
|
|
(11)Door locking-device is ready to lock, lock will be activated after doors are closed
|
|
(12)Door locking-device is activated but door is not locked, alarm
|
|
(13)Configuration error, association door to locking-device missing
|
|
(14)Lock not installed"
|
|
::= { cpqCmcStatus 11 }
|
|
|
|
|
|
cpqCmcStatusLock2Lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
locked(2),
|
|
unlockedAuto(3),
|
|
unlockedTime(4),
|
|
unlockedSmoke(5),
|
|
unlockedKey(6),
|
|
unlockedPwrFail(7),
|
|
unlockedBattLow(8),
|
|
unlockedNetFail(9),
|
|
unlockedConnFail(10),
|
|
readyToLock(11),
|
|
alarm(12),
|
|
configError(13),
|
|
notAvail(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of door locking 2
|
|
(2) Door locking-device is activated, door is locked
|
|
(3) Door locking-device is not activated, door is unlocked by Network Management
|
|
(4) Door locking-device is not activated for x sec, time see
|
|
cpqCmcSetupLock1Time, door is unlocked by Network Management
|
|
(5) Door locking-device is not activated, door is unlocked because of Smoke alarm
|
|
(6) Door is unlocked from remote-signal
|
|
(7) Door locking-device is not activated, door is unlocked
|
|
because of Power Fail of locking device
|
|
(8) Door locking-device is not activated, door is unlocked
|
|
because of low Battery of locking device
|
|
(9) Door locking-device is not activated, door is unlocked
|
|
because of Network Fail
|
|
(10)Door locking-device is not activated, door is unlocked
|
|
because of connection fail, no connection locking device <-> CMC
|
|
(11)Door locking-device is ready to lock, lock will be activated after doors are closed
|
|
(12)Door locking-device is activated but door is not locked, alarm
|
|
(13)Configuration error, association door to locking-device missing
|
|
(14)Lock not installed"
|
|
::= { cpqCmcStatus 12 }
|
|
|
|
|
|
cpqCmcStatusSmoke OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
cleared(2),
|
|
present(3),
|
|
noSensor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status smoke-sensor, OK (2), smoke detected (3)
|
|
or no sensor connected (4)"
|
|
::= { cpqCmcStatus 13 }
|
|
|
|
|
|
cpqCmcStatusShock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
cleared(2),
|
|
present(3),
|
|
noSensor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status Shock sensor, OK (2), shock detected (3)
|
|
or no sensor connected (4)"
|
|
::= { cpqCmcStatus 14 }
|
|
|
|
|
|
cpqCmcStatusAux1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
alarm(3),
|
|
noSensor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status aux. digital input"
|
|
::= { cpqCmcStatus 15 }
|
|
|
|
|
|
cpqCmcStatusAux2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
alarm(3),
|
|
noSensor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status aux. digital input"
|
|
::= { cpqCmcStatus 16 }
|
|
|
|
|
|
cpqCmcStatusAlarm1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
alarm(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status of alarm 1, see cmpCmcsetAlarm1. This alarm can be set from
|
|
the Network management system. A descriptional text for this alarm
|
|
can be set in cpqCmcSetupAlarm1Description."
|
|
::= { cpqCmcStatus 17 }
|
|
|
|
|
|
cpqCmcStatusAlarm2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
alarm(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status of alarm 2, see cmpCmcsetAlarm2. This alarm can be set from
|
|
the Network management system. A descriptional text for this alarm
|
|
can be set in cpqCmcSetupAlarm2Description."
|
|
::= { cpqCmcStatus 18 }
|
|
|
|
|
|
cpqCmcStatusLock1Dev OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
powerFail(3),
|
|
lowBattery(4),
|
|
replaceBatt(5),
|
|
missingBatt(6),
|
|
noConnect(7),
|
|
notAvail(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of door-locking device 1
|
|
(2) OK
|
|
(3) Power fail of door locking-device
|
|
(4) Low Battery of door locking-device
|
|
(5) Battery of door locking device needs to be replaced
|
|
(6) Battery missing, insert all batteries
|
|
(7) Connection CMC->door locking device lost
|
|
(8) Lock not installed"
|
|
::= { cpqCmcStatus 19 }
|
|
|
|
|
|
cpqCmcStatusLock2Dev OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
powerFail(3),
|
|
lowBattery(4),
|
|
replaceBatt(5),
|
|
missingBatt(6),
|
|
noConnect(7),
|
|
notAvail(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of door-locking device 2
|
|
(2) OK
|
|
(3) Power fail of door locking-device
|
|
(4) Low Battery of door locking-device
|
|
(5) Battery of door locking device needs to be replaced
|
|
(6) Battery missing, insert all batteries
|
|
(6) Connection CMC->door locking device lost
|
|
(7) Lock not installed"
|
|
::= { cpqCmcStatus 20 }
|
|
|
|
|
|
cpqCmcStatusAccess OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status access, for future use"
|
|
::= { cpqCmcControl 1 }
|
|
|
|
|
|
cpqCmcSetLock1Lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
lockDoor(2),
|
|
openDoorTime(3),
|
|
openDoor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Set door locking device 1, see table
|
|
With this command the management-station can set the conditions for
|
|
the door locking device
|
|
(2) Door will be locked
|
|
(3) Door will be unlocked for a defined time,
|
|
time can be changed, see cpqCmcSetupLock1Time
|
|
(4) Door is generally unlocked
|
|
Locking and unlocking with this command can not be
|
|
enabled or disabled with cpqCmcSetLock1Key-command"
|
|
::= { cpqCmcControl 2 }
|
|
|
|
|
|
cpqCmcSetLock1Key OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disable(2),
|
|
enableBoth(3),
|
|
enableKeypad(4),
|
|
enableRemoteInput(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Enable or disable unlocking of the rack-door with external components
|
|
like keypad or remote input.
|
|
With this command the management station can set the conditions for
|
|
unlocking the door:
|
|
(2) unlocking is disabled, no unlocking with keypad or remote input
|
|
(3) unlocking with keypad or remote signal (both) is enabled
|
|
(4) unlocking with keypad (only) is enabled
|
|
(5) unlocking with remote input (only) is enabled
|
|
Unlocking door with the cpqCmcSetLock1Lock-command does not depend
|
|
on this variable"
|
|
::= { cpqCmcControl 3 }
|
|
|
|
|
|
cpqCmcSetLock2Lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
lockDoor(2),
|
|
openDoorTime(3),
|
|
openDoor(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Set door locking device 2, see table
|
|
With this command the management-station can set the conditions for
|
|
the door locking device
|
|
(2) Door will be locked
|
|
(3) Door will be unlocked for a defined time,
|
|
time can be changed, see cpqCmcSetupLock2Time
|
|
(4) Door is generally unlocked
|
|
Locking and unlocking with this command can not be
|
|
enabled or disabled with cpqCmcSetLock2Key-command"
|
|
::= { cpqCmcControl 4 }
|
|
|
|
|
|
cpqCmcSetLock2Key OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
disable(2),
|
|
enableBoth(3),
|
|
enableKeypad(4),
|
|
enableRemoteInput(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Enable or disable unlocking of the rack-door with external components
|
|
like keypad or remote input.
|
|
With this command the management-station can set the conditions for
|
|
unlocking the door:
|
|
(2) unlocking is disabled, no unlocking with keypad or remote input
|
|
(3) unlocking with keypad or remote signal (both) is enabled
|
|
(4) unlocking with keypad (only) is enabled
|
|
(5) unlocking with remote input (only) is enabled
|
|
Unlocking door with the cpqCmcSetDoor2-command does not depend
|
|
on this variable"
|
|
::= { cpqCmcControl 5 }
|
|
|
|
|
|
cpqCmcSetMessage OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Set message to CMC, for future use"
|
|
::= { cpqCmcControl 6 }
|
|
|
|
|
|
cpqCmcSetAlarm1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
clearAlarm(2),
|
|
setAlarm(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Is used to set an alarm in the CMC from the management-station.
|
|
With this command the management-station can i.e. switch on an
|
|
alarm-relay or the AudibleAlarm of the CMC.
|
|
Can be used for alert-handling"
|
|
::= { cpqCmcControl 7 }
|
|
|
|
|
|
cpqCmcSetAlarm2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
clearAlarm(2),
|
|
setAlarm(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Is used to set an alarm in the CMC from the management-station.
|
|
With this command the management-station can i.e. switch on an
|
|
alarm-relay or the AudibleAlarm of the CMC.
|
|
Can be used for alert-handling"
|
|
::= { cpqCmcControl 8 }
|
|
|
|
|
|
cpqCmcSetFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
auto(2),
|
|
on(3),
|
|
off(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Is used for run and stop control of fan1.
|
|
(2) fan will run and stop according to temperature of sensor 1
|
|
and threshold of fan1
|
|
(3) fan will run independent of temperature and threshold
|
|
(4) fan will stop independent of temperature and threshold
|
|
(3) and (4) can be used for alert handling."
|
|
::= { cpqCmcControl 9 }
|
|
|
|
|
|
cpqCmcSetFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
auto(2),
|
|
on(3),
|
|
off(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Is used for run and stop control of fan2.
|
|
(2) fan will run and stop according to temperature of sensor 2
|
|
and threshold of fan2
|
|
(3) fan will run independent of temperature and threshold
|
|
(4) fan will stop independent of temperature and threshold
|
|
(3) and (4) can be used for alert handling"
|
|
::= { cpqCmcControl 10 }
|
|
|
|
|
|
cpqCmcSetQuitRelay1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
switched(2),
|
|
notSwitched(3),
|
|
quit(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status and quit of alarm relay 1.
|
|
(2) relay is switched because of an alarm
|
|
(3) relay is not switched, no alarm
|
|
(4) (set) will quit relay 1 in case of alarm"
|
|
::= { cpqCmcControl 11 }
|
|
|
|
|
|
cpqCmcSetQuitRelay2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
switched(2),
|
|
notSwitched(3),
|
|
quit(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status and quit of alarm relay 2.
|
|
(2) relay is switched because of an alarm
|
|
(3) relay is not switched, no alarm
|
|
(4) (set) will quit relay 2 in case of alarm"
|
|
::= { cpqCmcControl 12 }
|
|
|
|
|
|
cpqCmcLogsNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of Log-entries"
|
|
::= { cpqCmcLog 1 }
|
|
|
|
|
|
cpqCmcLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqCmcLogEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Log-table"
|
|
::= { cpqCmcLog 2 }
|
|
|
|
|
|
cpqCmcLogEntry OBJECT-TYPE
|
|
SYNTAX CpqCmcLogEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Log-table entries"
|
|
INDEX { cpqCmcLogIndex }
|
|
|
|
::= { cpqCmcLogTable 1 }
|
|
|
|
cpqCmcLogEntry ::=
|
|
SEQUENCE {
|
|
cpqCmcLogIndex INTEGER,
|
|
cpqCmcLogDate DisplayString,
|
|
cpqCmcLogTime DisplayString,
|
|
cpqCmcLogText DisplayString,
|
|
cpqCmcLogClass DisplayString
|
|
}
|
|
|
|
cpqCmcLogIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index for the Log-table. Its value ranges between
|
|
1 and the value of cpqCmcLogsNumber "
|
|
::= { cpqCmcLogEntry 1 }
|
|
|
|
|
|
cpqCmcLogDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..11))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Date of log information. "
|
|
::= { cpqCmcLogEntry 2 }
|
|
|
|
|
|
cpqCmcLogTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..11))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Time of log information. "
|
|
::= { cpqCmcLogEntry 3 }
|
|
|
|
|
|
cpqCmcLogText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Log information. "
|
|
::= { cpqCmcLogEntry 4 }
|
|
|
|
|
|
cpqCmcLogClass OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status of log information. "
|
|
::= { cpqCmcLogEntry 5 }
|
|
|
|
|
|
cpqCmcalarm2 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusAlarm2 }
|
|
--#SUMMARY "Location: %s, Message: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "NMSalarm (153018)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "Alarm 2, set from Network management"
|
|
::= 153018
|
|
|
|
|
|
cpqCmcalarmTemp1 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusTemp1 }
|
|
--#SUMMARY "Location: %s, Message: Rack temp sensor 1 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Temperaturealarm (153001)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The temperature at rack sensor 1 is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information."
|
|
::= 153001
|
|
|
|
|
|
cpqCmcalarm1 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusAlarm1 }
|
|
--#SUMMARY "Location: %s, Message: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "NMSalarm (153017)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "Alarm 1, set from Network management"
|
|
::= 153017
|
|
|
|
|
|
cpqCmcalarmLock1Dev TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusLock1Dev }
|
|
--#SUMMARY "Location: %s, Status: door lock device #1 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Doorlockingalarm of device (153019)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The rack door locking device #1 has failed. Action: Check the device lock cable or failed battery and refer to Trap Details for more information."
|
|
::= 153019
|
|
|
|
|
|
cpqCmcalarmFan2 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusFan2 }
|
|
--#SUMMARY "Location: %s, Rack fan 2 status: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Fanalarm (153004)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The status of Fan 2 has changed. Action: Refer to Trap Details for more information."
|
|
::= 153004
|
|
|
|
|
|
cpqCmcalarmFan1 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusFan1 }
|
|
--#SUMMARY "Location: %s, Rack fan 1 status: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Fanalarm (153003)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The status of Fan 1 has changed. Action: Refer to Trap Details for more information."
|
|
::= 153003
|
|
|
|
|
|
cpqCmcalarmVoltage TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusVoltage }
|
|
--#SUMMARY "Location: %s, Message: Rack supply voltage %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Voltagealarm (153005)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The AC voltage of the rack is outside the specified threshold. Action: Check the incoming power source and ensure all cables are inserted correctly."
|
|
::= 153005
|
|
|
|
|
|
cpqCmcalarmLock2Dev TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusLock2Dev }
|
|
--#SUMMARY "Location: %s, Status: door lock device #2 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Doorlockingalarm of device (153020)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The rack door locking device #2 has failed. Action: Check the device lock cable or failed battery and refer to Trap Details for more information."
|
|
::= 153020
|
|
|
|
|
|
cpqCmcalarmShock TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusShock }
|
|
--#SUMMARY "Location: %s, Message: Rack shock detector shock: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Shockalarm (153014)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The rack shock detector has detected a vibration to the rack. Action: Investigate rack."
|
|
::= 153014
|
|
|
|
|
|
cpqCmcalarmLock2 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusLock2Lock }
|
|
--#SUMMARY "Location: %s, Message: Rack lock #1 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Doorlockingalarm (153012)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "Rack door lock #2 alarm. Action: Ensure the door is completely closed and check for unauthorized intrusion and refer to Trap Details for more information."
|
|
::= 153012
|
|
|
|
|
|
cpqCmcalarmLock1 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusLock1Lock }
|
|
--#SUMMARY "Location: %s, Message: Rack lock #1 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Doorlockingalarm (153011)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "Rack door lock #1 alarm. Action: Ensure the door is completely closed and check for unauthorized intrusion and refer to Trap Details for more information."
|
|
::= 153011
|
|
|
|
|
|
cpqCmcalarmHumidity TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusHumidity }
|
|
--#SUMMARY "Location: %s, Message: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Humidityalarm (153006)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The humidity of the rack is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information."
|
|
::= 153006
|
|
|
|
|
|
cpqCmcSetupChanged TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation }
|
|
--#SUMMARY "Location: %s, Name: %s, contact %s"
|
|
--#ARGUMENTS {3,2,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: #"
|
|
--#TYPE "Setup has changed (153100)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "Setup of CMC has changed."
|
|
::= 153100
|
|
|
|
|
|
cpqCmcalarmInput4 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusInput4 }
|
|
--#SUMMARY "Location: %s, Message: Rack access point 4 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Door/sidepanelalarm (153010)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The door or sidepanel of the rack has been opened (access point #4). Action: Check for unauthorized intrusion and refer to Trap Details for more information."
|
|
::= 153010
|
|
|
|
|
|
cpqCmcalarmInput3 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusInput3 }
|
|
--#SUMMARY "Location: %s, Message: Rack access point 3 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Door/sidepanelalarm (153009)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The door or sidepanel of the rack has been opened (access point #3). Action: Check for unauthorized intrusion and refer to Trap Details for more information."
|
|
::= 153009
|
|
|
|
|
|
cpqCmcalarmInput2 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusInput2 }
|
|
--#SUMMARY "Location: %s, Message: Rack access point 2 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Door/sidepanelalarm (153008)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The door or sidepanel of the rack has been opened (access point #2). Action: Check for unauthorized intrusion and refer to Trap Details for more information."
|
|
::= 153008
|
|
|
|
|
|
cpqCmcalarmInput1 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusInput1 }
|
|
--#SUMMARY "Location: %s, Message: Rack access point 1 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Door/sidepanelalarm (153007)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The door or sidepanel of the rack has been opened (access point #1). Action: Check for unauthorized intrusion and refer to Trap Details for more information."
|
|
::= 153007
|
|
|
|
|
|
cpqCmcalarmSmoke TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusSmoke }
|
|
--#SUMMARY "Location: %s, Message: Rack smoke detector smoke: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Smokealarm (153013)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The rack smoke detector has detected smoke. Action: Investigate rack for an over temperature condition and refer to Trap Details for more information."
|
|
::= 153013
|
|
|
|
|
|
cpqCmcalarmAux2 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusAux2 }
|
|
--#SUMMARY "Location: %s, Message: aux input #2 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Auxalarm (153016)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The rack auxiliary alarm input #2 has been triggered."
|
|
::= 153016
|
|
|
|
|
|
cpqCmcalarmAux1 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusAux1 }
|
|
--#SUMMARY "Location: %s, Message: aux input #1 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Auxalarm (153015)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The rack auxiliary alarm input #1 has been triggered."
|
|
::= 153015
|
|
|
|
|
|
cpqCmcalarmTemp2 TRAP-TYPE
|
|
ENTERPRISE cpqCmc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusTemp2 }
|
|
--#SUMMARY "Location: %s, Message: Rack temp sensor 2 %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #"
|
|
--#TYPE "Temperaturealarm (153002)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Remote Management Events"
|
|
DESCRIPTION "The temperature at rack sensor 2 is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information."
|
|
::= 153002
|
|
|
|
|
|
END
|