snmp_mib_archive/snmp_mib_archive/BASIS-GENERIC-MIB.my

1530 lines
42 KiB
Plaintext

-- *****************************************************************
-- BASIS Generic MIB
--
-- September 2002
--
-- Copyright (c) 1996-2001, 2002 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
--
-- LAST-UPDATED "200209240000Z"
-- DESCRIPTION
-- "The Card Generic mib containing generic information about
-- the service modules(Function Modules),back cards(Line Modules).
-- This contains information such as card type, back card type,
-- card status, back card status,serial number,
-- hardware revision, firmware version,reset reasons etc."
--
-- REVISION "200209240000Z"
-- DESCRIPTION
-- "Clarified the descriptions of some of the objects.
-- Added transId OBJECT-TYPE.
--
-- REVISION "200110150000Z"
-- DESCRIPTION
-- "Added following enumeration in <functionModuleType>
-- vism-pr-8T1 (563)
-- vism-pr-8E1 (564)
-- "
-- REVISION "200110020000Z"
-- DESCRIPTION
-- "Modified description for configChangeTypeBitMap.
-- Added configChangeParentObjectIndex,
-- configChangeGrandParentObjectIndex and
-- configChangeSMSpecificObject in
-- cardInformation Table
-- "
--
-- REVISION "200109240000Z"
-- DESCRIPTION
-- "Added following enumeration in <functionModuleType>
-- cesmB-8T1 (787)
-- "
--
-- REVISION "200109210000Z"
-- DESCRIPTION
-- "Added following enumerations in <functionModuleState>
-- notResponding(14)
-- cardinit(17)
-- "
--
-- REVISION "200108230000Z"
-- DESCRIPTION
-- CONTACT-INFO
-- " Cisco Systems
-- Customer Service
--
-- Postal: 170 W Tasman Drive
-- San Jose, CA 95134
-- USA
--
-- Tel: +1 800 553-NETS
--
-- E-mail: cs-wanatm@cisco.com"
-- "
BASIS-GENERIC-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter FROM RFC1155-SMI
OBJECT-TYPE FROM RFC-1212
DisplayString FROM RFC1213-MIB
cardGeneric FROM BASIS-MIB;
cardInformation OBJECT IDENTIFIER ::= { cardGeneric 1 }
cardInterface OBJECT IDENTIFIER ::= { cardGeneric 2 }
cardSelfTest OBJECT IDENTIFIER ::= { cardGeneric 3 }
-- ------------------------------------------------------------------
--
-- Group "cardInformation"
-- This group contains information which is generic to all cards in BASIS.
-- ------------------------------------------------------------------
moduleSlotNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot number this card is present
"
::= { cardInformation 1 }
-- function Module is also referred to as front card in some instances
--
functionModuleType OBJECT-TYPE
SYNTAX INTEGER {
other (1),
asc (2),
bnm-T3 (10),
bnm-E3 (11),
bnm-155 (12),
srm-4T1E1 (20),
srm-3T3 (21),
-- SRME
srme-1OC3 (22),
srme-1STS3(23),
srme-NOBC(24),
srm-3T3-NOBC(25),
frsm-4T1 (30),
frsm-4E1 (31),
frsm-4T1-C(32),
frsm-4E1-C(33),
-- HSSI
frsm-hs1 (34),
frsm-8T1 (35),
frsm-8E1 (36),
frsm-hs1b (37),
ausm-4T1 (40),
ausm-4E1 (41),
ausm-8T1 (50),
ausm-8E1 (51),
-- AUSM Model B
ausmB-8T1 (52),
ausmB-8E1 (53),
cesm-4T1 (60),
cesm-4E1 (61),
imatm-T3T1 (70),
imatm-E3E1 (71),
-- imatm model B
imatmB-8T1 (72),
imatmB-8E1 (73),
frasm-8T1 (80),
cesm-8T1 (90),
cesm-8E1 (91),
-- SM from Netro
bscsm-2 (100),
bscsm-4 (101),
-- testers
atmt-8T1 (110),
atmt-8E1 (111),
frt-8T1 (120),
frt-8E1 (121),
-- frsm_vhs cards
frsm-2ct3 (130),
frsm-2t3 (131),
frsm-2e3 (132),
frsm-hs2 (133),
frsm-2t3b (134),
frsm-2e3b (135),
frsm-hs2b-hssi (136),
frsm-hs2b-12In1 (137),
-- cesm_t3e3 cards
cesm-T3 (140),
cesm-E3 (141),
-- VISM
vism-8T1 (150),
vism-8E1 (151),
-- VISM PR
vism-pr-8T1 (563),
vism-pr-8E1 (564),
cesmB-8T1 (787),
pxm1 (1000),
pxm1-2t3e3 (1001),
pxm1-4oc3 (1002),
pxm1-oc12 (1003),
rpm (2000),
rpm-pr (2001)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object holds the type of the card. The card
can type is for Processor module as well as service module.
"
DEFVAL { other }
::= { cardInformation 2 }
functionModuleDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the card
"
::= { cardInformation 3 }
functionModuleSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..11))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial number of the function Module."
::= { cardInformation 4 }
functionModuleHWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hardware revision number for function Module."
::= { cardInformation 5 }
functionModuleFWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware revision number of the function Module."
::= { cardInformation 6 }
functionModuleState OBJECT-TYPE
SYNTAX INTEGER{
nocard (1),
standby (2),
active (3),
failed (4),
selfTest (5),
heldInReset (6),
boot (7),
mismatch (8),
unknown (9),
coreCardMisMatch (10),
blocked (11),
reserved (12),
hold (13),
notResponding (14),
cardinit (17)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object holds the status of a card in a particular shelf-slot.
The possible values are :
nocard(1) : card not present.
standby(2) : card in standby state. The card is in ready state
and will be ready to take over the service if
the corresponding active card(redundant)
fails.
active(3) : card in active state. The card is providing
the service.
failed(4) : card in failed state. The card can come out
of this state only after user intervention
(Reset or running some CLI commands).
selfTest(5) : online diagnostics is being run in card.
heldInReset(6) : The card configuration is being cleared.
No requests can be serviced.
boot(7) : card in boot state.
mismatch(8) : card is not compatible with the current
configuration. Card was correctly provisioned
earlier, however the card was replaced by
an incompatible card. This state can be
resolved by clearing the configuration, or
replacing with the appropriate card.
unknown(9) : could not determine the state
coreCardMisMatch(10) : Controller Card(PXM/ASC etc)
and SRM(Service Resource Module)
combination does not match.
blocked(11) : In case of 1:N redundancy configuration
the secondary card(backup card) is covering
one of the primary card and can not cover
any other card in the group if there is a failure.
Redundancy is blocked.
hold(13) : The standby controller card assumes the hold
state during PXM upgrades. In this state,
the standby PXM will be running a different
software but will be receiving all standby
updates(BRAM and Database). This state is
applicable only for MGX8250 Platform.
notResponding(14): Response from the Service Module has become
slow probably due to overloading of CPU.
No recovery action is required on user part.
At present, this state is applicable only
for Router Blade(RPM).
cardinit(17) : When the physical presence of card has been
detected but the communication hasn't yet
been established between the controller card
(PXM) and Service Module.
"
::= { cardInformation 7 }
functionModuleResetReason OBJECT-TYPE
SYNTAX INTEGER{
powerUp (1),
parityError (2),
watchDog (3),
resourceOverflow (4),
clrAllCnf (5),
missingTask (6),
pxmLowVoltage(7),
resetByEventLogTask(8),
resetFromShell(9),
unknown(10),
resetFromPXM(11),
resetSys(12),
switchCC(13),
sCacheError(14),
swError(15),
upgrade(16),
restoreAllCnf(17),
driverError(18)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last reason for card to reset.
The possible values are :
powerUp(1) : power up
parityError(2) : parity error
watchDog(3) : watchdog
resourceOverflow (4) : resource overflow
clrAllCnf (5) : configuration of the shelf is cleared.
missingTask (6) : task is missing
pxmLowVoltage(7): low voltage detected on PXM
resetByEventLogTask(8):
resetFromShell(9): command is run from command shell
unknown(10) :
resetFromPXM(11) : Controller Card(PXM) reset the card.
resetSys(12) : due to resetsys CLI Command.
switchCC(13) : due to switch over CLI command.
sCacheError(14) :
swError(15) : software error.
upgrade(16) : upgrade
restoreAllCnf(17): restore configuration.
driverError(18) : driver error.
Valid values for VISM:
powerUp, watchDog, resetFromShell and resetFromPXM.
"
::= { cardInformation 8 }
lineModuleType OBJECT-TYPE
SYNTAX INTEGER {
other (1),
lm-ASC (2),
lm-DB15-4T1 (16),
lm-DB15-4E1 (17),
lm-BNC-4E1 (18),
lm-DB15-4T1-R(19),
lm-DB15-4E1-R(20),
lm-BNC-4E1-R (21),
lm-RJ48-8T1 (22),
lm-RJ48-8E1 (23),
lm-SMB-8E1 (24),
lm-RJ48-T3T1 (25),
lm-RJ48-E3E1 (26),
lm-RJ48-T3E1 (27),
lm-SMB-E3E1 (28),
lm-RJ48-E3T1 (29),
lm-SMB-T3E1 (30),
lm-T3E3-D (32),
lm-T3E3-B (33),
lm-155-SMF (34),
lm-155-UTP (35),
lm-RJ48-8T1-R(48),
lm-RJ48-8E1-R(49),
lm-SMB-8E1-R (50),
lm-3T3-B (51),
-- HSSI/X.21
lm-HS1-4X21 (60),
lm-HS1-3HSSI (61),
-- HSSI/X.21
lm-HS1-4V35 (62),
lm-12In1-8s (63),
lm-BSCSM-2 (70),
lm-BSCSM-4 (71),
lm-BNC-2T3 (80),
lm-BNC-2E3 (81),
pxm-ui (500),
smfir-1-622 (501),
smflr-1-622 (502),
smfir15-1-622 (503),
smflr15-1-622 (504),
mmf-4-155 (505),
smfir-4-155 (506),
smflr-4-155 (507),
rj45-fe (511),
mmf-fe (512),
mmf-fddi (513),
smf-fddi (514),
rj45-4e (515),
pxm-ui-s3 (1006),
-- SRME back card
lm-srme-1OC3-smlr (1050),
lm-srme-1OC3-smir (1051),
lm-srme-1OC3-smb (1052)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the Line Module(back card) type.
Physically it is behind the backplane, normally with
connectors for physical devices.
These are specific to the front or functional modules.
"
DEFVAL { other }
::= { cardInformation 9 }
lineModuleDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains description of the line module."
::= { cardInformation 10 }
lineModuleSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..11))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains Serial number of the line module."
::= { cardInformation 11 }
lineModuleHWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains Hardware revision for line module."
::= { cardInformation 12 }
lineModuleFWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware revision for line module.
The current version does not have any
firmware, hence will always contains
zero length octet string."
::= { cardInformation 13 }
lineModuleState OBJECT-TYPE
SYNTAX INTEGER {
notPresent (1),
present (2),
invalid (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"line module status."
::= { cardInformation 14 }
moduleTrapAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER {
minor (1),
major (2),
dontCare (3),
critical (4),
error (5),
warning (6),
notice (7),
info (8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is sent to managers as part of all Trap PDUs, to
determine the module alarm severity. An implementation may
not support all the possible values.
The Possible values are :
major (1) : Major Service has been impacted
minor (2) : Minor Service has been lost
dontCare (3) : severity is not applicable
critical (4) : affects existing data traffic
error (5) : error has occurred
warning (6) : a threshold has been reached
notice (7) : a normal but significant event has occurred
info (8) : informational
"
::= { cardInformation 15 }
mibVersionNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MIB version number. Updated when any part of
the MIB changes.
"
DEFVAL { 2 }
::= { cardInformation 16 }
configChangeTypeBitMap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Configuration change Type BitMap
bit 0 set = Card Configuration Change
bit 1 set = Line Configuration Change
bit 2 set = Port Configuration Change
bit 3 set = Chan Configuration Change
bit 4 set = STUN protocol group configuration Change
bit 5 set = STUN port configuration Change
bit 6 set = STUN route configuration Change
bit 7 set = BSTUN protocol configuration Change
bit 8 set = BSTUN port configuration Change
bit 9 set = BSTUN route configuration Change
bit 10 set = FRASBNN route configuration Change
bit 11 set = FRASBAN route configuration Change
bit 12 set = SDLC port configuration Change
bit 13 set = SDLC LS configuration Change
bit 14 set = BSC port configuration Change
bit 15 set = LLC port configuration Change
bit 16 set = card LCN partition change (controller based only)
bit 17 set = port resource partition change (under any partition type)
bit 18 set = VISM Endpoint Configuration Change
bit 19 set = Egress Q configuration change
default value is 0, no change
This object makes sense only in traps. A GET
on this may not return a Useful result.
Bit 19 is not applicable for MGX 8850 Release 1.x.x
and MGX 8220
"
DEFVAL { 0 }
::= { cardInformation 17 }
configChangeObjectIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Configuration change object index, could be
line number or port number or channel number
depends on the type bitmap, for port resouce
partition change (bit 17), this index is actually
constructed by (portNum << 16 | controller)
because the table has two indices.
When the 'Line Configuration Change' bit is set,
the configChangeObjectIndex has the following special meanings
in IMATM and FRSM-2CT3 cards:
IMATM - configChangeObjectIndex range between 1..8
indicates that the configuration change refers
to the DS1 line index. A value of 9 indicates that
the configuration change refers to the DS3 line index.
FRSM-2CT3 - configChangeObjectIndex range between 1..56
indicates that the configuration change refers
to the DS1 line index. A value of (128 + n)
refers to DS3 line index numbered 'n'.
This object makes sense only in traps. A GET
on this may not return a Useful result.
"
::= { cardInformation 18 }
configChangeStatus OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is applicable only for traps.
The SNMP operation may not be meaningful.
The value contained in this object is same as
the value of the other objects which are used
for adding/deleting/modifying the row.
The possible values are
0 - No meaning and is not applicable.
1 - add [ Row added ]
2 - delete [ Row deleted ]
3 - mod [ Row modified ]
This value and value contained in configChangeTypeBitMap
represent the configuration change operation.
The default value is 0 and it does not
represent any status."
DEFVAL {0}
::= { cardInformation 19 }
cardIntegratedAlarmBitMap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit position represents the different types of alarm
for ASC:
bit 0: ShelfFunctionModuleState (BNM only)
(failed/boot/mismatch/heldinReset)
bit 1: LineModuleState (BNM only) (notPresent/invalid)
bit 2: ASMPhysicalAlarmState (BNM only)
bit 3: ATMLMIFailure (ASC only)
bit 4: LineAlarmState (BNM only)
bit 5: LineStatisticalAlarmState (BNM only)
bit 6: PLCPAlarmState (BNM only)
bit 7: PLCPStatisticalAlarmState (BNM only)
bit 8: SmConnectionFailureAlarm
for SM:
bit 0: ShelfFunctionModuleState
(failed/boot/mismatch/heldinReset)
bit 1: LineModuleState (notPresent/invalid)
bit 2: PortLMIFailure
bit 3: LineAlarmState
bit 4: LineStatisticalAlarmState
bit 5: FrameRelayPortState (RemoteLoopback/
FailedDueToLine/
FailedDueToSig)
bit 6: ChannelState
for PXM/SRM Only (MGX8850 Platfrom):
Only those marked with SRM are valid for both PXM/SRM.
The rest are valid only for PXM.
bit 0 : ShelfFunctionModuleState
bit 1 : Backcard Line Module (SRM/PXM)
This Alarm is generated when the Line Module
(Trunk Backcard) is removed or goes to a mismatch
state(or backcard type is unknown).
bit 2 : Backcard UIModule
This Alarm is generated when the UI backcard is
removed or goes to a mismatch state
(or backcard type is unknown).
bit 3 : ASM Physical Alarm
This specifies whether any of the
environmental monitoring components like
Temperature, Voltage Supply, Fan Speed
have gone into alarm.
bit 4 : ATM LMI Failure
bit 5 : Line Alarm (SRM/PXM)
bit 6 : Line Statistical Alarm (SRM/PXM)
bit 7 : Lines Alarm (SRM/PXM)
bit 8 : PLCP Alarm
bit 9 : PLCP Statistical Alarm
bit 10 : Connections exist on removed SM
bit 11 : Disk related Failure on first PXM slot
bit 12 : Disk related Failure on second PXM slot
The Disk Alarms are generated when any of the
file operations on Disk like open,read,write,
lseek etc fail.
VSM Alarms
bit 13 : Port LMI Failure
bit 14 : Port State Alarm
bit 15 : Channel Shelf Alarm
bit 16 : Taskmon Task Suspended
bit 17 : Excess Power Consumption
bit 30 : bit set(1) major alarm, else (0) minor alarm
"
DEFVAL {0}
::= { cardInformation 20 }
cleiCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Common Language Equipment(CLEI) Code.
"
::= { cardInformation 21 }
macAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet address (base address) stored in
NVRAM, entered by manfacturing.
"
::= { cardInformation 22 }
macAddrBlkSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address block size, entered by
manufacturing.
"
::= { cardInformation 23 }
finalTestTechnician OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Final Test Technician Employee Identification Number.
"
::= { cardInformation 24 }
hwFailures OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hardware failure code."
::= { cardInformation 25 }
hwHistory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RMA Test History - RMA Failure Code."
::= { cardInformation 26 }
secLineModuleType OBJECT-TYPE
SYNTAX INTEGER {
other (1),
lm-ASC (2),
lm-DB15-4T1 (16),
lm-DB15-4E1 (17),
lm-BNC-4E1 (18),
lm-DB15-4T1-R(19),
lm-DB15-4E1-R(20),
lm-BNC-4E1-R (21),
lm-RJ48-8T1 (22),
lm-RJ48-8E1 (23),
lm-SMB-8E1 (24),
lm-RJ48-T3T1 (25),
lm-RJ48-E3E1 (26),
lm-RJ48-T3E1 (27),
lm-SMB-E3E1 (28),
lm-RJ48-E3T1 (29),
lm-SMB-T3E1 (30),
lm-T3E3-D (32),
lm-T3E3-B (33),
lm-155-SMF (34),
lm-155-UTP (35),
lm-RJ48-8T1-R(48),
lm-RJ48-8E1-R(49),
lm-SMB-8E1-R (50),
lm-3T3-B (51),
lm-HS1-4X21 (60),
lm-HS1-3HSSI (61),
-- HSSI/X.21
lm-HS1-4V35 (62),
lm-12In1-8s (63),
lm-BSCSM-2 (70),
lm-BSCSM-4 (71),
lm-BNC-2T3 (80),
lm-BNC-2E3 (81),
pxm-ui (500),
smfir-1-622 (501),
smflr-1-622 (502),
smfir15-1-622 (503),
smflr15-1-622 (504),
mmf-4-155 (505),
smfir-4-155 (506),
smflr-4-155 (507),
rj45-fe (511),
mmf-fe (512),
mmf-fddi (513),
smf-fddi (514),
rj45-4e (515),
pxm-ui-s3 (1006)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the type of secondary
line module(back card).
Physically it is the bottom card behind the backplane.
Normally with connectors for physical devices.
These are specific to the front or function modules.
This Object is applicable only to selected MGX switches.
"
DEFVAL { other }
::= { cardInformation 27 }
secLineModuleDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the Secondary line module.
This Object is applicable only to selected MGX switches.
"
::= { cardInformation 28 }
secLineModuleSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..11))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial number of the secondary(bottom) line module.
This object is applicable only to selected MGX switches.
"
::= { cardInformation 29 }
secLineModuleHWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hardware revision for secondary (bottom) line module
This object is applicable only to selected MGX switches.
"
::= { cardInformation 30 }
secLineModuleFWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware revision for Secondary line module
This object is applicable only to selected MGX switches.
If there is no Firmware revision,
then this object returns 0.
"
::= { cardInformation 31 }
secLineModuleState OBJECT-TYPE
SYNTAX INTEGER {
notPresent (1),
present (2),
invalid (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"line module status of secondary (bottom) back card.
This object is applicable only to selected MGX switches."
::= { cardInformation 32 }
configChangeParentObjectIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Parent object index, could be
- line index
- port index
This object will indicate the index of the immediate
higher level object (line or port) of configChangeObjectIndex.
This object is applicable only when configChangeObjectIndex
represents a channel, port, egress Q or resource partition
index.
Following specifies the mapping between the
configChangeObjectIndex and its corresponding
configChangeParentObjectIndex.
configChangeObjectIndex configChangeParentObjectIndex
----------------------- -----------------------------
Port Index Line Index
Egress Q Index Port Index
Resource Partition Index Port Index
Channel Index Port Index
When the 'Port Configuration Change' bit is set,
the configChangeParentObjectIndex will represent
a 'Line Index' which in turn has the following
special meaning in FRSM-2CT3 cards.
- configChangeParentObjectIndex range between 1..56
indicates that the configuration change refers to the DS1 line
index. A value of (128 + n) refers to DS3 line index
numbered 'n'.
This object object is applicable only in traps.
A GET on this may not return a useful result.
This object Object is not applicable to MGX 8850
Release 1.x.x and MGX8220
"
::= { cardInformation 33 }
configChangeGrandParentObjectIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Grand Parent object index, could be
- line index
This object will indicate the index of the immediate
higher level object (line) of configChangeParentObjectIndex.
This object is applicable only when configChangeParentObjectIndex
represents a port index.
Following specifies the mapping between the
configChangeParentObjectIndex and its corresponding
configChangeGrandParentObjectIndex.
When the 'Port Configuration Change' bit is set
the configChangeGrandParentObjectIndex will represent
a 'Line Index' which in turn has the following
special meaning in FRSM-2CT3 cards.
- configChangeParentObjectIndex range between 1..56
indicates that the configuration change refers to the DS1 line
index. A value of (128 + n) refers to DS3 line index
numbered 'n'.
This object is applicable only in traps.
A GET on this may not return a useful result.
This object is not applicable to MGX 8850
release 1.x.x and MGX8220."
::= { cardInformation 34 }
configChangeSMSpecificObject OBJECT-TYPE
SYNTAX INTEGER (0..'ffffff'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" configChangeSMSpecificObject is a generic object
which is Service Module Specific. It can be used
for different purposes in different cards. The
usage of the same with regard to very card type is
listed below.
FRSM-8T1E1 - used to store portDs0ConfigBitMap
FRSM-VHS - used to store portDs0ConfigBitMap
CESM-8T1E1 - used to store cesPortDs0ConfigBitMap
CESM-T3E3 - not used
AUSM-8T1E1 - not used
This object is not applicable to MGX 8850
Release 1.x.x and MGX8220."
::= { cardInformation 35 }
transId OBJECT-TYPE
SYNTAX INTEGER (0..'7fffffff'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Per card transaction ID. This object is used to keep
track of configuration change on the card.
The transId will be incremented by one for every
configuration change on the card."
::= { cardInformation 36 }
-- ******************************************************************
--
-- Group "Interface"
-- This group contains list of physical interfaces and service types
-- available on a card.
-- Different line types are e.g. DS1,DS3,OC3 etc.
-- Different services are e.g. ATM,FrameRelay etc.
-- Any combination of line type and service type are possible for a card.
--
-- ******************************************************************
interfaceNumOfValidEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in interface Table
The number represents the physcial interfaces the module has.
"
::= { cardInterface 2 }
interfaceLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF InterfaceLineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table has list of the physical interfaces
and the services available on this module.
"
::= { cardInterface 1 }
interfaceLineEntry OBJECT-TYPE
SYNTAX InterfaceLineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry for physical interface
"
INDEX { interfaceLineNum }
::= { interfaceLineTable 1 }
InterfaceLineEntry ::=
SEQUENCE {
interfaceLineNum INTEGER,
interfaceLineType INTEGER,
interfaceNumOfPortsPerLine INTEGER,
interfaceServiceType INTEGER,
interfaceNumOfPVC INTEGER,
interfaceNumOfEgressQueue INTEGER
}
interfaceLineNum OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index to uniquely indentify the physical interface and service.
Indices 1..8 are used for VISM-8T1/E1.
"
::= { interfaceLineEntry 1 }
interfaceLineType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ds1(18),
e1(19),
ethernet-3Mbit (26),
ds3(30),
rs232(33),
v35(45),
-- HSSI/X.21
-- Unable to find for X.21 interface
hssi(46)
-- HSSI/X.21
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the type of interfaces provided by
this Module. These numbers are from RFC1700."
::= { interfaceLineEntry 2 }
interfaceNumOfPortsPerLine OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of physical ports of the line type.
VISM has a port, but is not linked to these physical lines,
hence value=0 is returned.
"
DEFVAL {672}
::= { interfaceLineEntry 3 }
interfaceServiceType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ethernet-3Mbit (26),
slip (28),
frameRelay(32),
atm(37),
voice(42)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The services available on the interfaceLineType object
"
::= { interfaceLineEntry 4 }
interfaceNumOfPVC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Max number of Permanent Virtual Channels available per physical
line (line as defined in interfaceLineType).
VISM has a PVC but is not linked to the lines,
hence value=0 is returned.
"
::= { interfaceLineEntry 5 }
interfaceNumOfEgressQueue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Max number of Queues per port.
Value=0 is returned for VISM card.
"
::= { interfaceLineEntry 6 }
-- ----------------------------------------------------------------
--
-- Group "cardTest"
-- The cardTest group contains self test results.
-- All cards in BASIS have this group defined.
--
-- ----------------------------------------------------------------
selfTestEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the self test state
1 ==> self test enabled
2 ==> self test disabled
"
DEFVAL { disable }
::= { cardSelfTest 1 }
selfTestPeriod OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interval (in minutes) for self test.
"
DEFVAL { 1 }
::= { cardSelfTest 2 }
selfTestState OBJECT-TYPE
SYNTAX INTEGER {
passed (1),
failed (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Self test results for the module.
"
::= { cardSelfTest 3 }
selfTestResultDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Self test Result description
"
::= { cardSelfTest 4 }
selfTestClrResultButton OBJECT-TYPE
SYNTAX INTEGER {
other (1),
clear (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used for clearing the result
of an online diagnostics(or other self tests)."
::= { cardSelfTest 5 }
controlMsgCounter OBJECT IDENTIFIER ::= { cardGeneric 4 }
riscXmtCtrlMsg OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of control Frames transmitted to SAR (from RISC)
maintained by RISC
"
::= { controlMsgCounter 1 }
riscRcvCtrlMsg OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of control Frames received from SAR (to RISC)
maintained by RISC
"
::= { controlMsgCounter 2 }
sarXmtCtrlMsg OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of control Frames transmitted to RISC from SAR
maintained by SAR (should be equal to (riscRcvCtrlMsg)
"
::= { controlMsgCounter 3 }
sarRcvCtrlMsg OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of control Frames received to SAR from RISC
maintained by SAR (should be equal to (riscXmtCtrlMsg)
"
::= { controlMsgCounter 4 }
sarCtrlMsgDiscLenErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total control (management) frames (for MGX8800) or
cells(for MGX8220) discarded due to illegal length error
"
::= { controlMsgCounter 5 }
sarCtrlMsgDiscCRCErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total control (management) frames (MGX8800) or cells(MGX8220)
discard due to illegal CRC error.
"
::= { controlMsgCounter 6 }
sarCtrlMsgDiscUnknownChan OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of discarded control message due to unknown channel error."
::= { controlMsgCounter 7 }
sarCtrlMsgLastUnkownChan OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The control cell header Rcvd of the last unknown channel."
::= { controlMsgCounter 8 }
ctrlMsgClrButton OBJECT-TYPE
SYNTAX INTEGER {
other (1),
clear (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used for clearing the messages
in controlMsgCounter group."
::= { controlMsgCounter 9 }
sarChannelCounter OBJECT IDENTIFIER ::= { cardGeneric 5 }
-- ----------------------------------------------------------------
--
-- Group "sarCounters"
-- This group contains list of SAR counters and RISC counters
-- This group is common to all cards. All cards in BASIS have
-- SAR and RISC counters.
--
-- ----------------------------------------------------------------
-- ---------------------------------------------------------------------
--
-- SAR channel counters group
--
-- These are counter maintained by the SAR and supplied to the
-- manager by RISC, the counters are per VC and counters are
-- for ATM cells
--
-- cell counters
-- ---------------------------------------------------------------------
chanNumOfValidEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of entries in the sar channel table
"
::= { sarChannelCounter 2 }
sarChannelCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF SarChannelCounterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table is for logical channels
This table contains the counters for cells
transmitted on each channel."
::= { sarChannelCounter 1 }
sarChannelCounterEntry OBJECT-TYPE
SYNTAX SarChannelCounterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry for logical channel
"
INDEX { sarShelfNum, sarSlotNum, sarChanNum }
::= { sarChannelCounterTable 1 }
SarChannelCounterEntry ::=
SEQUENCE {
sarShelfNum INTEGER,
sarSlotNum INTEGER,
sarChanNum INTEGER,
-- Xmt Cell stats
xmtCells Counter,
xmtCellsCLP Counter,
xmtCellsAIS Counter,
xmtCellsFERF Counter,
xmtCellsBCM Counter,
xmtCellsEnd2EndLpBk Counter,
xmtCellsSegmentLpBk Counter,
xmtCellsDiscShelfAlarm Counter,
-- Rcv Cell stats
rcvCells Counter,
rcvCellsCLP Counter,
rcvCellsAIS Counter,
rcvCellsFERF Counter,
rcvCellsBCM Counter,
rcvCellsEnd2EndLpBk Counter,
rcvCellsSegmentLpBk Counter,
rcvCellsDiscOAM Counter,
sarClrButton INTEGER
}
sarShelfNum OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Shelf number
"
::= { sarChannelCounterEntry 1 }
sarSlotNum OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot number, the slot and shelf info is required here
because BSC sends the OAM cells for the FRSM cards
that have failed BSC could have upto 4000 connections
in this table."
::= { sarChannelCounterEntry 2 }
sarChanNum OBJECT-TYPE
SYNTAX INTEGER (0..4015)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BSC could have upto 4000 connections in this table
"
::= { sarChannelCounterEntry 3 }
xmtCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cells transmitted on this channel.
"
::= { sarChannelCounterEntry 4 }
xmtCellsCLP OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of CLP cells that were
transmitted on this channel."
::= { sarChannelCounterEntry 5 }
xmtCellsAIS OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of AIS cells that were transmitted on this channel.
"
::= { sarChannelCounterEntry 6 }
xmtCellsFERF OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of FERF cells that were transmitted on this channel.
"
::= { sarChannelCounterEntry 7 }
xmtCellsBCM OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of BCM cells that were transmitted on this channel."
::= { sarChannelCounterEntry 8 }
xmtCellsEnd2EndLpBk OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of End2End loop cells that were transmitted on
this channel."
::= { sarChannelCounterEntry 9 }
xmtCellsSegmentLpBk OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of segment loop cells that were transmitted
on this channel."
::= { sarChannelCounterEntry 10 }
xmtCellsDiscShelfAlarm OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cells discard due to Shelfalarm on this channel.
"
::= { sarChannelCounterEntry 11 }
-- receiver cell counters
rcvCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cells that were received on this channel.
"
::= { sarChannelCounterEntry 12 }
rcvCellsCLP OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of CLP cells that were received on this channel.
"
::= { sarChannelCounterEntry 13 }
rcvCellsAIS OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of AIS cells that were received on this channel.
"
::= { sarChannelCounterEntry 14 }
rcvCellsFERF OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of FERF cells that were received on this channel.
"
::= { sarChannelCounterEntry 15 }
rcvCellsBCM OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of BCM cells that were received on this channel.
"
::= { sarChannelCounterEntry 16 }
rcvCellsEnd2EndLpBk OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of End2End loop cells that were received on
this channel."
::= { sarChannelCounterEntry 17 }
rcvCellsSegmentLpBk OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of segment loop cells that were received on
this channel. "
::= { sarChannelCounterEntry 18 }
rcvCellsDiscOAM OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cells that had CRC error on
OAM cells
"
::= { sarChannelCounterEntry 19 }
sarClrButton OBJECT-TYPE
SYNTAX INTEGER {
other (1),
clear (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"clear the counters in the table
"
::= { sarChannelCounterEntry 20 }
END