-- CISCO-MGX82XX-DSX3-MIB: DS3/E3 interface MIB for MGX82xx products.
|
|
--
|
|
-- January 2003, Jyotsna Gummaraju
|
|
-- December 2002, Subra Hegde
|
|
--
|
|
-- Copyright (c) 2002 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
CISCO-MGX82XX-DSX3-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Counter32,
|
|
Integer32 FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
DisplayString FROM SNMPv2-TC
|
|
dsx3Line,dsx3Framing FROM BASIS-MIB
|
|
ciscoWan FROM CISCOWAN-SMI;
|
|
|
|
ciscoMgx82xxDsx3MIB MODULE-IDENTITY
|
|
LAST-UPDATED "200301110000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-wanatm@cisco.com"
|
|
DESCRIPTION
|
|
"The MIB Module for DS3/E3 interface
|
|
configuration , statistics and Alarm
|
|
configuration.
|
|
|
|
This MIB is supported in T3/E3 service modules
|
|
in MGX products.
|
|
Some of the T3/E3 service modules(Cards) are:
|
|
|
|
PXM1 : Processor Switch Module.
|
|
CESM-T3E3: Circuit Emulation Service Module
|
|
FRSM-VHS : Frame Relay Service Module. Includes
|
|
T3 and Channelized T3 categories.
|
|
FRSM-2CT3: Channelized FRSM Module
|
|
SRM-3T3 : Service Resource Module
|
|
|
|
Terminologies Used :
|
|
|
|
SDH : SONET Digital Hierarchy
|
|
PLCP : Physical Layer Convergence Procedure.
|
|
BERT : Bit Error Rate Testing.
|
|
FEAC : Far End Alarm Code.
|
|
OOF : Out Of Frame.
|
|
AIS : Alarm Indication Signal.
|
|
LOF : Loss Of Frame.
|
|
RAI : Remote Alarm Indication.
|
|
|
|
HCS : Header Check Sequence
|
|
HEC : Header Error Control
|
|
|
|
MA byte : Maintenance and Adaptation byte
|
|
|
|
Tx MA Byte: This is explained in ITU-T G.832
|
|
This Byte contains following fields:
|
|
Payload type
|
|
Payload dependent bits
|
|
Timing maker bit
|
|
|
|
Rx MA Byte: This is explained in ITU-T G.832
|
|
This Byte contains following fields:
|
|
Payload type
|
|
Timing maker bit
|
|
"
|
|
|
|
REVISION "200301110000Z"
|
|
DESCRIPTION
|
|
"Initial version of the MIB.
|
|
|
|
The content of this MIB was originally available
|
|
in CISCO-WAN-AXIPOP-MIB defined using SMIv1.
|
|
The applicable objects from CISCO-WAN-AXIPOP-MIB
|
|
are defined using SMIv2 in this MIB. Also the
|
|
descriptions of some of the objects have been
|
|
modified."
|
|
::= { ciscoWan 59 }
|
|
|
|
|
|
dsx3Config OBJECT IDENTIFIER ::= { dsx3Line 1 }
|
|
dsx3AlarmConfig OBJECT IDENTIFIER ::= { dsx3Line 2 }
|
|
dsx3Alarm OBJECT IDENTIFIER ::= { dsx3Line 3 }
|
|
dsx3Counter OBJECT IDENTIFIER ::= { dsx3Line 4 }
|
|
|
|
|
|
dsx3PlcpConfig OBJECT IDENTIFIER ::= { dsx3Framing 1 }
|
|
dsx3PlcpAlarmConfig OBJECT IDENTIFIER ::= { dsx3Framing 2 }
|
|
dsx3PlcpAlarm OBJECT IDENTIFIER ::= { dsx3Framing 3 }
|
|
dsx3PlcpCounter OBJECT IDENTIFIER ::= { dsx3Framing 4 }
|
|
|
|
-- --------------------------------------------------------------
|
|
--
|
|
-- dsx3Config group
|
|
-- This group contains dsx3 line configuration table
|
|
--
|
|
-- --------------------------------------------------------------
|
|
cwDsx3ConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwDsx3ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DS3/E3 Configuration table. There is one row for each
|
|
DSX3 port in the system. The table size (number of
|
|
rows) is given by the value of dsx3LineNumOfValidEntries."
|
|
::= { dsx3Config 1 }
|
|
|
|
cwDsx3ConfigEntry OBJECT-TYPE
|
|
SYNTAX CwDsx3ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DSX3 Configuration table."
|
|
INDEX { dsx3LineNum }
|
|
::= { cwDsx3ConfigTable 1 }
|
|
|
|
CwDsx3ConfigEntry ::=
|
|
SEQUENCE {
|
|
dsx3LineNum Integer32,
|
|
cwDsx3LineType INTEGER,
|
|
cwDsx3LineCoding INTEGER,
|
|
cwDsx3LineLength INTEGER,
|
|
dsx3LineOOFCriteria INTEGER,
|
|
dsx3LineAIScBitsCheck INTEGER,
|
|
dsx3LineLoopbackCommand INTEGER,
|
|
dsx3LineRcvFEACValidation INTEGER,
|
|
dsx3LineXmtFEACCode INTEGER,
|
|
dsx3LineBERTEnable INTEGER,
|
|
dsx3LineBERTPattern INTEGER,
|
|
dsx3LineBERTResult INTEGER,
|
|
dsx3BERTResultClrButton INTEGER,
|
|
dsx3TrailTraceOption INTEGER,
|
|
dsx3TxTrailTrace DisplayString,
|
|
dsx3RxTrailTrace DisplayString,
|
|
dsx3TxTimingMarker INTEGER,
|
|
dsx3RxTimingMarker INTEGER,
|
|
dsx3TxPayloadType INTEGER,
|
|
dsx3RxPayloadType INTEGER,
|
|
dsx3TxTumf Integer32,
|
|
dsx3RxTumf Integer32,
|
|
dsx3LineEnable INTEGER,
|
|
dsx3FarEndLoopbkLineNum INTEGER,
|
|
dsx3LineXmtClockSrc INTEGER,
|
|
dsx3FarEndLoopbkLineStatus Integer32,
|
|
dsx3LineEqualizer INTEGER,
|
|
dsx3NearEndLoopbkLineStatus Integer32,
|
|
dsx3SubRateEnable INTEGER,
|
|
dsx3DsuSelect INTEGER,
|
|
dsx3LineRate Integer32,
|
|
dsx3LineScrambleEnable INTEGER
|
|
}
|
|
|
|
dsx3LineNum OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the identifier of a DS3/E3
|
|
Interface on a managed device.
|
|
|
|
The range supported depends upon the type of
|
|
the card(controller card, service module).
|
|
|
|
For 1 port Card : Range is 1..1
|
|
Example : CESM-T3E3
|
|
|
|
For 2 Port Card : Range is 1..2
|
|
Example : PXM1-2T3E3.
|
|
|
|
For 3 Port Card : Range is 1..3
|
|
Example: SRM-3T3"
|
|
|
|
::= { cwDsx3ConfigEntry 1 }
|
|
|
|
cwDsx3LineType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dsx3CbitParity (1),
|
|
g832-g804 (2),
|
|
dsx3M23 (3),
|
|
g751 (4),
|
|
dsx3Unframed (5),
|
|
e3Unframed (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the variety of DS3 C-bit
|
|
or E3 application implementing this interface.
|
|
The type of interface affects the interpretation
|
|
of the usage and error statistics. The rate of DS3
|
|
is 44.736 Mbps and E3 is 34.368 Mbps.
|
|
|
|
The values, in sequence, describe:
|
|
|
|
TITLE: SPECIFICATION:
|
|
|
|
dsx3CbitParity ANSI T1.107a-1990 [9a]
|
|
g832-g804 ITU-T G.832, G.804
|
|
dsx3M23 ANSI T1.107-1988 [9]
|
|
g751 ITU-T G.751
|
|
CESM-T3 supports only ds3Unframed linetype.
|
|
CESM-E3 supports only e3Unframed linetype."
|
|
::= { cwDsx3ConfigEntry 2 }
|
|
|
|
cwDsx3LineCoding OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dsx3B3ZS (1),
|
|
e3HDB3 (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable describes the variety of Zero Code
|
|
Suppression used on this interface, which in turn
|
|
affects a number of its characteristics.
|
|
|
|
dsx3B3ZS and e3HDB3 refer to the use of specified
|
|
patterns of normal bits and bipolar violations
|
|
which are used to replace sequences of zero bits
|
|
of a specified length.
|
|
|
|
dsx3B3ZS(1) : Bipolar 3-Zero Substitution(B3ZS) suppression.
|
|
e3HDB3 (2) : High-Density Bipolar 3(HDB3) suppression."
|
|
::= { cwDsx3ConfigEntry 3 }
|
|
|
|
cwDsx3LineLength OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lessThan225(1),
|
|
moreThan225(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the length of the
|
|
DS3 Line. This object provides information
|
|
for line build out circuitry if it exists
|
|
and can use this object to adjust the
|
|
line build out."
|
|
::= { cwDsx3ConfigEntry 4 }
|
|
|
|
dsx3LineOOFCriteria OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fBits3Of8 (1),
|
|
fBits3Of16 (2),
|
|
notApplicable(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the out of frame decision
|
|
criteria.
|
|
OOF is declared when errors are detected in the
|
|
framing octets for four consecuitive frames.
|
|
|
|
fBits3Of8(1) : an OOF condition is declared if at
|
|
least 3 of 8 framing bits are in error.
|
|
|
|
fBits3Of16(2): an OOF is declared if 3 of 16 framing
|
|
bits are found to be in error.
|
|
notApplicable(3) : used in case where it is not
|
|
applicable. This value can not be set.
|
|
|
|
This object is not applicable when cwDsx3LineType is
|
|
set to g832-g804(2) or g751(4).
|
|
This object is not applicable for CESM-T3/E3"
|
|
::= { cwDsx3ConfigEntry 5 }
|
|
|
|
dsx3LineAIScBitsCheck OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
checkCbits(1),
|
|
ignorebits(2),
|
|
notApplicable(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If check C-Bits options is chosen then AIS is declared
|
|
when 1010 pattern is found and C-Bits are all zero.
|
|
In the other case an AIS condition is declared when the
|
|
AIS pattern 1010... is detected irrespective of the state
|
|
of the C Bits.
|
|
This object does not apply to the E3 interface.
|
|
The value notApplicable(3) is used in case of interfaces
|
|
where this object is not applicable.
|
|
|
|
This object is not applicable for CESM-T3/E3."
|
|
::= { cwDsx3ConfigEntry 6 }
|
|
|
|
dsx3LineLoopbackCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dsx3NoLoop(1),
|
|
dsx3RemoteLineLoop(2),
|
|
dsx3LocalLineLoop(3),
|
|
dsx3InbndLocalLoopback(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents the loopback configuration
|
|
of the DS3/E3 interface.
|
|
The values mean:
|
|
dsx3NoLoop
|
|
Not in the loopback state. A device that is
|
|
not capable of performing a loopback on
|
|
the interface shall always return this as
|
|
it's value.
|
|
dsx3RemoteLineLoop
|
|
Near End loops back Remote data
|
|
dsx3LocalLineLoop
|
|
Near End loops back Local data(outbound).
|
|
dsx3InboundLoopback
|
|
Near End in bound loopback Local data(inbound)."
|
|
::= { cwDsx3ConfigEntry 7 }
|
|
|
|
dsx3LineRcvFEACValidation OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
fFEACCodes4Of5 (1),
|
|
fFEACCodes8Of10 (2),
|
|
fFEACCodesDisable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry specifies the FEAC code validation criteria.
|
|
fFEACCodes4Of5(1) : a valid FEAC code is declared if
|
|
4 of 5 codes match.
|
|
fFEACCodes8Of10(2): a valid FEAC code is declared if
|
|
8 of 10 codes match.
|
|
|
|
fFEACCodesDisable(3) : Do not respond to any valid FEAC code.
|
|
This object is not applicable to E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { cwDsx3ConfigEntry 8 }
|
|
|
|
dsx3LineXmtFEACCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dsx3SendNoCode(1),
|
|
dsx3SendLineCode(2),
|
|
dsx3SendPayloadCode(3),
|
|
dsx3SendResetCode(4),
|
|
dsx3SendDS1LoopCode(5),
|
|
dsx3SendTestPattern(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates what bit-oriented code to transmit
|
|
over the far-end alarm and control (FEAC) channel.
|
|
|
|
The values mean:
|
|
|
|
dsx3SendNoCode
|
|
sending looped or normal data
|
|
dsx3SendLineCode
|
|
sending a request for a line loopback
|
|
dsx3SendPayloadCode
|
|
sending a request for a payload loopback
|
|
(i.e., all DS1/E1s in a DS3/E3 frame)
|
|
dsx3SendResetCode
|
|
sending a loopback deactivation request.
|
|
dsx3SendDS1LoopCode
|
|
sending a request to put part of DS1/E1 within
|
|
T3/E3 respectively into loopback.
|
|
dsx3SendTestPattern
|
|
sending a test pattern.
|
|
This object is not applicable for CESM-T3/E3"
|
|
::= { cwDsx3ConfigEntry 9 }
|
|
|
|
dsx3LineBERTEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables/disables the BERT function on
|
|
an interface.
|
|
|
|
The possible values are :
|
|
disabled(1): disables port BERT functionality
|
|
enabled (2): enables port BERT functionality.
|
|
value specified in dsx3LineBERTPattern
|
|
is transmitted over the interface.
|
|
The far end may be looped back and the
|
|
test pattern verified."
|
|
::= { cwDsx3ConfigEntry 10 }
|
|
|
|
dsx3LineBERTPattern OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allZero(1),
|
|
allOnes(2),
|
|
alternateOneZero(3),
|
|
doubleOneZero(4),
|
|
userOneWord(5),
|
|
userTwoWords(6),
|
|
userThreeWords(7),
|
|
userFourWords(8),
|
|
pattern2p15minus1(9),
|
|
pattern2p20minus1(10),
|
|
pattern2p23minus1(11)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the test bit pattern to be
|
|
used for BERT.
|
|
|
|
The possible values are :
|
|
|
|
Repetitive Patterns
|
|
|
|
allZero(1): All Zeroes(Continuous spaces). This is
|
|
repeating pattern of zeros(...000...).
|
|
The use of this pattern is to test and verify
|
|
that the ones density policing mechanism is
|
|
functioning properly. This pattern must be
|
|
used in circuits optioned for B8ZS.
|
|
|
|
allOnes(2): All Ones(Continuous Marks). This is repeating
|
|
pattern of ones(...1111...). This provides
|
|
testing of maximum power level requirements.
|
|
The all one pattern test causes the repeater
|
|
to consume the maximum amount of power.
|
|
If there is insufficient DC span power then the
|
|
repeater may begin to fail.
|
|
Typically this pattern is used for a simple
|
|
continuity check. It may also be used to detect
|
|
the presence of unwanted loop in the network.
|
|
|
|
alternateOneZero(3): Alternate one/zero pattern(..1010..). This
|
|
pattern produces a 50% ones density. It is
|
|
used to stress the repeater's DC power
|
|
consumption.
|
|
|
|
doubleOneZero(4): Double alternate one/zero(..1100..).
|
|
|
|
userOneWord(5),
|
|
userTwoWords(6),
|
|
userThreeWords(7),
|
|
userFourWords(8),
|
|
pattern2p15minus1(9) :
|
|
This is the 2^15-1(32767 bit length)
|
|
pattern as specified in ITU O.151.
|
|
It has the maximum of 15(inverted) sequential zeros.
|
|
This sequence is primarily intended for
|
|
error and jitter measurements at bit
|
|
rates of 1544, 2048, 6312, 8448,
|
|
32064 and 44736 kbit/s.
|
|
|
|
pattern2p20minus1(10):
|
|
This is the 2^20-1(1048575 bits in length)
|
|
pattern specified in ITU O.153.It has
|
|
the maximum of 19(non-inverted) sequential
|
|
zeros. This pattern is primarily intended
|
|
for error measurements at bit rates up to
|
|
73kbit/s. This pattern stresses the
|
|
equalization and timing recovery circuitry
|
|
of line repeaters.
|
|
|
|
pattern2p23minus1(11):
|
|
This is the 2^23-1(1048575 bits in length) pattern."
|
|
::= { cwDsx3ConfigEntry 11 }
|
|
|
|
dsx3LineBERTResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bertFailed(1),
|
|
bertPassed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Result of BERT Test. The value in this object
|
|
is not applicable if dsx3LineBERTEnable is set to
|
|
disabled(1)."
|
|
::= { cwDsx3ConfigEntry 12 }
|
|
|
|
dsx3BERTResultClrButton OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
clear(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to clear(2) causes the BERT
|
|
result field to get cleared."
|
|
::= { cwDsx3ConfigEntry 13 }
|
|
|
|
--
|
|
-- The following are the E3 specific configuration parameters
|
|
--
|
|
|
|
dsx3TrailTraceOption OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used for enabling/disabling
|
|
G.832 Trail Trace. The trail trace is used to
|
|
repetitively transmit a trail access point identifier
|
|
so that a trail receiving terminal can verify its
|
|
continued connection to the intended transmitter.
|
|
It uses a 16-byte numbering format (see Rec E.164).
|
|
The first byte of the string is a frame start marker
|
|
and includes the result of a CRC-7 calculation over
|
|
the previous frame.
|
|
|
|
The value of this object is set to disable(1) in case
|
|
of cards where this feature is not supported.
|
|
|
|
This object is not applicable for FRSM-VHS and
|
|
CESM-T3/E3."
|
|
REFERENCE
|
|
"ITU-T G.832"
|
|
::= { cwDsx3ConfigEntry 14 }
|
|
|
|
dsx3TxTrailTrace OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..15))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used for specifying the
|
|
data to be used for G.832 Trail Trace ID/String.
|
|
This object is applicable only for E3 interfaces
|
|
with G.832 framing.
|
|
|
|
The trail trace ID is a 16 octet field that
|
|
contains 1 octet of CRC-7(first octet) and 15
|
|
octets of data.
|
|
|
|
The CRC-7 is automatically calculated by the
|
|
system(card supporting this feature).
|
|
|
|
The format of the value is:
|
|
Frame Start Marker Error(HEX): CRC-7
|
|
Bytes 2-6 (ASCII) [Byte 1-5 of this object]
|
|
Bytes 7-11 (ASCII) [Byte 6-10 of this object]
|
|
Bytes 12-16 (ASCII) [Byte 11-15 of this object]
|
|
|
|
This object is not applicable for FRSM-VHS and
|
|
CESM-T3/E3."
|
|
REFERENCE
|
|
"ITU-T G.832"
|
|
::= { cwDsx3ConfigEntry 15 }
|
|
|
|
dsx3RxTrailTrace OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..15))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received G.832 Trail Trace string.
|
|
The format of the value is:
|
|
First byte indicates CRC-7(frame start marker).
|
|
Bytes 2-6 (ASCII) [Byte 1-5 of this object]
|
|
Bytes 7-11 (ASCII) [Byte 6-10 of this object]
|
|
Bytes 12-16 (ASCII) [Byte 11-15 of this object]
|
|
The value of all zeroes indicates bad CRC-7.
|
|
|
|
This object is not applicable for FRSM-VHS and
|
|
CESM-T3/E3."
|
|
REFERENCE
|
|
"ITU-T G.832"
|
|
::= { cwDsx3ConfigEntry 16 }
|
|
|
|
dsx3TxTimingMarker OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
traceable (1),
|
|
untraceable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted timing marker bit in G.832 MA byte.
|
|
This object can be set to traceable(1) to indicate
|
|
that the timing source is traceable to a primary
|
|
reference clock and is otherwise set to untraceable(2).
|
|
|
|
This is always set to untraceable(2) in case of
|
|
card where this feature is not supported.
|
|
|
|
This feature is not supported in FRSM-VHS and
|
|
CESM-T3/E3."
|
|
REFERENCE
|
|
"ITU-T G.832"
|
|
::= { cwDsx3ConfigEntry 17 }
|
|
|
|
dsx3RxTimingMarker OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
traceable (1),
|
|
untraceable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received timing marker bit in G.832 MA byte.
|
|
This object can be set to traceable(1) to indicate
|
|
that the timing source is tracable to a primary
|
|
reference clock and is otherwise set to untraceable(2).
|
|
|
|
This is always set to untraceable(2) in case of
|
|
card where this feature is not supported.
|
|
|
|
This feature is not supported in FRSM-VHS and
|
|
CESM-T3/E3."
|
|
REFERENCE
|
|
"ITU-T G.832"
|
|
::= { cwDsx3ConfigEntry 18 }
|
|
|
|
dsx3TxPayloadType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unequipped (1),
|
|
equipped (2),
|
|
atm (3),
|
|
sdhtu12s (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the G.832 payload type
|
|
for transmit data.
|
|
|
|
The possible values are :
|
|
|
|
unequipped (1): not carrying any payload
|
|
equipped (2): Equipped,non-specific
|
|
atm (3): ATM
|
|
sdhtu12s (4): SDH Elements mapping
|
|
|
|
It is recommended that this object is not instantiated
|
|
in case of cards which does not support G.832 functionality.
|
|
|
|
This is not supported in FRSM-VHS and CESM-T3/E3"
|
|
REFERENCE
|
|
"ITU-T G.832 section 2.1.2."
|
|
DEFVAL { unequipped }
|
|
::= { cwDsx3ConfigEntry 19 }
|
|
|
|
dsx3RxPayloadType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unequipped (1),
|
|
equipped (2),
|
|
atm (3),
|
|
sdhtu12s (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received payload type field in G.832 byte
|
|
|
|
The possible values are :
|
|
|
|
unequipped (1): not carrying any payload
|
|
equipped (2): Equipped,non-specific
|
|
atm (3): ATM
|
|
sdhtu12s (4): SDH Elements mapping
|
|
|
|
It is recommended that this object is not instantiated
|
|
in case of cards which does not support G.832 functionality.
|
|
|
|
This is not supported in FRSM-VHS and CESM-T3/E3"
|
|
REFERENCE
|
|
"ITU-T G.832 section 2.1.2."
|
|
::= { cwDsx3ConfigEntry 20 }
|
|
|
|
dsx3TxTumf OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of
|
|
Tributary Multiframe Indicator(bits 6 and 7 of MA byte)
|
|
in case of TU-1xs mapping.
|
|
|
|
This is not supported in FRSM-VHS and CESM-T3/E3."
|
|
REFERENCE
|
|
"ITU-T G.832, section 3.4.3"
|
|
::= { cwDsx3ConfigEntry 21 }
|
|
|
|
dsx3RxTumf OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of
|
|
Tributary Multiframe Indicator(bits 6 and 7 of MA byte)
|
|
in case of TU-1xs mapping.
|
|
|
|
This object is not supported in FRSM-VHS
|
|
and CESM-T3/E3."
|
|
REFERENCE
|
|
"ITU-T G.832, section 3.4.3"
|
|
::= { cwDsx3ConfigEntry 22 }
|
|
|
|
dsx3LineEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2),
|
|
modify (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used for enabling/disabling an interface
|
|
and modifying the interface configuration.
|
|
|
|
The possible values are:
|
|
|
|
disable (1): Interface is administratively down
|
|
enable (2): Interface is administratively up.
|
|
modify (3): Used for modifying the parameters
|
|
of an interface that has been already
|
|
enabled(administratively up).
|
|
To modify the parameters of this table, the value
|
|
of this object must be set to enable(2) or modify(3)."
|
|
::= { cwDsx3ConfigEntry 23 }
|
|
|
|
dsx3FarEndLoopbkLineNum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ds1line1(1),
|
|
ds1line2(2),
|
|
ds1line3(3),
|
|
ds1line4(4),
|
|
ds1line5(5),
|
|
ds1line6(6),
|
|
ds1line7(7),
|
|
ds1line8(8),
|
|
ds1line9(9),
|
|
ds1line10(10),
|
|
ds1line11(11),
|
|
ds1line12(12),
|
|
ds1line13(13),
|
|
ds1line14(14),
|
|
ds1line15(15),
|
|
ds1line16(16),
|
|
ds1line17(17),
|
|
ds1line18(18),
|
|
ds1line19(19),
|
|
ds1line20(20),
|
|
ds1line21(21),
|
|
ds1line22(22),
|
|
ds1line23(23),
|
|
ds1line24(24),
|
|
ds1line25(25),
|
|
ds1line26(26),
|
|
ds1line27(27),
|
|
ds1line28(28),
|
|
ds1line29(29),
|
|
ds3line(30)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify which DS1 or DS3 line in the far-end for the
|
|
loopback testing.
|
|
For CESM-T3/E3, only ds3line(30) is valid."
|
|
::= { cwDsx3ConfigEntry 24 }
|
|
|
|
dsx3LineXmtClockSrc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
backplaneClk (1),
|
|
recoverClk (2),
|
|
localClk (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source of the transmit clock.
|
|
|
|
backplaneClk(2) : clock source is from the backplane.
|
|
recoverClk (3) : clock source is derived from another
|
|
t3 interface.
|
|
localClk (4) : clock source is from a local
|
|
oscillator on the card"
|
|
::= { cwDsx3ConfigEntry 25 }
|
|
|
|
dsx3FarEndLoopbkLineStatus OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a bitmap of the DSX3 FarEnd line
|
|
loopback status bits
|
|
|
|
Bit Position Loopback indicator
|
|
----------- -----
|
|
1 DS1 Line 1
|
|
2 DS1 Line 2
|
|
3 DS1 Line 3
|
|
4 DS1 Line 4
|
|
5 DS1 Line 5
|
|
6 DS1 Line 6
|
|
7 DS1 Line 7
|
|
8 DS1 Line 8
|
|
9 DS1 Line 9
|
|
10 DS1 Line 10
|
|
11 DS1 Line 11
|
|
12 DS1 Line 12
|
|
...
|
|
...
|
|
...
|
|
28 DS1 Line 28
|
|
29 all DS1 Lines
|
|
30 DSX3
|
|
For CESM-T3/E3, only DSX3 bit (bit 30) is valid."
|
|
::= { cwDsx3ConfigEntry 26 }
|
|
|
|
|
|
dsx3LineEqualizer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
intrnlequalizer(1),
|
|
extequalizer(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the internal equalizer
|
|
is being used or bypassed. Set this value depending on
|
|
the line equipment to which the receiver is attached.
|
|
|
|
intrnlequalizer(1): Use internal line equalizer
|
|
extequalizer(2) : Use External equalizer or bypass internal
|
|
equalizer."
|
|
::= { cwDsx3ConfigEntry 27 }
|
|
|
|
dsx3NearEndLoopbkLineStatus OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a bitmap of the DSX3 NearEnd line
|
|
loopback status bits
|
|
BitPosition Loopback indicator
|
|
----------- -----
|
|
1 DS1 Line 1
|
|
2 DS1 Line 2
|
|
3 DS1 Line 3
|
|
4 DS1 Line 4
|
|
5 DS1 Line 5
|
|
6 DS1 Line 6
|
|
7 DS1 Line 7
|
|
8 DS1 Line 8
|
|
9 DS1 Line 9
|
|
10 DS1 Line 10
|
|
11 DS1 Line 11
|
|
12 DS1 Line 12
|
|
...
|
|
...
|
|
...
|
|
28 DS1 Line 28
|
|
29 DS1 Line 29
|
|
30 DSX3
|
|
|
|
For CESM-T3/E3, only DSX3 bit (bit 30) is valid."
|
|
::= { cwDsx3ConfigEntry 28 }
|
|
|
|
dsx3SubRateEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable controls whether the DS3 subrates are
|
|
enabled or not. The DS3 subrate is part of
|
|
DSU functionality.
|
|
This object is currently supported only in FRSM-VHS
|
|
cards.
|
|
|
|
It is recommended that this object is not instantiated
|
|
in case of cards which does not support DSU functionality."
|
|
DEFVAL { disable }
|
|
::= { cwDsx3ConfigEntry 29 }
|
|
|
|
dsx3DsuSelect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dl3100Mode(1),
|
|
adcKentroxMode(2),
|
|
larsCom(3),
|
|
clearChannel(4),
|
|
dsuAlgorithm2(5),
|
|
dsuAlgorithm3(6),
|
|
dsuAlgorithm4(7),
|
|
dsuAlgorithm5(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The dsx3DsuSelect variable controls the type of DSU mode
|
|
to be selected. The 'dsx3SubRateEnable' has to be set to
|
|
'enable' before selecting the mode in 'dsx3DsuSelect'.
|
|
|
|
The possible values for this are :
|
|
|
|
dl3100Mode - Indicates compatibility with Digital Link Inc's
|
|
DL3100 DSU mode of operation. This mode permits
|
|
line rates to be in multiples of 300 Kbps.
|
|
adcKentroxMode - Indicates compatibility with ADC Kentrox's DSU.
|
|
This mode permits line rates to be in multiples
|
|
of 500 Kbps.
|
|
larsCom - Indicates compatability with LarsCom DSU.
|
|
clearChannel - Indicates the standard G.751 framing format
|
|
(12 overhead bits and 1524 data bits in an E3
|
|
frame).This option is supported only in FRSM-2E3.
|
|
dsuAlgorithm1 - dsuAlgorith4 - Presently this is not used in any of
|
|
the cards.
|
|
This object is supported only in FRSM-VHS cards.
|
|
|
|
It is recommended that this object is not instantiated
|
|
in case of cards which does not support DSU functionality."
|
|
DEFVAL { dl3100Mode }
|
|
::= { cwDsx3ConfigEntry 30 }
|
|
|
|
dsx3LineRate OBJECT-TYPE
|
|
SYNTAX Integer32 (300..44736)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired line rate when 'dsx3SubRateEnable' is enabled.
|
|
If dsx3DsuSelect is set to 'dl3100Mode', the line rate can
|
|
be configured in steps of 300 Kbps.
|
|
If dsx3DsuSelect is set to 'adcKentroxMode', the line rate can
|
|
be configured in steps of 500 Kbps.
|
|
|
|
This object is supported only in FRSM-VHS cards.
|
|
|
|
It is recommended that this object is not instantiated
|
|
in case of cards which does not support DSU functionality."
|
|
::= { cwDsx3ConfigEntry 31 }
|
|
|
|
dsx3LineScrambleEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable turns the scrambling feature ON/OFF
|
|
The scrambling is a technique that enables framing
|
|
to be maintained on certain medium-speed edge and
|
|
trunk interfaces.
|
|
|
|
This object is ONLY applicable for FRSM-2T3/E3."
|
|
::= { cwDsx3ConfigEntry 32 }
|
|
|
|
dsx3LineNumOfValidEntries OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of DSX3 configuration entries (regardless
|
|
of their current configuration) in the cwDsx3ConfigTable."
|
|
::= { dsx3Config 2 }
|
|
|
|
-- --------------------------------------------------------------
|
|
--
|
|
-- dsx3AlarmConfig group
|
|
--
|
|
-- --------------------------------------------------------------
|
|
dsx3AlarmConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx3AlarmConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSX3 interface alarm configuration table. This table contains
|
|
the parameters associated with detecting and declaring alarms for
|
|
the interface. The parameters include severity of alarm, alarm
|
|
integration parameters and 15 minute and 24 hour thresholds.
|
|
The number of rows is given by dsx3LineNumOfValidEntries."
|
|
::= { dsx3AlarmConfig 1 }
|
|
|
|
dsx3AlarmConfigEntry OBJECT-TYPE
|
|
SYNTAX Dsx3AlarmConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DSX3 Alarm Configuration table.
|
|
|
|
Thresholds may be configured for:
|
|
|
|
Line Code Violations (LCV),
|
|
LineErrored Seconds (LES),
|
|
Line Severely Errored Seconds (LSES),
|
|
P-bit Coding Violations (PCV),
|
|
P-bit Errored Seconds (PES),
|
|
P-bit Severely Errored Seconds(PSES),
|
|
Severely Errored Seconds (SES),
|
|
Severely Errored Framing Seconds(SEFS),
|
|
Unavailable Seconds (UAS),
|
|
C-bit coding violations (CCV),
|
|
C-bit errored seconds (CES),
|
|
C-bit errored seconds (CSES).
|
|
Once these thresholds are exceeded, minor or major alarms
|
|
are raised. Please refer to RFC2496 for descriptions of these
|
|
errors."
|
|
INDEX { dsx3LineNum }
|
|
::= { dsx3AlarmConfigTable 1 }
|
|
|
|
Dsx3AlarmConfigEntry ::=
|
|
SEQUENCE {
|
|
dsx3RedSeverity INTEGER,
|
|
dsx3RAISeverity INTEGER,
|
|
dsx3NEAlarmUpCount Integer32,
|
|
dsx3NEAlarmDownCount Integer32,
|
|
dsx3NEAlarmThreshold Integer32,
|
|
dsx3FEAlarmUpCount Integer32,
|
|
dsx3FEAlarmDownCount Integer32,
|
|
dsx3FEAlarmThreshold Integer32,
|
|
dsx3StatisticalAlarmSeverity INTEGER,
|
|
dsx3LCV15MinThreshold Integer32,
|
|
dsx3LCV24HrThreshold Integer32,
|
|
dsx3LES15MinThreshold Integer32,
|
|
dsx3LES24HrThreshold Integer32,
|
|
dsx3LSES15MinThreshold Integer32,
|
|
dsx3LSES24HrThreshold Integer32,
|
|
dsx3PCV15MinThreshold Integer32,
|
|
dsx3PCV24HrThreshold Integer32,
|
|
dsx3PES15MinThreshold Integer32,
|
|
dsx3PES24HrThreshold Integer32,
|
|
dsx3PSES15MinThreshold Integer32,
|
|
dsx3PSES24HrThreshold Integer32,
|
|
dsx3SEFS15MinThreshold Integer32,
|
|
dsx3SEFS24HrThreshold Integer32,
|
|
dsx3AISS15MinThreshold Integer32,
|
|
dsx3AISS24HrThreshold Integer32,
|
|
dsx3UAS15MinThreshold Integer32,
|
|
dsx3UAS24HrThreshold Integer32,
|
|
dsx3E3BIP8CV15MinThreshold Integer32,
|
|
dsx3E3BIP8CV24HrThreshold Integer32,
|
|
dsx3E3BIP8ES15MinThreshold Integer32,
|
|
dsx3E3BIP8ES24HrThreshold Integer32,
|
|
dsx3E3BIP8SES15MinThreshold Integer32,
|
|
dsx3E3BIP8SES24HrThreshold Integer32,
|
|
dsx3CCV15MinThreshold Integer32,
|
|
dsx3CCV24HrThreshold Integer32,
|
|
dsx3CES15MinThreshold Integer32,
|
|
dsx3CES24HrThreshold Integer32,
|
|
dsx3CSES15MinThreshold Integer32,
|
|
dsx3CSES24HrThreshold Integer32
|
|
}
|
|
|
|
dsx3RedSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minor(1),
|
|
major(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to setup the severity of RED
|
|
alarm. So when LOS/LOF alarm is detected the card will
|
|
send the alarm with appropriate severity status.
|
|
A major alarm will cause audible notification
|
|
and the MAJOR ALARM LED will be turned ON.
|
|
A minor alarm will just turn on the MINOR ALARM LED.
|
|
LOF detection is not applicable for CESM-8T3/E3.
|
|
"
|
|
::= { dsx3AlarmConfigEntry 1 }
|
|
|
|
dsx3RAISeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minor(1),
|
|
major(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to setup the severity of RAI
|
|
alarm. So when RAI alarm is detected the card will
|
|
send the alarm with appropriate severity status.
|
|
A major alarm will cause the audible notification
|
|
and the MAJOR ALARM LED will be turned ON.
|
|
A minor alarm will just turn on the MINOR ALARM LED.
|
|
This is not applicable for CESM-T3/E3.
|
|
"
|
|
::= { dsx3AlarmConfigEntry 2 }
|
|
|
|
dsx3NEAlarmUpCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter specifies the increment to the
|
|
Near End alarm integration counters. The local
|
|
alarms are LOS and LOF. The Default value is 6
|
|
and the integration counter is incremented by
|
|
this value every 10 ms while the alarm persists.
|
|
The counter is decremented by the value of
|
|
dsx3NEAlarmDnCount while there is no alarm
|
|
(the counter does not decrement below zero).
|
|
When the integration counter exceeds
|
|
dsx3NEAlarmThreshold an Alarm of the severity
|
|
specified for the particular NE alarm is declared.
|
|
|
|
LOF detection is not applicable for CESM-T3/E3"
|
|
::= { dsx3AlarmConfigEntry 3 }
|
|
|
|
dsx3NEAlarmDownCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter specifies the decrement to the
|
|
Near End alarm integration counters. The local
|
|
alarms are LOS and LOF. The Default value is 1 and
|
|
the integration counter is decremented by this value
|
|
every 10 ms while no alarm persists. The counter is
|
|
incremented by the value of dsx3NEAlarmUpCount
|
|
while there is no alarm (the counter does not decrement below
|
|
zero). When the integration counter reaches zero any Alarm
|
|
previously declared is removed.
|
|
|
|
LOF detection is not applicable for CESM-T3/E3"
|
|
::= { dsx3AlarmConfigEntry 4 }
|
|
|
|
dsx3NEAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value that
|
|
the alarm integration counter must reach for an near end
|
|
Alarm to be declared. If the up count is 6, the down count
|
|
is 1 and the threshold 1500, an Alarm is integrated in
|
|
2.5 sec and removed in 15 seconds."
|
|
::= { dsx3AlarmConfigEntry 5 }
|
|
|
|
dsx3FEAlarmUpCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter specifies the increment to the
|
|
Far End alarm integration counters. The local alarms
|
|
are RAI and AIS. The Default value is 6 and the
|
|
integration counter is incremented by this value every
|
|
10 ms while the alarm persists. The counter is decremented
|
|
by the value of dsx3FEAlarmDnCount while there is no alarm
|
|
(the counter does not decrement below zero).
|
|
When the integration counter exceeds dsx3FEAlarmThreshold
|
|
an Alarm of the severity specified for the particular far end
|
|
alarm is declared.
|
|
|
|
This object is not applicable for CESM-T3/E3. "
|
|
::= { dsx3AlarmConfigEntry 6 }
|
|
|
|
dsx3FEAlarmDownCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter specifies the decrement to the
|
|
Far End alarm integration counters. The local alarms
|
|
are AIS and RAI. The Default value is 1. The integration
|
|
counter is decremented by this value every 10 ms
|
|
(till zero), while no alarm persists. The counter is
|
|
incremented by the value of dsx3FEAlarmUpCount
|
|
while there is no alarm. When the integration counter
|
|
decrements to zero any previously declared Alarm is removed.
|
|
|
|
This object is not applicable for CESM-T3/E3. "
|
|
::= { dsx3AlarmConfigEntry 7 }
|
|
|
|
dsx3FEAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value that
|
|
the alarm integration counter must reach for an far end
|
|
Alarm to be declared. If the up count is 6, the down count
|
|
is 1 and the threshold 1500, an Alarm is integrated in
|
|
2.5 sec and removed in 15 seconds.
|
|
This object is not applicable for CESM-T3/E3. "
|
|
::= { dsx3AlarmConfigEntry 8 }
|
|
|
|
dsx3StatisticalAlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minor(1),
|
|
major(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to setup the severity of
|
|
any of the Statistical alarms. So when a
|
|
Statistical Counter exceeds its specified threshold
|
|
the card will send the alarm with appropriate
|
|
severity. A major alarm will cause the audible notification
|
|
and the MAJOR ALARM LED will be turned ON.
|
|
A minor alarm will just turn on the MINOR ALARM LED."
|
|
::= { dsx3AlarmConfigEntry 9 }
|
|
|
|
dsx3LCV15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a 15 minute window causes
|
|
a statistical alarm to be declared."
|
|
::= { dsx3AlarmConfigEntry 10 }
|
|
|
|
dsx3LCV24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a sliding 24 hour window causes
|
|
a statistical alarm to be declared. The threshold is
|
|
checked every 15 minutes for the preceding 24 hour interval"
|
|
::= { dsx3AlarmConfigEntry 11 }
|
|
|
|
dsx3LES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a 15 minute window causes
|
|
a statistical alarm to be declared."
|
|
::= { dsx3AlarmConfigEntry 12 }
|
|
|
|
dsx3LES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a sliding 24 hour window causes
|
|
a statistical alarm to be declared. The threshold is
|
|
checked every 15 minutes for the preceding 24 hour interval"
|
|
::= { dsx3AlarmConfigEntry 13 }
|
|
|
|
dsx3LSES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a 15 minute window causes
|
|
a statistical alarm to be declared."
|
|
::= { dsx3AlarmConfigEntry 14 }
|
|
|
|
dsx3LSES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a sliding 24 hour window causes
|
|
a statistical alarm to be declared. The threshold is
|
|
checked every 15 minutes for the preceding 24 hour interval"
|
|
::= { dsx3AlarmConfigEntry 15 }
|
|
|
|
dsx3PCV15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared.
|
|
This object is not supported in CESM-T3/E3.
|
|
This object is not applicable for E3 interface."
|
|
::= { dsx3AlarmConfigEntry 16 }
|
|
|
|
dsx3PCV24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval
|
|
This object is not supported in CESM-T3/E3.
|
|
This object is not applicable for E3 interface."
|
|
::= { dsx3AlarmConfigEntry 17 }
|
|
|
|
dsx3PES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared.
|
|
This object is not supported in CESM-T3/E3.
|
|
This object is not applicable for E3 interface."
|
|
::= { dsx3AlarmConfigEntry 18 }
|
|
|
|
dsx3PES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval.
|
|
This object is not supported in CESM-T3/E3
|
|
This object is not applicable for E3 interface."
|
|
::= { dsx3AlarmConfigEntry 19 }
|
|
|
|
dsx3PSES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a 15 minute window causes
|
|
a statistical alarm to be declared.
|
|
|
|
This object does not apply to the E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 20 }
|
|
|
|
dsx3PSES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval.
|
|
|
|
This object is not applicable for E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 21 }
|
|
|
|
dsx3SEFS15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a 15 minute window causes
|
|
a statistical alarm to be declared.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmConfigEntry 22 }
|
|
|
|
dsx3SEFS24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a sliding 24 hour window causes
|
|
a statistical alarm to be declared. The threshold is
|
|
checked every 15 minutes for the preceding 24 hour interval.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmConfigEntry 23 }
|
|
|
|
dsx3AISS15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a 15 minute window causes
|
|
a statistical alarm to be declared.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmConfigEntry 24 }
|
|
|
|
dsx3AISS24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a sliding 24 hour window causes
|
|
a statistical alarm to be declared. The threshold is
|
|
checked every 15 minutes for the preceding 24 hour interval
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmConfigEntry 25 }
|
|
|
|
dsx3UAS15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a 15 minute window causes
|
|
a statistical alarm to be declared."
|
|
::= { dsx3AlarmConfigEntry 26 }
|
|
|
|
dsx3UAS24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a sliding 24 hour window causes
|
|
a statistical alarm to be declared. The threshold is
|
|
checked every 15 minutes for the preceding 24 hour interval"
|
|
::= { dsx3AlarmConfigEntry 27 }
|
|
|
|
dsx3E3BIP8CV15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G.832 BIP-8 error monitoring byte. 15 minute
|
|
threshold value.
|
|
This has no significance to E3 with G.751 framing
|
|
which is used in FRSM-VHS
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 28 }
|
|
|
|
dsx3E3BIP8CV24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G.832 BIP-8 error monitoring byte. 24 hour
|
|
threshold value.
|
|
|
|
This has no significance to E3 with G.751 framing
|
|
which is used in FRSM-VHS.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 29 }
|
|
|
|
dsx3E3BIP8ES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G.832 BIP-8 error monitoring byte. 15 minute
|
|
threshold value.
|
|
|
|
This has no significance to E3 with G.751 framing
|
|
which is used in FRSM-VHS.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 30 }
|
|
|
|
dsx3E3BIP8ES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G.832 BIP-8 error monitoring byte. 24 hour
|
|
threshold value.
|
|
This has no significance to E3 with G.751 framing
|
|
which is used in FRSM-VHS
|
|
This object is not supported in CESM-T3/E3
|
|
"
|
|
::= { dsx3AlarmConfigEntry 31 }
|
|
|
|
dsx3E3BIP8SES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G.832 BIP-8 error monitoring byte. 15 minute
|
|
threshold value.
|
|
This has no significance to E3 with G.751 framing
|
|
which is used in FRSM-VHS
|
|
This object is not supported in CESM-T3/E3
|
|
"
|
|
::= { dsx3AlarmConfigEntry 32 }
|
|
|
|
dsx3E3BIP8SES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G.832 BIP-8 error monitoring byte. 24 hour
|
|
threshold value.
|
|
This has no significance to E3 with G.751 framing
|
|
which is used in FRSM-VHS
|
|
This object is not supported in CESM-T3/E3
|
|
"
|
|
::= { dsx3AlarmConfigEntry 33 }
|
|
|
|
dsx3CCV15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared.
|
|
|
|
This object is not applicable for E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 34 }
|
|
|
|
dsx3CCV24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval
|
|
|
|
This object is not applicable for E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 35 }
|
|
|
|
dsx3CES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared.
|
|
|
|
This object is not applicable for E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 36 }
|
|
|
|
dsx3CES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
|
|
This object is not applicable for E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 37 }
|
|
|
|
dsx3CSES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a 15 minute window causes
|
|
a statistical alarm to be declared.
|
|
|
|
This object is not applicable for E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 38 }
|
|
|
|
dsx3CSES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the value
|
|
which when exceeded in a sliding 24 hour window causes
|
|
a statistical alarm to be declared.
|
|
|
|
This object is not applicable for E3 interface.
|
|
|
|
This object is not supported in CESM-T3/E3."
|
|
::= { dsx3AlarmConfigEntry 39 }
|
|
|
|
-- --------------------------------------------------------------
|
|
--
|
|
-- dsx3Alarm group
|
|
-- This group contains dsx3 Alarm table
|
|
--
|
|
-- --------------------------------------------------------------
|
|
dsx3AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx3AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSX3 interface alarm table. This table
|
|
contains the performance statistics and Error Events
|
|
based on 15 minute and/or 24 hour interval.
|
|
|
|
Performance Parameters:
|
|
LES : Line Errored Seconds
|
|
PES : P-bit Errored Seconds
|
|
PSES : P-bit Severely Errored Seconds
|
|
CES : C-bit Errored Seconds
|
|
CSES : C-bit Severely Errored Seconds
|
|
SEFS : Severely Errored Framing Seconds
|
|
UAS : Unavailable Seconds
|
|
|
|
Error Events:
|
|
BPV : Bipolar Violation
|
|
EXZ : Excessive Zeros
|
|
LCV : Line Coding Violation
|
|
PCV : P-bit Coding Violation
|
|
CCV : C-bit Coding Violation."
|
|
REFERENCE
|
|
"RFC 2496, Section 2.4.1 and 2.4.2"
|
|
::= { dsx3Alarm 1 }
|
|
|
|
dsx3AlarmEntry OBJECT-TYPE
|
|
SYNTAX Dsx3AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DSX3 Alarm table. The bucket
|
|
statistics(15 minute and 24 hour interval statistics)
|
|
are gathered for each ds3/e3 interface.
|
|
Any entry is created automatically when ds3 interface
|
|
is created."
|
|
INDEX { dsx3LineNum }
|
|
::= { dsx3AlarmTable 1 }
|
|
|
|
Dsx3AlarmEntry ::=
|
|
SEQUENCE {
|
|
dsx3LineAlarmState Integer32,
|
|
dsx3LineStatisticalAlarmState Integer32,
|
|
dsx3LCVCurrent Counter32,
|
|
dsx3LCV15MinBucket Counter32,
|
|
dsx3LCV24HrBucket Counter32,
|
|
dsx3LESCurrent Counter32,
|
|
dsx3LES15MinBucket Counter32,
|
|
dsx3LES24HrBucket Counter32,
|
|
dsx3LSESCurrent Counter32,
|
|
dsx3LSES15MinBucket Counter32,
|
|
dsx3LSES24HrBucket Counter32,
|
|
dsx3PCVCurrent Counter32,
|
|
dsx3PCV15MinBucket Counter32,
|
|
dsx3PCV24HrBucket Counter32,
|
|
dsx3PESCurrent Counter32,
|
|
dsx3PES15MinBucket Counter32,
|
|
dsx3PES24HrBucket Counter32,
|
|
dsx3PSESCurrent Counter32,
|
|
dsx3PSES15MinBucket Counter32,
|
|
dsx3PSES24HrBucket Counter32,
|
|
dsx3SEFSCurrent Counter32,
|
|
dsx3SEFS15MinBucket Counter32,
|
|
dsx3SEFS24HrBucket Counter32,
|
|
dsx3AISSCurrent Counter32,
|
|
dsx3AISS15MinBucket Counter32,
|
|
dsx3AISS24HrBucket Counter32,
|
|
dsx3UASCurrent Counter32,
|
|
dsx3UAS15MinBucket Counter32,
|
|
dsx3UAS24HrBucket Counter32,
|
|
dsx3PercentLcvEFS Integer32,
|
|
dsx3E3BIP8CVCurrent Counter32,
|
|
dsx3E3BIP8CV15MinBucket Counter32,
|
|
dsx3E3BIP8CV24HrBucket Counter32,
|
|
dsx3E3BIP8ESCurrent Counter32,
|
|
dsx3E3BIP8ES15MinBucket Counter32,
|
|
dsx3E3BIP8ES24HrBucket Counter32,
|
|
dsx3E3BIP8SESCurrent Counter32,
|
|
dsx3E3BIP8SES15MinBucket Counter32,
|
|
dsx3E3BIP8SES24HrBucket Counter32,
|
|
dsx3LineAlarmClrButton INTEGER,
|
|
dsx3CCVCurrent Counter32,
|
|
dsx3CCV15MinBucket Counter32,
|
|
dsx3CCV24HrBucket Counter32,
|
|
dsx3CESCurrent Counter32,
|
|
dsx3CES15MinBucket Counter32,
|
|
dsx3CES24HrBucket Counter32,
|
|
dsx3CSESCurrent Counter32,
|
|
dsx3CSES15MinBucket Counter32,
|
|
dsx3CSES24HrBucket Counter32
|
|
|
|
}
|
|
|
|
dsx3LineAlarmState OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is a bitmap of the DSX3 Line ALarms
|
|
on the card. A value of zero indicates no alarms.
|
|
|
|
Itemized below are the individual bits:
|
|
BitPosition Alarm
|
|
----------- -----
|
|
0 Receiving RAI
|
|
1 Transmitting RAI
|
|
2 Receiving AIS
|
|
3 Transmitting AIS
|
|
4 Receiving OOF
|
|
5 Receiving LOS
|
|
6 Near End Local Loopback in effect
|
|
7 Near End Remote Loopback in effect
|
|
8 Receiving test pattern
|
|
9 Receive LCD
|
|
10 Receiving C-bit Parity pattern
|
|
"
|
|
DEFVAL {0}
|
|
::= { dsx3AlarmEntry 1 }
|
|
|
|
dsx3LineStatisticalAlarmState OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a bitmap of the DSX3 Line Statistical
|
|
Alarms on the card. Zero indicates no alarms.
|
|
|
|
Itemized below are the individual alarm bits:
|
|
|
|
BitPosition Alarm
|
|
----------- -----
|
|
0 LCV 15 minute threshold exceeded
|
|
1 LCV 24 hour threshold exceeded
|
|
2 LES 15 minute threshold exceeded
|
|
3 LES 24 hour threshold exceeded
|
|
4 LSES 15 minute threshold exceeded
|
|
5 LSES 24 hour threshold exceeded
|
|
6 PCV 15 minute threshold exceeded
|
|
7 PCV 24 hour threshold exceeded
|
|
8 PES 15 minute threshold exceeded
|
|
9 PES 24 hour threshold exceeded
|
|
10 PSES 15 minute threshold exceeded
|
|
11 PSES 24 hour threshold exceeded
|
|
12 SEFS 15 minute threshold exceeded
|
|
13 SEFS 24 hour threshold exceeded
|
|
14 AISS 15 minute threshold exceeded
|
|
15 AISS 24 hour threshold exceeded
|
|
16 UAS 15 minute threshold exceeded
|
|
17 UAS 24 hour threshold exceeded
|
|
18 BIP8CV/G.832 15 minute threshold exceeded
|
|
19 BIP8CV/G.832 24 hour threshold exceeded
|
|
20 BIP8ES/G.832 15 minute threshold exceeded
|
|
21 BIP8ES/G.832 24 hour threshold exceeded
|
|
22 BIP8SES/G.832 15 minute threshold exceeded
|
|
23 BIP8SES/G.832 24 hour threshold exceeded
|
|
24 CCV 15 minute threshold exceeded
|
|
25 CCV 24 hour threshold exceeded
|
|
26 CES 15 minute threshold exceeded
|
|
27 CES 24 hour threshold exceeded
|
|
28 CSES 15 minute threshold exceeded
|
|
29 CSES 24 hour threshold exceeded
|
|
|
|
Bits 18 to 23 do not have any significance if the framing is
|
|
G.751(which is used in FRSM_VHS)
|
|
only bits 0,1,2,3,4,5,16 and 17 are applicable to CESM-T3/E3.
|
|
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { dsx3AlarmEntry 2 }
|
|
|
|
dsx3LCVCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Code Violations(LCV)
|
|
encountered by the interface in current
|
|
15 minute period."
|
|
::= { dsx3AlarmEntry 3 }
|
|
|
|
dsx3LCV15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Code Violations(LCV)
|
|
encountered by the interface in current
|
|
last 15 minute period."
|
|
::= { dsx3AlarmEntry 4 }
|
|
|
|
dsx3LCV24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Code Violations(LCV)
|
|
encountered by the interface in current
|
|
last 24 hour period."
|
|
::= { dsx3AlarmEntry 5 }
|
|
|
|
dsx3LESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Errored Seconds(LES)
|
|
encountered by the interface in current
|
|
15 minute period."
|
|
::= { dsx3AlarmEntry 6 }
|
|
|
|
dsx3LES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Errored Seconds(LES)
|
|
encountered by the interface in last
|
|
15 minute period."
|
|
::= { dsx3AlarmEntry 7}
|
|
|
|
dsx3LES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Errored Seconds(LES)
|
|
encountered by the interface in last
|
|
24 hour period."
|
|
::= { dsx3AlarmEntry 8 }
|
|
|
|
dsx3LSESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Severely Errored Seconds(LSES)
|
|
encountered by the interface in current
|
|
15 minute period."
|
|
::= { dsx3AlarmEntry 9 }
|
|
|
|
dsx3LSES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Severely Errored Seconds(LSES)
|
|
encountered by the interface in last
|
|
15 minute period."
|
|
::= { dsx3AlarmEntry 10 }
|
|
|
|
dsx3LSES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Line Severely Errored Seconds(LSES)
|
|
encountered by the interface in last
|
|
24 hour period."
|
|
::= { dsx3AlarmEntry 11 }
|
|
|
|
dsx3PCVCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Coding Violations(PCV)
|
|
encountered by the interface in current
|
|
15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 12 }
|
|
|
|
dsx3PCV15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Coding Violations(PCV)
|
|
encountered by the interface in last
|
|
15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 13 }
|
|
|
|
dsx3PCV24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Coding Violations(PCV)
|
|
encountered by the interface in last
|
|
24 Hour period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 14 }
|
|
|
|
dsx3PESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Errored Seconds(PES)
|
|
encountered by the interface in current
|
|
15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 15 }
|
|
|
|
dsx3PES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Errored Seconds(PES)
|
|
encountered by the interface in last
|
|
15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 16 }
|
|
|
|
dsx3PES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Errored Seconds(PES)
|
|
encountered by the interface in last
|
|
24 Hour period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 17 }
|
|
|
|
dsx3PSESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Severely Errored
|
|
Seconds(PSES) encountered by the interface
|
|
in current 15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 18 }
|
|
|
|
dsx3PSES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Severely Errored
|
|
Seconds(PSES) encountered by the interface
|
|
in last 15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 19 }
|
|
|
|
dsx3PSES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit Severely Errored
|
|
Seconds(PSES) encountered by the interface
|
|
in last 24 Hour period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 20 }
|
|
|
|
dsx3SEFSCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Severely Errored Framing
|
|
Seconds(PSES) encountered by the interface
|
|
in current 15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 21 }
|
|
|
|
dsx3SEFS15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Severely Errored Framing
|
|
Seconds(PSES) encountered by the interface
|
|
in last 15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 22 }
|
|
|
|
dsx3SEFS24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Severely Errored Framing
|
|
Seconds(PSES) encountered by the interface
|
|
in last 24 Hour period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 23 }
|
|
|
|
dsx3AISSCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of AIS Severely Errored Seconds
|
|
encountered by the interface in current 15 minute
|
|
period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 24 }
|
|
|
|
dsx3AISS15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of AIS Severely Errored Seconds
|
|
encountered by the interface in last 15 minute
|
|
period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 25 }
|
|
|
|
dsx3AISS24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of AIS Severely Errored Seconds
|
|
encountered by the interface in last 24 Hour
|
|
period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 26 }
|
|
|
|
dsx3UASCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Unavailable Seconds(UAS)
|
|
encountered by the interface in current
|
|
15 minute period."
|
|
::= { dsx3AlarmEntry 27 }
|
|
|
|
dsx3UAS15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Unavailable Seconds(UAS)
|
|
encountered by the interface in last
|
|
15 minute period."
|
|
::= { dsx3AlarmEntry 28 }
|
|
|
|
dsx3UAS24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Unavailable Seconds(UAS)
|
|
encountered by the interface in last
|
|
24 Hour period."
|
|
::= { dsx3AlarmEntry 29 }
|
|
|
|
dsx3PercentLcvEFS OBJECT-TYPE
|
|
SYNTAX Integer32(0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the percentage of
|
|
seconds without any LCV Errors in the
|
|
total elapsed seconds."
|
|
::= { dsx3AlarmEntry 30 }
|
|
|
|
dsx3E3BIP8CVCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Coding Violations
|
|
(CV) encountered by the interface in current
|
|
15 minute period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 31 }
|
|
|
|
dsx3E3BIP8CV15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Coding Violations
|
|
(CV) encountered by the interface in last
|
|
15 minute period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 32 }
|
|
|
|
dsx3E3BIP8CV24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Coding Violations
|
|
(CV) encountered by the interface in last
|
|
24 Hour period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 33 }
|
|
|
|
dsx3E3BIP8ESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Errored Seconds(ES)
|
|
encountered by the interface in current
|
|
15 minute period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 34 }
|
|
|
|
dsx3E3BIP8ES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Errored Seconds(ES)
|
|
encountered by the interface in last
|
|
15 minute period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 35 }
|
|
|
|
dsx3E3BIP8ES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Errored Seconds(ES)
|
|
encountered by the interface in last
|
|
24 Hour period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 36 }
|
|
|
|
dsx3E3BIP8SESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Severely Errored Seconds(SES)
|
|
encountered by the interface in current 15 minute period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 37 }
|
|
|
|
dsx3E3BIP8SES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Severely Errored Seconds(SES)
|
|
encountered by the interface in last 15 minute period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 38 }
|
|
|
|
dsx3E3BIP8SES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of G.832 BIP-8 Severely Errored Seconds(SES)
|
|
encountered by the interface in last 24 Hour period.
|
|
|
|
This object is not supported in FRSM-VHS and
|
|
CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 39 }
|
|
|
|
dsx3LineAlarmClrButton OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
clear(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to dsx3LineAlarmClear will
|
|
cause all the alarms statuses and counters to reset."
|
|
::= {dsx3AlarmEntry 40 }
|
|
|
|
dsx3CCVCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Coding Violations(CCV)
|
|
encountered by the interface in current
|
|
15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 41 }
|
|
|
|
dsx3CCV15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Coding Violations(CCV)
|
|
encountered by the interface in last
|
|
15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 42 }
|
|
|
|
dsx3CCV24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Coding Violations(CCV)
|
|
encountered by the interface in last
|
|
24 Hour period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 43 }
|
|
|
|
dsx3CESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Errored Seconds(CES)
|
|
encountered by the interface in current
|
|
15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 44 }
|
|
|
|
dsx3CES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Errored Seconds(CES)
|
|
encountered by the interface in last
|
|
15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 45 }
|
|
|
|
dsx3CES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Errored Seconds(CES)
|
|
encountered by the interface in last
|
|
24 Hour period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 46 }
|
|
|
|
dsx3CSESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Severely Errored Seconds(CSES)
|
|
encountered by the interface in current 15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 47 }
|
|
|
|
dsx3CSES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Severely Errored Seconds(CSES)
|
|
encountered by the interface in last 15 minute period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 48 }
|
|
|
|
dsx3CSES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of C-bit Severely Errored Seconds(CSES)
|
|
encountered by the interface in last 24 Hour period.
|
|
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3AlarmEntry 49 }
|
|
|
|
|
|
-- --------------------------------------------------------------
|
|
--
|
|
-- Group "dsx3Counters"
|
|
--
|
|
-- --------------------------------------------------------------
|
|
|
|
dsx3CounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx3CounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is for ds3/e3 statistics. This table
|
|
maintains the number of times the line encountered
|
|
LOS, LOF, AIS, RAI, CCV and Framing Errors(FE)
|
|
from the time it is up. Error statistics are
|
|
cleared when the line is brought up from the failure
|
|
state."
|
|
::= { dsx3Counter 1 }
|
|
|
|
dsx3CounterEntry OBJECT-TYPE
|
|
SYNTAX Dsx3CounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table. Statistics are gathered
|
|
for each ds3/e3 interface. An entry is created
|
|
automatically for each ds3/e3 interface that
|
|
is activated."
|
|
INDEX { dsx3LineNum }
|
|
::= { dsx3CounterTable 1 }
|
|
|
|
Dsx3CounterEntry ::=
|
|
SEQUENCE {
|
|
dsx3RcvLOSCount Counter32,
|
|
dsx3RcvOOFCount Counter32,
|
|
dsx3RAICount Counter32,
|
|
dsx3CCVCount Counter32,
|
|
dsx3FECount Counter32,
|
|
dsx3AtmHECCount Counter32,
|
|
dsx3AtmHECSecCount Counter32,
|
|
dsx3AtmSEHECSecCount Counter32,
|
|
dsx3CounterClrButton INTEGER,
|
|
dsx3RcvPERRCounter Counter32,
|
|
dsx3RcvFEBECounter Counter32,
|
|
dsx3RcvEXZCounter Counter32,
|
|
dsx3LCVCount Counter32
|
|
}
|
|
|
|
dsx3RcvLOSCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the Loss of Signal was detected
|
|
with or without integrating to LOS alarm."
|
|
::= { dsx3CounterEntry 1 }
|
|
|
|
dsx3RcvOOFCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the Out of Frame was detected
|
|
with or without integrating to OOF alarm.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 2 }
|
|
|
|
dsx3RAICount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times Yellow Alarms was detected with
|
|
or without integrating to RAI alarm.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 3 }
|
|
|
|
dsx3CCVCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of C Bit
|
|
Coding Violations encountered by a DS3/E3 interface.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 4 }
|
|
|
|
dsx3FECount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Framing Pattern Errors encountered by
|
|
a DS3/E3 interface.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 5 }
|
|
|
|
dsx3AtmHECCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Header Check Sequence(HCS) Errors.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 6 }
|
|
|
|
dsx3AtmHECSecCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of HEC errored seconds.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 7 }
|
|
|
|
dsx3AtmSEHECSecCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Severely HEC error seconds.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 8 }
|
|
|
|
dsx3CounterClrButton OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
clear (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to clear all the counters."
|
|
::= { dsx3CounterEntry 9 }
|
|
|
|
dsx3RcvPERRCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of P-bit parity error.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 10 }
|
|
|
|
|
|
dsx3RcvFEBECounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Far-end block error.
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 11 }
|
|
|
|
dsx3RcvEXZCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of excessive zeros
|
|
This object is not supported in CESM-T3/E3"
|
|
::= { dsx3CounterEntry 12 }
|
|
|
|
dsx3LCVCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line
|
|
Coding Violations encountered by a DS3/E3 interface."
|
|
::= { dsx3CounterEntry 13 }
|
|
|
|
|
|
-- --------------------------------------------------------------
|
|
--
|
|
-- dsx3PlcpConfig group
|
|
-- This group contains dsx3Plcp configuration table
|
|
--
|
|
-- --------------------------------------------------------------
|
|
dsx3PlcpConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx3PlcpConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains ATM interface DS3 PLCP
|
|
configuration parameters."
|
|
::= { dsx3PlcpConfig 1 }
|
|
|
|
dsx3PlcpConfigEntry OBJECT-TYPE
|
|
SYNTAX Dsx3PlcpConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DSX3 PLCP Configuration table."
|
|
INDEX { dsx3PlcpNum }
|
|
::= { dsx3PlcpConfigTable 1 }
|
|
|
|
Dsx3PlcpConfigEntry ::=
|
|
SEQUENCE {
|
|
dsx3PlcpNum Integer32,
|
|
dsx3PlcpCellFraming INTEGER,
|
|
dsx3PlcpPayloadScramble INTEGER,
|
|
dsx3PlcpLoopCommand INTEGER
|
|
}
|
|
|
|
dsx3PlcpNum OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the dsx3 PLCP interface.
|
|
The value of this object must be same as the value
|
|
specified in 'dsx3LineNum' object from cwDsx3ConfigTable."
|
|
::= { dsx3PlcpConfigEntry 1 }
|
|
|
|
dsx3PlcpCellFraming OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
framingByPlcp (1),
|
|
framingbyAtmHec (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for this object sets the cell delineation
|
|
method used by the interface. The cell delineation
|
|
defines how a receiving device recognizes the start
|
|
and end of an ATM cell.
|
|
|
|
framingByPlcp (1): The ATM Cells are in predetermined
|
|
location within each PLCP row, so
|
|
no additional method is needed to
|
|
delineate ATM cells.
|
|
framingByAtmHec (2): The Header Error Control field of the
|
|
ATM cell header is used to delineate
|
|
ATM cells.
|
|
"
|
|
::= { dsx3PlcpConfigEntry 2 }
|
|
|
|
dsx3PlcpPayloadScramble OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enableScrambling (1),
|
|
disableScrambling (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for this object is used for enabling/disabling
|
|
PLCP cell scrambling."
|
|
::= { dsx3PlcpConfigEntry 3 }
|
|
|
|
dsx3PlcpLoopCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoop (1),
|
|
remoteLineLoop (2),
|
|
localLineLoop (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"specifies the type of loopback on the line.
|
|
|
|
The possible value(s) are :
|
|
noLoop (1): Not in loopback.
|
|
remoteLineLoop (2): Remote Line Loopback.
|
|
localLineLoop (3): Local Line Loopback."
|
|
::= { dsx3PlcpConfigEntry 4 }
|
|
|
|
dsx3PlcpNumOfValidEntries OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the maximum number of
|
|
entries in cwDsx3ConfigTable."
|
|
::= { dsx3PlcpConfig 2 }
|
|
|
|
-- --------------------------------------------------------------
|
|
--
|
|
-- dsx3PlcpAlarmConfig group
|
|
--
|
|
-- --------------------------------------------------------------
|
|
dsx3PlcpAlarmConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx3PlcpAlarmConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the ATM interface PLCP alarm
|
|
parameters."
|
|
::= { dsx3PlcpAlarmConfig 1 }
|
|
|
|
dsx3PlcpAlarmConfigEntry OBJECT-TYPE
|
|
SYNTAX Dsx3PlcpAlarmConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DSX3 PLCP Alarm Configuration table.
|
|
|
|
Thresholds may be configured for:
|
|
|
|
Errored Seconds (ES)
|
|
Coding Violations (CV)
|
|
Severely Errored Seconds (SES)
|
|
Unavailable Seconds (UAS),
|
|
Once these thresholds are exceeded, minor or major alarms
|
|
are raised. Please refer to RFC2496 for descriptions of these
|
|
errors."
|
|
INDEX { dsx3PlcpNum }
|
|
::= { dsx3PlcpAlarmConfigTable 1 }
|
|
|
|
Dsx3PlcpAlarmConfigEntry ::=
|
|
SEQUENCE {
|
|
dsx3PlcpRedSeverity INTEGER,
|
|
dsx3PlcpRAISeverity INTEGER,
|
|
dsx3PlcpLssSeverity INTEGER,
|
|
dsx3PlcpLssEnable INTEGER,
|
|
dsx3PlcpLssCodeConnected Integer32,
|
|
dsx3PlcpLssCodeRxLinkDn Integer32,
|
|
dsx3PlcpLssCodeRxLinkUp Integer32,
|
|
dsx3PlcpStatisticalAlarmSeverity INTEGER,
|
|
dsx3PlcpBip8CV15MinThreshold Integer32,
|
|
dsx3PlcpBip8CV24HrThreshold Integer32,
|
|
dsx3PlcpBip8ES15MinThreshold Integer32,
|
|
dsx3PlcpBip8ES24HrThreshold Integer32,
|
|
dsx3PlcpBip8SES15MinThreshold Integer32,
|
|
dsx3PlcpBip8SES24HrThreshold Integer32,
|
|
dsx3PlcpSEFS15MinThreshold Integer32,
|
|
dsx3PlcpSEFS24HrThreshold Integer32,
|
|
dsx3PlcpUAS15MinThreshold Integer32,
|
|
dsx3PlcpUAS24HrThreshold Integer32
|
|
}
|
|
|
|
dsx3PlcpRedSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minor(1),
|
|
major(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to setup the severity of PLCP RED
|
|
alarm. So when PLCP_OOF alarm is detected the card will
|
|
declare the alarm with appropriate severity status.
|
|
A major alarm will cause the audible notification
|
|
and the MAJOR ALARM LED will be turned ON.
|
|
A minor alarm will just turn on the MINOR ALARM LED."
|
|
::= { dsx3PlcpAlarmConfigEntry 1 }
|
|
|
|
dsx3PlcpRAISeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minor(1),
|
|
major(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to setup the severity of
|
|
PLCP RAI alarm. So when PLCP RAI alarm is detected
|
|
the card will send the alarm with appropriate severity
|
|
status.
|
|
A major alarm will cause the audible notification
|
|
and the MAJOR ALARM LED will be turned ON.
|
|
A minor alarm will just turn on the MINOR ALARM LED."
|
|
::= { dsx3PlcpAlarmConfigEntry 2 }
|
|
|
|
dsx3PlcpLssSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minor(1),
|
|
major(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to setup the severity of
|
|
PLCP RAI alarm. So when PLCP LSS alarm is detected
|
|
the card will send the alarm with appropriate severity
|
|
status.
|
|
A major alarm will cause the audible notification
|
|
and the MAJOR ALARM LED will be turned ON.
|
|
A minor alarm will just turn on the MINOR ALARM LED."
|
|
::= { dsx3PlcpAlarmConfigEntry 3 }
|
|
|
|
dsx3PlcpLssEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lssEnable (1),
|
|
lssDisable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects specifies whether the LSS feature is
|
|
enabled/disabled."
|
|
::= { dsx3PlcpAlarmConfigEntry 4 }
|
|
|
|
dsx3PlcpLssCodeConnected OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object derfines the value of the LSS code
|
|
that is to be interpreted as Link Connected."
|
|
::= { dsx3PlcpAlarmConfigEntry 5 }
|
|
|
|
dsx3PlcpLssCodeRxLinkDn OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the value of the LSS code
|
|
that is to be identified as Receive Link Down."
|
|
::= { dsx3PlcpAlarmConfigEntry 6 }
|
|
|
|
dsx3PlcpLssCodeRxLinkUp OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the value of the LSS code that
|
|
is to be interpreted as Receive Link Up."
|
|
::= { dsx3PlcpAlarmConfigEntry 7 }
|
|
|
|
dsx3PlcpStatisticalAlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
minor(1),
|
|
major(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable sets up the severity of PLCP Statistical
|
|
alarm. So when PLCP Statistical alarm is detected, the
|
|
card will send the alarm with appropriate severity.
|
|
A major alarm will cause the audible notification
|
|
and the MAJOR ALARM LED will be turned ON.
|
|
A minor alarm will just turn on the MINOR ALARM LED.
|
|
"
|
|
::= { dsx3PlcpAlarmConfigEntry 8 }
|
|
|
|
dsx3PlcpBip8CV15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared."
|
|
::= { dsx3PlcpAlarmConfigEntry 9 }
|
|
|
|
dsx3PlcpBip8CV24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval"
|
|
::= { dsx3PlcpAlarmConfigEntry 10 }
|
|
|
|
dsx3PlcpBip8ES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared."
|
|
::= { dsx3PlcpAlarmConfigEntry 11 }
|
|
|
|
dsx3PlcpBip8ES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval"
|
|
::= { dsx3PlcpAlarmConfigEntry 12 }
|
|
|
|
dsx3PlcpBip8SES15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared."
|
|
::= { dsx3PlcpAlarmConfigEntry 13 }
|
|
|
|
dsx3PlcpBip8SES24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval"
|
|
::= { dsx3PlcpAlarmConfigEntry 14 }
|
|
|
|
dsx3PlcpSEFS15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared."
|
|
::= { dsx3PlcpAlarmConfigEntry 15 }
|
|
|
|
dsx3PlcpSEFS24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval"
|
|
::= { dsx3PlcpAlarmConfigEntry 16 }
|
|
|
|
dsx3PlcpUAS15MinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a 15 minute window
|
|
causes a statistical alarm to be declared."
|
|
::= { dsx3PlcpAlarmConfigEntry 17 }
|
|
|
|
dsx3PlcpUAS24HrThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value set in this object determines the
|
|
value which when exceeded in a sliding 24 hour
|
|
window causes a statistical alarm to be declared.
|
|
The threshold is checked every 15 minutes for the
|
|
preceding 24 hour interval"
|
|
::= { dsx3PlcpAlarmConfigEntry 18 }
|
|
|
|
-- --------------------------------------------------------------
|
|
--
|
|
-- dsx3PlcpAlarm group
|
|
-- This group contains dsx3 Alarm table
|
|
--
|
|
-- --------------------------------------------------------------
|
|
dsx3PlcpAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx3PlcpAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains ATM interface DS3 PLCP
|
|
alarm configuration."
|
|
::= { dsx3PlcpAlarm 1 }
|
|
|
|
dsx3PlcpAlarmEntry OBJECT-TYPE
|
|
SYNTAX Dsx3PlcpAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM DS3 PLCP alarm table.
|
|
Bucket statistics (15 minute and 24 Hour interval)
|
|
are gathered for each ds3/e3 interface automatically."
|
|
INDEX { dsx3PlcpNum }
|
|
::= { dsx3PlcpAlarmTable 1 }
|
|
|
|
Dsx3PlcpAlarmEntry ::=
|
|
SEQUENCE {
|
|
dsx3PlcpLineAlarmState Integer32,
|
|
dsx3PlcpLineStatisticalAlarmState Integer32,
|
|
dsx3PlcpBip8CVCurrent Counter32,
|
|
dsx3PlcpBip8CV15MinBucket Counter32,
|
|
dsx3PlcpBip8CV24HrBucket Counter32,
|
|
dsx3PlcpBip8ESCurrent Counter32,
|
|
dsx3PlcpBip8ES15MinBucket Counter32,
|
|
dsx3PlcpBip8ES24HrBucket Counter32,
|
|
dsx3PlcpBip8SESCurrent Counter32,
|
|
dsx3PlcpBip8SES15MinBucket Counter32,
|
|
dsx3PlcpBip8SES24HrBucket Counter32,
|
|
dsx3PlcpSEFSCurrent Counter32,
|
|
dsx3PlcpSEFS15MinBucket Counter32,
|
|
dsx3PlcpSEFS24HrBucket Counter32,
|
|
dsx3PlcpUASCurrent Counter32,
|
|
dsx3PlcpUAS15MinBucket Counter32,
|
|
dsx3PlcpUAS24HrBucket Counter32,
|
|
dsx3PlcpAlarmClrButton INTEGER
|
|
}
|
|
|
|
dsx3PlcpLineAlarmState OBJECT-TYPE
|
|
SYNTAX Integer32 (0..511)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is a bitmap of the DSX3 Line alarms.
|
|
A value of zero indicates no alarms.
|
|
|
|
Itemized below are the individual bits:
|
|
|
|
BitPosition Alarm
|
|
----------- -----
|
|
0 Receiving RAI
|
|
1 Transmitting RAI
|
|
2 Receiving OOF
|
|
3 Receiving LSS Link Up
|
|
4 Transmitting LSS Link Up
|
|
5 Receiving LSS Link Down
|
|
6 Transmitting LSS Link Down
|
|
7 Near End Local Loopback in effect
|
|
8 Near End Remote Loopback in effect
|
|
"
|
|
::= { dsx3PlcpAlarmEntry 1 }
|
|
|
|
dsx3PlcpLineStatisticalAlarmState OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is a bitmap of the DSX3 Line Statictical
|
|
Alarms on the card. A value of zero indicates no alarms.
|
|
|
|
Itemized below are the individual alarm bits:
|
|
|
|
BitPosition Alarm
|
|
----------- -----
|
|
0 Bip8CV 15 minute threshold exceeded
|
|
1 Bip8CV 24 hour threshold exceeded
|
|
2 Bip8ES 15 minute threshold exceeded
|
|
3 Bip8ES 24 hour threshold exceeded
|
|
4 Bip8SES 15 minute threshold exceeded
|
|
5 Bip8SES 24 hour threshold exceeded
|
|
6 Plcp SEFS 15 minute threshold exceeded
|
|
7 Plcp SEFS 24 hour threshold exceeded
|
|
8 Plcp UAS 15 minute threshold exceeded
|
|
9 Plcp UAS 24 hour threshold exceeded
|
|
"
|
|
::= { dsx3PlcpAlarmEntry 2 }
|
|
|
|
dsx3PlcpBip8CVCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
BIP-8 code violations encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 3 }
|
|
|
|
dsx3PlcpBip8CV15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
BIP-8 code violations in the last 15 minute period
|
|
encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 4 }
|
|
|
|
dsx3PlcpBip8CV24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
BIP-8 code violations in the last 24 hour period
|
|
encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 5 }
|
|
|
|
dsx3PlcpBip8ESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
BIP-8 code violations Errored Seconds
|
|
encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 6 }
|
|
|
|
dsx3PlcpBip8ES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
BIP-8 code violations Errored Seconds in the
|
|
last 15 minutes encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 7 }
|
|
|
|
dsx3PlcpBip8ES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
BIP-8 code violations Errored Seconds in the
|
|
last 24 hours encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 8 }
|
|
|
|
dsx3PlcpBip8SESCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
Bip8 code violations Severely Errored Seconds
|
|
encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 9 }
|
|
|
|
dsx3PlcpBip8SES15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
BIP-8 Severely Errored Seconds in the last
|
|
15 minutes encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 10 }
|
|
|
|
dsx3PlcpBip8SES24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
BIP-8 Severely Errored Seconds in the last
|
|
24 hours encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 11 }
|
|
|
|
dsx3PlcpSEFSCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
Severely Errored Framing Seconds
|
|
encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 12 }
|
|
|
|
dsx3PlcpSEFS15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
Severely Errored Framing Seconds in the last
|
|
15 minutes encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 13 }
|
|
|
|
dsx3PlcpSEFS24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
Severely Errored Framing Seconds in the last
|
|
24 hours encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 14 }
|
|
|
|
dsx3PlcpUASCurrent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
Unavailable Seconds encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 15 }
|
|
|
|
dsx3PlcpUAS15MinBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
Unavailable Seconds in the last 15 minutes
|
|
encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 16 }
|
|
|
|
dsx3PlcpUAS24HrBucket OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter counts the number of
|
|
Unavailable Seconds in the last 24 hours
|
|
encountered by the interface."
|
|
::= { dsx3PlcpAlarmEntry 17 }
|
|
|
|
dsx3PlcpAlarmClrButton OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dsx3PlcpAlarmNoAction (1),
|
|
dsx3PlcpAlarmClear (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to clear all the alarms."
|
|
::= { dsx3PlcpAlarmEntry 18 }
|
|
|
|
|
|
-- --------------------------------------------------------------
|
|
--
|
|
-- Group "dsx3PlcpCounters"
|
|
--
|
|
-- --------------------------------------------------------------
|
|
|
|
dsx3PlcpCounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx3PlcpCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for DS3 PLCP counter table."
|
|
::= { dsx3PlcpCounter 1 }
|
|
|
|
dsx3PlcpCounterEntry OBJECT-TYPE
|
|
SYNTAX Dsx3PlcpCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DS3 PLCP counter table."
|
|
INDEX { dsx3PlcpNum }
|
|
::= { dsx3PlcpCounterTable 1 }
|
|
|
|
Dsx3PlcpCounterEntry ::=
|
|
SEQUENCE {
|
|
dsx3PlcpRcvBip8Count Counter32,
|
|
dsx3PlcpRcvOOFCount Counter32,
|
|
dsx3PlcpRcvRAICount Counter32,
|
|
dsx3PlcpFECount Counter32,
|
|
dsx3PlcpFESecCount Counter32,
|
|
dsx3PlcpSEFESecCount Counter32,
|
|
dsx3PlcpFEBECount Counter32,
|
|
dsx3PlcpFEBESecCount Counter32,
|
|
dsx3PlcpSEFEBESecCount Counter32,
|
|
dsx3PlcpHECCount Counter32,
|
|
dsx3PlcpHECSecCount Counter32,
|
|
dsx3PlcpSEHECSecCount Counter32,
|
|
dsx3PlcpCounterClrButton INTEGER
|
|
}
|
|
|
|
dsx3PlcpRcvBip8Count OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of BIP-8 errors encountered by
|
|
the interface."
|
|
::= { dsx3PlcpCounterEntry 1 }
|
|
|
|
dsx3PlcpRcvOOFCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the Out of Frame(OOF) was detected
|
|
with or without integrating to OOF alarm."
|
|
::= { dsx3PlcpCounterEntry 2 }
|
|
|
|
dsx3PlcpRcvRAICount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times Remote Alarm Indication(RAI)
|
|
was detected with or without integrating to RAI alarm."
|
|
::= { dsx3PlcpCounterEntry 3 }
|
|
|
|
dsx3PlcpFECount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Framing Errors detected."
|
|
::= { dsx3PlcpCounterEntry 4 }
|
|
|
|
dsx3PlcpFESecCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Framing Error errored seconds."
|
|
::= { dsx3PlcpCounterEntry 5 }
|
|
|
|
dsx3PlcpSEFESecCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Severely errored Framing error seconds."
|
|
::= { dsx3PlcpCounterEntry 6 }
|
|
|
|
dsx3PlcpFEBECount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Far End Block Errors(FEBE) detected."
|
|
::= { dsx3PlcpCounterEntry 7 }
|
|
|
|
dsx3PlcpFEBESecCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of FEBE errored seconds."
|
|
::= { dsx3PlcpCounterEntry 8 }
|
|
|
|
dsx3PlcpSEFEBESecCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Severely errored FEBE seconds."
|
|
::= { dsx3PlcpCounterEntry 9 }
|
|
|
|
dsx3PlcpHECCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of HCS Errors."
|
|
::= { dsx3PlcpCounterEntry 10 }
|
|
|
|
dsx3PlcpHECSecCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of HEC errored seconds."
|
|
::= { dsx3PlcpCounterEntry 11 }
|
|
|
|
dsx3PlcpSEHECSecCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Severely HEC error seconds."
|
|
::= { dsx3PlcpCounterEntry 12 }
|
|
|
|
dsx3PlcpCounterClrButton OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dsx3PlcpCounterNoAction (1),
|
|
dsx3PlcpCounterClear (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to clear all the counters."
|
|
::= { dsx3PlcpCounterEntry 13 }
|
|
|
|
dsx3PlcpCounterValidEntries OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of entries in
|
|
the dsx3PlcpCounterTable."
|
|
::= { dsx3PlcpCounter 2 }
|
|
|
|
-- conformance information
|
|
|
|
cmDsx3MIBConformance OBJECT IDENTIFIER ::= { ciscoMgx82xxDsx3MIB 2 }
|
|
|
|
cmDsx3MIBGroups OBJECT IDENTIFIER ::=
|
|
{ cmDsx3MIBConformance 1 }
|
|
|
|
cmDsx3MIBCompliances OBJECT IDENTIFIER ::=
|
|
{ cmDsx3MIBConformance 2 }
|
|
|
|
-- compliance statements
|
|
|
|
cmDsx3Compliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for objects related
|
|
to DS3 MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmDsx3GeneralGroup,
|
|
cmDsx3ConfGroup,
|
|
cmDsx3BertConfigGroup,
|
|
cmDsx3StatsGroup,
|
|
cmDsx3E3AlarmConfGenGroup,
|
|
cmDsx3AlarmStatsGenGroup,
|
|
cmDsx3PlcpConfGroup,
|
|
cmDsx3PlcpStatsGroup,
|
|
cmDsx3PlcpAlarmConfGroup,
|
|
cmDsx3PlcpAlarmGroup
|
|
}
|
|
|
|
GROUP cmDsx3E3ConfGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for those cards
|
|
which support E3 interfaces."
|
|
|
|
GROUP cmDsx3AlarmConfGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for those cards
|
|
which support DS3 interfaces."
|
|
|
|
GROUP cmDsx3E3AlarmConfGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for those cards
|
|
which support E3 interfaces."
|
|
|
|
GROUP cmDsx3AlarmStatsGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for those cards
|
|
which support DS3 interfaces."
|
|
|
|
GROUP cmDsx3E3AlarmStatsGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for those cards
|
|
which support E3 interfaces."
|
|
::= { cmDsx3MIBCompliances 1 }
|
|
|
|
cmDsx3GeneralGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3LineNumOfValidEntries,
|
|
dsx3PlcpNumOfValidEntries,
|
|
dsx3PlcpCounterValidEntries
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are used for
|
|
providing number of entries in dsx3 and PLCP
|
|
tables."
|
|
::= { cmDsx3MIBGroups 1 }
|
|
|
|
cmDsx3ConfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3LineNum,
|
|
cwDsx3LineType,
|
|
cwDsx3LineCoding,
|
|
cwDsx3LineLength,
|
|
dsx3LineOOFCriteria,
|
|
dsx3LineAIScBitsCheck,
|
|
dsx3LineLoopbackCommand,
|
|
dsx3LineXmtFEACCode,
|
|
dsx3LineEnable,
|
|
dsx3FarEndLoopbkLineNum,
|
|
dsx3LineXmtClockSrc,
|
|
dsx3FarEndLoopbkLineStatus,
|
|
dsx3LineEqualizer,
|
|
dsx3NearEndLoopbkLineStatus,
|
|
dsx3SubRateEnable,
|
|
dsx3DsuSelect,
|
|
dsx3LineRate,
|
|
dsx3LineScrambleEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are used for
|
|
configuring DS3/E3 interfaces."
|
|
::= { cmDsx3MIBGroups 2 }
|
|
|
|
cmDsx3E3ConfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3LineRcvFEACValidation,
|
|
dsx3TrailTraceOption,
|
|
dsx3TxTrailTrace,
|
|
dsx3RxTrailTrace,
|
|
dsx3TxTimingMarker,
|
|
dsx3RxTimingMarker,
|
|
dsx3TxPayloadType,
|
|
dsx3RxPayloadType,
|
|
dsx3TxTumf,
|
|
dsx3RxTumf
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are applicable
|
|
for E3 interfaces only."
|
|
::= { cmDsx3MIBGroups 3 }
|
|
|
|
cmDsx3BertConfigGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3LineBERTEnable,
|
|
dsx3LineBERTPattern,
|
|
dsx3LineBERTResult,
|
|
dsx3BERTResultClrButton
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are used for
|
|
BERT on DS3/E3 interfaces."
|
|
::= { cmDsx3MIBGroups 4 }
|
|
|
|
cmDsx3StatsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3RcvLOSCount,
|
|
dsx3RcvOOFCount,
|
|
dsx3RAICount,
|
|
dsx3CCVCount,
|
|
dsx3FECount,
|
|
dsx3AtmHECCount,
|
|
dsx3AtmHECSecCount,
|
|
dsx3AtmSEHECSecCount,
|
|
dsx3CounterClrButton,
|
|
dsx3RcvPERRCounter,
|
|
dsx3RcvFEBECounter,
|
|
dsx3RcvEXZCounter,
|
|
dsx3LCVCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects related to
|
|
DS3/E3 statistics."
|
|
::= { cmDsx3MIBGroups 5 }
|
|
|
|
cmDsx3E3AlarmConfGenGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3RedSeverity,
|
|
dsx3RAISeverity,
|
|
dsx3NEAlarmUpCount,
|
|
dsx3NEAlarmDownCount,
|
|
dsx3NEAlarmThreshold,
|
|
dsx3FEAlarmUpCount,
|
|
dsx3FEAlarmDownCount,
|
|
dsx3FEAlarmThreshold,
|
|
dsx3StatisticalAlarmSeverity,
|
|
dsx3LCV15MinThreshold,
|
|
dsx3LCV24HrThreshold,
|
|
dsx3LES15MinThreshold,
|
|
dsx3LES24HrThreshold,
|
|
dsx3LSES15MinThreshold,
|
|
dsx3LSES24HrThreshold,
|
|
dsx3SEFS15MinThreshold,
|
|
dsx3SEFS24HrThreshold,
|
|
dsx3UAS15MinThreshold,
|
|
dsx3UAS24HrThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used for
|
|
alarm configuration of DS3 and E3 interfaces."
|
|
::= { cmDsx3MIBGroups 6 }
|
|
|
|
cmDsx3AlarmConfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3PCV15MinThreshold,
|
|
dsx3PCV24HrThreshold,
|
|
dsx3PES15MinThreshold,
|
|
dsx3PES24HrThreshold,
|
|
dsx3PSES15MinThreshold,
|
|
dsx3PSES24HrThreshold,
|
|
dsx3AISS15MinThreshold,
|
|
dsx3AISS24HrThreshold,
|
|
dsx3CCV15MinThreshold,
|
|
dsx3CCV24HrThreshold,
|
|
dsx3CES15MinThreshold,
|
|
dsx3CES24HrThreshold,
|
|
dsx3CSES15MinThreshold,
|
|
dsx3CSES24HrThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used for
|
|
alarm configuration of DS3 interfaces."
|
|
::= { cmDsx3MIBGroups 7 }
|
|
|
|
cmDsx3E3AlarmConfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3E3BIP8CV15MinThreshold,
|
|
dsx3E3BIP8CV24HrThreshold,
|
|
dsx3E3BIP8ES15MinThreshold,
|
|
dsx3E3BIP8ES24HrThreshold,
|
|
dsx3E3BIP8SES15MinThreshold,
|
|
dsx3E3BIP8SES24HrThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used for
|
|
alarm configuration of E3 interfaces."
|
|
::= { cmDsx3MIBGroups 8 }
|
|
|
|
cmDsx3AlarmStatsGenGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3LineAlarmState,
|
|
dsx3LineStatisticalAlarmState,
|
|
dsx3LCVCurrent,
|
|
dsx3LCV15MinBucket,
|
|
dsx3LCV24HrBucket,
|
|
dsx3LESCurrent,
|
|
dsx3LES15MinBucket,
|
|
dsx3LES24HrBucket,
|
|
dsx3LSESCurrent,
|
|
dsx3LSES15MinBucket,
|
|
dsx3LSES24HrBucket,
|
|
dsx3SEFSCurrent,
|
|
dsx3SEFS15MinBucket,
|
|
dsx3SEFS24HrBucket,
|
|
dsx3UASCurrent,
|
|
dsx3UAS15MinBucket,
|
|
dsx3UAS24HrBucket,
|
|
dsx3PercentLcvEFS,
|
|
dsx3LineAlarmClrButton
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects related to
|
|
performance statistics and error events
|
|
for ds3 end e3 interfaces."
|
|
::= { cmDsx3MIBGroups 9 }
|
|
|
|
cmDsx3AlarmStatsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3PCVCurrent,
|
|
dsx3PCV15MinBucket,
|
|
dsx3PCV24HrBucket,
|
|
dsx3PESCurrent,
|
|
dsx3PES15MinBucket,
|
|
dsx3PES24HrBucket,
|
|
dsx3PSESCurrent,
|
|
dsx3PSES15MinBucket,
|
|
dsx3PSES24HrBucket,
|
|
dsx3AISSCurrent,
|
|
dsx3AISS15MinBucket,
|
|
dsx3AISS24HrBucket,
|
|
dsx3CCVCurrent,
|
|
dsx3CCV15MinBucket,
|
|
dsx3CCV24HrBucket,
|
|
dsx3CESCurrent,
|
|
dsx3CES15MinBucket,
|
|
dsx3CES24HrBucket,
|
|
dsx3CSESCurrent,
|
|
dsx3CSES15MinBucket,
|
|
dsx3CSES24HrBucket
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects related to
|
|
performance statistics and error events
|
|
for ds3 interfaces."
|
|
::= { cmDsx3MIBGroups 10 }
|
|
|
|
cmDsx3E3AlarmStatsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3E3BIP8CVCurrent,
|
|
dsx3E3BIP8CV15MinBucket,
|
|
dsx3E3BIP8CV24HrBucket,
|
|
dsx3E3BIP8ESCurrent,
|
|
dsx3E3BIP8ES15MinBucket,
|
|
dsx3E3BIP8ES24HrBucket,
|
|
dsx3E3BIP8SESCurrent,
|
|
dsx3E3BIP8SES15MinBucket,
|
|
dsx3E3BIP8SES24HrBucket
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects related to
|
|
performance statistics and error events
|
|
for e3 interfaces."
|
|
::= { cmDsx3MIBGroups 11 }
|
|
|
|
cmDsx3PlcpConfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3PlcpNum,
|
|
dsx3PlcpCellFraming,
|
|
dsx3PlcpPayloadScramble,
|
|
dsx3PlcpLoopCommand
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects related to
|
|
PLCP Configuration on DS3 interfaces."
|
|
::= { cmDsx3MIBGroups 12 }
|
|
|
|
cmDsx3PlcpStatsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3PlcpRcvBip8Count,
|
|
dsx3PlcpRcvOOFCount,
|
|
dsx3PlcpRcvRAICount,
|
|
dsx3PlcpFECount,
|
|
dsx3PlcpFESecCount,
|
|
dsx3PlcpSEFESecCount,
|
|
dsx3PlcpFEBECount,
|
|
dsx3PlcpFEBESecCount,
|
|
dsx3PlcpSEFEBESecCount,
|
|
dsx3PlcpHECCount,
|
|
dsx3PlcpHECSecCount,
|
|
dsx3PlcpSEHECSecCount,
|
|
dsx3PlcpCounterClrButton
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects related to
|
|
PLCP statistics on DS3 interfaces."
|
|
::= { cmDsx3MIBGroups 13 }
|
|
|
|
cmDsx3PlcpAlarmConfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3PlcpRedSeverity,
|
|
dsx3PlcpRAISeverity,
|
|
dsx3PlcpLssSeverity,
|
|
dsx3PlcpLssEnable,
|
|
dsx3PlcpLssCodeConnected,
|
|
dsx3PlcpLssCodeRxLinkDn,
|
|
dsx3PlcpLssCodeRxLinkUp,
|
|
dsx3PlcpStatisticalAlarmSeverity,
|
|
dsx3PlcpBip8CV15MinThreshold,
|
|
dsx3PlcpBip8CV24HrThreshold,
|
|
dsx3PlcpBip8ES15MinThreshold,
|
|
dsx3PlcpBip8ES24HrThreshold,
|
|
dsx3PlcpBip8SES15MinThreshold,
|
|
dsx3PlcpBip8SES24HrThreshold,
|
|
dsx3PlcpSEFS15MinThreshold,
|
|
dsx3PlcpSEFS24HrThreshold,
|
|
dsx3PlcpUAS15MinThreshold,
|
|
dsx3PlcpUAS24HrThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used for
|
|
PLCP Alarm configuration on DS3 interfaces."
|
|
::= { cmDsx3MIBGroups 14 }
|
|
|
|
cmDsx3PlcpAlarmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dsx3PlcpLineAlarmState,
|
|
dsx3PlcpLineStatisticalAlarmState,
|
|
dsx3PlcpBip8CVCurrent,
|
|
dsx3PlcpBip8CV15MinBucket,
|
|
dsx3PlcpBip8CV24HrBucket,
|
|
dsx3PlcpBip8ESCurrent,
|
|
dsx3PlcpBip8ES15MinBucket,
|
|
dsx3PlcpBip8ES24HrBucket,
|
|
dsx3PlcpBip8SESCurrent,
|
|
dsx3PlcpBip8SES15MinBucket,
|
|
dsx3PlcpBip8SES24HrBucket,
|
|
dsx3PlcpSEFSCurrent,
|
|
dsx3PlcpSEFS15MinBucket,
|
|
dsx3PlcpSEFS24HrBucket,
|
|
dsx3PlcpUASCurrent,
|
|
dsx3PlcpUAS15MinBucket,
|
|
dsx3PlcpUAS24HrBucket,
|
|
dsx3PlcpAlarmClrButton
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used for
|
|
PLCP Alarm configuration on DS3 interfaces."
|
|
::= { cmDsx3MIBGroups 15 }
|
|
|
|
END
|