-- CISCO-WIRELESS-IF-MIB.my: Cisco Wireless Radio Point to Point MIB.
|
|
|
|
-- January 2000, Joseph L Raja
|
|
|
|
-- Copyright (c) 1998-2005 by Cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
|
|
-- ****************************************************************************
|
|
|
|
-- ****************************************************************************
|
|
|
|
|
|
|
|
|
|
CISCO-WIRELESS-IF-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Counter32,
|
|
Integer32,
|
|
Gauge32,
|
|
Counter64,
|
|
NOTIFICATION-TYPE,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString,
|
|
RowStatus,
|
|
TruthValue,
|
|
TimeInterval
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
ifIndex
|
|
FROM IF-MIB
|
|
OwnerString
|
|
FROM RMON-MIB
|
|
CwrRFZeroIndex,
|
|
CwrCwErrorFreeSecond,
|
|
CwrCwErroredSecond,
|
|
CwrCwSeverelyErroredSecond,
|
|
CwrCwConsecutiveSevErrSecond,
|
|
CwrCwDegradedSecond,
|
|
CwrCwDegradedMinute,
|
|
CwrCollectionAction,
|
|
CwrCollectionStatus,
|
|
CwrThreshLimitType,
|
|
CwrRadioSignalAttribute,
|
|
CwrOscState,
|
|
WirelessGauge64
|
|
FROM CISCO-WIRELESS-TC-MIB
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
ciscoWirelessIfMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200601041003Z"
|
|
ORGANIZATION "Cisco Systems Inc."
|
|
CONTACT-INFO
|
|
"Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
E-mail: wireless-nms@cisco.com"
|
|
DESCRIPTION
|
|
"This is the MIB Module for the Cisco Wireless Radio
|
|
Point to Point interface specification.
|
|
|
|
I) Relationship of the Cisco Wireless Radio IF MIB to Interfaces MIB:
|
|
|
|
One instance of the ifEntry exists for each wireless interface.
|
|
The ifType of each such interface will be propWirelessP2P(157).
|
|
|
|
If (at least) one IP address is active on an interface with this
|
|
ifType without the use of any intervening (multiplexing) sub-layer,
|
|
then it will appear in exactly two ifStackTable entries: i.e.,
|
|
for an ifType=propWirelessP2P(157) interface with ifIndex 'x', the
|
|
ifStackTable will contain:
|
|
|
|
ifStackStatus.0.x=active
|
|
ifStackStatus.x.0=active
|
|
|
|
The ifTestTable and ifRcvAddressTable are not supported by this ifType.
|
|
|
|
II) ifEntry for the Wireless MAC Layer:
|
|
|
|
The ifEntry for the wireless MAC Layer supports the following groups in
|
|
the Interfaces MIB :
|
|
a. ifGeneralInformationGroup
|
|
b. ifHCPacketGroup
|
|
|
|
For all those objects where the behavior is as defined in the Interfaces
|
|
MIB, refer to Interfaces MIB for description.
|
|
Special conditions or exceptions are explicitly documented here.
|
|
|
|
IfTable Attribute Comments
|
|
================= ===============================================
|
|
|
|
|
|
ifType, The IANA value of propWirelessP2P(157).
|
|
|
|
ifMtu, Return 1500.
|
|
|
|
ifSpeed, Current configured bandwidth. It can be
|
|
1.5Mbits/sec to 12Mbits/sec.
|
|
|
|
ifPhysAddress, Return 0 length octet string.
|
|
|
|
ifAdminStatus, The administrative status of this interface.
|
|
|
|
ifOperStatus, The current operational status of the
|
|
wireless MAC layer interface.
|
|
|
|
ifLastChange, Refer to the Interfaces MIB.
|
|
|
|
ifInMulticastPkts, Returns 0.
|
|
|
|
ifInBroadcastPkts, Returns 0.
|
|
|
|
ifOutMulticastPkts, Returns 0.
|
|
|
|
ifOutBroadcastPkts, Returns 0.
|
|
|
|
ifHCInMulticastPkts, Not supported.
|
|
|
|
ifHCInBroadcastPkts, Not supported.
|
|
|
|
ifHCOutMulticastPkts, Not supported.
|
|
|
|
ifHCOutBroadcastPkts, Not supported.
|
|
|
|
Glossary
|
|
|
|
The following terms are used in the MIB definitions below.
|
|
|
|
Radio Interface: The interface that provides the wireless
|
|
communication features.
|
|
Radio Link: The bi-directional wireless link that exists between two
|
|
communicating radio.
|
|
Radio PHY: Represents the transmission characteristics of the Radio
|
|
Link.
|
|
RF Unit: The Radio Frequency components and the associated
|
|
antennas.
|
|
ARQ: Automatic Repeat Query.
|
|
|
|
|
|
Cisco Wireless MIB Organization
|
|
|
|
The Cisco Wireless Radio IF MIB provides the following management groups :
|
|
|
|
o. Radio Base Group
|
|
This group contains common information about a radio
|
|
interface . It provides facilities to configure
|
|
attributes such as self-test, acquisition mode, etc.
|
|
It includes configuration information used to set up
|
|
a radio link.
|
|
|
|
o. Radio PHY Quality Group
|
|
This group provides facilities to control/tune the
|
|
transmission and reception quality of the Radio Link.
|
|
The quality of the Radio Link is measured using the
|
|
metrics defined in radio Radio Link metrics group.
|
|
|
|
o. Radio Frequency Resource Group
|
|
This contains information about the Radio frequency
|
|
transmission and reception resources available on the
|
|
system. This group determines the portions of the
|
|
radio spectrum at which the radio subsystem can
|
|
operate.
|
|
This group in conjunction with the radio PHY group
|
|
determine the acutal spectrum that gets used for
|
|
communications.
|
|
|
|
|
|
o. Radio Link Metrics Group
|
|
This group contains metrics to measure the quality of
|
|
radio Link. This includes metrics such as total
|
|
received codeword errors, resync count, errored
|
|
seconds etc.
|
|
|
|
o. Radio Signal Group
|
|
This group contains information about the radio
|
|
signal(s) that were received or attributes of the radio
|
|
signals computed from received signals.
|
|
This group models the real-time data that is collected.
|
|
|
|
The key characteristics are:
|
|
1. The amount of information captured in these parameters
|
|
is large and cannot be modeled as single values.
|
|
|
|
2. They represent real-time information, which cannot be
|
|
polled for as well.
|
|
|
|
3. Hardware captures this information.
|
|
|
|
All the radio signal characteristics are modeled in
|
|
three ways:
|
|
1. Histogram
|
|
2. Timelines
|
|
3. Snapshots
|
|
|
|
For management purposes radio signal characteristics
|
|
are made accessible via:
|
|
1. History Group
|
|
2. Timeline Group
|
|
3. Snapshot Group
|
|
These groups are described below.
|
|
|
|
o. History Group
|
|
This group contains information about the radio system
|
|
characteristics which are inherently modeled as
|
|
historgrams.
|
|
Certain characteristics of the radio system may be
|
|
captured as histograms by the hardware.
|
|
The user may configure these histograms as needed.
|
|
|
|
It exists for the following reasons:
|
|
|
|
1. The amount of information contained in these
|
|
parameters is large and cannot be modeled as single
|
|
values.
|
|
|
|
2. They represent real-time information, which cannot be
|
|
polled for as well.
|
|
|
|
3. Key signal processing information cannot be captured
|
|
by normal SNMP (say 1 sec poll interval) monitoring.
|
|
|
|
4. Hardware captures this information as histograms.
|
|
|
|
5. In wireless environments this is key information that
|
|
can be captured for fault and performance management.
|
|
|
|
o. Timeline Group
|
|
This group contains information about how raw radio
|
|
signal characteristics that may be captured.
|
|
Timelines are normally associated with a threshold
|
|
defined in the threshold group.
|
|
|
|
o. Threshold Group
|
|
This provides provides facilities to define thresholds
|
|
on the raw signal attributes that are processed by the
|
|
hardware. Normally thresholds are used in conjunction
|
|
with Timelines to capture specific radio signal
|
|
behavior.
|
|
|
|
o. Snapshot Group
|
|
This group provides facilities that may be
|
|
used to capture multiple radio signal attributes
|
|
keyed to a single user initiated trigger. Simultaneous
|
|
capture of multiple real-time attributes keyed to
|
|
a single trigger provides indepth information about
|
|
the behavior of the system.
|
|
|
|
o. Test Group
|
|
This provides facilities to establish loopback at
|
|
various points in the hardware for diagnostic
|
|
purposes.
|
|
|
|
o. Antenna Group
|
|
This group provides information about the antenna
|
|
resources installed and available for use.
|
|
|
|
o. Trap Group
|
|
It provides the list of traps that the wireless system
|
|
will generate."
|
|
|
|
REVISION "200601041003Z"
|
|
DESCRIPTION
|
|
"Imported Unsigned32 from SNMPv2-SMI."
|
|
REVISION "200002211500Z"
|
|
DESCRIPTION
|
|
"The initial version of this MIB module."
|
|
::= { ciscoMgmt 136 }
|
|
|
|
-- The Cisco Wireless Radio MIB Tree
|
|
cwrRadioMibObjects OBJECT IDENTIFIER
|
|
::= { ciscoWirelessIfMIB 1 }
|
|
|
|
cwrRadioNotification OBJECT IDENTIFIER
|
|
::= { ciscoWirelessIfMIB 2 }
|
|
|
|
cwrRadioInternal OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 1 }
|
|
|
|
cwrRadioCommon OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 2 }
|
|
|
|
cwrRadioBaseGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 3 }
|
|
|
|
cwrRadioPhyQualityGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 4 }
|
|
|
|
cwrRadioFreqResGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 5 }
|
|
|
|
cwrRadioMetricsGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 6 }
|
|
|
|
cwrRadioHistoryGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 7 }
|
|
|
|
cwrRadioTimelineGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 8 }
|
|
|
|
cwrRadioSnapshotGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 9 }
|
|
|
|
cwrRadioAntennaGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioMibObjects 10 }
|
|
|
|
cwrRadioLatestTrap OBJECT IDENTIFIER
|
|
::= { cwrRadioNotification 1 }
|
|
|
|
cwrRadioDevTraps OBJECT IDENTIFIER
|
|
::= { cwrRadioNotification 2 }
|
|
|
|
cwrRadioThreshTraps OBJECT IDENTIFIER
|
|
::= { cwrRadioNotification 3 }
|
|
|
|
-- Radio Indices.
|
|
cwrRadioNextIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object should be used to generate unique indices when
|
|
creating rows in the cwrRadioHistoryGroup, cwrRadioTimelineGroup,
|
|
and the cwrRadioSnapshotGroup. Every GET request will
|
|
generate a new index.
|
|
The index will not be unique across power cycles of the router."
|
|
::= { cwrRadioCommon 1 }
|
|
|
|
-- The Radio Base Group
|
|
|
|
-- The RadioBaseTable represents the set of radio communication interfaces
|
|
-- and their configuration available on this system.
|
|
-- It contains information that is common to the radio interface.
|
|
cwrRadioBaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrRadioBaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about the radio common to both
|
|
the transmit and receive sides."
|
|
::= { cwrRadioBaseGroup 1 }
|
|
|
|
cwrRadioBaseEntry OBJECT-TYPE
|
|
SYNTAX CwrRadioBaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There exists one such entry for every interface in the
|
|
ifTable which has an ifType of propWirelessP2P(157).
|
|
|
|
Each of these entries are indexed by the value of ifIndex as
|
|
defined in RFC2863."
|
|
INDEX { ifIndex }
|
|
::= { cwrRadioBaseTable 1 }
|
|
|
|
CwrRadioBaseEntry ::= SEQUENCE {
|
|
cwrAcquisitionMode INTEGER,
|
|
cwrSelfTest INTEGER,
|
|
cwrBasePrivacySupport TruthValue,
|
|
cwrTxRfIndex CwrRFZeroIndex,
|
|
cwrRx1RfIndex CwrRFZeroIndex,
|
|
cwrRx2RfIndex CwrRFZeroIndex,
|
|
cwrClockRefExt TruthValue,
|
|
cwrAntAlignment TruthValue
|
|
}
|
|
|
|
cwrAcquisitionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(1),
|
|
slave(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the radio should act as the
|
|
master or as the slave. The slave radio tracks the
|
|
master's frequency."
|
|
::= { cwrRadioBaseEntry 2 }
|
|
|
|
cwrSelfTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
once(2),
|
|
always(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the whether self test should be
|
|
executed and if so whether to do it every time the radio link is
|
|
started. Any changes made to this object will reflected the
|
|
next time the radio link is started.
|
|
|
|
off(1) - Self test never performed.
|
|
once(2) - Self test will be performed the next time the
|
|
radio link is started.
|
|
always(3) - Every time the radio link is started."
|
|
::= { cwrRadioBaseEntry 3 }
|
|
|
|
cwrBasePrivacySupport OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the Baseline Privacy feature is
|
|
available for use on this radio interface. If true then privacy is
|
|
supported."
|
|
::= { cwrRadioBaseEntry 4 }
|
|
|
|
cwrTxRfIndex OBJECT-TYPE
|
|
SYNTAX CwrRFZeroIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the index into the cwrRfTable identifying
|
|
the antenna used for transmission. This index will be 0 if the
|
|
associated transmit antenna is not present."
|
|
::= { cwrRadioBaseEntry 5 }
|
|
|
|
cwrRx1RfIndex OBJECT-TYPE
|
|
SYNTAX CwrRFZeroIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the index of the first receive antenna
|
|
identified by the cwrRfTable. This index will be 0 if the
|
|
associated receive antenna is not present."
|
|
::= { cwrRadioBaseEntry 6 }
|
|
|
|
cwrRx2RfIndex OBJECT-TYPE
|
|
SYNTAX CwrRFZeroIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the index of the second receive antenna
|
|
in the cwrRfTable. This index will be 0 if the associated receive
|
|
antenna is not present."
|
|
::= { cwrRadioBaseEntry 7 }
|
|
|
|
cwrClockRefExt OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this object is set to true(1), the wireless radio uses a
|
|
10MHz external reference clock."
|
|
::= { cwrRadioBaseEntry 8 }
|
|
|
|
cwrAntAlignment OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For normal operation this should be set to false(2). If it set
|
|
true(1), then the radio link is placed in antenna alignment mode.
|
|
In this mode control signals are sent to the RF
|
|
resource which enables the operator to monitor the signal
|
|
received strength at the RF resource. This is mainly used
|
|
for antenna steering i.e. positioning the antenna for the best
|
|
possible signal reception.
|
|
If set to true(1), the radio link's response to rapid changes
|
|
in signal strength may potentially be affected."
|
|
::= { cwrRadioBaseEntry 9 }
|
|
|
|
-- The RadioPhyTable provides facilities to configure the physical
|
|
-- layer characteristics of the radio link.
|
|
cwrRadioPhyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrRadioPhyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about the currently configured
|
|
physical layer. These configuration paramters must match the
|
|
corresponding configuration parameter at the remote end for
|
|
the wireless link to be established."
|
|
::= { cwrRadioBaseGroup 2 }
|
|
|
|
cwrRadioPhyEntry OBJECT-TYPE
|
|
SYNTAX CwrRadioPhyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There exists one such entry for every interface in the ifTable
|
|
which has an ifType of propWirelessP2P(157).
|
|
|
|
Each of these entries are indexed by the value of ifIndex
|
|
as defined in RFC2863."
|
|
INDEX { ifIndex }
|
|
::= { cwrRadioPhyTable 1 }
|
|
|
|
CwrRadioPhyEntry ::= SEQUENCE {
|
|
cwrNumRxAntenna INTEGER,
|
|
cwrBandwidth INTEGER,
|
|
cwrThroughput INTEGER,
|
|
cwrOperatingBand INTEGER,
|
|
cwrTxFrequency INTEGER,
|
|
cwrRxFrequency INTEGER,
|
|
cwrTxPower INTEGER,
|
|
cwrCableLoss INTEGER,
|
|
cwrOpStatus INTEGER,
|
|
cwrCableLossDiversity INTEGER,
|
|
cwrBurstSize INTEGER
|
|
}
|
|
|
|
cwrNumRxAntenna OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of antennas to be used to receive
|
|
the wireless transmissions."
|
|
::= { cwrRadioPhyEntry 1 }
|
|
|
|
cwrBandwidth OBJECT-TYPE
|
|
SYNTAX INTEGER (0..500000000)
|
|
UNITS "Hz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the bandwidth to use. Given bandwidth, the
|
|
actual throughput of the radio link is determined by the
|
|
cwrThroughput setting."
|
|
::= { cwrRadioPhyEntry 2 }
|
|
|
|
cwrThroughput OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
high(1),
|
|
medium(2),
|
|
low(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents an throughput expected of the identified radio
|
|
link. There are 3 possible settings. The settings provide a
|
|
tradeoff between bandwidth and the reliability of the
|
|
radio link. The settings are:
|
|
high(1): For a high throughput. The radio hardware will be
|
|
configured such that it, favors throughput over
|
|
error correction. It may not be able to correct
|
|
all received errors.
|
|
medium(2): This is a balance between high and low.
|
|
low(3): The radio hardware is configured such that it
|
|
trades off throughput for latency and error
|
|
correction. It tries its very
|
|
best to correct errors it detects."
|
|
::= { cwrRadioPhyEntry 3 }
|
|
|
|
cwrOperatingBand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bandUNII(1),
|
|
bandMMDS(2),
|
|
bandOther(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the portion of the frequency spectrum in
|
|
which the radio PHY will operate.
|
|
bandUNII(1) - The U-NII (Unlicensed National Information
|
|
Infrastructure)
|
|
band represents the frequency range 5725.25 to
|
|
5823.75 MHz.
|
|
bandMMDS(2) - The MMDS (Multichannel Multipoint Distribution
|
|
Service)
|
|
band represents the frequency range 2150.75 to
|
|
2688.25 MHz.
|
|
bandOther(3)- For all other frequenciy ranges."
|
|
::= { cwrRadioPhyEntry 4 }
|
|
|
|
cwrTxFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6000000)
|
|
UNITS "10Khz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the center frequency that will be used to
|
|
transmit data over the radio PHY. The specified transmit
|
|
frequency must match the operating band and the capability
|
|
of the RF resource connected to the radio."
|
|
::= { cwrRadioPhyEntry 5 }
|
|
|
|
cwrRxFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6000000)
|
|
UNITS "10Khz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the center frequency that will be used to
|
|
receive transmissions over the radio PHY. The specified receive
|
|
frequency must match the operating band and the capability of the
|
|
RF resource connected to the radio. The transmit frequency at
|
|
the local end must be identical to the receive frequency at the
|
|
remote end for a wireless link to be established."
|
|
::= { cwrRadioPhyEntry 6 }
|
|
|
|
cwrTxPower OBJECT-TYPE
|
|
SYNTAX INTEGER (-80..50)
|
|
UNITS "dBm - decibel milliwatts"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the power that the antenna will transmit.
|
|
The minimum average transmit power for the U-NII or MMDS band is
|
|
0.01 microwatts (-80 dBm). Maximum average transmit power:
|
|
For the MMDS band is 2 Watts i.e. (+33dBm).
|
|
For the U-NII band is 100 milliwatts i.e. (+20dBm).
|
|
The power is specified in dBm."
|
|
::= { cwrRadioPhyEntry 7 }
|
|
|
|
cwrCableLoss OBJECT-TYPE
|
|
SYNTAX INTEGER (0..50)
|
|
UNITS "dB - decibel"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the measured loss in signal power in
|
|
dB that is imposed by the cable connecting the radio to the
|
|
antenna head.
|
|
This value enables the hardware to compensate for the cable
|
|
loss by adjusting the gain appropriately.
|
|
A value of 0 represents no degradation in signal due to the cable.
|
|
This cable loss applies to the transmit antenna identified by
|
|
cwrTxRfIndex."
|
|
::= { cwrRadioPhyEntry 8 }
|
|
|
|
cwrOpStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notOperational(1),
|
|
selftest(2),
|
|
download(3),
|
|
txOnly(4),
|
|
acquiring(5),
|
|
receiveUp(6),
|
|
transmitUp(7),
|
|
linkOperational(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the current state of a radio Link.
|
|
|
|
notOperational(1): The link is not operational.
|
|
selftest(2) : Power on self test in progress
|
|
download(3): Image download is in progress.
|
|
txOnly(4): The radio link will switch to this state if
|
|
the radio link is configured for transmit only.
|
|
acquiring(5): Attempting to sync up with the far end transmitter.
|
|
receiveUp(6): The receive side of the radio link has successfully
|
|
sync'ed up with remote end.
|
|
transmitUp(7): Transmit side of the radio link is up and running.
|
|
linkOperational(8): The radio link is ready for duplex
|
|
communication."
|
|
::= { cwrRadioPhyEntry 9 }
|
|
|
|
cwrCableLossDiversity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..50)
|
|
UNITS "dB - decibel"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the measured loss in signal power
|
|
in dB that is imposed by the cable connecting the radio
|
|
to the antenna head.
|
|
This value enables the hardware to compensate for the cable
|
|
loss by adjusting the gain appropriately.
|
|
A value of 0 represents no degradation in signal due to the cable.
|
|
This cable loss applies to the receive antenna identified by
|
|
cwrRxRf2Index."
|
|
::= { cwrRadioPhyEntry 10 }
|
|
|
|
cwrBurstSize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
small(1),
|
|
medium(2),
|
|
large(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the time duration of the data burst sent
|
|
over the air. The burst size is dependant on the capability of
|
|
the ODU which is represented by the cwrBurstSizeGroup variable
|
|
in the cwrRfTable.
|
|
The user must set this object based on the value of
|
|
cwrBurstSizeGroup in the cwrRfTable.
|
|
|
|
The approximate time duration for each of the burst sizes are:
|
|
small(1): 50 microseconds
|
|
medium(2): 100 microseconds
|
|
large(3): 200 microseconds"
|
|
::= { cwrRadioPhyEntry 11 }
|
|
|
|
-- The Radio PHY Quality Group
|
|
|
|
-- The PhyQualityTable provides facilities to control the quality of the
|
|
-- wireless link i.e. the physical link. The radio PHY layer must be
|
|
-- shutdown before any changes may be made to this table.
|
|
cwrPhyQualityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrPhyQualityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about the radio PHY quality
|
|
control parameters. Note that the parameters in this table are
|
|
automatically determined by the parameters configured in the
|
|
cwrRadioPhyTable. These parameters may further be used to tune
|
|
the characteristics when needed."
|
|
::= { cwrRadioPhyQualityGroup 1 }
|
|
|
|
cwrPhyQualityEntry OBJECT-TYPE
|
|
SYNTAX CwrPhyQualityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There exists one such entry for every interface in the ifTable
|
|
which has an ifType of propWirelessP2P(157).
|
|
|
|
Each of these entries are indexed by the value of ifIndex as
|
|
defined in RFC2863."
|
|
INDEX { ifIndex }
|
|
::= { cwrPhyQualityTable 1 }
|
|
|
|
CwrPhyQualityEntry ::= SEQUENCE {
|
|
cwrArqPctBw INTEGER,
|
|
cwrArqVoiceLatency Integer32,
|
|
cwrArqDataLatency Integer32,
|
|
cwrArqBurstSize Integer32,
|
|
cwrArqTypicalBitRate Integer32,
|
|
cwrArqMinBitRate Integer32,
|
|
cwrArqMaxLatencyJitter Integer32,
|
|
cwrArqReset TruthValue,
|
|
cwrArqOn TruthValue
|
|
}
|
|
|
|
cwrArqPctBw OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10000)
|
|
UNITS "0.01 percent"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the percentage of the total radio PHY
|
|
bandwidth available to the ARQ engine. Some or all of this
|
|
allocated bandwidth is used to when detected errors are
|
|
corrected. The percentage will be
|
|
approximated to the closest value supported by the ARQ engine."
|
|
::= { cwrPhyQualityEntry 1 }
|
|
|
|
cwrArqVoiceLatency OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the latency value for voice data."
|
|
::= { cwrPhyQualityEntry 2 }
|
|
|
|
cwrArqDataLatency OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the expected latency values for data.
|
|
Reducing the latency, provides the ARQ engine less time to correct
|
|
codeword errors. So if latency is reduced sufficiently, the data
|
|
throughput will get effected.
|
|
Also note that the latency values on both ends of the link should
|
|
be kept identical, else the data throughput will be effected."
|
|
::= { cwrPhyQualityEntry 3 }
|
|
|
|
cwrArqBurstSize OBJECT-TYPE
|
|
SYNTAX Integer32 (1..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maximum number of consecutive ARQ
|
|
codewords that will be transmitted. ARQ codewords are
|
|
transmitted for error correction. When an ARQ codeword
|
|
is transmitted, a data codeword cannot be transmitted in
|
|
that time slot, resulting jitter on the received data stream.
|
|
Lower the value of the burst size, lower the peak jitter values."
|
|
::= { cwrPhyQualityEntry 4 }
|
|
|
|
cwrArqTypicalBitRate OBJECT-TYPE
|
|
SYNTAX Integer32 (0..45000000)
|
|
UNITS "bits/sec"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the typical error free bit rate that
|
|
is possible on this link given the current configuration as
|
|
specified in the cwrRadioPhyTable. If the radio channel
|
|
is excessively noisy then the bit rate will be lower
|
|
than this value"
|
|
::= { cwrPhyQualityEntry 5 }
|
|
|
|
cwrArqMinBitRate OBJECT-TYPE
|
|
SYNTAX Integer32 (0..45000000)
|
|
UNITS "bits/sec"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum error free bit rate
|
|
that is supported on this link given the current
|
|
configuration as specified in the
|
|
cwrRadioPhyTable and the settings in this table."
|
|
::= { cwrPhyQualityEntry 6 }
|
|
|
|
cwrArqMaxLatencyJitter OBJECT-TYPE
|
|
SYNTAX Integer32 (1..22000)
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maximum latency jitter introduced
|
|
by the ARQ engine, based on the settings defined
|
|
in this table."
|
|
::= { cwrPhyQualityEntry 7 }
|
|
|
|
cwrArqReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object when set to true will force the PHY quality
|
|
parameters to be reset from the cwrRadioPhyTable.
|
|
Reading this object will always return false. This is useful
|
|
when arbitrary changes to the ARQ parameters have to be reset
|
|
to known consistent valid values."
|
|
::= { cwrPhyQualityEntry 8 }
|
|
|
|
cwrArqOn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object when set to true will enable the Automatic Repeat
|
|
Query subsystem. Disabling the ARQ subsystem disables a major
|
|
error correction mechanism of the radio, due to which an
|
|
operating radio PHY may suffer large performance degradation."
|
|
::= { cwrPhyQualityEntry 9 }
|
|
|
|
-- The Corrected Byte Errors Table
|
|
|
|
-- This table provides information on the number of consecutive
|
|
-- byte errors detected and corrected by the ARQ engine.
|
|
-- The ARQ engine can correct up to 9 consecutive byte errors.
|
|
-- This table provides details on the byte error correction
|
|
-- distribution over time.
|
|
cwrPhyCorrectedBytesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrPhyCorrectedBytesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This provides information on the number of byte
|
|
detected and corrected by the ARQ engine.
|
|
The ARQ engine can correct up to 9 consecutive byte errors.
|
|
This table keeps a count of the number of byte errors corrected
|
|
over time.
|
|
The values in this table are cumulated from link power up."
|
|
::= { cwrRadioPhyQualityGroup 2 }
|
|
|
|
cwrPhyCorrectedBytesEntry OBJECT-TYPE
|
|
SYNTAX CwrPhyCorrectedBytesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There exists one such entry for every interface in the ifTable
|
|
which has an ifType of propWirelessP2P(157).
|
|
|
|
Each of these entries are indexed by the value of ifIndex as
|
|
defined in RFC2863."
|
|
INDEX { ifIndex }
|
|
::= { cwrPhyCorrectedBytesTable 1 }
|
|
|
|
CwrPhyCorrectedBytesEntry ::= SEQUENCE {
|
|
cwrArq1ByteErrs Counter64,
|
|
cwrArq2ByteErrs Counter64,
|
|
cwrArq3ByteErrs Counter64,
|
|
cwrArq4ByteErrs Counter64,
|
|
cwrArq5ByteErrs Counter64,
|
|
cwrArq6ByteErrs Counter64,
|
|
cwrArq7ByteErrs Counter64,
|
|
cwrArq8ByteErrs Counter64,
|
|
cwrArq9ByteErrs Counter64
|
|
}
|
|
|
|
cwrArq1ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of 1 byte errors that were
|
|
corrected since the the radio link reached linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 1 }
|
|
|
|
cwrArq2ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive 2 byte errors
|
|
that were corrected since the the radio link reached
|
|
linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 2 }
|
|
|
|
cwrArq3ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive 3 byte errors
|
|
that were corrected since the the radio link reached
|
|
linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 3 }
|
|
|
|
cwrArq4ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive 4 byte errors
|
|
that were corrected since the the radio link reached
|
|
linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 4 }
|
|
|
|
cwrArq5ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive 5 byte errors
|
|
that were corrected since the the radio link reached
|
|
linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 5 }
|
|
|
|
cwrArq6ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive 6 byte errors
|
|
that were corrected since the the radio link reached
|
|
linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 6 }
|
|
|
|
cwrArq7ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive 7 byte errors
|
|
that were corrected since the the radio link reached
|
|
linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 7 }
|
|
|
|
cwrArq8ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive 8 byte errors
|
|
that were corrected since the the radio link reached
|
|
linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 8 }
|
|
|
|
cwrArq9ByteErrs OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of consecutive 9 byte errors
|
|
that were corrected since the the radio link reached
|
|
linkOperational state."
|
|
::= { cwrPhyCorrectedBytesEntry 9 }
|
|
|
|
-- The Radio Frequency Resource Group.
|
|
|
|
-- The RF Table. This table contains information about the state of the
|
|
-- Radio frequency resources being used by this radio link.
|
|
cwrRfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrRfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about the state of the
|
|
radio frequency resources used by the radio link."
|
|
::= { cwrRadioFreqResGroup 1 }
|
|
|
|
cwrRfEntry OBJECT-TYPE
|
|
SYNTAX CwrRfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrRfTable. This table is largely
|
|
a read only table which provides details on the state of radio
|
|
frequency resources available on the system.
|
|
Physically each RF resource may be realized by one antenna
|
|
and its associated control hardware. A single antenna and its
|
|
associated electronics may act as more than 1 RF resource.
|
|
|
|
When an RF resource acts as both a transmit and receive resource,
|
|
the transmit and receive frequency ranges may overlap.
|
|
|
|
It is indexed by the ifIndex and cwrRfIndex."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrRfIndex
|
|
}
|
|
::= { cwrRfTable 1 }
|
|
|
|
CwrRfEntry ::= SEQUENCE {
|
|
cwrRfIndex Integer32,
|
|
cwrRfResIndex Integer32,
|
|
cwrRFOpMode INTEGER,
|
|
cwrTxFreqRangeMin INTEGER,
|
|
cwrTxFreqRangeMax INTEGER,
|
|
cwrRxFreqRangeMin INTEGER,
|
|
cwrRxFreqRangeMax INTEGER,
|
|
cwrMinTxPower Integer32,
|
|
cwrMaxTxPower Integer32,
|
|
cwrRfTxOscState CwrOscState,
|
|
cwrRfAntIndex Integer32,
|
|
cwrRfRxOscState CwrOscState,
|
|
cwrRfTemperature Integer32,
|
|
cwrRfSupplyVoltageState INTEGER,
|
|
cwrRfStatus INTEGER,
|
|
cwrRfControlChannelStatus INTEGER,
|
|
cwrBurstSizeGroup OCTET STRING
|
|
}
|
|
|
|
cwrRfIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, along with ifIndex, represents the index of
|
|
this entry in the cwrRfTable."
|
|
::= { cwrRfEntry 1 }
|
|
|
|
cwrRfResIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the index into CwrRfEntityTable. This
|
|
index identifies the radio frequency resource."
|
|
REFERENCE " Refer to CwrRfEntityTable in CISCO-WIRELESS-EXP-MIB"
|
|
::= { cwrRfEntry 2 }
|
|
|
|
cwrRFOpMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rxOnly(0),
|
|
txOnly(1),
|
|
rxAndTx(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if this RF resource is being used to either
|
|
receive, transmit, or both."
|
|
::= { cwrRfEntry 3 }
|
|
|
|
cwrTxFreqRangeMin OBJECT-TYPE
|
|
SYNTAX INTEGER (215000..582500)
|
|
UNITS "10 kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the minimum frequency at which this
|
|
RF resource can transmit."
|
|
::= { cwrRfEntry 4 }
|
|
|
|
cwrTxFreqRangeMax OBJECT-TYPE
|
|
SYNTAX INTEGER (215000..582500)
|
|
UNITS "10 kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the maximum frequency at which this
|
|
RF resource can transmit."
|
|
::= { cwrRfEntry 5 }
|
|
|
|
cwrRxFreqRangeMin OBJECT-TYPE
|
|
SYNTAX INTEGER (215000..582500)
|
|
UNITS "10 kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the lowest transmission frequency this RF
|
|
resource can receive."
|
|
::= { cwrRfEntry 6 }
|
|
|
|
cwrRxFreqRangeMax OBJECT-TYPE
|
|
SYNTAX INTEGER (215000..582500)
|
|
UNITS "10 kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the highest transmission frequency that
|
|
this RF resource can receive."
|
|
::= { cwrRfEntry 7 }
|
|
|
|
cwrMinTxPower OBJECT-TYPE
|
|
SYNTAX Integer32 (-80..33)
|
|
UNITS "dBm Decibel milliwatts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the minimum power that the RF subsystem
|
|
can supply the antenna."
|
|
::= { cwrRfEntry 8 }
|
|
|
|
cwrMaxTxPower OBJECT-TYPE
|
|
SYNTAX Integer32 (-80..33)
|
|
UNITS "dBm Decibel milliwatts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the maximum power that the RF subsystem can
|
|
supply the antenna."
|
|
::= { cwrRfEntry 9 }
|
|
|
|
cwrRfTxOscState OBJECT-TYPE
|
|
SYNTAX CwrOscState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the state of the transmit oscillator. The
|
|
oscillator must be in oscillatorOk(1) state for the system to
|
|
function properly."
|
|
::= { cwrRfEntry 10 }
|
|
|
|
cwrRfAntIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the index into the cwrAntennaTable. This
|
|
object may be 0 if the cwrAntennaTable is not available."
|
|
::= { cwrRfEntry 11 }
|
|
|
|
cwrRfRxOscState OBJECT-TYPE
|
|
SYNTAX CwrOscState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the state of the receive oscillator. The
|
|
oscillator must be in oscillatorOk(1) state for the system to
|
|
function properly."
|
|
::= { cwrRfEntry 12 }
|
|
|
|
cwrRfTemperature OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..100)
|
|
UNITS "Degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the current temperature of the RF unit."
|
|
::= { cwrRfEntry 13 }
|
|
|
|
cwrRfSupplyVoltageState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
withinSpecification(1),
|
|
outsideSpecification(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the voltage supply to the RF unit is
|
|
within specifications or not."
|
|
::= { cwrRfEntry 14 }
|
|
|
|
cwrRfStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the RF resource is functioning
|
|
properly or not. If it is functioning properly then it will be
|
|
online(1), else offline(2)."
|
|
::= { cwrRfEntry 15 }
|
|
|
|
cwrRfControlChannelStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
notOk(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each RF resource has an associated control channel.
|
|
The control channel is used to send/receive control information to
|
|
the RF resource. For the RF resouce to operate properly, the control
|
|
channel must be established.
|
|
This object indicates the status of the control channel
|
|
ok(1) - RF resource may be controlled successfully
|
|
notOk(2) - Cannot talk to the RF resource."
|
|
::= { cwrRfEntry 16 }
|
|
|
|
cwrBurstSizeGroup OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (2))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the range or burst sizes supported by the
|
|
ODU. This information is read from the ODU EEPROM. The user may
|
|
set the cwrBurstSize MIB object in the cwrRadioPhyTable based on
|
|
the value of this object."
|
|
::= { cwrRfEntry 17 }
|
|
|
|
-- The Intermediate Frequency Resource table. This table contains
|
|
-- information about the Intermediate Frequency subsystem on the wireless
|
|
-- radio.
|
|
cwrIntFreqTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrIntFreqEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about the state of the
|
|
intermediate frequency subsystem on the wireless radio."
|
|
::= { cwrRadioFreqResGroup 2 }
|
|
|
|
cwrIntFreqEntry OBJECT-TYPE
|
|
SYNTAX CwrIntFreqEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrIntFreqTable.
|
|
This table is largely a read only table which provides details
|
|
on the state of the intermediate frequency subsystem available on
|
|
the wireless radio."
|
|
INDEX { ifIndex }
|
|
::= { cwrIntFreqTable 1 }
|
|
|
|
CwrIntFreqEntry ::= SEQUENCE {
|
|
cwrIfTxOscState CwrOscState,
|
|
cwrIfRxOscState CwrOscState,
|
|
cwrIfRefOscState CwrOscState,
|
|
cwrIfResIndex Integer32,
|
|
cwrIfInpFreq Integer32,
|
|
cwrIfOutFreq Integer32
|
|
}
|
|
|
|
cwrIfTxOscState OBJECT-TYPE
|
|
SYNTAX CwrOscState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the state of the IF transmit oscillator. The
|
|
oscillator must be in oscillatorOk(1) state for the system to
|
|
function properly."
|
|
::= { cwrIntFreqEntry 1 }
|
|
|
|
cwrIfRxOscState OBJECT-TYPE
|
|
SYNTAX CwrOscState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the state of the IF receive oscillator.
|
|
The oscillator must be in oscillatorOk(1) state for the system to
|
|
function properly."
|
|
::= { cwrIntFreqEntry 2 }
|
|
|
|
cwrIfRefOscState OBJECT-TYPE
|
|
SYNTAX CwrOscState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the state of the IF reference oscillator.
|
|
The oscillator must be in oscillatorOk(1) state for the system
|
|
to function properly."
|
|
::= { cwrIntFreqEntry 3 }
|
|
|
|
cwrIfResIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the index into CwrIntFreqEntityTable.
|
|
It identifies the intermediate frequency resource."
|
|
REFERENCE " Refer to CwrIntFreqEntityTable in CISCO-WIRELESS-EXP-MIB"
|
|
::= { cwrIntFreqEntry 4 }
|
|
|
|
cwrIfInpFreq OBJECT-TYPE
|
|
SYNTAX Integer32 (100..10000)
|
|
UNITS "10 kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object represents the IF input frequency."
|
|
::= { cwrIntFreqEntry 5 }
|
|
|
|
cwrIfOutFreq OBJECT-TYPE
|
|
SYNTAX Integer32 (20000..50000)
|
|
UNITS "10 kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object represents the IF output frequency."
|
|
::= { cwrIntFreqEntry 6 }
|
|
|
|
-- The Radio Link Metrics Group
|
|
|
|
|
|
|
|
-- The Link Metrics Group contains information about the quality of the
|
|
-- radio link identified by the ifIndex.
|
|
|
|
-- The the diagram below may be used cross refer to the definitions.
|
|
-- (Note the diagram is just an example):
|
|
|
|
|
|
-- Link Admin-Up Link Admin-Down
|
|
-- |<===================== Link Admin Up Secs ======================>|
|
|
-- | |
|
|
-- | |
|
|
-- V=================================================================V
|
|
-- |<=Sync Loss Secs=>|<=====EFS========>|<=========ES==============>|
|
|
-- | |<=Errs=>|<==DS==>|<==SES==>|
|
|
-- |<======== Avail Secs ==============>|
|
|
|
|
|
|
-- Definitions:
|
|
|
|
-- Link Admin Up Seconds :
|
|
-- Interval in seconds, between the time the link was
|
|
-- administratively configured up and when it was
|
|
-- administratively configured down. It is equal to:
|
|
-- Available Seconds + Unavailable Seconds.
|
|
|
|
-- An Operational Second :
|
|
-- Is defined to be 1 second during which the ends of a radio link are
|
|
-- synchronized and ready for duplex communication.
|
|
-- At this point effective communication may not be possible due to
|
|
-- unacceptably high errors on the link.
|
|
|
|
-- An Operational Hour :
|
|
-- Is 3600 operational seconds.
|
|
|
|
-- Post ARQ Codeword Error:
|
|
-- Also referred to as codeword error in this MIB.
|
|
-- A codeword with errors in it, that could NOT be corrected at all.
|
|
-- A codeword that cannot be corrected is dropped so reducing the
|
|
-- total data throughput.
|
|
|
|
-- Sync Loss Seconds:
|
|
-- The duration in seconds after the link was configured administratively
|
|
-- up but the two ends of the link were not synchronized.
|
|
|
|
-- Error Free Second (CwrCwErrorFreeSecond):
|
|
-- An Codeword Error Free Second (EFS) is defined as 1 second when the
|
|
-- radio link was synchronized and no codeword errors detected on
|
|
-- the link.
|
|
|
|
-- Errored Second (CwrCwErroredSecond):
|
|
-- A Codeword Errored Second (ES) is defined as 1 second when the radio
|
|
-- link was synchronized and 1 or more codeword errors were detected on the
|
|
-- link.
|
|
|
|
-- Degraded Second (CwrCwDegradedSecond):
|
|
-- A Codeword Degraded Second (DS) is defined as a 1 second interval
|
|
-- during which the number of codeword errors was between
|
|
-- cwrLinkLowCwErrThresh and cwrLinkHighCwErrThresh.
|
|
|
|
-- Degraded Minute (CwrCwDegradedMinute):
|
|
-- A Codeword Degraded Minute (DM) is defined as a 60 Codeword Degraded
|
|
-- Seconds.
|
|
|
|
-- Severely Errored Second (CwrCwSeverelyErroredSecond):
|
|
-- A Codeword Severely Errored Second (SES) is defined as 1 second when
|
|
-- the radio link was synchronized and the number of codeword errors
|
|
-- received was greater than the threshold specified by
|
|
-- cwrLinkHighCwErrThresh.
|
|
|
|
-- Consecutively Severely Errored Second (CwrCwConsecutiveSevErrSecond):
|
|
-- A Codeword Consecutively Severely Errored Seconds (CSES) is defined as
|
|
-- the metric that measures the number of times a sequence of Codeword
|
|
-- Severely Errored Seconds(SES) crosses the cwrLinkCSESThresh value.
|
|
-- It is independent of the length of the SES sequence.
|
|
-- In other words this counter is incremented by one and only one
|
|
-- for every such occurrence.
|
|
-- This metric measures the stability of the link i.e. if this count
|
|
-- is high, it implies that the link is oscillating between
|
|
-- usable v/s unusable extremes.
|
|
|
|
-- An Available second:
|
|
-- Is defined to be 1 second during which the link was available for
|
|
-- data transmission. It is equal to:
|
|
-- Error Free Seconds + Errored Seconds - Severely Errored Seconds.
|
|
|
|
-- Unavailable Seconds:
|
|
-- Represent the number of seconds that the user wanted the link to be
|
|
-- availble but was not. It is equal to:
|
|
-- Severely Errored Seconds + Sync Loss Seconds.
|
|
|
|
|
|
-- This group contains the following groups of information:
|
|
|
|
-- o) Link Metric Thresholds. This table provides facilities to establish
|
|
-- thresholds that control the collection of the link metrics.
|
|
|
|
-- o) Cumulative link metrics. This table provides cumulative metrics
|
|
-- about the link since the last reboot of the radio interface.
|
|
|
|
-- o) 24 Hour Metrics. This includes cumulative values of the metrics for
|
|
-- every 24 hours (day) for a duration of atleast 32 days.
|
|
-- The information in table is identical to the information in the
|
|
-- 1 Hour Metrics except that the data has been aggregated over
|
|
-- 24 hours.
|
|
|
|
-- o) 1 Hour Metrics. This includes cumulative values of the metrics for
|
|
-- every hour for a duration of atleast 24 hours. The information in
|
|
-- table is identical to the information in the 1 Minute Metrics except
|
|
-- that the data has been aggregated over 1 hour.
|
|
|
|
-- o) 1 Minute Metrics. This includes cumulative values of the metrics
|
|
-- for every minute for the atleast 60 minutes.
|
|
|
|
-- o) 1 Second Metrics. This table includes updates received from
|
|
-- hardware over the last 1 second. This contains hardware reported
|
|
-- information cumulated over 1 second.
|
|
|
|
|
|
|
|
-- Link Metric Thresholds
|
|
cwrLinkMetricsThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrLinkMetricsThreshEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains threshold values that are the trigger points
|
|
for controlling the collection of the Link Metrics such as
|
|
Codeword Errored Seconds and others."
|
|
::= { cwrRadioMetricsGroup 1 }
|
|
|
|
cwrLinkMetricsThreshEntry OBJECT-TYPE
|
|
SYNTAX CwrLinkMetricsThreshEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There exists one such entry for every interface in the ifTable
|
|
which has an ifType of propWirelessP2P(157).
|
|
|
|
Each of these entries are indexed by the value of ifIndex as
|
|
defined in RFC2863."
|
|
INDEX { ifIndex }
|
|
::= { cwrLinkMetricsThresholdTable 1 }
|
|
|
|
CwrLinkMetricsThreshEntry ::= SEQUENCE {
|
|
cwrLinkCwESThresh Unsigned32,
|
|
cwrLinkLowCwDSThresh Unsigned32,
|
|
cwrLinkHighCwDSThresh Unsigned32,
|
|
cwrLinkCSESThresh Unsigned32,
|
|
cwrLink1HrESAlarmThresh Unsigned32,
|
|
cwrLink1HrSESAlarmThresh Unsigned32,
|
|
cwrLink1HrCSESAlarmThresh Unsigned32,
|
|
cwrLink1HrDCMAlarmThresh Unsigned32,
|
|
cwrLink24HrESAlarmThresh Unsigned32,
|
|
cwrLink24HrSESAlarmThresh Unsigned32,
|
|
cwrLink24HrCSESAlarmThresh Unsigned32,
|
|
cwrLink24HrDCMAlarmThresh Unsigned32
|
|
}
|
|
|
|
cwrLinkCwESThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the number of Codeword Errors detected in a duration of 1
|
|
Operational second, is greater than this value then that second is
|
|
counted as an Errored Second."
|
|
::= { cwrLinkMetricsThreshEntry 1 }
|
|
|
|
cwrLinkLowCwDSThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies low degraded second threshold.
|
|
When the number of codeword errors detected are greater or equal
|
|
than this value and less than cwrLinkHighCwDSThresh
|
|
then that second is counted as a Codeword Degraded Second."
|
|
::= { cwrLinkMetricsThreshEntry 2 }
|
|
|
|
cwrLinkHighCwDSThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies high degraded second threshold.
|
|
When then number of codeword errors detected are greater than
|
|
this value then that second is counted as a Codeword Severely
|
|
Errored Second."
|
|
::= { cwrLinkMetricsThreshEntry 3 }
|
|
|
|
cwrLinkCSESThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the number of severely errored codewords detected
|
|
consecutively in one second equals this threshold value,
|
|
the second is counted as a Consecutively Severely Errored Second."
|
|
::= { cwrLinkMetricsThreshEntry 4 }
|
|
|
|
cwrLink1HrESAlarmThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the one hour Codeword Error Second threshold.
|
|
When the number of Codeword Error Seconds in a 1 Operational Hour
|
|
period exceeds this limit cwrTrapLink1HrThresh trap will be
|
|
generated. Time measurement starts after the first
|
|
operational second."
|
|
::= { cwrLinkMetricsThreshEntry 5 }
|
|
|
|
cwrLink1HrSESAlarmThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the one hour Codeword Severely Errored
|
|
Seconds threshold. When the number of Codeword Severely Errored
|
|
Seconds in a 1 Operational Hour period exceeds this limit
|
|
cwrTrapLink1HrThresh trap will be generated. Time measurement
|
|
starts after the first operational second."
|
|
::= { cwrLinkMetricsThreshEntry 6 }
|
|
|
|
cwrLink1HrCSESAlarmThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the one hour Codeword Consecutively Severely
|
|
Errored Seconds threshold. When the number of Codeword Severely
|
|
Errored Seconds in a 1 Operational Hour period exceeds this limit
|
|
cwrTrapLink1HrThresh trap will be generated.
|
|
Time measurement starts after the first operational second."
|
|
::= { cwrLinkMetricsThreshEntry 7 }
|
|
|
|
cwrLink1HrDCMAlarmThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the one hour Degraded Codeword Minute
|
|
threshold. When the number of Degraded Codeword Minutes in a 1
|
|
Operational Hour period exceeds this limit cwrTrapLink1HrThresh trap
|
|
will be generated.
|
|
Time measurement starts after the first operational second."
|
|
::= { cwrLinkMetricsThreshEntry 8 }
|
|
|
|
cwrLink24HrESAlarmThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the 24 hour Codeword Error Second threshold.
|
|
When the number of Codeword Error Seconds in a 24 Operational Hour
|
|
period exceeds this limit cwrTrapLink24HrThresh trap will be
|
|
generated.
|
|
Time measurement starts after the first operational second."
|
|
::= { cwrLinkMetricsThreshEntry 9 }
|
|
|
|
cwrLink24HrSESAlarmThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the one hour Codeword Severely Errored
|
|
Seconds threshold. When the number of Codeword Severely Errored
|
|
Seconds in a 1 Operational Hour period exceeds this limit
|
|
cwrTrapLink24HrThresh trap will be generated.
|
|
Time measurement starts after the first operational second."
|
|
::= { cwrLinkMetricsThreshEntry 10 }
|
|
|
|
cwrLink24HrCSESAlarmThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the one hour Codeword Consecutively Severely
|
|
Errored Seconds threshold.
|
|
When the number of Codeword Severely Errored
|
|
Seconds in a 1 Operational Hour period exceeds this limit
|
|
cwrTrapLink24HrThresh trap will be generated.
|
|
Time measurement starts after the first operational second."
|
|
::= { cwrLinkMetricsThreshEntry 11 }
|
|
|
|
cwrLink24HrDCMAlarmThresh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the one hour Degraded Codeword Minute
|
|
threshold. When the number of Degraded Codeword Minutes in a 1
|
|
Operational Hour period exceeds this limit cwrTrapLink24HrThresh
|
|
trap will be generated.
|
|
Time measurement starts after the first operational second."
|
|
::= { cwrLinkMetricsThreshEntry 12 }
|
|
|
|
-- Cumulative Link Metrics Table.
|
|
-- This table provides overall metrics on the performance of the link since
|
|
-- the last reboot of the radio interface.
|
|
cwrCumulativeMetricsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrCumulativeMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains metrics used to measure the quality of the
|
|
radio link identified by the ifIndex. The metrics in this table
|
|
are cumulated since the last time the system powered up."
|
|
::= { cwrRadioMetricsGroup 2 }
|
|
|
|
cwrCumulativeMetricsEntry OBJECT-TYPE
|
|
SYNTAX CwrCumulativeMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There exists one such entry for every interface in the ifTable
|
|
which has an ifType of propWirelessP2P(157).
|
|
|
|
Each of these entries are indexed by the value of ifIndex as defined
|
|
in RFC2863."
|
|
INDEX { ifIndex }
|
|
::= { cwrCumulativeMetricsTable 1 }
|
|
|
|
CwrCumulativeMetricsEntry ::= SEQUENCE {
|
|
cwrAvailableSeconds Counter32,
|
|
cwrUnAvailableSeconds Counter32,
|
|
cwrSyncLossSeconds Counter32,
|
|
cwrPctErrorFreeSeconds Gauge32,
|
|
cwrPctErroredSeconds Gauge32,
|
|
cwrPctSeverelyErroredSeconds Gauge32,
|
|
cwrPctAvailSeconds Gauge32,
|
|
cwrPctCwDegradedMinutes Gauge32,
|
|
cwrSyncSuccessCount Counter32,
|
|
cwrSyncFailureCount Counter32,
|
|
cwrManagedSyncLoss Counter32,
|
|
cwrAutomaticSyncLoss Counter32,
|
|
cwrLastSyncSuccessTime TimeInterval,
|
|
cwrLastSyncFailTime TimeInterval,
|
|
cwrEffectivePhyDataRate Gauge32,
|
|
cwrPctEffectivePhyDataRate Gauge32
|
|
}
|
|
|
|
cwrAvailableSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of Available Seconds cumulated
|
|
since the link was powered up. It is equal to:
|
|
Error Free Seconds + Errored Seconds - Severely Errored Seconds."
|
|
::= { cwrCumulativeMetricsEntry 1 }
|
|
|
|
cwrUnAvailableSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of seconds that the link was
|
|
not available for use. It is equal to:
|
|
Severely Errored Seconds + Sync Loss Seconds."
|
|
::= { cwrCumulativeMetricsEntry 2 }
|
|
|
|
cwrSyncLossSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of Link Admin Up Seconds during
|
|
which the radio link was out of sync with the remote end."
|
|
::= { cwrCumulativeMetricsEntry 3 }
|
|
|
|
cwrPctErrorFreeSeconds OBJECT-TYPE
|
|
SYNTAX Gauge32 (1..10000)
|
|
UNITS "0.01 percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the ratio of cumulative Codeword Error Free
|
|
Seconds (EFS) to Link Admin Up seconds, expressed as a percentage."
|
|
::= { cwrCumulativeMetricsEntry 4 }
|
|
|
|
cwrPctErroredSeconds OBJECT-TYPE
|
|
SYNTAX Gauge32 (1..10000)
|
|
UNITS "0.01 percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the ratio of cumulative Codeword Errored
|
|
Seconds (ES) to Link Admin Up seconds, expressed as a percentage."
|
|
::= { cwrCumulativeMetricsEntry 5 }
|
|
|
|
cwrPctSeverelyErroredSeconds OBJECT-TYPE
|
|
SYNTAX Gauge32 (1..10000)
|
|
UNITS "0.01 percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the ratio of cumulative Codeword Severely
|
|
Errored Seconds (SES) to Link Admin Up seconds, expressed as a
|
|
percentage."
|
|
::= { cwrCumulativeMetricsEntry 6 }
|
|
|
|
cwrPctAvailSeconds OBJECT-TYPE
|
|
SYNTAX Gauge32 (1..10000)
|
|
UNITS "0.01 percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the ratio of cumulative Available seconds to
|
|
Link Admin Up seconds, expressed as a percentage."
|
|
::= { cwrCumulativeMetricsEntry 7 }
|
|
|
|
cwrPctCwDegradedMinutes OBJECT-TYPE
|
|
SYNTAX Gauge32 (1..10000)
|
|
UNITS "0.01 percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the ratio of cumulative Codeword Degraded
|
|
Minutes to Link Admin Up seconds, expressed as a percentage."
|
|
::= { cwrCumulativeMetricsEntry 8 }
|
|
|
|
cwrSyncSuccessCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents number of times the radio link successfully
|
|
synchronized with the far end."
|
|
::= { cwrCumulativeMetricsEntry 9 }
|
|
|
|
cwrSyncFailureCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents number of times the link attempted to
|
|
synchronize with the far end but failed to."
|
|
::= { cwrCumulativeMetricsEntry 10 }
|
|
|
|
cwrManagedSyncLoss OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents number of times the radio link layer was
|
|
shutdown by operator intervention or a higher layer protocol."
|
|
::= { cwrCumulativeMetricsEntry 11 }
|
|
|
|
cwrAutomaticSyncLoss OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents number of times the radio link was
|
|
synchronized but lost synchronization with the remote end
|
|
without manual or higher layer protocol layer intervention."
|
|
::= { cwrCumulativeMetricsEntry 12 }
|
|
|
|
cwrLastSyncSuccessTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents elapsed time since the radio link
|
|
successfully synchronized with the remote end."
|
|
::= { cwrCumulativeMetricsEntry 13 }
|
|
|
|
cwrLastSyncFailTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents elapsed time since the radio link
|
|
lost synchronization with the remote end."
|
|
::= { cwrCumulativeMetricsEntry 14 }
|
|
|
|
cwrEffectivePhyDataRate OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the effective data throughput of this link
|
|
while the link was synchronized."
|
|
::= { cwrCumulativeMetricsEntry 15 }
|
|
|
|
cwrPctEffectivePhyDataRate OBJECT-TYPE
|
|
SYNTAX Gauge32 (1..10000)
|
|
UNITS "0.01 percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the ratio of total error free codewords
|
|
received to the total codewords received as a percentage."
|
|
::= { cwrCumulativeMetricsEntry 16 }
|
|
|
|
-- Most Recent 24 Hour Link Metrics Table.
|
|
|
|
-- This table provides metrics on the performance of the link over the
|
|
-- the last 24 Operational Hours.
|
|
cwr24HrMetricsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cwr24HrMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains metrics collected over the duration of
|
|
24 hours.
|
|
This table is updated once every day for 32 days. Therefore, this
|
|
table will have a maximum of 32 entries that provide cumulative
|
|
status of the link, identified by ifIndex."
|
|
::= { cwrRadioMetricsGroup 3 }
|
|
|
|
cwr24HrMetricsEntry OBJECT-TYPE
|
|
SYNTAX Cwr24HrMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwr24HrMetricsTable
|
|
indexed by ifIndex and cwr24HrMetricsIndex.
|
|
|
|
The first entry in the table (cwr24HrMetricsIndex = 1) represents
|
|
the chronologically oldest data available."
|
|
INDEX {
|
|
ifIndex,
|
|
cwr24HrMetricsIndex
|
|
}
|
|
::= { cwr24HrMetricsTable 1 }
|
|
|
|
Cwr24HrMetricsEntry ::= SEQUENCE {
|
|
cwr24HrMetricsIndex Integer32,
|
|
cwr24HrUpdateTime Integer32,
|
|
cwr24HrErrorFreeSeconds CwrCwErrorFreeSecond,
|
|
cwr24HrErroredSeconds CwrCwErroredSecond,
|
|
cwr24HrSevErroredSeconds CwrCwSeverelyErroredSecond,
|
|
cwr24HrConsecSvErrSeconds CwrCwConsecutiveSevErrSecond,
|
|
cwr24HrDegradedMinutes CwrCwDegradedMinute,
|
|
cwr24HrTotalErroredCodewords WirelessGauge64,
|
|
cwr24HrTotalCodewords WirelessGauge64
|
|
}
|
|
|
|
cwr24HrMetricsIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry represents the sum of the metrics from the previous 24
|
|
hour entry + the 24 hour period immdeiately prior to the most
|
|
recent update."
|
|
::= { cwr24HrMetricsEntry 1 }
|
|
|
|
cwr24HrUpdateTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents time in seconds since system power up at
|
|
which time this entry was updated."
|
|
::= { cwr24HrMetricsEntry 2 }
|
|
|
|
cwr24HrErrorFreeSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwErrorFreeSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Error Free Seconds
|
|
(EFS) detected since link power up, captured at cwr24HrUpdateTime."
|
|
::= { cwr24HrMetricsEntry 3 }
|
|
|
|
cwr24HrErroredSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwErroredSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of Codeword Error Seconds (ES)
|
|
detected since link power up, captured at cwr24HrUpdateTime."
|
|
::= { cwr24HrMetricsEntry 4 }
|
|
|
|
cwr24HrSevErroredSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwSeverelyErroredSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of Codeword Severely Error
|
|
Seconds (SES) detected since link power up, captured at
|
|
cwr24HrUpdateTime."
|
|
::= { cwr24HrMetricsEntry 5 }
|
|
|
|
cwr24HrConsecSvErrSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwConsecutiveSevErrSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of Codeword Consecutively
|
|
Severely Error Seconds (CSES) detected since link power up,
|
|
captured at cwr24HrUpdateTime."
|
|
::= { cwr24HrMetricsEntry 6 }
|
|
|
|
cwr24HrDegradedMinutes OBJECT-TYPE
|
|
SYNTAX CwrCwDegradedMinute
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of Codeword Degraded Minutes (DM)
|
|
detected since link power up, captured at cwr24HrUpdateTime."
|
|
::= { cwr24HrMetricsEntry 7 }
|
|
|
|
cwr24HrTotalErroredCodewords OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the total number of errored codewords
|
|
detected since link power up, captured at cwr24HrUpdateTime."
|
|
::= { cwr24HrMetricsEntry 8 }
|
|
|
|
cwr24HrTotalCodewords OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the total number of codewords
|
|
received on this link since link power up, captured at
|
|
cwr24HrUpdateTime."
|
|
::= { cwr24HrMetricsEntry 9 }
|
|
|
|
-- One Hour Link Metrics Table.
|
|
cwr1HrMetricsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cwr1HrMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains metrics collected over the duration of one
|
|
hour.
|
|
This table will have a maximum of 24 entries providing cumulative
|
|
status of the link, identified by ifIndex, over the past 24 hours.
|
|
This table is updated once every hour."
|
|
::= { cwrRadioMetricsGroup 4 }
|
|
|
|
cwr1HrMetricsEntry OBJECT-TYPE
|
|
SYNTAX Cwr1HrMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwr1HrMetricsTable indexed by
|
|
ifIndex and cwr1HrMetricsIndex.
|
|
|
|
The first entry in the table (cwr1HrMetricsIndex = 1) represents
|
|
the chronologically oldest data available."
|
|
INDEX {
|
|
ifIndex,
|
|
cwr1HrMetricsIndex
|
|
}
|
|
::= { cwr1HrMetricsTable 1 }
|
|
|
|
Cwr1HrMetricsEntry ::= SEQUENCE {
|
|
cwr1HrMetricsIndex Integer32,
|
|
cwr1HrUpdateTime Integer32,
|
|
cwr1HrErrorFreeSeconds CwrCwErrorFreeSecond,
|
|
cwr1HrErroredSeconds CwrCwErroredSecond,
|
|
cwr1HrSevErroredSeconds CwrCwSeverelyErroredSecond,
|
|
cwr1HrConsecSvErrSeconds CwrCwConsecutiveSevErrSecond,
|
|
cwr1HrDegradedMinutes CwrCwDegradedMinute,
|
|
cwr1HrErroredCodewords WirelessGauge64,
|
|
cwr1HrTotalCodewords WirelessGauge64
|
|
}
|
|
|
|
cwr1HrMetricsIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..24)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry represents the sum of the metrics from the previous 1
|
|
hour entry + the 1 hour period immdeiately prior to the most
|
|
recent update."
|
|
::= { cwr1HrMetricsEntry 1 }
|
|
|
|
cwr1HrUpdateTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents time in seconds since system power up at
|
|
which time this entry was updated."
|
|
::= { cwr1HrMetricsEntry 2 }
|
|
|
|
cwr1HrErrorFreeSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwErrorFreeSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Error Free Seconds
|
|
(EFS) detected since link power up, captured at cwr1HrUpdateTime."
|
|
::= { cwr1HrMetricsEntry 3 }
|
|
|
|
cwr1HrErroredSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwErroredSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Errored Seconds
|
|
(ES) detected since link power up, captured at cwr1HrUpdateTime."
|
|
::= { cwr1HrMetricsEntry 4 }
|
|
|
|
cwr1HrSevErroredSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwSeverelyErroredSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Severely Errored
|
|
Seconds (SES) detected since link power up, captured at
|
|
cwr1HrUpdateTime."
|
|
::= { cwr1HrMetricsEntry 5 }
|
|
|
|
cwr1HrConsecSvErrSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwConsecutiveSevErrSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Consecutive Severely
|
|
Errored Seconds (CSES) detected since link power up,
|
|
captured at cwr1HrUpdateTime."
|
|
::= { cwr1HrMetricsEntry 6 }
|
|
|
|
cwr1HrDegradedMinutes OBJECT-TYPE
|
|
SYNTAX CwrCwDegradedMinute
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Degraded Minutes
|
|
detected since link power up, captured at cwr1HrUpdateTime."
|
|
::= { cwr1HrMetricsEntry 7 }
|
|
|
|
cwr1HrErroredCodewords OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative errored codewords detected
|
|
since link power up, captured at cwr1HrUpdateTime."
|
|
::= { cwr1HrMetricsEntry 8 }
|
|
|
|
cwr1HrTotalCodewords OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative total received codewords
|
|
detected since link power up, captured at cwr1HrUpdateTime."
|
|
::= { cwr1HrMetricsEntry 9 }
|
|
|
|
-- One Minute Link Metrics Table
|
|
cwr1MinMetricsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cwr1MinMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains metrics collected over the duration of one
|
|
minute.
|
|
This table will have a maximum of 60 entries providing cumulative
|
|
status of the link, identified by ifIndex, over the past 60 minutes.
|
|
This table is updated once every minute."
|
|
::= { cwrRadioMetricsGroup 5 }
|
|
|
|
cwr1MinMetricsEntry OBJECT-TYPE
|
|
SYNTAX Cwr1MinMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwr1MinMetricsTable indexed by
|
|
ifIndex and cwr1MinMetricsIndex.
|
|
|
|
The first entry in the table (cwr1MinMetricsIndex = 1) represents
|
|
the chronologically oldest data available."
|
|
INDEX {
|
|
ifIndex,
|
|
cwr1MinMetricsIndex
|
|
}
|
|
::= { cwr1MinMetricsTable 1 }
|
|
|
|
Cwr1MinMetricsEntry ::= SEQUENCE {
|
|
cwr1MinMetricsIndex Integer32,
|
|
cwr1MinUpdateTime Integer32,
|
|
cwr1MinErrorFreeSeconds CwrCwErrorFreeSecond,
|
|
cwr1MinErroredSeconds CwrCwErroredSecond,
|
|
cwr1MinSevErroredSeconds CwrCwSeverelyErroredSecond,
|
|
cwr1MinConsecSvCwErrSeconds CwrCwConsecutiveSevErrSecond,
|
|
cwr1MinDegradedSeconds CwrCwDegradedSecond,
|
|
cwr1MinErroredCodewords WirelessGauge64,
|
|
cwr1MinCodewords WirelessGauge64
|
|
}
|
|
|
|
cwr1MinMetricsIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry represents the sum of the metrics from the previous 1
|
|
minute entry + the 1 minute period immdeiately prior to the most
|
|
recent update."
|
|
::= { cwr1MinMetricsEntry 1 }
|
|
|
|
cwr1MinUpdateTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents time in seconds since system power up at
|
|
which time this entry was updated."
|
|
::= { cwr1MinMetricsEntry 2 }
|
|
|
|
cwr1MinErrorFreeSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwErrorFreeSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Error Free Seconds
|
|
(EFS) detected since link power up, captured at cwr1MinUpdateTime."
|
|
::= { cwr1MinMetricsEntry 3 }
|
|
|
|
cwr1MinErroredSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwErroredSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Errored Seconds
|
|
(ES) detected since link power up, captured at cwr1MinUpdateTime."
|
|
::= { cwr1MinMetricsEntry 4 }
|
|
|
|
cwr1MinSevErroredSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwSeverelyErroredSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Severely Errored
|
|
Seconds (SES) detected since link power up, captured at
|
|
cwr1MinUpdateTime."
|
|
::= { cwr1MinMetricsEntry 5 }
|
|
|
|
cwr1MinConsecSvCwErrSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwConsecutiveSevErrSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Consecutively
|
|
Severely Errored Seconds (CSES) detected since link power up,
|
|
captured at cwr1MinUpdateTime."
|
|
::= { cwr1MinMetricsEntry 6 }
|
|
|
|
cwr1MinDegradedSeconds OBJECT-TYPE
|
|
SYNTAX CwrCwDegradedSecond
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative Codeword Degraded Seconds
|
|
(DS) detected since link power up, captured at cwr1MinUpdateTime."
|
|
::= { cwr1MinMetricsEntry 7 }
|
|
|
|
cwr1MinErroredCodewords OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative errored codewords detected
|
|
since link power up, captured at cwr1MinUpdateTime."
|
|
::= { cwr1MinMetricsEntry 8 }
|
|
|
|
cwr1MinCodewords OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative total received codewords
|
|
detected since link power up, captured at cwr1MinUpdateTime."
|
|
::= { cwr1MinMetricsEntry 9 }
|
|
|
|
-- One Second Link Metrics
|
|
cwr1SecMetricsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cwr1SecMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains metrics collected over a duration of 1 second.
|
|
The data in this table is derived directly from the hardware.
|
|
|
|
This table will have a maximum of 60 entries providing cumulative
|
|
status of the link, identified by ifIndex, over the past 60 seconds.
|
|
|
|
This table is updated once every second."
|
|
::= { cwrRadioMetricsGroup 6 }
|
|
|
|
cwr1SecMetricsEntry OBJECT-TYPE
|
|
SYNTAX Cwr1SecMetricsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwr1SecMetricsTable indexed by
|
|
ifIndex and cwr1SecMetricsIndex.
|
|
|
|
The first entry in the table (cwr1SecIndex = 1) represents the
|
|
chronologically oldest data available."
|
|
INDEX {
|
|
ifIndex,
|
|
cwr1SecIndex
|
|
}
|
|
::= { cwr1SecMetricsTable 1 }
|
|
|
|
Cwr1SecMetricsEntry ::= SEQUENCE {
|
|
cwr1SecIndex Integer32,
|
|
cwr1SecUpdateTime Integer32,
|
|
cwr1SecRxCodewords WirelessGauge64,
|
|
cwr1SecRSCodewordErrors WirelessGauge64,
|
|
cwr1SecArqCodewordErrors Gauge32,
|
|
cwr1SecRxRrCount Gauge32,
|
|
cwr1SecRxRrEventCount Gauge32,
|
|
cwr1SecTxArqCount Gauge32,
|
|
cwr1SecTxArqEventCount Gauge32,
|
|
cwr1SecCorrectedSyncByteErrs Gauge32,
|
|
cwr1SecConsecutiveCwErrs Gauge32,
|
|
cwr1SecPostARQGoodCodewords WirelessGauge64
|
|
}
|
|
|
|
cwr1SecIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry represents the sum of the metrics from the previous
|
|
1 second entry + the 1 second period immdeiately prior to the
|
|
most recent update."
|
|
::= { cwr1SecMetricsEntry 1 }
|
|
|
|
cwr1SecUpdateTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents time in seconds since system power up at
|
|
which time this entry was updated."
|
|
::= { cwr1SecMetricsEntry 2 }
|
|
|
|
cwr1SecRxCodewords OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative total number of codewords
|
|
received by this radio link at the time this entry was updated."
|
|
::= { cwr1SecMetricsEntry 3 }
|
|
|
|
cwr1SecRSCodewordErrors OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative uncorrectable codewords
|
|
emitted by the Reed-Solomon error correction engine at the time
|
|
this entry was updated. This is also called Pre ARQ codeword error."
|
|
::= { cwr1SecMetricsEntry 4 }
|
|
|
|
cwr1SecArqCodewordErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative number of uncorrectable
|
|
codewords consumed by the Automatic Repeat Query error correction
|
|
engine at the time this entry was updated. This is also called as
|
|
Post ARQ codeword error."
|
|
::= { cwr1SecMetricsEntry 5 }
|
|
|
|
cwr1SecRxRrCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the cumulative number of unique RR's (Retransmit
|
|
Requests) received (from the remote end) at the time this entry was
|
|
updated.
|
|
The remote end issues a Retransmit Request if it receives an
|
|
uncorrectable codeword."
|
|
::= { cwr1SecMetricsEntry 6 }
|
|
|
|
cwr1SecRxRrEventCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative number of RRs
|
|
(Retransmit Requests) that were serviced at the time this entry was
|
|
updated."
|
|
::= { cwr1SecMetricsEntry 7 }
|
|
|
|
cwr1SecTxArqCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents cumulative number of unique ARQ's that
|
|
were received by the transmit side of the local end at the time
|
|
this entry was updated.
|
|
|
|
This provides an indication of how error free the transmisisons of
|
|
the local end of the link are from the the remote end's
|
|
perspective."
|
|
::= { cwr1SecMetricsEntry 8 }
|
|
|
|
cwr1SecTxArqEventCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents cumulative number of ARQ's that were
|
|
serviced at the time this entry was updated.
|
|
|
|
A serviced ARQ results in a re-transmitted codeword."
|
|
::= { cwr1SecMetricsEntry 9 }
|
|
|
|
cwr1SecCorrectedSyncByteErrs OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative number of corrected sync byte
|
|
errors, at the time this entry was updated."
|
|
::= { cwr1SecMetricsEntry 10 }
|
|
|
|
cwr1SecConsecutiveCwErrs OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the size of the larget block of consecutive
|
|
codeword errors received since this entry was last updated."
|
|
::= { cwr1SecMetricsEntry 11 }
|
|
|
|
cwr1SecPostARQGoodCodewords OBJECT-TYPE
|
|
SYNTAX WirelessGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the cumulative number of error free
|
|
codewords emitted by the Automatic Repeat Query error correction
|
|
engine at the time this entry was updated. Also called as
|
|
Post ARQ good codewords."
|
|
::= { cwr1SecMetricsEntry 12 }
|
|
|
|
-- Radio History Group. This group is optional.
|
|
|
|
|
|
-- The Histogram Table. This table contains information about the set of
|
|
-- histograms that the hardware can be programmed to maintain.
|
|
|
|
-- These histograms are generated as follows :
|
|
-- Radio signal data is sampled.
|
|
-- Occurrences of values of the radio signal data is counted.
|
|
-- This count is maintained as discrete sets. Each set represented by one bin.
|
|
|
|
-- Note that the raw radio signal data is not stored in the bins. It is the
|
|
-- count of the occurrence of the radio signal sample that gets stored.
|
|
cwrHistCtrlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrHistCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about histograms configured in
|
|
hardware. When data is collected it will be stored in histogram
|
|
bins as follows:
|
|
All values (X < cwrStartBinValue) will be kept in the first
|
|
histogram bin.
|
|
Subsequent values will be distributed in the bins based on the
|
|
cwrBinDelta. Last bin, will contain all values
|
|
(X > (cwrStartBinValue + (cwrNumBins - 2) * cwrBinDelta)),
|
|
i.e. any value that is greater than that may be stored in the
|
|
last bin."
|
|
::= { cwrRadioHistoryGroup 1 }
|
|
|
|
cwrHistCtrlEntry OBJECT-TYPE
|
|
SYNTAX CwrHistCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrHistogramTable.
|
|
It is indexed by the ifIndex, cwrHistIndex."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrHistIndex
|
|
}
|
|
::= { cwrHistCtrlTable 1 }
|
|
|
|
CwrHistCtrlEntry ::= SEQUENCE {
|
|
cwrHistIndex Integer32,
|
|
cwrHistClass CwrRadioSignalAttribute,
|
|
cwrRfResourceId CwrRFZeroIndex,
|
|
cwrDspNumber INTEGER,
|
|
cwrStartBinValue Integer32,
|
|
cwrBinDelta Integer32,
|
|
cwrNumHistBins Integer32,
|
|
cwrUpdateRate Integer32,
|
|
cwrCollDuration Integer32,
|
|
cwrOwnerId OwnerString,
|
|
cwrHistBitShift INTEGER,
|
|
cwrHistToneSelection INTEGER,
|
|
cwrHistToneValue Integer32,
|
|
cwrHistAction CwrCollectionAction,
|
|
cwrHistStatus CwrCollectionStatus,
|
|
cwrHistRowStatus RowStatus,
|
|
cwrHistPeriodicSum TruthValue
|
|
}
|
|
|
|
cwrHistIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, along with ifIndex, is the index into this table
|
|
and represents one entry in the table. The entry in this table
|
|
for which cwrHistIndex = x is associated with the entry in
|
|
cwrHistSummaryTable and the entry in cwrHistDataTable for
|
|
which the index variable in those tables has the same value, x."
|
|
::= { cwrHistCtrlEntry 1 }
|
|
|
|
cwrHistClass OBJECT-TYPE
|
|
SYNTAX CwrRadioSignalAttribute
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the attribute that is being histogrammed."
|
|
::= { cwrHistCtrlEntry 2 }
|
|
|
|
cwrRfResourceId OBJECT-TYPE
|
|
SYNTAX CwrRFZeroIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the RF resource for which this histogram
|
|
specification applies. If this is 0, the agent will automatically
|
|
use the most logical value for the specified cwrHistClass. If 0 has
|
|
been specified then on reading this object the agent will return the
|
|
RF resource id for which the histogram is being captured."
|
|
::= { cwrHistCtrlEntry 3 }
|
|
|
|
cwrDspNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the DSP on which to create the histogram.
|
|
If 0 is specified then the agent will automatically use the most
|
|
logical DSP for the specified cwrHistClass parameter.
|
|
If 0 has been specified then on reading this object the agent will
|
|
return the DSP number that is being used to capture this histogram."
|
|
::= { cwrHistCtrlEntry 4 }
|
|
|
|
cwrStartBinValue OBJECT-TYPE
|
|
SYNTAX Integer32 (-2147483647..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the maximum of the values that will be
|
|
collected in the first bin of the histogram.
|
|
All values < cwrStartBinValue will be kept in the first
|
|
histogram bin."
|
|
::= { cwrHistCtrlEntry 5 }
|
|
|
|
cwrBinDelta OBJECT-TYPE
|
|
SYNTAX Integer32 (2..2147483647)
|
|
UNITS "Powers of 2"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the range of values of the sampled data that
|
|
should be accounted for in one histogram bin. For example all data
|
|
samples between x..y (where y = x + cwrBinDelta - 1), will be
|
|
counted and placed in the same bin."
|
|
::= { cwrHistCtrlEntry 6 }
|
|
|
|
cwrNumHistBins OBJECT-TYPE
|
|
SYNTAX Integer32 (1..508)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents total number of bins to be created for the
|
|
histogram."
|
|
::= { cwrHistCtrlEntry 7 }
|
|
|
|
cwrUpdateRate OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents rate at which snapshots of the histogram
|
|
will be available."
|
|
::= { cwrHistCtrlEntry 8 }
|
|
|
|
cwrCollDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the duration for which this histogram must
|
|
be accumulated. After successfully accumulating data for this amount
|
|
of time the collection stops and the cwrHistStatus changes
|
|
to statusCaptured."
|
|
::= { cwrHistCtrlEntry 9 }
|
|
|
|
cwrOwnerId OBJECT-TYPE
|
|
SYNTAX OwnerString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies management station that created this
|
|
histogram specification."
|
|
::= { cwrHistCtrlEntry 10 }
|
|
|
|
cwrHistBitShift OBJECT-TYPE
|
|
SYNTAX INTEGER (0..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of bits by which the signal count
|
|
is right shifted before it is stored in the histogram bin.
|
|
This provides a mechanism to uniformly scale the collected histogram
|
|
to account for overflows."
|
|
::= { cwrHistCtrlEntry 11 }
|
|
|
|
cwrHistToneSelection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cwrCirculate(1),
|
|
cwrAverage(2),
|
|
cwrSpecific(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies which tone in a burst should be sampled for
|
|
capturing the data.
|
|
cwrCirculate(1):
|
|
The successive tones will be used for every successive burst.
|
|
cwrAverage(2):
|
|
The value of every tone in a burst will be averaged.
|
|
cwrspecific(3):
|
|
The identified tone is used."
|
|
DEFVAL { cwrAverage }
|
|
::= { cwrHistCtrlEntry 12 }
|
|
|
|
cwrHistToneValue OBJECT-TYPE
|
|
SYNTAX Integer32 (0..216)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If cwrHistToneSelection is cwrSpecificTone then this object
|
|
identifies tone that should be used for sampling."
|
|
::= { cwrHistCtrlEntry 13 }
|
|
|
|
cwrHistAction OBJECT-TYPE
|
|
SYNTAX CwrCollectionAction
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the action to be carried out on this
|
|
histogram specification. If a histogram has been successfully
|
|
captured then it must be cleared before an other capture
|
|
may be initiated."
|
|
::= { cwrHistCtrlEntry 14 }
|
|
|
|
cwrHistStatus OBJECT-TYPE
|
|
SYNTAX CwrCollectionStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the current state of this histogram
|
|
collection.
|
|
Once the histogram collection is complete the status changes
|
|
statusCaptured and the data is available for use.
|
|
None of the parameters of a histogram specification may be
|
|
modified when the specification is in statusInProgress.
|
|
A statusCaptured or statusStopped histogram must be actionClear'ed
|
|
before another histogram specification may be started.
|
|
The histogram may be read accurately between the cwrUpdateRate
|
|
intervals. If the read spans across the update time data from the
|
|
previous and current updates can be mingled."
|
|
::= { cwrHistCtrlEntry 15 }
|
|
|
|
cwrHistRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object may be used to create or delete a histogram control
|
|
specification."
|
|
::= { cwrHistCtrlEntry 16 }
|
|
|
|
cwrHistPeriodicSum OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The histogram data is updated every cwrUpdateRate seconds.
|
|
When this object is set to true(1), the latest histogram data set
|
|
is summed with the previous histogram data set and the
|
|
cwrHistSummaryTable will reflect cumulative values.
|
|
When set to false(2), only the latest data set is made available
|
|
and the cwrHistSummarytable will reflect the latest values."
|
|
::= { cwrHistCtrlEntry 17 }
|
|
|
|
-- The Histogram Summary Table. This table contains summary Data
|
|
-- about the histograms collected as per the specifications in the
|
|
-- cwrHistCtrlTable.
|
|
cwrHistSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrHistSummaryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains histogram Summary collected based on the
|
|
specifications in the cwrHistCtrlTable."
|
|
::= { cwrRadioHistoryGroup 2 }
|
|
|
|
cwrHistSummaryEntry OBJECT-TYPE
|
|
SYNTAX CwrHistSummaryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrHistSummaryTable.
|
|
It is indexed by the ifIndex and cwrHistIndex."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrHistIndex
|
|
}
|
|
::= { cwrHistSummaryTable 1 }
|
|
|
|
CwrHistSummaryEntry ::= SEQUENCE {
|
|
cwrHistUpdateTime Integer32,
|
|
cwrHistMin Integer32,
|
|
cwrHistMax Integer32,
|
|
cwrHistMean Integer32
|
|
}
|
|
|
|
cwrHistUpdateTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the time in seconds since power up when
|
|
this histogram snapshot was retrieved from the hardware."
|
|
::= { cwrHistSummaryEntry 1 }
|
|
|
|
cwrHistMin OBJECT-TYPE
|
|
SYNTAX Integer32 (-2147483648..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the minimum value of the data sample seen
|
|
for this histogram."
|
|
::= { cwrHistSummaryEntry 2 }
|
|
|
|
cwrHistMax OBJECT-TYPE
|
|
SYNTAX Integer32 (-2147483648..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the maximum value of the data sample seen
|
|
for this histogram."
|
|
::= { cwrHistSummaryEntry 3 }
|
|
|
|
cwrHistMean OBJECT-TYPE
|
|
SYNTAX Integer32 (-2147483648..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the arithemetic mean of the data sample
|
|
values for this histogram."
|
|
::= { cwrHistSummaryEntry 4 }
|
|
|
|
-- The Histogram Data Table. This table contains the Data
|
|
-- about the histograms collected as per the specifications in the
|
|
-- cwrHistCtrlTable.
|
|
cwrHistDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrHistDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains histogram values collected based on the
|
|
specifications in the cwrHistCtrlTable."
|
|
::= { cwrRadioHistoryGroup 3 }
|
|
|
|
cwrHistDataEntry OBJECT-TYPE
|
|
SYNTAX CwrHistDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrHistDataTable. It is
|
|
indexed by the ifIndex and cwrHistIndex and cwrHistBinIndex."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrHistIndex,
|
|
cwrHistBinIndex
|
|
}
|
|
::= { cwrHistDataTable 1 }
|
|
|
|
CwrHistDataEntry ::= SEQUENCE {
|
|
cwrHistBinIndex INTEGER,
|
|
cwrValue Integer32
|
|
}
|
|
|
|
cwrHistBinIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..508)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the histogram bin number for the value
|
|
in cwrValue."
|
|
::= { cwrHistDataEntry 1 }
|
|
|
|
cwrValue OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the value in the histogram bin
|
|
cwrHistBinIndex."
|
|
::= { cwrHistDataEntry 2 }
|
|
|
|
-- The Radio Timeline Group. This group is optional.
|
|
|
|
-- This group includes the following tables:
|
|
-- cwrThresholdTable, cwrTlCtrlTable, cwrTlSummaryTable and cwrTlDataTable.
|
|
|
|
-- This group provides facilities to define thresholds and capture raw
|
|
-- radio signal data.
|
|
|
|
|
|
|
|
-- The Threshold table.
|
|
cwrThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides facilities to establish thresholds for the
|
|
radio signals analyzed on the radio interface. A threshold
|
|
identified in this table may be used to trigger a timeline
|
|
capture in the cwrTlTable."
|
|
::= { cwrRadioTimelineGroup 1 }
|
|
|
|
cwrThresholdEntry OBJECT-TYPE
|
|
SYNTAX CwrThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrThresholdTable."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrThreshIndex
|
|
}
|
|
::= { cwrThresholdTable 1 }
|
|
|
|
CwrThresholdEntry ::= SEQUENCE {
|
|
cwrThreshIndex Integer32,
|
|
cwrThreshAttribute CwrRadioSignalAttribute,
|
|
cwrThreshType CwrThreshLimitType,
|
|
cwrThreshAntId CwrRFZeroIndex,
|
|
cwrThreshValue Integer32,
|
|
cwrThreshHysteresisTime TimeInterval,
|
|
cwrThreshLimitTime TimeInterval,
|
|
cwrThreshDspNum INTEGER,
|
|
cwrThreshRowStatus RowStatus
|
|
}
|
|
|
|
cwrThreshIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, along with ifIndex, identifies this entry."
|
|
::= { cwrThresholdEntry 1 }
|
|
|
|
cwrThreshAttribute OBJECT-TYPE
|
|
SYNTAX CwrRadioSignalAttribute
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the attribute of a radio link which needs to be
|
|
thresholded. For each of these attributes, the cwrThreshType
|
|
identifies the type of change to monitor. When that threshold
|
|
is exceeded a Trap with appropriate parameters will be generated."
|
|
::= { cwrThresholdEntry 2 }
|
|
|
|
cwrThreshType OBJECT-TYPE
|
|
SYNTAX CwrThreshLimitType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the kind of change that needs to be
|
|
monitored for the cwrThreshAttribute. An event is
|
|
generated when the following condition is met."
|
|
::= { cwrThresholdEntry 3 }
|
|
|
|
cwrThreshAntId OBJECT-TYPE
|
|
SYNTAX CwrRFZeroIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the RF resource for which this threshold
|
|
should be defined."
|
|
::= { cwrThresholdEntry 4 }
|
|
|
|
cwrThreshValue OBJECT-TYPE
|
|
SYNTAX Integer32 (-2147483647..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the value to be compared against. The
|
|
cwrThreshType determines the way in which it is used.
|
|
It is used as follows:
|
|
if cwrThreshType is ..
|
|
highThresh : Notify if data sample exceeds the cwrThreshValue.
|
|
lowThresh : Notify if data sample recedes below the cwrThreshValue.
|
|
upChange : Notify if data sample increases by more than
|
|
cwrThreshValue.
|
|
downChange : Notify if data sample decreases by more than
|
|
cwrThreshValue.
|
|
upLimit : Notify if data sample crosses cwrThreshValue while
|
|
increasing in value.
|
|
lowLimit : Notify if data sample crosses cwrThreshValue while
|
|
decreasing in value."
|
|
::= { cwrThresholdEntry 5 }
|
|
|
|
cwrThreshHysteresisTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When radio signals oscillate around threshold values, they
|
|
potentially flood the system with notifications. This object
|
|
specifies the amount of time to wait before sending an
|
|
identical notification if the oscillations continue.
|
|
Notifications are not generated due to any
|
|
threshold value which is reached/exceeded/crossed/etc. during this
|
|
wait time"
|
|
::= { cwrThresholdEntry 6 }
|
|
|
|
cwrThreshLimitTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the amount of time for which the radio signal
|
|
should stabilize before a trap is sent to indicate that the radio
|
|
signal has stabilized."
|
|
::= { cwrThresholdEntry 7 }
|
|
|
|
cwrThreshDspNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the DSP used to monitor this threshold."
|
|
::= { cwrThresholdEntry 8 }
|
|
|
|
cwrThreshRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the status of this threshold entry. It
|
|
may be used to create a new threshold specification.
|
|
For every cwrThreshAttrClass one threshold of cwrThreshType on one
|
|
DSP may be created."
|
|
::= { cwrThresholdEntry 9 }
|
|
|
|
-- Radio Timeline.
|
|
-- A radio timeline is raw radio signal data, that is captured based on the
|
|
-- specifications.
|
|
cwrTlCtrlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrTlCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about timelines configured in
|
|
hardware. The number of data values captured for each timeline
|
|
is configured by setting the variable cwrTlNumDataValues.
|
|
The captured data values can be retreived by reading the
|
|
cwrTlDataTable."
|
|
::= { cwrRadioTimelineGroup 2 }
|
|
|
|
cwrTlCtrlEntry OBJECT-TYPE
|
|
SYNTAX CwrTlCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrTlCtrlTable.
|
|
It is indexed by the ifIndex, cwrTlClass, cwrRfResourceId,
|
|
cwrTlDspNum."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrTlIndex
|
|
}
|
|
::= { cwrTlCtrlTable 1 }
|
|
|
|
CwrTlCtrlEntry ::= SEQUENCE {
|
|
cwrTlIndex Integer32,
|
|
cwrTlClass CwrRadioSignalAttribute,
|
|
cwrTlRfResourceId CwrRFZeroIndex,
|
|
cwrTlDspNum INTEGER,
|
|
cwrTlNumDataValues INTEGER,
|
|
cwrTlDecimationFactor Integer32,
|
|
cwrTlPreSumShift Integer32,
|
|
cwrTlToneSelection INTEGER,
|
|
cwrTlToneValue Integer32,
|
|
cwrTlThreshIndex Integer32,
|
|
cwrTlAction CwrCollectionAction,
|
|
cwrTlStatus CwrCollectionStatus,
|
|
cwrTlPostTrigBufMgmt INTEGER,
|
|
cwrTlRowStatus RowStatus
|
|
}
|
|
|
|
cwrTlIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, along with ifIndex, is the index into this table
|
|
and represents one entry in the table. The entry in this table
|
|
for which cwrTlIndex = x is associated with the entry in
|
|
cwrTlSummaryTable and the entry in cwrTlDataTable for
|
|
which the index variable in those tables has the same value, x."
|
|
::= { cwrTlCtrlEntry 1 }
|
|
|
|
cwrTlClass OBJECT-TYPE
|
|
SYNTAX CwrRadioSignalAttribute
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the attribute for which a timline capture
|
|
is requested.
|
|
When a timeline is requested, cwrTlNumDataValues worth of data
|
|
will be captured."
|
|
::= { cwrTlCtrlEntry 2 }
|
|
|
|
cwrTlRfResourceId OBJECT-TYPE
|
|
SYNTAX CwrRFZeroIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the RF resource for which this timeline
|
|
specification applies.
|
|
If this is 0 then the agent will automatically the most logical
|
|
value for the specified cwrHistClass. If 0 has been specified
|
|
then on reading this object the agent will return the
|
|
RF resource id for which the timeline is being captured."
|
|
::= { cwrTlCtrlEntry 3 }
|
|
|
|
cwrTlDspNum OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the DSP on which this timeline needs to be
|
|
captures.
|
|
If 0 is specified then the agent will automatically use the most
|
|
logical DSP for the specified cwrTlClass parameter.
|
|
If 0 has been specified on create then on reading this object the
|
|
agent will return the DSP number that is being used to capture
|
|
this timeline."
|
|
::= { cwrTlCtrlEntry 4 }
|
|
|
|
cwrTlNumDataValues OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
UNITS "number of data values"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of data values to be captured for
|
|
this timeline. The captured data can be viewed by reading the
|
|
cwrTlDataTable."
|
|
::= { cwrTlCtrlEntry 5 }
|
|
|
|
cwrTlDecimationFactor OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of successive data samples to be
|
|
added and returned. This enables larger data sets to be captured
|
|
even with limited cwrTlNumDataValues."
|
|
::= { cwrTlCtrlEntry 6 }
|
|
|
|
cwrTlPreSumShift OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of bits by which the raw data
|
|
data should be right shifted before applying cwrTlDecimationFactor.
|
|
This provides a mechanims of controlling overflow due to summation."
|
|
::= { cwrTlCtrlEntry 7 }
|
|
|
|
cwrTlToneSelection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cwrCirculate(1),
|
|
cwrAverage(2),
|
|
cwrSpecific(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies which tone in a burst should be used to
|
|
sample data for the timeline.
|
|
cwrCirculate(1):
|
|
The successive tone will be used for every successive burst.
|
|
cwrAverage(2):
|
|
The value of every tone in a burst will be averaged.
|
|
cwrspecific(3):
|
|
The identified tone is used.
|
|
DEFVAL { cwrAverage }"
|
|
::= { cwrTlCtrlEntry 8 }
|
|
|
|
cwrTlToneValue OBJECT-TYPE
|
|
SYNTAX Integer32 (0..216)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If cwrTlToneSelection is cwrSpecificTone then this object
|
|
identifies the tone that should be used for sampling."
|
|
::= { cwrTlCtrlEntry 9 }
|
|
|
|
cwrTlThreshIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the index of the threshold that when
|
|
triggered will start the data capture for this timeline.
|
|
|
|
For a timeline data capture to be triggered by a threshold,
|
|
the threshold must be defined on the same DSP as the timeline.
|
|
|
|
If cwrTlThreshIndex is 0 then there is no threshold associated
|
|
with this timeline and the data samples are captured and returned
|
|
immediately. If cwrTlThresIndex is not 0, then the data samples
|
|
are captured when the threshold fires."
|
|
::= { cwrTlCtrlEntry 10 }
|
|
|
|
cwrTlAction OBJECT-TYPE
|
|
SYNTAX CwrCollectionAction
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the action to be carried out on this
|
|
timeline specification. If a timeline has been successfully
|
|
captured then it must be cleared before an other capture
|
|
may be initiated."
|
|
::= { cwrTlCtrlEntry 11 }
|
|
|
|
cwrTlStatus OBJECT-TYPE
|
|
SYNTAX CwrCollectionStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the current state of this timeline
|
|
collection.
|
|
Once the timeline collection is complete the status changes
|
|
statusCaptured and the data is available for use.
|
|
None of the parameters of a timeline specification may be modified
|
|
when the specification is in statusInProgress.
|
|
A statusCaptured or statusStopped histogram must be actionClear'ed
|
|
before another timeline specification may be started."
|
|
::= { cwrTlCtrlEntry 12 }
|
|
|
|
cwrTlPostTrigBufMgmt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
preTrigger(1),
|
|
postTrigger(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Once a trigger fires, this object determines which portion of the
|
|
collected data to capture for use. If it is:
|
|
preTrigger(1) : Then most of the data collected prior to trigger
|
|
is captured.
|
|
postTrigger(2): Then most of the data collected after the trigger
|
|
is captured."
|
|
::= { cwrTlCtrlEntry 13 }
|
|
|
|
cwrTlRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object may be used to create or delete a timeline control
|
|
specification.
|
|
|
|
Once created data sampling starts based on the value of
|
|
cwrTlAction. The data capture depends on the value of
|
|
cwrTlThreshIndex.
|
|
The actual data is collected based on the cwrTlThreshIndex,
|
|
if cwrTlThreshIndex is 0 then there is no stop trigger associated
|
|
with this timeline and the data samples are captured and returned
|
|
immediately. If cwrTlThresIndex is not 0, then the data samples
|
|
are captured when the threshold fires."
|
|
::= { cwrTlCtrlEntry 14 }
|
|
|
|
-- The Timeline Summary Table. This table contains summary Data
|
|
-- about the timeline collected as per the specifications in the
|
|
-- cwrTlCtrlTable.
|
|
cwrTlSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrTlSummaryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains Timeline Summary collected based on the
|
|
specifications in the cwrTlCtrlTable."
|
|
::= { cwrRadioTimelineGroup 3 }
|
|
|
|
cwrTlSummaryEntry OBJECT-TYPE
|
|
SYNTAX CwrTlSummaryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrTlSummaryTable.
|
|
It is indexed by the ifIndex and cwrTlIndex."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrTlIndex
|
|
}
|
|
::= { cwrTlSummaryTable 1 }
|
|
|
|
CwrTlSummaryEntry ::= SEQUENCE {
|
|
cwrTlUpdateTime Integer32,
|
|
cwrTlNumValues Integer32,
|
|
cwrTlTriggerLoc Integer32
|
|
}
|
|
|
|
cwrTlUpdateTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the time in seconds since power up when
|
|
this timeline capture was completed."
|
|
::= { cwrTlSummaryEntry 1 }
|
|
|
|
cwrTlNumValues OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of values available in the
|
|
timeline."
|
|
::= { cwrTlSummaryEntry 2 }
|
|
|
|
cwrTlTriggerLoc OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of cwrTlValueIndex which represents
|
|
the entry in the cwrTlDataTable that caused the stop trigger to
|
|
fire, thereby resulting in this timeline to be collected."
|
|
::= { cwrTlSummaryEntry 3 }
|
|
|
|
-- The Timeline Data Table. This table contains the Data
|
|
-- about the timelines collected as per the specifications in the
|
|
-- cwrTlCtrlTable.
|
|
cwrTlDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrTlDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains data values collected for the timelines
|
|
specified in the cwrTlCtrlTable. The number of data values
|
|
displayed for each timeline is determined by the value specified
|
|
for cwrTlNumDataValues in cwrTlCtrlTable."
|
|
::= { cwrRadioTimelineGroup 4 }
|
|
|
|
cwrTlDataEntry OBJECT-TYPE
|
|
SYNTAX CwrTlDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrTlDataTable. It is indexed by
|
|
ifIndex, cwrTlIndex, and cwrTlValueIndex."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrTlIndex,
|
|
cwrTlValueIndex
|
|
}
|
|
::= { cwrTlDataTable 1 }
|
|
|
|
CwrTlDataEntry ::= SEQUENCE {
|
|
cwrTlValueIndex INTEGER,
|
|
cwrTlValue Integer32
|
|
}
|
|
|
|
cwrTlValueIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, along with ifIndex and cwrTlIndex, is the index
|
|
into the timeline data table."
|
|
::= { cwrTlDataEntry 1 }
|
|
|
|
cwrTlValue OBJECT-TYPE
|
|
SYNTAX Integer32 (-2147483648..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the radio signal data sampled."
|
|
::= { cwrTlDataEntry 2 }
|
|
|
|
-- Snapshot Group: This group is optional.
|
|
|
|
-- This group provides facilities to capture raw radio signal attributes.
|
|
-- The key difference between this group and the Timeline Group is that
|
|
-- this group provides facilities to capture up to 4 synchronized
|
|
-- signal attributes simultaneously. The capture initiated by a single
|
|
-- user controlled trigger.
|
|
|
|
-- In this group many of the attributes are represented by complex numbers
|
|
-- Each such attribute is indicated as value(I, q).
|
|
cwrSnapshotCtrlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrSnapshotCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about the snapshots configured in
|
|
hardware. When data is collected it will be stored in
|
|
cwrSnapDataTable."
|
|
::= { cwrRadioSnapshotGroup 1 }
|
|
|
|
cwrSnapshotCtrlEntry OBJECT-TYPE
|
|
SYNTAX CwrSnapshotCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrSnapshotCtrlTable
|
|
It is indexed by the ifIndex and cwrSnapshotDspNum."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrSnapshotDspNum
|
|
}
|
|
::= { cwrSnapshotCtrlTable 1 }
|
|
|
|
CwrSnapshotCtrlEntry ::= SEQUENCE {
|
|
cwrSnapshotDspNum INTEGER,
|
|
cwrSnapshotType Integer32,
|
|
cwrSnapshotAction CwrCollectionAction,
|
|
cwrSnapshotStatus CwrCollectionStatus,
|
|
cwrSnapshotRowStatus RowStatus
|
|
}
|
|
|
|
cwrSnapshotDspNum OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the DSP at which the snapshot needs to
|
|
be collected."
|
|
::= { cwrSnapshotCtrlEntry 1 }
|
|
|
|
cwrSnapshotType OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the attribute that is being snapshoted by
|
|
the hardware. When a snapshot request is issued up to 4 simultaneous
|
|
radio signal attribute may be captured at once.
|
|
The 4 attributes are specified by bit OR'ing the snapshot types
|
|
identified below. When a snapshot specification
|
|
is started all the specified attributes are captured simultaneously.
|
|
|
|
The TX and RX types cannot be mixed. RX, Sync types can be mixed.
|
|
|
|
When a snapshot request is issued up to four radio signal attributes
|
|
may be requested at once, one from each set:
|
|
===============================================
|
|
Type Set1 Set2
|
|
===============================================
|
|
RX y1n(x1) y2n(x2)
|
|
H2k(x80) H1k(x40)
|
|
- -
|
|
Sync - FreqCorr(x8000)
|
|
- FLL_FFT_Sp(x20000)
|
|
TX CodecIn(x200) IFFTIn(x400)
|
|
===============================================
|
|
|
|
===============================================
|
|
Type Set3 Set4
|
|
===============================================
|
|
RX Y2k(x8) Y1k(x4)
|
|
h1n(x10) h2n(x20)
|
|
zhat(x100) -
|
|
Sync FreqOffCF(x2000)(*) BrstTimeCF(x1000)(*)
|
|
- TT_FCorr(x10000)
|
|
TX - RoundOut(x800)
|
|
===============================================
|
|
|
|
(*) BrstTimeCF cannot be mixed with Set2
|
|
(*) FreqOffCF cannot be mixed with Set1
|
|
|
|
Note that only the Tx* attributes may be captured on DSP's 1, 2.
|
|
|
|
The attributes are:
|
|
RxRawBurstAnt1Y1n(0x01):
|
|
This represents a snapshot of the received signal for RF
|
|
resource 1. For every sample the real and imaginary components
|
|
are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
RxRawBurstAnt2Y2n(0x02):
|
|
This represents a snapshot of the received signal for RF
|
|
resource 2. For every sample the real and imaginary components
|
|
are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
RxSpectrumAnt1Y1k(0x04):
|
|
This represents a snapshot of the spectrum of the received
|
|
signal for RF resource 1. For every sample the real and
|
|
imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
RxSpectrumAnt2Y2k(0x08):
|
|
This represents a snapshot of the spectrum of the received
|
|
signal for RF resource 2. For every sample the real and
|
|
imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
RxTimeDomainChannelAnt1H1n(0x10):
|
|
This represents a snapshot of the time domain channel
|
|
for RF resource 1. For every sample the real and
|
|
imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
RxTimeDomainChannelAnt2H2n(0x20):
|
|
This represents a snapshot of the time domain channel
|
|
for RF resource 2. For every sample the real and
|
|
imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
RxFreqDomainChannelAnt1H1k(0x40):
|
|
This represents a snapshot of the frequency domain channel
|
|
for RF resource 1. For every sample the real and
|
|
imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
RxFreqDomainChannelAnt2H2k(0x80),
|
|
This represents a snapshot of the frequency domain channel
|
|
for RF resource 2. For every sample the real and
|
|
imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
RxConstellationZHatk(0x100):
|
|
This represents a snapshot of the soft decisions.
|
|
For every sample the real and imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
TxCodecInput(0x200):
|
|
This represents a snapshot of input values to the Tx Code.
|
|
Units: Real values.
|
|
Value: 32 bit quantities.
|
|
|
|
TxIFFTInput(0x400):
|
|
This represents a snapshot of the IFFT signal for the
|
|
Transmitted data.
|
|
For every sample the real and imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
TxRoundOutput(0x800):
|
|
This represents a snapshot of the Rounded Constellation signal
|
|
for the Transmitted data.
|
|
For every sample the real and imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
SyncBurstTimeCostFunc(0x1000):
|
|
This represents the timing cost function for Sync bursts.
|
|
Units: Real values.
|
|
Value: 32 bit quantities.
|
|
|
|
SynFreqOffsetCostFunc(0x2000):
|
|
This represents a snapshot of the frequeny offsets.
|
|
For every sample the real and imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
SyncFllFreqCorrelation(0x8000):
|
|
This represents a snapshot of Frequency correlation.
|
|
For every sample the real and imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
SyncFllTrainToneCorrelation(0x10000):
|
|
This represents a snapshot of Frequency locked loop's Training
|
|
tone correlation.
|
|
For every sample the real and imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities.
|
|
|
|
SyncFllFFTSpectrum(0x20000):
|
|
This represents a snapshot of Frequency locked loop, FFT
|
|
Spectrum.
|
|
For every sample the real and imaginary components are captured.
|
|
Units: (I, q)
|
|
Value: 32 bit quantities."
|
|
::= { cwrSnapshotCtrlEntry 2 }
|
|
|
|
cwrSnapshotAction OBJECT-TYPE
|
|
SYNTAX CwrCollectionAction
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the action to be carried out on this
|
|
snapshot specification. If a snapshot has been successfully
|
|
captured then it must be cleared before an other capture
|
|
may be initiated."
|
|
::= { cwrSnapshotCtrlEntry 3 }
|
|
|
|
cwrSnapshotStatus OBJECT-TYPE
|
|
SYNTAX CwrCollectionStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the current status of this snapshot
|
|
specification. When the status in statusInProgress none of the
|
|
snapshot parameters can be configured. When the status is
|
|
statusCaptured then data is available for use."
|
|
::= { cwrSnapshotCtrlEntry 4 }
|
|
|
|
cwrSnapshotRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object may be used to create or delete this snapshot
|
|
specification."
|
|
::= { cwrSnapshotCtrlEntry 5 }
|
|
|
|
-- The Snapshot Summary Table. This table contains summary information
|
|
-- for the data captured by a snapshot specification
|
|
-- about the snapshots collected as per the specifications in the
|
|
-- cwrSnapshotCtrlTable.
|
|
cwrSnapSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrSnapSummaryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains summary information for captured snapshots
|
|
defined in cwrSnapshotCtrlTable."
|
|
::= { cwrRadioSnapshotGroup 2 }
|
|
|
|
cwrSnapSummaryEntry OBJECT-TYPE
|
|
SYNTAX CwrSnapSummaryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrSnapSummaryTable. It is indexed
|
|
by the ifIndex and cwrSnapDspNum."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrSnapshotDspNum
|
|
}
|
|
::= { cwrSnapSummaryTable 1 }
|
|
|
|
CwrSnapSummaryEntry ::= SEQUENCE {
|
|
cwrSnapAttr1Id Integer32,
|
|
cwrSnapAttr1Size Integer32,
|
|
cwrSnapAttr2Id Integer32,
|
|
cwrSnapAttr2Size Integer32,
|
|
cwrSnapAttr3Id Integer32,
|
|
cwrSnapAttr3Size Integer32,
|
|
cwrSnapAttr4Id Integer32,
|
|
cwrSnapAttr4Size Integer32
|
|
}
|
|
|
|
cwrSnapAttr1Id OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the first snapshot attribute value."
|
|
::= { cwrSnapSummaryEntry 2 }
|
|
|
|
cwrSnapAttr1Size OBJECT-TYPE
|
|
SYNTAX Integer32 (0..4096)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of values captured for the
|
|
snapshot cwrSnapAttr1Id."
|
|
::= { cwrSnapSummaryEntry 3 }
|
|
|
|
cwrSnapAttr2Id OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the second snapshot attribute value."
|
|
::= { cwrSnapSummaryEntry 4 }
|
|
|
|
cwrSnapAttr2Size OBJECT-TYPE
|
|
SYNTAX Integer32 (0..4096)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of values captured for the
|
|
snapshot cwrSnapAttr2Id."
|
|
::= { cwrSnapSummaryEntry 5 }
|
|
|
|
cwrSnapAttr3Id OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the third snapshot attribute value."
|
|
::= { cwrSnapSummaryEntry 6 }
|
|
|
|
cwrSnapAttr3Size OBJECT-TYPE
|
|
SYNTAX Integer32 (0..4096)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of values captured for the
|
|
snapshot cwrSnapAttr3Id."
|
|
::= { cwrSnapSummaryEntry 7 }
|
|
|
|
cwrSnapAttr4Id OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the third snapshot attribute value."
|
|
::= { cwrSnapSummaryEntry 8 }
|
|
|
|
cwrSnapAttr4Size OBJECT-TYPE
|
|
SYNTAX Integer32 (0..4096)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the number of values captured for the
|
|
snapshot cwrSnapAttr4Id."
|
|
::= { cwrSnapSummaryEntry 9 }
|
|
|
|
-- The Snapshot Data Table. This table contains the Data
|
|
-- about the snapshots collected as per the specifications in the
|
|
-- cwrSnapshotCtrlTable.
|
|
cwrSnapDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrSnapDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains snapshot values collected based on the
|
|
specifications in the cwrSnapshotCtrlTable."
|
|
::= { cwrRadioSnapshotGroup 3 }
|
|
|
|
cwrSnapDataEntry OBJECT-TYPE
|
|
SYNTAX CwrSnapDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrSnapDataTable. It is indexed
|
|
by the ifIndex and cwrSnapValueIndex.
|
|
|
|
The values in this table represent real numbers or complex numbers.
|
|
If they are real numbers then cwrRealPart contains the data and
|
|
cwrImaginaryPart is zero."
|
|
INDEX {
|
|
ifIndex,
|
|
cwrSnapshotDspNum,
|
|
cwrSnapValueIndex
|
|
}
|
|
::= { cwrSnapDataTable 1 }
|
|
|
|
CwrSnapDataEntry ::= SEQUENCE {
|
|
cwrSnapValueIndex INTEGER,
|
|
cwrRealPart Integer32,
|
|
cwrImaginaryPart Integer32
|
|
}
|
|
|
|
cwrSnapValueIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4096)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the snapshot entry index number."
|
|
::= { cwrSnapDataEntry 1 }
|
|
|
|
cwrRealPart OBJECT-TYPE
|
|
SYNTAX Integer32 (-2147483648..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The data sample value. Real part."
|
|
::= { cwrSnapDataEntry 2 }
|
|
|
|
cwrImaginaryPart OBJECT-TYPE
|
|
SYNTAX Integer32 (-2147483648..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The data sample value. Imaginary part if the attribute is
|
|
represented by a complex number."
|
|
::= { cwrSnapDataEntry 3 }
|
|
|
|
-- The Antenna Group - This group is optional.
|
|
|
|
|
|
|
|
-- The Antenna Table. This table contains information about the
|
|
-- antennas available in the router.
|
|
cwrAntennaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrAntennaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about the antenns available for
|
|
use."
|
|
::= { cwrRadioAntennaGroup 1 }
|
|
|
|
cwrAntennaEntry OBJECT-TYPE
|
|
SYNTAX CwrAntennaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents one entry in the cwrAntennaTable. This table
|
|
provides details on the antennas available for use on the local
|
|
system. It is indexed by cwrAntennaIndex."
|
|
INDEX { cwrAntennaIndex }
|
|
::= { cwrAntennaTable 1 }
|
|
|
|
CwrAntennaEntry ::= SEQUENCE {
|
|
cwrAntennaIndex Integer32,
|
|
cwrAntennaXDim Integer32,
|
|
cwrAntennaYDim Integer32,
|
|
cwrAntennaType DisplayString,
|
|
cwrAntennaDescr DisplayString,
|
|
cwrAntennaGain Integer32,
|
|
cwrAntennaPolarization INTEGER
|
|
}
|
|
|
|
cwrAntennaIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the index of this entry in the
|
|
cwrAntennaTable."
|
|
::= { cwrAntennaEntry 1 }
|
|
|
|
cwrAntennaXDim OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
UNITS "Inches"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the dimension of the antenna in the
|
|
X direction."
|
|
::= { cwrAntennaEntry 2 }
|
|
|
|
cwrAntennaYDim OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
UNITS "Inches"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the dimension of the antenna in the
|
|
Y direction."
|
|
::= { cwrAntennaEntry 3 }
|
|
|
|
cwrAntennaType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents antenna type for example 'dish-antenna'."
|
|
::= { cwrAntennaEntry 4 }
|
|
|
|
cwrAntennaDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object describes the antenna."
|
|
::= { cwrAntennaEntry 5 }
|
|
|
|
cwrAntennaGain OBJECT-TYPE
|
|
SYNTAX Integer32 (0..60)
|
|
UNITS "dBi : decibel Isotropic"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object represents the gain of this antenna."
|
|
::= { cwrAntennaEntry 6 }
|
|
|
|
cwrAntennaPolarization OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vertical(1),
|
|
horizontal(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the electrirc polarization of the antanna."
|
|
::= { cwrAntennaEntry 7 }
|
|
|
|
-- The Test table.
|
|
-- This table provides facilities to test the wireless hardware.
|
|
cwrTestGroup OBJECT IDENTIFIER
|
|
::= { cwrRadioInternal 1 }
|
|
|
|
cwrLoopbackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrLoopbackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides facilities to establish loopback points in the
|
|
radio hardware to exercise various sections of the hardware."
|
|
::= { cwrTestGroup 1 }
|
|
|
|
cwrLoopbackEntry OBJECT-TYPE
|
|
SYNTAX CwrLoopbackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There exists one such entry for every interface in the ifTable
|
|
which has an ifType of propWirelessP2P(157)."
|
|
INDEX { ifIndex }
|
|
::= { cwrLoopbackTable 1 }
|
|
|
|
CwrLoopbackEntry ::= SEQUENCE {
|
|
cwrLocalLoopbackPoint INTEGER
|
|
}
|
|
|
|
cwrLocalLoopbackPoint OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
codec(1),
|
|
framer(2),
|
|
fir(3),
|
|
if(4),
|
|
rf(5),
|
|
rfDiversity(6),
|
|
ifMain(7),
|
|
ifDiversity(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the point in the system where the data
|
|
signal is looped back.
|
|
|
|
none(0) - no loopback
|
|
codec(1) - loopback at the Encoder/Decoder module.
|
|
This exercises the framer, and codec modules
|
|
framer(2) - loopback at the 'framer' module.
|
|
fir(3) - loopback at the 'Finite Impulse Response' module.
|
|
This exercises the framer, codec, and FIR modules.
|
|
if(4) - loopback at the 'Internal Frequency' module using
|
|
both the main and the diversity receive paths.
|
|
This exercises the framer, codec, FIR, and
|
|
IF modules.
|
|
rf(5) - loopback at the main RF unit via the main receive
|
|
path in the IF module. This exercises the framer,
|
|
codec, FIR, IF, and RF modules.
|
|
rfDiversity(6) - loopback at the main RF unit but route it through
|
|
the diversity receive path in the IF module. This
|
|
exercises the framer, codec, FIR, IF, and RF
|
|
modules.
|
|
ifMain(7) - loopack at the IF module using only the Main
|
|
receive path. This exercises the framer, codec,
|
|
FIR, and IF modules.
|
|
ifDiversity(8) - loopack at the IF module using only the diversity
|
|
receive path. This exercises the framer, codec,
|
|
FIR, and IF modules."
|
|
::= { cwrLoopbackEntry 1 }
|
|
|
|
cwrScopePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrScopePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides facilities to redirect a portion of the signal
|
|
being processed by a DSP to a scope port on the radio. An
|
|
oscilloscope may be connected to the scope port to analyze the
|
|
signal."
|
|
::= { cwrTestGroup 2 }
|
|
|
|
cwrScopePortEntry OBJECT-TYPE
|
|
SYNTAX CwrScopePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There exists one such entry for every interface in the ifTable
|
|
which has an ifType of propWirelessP2P(157)."
|
|
INDEX { ifIndex }
|
|
::= { cwrScopePortTable 1 }
|
|
|
|
CwrScopePortEntry ::= SEQUENCE {
|
|
cwrScopePortOn TruthValue,
|
|
cwrScopePortDsp INTEGER,
|
|
cwrScopePortAttribute Integer32
|
|
}
|
|
|
|
cwrScopePortOn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to true(1), then the DSP identified by cwrScopePortDsp, will
|
|
redirect a portion of the output signal for the attribute identified
|
|
by cwrScopeAttribute to the scope port."
|
|
::= { cwrScopePortEntry 1 }
|
|
|
|
cwrScopePortDsp OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies the DSP that should redirect a portion of the
|
|
signal data to the scope port."
|
|
::= { cwrScopePortEntry 2 }
|
|
|
|
cwrScopePortAttribute OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the attribute to be redirected to the scope port.
|
|
The attributes that may be redirected to scope port is the same
|
|
as that identified in cwrSnapshotType."
|
|
::= { cwrScopePortEntry 3 }
|
|
|
|
-- Trap Group
|
|
cwrRadioTrapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CwrRadioTrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides information about the last trap that was
|
|
generated on this interface."
|
|
::= { cwrRadioLatestTrap 1 }
|
|
|
|
cwrRadioTrapEntry OBJECT-TYPE
|
|
SYNTAX CwrRadioTrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents one entry in this table."
|
|
INDEX { ifIndex }
|
|
::= { cwrRadioTrapTable 1 }
|
|
|
|
CwrRadioTrapEntry ::= SEQUENCE {
|
|
cwrTrapReason DisplayString
|
|
}
|
|
|
|
cwrTrapReason OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The explanation string for the event trap cwrEventId."
|
|
::= { cwrRadioTrapEntry 1 }
|
|
|
|
-- The following traps are generated by the radio system. These traps are not
|
|
-- in response to any threshold specification that might have been defined.
|
|
cwrTrapConfigMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrTrapReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The radio subsystem has detected that the combination of the
|
|
configuration parameters that has been requested is inconsistent
|
|
and cannot be supported.
|
|
The cwrTrapReason is the textual description of what parameter
|
|
causes the mismatch."
|
|
::= { cwrRadioDevTraps 1 }
|
|
|
|
cwrTrapInitFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrTrapReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The radio subsystem has failed to initialize the hardware
|
|
successfully.
|
|
This implies that there is a critical error condition in the
|
|
associated hardware. The cwrTrapReason specifies the reason
|
|
the init failed."
|
|
::= { cwrRadioDevTraps 2 }
|
|
|
|
cwrTrapLinkQuality NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrTrapReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The radio subsystem has detected a significant change in
|
|
the radio link quality. The cwrTrapReason will describe
|
|
the quality."
|
|
::= { cwrRadioDevTraps 3 }
|
|
|
|
cwrTrapLinkSyncLost NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The radio link has lost synchronization with the remote end."
|
|
::= { cwrRadioDevTraps 4 }
|
|
|
|
cwrTrapLinkSyncAcquired NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The radio link has acquired synchronization with the remote end."
|
|
::= { cwrRadioDevTraps 5 }
|
|
|
|
cwrTrapIfRxOsc NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrIfRxOscState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IF receive frequency oscillator has changed state."
|
|
::= { cwrRadioDevTraps 6 }
|
|
|
|
cwrTrapIfTxOsc NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrIfTxOscState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IF transmit frequency oscillator has changed state."
|
|
::= { cwrRadioDevTraps 7 }
|
|
|
|
cwrTrapIfRefOsc NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrIfRefOscState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IF Reference Frequency oscillator has changed state."
|
|
::= { cwrRadioDevTraps 8 }
|
|
|
|
cwrTrapRfSupplyVoltage NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrRfSupplyVoltageState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The supply voltage to the RF resource has changed.
|
|
The cwrRfSupplyVoltageState specifies whether the supply voltage is
|
|
in spec or not."
|
|
::= { cwrRadioDevTraps 9 }
|
|
|
|
cwrTrapRfRxOsc NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrRfRxOscState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RF receive frequency oscillator has changed state.
|
|
The cwrRfIndex identifies the RF resource that is the cause
|
|
of this trap. The cwrRfRxOscState specifies the
|
|
state of the oscilator."
|
|
::= { cwrRadioDevTraps 10 }
|
|
|
|
cwrTrapRfTxOsc NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrRfTxOscState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RF transmit frequency oscillator has changed state.
|
|
The cwrRfIndex identifies the RF resource that is the cause
|
|
of this trap. The cwrRfRxOscState specifies the
|
|
state of the oscilator."
|
|
::= { cwrRadioDevTraps 11 }
|
|
|
|
cwrTrapRfTemp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrRfTemperature
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature of the RF module identified by cwrRfIndex
|
|
has exceeded a defined reference."
|
|
::= { cwrRadioDevTraps 12 }
|
|
|
|
cwrTrapRfStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrRfStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates that the RF resource either
|
|
came online(1) or went offline(2).
|
|
The cwrRfIndex will identify which resource changed state
|
|
and cwrRfStatus will identify what state it is in."
|
|
::= { cwrRadioDevTraps 13 }
|
|
|
|
cwrTrapLink1HrThresh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrTrapReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One of cwrLink1HrESAlarmThresh, cwrLink1HrSESAlarmThresh,
|
|
cwrLink1HrCSESAlarmThresh, cwrLink1HrDCMAlarmThresh was
|
|
was exceeded. The cwrTrapReason will identify which
|
|
threshold was exceeded."
|
|
::= { cwrRadioDevTraps 14 }
|
|
|
|
cwrTrapLink24HrThresh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
cwrTrapReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One of cwrLink24HrESAlarmThresh, cwrLink24HrSESAlarmThresh,
|
|
cwrLink24HrCSESAlarmThresh, cwrLink24HrDCMAlarmThresh was
|
|
was exceeded. The cwrTrapReason will identify which
|
|
threshold was exceeded."
|
|
::= { cwrRadioDevTraps 15 }
|
|
|
|
-- The following trap is generated in response to a threshold defined
|
|
-- in cwrThreshTable.
|
|
cwrTrapThresh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cwrThreshValue,
|
|
cwrThreshHysteresisTime,
|
|
cwrThreshLimitTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The radio subsystem generates this trap when a threshold crosses
|
|
its specified limit. The parameters identify the following
|
|
cwrThreshValue - The value that was crossed.
|
|
cwrThreshHysteresisTime - The Hysteresis time that was specified.
|
|
cwrThreshLimitTime - The Limit time that was specified."
|
|
::= { cwrRadioThreshTraps 1 }
|
|
|
|
-- ============================================================================
|
|
|
|
-- Compliance Statements
|
|
cwrRadioIfConformance OBJECT IDENTIFIER
|
|
::= { ciscoWirelessIfMIB 3 }
|
|
|
|
cwrRadioIfCompliances OBJECT IDENTIFIER
|
|
::= { cwrRadioIfConformance 1 }
|
|
|
|
cwrRadioIfGroups OBJECT IDENTIFIER
|
|
::= { cwrRadioIfConformance 2 }
|
|
|
|
cwrRadioBasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for devices that Point to Point
|
|
wireless interface compliant to Cisco Systems Inc.
|
|
specification."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cwrComplianceRadioGroup,
|
|
cwrComplianceRadioPhyQualityGroup,
|
|
cwrComplianceRadioRfGroup,
|
|
cwrComplianceReqLinkMetrics,
|
|
cwrComplianceRadioTestGroup
|
|
}
|
|
|
|
GROUP cwrComplianceHistoryGroup
|
|
DESCRIPTION
|
|
"The History group may be implemented on both the Radio Master and
|
|
Radio Slave. It is optional."
|
|
|
|
GROUP cwrComplianceRadioTlGroup
|
|
DESCRIPTION
|
|
"The Timeline group may be implemented on both the Radio Master and
|
|
Radio Slave. It is optional."
|
|
|
|
GROUP cwrComplianceRadioSnapshotGroup
|
|
DESCRIPTION
|
|
"The Snapshot group may be implemented on both the Radio Master and
|
|
Radio Slave. It is optional."
|
|
|
|
GROUP cwrComplianceRadioAntennaGroup
|
|
DESCRIPTION
|
|
"This group may be implemented on both the Radio Master and Radio
|
|
Slave. It is optional."
|
|
|
|
GROUP cwrComplianceRadioPhyByteErrGroup
|
|
DESCRIPTION
|
|
"This group may be implemented on both the Radio Master and Radio
|
|
Slave. It is optional."
|
|
|
|
GROUP cwrComplianceNotifGroup
|
|
DESCRIPTION
|
|
"This group of notifications is optional."
|
|
|
|
::= { cwrRadioIfCompliances 1 }
|
|
|
|
-- The Basic Radio Group.
|
|
cwrComplianceRadioGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrRadioNextIndex,
|
|
cwrAcquisitionMode,
|
|
cwrSelfTest,
|
|
cwrBasePrivacySupport,
|
|
cwrTxRfIndex,
|
|
cwrRx1RfIndex,
|
|
cwrRx2RfIndex,
|
|
cwrClockRefExt,
|
|
cwrAntAlignment,
|
|
cwrNumRxAntenna,
|
|
cwrBandwidth,
|
|
cwrThroughput,
|
|
cwrOperatingBand,
|
|
cwrTxFrequency,
|
|
cwrRxFrequency,
|
|
cwrTxPower,
|
|
cwrCableLoss,
|
|
cwrOpStatus,
|
|
cwrCableLossDiversity,
|
|
cwrBurstSize
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented to configure a point to point wireless
|
|
radio. This includes the cwrBurstSize object."
|
|
::= { cwrRadioIfGroups 1 }
|
|
|
|
cwrComplianceRadioPhyQualityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrArqPctBw,
|
|
cwrArqVoiceLatency,
|
|
cwrArqDataLatency,
|
|
cwrArqBurstSize,
|
|
cwrArqTypicalBitRate,
|
|
cwrArqMinBitRate,
|
|
cwrArqMaxLatencyJitter,
|
|
cwrArqReset,
|
|
cwrArqOn,
|
|
cwrTrapReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented to tune phy quality in the point to
|
|
point wireless systems."
|
|
::= { cwrRadioIfGroups 2 }
|
|
|
|
cwrComplianceRadioRfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrRfResIndex,
|
|
cwrRFOpMode,
|
|
cwrTxFreqRangeMin,
|
|
cwrTxFreqRangeMax,
|
|
cwrRxFreqRangeMin,
|
|
cwrRxFreqRangeMax,
|
|
cwrMinTxPower,
|
|
cwrMaxTxPower,
|
|
cwrRfTxOscState,
|
|
cwrRfAntIndex,
|
|
cwrRfRxOscState,
|
|
cwrRfTemperature,
|
|
cwrRfSupplyVoltageState,
|
|
cwrRfStatus,
|
|
cwrRfControlChannelStatus,
|
|
cwrBurstSizeGroup,
|
|
cwrIfTxOscState,
|
|
cwrIfRxOscState,
|
|
cwrIfRefOscState,
|
|
cwrIfResIndex,
|
|
cwrIfInpFreq,
|
|
cwrIfOutFreq
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented to tune phy quality in the point to
|
|
point wireless systems. This group includes cwrBurstSizeGroup."
|
|
::= { cwrRadioIfGroups 3 }
|
|
|
|
-- Required Link Metrics Group.
|
|
cwrComplianceReqLinkMetrics OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrLinkCwESThresh,
|
|
cwrLinkLowCwDSThresh,
|
|
cwrLinkHighCwDSThresh,
|
|
cwrLinkCSESThresh,
|
|
cwrLink1HrESAlarmThresh,
|
|
cwrLink1HrSESAlarmThresh,
|
|
cwrLink1HrCSESAlarmThresh,
|
|
cwrLink1HrDCMAlarmThresh,
|
|
cwrLink24HrESAlarmThresh,
|
|
cwrLink24HrSESAlarmThresh,
|
|
cwrLink24HrCSESAlarmThresh,
|
|
cwrLink24HrDCMAlarmThresh,
|
|
cwrAvailableSeconds,
|
|
cwrUnAvailableSeconds,
|
|
cwrSyncLossSeconds,
|
|
cwrPctErrorFreeSeconds,
|
|
cwrPctErroredSeconds,
|
|
cwrPctSeverelyErroredSeconds,
|
|
cwrPctAvailSeconds,
|
|
cwrPctCwDegradedMinutes,
|
|
cwrSyncSuccessCount,
|
|
cwrSyncFailureCount,
|
|
cwrManagedSyncLoss,
|
|
cwrAutomaticSyncLoss,
|
|
cwrLastSyncSuccessTime,
|
|
cwrLastSyncFailTime,
|
|
cwrEffectivePhyDataRate,
|
|
cwrPctEffectivePhyDataRate,
|
|
cwr24HrUpdateTime,
|
|
cwr24HrErrorFreeSeconds,
|
|
cwr24HrErroredSeconds,
|
|
cwr24HrSevErroredSeconds,
|
|
cwr24HrConsecSvErrSeconds,
|
|
cwr24HrDegradedMinutes,
|
|
cwr24HrTotalErroredCodewords,
|
|
cwr24HrTotalCodewords,
|
|
cwr1HrUpdateTime,
|
|
cwr1HrErrorFreeSeconds,
|
|
cwr1HrErroredSeconds,
|
|
cwr1HrSevErroredSeconds,
|
|
cwr1HrConsecSvErrSeconds,
|
|
cwr1HrDegradedMinutes,
|
|
cwr1HrErroredCodewords,
|
|
cwr1HrTotalCodewords,
|
|
cwr1MinUpdateTime,
|
|
cwr1MinErrorFreeSeconds,
|
|
cwr1MinErroredSeconds,
|
|
cwr1MinSevErroredSeconds,
|
|
cwr1MinConsecSvCwErrSeconds,
|
|
cwr1MinDegradedSeconds,
|
|
cwr1MinErroredCodewords,
|
|
cwr1MinCodewords,
|
|
cwr1SecUpdateTime,
|
|
cwr1SecRxCodewords,
|
|
cwr1SecRSCodewordErrors,
|
|
cwr1SecArqCodewordErrors,
|
|
cwr1SecRxRrCount,
|
|
cwr1SecRxRrEventCount,
|
|
cwr1SecTxArqCount,
|
|
cwr1SecTxArqEventCount,
|
|
cwr1SecCorrectedSyncByteErrs,
|
|
cwr1SecConsecutiveCwErrs,
|
|
cwr1SecPostARQGoodCodewords
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Required Radio link metrics objects for the point to point wireless
|
|
systems."
|
|
::= { cwrRadioIfGroups 4 }
|
|
|
|
-- Required Test Group
|
|
cwrComplianceRadioTestGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrLocalLoopbackPoint,
|
|
cwrScopePortOn,
|
|
cwrScopePortDsp,
|
|
cwrScopePortAttribute
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in the point to point wireless
|
|
system for Testing the link."
|
|
::= { cwrRadioIfGroups 5 }
|
|
|
|
-- Optional History Gruop
|
|
cwrComplianceHistoryGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrHistClass,
|
|
cwrRfResourceId,
|
|
cwrDspNumber,
|
|
cwrStartBinValue,
|
|
cwrBinDelta,
|
|
cwrNumHistBins,
|
|
cwrUpdateRate,
|
|
cwrCollDuration,
|
|
cwrOwnerId,
|
|
cwrHistStatus,
|
|
cwrHistBitShift,
|
|
cwrHistToneSelection,
|
|
cwrHistToneValue,
|
|
cwrHistAction,
|
|
cwrHistRowStatus,
|
|
cwrHistPeriodicSum,
|
|
cwrHistUpdateTime,
|
|
cwrHistMin,
|
|
cwrHistMax,
|
|
cwrHistMean,
|
|
cwrValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in the point to point wireless
|
|
system for capturing histograms of radio signal parameters on the
|
|
radio interface."
|
|
::= { cwrRadioIfGroups 6 }
|
|
|
|
-- Optional Radio Timeline group.
|
|
cwrComplianceRadioTlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrThreshAttribute,
|
|
cwrThreshType,
|
|
cwrThreshAntId,
|
|
cwrThreshValue,
|
|
cwrThreshHysteresisTime,
|
|
cwrThreshLimitTime,
|
|
cwrThreshRowStatus,
|
|
cwrThreshDspNum,
|
|
cwrTlClass,
|
|
cwrTlRfResourceId,
|
|
cwrTlDspNum,
|
|
cwrTlNumDataValues,
|
|
cwrTlDecimationFactor,
|
|
cwrTlPreSumShift,
|
|
cwrTlToneSelection,
|
|
cwrTlToneValue,
|
|
cwrTlThreshIndex,
|
|
cwrTlAction,
|
|
cwrTlStatus,
|
|
cwrTlPostTrigBufMgmt,
|
|
cwrTlRowStatus,
|
|
cwrTlUpdateTime,
|
|
cwrTlNumValues,
|
|
cwrTlTriggerLoc,
|
|
cwrTlValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in the point to point wireless
|
|
system for establishing thresholds and capturing timeline data."
|
|
::= { cwrRadioIfGroups 7 }
|
|
|
|
-- Optional Snapshot group
|
|
cwrComplianceRadioSnapshotGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrSnapshotType,
|
|
cwrSnapshotAction,
|
|
cwrSnapshotStatus,
|
|
cwrSnapshotRowStatus,
|
|
cwrSnapAttr1Id,
|
|
cwrSnapAttr1Size,
|
|
cwrSnapAttr2Id,
|
|
cwrSnapAttr2Size,
|
|
cwrSnapAttr3Id,
|
|
cwrSnapAttr3Size,
|
|
cwrSnapAttr4Id,
|
|
cwrSnapAttr4Size,
|
|
cwrRealPart,
|
|
cwrImaginaryPart
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in the point to point wireless
|
|
system for capturing snapshots of various parameters on the radio
|
|
interface."
|
|
::= { cwrRadioIfGroups 8 }
|
|
|
|
-- Optional Antenna Group.
|
|
cwrComplianceRadioAntennaGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrAntennaXDim,
|
|
cwrAntennaYDim,
|
|
cwrAntennaType,
|
|
cwrAntennaDescr,
|
|
cwrAntennaGain,
|
|
cwrAntennaPolarization
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in the point to point wireless
|
|
system for managing the antennas available in the system."
|
|
::= { cwrRadioIfGroups 9 }
|
|
|
|
-- Optional Corrected Byte Error Group.
|
|
cwrComplianceRadioPhyByteErrGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cwrArq1ByteErrs,
|
|
cwrArq2ByteErrs,
|
|
cwrArq3ByteErrs,
|
|
cwrArq4ByteErrs,
|
|
cwrArq5ByteErrs,
|
|
cwrArq6ByteErrs,
|
|
cwrArq7ByteErrs,
|
|
cwrArq8ByteErrs,
|
|
cwrArq9ByteErrs
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in the point to point wireless
|
|
system for tracking the number of errored bytes that were
|
|
automatically corrected."
|
|
::= { cwrRadioIfGroups 10 }
|
|
|
|
cwrComplianceNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { cwrTrapConfigMismatch,
|
|
cwrTrapInitFailure,
|
|
cwrTrapLinkQuality,
|
|
cwrTrapLinkSyncLost,
|
|
cwrTrapLinkSyncAcquired,
|
|
cwrTrapIfRxOsc,
|
|
cwrTrapIfTxOsc,
|
|
cwrTrapIfRefOsc,
|
|
cwrTrapRfSupplyVoltage,
|
|
cwrTrapRfRxOsc,
|
|
cwrTrapRfTxOsc,
|
|
cwrTrapRfTemp,
|
|
cwrTrapRfStatusChange,
|
|
cwrTrapLink1HrThresh,
|
|
cwrTrapLink24HrThresh,
|
|
cwrTrapThresh
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of notifications. Note that none of these
|
|
notifications were originally defined with an OID
|
|
having 0 as its next-to-last sub-identifier. Therefore,
|
|
none of these notifications are reverse-mappable between
|
|
SNMPv1 and SNMPv2/SNMPv3."
|
|
::= { cwrRadioIfGroups 11 }
|
|
|
|
END
|
|
|
|
|