mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-18 00:13:02 +00:00
255 lines
5.8 KiB
INI
Executable File
255 lines
5.8 KiB
INI
Executable File
#-MIBFILE: cpq54nn.mib
|
|
|
|
CPQN54NN-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
DisplayString ::=
|
|
OCTET STRING
|
|
|
|
PhysAddress ::=
|
|
OCTET STRING
|
|
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
system OBJECT IDENTIFIER ::= { mib-2 1 }
|
|
sysUpTime OBJECT IDENTIFIER ::= { system 3 }
|
|
system OBJECT IDENTIFIER ::= { mib-2 1 }
|
|
sysDescr OBJECT IDENTIFIER ::= { system 1 }
|
|
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
|
|
cpqGigaSwitch OBJECT IDENTIFIER ::= { compaq 111 }
|
|
|
|
cpqGigaSwitchProd OBJECT IDENTIFIER ::= { cpqGigaSwitch 1 }
|
|
|
|
cpqGigaSwitchId5422 OBJECT IDENTIFIER ::= { cpqGigaSwitchProd 1 }
|
|
|
|
cpqGigaSwitchId5411 OBJECT IDENTIFIER ::= { cpqGigaSwitchProd 2 }
|
|
|
|
cpqGigaSwitchMib OBJECT IDENTIFIER ::= { cpqGigaSwitch 3 }
|
|
|
|
cpqGigaSwitchSystem OBJECT IDENTIFIER ::= { cpqGigaSwitchMib 1 }
|
|
|
|
cpqSaveConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
saveToPrimary(1),
|
|
saveToSecondary(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "When this object is set, the device will copy the contents
|
|
of the configuration database to a buffer and save it to the
|
|
persistant store specified by the value of the object. The
|
|
save is performed asynchronously, and the snmp agent will continue
|
|
to respond to both gets and sets while the save is taking
|
|
place. A network management application may use the
|
|
cpqSaveStatus object to determine when the asynchronous
|
|
save operation has completed."
|
|
::= { cpqGigaSwitchSystem 3 }
|
|
|
|
|
|
cpqSaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
saveInProgress(1),
|
|
saveNotInProgress(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This object will return the status of a save operation invoked
|
|
by setting the cpqSaveConfiguration object. A network
|
|
management application can read this object to determine that a
|
|
save operation has completed."
|
|
::= { cpqGigaSwitchSystem 4 }
|
|
|
|
|
|
cpqCurrentConfigInUse OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary(1),
|
|
secondary(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Shows which configuration store was used at last boot"
|
|
::= { cpqGigaSwitchSystem 5 }
|
|
|
|
|
|
cpqConfigToUseOnReboot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary(1),
|
|
secondary(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Controls which configuration store will be used on next reboot."
|
|
::= { cpqGigaSwitchSystem 6 }
|
|
|
|
|
|
cpqOids OBJECT IDENTIFIER ::= { cpqGigaSwitch 2 }
|
|
|
|
cpqMauType OBJECT IDENTIFIER ::= { cpqOids 1 }
|
|
|
|
cpqMauType1000BaseSX OBJECT IDENTIFIER ::= { cpqMauType 1 }
|
|
|
|
cpqMauType1000BaseLX OBJECT IDENTIFIER ::= { cpqMauType 2 }
|
|
|
|
cpqMauType1000BaseCX OBJECT IDENTIFIER ::= { cpqMauType 3 }
|
|
|
|
cpqMauType1000BaseSXFD OBJECT IDENTIFIER ::= { cpqMauType 4 }
|
|
|
|
cpqMauType1000BaseLXFD OBJECT IDENTIFIER ::= { cpqMauType 5 }
|
|
|
|
cpqMauType1000BaseCXFD OBJECT IDENTIFIER ::= { cpqMauType 6 }
|
|
|
|
|
|
overheat TRAP-TYPE
|
|
ENTERPRISE cpqGigaSwitch
|
|
VARIABLES { sysUpTime, sysDescr }
|
|
|
|
--#TYPE "overheat"
|
|
|
|
--#SUMMARY "overheat"
|
|
|
|
--#ARGUMENTS {2}
|
|
|
|
--#SEVERITY CRITICAL
|
|
--#CATEGORY "Giga Switch Events"
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "A overheat trap indicates that the on board
|
|
tempature sensor has reported a overheat
|
|
condition. System will shutdown until unit has
|
|
sufficiently cooled such that operation may begin
|
|
again. A cold start trap will be issued when
|
|
the unit has come back on line."
|
|
::= 6
|
|
|
|
|
|
fanfailed TRAP-TYPE
|
|
ENTERPRISE cpqGigaSwitch
|
|
VARIABLES { sysUpTime, sysDescr }
|
|
|
|
--#TYPE "fanfailed"
|
|
|
|
--#SUMMARY "fanfailed"
|
|
|
|
--#ARGUMENTS {2}
|
|
|
|
--#SEVERITY MAJOR
|
|
--#CATEGORY "Giga Switch Events"
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "A fan failed trap indicates one or more of the
|
|
cooling fans inside the device has failed. A
|
|
fanOK trap will be sent once the fan has attained
|
|
normal operation."
|
|
::= 7
|
|
|
|
|
|
fanOK TRAP-TYPE
|
|
ENTERPRISE cpqGigaSwitch
|
|
VARIABLES { sysUpTime, sysDescr }
|
|
|
|
--#TYPE "fanOk"
|
|
|
|
--#SUMMARY "fanOk"
|
|
|
|
--#ARGUMENTS {2}
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY "Giga Switch Events"
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "A fan has transitioned out of a failure state and
|
|
is now operating correctly."
|
|
::= 8
|
|
|
|
|
|
invalidLoginAttempt TRAP-TYPE
|
|
ENTERPRISE cpqGigaSwitch
|
|
VARIABLES { sysUpTime, sysDescr }
|
|
|
|
--#TYPE "invalidLoginAttempt"
|
|
|
|
--#SUMMARY "invalidLoginAttempt"
|
|
|
|
--#ARGUMENTS {2}
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY "Giga Switch Events"
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "A user attempted to login to console or by telnet but was refused
|
|
access due to incorrect username or password"
|
|
::= 9
|
|
|
|
|
|
powerSupplyFail TRAP-TYPE
|
|
ENTERPRISE cpqGigaSwitch
|
|
VARIABLES { sysUpTime, sysDescr }
|
|
|
|
--#TYPE "powerSupplyFail"
|
|
|
|
--#SUMMARY "powerSupplyFail"
|
|
|
|
--#ARGUMENTS {2}
|
|
|
|
--#SEVERITY MAJOR
|
|
--#CATEGORY "Giga Switch Events"
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "One or more sources of power to this agent has failed.
|
|
Presumably a redundant power-supply has taken over."
|
|
::= 10
|
|
|
|
|
|
powerSupplyGood TRAP-TYPE
|
|
ENTERPRISE cpqGigaSwitch
|
|
VARIABLES { sysUpTime, sysDescr }
|
|
|
|
--#TYPE "powerSupplyGood"
|
|
|
|
--#SUMMARY "powerSupplyGood"
|
|
|
|
--#ARGUMENTS {2}
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY "Giga Switch Events"
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "One or more previously bad sources of power to this agent
|
|
has come back to life without causing an agent restart."
|
|
::= 11
|
|
|
|
|
|
rpsAlarm TRAP-TYPE
|
|
ENTERPRISE cpqGigaSwitch
|
|
VARIABLES { sysUpTime, sysDescr }
|
|
|
|
--#TYPE "rpsAlrm"
|
|
|
|
--#SUMMARY "rpsAlarm"
|
|
|
|
--#ARGUMENTS {2}
|
|
|
|
--#SEVERITY MAJOR
|
|
--#CATEGORY "Giga Switch Events"
|
|
--#TIMEINDEX 99
|
|
DESCRIPTION "Attached Redundant Power Supply device is indicating
|
|
an alarm condition."
|
|
::= 12
|
|
|
|
|
|
rpsNoAlarm TRAP-TYPE
|
|
ENTERPRISE cpqGigaSwitch
|
|
VARIABLES { sysUpTime, sysDescr }
|
|
|
|
--#TYPE "rpsNoAlarm"
|
|
|
|
--#SUMMARY "rpsNoAlarm"
|
|
|
|
--#ARGUMENTS {2}
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
|
|
--#TIMEINDEX 99
|
|
--#CATEGORY "Giga Switch Events"
|
|
DESCRIPTION "Attached Redundant Power Supply device is no longer
|
|
indicating an alarm condition."
|
|
::= 13
|
|
|
|
|
|
END
|
|
|