mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-17 16:03:04 +00:00
709 lines
26 KiB
INI
Executable File
709 lines
26 KiB
INI
Executable File
#-MIBFILE: cpqthrsh.mib
|
|
|
|
CPQTHRSH-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
DisplayString ::=
|
|
OCTET STRING
|
|
|
|
PhysAddress ::=
|
|
OCTET STRING
|
|
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
system OBJECT IDENTIFIER ::= { mib-2 1 }
|
|
sysName OBJECT IDENTIFIER ::= { system 5 }
|
|
cpqHostOs OBJECT IDENTIFIER ::= { compaq 11 }
|
|
cpqHoComponent OBJECT IDENTIFIER ::= { cpqHostOs 2 }
|
|
cpqHoTrapInfo OBJECT IDENTIFIER ::= { cpqHoComponent 11 }
|
|
cpqHoTrapFlags OBJECT IDENTIFIER ::= { cpqHoTrapInfo 1 }
|
|
cpqThresholdMgmt OBJECT IDENTIFIER ::= { compaq 10 }
|
|
|
|
cpqMeMibRev OBJECT IDENTIFIER ::= { cpqThresholdMgmt 1 }
|
|
|
|
cpqMeComponent OBJECT IDENTIFIER ::= { cpqThresholdMgmt 2 }
|
|
|
|
cpqMeInterface OBJECT IDENTIFIER ::= { cpqMeComponent 1 }
|
|
|
|
cpqMeAlarm OBJECT IDENTIFIER ::= { cpqMeComponent 2 }
|
|
|
|
cpqMeOsCommon OBJECT IDENTIFIER ::= { cpqMeInterface 4 }
|
|
|
|
cpqMeMibRevMajor OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Major Revision level of the MIB.
|
|
|
|
A change in the major revision level represents a major change
|
|
in the architecture of the MIB. A change in the major revision
|
|
level may indicate a significant change in the information
|
|
supported and/or the meaning of the supported information,
|
|
correct interpretation of data may require a MIB document with
|
|
the same major revision level."
|
|
::= { cpqMeMibRev 1 }
|
|
|
|
|
|
cpqMeMibRevMinor OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Minor Revision level of the MIB.
|
|
|
|
A change in the minor revision level may represent some minor
|
|
additional support, no changes to any pre-existing information
|
|
has occurred."
|
|
::= { cpqMeMibRev 2 }
|
|
|
|
|
|
cpqMeMibCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The overall condition.
|
|
|
|
This object represents the overall status of the
|
|
threshold management system represented by this MIB."
|
|
::= { cpqMeMibRev 3 }
|
|
|
|
|
|
cpqMeOsCommonPollFreq OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Insight Agent's minimum polling frequency.
|
|
|
|
The minimum frequency, in seconds, at which the Insight Agent
|
|
will permit the cpqMeAlarmInterval to be SET (for an entry in
|
|
the cpqMeAlarm table). Changing this variable to smaller values
|
|
will allow a management station to modify or add entries in the
|
|
cpqMeAlarm table that can have smaller cpqMeAlarmInterval values
|
|
and will therefore be polled more frequently. An agent may also
|
|
choose to fail any request to change the poll frequency to a
|
|
value that would severely impact system performance."
|
|
::= { cpqMeOsCommon 1 }
|
|
|
|
|
|
cpqMeOsCommonModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqMeOsCommonModuleEntry
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "A table of software modules that provide an interface to the
|
|
device this MIB describes."
|
|
::= { cpqMeOsCommon 2 }
|
|
|
|
|
|
cpqMeOsCommonModuleEntry OBJECT-TYPE
|
|
SYNTAX CpqMeOsCommonModuleEntry
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "A description of a software modules that provide an interface
|
|
to the device this MIB describes."
|
|
INDEX { cpqMeOsCommonModuleIndex }
|
|
|
|
::= { cpqMeOsCommonModuleTable 1 }
|
|
|
|
cpqMeOsCommonModuleEntry ::=
|
|
SEQUENCE {
|
|
cpqMeOsCommonModuleIndex INTEGER,
|
|
cpqMeOsCommonModuleName DisplayString,
|
|
cpqMeOsCommonModuleVersion DisplayString,
|
|
cpqMeOsCommonModuleDate OCTET STRING,
|
|
cpqMeOsCommonModulePurpose DisplayString
|
|
}
|
|
|
|
cpqMeOsCommonModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "A unique index for this module description."
|
|
::= { cpqMeOsCommonModuleEntry 1 }
|
|
|
|
|
|
cpqMeOsCommonModuleName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The module name."
|
|
::= { cpqMeOsCommonModuleEntry 2 }
|
|
|
|
|
|
cpqMeOsCommonModuleVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..5))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The module version in XX.YY format.
|
|
|
|
Where XX is the major version number and YY is the minor version
|
|
number. This field will be a null (size 0) string if the agent
|
|
cannot provide the module version."
|
|
::= { cpqMeOsCommonModuleEntry 3 }
|
|
|
|
|
|
cpqMeOsCommonModuleDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(7))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The module date.
|
|
|
|
field octets contents range
|
|
===== ====== ======= =====
|
|
1 1-2 year 0..65536
|
|
2 3 month 1..12
|
|
3 4 day 1..31
|
|
4 5 hour 0..23
|
|
5 6 minute 0..59
|
|
6 7 second 0..60
|
|
(use 60 for leap-second)
|
|
|
|
|
|
This field will be set to year = 0 if the agent cannot provide
|
|
the module date. The hour, minute, and second field will be set
|
|
to zero (0) if they are not relevant. The year field is set
|
|
with the most significant octet first."
|
|
::= { cpqMeOsCommonModuleEntry 4 }
|
|
|
|
|
|
cpqMeOsCommonModulePurpose OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The purpose of the module described in this entry."
|
|
::= { cpqMeOsCommonModuleEntry 5 }
|
|
|
|
|
|
cpqMeAlarmNextIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The index of the next available entry in the cpqMeAlarm
|
|
table. If the maximum number of entries to the cpqMeAlarm
|
|
table has been reached, this index will contain -1."
|
|
::= { cpqMeAlarm 1 }
|
|
|
|
|
|
cpqMeAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqMeAlarmEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of alarm entries."
|
|
::= { cpqMeAlarm 2 }
|
|
|
|
|
|
cpqMeAlarmEntry OBJECT-TYPE
|
|
SYNTAX CpqMeAlarmEntry
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of parameters that set up a periodic checking
|
|
for alarm conditions."
|
|
INDEX { cpqMeAlarmIndex }
|
|
|
|
::= { cpqMeAlarmTable 1 }
|
|
|
|
cpqMeAlarmEntry ::=
|
|
SEQUENCE {
|
|
cpqMeAlarmIndex INTEGER,
|
|
cpqMeAlarmInterval INTEGER,
|
|
cpqMeAlarmVariable OBJECT IDENTIFIER,
|
|
cpqMeAlarmSampleType INTEGER,
|
|
cpqMeAlarmValue INTEGER,
|
|
cpqMeAlarmStartupAlarm INTEGER,
|
|
cpqMeAlarmRisingThreshold INTEGER,
|
|
cpqMeAlarmFallingThreshold INTEGER,
|
|
cpqMeAlarmPermanence INTEGER,
|
|
cpqMeAlarmOwner DisplayString,
|
|
cpqMeAlarmStatus INTEGER,
|
|
cpqMeAlarmSeverity INTEGER,
|
|
cpqMeAlarmExtendedDescription DisplayString
|
|
}
|
|
|
|
cpqMeAlarmIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "An index that uniquely identifies an entry in the
|
|
cpqMeAlarm table. Each such entry defines a
|
|
diagnostic sample at a particular interval
|
|
for an object on the device."
|
|
::= { cpqMeAlarmEntry 1 }
|
|
|
|
|
|
cpqMeAlarmInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The interval, in seconds, between consecutive samples of
|
|
the data. When setting this variable, care should be given
|
|
to ensure that the variable being monitored will not exceed
|
|
2^31 - 1 and roll over.
|
|
|
|
The first sample will be taken immediately upon the
|
|
cpqMeAlarmStatus being set to valid(1).
|
|
|
|
This object may not be modified if the associated
|
|
cpqMeAlarmStatus object is equal to valid(1)."
|
|
::= { cpqMeAlarmEntry 2 }
|
|
|
|
|
|
cpqMeAlarmVariable OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The object identifier of the particular variable to be
|
|
sampled. Only variables that resolve to an ASN.1 primitive
|
|
type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks) may
|
|
be sampled.
|
|
|
|
Because SNMP access control is articulated entirely
|
|
in terms of the contents of MIB views, no access
|
|
control mechanism exists that can restrict the value of
|
|
this object to identify only those objects that exist
|
|
in a particular MIB view. Because there is thus no
|
|
acceptable means of restricting the read access that
|
|
could be obtained through the alarm mechanism, the
|
|
agent must only grant write access to this object in
|
|
those views that have read access to all objects on
|
|
the agent.
|
|
|
|
During a set operation, if the supplied variable
|
|
name is not available in the selected MIB view, a
|
|
badValue error must be returned. If at any time
|
|
the variable name of an established cpqMeAlarmEntry is
|
|
no longer available in the selected MIB view, the
|
|
agent must change the status of this cpqMeAlarmEntry
|
|
to tempUnavailable(5).
|
|
|
|
This object may not be modified if the associated
|
|
cpqMeAlarmStatus object is equal to valid(1)."
|
|
::= { cpqMeAlarmEntry 3 }
|
|
|
|
|
|
cpqMeAlarmSampleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
absoluteValue(1),
|
|
deltaValue(2),
|
|
absSuppressRisingTrap(3),
|
|
absSuppressFallingTrap(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The method of sampling the selected variable and
|
|
calculating the value to be compared against the
|
|
thresholds.
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
absoluteValue(1), the most recent sampled value of
|
|
the selected variable (cpqMeAlarmVariable) will be
|
|
compared directly with the thresholds
|
|
(cpqMeAlarmRisingThreshold and cpqMeAlarmFallingThreshold).
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
deltaValue(2), the most recently sampled value minus
|
|
the previous sampled value is compared with the threshold
|
|
values (cpqMeAlarmRisingThreshold and
|
|
cpqMeAlarmFallingThreshold).
|
|
|
|
If the sample type is absSupressRisingValue(3), only
|
|
comparisons with the cpqMeAlarmFallingThreshold are
|
|
performed. If the sample type is absSupressFallingValue(4),
|
|
only comparisons with the cpqMeAlarmRisingThreshold are
|
|
performed.
|
|
|
|
This object may not be modified if the associated
|
|
cpqMeAlarmStatus object is equal to valid(1)."
|
|
::= { cpqMeAlarmEntry 4 }
|
|
|
|
|
|
cpqMeAlarmValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The value of the object identifier (cpqMeAlarmVariable)
|
|
during the last sampling period. The value during the
|
|
current sampling period is not made available until
|
|
the period is completed.
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
absoluteValue(1), absSupressRisingValue(3), or
|
|
absSupressFallingValue(4), the value (cpqMeAlarmValue)
|
|
should become the actual value obtained during this
|
|
sampling period.
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
deltaValue(2), the value (cpqMeAlarmValue) should
|
|
become the most recently sampled value minus the
|
|
previous sample (cpqMeAlarmValue)."
|
|
::= { cpqMeAlarmEntry 5 }
|
|
|
|
|
|
cpqMeAlarmStartupAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
risingAlarm(1),
|
|
fallingAlarm(2),
|
|
risingOrFallingAlarm(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The alarm that may be sent when this entry is first
|
|
set to valid.
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
absoluteValue(1), then the following comparisons are
|
|
used to generate an event.
|
|
|
|
If cpqMeAlarmStartupAlarm is equal to risingAlarm(1) or
|
|
risingOrFallingAlarm(3), then a single event will be
|
|
generated if the first sample after this entry becomes
|
|
valid is greater than or equal to this threshold. If
|
|
cpqMeAlarmStartupAlarm is equal to fallingAlarm(2) or
|
|
risingOrFallingAlarm(3), then a single event will be
|
|
generated if the first sample after this entry becomes
|
|
valid is less than or equal to this threshold.
|
|
|
|
This object may not be modified if the associated
|
|
cpqMeAlarmStatus object is equal to valid(1)."
|
|
::= { cpqMeAlarmEntry 6 }
|
|
|
|
|
|
cpqMeAlarmRisingThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A threshold for the sampled object identifier
|
|
(cpqMeAlarmVariable).
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
absoluteValue(1), then the following describes the
|
|
comparison. When the current sampled value is greater
|
|
than or equal to this threshold, and the value
|
|
(cpqMeAlarmValue) at the last sampling interval was
|
|
less than this threshold, a single event will be generated.
|
|
If cpqMeAlarmStartupAlarm is equal to risingAlarm(1) or
|
|
risingOrFallingAlarm(3), then a single event will be
|
|
generated if the first sample after this entry becomes
|
|
valid is greater than or equal to this threshold.
|
|
After a rising event is generated, another such event
|
|
will not be generated until the sampled value
|
|
falls below this threshold and reaches the falling
|
|
threshold (cpaMeAlarmFallingThreshold).
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
deltaValue(2), then the following describes the
|
|
comparison. When the most recently sampled value minus
|
|
the previous sampled value is greater than or equal to
|
|
the threshold (cpqMeAlarmRisingThreshold), and the
|
|
current alarm value (cpqMeAlarmValue) is less than the
|
|
threshold value (cpqMeAlarmRisingThreshold) a single
|
|
event will be generated. After a rising event is
|
|
generated, another such event will not be generated
|
|
until the most recently sampled value minus the previous
|
|
sampled value falls below this threshold
|
|
(cpqMeAlarmRisingThreshold) and reaches the falling
|
|
threshold (cpqMeAlarmFallingThreshold).
|
|
|
|
This object may not be modified if the associated
|
|
cpqMeAlarmStatus object is equal to valid(1)."
|
|
::= { cpqMeAlarmEntry 7 }
|
|
|
|
|
|
cpqMeAlarmFallingThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "A threshold for the sampled object identifier
|
|
(cpqMeAlarmVariable).
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
absoluteValue(1), then the following describes the
|
|
comparison. When the current sampled value is less
|
|
than or equal to this threshold, and the value
|
|
(cpqMeAlarmValue) at the last sampling interval was
|
|
greater than this threshold, a single event will be
|
|
generated. If cpqMeAlarmStartupAlarm is equal to
|
|
fallingAlarm(2) or risingOrFallingAlarm(3), then a
|
|
single event will be generated if the first sample after
|
|
this entry becomes valid is less than or equal to this
|
|
threshold. After a falling event is generated, another
|
|
such event will not be generated until the sampled value
|
|
rises above this threshold and reaches the rising
|
|
threshold (cpaMeAlarmRisingThreshold).
|
|
|
|
If the sample type (cpqMeAlarmSampleType) is
|
|
deltaValue(2), then the following describes the
|
|
comparison. When the most recently sampled value minus
|
|
the previous sampled value is less than or equal to
|
|
the threshold (cpqMeAlarmFallingThreshold), and the
|
|
current alarm value (cpqMeAlarmValue) is greater than the
|
|
threshold value (cpqMeAlarmFallingThreshold) a single
|
|
event will be generated. After a falling event is
|
|
generated, another such event will not be generated
|
|
until the most recently sampled value minus the previous
|
|
sampled value rises above this threshold
|
|
(cpqMeAlarmFallingThreshold) and reaches the rising
|
|
threshold (cpqMeAlarmRisingThreshold).
|
|
|
|
This object may not be modified if the associated
|
|
cpqMeAlarmStatus object is equal to valid(1)."
|
|
::= { cpqMeAlarmEntry 8 }
|
|
|
|
|
|
cpqMeAlarmPermanence OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temporary(1),
|
|
permanent(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies if the threshold management software should
|
|
recreate this entry if it is brought down and then
|
|
restarted. A temporary entry will not be recreated after a
|
|
restart. A permanent entry will be recreated after a
|
|
restart and requires an explicit invalidation to be
|
|
removed."
|
|
::= { cpqMeAlarmEntry 9 }
|
|
|
|
|
|
cpqMeAlarmOwner OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The entity that configured this entry and is
|
|
therefore using the resources assigned to it.
|
|
|
|
This string is used to model an administratively
|
|
assigned name of the owner of a resource. This
|
|
information is taken from the NVT ASCII character set.
|
|
It is suggested that this name contain one or more
|
|
of the following:
|
|
IP address, management station name, network manager's
|
|
name, location, or phone number.
|
|
In some cases the agent itself will be the owner of
|
|
an entry. In these cases, this string shall be set
|
|
to a string starting with 'monitor'.
|
|
|
|
SNMP access control is articulated entirely in terms of
|
|
the contents of MIB views; access to a particular SNMP
|
|
object instance depends only upon its presence or
|
|
absence in a particular MIB view and never upon its
|
|
value or the value of related object instances. Thus,
|
|
objects of this type afford resolution of resource
|
|
contention only among cooperating managers; they
|
|
realize no access control function with respect
|
|
to uncooperative parties."
|
|
::= { cpqMeAlarmEntry 10 }
|
|
|
|
|
|
cpqMeAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
createRequest(2),
|
|
underCreation(3),
|
|
invalid(4),
|
|
tempUnavailable(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The status of this alarm entry.
|
|
|
|
Setting this object to the value invalid(4) has the
|
|
effect of invalidating the corresponding entry.
|
|
That is, it effectively disassociates the mapping
|
|
identified with said entry.
|
|
It is an implementation-specific matter as to whether
|
|
the agent removes an invalidated entry from the table.
|
|
Accordingly, management stations must be prepared to
|
|
receive tabular information from agents that corresponds
|
|
to entries currently not in use. Proper
|
|
interpretation of such entries requires examination
|
|
of the relevant cpqMeAlarmStatus object.
|
|
|
|
An existing instance of this object cannot be set to
|
|
createRequest(2). This object may only be set to
|
|
createRequest(2) when this instance is created. When
|
|
this object is created, the agent may wish to create
|
|
supplemental object instances to complete a conceptual
|
|
row in this table. Immediately after completing the
|
|
create operation, the agent must set this object to
|
|
underCreation(3).
|
|
|
|
Entries shall exist in the underCreation(3) state until
|
|
the management station is finished configuring the
|
|
entry and sets this object to valid(1) or aborts,
|
|
setting this object to invalid(4). The agent will
|
|
deny a request to modify an underCreation(3) entry to
|
|
be that of createRequest(2) in order to lessen problems
|
|
arising when multiple management stations may be trying
|
|
to add an entry with the same index. If the agent
|
|
determines that an entry has been in the
|
|
underCreation(3) state for an abnormally long time,
|
|
it may decide that the management station has
|
|
crashed. If the agent makes this decision,
|
|
it may set this object to invalid(4) to reclaim the
|
|
entry. A prudent agent will understand that the
|
|
management station may need to wait for human input
|
|
and will allow for that possibility in its
|
|
determination of this abnormally long period.
|
|
|
|
If the agent has an entry which is valid(4) and it
|
|
is unable to query the particular ASN.1 object specified,
|
|
the agent should set the status to tempUnavailable(5).
|
|
The agent should continue to query that ASN.1 object,
|
|
and upon a successful query, the agent should set the
|
|
status back to valid(4)."
|
|
::= { cpqMeAlarmEntry 11 }
|
|
|
|
|
|
cpqMeAlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
normal(2),
|
|
minor(3),
|
|
warning(4),
|
|
major(5),
|
|
critical(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This is used to correlate the severity of a particular alarm
|
|
entry. The management console can use this to relate the
|
|
severity of an alarm entry to the end user."
|
|
::= { cpqMeAlarmEntry 12 }
|
|
|
|
|
|
cpqMeAlarmExtendedDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This string contains meaningful information about the MIB
|
|
variable which has the threshold set upon it. This information
|
|
will be bound to a trap and is intended to allow a management
|
|
console to have specific customized information about the MIB
|
|
variable which caused the trap."
|
|
::= { cpqMeAlarmEntry 13 }
|
|
|
|
|
|
cpqMe2RisingAlarm TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqMeAlarmVariable, cpqMeAlarmSampleType, cpqMeAlarmValue, cpqMeAlarmRisingThreshold, cpqMeAlarmOwner }
|
|
--#SUMMARY "%s: Variable %s has value %d >= %d."
|
|
--#ARGUMENTS {6,2,4,5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V3V#Threshold Variable: # $V4V#Threshold Type: # $V5V#Current Value: # $V6V#Threshold Top: # $V7V#Threshold Owner: #"
|
|
--#TYPE "Rising Threshold Passed (10003)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Threshold Events"
|
|
DESCRIPTION "Rising Threshold passed. An alarm entry has crossed its rising threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap."
|
|
::= 10003
|
|
|
|
|
|
cpqMeCriticalFallingAlarmExtended TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqMeAlarmVariable, cpqMeAlarmSampleType, cpqMeAlarmValue, cpqMeAlarmFallingThreshold, cpqMeAlarmOwner, cpqMeAlarmSeverity, cpqMeAlarmExtendedDescription }
|
|
--#SUMMARY "%s: Variable %s has value %d <= %d."
|
|
--#ARGUMENTS {6,2,4,5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V3V#Threshold Variable: # $V4V#Threshold Type: # $V5V#Current Value: # $V6V#Threshold Top: # $V7V#Threshold Owner: # V8V#Severity: # V9V#Description: #"
|
|
--#TYPE "Critical Falling Threshold Passed (10008)"
|
|
--#CATEGORY "Proliant Threshold Events"
|
|
DESCRIPTION "Critical Falling Threshold passed. An alarm entry has crossed its Critical falling threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap."
|
|
::= 10008
|
|
|
|
|
|
cpqMeCriticalRisingAlarmExtended TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqMeAlarmVariable, cpqMeAlarmSampleType, cpqMeAlarmValue, cpqMeAlarmRisingThreshold, cpqMeAlarmOwner, cpqMeAlarmSeverity, cpqMeAlarmExtendedDescription }
|
|
--#SUMMARY "%s: Variable %s has value %d >= %d."
|
|
--#ARGUMENTS {6,2,4,5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V9V#Description: # $V8V#Severity Level: # $V5V#Current Value: # $V6V#Threshold Top: # $V7V#Threshold Owner: #"
|
|
--#TYPE "Critical Rising Threshold Passed (10007)"
|
|
--#CATEGORY "Proliant Threshold Events"
|
|
DESCRIPTION "Critical Rising Threshold passed. An alarm entry has crossed its Critical rising threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap."
|
|
::= 10007
|
|
|
|
|
|
cpqMe2FallingAlarm TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqMeAlarmVariable, cpqMeAlarmSampleType, cpqMeAlarmValue, cpqMeAlarmFallingThreshold, cpqMeAlarmOwner }
|
|
--#SUMMARY "%s: Variable %s has value %d <= %d."
|
|
--#ARGUMENTS {6,2,4,5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V3V#Threshold Variable: # $V4V#Threshold Type: # $V5V#Current Value: # $V6V#Threshold Bottom: # $V7V#Threshold Owner: #"
|
|
--#TYPE "Falling Threshold Passed (10004)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Threshold Events"
|
|
DESCRIPTION "Falling Threshold passed. An alarm entry has crossed its falling threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap."
|
|
::= 10004
|
|
|
|
|
|
cpqMeFallingAlarm TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqMeAlarmVariable, cpqMeAlarmSampleType, cpqMeAlarmValue, cpqMeAlarmFallingThreshold, cpqMeAlarmOwner }
|
|
--#SUMMARY "%s: Variable %s has value %d <= %d."
|
|
--#ARGUMENTS {4,0,2,3}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V3V#Threshold Variable: # $V4V#Threshold Type: # $V5V#Current Value: # $V6V#Threshold Bottom: # $V7V#Threshold Owner: # $V8V#Severity Level: # $V9V#Description: #"
|
|
--#TYPE "Falling Threshold Passed (10002)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Threshold Events"
|
|
DESCRIPTION "Falling Threshold passed. An alarm entry has crossed its falling threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap."
|
|
::= 10002
|
|
|
|
|
|
cpqMeRisingAlarm TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqMeAlarmVariable, cpqMeAlarmSampleType, cpqMeAlarmValue, cpqMeAlarmRisingThreshold, cpqMeAlarmOwner }
|
|
--#SUMMARY "%s: Variable %s has value %d >= %d."
|
|
--#ARGUMENTS {4,0,2,3}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V1V#Threshold Variable: # $V2V#Threshold Type: # $V3V#Current Value: # $V4V#Threshold Top: # $V5V#Threshold Owner: #"
|
|
--#TYPE "Rising Threshold Passed (10001)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Threshold Events"
|
|
DESCRIPTION "Rising Threshold passed. An alarm entry has crossed its rising threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap."
|
|
::= 10001
|
|
|
|
|
|
cpqMeFallingAlarmExtended TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqMeAlarmVariable, cpqMeAlarmSampleType, cpqMeAlarmValue, cpqMeAlarmFallingThreshold, cpqMeAlarmOwner, cpqMeAlarmSeverity, cpqMeAlarmExtendedDescription }
|
|
--#SUMMARY "%s: Variable %s has value %d <= %d."
|
|
--#ARGUMENTS {6,2,4,5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V9V#Description: # $V8V#Severity Level: # $V5V#Current Value: # $V6V#Threshold Bottom: # $V7V#Threshold Owner: #"
|
|
--#TYPE "Falling Threshold Passed (10006)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Threshold Events"
|
|
DESCRIPTION "Falling Threshold passed. An alarm entry has crossed its falling threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap."
|
|
::= 10006
|
|
|
|
|
|
cpqMeRisingAlarmExtended TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqMeAlarmVariable, cpqMeAlarmSampleType, cpqMeAlarmValue, cpqMeAlarmRisingThreshold, cpqMeAlarmOwner, cpqMeAlarmSeverity, cpqMeAlarmExtendedDescription }
|
|
--#SUMMARY "%s: Variable %s has value %d >= %d."
|
|
--#ARGUMENTS {6,2,4,5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#MSG_FORMATTER "$V9V#Description: # $V8V#Severity Level: # $V5V#Current Value: # $V6V#Threshold Top: # $V7V#Threshold Owner: #"
|
|
--#TYPE "Rising Threshold Passed (10005)"
|
|
--#ENABLE true
|
|
--#CATEGORY "Proliant Threshold Events"
|
|
DESCRIPTION "Rising Threshold passed. An alarm entry has crossed its rising threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap."
|
|
::= 10005
|
|
|
|
|
|
END
|