#-MIBFILE: cpqrpm.mib
CPQRPM-MIB DEFINITIONS ::= BEGIN
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
DisplayString ::=
OCTET STRING
PhysAddress ::=
OCTET STRING
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
system OBJECT IDENTIFIER ::= { mib-2 1 }
sysName OBJECT IDENTIFIER ::= { system 5 }
cpqRPM OBJECT IDENTIFIER ::= { compaq 154 }
cpqRPMTrapInfo OBJECT IDENTIFIER ::= { cpqRPM 1 }
cpqRPMTraps OBJECT IDENTIFIER ::= { cpqRPM 2 }
cpqPMTraps OBJECT IDENTIFIER ::= { cpqRPM 3 }
cpqRPMTrapDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Text description of the event that caused the trap."
::= { cpqRPMTrapInfo 1 }
cpqRPMTrapDeviceId OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique numeric identifier for the device that caused the trap."
::= { cpqRPMTrapInfo 2 }
cpqRPMTrapDeviceName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The text name for the device."
::= { cpqRPMTrapInfo 3 }
cpqRPMTrapDeviceAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The hostname or ip address for the device."
::= { cpqRPMTrapInfo 4 }
cpqRPMTrapType OBJECT-TYPE
SYNTAX INTEGER {
system(1),
event(2),
change(3),
power(4),
environment(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the type of the event that caused the trap."
::= { cpqRPMTrapInfo 5 }
cpqRPMTrapSeverity OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
information(2),
normal(3),
minor(4),
major(5),
critical(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the severity of the event that caused the trap."
::= { cpqRPMTrapInfo 6 }
cpqRPMTrapCode OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique identifier for the alarm."
::= { cpqRPMTrapInfo 7 }
cpqRPMTrapURL OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The URL for the management software."
::= { cpqRPMTrapInfo 8 }
cpqRPMTrapUPSInternalFailureCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Internal Failure Cleared (20112)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting an internal failure has been cleared."
::= 20112
cpqRPMTrapCMCSmokeCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Smoke Cleared (10032)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting smoke cleared."
::= 10032
cpqRPMTrapCMCInput1Opened TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Input 1 Opened (10101)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting input 1 has been opened."
::= 10101
cpqRPMTrapCMCLockset1FailedToLock TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Lockset 1 Failed To Lock (10112)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting lockset 1 has failed to lock."
::= 10112
cpqRPMTrapUPSOutputOverloadCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Output Overload Cleared (20015)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting output overload is cleared."
::= 20015
cpqRPMTrapCMCShockCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Shock Cleared (10042)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting shock cleared."
::= 10042
cpqRPMTrapCMCTemp1Normal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Temperature 1 Normal (10004)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting temperature 1 has returned to a normal temperature."
::= 10004
cpqRPMTrapUPSSiteWiringNormal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Site Wiring Fault Cleared (20202)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The input wiring is normal."
::= 20202
cpqRPMTrapUPSTemperatureLow TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Temperature Low (20101)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting temperature blow minimum threshold."
::= 20101
cpqRPMTrapUPSOnUtilityPower TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS On Utility Power (21064)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is supplying output with utility power."
::= 21064
cpqRPMTrapUPSFanFailure TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS has encountered an fan failure. (21035)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a fan failure has occurred. Recommendations: 1If this error persists contact technical support."
::= 21035
cpqRPMTrapUPSBypassManualTurnedOff TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Bypass Manual Turned Off (20192)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The bypass has been given a manual turn off command."
::= 20192
cpqRPMTrapCMCInput1Closed TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Input 1 Closed (10102)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting input 1 has been closed."
::= 10102
cpqRPMTrapUPSShutdownImminentCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS is no longer in an imminent shutdown state. (21014)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a shutdown imminent condition. Recommendations: 1Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!"
::= 21014
cpqRPMTrapDeviceSettingsChanged TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Device Settings Changed (5)"
--#ENABLE true
--#CATEGORY "APPLICATION"
DESCRIPTION "Device settings have been changed by a user."
::= 5
cpqRPMTrapConnectionFailed TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Connection Failed (4)"
--#ENABLE true
--#CATEGORY "APPLICATION"
DESCRIPTION "CRPM failed to connect to a device."
::= 4
cpqRPMTestTrap TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Test Trap (50001)"
--#ENABLE true
--#CATEGORY "APPLICATION"
DESCRIPTION "This trap is sent to test SNMP setup."
::= 50001
cpqRPMTrapCMCShockDetected TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Shock Detected (10041)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting shock detected."
::= 10041
cpqRPMTrapUPSBatteriesDisconnected TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "One or more UPS batteries have been disconnected. (21053)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting batteries are not connected to the UPS. Recomendations: 1Connect the UPS Batteries. The UPS will not be capable of supporting it's load if the utility power fails!"
::= 21053
cpqRPMTrapCMCLockset2Locked TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 2 Locked (10119)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting lockset 2 has been locked."
::= 10119
cpqRPMtrapUPSOutputoutofRange TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Output voltage is out of range (21019)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting output voltage is out of Range. Recommendations: 1Initiate a UPS self test. 2If this error persists contact technical support."
::= 21019
cppqRPMtrapUPSStartedOnBatteryCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Utility power has been restored (20152)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device has been started while on battery power. AC input power is not present. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. If the UPS remains on battery for an extended time it will not be able to sustain the output load!"
::= 20152
cpqRPMTrapConnectionLost TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Connection Lost (2)"
--#ENABLE true
--#CATEGORY "APPLICATION"
DESCRIPTION "CRPM lost the connection to a device."
::= 2
cpqRPMTrapUPSOnBoost TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS On Boost (21031)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is boosting output voltage."
::= 21031
cpqRPMTrapUPSInputUnderOverFreqCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Input Frequency Normal (20142)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "Measured input frequency is normal"
::= 20142
cpqRPMTrapUPSBatteryLowCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Battery Low Cleared (21056)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting low battery. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. 2When utility power is restored, charge the battery to it's full capacity. If the battery level continues to decrease, the UPS will not be able to sustain the output load!"
::= 21056
cpqRPMTrapUPSBatteryFailureCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Battery Failure Cleared (20122)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a battery failure has been cleared."
::= 20122
cpqRPMTrapCMCTemp2AboveMax TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Temperature 2 Above Maximum (10007)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting temperature 2 above maximum threshold."
::= 10007
cpqRPMTrapCMCTemp1AboveWarn TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Temperature 1 Above Warning (10002)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting temperature 1 above warning threshold."
::= 10002
cpqRPMTrapCMCTemp2BelowMin TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Temperature 2 Below Minimum (10005)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting temperature 2 below minimum threshold."
::= 10005
cpqRPMTrapUPSBatteryFailure TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Battery Failure (20121)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a battery failure."
::= 20121
cpqRPMTrapCMCLockset1Error TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 1 Error (10113)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting an error with lockset 1."
::= 10113
cpqRPMTrapUPSDCStartOccurredCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "DC Start Occurred Cleared (29999)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The UPS has been started on utility while AC input power is present."
::= 29999
cpqRPMTrapUPSBatteryLevelNormal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Battery Level Normal (20023)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a normal battery level."
::= 20023
cpqRPMTrapCMCLockset1Unlocked TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 1 Unlocked (10111)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting lockset 1 has been unlocked."
::= 10111
cpqRPMTrapUPSOnBattery TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS On Battery (21063)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is supplying output with its battery."
::= 21063
cpqRPMTrapCMCLockset1Locked TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 1 Locked (10114)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting lockset 1 has been locked."
::= 10114
cpqPMTrapCleared TRAP-TYPE
ENTERPRISE cpqPMTraps
VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Trap code: # $V3V#Description: # $V4V#Name: # $V5V#Url: #"
--#TYPE "Cleared Alarm (4)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "An alarm has cleared. Action: Check the Trap Details for more information."
::= 4
cpqRPMTrapUPSTemperatureHigh TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Temperature High (20102)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting temperature above maximum threshold."
::= 20102
cpqRPMTrapCMCHmdtOver TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Humidity Above Maximum (10022)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting humidity above maximum threshold."
::= 10022
cpqRPMTrapUPSLossOfRedundancy TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS N+1 load has been exceeded (21023)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a loss of redundancy due to one of the following. 1One or more of the Electronics Modules has failed 2One or more of the electronics modules has been manually removed. 3The amount of load on the UPS has increased to the point that the UPS is no longer able to support an N+1 configuration. Recommendations: 1Check the UPS to see if one of the modules has failed. 2Make sure that all modules are securely plugged in. 3Reduce the load to return the N+1 configuration. 4If the amount of load is now going to exceed and N+1 configuration permanently, change the configuration on the front panel of the UPS to Capacity instead of Parallel N+1."
::= 21023
cpqRPMTrapUPSUtilityFailCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Utility Fail Cleared (20172)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "Indicates that the utility input power is within predetermined limits."
::= 20172
cpqRPMtrapUPSBypassONManual TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS is on manual bypass (21059)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is operating in manual bypass mode. Recommendations: 1In bypass mode, the UPS cannot support devices if there is a power failure. 2Once maintenance has been performed return the UPS to normal mode."
::= 21059
cpqRPMTrapUPSOnBuck TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS On Buck (21029)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device reducing output voltage."
::= 21029
cpqRPMtrapUPSInputOutofRangeCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Input voltage is normal (21022)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting input voltage is out of range. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. 2If the UPS remains on battery for an extended period of time it will not be able to sustain the load."
::= 21022
cpqRPMTrapCMCHmdtUnder TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Humidity Below Minimum (10021)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting humidity below minimum threshold."
::= 10021
cpqRPMTrapUPSCheckBreakerCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "All breakers are functioning normally. (21042)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting an output Breaker or Relay has failed or may be stuck open or closed with this alarm. Recommendations: 1Check all breakers on the UPS. 2If this error persists contact technical support."
::= 21042
cpqRPMTrapUPSUtilityNotPresentCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Utility Not Present Cleared (20182)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "Indicates that the utility input is present."
::= 20182
cpqRPMTrapCMCLockset2Error TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 2 Error (10118)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting an error with lockset 2."
::= 10118
cpqRPMTrapUPSShutdownPendingCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS is no longer pending shutdown. (21012)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting shutdown pending condition. Recommendations: 1Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!"
::= 21012
cpqRPMTrapCMCLockset2FailedToLock TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 2 Failed To Lock (10117)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting lockset 2 has failed to lock."
::= 10117
cpqRPMTrapUPSInternalFailure TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Internal Failure (20111)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting an internal failure."
::= 20111
cpqRPMTrapCMCLockset2Normal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 2 Normal (10135)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting lockset 2 is normal."
::= 10135
cpqRPMTrapUPSFanFailureCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS fan failure has cleared. (21036)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a fan failure has occurred. Recommendations: 1If this error persists contact technical support."
::= 21036
cpqRPMTrapLookupFailed TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "DNS Lookup Failed (3)"
--#ENABLE true
--#CATEGORY "APPLICATION"
DESCRIPTION "CRPM failed to find an IP address for the device hostname."
::= 3
cpqRPMTrapUPSEPOInitiated TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Emergency Power Off activated (21037)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting an Emergency Power Off (EPO) command has been received to shutdown the UPS immediately with out delay. This command may come from a local control panel or from a remote source. Recommendations: 1Turn the UPS on to reapply power to attached equipment."
::= 21037
cpqRPMTrapCMCAux2Cleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Aux 2 Alarm Cleared (10054)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting auxiliary input 2 alarm cleared."
::= 10054
cpqRPMTrapCMCHmdtNormal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Humidity Normal (10023)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting humidity has returned to normal."
::= 10023
cpqRPMTrapUPSUtilityFail TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Utility Fail (20171)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "Indicates that the utility input power is not within predetermined limits. This could be, but is not limited to, over voltage, under voltage, over frequency, under frequency or over current."
::= 20171
cpqRPMTrapCMCVoltUnder TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Voltage Below Minimum (10011)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting voltage below minimum threshold."
::= 10011
cpqRPMTrapCMCInput4Closed TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Input 4 Closed (10108)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting input 4 has been closed."
::= 10108
cpqRPMTrapUPSDCStartOccurred TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "DC Start Occurred (29998)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The UPS has been started on battery when AC input power is not present. This alarm is used to record the date and time of this event."
::= 29998
cpqRPMTrapUPSBatteryDischarged TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS batteries are in a discharged condition. (21057)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting batteries are completely discharged. Recommendations: 1Connect the UPS to utility power to charge the batteries. The UPS will not be able to support it's load if the utility power fails!"
::= 21057
cpqRPMTrapUPSBatteryDepleted TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Depleted Battery (20022)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is a depleted battery."
::= 20022
cpqRPMTrapCMCInput4Opened TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Input 4 Opened (10107)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting input 4 has been opened."
::= 10107
cpqRPMTrapUPSCabinetDoorOpenCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "A cover panel has been replaced. (21046)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a cover panel has been removed while utility power is present. Recommendations: 1Reinstall all panels. 2If this error persists contact technical support."
::= 21046
cpqRPMTrapUPSBatteriesDisconnectedCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "All UPS batteries have been reconnected. (21054)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting batteries are not connected to the UPS. Recomendations: 1Connect the UPS Batteries. The UPS will not be capable of supporting it's load if the utility power fails!"
::= 21054
cpqRPMTrapUPSCheckBreaker TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "A UPS circuit breaker needs attention. (21041)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting an output Breaker or Relay has failed or may be stuck open or closed with this alarm. Recommendations: 1Check all breakers on the UPS. 2If this error persists contact technical support."
::= 21041
cpqRPMtrapUPSBypassOnAutoCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS is no longer on auto bypass (21048)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is operating in auto bypass mode. Recommendations: 1In bypass mode, the UPS cannot support devices if there is a power failure. 2Once maintenance has been performed return the UPS to normal mode."
::= 21048
cpqRPMtrapUPSTemperatureOutOfRange TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS temperature out of range (21007)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting temperature is out of range. Recommendations: 1Check to make sure the UPS is in a well ventilated area. 2Lower the ambient temperature in the area where the UPS is located."
::= 21007
cpqRPMTrapUPSBatteryLow TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Battery Low (21055)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a low battery."
::= 21055
cpqRPMTrapUPSTemperatureNormal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Temperature Normal (20103)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting temperature is normal."
::= 20103
cpqRPMTrapCMCAux1Alarm TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Aux 1 Alarm (10051)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device has entered an alarm condition for auxiliary input 1."
::= 10051
cpqRPMTrapUPSShutdownPending TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "A UPS shutdown is pending. (21011)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting shutdown pending condition. Recommendations: 1Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!"
::= 21011
cpqRPMTrapUPSOutputVoltageNormal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Output Voltage Normal (21020)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting output voltage is normal."
::= 21020
cpqRPMTrapCMCLockset1Normal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 2 Normal (10134)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting lockset 2 is normal."
::= 10134
cpqRPMTrapUPSDiagnosticTestFailed TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Diagnostic Test Failed (20131)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a diagnostic test has failed."
::= 20131
cpqRPMTrapCMCVoltNormal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Voltage Normal (10013)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting voltage has returned to normal."
::= 10013
cpqRPMTrapUPSInputVoltageAboveMax TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Input Voltage Above Maximum (20002)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting input voltage above maximum threshold."
::= 20002
cpqRPMTrapUPSInputVoltageBelowMin TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Input Voltage Below Minimum (20001)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting input voltage below minimum threshold."
::= 20001
cpqRPMTrapUPSOnBypass TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS On Bypass (20032)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is being bypassed."
::= 20032
cpqRPMTrapUPSUtilityNotPresent TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Utility Not Present (20181)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "Indicates that the utility input is not present. This differs from alarm #57 in that the detected voltage is zero in this case."
::= 20181
cpqPMTrapWarning TRAP-TYPE
ENTERPRISE cpqPMTraps
VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Trap code: # $V3V#Description: # $V4V#Name: # $V5V#Url: #"
--#TYPE "Warning Alarm (2)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A warning alarm has occurred. Action: Check the Trap Details for more information."
::= 2
cpqRPMTrapCMCLockset2Unlocked TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Lockset 2 Unlocked (10116)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting lockset 2 has been unlocked."
::= 10116
cpqRPMTrapUPSShutdownImminent TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "A UPS shutdown is imminent. (21013)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a shutdown imminent condition. Recommendations: 1Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!"
::= 21013
cpqRPMTrapCMCVoltOver TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Voltage Above Maximum (10012)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting voltage above maximum threshold."
::= 10012
cpqRPMTrapUPSInputUnderOverFreq TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Input Under Or Over Frequency (20141)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "Input (Utility) fault: measured input frequency is outside of either the upper or lower frequency limit specification for normal operation."
::= 20141
cpqRPMTrapUPSLossOfRedundancyCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Loss of redundancy cleared or configuration has changed from N+1 to Capacity (21024)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a loss of redundancy due to one of the following. 1One or more of the Electronics Modules has failed 2One or more of the electronics modules has been manually removed. 3The amount of load on the UPS has increased to the point that the UPS is no longer able to support an N+1 configuration. Recommendations: 1Check the UPS to see if one of the modules has failed. 2Make sure that all modules are securely plugged in. 3Reduce the load to return the N+1 configuration. 4If the amount of load is now going to exceed and N+1 configuration permanently, change the configuration on the front panel of the UPS to Capacity instead of Parallel N+1."
::= 21024
cpqRPMTrapUPSSiteWiringFault TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Site Wiring Fault (20201)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "There is a fault in the input wiring."
::= 20201
cpqRPMTrapUPSOutputVoltageAboveMax TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Output Voltage Above Maximum (20012)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting output voltage above maximum threshold."
::= 20012
cpqRPMTrapUPSBypassManualTurnedOn TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Bypass Manual Turned On (20191)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The bypass has been given a manual turn on command."
::= 20191
cppqRPMtrapUPSStartedOnBattery TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS was started without utility power (20151)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device has been started while on battery power. AC input power is not present. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. If the UPS remains on battery for an extended time it will not be able to sustain the output load."
::= 20151
cpqRPMTrapCMCAux2Alarm TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Aux 2 Alarm (10053)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device has entered an alarm condition for auxiliary input 2."
::= 10053
cpqRPMTrapUPSInputVoltageNormal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Input Voltage Normal (20003)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting input voltage is normal."
::= 20003
cpqRPMTrapUPSOutputVoltageBelowMin TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Output Voltage Below Minimum (20011)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting output voltage below minimum threshold."
::= 20011
cpqRPMTrapCMCInput3Closed TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Input 3 Closed (10106)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting input 3 has been closed."
::= 10106
cpqRPMTrapCMCTemp1AboveMax TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Temperature 1 Above Maximum (10003)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting temperature 1 above maximum threshold."
::= 10003
cpqRPMTrapUPSCabinetDoorOpen TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "A cover panel has been removed. (21045)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a cover panel has been removed while utility power is present. Recommendations: 1Reinstall all panels. 2If this error persists contact technical support."
::= 21045
cpqRPMTrapCMCInput3Opened TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Input 3 Opened (10105)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting input 3 has been opened."
::= 10105
cpqPMTrapInformation TRAP-TYPE
ENTERPRISE cpqPMTraps
VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Trap code: # $V3V#Description: # $V4V#Name: # $V5V#Url: #"
--#TYPE "Information Alarm (3)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "An information alarm has occurred. Action: Check the Trap Details for more information."
::= 3
cpqRPMTrapCMCTemp2AboveWarn TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Temperature 2 Above Warning (10006)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting temperature 2 above warning threshold."
::= 10006
cpqRPMTrapCMCTemp1BelowMin TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Temperature 1 Below Minimum (10001)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting temperature 1 below minimum threshold."
::= 10001
cpqRPMTrapUPSBypassNotAvailable TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Bypass Not Available (20161)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The bypass input voltage is not available for transfer to. This may be due to any reason. Some of which are: over/under voltage, over/under frequency, out of phase lock."
::= 20161
cpqRPMTrapUPSOutputOverload TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Output Overload (20014)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting output is overloaded."
::= 20014
cpqRPMTrapUPSBatteryDischargedCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS batteries are in a discharged condition. (21058)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting batteries are completely discharged. Recommendations: 1Connect the UPS to utility power to charge the batteries. The UPS will not be able to support it's load if the utility power fails!"
::= 21058
cpqRPMtrapUPSTemperatureOutOfRangeCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS temperature has returned to normal (21008)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting temperature is out of range. Recommendations: 1Check to make sure the UPS is in a well ventilated area. 2Lower the ambient temperature in the area where the UPS is located."
::= 21008
cpqRPMTrapCMCSmokeDetected TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Smoke Detected (10031)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting smoke detected."
::= 10031
cpqRPMTrapCMCInput2Closed TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Input 2 Closed (10104)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting input 2 has been closed."
::= 10104
cpqRPMTrapUPSManualLoadDumped TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS output has been manually turned off. (21033)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The UPS has been powered off with user interaction."
::= 21033
cpqRPMTrapUPSDiagnosticTestSucceeded TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS Diagnostic Test Succeeded (20132)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting a diagnostic test has succeeded."
::= 20132
cpqPMTrapCritical TRAP-TYPE
ENTERPRISE cpqPMTraps
VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL }
--#SEVERITY CRITICAL
--#MSG_FORMATTER "$V2V#Trap code: # $V3V#Description: # $V4V#Name: # $V5V#Url: #"
--#TYPE "Critical Alarm (1)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A critical alarm has occurred. Action: Check the Trap Details for more information."
::= 1
cpqRPMTrapCMCInput2Opened TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MINOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Input 2 Opened (10103)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting input 2 has been opened."
::= 10103
cpqRPMtrapUPSBypassOnAuto TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS is on automatic bypass (21047)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is operating in auto bypass mode. Recommendations: 1In bypass mode, the UPS cannot support devices if there is a power failure. 2Once maintenance has been performed return the UPS to normal mode."
::= 21047
cpqRPMTrapCMCAux1Cleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Aux 1 Alarm Cleared (10052)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting auxiliary input 1 alarm cleared."
::= 10052
cpqRPMtrapUPSBypassOffManual TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "The UPS is no longer on manual bypass (21060)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is operating in manual bypass mode. Recommendations: 1In bypass mode, the UPS cannot support devices if there is a power failure. 2Once maintenance has been performed return the UPS to normal mode."
::= 21060
cpqRPMTrapUPSManualLoadDumpedCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "UPS output has been restored (21034)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The UPS has been powered off with user interaction."
::= 21034
cpqRPMtrapUPSInputOutofRange TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY MAJOR
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Input voltage is out of range (21021)"
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "A UPS device is reporting input voltage is out of range. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. 2If the UPS remains on battery for an extended period of time it will not be able to sustain the load."
::= 21021
cpqRPMTrapCMCTemp2Normal TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "CMC Temperature 2 Normal (10008)"
--#ENABLE true
--#CATEGORY "SYSTEM AND ENVIRONMENTAL"
DESCRIPTION "A CMC device is reporting temperature 2 has returned to a normal temperature."
::= 10008
cpqRPMTrapUPSBypassNotAvailableCleared TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Bypass Not Available Cleared (20162)"
--#ENABLE true
--#CATEGORY "Proliant UPS Events"
DESCRIPTION "The bypass input voltage is available for transfer to."
::= 20162
cpqRPMTrapDeviceConnected TRAP-TYPE
ENTERPRISE cpqRPMTraps
VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL }
--#SEVERITY INFORMATIONAL
--#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #"
--#TYPE "Device Connected (1)"
--#ENABLE true
--#CATEGORY "APPLICATION"
DESCRIPTION "CRPM successfully connected to a device."
::= 1
END