RC-POM-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TruthValue
|
|
FROM SNMPv2-TC
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
rcPlugOptMod, EnableValue
|
|
FROM RAPID-CITY;
|
|
|
|
rcPlugOptModTableMib MODULE-IDENTITY
|
|
LAST-UPDATED "200805090000Z"
|
|
ORGANIZATION "Nortel Networks"
|
|
CONTACT-INFO "Dwight Croonenberghs
|
|
Postal: Nortel Networks, Inc.
|
|
600 Technology Park
|
|
Billerica, MA 01821
|
|
E-mail: dwightc@nortel.com"
|
|
DESCRIPTION "OE MIB for Digital Diagnostic Monitoring of pluggable optical modules"
|
|
|
|
REVISION "200805090000Z" -- 09 May 2008
|
|
DESCRIPTION "Version 4: Fixed smilint errors."
|
|
|
|
REVISION "200801160000Z" -- 16 Jan. 2008
|
|
DESCRIPTION "Version 3: Removed rcPlugOptModConfigTable and changed the global config scalar names"
|
|
|
|
REVISION "200712170000Z" -- 17 Dec. 2007
|
|
DESCRIPTION "Version 2: added rcPlugOptModConfigTable and
|
|
rcPlugOptModAlarmMonitorGlobalEnable
|
|
rcPlugOptModWarningMonitorGlobalEnable
|
|
rcPlugOptModAlarmMonitorInterval
|
|
rcPlugOptModWarningMonitorInterval"
|
|
|
|
REVISION "200610200000Z" -- 20 Oct. 2006
|
|
DESCRIPTION "Version 1: Initial version; added rcPlugOptModTable"
|
|
::= { rcPlugOptMod 0 }
|
|
|
|
|
|
-- This MIB defines the serial information that can be read from
|
|
-- SFPs and SFPs including the vendor specific Nortel supplied data.
|
|
-- The INF-8074i SFP MSA and the SFF-8053 SFP specifications defined
|
|
-- the first 256 bytes of serial ID information. The SFF-8472
|
|
-- standard adds new options to those previously defined and adds
|
|
-- new transceiver types. The SFF-8472 standard also defines an
|
|
-- enhanced digital diagnostic monitoring interface for optical
|
|
-- devices which allows real-time access to device operating
|
|
-- parameters.
|
|
--
|
|
-- If the target device supports the SFF-8472 standard, there is an
|
|
-- extra 256 bit address space. Pertinant information from that
|
|
-- space is also described here.
|
|
-- TXT about XFPs
|
|
|
|
|
|
rcPlugOptModTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcPlugOptModEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Gibc SFF diagnostic info table"
|
|
::= { rcPlugOptMod 1 }
|
|
|
|
rcPlugOptModEntry OBJECT-TYPE
|
|
SYNTAX RcPlugOptModEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry containing info. for a particular port"
|
|
INDEX { rcPlugOptModPortIndex }
|
|
::= { rcPlugOptModTable 1 }
|
|
|
|
RcPlugOptModEntry ::= SEQUENCE {
|
|
rcPlugOptModPortIndex InterfaceIndex, -- 1
|
|
|
|
-- Control information:
|
|
|
|
rcPlugOptModDdmStatusMask BITS, -- 2
|
|
rcPlugOptModCalibration INTEGER, -- 3
|
|
rcPlugOptModPowerMeasure INTEGER, -- 4
|
|
rcPlugOptModConnectorType DisplayString, -- 5 ; 16+1
|
|
rcPlugOptModVendorName DisplayString, -- 6 ; 16+1
|
|
rcPlugOptModVendorPartNumber DisplayString, -- 7 ; 16+1
|
|
rcPlugOptModVendorRevNumber DisplayString, -- 8 ; 4+1
|
|
rcPlugOptModVendorSN DisplayString, -- 9 ; 16+1
|
|
rcPlugOptModVendorDateCode DisplayString, -- 10; 8+1
|
|
|
|
-- Vendor information:
|
|
|
|
rcPlugOptModPEC DisplayString, -- 11 ;16+1
|
|
rcPlugOptModCLEI DisplayString, -- 12 ;10+1
|
|
rcPlugOptModSupportsDDM TruthValue, -- 13
|
|
rcPlugOptModAux1Monitoring INTEGER, -- 14
|
|
rcPlugOptModAux2Monitoring INTEGER, -- 15
|
|
rcPlugOptModWaveLength Integer32, -- 16
|
|
|
|
-- The DDM information:
|
|
|
|
rcPlugOptModTemperature Integer32, -- 17
|
|
rcPlugOptModTemperatureHighAlarmThreshold Integer32, -- 18
|
|
rcPlugOptModTemperatureLowAlarmThreshold Integer32, -- 19
|
|
rcPlugOptModTemperatureHighWarningThreshold Integer32, -- 20
|
|
rcPlugOptModTemperatureLowWarningThreshold Integer32, -- 21
|
|
rcPlugOptModVoltage Integer32, -- 22
|
|
rcPlugOptModVoltageHighAlarmThreshold Integer32, -- 23
|
|
rcPlugOptModVoltageLowAlarmThreshold Integer32, -- 24
|
|
rcPlugOptModVoltageHighWarningThreshold Integer32, -- 25
|
|
rcPlugOptModVoltageLowWarningThreshold Integer32, -- 26
|
|
rcPlugOptModBias Integer32, -- 27
|
|
rcPlugOptModBiasHighAlarmThreshold Integer32, -- 28
|
|
rcPlugOptModBiasLowAlarmThreshold Integer32, -- 29
|
|
rcPlugOptModBiasHighWarningThreshold Integer32, -- 30
|
|
rcPlugOptModBiasLowWarningThreshold Integer32, -- 31
|
|
rcPlugOptModTxPower Integer32, -- 32
|
|
rcPlugOptModTxPowerHighAlarmThreshold Integer32, -- 33
|
|
rcPlugOptModTxPowerLowAlarmThreshold Integer32, -- 34
|
|
rcPlugOptModTxPowerHighWarningThreshold Integer32, -- 35
|
|
rcPlugOptModTxPowerLowWarningThreshold Integer32, -- 36
|
|
rcPlugOptModRxPower Integer32, -- 37
|
|
rcPlugOptModRxPowerHighAlarmThreshold Integer32, -- 38
|
|
rcPlugOptModRxPowerLowAlarmThreshold Integer32, -- 39
|
|
rcPlugOptModRxPowerHighWarningThreshold Integer32, -- 40
|
|
rcPlugOptModRxPowerLowWarningThreshold Integer32, -- 41
|
|
rcPlugOptModAux1 Integer32, -- 42
|
|
rcPlugOptModAux1HighAlarmThreshold Integer32, -- 43
|
|
rcPlugOptModAux1LowAlarmThreshold Integer32, -- 44
|
|
rcPlugOptModAux1HighWarningThreshold Integer32, -- 45
|
|
rcPlugOptModAux1LowWarningThreshold Integer32, -- 46
|
|
rcPlugOptModAux2 Integer32, -- 47
|
|
rcPlugOptModAux2HighAlarmThreshold Integer32, -- 48
|
|
rcPlugOptModAux2LowAlarmThreshold Integer32, -- 49
|
|
rcPlugOptModAux2HighWarningThreshold Integer32, -- 50
|
|
rcPlugOptModAux2LowWarningThreshold Integer32, -- 51
|
|
|
|
rcPlugOptModTemperatureStatus INTEGER, -- 52
|
|
rcPlugOptModVoltageStatus INTEGER, -- 53
|
|
rcPlugOptModBiasStatus INTEGER, -- 54
|
|
rcPlugOptModTxPowerStatus INTEGER, -- 55
|
|
rcPlugOptModRxPowerStatus INTEGER, -- 56
|
|
rcPlugOptModAux1Status INTEGER, -- 57
|
|
rcPlugOptModAux2Status INTEGER -- 58
|
|
}
|
|
|
|
rcPlugOptModPortIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An index value that uniquely identifies a port on a
|
|
blade or line-card."
|
|
::= { rcPlugOptModEntry 1 }
|
|
|
|
rcPlugOptModDdmStatusMask OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
ddm-ok(0),
|
|
ddm-checksum-error(1),
|
|
ddm-i2c-read-error(2),
|
|
ddm-threshold-error(3),
|
|
ddm-calibration-error(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Each bit other than ddm-ok represents a specific error.
|
|
Any combination of error bits is allowed."
|
|
::= { rcPlugOptModEntry 2}
|
|
|
|
rcPlugOptModCalibration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internal (1),
|
|
external (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The identifier value indicates type of calibration."
|
|
::= { rcPlugOptModEntry 3}
|
|
|
|
rcPlugOptModPowerMeasure OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
omi (1),
|
|
average (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The identifier value indicates type of external power."
|
|
::= { rcPlugOptModEntry 4}
|
|
|
|
rcPlugOptModConnectorType OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(17)) -- 16+1
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The connector type is a 16 character field that
|
|
contains ASCII characters, left-aligned and padded
|
|
on the right with ASCII spaces. This is an assigned
|
|
name that indicates some characteristic of the
|
|
layer-1 interface."
|
|
::= { rcPlugOptModEntry 5 }
|
|
|
|
rcPlugOptModVendorName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(17)) -- 16+1
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The vendor name is a 16 character field that
|
|
contains ASCII characters, left-aligned and padded
|
|
on the right with ASCII spaces. The vendor name
|
|
shall be the full name of the corporation, a
|
|
commonly accepted abbreviation of the name, the
|
|
SCSI company code, or the stock exchange code for
|
|
the corporation."
|
|
::= { rcPlugOptModEntry 6 }
|
|
|
|
rcPlugOptModVendorPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(17)) -- 16+1
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The vendor part number is a 16 byte field that
|
|
contains ASCII characters, left-aligned and padded
|
|
on the right with ASCII spaces, defining the vendor
|
|
part number or product name."
|
|
::= { rcPlugOptModEntry 7 }
|
|
|
|
rcPlugOptModVendorRevNumber OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(5)) -- 4+1
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The vendor revision number is a 4-byte field that
|
|
contains ASCII characters, left-aligned and padded
|
|
on the right with ASCII spaces, defining the
|
|
vendor product revision number."
|
|
::= { rcPlugOptModEntry 8 }
|
|
|
|
rcPlugOptModVendorSN OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(17)) -- 16+1
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The vendor serial number is a 16 character field
|
|
that contains ASCII characters, left-aligned and
|
|
padded on the right with ASCII spaces, defining
|
|
the vendor serial number for the transceiver."
|
|
::= { rcPlugOptModEntry 9 }
|
|
|
|
rcPlugOptModVendorDateCode OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(9)) -- 8+1
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date code is an 8-byte field that contains the
|
|
vendor's date code in ASCII. This field is
|
|
mandatory and takes the form: YYMMDDLC where
|
|
YY is the 2 low order digits of the year (00=2000),
|
|
MM is the month, 01 thru 12,
|
|
DD is the day, 01 thru 31, and
|
|
LC is an optional vendor specific lot code."
|
|
::= { rcPlugOptModEntry 10 }
|
|
|
|
rcPlugOptModPEC OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(17)) -- 16+1
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is a 16 byte left-justified ASCII field that
|
|
records the Nortel Product Equipment Code order
|
|
number for the module. Nortel part numbers are 9
|
|
bytes long, so the 10th through 16th byte should
|
|
be NULL."
|
|
::= { rcPlugOptModEntry 11 }
|
|
|
|
rcPlugOptModCLEI OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(11)) -- 10+1
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is a 10 byte left-justified ASCII field that
|
|
records the Nortel supplied Common Language
|
|
Equipment Identifier code for the device. The CLEI
|
|
code is a Telcordia human-readable representation
|
|
of the 1D barcode."
|
|
::= { rcPlugOptModEntry 12 }
|
|
|
|
rcPlugOptModSupportsDDM OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This boolean indicates whether or not the device
|
|
supports the DDM capability."
|
|
::= { rcPlugOptModEntry 13 }
|
|
|
|
rcPlugOptModAux1Monitoring OBJECT-TYPE
|
|
SYNTAX INTEGER(0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value tells what Aux1 is measuring.The values are
|
|
as follows:
|
|
|
|
0 Auxiliary monitoring not implemented
|
|
1 APD Bias Voltage mV (units of 10 mV)
|
|
2 Reserved
|
|
3 TEC Current (mA)
|
|
4 Laser Temperature
|
|
5 Laser Wavelength
|
|
6 +5V Supply Voltage
|
|
7 +3.3V Supply Voltage
|
|
8 +1.8V Supply Voltage
|
|
9 -5.2V Supply Voltage
|
|
10 +5.0V Supply Current (unit of 100 uA)
|
|
13 +3.3V Supply Current (unit of 100 uA)
|
|
14 +1.8V Supply Current (unit of 100 uA)
|
|
15 -5.2V Supply Current (unit of 100 uA)
|
|
"
|
|
::= { rcPlugOptModEntry 14 }
|
|
|
|
rcPlugOptModAux2Monitoring OBJECT-TYPE
|
|
SYNTAX INTEGER(0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value tells you what AUX2 is measuring.The values are
|
|
as follows:
|
|
|
|
0 Auxiliary monitoring not implemented
|
|
1 APD Bias Voltage mV (units of 10 mV)
|
|
2 Reserved
|
|
3 TEC Current (mA)
|
|
4 Laser Temperature
|
|
5 Laser Wavelength
|
|
6 +5V Supply Voltage
|
|
7 +3.3V Supply Voltage
|
|
8 +1.8V Supply Voltage
|
|
9 -5.2V Supply Voltage
|
|
10 +5.0V Supply Current (unit of 100 uA)
|
|
13 +3.3V Supply Current (unit of 100 uA)
|
|
14 +1.8V Supply Current (unit of 100 uA)
|
|
15 -5.2V Supply Current (unit of 100 uA)
|
|
"
|
|
::= { rcPlugOptModEntry 15 }
|
|
|
|
rcPlugOptModWaveLength OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Nominal transmitter output wavelength at room
|
|
temperature. It is expressed in nano-meters."
|
|
::= {rcPlugOptModEntry 16 }
|
|
|
|
|
|
-- These next variables represent either measured values or fixed
|
|
-- threshold values. Sometimes they involve an integer and a fractional
|
|
-- component and sometimes we may want to convert from mW to dBm.
|
|
-- So maybe what we have in the MIB definition is not the raw numeric
|
|
-- data but rather the ASCII representation of that data including a
|
|
-- minus sign, if necessary, and a decimal point in the right place.
|
|
-- In all cases, we need to display the calibrated data if external
|
|
-- calibration is being used. For temperature, voltage, bias current
|
|
-- and transmitter power, this involves multiplying the raw value by
|
|
-- a vendor specified slope constant (contained in the device EEPROM)
|
|
-- then adding a vendor specified offset (also contained in the device
|
|
-- EEPROM). For received power, it involves running the raw value
|
|
-- through a polynomial. The vendor specified coefficients for that
|
|
-- polynomial are contained in the device in IEEE 754 floating-point
|
|
-- format.
|
|
|
|
rcPlugOptModTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the internally measured
|
|
module temperature. It is expressed in units of
|
|
1/256 of a degree Celsius and can range from -40C
|
|
to +125C with 0.0001 accuracy.The most significant byte is
|
|
the signed integer part of the number and the
|
|
least significant byte is the fraction."
|
|
::= { rcPlugOptModEntry 17 }
|
|
|
|
rcPlugOptModTemperatureHighAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
temperature threshold. If the device
|
|
temperature exceeds this value, a temperature high
|
|
is asserted. It is expressed in the same
|
|
units as the measured temperature."
|
|
::= { rcPlugOptModEntry 18 }
|
|
|
|
rcPlugOptModTemperatureLowAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
temperature threshold. If the device
|
|
temperature falls below this value, a temperature
|
|
low is asserted. It is expressed in the same
|
|
units as the measured temperature."
|
|
::= { rcPlugOptModEntry 19 }
|
|
|
|
rcPlugOptModTemperatureHighWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
temperature warning threshold. If the device
|
|
temperature exceeds this value, a temperature high
|
|
warning is asserted. It is expressed in the same
|
|
units as the measured temperature."
|
|
::= { rcPlugOptModEntry 20 }
|
|
|
|
rcPlugOptModTemperatureLowWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
temperature warning threshold. If the device
|
|
temperature falls below this value, a temperature
|
|
low warning is asserted. It is expressed in the
|
|
same units as the measured temperature."
|
|
::= { rcPlugOptModEntry 21 }
|
|
|
|
rcPlugOptModVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the internally measured
|
|
supply voltage. It is a positive number expressed
|
|
in microvolts and can range from 0 to 65535 mV."
|
|
::= { rcPlugOptModEntry 22 }
|
|
|
|
rcPlugOptModVoltageHighAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
voltage threshold. If the measured voltage exceeds
|
|
this value, a high voltage is asserted. It
|
|
is a positive number expressed in microvolts."
|
|
::= { rcPlugOptModEntry 23 }
|
|
|
|
rcPlugOptModVoltageLowAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
voltage threshold. If the measured voltage falls
|
|
below this value, a low voltage is asserted.
|
|
It is a positive number expressed in microvolts."
|
|
::= { rcPlugOptModEntry 24 }
|
|
|
|
rcPlugOptModVoltageHighWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
voltage warning threshold. If the measured voltage
|
|
exceeds this value, a high voltage warning is
|
|
asserted. It is a positive number expressed in
|
|
microvolts."
|
|
::= { rcPlugOptModEntry 25 }
|
|
|
|
rcPlugOptModVoltageLowWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
voltage warning threshold. If the measured voltage
|
|
falls below this value, a low voltage warning is
|
|
asserted. It is a positive number expressed in
|
|
microvolts."
|
|
::= { rcPlugOptModEntry 26 }
|
|
|
|
rcPlugOptModBias OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the internally measured
|
|
transmitter laser bias current. It is a positive
|
|
number expressed in units of 2 microamps and can
|
|
range from 0 to 131 mA with 0.0001 accuracy."
|
|
::= { rcPlugOptModEntry 27 }
|
|
|
|
rcPlugOptModBiasHighAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
current threshold. If the measured bias
|
|
current exceeds this value, a high current alarm
|
|
is asserted. It is a positive number expressed
|
|
in units of 2 microamps and can range from 0 to
|
|
131 mA with 0.0001 accuracy."
|
|
::= { rcPlugOptModEntry 28 }
|
|
|
|
rcPlugOptModBiasLowAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
current threshold. If the measured bias
|
|
current falls below this value, a low current
|
|
is asserted. It is a positive number
|
|
expressed in units of 2 microamps and can range
|
|
from 0 to 131 mA with 0.0001 accuracy."
|
|
::= { rcPlugOptModEntry 29 }
|
|
|
|
rcPlugOptModBiasHighWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
current warning threshold. If the measured bias
|
|
current exceeds this value, a high current warning
|
|
is asserted. It is a positive number expressed in
|
|
units of 2 microamps and can range from 0 to
|
|
131 mA with 0.0001 accuracy."
|
|
::= { rcPlugOptModEntry 30 }
|
|
|
|
rcPlugOptModBiasLowWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
current warning threshold. If the measured bias
|
|
current falls below this value, a low current
|
|
warning is asserted. It is a positive number
|
|
expressed in units of 2 microamps and can range
|
|
from 0 to 131 mA with 0.0001 accuracy."
|
|
::= { rcPlugOptModEntry 31 }
|
|
|
|
-- For power readings, we should really display these values in dBm
|
|
-- CP code can convert from mW to dBm.
|
|
|
|
rcPlugOptModTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the internally measured
|
|
coupled TX output power. It is a positive number
|
|
expressed in units of micro watts and can range
|
|
from 0 to 65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 32 }
|
|
|
|
rcPlugOptModTxPowerHighAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
transmit power threshold. If the measured
|
|
transmitter power exceeds this value, a
|
|
transmitter power high is asserted. It is
|
|
a positive number expressed in units of micro
|
|
watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 33 }
|
|
|
|
rcPlugOptModTxPowerLowAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
transmit power threshold. If the measured
|
|
transmitter power falls below this value, a
|
|
transmitter power low is asserted. It is a
|
|
positive number expressed in units of micro watts
|
|
and can range from 0 to 65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 34 }
|
|
|
|
rcPlugOptModTxPowerHighWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
transmit power warning threshold. If the measured
|
|
transmitter power exceeds this value, a
|
|
transmitter power high warning is asserted. It is
|
|
a positive number expressed in units of units of
|
|
micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 35 }
|
|
|
|
rcPlugOptModTxPowerLowWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
transmit power warning threshold. If the measured
|
|
transmitter power falls below this value, a
|
|
transmitter power low warning is asserted. It is
|
|
a positive number expressed in units of micro
|
|
watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 36 }
|
|
|
|
rcPlugOptModRxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the internally measured
|
|
received power. It is a positive number expressed
|
|
in units of micro watts and can range from 0 to
|
|
65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 37 }
|
|
|
|
rcPlugOptModRxPowerHighAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
receiver power threshold. If the measured
|
|
received power exceeds this value, a receiver
|
|
power high is asserted. It is a positive
|
|
number expressed in units of micro watts and can
|
|
range from 0 to 65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 38 }
|
|
|
|
rcPlugOptModRxPowerLowAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
receiver power threshold. If the measured
|
|
received power falls below this value, a receiver
|
|
power low is asserted. It is a positive
|
|
number expressed in units of micro watts and can
|
|
range from 0 to 65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 39 }
|
|
|
|
rcPlugOptModRxPowerHighWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
receiver power warning threshold. If the measured
|
|
received power exceeds this value, a receiver
|
|
power high warning is asserted. It is a positive
|
|
number expressed in units of units of micro watts
|
|
and can range from 0 to 65.535 uW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 40 }
|
|
|
|
rcPlugOptModRxPowerLowWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
receiver power warning threshold. If the measured
|
|
received power falls below this value, a receiver
|
|
power low warning is asserted. It is a positive
|
|
number expressed in units of units of micro watts
|
|
and can range from 0 to 65.535 mW (-40 to 18.16 dBm)."
|
|
::= { rcPlugOptModEntry 41 }
|
|
|
|
rcPlugOptModAux1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This represents the internally measured A/D
|
|
value specified."
|
|
::= { rcPlugOptModEntry 42 }
|
|
|
|
rcPlugOptModAux1HighAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
Aux1 threshold."
|
|
::= { rcPlugOptModEntry 43 }
|
|
|
|
rcPlugOptModAux1LowAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
Aux1 threshold."
|
|
::= { rcPlugOptModEntry 44 }
|
|
|
|
rcPlugOptModAux1HighWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
Aux1 warning threshold."
|
|
::= { rcPlugOptModEntry 45 }
|
|
|
|
rcPlugOptModAux1LowWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
Aux1 warning threshold."
|
|
::= { rcPlugOptModEntry 46 }
|
|
|
|
rcPlugOptModAux2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This represents the internally measured A/D
|
|
value specified."
|
|
::= { rcPlugOptModEntry 47 }
|
|
|
|
rcPlugOptModAux2HighAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
Aux1 threshold."
|
|
::= { rcPlugOptModEntry 48 }
|
|
|
|
rcPlugOptModAux2LowAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
Aux1 threshold."
|
|
::= { rcPlugOptModEntry 49 }
|
|
|
|
rcPlugOptModAux2HighWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified high
|
|
Aux1 warning threshold."
|
|
::= { rcPlugOptModEntry 50 }
|
|
|
|
rcPlugOptModAux2LowWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This value represents the vendor specified low
|
|
Aux1 warning threshold."
|
|
::= { rcPlugOptModEntry 51 }
|
|
|
|
|
|
|
|
-- These next entries represent the defined and warning bits
|
|
-- contained in DDI bytes at offsets 112 thru 117.
|
|
|
|
rcPlugOptModTemperatureStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
highWarning(2),
|
|
highAlarm(3),
|
|
lowWarning(4),
|
|
lowAlarm(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Used to indicate the current temperature status"
|
|
DEFVAL { normal }
|
|
::= { rcPlugOptModEntry 52 }
|
|
|
|
rcPlugOptModVoltageStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
highWarning(2),
|
|
highAlarm(3),
|
|
lowWarning(4),
|
|
lowAlarm(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Used to indicate the current voltage status"
|
|
DEFVAL { normal }
|
|
::= { rcPlugOptModEntry 53 }
|
|
|
|
|
|
rcPlugOptModBiasStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
highWarning(2),
|
|
highAlarm(3),
|
|
lowWarning(4),
|
|
lowAlarm(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Used to indicate the current laser bias status"
|
|
DEFVAL { normal }
|
|
::= { rcPlugOptModEntry 54 }
|
|
|
|
rcPlugOptModTxPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
highWarning(2),
|
|
highAlarm(3),
|
|
lowWarning(4),
|
|
lowAlarm(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Used to indicate the current transmitter power
|
|
status"
|
|
DEFVAL { normal }
|
|
::= { rcPlugOptModEntry 55 }
|
|
|
|
rcPlugOptModRxPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
highWarning(2),
|
|
highAlarm(3),
|
|
lowWarning(4),
|
|
lowAlarm(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Used to indicate the current receiver power status"
|
|
DEFVAL { normal }
|
|
::= { rcPlugOptModEntry 56 }
|
|
|
|
rcPlugOptModAux1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
highWarning(2),
|
|
highAlarm(3),
|
|
lowWarning(4),
|
|
lowAlarm(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Used to indicate the current Aux1 status"
|
|
DEFVAL { normal }
|
|
::= { rcPlugOptModEntry 57 }
|
|
|
|
rcPlugOptModAux2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
highWarning(2),
|
|
highAlarm(3),
|
|
lowWarning(4),
|
|
lowAlarm(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Used to indicate the current Aux2 status"
|
|
DEFVAL { normal }
|
|
::= { rcPlugOptModEntry 58 }
|
|
|
|
-- ----------------------------------------------------------
|
|
--Global configuration of DDI
|
|
-- ----------------------------------------------------------
|
|
|
|
rcPlugOptModScalars OBJECT IDENTIFIER ::= { rcPlugOptMod 2 }
|
|
|
|
rcPlugOptModDdmMonitor OBJECT-TYPE
|
|
SYNTAX EnableValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable/disable the global polling monitor for DDM"
|
|
DEFVAL { disable }
|
|
::= { rcPlugOptModScalars 1 }
|
|
|
|
rcPlugOptModDdmMonitorInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (5..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicate the interval in which the DDM alert registers is polled"
|
|
DEFVAL { 5 }
|
|
::= { rcPlugOptModScalars 2 }
|
|
|
|
rcPlugOptModDdmTrapSend OBJECT-TYPE
|
|
SYNTAX EnableValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Enable/disable the global ddm trap send to SNMP manager "
|
|
DEFVAL { enable }
|
|
::= { rcPlugOptModScalars 3 }
|
|
|
|
rcPlugOptModDdmAlarmPortdown OBJECT-TYPE
|
|
SYNTAX EnableValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Enable/disable the global portdown option when ddm alarm occurs "
|
|
DEFVAL { enable }
|
|
::= { rcPlugOptModScalars 4 }
|
|
|
|
|
|
END
|