#-MIBFILE: cpqpower.mib
|
|
|
|
CPQPOWER-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
DisplayString ::=
|
|
OCTET STRING
|
|
|
|
PhysAddress ::=
|
|
OCTET STRING
|
|
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
interfaces OBJECT IDENTIFIER ::= { mib-2 2 }
|
|
ifTable OBJECT IDENTIFIER ::= { interfaces 2 }
|
|
ifEntry OBJECT IDENTIFIER ::= { ifTable 1 }
|
|
ifIndex OBJECT IDENTIFIER ::= { ifEntry 1 }
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
ifDescr OBJECT IDENTIFIER ::= { ifEntry 2 }
|
|
system OBJECT IDENTIFIER ::= { mib-2 1 }
|
|
sysName OBJECT IDENTIFIER ::= { system 5 }
|
|
sysDescr OBJECT IDENTIFIER ::= { system 1 }
|
|
sysContact OBJECT IDENTIFIER ::= { system 4 }
|
|
sysLocation OBJECT IDENTIFIER ::= { system 6 }
|
|
cpqPower OBJECT IDENTIFIER ::= { compaq 165 }
|
|
|
|
powerDevice OBJECT IDENTIFIER ::= { cpqPower 1 }
|
|
|
|
trapInfo OBJECT IDENTIFIER ::= { powerDevice 1 }
|
|
|
|
managementModuleIdent OBJECT IDENTIFIER ::= { powerDevice 2 }
|
|
|
|
pdu OBJECT IDENTIFIER ::= { cpqPower 2 }
|
|
|
|
pduIdent OBJECT IDENTIFIER ::= { pdu 1 }
|
|
|
|
pduInput OBJECT IDENTIFIER ::= { pdu 2 }
|
|
|
|
pduOutput OBJECT IDENTIFIER ::= { pdu 3 }
|
|
|
|
ups OBJECT IDENTIFIER ::= { cpqPower 3 }
|
|
|
|
upsIdent OBJECT IDENTIFIER ::= { ups 1 }
|
|
|
|
upsBattery OBJECT IDENTIFIER ::= { ups 2 }
|
|
|
|
upsInput OBJECT IDENTIFIER ::= { ups 3 }
|
|
|
|
upsOutput OBJECT IDENTIFIER ::= { ups 4 }
|
|
|
|
upsBypass OBJECT IDENTIFIER ::= { ups 5 }
|
|
|
|
upsEnvironment OBJECT IDENTIFIER ::= { ups 6 }
|
|
|
|
upsTest OBJECT IDENTIFIER ::= { ups 7 }
|
|
|
|
upsControl OBJECT IDENTIFIER ::= { ups 8 }
|
|
|
|
upsConfig OBJECT IDENTIFIER ::= { ups 9 }
|
|
|
|
upsRecep OBJECT IDENTIFIER ::= { ups 10 }
|
|
|
|
upsTopology OBJECT IDENTIFIER ::= { ups 11 }
|
|
|
|
pdr OBJECT IDENTIFIER ::= { cpqPower 4 }
|
|
|
|
pdrIdent OBJECT IDENTIFIER ::= { pdr 1 }
|
|
|
|
pdrPanel OBJECT IDENTIFIER ::= { pdr 2 }
|
|
|
|
pdrBreaker OBJECT IDENTIFIER ::= { pdr 3 }
|
|
|
|
mpdu OBJECT IDENTIFIER ::= { cpqPower 5 }
|
|
|
|
mpduIdent OBJECT IDENTIFIER ::= { mpdu 1 }
|
|
|
|
mpduOutput OBJECT IDENTIFIER ::= { mpdu 2 }
|
|
|
|
mpduDeviceIdent OBJECT IDENTIFIER ::= { mpdu 3 }
|
|
|
|
mpduSmExtBarOutlet OBJECT IDENTIFIER ::= { mpdu 4 }
|
|
|
|
trapCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A number identifying the event for the trap that was sent.
|
|
Mapped unique trap code per unique event to be used by ISEE's
|
|
decoder ring."
|
|
::= { trapInfo 1 }
|
|
|
|
|
|
trapDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A string identifying the event for that last trap that was sent."
|
|
::= { trapInfo 2 }
|
|
|
|
|
|
trapDeviceMgmtUrl OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A string contains the URL for the management software."
|
|
::= { trapInfo 3 }
|
|
|
|
|
|
trapDeviceDetails OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A string details information about the UPS such as SN (serial number),
|
|
PN (part number), and MN (Model Name)."
|
|
::= { trapInfo 4 }
|
|
|
|
|
|
trapDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A string contains the name of the HP Management Module."
|
|
::= { trapInfo 5 }
|
|
|
|
|
|
deviceManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device manufacturer."
|
|
::= { managementModuleIdent 1 }
|
|
|
|
|
|
deviceModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device model."
|
|
::= { managementModuleIdent 2 }
|
|
|
|
|
|
deviceFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device firmware version(s)."
|
|
::= { managementModuleIdent 3 }
|
|
|
|
|
|
deviceHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device hardware version."
|
|
::= { managementModuleIdent 4 }
|
|
|
|
|
|
deviceIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A string identifying the device."
|
|
::= { managementModuleIdent 5 }
|
|
|
|
|
|
devicePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device part number."
|
|
::= { managementModuleIdent 6 }
|
|
|
|
|
|
deviceSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device serial number."
|
|
::= { managementModuleIdent 7 }
|
|
|
|
|
|
deviceMACAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device MAC address."
|
|
::= { managementModuleIdent 8 }
|
|
|
|
|
|
numOfPdu OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of PDUs."
|
|
::= { pduIdent 1 }
|
|
|
|
|
|
pduIdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PduIdentEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Aggregate Object with number of entries equal to
|
|
NumOfPdu and including the PduIdent group."
|
|
::= { pduIdent 2 }
|
|
|
|
|
|
pduIdentEntry OBJECT-TYPE
|
|
SYNTAX PduIdentEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The ident table entry containing the name,
|
|
model, manufacturer, firmware version, part number, etc."
|
|
INDEX { pduIdentIndex }
|
|
|
|
::= { pduIdentTable 1 }
|
|
|
|
pduIdentEntry ::=
|
|
SEQUENCE {
|
|
pduIdentIndex INTEGER,
|
|
pduName DisplayString,
|
|
pduModel DisplayString,
|
|
pduManufacturer DisplayString,
|
|
pduFirmwareVersion DisplayString,
|
|
pduPartNumber DisplayString,
|
|
pduSerialNumber DisplayString,
|
|
pduStatus INTEGER,
|
|
pduControllable INTEGER
|
|
}
|
|
|
|
pduIdentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index for the PduIdentEntry table."
|
|
::= { pduIdentEntry 1 }
|
|
|
|
|
|
pduName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The string identify the device."
|
|
::= { pduIdentEntry 2 }
|
|
|
|
|
|
pduModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device Model."
|
|
::= { pduIdentEntry 3 }
|
|
|
|
|
|
pduManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device Manufacturer Name (e.g. Hewlett-Packard)."
|
|
::= { pduIdentEntry 4 }
|
|
|
|
|
|
pduFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware revision level of the device."
|
|
::= { pduIdentEntry 5 }
|
|
|
|
|
|
pduPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device part number."
|
|
::= { pduIdentEntry 6 }
|
|
|
|
|
|
pduSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The deice serial number."
|
|
::= { pduIdentEntry 7 }
|
|
|
|
|
|
pduStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall status of the device. A value of OK(2) indicates the device is operating normally.
|
|
A value of degraded(3) indicates the device is operating with warning indicators. A value of
|
|
failed(4) indicates the device is operating with critical indicators."
|
|
::= { pduIdentEntry 8 }
|
|
|
|
|
|
pduControllable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes(1),
|
|
no(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This object indicates whether or not the device is controllable."
|
|
::= { pduIdentEntry 9 }
|
|
|
|
|
|
pduInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PduInputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Aggregate Object with number of entries equal to
|
|
NumOfPdu and including the PduInput group."
|
|
::= { pduInput 1 }
|
|
|
|
|
|
pduInputEntry OBJECT-TYPE
|
|
SYNTAX PduInputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The input table entry containing the voltage and
|
|
current for the PDU"
|
|
INDEX { pduInputIndex }
|
|
|
|
::= { pduInputTable 1 }
|
|
|
|
pduInputEntry ::=
|
|
SEQUENCE {
|
|
pduInputIndex INTEGER,
|
|
inputVoltage INTEGER,
|
|
inputCurrent INTEGER
|
|
}
|
|
|
|
pduInputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index for the PduInputEntry table."
|
|
::= { pduInputEntry 1 }
|
|
|
|
|
|
inputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input voltage from the PDU meters in volts."
|
|
::= { pduInputEntry 2 }
|
|
|
|
|
|
inputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input current from the PDU meters in amps."
|
|
::= { pduInputEntry 3 }
|
|
|
|
|
|
pduOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PduOutputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Aggregate Object with number of entries equal to
|
|
NumOfPdu and including the PduInput group."
|
|
::= { pduOutput 1 }
|
|
|
|
|
|
pduOutputEntry OBJECT-TYPE
|
|
SYNTAX PduOutputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The input table entry containing the name,
|
|
heat load, current load, power load, firmware, etc."
|
|
INDEX { pduOutputIndex }
|
|
|
|
::= { pduOutputTable 1 }
|
|
|
|
pduOutputEntry ::=
|
|
SEQUENCE {
|
|
pduOutputIndex INTEGER,
|
|
pduOutputLoad INTEGER,
|
|
pduOutputHeat INTEGER,
|
|
pduOutputPower INTEGER,
|
|
pduOutputNumBreakers INTEGER
|
|
}
|
|
|
|
pduOutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index for the PduOutputEntry table."
|
|
::= { pduOutputEntry 1 }
|
|
|
|
|
|
pduOutputLoad OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device output load in percent of rated capacity. A value of -1 will be
|
|
returned if the heat load is unable to be measured."
|
|
::= { pduOutputEntry 2 }
|
|
|
|
|
|
pduOutputHeat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The total heat load measured on the PDU in BTUs. A value of -1 will be
|
|
returned if the heat load is unable to be measured."
|
|
::= { pduOutputEntry 3 }
|
|
|
|
|
|
pduOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The total power load measured on the PDU in watts. A value of -1 will be
|
|
returned if the power load is unable to be measured."
|
|
::= { pduOutputEntry 4 }
|
|
|
|
|
|
pduOutputNumBreakers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of breakers for the device. This variable indicates the number
|
|
of rows in the breakers table."
|
|
::= { pduOutputEntry 5 }
|
|
|
|
|
|
pduOutputBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PduOutputBreakerEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "List of breaker table entries. The number of entries is given by pduOutputNumBreakers ."
|
|
::= { pduOutput 2 }
|
|
|
|
|
|
pduOutputBreakerEntry OBJECT-TYPE
|
|
SYNTAX PduOutputBreakerEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to an breaker."
|
|
INDEX { pduOutputIndex , breakerIndex }
|
|
|
|
::= { pduOutputBreakerTable 1 }
|
|
|
|
pduOutputBreakerEntry ::=
|
|
SEQUENCE {
|
|
breakerIndex INTEGER,
|
|
breakerVoltage INTEGER,
|
|
breakerCurrent INTEGER,
|
|
breakerPercentLoad INTEGER,
|
|
breakerStatus INTEGER
|
|
}
|
|
|
|
breakerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The breaker identifier."
|
|
::= { pduOutputBreakerEntry 1 }
|
|
|
|
|
|
breakerVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The breaker voltage in volts."
|
|
::= { pduOutputBreakerEntry 2 }
|
|
|
|
|
|
breakerCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The breaker current draw in Amps."
|
|
::= { pduOutputBreakerEntry 3 }
|
|
|
|
|
|
breakerPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The breaker load in percent."
|
|
::= { pduOutputBreakerEntry 4 }
|
|
|
|
|
|
breakerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
overloadWarning(2),
|
|
overloadCritical(3),
|
|
voltageRangeWarning(4),
|
|
voltageRangeCritical(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This object indicates the status of the breaker. A value of normal(1)
|
|
indicates the breaker is operating normally. A value of overloadWarning(2)
|
|
indicates the breaker has an overload warning. A value of overloadCritical(3)
|
|
indicates the breaker is overloaded. A value of voltageRangeWarning(4)
|
|
indicates the breaker voltage is out of tolerance by 10-20%. A value of
|
|
voltageRangeCritical(5) indicates the breaker voltage is out of tolerance
|
|
by more than 20%. Note: Overload status has priority over voltage tolerance
|
|
status."
|
|
::= { pduOutputBreakerEntry 5 }
|
|
|
|
|
|
upsIdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS Manufacturer Name (e.g. Hewlett-Packard)."
|
|
::= { upsIdent 1 }
|
|
|
|
|
|
upsIdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS Model;Part number;Serial number (e.g. HP R5500 XR;204451-B21;B00123456W)."
|
|
::= { upsIdent 2 }
|
|
|
|
|
|
upsIdentSoftwareVersions OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware revision level(s) of the UPS microcontroller(s)."
|
|
::= { upsIdent 3 }
|
|
|
|
|
|
upsIdentOemCode OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A binary code indicating vendor. This should be a ?0x0c? for HP"
|
|
::= { upsIdent 4 }
|
|
|
|
|
|
upsBatTimeRemaining OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery run time in seconds before UPS turns off due
|
|
to low battery."
|
|
::= { upsBattery 1 }
|
|
|
|
|
|
upsBatVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery voltage as reported by the UPS meters."
|
|
::= { upsBattery 2 }
|
|
|
|
|
|
upsBatCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (-2147483648..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery Current as reported by the UPS metering.
|
|
Current is positive when discharging, negative
|
|
when recharging the battery."
|
|
::= { upsBattery 3 }
|
|
|
|
|
|
upsBatCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery percent charge."
|
|
::= { upsBattery 4 }
|
|
|
|
|
|
upsBatteryAbmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
batteryCharging(1),
|
|
batteryDischarging(2),
|
|
batteryFloating(3),
|
|
batteryResting(4),
|
|
unknown(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Gives the status of the Advanced Battery Management;
|
|
batteryFloating(3) status means that the charger is temporarily
|
|
charging the battery to its float voltage; batteryResting(4) is the
|
|
state when the battery is fully charged and none of the other actions
|
|
(charging/discharging/floating) is being done."
|
|
::= { upsBattery 5 }
|
|
|
|
|
|
upsInputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The utility line frequency in tenths of Hz."
|
|
::= { upsInput 1 }
|
|
|
|
|
|
upsInputLineBads OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of times the Input was out of tolerance
|
|
in voltage or frequency."
|
|
::= { upsInput 2 }
|
|
|
|
|
|
upsInputNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "(null)"
|
|
::= { upsInput 3 }
|
|
|
|
|
|
upsInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsInputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Aggregate Object with number of entries equal to
|
|
NumPhases and including the UpsInput group."
|
|
::= { upsInput 4 }
|
|
|
|
|
|
upsInputEntry OBJECT-TYPE
|
|
SYNTAX UpsInputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The input table entry containing the current, voltage, etc."
|
|
INDEX { upsInputPhase }
|
|
|
|
::= { upsInputTable 1 }
|
|
|
|
upsInputEntry ::=
|
|
SEQUENCE {
|
|
upsInputPhase INTEGER,
|
|
upsInputVoltage INTEGER,
|
|
upsInputCurrent INTEGER,
|
|
upsInputWatts INTEGER
|
|
}
|
|
|
|
upsInputPhase OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of the phase. Serves as index for input table."
|
|
::= { upsInputEntry 1 }
|
|
|
|
|
|
upsInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input voltage from the UPS meters in volts."
|
|
::= { upsInputEntry 2 }
|
|
|
|
|
|
upsInputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input current from the UPS meters in amps."
|
|
::= { upsInputEntry 3 }
|
|
|
|
|
|
upsInputWatts OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input real power in watts."
|
|
::= { upsInputEntry 4 }
|
|
|
|
|
|
upsInputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
primaryUtility(3),
|
|
bypassFeed(4),
|
|
secondaryUtility(5),
|
|
generator(6),
|
|
flywheel(7),
|
|
fuelcell(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The present external source of input power. The enumeration
|
|
none(2) indicates that there is no external source of
|
|
power, for example, the UPS is On Battery (an internal source).
|
|
The bypassFeed(4) can only be used when the Bypass source is known
|
|
to be a separate utility feed than the primaryUtility(3)."
|
|
::= { upsInput 5 }
|
|
|
|
|
|
upsOutputLoad OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS output load in percent of rated capacity."
|
|
::= { upsOutput 1 }
|
|
|
|
|
|
upsOutputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured UPS output frequency in tenths of Hz."
|
|
::= { upsOutput 2 }
|
|
|
|
|
|
upsOutputNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of metered output phases, serves as the table
|
|
index."
|
|
::= { upsOutput 3 }
|
|
|
|
|
|
upsOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsOutputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Aggregate Object with number of entries equal to NumPhases
|
|
and including the UpsOutput group."
|
|
::= { upsOutput 4 }
|
|
|
|
|
|
upsOutputEntry OBJECT-TYPE
|
|
SYNTAX UpsOutputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Output Table Entry containing voltage, current, etc."
|
|
INDEX { upsOutputPhase }
|
|
|
|
::= { upsOutputTable 1 }
|
|
|
|
upsOutputEntry ::=
|
|
SEQUENCE {
|
|
upsOutputPhase INTEGER,
|
|
upsOutputVoltage INTEGER,
|
|
upsOutputCurrent INTEGER,
|
|
upsOutputWatts INTEGER
|
|
}
|
|
|
|
upsOutputPhase OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number {1..3} of the output phase."
|
|
::= { upsOutputEntry 1 }
|
|
|
|
|
|
upsOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output voltage from the UPS metering in volts."
|
|
::= { upsOutputEntry 2 }
|
|
|
|
|
|
upsOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured UPS output current in amps."
|
|
::= { upsOutputEntry 3 }
|
|
|
|
|
|
upsOutputWatts OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured real output power in watts."
|
|
::= { upsOutputEntry 4 }
|
|
|
|
|
|
upsOutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7),
|
|
parallelCapacity(8),
|
|
parallelRedundant(9),
|
|
highEfficiencyMode(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { upsOutput 5 }
|
|
|
|
|
|
upsBypassFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The bypass frequency in tenths of Hz."
|
|
::= { upsBypass 1 }
|
|
|
|
|
|
upsBypassNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of lines in the UPS bypass table."
|
|
::= { upsBypass 2 }
|
|
|
|
|
|
upsBypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsBypassEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "(null)"
|
|
::= { upsBypass 3 }
|
|
|
|
|
|
upsBypassEntry OBJECT-TYPE
|
|
SYNTAX UpsBypassEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Entry in the UpsBypassTable."
|
|
INDEX { upsBypassPhase }
|
|
|
|
::= { upsBypassTable 1 }
|
|
|
|
upsBypassEntry ::=
|
|
SEQUENCE {
|
|
upsBypassPhase INTEGER,
|
|
upsBypassVoltage INTEGER
|
|
}
|
|
|
|
upsBypassPhase OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Bypass Phase, index for the table."
|
|
::= { upsBypassEntry 1 }
|
|
|
|
|
|
upsBypassVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured UPS bypass voltage in volts."
|
|
::= { upsBypassEntry 2 }
|
|
|
|
|
|
upsEnvAmbientTemp OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The reading of the ambient temperature in the vicinity of the
|
|
UPS or SNMP agent."
|
|
::= { upsEnvironment 1 }
|
|
|
|
|
|
upsEnvAmbientLowerLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Lower Limit of the ambient temperature; if UpsEnvAmbientTemp
|
|
falls below this value, the UpsAmbientTempBad alarm will occur."
|
|
::= { upsEnvironment 2 }
|
|
|
|
|
|
upsEnvAmbientUpperLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Upper Limit of the ambient temperature; if UpsEnvAmbientTemp
|
|
rises above this value, the UpsAmbientTempBad alarm will occur.
|
|
This value should be greater than UpsEnvAmbientLowerLimit."
|
|
::= { upsEnvironment 3 }
|
|
|
|
|
|
upsEnvAmbientHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The reading of the ambient humidity in the vicinity of the
|
|
UPS or SNMP agent."
|
|
::= { upsEnvironment 4 }
|
|
|
|
|
|
upsEnvRemoteTemp OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The reading of a remote temperature sensor connected to the
|
|
UPS or SNMP agent."
|
|
::= { upsEnvironment 5 }
|
|
|
|
|
|
upsEnvRemoteHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The reading of a remote humidity sensor connected to the
|
|
UPS or SNMP agent."
|
|
::= { upsEnvironment 6 }
|
|
|
|
|
|
upsEnvNumContacts OBJECT-TYPE
|
|
SYNTAX INTEGER (1..1024)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of Contacts in the UpsContactsTable.
|
|
This object indicates the number of rows in the
|
|
UpsContactsTable."
|
|
::= { upsEnvironment 7 }
|
|
|
|
|
|
upsContactsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsContactsTableEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of Contact Sensing table entries.
|
|
The number of entries is given by the value of
|
|
UpsEnvNumContacts."
|
|
::= { upsEnvironment 8 }
|
|
|
|
|
|
upsContactsTableEntry OBJECT-TYPE
|
|
SYNTAX UpsContactsTableEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable
|
|
to a particular Contact input."
|
|
INDEX { upsContactIndex }
|
|
|
|
::= { upsContactsTable 1 }
|
|
|
|
upsContactsTableEntry ::=
|
|
SEQUENCE {
|
|
upsContactIndex INTEGER,
|
|
upsContactType INTEGER,
|
|
upsContactState INTEGER,
|
|
upsContactDescr DisplayString
|
|
}
|
|
|
|
upsContactIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..1024)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Contact identifier; identical to the Contact Number."
|
|
::= { upsContactsTableEntry 1 }
|
|
|
|
|
|
upsContactType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyOpen(1),
|
|
normallyClosed(2),
|
|
anyChange(3),
|
|
notUsed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The normal state for this contact. The 'other'
|
|
state is the Active state for generating the UpstdContactActiveNotice
|
|
trap. If anyChange(3) is selected, then this trap is sent
|
|
any time the contact changes to either Open or Closed.
|
|
No traps are sent if the Contact is set to notUsed(4).
|
|
In many cases, the configuration for Contacts may be done by other
|
|
means, so this object may be read-only."
|
|
::= { upsContactsTableEntry 2 }
|
|
|
|
|
|
upsContactState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
closed(2),
|
|
openWithNotice(3),
|
|
closedWithNotice(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The current state of the Contact input;
|
|
the value is based on the open/closed input state
|
|
and the setting for UpsContactType.
|
|
When entering the openWithNotice(3) and closedWithNotice(4)
|
|
states, no entries added to the UpsAlarmTable, but
|
|
the UpstdContactActiveNotice trap is sent."
|
|
::= { upsContactsTableEntry 3 }
|
|
|
|
|
|
upsContactDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A label identifying the Contact. This object should be
|
|
set by the administrator."
|
|
::= { upsContactsTableEntry 4 }
|
|
|
|
|
|
upsEnvRemoteTempLowerLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Lower Limit of the remote temperature; if UpsEnvRemoteTemp
|
|
falls below this value, the UpsRemoteTempBad alarm will occur."
|
|
::= { upsEnvironment 9 }
|
|
|
|
|
|
upsEnvRemoteTempUpperLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Upper Limit of the remote temperature; if UpsEnvRemoteTemp
|
|
rises above this value, the UpsRemoteTempBad alarm will occur.
|
|
This value should be greater than UpsEnvRemoteTempLowerLimit."
|
|
::= { upsEnvironment 10 }
|
|
|
|
|
|
upsEnvRemoteHumidityLowerLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Lower Limit of the remote humidity reading; if UpsEnvRemoteHumidity
|
|
falls below this value, the UpsRemoteHumidityBad alarm will occur."
|
|
::= { upsEnvironment 11 }
|
|
|
|
|
|
upsEnvRemoteHumidityUpperLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Upper Limit of the remote humidity reading; if UpsEnvRemoteHumidity
|
|
rises above this value, the UpsRemoteHumidityBad alarm will occur.
|
|
This value should be greater than UpsEnvRemoteHumidityLowerLimit."
|
|
::= { upsEnvironment 12 }
|
|
|
|
|
|
upsTestBattery OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
startTest(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this variable to startTest initiates the
|
|
battery test. All other set values are invalid."
|
|
::= { upsTest 1 }
|
|
|
|
|
|
upsTestBatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
passed(2),
|
|
failed(3),
|
|
inProgress(4),
|
|
notSupported(5),
|
|
inhibited(6),
|
|
scheduled(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Reading this enumerated value gives an indication of the
|
|
UPS Battery test status."
|
|
::= { upsTest 2 }
|
|
|
|
|
|
upsTestTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
startTestTrap(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this variable to startTestTrap initiates a TrapTest
|
|
is sent out from HPMM. All other set values are invalid."
|
|
::= { upsTest 3 }
|
|
|
|
|
|
upsControlOutputOffDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this value to other than zero will cause the UPS
|
|
output to turn off after the number of seconds.
|
|
Setting it to 0 will cause an attempt to abort a pending
|
|
shutdown."
|
|
::= { upsControl 1 }
|
|
|
|
|
|
upsControlOutputOnDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this value to other than zero will cause the UPS
|
|
output to turn on after the number of seconds.
|
|
Setting it to 0 will cause an attempt to abort a pending
|
|
startup."
|
|
::= { upsControl 2 }
|
|
|
|
|
|
upsControlOutputOffTrapDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "When UpsControlOutputOffDelay reaches this value, a trap will
|
|
be sent."
|
|
::= { upsControl 3 }
|
|
|
|
|
|
upsControlOutputOnTrapDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "When UpsControlOutputOnDelay reaches this value, a
|
|
UpsOutputOff trap will be sent."
|
|
::= { upsControl 4 }
|
|
|
|
|
|
upsControlToBypassDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this value to other than zero will cause the UPS
|
|
output to go to Bypass after the number of seconds.
|
|
If the Bypass is unavailable, this may cause the UPS
|
|
to not supply power to the load.
|
|
Setting it to 0 will cause an attempt to abort a pending
|
|
shutdown."
|
|
::= { upsControl 5 }
|
|
|
|
|
|
upsLoadShedSecsWithRestart OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this value will cause the UPS output to turn off
|
|
after the set number of seconds, then restart (after a UPS-defined
|
|
'down time') when the utility is again available.
|
|
Unlike UpsControlOutputOffDelay, which might or might not,
|
|
this object always maps to the XCP 0x8A Load Dump & Restart command,
|
|
so the desired shutdown and restart behavior is guaranteed to happen.
|
|
Once set, this command cannot be aborted.
|
|
This is the preferred Control object to use when performing an On
|
|
Battery OS Shutdown."
|
|
::= { upsControl 6 }
|
|
|
|
|
|
upsConfigOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The nominal UPS Output voltage per phase in volts."
|
|
::= { upsConfig 1 }
|
|
|
|
|
|
upsConfigInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The nominal UPS Input voltage per phase in volts."
|
|
::= { upsConfig 2 }
|
|
|
|
|
|
upsConfigOutputWatts OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The nominal UPS available real power output in watts."
|
|
::= { upsConfig 3 }
|
|
|
|
|
|
upsConfigOutputFreq OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The nominal output frequency in tenths of Hz."
|
|
::= { upsConfig 4 }
|
|
|
|
|
|
upsConfigDateAndTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..22))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Date and time information for the UPS. Setting this variable
|
|
will initiate a set UPS date and time to this value. Reading
|
|
this variable will return the UPS time and date. This value
|
|
is not referenced to sysUpTime. It is simply the clock value
|
|
from the UPS real time clock.
|
|
Format is as follows: MM/DD/YYYY:HH:MM:SS."
|
|
::= { upsConfig 5 }
|
|
|
|
|
|
upsConfigLowOutputVoltageLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Lower limit for acceptable Output Voltage, per the UPS
|
|
specifications."
|
|
::= { upsConfig 6 }
|
|
|
|
|
|
upsConfigHighOutputVoltageLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Upper limit for acceptable Output Voltage, per the UPS
|
|
specifications."
|
|
::= { upsConfig 7 }
|
|
|
|
|
|
upsNumReceptacles OBJECT-TYPE
|
|
SYNTAX INTEGER (0..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of independently controllable Receptacles, as described in the
|
|
UpsRecepTable."
|
|
::= { upsRecep 1 }
|
|
|
|
|
|
upsRecepTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsRecepEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Aggregate Object with number of entries equal to
|
|
NumReceptacles and including the UpsRecep group."
|
|
::= { upsRecep 2 }
|
|
|
|
|
|
upsRecepEntry OBJECT-TYPE
|
|
SYNTAX UpsRecepEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Recep table entry, etc."
|
|
INDEX { upsRecepIndex }
|
|
|
|
::= { upsRecepTable 1 }
|
|
|
|
upsRecepEntry ::=
|
|
SEQUENCE {
|
|
upsRecepIndex INTEGER,
|
|
upsRecepStatus INTEGER,
|
|
upsRecepOffDelaySecs INTEGER,
|
|
upsRecepOnDelaySecs INTEGER,
|
|
upsRecepAutoOffDelay INTEGER,
|
|
upsRecepAutoOnDelay INTEGER,
|
|
upsRecepShedSecsWithRestart INTEGER
|
|
}
|
|
|
|
upsRecepIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of the Receptacle. Serves as index for Receptacle table."
|
|
::= { upsRecepEntry 1 }
|
|
|
|
|
|
upsRecepStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
pendingOff(3),
|
|
pendingOn(4),
|
|
unknown(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Recep Status 1=On/Close, 2=Off/Open, 3=On w/Pending Off,
|
|
4=Off w/Pending ON, 5=Unknown."
|
|
::= { upsRecepEntry 2 }
|
|
|
|
|
|
upsRecepOffDelaySecs OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Delay until the Receptacle is turned Off. Setting
|
|
this value to other than -1 will cause the UPS output to
|
|
turn off after the number of seconds (0 is immediately).
|
|
Setting it to -1 will cause an attempt to abort a pending shutdown.
|
|
When this object is set while the UPS is On Battery, it is not necessary
|
|
to set UpsRecepOnDelaySecs, since the outlet will turn back on
|
|
automatically when power is available again."
|
|
::= { upsRecepEntry 3 }
|
|
|
|
|
|
upsRecepOnDelaySecs OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION " The Delay until the Receptacle is turned On. Setting
|
|
this value to other than -1 will cause the UPS output to
|
|
turn on after the number of seconds (0 is immediately).
|
|
Setting it to -1 will cause an attempt to abort a pending restart."
|
|
::= { upsRecepEntry 4 }
|
|
|
|
|
|
upsRecepAutoOffDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The delay after going On Battery until the Receptacle is
|
|
automatically turned Off. A value of -1 means that this Output should
|
|
never be turned Off automatically, but must be turned Off only by command.
|
|
Values from 0 to 30 are valid, but probably innappropriate.
|
|
The AutoOffDelay can be used to prioritize loads in the event of a prolonged
|
|
power outage; less critical loads will turn off earlier to extend battery
|
|
time for the more critical loads. If the utility power is restored before the
|
|
AutoOff delay counts down to 0 on an outlet, that outlet will not turn Off."
|
|
::= { upsRecepEntry 5 }
|
|
|
|
|
|
upsRecepAutoOnDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Seconds delay after the Outlet is signaled to turn On before the Output is
|
|
Automatically turned ON. A value of -1 means that this Output should never
|
|
be turned On automatically, but only when specifically commanded to do so.
|
|
A value of 0 means that the Receptacle should come On immediately
|
|
at power-up or for an On command."
|
|
::= { upsRecepEntry 6 }
|
|
|
|
|
|
upsRecepShedSecsWithRestart OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this value will cause the UPS output to turn off
|
|
after the set number of seconds, then restart (after a UPS-defined
|
|
'down time') when the utility is again available.
|
|
Unlike UpsRecepOffDelaySecs, which might or might not,
|
|
this object always maps to the XCP 0x8A Load Dump & Restart command,
|
|
so the desired shutdown and restart behavior is guaranteed to happen.
|
|
Once set, this command cannot be aborted."
|
|
::= { upsRecepEntry 7 }
|
|
|
|
|
|
upsTopologyType OBJECT-TYPE
|
|
SYNTAX INTEGER (0..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Value which denotes the type of UPS by its power topology. Values are the
|
|
same as those described in the XCP Topology block's Overall Topology field."
|
|
::= { upsTopology 1 }
|
|
|
|
|
|
upsTopoMachineCode OBJECT-TYPE
|
|
SYNTAX INTEGER (0..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "ID Value which denotes the Compaq/HP model of the UPS for software. Values
|
|
are the same as those described in the XCP Configuration block's Machine Code
|
|
field."
|
|
::= { upsTopology 2 }
|
|
|
|
|
|
upsTopoUnitNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Identifies which unit and what type of data is being reported.
|
|
A value of 0 means that this MIB information comes from the top-level system
|
|
view (eg, manifold module or system bypass cabinet reporting total system
|
|
output). Standalone units also use a value of 0, since they are the 'full
|
|
system' view.
|
|
A value of 1 or higher indicates the number of the module in the system
|
|
which is reporting only its own data in the HP MIB objects."
|
|
::= { upsTopology 3 }
|
|
|
|
|
|
upsTopoPowerStrategy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highAlert(1),
|
|
standard(2),
|
|
enableHighEfficiency(3),
|
|
immediateHighEfficiency(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Value which denotes which Power Strategy is currently set for the UPS.
|
|
The values are:
|
|
highAlert(1) - The UPS shall optimize its operating state to maximize its
|
|
power-protection levels. This mode will be held for at most 24 hours.
|
|
standard(2) - Balanced, normal power protection strategy. UPS will not enter
|
|
HE operating mode from this setting.
|
|
enableHighEfficiency(3) - The UPS is enabled to enter HE operating mode to
|
|
optimize its operating state to maximize its efficiency, when
|
|
conditions change to permit it (as determined by the UPS).
|
|
forceHighEfficiency(4) - If this value is permitted to be Set for this UPS,
|
|
and if conditions permit, requires the UPS to enter High Efficiency
|
|
mode now, without delay (for as long as utility conditions permit).
|
|
After successfully set to forceHighEfficiency(4),
|
|
UpsTopoPowerStrategy changes to value enableHighEfficiency(3).
|
|
UpsOutputSource will indicate if the UPS status is actually operating in
|
|
High Efficiency mode."
|
|
::= { upsTopology 4 }
|
|
|
|
|
|
pdrName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The string identify the device."
|
|
::= { pdrIdent 1 }
|
|
|
|
|
|
pdrModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device Model."
|
|
::= { pdrIdent 2 }
|
|
|
|
|
|
pdrManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device Manufacturer Name (e.g. Hewlett-Packard)."
|
|
::= { pdrIdent 3 }
|
|
|
|
|
|
pdrFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware revision level of the device."
|
|
::= { pdrIdent 4 }
|
|
|
|
|
|
pdrPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device part number."
|
|
::= { pdrIdent 5 }
|
|
|
|
|
|
pdrSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDR's serial number."
|
|
::= { pdrIdent 6 }
|
|
|
|
|
|
pdrVARating OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The VA Rating of this PDR (all phases)"
|
|
::= { pdrIdent 7 }
|
|
|
|
|
|
pdrNominalOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The nominal Output Voltage may differ from the nominal
|
|
Input Voltage if the PDR has an input transformer"
|
|
::= { pdrIdent 8 }
|
|
|
|
|
|
pdrNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER (1..3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of phases for this PDR"
|
|
::= { pdrIdent 9 }
|
|
|
|
|
|
pdrNumPanels OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of panels or subfeeds in this PDR"
|
|
::= { pdrIdent 10 }
|
|
|
|
|
|
pdrNumBreakers OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of breakers in this PDR"
|
|
::= { pdrIdent 11 }
|
|
|
|
|
|
pdrPanelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdrPanelEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Aggregate Object with number of entries equal to
|
|
pdrNumPanels"
|
|
::= { pdrPanel 1 }
|
|
|
|
|
|
pdrPanelEntry OBJECT-TYPE
|
|
SYNTAX PdrPanelEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The panel table entry containing all power parameters
|
|
for each panel."
|
|
INDEX { pdrPanelIndex }
|
|
|
|
::= { pdrPanelTable 1 }
|
|
|
|
pdrPanelEntry ::=
|
|
SEQUENCE {
|
|
pdrPanelIndex INTEGER,
|
|
pdrPanelFrequency INTEGER,
|
|
pdrPanelPower INTEGER,
|
|
pdrPanelRatedCurrent INTEGER,
|
|
pdrPanelMonthlyKWH INTEGER,
|
|
pdrPanelYearlyKWH INTEGER,
|
|
pdrPanelTotalKWH INTEGER,
|
|
pdrPanelVoltageA INTEGER,
|
|
pdrPanelVoltageB INTEGER,
|
|
pdrPanelVoltageC INTEGER,
|
|
pdrPanelCurrentA INTEGER,
|
|
pdrPanelCurrentB INTEGER,
|
|
pdrPanelCurrentC INTEGER,
|
|
pdrPanelLoadA INTEGER,
|
|
pdrPanelLoadB INTEGER,
|
|
pdrPanelLoadC INTEGER
|
|
}
|
|
|
|
pdrPanelIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index for the pdrPanelEntry table."
|
|
::= { pdrPanelEntry 1 }
|
|
|
|
|
|
pdrPanelFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The present frequency reading for the panel voltage."
|
|
::= { pdrPanelEntry 2 }
|
|
|
|
|
|
pdrPanelPower OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The present power of the panel."
|
|
::= { pdrPanelEntry 3 }
|
|
|
|
|
|
pdrPanelRatedCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The present rated current of the panel."
|
|
::= { pdrPanelEntry 4 }
|
|
|
|
|
|
pdrPanelMonthlyKWH OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The accumulated KWH for this panel since the beginning of this
|
|
calendar month or since the last reset."
|
|
::= { pdrPanelEntry 5 }
|
|
|
|
|
|
pdrPanelYearlyKWH OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The accumulated KWH for this panel since the beginning of this
|
|
calendar year or since the last reset."
|
|
::= { pdrPanelEntry 6 }
|
|
|
|
|
|
pdrPanelTotalKWH OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The accumulated KWH for this panel since it was put into service
|
|
or since the last reset."
|
|
::= { pdrPanelEntry 7 }
|
|
|
|
|
|
pdrPanelVoltageA OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured panel output voltage."
|
|
::= { pdrPanelEntry 8 }
|
|
|
|
|
|
pdrPanelVoltageB OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured panel output voltage."
|
|
::= { pdrPanelEntry 9 }
|
|
|
|
|
|
pdrPanelVoltageC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured panel output voltage."
|
|
::= { pdrPanelEntry 10 }
|
|
|
|
|
|
pdrPanelCurrentA OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured panel output current."
|
|
::= { pdrPanelEntry 11 }
|
|
|
|
|
|
pdrPanelCurrentB OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured panel output current."
|
|
::= { pdrPanelEntry 12 }
|
|
|
|
|
|
pdrPanelCurrentC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured panel output current."
|
|
::= { pdrPanelEntry 13 }
|
|
|
|
|
|
pdrPanelLoadA OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The percentage of load is the ratio of each output
|
|
current to the rated output current to the panel."
|
|
::= { pdrPanelEntry 14 }
|
|
|
|
|
|
pdrPanelLoadB OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The percentage of load is the ratio of each output
|
|
current to the rated output current to the panel."
|
|
::= { pdrPanelEntry 15 }
|
|
|
|
|
|
pdrPanelLoadC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The percentage of load is the ratio of each output
|
|
current to the rated output current to the panel."
|
|
::= { pdrPanelEntry 16 }
|
|
|
|
|
|
pdrBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdrBreakerEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "List of breaker table entries. The number of entries
|
|
is given by pdrNumBreakers for this panel."
|
|
::= { pdrBreaker 1 }
|
|
|
|
|
|
pdrBreakerEntry OBJECT-TYPE
|
|
SYNTAX PdrBreakerEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a
|
|
particular output breaker of a particular panel."
|
|
INDEX { pdrPanelIndex , pdrBreakerIndex }
|
|
|
|
::= { pdrBreakerTable 1 }
|
|
|
|
pdrBreakerEntry ::=
|
|
SEQUENCE {
|
|
pdrBreakerIndex INTEGER,
|
|
pdrBreakerPanel INTEGER,
|
|
pdrBreakerNumPosition INTEGER,
|
|
pdrBreakerNumPhases INTEGER,
|
|
pdrBreakerNumSequence INTEGER,
|
|
pdrBreakerRatedCurrent INTEGER,
|
|
pdrBreakerMonthlyKWH INTEGER,
|
|
pdrBreakerYearlyKWH INTEGER,
|
|
pdrBreakerTotalKWH INTEGER,
|
|
pdrBreakerCurrent INTEGER,
|
|
pdrBreakerCurrentPercent INTEGER,
|
|
pdrBreakerPower INTEGER,
|
|
pdrBreakerPercentWarning INTEGER,
|
|
pdrBreakerPercentOverload INTEGER
|
|
}
|
|
|
|
pdrBreakerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The index of breakers. 42 breakers in each panel,
|
|
arranged in odd and even columns"
|
|
::= { pdrBreakerEntry 1 }
|
|
|
|
|
|
pdrBreakerPanel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The index of panel that these breakers are installed on."
|
|
::= { pdrBreakerEntry 2 }
|
|
|
|
|
|
pdrBreakerNumPosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The position of this breaker in the panel, 1-phase breaker
|
|
or n-m breaker for 2-phase or n-m-k breaker for 3-phase."
|
|
::= { pdrBreakerEntry 3 }
|
|
|
|
|
|
pdrBreakerNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of phase for this particular breaker."
|
|
::= { pdrBreakerEntry 4 }
|
|
|
|
|
|
pdrBreakerNumSequence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The sequence of this breaker. i.e. 1 for single phase
|
|
1,2 for 2-phase or 1,2,3 for 3-phase."
|
|
::= { pdrBreakerEntry 5 }
|
|
|
|
|
|
pdrBreakerRatedCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The rated current in Amps for this particular breaker."
|
|
::= { pdrBreakerEntry 6 }
|
|
|
|
|
|
pdrBreakerMonthlyKWH OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The accumulated KWH for this breaker since the beginning of this
|
|
calendar month or since the last reset."
|
|
::= { pdrBreakerEntry 7 }
|
|
|
|
|
|
pdrBreakerYearlyKWH OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The accumulated KWH for this breaker since the beginning of this
|
|
calendar year or since the last reset."
|
|
::= { pdrBreakerEntry 8 }
|
|
|
|
|
|
pdrBreakerTotalKWH OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The accumulated KWH for this breaker since it was put into service
|
|
or since the last reset."
|
|
::= { pdrBreakerEntry 9 }
|
|
|
|
|
|
pdrBreakerCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output current for this breaker Current."
|
|
::= { pdrBreakerEntry 10 }
|
|
|
|
|
|
pdrBreakerCurrentPercent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The ratio of output current over rated
|
|
current for each breaker."
|
|
::= { pdrBreakerEntry 11 }
|
|
|
|
|
|
pdrBreakerPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The power for this breaker in Watts."
|
|
::= { pdrBreakerEntry 12 }
|
|
|
|
|
|
pdrBreakerPercentWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The percentage of Warning set for this breaker."
|
|
::= { pdrBreakerEntry 13 }
|
|
|
|
|
|
pdrBreakerPercentOverload OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The percentage of Overload set for this breaker."
|
|
::= { pdrBreakerEntry 14 }
|
|
|
|
|
|
mpduNumMPDU OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of Modular PDUs (Core) detected."
|
|
::= { mpduIdent 1 }
|
|
|
|
|
|
mpduIdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MpduIdentEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Indexed by mpduNumMPDU. So aggregate objects for each entry equal to mpduNumMPDU
|
|
before go to the next entry. i.e if 4 MPDU detected, display 4 indexes, 4
|
|
Manufacturers, 4 Models..., start with 1."
|
|
::= { mpduIdent 2 }
|
|
|
|
|
|
mpduIdentEntry OBJECT-TYPE
|
|
SYNTAX MpduIdentEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The table entry containing the identifications of each MPDU as well
|
|
as names of PDR panel, location of MPDU in a Data Center."
|
|
INDEX { mpduIdentIndex }
|
|
|
|
::= { mpduIdentTable 1 }
|
|
|
|
mpduIdentEntry ::=
|
|
SEQUENCE {
|
|
mpduIdentIndex INTEGER,
|
|
mpduManufacturer DisplayString,
|
|
mpduModel DisplayString,
|
|
mpduName DisplayString,
|
|
mpduFirmwareVersion DisplayString,
|
|
mpduHardwareVersion DisplayString,
|
|
mpduPartNumber DisplayString,
|
|
mpduSerialNumber DisplayString,
|
|
mpduUUID DisplayString,
|
|
mpduIP DisplayString,
|
|
mpduMACAddress DisplayString,
|
|
mpduControlStatus DisplayString,
|
|
mpduRegion DisplayString,
|
|
mpduType DisplayString,
|
|
mpduPowerRating DisplayString,
|
|
mpduInputRating DisplayString,
|
|
mpduInputPlug DisplayString,
|
|
mpduNumBreakers INTEGER,
|
|
mpduNumOutlet INTEGER,
|
|
mpduUHeight INTEGER,
|
|
mpduRedundantStatus DisplayString
|
|
}
|
|
|
|
mpduIdentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index for the MpduIdentEntry table. Start with 1"
|
|
::= { mpduIdentEntry 1 }
|
|
|
|
|
|
mpduManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Core PDU manufacturer."
|
|
::= { mpduIdentEntry 2 }
|
|
|
|
|
|
mpduModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Core PDU model, marketing name."
|
|
::= { mpduIdentEntry 3 }
|
|
|
|
|
|
mpduName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Core PDU name, descriptive name or hostname"
|
|
::= { mpduIdentEntry 4 }
|
|
|
|
|
|
mpduFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Core PDU firmware version(s)."
|
|
::= { mpduIdentEntry 5 }
|
|
|
|
|
|
mpduHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Core PDU hardware version."
|
|
::= { mpduIdentEntry 6 }
|
|
|
|
|
|
mpduPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Core PDU part number."
|
|
::= { mpduIdentEntry 7 }
|
|
|
|
|
|
mpduSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDU external serial number."
|
|
::= { mpduIdentEntry 8 }
|
|
|
|
|
|
mpduUUID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDU's UUID equals PN add SN."
|
|
::= { mpduIdentEntry 9 }
|
|
|
|
|
|
mpduIP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDU's assigned IP."
|
|
::= { mpduIdentEntry 10 }
|
|
|
|
|
|
mpduMACAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Core PDU MAC address."
|
|
::= { mpduIdentEntry 11 }
|
|
|
|
|
|
mpduControlStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Core PDU Control Status: master or slave units."
|
|
::= { mpduIdentEntry 12 }
|
|
|
|
|
|
mpduRegion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDU's Region: NA, Intl, Japan..."
|
|
::= { mpduIdentEntry 13 }
|
|
|
|
|
|
mpduType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDU's Type: Delta, Wye, single, Wye+lowline."
|
|
::= { mpduIdentEntry 14 }
|
|
|
|
|
|
mpduPowerRating OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDU's Power Rating in KVA (Name Plate). Value is presented
|
|
in 1/100 of the KVA. i.e. read 1750 means 17.50 KVA"
|
|
::= { mpduIdentEntry 15 }
|
|
|
|
|
|
mpduInputRating OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDU's Input Current Rating in A (Name Plate)"
|
|
::= { mpduIdentEntry 16 }
|
|
|
|
|
|
mpduInputPlug OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The PDU's Input Plug: IEC60309 516P6,NEMA L15-30P..."
|
|
::= { mpduIdentEntry 17 }
|
|
|
|
|
|
mpduNumBreakers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of breakers used in each MPDU (6 by default)."
|
|
::= { mpduIdentEntry 18 }
|
|
|
|
|
|
mpduNumOutlet OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of outlets of each MPDU (6 by default)."
|
|
::= { mpduIdentEntry 19 }
|
|
|
|
|
|
mpduUHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The MPDU U Height (1U by default)."
|
|
::= { mpduIdentEntry 20 }
|
|
|
|
|
|
mpduRedundantStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status of Core PDU in paired or not: Stand-alone or Redundant."
|
|
::= { mpduIdentEntry 21 }
|
|
|
|
|
|
mpduOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MpduOutputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Indexed by mpduNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU
|
|
multiplies mpduNumOutlet) before go to the next entry. i.e if 4 MPDU detected,
|
|
display 6x4 indexes, 6x4 OutputStatus, 6x4 OutputBreakerRating...start with 1."
|
|
::= { mpduOutput 1 }
|
|
|
|
|
|
mpduOutputEntry OBJECT-TYPE
|
|
SYNTAX MpduOutputEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The output table entry containing the voltage, current, PF,
|
|
percent load, VA, Watts for the Modular PDU."
|
|
INDEX { mpduIdentIndex , mpduOutputIndex }
|
|
|
|
::= { mpduOutputTable 1 }
|
|
|
|
mpduOutputEntry ::=
|
|
SEQUENCE {
|
|
mpduOutputIndex INTEGER,
|
|
mpduOutputStatus DisplayString,
|
|
mpduOutputBreakerRating INTEGER,
|
|
mpduOutputSmartDevice DisplayString,
|
|
mpduOutputPercentLoad INTEGER,
|
|
mpduOutputVoltage INTEGER,
|
|
mpduOutputCurrent INTEGER,
|
|
mpduOutputPowerVA INTEGER,
|
|
mpduOutputPowerWatt INTEGER,
|
|
mpduOutputPowerFactor INTEGER,
|
|
mpduOutputWarningThreshold INTEGER,
|
|
mpduOutputCriticalThreshold INTEGER
|
|
}
|
|
|
|
mpduOutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index for the MpduOutputEntry table."
|
|
::= { mpduOutputEntry 1 }
|
|
|
|
|
|
mpduOutputStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall status of the device: off, on, problem."
|
|
::= { mpduOutputEntry 2 }
|
|
|
|
|
|
mpduOutputBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The rating of each MPDU Output in Ampere."
|
|
::= { mpduOutputEntry 3 }
|
|
|
|
|
|
mpduOutputSmartDevice OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A smart cord device detected: False, True."
|
|
::= { mpduOutputEntry 4 }
|
|
|
|
|
|
mpduOutputPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER (0..200)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The MPDU's each output load in percent of rated capacity. Value is
|
|
presented in 1/10 of the percentage i.e. 125 is 12.5%. A value
|
|
of -1 will be returned if the current is unable to be measured."
|
|
::= { mpduOutputEntry 5 }
|
|
|
|
|
|
mpduOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output voltage from the PDU meters in volts. Value is
|
|
presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value
|
|
of -1 will be returned if the voltage is unable to be measured."
|
|
::= { mpduOutputEntry 6 }
|
|
|
|
|
|
mpduOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output current from the PDU meters in amps. Value is
|
|
presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value
|
|
of -1 will be returned if the current is unable to be measured."
|
|
::= { mpduOutputEntry 7 }
|
|
|
|
|
|
mpduOutputPowerVA OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The total VA load (VI) measured on the PDU in VA. A value
|
|
of -1 will be returned if the power is unable to be calculated."
|
|
::= { mpduOutputEntry 8 }
|
|
|
|
|
|
mpduOutputPowerWatt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The total power load measured on the PDU in Watts. A value
|
|
of -1 will be returned if the power is unable to be calculated."
|
|
::= { mpduOutputEntry 9 }
|
|
|
|
|
|
mpduOutputPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The power factor is presented in 1/100 of the unit i.e.
|
|
98 is 0.98. A value of -1 will be returned if the power factor is unable
|
|
to be measured."
|
|
::= { mpduOutputEntry 10 }
|
|
|
|
|
|
mpduOutputWarningThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Report the User-set threshhold limit for Warning in percentage"
|
|
::= { mpduOutputEntry 11 }
|
|
|
|
|
|
mpduOutputCriticalThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Report the User-set threshhold limit for Critical in percentage"
|
|
::= { mpduOutputEntry 12 }
|
|
|
|
|
|
mpduDeviceIdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MpduDeviceIdentEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Indexed by mpduNumOutlet. So aggregate objects for each entry equal
|
|
to (mpduNumMPDU multiplies mpduNumOutlet) before go to the next entry.
|
|
i.e if 4 MPDU detected, display 6x4 indexes, 6x4 mpduDeviceStatus, 6x4
|
|
DeviceUIDStatus...start with 1."
|
|
::= { mpduDeviceIdent 1 }
|
|
|
|
|
|
mpduDeviceIdentEntry OBJECT-TYPE
|
|
SYNTAX MpduDeviceIdentEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The ident table entry containing the name, model,
|
|
manufacturer, firmware version, part number... for
|
|
each smart device, null value for unknown device."
|
|
INDEX { mpduIdentIndex , mpduDeviceIdentIndex }
|
|
|
|
::= { mpduDeviceIdentTable 1 }
|
|
|
|
mpduDeviceIdentEntry ::=
|
|
SEQUENCE {
|
|
mpduDeviceIdentIndex INTEGER,
|
|
mpduDeviceStatus DisplayString,
|
|
mpduDeviceUIDStatus DisplayString,
|
|
mpduDeviceNumOutlet INTEGER,
|
|
mpduDeviceUHeight INTEGER,
|
|
mpduDevicePowerRating DisplayString,
|
|
mpduDeviceManufacturer DisplayString,
|
|
mpduDeviceType DisplayString,
|
|
mpduDeviceModel DisplayString,
|
|
mpduDeviceName DisplayString,
|
|
mpduDeviceFirmwareVersion DisplayString,
|
|
mpduDeviceHardwareVersion DisplayString,
|
|
mpduDevicePartNumber DisplayString,
|
|
mpduDeviceSerialNumber DisplayString,
|
|
mpduDeviceUUID DisplayString
|
|
}
|
|
|
|
mpduDeviceIdentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index is based on the total number of Smart Extension Bars plus
|
|
smart devices (with smart cord i.e. blades) detected."
|
|
::= { mpduDeviceIdentEntry 1 }
|
|
|
|
|
|
mpduDeviceStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall status of the device: off, on, problem."
|
|
::= { mpduDeviceIdentEntry 2 }
|
|
|
|
|
|
mpduDeviceUIDStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall status of the device UID: off, on, blink."
|
|
::= { mpduDeviceIdentEntry 3 }
|
|
|
|
|
|
mpduDeviceNumOutlet OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of outlets of detected the device. This variable
|
|
indicates the number of rows in the breakers table. Default is 5"
|
|
::= { mpduDeviceIdentEntry 4 }
|
|
|
|
|
|
mpduDeviceUHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The U height of ext bar or device."
|
|
::= { mpduDeviceIdentEntry 5 }
|
|
|
|
|
|
mpduDevicePowerRating OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device's Power Rating in VA. Enter null if not detected."
|
|
::= { mpduDeviceIdentEntry 6 }
|
|
|
|
|
|
mpduDeviceManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device Manufacturer Name (e.g. Hewlett-Packard).
|
|
Enter null if not detected."
|
|
::= { mpduDeviceIdentEntry 7 }
|
|
|
|
|
|
mpduDeviceType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device's Type: Ext Bar, server, or network device..."
|
|
::= { mpduDeviceIdentEntry 8 }
|
|
|
|
|
|
mpduDeviceModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device Model is Managed or Non-managed Ext Bar. Enter null if not detected."
|
|
::= { mpduDeviceIdentEntry 9 }
|
|
|
|
|
|
mpduDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The string identify the Device. i.e. 'BAR#1' (descriptive name)
|
|
Enter null if not detected."
|
|
::= { mpduDeviceIdentEntry 10 }
|
|
|
|
|
|
mpduDeviceFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware revision level of Sm Ext Bar. Enter null if not detected."
|
|
::= { mpduDeviceIdentEntry 11 }
|
|
|
|
|
|
mpduDeviceHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The hardware version of Sm Ext Bar. Enter null if not detected."
|
|
::= { mpduDeviceIdentEntry 12 }
|
|
|
|
|
|
mpduDevicePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device's part number. Enter null if not detected."
|
|
::= { mpduDeviceIdentEntry 13 }
|
|
|
|
|
|
mpduDeviceSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device's serial number. Enter null if not detected"
|
|
::= { mpduDeviceIdentEntry 14 }
|
|
|
|
|
|
mpduDeviceUUID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device's UUID. Enter null if not detected"
|
|
::= { mpduDeviceIdentEntry 15 }
|
|
|
|
|
|
mpduSmExtBarOutletTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MpduSmExtBarOutletEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Indexed by mpduDeviceNumOutlet. So aggregate objects for each entry equal to
|
|
(mpduNumMPDU multiplies mpduNumOutlet multiplies mpduDeviceNumOutlet) before
|
|
go to the next entry. i.e if 4 MPDU detected, display 5x6x4 indexes, 5x6x4
|
|
mpduSmExtBarOutletStatus, 5x6x4 mpduSmExtBarOutletUIDStatus...start with 1."
|
|
::= { mpduSmExtBarOutlet 1 }
|
|
|
|
|
|
mpduSmExtBarOutletEntry OBJECT-TYPE
|
|
SYNTAX MpduSmExtBarOutletEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Entries contain status, measurements for each outlet (no PowerVA)
|
|
Display null if it can't be measured or no device detected."
|
|
INDEX { mpduIdentIndex , mpduOutputIndex, mpduSmExtBarOutletIndex }
|
|
|
|
::= { mpduSmExtBarOutletTable 1 }
|
|
|
|
mpduSmExtBarOutletEntry ::=
|
|
SEQUENCE {
|
|
mpduSmExtBarOutletIndex INTEGER,
|
|
mpduSmExtBarOutletStatus DisplayString,
|
|
mpduSmExtBarOutletUIDStatus DisplayString,
|
|
mpduSmExtBarOutletRating INTEGER,
|
|
mpduSmExtBarOutletVoltage INTEGER,
|
|
mpduSmExtBarOutletCurrent INTEGER,
|
|
mpduSmExtBarOutletPowerWatt INTEGER,
|
|
mpduSmExtBarOutletPowerFactor INTEGER,
|
|
mpduSmExtBarOutletDeviceName DisplayString,
|
|
mpduSmExtBarOutletDeviceUUID DisplayString,
|
|
mpduSmExtBarOutletDeviceProduct DisplayString,
|
|
mpduSmExtBarOutletDeviceIP DisplayString,
|
|
mpduSmExtBarOutletAutoDiscovered INTEGER
|
|
}
|
|
|
|
mpduSmExtBarOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..300)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Index of Smart Extension Bar."
|
|
::= { mpduSmExtBarOutletEntry 1 }
|
|
|
|
|
|
mpduSmExtBarOutletStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall status of the Smart Extension Bar's outlet: off, on, problem..."
|
|
::= { mpduSmExtBarOutletEntry 2 }
|
|
|
|
|
|
mpduSmExtBarOutletUIDStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall status of the Smart Extension Bar's UID: off, on, blink..."
|
|
::= { mpduSmExtBarOutletEntry 3 }
|
|
|
|
|
|
mpduSmExtBarOutletRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Sm Ext Bar Outlet's Rating in Amp. A value of -1 will be returned
|
|
if the stick is unable to detect."
|
|
::= { mpduSmExtBarOutletEntry 4 }
|
|
|
|
|
|
mpduSmExtBarOutletVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The SM Ext Bar voltage in volts. Value is presented 1/10 of the Volt
|
|
i.e. 2098 is 209.8 V. A value of -1 will be returned if the voltage is unable
|
|
to be measured."
|
|
::= { mpduSmExtBarOutletEntry 5 }
|
|
|
|
|
|
mpduSmExtBarOutletCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The SM Ext Bar current draw in Amps. Value is presented in 1/100 of the Ampere
|
|
i.e. 127 is 1.27 A. A value of -1 will be returned if the current is unable
|
|
to be measured."
|
|
::= { mpduSmExtBarOutletEntry 6 }
|
|
|
|
|
|
mpduSmExtBarOutletPowerWatt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Sm Ext Bar's Power measured in Watts. A value of -1 will be returned if the
|
|
power is unable to be measured."
|
|
::= { mpduSmExtBarOutletEntry 7 }
|
|
|
|
|
|
mpduSmExtBarOutletPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The outlet's power factor in 0.01 unit. It is presented in 1/100 of the unit.
|
|
i.e. 98 is 0.98. A value of -1 will be returned if the power factor is unable
|
|
to be measured."
|
|
::= { mpduSmExtBarOutletEntry 8 }
|
|
|
|
|
|
mpduSmExtBarOutletDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device (Blade/Server/Storage) Name that connects to this
|
|
Sm Ext Bar. Enter null if not detected"
|
|
::= { mpduSmExtBarOutletEntry 9 }
|
|
|
|
|
|
mpduSmExtBarOutletDeviceUUID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device (Blade/Server/Storage) UUID that connects to this
|
|
Sm Ext Bar. Enter null if not detected"
|
|
::= { mpduSmExtBarOutletEntry 10 }
|
|
|
|
|
|
mpduSmExtBarOutletDeviceProduct OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device (Blade/Server/Storage) Model that connects to this
|
|
Sm Ext Bar. Enter null if not detected"
|
|
::= { mpduSmExtBarOutletEntry 11 }
|
|
|
|
|
|
mpduSmExtBarOutletDeviceIP OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Device (Blade/Server/Storage) IP of iLO that connects to this
|
|
Sm Ext Bar. Enter null if not detected"
|
|
::= { mpduSmExtBarOutletEntry 12 }
|
|
|
|
|
|
mpduSmExtBarOutletAutoDiscovered OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Boolean values of 0 or 1. 1 means this Sm Ext Bar Outlet is able to get information
|
|
from a blade with smart power supply (auto discovery is enabled)..."
|
|
::= { mpduSmExtBarOutletEntry 13 }
|
|
|
|
|
|
trapCritical TRAP-TYPE
|
|
ENTERPRISE cpqPower
|
|
VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl }
|
|
|
|
--#TYPE "Critical Alarm"
|
|
|
|
--#SEVERITY CRITICAL
|
|
|
|
--#CATEGORY "PowerDevice"
|
|
DESCRIPTION "A critical alarm has occurred. Action: Check the Trap Details for more information."
|
|
::= 1
|
|
|
|
|
|
trapWarning TRAP-TYPE
|
|
ENTERPRISE cpqPower
|
|
VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl }
|
|
|
|
--#TYPE "Warning Alarm"
|
|
|
|
--#SEVERITY MINOR
|
|
|
|
--#CATEGORY "PowerDevice"
|
|
DESCRIPTION "A warning alarm has occurred. Action: Check the Trap Details for more information."
|
|
::= 2
|
|
|
|
|
|
trapInformation TRAP-TYPE
|
|
ENTERPRISE cpqPower
|
|
VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl }
|
|
|
|
--#TYPE "Information Alarm"
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
|
|
--#CATEGORY "PowerDevice"
|
|
DESCRIPTION "An informational alarm has occurred. Action: Check the Trap Details for more information."
|
|
::= 3
|
|
|
|
|
|
trapCleared TRAP-TYPE
|
|
ENTERPRISE cpqPower
|
|
VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl }
|
|
|
|
--#TYPE "Cleared Alarm"
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
|
|
--#CATEGORY "PowerDevice"
|
|
DESCRIPTION "An alarm has cleared. Action: Check the Trap Details for more information."
|
|
::= 4
|
|
|
|
|
|
trapTest TRAP-TYPE
|
|
ENTERPRISE cpqPower
|
|
VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl }
|
|
|
|
--#TYPE "Test Trap"
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
|
|
--#CATEGORY "PowerDevice"
|
|
DESCRIPTION "Test trap sent to a trap receiver to check proper reception of traps"
|
|
::= 5
|
|
|
|
|
|
deviceTrapInitialization TRAP-TYPE
|
|
ENTERPRISE cpqPower
|
|
VARIABLES { sysName, deviceIdentName }
|
|
|
|
--#TYPE "Device Initialization"
|
|
|
|
--#SEVERITY INFORMATIONAL
|
|
|
|
--#CATEGORY "PowerDevice"
|
|
DESCRIPTION "This trap is sent each time a power device is initialized."
|
|
::= 6
|
|
|
|
|
|
END
|
|
|