-- File : mmblade.mib
|
|
-- Description : IBM Management Module MIB for SNMP
|
|
-- By : Joe Bolan, IBM
|
|
-- Version : 1.1
|
|
-- Date : March 4, 2003
|
|
--
|
|
--
|
|
-- Copyright (c) 2002-2004 IBM All Rights Reserved.
|
|
-- ********************************************************************************
|
|
--
|
|
-- Contains MIB description for:
|
|
-- This MIB is to be used to provide configuration support and monitoring for the
|
|
-- Bladecenter MM
|
|
--
|
|
-- Note:
|
|
--
|
|
-- The following OIDs DO NOT include the SP command number. (Note,
|
|
-- the end portion of most OIDs will contain the SP dot command number.)
|
|
-- (1) currentSysPwrStatus
|
|
-- (2) powerOnHours
|
|
-- (3) restartCount
|
|
-- (4) systemState
|
|
-- (5) generateTestAlert
|
|
-- (6) VPD
|
|
-- (7) Thresholds
|
|
-- (9) Timezone (GMT and DST)
|
|
|
|
-- ********************************************************************************
|
|
-- ********************************************************************************
|
|
-- Revisions:
|
|
-- 03/25/2002 LJI Create new for blade servers based on old ibmrsaag.mib
|
|
-- 03/04/2003 Fix compile errors found on SNMP Director Browser
|
|
-- 12/04/2003 BN Add user profiles to support SNMPv3
|
|
-- 01/19/2004 BN Add critVolt
|
|
-- 01/23/2004 BN Add LEDs for switch modules
|
|
-- 02/02/2004 BN Add SNMPv3 enable/disable
|
|
-- 02/17/2004 BN Add MAC addresses support for blades and daughter cards
|
|
-- 03/05/2004 BN Add firmware update for switch, MM, and blades
|
|
-- 03/11/2004 BN Change texts and remove references to MM under processorblade
|
|
-- section
|
|
-- 03/22/2004 BN Change write-only to read-write on some MIBs
|
|
-- 03/25/2004 PTN Add 4.9.3.4.2 and 4.9.3.4.3
|
|
-- 04/01/2004 BN Add text about duplicate ID to remoteAccessIdEntryUserId
|
|
-- 04/09/2004 BN Add DNS option for LDAP
|
|
-- 04/25/2004 PTN Add 4.9.3.4.5
|
|
-- 04/03/2004 BN Add main application 2 vpd for switch module
|
|
-- 05/13/2004 BN Add notes to Enterprise and Telco specific MIBs
|
|
-- 05/13/2004 BN Add power management / fuel gauge
|
|
-- 05/24/2004 BN Remove underscore (_) in MIB name
|
|
-- 06/17/2004 BN Top Level OID for Testing only
|
|
-- 06/18/2004 BN Infiniband Switch support
|
|
-- 07/06/2004 BN Correct range for OCTET STRING for IBM Director
|
|
-- 07/12/2004 BN Add duty cycles
|
|
-- 08/02/2004 MR Add voltages and temperatures for IPMI blades
|
|
-- 08/18/2004 TDM Add additional powerRestart options for JS20 blade
|
|
-- 09/01/2004 BN Add displayBladeSELEntry
|
|
-- 09/15/2004 MR Add switch module health state
|
|
-- 09/17/2004 BN Add numeric value before text in response message for fuelGaugeStatus
|
|
-- 09/27/2004 MR Add iscsi options to boot path
|
|
-- 10/04/2004 BN Remove displayBladeSELEntry
|
|
-- 10/13/2004 MD Add OEM folder for telcoManagement
|
|
-- 11/17/2004 MR Add power module health state table and blower state
|
|
-- 03/31/2005 BN Fix Ping
|
|
-- 04/27/2005 NL Add Role table and Scope table for new user permissions
|
|
-- 04/28/2005 BN Document Front Panel Information LED and Blade Information LED
|
|
-- can be powered off only
|
|
-- 05/19/2005 KS Changed warnPowerManagement to systemPowerManagement and warnBladeThrottling
|
|
-- to systemBladeThrottling. These are now system level events instead of
|
|
-- warnings.
|
|
-- 05/20/2005 BN Change ibmDirectorOverLAN(3) to ibmDiretorOverLAN(8)
|
|
-- 09/23/2005 NL Remove iscsi options from boot path
|
|
-- 10/26/2005 CSTL Modifications to remoteControlBladePowerState and remoteControlBladeHealthState
|
|
-- 01/05/2005 BN Add more generic Voltage sensors
|
|
--
|
|
-- ********************************************************************************
|
|
BLADE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE FROM RFC-1212
|
|
enterprises FROM RFC1155-SMI
|
|
-- DisplayString FROM RFC1213-MIB
|
|
IpAddress FROM RFC1155-SMI
|
|
TRAP-TYPE FROM RFC-1215;
|
|
|
|
-- IBM enterprise group
|
|
ibm OBJECT IDENTIFIER ::= { enterprises 2 }
|
|
|
|
-- IBM products group
|
|
ibmAgents OBJECT IDENTIFIER ::= { ibm 3 }
|
|
|
|
-- IBM e-Server Advanced System Management Support Processor(SP) agent group
|
|
netfinitySupportProcessorAgent OBJECT IDENTIFIER ::= { ibmAgents 51 }
|
|
|
|
-- IBM Remote Supervisor Adapter (increase this number for follow on SP's)
|
|
-- Also known as Advanced System Mangement(ASM) SP
|
|
bladeCenterSnmpMIB OBJECT IDENTIFIER ::= { netfinitySupportProcessorAgent 2 }
|
|
|
|
-- ********************************************************************************
|
|
-- Start: Define groups of objects within the bladeCenterSnmpMIB
|
|
-- ********************************************************************************
|
|
-- This group of objects provides the various environmental monitors for the
|
|
-- local system and the ASM
|
|
-- 2
|
|
monitors OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 2 }
|
|
|
|
-- This group of objects provides the error log objects for the ASM
|
|
-- 3
|
|
errorLogs OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 3 }
|
|
|
|
-- This group of objects provides configuration functions for the ASM
|
|
-- 4
|
|
configureSP OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 4 }
|
|
|
|
-- This group of objects provides system management functions for the telco
|
|
-- 5
|
|
telcoManagement OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 5 }
|
|
|
|
-- This group of objects provides configuration functions for system power
|
|
-- 6
|
|
-- systemPower OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 6 }
|
|
|
|
-- This group of objects provides functions to boot the ASM and system
|
|
-- 7
|
|
restartReset OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 7 }
|
|
|
|
-- This group of objects provides information specific to blades
|
|
-- 22
|
|
bladeCenter OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 22 }
|
|
|
|
-- This group of objects provides information on the PCI-X expansion enclosure
|
|
-- 21
|
|
-- pcixExpansionBox OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 21 }
|
|
|
|
-- ********************************************************************************
|
|
-- Temperature
|
|
-- ********************************************************************************
|
|
-- 2.1
|
|
temperature OBJECT IDENTIFIER ::= { monitors 1 }
|
|
|
|
-- Planar Temperature
|
|
-- 2.1.1
|
|
planarTemp OBJECT IDENTIFIER ::= { temperature 1 }
|
|
|
|
-- 2.1.1.2? renamed
|
|
mmTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarTemp 2 }
|
|
|
|
|
|
-- CPUx Temperature
|
|
-- 2.1.2
|
|
cpuXTemp OBJECT IDENTIFIER ::= { temperature 2 }
|
|
|
|
-- System Ambient Temperature
|
|
-- 2.1.5
|
|
ambientTemp OBJECT IDENTIFIER ::= { temperature 5 }
|
|
|
|
-- 2.1.5.1 renamed
|
|
frontPanelTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The front panel temperature in degrees centigrade(C).
|
|
This is surrounding temperature where the system is installed.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { ambientTemp 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- Voltages
|
|
-- ********************************************************************************
|
|
-- 2.2
|
|
voltage OBJECT IDENTIFIER ::= { monitors 2 }
|
|
|
|
-- Planar Voltages
|
|
-- 2.2.1
|
|
planarVolt OBJECT IDENTIFIER ::= { voltage 1 }
|
|
|
|
-- 2.2.1.1
|
|
plus5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+5 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 1 }
|
|
|
|
-- 2.2.1.2 renamed
|
|
plus3Pt3Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+3.3 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 2 }
|
|
|
|
-- 2.2.1.3
|
|
plus12Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+12 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 3 }
|
|
|
|
-- 2.2.1.4
|
|
-- minus12Volt OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "-12 Volt power supply voltage reading expressed in Volts(V).
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { planarVolt 4 }
|
|
|
|
-- 2.2.1.1
|
|
minus5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"-5 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 5 }
|
|
|
|
-- 2.2.1.6
|
|
plus2Pt5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+2.5 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 6 }
|
|
|
|
-- 2.2.1.7
|
|
-- plus1Pt5Volt OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "+1.5 Volt power supply voltage reading expressed in Volts(V).
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { planarVolt 7 }
|
|
|
|
-- 2.2.1.8
|
|
plus1Pt8Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+1.8 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 8 }
|
|
|
|
-- 2.2.1.13
|
|
-- plus1Pt25Volt OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "+1.25 Volt power supply voltage reading expressed in Volts(V).
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { planarVolt 13 }
|
|
--
|
|
-- Voltage Regulator Module Voltages
|
|
-- 2.2.3
|
|
-- vrmVolt OBJECT IDENTIFIER ::= { voltage 3 }
|
|
--
|
|
-- 2.2.3.1
|
|
-- vrm1Volt OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "VRM 1 voltage reading expressed in Volts(V).
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { vrmVolt 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blowers
|
|
-- ********************************************************************************
|
|
-- 2.3
|
|
blowers OBJECT IDENTIFIER ::= { monitors 3 }
|
|
|
|
-- 2.3.1
|
|
blower1speed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 1 speed expressed in percent(%) of maximum RPM.
|
|
An octet string expressed as 'ddd% of maximum' where:
|
|
d is a decimal digit or blank space for a leading zero.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { blowers 1 }
|
|
|
|
-- 2.3.2
|
|
blower2speed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 2 speed expressed in percent(%) of maximum RPM.
|
|
An octet string expressed as 'ddd% of maximum' where:
|
|
d is a decimal digit or blank space for a leading zero.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { blowers 2 }
|
|
|
|
-- 2.3.10
|
|
blower1State OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for blower 1.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad."
|
|
::= { blowers 10}
|
|
|
|
-- 2.3.11
|
|
blower2State OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for blower 2.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad."
|
|
::= { blowers 11}
|
|
|
|
-- ********************************************************************************
|
|
-- Power Module Health State
|
|
-- ********************************************************************************
|
|
-- 2.4
|
|
powerModuleHealth OBJECT IDENTIFIER ::= { monitors 4 }
|
|
|
|
-- 2.4.1
|
|
powerModuleHealthTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerModuleHealthEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of power module health information. Contains
|
|
the power health information for each power module."
|
|
::= { powerModuleHealth 1 }
|
|
|
|
powerModuleHealthEntry OBJECT-TYPE
|
|
SYNTAX PowerModuleHealthEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Module health entry"
|
|
INDEX { powerModuleIndex }
|
|
::= { powerModuleHealthTable 1 }
|
|
|
|
|
|
PowerModuleHealthEntry ::= SEQUENCE {
|
|
powerModuleIndex INTEGER,
|
|
powerModuleExists INTEGER,
|
|
powerModuleState INTEGER,
|
|
powerModuleDetails OCTET STRING
|
|
}
|
|
|
|
powerModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module sequence index."
|
|
::= { powerModuleHealthEntry 1 }
|
|
|
|
powerModuleExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the power module specified exists or not."
|
|
::= { powerModuleHealthEntry 2 }
|
|
|
|
powerModuleState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the power module.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = not available."
|
|
::= { powerModuleHealthEntry 3}
|
|
|
|
powerModuleDetails OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The details for this power module."
|
|
::= { powerModuleHealthEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- SP Status
|
|
-- ********************************************************************************
|
|
-- 2.5
|
|
spStatus OBJECT IDENTIFIER ::= { monitors 5 }
|
|
|
|
-- 2.5.2.1
|
|
mmBistAndChassisStatus OBJECT IDENTIFIER ::= { spStatus 2 }
|
|
|
|
|
|
bistSdram OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST DRAM test result."
|
|
::= { mmBistAndChassisStatus 1 }
|
|
|
|
bistRs485Port1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST RS 485 legacy test result."
|
|
::= { mmBistAndChassisStatus 2 }
|
|
|
|
bistRs485Port2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST RS 485 local bus test result."
|
|
::= { mmBistAndChassisStatus 3 }
|
|
|
|
bistNvram OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST NVRAM test result."
|
|
::= { mmBistAndChassisStatus 4 }
|
|
|
|
bistRtc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST RTC test result."
|
|
::= { mmBistAndChassisStatus 6 }
|
|
|
|
bistLocalI2CBus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST I2C controller test result."
|
|
::= { mmBistAndChassisStatus 7 }
|
|
|
|
bistPrimaryMainAppFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST Com 2test result."
|
|
::= { mmBistAndChassisStatus 8 }
|
|
|
|
bistSecondaryMainAppFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST Com 2test result."
|
|
::= { mmBistAndChassisStatus 9 }
|
|
|
|
bistBootRomFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST Com 2test result."
|
|
::= { mmBistAndChassisStatus 10 }
|
|
|
|
bistEthernetPort1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST external ethernet - internal wrap test result."
|
|
::= { mmBistAndChassisStatus 11 }
|
|
|
|
bistEthernetPort2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST external ethernet - external wrap test result."
|
|
::= { mmBistAndChassisStatus 12 }
|
|
|
|
bistInternalPCIBus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST I2C controller test result."
|
|
::= { mmBistAndChassisStatus 13 }
|
|
|
|
bistExternalI2CDevices OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST I2C controller test result."
|
|
::= { mmBistAndChassisStatus 14 }
|
|
|
|
bistUSBController OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST I2C controller test result."
|
|
::= { mmBistAndChassisStatus 15 }
|
|
|
|
bistVideoCompressorBoard OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST I2C controller test result."
|
|
::= { mmBistAndChassisStatus 16 }
|
|
|
|
bistPrimaryBus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST I2C controller test result."
|
|
::= { mmBistAndChassisStatus 17 }
|
|
|
|
bistInternalEthernetSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sp BIST I2C controller test result."
|
|
::= { mmBistAndChassisStatus 18 }
|
|
|
|
|
|
bistBladesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blades that are installed on the chassis.
|
|
The blades are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blades supported. If a blade is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if blades
|
|
are installed in bays 1, 5, and 13, and 14 blades are supported,
|
|
the string would look like '10001000000010'."
|
|
::= { mmBistAndChassisStatus 33 }
|
|
|
|
bistBladesCommunicating OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blades that are communicating on the chassis.
|
|
The blades are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blades supported. If a blade installed in a
|
|
bay is communicating, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if blades are communicating in bays 1, 5, and 13, and 14 blades
|
|
are supported, the string would look like '10001000000010'."
|
|
::= { mmBistAndChassisStatus 49 }
|
|
|
|
bistBlowersInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blowers that are installed on the chassis.
|
|
The blowers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blowers supported. If a blower is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if a blower
|
|
is installed in bay 1, and 2 blowers are supported, the string
|
|
would look like '10'."
|
|
::= { mmBistAndChassisStatus 65 }
|
|
|
|
bistBlowersFunctional OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blowers installed on the chassis that are functional.
|
|
The blowers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blowers supported. If a blower is installed and
|
|
functional in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if a blower is installed and functional only in bay 1, and 2 blowers
|
|
are supported, the string would look like '10'."
|
|
::= { mmBistAndChassisStatus 73 }
|
|
|
|
bistMediaTrayInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a media tray is installed on the chassis."
|
|
::= { mmBistAndChassisStatus 74 }
|
|
|
|
bistMediaTrayCommunicating OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a media tray is communicating."
|
|
::= { mmBistAndChassisStatus 75 }
|
|
|
|
bistPowerModulesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power modules that are installed on the chassis.
|
|
The power modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of power modules supported. If a power module is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if power modules are installed in bays 1 and 3, and 4 power modules
|
|
are supported, the string would look like '1010'."
|
|
::= { mmBistAndChassisStatus 81 }
|
|
|
|
bistPowerModulesFunctional OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power modules that are functional on the chassis.
|
|
The power modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of power modules supported. If a power module is
|
|
installed and functioning in a bay, a 1 is present in the string
|
|
in the position representing the bay ID as read from left to right.
|
|
For example, if power modules are installed and functioning in bays
|
|
1 and 3, and 4 power modules are supported, the string would look
|
|
like '1010'."
|
|
::= { mmBistAndChassisStatus 89 }
|
|
|
|
bistSwitchModulesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch modules that are installed on the chassis.
|
|
The switch modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of switch modules supported. If a switch module is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if switch modules are installed in bays 1 and 3, and 4 switch modules
|
|
are supported, the string would look like '1010'."
|
|
::= { mmBistAndChassisStatus 97 }
|
|
|
|
bistSwitchModulesCommunicating OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch modules that are communicating on the chassis.
|
|
The switch modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of switch modules supported. If a switch module is
|
|
installed and functioning in a bay, a 1 is present in the string
|
|
in the position representing the bay ID as read from left to right.
|
|
For example, if switch modules are installed and functioning in bays
|
|
1 and 3, and 4 switch modules are supported, the string would look
|
|
like '1010'."
|
|
::= { mmBistAndChassisStatus 113 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- System Health
|
|
-- ********************************************************************************
|
|
-- 2.7
|
|
systemHealth OBJECT IDENTIFIER ::= { monitors 7 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Health Status
|
|
-- ********************************************************************************
|
|
-- 2.7.1
|
|
systemHealthStat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(0),
|
|
nonCritical(2),
|
|
systemLevel(4),
|
|
normal(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates status of system health for the
|
|
system in which the ASM resides.
|
|
Value of 'critical' indicates a severe error has occurred
|
|
and the system may not be functioning. A value of
|
|
'nonCritical' indicates that a error has occurred but
|
|
the system is currently functioning properly.A value of
|
|
'systemLevel' indicates that a condition has occurred
|
|
that may change the state of the system in the future but currently
|
|
the system is working properly. A value of
|
|
'normal' indicates that the system is operating normally."
|
|
::= { systemHealth 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Health Summary
|
|
-- ********************************************************************************
|
|
-- 2.7.2
|
|
systemHealthSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SystemHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of System Health summary. Contains more detailed
|
|
information about the reasons for the overall system
|
|
health status.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { systemHealth 2 }
|
|
|
|
systemHealthSummaryEntry OBJECT-TYPE
|
|
SYNTAX SystemHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Health Summary entry
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
INDEX { systemHealthSummaryIndex }
|
|
::= { systemHealthSummaryTable 1 }
|
|
|
|
|
|
SystemHealthSummaryEntry ::= SEQUENCE {
|
|
systemHealthSummaryIndex INTEGER,
|
|
systemHealthSummarySeverity OCTET STRING,
|
|
systemHealthSummaryDescription OCTET STRING
|
|
}
|
|
|
|
|
|
systemHealthSummaryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary index.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { systemHealthSummaryEntry 1 }
|
|
|
|
systemHealthSummarySeverity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary severity.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { systemHealthSummaryEntry 2 }
|
|
|
|
systemHealthSummaryDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary description.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { systemHealthSummaryEntry 3 }
|
|
|
|
-- 2.7.3
|
|
-- serverBladeSystemHealthState OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- good(1),
|
|
-- noncritical(2),
|
|
-- bad(3)
|
|
-- }
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Represents blades, chassis, power supplies, management
|
|
-- modules, and switches. 1 = good, 2 = non-critical,
|
|
-- 3 = bad.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Enterprise only."
|
|
-- ::= { systemHealth 3 }
|
|
--
|
|
|
|
-- ********************************************************************************
|
|
-- LEDs
|
|
-- ********************************************************************************
|
|
leds OBJECT IDENTIFIER ::= { monitors 8 }
|
|
|
|
-- ********************************************************************************
|
|
-- Front Panel LEDs
|
|
-- ********************************************************************************
|
|
frontPanelLEDs OBJECT IDENTIFIER ::= { leds 1 }
|
|
|
|
|
|
systemErrorLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front panel system error LED is on or off.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { frontPanelLEDs 1 }
|
|
|
|
|
|
-- 3.4.8
|
|
informationLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front panel system information LED
|
|
is on or off. For Write access, the LED can be powered
|
|
off only
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { frontPanelLEDs 2 }
|
|
|
|
|
|
temperatureLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front panel temperature LED is on or off.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { frontPanelLEDs 3 }
|
|
|
|
|
|
-- 13.7
|
|
identityLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front panel identity LED is on or off.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { frontPanelLEDs 4 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Blade LEDs
|
|
-- ********************************************************************************
|
|
bladeLEDs OBJECT IDENTIFIER ::= { leds 2 }
|
|
|
|
bladeLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade status information."
|
|
::= { bladeLEDs 1 }
|
|
|
|
bladeLEDsEntry OBJECT-TYPE
|
|
SYNTAX BladeLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade system status entry"
|
|
INDEX { bladeStatusIndex }
|
|
::= { bladeLEDsTable 1 }
|
|
|
|
|
|
BladeLEDsEntry ::= SEQUENCE {
|
|
ledBladeIndex INTEGER,
|
|
ledBladeId INTEGER,
|
|
ledBladeExists INTEGER,
|
|
ledBladePowerState INTEGER,
|
|
ledBladeHealthState INTEGER,
|
|
ledBladeName OCTET STRING,
|
|
ledBladeSystemError INTEGER,
|
|
ledBladeInformation INTEGER,
|
|
ledBladeKVM INTEGER,
|
|
ledBladeMediaTray INTEGER,
|
|
ledBladeIdentity INTEGER
|
|
}
|
|
|
|
|
|
ledBladeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade LED table index."
|
|
::= { bladeLEDsEntry 1 }
|
|
|
|
ledBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeLEDsEntry 2 }
|
|
|
|
ledBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeLEDsEntry 3 }
|
|
|
|
ledBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeLEDsEntry 4 }
|
|
|
|
ledBladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade server.
|
|
1 = good, 2 = warning, 3 = bad."
|
|
::= { bladeLEDsEntry 5 }
|
|
|
|
ledBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeLEDsEntry 6 }
|
|
|
|
ledBladeSystemError OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade system error LED is on or off."
|
|
::= { bladeLEDsEntry 7 }
|
|
|
|
ledBladeInformation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade information LED is on or off.
|
|
For Write access, the LED can be powered off only."
|
|
::= { bladeLEDsEntry 8 }
|
|
|
|
ledBladeKVM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade KVM LED is on, off, or blinking."
|
|
::= { bladeLEDsEntry 9 }
|
|
|
|
ledBladeMediaTray OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade media tray LED is on, off, or blinking."
|
|
::= { bladeLEDsEntry 10 }
|
|
|
|
ledBladeIdentity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade identify LED is on, off, or blinking."
|
|
::= { bladeLEDsEntry 11 }
|
|
|
|
|
|
-- ***********************************************************************
|
|
-- Telco Panel LEDs
|
|
-- ***********************************************************************
|
|
telcoPanelLEDs OBJECT IDENTIFIER ::= { leds 3 }
|
|
|
|
|
|
-- 13.10.1
|
|
criticalLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Telco Panel CRT (Critical) LED is on or off.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoPanelLEDs 1 }
|
|
|
|
|
|
-- 13.10.2
|
|
majorLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Telco Panel MJR (Major) LED is on or off.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoPanelLEDs 2 }
|
|
|
|
-- 13.10.3
|
|
minorLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Telco Panel MNR (Minor) LED is on or off.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoPanelLEDs 3 }
|
|
|
|
|
|
-- 13.7
|
|
telcoIdentityLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Telco Panel identity LED is on or off.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoPanelLEDs 4 }
|
|
|
|
|
|
-- 13.10.6
|
|
telcoColorSel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
amber(0),
|
|
red(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Telco Critical and Major LEDs are displayed in amber or red color.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoPanelLEDs 5 }
|
|
|
|
|
|
|
|
-- 13.10.7
|
|
criticalityAssertionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Telco Criticality Assertion Mode is enable or disable.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoPanelLEDs 6 }
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Switch Module LEDs
|
|
-- ********************************************************************************
|
|
smLEDs OBJECT IDENTIFIER ::= { leds 4 }
|
|
|
|
smLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SMLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of switch module LEDs information."
|
|
::= { smLEDs 1 }
|
|
|
|
smLEDsEntry OBJECT-TYPE
|
|
SYNTAX SMLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module LEDs information entry"
|
|
INDEX { ledSMIndex }
|
|
::= { smLEDsTable 1 }
|
|
|
|
|
|
SMLEDsEntry ::= SEQUENCE {
|
|
ledSMIndex INTEGER,
|
|
ledSMLEDs OCTET STRING
|
|
}
|
|
|
|
|
|
ledSMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module LEDs table index. "
|
|
::= { smLEDsEntry 1 }
|
|
|
|
ledSMLEDs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(256))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A bitmap of LEDs information on the selected switch module. The
|
|
bitmap is a string containing a list of 1's and 0's. The
|
|
first 16 nibles represent the status of the external LEDs while the
|
|
last 16 nibles represent the status of the internal port connections
|
|
from the switch module to blades. Each nible of data is presented in
|
|
the bitmap format (0b0000) and is encoded as followed
|
|
- 0b0000: LED is not present
|
|
- 0b0001: LED is off
|
|
- 0b0010: LED is on
|
|
|
|
Note: The data is read from left to right, starting out with switch
|
|
module 1 and so on."
|
|
::= { smLEDsEntry 2 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco System Health
|
|
-- ************************************************************************
|
|
-- 2.9
|
|
telcoSystemHealth OBJECT IDENTIFIER ::= { monitors 9 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco System Health Status
|
|
-- ************************************************************************
|
|
-- 2.9.1
|
|
telcoSystemHealthStat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical-power(6),
|
|
critical(5),
|
|
major-power(4),
|
|
major(3),
|
|
minor-power(2),
|
|
minor(1),
|
|
normal(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates status of system health for the system in which the
|
|
ASM resides. Value of 'critical' indicates a non-recoverable
|
|
service affecting condition has occurred that requires an
|
|
immediate action. A value of 'major' indicates a critical
|
|
service affecting condition has occurred that requires an urgent
|
|
action. A value of 'minor' indicates a non-service affecting
|
|
condition has occurred. Corrective action should be taken in
|
|
order to prevent a more serious fault. A value of 'normal'
|
|
indicates that the system is operating normally. Severity level
|
|
with '-power' indicates the failure relates to the power resource.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoSystemHealth 1 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco System Health Summary
|
|
-- ************************************************************************
|
|
-- 2.9.2
|
|
telcoSystemHealthSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TelcoSystemHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of System Health summary. Contains more detailed
|
|
information about the reasons for the overall system
|
|
health status.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoSystemHealth 2 }
|
|
|
|
telcoSystemHealthSummaryEntry OBJECT-TYPE
|
|
SYNTAX TelcoSystemHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco System Health Summary entry.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
INDEX { telcoSystemHealthSummaryIndex }
|
|
::= { telcoSystemHealthSummaryTable 1 }
|
|
|
|
|
|
TelcoSystemHealthSummaryEntry ::= SEQUENCE {
|
|
telcoSystemHealthSummaryIndex INTEGER,
|
|
telcoSystemHealthSummarySeverity OCTET STRING,
|
|
telcoSystemHealthSummaryDescription OCTET STRING,
|
|
telcoSystemHealthSummaryEventName INTEGER,
|
|
telcoSystemHealthSummaryEventKeyID OCTET STRING,
|
|
telcoSystemHealthSummaryAcknowledge INTEGER
|
|
}
|
|
|
|
|
|
telcoSystemHealthSummaryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco System Health Summary Index.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoSystemHealthSummaryEntry 1 }
|
|
|
|
telcoSystemHealthSummarySeverity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco System Health Summary Severity. The values
|
|
and meanings are as follows:
|
|
0x06 Critical-Power
|
|
0x05 Critical
|
|
0x04 Major-Power
|
|
0x03 Major
|
|
0x02 Minor-Power
|
|
0x01 Minor
|
|
0xFF Normal
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoSystemHealthSummaryEntry 2 }
|
|
|
|
telcoSystemHealthSummaryDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco System Health Summary Description.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoSystemHealthSummaryEntry 3 }
|
|
|
|
telcoSystemHealthSummaryEventName OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco System Health Summary Event Name.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoSystemHealthSummaryEntry 4 }
|
|
|
|
telcoSystemHealthSummaryEventKeyID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco System Health Summary Event Key ID. An octet string
|
|
expressed as 'mmm:aaa:ggg:iii' where:
|
|
m : Module ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
a : Alarm ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
g : Gen ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
i : GenInfo ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoSystemHealthSummaryEntry 5 }
|
|
|
|
telcoSystemHealthSummaryAcknowledge OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unacknowledged(0),
|
|
acknowledged(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco System Health Summary Acknowledge. Indicates whether the
|
|
alarm event is acknowledged or unacknowledged.
|
|
|
|
NOTE: This MIB is for Blade Center Telco only."
|
|
::= { telcoSystemHealthSummaryEntry 6 }
|
|
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Fuel Gauge / Power Management
|
|
-- ********************************************************************************
|
|
-- 2.10
|
|
fuelGauge OBJECT IDENTIFIER ::= { monitors 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fuel Gauge
|
|
-- ********************************************************************************
|
|
fuelGaugeInformation OBJECT IDENTIFIER ::= { fuelGauge 1 }
|
|
|
|
fuelGaugeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FuelGaugeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Fuel Gauge information."
|
|
::= { fuelGaugeInformation 1 }
|
|
|
|
fuelGaugeEntry OBJECT-TYPE
|
|
SYNTAX FuelGaugeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge entry"
|
|
INDEX { fuelGaugeIndex }
|
|
::= { fuelGaugeTable 1 }
|
|
|
|
FuelGaugeEntry ::= SEQUENCE {
|
|
fuelGaugeIndex INTEGER,
|
|
fuelGaugePowerDomainNumber INTEGER,
|
|
fuelGaugeStatus OCTET STRING,
|
|
fuelGaugeFirstPowerModule OCTET STRING,
|
|
fuelGaugeSecondPowerModule OCTET STRING,
|
|
fuelGaugePowerManagementPolicySetting INTEGER,
|
|
fuelGaugeTotalPower OCTET STRING,
|
|
fuelGaugeReservedPower OCTET STRING,
|
|
fuelGaugeRemainingPower OCTET STRING,
|
|
fuelGaugePowerInUsed OCTET STRING
|
|
}
|
|
|
|
fuelGaugeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table Index."
|
|
::= { fuelGaugeEntry 1 }
|
|
|
|
fuelGaugePowerDomainNumber OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerDomain1(1),
|
|
powerDomain2(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table Power Domain Number."
|
|
::= { fuelGaugeEntry 2 }
|
|
|
|
fuelGaugeStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table Status for the power domain.
|
|
The response will start out with a numeric value (0 = unknown,
|
|
1 = good, 2 = waring, and 3: bad), followed by a text message."
|
|
::= { fuelGaugeEntry 3 }
|
|
|
|
fuelGaugeFirstPowerModule OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table First Power Module capacity in Watts in the power domain.
|
|
|
|
Note: First power module in power domain 1 and 2 is in bay 1
|
|
and 3 respectively."
|
|
::= { fuelGaugeEntry 4 }
|
|
|
|
fuelGaugeSecondPowerModule OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table Second Power Module capacity in Watts in the power domain.
|
|
|
|
Note: Second power module in power domain 1 and 2 is in bay 2
|
|
and 4 respectively."
|
|
::= { fuelGaugeEntry 5 }
|
|
|
|
fuelGaugePowerManagementPolicySetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
redundantWithoutPerformanceImpact(0),
|
|
redundantWithPerformanceImpact(1),
|
|
nonRedundant(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table for the Power Management Policy Setting for each power domain."
|
|
::= { fuelGaugeEntry 6 }
|
|
|
|
fuelGaugeTotalPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the total available power for each power domain based on
|
|
installed power modules and the current Power Management Policy Setting."
|
|
::= { fuelGaugeEntry 7 }
|
|
|
|
fuelGaugeReservedPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the power that has been reserved in each power domain.
|
|
Note: 1) Power is always reserved in domain 1 for two management modules and
|
|
two I/O modules. 2) Power is reserved for I/O modules installed in bay 3 and
|
|
4 (Powered on or standby). 3) Power is reserved for each installed Blade.
|
|
Blades in a standby state (not powered on) will reserve a certain amount power."
|
|
::= { fuelGaugeEntry 8 }
|
|
|
|
fuelGaugeRemainingPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the remaining power available in each domain.
|
|
Remaining Power = Total Power minus Power In Use "
|
|
::= { fuelGaugeEntry 9 }
|
|
|
|
fuelGaugePowerInUsed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the total power being used in each power domain."
|
|
::= { fuelGaugeEntry 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fuel Gauge Power Domain 1
|
|
-- ********************************************************************************
|
|
powerDomain1 OBJECT IDENTIFIER ::= { fuelGauge 2 }
|
|
|
|
powerDomain1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerDomain1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Power Domain 1."
|
|
::= { powerDomain1 1}
|
|
|
|
powerDomain1Entry OBJECT-TYPE
|
|
SYNTAX PowerDomain1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge entry"
|
|
INDEX { pd1Index }
|
|
::= { powerDomain1Table 1 }
|
|
|
|
|
|
PowerDomain1Entry ::= SEQUENCE {
|
|
pd1Index INTEGER,
|
|
pd1BayNumber OCTET STRING,
|
|
pd1BladePrimarySlot INTEGER,
|
|
pd1ModuleStatus INTEGER,
|
|
pd1ModuleName OCTET STRING,
|
|
pd1ModuleState INTEGER,
|
|
pd1ModuleAllocatedPowerCurrent OCTET STRING,
|
|
pd1ModuleAllocatedPowerMax OCTET STRING,
|
|
pd1ModuleAllocatedPowerMin OCTET STRING,
|
|
pd1ModuleCPUDutyCycles OCTET STRING,
|
|
pd1ModuleThrottle INTEGER
|
|
}
|
|
|
|
pd1Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Index."
|
|
::= { powerDomain1Entry 1 }
|
|
|
|
pd1BayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Bay Number.
|
|
The following Bay Number IDs are used in the BladeCenter Enterprise :
|
|
notApplicable(1),
|
|
notApplicable(2),
|
|
blowerBay1(3),
|
|
blowerBay2(4),
|
|
managementModuleBay1(5),
|
|
managementModuleBay2(6),
|
|
switchModuelBay1(7),
|
|
switchModuleBay2(8),
|
|
switchModuleBay3(9),
|
|
switchModuleBay4(10),
|
|
serverBladeBay1(11),
|
|
serverBladeBay2(12),
|
|
serverBladeBay3(13),
|
|
serverBladeBay4(14),
|
|
serverBladeBay5(15),
|
|
serverBladeBay6(16),
|
|
notApplicable(17)
|
|
The following Bay Number IDs are used in the BladeCenter T:
|
|
notApplicable(1),
|
|
notApplicable(2),
|
|
blowerBay1(3),
|
|
blowerBay2(4),
|
|
blowerBay3(5) (if Power Domain 2 is not available),
|
|
blowerBay4(6) (if Power Domain 2 is not available),
|
|
managementModuleBay1(7),
|
|
managementModuleBay2(8),
|
|
switchModuelBay1(9),
|
|
switchModuleBay2(10),
|
|
switchModuleBay3(11),
|
|
switchModuleBay4(12),
|
|
serverBladeBay1(13),
|
|
serverBladeBay2(14),
|
|
serverBladeBay3(15),
|
|
serverBladeBay4(16),
|
|
notApplicable(17)"
|
|
::= { powerDomain1Entry 2 }
|
|
|
|
pd1BladePrimarySlot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Blade Primary Slot can be useful
|
|
when a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not."
|
|
::= { powerDomain1Entry 3 }
|
|
|
|
pd1ModuleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
insufficientPower(0),
|
|
moduleIsThrottling(1),
|
|
moduleNotThrottling(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module Throttle Status."
|
|
::= { powerDomain1Entry 4 }
|
|
|
|
pd1ModuleName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module Name."
|
|
::= { powerDomain1Entry 5 }
|
|
|
|
pd1ModuleState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby(0),
|
|
on(1),
|
|
notPresent(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module State."
|
|
::= { powerDomain1Entry 6 }
|
|
|
|
pd1ModuleAllocatedPowerCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Allocated Power Current indicates the current power
|
|
allocation for the module in Watts.
|
|
|
|
Note: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the current power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain1Entry 7 }
|
|
|
|
pd1ModuleAllocatedPowerMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Allocated Power Max indicates the maximum power
|
|
allocation for the module in Watts. It is indicative of the maximum
|
|
amout of power the module will consume in the domain when it is
|
|
fully popolated with memory chips, daughter cards, etc.
|
|
|
|
Note: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the maximum power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain1Entry 8 }
|
|
|
|
pd1ModuleAllocatedPowerMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Allocated Power Min indicates the minumum power
|
|
allocation for the module in Watts. It is indicative of the minumum
|
|
power consumption of the component in the domain based on its
|
|
maximum throttle limit.
|
|
|
|
Note: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the minimum power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain1Entry 9 }
|
|
|
|
pd1ModuleCPUDutyCycles OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module CPUs Duty Cycles applies to blade
|
|
servers only. It displays the duty cycle for each CPU on the blade
|
|
as a percentage. Note that some blades do not report the CPU
|
|
duty cycles. In this case, 'notApplicable' will be displayed.
|
|
|
|
Note: The CPU duty cycles are reported only on a primary slot when
|
|
a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not.
|
|
The CPU duty cycles are reported on slot 3 while 'notApplicable'
|
|
is displayed for slot 4."
|
|
::= { powerDomain1Entry 10 }
|
|
|
|
pd1ModuleThrottle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module Throttle indicates whether the
|
|
server blade may be allowed to throttle or not."
|
|
::= { powerDomain1Entry 11 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fuel Gauge Power Domain 2
|
|
-- ********************************************************************************
|
|
powerDomain2 OBJECT IDENTIFIER ::= { fuelGauge 3 }
|
|
|
|
powerDomain2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerDomain2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Power Domain 2."
|
|
::= { powerDomain2 1 }
|
|
|
|
powerDomain2Entry OBJECT-TYPE
|
|
SYNTAX PowerDomain2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge entry"
|
|
INDEX { pd2Index }
|
|
::= { powerDomain2Table 1 }
|
|
|
|
PowerDomain2Entry ::= SEQUENCE {
|
|
pd2Index INTEGER,
|
|
pd2BayNumber OCTET STRING,
|
|
pd2BladePrimarySlot INTEGER,
|
|
pd2ModuleStatus INTEGER,
|
|
pd2ModuleName OCTET STRING,
|
|
pd2ModuleState INTEGER,
|
|
pd2ModuleAllocatedPowerCurrent OCTET STRING,
|
|
pd2ModuleAllocatedPowerMax OCTET STRING,
|
|
pd2ModuleAllocatedPowerMin OCTET STRING,
|
|
pd2ModuleCPUDutyCycles OCTET STRING,
|
|
pd2ModuleThrottle INTEGER
|
|
}
|
|
|
|
pd2Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Index."
|
|
::= { powerDomain2Entry 1 }
|
|
|
|
pd2BayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Bay Number.
|
|
The following Bay Number IDs are used in the BladeCenter Enterprise :
|
|
serverBladeBay7(1),
|
|
serverBladeBay8(2),
|
|
serverBladeBay9(3),
|
|
serverBladeBay10(4),
|
|
serverBladeBay11(5),
|
|
serverBladeBay12(6),
|
|
serverBladeBay13(7),
|
|
serverBladeBay14(8),
|
|
notApplicable(9)
|
|
The following Bay Number IDs are used in the BladeCenter T:
|
|
blowerBay3(1),
|
|
blowerBay4(2),
|
|
serverBladeBay5(3),
|
|
serverBladeBay6(4),
|
|
serverBladeBay7(5),
|
|
serverBladeBay8(6),
|
|
notApplicable(7),
|
|
notApplicable(8),
|
|
notApplicable(9)"
|
|
::= { powerDomain2Entry 2 }
|
|
|
|
pd2BladePrimarySlot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Blade Primary Slot can be useful
|
|
when a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not."
|
|
::= { powerDomain2Entry 3 }
|
|
|
|
pd2ModuleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
insufficientPower(0),
|
|
moduleIsThrottling(1),
|
|
moduleNotThrottling(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module throttle status."
|
|
::= { powerDomain2Entry 4 }
|
|
|
|
pd2ModuleName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module Name."
|
|
::= { powerDomain2Entry 5 }
|
|
|
|
pd2ModuleState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby(0),
|
|
on(1),
|
|
notPresent(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Power State."
|
|
::= { powerDomain2Entry 6 }
|
|
|
|
pd2ModuleAllocatedPowerCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Allocated Power Current indicates the current power
|
|
allocation for the module.
|
|
|
|
Note: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the current power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain2Entry 7 }
|
|
|
|
pd2ModuleAllocatedPowerMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Allocated Power Max indicates the maximum power
|
|
allocation for the module in Watts. It is indicative of the maximum
|
|
amount of power the module will consume in the domain when it is
|
|
fully popolated with memory chips, daughter cards, etc.
|
|
|
|
Note: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the maximum power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain2Entry 8 }
|
|
|
|
pd2ModuleAllocatedPowerMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Allocated Power Min indicates the minumum power
|
|
allocation for the module in Watts. It is indicative of the minumum
|
|
power consumption of the component in the domain based on its
|
|
maximum throttle limit.
|
|
|
|
Note: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the minimum power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain2Entry 9 }
|
|
|
|
pd2ModuleCPUDutyCycles OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module CPUs Duty Cycles applies to blade
|
|
servers only. It displays the duty cycle for each CPU on the blade
|
|
as a percentage. Note that some blades do not report the CPU
|
|
duty cycles. In this case, 'notApplicable' will be displayed.
|
|
|
|
Note: The CPU duty cycles are reported only on a primary slot when
|
|
a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not.
|
|
The CPU duty cycles are reported on slot 3 while 'notApplicable'
|
|
is displayed for slot 4. "
|
|
::= { powerDomain2Entry 10 }
|
|
|
|
pd2ModuleThrottle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module Throttle indicates whether the
|
|
server blade may be allowed to throttle or not."
|
|
::= { powerDomain2Entry 11 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Error logs
|
|
-- ********************************************************************************
|
|
-- 3.4
|
|
eventLog OBJECT IDENTIFIER ::= { errorLogs 4 }
|
|
|
|
-- 3.4.6
|
|
readEventLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ReadEventLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of event log entry information."
|
|
::= { eventLog 2 }
|
|
|
|
readEventLogEntry OBJECT-TYPE
|
|
SYNTAX ReadEventLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Event log entry table entry"
|
|
INDEX { readEventLogIndex }
|
|
::= { readEventLogTable 1 }
|
|
|
|
|
|
ReadEventLogEntry ::= SEQUENCE {
|
|
readEventLogIndex INTEGER,
|
|
readEventLogString OCTET STRING
|
|
}
|
|
|
|
|
|
readEventLogIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The event log index number. For consistent results,
|
|
view as a table and not as individual entries."
|
|
::= { readEventLogEntry 1 }
|
|
|
|
readEventLogString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing an event. For consistent
|
|
results, view as a table and not as individual entries."
|
|
::= { readEventLogEntry 2 }
|
|
|
|
|
|
-- 3.4.3
|
|
clearEventLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear the event log.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB."
|
|
::= { eventLog 3 }
|
|
|
|
-- 3.4.4
|
|
monitorLogStateEvents OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If disabled, it means the info LED will not turn on when the log gets full
|
|
and no alerts will be sent out. If enabled, the LED will turn on when the log
|
|
gets full and alerts will be sent out."
|
|
::= { eventLog 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- Event Log Information
|
|
-- ********************************************************************************
|
|
-- 3.4, 3.5 this looks like 3.1 and 3.4.1, but might be all that's needed.
|
|
-- eventLog OBJECT IDENTIFIER ::= { errorLogs 4 }
|
|
--
|
|
-- eventLogTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF EventLogEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Table of event logs."
|
|
-- ::= { eventLog 2 }
|
|
--
|
|
-- eventLogEntry OBJECT-TYPE
|
|
-- SYNTAX EventLogEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Event log entries."
|
|
-- INDEX { eventLogIndex }
|
|
-- ::= { eventLogTable 1 }
|
|
--
|
|
--
|
|
-- EventLogEntry ::= SEQUENCE {
|
|
-- eventLogIndex INTEGER,
|
|
-- eventLogString DisplayString
|
|
-- }
|
|
--
|
|
--
|
|
-- eventLogIndex OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Event log index number."
|
|
-- ::= { eventLogEntry 1 }
|
|
--
|
|
-- eventLogString OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(0..8))
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Contains a string of information to detail the event."
|
|
-- ::= { eventLogEntry 2}
|
|
--
|
|
--
|
|
-- 3.4.3, 3.5.3
|
|
-- eventLogClr OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- execute(1)
|
|
-- }
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Clear the event log.
|
|
--
|
|
-- NOTE: Value returned by the GET command is meaningless for this
|
|
-- MIB object."
|
|
-- ::= { eventLog 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- Configure the ASM
|
|
-- ********************************************************************************
|
|
-- ********************************************************************************
|
|
-- Remote Access Configuration
|
|
-- ********************************************************************************
|
|
-- 4.1
|
|
remoteAccessConfig OBJECT IDENTIFIER ::= { configureSP 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- General Remote Access and Remote Alerts Configuration
|
|
-- ********************************************************************************
|
|
generalRemoteCfg OBJECT IDENTIFIER ::= { remoteAccessConfig 1 }
|
|
|
|
remoteAlertRetryCount OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noretry(0),
|
|
retry1(1),
|
|
retry2(2),
|
|
retry3(3),
|
|
retry4(4),
|
|
retry5(5),
|
|
retry6(6),
|
|
retry7(7),
|
|
retry8(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of additional times a remote alert will be
|
|
retried if not succesfully sent. A value of zero indicates
|
|
no retries will be attempted."
|
|
::= { generalRemoteCfg 4 }
|
|
|
|
remoteAlertRetryDelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noDelay(0),
|
|
oneHalfMinute(30),
|
|
oneMinute(60),
|
|
oneAndHalfMinutes(90),
|
|
twoMinutes(120),
|
|
twoAndHalfMinutes(150),
|
|
threeMinutes(180),
|
|
threeAndHalfMinutes(210),
|
|
fourMinutes(240)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number in seconds to delay between retries if sending a
|
|
remote alert is unsuccessful."
|
|
::= { generalRemoteCfg 5 }
|
|
|
|
remoteAccessTamperDelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nowait(0),
|
|
oneMinute(1),
|
|
twoMinutes(2),
|
|
threeMinutes(3),
|
|
fourMinutes(4),
|
|
fiveMinutes(5),
|
|
sixMinutes(6),
|
|
sevenMinutes(7),
|
|
tenMinutes(10),
|
|
fifteenMinutes(15),
|
|
twentyMinutes(20),
|
|
thirtyMinutes(30),
|
|
sixtyMinutes(60),
|
|
oneTwentyMinutes(120),
|
|
oneEightyMinutes(180),
|
|
twoFortyMinutes(240)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number in minutes to prohibit a remote login attempt
|
|
after more than 5 sequential login attempts have failed."
|
|
::= { generalRemoteCfg 6 }
|
|
|
|
|
|
userAuthenticationMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
localOnly(0),
|
|
ldapOnly(1),
|
|
localFirstThenLdap(2),
|
|
ldapFirstThenLocal(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Use this field to specify how users attempting to login should be authenticated.
|
|
There are two methods:
|
|
Local authentication. Userid and password are verified by searching the list
|
|
of users locally configured under Local Login Profiles.
|
|
LDAP based authentication. Users are authenticated via a remote LDAP server.
|
|
One or both authentication methods can be selected. If both methods should be
|
|
used, the order must be specified."
|
|
::= { generalRemoteCfg 7 }
|
|
|
|
allowModemLogin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allow the user login through modem connection"
|
|
::= { generalRemoteCfg 8 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert Profiles
|
|
-- ********************************************************************************
|
|
-- 4.1.3
|
|
remoteAlertIds OBJECT IDENTIFIER ::= { remoteAccessConfig 3 }
|
|
|
|
remoteAlertIdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAlertIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of remote alert entries.
|
|
This table lets you configure remote alert recipients.
|
|
You can define up to 12 unique recipients.
|
|
Note: All selected alert events will be sent to all
|
|
enabled alert recipients."
|
|
::= { remoteAlertIds 1 }
|
|
|
|
remoteAlertIdsEntry OBJECT-TYPE
|
|
SYNTAX RemoteAlertIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote alert entries."
|
|
INDEX { remoteAlertIdEntryIndex }
|
|
::= { remoteAlertIdsTable 1 }
|
|
|
|
|
|
RemoteAlertIdsEntry ::= SEQUENCE {
|
|
remoteAlertIdEntryIndex INTEGER,
|
|
remoteAlertIdEntryStatus INTEGER,
|
|
remoteAlertIdEntryIpOrHostAddress OCTET STRING (SIZE(0..50)),
|
|
remoteAlertIdEntryTextDescription OCTET STRING (SIZE(0..32)),
|
|
remoteAlertIdEntryNotificationType INTEGER,
|
|
remoteAlertIdEmailAddr OCTET STRING (SIZE(0..64)),
|
|
remoteAlertIdEntrySelectiveAlert INTEGER
|
|
}
|
|
|
|
|
|
remoteAlertIdEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for remote alert entry."
|
|
::= { remoteAlertIdsEntry 1 }
|
|
|
|
-- 4.1.3.x.1
|
|
remoteAlertIdEntryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(0),
|
|
disabledAndValid(1),
|
|
enabledAndValid(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote alert entry status, invalid means entry
|
|
not defined yet, disabledAndValid means entry defined
|
|
but not enabled to send an alert, enabledAndValid means
|
|
entry defined and enabled to send an alert."
|
|
::= { remoteAlertIdsEntry 2 }
|
|
|
|
-- 4.1.3.x.2
|
|
remoteAlertIdEntryIpOrHostAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A null terminated string that either
|
|
contains an IP address of the form '1.2.3.4'
|
|
or a host name (if DNS is enabled) for the
|
|
alert entry."
|
|
::= { remoteAlertIdsEntry 3 }
|
|
|
|
-- 4.1.3.x.3
|
|
remoteAlertIdEntryTextDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A null terminated string that contains
|
|
a text description of this entry."
|
|
::= { remoteAlertIdsEntry 4 }
|
|
|
|
-- 4.1.3.x.4
|
|
remoteAlertIdEntryNotificationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ibmDirectorOverLAN(8),
|
|
snmpOverLan(4),
|
|
emailOverLan(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote alert entry notification method. Types include
|
|
unknown when the type can't be determined (read-only),
|
|
ibmDirectorOverLAN for a LAN alert sent over ethernet to
|
|
IBM director, snmpOverLan for an SNMP alert over ethernet,
|
|
and emailOverLan for a E-Mail alert over ethernet."
|
|
::= { remoteAlertIdsEntry 5 }
|
|
|
|
-- 4.1.3.x.8
|
|
remoteAlertIdEmailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A null terminated string that contains an
|
|
E-Mail Address. For example, 'jeb@us.ibm.com'.
|
|
Used only for an E-mail over Lan or E-Mail over PPP
|
|
notification type."
|
|
::= { remoteAlertIdsEntry 9 }
|
|
|
|
-- 4.1.3.x.12
|
|
remoteAlertIdEntrySelectiveAlert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critOnlyAlerts(0),
|
|
allAlerts(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote alert entry selective alert setting. A value of
|
|
critOnlyAlerts will only send critical alerts to this
|
|
remote alert receipient, a value of allAlerts will send
|
|
all alerts to this remote alert recepient."
|
|
::= { remoteAlertIdsEntry 13 }
|
|
|
|
-- not in cmds doc
|
|
generateTestAlert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate a Test Alert. This will send a test alert to all configured
|
|
and enabled remote alert receipients. The text portion of the alert
|
|
will contain 'Application Posted Alert to ASM'.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB."
|
|
::= { remoteAlertIds 30 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Access Profiles
|
|
-- ********************************************************************************
|
|
-- 4.1.4
|
|
remoteAccessIds OBJECT IDENTIFIER ::= { remoteAccessConfig 4 }
|
|
|
|
-- 4.1.4.x
|
|
remoteAccessIdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAccessIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of remote access profiles.
|
|
|
|
This table lets you to configure all login profiles.
|
|
You can define up to 12 unique profiles.
|
|
|
|
Note: By default, the remote supervisor adapter
|
|
comes configured with one login profile that allows remote
|
|
access using a login ID of 'USERID' and a password of 'PASSW0RD'
|
|
(the 0 is a zero). To avoid a potential security exposure,
|
|
we strongly recommend that you change this default Login
|
|
Profile to values of your choice."
|
|
::= { remoteAccessIds 1 }
|
|
|
|
remoteAccessIdsEntry OBJECT-TYPE
|
|
SYNTAX RemoteAccessIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote access entries."
|
|
INDEX { remoteAccessIdEntryIndex }
|
|
::= { remoteAccessIdsTable 1 }
|
|
|
|
|
|
RemoteAccessIdsEntry ::= SEQUENCE {
|
|
remoteAccessIdEntryIndex INTEGER(0..255),
|
|
remoteAccessIdEntryUserId OCTET STRING (SIZE(0..16)),
|
|
remoteAccessIdEntryPassword OCTET STRING (SIZE(0..16)),
|
|
-- remoteAccessIdLastAccess OCTET STRING (SIZE(7)),
|
|
-- remoteAccessIdEntryAccessFlags INTEGER,
|
|
-- remoteAccessIdEntryDialBackPhoneNum OCTET STRING (SIZE(0..40)),
|
|
remoteAccessIdEntryEncodedLoginPw OCTET STRING (SIZE(0..36))
|
|
-- remoteAccessIdEntryLastFloppyRemoteBoot OCTET STRING (SIZE(0..16)),
|
|
-- remoteAccessIdEntryLastTempDirRemoteBoot OCTET STRING (SIZE(0..256))
|
|
}
|
|
|
|
|
|
remoteAccessIdEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for Remote access entry."
|
|
::= { remoteAccessIdsEntry 1 }
|
|
|
|
-- 4.1.4.x.1
|
|
remoteAccessIdEntryUserId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote access entry null terminated string that
|
|
contains the user-id. It must not be a duplicate of
|
|
any previously configured ones."
|
|
::= { remoteAccessIdsEntry 2 }
|
|
|
|
-- 4.1.4.x.2
|
|
remoteAccessIdEntryPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote access password. The password must
|
|
contain at least one alphabetic and one
|
|
non-alphabetic character and be at least 5
|
|
characters long, or you can leave the password
|
|
field blank to set an empty password.
|
|
|
|
NOTE: Value returned by the GET command is meaningless
|
|
for this MIB object."
|
|
::= { remoteAccessIdsEntry 3 }
|
|
|
|
-- temporarily removed
|
|
-- 4.1.4.x.3
|
|
-- remoteAccessIdLastAccess OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(7))
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Date and time of last login. On a write, this
|
|
-- field has no effect."
|
|
-- ::= { remoteAccessIdsEntry 4 }
|
|
|
|
-- 4.1.4.x.4
|
|
-- remoteAccessIdEntryAccessFlags OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- readWriteEnabled(0),
|
|
-- readOnlyEnabled(1)
|
|
-- }
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Remote access permission."
|
|
-- ::= { remoteAccessIdsEntry 5 }
|
|
|
|
-- 4.1.4.x.6
|
|
remoteAccessIdEntryEncodedLoginPw OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..36))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Used only for configuration save/restore.
|
|
A null terminated string containing an encoded
|
|
concatenation of the login ID and password
|
|
separated by an ':'."
|
|
::= { remoteAccessIdsEntry 7 }
|
|
|
|
-- temporarily removed
|
|
-- 4.1.4.x.7
|
|
-- remoteAccessIdEntryLastFloppyRemoteBoot OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(0..16))
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The last drive used for remote booting."
|
|
-- ::= { remoteAccessIdsEntry 8 }
|
|
--
|
|
-- 4.1.4.x.8
|
|
-- remoteAccessIdEntryLastTempDirRemoteBoot OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(0..256))
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The temporary directory used for remote booting."
|
|
-- ::= { remoteAccessIdsEntry 9 }
|
|
|
|
-- 51.1.4.1.4.2
|
|
remoteAccessUserAuthorityLevelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAccessUserAuthorityLevelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of user authority level profiles."
|
|
::= { remoteAccessIds 2 }
|
|
|
|
remoteAccessUserAuthorityLevelEntry OBJECT-TYPE
|
|
SYNTAX RemoteAccessUserAuthorityLevelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User authority level entries."
|
|
INDEX { ualIndex }
|
|
::= { remoteAccessUserAuthorityLevelTable 1 }
|
|
|
|
RemoteAccessUserAuthorityLevelEntry ::= SEQUENCE {
|
|
ualIndex INTEGER(0..255),
|
|
ualId OCTET STRING (SIZE(0..16)),
|
|
ualSupervisor INTEGER,
|
|
ualReadOnly INTEGER,
|
|
ualAccountManagement INTEGER,
|
|
ualConsoleAccess INTEGER,
|
|
ualConsoleAndVirtualMediaAccess INTEGER,
|
|
ualServerPowerAccess INTEGER,
|
|
ualAllowClearLog INTEGER,
|
|
ualAdapterBasicConfig INTEGER,
|
|
ualAdapterNetworkAndSecurityConfig INTEGER,
|
|
ualAdapterAdvancedConfig INTEGER
|
|
}
|
|
|
|
ualIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for User Authority Level entry."
|
|
::= { remoteAccessUserAuthorityLevelEntry 1 }
|
|
|
|
ualId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User ID"
|
|
::= { remoteAccessUserAuthorityLevelEntry 2 }
|
|
|
|
ualSupervisor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has no restrictions."
|
|
::= { remoteAccessUserAuthorityLevelEntry 3 }
|
|
|
|
ualReadOnly OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has only read-only access, and cannot perform any save, modify,
|
|
clear, or state affecting operations (eg. restart ASM, restore defaults,
|
|
upgrade the firmware, etc.)."
|
|
::= { remoteAccessUserAuthorityLevelEntry 4 }
|
|
|
|
ualAccountManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can add/modify/delete users and change the global login settings in
|
|
the Login Profiles panel."
|
|
::= { remoteAccessUserAuthorityLevelEntry 5 }
|
|
|
|
ualConsoleAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can access the remote console."
|
|
::= { remoteAccessUserAuthorityLevelEntry 6 }
|
|
|
|
ualConsoleAndVirtualMediaAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can access both the remote console and the virtual media feature."
|
|
::= { remoteAccessUserAuthorityLevelEntry 7 }
|
|
|
|
ualServerPowerAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can access the power on and restart functions for the remote server.
|
|
These functions are available via the Power/Restart panel."
|
|
::= { remoteAccessUserAuthorityLevelEntry 8 }
|
|
|
|
ualAllowClearLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can clear the event logs. Everyone can look at the
|
|
event logs, but this particular permission is required to clear the logs."
|
|
::= { remoteAccessUserAuthorityLevelEntry 9 }
|
|
|
|
ualAdapterBasicConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify configuration parameters in the System Settings and Alerts
|
|
panels."
|
|
::= { remoteAccessUserAuthorityLevelEntry 10 }
|
|
|
|
ualAdapterNetworkAndSecurityConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify configuration parameters in the Security, Network Protocols,
|
|
Network Interface, Port Assignments, and Serial Port panels."
|
|
::= { remoteAccessUserAuthorityLevelEntry 11 }
|
|
|
|
ualAdapterAdvancedConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has no restrictions when configuring the adapter. In addition, the
|
|
user is said to have administrative access to the RSA, meaning that the
|
|
user can also perform the following advanced functions: firmware upgrades,
|
|
PXE network boot, restore adapter factory defaults, modify and restore
|
|
adapter configuration from a configuration file, and restart/reset the
|
|
adapter."
|
|
::= { remoteAccessUserAuthorityLevelEntry 12 }
|
|
|
|
|
|
-- 51.2.4.1.4.3
|
|
remoteAccessRBSroleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAccessRBSroleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of RBS User Role profiles."
|
|
::= { remoteAccessIds 3 }
|
|
|
|
remoteAccessRBSroleEntry OBJECT-TYPE
|
|
SYNTAX RemoteAccessRBSroleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Role entries."
|
|
INDEX { roleIndex }
|
|
::= { remoteAccessRBSroleTable 1 }
|
|
|
|
RemoteAccessRBSroleEntry ::= SEQUENCE {
|
|
roleIndex INTEGER(0..255),
|
|
roleId OCTET STRING (SIZE(0..16)),
|
|
rbsSupervisor INTEGER,
|
|
rbsOperator INTEGER,
|
|
rbsChassisOperator INTEGER,
|
|
rbsChassisAccountManagement INTEGER,
|
|
rbsChassisLogManagement INTEGER,
|
|
rbsChassisConfiguration INTEGER,
|
|
rbsChassisAdministration INTEGER,
|
|
rbsBladeOperator INTEGER,
|
|
rbsBladeRemotePresence INTEGER,
|
|
rbsBladeConfiguration INTEGER,
|
|
rbsBladeAdministration INTEGER,
|
|
rbsSwitchModuleOperator INTEGER,
|
|
rbsSwitchModuleConfiguration INTEGER,
|
|
rbsSwitchModuleAdministration INTEGER
|
|
}
|
|
|
|
|
|
roleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for RBS User Role entry."
|
|
::= { remoteAccessRBSroleEntry 1 }
|
|
|
|
roleId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User ID"
|
|
::= { remoteAccessRBSroleEntry 2 }
|
|
|
|
rbsSupervisor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has no restrictions."
|
|
::= { remoteAccessRBSroleEntry 3 }
|
|
|
|
rbsOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has only operator access, and cannot perform
|
|
any save, modify, clear, or state affecting operations
|
|
(eg. restart ASM, restore defaults, upgrade the firmware,
|
|
etc.)."
|
|
::= { remoteAccessRBSroleEntry 4 }
|
|
|
|
rbsChassisOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to browse status and properties of
|
|
chassis components (MM, blowers, midplane, power modules,
|
|
media tray."
|
|
::= { remoteAccessRBSroleEntry 5 }
|
|
|
|
|
|
rbsChassisAccountManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can add/modify/delete users and change the
|
|
global login settings."
|
|
::= { remoteAccessRBSroleEntry 6 }
|
|
|
|
rbsChassisLogManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to clear the MM event log and to change
|
|
log policy settings."
|
|
::= { remoteAccessRBSroleEntry 7 }
|
|
|
|
rbsChassisConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify and save any chassis configuration
|
|
parameter (except user profiles and event log settings.)"
|
|
::= { remoteAccessRBSroleEntry 8 }
|
|
|
|
rbsChassisAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to backup or restore MM configuration,
|
|
do MM firmware updates, restore MM factory defaults
|
|
configuration, or restart the MM.)"
|
|
::= { remoteAccessRBSroleEntry 9 }
|
|
|
|
rbsBladeOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to browse status and properties of
|
|
blades."
|
|
::= { remoteAccessRBSroleEntry 10 }
|
|
|
|
rbsBladeRemotePresence OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to access the Remote Control web panel
|
|
and the functions provided on the panel: remote console
|
|
(KVM) and remote disk. The ability to issue the CLI
|
|
console command to start an SOL session to a blade will
|
|
also require this authority."
|
|
::= { remoteAccessRBSroleEntry 11 }
|
|
|
|
rbsBladeConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify and save any blade configuration
|
|
parameter."
|
|
::= { remoteAccessRBSroleEntry 12 }
|
|
|
|
rbsBladeAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can power on/off and restart blades, activate
|
|
standby blade servers, do firmware updates."
|
|
::= { remoteAccessRBSroleEntry 13 }
|
|
|
|
rbsSwitchModuleOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to browse status and properties of
|
|
I/O modules."
|
|
::= { remoteAccessRBSroleEntry 14 }
|
|
|
|
rbsSwitchModuleConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify the switch module configuration
|
|
parameters on the Switch Management."
|
|
::= { remoteAccessRBSroleEntry 15 }
|
|
|
|
rbsSwitchModuleAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can power on/off and restart the switch modules,
|
|
and update switch module firmware."
|
|
::= { remoteAccessRBSroleEntry 16 }
|
|
|
|
|
|
-- 51.2.4.1.4.4
|
|
remoteAccessRBSscopeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAccessRBSscopeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of RBS User Scope profiles."
|
|
::= { remoteAccessIds 4 }
|
|
|
|
remoteAccessRBSscopeEntry OBJECT-TYPE
|
|
SYNTAX RemoteAccessRBSscopeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Scope entries."
|
|
INDEX { scopeIndex }
|
|
::= { remoteAccessRBSscopeTable 1 }
|
|
|
|
RemoteAccessRBSscopeEntry ::= SEQUENCE {
|
|
scopeIndex INTEGER(0..255),
|
|
scopeId OCTET STRING (SIZE(0..16)),
|
|
rbsChassis INTEGER,
|
|
rbsBlade1 INTEGER,
|
|
rbsBlade2 INTEGER,
|
|
rbsBlade3 INTEGER,
|
|
rbsBlade4 INTEGER,
|
|
rbsBlade5 INTEGER,
|
|
rbsBlade6 INTEGER,
|
|
rbsBlade7 INTEGER,
|
|
rbsBlade8 INTEGER,
|
|
rbsBlade9 INTEGER,
|
|
rbsBlade10 INTEGER,
|
|
rbsBlade11 INTEGER,
|
|
rbsBlade12 INTEGER,
|
|
rbsBlade13 INTEGER,
|
|
rbsBlade14 INTEGER,
|
|
rbsSwitch1 INTEGER,
|
|
rbsSwitch2 INTEGER,
|
|
rbsSwitch3 INTEGER,
|
|
rbsSwitch4 INTEGER
|
|
}
|
|
|
|
|
|
scopeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for RBS User Scope Entry."
|
|
::= { remoteAccessRBSscopeEntry 1 }
|
|
|
|
scopeId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User ID"
|
|
::= { remoteAccessRBSscopeEntry 2 }
|
|
|
|
rbsChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the MM and chassis functions."
|
|
::= { remoteAccessRBSscopeEntry 3 }
|
|
|
|
rbsBlade1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 1."
|
|
::= { remoteAccessRBSscopeEntry 4 }
|
|
|
|
rbsBlade2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 2."
|
|
::= { remoteAccessRBSscopeEntry 5 }
|
|
|
|
|
|
rbsBlade3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 3."
|
|
::= { remoteAccessRBSscopeEntry 6 }
|
|
|
|
rbsBlade4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 4."
|
|
::= { remoteAccessRBSscopeEntry 7 }
|
|
|
|
rbsBlade5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 5."
|
|
::= { remoteAccessRBSscopeEntry 8 }
|
|
|
|
rbsBlade6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 6."
|
|
::= { remoteAccessRBSscopeEntry 9 }
|
|
|
|
rbsBlade7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 7."
|
|
::= { remoteAccessRBSscopeEntry 10 }
|
|
|
|
|
|
rbsBlade8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 8."
|
|
::= { remoteAccessRBSscopeEntry 11 }
|
|
|
|
rbsBlade9 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 9."
|
|
::= { remoteAccessRBSscopeEntry 12 }
|
|
|
|
rbsBlade10 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 10."
|
|
::= { remoteAccessRBSscopeEntry 13 }
|
|
|
|
rbsBlade11 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 11."
|
|
::= { remoteAccessRBSscopeEntry 14 }
|
|
|
|
rbsBlade12 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 12."
|
|
::= { remoteAccessRBSscopeEntry 15 }
|
|
|
|
|
|
rbsBlade13 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 13."
|
|
::= { remoteAccessRBSscopeEntry 16 }
|
|
|
|
rbsBlade14 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 14."
|
|
::= { remoteAccessRBSscopeEntry 17 }
|
|
|
|
rbsSwitch1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to switch module 1."
|
|
::= { remoteAccessRBSscopeEntry 18 }
|
|
|
|
rbsSwitch2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to switch module 2."
|
|
::= { remoteAccessRBSscopeEntry 19 }
|
|
|
|
rbsSwitch3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to switch module 3."
|
|
::= { remoteAccessRBSscopeEntry 20 }
|
|
|
|
rbsSwitch4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to switch module 4."
|
|
::= { remoteAccessRBSscopeEntry 21 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert types
|
|
-- ********************************************************************************
|
|
-- 4.2
|
|
remoteAlerts OBJECT IDENTIFIER ::= { configureSP 2 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert Critical Error types
|
|
-- ********************************************************************************
|
|
-- 4.2.1
|
|
remoteAlertsCrit OBJECT IDENTIFIER ::= { remoteAlerts 1 }
|
|
|
|
-- 4.2.1.1
|
|
critTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of the monitored temperature sensors
|
|
in the system exceed their critical threshold.
|
|
|
|
Note: If a critical Temperature condition is detected,
|
|
the server will automatically be shut down and powered off
|
|
whether this object is enabled or not."
|
|
::= { remoteAlertsCrit 1 }
|
|
|
|
-- 4.2.1.2
|
|
critVolt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate a alert if any of the monitored power supply sensors
|
|
in the system fall outside their specified critical
|
|
operational range.
|
|
|
|
Note: If a critical voltage condition is detected,
|
|
the server will automatically be shut down and powered off
|
|
whether this object is enabled or not."
|
|
::= { remoteAlertsCrit 2 }
|
|
|
|
|
|
-- 4.2.1.4
|
|
critMultiBlower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if multiple blowers used for cooling the system fail."
|
|
::= { remoteAlertsCrit 4 }
|
|
|
|
-- 4.2.1.5
|
|
critPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of the system power supplies fail."
|
|
::= { remoteAlertsCrit 5 }
|
|
|
|
-- 4.2.1.6
|
|
critHardDrive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of hard disk drives fail."
|
|
::= { remoteAlertsCrit 6 }
|
|
|
|
-- 4.2.1.7
|
|
critVRM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of VRM (voltage regulator modules) fail."
|
|
::= { remoteAlertsCrit 7 }
|
|
|
|
|
|
-- 4.2.1.8
|
|
critMultipleSwitchModule OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if all switch modules fail or are removed."
|
|
::= { remoteAlertsCrit 8 }
|
|
|
|
-- 4.2.1.9
|
|
critInvalidConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the hardware configuration is incompatible."
|
|
::= { remoteAlertsCrit 9 }
|
|
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert Warning(non-critical) Error types
|
|
-- ********************************************************************************
|
|
-- 4.2.2
|
|
remoteAlertsNonCrit OBJECT IDENTIFIER ::= { remoteAlerts 2 }
|
|
|
|
-- 4.2.2.2
|
|
warnSingleBlower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if one blower used for cooling the system fails."
|
|
::= { remoteAlertsNonCrit 2 }
|
|
|
|
-- 4.2.2.3
|
|
warnTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of the monitored temperature sensors
|
|
in the system exceed their warning threshold."
|
|
::= { remoteAlertsNonCrit 3 }
|
|
|
|
-- 4.2.2.4
|
|
warnVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of the monitored power supply sensors
|
|
in the system fall outside their specified warning operational range."
|
|
::= { remoteAlertsNonCrit 4 }
|
|
|
|
-- 4.2.2.6
|
|
warnRedundantModule OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of the switch modules or management
|
|
modules is failing or removed."
|
|
::= { remoteAlertsNonCrit 6 }
|
|
|
|
-- 4.2.2.7
|
|
warnMediaTrayKVMSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the system detects a Media Tray or KVM
|
|
switching failure."
|
|
::= { remoteAlertsNonCrit 7 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert System Error types
|
|
-- ********************************************************************************
|
|
-- 4.2.3
|
|
remoteAlertsSystem OBJECT IDENTIFIER ::= { remoteAlerts 3 }
|
|
|
|
|
|
-- 4.2.3.4
|
|
systemPowerOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the system is powered off."
|
|
::= { remoteAlertsSystem 4 }
|
|
|
|
-- 4.2.3.5
|
|
systemPowerOn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate a alert if the system is powered on."
|
|
::= { remoteAlertsSystem 5 }
|
|
|
|
-- 4.2.3.8
|
|
systemPFA OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate a alert if the system hardware detects a Predictive
|
|
Failure Analysis(PFA) on PFA enabled hardware."
|
|
::= { remoteAlertsSystem 8 }
|
|
|
|
-- 4.2.3.10
|
|
systemInventory OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the a processor blade or media tray is
|
|
added or removed."
|
|
::= { remoteAlertsSystem 10 }
|
|
|
|
-- 4.2.3.11
|
|
systemLog75PctFull OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the system log reaches 75% full."
|
|
::= { remoteAlertsSystem 11 }
|
|
|
|
-- 4.2.3.12
|
|
networkChangeNotification OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the SP has restarted and the internal
|
|
network has initialized successfully, or if an IP address
|
|
change via a source other than the management module."
|
|
::= { remoteAlertsSystem 12 }
|
|
|
|
-- 4.2.3.13
|
|
systemBladeThrottling OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of the server blades are throttling."
|
|
::= { remoteAlertsSystem 13 }
|
|
|
|
-- 4.2.3.14
|
|
systemPowerManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the system detects a power oversubscription
|
|
condition or power supply mismatch in a power domain."
|
|
::= { remoteAlertsSystem 14 }
|
|
|
|
-- ********************************************************************************
|
|
-- Environmental Monitor Thresholds
|
|
-- ********************************************************************************
|
|
-- 4.3.2
|
|
monitorThresholds OBJECT IDENTIFIER ::= { monitors 20 }
|
|
|
|
-- ********************************************************************************
|
|
-- Temperature Thresholds
|
|
-- ********************************************************************************
|
|
-- 4.3.2.1
|
|
-- tempThresholds OBJECT IDENTIFIER ::= { monitorThresholds 1 }
|
|
--
|
|
--
|
|
-- 4.3.2.1.1
|
|
-- generalSystemTempThresholds OBJECT IDENTIFIER ::= { tempThresholds 1 }
|
|
--
|
|
--
|
|
-- generalTempThresholdsTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF GeneralTempThresholdsEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Table of General Temperature threshold entries.
|
|
-- Has information about the Planar temperature and
|
|
-- System Ambient temperature."
|
|
-- ::= { generalSystemTempThresholds 1 }
|
|
--
|
|
-- generalTempThresholdsEntry OBJECT-TYPE
|
|
-- SYNTAX GeneralTempThresholdsEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "General Temperature threshold entries."
|
|
-- INDEX { generalTempThresholdEntryIndex }
|
|
-- ::= { generalTempThresholdsTable 1 }
|
|
--
|
|
-- GeneralTempThresholdsEntry ::= SEQUENCE {
|
|
-- generalTempThresholdEntryIndex INTEGER(0..255),
|
|
-- generalTempThresholdEntryName OCTET STRING (SIZE(0..16)),
|
|
-- generalTempThresholdEntryCurrentValue OCTET STRING,
|
|
-- generalTempThresholdEntryHardShutdownValue OCTET STRING,
|
|
-- generalTempThresholdEntrySoftShutdownValue OCTET STRING,
|
|
-- generalTempThresholdEntryWarningValue OCTET STRING,
|
|
-- generalTempThresholdEntryWarningResetValue OCTET STRING
|
|
-- }
|
|
--
|
|
--
|
|
-- generalTempThresholdEntryIndex OBJECT-TYPE
|
|
-- SYNTAX INTEGER(0..255)
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Index for a general temperature threshold entry."
|
|
-- ::= { generalTempThresholdsEntry 1 }
|
|
--
|
|
-- generalTempThresholdEntryName OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(0..16))
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Null terminated string that
|
|
-- contains the individual temperature monitor's name."
|
|
-- ::= { generalTempThresholdsEntry 2 }
|
|
--
|
|
-- generalTempThresholdEntryCurrentValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Temperature in degrees centigrade(C).
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or blank space for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { generalTempThresholdsEntry 3 }
|
|
--
|
|
-- 4.3.2.1.1.1
|
|
-- generalTempThresholdEntryHardShutdownValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Temperature in degrees centigrade(C).
|
|
-- If the component's temperature rises above this value the
|
|
-- system will be powered off immediately.
|
|
-- If enabled, a critical alert/event will be generated.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or blank space for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { generalTempThresholdsEntry 4 }
|
|
--
|
|
-- 4.3.2.1.1.2
|
|
-- generalTempThresholdEntrySoftShutdownValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Temperature in degrees centigrade(C).
|
|
-- If the component's temperature rises above this value the
|
|
-- system will be powered off after the O/S is shut down.
|
|
-- If enabled, a critical alert/event is generated.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or blank space for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { generalTempThresholdsEntry 5 }
|
|
--
|
|
-- 4.3.2.1.1.3
|
|
-- generalTempThresholdEntryWarningValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Temperature in degrees centigrade(C).
|
|
-- If the temperature rises above this value a warning alert/event
|
|
-- if enabled will be generated.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or blank space for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { generalTempThresholdsEntry 6 }
|
|
--
|
|
-- 4.3.2.1.1.4
|
|
-- generalTempThresholdEntryWarningResetValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Temperature in degrees centigrade(C).
|
|
-- If the temperature rises above this value and
|
|
-- if a warning alert/event had previously been
|
|
-- created then the alert/event will be reset.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or blank space for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { generalTempThresholdsEntry 7 }
|
|
--
|
|
--
|
|
|
|
-- ********************************************************************************
|
|
-- Voltage Thresholds
|
|
-- ********************************************************************************
|
|
-- 4.3.2.2
|
|
voltageThresholds OBJECT IDENTIFIER ::= { monitorThresholds 2 }
|
|
|
|
voltageThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VoltageThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of voltage threshold entries.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
::= { voltageThresholds 1 }
|
|
|
|
voltageThresholdsEntry OBJECT-TYPE
|
|
SYNTAX VoltageThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold entries.
|
|
|
|
NOTE: This MIB is for Blade Center Enterprise only."
|
|
INDEX { voltageThresholdEntryIndex }
|
|
::= { voltageThresholdsTable 1 }
|
|
|
|
VoltageThresholdsEntry ::= SEQUENCE {
|
|
voltageThresholdEntryIndex INTEGER(0..255),
|
|
voltageThresholdEntryName OCTET STRING (SIZE(0..16)),
|
|
voltageThresholdEntryCurrentValue OCTET STRING,
|
|
-- voltageThresholdEntryHardShutdownHighValue OCTET STRING,
|
|
-- voltageThresholdEntrySoftShutdownHighValue OCTET STRING,
|
|
voltageThresholdEntryWarningHighValue OCTET STRING,
|
|
voltageThresholdEntryWarningResetHighValue OCTET STRING,
|
|
-- voltageThresholdEntryHardShutdownLowValue OCTET STRING,
|
|
-- voltageThresholdEntrySoftShutdownLowValue OCTET STRING,
|
|
voltageThresholdEntryWarningLowValue OCTET STRING,
|
|
voltageThresholdEntryWarningResetLowValue OCTET STRING
|
|
}
|
|
|
|
|
|
voltageThresholdEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for voltage threshold entry."
|
|
|
|
::= { voltageThresholdsEntry 1 }
|
|
|
|
-- 4.3.2.2.x
|
|
voltageThresholdEntryName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold entry null terminated string that
|
|
contains the power supply's name, for example '+5V'."
|
|
|
|
::= { voltageThresholdsEntry 2 }
|
|
|
|
-- 2.1.2.x
|
|
voltageThresholdEntryCurrentValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 3 }
|
|
|
|
-- 4.3.2.2.x.1
|
|
-- voltageThresholdEntryHardShutdownHighValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Voltage threshold reading expressed in Volts(V).
|
|
-- If the voltage rises above this value the
|
|
-- system will be powered off immediately.
|
|
-- If enabled, a critical alert/event will be generated.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { voltageThresholdsEntry 4 }
|
|
--
|
|
-- 4.3.2.2.x.2
|
|
-- voltageThresholdEntrySoftShutdownHighValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Voltage threshold reading expressed in Volts(V).
|
|
-- If the voltage rises above this value, the system will
|
|
-- be powered off after the O/S is shut down.
|
|
-- If enabled, a critical alert/event is generated.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { voltageThresholdsEntry 5 }
|
|
|
|
-- 4.3.2.2.x.3
|
|
voltageThresholdEntryWarningHighValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value, a warning
|
|
alert/event, if enabled, will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 6 }
|
|
|
|
-- 4.3.2.2.x.4
|
|
voltageThresholdEntryWarningResetHighValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value and
|
|
if a warning alert/event had previously been
|
|
created, then the alert/event will be reset.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 7 }
|
|
|
|
-- 4.3.2.2.x.5
|
|
-- voltageThresholdEntryHardShutdownLowValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Voltage threshold reading expressed in Volts(V).
|
|
-- If the voltage drops below this value, the
|
|
-- system will be powered off immediately.
|
|
-- If enabled, a critical alert/event will be generated.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { voltageThresholdsEntry 8 }
|
|
--
|
|
-- 4.3.2.2.x.6
|
|
-- voltageThresholdEntrySoftShutdownLowValue OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Voltage threshold reading expressed in Volts(V).
|
|
-- If the voltage drops below this value, the system will
|
|
-- be powered off after the O/S is shut down.
|
|
-- If enabled, a critical alert/event is generated.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { voltageThresholdsEntry 9 }
|
|
|
|
-- 4.3.2.2.x.7
|
|
voltageThresholdEntryWarningLowValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value, a warning
|
|
alert/event, if enabled, will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 10 }
|
|
|
|
-- 4.3.2.2.x.8
|
|
voltageThresholdEntryWarningResetLowValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value and
|
|
if a warning alert/event had previously been
|
|
created, then the alert/event will be reset.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 11 }
|
|
|
|
-- ********************************************************************************
|
|
-- Vital Product Data(VPD) information
|
|
-- ********************************************************************************
|
|
-- 4.3.5
|
|
vpdInformation OBJECT IDENTIFIER ::= { monitors 21 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Firmware Level VPD
|
|
-- ********************************************************************************
|
|
-- the following has been removed until it is supported
|
|
-- bios vpd was the only section not already commented out
|
|
-- systemFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 1 }
|
|
--
|
|
-- ********************************************************************************
|
|
-- BIOS Firmware Level VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.1
|
|
--
|
|
-- biosVpd OBJECT IDENTIFIER ::= { systemFirmwareVpd 1 }
|
|
--
|
|
-- biosVpdVersionNumber OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Bios firmware version number (from System BIOS)."
|
|
-- ::= { biosVpd 1 }
|
|
--
|
|
-- biosVpdBuildLevelName OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Bios firmware build level name (from System BIOS)."
|
|
-- ::= { biosVpd 2 }
|
|
--
|
|
-- biosVpdBuildDate OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Bios firmware build date (from System BIOS)."
|
|
-- ::= { biosVpd 3 }
|
|
--
|
|
--
|
|
-- ********************************************************************************
|
|
-- DIAG Firmware Level VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.1.1
|
|
-- diagVpd OBJECT IDENTIFIER ::= { systemFirmwareVpd 2 }
|
|
--
|
|
-- diagVpdVersionNumber OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Diagnostics firmware version number (from System BIOS)."
|
|
-- ::= { diagVpd 1 }
|
|
--
|
|
-- diagVpdBuildLevelName OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Diagnostics firmware build level name (from System BIOS)."
|
|
-- ::= { diagVpd 2 }
|
|
--
|
|
-- diagVpdBuildDate OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Diagnostics firmware build date (from System BIOS)."
|
|
-- ::= { diagVpd 3 }
|
|
--
|
|
--
|
|
-- ********************************************************************************
|
|
-- Power backplane firmware VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.13.1
|
|
-- powerBackplaneFirmwareVpd OBJECT IDENTIFIER ::= { systemFirmwareVpd 15 }
|
|
--
|
|
-- 15.1.1
|
|
-- powerBackplaneRevisionNumber OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Power Backplane firmware revison number."
|
|
-- ::= { powerBackplaneFirmwareVpd 1 }
|
|
--
|
|
--
|
|
-- ********************************************************************************
|
|
-- Integrated system management processor VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.6?? 4.3.5.19 doesn't exist
|
|
-- ismpFirmwareVpd OBJECT IDENTIFIER ::= { systemFirmwareVpd 19 }
|
|
--
|
|
-- 19.1.1
|
|
-- ismpRevisionNumber OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "ISMP firmware revison number."
|
|
-- ::= { ismpFirmwareVpd 1 }
|
|
--
|
|
--
|
|
-- ********************************************************************************
|
|
-- Machine Level VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.2.1
|
|
chassisVpd OBJECT IDENTIFIER ::= { vpdInformation 1 }
|
|
|
|
|
|
bladeCenterVpd OBJECT IDENTIFIER ::= { chassisVpd 1 }
|
|
|
|
-- 4.3.5.2.1
|
|
bladeCenterVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine type VPD information (from System BIOS)."
|
|
::= { bladeCenterVpd 1 }
|
|
|
|
-- 4.3.5.2.1
|
|
bladeCenterVpdMachineModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine model VPD information (from System BIOS)."
|
|
::= { bladeCenterVpd 2 }
|
|
|
|
-- 4.3.5.2.1
|
|
bladeCenterSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine serial number VPD information (from System BIOS)."
|
|
::= { bladeCenterVpd 3 }
|
|
|
|
-- 4.3.5.2.1
|
|
bladeCenterUUID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine UUID (Universal Unique ID information) (from System BIOS)."
|
|
::= { bladeCenterVpd 4 }
|
|
|
|
bladeCenterManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis manufacturing ID."
|
|
::= { bladeCenterVpd 5 }
|
|
|
|
bladeCenterHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis hardware revision."
|
|
::= { bladeCenterVpd 6 }
|
|
|
|
bladeCenterFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis FRU number."
|
|
::= { bladeCenterVpd 7 }
|
|
|
|
bladeCenterManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis manufature date."
|
|
::= { bladeCenterVpd 8 }
|
|
|
|
bladeCenterPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis part number."
|
|
::= { bladeCenterVpd 9 }
|
|
|
|
bladeCenterFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis FRU serial."
|
|
::= { bladeCenterVpd 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Management Module Hardware VPD
|
|
-- ********************************************************************************
|
|
mmHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 2 }
|
|
|
|
mmHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the management module hardware components.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { mmHardwareVpd 1 }
|
|
|
|
mmHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX MmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD entry.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
INDEX { mmHardwareVpdIndex }
|
|
::= { mmHardwareVpdTable 1 }
|
|
|
|
MmHardwareVpdEntry ::= SEQUENCE {
|
|
mmHardwareVpdIndex INTEGER,
|
|
mmHardwareVpdBayNumber OCTET STRING,
|
|
mmHardwareVpdManufacturingId OCTET STRING,
|
|
mmHardwareVpdFruNumber OCTET STRING,
|
|
mmHardwareVpdHardwareRevision INTEGER,
|
|
mmHardwareVpdUuid OCTET STRING,
|
|
mmHardwareVpdManufDate OCTET STRING,
|
|
mmHardwareVpdPartNumber OCTET STRING,
|
|
mmHardwareVpdFruSerial OCTET STRING
|
|
}
|
|
|
|
mmHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD index.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 1 }
|
|
|
|
mmHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD Bay number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 2 }
|
|
|
|
mmHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 3 }
|
|
|
|
mmHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD FRU number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 4 }
|
|
|
|
mmHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD hardware revision.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 5 }
|
|
|
|
|
|
mmHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD UUID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 6 }
|
|
|
|
mmHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD manufacture date.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 7 }
|
|
|
|
mmHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD Part number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 8 }
|
|
|
|
mmHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD FRU serial.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mmHardwareVpdEntry 9 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- System Firmware Level VPD
|
|
-- ********************************************************************************
|
|
mmFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- SP Firmware VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.6.1
|
|
mmMainApplVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmMainApplVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SP Firmware VPD."
|
|
::= { mmFirmwareVpd 1 }
|
|
|
|
mmMainApplVpdEntry OBJECT-TYPE
|
|
SYNTAX MmMainApplVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Firmware VPD entry."
|
|
INDEX { mmMainApplVpdIndex }
|
|
::= { mmMainApplVpdTable 1 }
|
|
|
|
|
|
MmMainApplVpdEntry ::= SEQUENCE {
|
|
mmMainApplVpdIndex INTEGER,
|
|
mmMainApplVpdName OCTET STRING,
|
|
mmMainApplVpdBuildId OCTET STRING,
|
|
mmMainApplVpdRevisonNumber OCTET STRING,
|
|
mmMainApplVpdFilename OCTET STRING,
|
|
mmMainApplVpdBuildDate OCTET STRING
|
|
}
|
|
|
|
|
|
mmMainApplVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD index."
|
|
::= { mmMainApplVpdEntry 1 }
|
|
|
|
mmMainApplVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD name description."
|
|
::= { mmMainApplVpdEntry 2 }
|
|
|
|
mmMainApplVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build identification."
|
|
::= { mmMainApplVpdEntry 3 }
|
|
|
|
mmMainApplVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD revision number."
|
|
::= { mmMainApplVpdEntry 4 }
|
|
|
|
mmMainApplVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD file name."
|
|
::= { mmMainApplVpdEntry 5 }
|
|
|
|
mmMainApplVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build date."
|
|
::= { mmMainApplVpdEntry 6 }
|
|
|
|
-- ********************************************************************************
|
|
-- SP Firmware VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.6.2
|
|
mmBootROMVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmBootROMVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SP Firmware VPD."
|
|
::= { mmFirmwareVpd 2 }
|
|
|
|
mmBootROMVpdEntry OBJECT-TYPE
|
|
SYNTAX MmBootROMVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Firmware VPD entry."
|
|
INDEX { mmBootROMVpdIndex }
|
|
::= { mmBootROMVpdTable 1 }
|
|
|
|
|
|
MmBootROMVpdEntry ::= SEQUENCE {
|
|
mmBootROMVpdIndex INTEGER,
|
|
mmBootROMVpdName OCTET STRING,
|
|
mmBootROMVpdBuildId OCTET STRING,
|
|
mmBootROMVpdRevisonNumber OCTET STRING,
|
|
mmBootROMVpdFilename OCTET STRING,
|
|
mmBootROMVpdBuildDate OCTET STRING
|
|
}
|
|
|
|
|
|
mmBootROMVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD index."
|
|
::= { mmBootROMVpdEntry 1 }
|
|
|
|
mmBootROMVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD name description."
|
|
::= { mmBootROMVpdEntry 2 }
|
|
|
|
mmBootROMVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build identification."
|
|
::= { mmBootROMVpdEntry 3 }
|
|
|
|
mmBootROMVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD revision number."
|
|
::= { mmBootROMVpdEntry 4 }
|
|
|
|
mmBootROMVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD file name."
|
|
::= { mmBootROMVpdEntry 5 }
|
|
|
|
mmBootROMVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build date."
|
|
::= { mmBootROMVpdEntry 6 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SP Firmware VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.6.3
|
|
mmRemoteControlVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmRemoteControlVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SP Firmware VPD."
|
|
::= { mmFirmwareVpd 3 }
|
|
|
|
mmRemoteControlVpdEntry OBJECT-TYPE
|
|
SYNTAX MmRemoteControlVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Firmware VPD entry."
|
|
INDEX { mmRemoteControlVpdIndex }
|
|
::= { mmRemoteControlVpdTable 1 }
|
|
|
|
|
|
MmRemoteControlVpdEntry ::= SEQUENCE {
|
|
mmRemoteControlVpdIndex INTEGER,
|
|
mmRemoteControlVpdName OCTET STRING,
|
|
mmRemoteControlVpdBuildId OCTET STRING,
|
|
mmRemoteControlVpdRevisonNumber OCTET STRING,
|
|
mmRemoteControlVpdFilename OCTET STRING,
|
|
mmRemoteControlVpdBuildDate OCTET STRING
|
|
}
|
|
|
|
|
|
mmRemoteControlVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD index."
|
|
::= { mmRemoteControlVpdEntry 1 }
|
|
|
|
mmRemoteControlVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD name description."
|
|
::= { mmRemoteControlVpdEntry 2 }
|
|
|
|
mmRemoteControlVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build identification."
|
|
::= { mmRemoteControlVpdEntry 3 }
|
|
|
|
mmRemoteControlVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD revision number."
|
|
::= { mmRemoteControlVpdEntry 4 }
|
|
|
|
mmRemoteControlVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD file name."
|
|
::= { mmRemoteControlVpdEntry 5 }
|
|
|
|
mmRemoteControlVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build date."
|
|
::= { mmRemoteControlVpdEntry 6 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SP Firmware VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.20.1
|
|
mmPS2toUSBConvVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmPS2toUSBConvVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SP Firmware VPD."
|
|
::= { mmFirmwareVpd 4 }
|
|
|
|
mmPS2toUSBConvVpdEntry OBJECT-TYPE
|
|
SYNTAX MmPS2toUSBConvVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Firmware VPD entry."
|
|
INDEX { mmPS2toUSBConvVpdIndex }
|
|
::= { mmPS2toUSBConvVpdTable 1 }
|
|
|
|
|
|
MmPS2toUSBConvVpdEntry ::= SEQUENCE {
|
|
mmPS2toUSBConvVpdIndex INTEGER,
|
|
mmPS2toUSBConvVpdName OCTET STRING,
|
|
mmPS2toUSBConvVpdBuildId OCTET STRING,
|
|
mmPS2toUSBConvVpdRevisonNumber OCTET STRING,
|
|
mmPS2toUSBConvVpdFilename OCTET STRING,
|
|
mmPS2toUSBConvVpdBuildDate OCTET STRING
|
|
}
|
|
|
|
|
|
mmPS2toUSBConvVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD index."
|
|
::= { mmPS2toUSBConvVpdEntry 1 }
|
|
|
|
mmPS2toUSBConvVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD name description."
|
|
::= { mmPS2toUSBConvVpdEntry 2 }
|
|
|
|
mmPS2toUSBConvVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build identification."
|
|
::= { mmPS2toUSBConvVpdEntry 3 }
|
|
|
|
mmPS2toUSBConvVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD revision number."
|
|
::= { mmPS2toUSBConvVpdEntry 4 }
|
|
|
|
mmPS2toUSBConvVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD file name."
|
|
::= { mmPS2toUSBConvVpdEntry 5 }
|
|
|
|
mmPS2toUSBConvVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build date."
|
|
::= { mmPS2toUSBConvVpdEntry 6 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SP Firmware VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.20.2
|
|
mmToUSBIntfVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmToUSBIntfVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SP Firmware VPD."
|
|
::= { mmFirmwareVpd 5 }
|
|
|
|
mmToUSBIntfVpdEntry OBJECT-TYPE
|
|
SYNTAX MmToUSBIntfVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Firmware VPD entry."
|
|
INDEX { mmToUSBIntfVpdIndex }
|
|
::= { mmToUSBIntfVpdTable 1 }
|
|
|
|
|
|
MmToUSBIntfVpdEntry ::= SEQUENCE {
|
|
mmToUSBIntfVpdIndex INTEGER,
|
|
mmToUSBIntfVpdName OCTET STRING,
|
|
mmToUSBIntfVpdBuildId OCTET STRING,
|
|
mmToUSBIntfVpdRevisonNumber OCTET STRING,
|
|
mmToUSBIntfVpdFilename OCTET STRING,
|
|
mmToUSBIntfVpdBuildDate OCTET STRING
|
|
}
|
|
|
|
|
|
mmToUSBIntfVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD index."
|
|
::= { mmToUSBIntfVpdEntry 1 }
|
|
|
|
mmToUSBIntfVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD name description."
|
|
::= { mmToUSBIntfVpdEntry 2 }
|
|
|
|
mmToUSBIntfVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build identification."
|
|
::= { mmToUSBIntfVpdEntry 3 }
|
|
|
|
mmToUSBIntfVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD revision number."
|
|
::= { mmToUSBIntfVpdEntry 4 }
|
|
|
|
mmToUSBIntfVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD file name."
|
|
::= { mmToUSBIntfVpdEntry 5 }
|
|
|
|
mmToUSBIntfVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build date."
|
|
::= { mmToUSBIntfVpdEntry 6 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Inventory Management VPD
|
|
-- ********************************************************************************
|
|
-- 4.3.5.21
|
|
inventoryManagementVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InventoryManagementVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the hardware components, (modules or blades)
|
|
for which the system provides VPD information.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { vpdInformation 21 }
|
|
|
|
inventoryManagementVpdEntry OBJECT-TYPE
|
|
SYNTAX InventoryManagementVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component hardware VPD entry.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
INDEX { componentLevelVpdIndex }
|
|
::= { inventoryManagementVpdTable 1 }
|
|
|
|
InventoryManagementVpdEntry ::= SEQUENCE {
|
|
componentLevelVpdIndex INTEGER,
|
|
componentLevelVpdFruNumber OCTET STRING,
|
|
componentLevelVpdSerialNumber OCTET STRING,
|
|
componentLevelVpdManufacturingId OCTET STRING,
|
|
componentLevelVpdBayNumber OCTET STRING,
|
|
componentLevelVpdTypeCode INTEGER,
|
|
componentLevelVpdMachineType OCTET STRING,
|
|
componentLevelVpdHardwareRevision INTEGER
|
|
}
|
|
|
|
componentLevelVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD index.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementVpdEntry 1 }
|
|
|
|
componentLevelVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD FRU number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementVpdEntry 2 }
|
|
|
|
componentLevelVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD serial number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementVpdEntry 3 }
|
|
|
|
componentLevelVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD manufacturing ID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementVpdEntry 4 }
|
|
|
|
componentLevelVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD Bay number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementVpdEntry 5 }
|
|
|
|
componentLevelVpdTypeCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
bladeX86OneWay(1),
|
|
bladeX86TwoWay(2),
|
|
bladeX86FourWay(4),
|
|
switchModuleEthernet(17),
|
|
switchModuleFiberChannel(18),
|
|
scalabilityPortModule(19),
|
|
switchModuleInfiniband(20),
|
|
switchModuleMixedProtocol(21),
|
|
switchModuleCopperPassThrough(40),
|
|
bladeEthernetDaughterCard(33),
|
|
bladeFiberChannelDaughterCard(34),
|
|
bladeStorageExpansionUnit(35),
|
|
serialPortExpansionCard(47),
|
|
managementModule(81),
|
|
chassis(97),
|
|
powerModule(113),
|
|
mediaTray(129)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD Type Code.
|
|
Describes what the blade or module is.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementVpdEntry 6 }
|
|
|
|
componentLevelVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD machine type.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementVpdEntry 7 }
|
|
|
|
componentLevelVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD hardware revision.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementVpdEntry 8 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Component Level VPD Activity log
|
|
-- ********************************************************************************
|
|
-- 4.3.5.22
|
|
inventoryManagementActivityVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InventoryManagementActivityVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of system component hardware VPD activity log.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { vpdInformation 22 }
|
|
|
|
inventoryManagementActivityVpdEntry OBJECT-TYPE
|
|
SYNTAX InventoryManagementActivityVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component hardware VPD activity log entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { componentLevelActivityVpdIndex }
|
|
::= { inventoryManagementActivityVpdTable 1 }
|
|
|
|
InventoryManagementActivityVpdEntry ::= SEQUENCE {
|
|
componentLevelActivityVpdIndex INTEGER,
|
|
componentLevelActivityVpdFruNumber OCTET STRING,
|
|
componentLevelActivityVpdSerialNumber OCTET STRING,
|
|
componentLevelActivityVpdManufacturingId OCTET STRING,
|
|
componentLevelActivityVpdBayNumber OCTET STRING,
|
|
-- componentLevelActivityVpdTypeCode INTEGER,
|
|
-- componentLevelActivityVpdMachineType OCTET STRING,
|
|
-- componentLevelActivityVpdHardwareRevision INTEGER,
|
|
componentLevelActivityVpdAction OCTET STRING,
|
|
componentLevelActivityVpdTimestamp OCTET STRING
|
|
|
|
}
|
|
|
|
componentLevelActivityVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log index.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 1 }
|
|
|
|
componentLevelActivityVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 2 }
|
|
|
|
componentLevelActivityVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 3 }
|
|
|
|
componentLevelActivityVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 4 }
|
|
|
|
componentLevelActivityVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 5 }
|
|
|
|
-- componentLevelActivityVpdTypeCode OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- unknown(0),
|
|
-- bladeX86OneWay(1),
|
|
-- bladeX86TwoWay(2),
|
|
-- bladeX86FourWay(4),
|
|
-- switchModuleEthernet(17),
|
|
-- switchModuleFiberChannel(18),
|
|
-- scalabilityPortModule(19),
|
|
-- switchModuleInfiniband(20),
|
|
-- switchModuleMixedProtocol(21),
|
|
-- bladeEthernetDaughterCard(33),
|
|
-- bladeFiberChannelDaughterCard(34),
|
|
-- bladeStorageExpansionUnit(35),
|
|
-- serialPortExpansionCard(47),
|
|
-- managementModule(81),
|
|
-- chassis(97),
|
|
-- powerModule(113),
|
|
-- mediaTray(129)
|
|
-- }
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "System component level VPD Type Code.
|
|
-- Describes what the blade or module is.
|
|
-- For consistent results, view as a table and
|
|
-- not as individual entries."
|
|
-- ::= { inventoryManagementActivityVpdEntry 6 }
|
|
|
|
-- componentLevelActivityVpdMachineType OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "System component level VPD machine type.
|
|
-- For consistent results, view as a table and
|
|
-- not as individual entries."
|
|
-- ::= { inventoryManagementActivityVpdEntry 7 }
|
|
|
|
-- componentLevelActivityVpdHardwareRevision OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "System component level VPD activity hardware revision.
|
|
-- For consistent results, view as a table and
|
|
-- not as individual entries."
|
|
-- ::= { inventoryManagementActivityVpdEntry 8 }
|
|
|
|
componentLevelActivityVpdAction OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log action (added/removed).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= {inventoryManagementActivityVpdEntry 9 }
|
|
|
|
componentLevelActivityVpdTimestamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log timestamp.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade Hardware VPD
|
|
-- ********************************************************************************
|
|
bladeHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 4 }
|
|
|
|
bladeHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of VPD information for the blade server
|
|
hardware components.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { bladeHardwareVpd 1 }
|
|
|
|
bladeHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server hardware VPD entry.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
INDEX { bladeHardwareVpdIndex }
|
|
::= { bladeHardwareVpdTable 1 }
|
|
|
|
BladeHardwareVpdEntry ::= SEQUENCE {
|
|
bladeHardwareVpdIndex INTEGER,
|
|
bladeHardwareVpdBayNumber OCTET STRING,
|
|
bladeHardwareVpdManufacturingId OCTET STRING,
|
|
bladeHardwareVpdFruNumber OCTET STRING,
|
|
bladeHardwareVpdHardwareRevision INTEGER,
|
|
bladeHardwareVpdSerialNumber OCTET STRING,
|
|
bladeHardwareVpdMachineType OCTET STRING,
|
|
bladeHardwareVpdUuid OCTET STRING,
|
|
bladeHardwareVpdManufDate OCTET STRING,
|
|
bladeHardwareVpdPartNumber OCTET STRING,
|
|
bladeHardwareVpdFruSerial OCTET STRING,
|
|
bladeDaughterVpdCardType INTEGER,
|
|
bladeDaughterVpdManufacturingId OCTET STRING,
|
|
bladeDaughterVpdFruNumber OCTET STRING,
|
|
bladeDaughterVpdHardwareRevision INTEGER,
|
|
bladeDaughterVpdSerialNumber OCTET STRING,
|
|
bladeDaughterVpdMachineType OCTET STRING,
|
|
bladeDaughterVpdUuid OCTET STRING,
|
|
bladeDaughterVpdManufDate OCTET STRING,
|
|
bladeDaughterVpdPartNumber OCTET STRING,
|
|
bladeDaughterVpdFruSerial OCTET STRING
|
|
}
|
|
|
|
bladeHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD index.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 1 }
|
|
|
|
bladeHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD Bay number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 2 }
|
|
|
|
bladeHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 3 }
|
|
|
|
bladeHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD FRU number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 4 }
|
|
|
|
bladeHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD hardware revision.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 5 }
|
|
|
|
bladeHardwareVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD serial number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 6 }
|
|
|
|
bladeHardwareVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD machine type.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 7 }
|
|
|
|
bladeHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD UUID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 8 }
|
|
|
|
bladeHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD Manufature Date.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 9 }
|
|
|
|
bladeHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD Part number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 10 }
|
|
|
|
bladeHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD FRU serial.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 11 }
|
|
|
|
bladeDaughterVpdCardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
network(1),
|
|
dasd(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter card VPD Type Code.
|
|
Describes what the blade or module is.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 20 }
|
|
|
|
bladeDaughterVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter card VPD manufacturing ID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 21 }
|
|
|
|
bladeDaughterVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter card VPD FRU number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 22 }
|
|
|
|
bladeDaughterVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter card VPD hardware revision.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 23 }
|
|
|
|
bladeDaughterVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter card VPD Serial number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 24 }
|
|
|
|
bladeDaughterVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter card VPD Machine type.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 25 }
|
|
|
|
bladeDaughterVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter VPD UUID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 26 }
|
|
|
|
bladeDaughterVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter VPD Manufacture date.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 27 }
|
|
|
|
bladeDaughterVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter VPD Part number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 28 }
|
|
|
|
bladeDaughterVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade daughter VPD FRU Serial.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeHardwareVpdEntry 29 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Blade MAC Address VPD
|
|
-- ********************************************************************************
|
|
|
|
bladeMACAddressVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeMACAddressVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of MAC addresses of the blade server and its daughter cards.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpd 2 }
|
|
|
|
bladeMACAddressVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeMACAddressVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server MAC address entry. For consistent results, view as a
|
|
table and not as individual entries."
|
|
INDEX { bladeMACAddressVpdIndex }
|
|
::= { bladeMACAddressVpdTable 1 }
|
|
|
|
|
|
BladeMACAddressVpdEntry ::= SEQUENCE {
|
|
bladeMACAddressVpdIndex INTEGER,
|
|
bladeMACAddress1Vpd OCTET STRING,
|
|
bladeMACAddress2Vpd OCTET STRING,
|
|
bladeMACAddress3Vpd OCTET STRING,
|
|
bladeMACAddress4Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress1Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress2Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress3Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress4Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress1Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress2Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress3Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress4Vpd OCTET STRING
|
|
}
|
|
|
|
bladeMACAddressVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server index. For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 1 }
|
|
|
|
bladeMACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server MAC address 1. For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 2 }
|
|
|
|
bladeMACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server MAC address 2. For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 3 }
|
|
|
|
bladeMACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server MAC address 3. For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 4 }
|
|
|
|
bladeMACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server MAC address 4. For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 5 }
|
|
|
|
bladeDaughterCard1MACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server Daughter Card 1 MAC address 1. For consistent results, view
|
|
as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 10 }
|
|
|
|
bladeDaughterCard1MACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server Daughter Card 1 MAC address 2. For consistent results, view
|
|
as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 11 }
|
|
|
|
bladeDaughterCard1MACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server daughter card 1 MAC address 3. For consistent results, view
|
|
as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 12 }
|
|
|
|
bladeDaughterCard1MACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server daughter card 1 MAC address 4. For consistent results, view
|
|
as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 13 }
|
|
|
|
bladeDaughterCard2MACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server daughter card 2 MAC address 1. For consistent results, view
|
|
as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 18 }
|
|
|
|
bladeDaughterCard2MACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server daughter card 2 MAC address 2. For consistent results, view
|
|
as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 19 }
|
|
|
|
bladeDaughterCard2MACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server daughter card 2 MAC address 3. For consistent results, view
|
|
as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 20 }
|
|
|
|
bladeDaughterCard2MACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade server daughter card 2 MAC address 4. For consistent results, view
|
|
as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 21 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- System Firmware Level VPD
|
|
-- ********************************************************************************
|
|
bladeFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 5 }
|
|
|
|
|
|
bladeBiosVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeBiosVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade firmware vital product data (VPD) information."
|
|
::= { bladeFirmwareVpd 1 }
|
|
|
|
bladeBiosVPDEntry OBJECT-TYPE
|
|
SYNTAX BladeBiosVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table entry"
|
|
INDEX { bladeBiosVpdIndex }
|
|
::= { bladeBiosVPDTable 1 }
|
|
|
|
|
|
BladeBiosVPDEntry ::= SEQUENCE {
|
|
bladeBiosVpdIndex INTEGER,
|
|
bladeBiosVpdId INTEGER,
|
|
bladeBiosVpdExists INTEGER,
|
|
bladeBiosVpdPowerState INTEGER,
|
|
bladeBiosVpdName OCTET STRING,
|
|
bladeBiosVpdBuildId OCTET STRING,
|
|
bladeBiosVpdRevision OCTET STRING,
|
|
bladeBiosVpdDate OCTET STRING
|
|
}
|
|
|
|
bladeBiosVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table index."
|
|
::= { bladeBiosVPDEntry 1 }
|
|
|
|
|
|
bladeBiosVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeBiosVPDEntry 2 }
|
|
|
|
bladeBiosVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeBiosVPDEntry 3 }
|
|
|
|
bladeBiosVpdPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeBiosVPDEntry 4 }
|
|
|
|
bladeBiosVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeBiosVPDEntry 5 }
|
|
|
|
bladeBiosVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The build ID for the blade firmware."
|
|
::= { bladeBiosVPDEntry 6 }
|
|
|
|
bladeBiosVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the blade firmware."
|
|
::= { bladeBiosVPDEntry 7 }
|
|
|
|
bladeBiosVpdDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the blade firmware."
|
|
::= { bladeBiosVPDEntry 8 }
|
|
|
|
|
|
|
|
bladeDiagsVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeDiagsVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade firmware vital product data (VPD) information."
|
|
::= { bladeFirmwareVpd 2 }
|
|
|
|
bladeDiagsVPDEntry OBJECT-TYPE
|
|
SYNTAX BladeDiagsVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table entry"
|
|
INDEX { bladeDiagsVpdIndex }
|
|
::= { bladeDiagsVPDTable 1 }
|
|
|
|
|
|
BladeDiagsVPDEntry ::= SEQUENCE {
|
|
bladeDiagsVpdIndex INTEGER,
|
|
bladeDiagsVpdId INTEGER,
|
|
bladeDiagsVpdExists INTEGER,
|
|
bladeDiagsVpdPowerState INTEGER,
|
|
bladeDiagsVpdName OCTET STRING,
|
|
bladeDiagsVpdBuildId OCTET STRING,
|
|
bladeDiagsVpdRevision OCTET STRING,
|
|
bladeDiagsVpdDate OCTET STRING
|
|
}
|
|
|
|
bladeDiagsVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table index."
|
|
::= { bladeDiagsVPDEntry 1 }
|
|
|
|
|
|
bladeDiagsVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeDiagsVPDEntry 2 }
|
|
|
|
bladeDiagsVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeDiagsVPDEntry 3 }
|
|
|
|
bladeDiagsVpdPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeDiagsVPDEntry 4 }
|
|
|
|
bladeDiagsVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeDiagsVPDEntry 5 }
|
|
|
|
bladeDiagsVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The build ID for the blade firmware."
|
|
::= { bladeDiagsVPDEntry 6 }
|
|
|
|
bladeDiagsVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the blade firmware."
|
|
::= { bladeDiagsVPDEntry 7 }
|
|
|
|
bladeDiagsVpdDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the blade firmware."
|
|
::= { bladeDiagsVPDEntry 8 }
|
|
|
|
|
|
|
|
|
|
bladeSysMgmtProcVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeSysMgmtProcVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade firmware vital product data (VPD) information."
|
|
::= { bladeFirmwareVpd 3 }
|
|
|
|
bladeSysMgmtProcVPDEntry OBJECT-TYPE
|
|
SYNTAX BladeSysMgmtProcVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table entry"
|
|
INDEX { bladeSysMgmtProcVpdIndex }
|
|
::= { bladeSysMgmtProcVPDTable 1 }
|
|
|
|
|
|
BladeSysMgmtProcVPDEntry ::= SEQUENCE {
|
|
bladeSysMgmtProcVpdIndex INTEGER,
|
|
bladeSysMgmtProcVpdId INTEGER,
|
|
bladeSysMgmtProcVpdExists INTEGER,
|
|
bladeSysMgmtProcVpdPowerState INTEGER,
|
|
bladeSysMgmtProcVpdName OCTET STRING,
|
|
bladeSysMgmtProcVpdBuildId OCTET STRING,
|
|
bladeSysMgmtProcVpdRevision OCTET STRING
|
|
}
|
|
|
|
bladeSysMgmtProcVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table index."
|
|
::= { bladeSysMgmtProcVPDEntry 1 }
|
|
|
|
|
|
bladeSysMgmtProcVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeSysMgmtProcVPDEntry 2 }
|
|
|
|
bladeSysMgmtProcVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeSysMgmtProcVPDEntry 3 }
|
|
|
|
bladeSysMgmtProcVpdPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeSysMgmtProcVPDEntry 4 }
|
|
|
|
bladeSysMgmtProcVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeSysMgmtProcVPDEntry 5 }
|
|
|
|
bladeSysMgmtProcVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The build ID for the blade firmware."
|
|
::= { bladeSysMgmtProcVPDEntry 6 }
|
|
|
|
bladeSysMgmtProcVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the blade firmware."
|
|
::= { bladeSysMgmtProcVPDEntry 7 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Switch Module Hardware VPD
|
|
-- ********************************************************************************
|
|
smHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 6 }
|
|
|
|
smHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the switch module hardware components.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { smHardwareVpd 1 }
|
|
|
|
smHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX SmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD entry.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
INDEX { smHardwareVpdIndex }
|
|
::= { smHardwareVpdTable 1 }
|
|
|
|
SmHardwareVpdEntry ::= SEQUENCE {
|
|
smHardwareVpdIndex INTEGER,
|
|
smHardwareVpdBayNumber OCTET STRING,
|
|
smHardwareVpdManufacturingId OCTET STRING,
|
|
smHardwareVpdFruNumber OCTET STRING,
|
|
smHardwareVpdHardwareRevision INTEGER,
|
|
smHardwareVpdUuid OCTET STRING,
|
|
smHardwareVpdManufDate OCTET STRING,
|
|
smHardwareVpdPartNumber OCTET STRING,
|
|
smHardwareVpdFruSerial OCTET STRING
|
|
}
|
|
|
|
smHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD index.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 1 }
|
|
|
|
smHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD Bay number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 2 }
|
|
|
|
smHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 3 }
|
|
|
|
smHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD FRU number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 4 }
|
|
|
|
smHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD hardware revision.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 5 }
|
|
|
|
smHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD UUID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 8 }
|
|
|
|
smHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD manufacture Date.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 9 }
|
|
|
|
smHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD Part Number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 10 }
|
|
|
|
smHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD FRU Serial.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { smHardwareVpdEntry 11 }
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module Information
|
|
-- ********************************************************************************
|
|
|
|
-- 22.3.3
|
|
smFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 7 }
|
|
-- Server blade switch module information
|
|
|
|
-- 22.3.3.1
|
|
smMainAppVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmMainAppVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module main application VPD information table."
|
|
::= {smFirmwareVpd 1}
|
|
|
|
smMainAppVpdEntry OBJECT-TYPE
|
|
SYNTAX SmMainAppVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module main application VPD table entry"
|
|
INDEX { smMainAppVpdIndex }
|
|
::= { smMainAppVpdTable 1 }
|
|
|
|
SmMainAppVpdEntry ::= SEQUENCE {
|
|
smMainAppVpdIndex INTEGER,
|
|
smMainAppVpdId INTEGER,
|
|
smMainAppVpdExists INTEGER,
|
|
smMainAppVpdSwitchType INTEGER,
|
|
smMainApp1VpdRevisionNumber OCTET STRING,
|
|
smMainApp1VpdBuildId OCTET STRING,
|
|
smMainApp1VpdBuildDate OCTET STRING,
|
|
smMainApp2VpdRevisionNumber OCTET STRING,
|
|
smMainApp2VpdBuildId OCTET STRING,
|
|
smMainApp2VpdBuildDate OCTET STRING
|
|
}
|
|
|
|
smMainAppVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module main application VPD entry index."
|
|
::= { smMainAppVpdEntry 1 }
|
|
|
|
smMainAppVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smMainAppVpdEntry 2 }
|
|
|
|
smMainAppVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not."
|
|
::= { smMainAppVpdEntry 3 }
|
|
|
|
smMainAppVpdSwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
opm(3),
|
|
serialCM(4),
|
|
copperPassThrough(5),
|
|
infiniband(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of switch module installed."
|
|
::= { smMainAppVpdEntry 4 }
|
|
|
|
smMainApp1VpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build id."
|
|
::= { smMainAppVpdEntry 5 }
|
|
|
|
smMainApp1VpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build date."
|
|
::= { smMainAppVpdEntry 6 }
|
|
|
|
smMainApp1VpdRevisionNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware revision number."
|
|
::= { smMainAppVpdEntry 7 }
|
|
|
|
smMainApp2VpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build id."
|
|
::= { smMainAppVpdEntry 8 }
|
|
|
|
smMainApp2VpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build date."
|
|
::= { smMainAppVpdEntry 9 }
|
|
|
|
smMainApp2VpdRevisionNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware revision number."
|
|
::= { smMainAppVpdEntry 10 }
|
|
|
|
|
|
|
|
|
|
|
|
smBootRomVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmBootRomVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module boot ROM VPD information table."
|
|
::= {smFirmwareVpd 2}
|
|
|
|
smBootRomVpdEntry OBJECT-TYPE
|
|
SYNTAX SmBootRomVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module boot ROM VPD table entry"
|
|
INDEX { smBootRomVpdIndex }
|
|
::= { smBootRomVpdTable 1 }
|
|
|
|
SmBootRomVpdEntry ::= SEQUENCE {
|
|
smBootRomVpdIndex INTEGER,
|
|
smBootRomVpdId INTEGER,
|
|
smBootRomVpdExists INTEGER,
|
|
smBootRomVpdSwitchType INTEGER,
|
|
smBootRomVpdRevisionNumber OCTET STRING,
|
|
smBootRomVpdBuildId OCTET STRING,
|
|
smBootRomVpdBuildDate OCTET STRING
|
|
}
|
|
|
|
smBootRomVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module boot ROM VPD entry index."
|
|
::= { smBootRomVpdEntry 1 }
|
|
|
|
smBootRomVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smBootRomVpdEntry 2 }
|
|
|
|
smBootRomVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not."
|
|
::= { smBootRomVpdEntry 3 }
|
|
|
|
smBootRomVpdSwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
opm(3),
|
|
serialCM(4),
|
|
copperPassThrough(5),
|
|
infiniband(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of switch module installed."
|
|
::= { smBootRomVpdEntry 4 }
|
|
|
|
smBootRomVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build ID."
|
|
::= { smBootRomVpdEntry 5 }
|
|
|
|
smBootRomVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build date."
|
|
::= { smBootRomVpdEntry 6 }
|
|
|
|
smBootRomVpdRevisionNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware revision number."
|
|
::= { smBootRomVpdEntry 7 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Power Module Hardware VPD
|
|
-- ********************************************************************************
|
|
pmHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 8 }
|
|
|
|
pmHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the power module hardware components.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { pmHardwareVpd 1 }
|
|
|
|
pmHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX PmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD entry.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
INDEX { pmHardwareVpdIndex }
|
|
::= { pmHardwareVpdTable 1 }
|
|
|
|
PmHardwareVpdEntry ::= SEQUENCE {
|
|
pmHardwareVpdIndex INTEGER,
|
|
pmHardwareVpdBayNumber OCTET STRING,
|
|
pmHardwareVpdManufacturingId OCTET STRING,
|
|
pmHardwareVpdFruNumber OCTET STRING,
|
|
pmHardwareVpdHardwareRevision INTEGER,
|
|
pmHardwareVpdUuid OCTET STRING,
|
|
pmHardwareVpdManufDate OCTET STRING,
|
|
pmHardwareVpdPartNumber OCTET STRING,
|
|
pmHardwareVpdFruSerial OCTET STRING
|
|
}
|
|
|
|
pmHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD index.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 1 }
|
|
|
|
pmHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD Bay number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 2 }
|
|
|
|
pmHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 3 }
|
|
|
|
pmHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD FRU number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 4 }
|
|
|
|
pmHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD hardware revision.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 5 }
|
|
|
|
pmHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD UUID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 8 }
|
|
|
|
pmHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD Manufacture Date.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 9 }
|
|
|
|
pmHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD PartNumber.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 10 }
|
|
|
|
pmHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD FRU Serial.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { pmHardwareVpdEntry 11 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Media Tray Hardware VPD
|
|
-- ********************************************************************************
|
|
mtHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 9 }
|
|
|
|
mtHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mtHardwareVpd 3 }
|
|
|
|
mtHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray hardware VPD FRU number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mtHardwareVpd 4 }
|
|
|
|
mtHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray hardware VPD hardware revision.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mtHardwareVpd 5 }
|
|
|
|
mtHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray hardware VPD UUID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { mtHardwareVpd 8 }
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SP Clock
|
|
-- ********************************************************************************
|
|
-- 4.4
|
|
spClock OBJECT IDENTIFIER ::= { configureSP 4 }
|
|
|
|
-- 4.4.1
|
|
spClockDateAndTimeSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"ASM clock date and time setting.
|
|
A date-time specification for the local time of day.
|
|
For example to set the date and time to
|
|
March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'.
|
|
field contents range
|
|
_____ ________ _____
|
|
1 month 01..12
|
|
2 separator '/'
|
|
3 day 01..31
|
|
4 separator '/'
|
|
5 year 2000..2089
|
|
6 separator ','
|
|
7 hour 00..23
|
|
8 separator ':'
|
|
9 minutes 00..59
|
|
10 separator ':'
|
|
11 seconds 00..59
|
|
"
|
|
::= { spClock 1 }
|
|
|
|
-- 4.4.2
|
|
spClockTimezoneSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"ASM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST)
|
|
settings.
|
|
|
|
The following table lists GMT offsets and associated DST
|
|
information. DST is not observed in time zones where
|
|
the 'Observe DST' value does not contain 'yes' in the table.
|
|
Also, note that in some cases additional information
|
|
is required to determine the clock adjustment when DST is
|
|
observed. The additional information is required when the
|
|
GMT offset being written is +2:00 or +10:00.
|
|
|
|
Examples
|
|
-to set the GMT offset to +3:30,
|
|
set the value to:'+3:30,no'
|
|
|
|
-for Eastern Standard Time and observing DST,
|
|
set the value to:'-5:00,yes'
|
|
|
|
-for Egypt and observing DST,
|
|
set the value to:'+2:00,yes,6'
|
|
|
|
|
|
GMT Observe Additional
|
|
Offset DST? DST value
|
|
______ _______ __________
|
|
+0:00 yes|no
|
|
+1:00 yes|no
|
|
+2:00 yes|no When 'Observe DST?' value is 'yes':
|
|
5 (for E.Europe)
|
|
4 (for GTB)
|
|
6 (for Egypt)
|
|
7 (for FLE)
|
|
+3:00 yes|no
|
|
+3:30 yes|no
|
|
+4:00 no
|
|
+4:30 no
|
|
+5:00 yes|no
|
|
+5:30 no
|
|
+6:00 no
|
|
+7:00 no
|
|
+8:00 no
|
|
+9:00 yes|no
|
|
+9:30 yes|no
|
|
+10:00 yes|no When 'Observe DST?' value is 'yes':
|
|
9 (for AUS Eastern)
|
|
10 (for Tasmania)
|
|
4 (for Vladivostok)
|
|
+11:00 no
|
|
+12:00 yes|no
|
|
-12:00 no
|
|
-11:00 no
|
|
-10:00 no
|
|
-9:00 yes|no
|
|
-8:00 yes|no
|
|
-7:00 yes|no
|
|
-6:00 yes|no
|
|
-5:00 yes|no
|
|
-4:00 yes|no
|
|
-3:30 yes|no
|
|
-3:00 yes|no
|
|
-2:00 yes|no
|
|
-1:00 yes|no
|
|
"
|
|
::= { spClock 2 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SP identification
|
|
-- ********************************************************************************
|
|
-- 4.5
|
|
spIdentification OBJECT IDENTIFIER ::= { configureSP 5 }
|
|
|
|
-- 4.5.1
|
|
spTxtId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"ASM text ID. Note: Do not put any 'space
|
|
characters' at end of the ID."
|
|
::= { spIdentification 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- Network Configuration
|
|
-- ********************************************************************************
|
|
-- 4.9
|
|
networkConfiguration OBJECT IDENTIFIER ::= { configureSP 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- Network Interfaces
|
|
-- ********************************************************************************
|
|
-- 4.9.1
|
|
networkInterfaces OBJECT IDENTIFIER ::= { networkConfiguration 1 }
|
|
-- ********************************************************************************
|
|
-- Ethernet Interface 1
|
|
-- ********************************************************************************
|
|
-- 4.9.1.1
|
|
extEthernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 1 }
|
|
|
|
-- 4.9.1.1.1
|
|
extEthernetInterfaceType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of interface. Indicates 'Ethernet-1'."
|
|
::= { extEthernetInterface 1 }
|
|
|
|
-- 4.9.1.1.3
|
|
extEthernetInterfaceHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated DNS host name for this
|
|
interface."
|
|
::= { extEthernetInterface 3 }
|
|
|
|
-- 4.9.1.1.4
|
|
extEthernetInterfaceIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address for the ethernet interface."
|
|
::= { extEthernetInterface 4 }
|
|
|
|
-- 4.9.1.1.5
|
|
extEthernetInterfaceDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enet10Megabit(3),
|
|
enet100Megabit(4),
|
|
autoSpeed(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the data transfer rate to be used over the ethernet
|
|
interface: 10Mb, 100Mb, or Auto."
|
|
::= { extEthernetInterface 5 }
|
|
|
|
-- 4.9.1.1.6
|
|
extEthernetInterfaceDuplexSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fullDuplex(1),
|
|
halfDuplex(2),
|
|
autoDuplex(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the duplex settings for the data transfer rate to be used over
|
|
the ethernet interface: Half, Full, or Auto."
|
|
::= { extEthernetInterface 6 }
|
|
|
|
-- 4.9.1.1.7
|
|
extEthernetInterfaceLAA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the locally administered MAC address. The locally administered
|
|
address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This
|
|
value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and
|
|
A - F. This ASM subsystem does not allow use of a multicast address. A multicast
|
|
address has the least significant bit of the first byte set to a 1. The first
|
|
byte must, therefore, be an even number."
|
|
::= { extEthernetInterface 7 }
|
|
|
|
-- 4.9.1.1.8
|
|
extEthernetInterfaceDhcpEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dhcpDisabled(0),
|
|
dhcpEnabled(1),
|
|
tryDhcpThenTryStatic(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable DHCP on this interface."
|
|
::= { extEthernetInterface 8 }
|
|
|
|
-- 4.9.1.1.9
|
|
extEthernetInterfaceGatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address of the gateway/router for the ethernet
|
|
interface."
|
|
::= { extEthernetInterface 9 }
|
|
|
|
-- 4.9.1.1.10
|
|
extEthernetInterfaceBIA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the burned-in MAC (BIA) address."
|
|
::= { extEthernetInterface 10 }
|
|
|
|
-- 4.9.1.1.13
|
|
extEthernetInterfaceMTU OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Maximum Transmission Unit(MTU) for the ethernet
|
|
interface"
|
|
::= { extEthernetInterface 13 }
|
|
|
|
-- 4.9.1.1.14
|
|
extEthernetInterfaceSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the subnet mask for the ethernet interface"
|
|
::= { extEthernetInterface 14 }
|
|
|
|
-- ********************************************************************************
|
|
-- DHCP Server Assigned Settings for ethernet interface 1
|
|
-- ********************************************************************************
|
|
|
|
-- 4.9.1.x.16
|
|
dhcpEthernetInterface OBJECT IDENTIFIER ::= { extEthernetInterface 16 }
|
|
|
|
-- 4.9.1.x.16.1
|
|
dhcpHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated DNS host name for this
|
|
interface, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 1 }
|
|
|
|
-- 4.9.1.x.16.2
|
|
dhcpIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address for the ethernet interface,
|
|
assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 2 }
|
|
|
|
-- 4.9.1.x.16.3
|
|
dhcpGatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address of the gateway/router for the ethernet
|
|
interface, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 3 }
|
|
|
|
-- 4.9.1.x.16.4
|
|
dhcpSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Subnet Mask for the ethernet
|
|
interface, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 4 }
|
|
|
|
-- 4.9.1.x.16.5
|
|
dhcpDomainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated Domain Name for this
|
|
interface, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 5 }
|
|
|
|
-- 4.9.1.x.16.6
|
|
dhcpDHCPServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the DHCP server IP address used to acquire the
|
|
DHCP settings."
|
|
::= { dhcpEthernetInterface 6 }
|
|
|
|
-- 4.9.1.x.16.7
|
|
dhcpPrimaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Primary DNS server, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 7 }
|
|
|
|
-- 4.9.1.x.16.8
|
|
dhcpSecondaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Secondary DNS server, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 8 }
|
|
|
|
-- 4.9.1.x.16.9
|
|
dhcpTertiaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the tertiary DNS server, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- PPP Interface 1
|
|
-- ********************************************************************************
|
|
-- 4.9.1.x.16
|
|
intEthernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 2 }
|
|
|
|
-- 4.9.1.2.1
|
|
intEthernetInterfaceType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of interface. Indicates 'PPP-1'."
|
|
::= { intEthernetInterface 1 }
|
|
|
|
-- 4.9.1.2.2
|
|
intEthernetInterfaceEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
interfaceDisabled(0),
|
|
interfaceEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable the internal ethernet interface.
|
|
Note: To alter any of the configuration settings for the
|
|
ethernet interface, the following procedure should be used:
|
|
(1) This object should be set to 'interfaceDisabled'
|
|
(2) Make the modifications to other settings
|
|
(3) This object should be set to 'interfaceEnabled'
|
|
(4) Restart the remote supervisor adapter
|
|
|
|
Also note that when attempting to enable this interface, the
|
|
remote IP address is verified to be nonzero. If this verification
|
|
fails, an error response will be returned and the internal ethernet
|
|
interface will be left disabled."
|
|
::= { intEthernetInterface 2 }
|
|
|
|
-- 4.9.1.2.4
|
|
intEthernetInterfaceLocalIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address for the ASM side of the internal ethernet link."
|
|
::= { intEthernetInterface 4 }
|
|
|
|
-- 4.9.1.2.5
|
|
intEthernetInterfaceDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enet10Megabit(3),
|
|
enet100Megabit(4),
|
|
autoSpeed(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the data transfer rate to be used over the ethernet
|
|
interface: 10Mb, 100Mb, or Auto."
|
|
::= { intEthernetInterface 5 }
|
|
|
|
-- 4.9.1.2.6
|
|
intEthernetInterfaceDuplexSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fullDuplex(1),
|
|
halfDuplex(2),
|
|
autoDuplex(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the duplex settings for the data transfer rate to be used over
|
|
the ethernet interface: Half, Full, or Auto."
|
|
::= { intEthernetInterface 6 }
|
|
|
|
-- 4.9.1.2.7
|
|
intEthernetInterfaceLAA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the locally administered MAC address."
|
|
::= { intEthernetInterface 7 }
|
|
|
|
-- 4.9.1.2.9
|
|
intEthernetInterfaceGatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address of the gateway/router for the ethernet
|
|
interface."
|
|
::= { intEthernetInterface 9 }
|
|
|
|
-- 4.9.1.2.10
|
|
intEthernetInterfaceBIA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the burned-in MAC (BIA) address."
|
|
::= { intEthernetInterface 10 }
|
|
|
|
-- 4.9.1.2.13
|
|
intEthernetInterfaceMTU OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Maximum Transmission Unit(MTU) for the ethernet
|
|
interface"
|
|
::= { intEthernetInterface 13 }
|
|
|
|
-- 4.9.1.2.14
|
|
intEthernetInterfaceSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the subnet mask for the ethernet interface."
|
|
::= { intEthernetInterface 14 }
|
|
|
|
-- ********************************************************************************
|
|
-- TCP/IP Protocol Configuration
|
|
-- ********************************************************************************
|
|
-- 4.9.3
|
|
tcpProtocols OBJECT IDENTIFIER ::= { networkConfiguration 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP Agent Configuration
|
|
-- ********************************************************************************
|
|
-- 4.9.3.1
|
|
snmpAgentConfig OBJECT IDENTIFIER ::= { tcpProtocols 1 }
|
|
|
|
|
|
-- 4.9.3.1.1
|
|
snmpSystemContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..48))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 48 byte string that contains the
|
|
SNMP agent contact name. Note: Set snmpSystemAgentEnable
|
|
to disabled before performing a set of this object."
|
|
::= { snmpAgentConfig 1 }
|
|
|
|
-- 4.9.3.1.2
|
|
snmpSystemLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..48))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 48 byte string that contains the
|
|
SNMP agent location name. Note: Set snmpSystemAgentEnable
|
|
to disabled before performing a set of this object."
|
|
::= { snmpAgentConfig 2 }
|
|
|
|
-- 4.9.3.1.3
|
|
snmpSystemAgentTrapsDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
trapsEnabled(0),
|
|
trapsDisabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable SNMP traps. Note: Set snmpSystemAgentEnable
|
|
to disabled before performing a set of this object."
|
|
::= { snmpAgentConfig 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP Agent Community Configuration
|
|
-- ********************************************************************************
|
|
-- 4.9.3.1.4
|
|
snmpAgentCommunityConfig OBJECT IDENTIFIER ::= { snmpAgentConfig 4 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP Community Configuration table
|
|
-- ********************************************************************************
|
|
|
|
snmpCommunityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnmpCommunityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SNMP Community entries"
|
|
::= { snmpAgentCommunityConfig 1 }
|
|
|
|
snmpCommunityEntry OBJECT-TYPE
|
|
SYNTAX SnmpCommunityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP community entries"
|
|
INDEX { snmpCommunityEntryIndex }
|
|
::= { snmpCommunityTable 1 }
|
|
|
|
SnmpCommunityEntry ::= SEQUENCE {
|
|
snmpCommunityEntryIndex INTEGER(0..255),
|
|
snmpCommunityEntryCommunityName OCTET STRING (SIZE(0..15)),
|
|
snmpCommunityEntryCommunityIpAddress1 OCTET STRING (SIZE(0..63)),
|
|
snmpCommunityEntryCommunityIpAddress2 OCTET STRING (SIZE(0..63)),
|
|
snmpCommunityEntryCommunityIpAddress3 OCTET STRING (SIZE(0..63)),
|
|
snmpCommunityEntryCommunityViewType INTEGER(1..3)
|
|
}
|
|
|
|
|
|
snmpCommunityEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for SNMP Agent Community entry."
|
|
::= { snmpCommunityEntry 1 }
|
|
|
|
-- 4.9.3.1.4.1
|
|
snmpCommunityEntryCommunityName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community entry name. Note: Set snmpSystemAgentEnable
|
|
to disabled before performing a set of this object."
|
|
::= { snmpCommunityEntry 2 }
|
|
|
|
-- 4.9.3.1.4.2
|
|
snmpCommunityEntryCommunityIpAddress1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (eg. 9.37.44.2)
|
|
or if DNS is enabled a host name. Note: Set
|
|
snmpSystemAgentEnable to disabled before performing a
|
|
set of this object."
|
|
::= { snmpCommunityEntry 3 }
|
|
|
|
-- 4.9.3.1.4.3
|
|
snmpCommunityEntryCommunityIpAddress2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (eg. 9.37.44.2)
|
|
or if DNS is enabled a host name. Note: Set
|
|
snmpSystemAgentEnable to disabled before performing a
|
|
set of this object."
|
|
::= { snmpCommunityEntry 4 }
|
|
|
|
-- 4.9.3.1.4.4
|
|
snmpCommunityEntryCommunityIpAddress3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (eg. 9.37.44.2)
|
|
or if DNS is enabled a host name. Note: Set
|
|
snmpSystemAgentEnable to disabled before performing a
|
|
set of this object."
|
|
::= { snmpCommunityEntry 5 }
|
|
|
|
|
|
-- 4.9.3.1.4.5
|
|
snmpCommunityEntryCommunityViewType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
read-Traps(1),
|
|
write-Read-Traps(2),
|
|
traps-Only(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Access Level of the SNMPv1 managers. Note this parameter
|
|
is set for each community. Therefore all three managers
|
|
in the same community have the same access level."
|
|
::= { snmpCommunityEntry 6 }
|
|
|
|
-- 4.9.3.1.5
|
|
snmpv1SystemAgentEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable the SNMPv1 agent.
|
|
|
|
Note: To alter any of the configuration settings for the SNMPv1
|
|
agent, the following procedure should be used:
|
|
(1) This object should be set to 'disabled'
|
|
(2) Make the modifications to other settings
|
|
(3) This object should be set to 'enabled'
|
|
(4) Restart the remote supervisor adapter if this mib is changed
|
|
with respect to the value at system bootup time. For example the
|
|
SNMPv1 agent was set to disabled at system bootup time and now
|
|
it is enabled. Then restarting the remote supervisor adaptor is
|
|
required.
|
|
|
|
Also note that when attempting to enable this agent,
|
|
the following are verifed:
|
|
(1) Is there a valid system contact
|
|
(2) Is there a valid system name
|
|
(3) Is there at least one valid community name and for that
|
|
community name is there one valid IP address or hostname
|
|
|
|
If this verification fails an error response will be returned
|
|
and the SNMPv1 agent will be left disabled."
|
|
::= { snmpAgentConfig 5 }
|
|
|
|
-- 4.9.3.1.6
|
|
snmpv3SystemAgentEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable the SNMPv3 agent.
|
|
|
|
Note: To alter any of the configuration settings for the SNMPv3
|
|
agent, the following procedure should be used:
|
|
(1) This object should be set to 'disabled'
|
|
(2) Make the modifications to other settings
|
|
(3) This object should be set to 'enabled'
|
|
(4) Restart the remote supervisor adapter if this mib is changed
|
|
with respect to the value at system bootup time. For example the
|
|
SNMPv3 agent was set to disabled at system bootup time and now
|
|
it is enabled. Then restarting the remote supervisor adaptor is
|
|
required.
|
|
|
|
Also note that when attempting to enable this agent,
|
|
the following are verifed:
|
|
(1) Is there a valid system contact?
|
|
(2) Is there a valid system name?
|
|
|
|
If this verification fails an error response will be returned
|
|
and the SNMPv3 agent will be left disabled."
|
|
|
|
::= { snmpAgentConfig 6 }
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP Agent User Profile Configuration
|
|
-- ********************************************************************************
|
|
|
|
-- 4.9.3.1.9
|
|
snmpAgentUserProfileConfig OBJECT IDENTIFIER ::= { snmpAgentConfig 9 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP User Profile Configuration table
|
|
-- ********************************************************************************
|
|
|
|
snmpUserProfileTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnmpUserProfileEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SNMPv3 User Profile entries"
|
|
::= { snmpAgentUserProfileConfig 1 }
|
|
|
|
snmpUserProfileEntry OBJECT-TYPE
|
|
SYNTAX SnmpUserProfileEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP User Profile entries"
|
|
INDEX { snmpUserProfileEntryIndex }
|
|
::= { snmpUserProfileTable 1 }
|
|
|
|
SnmpUserProfileEntry ::= SEQUENCE {
|
|
snmpUserProfileEntryIndex INTEGER(0..255),
|
|
-- snmpUserProfileEntryUserName OCTET STRING (SIZE(0..31)),
|
|
snmpUserProfileEntryContextName OCTET STRING (SIZE(0..31)),
|
|
snmpUserProfileEntryAuthProt INTEGER(0..255),
|
|
-- snmpUserProfileEntryAuthPassword OCTET STRING (SIZE(0..31)),
|
|
snmpUserProfileEntryPrivProt INTEGER(0..255),
|
|
snmpUserProfileEntryPrivPassword OCTET STRING (SIZE(0..31)),
|
|
snmpUserProfileEntryViewType INTEGER(0..255),
|
|
snmpUserProfileEntryIpAddress OCTET STRING (SIZE(0..63))
|
|
}
|
|
|
|
|
|
snmpUserProfileEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for SNMPv3 Agent User Profile entry."
|
|
::= { snmpUserProfileEntry 1 }
|
|
|
|
|
|
-- snmpUserProfileEntryUserName OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(0..31))
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "SNMPv3 User Profile entry - User name."
|
|
-- ::= { snmpUserProfileEntry 2 }
|
|
|
|
|
|
snmpUserProfileEntryContextName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Context name
|
|
for the user to access MIB objects."
|
|
::= { snmpUserProfileEntry 3 }
|
|
|
|
snmpUserProfileEntryAuthProt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
md5 (2),
|
|
sha (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Authentication Protocol
|
|
supported by the user."
|
|
::= { snmpUserProfileEntry 4 }
|
|
|
|
-- snmpUserProfileEntryAuthPassword OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(0..31))
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "SNMPv3 User Profile entry - Authentication password
|
|
-- for the user."
|
|
-- ::= { snmpUserProfileEntry 5 }
|
|
|
|
snmpUserProfileEntryPrivProt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
des (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Privacy Protocol
|
|
supported by the user."
|
|
::= { snmpUserProfileEntry 6 }
|
|
|
|
snmpUserProfileEntryPrivPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Privacy password
|
|
for the user.
|
|
|
|
NOTE: Value returned for the GET command is
|
|
meaningless for this MIB for security reason."
|
|
::= { snmpUserProfileEntry 7 }
|
|
|
|
snmpUserProfileEntryViewType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
read-Traps(1),
|
|
read-Write-Traps(2),
|
|
traps-Only(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Access level (Get, Set, and
|
|
Traps) of the user. "
|
|
::= { snmpUserProfileEntry 8 }
|
|
|
|
|
|
snmpUserProfileEntryIpAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - IP address or host name.
|
|
Can either be a dotted decimal IP string (eg. 9.37.44.2)
|
|
or if DNS is enabled a host name."
|
|
::= { snmpUserProfileEntry 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- DNS Configuration
|
|
-- ********************************************************************************
|
|
-- 4.9.3.2
|
|
dnsConfig OBJECT IDENTIFIER ::= { tcpProtocols 2 }
|
|
|
|
-- 4.9.3.2.1
|
|
dnsEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dnsDisabled(0),
|
|
dnsEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable the DNS agent.
|
|
|
|
Note: To alter any of the configuration settings for the DNS agent,
|
|
the following procedure should be used:
|
|
(1) This object should be set to 'disabled'
|
|
(2) Make the modifications to other settings
|
|
(3) This object should be set to 'enabled'
|
|
(4) Restart the remote supervisor adapter
|
|
|
|
Also note that when attempting to enable this agent, it is verified
|
|
that there is at least one valid DNS server IP address. If this
|
|
verification fails, an error response will be returned and the DNS
|
|
agent will be left disabled."
|
|
::= { dnsConfig 1 }
|
|
|
|
-- 4.9.3.2.2
|
|
dnsServerIPAddress1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the primary DNS server IP address."
|
|
::= { dnsConfig 2 }
|
|
|
|
-- 4.9.3.2.3
|
|
dnsServerIPAddress2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the secondary DNS server IP address."
|
|
::= { dnsConfig 3 }
|
|
|
|
-- 4.9.3.2.4
|
|
dnsServerIPAddress3 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the tertiary DNS server IP address."
|
|
::= { dnsConfig 4 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SMTP Configuration
|
|
-- ********************************************************************************
|
|
-- 4.9.3.3
|
|
smtpConfig OBJECT IDENTIFIER ::= { tcpProtocols 3 }
|
|
|
|
|
|
-- 4.9.3.3.1
|
|
smtpServerNameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 64 byte string that contains the
|
|
SMTP server host name or IP address (a.b.c.d)."
|
|
::= { smtpConfig 1 }
|
|
|
|
-- 4.9.3.3.2
|
|
attachmentsToEmailAlerts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAttachments(0),
|
|
attachEventLog(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the event log should be attached to
|
|
an email alert."
|
|
::= { smtpConfig 2 }
|
|
|
|
|
|
-- 4.9.3.4.1
|
|
tcpApplicationConfig OBJECT IDENTIFIER ::= { tcpProtocols 4 }
|
|
telnetInactivityTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Default is 120 seconds. Value of zero is no timeout.
|
|
Max value is any positive 4 bytes value."
|
|
::= { tcpApplicationConfig 1 }
|
|
|
|
-- 4.9.3.4.2
|
|
commandModeInactivityTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Default is zero means no timeout. Max value is any positive 4 bytes value."
|
|
::= { tcpApplicationConfig 2 }
|
|
|
|
-- 4.9.3.4.4
|
|
commandModeEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
diabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable TCP Command Mode."
|
|
::= { tcpApplicationConfig 4 }
|
|
|
|
-- 4.9.3.4.5
|
|
slpAddrType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
multicast(0),
|
|
broadcast(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when
|
|
slpAddrType is set to broadast value then the multicast address set in in
|
|
slpMulticastAddt will be ignored."
|
|
::= { tcpApplicationConfig 5 }
|
|
|
|
-- 4.9.3.4.6
|
|
slpMulticastAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Service Locator Protocol Multicast address"
|
|
::= { tcpApplicationConfig 6 }
|
|
|
|
-- 4.9.3.5.x TCP Port Assignment
|
|
tcpPortAssignmentCfg OBJECT IDENTIFIER ::= { tcpProtocols 5 }
|
|
|
|
tcpPortsRestoreDefault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number. Default value is 80. Once changed, the url's have to
|
|
include :port at the end. SP has to be reset for change to take effect.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB."
|
|
::= { tcpPortAssignmentCfg 1 }
|
|
|
|
httpPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number. Default value is 80. Once changed, the url's have to
|
|
include :port at the end. SP has to be reset for change to take effect."
|
|
::= { tcpPortAssignmentCfg 2 }
|
|
|
|
httpsPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SSL port number. Default value is 443. Once changed, the url's have to
|
|
include :port at the end. SP has to be reset for change to take effect."
|
|
::= { tcpPortAssignmentCfg 3 }
|
|
|
|
telnetPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"telnet port number. Default value is 23. SP has to be reset for change
|
|
to take effect."
|
|
::= { tcpPortAssignmentCfg 4 }
|
|
|
|
sshPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SSH port number. Default value is 22. SP has to be reset for change
|
|
to take effect."
|
|
::= { tcpPortAssignmentCfg 5 }
|
|
|
|
snmpAgentPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Agent port number. Default value is 161. SP has to be reset for change
|
|
to take effect."
|
|
::= { tcpPortAssignmentCfg 6 }
|
|
|
|
snmpTrapsPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Traps port number. Default value is 162. SP has to be reset for change
|
|
to take effect."
|
|
::= { tcpPortAssignmentCfg 7 }
|
|
|
|
|
|
-- 4.9.3.6.x LDAP Client Configuration
|
|
ldapClientCfg OBJECT IDENTIFIER ::= { tcpProtocols 6 }
|
|
|
|
-- 4.9.3.6.1
|
|
ldapServer1NameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 64 byte string that contains the
|
|
LDAP server host name or IP address (a.b.c.d)."
|
|
::= { ldapClientCfg 1 }
|
|
|
|
-- 4.9.3.6.2
|
|
ldapServer1PortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LDAP server port number."
|
|
::= { ldapClientCfg 2 }
|
|
|
|
-- 4.9.3.6.3
|
|
ldapServer2NameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 64 byte string that contains the
|
|
LDAP server host name or IP address (a.b.c.d)."
|
|
::= { ldapClientCfg 3 }
|
|
|
|
-- 4.9.3.6.4
|
|
ldapServer2PortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LDAP server port number."
|
|
::= { ldapClientCfg 4 }
|
|
|
|
-- 4.9.3.6.5
|
|
ldapServer3NameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 64 byte string that contains the
|
|
LDAP server host name or IP address (a.b.c.d)."
|
|
::= { ldapClientCfg 5 }
|
|
|
|
-- 4.9.3.6.6
|
|
ldapServer3PortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LDAP server port number."
|
|
::= { ldapClientCfg 6 }
|
|
|
|
-- 4.9.3.6.7
|
|
ldapRootDN OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Distinguished Name for root entry of directory tree.
|
|
An example might look like dn=foobar,dn=com."
|
|
::= { ldapClientCfg 7 }
|
|
|
|
-- 4.9.3.6.8
|
|
ldapUserSearchBaseDN OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"As part of the user authentication process, it is necessary to search
|
|
the LDAP server for one or more attributes associated with a particular
|
|
user. Any search request must specify the base DN for the actual search.
|
|
This field specifies the base DN which should be used to search the User
|
|
directory. An example might look like cn=users,dn=foobar,dn=com. If this
|
|
field is left blank, the Root DN will be used as the search base instead.
|
|
As mentioned, user searches are part of the authentication process. They
|
|
are carried out to retrieve information about the user such as login
|
|
permissions, callback number, and group memberships. For Version 2.0 LDAP
|
|
clients, it is strongly encouraged that this parameter be configured,
|
|
otherwise a search using the root DN may not succeed (as seen on Active
|
|
Directory servers)."
|
|
::= { ldapClientCfg 8 }
|
|
|
|
-- 4.9.3.6.9
|
|
ldapGroupFilter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This filter is used for group authentication. It specifies what group or
|
|
groups that this MM belongs to. If left blank, group authentication is
|
|
disabled. Otherwise, group authentication will be performed against the
|
|
filter. The filter can be a specific group name (eg. RSAWest), a wildcard (*)
|
|
which matches everything, or a wildcard with a prefix (eg. RSA*). The default
|
|
filter is RSA*.
|
|
After user authentication, group authentication will take place, whereby an
|
|
attempt will be made to match the group or groups (that the user belongs to)
|
|
to the group filter defined here. If there is no match, the user will not pass
|
|
authentication and will be blocked. If there is a match, the login permissions
|
|
for the user will be retrieved from the matched group(s), unless the user
|
|
already has login permissions assigned directly from the user record retrieved
|
|
from the LDAP server."
|
|
::= { ldapClientCfg 9 }
|
|
|
|
-- 4.9.3.6.10
|
|
ldapBindingMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
anonymousAuthentication(0),
|
|
clientAuthentication(1),
|
|
userPrincipalName(2),
|
|
strictUserPrincipalName(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"On initial binds to the LDAP server during user authentication, there are
|
|
three options:
|
|
Anonymous authentication: Bind attempt is made without a client DN or password.
|
|
If the bind is successful, a search will be requested in order to find an entry
|
|
on the LDAP server for the user attempting to login. If an entry is found, a
|
|
second attempt to bind will be attempted, this time with the user's DN and
|
|
password. If this succeeds, the user is deemed to have passed the user
|
|
authentication phase. Group authentication is then attempted if it is enabled.
|
|
Client authentication: Bind attempt is made with client DN and password
|
|
specified by this configuration parameter. If the bind is successful, we
|
|
proceed as above.
|
|
User Principal Name (UPN): Bind attempt is made directly with the credentials
|
|
used during the login process. If this succeeds, the user is deemed to have
|
|
passed the user authentication phase. Note that for Active Directory servers,
|
|
the userid can have the form someuser@somedomain or simply someuser.
|
|
Strict UPN: This is the same as UPN above, except that the userid must have
|
|
the form someuser@somedomain. The string entered by the user will be parsed
|
|
for the @ symbol."
|
|
::= { ldapClientCfg 10 }
|
|
|
|
-- 4.9.3.6.11
|
|
ldapClientAuthenticationDN OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The initial bind to the LDAP server during user authentication can be
|
|
performed with anonymous authentication, client based authentication, or UPN.
|
|
The client based option requires a client DN and password as parameters to
|
|
the bind request. These parameters are configured here. Note that the password
|
|
can be left blank."
|
|
::= { ldapClientCfg 11 }
|
|
|
|
-- 4.9.3.6.12
|
|
ldapClientAuthenticationPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The client authentication password"
|
|
::= { ldapClientCfg 12 }
|
|
|
|
-- 4.9.3.6.13
|
|
ldapUIDsearchAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the binding method selected is Anonymous authentication or Client
|
|
authentication, the initial bind to the LDAP server is followed by a search
|
|
request aimed at retrieving specific information about the user, including the
|
|
user's DN, login permissions, and group ownerships. In order to retrieve this
|
|
information, the search request must specify the attribute name used to
|
|
represent userids on that server. Specifically, this name is used as a search
|
|
filter against the login id entered by the user. This attribute name is
|
|
configured here. If this field is left blank, a default of uid is used during
|
|
user authentication.
|
|
For example, on Active Directory servers, the attribute name used for userids
|
|
is often sAMAccoutName.
|
|
When the binding method selected is UPN or Strict UPN, this field defaults
|
|
automatically to userPrincipalName during user authentication if the userid
|
|
entered has the form userid@somedomain."
|
|
::= { ldapClientCfg 13 }
|
|
|
|
-- 4.9.3.6.14
|
|
ldapGroupSearchAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the MM Group Filter name is configured, it is necessary to retrieve
|
|
from the LDAP server the list of groups that a particular user belongs to.
|
|
This is required to do group authentication. In order to retrieve this list,
|
|
the search filter sent to the server must specify the attribute name associated
|
|
with groups. This field specifies this attribute name.
|
|
If this field is left blank, the attribute name in the filter will default
|
|
to memberOf."
|
|
::= { ldapClientCfg 14 }
|
|
|
|
-- 4.9.3.6.15
|
|
ldapLoginPermissionAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When a user successfully authenticates via a LDAP server, it is necessary
|
|
to retrieve the login permissions for this user. In order to retrieve these
|
|
permissions, the search filter sent to the server must specify the attribute
|
|
name associated with login permissions. This field specifies this attribute
|
|
name."
|
|
::= { ldapClientCfg 15 }
|
|
|
|
-- 4.9.3.6.16
|
|
ldapUseDNSOrPreConfiguredServers OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
usePreConfiguredLDAPServers (0),
|
|
useDNSToFindLDAPServers (1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MM contains a Version 2.0 LDAP Client that may be configured to provide
|
|
user authentication through one or more LDAP servers. The LDAP server(s) to be
|
|
used for authentication can be discovered dynamically or manually pre-configured.
|
|
|
|
If the usePreConfiguredLDAPServers option is selected, up to 3 LDAP servers can
|
|
be configured. Simply enter the server's IP address or hostname (assuming DNS
|
|
is enabled). The port number for each server is optional. If left blank,
|
|
the default value of 389 is used for non-secured LDAP connections. For secured
|
|
connections, the default is 636. At least one server must be configured.
|
|
|
|
If the useDNSToFindLDAPServers is selected, the mechanisms described by RFC2782
|
|
(A DNS RR for specifying the location of services) are applied to find the
|
|
server(s). This is known as DNS SRV."
|
|
::= { ldapClientCfg 16 }
|
|
|
|
-- 4.9.3.6.17
|
|
ldapDomainSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
extractSearchDomainFromLoginID (0),
|
|
useOnlyConfiguredSearchDomainBelow (1),
|
|
tryLoginFirstThenConfiguredValue (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DNS SRV request sent to the DNS server must specify a domain name.
|
|
The LDAP client will determine where to get this domain name based on one
|
|
of the following three options:
|
|
|
|
- extractSearchDomainFromLoginID: With this option, the LDAP client will
|
|
use the domain name in the login id. For example, if the login id is
|
|
joesmith@mycompany.com, the domain name equals mycompany.com. If the domain
|
|
name cannot be extracted, the DNS SRV will fail, causing the user
|
|
authentication to fail automatically.
|
|
|
|
- useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client
|
|
will use the domain name configured in the Search Domain parameter.
|
|
|
|
- tryLoginFirstThenConfiguredValue: With this option, the LDAP client will
|
|
first attempt to extract the domain name from the login id. If this succeeds,
|
|
this domain name will be used in the DNS SRV request. If there is no domain
|
|
name present in the login id, the LDAP client will instead use the configured
|
|
Search Domain parameter as the domain name in the DNS SRV request.
|
|
If nothing is configured, user authentication will fail immediately."
|
|
::= { ldapClientCfg 17 }
|
|
|
|
-- 4.9.3.6.18
|
|
ldapSearchDomain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter may be used as the domain name in the DNS SRV request,
|
|
depending on how the Domain Source parameter is configured."
|
|
::= { ldapClientCfg 18 }
|
|
|
|
-- 4.9.3.6.19
|
|
ldapServiceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DNS SRV request sent to the DNS server must also specify a service name.
|
|
The configured value will be used for this purpose. If left blank, the default
|
|
value used is 'ldap'. Note that the DNS SRV request must also specify a protocol
|
|
name. This defaults to 'tcp' and is not configurable."
|
|
::= { ldapClientCfg 19 }
|
|
|
|
-- ********************************************************************************
|
|
-- Uplink Check Configuration
|
|
-- ********************************************************************************
|
|
-- 4.9.3.7
|
|
uplinkCheckConfig OBJECT IDENTIFIER ::= { tcpProtocols 7 }
|
|
|
|
-- 4.9.3.7.1
|
|
uplinkCheckEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uplinkCheckDisabled(0),
|
|
uplinkCheckEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable network uplink checking."
|
|
::= { uplinkCheckConfig 1 }
|
|
|
|
-- 4.9.3.7.2
|
|
uplinkCheckDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Delay, in minutes, between discovery of a failed network uplink and
|
|
the subsequent MM failover."
|
|
::= { uplinkCheckConfig 2 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SOL (Serial Over LAN) Configuration
|
|
-- ********************************************************************************
|
|
-- 4.10
|
|
solConfiguration OBJECT IDENTIFIER ::= { configureSP 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- SOL Global Configuration
|
|
-- ********************************************************************************
|
|
-- 4.10.1
|
|
solGlobalConfig OBJECT IDENTIFIER ::= { solConfiguration 1 }
|
|
|
|
-- 4.10.1.1
|
|
solEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
solDiabled(0),
|
|
solEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable SOL dynamically."
|
|
::= { solGlobalConfig 1 }
|
|
|
|
-- 4.10.1.2
|
|
solVlanId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SOL VLAN Id number. Valid number is from 1 to 4095."
|
|
::= { solGlobalConfig 2 }
|
|
|
|
-- 4.10.1.3
|
|
solAccumulateTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value specifies how much time in milisecond SOL to buffer data before
|
|
sending the next SOL packet since the last SOL packet was transmitted.
|
|
Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value
|
|
is not in 5 ms increment will be truncated to a nearest 5s. Default value
|
|
is 5 ms."
|
|
::= { solGlobalConfig 3 }
|
|
|
|
-- 4.10.1.4
|
|
solCharSendThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value specifies how many characters SOL to buffer before
|
|
sending the next SOL packet since the last SOL packet was transmitted.
|
|
Valid value is from 1 to 255"
|
|
::= { solGlobalConfig 4 }
|
|
|
|
-- 4.10.1.5
|
|
solRetry OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted.
|
|
Packet will be dropped if no ACK/NACK received by the time retries expired."
|
|
::= { solGlobalConfig 5 }
|
|
|
|
-- 4.10.1.6
|
|
solRetryInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Retry Interval in 10 ms increment. Sets the time that the SOL will
|
|
wait before the first retry and the time between retries when sending SOL
|
|
packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms
|
|
increment. 0 means retries will be sent back-to-back."
|
|
::= { solGlobalConfig 6 }
|
|
|
|
solExitToCliKeySeq OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the keystroke sequence used to escape out of SOL session and back to CLI
|
|
console. This sequence must have at least one character. The caret symbol (^)
|
|
has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that
|
|
map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage
|
|
return). All ocurrences of ^ will be interpreted as part of a Ctrl sequence.
|
|
Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences.
|
|
The default value for this field is '^[(' i.e. ESC followed by (."
|
|
::= { solGlobalConfig 7 }
|
|
|
|
solResetBladeKeySeq OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the keystroke sequence used to reset the blade while in SOL session
|
|
console. This sequence must have at least one character. The caret symbol (^)
|
|
has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that
|
|
map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage
|
|
return). All ocurrences of ^ will be interpreted as part of a Ctrl sequence.
|
|
Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences.
|
|
The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R."
|
|
::= { solGlobalConfig 8 }
|
|
|
|
|
|
-- 4.10.2 Blade SOL config
|
|
solBladeConfig OBJECT IDENTIFIER ::= { solConfiguration 2 }
|
|
|
|
|
|
-- 4.10.2.1
|
|
solBladeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SolBladeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SOL Blade configuration table."
|
|
::= { solBladeConfig 1 }
|
|
|
|
-- 4.10.2.1.1
|
|
solBladeEntry OBJECT-TYPE
|
|
SYNTAX SolBladeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SOL Blade table entry"
|
|
INDEX { solBladeIndex }
|
|
::= { solBladeTable 1 }
|
|
|
|
SolBladeEntry ::= SEQUENCE {
|
|
solBladeIndex INTEGER,
|
|
solBladeName OCTET STRING,
|
|
solBladeEnable INTEGER,
|
|
solBladeIpAddr IpAddress,
|
|
solBladeSessionStatus INTEGER,
|
|
solBladeCapability INTEGER
|
|
}
|
|
|
|
-- 4.10.2.1.1.1
|
|
solBladeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SOL Blade table index."
|
|
::= { solBladeEntry 1 }
|
|
|
|
-- 4.10.2.1.1.2
|
|
solBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { solBladeEntry 2 }
|
|
|
|
-- 4.10.2.1.1.3
|
|
solBladeEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
solBladeDiabled(0),
|
|
solBladeEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable a SOL on a blade."
|
|
::= { solBladeEntry 3 }
|
|
|
|
-- 4.10.2.1.1.4
|
|
solBladeIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Blade."
|
|
::= { solBladeEntry 4 }
|
|
|
|
-- 4.10.2.1.1.5
|
|
solBladeSessionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
solSessionNotReady(0),
|
|
solSessionReady(1),
|
|
solSessionActive(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of a blade SOL session:
|
|
solSessionNotReady: no SOL session connected to the blade.
|
|
solSessionReady: there is an SOL session to the blade.
|
|
solSessionActive: there is an SOL session to the blade and there is a
|
|
client using the SOL session."
|
|
::= { solBladeEntry 5 }
|
|
|
|
-- 4.10.2.1.1.6
|
|
solBladeCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notSupport(0),
|
|
support(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"display whether or not the blade support SOL feature."
|
|
::= { solBladeEntry 6 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco System Management
|
|
-- ************************************************************************
|
|
-- 5.1
|
|
|
|
-- ************************************************************************
|
|
|
|
telcoAlarmReq OBJECT IDENTIFIER ::= { telcoManagement 1 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Set A Software Alarm
|
|
-- ************************************************************************
|
|
-- 5.1.1
|
|
telcoAlarmSet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Create a software alarm. An input octet string consists of the
|
|
alarm severity level and the alarm description (40 bytes max).
|
|
The following severity levels are valid :
|
|
CRT Critical
|
|
MJR Major
|
|
MNR Minor
|
|
|
|
NOTE 1: Value returned for the GET command is meaningless for
|
|
this MIB.
|
|
|
|
NOTE 2: This MIB is for Blade Center Telco only."
|
|
::= { telcoAlarmReq 1 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Ack an Alarm
|
|
-- ************************************************************************
|
|
-- 5.1.2
|
|
telcoAlarmAck OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledge an alarm. An input octet string consists of the
|
|
alarm key ID expressed as 'mmm:aaa:ggg:iii' where:
|
|
m : Module ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
a : Alarm ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
g : Gen ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
i : GenInfo ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
|
|
NOTE 1: Value returned for the GET command is meaningless for
|
|
this MIB.
|
|
|
|
NOTE 2: This MIB is for Blade Center Telco only."
|
|
::= { telcoAlarmReq 2 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Clear an Alarm
|
|
-- ************************************************************************
|
|
-- 5.1.3
|
|
telcoAlarmClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear an active alarm. An input octet string consists of the
|
|
alarm key ID expressed as 'mmm:aaa:ggg:iii' where:
|
|
m : Module ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
a : Alarm ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
g : Gen ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
i : GenInfo ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
|
|
NOTE1 : Value returned for the GET command is meaningless for
|
|
this MIB.
|
|
|
|
NOTE 2: This MIB is for Blade Center Telco only."
|
|
::= { telcoAlarmReq 3 }
|
|
|
|
|
|
|
|
-- ************************************************************************
|
|
-- 5.2
|
|
-- ************************************************************************
|
|
|
|
-- telcoThresholds OBJECT IDENTIFIER ::= { telcoManagement 2 }
|
|
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Threshold Table
|
|
-- ************************************************************************
|
|
-- 5.2.1
|
|
|
|
-- telcoTempThresholds OBJECT IDENTIFIER ::= { telcoThresholds 1 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold table
|
|
-- ************************************************************************
|
|
-- 5.2.1.1
|
|
|
|
-- telcoTempThresholdsTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF TelcoTempThresholdsEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Table of Temperature Threshold summary.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholds 1 }
|
|
--
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entries
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1
|
|
|
|
-- telcoTempThresholdsEntry OBJECT-TYPE
|
|
-- SYNTAX TelcoTempThresholdsEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Thresholds entry
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- INDEX { telcoTempThresholdsIndex }
|
|
-- ::= { telcoTempThresholdsTable 1 }
|
|
|
|
-- TelcoTempThresholdsEntry ::= SEQUENCE {
|
|
-- telcoTempThresholdsIndex INTEGER,
|
|
-- telcoTempThresholdsName OCTET STRING,
|
|
-- telcoTempThresholdsLCRT OCTET STRING,
|
|
-- telcoTempThresholdsLCRTH OCTET STRING,
|
|
-- telcoTempThresholdsLMJR OCTET STRING,
|
|
-- telcoTempThresholdsLMJRH OCTET STRING,
|
|
-- telcoTempThresholdsLMNR OCTET STRING,
|
|
-- telcoTempThresholdsLMNRH OCTET STRING,
|
|
-- telcoTempThresholdsHMNRH OCTET STRING,
|
|
-- telcoTempThresholdsHMNR OCTET STRING,
|
|
-- telcoTempThresholdsHMJRH OCTET STRING,
|
|
-- telcoTempThresholdsHMJR OCTET STRING,
|
|
-- telcoTempThresholdsHCRTH OCTET STRING,
|
|
-- telcoTempThresholdsHCRT OCTET STRING,
|
|
-- telcoTempThresholdsDFT OCTET STRING,
|
|
-- telcoTempThresholdsLHyst OCTET STRING,
|
|
-- telcoTempThresholdsHHyst OCTET STRING
|
|
-- }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Index
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.1
|
|
|
|
-- telcoTempThresholdsIndex OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Thresholds index.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 1 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Name
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.2
|
|
|
|
-- telcoTempThresholdsName OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Threshold Name. The values
|
|
-- and meanings are as follows:
|
|
-- MM : Management Module Temperature
|
|
-- SYS : System Temperature
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 2 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Low Critical
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.3
|
|
|
|
-- telcoTempThresholdsLCRT OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Low Critical Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 3 }
|
|
--
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Low Critical Reset
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.4
|
|
--
|
|
-- telcoTempThresholdsLCRTH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Low Critical Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 4 }
|
|
--
|
|
--
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Low Major
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.5
|
|
--
|
|
-- telcoTempThresholdsLMJR OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Low Major Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 5 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Low Major Reset
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.6
|
|
|
|
-- telcoTempThresholdsLMJRH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Low Major Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 6 }
|
|
--
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Low Minor
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.7
|
|
|
|
-- telcoTempThresholdsLMNR OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Low Minor Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 7 }
|
|
--
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Low Minor Reset
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.8
|
|
|
|
-- telcoTempThresholdsLMNRH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Low Minor Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 8 }
|
|
--
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - High Minor Reset
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.9
|
|
|
|
-- telcoTempThresholdsHMNRH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature High Minor Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 9 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - High Minor
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.10
|
|
|
|
-- telcoTempThresholdsHMNR OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature High Minor Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 10 }
|
|
--
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - High Major Reset
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.11
|
|
|
|
-- telcoTempThresholdsHMJRH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature High Major Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 11 }
|
|
--
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - High Major
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.12
|
|
|
|
-- telcoTempThresholdsHMJR OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature High Major Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 12 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - High Critical Reset
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.13
|
|
|
|
-- telcoTempThresholdsHCRTH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature High Critical Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 13 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - High Critical
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.14
|
|
|
|
-- telcoTempThresholdsHCRT OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature High Critical Threshold value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 14 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Default Value
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.15
|
|
|
|
-- telcoTempThresholdsDFT OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Default Threshold value. The settings
|
|
-- are for the following components:
|
|
-- MM : Management Module Temperature
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 15 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Lower Hysteresis
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.16
|
|
|
|
-- telcoTempThresholdsLHyst OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Lower Hysteresis value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 16 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Temperature Threshold Entry - Upper Hysteresis
|
|
-- ************************************************************************
|
|
-- 5.2.1.1.1.17
|
|
|
|
-- telcoTempThresholdsHHyst OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Temperature Upper Hysteresis value.
|
|
-- An octet string expressed as 'sddd.dd Centigrade' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
--
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoTempThresholdsEntry 17 }
|
|
--
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold
|
|
-- ************************************************************************
|
|
-- 5.2.2
|
|
|
|
-- telcoVoltageThresholds OBJECT IDENTIFIER ::= { telcoThresholds 2 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Table
|
|
-- ***********************************************************************
|
|
-- 5.2.2.1
|
|
|
|
-- telcoVoltageThresholdsTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF TelcoVoltageThresholdsEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Table of Voltage Threshold summary.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholds 1 }
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1
|
|
|
|
-- telcoVoltageThresholdsEntry OBJECT-TYPE
|
|
-- SYNTAX TelcoVoltageThresholdsEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Thresholds entry
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- INDEX { telcoVoltageThresholdsIndex }
|
|
-- ::= { telcoVoltageThresholdsTable 1 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry Sequence
|
|
-- ************************************************************************
|
|
|
|
-- TelcoVoltageThresholdsEntry ::= SEQUENCE {
|
|
-- telcoVoltageThresholdsIndex INTEGER,
|
|
-- telcoVoltageThresholdsName OCTET STRING,
|
|
-- telcoVoltageThresholdsLCRT OCTET STRING,
|
|
-- telcoVoltageThresholdsLCRTH OCTET STRING,
|
|
-- telcoVoltageThresholdsLMJR OCTET STRING,
|
|
-- telcoVoltageThresholdsLMJRH OCTET STRING,
|
|
-- telcoVoltageThresholdsLMNR OCTET STRING,
|
|
-- telcoVoltageThresholdsLMNRH OCTET STRING,
|
|
-- telcoVoltageThresholdsHMNRH OCTET STRING,
|
|
-- telcoVoltageThresholdsHMNR OCTET STRING,
|
|
-- telcoVoltageThresholdsHMJRH OCTET STRING,
|
|
-- telcoVoltageThresholdsHMJR OCTET STRING,
|
|
-- telcoVoltageThresholdsHCRTH OCTET STRING,
|
|
-- telcoVoltageThresholdsHCRT OCTET STRING,
|
|
-- telcoVoltageThresholdsDFT OCTET STRING,
|
|
-- telcoVoltageThresholdsLHyst OCTET STRING,
|
|
-- telcoVoltageThresholdsHHyst OCTET STRING
|
|
-- }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Index
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.1
|
|
|
|
-- telcoVoltageThresholdsIndex OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Thresholds index.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 1 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Name
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.2
|
|
|
|
-- telcoVoltageThresholdsName OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Threshold Name. The values
|
|
-- and meanings are as follows:
|
|
-- Plus 5 Volts : +5 Volt power supply voltage
|
|
-- Plus 3.3 Volts : +3.3 Volt power supply voltage
|
|
-- Plus 12 Volts : +12 Volt power supply voltage
|
|
-- Minus 5 Volts : -5 Volt power supply voltage
|
|
-- Plus 2.5 Volts : +2.5 Volt power supply voltage
|
|
-- Plus 1.8 Volts : +1.8 Volt power supply voltage
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 2 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Low Critical
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.3
|
|
|
|
-- telcoVoltageThresholdsLCRT OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Low Critical Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 3 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Low Critical Reset
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.4
|
|
|
|
-- telcoVoltageThresholdsLCRTH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Low Critical Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 4 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Low Major
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.5
|
|
|
|
-- telcoVoltageThresholdsLMJR OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Low Major Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 5 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Low Major Reset
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.6
|
|
|
|
-- telcoVoltageThresholdsLMJRH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Low Major Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 6 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Low Minor
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.7
|
|
|
|
-- telcoVoltageThresholdsLMNR OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Low Minor Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 7 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Low Minor Reset
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.8
|
|
|
|
-- telcoVoltageThresholdsLMNRH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Low Minor Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 8 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - High Minor Reset
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.9
|
|
|
|
-- telcoVoltageThresholdsHMNRH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage High Minor Reset Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 9 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - High Minor
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.10
|
|
|
|
-- telcoVoltageThresholdsHMNR OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage High Minor Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 10 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - High Major Reset
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.11
|
|
|
|
-- telcoVoltageThresholdsHMJRH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage High Major Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 11 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - High Major
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.12
|
|
|
|
-- telcoVoltageThresholdsHMJR OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage High Major Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 12 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - High Critical Reset
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.13
|
|
|
|
-- telcoVoltageThresholdsHCRTH OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage High Critical Reset (Hysteresis) Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 13 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - High Critical
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.14
|
|
|
|
-- telcoVoltageThresholdsHCRT OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage High Critical Threshold value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' or 'Not Writeable' indicates
|
|
-- that the given monitor is not supported on this system.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 14 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Default
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.15
|
|
|
|
-- telcoVoltageThresholdsDFT OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Default Threshold value. The settings
|
|
-- are for the following components:
|
|
-- Plus 5 Volts : +5 Volt power supply voltage
|
|
-- Plus 3.3 Volts : +3.3 Volt power supply voltage
|
|
-- Plus 12 Volts : +12 Volt power supply voltage
|
|
-- Minus 5 Volts : -5 Volt power supply voltage
|
|
-- Plus 2.5 Volts : +2.5 Volt power supply voltage
|
|
-- Plus 1.8 Volts : +1.8 Volt power supply voltage
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 15 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Lower Hysteresis
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.16
|
|
|
|
-- telcoVoltageThresholdsLHyst OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Lower Hysteresis value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 16 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco Voltage Threshold Entry - Upper Hysteresis
|
|
-- ************************************************************************
|
|
-- 5.2.2.1.1.17
|
|
|
|
-- telcoVoltageThresholdsHHyst OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Telco Voltage Upper Hysteresis value.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
--
|
|
-- NOTE: This MIB is for Blade Center Telco only."
|
|
-- ::= { telcoVoltageThresholdsEntry 17 }
|
|
|
|
-- ************************************************************************
|
|
-- Telco OEM grouping
|
|
-- ************************************************************************
|
|
-- 5.127
|
|
|
|
telcoOEM OBJECT IDENTIFIER ::= { telcoManagement 127 }
|
|
|
|
telcoOEMs OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A bitmap of information about the contents of this subtree. The
|
|
bitmap is a variable length string containing a list of 1's and 0's.
|
|
Every bit that is set to 1 has a corresponding subtree entry that
|
|
is supported in firmware, while a 0 means that the subtree entry
|
|
is unavailable."
|
|
::= { telcoOEM 1 }
|
|
|
|
|
|
-- *********************************************************************************
|
|
-- System Services
|
|
-- ********************************************************************************
|
|
-- ********************************************************************************
|
|
-- System Watch Dog Timers
|
|
-- currently not supported in cdttable
|
|
-- ********************************************************************************
|
|
-- 5.1
|
|
-- serverTimers OBJECT IDENTIFIER ::= { generalSystemSettings 1 }
|
|
--
|
|
-- 5.1.1
|
|
-- serverPost OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- disabled(0),
|
|
-- threeAndHalfMinutes(7),
|
|
-- fourMinutes(8),
|
|
-- fourAndHalfMinutes(9),
|
|
-- fiveMinutes(10),
|
|
-- sevenAndHalfMinutes(15),
|
|
-- tenMinutes(20),
|
|
-- fifteenMinutes(30),
|
|
-- twentyMinutes(40),
|
|
-- thirtyMinutes(60),
|
|
-- oneHour(120),
|
|
-- twoHours(240)
|
|
-- }
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Number in 30 second intervals the ASM will wait
|
|
-- for the server to complete power on self test (POST).
|
|
-- If the system fails to complete
|
|
-- POST within this time, the ASM will generate a
|
|
-- POST timeout alert (if enabled) and automatically restart the system
|
|
-- one time. Once the system is restarted, the POST
|
|
-- watchdog is automatically disabled until the operating system is
|
|
-- shutdown and the server is power cycled."
|
|
-- ::= { serverTimers 1 }
|
|
--
|
|
-- 5.1.2
|
|
-- oSHang OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- disabled(0),
|
|
-- twoAndHalfMinutes(150),
|
|
-- threeMinutes(180),
|
|
-- threeAndHalfMinutes(210),
|
|
-- fourMinutes(240)
|
|
-- }
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Number, in 1 second intervals, the ASM will
|
|
-- check to insure the OS is operating properly.
|
|
-- If the operating system fails to respond within 6 seconds to one
|
|
-- of these checks, the remote supervisor adapter will generate
|
|
-- an O/S Timeout alert (if enabled) and automatically restart the
|
|
-- system one time. Once the system is restarted, the O/S Watchdog
|
|
-- is automatically disabled until the operating
|
|
-- system is shutdown and the server is power cycled."
|
|
-- ::= { serverTimers 2 }
|
|
--
|
|
-- 5.1.3
|
|
-- oSLoader OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- disabled(0),
|
|
-- oneHalfMinutes(1),
|
|
-- oneMinutes(2),
|
|
-- oneAndHalfMinutes(3),
|
|
-- twoMinutes(4),
|
|
-- twoAndHalfMinutes(5),
|
|
-- threeMinutes(6),
|
|
-- fourMinutes(8),
|
|
-- fourAndHalfMinutes(9),
|
|
-- fiveMinutes(10),
|
|
-- fiveAndHalfMinutes(11),
|
|
-- sevenAndHalfMinutes(15),
|
|
-- tenMinutes(20),
|
|
-- fifteenMinutes(30),
|
|
-- twentyMinutes(40),
|
|
-- thirtyMinutes(60),
|
|
-- oneHour(120),
|
|
-- twoHours(240)
|
|
-- }
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Number in 30 second intervals the remote ASM will wait
|
|
-- between completion of POST and the end of loading the OS.
|
|
-- If this interval is exceeded, the ASM will
|
|
-- generate a Loader Timeout alert (if enabled) and automatically restart
|
|
-- the system one time. Once the system is restarted, the
|
|
-- Loader Timeout is automatically disabled until the operating
|
|
-- system is shutdown and the server is power cycled."
|
|
-- ::= { serverTimers 3 }
|
|
--
|
|
|
|
--
|
|
-- System Power Control
|
|
--
|
|
|
|
-- ********************************************************************************
|
|
-- System Power off control
|
|
-- ********************************************************************************
|
|
-- 6.3
|
|
-- powerOffSystemControl OBJECT IDENTIFIER ::= { systemPower 3 }
|
|
--
|
|
-- 6.3.2
|
|
-- powerOffImmediately OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- execute(1)
|
|
-- }
|
|
-- ACCESS write-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Power off the system immediately."
|
|
-- ::= { powerOffSystemControl 2 }
|
|
--
|
|
-- ********************************************************************************
|
|
-- System Power on control
|
|
-- ********************************************************************************
|
|
-- 6.4
|
|
-- powerOnSystemControl OBJECT IDENTIFIER ::= { systemPower 4 }
|
|
--
|
|
-- 6.4.2
|
|
-- powerOnImmediately OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- execute(1)
|
|
-- }
|
|
-- ACCESS write-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Power on the system immediately."
|
|
-- ::= { powerOnSystemControl 2 }
|
|
--
|
|
|
|
-- ********************************************************************************
|
|
-- Restart Control
|
|
-- ********************************************************************************
|
|
|
|
-- 7.2
|
|
-- restartSystemImmediately OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- execute(1)
|
|
-- }
|
|
-- ACCESS write-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Restart the system immediately and then the boot OS."
|
|
-- ::= { restartReset 2 }
|
|
--
|
|
|
|
-- 7.4
|
|
restartSPImmediately OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart the ASM immediately.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for
|
|
this MIB."
|
|
::= { restartReset 4 }
|
|
|
|
-- 7.7
|
|
switchOverRedundantMM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch over to the redundant Management Module.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for
|
|
this MIB."
|
|
::= { restartReset 7 }
|
|
|
|
-- 2.5.3 + 7.4???
|
|
resetSPConfigAndRestart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Will cause all the ASM information to be reset to it's
|
|
initial factory defaults (all previous configuration
|
|
information is lost) and the ASM will be re-started.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { restartReset 20 }
|
|
|
|
-- ********************************************************************************
|
|
-- processorBlade
|
|
-- ********************************************************************************
|
|
--This group of objects provides information specific to blades
|
|
-- 22.1
|
|
processorBlade OBJECT IDENTIFIER ::= { bladeCenter 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- Media and I/O
|
|
-- ********************************************************************************
|
|
-- 22.1.1
|
|
bladeMediaTrayBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allocate the media tray to a blade of a BladeCenter system.
|
|
On a get command, a blade ID of 0x00 means that no blade is
|
|
currently using the device. A set command cannot allocate
|
|
the media tray to the management module."
|
|
::= { processorBlade 1 }
|
|
|
|
-- 22.1.2
|
|
bladeKVMBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allocate the keyboard, video, and mouse ports (KVM) to a blade
|
|
of a blade runner system. On a get command, a blade ID of 0x00
|
|
means that no blade is currently using the devices. A set
|
|
command cannot allocate the KVM to the management module."
|
|
::= { processorBlade 2 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade boot sequence
|
|
-- ********************************************************************************
|
|
-- 22.1.3
|
|
bladeBootSequenceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeBootSequenceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade boot sequence information. Contains
|
|
the boot sequence information for each blade."
|
|
::= { processorBlade 3 }
|
|
|
|
bladeBootSequenceEntry OBJECT-TYPE
|
|
SYNTAX BladeBootSequenceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Boot sequence entry"
|
|
INDEX { bootSequenceIndex }
|
|
::= { bladeBootSequenceTable 1 }
|
|
|
|
|
|
BladeBootSequenceEntry ::= SEQUENCE {
|
|
bootSequenceIndex INTEGER,
|
|
bootSequenceBladeId INTEGER,
|
|
bootSequenceBladeExists INTEGER,
|
|
bootSequenceBladePowerState INTEGER,
|
|
bootSequenceBladeHealthState INTEGER,
|
|
bootSequenceBladeName OCTET STRING,
|
|
bootSequence1 INTEGER,
|
|
bootSequence2 INTEGER,
|
|
bootSequence3 INTEGER,
|
|
bootSequence4 INTEGER
|
|
}
|
|
|
|
bootSequenceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade boot sequence index."
|
|
::= { bladeBootSequenceEntry 1 }
|
|
|
|
bootSequenceBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeBootSequenceEntry 2 }
|
|
|
|
bootSequenceBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeBootSequenceEntry 3 }
|
|
|
|
bootSequenceBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeBootSequenceEntry 4 }
|
|
|
|
bootSequenceBladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade server.
|
|
1 = good, 2 = warning, 3 = bad."
|
|
::= { bladeBootSequenceEntry 5 }
|
|
|
|
bootSequenceBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeBootSequenceEntry 6 }
|
|
|
|
bootSequence1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noneSpecified(0),
|
|
floppy(1),
|
|
cdrom(2),
|
|
hardDrive0(3),
|
|
hardDrive1(4),
|
|
hardDrive2(5),
|
|
hardDrive3(6),
|
|
networkBoot(7),
|
|
notAvailable(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The boot device for this blade boot sequence. Note that some types
|
|
of blades don't support floppy disk drive. It is recommended that all
|
|
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
|
|
If there is any duplication of the configured boot sequence and the
|
|
current configuration, the two boot sequence will be swapped.
|
|
For an example: the current boot sequence is
|
|
1=HD0, 2=CD, 3=FD, 4=HD1
|
|
If the user wants to configure 1=FD which is a duplication of 3 then the
|
|
new boot sequence will be:
|
|
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)"
|
|
::= { bladeBootSequenceEntry 7 }
|
|
|
|
bootSequence2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noneSpecified(0),
|
|
floppy(1),
|
|
cdrom(2),
|
|
hardDrive0(3),
|
|
hardDrive1(4),
|
|
hardDrive2(5),
|
|
hardDrive3(6),
|
|
networkBoot(7),
|
|
notAvailable(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The boot device for this blade boot sequence. Note that some types
|
|
of blades don't support floppy disk drive. It is recommended that all
|
|
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
|
|
If there is any duplication of the configured boot sequence and the
|
|
current configuration, the two boot sequence will be swapped.
|
|
For an example: the current boot sequence is
|
|
1=HD0, 2=CD, 3=FD, 4=HD1
|
|
If the user wants to configure 1=FD which is a duplication of 3 then the
|
|
new boot sequence will be:
|
|
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)"
|
|
::= { bladeBootSequenceEntry 8 }
|
|
|
|
bootSequence3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noneSpecified(0),
|
|
floppy(1),
|
|
cdrom(2),
|
|
hardDrive0(3),
|
|
hardDrive1(4),
|
|
hardDrive2(5),
|
|
hardDrive3(6),
|
|
networkBoot(7),
|
|
notAvailable(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The boot device for this blade boot sequence. Note that some types
|
|
of blades don't support floppy disk drive. It is recommended that all
|
|
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
|
|
If there is any duplication of the configured boot sequence and the
|
|
current configuration, the two boot sequence will be swapped.
|
|
For an example: the current boot sequence is
|
|
1=HD0, 2=CD, 3=FD, 4=HD1
|
|
If the user wants to configure 1=FD which is a duplication of 3 then the
|
|
new boot sequence will be:
|
|
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)"
|
|
::= { bladeBootSequenceEntry 9 }
|
|
|
|
bootSequence4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noneSpecified(0),
|
|
floppy(1),
|
|
cdrom(2),
|
|
hardDrive0(3),
|
|
hardDrive1(4),
|
|
hardDrive2(5),
|
|
hardDrive3(6),
|
|
networkBoot(7),
|
|
notAvailable(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The boot device for this blade boot sequence. Note that some types
|
|
of blades don't support floppy disk drive. It is recommended that all
|
|
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
|
|
If there is any duplication of the configured boot sequence and the
|
|
current configuration, the two boot sequence will be swapped.
|
|
For an example: the current boot sequence is
|
|
1=HD0, 2=CD, 3=FD, 4=HD1
|
|
If the user wants to configure 1=FD which is a duplication of 3 then the
|
|
new boot sequence will be:
|
|
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)"
|
|
::= { bladeBootSequenceEntry 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade local control
|
|
-- ********************************************************************************
|
|
-- 22.1.4
|
|
bladeRemoteControl OBJECT IDENTIFIER ::= { processorBlade 4 }
|
|
-- remote blade control
|
|
|
|
bladeRemoteControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeRemoteControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade remote power control information.
|
|
Contains power on/off enablement status for each blade."
|
|
::= { bladeRemoteControl 1 }
|
|
|
|
bladeRemoteControlEntry OBJECT-TYPE
|
|
SYNTAX BladeRemoteControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote power control entry"
|
|
INDEX { remoteControlIndex }
|
|
::= { bladeRemoteControlTable 1 }
|
|
|
|
|
|
BladeRemoteControlEntry ::= SEQUENCE {
|
|
remoteControlIndex INTEGER,
|
|
remoteControlBladeId INTEGER,
|
|
remoteControlBladeExists INTEGER,
|
|
remoteControlBladePowerState INTEGER,
|
|
remoteControlBladeHealthState INTEGER,
|
|
remoteControlBladeName OCTET STRING,
|
|
remotePowerControlEnable INTEGER,
|
|
remoteMediaTrayControlEnable INTEGER,
|
|
remoteKVMControlEnable INTEGER,
|
|
remoteWakeOnLanControlEnable INTEGER
|
|
}
|
|
|
|
remoteControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade remote power control index."
|
|
::= { bladeRemoteControlEntry 1 }
|
|
|
|
|
|
remoteControlBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeRemoteControlEntry 2 }
|
|
|
|
remoteControlBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeRemoteControlEntry 3 }
|
|
|
|
remoteControlBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power state for blade server.
|
|
0 = off, 1 = on, 255 = unknown."
|
|
::= { bladeRemoteControlEntry 4 }
|
|
|
|
remoteControlBladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3),
|
|
kernel(4),
|
|
init(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade server.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad, 4 = kernel mode, 5 = discovering"
|
|
::= { bladeRemoteControlEntry 5 }
|
|
|
|
remoteControlBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeRemoteControlEntry 6 }
|
|
|
|
-- 22.1.4.1
|
|
remotePowerControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade remote power control enablement status."
|
|
::= { bladeRemoteControlEntry 7 }
|
|
|
|
-- 22.1.4.2
|
|
remoteMediaTrayControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade media tray enablement status."
|
|
::= { bladeRemoteControlEntry 8 }
|
|
|
|
|
|
-- 22.1.4.3
|
|
remoteKVMControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade KVM enablement status. Note that some types of blades
|
|
don't support KVM"
|
|
::= { bladeRemoteControlEntry 9 }
|
|
|
|
-- 22.1.4.4
|
|
remoteWakeOnLanControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Wake On Lan enablement status."
|
|
::= { bladeRemoteControlEntry 10 }
|
|
|
|
|
|
bladePolicy OBJECT IDENTIFIER ::= { bladeRemoteControl 2}
|
|
-- global blade remote control policy
|
|
|
|
-- 22.1.4.1
|
|
bladePolicyPowerControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade remote power control enablement status policy.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePolicy 1 }
|
|
|
|
-- 22.1.4.2
|
|
bladePolicyMediaTrayControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade media tray enablement status policy.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePolicy 2 }
|
|
|
|
|
|
-- 22.1.4.3
|
|
bladePolicyKVMControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade KVM enablement status policy. Note that some types of blades
|
|
don't support KVM.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for
|
|
this MIB."
|
|
::= { bladePolicy 3 }
|
|
|
|
-- 22.1.4.4
|
|
bladePolicyWakeOnLanControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Wake On Lan enablement status policy.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePolicy 4 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Blade system health state params
|
|
-- ********************************************************************************
|
|
|
|
|
|
-- 22.1.5
|
|
-- rename this to blade health?
|
|
bladeMonitors OBJECT IDENTIFIER ::= { processorBlade 5 }
|
|
|
|
-- 22.1.5.1
|
|
bladeSystemStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeSystemStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade status information."
|
|
::= { bladeMonitors 1 }
|
|
|
|
bladeSystemStatusEntry OBJECT-TYPE
|
|
SYNTAX BladeSystemStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade system status entry"
|
|
INDEX { bladeStatusIndex }
|
|
::= { bladeSystemStatusTable 1 }
|
|
|
|
|
|
BladeSystemStatusEntry ::= SEQUENCE {
|
|
bladeStatusIndex INTEGER,
|
|
bladeId INTEGER,
|
|
bladeExists INTEGER,
|
|
bladePowerState INTEGER,
|
|
bladeHealthState INTEGER,
|
|
bladeName OCTET STRING,
|
|
bladeRemotePowerEnable INTEGER,
|
|
bladeRemoteMediaTrayEnable INTEGER,
|
|
bladeRemoteKVMEnable INTEGER,
|
|
bladeConnectionType INTEGER,
|
|
bladeOwnsKVM INTEGER,
|
|
bladeOwnsMediaTray INTEGER,
|
|
bladeRemoteWakeOnLanEnable INTEGER,
|
|
bladeServerExpansion INTEGER,
|
|
bladeWidth INTEGER,
|
|
bladeSupportCapacityOnDemand INTEGER
|
|
}
|
|
|
|
|
|
bladeStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade system status index."
|
|
::= { bladeSystemStatusEntry 1 }
|
|
|
|
bladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeSystemStatusEntry 2 }
|
|
|
|
bladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeSystemStatusEntry 3 }
|
|
|
|
bladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeSystemStatusEntry 4 }
|
|
|
|
bladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade server.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad."
|
|
::= { bladeSystemStatusEntry 5 }
|
|
|
|
bladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeSystemStatusEntry 6 }
|
|
|
|
bladeRemotePowerEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote power state for the blade server.
|
|
0x01 indicates enabled."
|
|
::= { bladeSystemStatusEntry 7 }
|
|
|
|
bladeRemoteMediaTrayEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote Media Tray state for the blade server.
|
|
0x01 indicates enabled."
|
|
::= { bladeSystemStatusEntry 8 }
|
|
|
|
bladeRemoteKVMEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote keyboard/video/monitor state for the blade server.
|
|
0x01 indicates enabled. Note that some types of blades
|
|
don't support KVM"
|
|
::= { bladeSystemStatusEntry 9 }
|
|
|
|
bladeConnectionType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ethernet(1),
|
|
fiber(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection type for the blade server.
|
|
0 = none, 1 = ethernet, 2 = fiber"
|
|
::= { bladeSystemStatusEntry 10 }
|
|
|
|
bladeOwnsKVM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the MM owns the KVM.
|
|
0 = false, 1 = true. Note that some types of blades
|
|
don't support KVM"
|
|
::= { bladeSystemStatusEntry 11 }
|
|
|
|
bladeOwnsMediaTray OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade owns the Media Tray.
|
|
0 = false, 1 = true."
|
|
::= { bladeSystemStatusEntry 12 }
|
|
|
|
bladeRemoteWakeOnLanEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote wake on LAN state for the blade server.
|
|
0x01 indicates enabled."
|
|
::= { bladeSystemStatusEntry 13 }
|
|
|
|
bladeServerExpansion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This shows whether this blade server has a blade server expansion attached.
|
|
A yes column indicates that a blade storage expansion is installed for this
|
|
blade server."
|
|
::= { bladeSystemStatusEntry 14 }
|
|
|
|
bladeWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the blade including any supplement blade attached to it"
|
|
::= { bladeSystemStatusEntry 15 }
|
|
|
|
bladeSupportCapacityOnDemand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This shows whether this blade server support Capacity On Demand."
|
|
::= { bladeSystemStatusEntry 16 }
|
|
|
|
-- 22.1.5.2
|
|
bladeHealthSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade health summary information.
|
|
Contains information about the overall blade health status."
|
|
::= { bladeMonitors 2 }
|
|
|
|
bladeHealthSummaryEntry OBJECT-TYPE
|
|
SYNTAX BladeHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade health summary entry"
|
|
INDEX { bladeHealthSummaryIndex }
|
|
::= { bladeHealthSummaryTable 1 }
|
|
|
|
|
|
BladeHealthSummaryEntry ::= SEQUENCE {
|
|
bladeHealthSummaryIndex INTEGER,
|
|
bladeHealthSummaryBladeId INTEGER,
|
|
bladeHealthSummarySeverity OCTET STRING,
|
|
bladeHealthSummaryDescription OCTET STRING
|
|
}
|
|
|
|
|
|
bladeHealthSummaryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade health summary index."
|
|
::= { bladeHealthSummaryEntry 1 }
|
|
|
|
bladeHealthSummaryBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeHealthSummaryEntry 2 }
|
|
|
|
bladeHealthSummarySeverity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary severity."
|
|
::= { bladeHealthSummaryEntry 3 }
|
|
|
|
bladeHealthSummaryDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary description."
|
|
::= { bladeHealthSummaryEntry 4 }
|
|
|
|
|
|
|
|
bladeTemperaturesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeTemperaturesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade temperatures information."
|
|
::= { bladeMonitors 3 }
|
|
|
|
bladeTemperaturesEntry OBJECT-TYPE
|
|
SYNTAX BladeTemperaturesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade temperatures table entry"
|
|
INDEX { temperatureIndex }
|
|
::= { bladeTemperaturesTable 1 }
|
|
|
|
|
|
BladeTemperaturesEntry ::= SEQUENCE {
|
|
temperatureIndex INTEGER,
|
|
temperatureBladeId INTEGER,
|
|
temperatureBladeExists INTEGER,
|
|
temperatureBladePowerState INTEGER,
|
|
temperatureBladeName OCTET STRING,
|
|
temperatureCPU1 OCTET STRING,
|
|
temperatureCPU2 OCTET STRING,
|
|
temperatureCPU3 OCTET STRING,
|
|
temperatureCPU4 OCTET STRING,
|
|
temperatureDASD1 OCTET STRING,
|
|
bladeSensorTempCapability INTEGER,
|
|
bladeSensor1Temp OCTET STRING,
|
|
bladeSensor2Temp OCTET STRING,
|
|
bladeSensor3Temp OCTET STRING,
|
|
bladeSensor4Temp OCTET STRING,
|
|
bladeSensor5Temp OCTET STRING,
|
|
bladeSensor6Temp OCTET STRING
|
|
|
|
}
|
|
|
|
temperatureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade temperatures table index."
|
|
::= { bladeTemperaturesEntry 1 }
|
|
|
|
|
|
temperatureBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeTemperaturesEntry 2 }
|
|
|
|
temperatureBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeTemperaturesEntry 3 }
|
|
|
|
temperatureBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeTemperaturesEntry 4 }
|
|
|
|
temperatureBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeTemperaturesEntry 5 }
|
|
|
|
temperatureCPU1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 6 }
|
|
|
|
temperatureCPU2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 7 }
|
|
|
|
temperatureCPU3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 8 }
|
|
|
|
temperatureCPU4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 9 }
|
|
|
|
temperatureDASD1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade DASD temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 10 }
|
|
|
|
bladeSensorTempCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade is IPMI capable or not."
|
|
::= { bladeTemperaturesEntry 11 }
|
|
|
|
bladeSensor1Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 12 }
|
|
|
|
bladeSensor2Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 13 }
|
|
|
|
bladeSensor3Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 14 }
|
|
|
|
bladeSensor4Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 15 }
|
|
|
|
bladeSensor5Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 16 }
|
|
|
|
bladeSensor6Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 17 }
|
|
|
|
bladeTemperatureThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeTemperatureThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade temperature thresholds information."
|
|
::= { bladeMonitors 4 }
|
|
|
|
bladeTemperatureThresholdsEntry OBJECT-TYPE
|
|
SYNTAX BladeTemperatureThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade temperature thresholds table entry"
|
|
INDEX { temperatureThresholdIndex }
|
|
::= { bladeTemperatureThresholdsTable 1 }
|
|
|
|
|
|
BladeTemperatureThresholdsEntry ::= SEQUENCE {
|
|
temperatureThresholdIndex INTEGER,
|
|
temperatureThresholdBladeId INTEGER,
|
|
temperatureThresholdBladeExists INTEGER,
|
|
temperatureThresholdBladePowerState INTEGER,
|
|
temperatureThresholdBladeName OCTET STRING,
|
|
temperatureCPU1HardShutdown OCTET STRING,
|
|
temperatureCPU1Warning OCTET STRING,
|
|
temperatureCPU1WarningReset OCTET STRING,
|
|
temperatureCPU2HardShutdown OCTET STRING,
|
|
temperatureCPU2Warning OCTET STRING,
|
|
temperatureCPU2WarningReset OCTET STRING,
|
|
temperatureCPU3HardShutdown OCTET STRING,
|
|
temperatureCPU3Warning OCTET STRING,
|
|
temperatureCPU3WarningReset OCTET STRING,
|
|
temperatureCPU4HardShutdown OCTET STRING,
|
|
temperatureCPU4Warning OCTET STRING,
|
|
temperatureCPU4WarningReset OCTET STRING,
|
|
temperatureDASD1HardShutdown OCTET STRING,
|
|
temperatureDASD1Warning OCTET STRING,
|
|
temperatureDASD1WarningReset OCTET STRING,
|
|
bladeTempThresholdSensorCapability INTEGER,
|
|
temperatureSensor1HardShutdown OCTET STRING,
|
|
temperatureSensor1Warning OCTET STRING,
|
|
temperatureSensor1WarningReset OCTET STRING,
|
|
temperatureSensor2HardShutdown OCTET STRING,
|
|
temperatureSensor2Warning OCTET STRING,
|
|
temperatureSensor2WarningReset OCTET STRING,
|
|
temperatureSensor3HardShutdown OCTET STRING,
|
|
temperatureSensor3Warning OCTET STRING,
|
|
temperatureSensor3WarningReset OCTET STRING,
|
|
temperatureSensor4HardShutdown OCTET STRING,
|
|
temperatureSensor4Warning OCTET STRING,
|
|
temperatureSensor4WarningReset OCTET STRING,
|
|
temperatureSensor5HardShutdown OCTET STRING,
|
|
temperatureSensor5Warning OCTET STRING,
|
|
temperatureSensor5WarningReset OCTET STRING,
|
|
temperatureSensor6HardShutdown OCTET STRING,
|
|
temperatureSensor6Warning OCTET STRING,
|
|
temperatureSensor6WarningReset OCTET STRING
|
|
}
|
|
|
|
temperatureThresholdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade temperature threshold table index."
|
|
::= { bladeTemperatureThresholdsEntry 1 }
|
|
|
|
|
|
temperatureThresholdBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeTemperatureThresholdsEntry 2 }
|
|
|
|
temperatureThresholdBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeTemperatureThresholdsEntry 3 }
|
|
|
|
temperatureThresholdBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeTemperatureThresholdsEntry 4 }
|
|
|
|
temperatureThresholdBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeTemperatureThresholdsEntry 5 }
|
|
|
|
temperatureCPU1HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU hard shutdown temperature in degrees
|
|
centigrade(C). If the component's temperature rises above
|
|
this value the system will be powered off immediately.
|
|
If enabled, a critical alert/event will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 6 }
|
|
|
|
temperatureCPU1Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning temperature in degrees centigrade(C).
|
|
If the temperature rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 7 }
|
|
|
|
temperatureCPU1WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning reset temperature in degrees
|
|
centigrade(C). If the temperature rises above this value and
|
|
if a warning alert/event had previously been created then the
|
|
alert/event will be reset.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 8 }
|
|
|
|
temperatureCPU2HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU hard shutdown temperature in degrees
|
|
centigrade(C). If the component's temperature rises above
|
|
this value the system will be powered off immediately.
|
|
If enabled, a critical alert/event will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 9 }
|
|
|
|
temperatureCPU2Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning temperature in degrees centigrade(C).
|
|
If the temperature rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 10 }
|
|
|
|
temperatureCPU2WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning reset temperature in degrees
|
|
centigrade(C). If the temperature rises above this value and
|
|
if a warning alert/event had previously been created then the
|
|
alert/event will be reset.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 11 }
|
|
|
|
temperatureCPU3HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU hard shutdown temperature in degrees
|
|
centigrade(C). If the component's temperature rises above
|
|
this value the system will be powered off immediately.
|
|
If enabled, a critical alert/event will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 12 }
|
|
|
|
temperatureCPU3Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning temperature in degrees centigrade(C).
|
|
If the temperature rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 13 }
|
|
|
|
temperatureCPU3WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning reset temperature in degrees
|
|
centigrade(C). If the temperature rises above this value and
|
|
if a warning alert/event had previously been created then the
|
|
alert/event will be reset.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 14 }
|
|
|
|
temperatureCPU4HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU hard shutdown temperature in degrees
|
|
centigrade(C). If the component's temperature rises above
|
|
this value the system will be powered off immediately.
|
|
If enabled, a critical alert/event will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 15 }
|
|
|
|
temperatureCPU4Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning temperature in degrees centigrade(C).
|
|
If the temperature rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 16 }
|
|
|
|
temperatureCPU4WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning reset temperature in degrees
|
|
centigrade(C). If the temperature rises above this value and
|
|
if a warning alert/event had previously been created then the
|
|
alert/event will be reset.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 17 }
|
|
|
|
temperatureDASD1HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade DASD hard shutdown temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 18 }
|
|
|
|
temperatureDASD1Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade DASD warning temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 19 }
|
|
|
|
temperatureDASD1WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade DASD warning reset temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 20 }
|
|
|
|
bladeTempThresholdSensorCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade is IPMI capable or not."
|
|
::= { bladeTemperatureThresholdsEntry 21 }
|
|
|
|
temperatureSensor1HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 22 }
|
|
|
|
temperatureSensor1Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 23 }
|
|
|
|
temperatureSensor1WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 24 }
|
|
|
|
temperatureSensor2HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 25 }
|
|
|
|
temperatureSensor2Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 26 }
|
|
|
|
temperatureSensor2WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 27 }
|
|
|
|
temperatureSensor3HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 28 }
|
|
|
|
temperatureSensor3Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 29 }
|
|
|
|
temperatureSensor3WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 30 }
|
|
|
|
temperatureSensor4HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 31 }
|
|
|
|
temperatureSensor4Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 32 }
|
|
|
|
temperatureSensor4WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 33 }
|
|
|
|
temperatureSensor5HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 34 }
|
|
|
|
temperatureSensor5Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 35 }
|
|
|
|
temperatureSensor5WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 36 }
|
|
|
|
temperatureSensor6HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 37 }
|
|
|
|
temperatureSensor6Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 38 }
|
|
|
|
temperatureSensor6WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 39 }
|
|
|
|
|
|
|
|
bladeVoltagesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeVoltagesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade voltages information."
|
|
::= { bladeMonitors 5 }
|
|
|
|
bladeVoltagesEntry OBJECT-TYPE
|
|
SYNTAX BladeVoltagesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade voltages table entry"
|
|
INDEX { voltageIndex }
|
|
::= { bladeVoltagesTable 1 }
|
|
|
|
BladeVoltagesEntry ::= SEQUENCE {
|
|
voltageIndex INTEGER,
|
|
voltageBladeId INTEGER,
|
|
voltageBladeExists INTEGER,
|
|
voltageBladePowerState INTEGER,
|
|
voltageBladeName OCTET STRING,
|
|
-- voltageBladeName OCTET STRING,
|
|
bladePlus5Volt OCTET STRING,
|
|
bladePlus3pt3Volt OCTET STRING,
|
|
bladePlus12Volt OCTET STRING,
|
|
-- bladeMinus12Volt OCTET STRING,
|
|
bladePlus2pt5Volt OCTET STRING,
|
|
bladePlus1pt5Volt OCTET STRING,
|
|
bladePlus1pt25Volt OCTET STRING,
|
|
bladeVRM1Volt OCTET STRING,
|
|
bladeSensorVoltCapability INTEGER,
|
|
bladeSensor1Volt OCTET STRING,
|
|
bladeSensor2Volt OCTET STRING,
|
|
bladeSensor3Volt OCTET STRING,
|
|
bladeSensor4Volt OCTET STRING,
|
|
bladeSensor5Volt OCTET STRING,
|
|
bladeSensor6Volt OCTET STRING,
|
|
bladeSensor7Volt OCTET STRING,
|
|
bladeSensor8Volt OCTET STRING,
|
|
bladeSensor9Volt OCTET STRING,
|
|
bladeSensor10Volt OCTET STRING,
|
|
bladeSensor11Volt OCTET STRING,
|
|
bladeSensor12Volt OCTET STRING,
|
|
bladeSensor13Volt OCTET STRING,
|
|
bladeSensor14Volt OCTET STRING,
|
|
bladeSensor15Volt OCTET STRING,
|
|
bladeSensor16Volt OCTET STRING,
|
|
bladeSensor17Volt OCTET STRING,
|
|
bladeSensor18Volt OCTET STRING,
|
|
bladeSensor19Volt OCTET STRING,
|
|
bladeSensor20Volt OCTET STRING,
|
|
bladeSensor21Volt OCTET STRING,
|
|
bladeSensor22Volt OCTET STRING,
|
|
bladeSensor23Volt OCTET STRING,
|
|
bladeSensor24Volt OCTET STRING,
|
|
bladeSensor25Volt OCTET STRING,
|
|
bladeSensor26Volt OCTET STRING,
|
|
bladeSensor27Volt OCTET STRING,
|
|
bladeSensor28Volt OCTET STRING,
|
|
bladeSensor29Volt OCTET STRING,
|
|
bladeSensor30Volt OCTET STRING
|
|
}
|
|
|
|
voltageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade voltages table index."
|
|
::= { bladeVoltagesEntry 1 }
|
|
|
|
|
|
voltageBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeVoltagesEntry 2 }
|
|
|
|
voltageBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeVoltagesEntry 3 }
|
|
|
|
voltageBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeVoltagesEntry 4 }
|
|
|
|
voltageBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeVoltagesEntry 5 }
|
|
|
|
bladePlus5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+5 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 6 }
|
|
|
|
bladePlus3pt3Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+3.3 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 7 }
|
|
|
|
bladePlus12Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+12 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 8 }
|
|
|
|
-- bladeMinus12Volt OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "-12 Volt power supply voltage reading for the blade
|
|
-- expressed in Volts(V). An octet string expressed as
|
|
-- 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { bladeVoltagesEntry 9 }
|
|
|
|
bladePlus2pt5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+2.5 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 10 }
|
|
|
|
bladePlus1pt5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+1.5 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 11 }
|
|
|
|
bladePlus1pt25Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+1.25 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 12 }
|
|
|
|
bladeVRM1Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"VRM 1 voltage reading for the blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 13 }
|
|
|
|
bladeSensorVoltCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade is IPMI capable or not."
|
|
::= { bladeVoltagesEntry 14 }
|
|
|
|
bladeSensor1Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 15 }
|
|
|
|
bladeSensor2Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 16 }
|
|
|
|
bladeSensor3Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 17 }
|
|
|
|
bladeSensor4Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 18 }
|
|
|
|
bladeSensor5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 19 }
|
|
|
|
bladeSensor6Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 20 }
|
|
|
|
bladeSensor7Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 21 }
|
|
|
|
bladeSensor8Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 22 }
|
|
|
|
bladeSensor9Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 23 }
|
|
|
|
bladeSensor10Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 24 }
|
|
|
|
bladeSensor11Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 25 }
|
|
|
|
bladeSensor12Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 26 }
|
|
|
|
bladeSensor13Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 27 }
|
|
|
|
bladeSensor14Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 28 }
|
|
|
|
bladeSensor15Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 29 }
|
|
|
|
bladeSensor16Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 30 }
|
|
|
|
bladeSensor17Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 31 }
|
|
|
|
bladeSensor18Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 32 }
|
|
|
|
bladeSensor19Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 33 }
|
|
|
|
bladeSensor20Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 34 }
|
|
|
|
bladeSensor21Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 35 }
|
|
|
|
bladeSensor22Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 36 }
|
|
|
|
bladeSensor23Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 37 }
|
|
|
|
bladeSensor24Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 38 }
|
|
|
|
bladeSensor25Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 39 }
|
|
|
|
bladeSensor26Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 40 }
|
|
|
|
bladeSensor27Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 41 }
|
|
|
|
|
|
bladeSensor28Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 42 }
|
|
|
|
bladeSensor29Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 43 }
|
|
|
|
bladeSensor30Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 44 }
|
|
|
|
|
|
bladeVoltageThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeVoltageThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade VoltageThresholds information."
|
|
::= { bladeMonitors 6 }
|
|
|
|
|
|
bladeVoltageThresholdsEntry OBJECT-TYPE
|
|
SYNTAX BladeVoltageThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade voltage thresholds table entry"
|
|
INDEX { voltageThresholdIndex }
|
|
::= { bladeVoltageThresholdsTable 1 }
|
|
|
|
|
|
BladeVoltageThresholdsEntry ::= SEQUENCE {
|
|
voltageThresholdIndex INTEGER,
|
|
voltageThresholdBladeId INTEGER,
|
|
voltageThresholdBladeExists INTEGER,
|
|
voltageThresholdBladePowerState INTEGER,
|
|
voltageThresholdBladeName OCTET STRING,
|
|
bladePlus5VoltHighWarning OCTET STRING,
|
|
bladePlus5VoltLowWarning OCTET STRING,
|
|
bladePlus3pt3VoltHighWarning OCTET STRING,
|
|
bladePlus3pt3VoltLowWarning OCTET STRING,
|
|
bladePlus12VoltHighWarning OCTET STRING,
|
|
bladePlus12VoltLowWarning OCTET STRING,
|
|
-- bladeMinus12VoltHighWarning OCTET STRING,
|
|
-- bladeMinus12VoltLowWarning OCTET STRING,
|
|
bladePlus2pt5VoltHighWarning OCTET STRING,
|
|
bladePlus2pt5VoltLowWarning OCTET STRING,
|
|
bladePlus1pt5VoltHighWarning OCTET STRING,
|
|
bladePlus1pt5VoltLowWarning OCTET STRING,
|
|
bladePlus1pt25VoltHighWarning OCTET STRING,
|
|
bladePlus1pt25VoltLowWarning OCTET STRING,
|
|
-- bladeVRM1VoltHighWarning OCTET STRING,
|
|
-- bladeVRM1VoltLowWarning OCTET STRING,
|
|
bladeVoltThresholdSensorCapability INTEGER,
|
|
bladeSensor1VoltHighWarning OCTET STRING,
|
|
bladeSensor1VoltLowWarning OCTET STRING,
|
|
bladeSensor2VoltHighWarning OCTET STRING,
|
|
bladeSensor2VoltLowWarning OCTET STRING,
|
|
bladeSensor3VoltHighWarning OCTET STRING,
|
|
bladeSensor3VoltLowWarning OCTET STRING,
|
|
bladeSensor4VoltHighWarning OCTET STRING,
|
|
bladeSensor4VoltLowWarning OCTET STRING,
|
|
bladeSensor5VoltHighWarning OCTET STRING,
|
|
bladeSensor5VoltLowWarning OCTET STRING,
|
|
bladeSensor6VoltHighWarning OCTET STRING,
|
|
bladeSensor6VoltLowWarning OCTET STRING,
|
|
bladeSensor7VoltHighWarning OCTET STRING,
|
|
bladeSensor7VoltLowWarning OCTET STRING,
|
|
bladeSensor8VoltHighWarning OCTET STRING,
|
|
bladeSensor8VoltLowWarning OCTET STRING,
|
|
bladeSensor9VoltHighWarning OCTET STRING,
|
|
bladeSensor9VoltLowWarning OCTET STRING,
|
|
bladeSensor10VoltHighWarning OCTET STRING,
|
|
bladeSensor10VoltLowWarning OCTET STRING,
|
|
bladeSensor11VoltHighWarning OCTET STRING,
|
|
bladeSensor11VoltLowWarning OCTET STRING,
|
|
bladeSensor12VoltHighWarning OCTET STRING,
|
|
bladeSensor12VoltLowWarning OCTET STRING,
|
|
bladeSensor13VoltHighWarning OCTET STRING,
|
|
bladeSensor13VoltLowWarning OCTET STRING,
|
|
bladeSensor14VoltHighWarning OCTET STRING,
|
|
bladeSensor14VoltLowWarning OCTET STRING,
|
|
bladeSensor15VoltHighWarning OCTET STRING,
|
|
bladeSensor15VoltLowWarning OCTET STRING,
|
|
bladeSensor16VoltHighWarning OCTET STRING,
|
|
bladeSensor16VoltLowWarning OCTET STRING,
|
|
bladeSensor17VoltHighWarning OCTET STRING,
|
|
bladeSensor17VoltLowWarning OCTET STRING,
|
|
bladeSensor18VoltHighWarning OCTET STRING,
|
|
bladeSensor18VoltLowWarning OCTET STRING,
|
|
bladeSensor19VoltHighWarning OCTET STRING,
|
|
bladeSensor19VoltLowWarning OCTET STRING,
|
|
bladeSensor20VoltHighWarning OCTET STRING,
|
|
bladeSensor20VoltLowWarning OCTET STRING,
|
|
bladeSensor21VoltHighWarning OCTET STRING,
|
|
bladeSensor21VoltLowWarning OCTET STRING,
|
|
bladeSensor22VoltHighWarning OCTET STRING,
|
|
bladeSensor22VoltLowWarning OCTET STRING,
|
|
bladeSensor23VoltHighWarning OCTET STRING,
|
|
bladeSensor23VoltLowWarning OCTET STRING,
|
|
bladeSensor24VoltHighWarning OCTET STRING,
|
|
bladeSensor24VoltLowWarning OCTET STRING,
|
|
bladeSensor25VoltHighWarning OCTET STRING,
|
|
bladeSensor25VoltLowWarning OCTET STRING,
|
|
bladeSensor26VoltHighWarning OCTET STRING,
|
|
bladeSensor26VoltLowWarning OCTET STRING,
|
|
bladeSensor27VoltHighWarning OCTET STRING,
|
|
bladeSensor27VoltLowWarning OCTET STRING,
|
|
bladeSensor28VoltHighWarning OCTET STRING,
|
|
bladeSensor28VoltLowWarning OCTET STRING,
|
|
bladeSensor29VoltHighWarning OCTET STRING,
|
|
bladeSensor29VoltLowWarning OCTET STRING,
|
|
bladeSensor30VoltHighWarning OCTET STRING,
|
|
bladeSensor30VoltLowWarning OCTET STRING
|
|
}
|
|
|
|
voltageThresholdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade voltage thresholds table index."
|
|
::= { bladeVoltageThresholdsEntry 1 }
|
|
|
|
|
|
voltageThresholdBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeVoltageThresholdsEntry 2 }
|
|
|
|
voltageThresholdBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeVoltageThresholdsEntry 3 }
|
|
|
|
voltageThresholdBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeVoltageThresholdsEntry 4 }
|
|
|
|
voltageThresholdBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeVoltageThresholdsEntry 5 }
|
|
|
|
bladePlus5VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 6 }
|
|
|
|
bladePlus5VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 7 }
|
|
|
|
bladePlus3pt3VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 8 }
|
|
|
|
bladePlus3pt3VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 9 }
|
|
|
|
bladePlus12VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 10 }
|
|
|
|
bladePlus12VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 11 }
|
|
|
|
-- bladeMinus12VoltHighWarning OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Voltage warning threshold reading expressed in Volts(V).
|
|
-- If the voltage rises above this value a warning alert/event
|
|
-- if enabled will be generated.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { bladeVoltageThresholdsEntry 12 }
|
|
--
|
|
-- bladeMinus12VoltLowWarning OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Voltage warning threshold reading expressed in Volts(V).
|
|
-- If the voltage drops below this value a warning alert/event
|
|
-- if enabled will be generated.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { bladeVoltageThresholdsEntry 13 }
|
|
|
|
bladePlus2pt5VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 14 }
|
|
|
|
bladePlus2pt5VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 15 }
|
|
|
|
bladePlus1pt5VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 16 }
|
|
|
|
bladePlus1pt5VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 17 }
|
|
|
|
bladePlus1pt25VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 18 }
|
|
|
|
bladePlus1pt25VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 19 }
|
|
|
|
-- bladeVRM1VoltHighWarning OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The value for the VRM1 voltage."
|
|
-- "Voltage warning threshold reading expressed in Volts(V).
|
|
-- If the voltage rises above this value a warning alert/event
|
|
-- if enabled will be generated.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { bladeVoltageThresholdsEntry 20 }
|
|
--
|
|
-- bladeVRM1VoltLowWarning OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The value for the VRM1 voltage."
|
|
-- "Voltage warning threshold reading expressed in Volts(V).
|
|
-- If the voltage drops below this value a warning alert/event
|
|
-- if enabled will be generated.
|
|
-- An octet string expressed as 'sdd.dd Volts' where:
|
|
-- s is the sign ('-' for negative or '+' for positive)
|
|
-- d is a decimal digit or blank space for a leading zero.
|
|
-- The string 'Not Readable!' indicates that the given monitor
|
|
-- is not supported on this system."
|
|
-- ::= { bladeVoltageThresholdsEntry 21 }
|
|
|
|
bladeVoltThresholdSensorCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade is IPMI capable or not."
|
|
::= { bladeVoltageThresholdsEntry 22 }
|
|
|
|
bladeSensor1VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 23 }
|
|
|
|
bladeSensor1VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 24 }
|
|
|
|
bladeSensor2VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 25 }
|
|
|
|
bladeSensor2VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 26 }
|
|
|
|
bladeSensor3VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 27 }
|
|
|
|
bladeSensor3VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 28 }
|
|
|
|
bladeSensor4VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 29 }
|
|
|
|
bladeSensor4VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 30 }
|
|
|
|
bladeSensor5VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 31 }
|
|
|
|
bladeSensor5VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 32 }
|
|
|
|
bladeSensor6VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 33 }
|
|
|
|
bladeSensor6VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 34 }
|
|
|
|
bladeSensor7VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 35 }
|
|
|
|
bladeSensor7VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 36 }
|
|
|
|
bladeSensor8VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 37 }
|
|
|
|
bladeSensor8VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 38 }
|
|
|
|
bladeSensor9VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 39 }
|
|
|
|
bladeSensor9VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 40 }
|
|
|
|
bladeSensor10VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 41 }
|
|
|
|
bladeSensor10VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 42 }
|
|
|
|
bladeSensor11VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 43 }
|
|
|
|
bladeSensor11VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 44 }
|
|
|
|
bladeSensor12VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 45 }
|
|
|
|
bladeSensor12VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 46 }
|
|
|
|
bladeSensor13VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 47 }
|
|
|
|
bladeSensor13VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 48 }
|
|
|
|
bladeSensor14VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 49 }
|
|
|
|
bladeSensor14VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 50 }
|
|
|
|
bladeSensor15VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 51 }
|
|
|
|
bladeSensor15VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 52 }
|
|
|
|
bladeSensor16VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 53 }
|
|
|
|
bladeSensor16VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 54 }
|
|
|
|
bladeSensor17VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 55 }
|
|
|
|
bladeSensor17VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 56 }
|
|
|
|
bladeSensor18VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 57 }
|
|
|
|
bladeSensor18VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 58 }
|
|
|
|
bladeSensor19VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 59 }
|
|
|
|
bladeSensor19VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 60 }
|
|
|
|
bladeSensor20VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 61 }
|
|
|
|
bladeSensor20VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 62 }
|
|
|
|
bladeSensor21VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 63 }
|
|
|
|
bladeSensor21VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 64 }
|
|
|
|
bladeSensor22VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 65 }
|
|
|
|
bladeSensor22VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 66 }
|
|
|
|
bladeSensor23VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 67 }
|
|
|
|
bladeSensor23VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 68 }
|
|
|
|
bladeSensor24VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 69 }
|
|
|
|
bladeSensor24VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 70 }
|
|
|
|
bladeSensor25VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 71 }
|
|
|
|
bladeSensor25VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 72 }
|
|
|
|
bladeSensor26VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 73 }
|
|
|
|
bladeSensor26VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 74 }
|
|
|
|
bladeSensor27VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 75 }
|
|
|
|
bladeSensor27VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 76 }
|
|
|
|
bladeSensor28VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 77 }
|
|
|
|
bladeSensor28VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 78 }
|
|
|
|
bladeSensor29VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 79 }
|
|
|
|
bladeSensor29VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 80 }
|
|
|
|
bladeSensor30VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 81 }
|
|
|
|
bladeSensor30VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 82 }
|
|
|
|
bladePowerRestart OBJECT IDENTIFIER ::= { processorBlade 6 }
|
|
-- blade power/restart control
|
|
|
|
bladePowerRestartTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladePowerRestartEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade remote power control information.
|
|
Contains power on/off enablement status for each blade."
|
|
::= { bladePowerRestart 1 }
|
|
|
|
bladePowerRestartEntry OBJECT-TYPE
|
|
SYNTAX BladePowerRestartEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade power restart table entry"
|
|
INDEX { powerRestartIndex }
|
|
::= { bladePowerRestartTable 1 }
|
|
|
|
|
|
BladePowerRestartEntry ::= SEQUENCE {
|
|
powerRestartIndex INTEGER,
|
|
powerRestartBladeId INTEGER,
|
|
powerRestartBladeExists INTEGER,
|
|
powerRestartBladePowerState INTEGER,
|
|
powerRestartBladeHealthState INTEGER,
|
|
powerRestartBladeName OCTET STRING,
|
|
powerOnOffBlade INTEGER,
|
|
restartBlade INTEGER,
|
|
restartBladeSMP INTEGER,
|
|
restartBladeNMI INTEGER,
|
|
restartBladeClearNVRAM INTEGER,
|
|
restartBladeInvokeDiags INTEGER,
|
|
restartBladeInvokeDiagsFromDefaultBootList INTEGER
|
|
}
|
|
|
|
powerRestartIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade power restart table index."
|
|
::= { bladePowerRestartEntry 1 }
|
|
|
|
|
|
powerRestartBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladePowerRestartEntry 2 }
|
|
|
|
powerRestartBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladePowerRestartEntry 3 }
|
|
|
|
powerRestartBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladePowerRestartEntry 4 }
|
|
|
|
powerRestartBladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade server.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad."
|
|
::= { bladePowerRestartEntry 5 }
|
|
|
|
powerRestartBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladePowerRestartEntry 6 }
|
|
|
|
-- 6.3.2 & 6.4.2
|
|
powerOnOffBlade OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power on or off a specific blade.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePowerRestartEntry 7 }
|
|
|
|
-- 7.2
|
|
restartBlade OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePowerRestartEntry 8 }
|
|
|
|
-- 7.4
|
|
restartBladeSMP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade's system management processor.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePowerRestartEntry 9 }
|
|
|
|
restartBladeNMI OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Soft reset and initiate a dump on a blade. This option is not supported
|
|
on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePowerRestartEntry 10 }
|
|
|
|
restartBladeClearNVRAM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade and set NVRAM to default values. This option is not
|
|
supported on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePowerRestartEntry 11 }
|
|
|
|
restartBladeInvokeDiags OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade and boot into diagnostic mode. This option is not
|
|
supported on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePowerRestartEntry 12 }
|
|
|
|
restartBladeInvokeDiagsFromDefaultBootList OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade and boot into diagnostic mode from Default Boot List
|
|
as defined on the blade. This option is not supported on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { bladePowerRestartEntry 13 }
|
|
|
|
|
|
bladeConfiguration OBJECT IDENTIFIER ::= { processorBlade 7 }
|
|
-- blade power/restart control
|
|
|
|
bladeConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeConfigurationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade remote power control information.
|
|
Contains power on/off enablement status for each blade."
|
|
::= { bladeConfiguration 1 }
|
|
|
|
bladeConfigurationEntry OBJECT-TYPE
|
|
SYNTAX BladeConfigurationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade configuration table entry"
|
|
INDEX { configurationIndex }
|
|
::= { bladeConfigurationTable 1 }
|
|
|
|
|
|
BladeConfigurationEntry ::= SEQUENCE {
|
|
configurationIndex INTEGER,
|
|
configurationBladeId INTEGER,
|
|
configurationBladeExists INTEGER,
|
|
configurationBladePowerState INTEGER,
|
|
configurationBladeName OCTET STRING
|
|
}
|
|
|
|
configurationIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade configuration table index."
|
|
::= { bladeConfigurationEntry 1 }
|
|
|
|
|
|
configurationBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeConfigurationEntry 2 }
|
|
|
|
configurationBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeConfigurationEntry 3 }
|
|
|
|
configurationBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified is powered on or not."
|
|
::= { bladeConfigurationEntry 4 }
|
|
|
|
configurationBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeConfigurationEntry 5 }
|
|
|
|
|
|
-- Power Management Policy Settings
|
|
bladePowerManagementPolicy OBJECT IDENTIFIER ::= { bladeConfiguration 2 }
|
|
|
|
powerdomain1Oversubscription OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
not-allowed(0),
|
|
recoverable(1),
|
|
non-recoverable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Management Policy settings for power domain 1."
|
|
::= { bladePowerManagementPolicy 1 }
|
|
|
|
powerdomain2Oversubscription OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
not-allowed(0),
|
|
recoverable(1),
|
|
non-recoverable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Management Policy settings for power domain 2."
|
|
::= { bladePowerManagementPolicy 2 }
|
|
|
|
acousticMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acoustic mode setting for thermal conditions"
|
|
::= { bladePowerManagementPolicy 3 }
|
|
|
|
-- 22.1.8
|
|
bladeIPAddrRangeStart OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure IP address range for all the blades.
|
|
Example: the start IP address range of value 10.1.1.1 will
|
|
make blade 1 to have IP address 10.1.1.1, blade 2 to have 10.1.1.2
|
|
and so on."
|
|
::= { processorBlade 8 }
|
|
|
|
|
|
bladeCapacityOnDemand OBJECT IDENTIFIER ::= { processorBlade 9 }
|
|
|
|
bladeCapacityOnDemandTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeCapacityOnDemandEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of COD blade."
|
|
::= { bladeCapacityOnDemand 1 }
|
|
|
|
bladeCapacityOnDemandEntry OBJECT-TYPE
|
|
SYNTAX BladeCapacityOnDemandEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade COD table entry"
|
|
INDEX { bladeCapacityOnDemandIndex }
|
|
::= { bladeCapacityOnDemandTable 1 }
|
|
|
|
|
|
BladeCapacityOnDemandEntry ::= SEQUENCE {
|
|
bladeCapacityOnDemandIndex INTEGER,
|
|
bladeCapacityOnDemandBladeName OCTET STRING,
|
|
bladeCapacityOnDemandState INTEGER
|
|
}
|
|
|
|
bladeCapacityOnDemandIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade configuration table index."
|
|
::= { bladeCapacityOnDemandEntry 1 }
|
|
|
|
bladeCapacityOnDemandBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeCapacityOnDemandEntry 2 }
|
|
|
|
bladeCapacityOnDemandState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
standby(1),
|
|
active(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of COD."
|
|
::= { bladeCapacityOnDemandEntry 3 }
|
|
|
|
|
|
-- JL BEGIN
|
|
-- CIRPAK_MODS
|
|
|
|
bladeBootCountPowerOnTime OBJECT IDENTIFIER ::= { processorBlade 10 }
|
|
-- blade Count of number of boots for a blade and its Power On Time
|
|
|
|
bladeBootCountPowerOnTimeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeBootCountPowerOnTimeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table per blade of the number of boots for the blade and
|
|
the number of seconds the blade has been powered on."
|
|
::= { bladeBootCountPowerOnTime 1 }
|
|
|
|
bladeBootCountPowerOnTimeEntry OBJECT-TYPE
|
|
SYNTAX BladeBootCountPowerOnTimeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of boots for the blade and
|
|
the number of seconds the blade has been powered on."
|
|
INDEX { bootCountPowerOnTimeBladeIndex }
|
|
::= { bladeBootCountPowerOnTimeTable 1 }
|
|
|
|
|
|
BladeBootCountPowerOnTimeEntry ::= SEQUENCE {
|
|
bootCountPowerOnTimeBladeIndex INTEGER,
|
|
bootCountPowerOnTimeBladeId INTEGER,
|
|
bootCountPowerOnTimeBoots INTEGER,
|
|
bootCountPowerOnTimeSecs INTEGER
|
|
|
|
}
|
|
|
|
bootCountPowerOnTimeBladeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade boot count/Power On Time table index."
|
|
::= { bladeBootCountPowerOnTimeEntry 1 }
|
|
|
|
bootCountPowerOnTimeBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeBootCountPowerOnTimeEntry 2 }
|
|
|
|
bootCountPowerOnTimeBoots OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Boot Count. If there is no blade in the
|
|
given slot then this value is undefined. Writing this
|
|
value resets the Boot Count to zero."
|
|
::= { bladeBootCountPowerOnTimeEntry 3 }
|
|
|
|
bootCountPowerOnTimeSecs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Power On Time in seconds. If there is no blade in
|
|
the given slot then this value is undefined. Writing this
|
|
value resets the Power On Time to zero."
|
|
::= { bladeBootCountPowerOnTimeEntry 4 }
|
|
|
|
-- CIRPAK_MODS END
|
|
-- JL END
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Blade failover
|
|
-- ********************************************************************************
|
|
-- 22.2
|
|
-- mmRedundancy OBJECT IDENTIFIER ::= { bladeCenter 2 }
|
|
-- MM failover feature
|
|
--
|
|
-- 22.2.1
|
|
-- mmDisableFailover OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- disabled(0),
|
|
-- enabled(1)
|
|
-- }
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Enables or disables the failover feature from one MM to
|
|
-- another in a redundantly populated server blade system.
|
|
-- The data value of 0x01 represents enabled and the data
|
|
-- value of 0x00 is disabled. When the failover is disabled,
|
|
-- a reset will result in a MM reset. When the failover is
|
|
-- enabled, a MM reset will result in the redundant MM
|
|
-- becoming prime."
|
|
-- ::= { mmRedundancy 1 }
|
|
--
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module control and config
|
|
-- ********************************************************************************
|
|
-- 22.3
|
|
switchModule OBJECT IDENTIFIER ::= { bladeCenter 3 }
|
|
-- Server blade switch module control and configuration
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module control
|
|
-- ********************************************************************************
|
|
-- 22.3.1
|
|
switchModuleControl OBJECT IDENTIFIER ::= { switchModule 1 }
|
|
-- Server blade switch module control
|
|
|
|
smControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module control table."
|
|
::= { switchModuleControl 1 }
|
|
|
|
smControlEntry OBJECT-TYPE
|
|
SYNTAX SmControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module control table entry"
|
|
INDEX { smControlIndex }
|
|
::= { smControlTable 1 }
|
|
|
|
SmControlEntry ::= SEQUENCE {
|
|
smControlIndex INTEGER,
|
|
switchModuleControlId INTEGER,
|
|
smPostResultsAvailable INTEGER,
|
|
smPostResultsValue OCTET STRING,
|
|
switchModuleMemDiagEnableDisable INTEGER,
|
|
smCfgCtrlEnableDisable INTEGER,
|
|
smExtEthPortsEnableDisable INTEGER,
|
|
switchPingRequest INTEGER,
|
|
smCfgCtrlOnResetEnableDisable INTEGER,
|
|
smHealthState INTEGER
|
|
}
|
|
|
|
smControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module control table index."
|
|
::= { smControlEntry 1 }
|
|
|
|
switchModuleControlId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smControlEntry 2 }
|
|
|
|
-- 22.3.1.7
|
|
smPostResultsAvailable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Describes whether the switch module POST diagnostic result
|
|
value contained in the smPostResultsValue is valid."
|
|
::= { smControlEntry 3 }
|
|
|
|
-- 22.3.1.7
|
|
smPostResultsValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The range of values and meanings are as follows:
|
|
0x00 - 0x7F ( 0 - 127) Base internal functions
|
|
0x80 - 0x9F (128 - 159) Internal interface failures
|
|
0xA0 - 0xAF (160 - 175) External interface failures
|
|
0xB0 - 0xFE (176 - 254) Reserved
|
|
0xFF (255) Switch completed POST successfully"
|
|
::= { smControlEntry 4 }
|
|
|
|
-- 22.3.1.4
|
|
switchModuleMemDiagEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(0),
|
|
disabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module memory diagnostics enabled or disabled."
|
|
::= { smControlEntry 5 }
|
|
|
|
-- 22.3.1.5
|
|
smCfgCtrlEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(0),
|
|
disabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module configuration control enabled or disabled."
|
|
::= { smControlEntry 6 }
|
|
|
|
-- 22.3.1.6
|
|
smExtEthPortsEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module external ethernet ports enabled or disabled."
|
|
::= { smControlEntry 7 }
|
|
|
|
-- 22.3.1.8
|
|
switchPingRequest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sends a ping to a switch module's current IP address.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { smControlEntry 8 }
|
|
|
|
-- 22.3.1.9
|
|
smCfgCtrlOnResetEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(0),
|
|
disabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module configuration control enabled or disabled on resets
|
|
(default and unsolicited)."
|
|
::= { smControlEntry 9 }
|
|
|
|
-- 22.3.1.15
|
|
smHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the switch module.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad."
|
|
::= { smControlEntry 15}
|
|
|
|
|
|
-- 22.3.1.7
|
|
smPowerRestartTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmPowerRestartEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module power restart table."
|
|
::= { switchModuleControl 7 }
|
|
|
|
smPowerRestartEntry OBJECT-TYPE
|
|
SYNTAX SmPowerRestartEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module power restart table entry"
|
|
INDEX { smPowerRestartIndex }
|
|
::= { smPowerRestartTable 1 }
|
|
|
|
SmPowerRestartEntry ::= SEQUENCE {
|
|
smPowerRestartIndex INTEGER,
|
|
smPowerRestartId INTEGER,
|
|
smSwitchExists INTEGER,
|
|
smSwitchType INTEGER,
|
|
smMACAddress OCTET STRING,
|
|
smIPAddress IpAddress,
|
|
switchModulePowerOnOff INTEGER,
|
|
smReset INTEGER,
|
|
smResetToDefault INTEGER,
|
|
smRestartAndRunStdDiag INTEGER,
|
|
smRestartAndRunExtDiag INTEGER,
|
|
smRestartAndRunFullDiag INTEGER
|
|
}
|
|
|
|
smPowerRestartIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module power restart index."
|
|
::= { smPowerRestartEntry 1 }
|
|
|
|
smPowerRestartId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smPowerRestartEntry 2 }
|
|
|
|
smSwitchExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not."
|
|
::= { smPowerRestartEntry 3 }
|
|
|
|
smSwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
opm(3),
|
|
serialCM(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module type."
|
|
::= { smPowerRestartEntry 4 }
|
|
|
|
smMACAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module MAC address."
|
|
::= { smPowerRestartEntry 5 }
|
|
|
|
-- 22.3.2.1.1.1
|
|
smIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current IP address."
|
|
::= { smPowerRestartEntry 6 }
|
|
|
|
-- 22.3.1.1
|
|
switchModulePowerOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poweroff(0),
|
|
poweron(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module power on or power off. If powering on a currently
|
|
powered off switch module, then the switch module will execute a POST.
|
|
The results of this POST will need to be retrieved using the 'Post Results'
|
|
command. Note: When powering off a currently powered on switch module,
|
|
a minimum of 1 second is needed to allow the switch to power off
|
|
before powering back on the switch."
|
|
::= { smPowerRestartEntry 7 }
|
|
|
|
-- 22.3.1.2
|
|
smReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the case where the switch module is currently powered on, this command
|
|
will effectively power off and then power on the switch module indicated and
|
|
cause it to run its POST test. For the case where the switch module is
|
|
currently powered off, the command will just power on the switch module.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB."
|
|
::= { smPowerRestartEntry 8 }
|
|
|
|
-- 22.3.1.3
|
|
smResetToDefault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the case where the switch module is currently powered on, this command
|
|
will effectively power off and then power on the switch module indicated and
|
|
cause it to run its POST test. For the case where the switch module is
|
|
currently powered off, the command will just power on the switch module.
|
|
In both cases, the switch module will reset the configuration to the default
|
|
values.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB."
|
|
::= { smPowerRestartEntry 9 }
|
|
|
|
-- 22.3.1.2
|
|
smRestartAndRunStdDiag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To power cycle the selected module(s) and then run the standard diagnostic
|
|
test package.
|
|
|
|
NOTE: Value returned for the GET commnad is meaningless for this MIB."
|
|
::= { smPowerRestartEntry 10 }
|
|
|
|
-- 22.3.1.2.1
|
|
smRestartAndRunExtDiag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To power cycle the selected module(s) and then run the extended diagnostic
|
|
test package. This option is not supported on all I/O modules.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB."
|
|
::= { smPowerRestartEntry 11 }
|
|
|
|
-- 22.3.1.2.2
|
|
smRestartAndRunFullDiag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To power cycle the selected module(s) and then run the full diagnostic test
|
|
package. The full diagnostic test package may take over 5 minutes to run.
|
|
This option is not supported on all I/O modules.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB."
|
|
::= { smPowerRestartEntry 12 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module config
|
|
-- ********************************************************************************
|
|
-- 22.3.2
|
|
switchModuleConfig OBJECT IDENTIFIER ::= { switchModule 2 }
|
|
-- Server blade switch module configuration
|
|
|
|
-- 22.3.2.1
|
|
switchMgmtNetworkCfg OBJECT IDENTIFIER ::= { switchModuleConfig 1 }
|
|
-- Server blade switch module management network config
|
|
|
|
--
|
|
-- Current switch module network config
|
|
--
|
|
-- 22.3.2.1.1
|
|
switchCurrentNwCfg OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 1 }
|
|
-- Server blade switch module current network config
|
|
|
|
smCurrentIPInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmCurrentIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module current IP information."
|
|
::= { switchCurrentNwCfg 1 }
|
|
|
|
smCurrentIPInfoEntry OBJECT-TYPE
|
|
SYNTAX SmCurrentIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module current IP table entry"
|
|
INDEX { smCurrentIPInfoIndex }
|
|
::= { smCurrentIPInfoTable 1 }
|
|
|
|
SmCurrentIPInfoEntry ::= SEQUENCE {
|
|
smCurrentIPInfoIndex INTEGER,
|
|
smCurrentIPInfoId INTEGER,
|
|
smCurrentIPInfoExists INTEGER,
|
|
smCurrentIPInfoPowerState INTEGER,
|
|
-- smCurrentIPInfoErrorStatus INTEGER,
|
|
smCurrentIPAddr IpAddress,
|
|
smCurrentSubnetMask IpAddress,
|
|
smCurrentGateway IpAddress,
|
|
smCurrentIPConfigMethod INTEGER
|
|
}
|
|
|
|
smCurrentIPInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module current IP info index."
|
|
::= { smCurrentIPInfoEntry 1 }
|
|
|
|
smCurrentIPInfoId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smCurrentIPInfoEntry 2 }
|
|
|
|
smCurrentIPInfoExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not."
|
|
::= { smCurrentIPInfoEntry 3 }
|
|
|
|
smCurrentIPInfoPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified is powered on or not."
|
|
::= { smCurrentIPInfoEntry 4 }
|
|
|
|
-- smCurrentIPInfoErrorStatus OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- noerror(0),
|
|
-- warning(1),
|
|
-- error(3)
|
|
-- }
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Indicates whether the switch module specified has encountered an
|
|
-- error condition."
|
|
-- ::= { smCurrentIPInfoEntry 5 }
|
|
|
|
-- 22.3.2.1.1.1
|
|
smCurrentIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current IP address."
|
|
::= { smCurrentIPInfoEntry 6 }
|
|
|
|
|
|
-- 22.3.2.1.1.2
|
|
smCurrentSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current subnet mask."
|
|
::= { smCurrentIPInfoEntry 7 }
|
|
|
|
-- 22.3.2.1.1.3
|
|
smCurrentGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current IP gateway."
|
|
::= { smCurrentIPInfoEntry 8 }
|
|
|
|
-- 22.3.2.1.1.4
|
|
smCurrentIPConfigMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
static(1),
|
|
dhcp(2),
|
|
bootp(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current IP configuration method."
|
|
::= { smCurrentIPInfoEntry 9 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- New switch module network config
|
|
-- ********************************************************************************
|
|
-- 22.3.2.1.2
|
|
switchNewNwCfg OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 2 }
|
|
-- Server blade switch module new network config
|
|
|
|
-- 22.3.2.1.2.1
|
|
smNewIPInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNewIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module new IP information."
|
|
::= { switchNewNwCfg 1 }
|
|
|
|
smNewIPInfoEntry OBJECT-TYPE
|
|
SYNTAX SmNewIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module new IP configuration information table entry"
|
|
INDEX { smNewIPInfoIndex }
|
|
::= { smNewIPInfoTable 1 }
|
|
|
|
SmNewIPInfoEntry ::= SEQUENCE {
|
|
smNewIPInfoIndex INTEGER,
|
|
smNewIPInfoId INTEGER,
|
|
smNewIPInfoExists INTEGER,
|
|
smNewIPInfoPowerState INTEGER,
|
|
smNewIPAddr IpAddress,
|
|
smNewSubnetMask IpAddress,
|
|
smNewGateway IpAddress,
|
|
smNewIPConfigMethod INTEGER,
|
|
smNewIPConfigEnableDisable INTEGER
|
|
}
|
|
|
|
smNewIPInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module new IP info index."
|
|
::= { smNewIPInfoEntry 1 }
|
|
|
|
smNewIPInfoId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smNewIPInfoEntry 2 }
|
|
|
|
smNewIPInfoExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not."
|
|
::= { smNewIPInfoEntry 3 }
|
|
|
|
smNewIPInfoPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified is powered on or not."
|
|
::= { smNewIPInfoEntry 4 }
|
|
|
|
-- smNewIPInfoErrorStatus OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- noerror(0),
|
|
-- warning(1),
|
|
-- error(3)
|
|
-- }
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Indicates whether the switch module specified has encountered an
|
|
-- error condition."
|
|
-- ::= { smNewIPInfoEntry 5 }
|
|
|
|
-- 22.3.2.1.2.1
|
|
smNewIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module new IP address."
|
|
::= { smNewIPInfoEntry 6 }
|
|
|
|
|
|
-- 22.3.2.1.2.2
|
|
smNewSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module new subnet mask."
|
|
::= { smNewIPInfoEntry 7 }
|
|
|
|
-- 22.3.2.1.2.3
|
|
smNewGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module new IP gateway."
|
|
::= { smNewIPInfoEntry 8 }
|
|
|
|
-- 22.3.2.1.2.4
|
|
smNewIPConfigMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
static(1),
|
|
dhcp(2),
|
|
bootp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module new IP configuration method."
|
|
::= { smNewIPInfoEntry 9 }
|
|
|
|
-- 22.3.2.1.2.5
|
|
smNewIPConfigEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A set command enables a new IP configuration that has been
|
|
previously defined. A get command indicates whether the new
|
|
IP configuration information has been enabled."
|
|
::= { smNewIPInfoEntry 10 }
|
|
|
|
|
|
|
|
-- 4.5.9
|
|
chassisTopology OBJECT IDENTIFIER ::= { bladeCenter 4 }
|
|
|
|
chassisResponseVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis response version."
|
|
::= { chassisTopology 1 }
|
|
|
|
chassisFlags OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
serverBlade(1),
|
|
rackOrStandAlone(0)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis flags.
|
|
1 = a server blade chassis, 0 = a rack or standalone chassis."
|
|
::= { chassisTopology 2 }
|
|
|
|
chassisName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the chassis as a null terminated string."
|
|
::= { chassisTopology 3 }
|
|
|
|
chassisNoOfPBsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of processor blades (PBs) supported."
|
|
::= { chassisTopology 19 }
|
|
|
|
chassisNoOfSMsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of switch modules (SMs) supported."
|
|
::= { chassisTopology 20 }
|
|
|
|
chassisNoOfMMsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of management modules (MMs) supported."
|
|
::= { chassisTopology 21 }
|
|
|
|
chassisNoOfPMsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of processor modules (PMs) supported."
|
|
::= { chassisTopology 22 }
|
|
|
|
chassisNoOfMTsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of media trays (MTs) supported."
|
|
::= { chassisTopology 23 }
|
|
|
|
chassisNoOfBlowersSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of blowers supported."
|
|
::= { chassisTopology 24 }
|
|
|
|
chassisPBsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blades that are installed on the chassis.
|
|
The blades are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blades supported. If a blade is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if blades
|
|
are installed in bays 1, 5, and 13, and 14 blades are supported,
|
|
the string would look like '10001000000010'."
|
|
::= { chassisTopology 25 }
|
|
|
|
chassisSMsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch modules that are installed on the chassis.
|
|
The switch modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of switch modules supported. If a switch module is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if switch modules are installed in bays 1 and 3, and 4 switch modules
|
|
are supported, the string would look like '1010'."
|
|
::= { chassisTopology 29 }
|
|
|
|
chassisMMsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The management modules that are installed on the chassis.
|
|
The management modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as the
|
|
number of management modules supported. If a management module is installed
|
|
in a bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if a management module
|
|
is installed in bay 1, and 2 management modules are supported, the
|
|
string would look like '10'."
|
|
::= { chassisTopology 30 }
|
|
|
|
chassisPMsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power modules that are installed on the chassis.
|
|
The power modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of power modules supported. If a power module is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if power modules are installed in bays 1 and 3, and 4 power modules
|
|
are supported, the string would look like '1010'."
|
|
::= { chassisTopology 31 }
|
|
|
|
chassisMTInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a media tray (MT) is installed."
|
|
::= { chassisTopology 32 }
|
|
|
|
chassisBlowersInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blowers that are installed on the chassis.
|
|
The blowers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blowers supported. If a blower is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if a blower
|
|
is installed in bay 1, and 2 blowers are supported, the string
|
|
would look like '10'."
|
|
::= { chassisTopology 33 }
|
|
|
|
chassisActiveMM OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The active management module (MM)."
|
|
::= { chassisTopology 34 }
|
|
|
|
chassisKVMOwner OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade that currently owns the keyboard/video/monitor (KVM).
|
|
0 = the KVM devices are owned by the management module."
|
|
::= { chassisTopology 35 }
|
|
|
|
chassisMediaTrayOwner OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade that currently owns the media tray.
|
|
0 = the media tray is owned by the management module."
|
|
::= { chassisTopology 36 }
|
|
|
|
--
|
|
managementModule OBJECT IDENTIFIER ::= { bladeCenter 5 }
|
|
|
|
mmStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the management module status.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { managementModule 1 }
|
|
|
|
mmStatusEntry OBJECT-TYPE
|
|
SYNTAX MmStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module status entry.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
INDEX { mmStatusIndex }
|
|
::= { mmStatusTable 1 }
|
|
|
|
MmStatusEntry ::= SEQUENCE {
|
|
mmStatusIndex INTEGER,
|
|
mmPresent INTEGER,
|
|
mmExtIpAddress IpAddress,
|
|
mmPrimary INTEGER
|
|
}
|
|
|
|
mmStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module status index."
|
|
::= { mmStatusEntry 1 }
|
|
|
|
mmPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module current status."
|
|
::= { mmStatusEntry 2 }
|
|
|
|
mmExtIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module external IP address."
|
|
::= { mmStatusEntry 3 }
|
|
|
|
mmPrimary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicate if this Management module is a primary or not."
|
|
::= { mmStatusEntry 4 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Firmware update for MM, Switch modules, and blades
|
|
-- ********************************************************************************
|
|
firmwareUpdate OBJECT IDENTIFIER ::= { bladeCenter 9 }
|
|
|
|
firmwareUpdateTarget OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
managementModule(0),
|
|
switchModule1(2),
|
|
switchModule2(3),
|
|
switchModule3(4),
|
|
switchModule4(5),
|
|
blade1(10),
|
|
blade2(11),
|
|
blade3(12),
|
|
blade4(13),
|
|
blade5(14),
|
|
blade6(15),
|
|
blade7(16),
|
|
blade8(17),
|
|
blade9(18),
|
|
blade10(19),
|
|
blade11(20),
|
|
blade12(21),
|
|
blade13(22),
|
|
blade14(23),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Target module whose firmware will be updated.
|
|
Note: Some switch modules do not allow firmware update.
|
|
When firmware update is attempted on those switch modules,
|
|
the agent will report an error."
|
|
::= { firmwareUpdate 1 }
|
|
|
|
firmwareUpdateTftpServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TFTP server where the firmware file resides.
|
|
The address must be entered in a dotted decimal IP string
|
|
(eg. 9.37.44.2)."
|
|
::= { firmwareUpdate 2 }
|
|
|
|
firmwareUpdateFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File name of the firmware file."
|
|
::= { firmwareUpdate 3 }
|
|
|
|
firmwareUpdateStart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Start updating the firmware of the specified target module.
|
|
Note 1: Depending on the target, it might take up to several
|
|
minutes for the flash update to complete. Do not reset the
|
|
target until the control has been returned. At this point,
|
|
the results will be displayed.
|
|
Note 2 : Use firmwareUpdateStatus to confirm the status of
|
|
the last firmware update initiated by SNMP method. The
|
|
Management Module must be restarted for the new firmware to
|
|
take affect.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB."
|
|
::= { firmwareUpdate 4 }
|
|
|
|
|
|
firmwareUpdateStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get the status of the last firmware update which was
|
|
initiated through SNMP method."
|
|
::= { firmwareUpdate 5 }
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- IPMI Management
|
|
-- ********************************************************************************
|
|
ipmiManagement OBJECT IDENTIFIER ::= { bladeCenter 20 }
|
|
|
|
ipmiEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ipmiDisabled(0),
|
|
ipmiEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/enable IPMI feature and read the status through SNMP method."
|
|
|
|
::= { ipmiManagement 1 }
|
|
|
|
END
|