#-MIBFILE: cpqrack.mib
CPQRACK-MIB DEFINITIONS ::= BEGIN
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
DisplayString ::=
OCTET STRING
PhysAddress ::=
OCTET STRING
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
system OBJECT IDENTIFIER ::= { mib-2 1 }
sysName OBJECT IDENTIFIER ::= { system 5 }
cpqHostOs OBJECT IDENTIFIER ::= { compaq 11 }
cpqHoComponent OBJECT IDENTIFIER ::= { cpqHostOs 2 }
cpqHoTrapInfo OBJECT IDENTIFIER ::= { cpqHoComponent 11 }
cpqHoTrapFlags OBJECT IDENTIFIER ::= { cpqHoTrapInfo 1 }
cpqRackInfo OBJECT IDENTIFIER ::= { compaq 22 }
cpqRackMibRev OBJECT IDENTIFIER ::= { cpqRackInfo 1 }
cpqRackComponent OBJECT IDENTIFIER ::= { cpqRackInfo 2 }
cpqRackSysObjID OBJECT IDENTIFIER ::= { cpqRackInfo 3 }
cpqRackInterface OBJECT IDENTIFIER ::= { cpqRackComponent 1 }
cpqRackAsset OBJECT IDENTIFIER ::= { cpqRackComponent 2 }
cpqRackEnclosure OBJECT IDENTIFIER ::= { cpqRackComponent 3 }
cpqRackServer OBJECT IDENTIFIER ::= { cpqRackComponent 4 }
cpqRackPower OBJECT IDENTIFIER ::= { cpqRackComponent 5 }
cpqRackNetwork OBJECT IDENTIFIER ::= { cpqRackComponent 6 }
cpqRackOsCommon OBJECT IDENTIFIER ::= { cpqRackInterface 4 }
cpqRackCommonEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 1 }
cpqRackServerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 2 }
cpqRackPowerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 3 }
cpqRackServerBlade OBJECT IDENTIFIER ::= { cpqRackServer 1 }
cpqRackServerNetworking OBJECT IDENTIFIER ::= { cpqRackServer 2 }
cpqRackServerTempSensor OBJECT IDENTIFIER ::= { cpqRackServer 3 }
cpqRackPowerSupply OBJECT IDENTIFIER ::= { cpqRackPower 1 }
cpqRackNetConnector OBJECT IDENTIFIER ::= { cpqRackNetwork 1 }
cpqRackMibRevMajor OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The major revision level of the MIB.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level."
::= { cpqRackMibRev 1 }
cpqRackMibRevMinor OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The minor revision level of the MIB.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred."
::= { cpqRackMibRev 2 }
cpqRackMibCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The overall condition.
This object represents the overall status of the
rack information represented by this MIB."
::= { cpqRackMibRev 3 }
cpqRackOsCommonPollFreq OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Management Agent's polling frequency.
The frequency, in seconds, at which the Agent requests
information from the device driver. A frequency of zero (0)
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero (0) will
always fail, an agent may also choose to fail any request to
change the poll frequency to a value that would severely impact
system performance."
::= { cpqRackOsCommon 1 }
cpqRackAssetTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackAssetEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack asset information."
::= { cpqRackAsset 1 }
cpqRackAssetEntry OBJECT-TYPE
SYNTAX CpqRackAssetEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack asset description."
INDEX { cpqRackAssetIndex }
::= { cpqRackAssetTable 1 }
cpqRackAssetEntry ::=
SEQUENCE {
cpqRackAssetIndex INTEGER,
cpqRackName DisplayString,
cpqRackUid DisplayString,
cpqRackSerialNum DisplayString,
cpqRackTrapSequenceNum INTEGER,
cpqRackHeight INTEGER,
cpqRackWidth INTEGER,
cpqRackDepth INTEGER
}
cpqRackAssetIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack table entry."
::= { cpqRackAssetEntry 1 }
cpqRackName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The customer changeable identifier used to identify the entire
rack.
The string will be empty if the system does not report this
function."
::= { cpqRackAssetEntry 2 }
cpqRackUid OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The rack unique identifier.
The string will be empty if the rack does not report the
UID or if it could not be determined."
::= { cpqRackAssetEntry 3 }
cpqRackSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The rack serial number.
The string will be empty if the rack does not report the
serial number."
::= { cpqRackAssetEntry 4 }
cpqRackTrapSequenceNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The trap sequence number for rack traps.
This is used by the management application trap processing.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackAssetEntry 5 }
cpqRackHeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The internal height dimension of the useable rack space expressed
in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackAssetEntry 6 }
cpqRackWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The internal width dimension of the useable rack space expressed
in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackAssetEntry 7 }
cpqRackDepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The internal depth dimension of the useable rack space expressed
in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackAssetEntry 8 }
cpqRackCommonEnclosureTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackCommonEnclosureEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack enclosure information."
::= { cpqRackCommonEnclosure 1 }
cpqRackCommonEnclosureEntry OBJECT-TYPE
SYNTAX CpqRackCommonEnclosureEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack enclosure description."
INDEX { cpqRackCommonEnclosureRack , cpqRackCommonEnclosureIndex }
::= { cpqRackCommonEnclosureTable 1 }
cpqRackCommonEnclosureEntry ::=
SEQUENCE {
cpqRackCommonEnclosureRack INTEGER,
cpqRackCommonEnclosureIndex INTEGER,
cpqRackCommonEnclosureModel DisplayString,
cpqRackCommonEnclosureAssetTag DisplayString,
cpqRackCommonEnclosurePartNumber DisplayString,
cpqRackCommonEnclosureSparePartNumber DisplayString,
cpqRackCommonEnclosureSerialNum DisplayString,
cpqRackCommonEnclosureFWRev DisplayString,
cpqRackCommonEnclosureName DisplayString,
cpqRackCommonEnclosureNeighborNamePrev DisplayString,
cpqRackCommonEnclosureNeighborNameNext DisplayString,
cpqRackCommonEnclosureHeight INTEGER,
cpqRackCommonEnclosureWidth INTEGER,
cpqRackCommonEnclosureDepth INTEGER,
cpqRackCommonEnclosureTrapSequenceNum INTEGER,
cpqRackCommonEnclosureCondition INTEGER,
cpqRackCommonEnclosureHasServerBlades INTEGER,
cpqRackCommonEnclosureHasPowerSupplies INTEGER,
cpqRackCommonEnclosureHasNetConnectors INTEGER,
cpqRackCommonEnclosureHasTempSensors INTEGER,
cpqRackCommonEnclosureHasFans INTEGER,
cpqRackCommonEnclosureHasFuses INTEGER,
cpqRackCommonEnclosureMgmtUID INTEGER,
cpqRackCommonEnclosureSerialNumPrev DisplayString,
cpqRackCommonEnclosureSerialNumNext DisplayString,
cpqRackCommonEnclosureAddress INTEGER,
cpqRackCommonEnclosureProductId DisplayString,
cpqRackCommonEnclosureProductIdPrev DisplayString,
cpqRackCommonEnclosureProductIdNext DisplayString,
cpqRackCommonEnclosureUUID DisplayString,
cpqRackCommonEnclosureUUIDPrev DisplayString,
cpqRackCommonEnclosureUUIDNext DisplayString,
cpqRackCommonEnclosureHasManagers INTEGER
}
cpqRackCommonEnclosureRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackCommonEnclosureEntry 1 }
cpqRackCommonEnclosureIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackCommonEnclosureEntry 2 }
cpqRackCommonEnclosureModel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The model name of the enclosure.
The string will be empty if the enclosure does not report the
model information."
::= { cpqRackCommonEnclosureEntry 3 }
cpqRackCommonEnclosureAssetTag OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The customer changeable asset identifier of the enclosure.
The string will be empty if the system does not report this
function or if the asset tag has not been set."
::= { cpqRackCommonEnclosureEntry 4 }
cpqRackCommonEnclosurePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The part number of the enclosure.
The string will be empty if the enclosure does not report this
function."
::= { cpqRackCommonEnclosureEntry 5 }
cpqRackCommonEnclosureSparePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The spare part number of the enclosure.
The string will be empty if the enclosure does not report this
function."
::= { cpqRackCommonEnclosureEntry 6 }
cpqRackCommonEnclosureSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure.
The string will be empty if the enclosure does not report the
serial number."
::= { cpqRackCommonEnclosureEntry 7 }
cpqRackCommonEnclosureFWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The firmware revision of the enclosure.
The string will be empty if the enclosure does not report the
firmware revision or does not contain firmware."
::= { cpqRackCommonEnclosureEntry 8 }
cpqRackCommonEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackCommonEnclosureEntry 9 }
cpqRackCommonEnclosureNeighborNamePrev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure immediately preceding or above this
enclosure.
The string will be empty if the neighbor enclosure name could not be
determined or there is no enclosure preceding this one."
::= { cpqRackCommonEnclosureEntry 10 }
cpqRackCommonEnclosureNeighborNameNext OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure immediately following or below this
enclosure.
The string will be empty if the neighbor enclosure name could not be
determined or there is no enclosure following this one."
::= { cpqRackCommonEnclosureEntry 11 }
cpqRackCommonEnclosureHeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The height dimension of the rack space taken by the
enclosure expressed in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackCommonEnclosureEntry 12 }
cpqRackCommonEnclosureWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The width dimension of the rack space taken by the
enclosure expressed in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackCommonEnclosureEntry 13 }
cpqRackCommonEnclosureDepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The depth dimension of the rack space taken by the
enclosure expressed in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackCommonEnclosureEntry 14 }
cpqRackCommonEnclosureTrapSequenceNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The trap sequence number for the enclosure.
This is used by the management application trap processing.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackCommonEnclosureEntry 15 }
cpqRackCommonEnclosureCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The overall condition of the enclosure.
This is the aggregate of the temperature sensors, fans, and
fuses within the enclosure.
This value will be one of the following:
other(1)
No temperature sensors, fans, or fuses in the enclosure or the
state could no be determined.
ok(2)
All temperature sensors, fans, and fuses are within the normal
operating range.
degraded(3)
One or more temperature sensors, fans, or fuses are outside of
the normal operating range. None are failed.
failed(4)
The temperature sensor exceeded the critical threshold value,
a required fan has failed, or a fuse has been tripped.
The system will automatically shutdown if the failed(4) condition
results, so it is unlikely that this value will ever be returned
by the agent."
::= { cpqRackCommonEnclosureEntry 16 }
cpqRackCommonEnclosureHasServerBlades OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The enclosure can contain server blades.
This will be true(2) is the enclosure can house server blades. The
cpqRackServerEnclosureTable will contain server enclosure specific
information.
Match the cpqRackCommonEnclosureSerialNum in this table to the
serial number in the cpqRackServerEnclosureTable to get complete
information on the server enclosure."
::= { cpqRackCommonEnclosureEntry 17 }
cpqRackCommonEnclosureHasPowerSupplies OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The enclosure can contain power supplies.
This will be true(2) is the enclosure can house power supplies. The
cpqRackEnclosurePowerTable will contain power enclosure specific
information.
Match the cpqRackCommonEnclosureSerialNum in this table to the
serial number in the cpqRackEnclosurePowerTable to get complete
information on the power enclosure."
::= { cpqRackCommonEnclosureEntry 18 }
cpqRackCommonEnclosureHasNetConnectors OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The enclosure contains network connectivity.
This will be true(2) is the enclosure contains network connectivity.
The cpqRackCommonEnclosureNetConnectorTable will contain network
connectivity specific information.
Match the cpqRackCommonEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureNetConnectorTable to get complete
information on the network connector enclosure."
::= { cpqRackCommonEnclosureEntry 19 }
cpqRackCommonEnclosureHasTempSensors OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The enclosure contains temperature sensors.
This will be true(2) is the enclosure contains
temperature sensors. The cpqRackCommonEnclosureTempTable will
contain temperature sensor specific information.
Match the cpqRackCommonEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureTempTable to get complete
information on the enclosure."
::= { cpqRackCommonEnclosureEntry 20 }
cpqRackCommonEnclosureHasFans OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The enclosure contains fans.
This will be true(2) is the enclosure contains fans.
The cpqRackCommonEnclosureFanTable will contain the fan
specific information.
Match the cpqRackCommonEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureFanTable to get complete
information on the enclosure."
::= { cpqRackCommonEnclosureEntry 21 }
cpqRackCommonEnclosureHasFuses OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The enclosure contains fuses.
This will be true(2) is the enclosure contains fuses.
The cpqRackCommonEnclosureFuseTable will contain the fuse
specific information.
Match the cpqRackCommonEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureFuseTable to get complete
information on the enclosure."
::= { cpqRackCommonEnclosureEntry 22 }
cpqRackCommonEnclosureMgmtUID OBJECT-TYPE
SYNTAX INTEGER {
other(1),
none(2),
ledOn(3),
ledOff(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Unit Identifier LED.
This value will be one of the following:
other(1)
The state of the LED could not be determined. Setting the
LED state is not allowed.
none(2)
The LED is not present. Setting LED state is not allowed.
ledOn(3)
The LED is present and ON. The LED can be turned off
by setting the cpqRackCommonEnclosureMgmtUID to ledOff(4).
ledOff(4)
The LED is present and OFF. The LED can be turned on
by setting the cpqRackCommonEnclosureMgmtUID to ledOn(3)."
::= { cpqRackCommonEnclosureEntry 23 }
cpqRackCommonEnclosureSerialNumPrev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure immediately preceding or
above this enclosure.
The string will be empty if the neighbor enclosure serial number
could not be determined or there is no enclosure preceding this one."
::= { cpqRackCommonEnclosureEntry 24 }
cpqRackCommonEnclosureSerialNumNext OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure immediately following or
below this enclosure.
The string will be empty if the neighbor enclosure serial number
could not be determined or there is no enclosure following this one."
::= { cpqRackCommonEnclosureEntry 25 }
cpqRackCommonEnclosureAddress OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The unique address of the enclosure within the rack.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackCommonEnclosureEntry 26 }
cpqRackCommonEnclosureProductId OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The product id string of the enclosure.
The string will be empty if the enclosure does not report the
product id string."
::= { cpqRackCommonEnclosureEntry 27 }
cpqRackCommonEnclosureProductIdPrev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The product id string of the enclosure immediately preceding or
above this enclosure.
The string will be empty if the enclosure does not report the
product id string."
::= { cpqRackCommonEnclosureEntry 28 }
cpqRackCommonEnclosureProductIdNext OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The product id string of the enclosure immediately following or
below this enclosure.
The string will be empty if the enclosure does not report the
product id string."
::= { cpqRackCommonEnclosureEntry 29 }
cpqRackCommonEnclosureUUID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The universal unique identifier string of the enclosure.
The string will be empty if the enclosure does not report the
UUID string."
::= { cpqRackCommonEnclosureEntry 30 }
cpqRackCommonEnclosureUUIDPrev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The universal unique identifier string of the enclosure
immediately preceding or above this enclosure.
The string will be empty if the enclosure does not report the
UUID string or if there is no preceding enclosure."
::= { cpqRackCommonEnclosureEntry 31 }
cpqRackCommonEnclosureUUIDNext OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The universal unique identifier string of the enclosure
immediately following or below this enclosure.
The string will be empty if the enclosure does not report the
UUID string or if there is no following enclosure."
::= { cpqRackCommonEnclosureEntry 32 }
cpqRackCommonEnclosureHasManagers OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The enclosure contains managers.
This will be true(2) is the enclosure contains managers.
The cpqRackCommonEnclosureManagerTable will contain the manager
specific information.
Match the cpqRackCommonEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureManagerTable to get
complete information on the enclosure."
::= { cpqRackCommonEnclosureEntry 33 }
cpqRackCommonEnclosureTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackCommonEnclosureTempEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack enclosure temperature sensor information."
::= { cpqRackCommonEnclosure 2 }
cpqRackCommonEnclosureTempEntry OBJECT-TYPE
SYNTAX CpqRackCommonEnclosureTempEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack enclosure temperature sensor description."
INDEX { cpqRackCommonEnclosureTempRack , cpqRackCommonEnclosureTempChassis, cpqRackCommonEnclosureTempSensorIndex }
::= { cpqRackCommonEnclosureTempTable 1 }
cpqRackCommonEnclosureTempEntry ::=
SEQUENCE {
cpqRackCommonEnclosureTempRack INTEGER,
cpqRackCommonEnclosureTempChassis INTEGER,
cpqRackCommonEnclosureTempSensorIndex INTEGER,
cpqRackCommonEnclosureTempSensorEnclosureName DisplayString,
cpqRackCommonEnclosureTempLocation DisplayString,
cpqRackCommonEnclosureTempCurrent INTEGER,
cpqRackCommonEnclosureTempThreshold INTEGER,
cpqRackCommonEnclosureTempCondition INTEGER,
cpqRackCommonEnclosureTempType INTEGER,
cpqRackCommonEnclosureTempSensorEnclosureSerialNum DisplayString
}
cpqRackCommonEnclosureTempRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackCommonEnclosureTempEntry 1 }
cpqRackCommonEnclosureTempChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackCommonEnclosureTempEntry 2 }
cpqRackCommonEnclosureTempSensorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this temperature sensor within
this enclosure in the rack."
::= { cpqRackCommonEnclosureTempEntry 3 }
cpqRackCommonEnclosureTempSensorEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackCommonEnclosureTempEntry 4 }
cpqRackCommonEnclosureTempLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The location description of the temperature sensor within the
enclosure.
The string will be empty if the location could not be
determined."
::= { cpqRackCommonEnclosureTempEntry 5 }
cpqRackCommonEnclosureTempCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is the current temperature sensor reading in degrees
celsius.
If this value cannot be determined by software, then a value
of -1 will be returned."
::= { cpqRackCommonEnclosureTempEntry 6 }
cpqRackCommonEnclosureTempThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is the threshold temperature sensor setting
in degrees celsius. This is the temperature in which the
sensor will be considered to be in a tripped state this
causing some action to occur depending on the type of
the sensor. The action of temperature sensor threshold
will be indicated by the cpqRackCommonEnclosureTempType
item. If the type is blowout(5), then the temperature sensor
will cause the fans to speed up. If the type is caution(9),
then the temperature sensor is in a degraded state. If the
type is critical(15), then the enclosure will be considered
as in a failed state.
If this value cannot be determined by software, then a value
of -1 will be returned."
::= { cpqRackCommonEnclosureTempEntry 7 }
cpqRackCommonEnclosureTempCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within the normal operating range.
degraded(3)
The temperature sensor is outside of the normal operating range.
failed(4)
The temperature sensor detects a condition that could
possibly damage the system.
The system will automatically shutdown if the failed(4) condition
results, so it is unlikely that this value will ever be returned
by the agent."
::= { cpqRackCommonEnclosureTempEntry 8 }
cpqRackCommonEnclosureTempType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
blowout(5),
caution(9),
critical(15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies the type of this instance of temperature
sensor.
This value will be one of the following:
other(1)
Temperature threshold type could not be determined.
blowout(5)
If a blowout(5) temperature sensor reaches its threshold,
the fan or fans in the area of the temperature sensor will
increase in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.
caution(9)
If a caution(9) temperature sensor reaches its threshold, the
cpqRackCommonEnclosureTempCondition will be set to degraded(3)
and the system will either continue or shutdown depending
on the user preferences.
critical(15)
If a critical(15) temperature sensor reaches its threshold,
the cpqHeTemperatureCondition will be set to failed(4)
and the system will shutdown."
::= { cpqRackCommonEnclosureTempEntry 9 }
cpqRackCommonEnclosureTempSensorEnclosureSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure containing this temperature
sensor.
The string will be empty if the enclosure does not report the
serial number or it could not be determined."
::= { cpqRackCommonEnclosureTempEntry 10 }
cpqRackCommonEnclosureFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFanEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack enclosure fan information."
::= { cpqRackCommonEnclosure 3 }
cpqRackCommonEnclosureFanEntry OBJECT-TYPE
SYNTAX CpqRackCommonEnclosureFanEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack enclosure fan description."
INDEX { cpqRackCommonEnclosureFanRack , cpqRackCommonEnclosureFanChassis, cpqRackCommonEnclosureFanIndex }
::= { cpqRackCommonEnclosureFanTable 1 }
cpqRackCommonEnclosureFanEntry ::=
SEQUENCE {
cpqRackCommonEnclosureFanRack INTEGER,
cpqRackCommonEnclosureFanChassis INTEGER,
cpqRackCommonEnclosureFanIndex INTEGER,
cpqRackCommonEnclosureFanEnclosureName DisplayString,
cpqRackCommonEnclosureFanLocation DisplayString,
cpqRackCommonEnclosureFanPartNumber DisplayString,
cpqRackCommonEnclosureFanSparePartNumber DisplayString,
cpqRackCommonEnclosureFanPresent INTEGER,
cpqRackCommonEnclosureFanRedundant INTEGER,
cpqRackCommonEnclosureFanRedundantGroupId INTEGER,
cpqRackCommonEnclosureFanCondition INTEGER,
cpqRackCommonEnclosureFanEnclosureSerialNum DisplayString
}
cpqRackCommonEnclosureFanRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackCommonEnclosureFanEntry 1 }
cpqRackCommonEnclosureFanChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackCommonEnclosureFanEntry 2 }
cpqRackCommonEnclosureFanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this fan within this
enclosure in the rack."
::= { cpqRackCommonEnclosureFanEntry 3 }
cpqRackCommonEnclosureFanEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackCommonEnclosureFanEntry 4 }
cpqRackCommonEnclosureFanLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The location description of the fan within the enclosure.
The string will be empty if the location could not be
determined."
::= { cpqRackCommonEnclosureFanEntry 5 }
cpqRackCommonEnclosureFanPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The part number of the enclosure fan.
The string will be empty if the part number could not be
determined."
::= { cpqRackCommonEnclosureFanEntry 6 }
cpqRackCommonEnclosureFanSparePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The spare part number of the enclosure fan.
The string will be empty if the part number could not be
determined."
::= { cpqRackCommonEnclosureFanEntry 7 }
cpqRackCommonEnclosureFanPresent OBJECT-TYPE
SYNTAX INTEGER {
other(1),
absent(2),
present(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies if the fan described is present in the system."
::= { cpqRackCommonEnclosureFanEntry 8 }
cpqRackCommonEnclosureFanRedundant OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notRedundant(2),
redundant(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies if the fan is in a redundant configuration."
::= { cpqRackCommonEnclosureFanEntry 9 }
cpqRackCommonEnclosureFanRedundantGroupId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies the group number for redundant fans within this
enclosure."
::= { cpqRackCommonEnclosureFanEntry 10 }
cpqRackCommonEnclosureFanCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The condition of the fan.
This value will be one of the following:
other(1)
Fan status detection is not supported.
ok(2)
The fan is operating properly.
degraded(2)
A redundant fan is not operating properly.
failed(4)
A non-redundant fan is not operating properly."
::= { cpqRackCommonEnclosureFanEntry 11 }
cpqRackCommonEnclosureFanEnclosureSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure containing the fan.
The string will be empty if the enclosure does not report the
serial number or it could not be determined."
::= { cpqRackCommonEnclosureFanEntry 12 }
cpqRackCommonEnclosureFuseTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFuseEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack enclosure fuse information."
::= { cpqRackCommonEnclosure 4 }
cpqRackCommonEnclosureFuseEntry OBJECT-TYPE
SYNTAX CpqRackCommonEnclosureFuseEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack enclosure fuse description."
INDEX { cpqRackCommonEnclosureFuseRack , cpqRackCommonEnclosureFuseChassis, cpqRackCommonEnclosureFuseIndex }
::= { cpqRackCommonEnclosureFuseTable 1 }
cpqRackCommonEnclosureFuseEntry ::=
SEQUENCE {
cpqRackCommonEnclosureFuseRack INTEGER,
cpqRackCommonEnclosureFuseChassis INTEGER,
cpqRackCommonEnclosureFuseIndex INTEGER,
cpqRackCommonEnclosureFuseEnclosureName DisplayString,
cpqRackCommonEnclosureFuseLocation DisplayString,
cpqRackCommonEnclosureFusePresent INTEGER,
cpqRackCommonEnclosureFuseCondition INTEGER
}
cpqRackCommonEnclosureFuseRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackCommonEnclosureFuseEntry 1 }
cpqRackCommonEnclosureFuseChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackCommonEnclosureFuseEntry 2 }
cpqRackCommonEnclosureFuseIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies the fuse within this enclosure."
::= { cpqRackCommonEnclosureFuseEntry 3 }
cpqRackCommonEnclosureFuseEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackCommonEnclosureFuseEntry 4 }
cpqRackCommonEnclosureFuseLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The location description of the fuse within the enclosure.
The string will be empty if the location could not be
determined."
::= { cpqRackCommonEnclosureFuseEntry 5 }
cpqRackCommonEnclosureFusePresent OBJECT-TYPE
SYNTAX INTEGER {
other(1),
absent(2),
present(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies if the fuse described is present in the system."
::= { cpqRackCommonEnclosureFuseEntry 6 }
cpqRackCommonEnclosureFuseCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The condition of the fuse.
This value will be one of the following:
other(1)
Fuse status detection is not supported.
ok(2)
The fuse is operating properly.
failed(4)
A fuse has been tripped or is not operating properly."
::= { cpqRackCommonEnclosureFuseEntry 7 }
cpqRackCommonEnclosureFruTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFruEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack enclosure field replaceable units information."
::= { cpqRackCommonEnclosure 5 }
cpqRackCommonEnclosureFruEntry OBJECT-TYPE
SYNTAX CpqRackCommonEnclosureFruEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack enclosure field replaceable unit description."
INDEX { cpqRackCommonEnclosureFruRack , cpqRackCommonEnclosureFruChassis, cpqRackCommonEnclosureFruIndex }
::= { cpqRackCommonEnclosureFruTable 1 }
cpqRackCommonEnclosureFruEntry ::=
SEQUENCE {
cpqRackCommonEnclosureFruRack INTEGER,
cpqRackCommonEnclosureFruChassis INTEGER,
cpqRackCommonEnclosureFruIndex INTEGER,
cpqRackCommonEnclosureFruEnclosureName DisplayString,
cpqRackCommonEnclosureFruDescription DisplayString,
cpqRackCommonEnclosureFruLocation DisplayString,
cpqRackCommonEnclosureFruAssemblyPartNumber DisplayString,
cpqRackCommonEnclosureFruSparePartNumber DisplayString,
cpqRackCommonEnclosureFruAutoRev DisplayString,
cpqRackCommonEnclosureFruSerialNum DisplayString
}
cpqRackCommonEnclosureFruRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackCommonEnclosureFruEntry 1 }
cpqRackCommonEnclosureFruChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackCommonEnclosureFruEntry 2 }
cpqRackCommonEnclosureFruIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies the FRU within this enclosure."
::= { cpqRackCommonEnclosureFruEntry 3 }
cpqRackCommonEnclosureFruEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackCommonEnclosureFruEntry 4 }
cpqRackCommonEnclosureFruDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the FRU component.
The string will be empty if the enclosure does not report the
description information."
::= { cpqRackCommonEnclosureFruEntry 5 }
cpqRackCommonEnclosureFruLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The location description of the FRU within the enclosure.
The string will be empty if the location could not be
determined."
::= { cpqRackCommonEnclosureFruEntry 6 }
cpqRackCommonEnclosureFruAssemblyPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The assembly part number of the FRU within the enclosure.
The string will be empty if the enclosure does not report this
information."
::= { cpqRackCommonEnclosureFruEntry 7 }
cpqRackCommonEnclosureFruSparePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The spare part number of the FRU within the enclosure.
The string will be empty if the enclosure does not report this
information."
::= { cpqRackCommonEnclosureFruEntry 8 }
cpqRackCommonEnclosureFruAutoRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The auto revision number of the FRU within the enclosure.
The string will be empty if the enclosure does not report this
information."
::= { cpqRackCommonEnclosureFruEntry 9 }
cpqRackCommonEnclosureFruSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the FRU within the enclosure.
The string will be empty if the enclosure does not report the
serial number."
::= { cpqRackCommonEnclosureFruEntry 10 }
cpqRackCommonEnclosureManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackCommonEnclosureManagerEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack enclosure manager information."
::= { cpqRackCommonEnclosure 6 }
cpqRackCommonEnclosureManagerEntry OBJECT-TYPE
SYNTAX CpqRackCommonEnclosureManagerEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack enclosure manager description."
INDEX { cpqRackCommonEnclosureManagerRack , cpqRackCommonEnclosureManagerChassis, cpqRackCommonEnclosureManagerIndex }
::= { cpqRackCommonEnclosureManagerTable 1 }
cpqRackCommonEnclosureManagerEntry ::=
SEQUENCE {
cpqRackCommonEnclosureManagerRack INTEGER,
cpqRackCommonEnclosureManagerChassis INTEGER,
cpqRackCommonEnclosureManagerIndex INTEGER,
cpqRackCommonEnclosureManagerEnclosureName DisplayString,
cpqRackCommonEnclosureManagerLocation DisplayString,
cpqRackCommonEnclosureManagerPartNumber DisplayString,
cpqRackCommonEnclosureManagerSparePartNumber DisplayString,
cpqRackCommonEnclosureManagerSerialNum DisplayString,
cpqRackCommonEnclosureManagerRole INTEGER,
cpqRackCommonEnclosureManagerPresent INTEGER,
cpqRackCommonEnclosureManagerRedundant INTEGER,
cpqRackCommonEnclosureManagerCondition INTEGER,
cpqRackCommonEnclosureManagerEnclosureSerialNum DisplayString,
cpqRackCommonEnclosureManagerUUID DisplayString,
cpqRackCommonEnclosureManagerFWRev DisplayString
}
cpqRackCommonEnclosureManagerRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackCommonEnclosureManagerEntry 1 }
cpqRackCommonEnclosureManagerChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackCommonEnclosureManagerEntry 2 }
cpqRackCommonEnclosureManagerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this manager within this
enclosure in the rack."
::= { cpqRackCommonEnclosureManagerEntry 3 }
cpqRackCommonEnclosureManagerEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackCommonEnclosureManagerEntry 4 }
cpqRackCommonEnclosureManagerLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The location description of the manager within the enclosure.
The string will be empty if the location could not be
determined."
::= { cpqRackCommonEnclosureManagerEntry 5 }
cpqRackCommonEnclosureManagerPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The part number of the enclosure manager.
The string will be empty if the part number could not be
determined."
::= { cpqRackCommonEnclosureManagerEntry 6 }
cpqRackCommonEnclosureManagerSparePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The spare part number of the enclosure manager.
The string will be empty if the part number could not be
determined."
::= { cpqRackCommonEnclosureManagerEntry 7 }
cpqRackCommonEnclosureManagerSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure manager.
The string will be empty if the enclosure does not report the
serial number or it could not be determined."
::= { cpqRackCommonEnclosureManagerEntry 8 }
cpqRackCommonEnclosureManagerRole OBJECT-TYPE
SYNTAX INTEGER {
standby(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies the current role of the manager."
::= { cpqRackCommonEnclosureManagerEntry 9 }
cpqRackCommonEnclosureManagerPresent OBJECT-TYPE
SYNTAX INTEGER {
other(1),
absent(2),
present(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies if the manager described is present in the system."
::= { cpqRackCommonEnclosureManagerEntry 10 }
cpqRackCommonEnclosureManagerRedundant OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notRedundant(2),
redundant(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies if the manager is in a redundant configuration."
::= { cpqRackCommonEnclosureManagerEntry 11 }
cpqRackCommonEnclosureManagerCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The condition of the manager.
This value will be one of the following:
other(1)
Manager status detection is not supported.
ok(2)
The manager is operating properly.
degraded(2)
A redundant manager is not operating properly.
failed(4)
A non-redundant manager is not operating properly."
::= { cpqRackCommonEnclosureManagerEntry 12 }
cpqRackCommonEnclosureManagerEnclosureSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure containing the manager.
The string will be empty if the enclosure does not report the
serial number or it could not be determined."
::= { cpqRackCommonEnclosureManagerEntry 13 }
cpqRackCommonEnclosureManagerUUID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The universal unique identifier string of the manager.
The string will be empty if the enclosure does not report the
UUID string."
::= { cpqRackCommonEnclosureManagerEntry 14 }
cpqRackCommonEnclosureManagerFWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The firmware revision of the enclosure manager.
The string will be empty if the enclosure does not report the
firmware revision or does not contain firmware."
::= { cpqRackCommonEnclosureManagerEntry 15 }
cpqRackServerEnclosureTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackServerEnclosureEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack enclosure information for servers."
::= { cpqRackServerEnclosure 1 }
cpqRackServerEnclosureEntry OBJECT-TYPE
SYNTAX CpqRackServerEnclosureEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A server enclosure description."
INDEX { cpqRackServerEnclosureRack , cpqRackServerEnclosureIndex }
::= { cpqRackServerEnclosureTable 1 }
cpqRackServerEnclosureEntry ::=
SEQUENCE {
cpqRackServerEnclosureRack INTEGER,
cpqRackServerEnclosureIndex INTEGER,
cpqRackServerEnclosureName DisplayString,
cpqRackServerEnclosureMaxNumBlades INTEGER,
cpqRackServerEnclosureMaxNumBladesX INTEGER,
cpqRackServerEnclosureMaxNumBladesY INTEGER
}
cpqRackServerEnclosureRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackServerEnclosureEntry 1 }
cpqRackServerEnclosureIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this server enclosure in the rack."
::= { cpqRackServerEnclosureEntry 2 }
cpqRackServerEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the server enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackServerEnclosureEntry 3 }
cpqRackServerEnclosureMaxNumBlades OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The maximum number of server blades the enclosure can contain.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackServerEnclosureEntry 4 }
cpqRackServerEnclosureMaxNumBladesX OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The maximum number of server blades in x-direction (from left to right)
the enclosure can contain."
::= { cpqRackServerEnclosureEntry 5 }
cpqRackServerEnclosureMaxNumBladesY OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The maximum number of server blades in y-direction (from top to bottom)
the enclosure can contain."
::= { cpqRackServerEnclosureEntry 6 }
cpqRackPowerEnclosureTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackPowerEnclosureEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack power enclosure information."
::= { cpqRackPowerEnclosure 1 }
cpqRackPowerEnclosureEntry OBJECT-TYPE
SYNTAX CpqRackPowerEnclosureEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack power enclosure description."
INDEX { cpqRackPowerEnclosureRack , cpqRackPowerEnclosureIndex }
::= { cpqRackPowerEnclosureTable 1 }
cpqRackPowerEnclosureEntry ::=
SEQUENCE {
cpqRackPowerEnclosureRack INTEGER,
cpqRackPowerEnclosureIndex INTEGER,
cpqRackPowerEnclosureName DisplayString,
cpqRackPowerEnclosureMgmtBoardSerialNum DisplayString,
cpqRackPowerEnclosureRedundant INTEGER,
cpqRackPowerEnclosureLoadBalanced INTEGER,
cpqRackPowerEnclosureInputPwrType INTEGER,
cpqRackPowerEnclosurePwrFeedMax INTEGER,
cpqRackPowerEnclosureCondition INTEGER,
cpqRackPowerEnclosureBladeAutopoweron INTEGER
}
cpqRackPowerEnclosureRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackPowerEnclosureEntry 1 }
cpqRackPowerEnclosureIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this power enclosure in the rack."
::= { cpqRackPowerEnclosureEntry 2 }
cpqRackPowerEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the power enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackPowerEnclosureEntry 3 }
cpqRackPowerEnclosureMgmtBoardSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure.
The string will be empty if the enclosure does not report the
serial number."
::= { cpqRackPowerEnclosureEntry 4 }
cpqRackPowerEnclosureRedundant OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notRedundant(2),
redundant(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This indicates if the power supply enclosure is in a redundant
state."
::= { cpqRackPowerEnclosureEntry 5 }
cpqRackPowerEnclosureLoadBalanced OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notLoadBalanced(2),
loadBalanced(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This indicates if the power supply enclosure is in a load
balanced state."
::= { cpqRackPowerEnclosureEntry 6 }
cpqRackPowerEnclosureInputPwrType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
singlePhase(2),
threePhase(3),
directCurrent(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This indicates type of input facility power."
::= { cpqRackPowerEnclosureEntry 7 }
cpqRackPowerEnclosurePwrFeedMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is the maximum facility power in watts.
The maximum facility power being fed to this power enclosure.
The value will be -1 if the power enclosure does not report the
value or if the value is not known."
::= { cpqRackPowerEnclosureEntry 8 }
cpqRackPowerEnclosureCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This indicates current condition of the power enclosure.
other(1)
The power enclosure condition could not be determined.
ok(2)
The power enclosure is operating normally.
degraded(3)
The power enclosure is in a degraded state. The power subsystem
may not be load balanced or may have lost redundancy."
::= { cpqRackPowerEnclosureEntry 9 }
cpqRackPowerEnclosureBladeAutopoweron OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "This indicates current condition of the power enclosure.
other(1)
The blade auto power on feature could not be determined.
disabled(2)
The enclosure will not automatically power on a blade when inserted.
enabled(3)
The enclosure will automatically power on a blade when inserted."
::= { cpqRackPowerEnclosureEntry 10 }
cpqRackLastEAEEvent OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..512))
ACCESS read-only
STATUS obsolete
DESCRIPTION "Data for the last EAE event."
::= { cpqRackServerEnclosure 2 }
cpqRackServerBladeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackServerBladeEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack server blade information."
::= { cpqRackServerBlade 1 }
cpqRackServerBladeEntry OBJECT-TYPE
SYNTAX CpqRackServerBladeEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack server blade description."
INDEX { cpqRackServerBladeRack , cpqRackServerBladeChassis, cpqRackServerBladeIndex }
::= { cpqRackServerBladeTable 1 }
cpqRackServerBladeEntry ::=
SEQUENCE {
cpqRackServerBladeRack INTEGER,
cpqRackServerBladeChassis INTEGER,
cpqRackServerBladeIndex INTEGER,
cpqRackServerBladeName DisplayString,
cpqRackServerBladeEnclosureName DisplayString,
cpqRackServerBladePartNumber DisplayString,
cpqRackServerBladeSparePartNumber DisplayString,
cpqRackServerBladePosition INTEGER,
cpqRackServerBladeHeight INTEGER,
cpqRackServerBladeWidth INTEGER,
cpqRackServerBladeDepth INTEGER,
cpqRackServerBladePresent INTEGER,
cpqRackServerBladeHasFuses INTEGER,
cpqRackServerBladeEnclosureSerialNum DisplayString,
cpqRackServerBladeSlotsUsed INTEGER,
cpqRackServerBladeSerialNum DisplayString,
cpqRackServerBladeProductId DisplayString,
cpqRackServerBladeUid DisplayString,
cpqRackServerBladeSlotsUsedX INTEGER,
cpqRackServerBladeSlotsUsedY INTEGER,
cpqRackServerBladeStatus INTEGER,
cpqRackServerBladeFaultMajor INTEGER,
cpqRackServerBladeFaultMinor INTEGER,
cpqRackServerBladeFaultDiagnosticString DisplayString,
cpqRackServerBladePowered INTEGER,
cpqRackServerBladeUIDState INTEGER,
cpqRackServerBladeSystemBIOSRevision DisplayString,
cpqRackServerBladeSystemBIOSFlashingStatus INTEGER,
cpqRackServerBladeHasManagementDevice INTEGER,
cpqRackServerBladeManagementDeviceFirmwareRevision DisplayString,
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus INTEGER,
cpqRackServerBladeDiagnosticAdaptorPresence INTEGER,
cpqRackServerBladeASREnabled INTEGER,
cpqRackServerBladeFrontIOBlankingModeStatus INTEGER,
cpqRackServerBladePOSTStatus INTEGER,
cpqRackServerBladePXEBootModeStatus INTEGER,
cpqRackServerBladePendingBootOrderChange INTEGER,
cpqRackServerBladeWattageMax INTEGER,
cpqRackServerBladeWattageAvg INTEGER,
cpqRackServerBladeWattageMin INTEGER
}
cpqRackServerBladeRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackServerBladeEntry 1 }
cpqRackServerBladeChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackServerBladeEntry 2 }
cpqRackServerBladeIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this server blade within the enclosure."
::= { cpqRackServerBladeEntry 3 }
cpqRackServerBladeName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the server blade.
The string will be empty if it could not be determined."
::= { cpqRackServerBladeEntry 4 }
cpqRackServerBladeEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the enclosure which contains the blade.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackServerBladeEntry 5 }
cpqRackServerBladePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The part number of the server blade.
The string will be empty if the part number could not be
determined."
::= { cpqRackServerBladeEntry 6 }
cpqRackServerBladeSparePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The spare part number of the server blade.
The string will be empty if the part number could not be
determined."
::= { cpqRackServerBladeEntry 7 }
cpqRackServerBladePosition OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The position or slot number of the server blade within the
server enclosure.
This will be -1 if the server enclosure does not report the
information or it could not be determined."
::= { cpqRackServerBladeEntry 8 }
cpqRackServerBladeHeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The height dimension of the rack space taken by the server
blade expressed in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackServerBladeEntry 9 }
cpqRackServerBladeWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The width dimension of the rack space taken by the server
blade expressed in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackServerBladeEntry 10 }
cpqRackServerBladeDepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The depth dimension of the rack space taken by the server
blade expressed in millimeters.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackServerBladeEntry 11 }
cpqRackServerBladePresent OBJECT-TYPE
SYNTAX INTEGER {
other(1),
absent(2),
present(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies if the server blade described is present in the
enclosure."
::= { cpqRackServerBladeEntry 12 }
cpqRackServerBladeHasFuses OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The server blade contains fuses.
This will be true(2) is the server blade contains fuses.
The cpqRackCommonEnclosureFuseTable will contain the fuse
specific information.
Match the cpqRackServerBladeEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureFanTable to get complete
information on the fuses."
::= { cpqRackServerBladeEntry 13 }
cpqRackServerBladeEnclosureSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure which contains the blade.
The string will be empty if the enclosure does not report the
serial number or it could not be determined."
::= { cpqRackServerBladeEntry 14 }
cpqRackServerBladeSlotsUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The number of slot positions occupied by this server blade. This
is used to indicate a server blade which may obscure an adjacent
blade slot.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackServerBladeEntry 15 }
cpqRackServerBladeSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the server blade.
The string will be empty if the system does not report the
serial number function."
::= { cpqRackServerBladeEntry 16 }
cpqRackServerBladeProductId OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The product id string of the server blade.
The string will be empty if the system does not report the
product id function."
::= { cpqRackServerBladeEntry 17 }
cpqRackServerBladeUid OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The server blade unique identifier (UUID).
The string will be empty if the blade does not report the
UUID or if it could not be determined."
::= { cpqRackServerBladeEntry 18 }
cpqRackServerBladeSlotsUsedX OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The number of slot positions in x-direction (from left to right)
occupied by this server blade. This is used to indicate a server blade
which may obscure an adjacent blade slot.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackServerBladeEntry 19 }
cpqRackServerBladeSlotsUsedY OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The number of slot positions in y-direction (from top to bottom)
occupied by this server blade. This is used to indicate a server blade
which may obscure an adjacent blade slot.
This will be -1 if the rack does not report the information or
it could not be determined."
::= { cpqRackServerBladeEntry 20 }
cpqRackServerBladeStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "The health status of the blade.
This will be other(1) if the rack does not report the information
or if it could not be determined."
::= { cpqRackServerBladeEntry 21 }
cpqRackServerBladeFaultMajor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "The major fault code of the blade fault
reported by the enclosure manager.
This will be -1 if the rack does not report the information or
if it could not be determined."
::= { cpqRackServerBladeEntry 22 }
cpqRackServerBladeFaultMinor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "The minor fault code of the blade fault
reported by the enclosure manager.
This will be -1 if the rack does not report the information or
if it could not be determined."
::= { cpqRackServerBladeEntry 23 }
cpqRackServerBladeFaultDiagnosticString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The server blade fault diagnostic string. This will contain a probable
cause and potential diagnostic action to be taken to remedy the fault condition.
The string will be empty if the blade does not report the
diagnostic string or if it could not be determined."
::= { cpqRackServerBladeEntry 24 }
cpqRackServerBladePowered OBJECT-TYPE
SYNTAX INTEGER {
other(1),
on(2),
off(3),
powerStagedOff(4),
reboot(5)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "The power state of the blade.
This will be other(1) if the rack does not report the information or if it could not be determined."
::= { cpqRackServerBladeEntry 25 }
cpqRackServerBladeUIDState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
none(2),
ledOn(3),
ledOff(4)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "The Unit Identifier LED.
This value will be one of the following:
other(1)
The state of the LED could not be determined. Setting the
LED state is not allowed.
none(2)
The LED is not present. Setting LED state is not allowed.
ledOn(3)
The LED is present and ON. The LED can be turned off
by setting the cpqRackServerBladeUIDState to ledOff(4).
ledOff(4)
The LED is present and OFF. The LED can be turned on
by setting the cpqRackServerBladeUIDState to ledOn(3).
"
::= { cpqRackServerBladeEntry 26 }
cpqRackServerBladeSystemBIOSRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The server blade system bios revision.
The string will be empty if the blade does not report the
system bios revision or if it could not be determined."
::= { cpqRackServerBladeEntry 27 }
cpqRackServerBladeSystemBIOSFlashingStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
normal(2),
flashing(3)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "Blade server system BIOS flashing / flash mode status indication.
This will be other(1) if the rack does not report the information or if it could not be determined."
::= { cpqRackServerBladeEntry 28 }
cpqRackServerBladeHasManagementDevice OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "The blade server contains one or more management devices.
This will be true(2) if the blade server contains managers and false (1) if not
or if it can't be detected."
::= { cpqRackServerBladeEntry 29 }
cpqRackServerBladeManagementDeviceFirmwareRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The server blade management device firwmware revision.
The string will be empty if the blade does not report the
management device firwmware revision or if it could not be determined."
::= { cpqRackServerBladeEntry 30 }
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
normal(2),
flashing(3)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "Blade server management device firwmware flashing / flash mode status indication.
This will be other(1) if the rack does not report this information or if it could not be determined."
::= { cpqRackServerBladeEntry 31 }
cpqRackServerBladeDiagnosticAdaptorPresence OBJECT-TYPE
SYNTAX INTEGER {
other(1),
absent(2),
present(3)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "This specifies if a blade diagnostic adaptor is currently plugged into the system."
::= { cpqRackServerBladeEntry 32 }
cpqRackServerBladeASREnabled OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates whether the target blade server has Automatic Service Recovery feature enabled.
This will be true(2) if the blade server has this feature eanbled and false (1) if not
or if it can't be detected."
::= { cpqRackServerBladeEntry 33 }
cpqRackServerBladeFrontIOBlankingModeStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
inactive(2),
active(3)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates whether the target blade server has the front IO ports blanking feature enabled.
This will be Active(3) if the blade server has this feature eanbled, Inactive (2) if not,
or Unknown(1) if it can't be determined."
::= { cpqRackServerBladeEntry 34 }
cpqRackServerBladePOSTStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
started(2),
completed(3),
failed(4)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "Blade server power-on self test (POST) status.
This value will be one of the following:
other(1)
The state of the blade POST could not be determined.
started(2)
Blade has started Power-on-self-test (POST) process.
completed(3)
Blade has finished Power-on-self-test (POST) process.
failed(4)
Blade has failed to complete Power-on-self-test (POST) process and halted.
This will be other(1) if the rack does not report this information or if it could not be determined."
::= { cpqRackServerBladeEntry 35 }
cpqRackServerBladePXEBootModeStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
inactive(2),
active(3)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates whether the target blade server is in PXE boot mode.
This will be Active(3) if the blade server has this feature enbled, Inactive (2) if not,
or Unknown(1) if it can't be determined."
::= { cpqRackServerBladeEntry 36 }
cpqRackServerBladePendingBootOrderChange OBJECT-TYPE
SYNTAX INTEGER {
other(1),
none(2),
firstPXE(3),
firstHDD(4),
firstRBSU(5),
oncePXE(6),
onceHDD(7),
onceRBSU(8),
alwaysPXE(9),
alwaysHDD(10),
alwaysRBSU(11)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "Blade server pending boot order setting change state.
This value will be one of the following:
other(1) - Unknown or cannot be determined
none(2) - No Changes
firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First
firstHDD(4) - First Boot To Local HD
firstRBSU(5) - First Boot To ROM Based Setup Utility
oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once
onceHDD(7) - Boot To Local HD Once
onceRBSU(8) - Boot To ROM Based Setup Utility Once
alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE)
alwaysHDD(10) - Always Boot To Local HD
alwaysRBSU(11) - Always Boot To ROM Based Setup Utility
This will be other(1) if the rack does not report this information or if it could not be determined."
::= { cpqRackServerBladeEntry 37 }
cpqRackServerBladeWattageMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "Maximum wattage the server has consumed during this power cycle."
::= { cpqRackServerBladeEntry 38 }
cpqRackServerBladeWattageAvg OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "Average wattage the server is consuming, averaged over a period defined by the product."
::= { cpqRackServerBladeEntry 39 }
cpqRackServerBladeWattageMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "Minimum wattage the server has consumed, computed from a period defined by the product. Value
will be 0 if not supported, but other wattage values are supported."
::= { cpqRackServerBladeEntry 40 }
cpqRackServerNetworkingTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackServerNetworkingEntry
ACCESS read-only
STATUS obsolete
DESCRIPTION "A table of rack server networking information."
::= { cpqRackServerNetworking 1 }
cpqRackServerNetworkingEntry OBJECT-TYPE
SYNTAX CpqRackServerNetworkingEntry
ACCESS read-only
STATUS obsolete
DESCRIPTION "A rack server networking description."
INDEX { cpqRackServerNetworkingRack , cpqRackServerNetworkingChassis, cpqRackServerNetworkingIndex }
::= { cpqRackServerNetworkingTable 1 }
cpqRackServerNetworkingEntry ::=
SEQUENCE {
cpqRackServerNetworkingRack INTEGER,
cpqRackServerNetworkingChassis INTEGER,
cpqRackServerNetworkingIndex INTEGER,
cpqRackServerNetworkingName DisplayString,
cpqRackServerNetworkingEnclosureName DisplayString,
cpqRackServerNetworkingEthernetInterfaces INTEGER,
cpqRackServerNetworkingEthernetMACAddress DisplayString
}
cpqRackServerNetworkingRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackServerNetworkingEntry 1 }
cpqRackServerNetworkingChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackServerNetworkingEntry 2 }
cpqRackServerNetworkingIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "A number that uniquely specifies this server within the enclosure."
::= { cpqRackServerNetworkingEntry 3 }
cpqRackServerNetworkingName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The name of the server.
The string will be empty if it could not be determined."
::= { cpqRackServerNetworkingEntry 4 }
cpqRackServerNetworkingEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The name of the enclosure which contains the server.
The string will be empty if the enclosure does not report the
name or if it could not be determined."
::= { cpqRackServerNetworkingEntry 5 }
cpqRackServerNetworkingEthernetInterfaces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "A number that specifies the amount of
Ethernet network interfaces in the server."
::= { cpqRackServerNetworkingEntry 6 }
cpqRackServerNetworkingEthernetMACAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The MAC address for the Ethernet NIC populated in the server.
The string will be empty if it could not be determined."
::= { cpqRackServerNetworkingEntry 7 }
cpqRackServerTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackServerTempSensorEntry
ACCESS read-only
STATUS obsolete
DESCRIPTION "A table of rack server temperature sensor information."
::= { cpqRackServerTempSensor 1 }
cpqRackServerTempSensorEntry OBJECT-TYPE
SYNTAX CpqRackServerTempSensorEntry
ACCESS read-only
STATUS obsolete
DESCRIPTION "A rack server temperature sensor description."
INDEX { cpqRackServerTempSensorRack , cpqRackServerTempSensorChassis, cpqRackServerTempSensorIndex }
::= { cpqRackServerTempSensorTable 1 }
cpqRackServerTempSensorEntry ::=
SEQUENCE {
cpqRackServerTempSensorRack INTEGER,
cpqRackServerTempSensorChassis INTEGER,
cpqRackServerTempSensorIndex INTEGER,
cpqRackServerTempSensorName DisplayString,
cpqRackServerTempSensorEnclosureName DisplayString,
cpqRackServerTempSensorCount INTEGER,
cpqRackServerTempSensorLocation DisplayString,
cpqRackServerTempSensorCurrent INTEGER,
cpqRackServerTempSensorThreshold INTEGER,
cpqRackServerTempSensorCondition INTEGER,
cpqRackServerTempSensorType INTEGER
}
cpqRackServerTempSensorRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackServerTempSensorEntry 1 }
cpqRackServerTempSensorChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "A number that uniquely specifies this enclosure in the rack."
::= { cpqRackServerTempSensorEntry 2 }
cpqRackServerTempSensorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "A number that uniquely specifies this server within the enclosure."
::= { cpqRackServerTempSensorEntry 3 }
cpqRackServerTempSensorName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The name of the server.
The string will be empty if it could not be determined."
::= { cpqRackServerTempSensorEntry 4 }
cpqRackServerTempSensorEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The name of the enclosure which contains the server.
The string will be empty if the enclosure does not report the
name or if it could not be determined."
::= { cpqRackServerTempSensorEntry 5 }
cpqRackServerTempSensorCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "A number that specifies the amount of
temperature sensors in the server."
::= { cpqRackServerTempSensorEntry 6 }
cpqRackServerTempSensorLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS obsolete
DESCRIPTION "The location description of the temperature sensor within the
blade server.
The string will be empty if it could not be determined."
::= { cpqRackServerTempSensorEntry 7 }
cpqRackServerTempSensorCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "This is the current temperature sensor reading in degrees
celsius.
If this value cannot be determined by software, then a value
of -1 will be returned."
::= { cpqRackServerTempSensorEntry 8 }
cpqRackServerTempSensorThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION "This is the threshold temperature sensor setting
in degrees celsius. This is the temperature in which the
sensor will be considered to be in a tripped state this
causing some action to occur depending on the type of
the sensor. The action of temperature sensor threshold
will be indicated by the cpqRackServerTempSensorType
item. If the type is blowout(5), then the temperature sensor
will cause the fans to speed up. If the type is caution(9),
then the temperature sensor is in a degraded state. If the
type is critical(15), then the enclosure will be considered
as in a failed state.
If this value cannot be determined by software, then a value
of -1 will be returned."
::= { cpqRackServerTempSensorEntry 9 }
cpqRackServerTempSensorCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within the normal operating range.
degraded(3)
The temperature sensor is outside of the normal operating range.
failed(4)
The temperature sensor detects a condition that could
possibly overheat the system.
The system will automatically shutdown if the failed(4) condition
results, so it is unlikely that this value will ever be returned
by the agent."
::= { cpqRackServerTempSensorEntry 10 }
cpqRackServerTempSensorType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
blowout(5),
caution(9),
critical(15)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION "This specifies the type of this instance of temperature
sensor.
This value will be one of the following:
other(1)
Temperature threshold type could not be determined.
blowout(5)
If a blowout(5) temperature sensor reaches its threshold,
the fan or fans in the area of the temperature sensor will
increase in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.
caution(9)
If a caution(9) temperature sensor reaches its threshold, the
cpqRackServerTempSensorCondition will be set to degraded(3)
and the system will either continue or shutdown depending
on the local blade server policy settings.
critical(15)
If a critical(15) temperature sensor reaches its threshold,
cpqRackServerTempSensorCondition will be set to failed(4)
and the blade server will shutdown."
::= { cpqRackServerTempSensorEntry 11 }
cpqRackPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackPowerSupplyEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack power supply information."
::= { cpqRackPowerSupply 1 }
cpqRackPowerSupplyEntry OBJECT-TYPE
SYNTAX CpqRackPowerSupplyEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack power supply description."
INDEX { cpqRackPowerSupplyRack , cpqRackPowerSupplyChassis, cpqRackPowerSupplyIndex }
::= { cpqRackPowerSupplyTable 1 }
cpqRackPowerSupplyEntry ::=
SEQUENCE {
cpqRackPowerSupplyRack INTEGER,
cpqRackPowerSupplyChassis INTEGER,
cpqRackPowerSupplyIndex INTEGER,
cpqRackPowerSupplyEnclosureName DisplayString,
cpqRackPowerSupplySerialNum DisplayString,
cpqRackPowerSupplyPartNumber DisplayString,
cpqRackPowerSupplySparePartNumber DisplayString,
cpqRackPowerSupplyFWRev DisplayString,
cpqRackPowerSupplyMaxPwrOutput INTEGER,
cpqRackPowerSupplyCurPwrOutput INTEGER,
cpqRackPowerSupplyPosition INTEGER,
cpqRackPowerSupplyIntakeTemp INTEGER,
cpqRackPowerSupplyExhaustTemp INTEGER,
cpqRackPowerSupplyStatus INTEGER,
cpqRackPowerSupplyInputLineStatus INTEGER,
cpqRackPowerSupplyPresent INTEGER,
cpqRackPowerSupplyCondition INTEGER,
cpqRackPowerSupplyEnclosureSerialNum DisplayString
}
cpqRackPowerSupplyRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackPowerSupplyEntry 1 }
cpqRackPowerSupplyChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this power enclosure in the rack."
::= { cpqRackPowerSupplyEntry 2 }
cpqRackPowerSupplyIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this power supply in the enclosure."
::= { cpqRackPowerSupplyEntry 3 }
cpqRackPowerSupplyEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the power supply enclosure in which this power supply
resides.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackPowerSupplyEntry 4 }
cpqRackPowerSupplySerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the power supply.
The string will be empty if the power supply does not report the
serial number."
::= { cpqRackPowerSupplyEntry 5 }
cpqRackPowerSupplyPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The part number of the power supply.
The string will be empty if the power supply does not report this
function."
::= { cpqRackPowerSupplyEntry 6 }
cpqRackPowerSupplySparePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The spare part number of the power supply.
The string will be empty if the power supply does not report this
function."
::= { cpqRackPowerSupplyEntry 7 }
cpqRackPowerSupplyFWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The firmware revision of the power supply.
The string will be empty if the power supply does not report the
firmware revision."
::= { cpqRackPowerSupplyEntry 8 }
cpqRackPowerSupplyMaxPwrOutput OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The maximum power output of the power supply in watts.
The value will be -1 if the power supply does not report the
value."
::= { cpqRackPowerSupplyEntry 9 }
cpqRackPowerSupplyCurPwrOutput OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current power output of the power supply in watts.
The value will be -1 if the power supply does not report the
value."
::= { cpqRackPowerSupplyEntry 10 }
cpqRackPowerSupplyPosition OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The position of the power supply within the power enclosure.
This will be -1 if the power enclosure does not report the
power supply information or it could not be determined."
::= { cpqRackPowerSupplyEntry 11 }
cpqRackPowerSupplyIntakeTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current air temperature at the intake of the power supply
in degrees celsius.
The value will be -1 if the power supply does not report the
value."
::= { cpqRackPowerSupplyEntry 12 }
cpqRackPowerSupplyExhaustTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current air temperature at the exhaust of the power supply
in degrees celsius.
The value will be -1 if the power supply does not report the
value."
::= { cpqRackPowerSupplyEntry 13 }
cpqRackPowerSupplyStatus OBJECT-TYPE
SYNTAX INTEGER {
noError(1),
generalFailure(2),
bistFailure(3),
fanFailure(4),
tempFailure(5),
interlockOpen(6),
epromFailed(7),
vrefFailed(8),
dacFailed(9),
ramTestFailed(10),
voltageChannelFailed(11),
orringdiodeFailed(12),
brownOut(13),
giveupOnStartup(14),
nvramInvalid(15),
calibrationTableInvalid(16)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The status of the power supply."
::= { cpqRackPowerSupplyEntry 14 }
cpqRackPowerSupplyInputLineStatus OBJECT-TYPE
SYNTAX INTEGER {
noError(1),
lineOverVoltage(2),
lineUnderVoltage(3),
lineHit(4),
brownOut(5),
linePowerLoss(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The status of line input power."
::= { cpqRackPowerSupplyEntry 15 }
cpqRackPowerSupplyPresent OBJECT-TYPE
SYNTAX INTEGER {
other(1),
absent(2),
present(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies if the power supply described is present in the
enclosure."
::= { cpqRackPowerSupplyEntry 16 }
cpqRackPowerSupplyCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The condition of the power supply.
This value will be one of the following:
other(1)
The status could not be determined or not present.
ok(2)
The power supply is operating normally.
degraded(3)
A temperature sensor, fan or other power supply component is
outside of normal operating range.
failed(4)
A power supply component detects a condition that could
possibly damage the system."
::= { cpqRackPowerSupplyEntry 17 }
cpqRackPowerSupplyEnclosureSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the power supply enclosure in which this
power supply resides.
The string will be empty if the enclosure does not report the
serial number or it could not be determined."
::= { cpqRackPowerSupplyEntry 18 }
cpqRackNetConnectorTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqRackNetConnectorEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of rack network connector information."
::= { cpqRackNetConnector 1 }
cpqRackNetConnectorEntry OBJECT-TYPE
SYNTAX CpqRackNetConnectorEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A rack network connector description."
INDEX { cpqRackNetConnectorRack , cpqRackNetConnectorChassis, cpqRackNetConnectorIndex }
::= { cpqRackNetConnectorTable 1 }
cpqRackNetConnectorEntry ::=
SEQUENCE {
cpqRackNetConnectorRack INTEGER,
cpqRackNetConnectorChassis INTEGER,
cpqRackNetConnectorIndex INTEGER,
cpqRackNetConnectorEnclosureName DisplayString,
cpqRackNetConnectorName DisplayString,
cpqRackNetConnectorModel DisplayString,
cpqRackNetConnectorSerialNum DisplayString,
cpqRackNetConnectorPartNumber DisplayString,
cpqRackNetConnectorSparePartNumber DisplayString,
cpqRackNetConnectorFWRev DisplayString,
cpqRackNetConnectorType INTEGER,
cpqRackNetConnectorLocation DisplayString,
cpqRackNetConnectorPresent INTEGER,
cpqRackNetConnectorHasFuses INTEGER,
cpqRackNetConnectorEnclosureSerialNum DisplayString,
cpqRackNetConnectorTechnologyType INTEGER,
cpqRackNetConnectorDeviceType INTEGER
}
cpqRackNetConnectorRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this rack."
::= { cpqRackNetConnectorEntry 1 }
cpqRackNetConnectorChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this server enclosure in the rack."
::= { cpqRackNetConnectorEntry 2 }
cpqRackNetConnectorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A number that uniquely specifies this network connector in the rack."
::= { cpqRackNetConnectorEntry 3 }
cpqRackNetConnectorEnclosureName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the network connector enclosure.
The string will be empty if the enclosure does not report the
name or it could not be determined."
::= { cpqRackNetConnectorEntry 4 }
cpqRackNetConnectorName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the network connector.
The string will be empty if the network connector does not report the
name or it could not be determined."
::= { cpqRackNetConnectorEntry 5 }
cpqRackNetConnectorModel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The model name of the network connector.
The string will be empty if the network connector does not report the
model information."
::= { cpqRackNetConnectorEntry 6 }
cpqRackNetConnectorSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the network connector.
The string will be empty if the network connector does not report the
serial number."
::= { cpqRackNetConnectorEntry 7 }
cpqRackNetConnectorPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The part number of the network connector.
The string will be empty if the enclosure does not report this
function."
::= { cpqRackNetConnectorEntry 8 }
cpqRackNetConnectorSparePartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The spare part number of the network connector.
The string will be empty if the enclosure does not report this
function."
::= { cpqRackNetConnectorEntry 9 }
cpqRackNetConnectorFWRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The firmware revision of the network connector.
The string will be empty if the network connector does not report the
firmware revision."
::= { cpqRackNetConnectorEntry 10 }
cpqRackNetConnectorType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
passive(2),
active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of network connector within the enclosure."
::= { cpqRackNetConnectorEntry 11 }
cpqRackNetConnectorLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The location of the network connector within the enclosure."
::= { cpqRackNetConnectorEntry 12 }
cpqRackNetConnectorPresent OBJECT-TYPE
SYNTAX INTEGER {
other(1),
absent(2),
present(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This specifies if the network connector described is present in the
enclosure."
::= { cpqRackNetConnectorEntry 13 }
cpqRackNetConnectorHasFuses OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The network connector contains fuses.
This will be true(2) is the network connector contains fuses.
The cpqRackCommonEnclosureFuseTable will contain the fuse
specific information.
Match the cpqRackNetworkEnclosureSerialNum in this table to the
serial number in the cpqRackCommonEnclosureFusTable to get complete
information on the fuses."
::= { cpqRackNetConnectorEntry 14 }
cpqRackNetConnectorEnclosureSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the enclosure containing the network connector.
The string will be empty if the enclosure does not report the
serial number or it could not be determined."
::= { cpqRackNetConnectorEntry 15 }
cpqRackNetConnectorTechnologyType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
passive(2),
active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of network connector within the enclosure."
::= { cpqRackNetConnectorEntry 16 }
cpqRackNetConnectorDeviceType OBJECT-TYPE
SYNTAX INTEGER {
noconnect(1),
network(2),
fibrechannel(3),
sas(4),
inifiband(5),
pciexpress(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of interrconnect in the enclosure.
This will be -1 if it is not reported or can not be deteremined."
::= { cpqRackNetConnectorEntry 17 }
cpqRackSystemObjectIdentification OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The hardware identification string.
The string will reported by the rack firmware."
::= { cpqRackSysObjID 1 }
cpqRackNameChanged TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackSerialNum, cpqRackTrapSequenceNum }
--#SUMMARY "The rack name has changed to %s."
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Rack Serial Number: #"
--#TYPE "Rack name changed (22001)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackNameChangeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.RackTrapNoticeHandler"
DESCRIPTION "Rack name has changed. This trap signifies that an agent or utility has changed the name of the rack. Each of the server blades in each of the enclosure within the rack will be updated to reflect the new rack name. It may take several minutes for the rack name change to be propagated throughout the entire rack. User Action: None."
::= 22001
cpqRackEnclosureNameChanged TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureModel, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure name has changed to %s in rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Model: #"
--#TYPE "Enclosure name changed (22002)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclNameChangeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure name has changed. This trap signifies that an agent or utility has changed the name of an enclosure within the rack. Each of the components within the rack will be updated to reflect the new enclosure name. It may take several minutes for the enclosure name change to be propagated throughout the entire enclosure. User Action: None."
::= 22002
cpqRackEnclosureRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureModel, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s has been removed from rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Model: # $V7V#Serial Number: #"
--#TYPE "Enclosure removed (22003)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure has been removed. This trap signifies that an enclosure has been removed from the rack. User Action: None."
::= 22003
cpqRackEnclosureInserted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureModel, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s has been inserted into rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Model: # $V7V#Serial Number: #"
--#TYPE "Enclosure inserted (22004)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure has been inserted. This trap signifies that an enclosure has been inserted into the rack. User Action: None."
::= 22004
cpqRackEnclosureTempFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTempLocation, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to failed."
--#ARGUMENTS {4,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Location: #"
--#TYPE "Enclosure temperature failed (22005)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure temperature status has been set to failed. This trap signifies that a enclosure temperature sensor has been tripped indicating an overheat condition. User Action: Shutdown the enclosure and possibly the rack as soon as possible. Insure all fans are working properly and that air flow in the rack has not been blocked."
::= 22005
cpqRackEnclosureTempDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTempLocation, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to degraded."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
--#TYPE "Enclosure temperature degraded (22006)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure temperature status has been set to degraded. This trap signifies that an enclosure temperature sensor has been tripped indicating a possible overheat condition. User Action: Shutdown the enclosure and possibly the rack as soon as possible. Insure all fans are working properly and that air flow in the rack has not been blocked."
::= 22006
cpqRackEnclosureTempOk TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTempLocation, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to ok."
--#ARGUMENTS {4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Position: #"
--#TYPE "Enclosure temperature ok (22007)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure temperature status has been set to ok. This trap signifies that an enclosure temperature sensor has returned to normal. User Action: None."
::= 22007
cpqRackEnclosureFanFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s fan in rack %s has been set to failed."
--#ARGUMENTS {4,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
--#TYPE "Enclosure fan failed (22008)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible."
::= 22008
cpqRackEnclosureFanDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s fan in rack %s has been set to degraded."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
--#TYPE "Enclosure fan degraded (22009)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure fan status has been set to degraded. This trap signifies that an enclosure fan has failed but other fans in the redundant fan group are still operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible."
::= 22009
cpqRackEnclosureFanOk TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s fan in rack %s has been set to ok."
--#ARGUMENTS {4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
--#TYPE "Enclosure fan ok (22010)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure fan status has been set to ok. This trap signifies that an enclosure fan has returned to normal operation. User Action: None."
::= 22010
cpqRackEnclosureFanRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s fan in rack %s has been removed."
--#ARGUMENTS {4,2}
--#SEVERITY MINOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Location: #"
--#TYPE "Enclosure fan removed (22011)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure fan has been removed. User Action: None."
::= 22011
cpqRackEnclosureFanInserted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureFanLocation, cpqRackCommonEnclosureFanSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The enclosure %s fan in rack %s has been inserted."
--#ARGUMENTS {4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: # $V7V#Fan Location: #"
--#TYPE "Enclosure fan inserted (22012)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The enclosure fan has been inserted. User Action: None."
::= 22012
cpqRackPowerSupplyFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to failed."
--#ARGUMENTS {6,4,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#PS Serial Number: # $V7V#Position: # $V10V#Enclosure Serial Number: #"
--#TYPE "Rack power supply failed (22013)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The power supply status has been set to failed. This trap signifies that a power supply has failed. User Action: Replace the power supply as soon as possible."
::= 22013
cpqRackPowerSupplyDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to degraded."
--#ARGUMENTS {6,4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#PS Serial Number: # $V7V#Position: # $V10V#Enclosure Serial Number: #"
--#TYPE "Rack power supply degraded (22014)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The power supply status has been set to degraded. This trap signifies that a power supply has degraded. User Action: Replace the power supply as soon as possible."
::= 22014
cpqRackPowerSupplyOk TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to ok."
--#ARGUMENTS {6,4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#PS Serial Number: # $V7V#PS Position: # $V10V#Enclosure Serial Number: #"
--#TYPE "Rack power supply ok (22015)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The power supply status has been set to ok. This trap signifies that a power supply has returned to normal operation. User Action: None."
::= 22015
cpqRackPowerSupplyRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been removed."
--#ARGUMENTS {6,4,2}
--#SEVERITY MINOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#PS Enclosure Name: # $V6V#PS Serial Number: # $V7V#PS Position: # $V10V#Enclosure Serial Number: #"
--#TYPE "Rack power supply removed (22016)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The power supply has been removed. User Action: None."
::= 22016
cpqRackPowerSupplyInserted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplySerialNum, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been inserted."
--#ARGUMENTS {6,4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#PS Enclosure Name: # $V6V#PS Serial Number: # $V7V#PS Position: # $V10V#Enclosure Serial Number: #"
--#TYPE "Rack power supply inserted (22017)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The power supply has been inserted. User Action: None."
::= 22017
cpqRackPowerSubsystemNotRedundant TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The power subsystem in enclosure %s in rack %s is no longer redundant."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
--#TYPE "Rack power subsystem not redundant (22018)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The rack power subsystem is no longer in a redundant state. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state."
::= 22018
cpqRackPowerSubsystemLineVoltageProblem TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerSupplyEnclosureName, cpqRackPowerSupplyPosition, cpqRackPowerSupplyFWRev, cpqRackPowerSupplyInputLineStatus, cpqRackPowerSupplySparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The rack power supply detected an input line voltage problem in power supply %s, enclosure %s, rack %s."
--#ARGUMENTS {5,4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#PS Position: # $V8V#Line Status: # $V10V#Enclosure Serial Number: #"
--#TYPE "Rack power supply input voltage problem (22019)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.PwrSupplyTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as soon as possible."
::= 22019
cpqRackPowerSubsystemOverloadCondition TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackPowerEnclosureName, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The power subsystem in enclosure %s in rack %s is in an overload condition."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V7V#Serial Number: #"
--#TYPE "Rack power subsystem overload condition (22020)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The rack power subsystem overload condition. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state."
::= 22020
cpqRackPowerShedAutoShutdown TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "The server shutdown due to lack of power blade %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,4,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Enclosure Serial Number: #"
--#TYPE "Server shutdown due to power shedding (22021)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.BladeTrapNoticeHandler"
DESCRIPTION "Server shutdown due to power shedding. The server blade was shutdown due to a lack of power. User Action: Check power connections or add power supplies."
::= 22021
cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,4,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Serial Number: #"
--#TYPE "Server power on prevented to preserve redundancy (22022)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies."
::= 22022
cpqRackServerPowerOnFailedNotEnoughPower TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,4,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Serial Number: #"
--#TYPE "Inadequate power to power on (22023)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Inadequate power to power on. There is not enough power to power on the server blade. User Action: Check power connections or add power supplies."
::= 22023
cpqRackServerPowerOnFailedEnclosureNotFound TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,4,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Enclosure Serial Number: #"
--#TYPE "Inadequate power to power on (22024)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check server enclosure connections or add power supplies."
::= 22024
cpqRackServerPowerOnFailedPowerChassisNotFound TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,4,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Serial Number: #"
--#TYPE "Inadequate power to power on (22025)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Inadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found. User Action: Check power enclosure connections or add power supplies."
::= 22025
cpqRackServerPowerOnManualOverride TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Server power on via manual override on blade %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Position: # $V8V#Serial Number: #"
--#TYPE "Server power on via manual override (22026)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Server power on via manual override. The server blade was powered on by a manual override. User Action: None."
::= 22026
cpqRackFuseOpen TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureFuseLocation, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Fuse open fuse %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Location: # $V8V#Serial Number: #"
--#TYPE "Fuse open (22027)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Fuse open. The fuse has been tripped. User Action: Check enclosure and / or blade power connections and reset the fuse."
::= 22027
cpqRackServerBladeRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,6,4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Blade Name: # $V7V#Postion: # $V9V#Enclosure Serial Number: #"
--#TYPE "Server blade removed (22028)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeRemovedTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Server blade removed. The server blade has been removed from the enclosure. User Action: None."
::= 22028
cpqRackServerBladeInserted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5,6,4,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Blade Name: # $V7V#Postion: # $V9V#Serial Number: #"
--#TYPE "Server blade inserted (22029)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Server blade inserted. The server blade has been inserted into the enclosure. User Action: None."
::= 22029
cpqRackPowerChassisNotLoadBalanced TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Power subsystem not load balanced in enclosure %s, in rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
--#TYPE "Power subsystem not load balanced (22030)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Power subsystem not load balanced. The power subsystem is out of balance for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed."
::= 22030
cpqRackPowerChassisDcPowerProblem TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Power subsystem DC power problem in enclosure %s, in rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
--#TYPE "Power subsystem DC power problem (22031)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
::= 22031
cpqRackPowerChassisAcFacilityPowerExceeded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Power subsystem AC facility input power exceeded in enclosure %s, in rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
--#TYPE "Power subsystem AC facility input power exceeded (22032)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Power subsystem AC facility input power exceeded. There is a power subsystem Power subsystem AC facility input power exceeded for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
::= 22032
cpqRackPowerUnknownPowerConsumption TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Unknown power consumption in rack %s."
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Serial Number: #"
--#TYPE "Unknown power consumption (22033)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.RackTrapNoticeHandler"
DESCRIPTION "Unknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
::= 22033
cpqRackPowerChassisLoadBalancingWireMissing TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Power subsystem load balancing wire missing for enclosure %s, in rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
--#TYPE "Power subsystem load balancing wire missing (22034)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Power subsystem load balancing wire missing. The power subsystem load balancing wire missing. User Action: Connect the load balancing wire."
::= 22034
cpqRackPowerChassisTooManyPowerChassis TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Power subsystem has too may power enclosures %s, in rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
--#TYPE "Power subsystem has too may power enclosures (22035)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.RackTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.RackTrapNoticeHandler"
DESCRIPTION "Power subsystem has too may power enclosures. The maximum number of power enclosures has been exceeded. User Action: Remove the extra power enclosure."
::= 22035
cpqRackPowerChassisConfigError TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureSparePartNumber, cpqRackCommonEnclosureTrapSequenceNum }
--#SUMMARY "Power subsystem has been improperly configured in enclosure %s, in rack %s."
--#ARGUMENTS {4,2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Serial Number: #"
--#TYPE "Power subsystem improperly configured (22036)"
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Power subsystem improperly configured. The power subsystem has been improperly configured. User Action: Check the cabling of the power enclosure."
::= 22036
cpqRackEnclosureManagerDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Enclosure manager degraded (22037)"
--#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
--#ARGUMENTS {4, 2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The Onboard Administrator status has been set to degraded. This trap signifies that an Onboard Administrator has failed but the other Onboard Administrator is still operating.
User Action: Replace the Onboard Administrator as soon as possible."
::= 22037
cpqRackEnclosureManagerOk TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Onboard Administrator ok (22038)"
--#SUMMARY "The Onboard Administrator %s in rack %s has been set to ok."
--#ARGUMENTS {4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The Onboard Administrator status has been set to ok. This trap signifies that an Onboard Administrator has returned to normal operation.
User Action: None."
::= 22038
cpqRackEnclosureManagerRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Onboard Administrator removed (22039)"
--#SUMMARY "The Onboard Administrator %s in rack %s has been removed."
--#ARGUMENTS {4, 2}
--#SEVERITY MINOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The Onboard Administrator has been removed.
User Action: None."
::= 22039
cpqRackEnclosureManagerInserted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Onboard Administrator inserted (22040)"
--#SUMMARY "The Onboard Administrator %s in rack %s has been inserted."
--#ARGUMENTS {4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The Onboard Administrator has been inserted.
User Action: None."
::= 22040
cpqRackManagerPrimaryRole TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackCommonEnclosureName, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureManagerLocation, cpqRackCommonEnclosureManagerSparePartNumber, cpqRackCommonEnclosureManagerSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Onboard Administrator has taken the role of primary (UID) (22041)"
--#SUMMARY "Onboard Administrator has taken the role of primary, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 3}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Enclosure Serial Number: # $V7V#Manager Location: # $V8V#Manager Spare Part Number: # $V9V#Manager Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.OARoleTrapHandler"
DESCRIPTION "The Onboard Administrator has taken the role of primary.
User Action: None."
::= 22041
cpqRackServerBladeEKeyingFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server Blade ekeying failed (22042)"
--#SUMMARY "Server blade %s ekeying failed in position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.BladeTrapNoticeHandler"
DESCRIPTION "The server blade e-keying has failed. This trap signifies that a server blade e-keying has failed and there is a port mapping problem between a server mezz card and the interconnect.
User Action: Reconfigure server blade mezz cards."
::= 22042
cpqRackServerBladeEKeyingOK TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server Blade ekeying ok (22043)"
--#SUMMARY "Server blade %s ekeying is ok in position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.BladeTrapNoticeHandler"
DESCRIPTION "The server blade e-keying is ok.
This trap signifies that a server blade e-keying has returned to
normal operation.
User Action: None."
::= 22043
cpqRackNetConnectorRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Interconnect removed (22044)"
--#SUMMARY "Interconnect %s removed from position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Interconnect removed.
The interconnect has been removed from the enclosure.
User Action: None."
::= 22044
cpqRackNetConnectorInserted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Interconnect inserted (22045)"
--#SUMMARY "Interconnect %s inserted into position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "Interconnect inserted.
The interconnect has been inserted into the enclosure.
User Action: None."
::= 22045
cpqRackNetConnectorFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Interconnect failed (22046)"
--#SUMMARY "Interconnect %s failed in position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The interconnect status has been set to failed.
This trap signifies that a interconnect has failed.
User Action: Replace the interconnect as soon as possible."
::= 22046
cpqRackNetConnectorDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Interconnect degraded (22047)"
--#SUMMARY "Interconnect %s degraded in position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The interconnect status has been set to degraded.
This trap signifies that a interconnect has degraded.
User Action: Replace the interconnect as soon as possible."
::= 22047
cpqRackNetConnectorOk TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackNetConnectorEnclosureName, cpqRackNetConnectorName, cpqRackNetConnectorLocation, cpqRackNetConnectorSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Interconnect ok (22048)"
--#SUMMARY "Interconnect %s ok in position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Rack Net Connector Name: # $V7V#Connector Location: # $V8V#Connector Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.EnclosureTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
DESCRIPTION "The interconnect status has been set to ok.
This trap signifies that a interconnect has returned to
normal operation.
User Action: None."
::= 22048
cpqRackServerBladeToLowPower TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server Blade requested to low power (22049)"
--#SUMMARY "Server blade %s requested to low power in position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Trap Sequence Number: #"
DESCRIPTION "The server blade requested to low power.
User Action: None."
::= 22049
cpqRackServerBladeRemoved2 TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade removed (22050)"
--#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeRemovedTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Server Blade Serial Number: # $V11V#Server Blade Unique Id: # $V12V#Trap Sequence Number: #"
DESCRIPTION "Server blade removed. The server blade has been removed from the enclosure.
User Action: None."
::= 22050
cpqRackServerBladeInserted2 TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade inserted (22051)"
--#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#ENABLE true
--#CATEGORY "Proliant Rack Events"
--#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.BladeTrapRuleHandler"
--#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.EnclosureTrapNoticeHandler"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare Part Number: # $V9V#Enclosure Serial Number: # $V10V#Server Blade Serial Number: # $V11V#Server Blade Unique Id: # $V12V#Trap Sequence Number: #"
DESCRIPTION "Server blade inserted.
The server blade has been inserted into the enclosure.
User Action: None."
::= 22051
cpqRackServerBladeStatusRepaired TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladeProductId, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade repaired (22052)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s status has changed to OK."
--#ARGUMENTS {5, 7, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Product Id: # $V8V#Server Blade Position: # $V9V#Server Blade Spare PartNumber: # $V10V#Enclosure Serial Number: # $V11V#Server Blade Serial Number: # $V12V#Server Blade Id: # $V13V#Enclosure Trap Sequence Number: #"
DESCRIPTION "Server blade repaired.
The server blade status has changed to OK.
User Action: None."
::= 22052
cpqRackServerBladeStatusDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladeProductId, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeFaultMajor, cpqRackServerBladeFaultMinor, cpqRackServerBladeFaultDiagnosticString, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade health status degraded (22053)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s health status has changed to degraded. Reason: %s."
--#ARGUMENTS {5, 7, 4, 2, 14}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Product Id: # $V8V#Server Blade Position: # $V9V#Server Blade Spare PartNumber: # $V10V#Enclosure Serial Number: # $V11V#Server Blade Serial Number: # $V12V#Server Blade Id: # $V13V#Server Blade Fault Major: # $V14V#Server Blade Fault Minor: # $V15V#Blade Fault Diagnostic String: # $V16V#Enclosure Trap Sequence Number: #"
DESCRIPTION "Server blade health status Degraded.
The server blade health status has changed to Degraded.
User Action: Check blade server and enclosure SYSLOG."
::= 22053
cpqRackServerBladeStatusCritical TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladeProductId, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeFaultMajor, cpqRackServerBladeFaultMinor, cpqRackServerBladeFaultDiagnosticString, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade health status critical (22054)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s health status has changed to critical. Reason: %s."
--#ARGUMENTS {5, 7, 4, 2, 14}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Product Id: # $V8V#Server Blade Position: # $V9V#Server Blade Spare PartNumber: # $V10V#Enclosure Serial Number: # $V11V#Server Blade Serial Number: # $V12V#Server Blade Id: # $V13V#Server Blade Fault Major: # $V14V#Server Blade Fault Minor: # $V15V#Blade Fault Diagnostic String: # $V16V#Enclosure Trap Sequence Number: #"
DESCRIPTION "Server blade health status Critical.
The server blade health status has changed to Critical.
User Action: Check blade server and enclosure SYSLOG."
::= 22054
cpqRackServerBladeGrpCapTimeout TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade not responding to group capping requests (22055)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s is not responding to requests from the enclosure group capper."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE DEGRADED
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Enclosure Trap Sequence Number: #"
DESCRIPTION "The server blade is not responding to the group capper.
The server blade is not responding to capping requests from the enclosure group capper
User Action: Reset the iLO management processor."
::= 22055
cpqRackServerBladeUnexpectedShutdown TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade unexpected shutdown (22056)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has unexpectedly shutdown."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Enclosure Trap Number: #"
DESCRIPTION "Server blade shutdown unexpectadly.
An unexpected shutdown event has occurred for this server blade.
User Action: Check blade server and enclosure SYSLOG."
::= 22056
cpqRackServerBladeMangementControllerFirmwareUpdating TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeManagementDeviceFirmwareFlashingStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade management controller firmware update started (22057)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has started updating it's management controller firmware."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Firmware Flashing Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade's management controller firmware updating.
This server blade's management controller has started updating it's firmware.
User Action: None."
::= 22057
cpqRackServerBladeMangementControllerFirmwareUpdateComplete TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeManagementDeviceFirmwareFlashingStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade management controller firmware update completed (22058)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has finished updating it's management controller firmware."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Firmware Flashing Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade's management controller firmware update has completed.
This server blade's management controller has finished updating it's firmware.
User Action: None."
::= 22058
cpqRackServerBladeSystemBIOSFirmwareUpdating TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeSystemBIOSFlashingStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade system BIOS firmware update started (22059)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has started updating it's system BIOS firmware."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Firmware Flashing Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade's system BIOS firmware updating.
This server blade's system BIOS has started updating.
User Action: None."
::= 22059
cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeSystemBIOSFlashingStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade system BIOS firmware update completed (22060)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has completed updating it's system BIOS firmware."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Firmware Flashing Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade's system BIOS firmware update complete.
This server blade's system BIOS has completed updating.
User Action: None."
::= 22060
cpqRackServerBladeFrontIOBlankingActive TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeFrontIOBlankingModeStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade front IO blanking active (22061)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has disabled front IO."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Blade Front IO Blanking Mode Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade has disabled front IO ports.
Front IO blanking status has changed to active for this server blade.
User Action: None."
::= 22061
cpqRackServerBladeRemoteFrontIOBlankingInactive TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeFrontIOBlankingModeStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade front IO blanking inactive (22062)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has enabled front IO."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Blade Front IO Blanking Mode Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade has front IO blanking mode now inactive.
Front IO blanking status has changed to inactive for this server blade.
User Action: None."
::= 22062
cpqRackServerBladeDiagnosticAdaptorInserted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeDiagnosticAdaptorPresence, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade diagnostic adaptor inserted (22063)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s diagnostic adaptor inserted."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Server Blade Diagnostic Adaptor Presence: # $V13V#Trap Number: #"
DESCRIPTION "Server blade diagnostic adaptor inserted.
Blade diagnostic adaptor status has changed to inserted for this server blade.
User Action: None."
::= 22063
cpqRackServerBladeDiagnosticAdaptorRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladeDiagnosticAdaptorPresence, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade diagnostic adaptor removed (22064)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s diagnostic adaptor removed."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Server Blade Diagnostic Adaptor Presence: # $V13V#Trap Number: #"
DESCRIPTION "Server blade diagnostic adaptor removed.
Blade diagnostic adaptor status has changed to removed for this server blade.
User Action: None."
::= 22064
cpqRackServerBladeEnteredPXEBootMode TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePXEBootModeStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade has entered PXE Boot Mode (22065)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has entered PXE Boot Mode."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade PXE Boot Mode Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade has entered PXE Boot Mode.
Server blade Pre-Boot-eXecution (PXE) Mode started.
User Action: None."
::= 22065
cpqRackServerBladeExitedPXEBootMode TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePXEBootModeStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade has exited PXE Boot Mode (22066)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has exited PXE Boot Mode."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade PXE Boot Mode Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade has exited PXE Boot Mode.
Server blade Pre-Boot-eXecution (PXE) Mode exited.
User Action: None."
::= 22066
cpqRackServerBladeWarmReset TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePOSTStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade warm reset occurred (22067)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has been warm reset."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade POST Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade has been warm reset.
Server blade has experienced a warm reset.
User Action: None."
::= 22067
cpqRackServerBladePOSTCompleted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePOSTStatus, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade system BIOS POST completed (22068)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s system BIOS POST completed."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade POST Status: # $V13V#Trap Number: #"
DESCRIPTION "Server blade system BIOS POST complete.
Server blade has completed system BIOS Power-On-Self-Test (POST).
User Action: None."
::= 22068
cpqRackServerBladePoweredOn TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePowered, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade has powered on (22069)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has powered on."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade Powered: # $V13V#Trap Number: #"
DESCRIPTION "Server blade has powered on.
User Action: None."
::= 22069
cpqRackServerBladePoweredOff TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackServerBladeName, cpqRackServerBladePosition, cpqRackServerBladeSparePartNumber, cpqRackCommonEnclosureSerialNum, cpqRackServerBladeSerialNum, cpqRackServerBladeUid, cpqRackServerBladePowered, cpqRackCommonEnclosureTrapSequenceNum }
--#TYPE "Server blade has powered off (22070)"
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has powered off."
--#ARGUMENTS {5, 6, 4, 2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#CATEGORY "Proliant Rack Events"
--#MSG_FORMATTER "$V3V#Rack Name: # $V4V#Rack ID: # $V5V#Enclosure Name: # $V6V#Server Blade Name: # $V7V#Server Blade Position: # $V8V#Server Blade Spare PartNumber: # $V9V#Enclosure Serial Number: # $V10V#Blade Serial Number: # $V11V#Server blade ID: # $V12V#Rack Server Blade Powered: # $V13V#Trap Number: #"
DESCRIPTION "Server blade has powered off.
User Action: None."
::= 22070
cpqRackInformationalEAETrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
--#TYPE "Generic EAE Informational trap"
--#SUMMARY "%s"
--#ARGUMENTS {6}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
DESCRIPTION "EAE Informational trap"
::= 22071
cpqRackMinorEAETrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
--#TYPE "Generic EAE Minor trap"
--#SUMMARY "%s"
--#ARGUMENTS {6}
--#SEVERITY MINOR
--#TIMEINDEX 99
DESCRIPTION "EAE Minor trap"
::= 22072
cpqRackMajorEAETrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
--#TYPE "Generic EAE Major trap"
--#SUMMARY "%s"
--#ARGUMENTS {6}
--#SEVERITY MAJOR
--#TIMEINDEX 99
DESCRIPTION "EAE Major trap"
::= 22073
cpqRackCriticalEAETrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
--#TYPE "Generic EAE Critical trap"
--#SUMMARY "%s"
--#ARGUMENTS {6}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
DESCRIPTION "EAE Critical trap"
::= 22074
cpqRackPowerMinorEAETrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
--#TYPE "Generic Power Subsystem EAE Minor trap"
--#SUMMARY "%s"
--#ARGUMENTS {6}
--#SEVERITY MINOR
--#TIMEINDEX 99
DESCRIPTION "FlexFabric Cmdr Power Subsystem Minor trap.
User Action: For FlexFabric Cmdr, please refer to product documentation for
possible corrective actions."
::= 22075
cpqRackPowerMajorEAETrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
--#TYPE "Generic Power Subsystem EAE Major trap"
--#SUMMARY "%s"
--#ARGUMENTS {6}
--#SEVERITY MAJOR
--#TIMEINDEX 99
DESCRIPTION "FlexFabric Cmdr Power Subsystem Major trap.
User Action: For FlexFabric Cmdr, please refer to product documentation for
possible corrective actions."
::= 22076
cpqRackPowerCriticalEAETrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqRackName, cpqRackUid, cpqRackServerBladeEnclosureName, cpqRackCommonEnclosureTrapSequenceNum, cpqRackLastEAEEvent }
--#TYPE "Generic Power Subsystem EAE Critical trap"
--#SUMMARY "%s"
--#ARGUMENTS {6}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
DESCRIPTION "FlexFabric Cmdr Power Subsystem Critical trap.
User Action: For FlexFabric Cmdr, please refer to product documentation for
possible corrective actions."
::= 22077
END