mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-18 00:13:02 +00:00
1115 lines
30 KiB
Plaintext
1115 lines
30 KiB
Plaintext
-- *****************************************************************
|
|
-- BASIS SHELF MIB
|
|
--
|
|
-- August 2001
|
|
--
|
|
-- Copyright (c) 1996-2001 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
--
|
|
-- LAST-UPDATED "200109210000Z"
|
|
-- DESCRIPTION "This MIB contains information on the shelf and
|
|
-- redundancy configuration.
|
|
-- The shelf information constitutes the card types
|
|
-- for the front modules and the module state.
|
|
--
|
|
-- The redundancy information constitutes the
|
|
-- configuring the redundancy between the service modules
|
|
-- and service resource modules."
|
|
--
|
|
-- REVISION "200109210000Z"
|
|
-- DESCRIPTION
|
|
-- "Added following enumerations in <shelfFunctionModuleState>,
|
|
-- <redPrimaryState> and <redSecondaryState>
|
|
-- notResponding(14)
|
|
-- cardinit(17)
|
|
-- "
|
|
--
|
|
-- REVISION "200108230000Z"
|
|
-- DESCRIPTION
|
|
-- "-
|
|
--
|
|
|
|
BASIS-SHELF-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
IpAddress FROM RFC1155-SMI
|
|
OBJECT-TYPE FROM RFC-1212
|
|
DisplayString FROM RFC1213-MIB
|
|
basisShelf,axisRedundancy FROM BASIS-MIB;
|
|
|
|
|
|
|
|
-- shelfTable OBJECT IDENTIFIER ::= {basisShelf 1}
|
|
-- shelfNumOfValidEntries OBJECT IDENTIFIER ::= {basisShelf 2}
|
|
-- shelfNodeName OBJECT IDENTIFIER ::= {basisShelf 3}
|
|
-- shelfDate OBJECT IDENTIFIER ::= {basisShelf 4}
|
|
-- shelfTime OBJECT IDENTIFIER ::= {basisShelf 5}
|
|
-- shelfTmZn OBJECT IDENTIFIER ::= {basisShelf 6}
|
|
-- shelfTmZnGMTOff OBJECT IDENTIFIER ::= {basisShelf 7}
|
|
-- shelfBkPlnType OBJECT IDENTIFIER ::= {basisShelf 8}
|
|
-- shelfBkplnSerialNum OBJECT IDENTIFIER ::= {basisShelf 9}
|
|
-- statsMasterIpAddress OBJECT IDENTIFIER ::= {basisShelf 10}
|
|
-- statsCollectionInterval OBJECT IDENTIFIER ::= {basisShelf 11}
|
|
-- statsBucketInterval OBJECT IDENTIFIER ::= {basisShelf 12}
|
|
-- userName OBJECT IDENTIFIER ::= {basisShelf 13}
|
|
-- shelfIntegratedAlarm OBJECT IDENTIFIER ::= {basisShelf 14}
|
|
-- shelfAlarmCardBitMap OBJECT IDENTIFIER ::= {basisShelf 15}
|
|
-- axisFeederTkNo OBJECT IDENTIFIER ::= {basisShelf 16}
|
|
-- axisSvcBillingColInterval OBJECT IDENTIFIER ::= {basisShelf 17}
|
|
-- axisSvcBillingBucketInterval OBJECT IDENTIFIER ::= {basisShelf 18}
|
|
-- apsIpAddress OBJECT IDENTIFIER ::= {basisShelf 19}
|
|
-- redundantApsIpAddress OBJECT IDENTIFIER ::= {basisShelf 20}
|
|
-- axisSvcBilling OBJECT IDENTIFIER ::= {basisShelf 21}
|
|
-- shelfCBClkRateTable OBJECT IDENTIFIER ::= {basisShelf 22}
|
|
-- shelfPowerSupplyVoltage OBJECT IDENTIFIER ::= {basisShelf 23}
|
|
--
|
|
--
|
|
-- shelf table
|
|
--
|
|
--
|
|
-- ----------------------------------------------------------------
|
|
shelfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ShelfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The table has the Physical slot number and state of the cards
|
|
"
|
|
::= { basisShelf 1 }
|
|
|
|
shelfEntry OBJECT-TYPE
|
|
SYNTAX ShelfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry for the slot
|
|
"
|
|
INDEX { shelfNum, shelfSlotNum }
|
|
::= { shelfTable 1}
|
|
|
|
ShelfEntry ::=
|
|
SEQUENCE {
|
|
shelfNum
|
|
INTEGER,
|
|
shelfSlotNum
|
|
INTEGER,
|
|
shelfBkplnSerialNumDeprecated
|
|
INTEGER,
|
|
shelfFunctionModuleState
|
|
INTEGER,
|
|
shelfFunctionModuleType
|
|
INTEGER,
|
|
shelfFunctionModuleHoldReset
|
|
INTEGER
|
|
}
|
|
|
|
|
|
shelfNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each shelf. Its value
|
|
ranges between 1 and the maxvalue of shelfNumber.
|
|
"
|
|
::= { shelfEntry 1 }
|
|
|
|
|
|
shelfSlotNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..33)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Slot number of a card.
|
|
BASIS can have maximum 16 slots in one shelf.
|
|
17 is used to reset the whole shelf.
|
|
Some MGX Series can have maximum 32 slots in one shelf.
|
|
33 is used to reset the whole shelf.
|
|
For MGX8220:
|
|
INTEGER (1..17)
|
|
For other selected MGX series:
|
|
INTEGER (1..33)
|
|
"
|
|
::= { shelfEntry 2 }
|
|
|
|
shelfBkplnSerialNumDeprecated OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry has been deprecated. It is available as the 9th
|
|
entry in basisShelf. It is included here to prevent a hole
|
|
in the shelfEntry table.
|
|
"
|
|
::= { shelfEntry 3 }
|
|
|
|
shelfFunctionModuleState OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
nocard (1),
|
|
standby (2),
|
|
active (3),
|
|
failed (4),
|
|
selfTest (5),
|
|
heldInReset (6),
|
|
boot (7),
|
|
mismatch (8),
|
|
unknown (9),
|
|
coreCardMismatch (10),
|
|
blocked (11),
|
|
reserved (12),
|
|
-- hold state applies to PXM during Graceful Upgrade.
|
|
hold (13),
|
|
notResponding (14),
|
|
cardinit (17)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object holds the status of a card in a particular shelf-slot.
|
|
The hold state is applicable only to MGX8800 Platform.
|
|
The Slave PXM assumes the hold state during PXM Upgrades. In this
|
|
state the Slave PXM will be running a different fw but will be
|
|
receiving all Standby updates(BRAM and Database).
|
|
The description for the two new states is as follows:
|
|
'notResponding' - Response from the Service module has become slow
|
|
probably due to overloading of CPU.
|
|
No recovery action is required on user part.
|
|
At present, this state is implemented only for RPM card.
|
|
'cardinit' - When the physical presence of card has been detected
|
|
but the communication hasn't yet been established between the
|
|
controller card (PXM) and Service Module.
|
|
"
|
|
::= { shelfEntry 4 }
|
|
|
|
shelfFunctionModuleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
asc (2),
|
|
bnm-T3 (10),
|
|
bnm-E3 (11),
|
|
bnm-155 (12),
|
|
srm-4T1E1 (20),
|
|
srm-3T3 (21),
|
|
-- SRME cards
|
|
srme-1OC3 (22),
|
|
srme-1STS3(23),
|
|
srme-NOBC(24),
|
|
srm-3T3-NOBC(25),
|
|
|
|
frsm-4T1 (30),
|
|
frsm-4E1 (31),
|
|
frsm-4T1-C(32),
|
|
frsm-4E1-C(33),
|
|
-- HSSI:
|
|
frsm-hs1 (34),
|
|
-- HSSI
|
|
frsm-8T1 (35),
|
|
frsm-8E1 (36),
|
|
frsm-hs1b (37),
|
|
ausm-4T1 (40),
|
|
ausm-4E1 (41),
|
|
ausm-8T1 (50),
|
|
ausm-8E1 (51),
|
|
-- AUSM Model B :
|
|
ausmB-8T1 (52),
|
|
ausmB-8E1 (53),
|
|
cesm-4T1 (60),
|
|
cesm-4E1 (61),
|
|
imatm-T3T1 (70),
|
|
imatm-E3E1 (71),
|
|
imatmB-T1 (72),
|
|
imatmB-E1 (73),
|
|
|
|
frasm-8T1 (80),
|
|
|
|
cesm-8T1 (90),
|
|
cesm-8E1 (91),
|
|
|
|
-- SM from Netro
|
|
bscsm-2 (100),
|
|
bscsm-4 (101),
|
|
|
|
-- testers
|
|
atmt-8T1 (110),
|
|
atmt-8E1 (111),
|
|
frt-8T1 (120),
|
|
frt-8E1 (121),
|
|
|
|
-- frsm_vhs cards
|
|
frsm-2ct3 (130),
|
|
frsm-2t3 (131),
|
|
frsm-2e3 (132),
|
|
frsm-hs2 (133),
|
|
frsm-2t3b (134),
|
|
frsm-2e3b (135),
|
|
frsm-hs2b-hssi (136),
|
|
frsm-hs2b-12In1 (137),
|
|
|
|
cesm-T3 (140),
|
|
cesm-E3 (141),
|
|
|
|
-- VISM
|
|
vism-8T1 (150),
|
|
vism-8E1 (151),
|
|
|
|
pxm1 (1000),
|
|
pxm1-2t3e3 (1001),
|
|
pxm1-4oc3 (1002),
|
|
pxm1-oc12 (1003),
|
|
|
|
rpm (2000),
|
|
rpm-pr (2001)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object holds the type of a card in
|
|
a particular shelf-slot.
|
|
"
|
|
DEFVAL { other }
|
|
::= { shelfEntry 5 }
|
|
|
|
shelfFunctionModuleHoldReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
doNotHold (1),
|
|
holdInReset(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object holds the card in
|
|
a particular shelf-slot, in reset,
|
|
If the object is set to holdInReset.
|
|
If the object is set to doNotHold, then
|
|
it only reset the card in the specified
|
|
slot, if slot number is 17 then it'll
|
|
reset the whole shelf.
|
|
"
|
|
::= { shelfEntry 6 }
|
|
-- --------------------------------------------------------------
|
|
|
|
shelfNumOfValidEntries OBJECT-TYPE
|
|
SYNTAX INTEGER (0..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of rows in shelfTable.
|
|
In some MGX series, it is equal to the number of slots
|
|
in the shelf.
|
|
"
|
|
::= { basisShelf 2 }
|
|
|
|
shelfNodeName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Has the node name of BASIS for MGX8220 only.
|
|
For others NodeName supplied by PAR will be returned,
|
|
A set on this MIB is not allowed.
|
|
The NodeName of the shelf can be set using
|
|
the PAR MIB.
|
|
"
|
|
::= { basisShelf 3 }
|
|
|
|
shelfDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets/gets the DATE. The syntax is mm/dd/yyyy
|
|
"
|
|
DEFVAL { "01/01/1994" }
|
|
::= { basisShelf 4 }
|
|
|
|
shelfTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (8))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets/gets the TIME. The syntax is hh:mm:ss
|
|
"
|
|
DEFVAL { "12:00:00" }
|
|
::= { basisShelf 5 }
|
|
|
|
shelfTmZn OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
gmt (1),
|
|
est (2),
|
|
cst (3),
|
|
mst (4),
|
|
pst (5),
|
|
edt (6),
|
|
cdt (7),
|
|
mdt (8),
|
|
pdt (9)
|
|
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Object defines standard time. GMT for greenwich mean time,
|
|
est for Eastern std time (USA EST).
|
|
cst for Central std time (USA CST).
|
|
mst for Mountain std time (USA MST).
|
|
pst for Pacific std time (USA PST).
|
|
edt for Eastern daylight time (USA EDT).
|
|
cdt for Central daylight time (USA CDT).
|
|
mdt for Mountain daylight time (USA MDT).
|
|
pdt for Pacific daylight time (USA PDT).
|
|
To define a std time that are not defined in here use the
|
|
GMT and set the offset from the GMT in the shelfTmZnGMTOff object.
|
|
"
|
|
DEFVAL { pst }
|
|
::= { basisShelf 6 }
|
|
|
|
shelfTmZnGMTOff OBJECT-TYPE
|
|
SYNTAX INTEGER (-12..12)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the offset from greenwich mean time in
|
|
hours, if configuring for std time in shelfTmZn object, set this
|
|
object to 0. If configuring for non standard times use this
|
|
object as an offset from the GMT.
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { basisShelf 7 }
|
|
|
|
|
|
shelfBkPlnType OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the back plane type.
|
|
The possible values are :
|
|
1 - For 336Mbps backplane
|
|
2 - For 1.2Gbps backplane
|
|
3 - For 45Gbps backplane
|
|
"
|
|
::= { basisShelf 8 }
|
|
|
|
shelfBkplnSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..11))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each shelf, entered in nvram
|
|
by manf. The serial No. is on the non-volatile RAM on the
|
|
backplane.
|
|
"
|
|
::= { basisShelf 9 }
|
|
|
|
statsMasterIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Stats Master.
|
|
"
|
|
::= { basisShelf 10 }
|
|
|
|
statsCollectionInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Statistics collection interval (in minutes).
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { basisShelf 11 }
|
|
|
|
|
|
statsBucketInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Statistics bucket interval (in minutes).
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { basisShelf 12 }
|
|
|
|
userName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..20))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"username of the person logging in or logging out. used only in traps
|
|
currently only limit to 12 chars
|
|
"
|
|
::= { basisShelf 13 }
|
|
|
|
|
|
shelfIntegratedAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clear (1),
|
|
minor (2),
|
|
major (3),
|
|
critical (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm status of the shelf.An implementation may not support
|
|
all the values.
|
|
|
|
possible values are :
|
|
|
|
clear (1) : shelf is not in alarm
|
|
minor (2) : Indicates that a non-service affecting condition
|
|
has occurred and that corrective action should
|
|
be taken in order to prevent a more serious fault.
|
|
major (3) : Indicates that a service affecting condition
|
|
has occurred and urgent corrective action is
|
|
required.
|
|
critical (4) : Indicates that a service affecting condition has
|
|
occurred and immediate corrective action is required.
|
|
The definition for minor(2),major(3),critical(4) are taken from
|
|
Bell Core document : GR-1248-CORE.
|
|
"
|
|
DEFVAL { clear }
|
|
::= { basisShelf 14 }
|
|
|
|
|
|
shelfAlarmCardBitMap OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"
|
|
default value is 0, none of the cards is in alarm
|
|
bit position represents the card physical slot
|
|
number which is in alarm
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { basisShelf 15 }
|
|
|
|
|
|
apsIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"the IP address of the APS"
|
|
::= {basisShelf 19}
|
|
|
|
redundantApsIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"the IP address of the redundant APS"
|
|
::= {basisShelf 20}
|
|
|
|
axisFeederTkNo OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"ASC creates its cell/frame file based on the feeder trunk number."
|
|
::= { basisShelf 16}
|
|
|
|
axisSvcBillingColInterval OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
a0minutes (1),
|
|
a15minutes (2),
|
|
a30minutes (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SVC billing collection interval (in 0, 15, 30 minute steps).
|
|
"
|
|
DEFVAL { a30minutes }
|
|
::= { basisShelf 17 }
|
|
|
|
axisSvcBillingBucketInterval OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
a0minutes (1),
|
|
a5minutes (2),
|
|
a15minutes (3),
|
|
a30minutes (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SVC billing bucket interval (in 0, 5, 15, 30 minute steps).
|
|
"
|
|
DEFVAL { a15minutes }
|
|
::= { basisShelf 18 }
|
|
|
|
axisSvcBilling OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SVC billing feature.
|
|
"
|
|
DEFVAL {disable}
|
|
::= { basisShelf 21}
|
|
|
|
shelfCBClkRateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ShelfCBClkRateEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The table has the Clock Rates of each Cell Bus
|
|
"
|
|
::= { basisShelf 22 }
|
|
|
|
shelfCBClkRateEntry OBJECT-TYPE
|
|
SYNTAX ShelfCBClkRateEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry for the Cell Bus
|
|
"
|
|
INDEX { cBNum }
|
|
::= { shelfCBClkRateTable 1}
|
|
|
|
ShelfCBClkRateEntry ::=
|
|
SEQUENCE {
|
|
cBNum
|
|
INTEGER,
|
|
clkRate
|
|
INTEGER
|
|
}
|
|
|
|
cBNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number (1-8) designation for the Cell Bus.
|
|
"
|
|
::= { shelfCBClkRateEntry 1 }
|
|
|
|
|
|
clkRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
twentyOne-Mhz (1),
|
|
fortyTwo-Mhz (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Cell Bus Clock Rate designation.
|
|
"
|
|
::= { shelfCBClkRateEntry 2 }
|
|
|
|
|
|
shelfPowerSupplyVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
two-twenty (1),
|
|
one-ten (2)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Supply voltage rating for some selected
|
|
MGX Series.
|
|
two-twenty (1): 220Volts AC.
|
|
one-ten (2): 110Volts AC.
|
|
"
|
|
|
|
::= { basisShelf 23}
|
|
|
|
-- ----------------------------------------------------------------
|
|
--
|
|
-- Group "axisRedundancy"
|
|
-- This group contains information of the redundancy mapping
|
|
--
|
|
-- Terminology:
|
|
--
|
|
-- Core-Card set in MGX8220 includes : ASC,BNM and SRM
|
|
-- ASC - Axis Shelf Controller
|
|
-- BNM - Broadband Network Module
|
|
-- SRM - Service Redundancy/Resource Module
|
|
--
|
|
-- Core-Card set in MGX8850 includes : PXM,SRM
|
|
-- PXM - Processor Switch Module
|
|
-- SRM - Service Redundancy/Resource module
|
|
--
|
|
-- Core-Card set in some systems include : PXM only
|
|
--
|
|
-- The slot numbers where the Core-Card set can be plugged in may
|
|
-- be different in different products.
|
|
--
|
|
-- A "redundant pair" is a set of cards/modules that may operate
|
|
-- in a redundant manner. At any time one or more cards/modules
|
|
-- of the pair are 'active', while other is 'standby', such
|
|
-- that if an active member fails,one of the standby member becomes
|
|
-- active instead.
|
|
--
|
|
|
|
|
|
smRedMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmRedMapEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The table has the redundancy map for a service module.
|
|
This table is for configuring redundancy for service modules.
|
|
This table might contain entries for Core-Card set,in some
|
|
implementations.
|
|
"
|
|
::= { axisRedundancy 1 }
|
|
|
|
smRedMapEntry OBJECT-TYPE
|
|
SYNTAX SmRedMapEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry for module(Service Module,Core-Card set) redundancy.
|
|
Some implementations might have entries for the core-card set.
|
|
The entries for core-card set may not be added , modified or deleted.
|
|
An entry has to be created in this table to configure Service Modules
|
|
in redundant configuration.
|
|
|
|
For a 1:1 (Y cable ) redundancy configuration,an entry exists for
|
|
each redundant pair with redPrimarySlotNum as the index.
|
|
|
|
For 1:N Redundancy configuration,an entry exists with different
|
|
primary slot numbers(redPrimarySlot value) with the same
|
|
secondary slot numbers(redSecondarySlot value).
|
|
"
|
|
INDEX { redPrimarySlotNum }
|
|
::= { smRedMapTable 1}
|
|
|
|
SmRedMapEntry ::=
|
|
SEQUENCE {
|
|
redPrimarySlotNum
|
|
INTEGER,
|
|
redRowStatus
|
|
INTEGER,
|
|
redPrimaryType
|
|
INTEGER,
|
|
redPrimaryState
|
|
INTEGER,
|
|
redSecondarySlotNum
|
|
INTEGER,
|
|
redSecondaryType
|
|
INTEGER,
|
|
redSecondaryState
|
|
INTEGER,
|
|
redType
|
|
INTEGER,
|
|
redCoveringSlot
|
|
INTEGER,
|
|
redFeature
|
|
INTEGER,
|
|
redLineModuleType
|
|
INTEGER
|
|
}
|
|
|
|
|
|
redPrimarySlotNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..32)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The index to the table. This is the slot number of the
|
|
primary module in the redundant configuration.
|
|
|
|
For MGX8850 Release 1.x,skip PXM slot 7,8,23,24, SRM slot 15,16,31,32.
|
|
|
|
For MGX8220(Formerly known as AXIS), values 5-14 are supported.
|
|
|
|
For systems, where the entries are created by the agent
|
|
for the Core-Card set, the implied slot numbers are used
|
|
for this object. The implied slot number values are depend
|
|
on the system.
|
|
"
|
|
::= { smRedMapEntry 1 }
|
|
|
|
|
|
redRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
add(1),
|
|
del(2),
|
|
mod(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This will add, delete or modify the redundancy
|
|
Note that mod is NOT used but it is there for consistency.
|
|
|
|
This object is for creating and deleting an entry in
|
|
smRedMapTable.
|
|
This object is set to add(1) to create an entry in the table.
|
|
The values of redPrimarySlot and redSecondarySlot objects
|
|
constitute the redundant Pairs. The slot numbers specified for
|
|
redPrimarySlot and redSecondarySlot should be in the same half
|
|
of the shelf for half-height service modules.
|
|
|
|
This object is set to del(2) to delete an entry from the table.
|
|
"
|
|
DEFVAL { del }
|
|
::= { smRedMapEntry 2 }
|
|
|
|
redPrimaryType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
bsc (2),
|
|
aum-T3 (10),
|
|
tim (20),
|
|
frsm-4T1 (30),
|
|
frsm-4E1 (31),
|
|
frsm-hs1 (34),
|
|
frsm-8T1 (35),
|
|
frsm-8E1 (36),
|
|
frsm-hs1b (37),
|
|
ausm-4T1 (40),
|
|
ausm-4E1 (41),
|
|
ausm-8T1 (50),
|
|
ausm-8E1 (51),
|
|
-- AUSM Model B
|
|
ausmB-8T1 (52),
|
|
ausmB-8E1 (53),
|
|
cesm-4T1 (60),
|
|
cesm-4E1 (61),
|
|
imatm-T3T1 (70),
|
|
imatm-E3E1 (71),
|
|
imatmB-T1 (72),
|
|
imatmB-E1 (73),
|
|
|
|
frasm-8T1 (80),
|
|
|
|
cesm-8T1 (90),
|
|
cesm-8E1 (91),
|
|
|
|
-- SM from Netro
|
|
bscsm-2 (100),
|
|
bscsm-4 (101),
|
|
|
|
-- frsm_vhs cards
|
|
frsm-2ct3 (130),
|
|
frsm-2t3 (131),
|
|
frsm-2e3 (132),
|
|
frsm-hs2 (133),
|
|
frsm-2t3b (134),
|
|
frsm-2e3b (135),
|
|
frsm-hs2b-hssi (136),
|
|
frsm-hs2b-12In1 (137),
|
|
|
|
-- cesm-t3e3 cards
|
|
cesm-T3 (140),
|
|
cesm-E3 (141),
|
|
|
|
-- testers
|
|
atmt-8T1 (110),
|
|
atmt-8E1 (111),
|
|
frt-8T1 (120),
|
|
frt-8E1 (121),
|
|
|
|
-- VISM
|
|
vism-8T1 (150),
|
|
vism-8E1 (151),
|
|
|
|
-- reserved for MGX8850 after 1000
|
|
pxm1 (1000),
|
|
pxm1-2t3e3 (1001),
|
|
pxm1-4oc3 (1002),
|
|
pxm1-oc12 (1003),
|
|
|
|
rpm (2000),
|
|
rpm-pr (2001)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object holds the type of the primary card
|
|
Some of the card types are not supported in the table but
|
|
they are defined here for consistency with the shelf card types.
|
|
"
|
|
::= { smRedMapEntry 3 }
|
|
|
|
redPrimaryState OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
nocard (1),
|
|
standby (2),
|
|
active (3),
|
|
failed (4),
|
|
selfTest (5),
|
|
heldInReset (6),
|
|
boot (7),
|
|
mismatch (8),
|
|
unknown (9),
|
|
unusedCoreCardMisMatch (10),
|
|
blocked (11),
|
|
reserved (12),
|
|
-- Hold state applies to PXM during Graceful Upgrade.
|
|
unusedHold (13),
|
|
notResponding (14),
|
|
cardinit (17)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object holds the state of the primary card
|
|
Some of the states are not supported in the table but
|
|
they are defined here for consistency with the cardStates.
|
|
heldInReset, boot and unknown are not supported.
|
|
|
|
Supported values are :
|
|
|
|
nocard (1) : Module not present in the slot
|
|
standby (2) : Module is in 'standby' state
|
|
active (3) : Module is in 'active' state
|
|
failed (4) : Module is in 'failed' state due to some condition
|
|
selfTest(5) : Module is performing selftest
|
|
mismatch(8) : Module is not compatible with the current configuration
|
|
or a wrong type of back-card/line-module is plugged in.
|
|
notResponding(14) : Response from the Service module has become slow
|
|
probably due to overloading of CPU.
|
|
No recovery action is required on user part.
|
|
At present, this state is implemented only for RPM card.
|
|
cardinit(17) : When the physical presence of card has been detected
|
|
but the communication hasn't yet been established between the
|
|
controller card (PXM) and Service Module.
|
|
"
|
|
::= { smRedMapEntry 4 }
|
|
|
|
redSecondarySlotNum OBJECT-TYPE
|
|
SYNTAX INTEGER (0..32)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" This is the slot number of the redundant card for the
|
|
primary card. SecondarySlotNum will be 0 when no secondary
|
|
card covering the primary card. SecondarySlotNum in case
|
|
of MGX8850 shloud be from the same half of the shelf. Like
|
|
if primary card is in the top then secondary card also
|
|
should be in the top and will be covered by top SRM.
|
|
"
|
|
::= { smRedMapEntry 5 }
|
|
|
|
|
|
redSecondaryType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
bsc (2),
|
|
aum-T3 (10),
|
|
tim (20),
|
|
frsm-4T1 (30),
|
|
frsm-4E1 (31),
|
|
frsm-hs1 (34),
|
|
frsm-8T1 (35),
|
|
frsm-8E1 (36),
|
|
frsm-hs1b (37),
|
|
ausm-4T1 (40),
|
|
ausm-4E1 (41),
|
|
ausm-8T1 (50),
|
|
ausm-8E1 (51),
|
|
ausmB-8T1 (52),
|
|
ausmB-8E1 (53),
|
|
cesm-4T1 (60),
|
|
cesm-4E1 (61),
|
|
imatm-T3T1 (70),
|
|
imatm-E3E1 (71),
|
|
imatmB-T1 (72),
|
|
imatmB-E1 (73),
|
|
|
|
frasm-8T1 (80),
|
|
|
|
cesm-8T1 (90),
|
|
cesm-8E1 (91),
|
|
|
|
-- SM from Netro
|
|
bscsm-2 (100),
|
|
bscsm-4 (101),
|
|
|
|
-- frsm_vhs cards
|
|
frsm-2ct3 (130),
|
|
frsm-2t3 (131),
|
|
frsm-2e3 (132),
|
|
frsm-hs2 (133),
|
|
frsm-2t3b (134),
|
|
frsm-2e3b (135),
|
|
frsm-hs2b-hssi (136),
|
|
frsm-hs2b-12In1 (137),
|
|
|
|
-- cesm-t3e3 cards
|
|
cesm-T3 (140),
|
|
cesm-E3 (141),
|
|
|
|
-- testers
|
|
atmt-8T1 (110),
|
|
atmt-8E1 (111),
|
|
frt-8T1 (120),
|
|
frt-8E1 (121),
|
|
|
|
-- VISM
|
|
vism-8T1 (150),
|
|
vism-8E1 (151),
|
|
|
|
-- reserved for MGX8850 after 1000
|
|
pxm1 (1000),
|
|
pxm1-2t3e3 (1001),
|
|
pxm1-4oc3 (1002),
|
|
pxm1-oc12 (1003),
|
|
|
|
rpm (2000),
|
|
rpm-pr (2001)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object holds the type of the redundant card
|
|
Note that redSecondaryType is the same as redPrimaryType
|
|
unless it is changed for a new service module.
|
|
Some of the card types are not supported in the table but
|
|
they are defined here for consistency with the shelf card types.
|
|
"
|
|
::= { smRedMapEntry 6 }
|
|
|
|
redSecondaryState OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
nocard (1),
|
|
standby (2),
|
|
active (3),
|
|
failed (4),
|
|
selfTest (5),
|
|
heldInReset (6),
|
|
boot (7),
|
|
mismatch (8),
|
|
unknown (9),
|
|
unusedCoreCardMisMatch (10),
|
|
blocked (11),
|
|
reserved (12),
|
|
-- Hold state applies to PXM during Graceful Upgrade.
|
|
unusedHold (13),
|
|
notResponding (14),
|
|
cardinit (17)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object holds the state of the secondary card
|
|
|
|
Supported values are :
|
|
|
|
nocard (1) : Module not present in the slot
|
|
standby (2) : Module is in 'standby' state
|
|
active (3) : Module is in 'active' state
|
|
failed (4) : Module is in 'failed' state due to some condition
|
|
selfTest(5) : Module is performing selftest
|
|
mismatch(8) : Module is not compatible with the current configuration
|
|
or a wrong type of back-card/line-module is plugged in.
|
|
notResponding(14) : Response from the Service module has become slow
|
|
probably due to overloading of CPU.
|
|
No recovery action is required on user part.
|
|
At present, this state is implemented only for RPM card.
|
|
cardinit(17) : When the physical presence of card has been detected
|
|
but the communication hasn't yet been established between the
|
|
controller card (PXM) and Service Module.
|
|
"
|
|
::= { smRedMapEntry 7 }
|
|
|
|
redType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yCable (1),
|
|
oneToN (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object describes the type of redundancy.
|
|
The supported values are :
|
|
yCable (1) : 1:1 (y cable) redundancy configuration. In this
|
|
configuration,there is only one module which acts
|
|
as the backup for the other.
|
|
oneToN (2) : 1:N redundancy configuration. In this configuration,
|
|
there is one module(secondary)which acts as the
|
|
backup for other primary modules. There are multiple
|
|
primary modules and one secondary module in this
|
|
configuration. At any point of time, the secondary
|
|
module is backup for only one failed primary
|
|
module. If more than one primary module fails,
|
|
then the failed primary modules are not covered
|
|
by the secondary module.
|
|
"
|
|
::= { smRedMapEntry 8 }
|
|
|
|
redCoveringSlot OBJECT-TYPE
|
|
SYNTAX INTEGER (0..32)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" This is the slot number of the primary card for which
|
|
the secondary card is covering
|
|
Note that redCoveringSlot is set to 0 when the primary
|
|
is not being protected. If this primary card is being
|
|
protected by its redundant card then this object would
|
|
be the primary slot number.
|
|
"
|
|
::= { smRedMapEntry 9 }
|
|
|
|
redFeature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the feature of the primary card.
|
|
"
|
|
::= { smRedMapEntry 10 }
|
|
|
|
redLineModuleType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
lm-DB15-4T1 (16),
|
|
lm-DB15-4E1 (17),
|
|
lm-BNC-4E1 (18),
|
|
lm-DB15-4T1-R(19),
|
|
lm-DB15-4E1-R(20),
|
|
lm-BNC-4E1-R (21),
|
|
lm-RJ48-8T1 (22),
|
|
lm-RJ48-8E1 (23),
|
|
lm-SMB-8E1 (24),
|
|
lm-RJ48-T3T1 (25),
|
|
lm-RJ48-E3E1 (26),
|
|
lm-RJ48-T3E1 (27),
|
|
lm-SMB-E3E1 (28),
|
|
lm-RJ48-E3T1 (29),
|
|
lm-SMB-T3E1 (30),
|
|
lm-T3E3-D (32),
|
|
lm-T3E3-B (33),
|
|
lm-RJ48-8T1-R(48),
|
|
lm-RJ48-8E1-R(49),
|
|
lm-SMB-8E1-R (50),
|
|
-- HSSI/X.21 Added by Suheel
|
|
lm-HS1-4X21 (60),
|
|
lm-HS1-3HSSI (61),
|
|
-- HSSI/X.21
|
|
lm-HS1-4V35 (62),
|
|
|
|
lm-12In1-8s (63)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the line module type for the primary card.
|
|
This object is NOT configurable and it only has the type
|
|
of the current line module that is present in this slot.
|
|
Note that the types that end with a -R are of redundant
|
|
back card type which do not have a connector on the
|
|
its faceplate and they are used for the redundant card
|
|
but they can be plugged into the primary by mistake and
|
|
this object would show its type.
|
|
"
|
|
::= { smRedMapEntry 11 }
|
|
END
|
|
|