snmp_mib_archive/cpqn5226a.cfg
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

1624 lines
43 KiB
INI
Executable File

#-MIBFILE: cpqn5226a.mib
CPQN5226A-MIB DEFINITIONS ::= BEGIN
DisplayString ::=
OCTET STRING
PhysAddress ::=
OCTET STRING
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
interfaces OBJECT IDENTIFIER ::= { mib-2 2 }
ifTable OBJECT IDENTIFIER ::= { interfaces 2 }
ifEntry OBJECT IDENTIFIER ::= { ifTable 1 }
ifIndex OBJECT IDENTIFIER ::= { ifEntry 1 }
CpqnRowStatus ::=
INTEGER {
row-valid(1),
row-invalid(2)
}
IpxAddress ::=
OCTET STRING (SIZE(10))
CpqnVersionType ::=
INTEGER {
other(1),
hardware(2),
software(3)
}
CpqnVersionStep ::=
INTEGER {
other(1),
engineering(2),
alpha(3),
beta(4),
prototype(5),
pilot(6),
pre-production(7),
production(8),
post-production(9),
simple-revision(10)
}
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
compaq-dallas-npd OBJECT IDENTIFIER ::= { compaq 101 }
switchedMedia OBJECT IDENTIFIER ::= { compaq-dallas-npd 2 }
cpqn52nn OBJECT IDENTIFIER ::= { switchedMedia 2 }
cpqn52nnOIDInfo OBJECT IDENTIFIER ::= { cpqn52nn 1 }
cpqn52nnModuleInfo OBJECT IDENTIFIER ::= { cpqn52nn 2 }
cpqn52nnMemoryInfo OBJECT IDENTIFIER ::= { cpqn52nn 3 }
cpqn52nnPortInfo OBJECT IDENTIFIER ::= { cpqn52nn 4 }
cpqn52nnIfStatusInfo OBJECT IDENTIFIER ::= { cpqn52nn 5 }
cpqn52nnIfStatsInfo OBJECT IDENTIFIER ::= { cpqn52nn 6 }
cpqn52nnSwitchStatsInfo OBJECT IDENTIFIER ::= { cpqn52nn 7 }
cpqn52nnBusMonitorInfo OBJECT IDENTIFIER ::= { cpqn52nn 8 }
cpqn52nnHashInfo OBJECT IDENTIFIER ::= { cpqn52nnMemoryInfo 1 }
cpqn52nnRmonMemory OBJECT IDENTIFIER ::= { cpqn52nnMemoryInfo 2 }
cpqn52nnMemoryThreshold OBJECT IDENTIFIER ::= { cpqn52nnMemoryInfo 3 }
cpqn52nnDramInfo OBJECT IDENTIFIER ::= { cpqn52nnMemoryInfo 4 }
cpqn52nnHashMemory OBJECT IDENTIFIER ::= { cpqn52nnSwitchStatsInfo 1 }
cpqn52nnDropPkts OBJECT IDENTIFIER ::= { cpqn52nnSwitchStatsInfo 2 }
cpqn52nnQuadCascade OBJECT IDENTIFIER ::= { cpqn52nnIfStatsInfo 1 }
cpqn52nnTlan OBJECT IDENTIFIER ::= { cpqn52nnIfStatsInfo 2 }
cpqn5226 OBJECT IDENTIFIER ::= { cpqn52nnOIDInfo 1 }
cpqn5226A OBJECT IDENTIFIER ::= { cpqn52nnOIDInfo 3 }
cpqn52nnVT100ScreenRefresh OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: This object will determine the rate, in seconds, at which
the VT100 screen will refresh the automatic fields (e.g., statistics).
The default value will be 5 seconds."
::= { cpqn52nnModuleInfo 1 }
cpqn52nnBooterWriteCycles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object will allow the user to see the number of erase/writes that
have been made to the Booter firmware sectors on the FLASH PROM chip."
::= { cpqn52nnModuleInfo 2 }
cpqn52nnRuntimeWriteCycles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object will allow the user to see the number of erase/writes that
have been made to the Runtime firmware sectors on the FLASH PROM chip."
::= { cpqn52nnModuleInfo 3 }
cpqn52nnSwitchModeType OBJECT-TYPE
SYNTAX INTEGER {
store-and-forward(1),
cut-through(2),
fragment-free(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: This object will determine the operational mode of
the switch. The default will be store-and-forward(1).
Fragment-free is not supported on 5226 nor 5226A."
::= { cpqn52nnModuleInfo 4 }
cpqn52nnCreateTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The minimum number of 5 minute intervals a table entry can have a status
of underCreate before the agent may delete the object. The default value
will be 1 5 minute interval."
::= { cpqn52nnModuleInfo 5 }
cpqn52nnPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnPowerSupplyEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A table of system power supply specific information."
::= { cpqn52nnModuleInfo 6 }
cpqn52nnPowerSupplyEntry OBJECT-TYPE
SYNTAX Cpqn52nnPowerSupplyEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "A list of information for every power supply installed"
INDEX { cpqn52nnPsIndex }
::= { cpqn52nnPowerSupplyTable 1 }
cpqn52nnPowerSupplyEntry ::=
SEQUENCE {
cpqn52nnPsIndex INTEGER,
cpqn52nnPsStatus INTEGER
}
cpqn52nnPsIndex OBJECT-TYPE
SYNTAX INTEGER {
power-supply-a(1),
power-supply-b(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each power supply."
::= { cpqn52nnPowerSupplyEntry 1 }
cpqn52nnPsStatus OBJECT-TYPE
SYNTAX INTEGER {
good(1),
bad(2),
not-present(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The status of the power supply. The value good(1) is returned if the
power supply identified by cpqn52nnPSIndex is running properly. The
value bad(2) is returned if the power supply identified by cpqn52nnPSIndex
has failed to operate properly but has been inserted into the slot. This
will include an inserted power supply with no power. The value na(3) is
returned if the power supply has not been inserted into the slot."
::= { cpqn52nnPowerSupplyEntry 2 }
cpqn52nnHashTableSize OBJECT-TYPE
SYNTAX INTEGER {
eight-K(1),
sixteen-K(2),
thirty-two-K(3),
sixty-four-K(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The number of address table entries, in 1024 increments,
allowed for the switch. NOTE that a smaller size table will increase
the likelihood of broadcasts based on unknown unicasts i.e. addresses
that have not been learned. The 5226 and 5226A allows set of 8K only."
::= { cpqn52nnHashInfo 1 }
cpqn52nnMaxMemory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Kbytes of memory that can be used for RMON. Actually this number does not
include some overhead needed to support the software. This number should be
set in the implementation of the agent to assure that memory is always
available for the overhead."
::= { cpqn52nnRmonMemory 1 }
cpqn52nnMemAllocFailure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The time of the last memory allocation failure that resulted from no
more physical memory available in the agent. This value is in seconds"
::= { cpqn52nnRmonMemory 2 }
cpqn52nnRmonMemoryCeiling OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Kbytes of memory RMON code may use, not counting any overhead."
::= { cpqn52nnRmonMemory 3 }
cpqn52nnStatisticsMemoryCeiling OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Kbytes of memory that the RMON statistics group may use."
::= { cpqn52nnRmonMemory 4 }
cpqn52nnHistoryMemoryCeiling OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Kbytes of memory that the RMON history group may use."
::= { cpqn52nnRmonMemory 5 }
cpqn52nnAlarmMemoryCeiling OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Kbytes of memory that the RMON alarm group may use."
::= { cpqn52nnRmonMemory 6 }
cpqn52nnEventMemoryCeiling OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Kbytes of memory that the RMON event group may use."
::= { cpqn52nnRmonMemory 7 }
cpqn52nnRmonMemoryUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Kbytes of memory used by RMON, rounded up."
::= { cpqn52nnRmonMemory 8 }
cpqn52nnStatisticsMemoryUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Kbytes of memory that the RMON statistics group has used."
::= { cpqn52nnRmonMemory 9 }
cpqn52nnHistoryMemoryUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Kbytes of memory that the RMON history group has used."
::= { cpqn52nnRmonMemory 10 }
cpqn52nnAlarmMemoryUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Kbytes of memory that the RMON alarm group has used."
::= { cpqn52nnRmonMemory 11 }
cpqn52nnEventMemoryUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Kbytes of memory that the RMON event group has used."
::= { cpqn52nnRmonMemory 12 }
cpqn52nnMaxPktMemory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Kbytes of memory that can be used for Packet Memory."
::= { cpqn52nnMemoryThreshold 1 }
cpqn52nnGlobalMemThreshTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Enable Traps for all thresholding entries in the Global Memory
group of objects. The default value is disabled."
::= { cpqn52nnMemoryThreshold 2 }
cpqn52nnBcastMemThreshEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Enable thresholding for the Broadcast packet count. The default
value is disabled."
::= { cpqn52nnMemoryThreshold 3 }
cpqn52nnBcastPktCeiling OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Value in 256 packet increments of the falling threshold of
the maximum number of broadcast packets allowed in packet buffer memory."
::= { cpqn52nnMemoryThreshold 4 }
cpqn52nnBcastHysteresisCtl OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Number of packets that when added to the Bcast packet ceiling
produces the Rising Threshold value of the maximum number of broadcast
packets allowed in packet buffer memory."
::= { cpqn52nnMemoryThreshold 5 }
cpqn52nnBcastPktCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicator of many broadcast packets are actually in packet buffer memory."
::= { cpqn52nnMemoryThreshold 6 }
cpqn52nnBcastCongestionStatus OBJECT-TYPE
SYNTAX INTEGER {
congested(1),
not-congested(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicator of broadcast packet congestion. When congested, the number of
broadcast packets in packet buffer memory has exceeded the rising threshold,
but has not gone below the falling threshold."
::= { cpqn52nnMemoryThreshold 7 }
cpqn52nnPortMemThreshTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnPortMemThreshEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table defines something."
::= { cpqn52nnMemoryThreshold 8 }
cpqn52nnPortMemThreshEntry OBJECT-TYPE
SYNTAX Cpqn52nnPortMemThreshEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table has one entry for each port. The index
into the table is cpqn52nnPortThreshIfIndex."
INDEX { cpqn52nnPortThreshIfIndex }
::= { cpqn52nnPortMemThreshTable 1 }
cpqn52nnPortMemThreshEntry ::=
SEQUENCE {
cpqn52nnPortThreshIfIndex INTEGER,
cpqn52nnPortTxPktThreshEnable INTEGER,
cpqn52nnPortTxPktCongestionStatus INTEGER,
cpqn52nnPortTxPktCnt INTEGER,
cpqn52nnPortTxPktCeiling INTEGER,
cpqn52nnPortTxPktHysteresisCtl INTEGER,
cpqn52nnPortRxMemThreshEnable INTEGER,
cpqn52nnPortRxMemCongestionStatus INTEGER,
cpqn52nnPortRxMemSectorCnt INTEGER,
cpqn52nnPortRxMemCeiling INTEGER,
cpqn52nnPortRxMemHysteresisCtl INTEGER,
cpqn52nnPortCongestionTrapEnable INTEGER
}
cpqn52nnPortThreshIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Interface Index as represented in MIB-II."
::= { cpqn52nnPortMemThreshEntry 1 }
cpqn52nnPortTxPktThreshEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Enables or disabled transmit packet thresholding on a
per port basis."
::= { cpqn52nnPortMemThreshEntry 2 }
cpqn52nnPortTxPktCongestionStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicator of port transmit packet congestion. When congested, the number of
transmit packets in packet buffer memory for the port has exceeded the rising
threshold, but has not gone below the falling threshold."
::= { cpqn52nnPortMemThreshEntry 3 }
cpqn52nnPortTxPktCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicator of how many transmit packets for the port are actually in packet
buffer memory."
::= { cpqn52nnPortMemThreshEntry 4 }
cpqn52nnPortTxPktCeiling OBJECT-TYPE
SYNTAX INTEGER (0..4096)
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Value in 256 packet increments of the falling threshold of
the maximum number of transmit packets allowed for the port in packet
buffer memory."
::= { cpqn52nnPortMemThreshEntry 5 }
cpqn52nnPortTxPktHysteresisCtl OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Number of packets that when added to the port's transmit packet
ceiling produces the Rising Threshold value of the maximum number of transmit
packets allowed for the port in packet buffer memory."
::= { cpqn52nnPortMemThreshEntry 6 }
cpqn52nnPortRxMemThreshEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Enables or disables receive memory thresholding on a
per port basis."
::= { cpqn52nnPortMemThreshEntry 7 }
cpqn52nnPortRxMemCongestionStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicator of port receive memory congestion. When congested, the amount of
receive packet buffer memory used by the port has exceeded the rising
threshold, but has not gone below the falling threshold."
::= { cpqn52nnPortMemThreshEntry 8 }
cpqn52nnPortRxMemSectorCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicator of how amount Packet Receive memory, in 2Kbyte increments, is
actually being used by the port."
::= { cpqn52nnPortMemThreshEntry 9 }
cpqn52nnPortRxMemCeiling OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Value in 32Kbyte increments of the falling threshold of
the maximum receive packet memory allowed for the port in packet
buffer memory."
::= { cpqn52nnPortMemThreshEntry 10 }
cpqn52nnPortRxMemHysteresisCtl OBJECT-TYPE
SYNTAX INTEGER (1..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Value in 2Kbyte increments that when added to the port's
receive memory ceiling produces the Rising Threshold value of the
maximum receive memory allowed for the port in packet buffer memory."
::= { cpqn52nnPortMemThreshEntry 11 }
cpqn52nnPortCongestionTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Enables or disabled traps due to congestion states for any Port."
::= { cpqn52nnPortMemThreshEntry 12 }
cpqn52nnDramTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnDramEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table defines the unit's Dram information."
::= { cpqn52nnDramInfo 1 }
cpqn52nnDramEntry OBJECT-TYPE
SYNTAX Cpqn52nnDramEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table has one entry for each Dram component. The index
into the table is cpqn52nnDramIndex."
INDEX { cpqn52nnDramIndex }
::= { cpqn52nnDramTable 1 }
cpqn52nnDramEntry ::=
SEQUENCE {
cpqn52nnDramIndex INTEGER,
cpqn52nnDramSize INTEGER,
cpqn52nnDramType INTEGER,
cpqn52nnDramSpeed INTEGER
}
cpqn52nnDramIndex OBJECT-TYPE
SYNTAX INTEGER {
packet-buffers(1),
cpu-dram(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "A simple index representing the area using the DRAM."
::= { cpqn52nnDramEntry 1 }
cpqn52nnDramSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Size of DRAM being used, in KBytes."
::= { cpqn52nnDramEntry 2 }
cpqn52nnDramType OBJECT-TYPE
SYNTAX INTEGER {
fastpage-mode(1),
edo(2),
synchronous(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Type of DRAM being used."
::= { cpqn52nnDramEntry 3 }
cpqn52nnDramSpeed OBJECT-TYPE
SYNTAX INTEGER {
dram-70ns(1),
dram-60ns(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Speed of DRAM being used."
::= { cpqn52nnDramEntry 4 }
cpqn52nnPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnPortStatusEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table defines certain Port Level parameters for each port."
::= { cpqn52nnPortInfo 1 }
cpqn52nnPortStatusEntry OBJECT-TYPE
SYNTAX Cpqn52nnPortStatusEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table has one entry for each port. The index
into the table is cpqn52nnPortStatusId."
INDEX { cpqn52nnPortIfIndex , cpqn52nnPortIfMauIndex }
::= { cpqn52nnPortStatusTable 1 }
cpqn52nnPortStatusEntry ::=
SEQUENCE {
cpqn52nnPortIfIndex INTEGER,
cpqn52nnPortIfMauIndex INTEGER,
cpqn52nnPortName DisplayString,
cpqn52nnPortType INTEGER,
cpqn52nnMdiMdixStatus INTEGER,
cpqn52nnMdiMdixEnable INTEGER
}
cpqn52nnPortIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Switch interface number that corresponds to the interface in MIB-II."
::= { cpqn52nnPortStatusEntry 1 }
cpqn52nnPortIfMauIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Uniquely identifies the port in the CPQN52nn unit for which
additional info is being obtained."
::= { cpqn52nnPortStatusEntry 2 }
cpqn52nnPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: User defined name for port."
::= { cpqn52nnPortStatusEntry 3 }
cpqn52nnPortType OBJECT-TYPE
SYNTAX INTEGER {
empty(1),
eth-10-baseT(2),
tx(3),
fxsc(4),
fxst(5),
eth-10-100(6),
fddi-das(7),
fddi-sas(8),
fddi-sas-tp-pmd(9),
atm(10),
unknown(1000)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object identifies all possible port types. Note that unknown
Port Types are represented by the value 1000."
::= { cpqn52nnPortStatusEntry 4 }
cpqn52nnMdiMdixStatus OBJECT-TYPE
SYNTAX INTEGER {
mdi(1),
mdi-x(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object identifies all possible port types."
::= { cpqn52nnPortStatusEntry 5 }
cpqn52nnMdiMdixEnable OBJECT-TYPE
SYNTAX INTEGER {
mdi(1),
mdi-x(2),
auto-sensing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object identifies all possible port types."
::= { cpqn52nnPortStatusEntry 6 }
cpqn52nnPortMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnPortMonitorEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table defines monitor information."
::= { cpqn52nnPortInfo 2 }
cpqn52nnPortMonitorEntry OBJECT-TYPE
SYNTAX Cpqn52nnPortMonitorEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table can be empty. Entries can be added as needed. The index
into the table is cpqn52nnPortMonitorIndex."
INDEX { cpqn52nnPortMonitorIndex }
::= { cpqn52nnPortMonitorTable 1 }
cpqn52nnPortMonitorEntry ::=
SEQUENCE {
cpqn52nnPortMonitorIndex INTEGER,
cpqn52nnPortMonitorRowStatus CpqnRowStatus,
cpqn52nnPortMonitorIfIndex INTEGER,
cpqn52nnPortMonitoredIfMap INTEGER,
cpqn52nnPortMonitoredDataType INTEGER
}
cpqn52nnPortMonitorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A simple index represnting the number of the entry being examined."
::= { cpqn52nnPortMonitorEntry 1 }
cpqn52nnPortMonitorRowStatus OBJECT-TYPE
SYNTAX CpqnRowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The status of this row entry. Rows are added to this table
using 'row sets'. When a row is added, this object must be set to
row-valid(1). To delete a row from this table, set this object for the
row to row-invalid(2). This object will always read as row-valid(1)."
::= { cpqn52nnPortMonitorEntry 2 }
cpqn52nnPortMonitorIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE An index based on the interface index in MIB-II. This will
represent the interface to be used to monitor the data of others as
defined by cpqn52nnPortMonitoredIfMap."
::= { cpqn52nnPortMonitorEntry 3 }
cpqn52nnPortMonitoredIfMap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: A bitmap indicating the ports whose data is being monitored.
The bits used to represent the are the same as the IfIndex representation
of the ports. e.g. port 25 --> 25th bit. An example is 0x00000003,
indicates that ports 1 and 3 are being monitored. The port doing the
monitoring is defined by cpqn52nnPortMonitorIfIndex for this row in the
table."
::= { cpqn52nnPortMonitorEntry 4 }
cpqn52nnPortMonitoredDataType OBJECT-TYPE
SYNTAX INTEGER {
tx-only(1),
rx-only(2),
both-tx-and-rx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The type of data to be monitored by the monitor port.
Selecting TX or RX means that only the TX or RX data will be monitored
by the monitor port."
::= { cpqn52nnPortMonitorEntry 5 }
cpqn52nnPortBondingTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnPortBondingEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table defines uplink bonding information."
::= { cpqn52nnPortInfo 3 }
cpqn52nnPortBondingEntry OBJECT-TYPE
SYNTAX Cpqn52nnPortBondingEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "The index into the table is cpqn52nnBondIndex. The table can be empty."
INDEX { cpqn52nnBondIndex }
::= { cpqn52nnPortBondingTable 1 }
cpqn52nnPortBondingEntry ::=
SEQUENCE {
cpqn52nnBondIndex INTEGER,
cpqn52nnBondRowStatus CpqnRowStatus,
cpqn52nnBondMap INTEGER
}
cpqn52nnBondIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A simple index representing the entry number."
::= { cpqn52nnPortBondingEntry 1 }
cpqn52nnBondRowStatus OBJECT-TYPE
SYNTAX CpqnRowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The status of this row entry. Rows are added to this table
using 'row sets'. When a row is added, this object must be set to
row-valid(1). To delete a row from this table, set this object for the
row to row-invalid(2). This object will always read as row-valid(1)."
::= { cpqn52nnPortBondingEntry 2 }
cpqn52nnBondMap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: A bitmap indicating the uplink ports that are bonded together.
The bits used to represent the uplink ports are the same as the If Index
representations of the ports. e.g. port 25 --> 25th bit. An example is
0x05000000, indicates that uplink ports 25 and 27 are bonded."
::= { cpqn52nnPortBondingEntry 3 }
cpqn52nnIfStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnIfStatusEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table defines certain switch interface level parameters for each
interface."
::= { cpqn52nnIfStatusInfo 1 }
cpqn52nnIfStatusEntry OBJECT-TYPE
SYNTAX Cpqn52nnIfStatusEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table has one entry for each switch interface. The index
into the table is cpqn52nnIfStatusIfIndex."
INDEX { cpqn52nnIfStatusIfIndex }
::= { cpqn52nnIfStatusTable 1 }
cpqn52nnIfStatusEntry ::=
SEQUENCE {
cpqn52nnIfStatusIfIndex INTEGER,
cpqn52nnIfStatusIfType INTEGER,
cpqn52nnIfStpStatus INTEGER,
cpqn52nnIfResetStatus INTEGER,
cpqn52nnIfLearningStatus INTEGER,
cpqn52nnIfAgingStatus INTEGER,
cpqn52nnIfAgingTime INTEGER,
cpqn52nnIfSwitchModeSrcStatus INTEGER,
cpqn52nnIfSwitchModeDestStatus INTEGER,
cpqn52nnIfSwitchModeSrc INTEGER,
cpqn52nnIfSwitchModeDest INTEGER,
cpqn52nnIfArbPriority INTEGER
}
cpqn52nnIfStatusIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The value of the instance of the ifIndex object,
defined in MIB-II, for this switch interface. "
::= { cpqn52nnIfStatusEntry 1 }
cpqn52nnIfStatusIfType OBJECT-TYPE
SYNTAX INTEGER {
quad-cascade-lsi-l64381(1),
tlan-ti-tnete110(2),
qe110-lsi(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of device used for this switch interface."
::= { cpqn52nnIfStatusEntry 2 }
cpqn52nnIfStpStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "When enabled(1), this interface will participate in
Spanning Tree activities. When disabled(2), this interface
will not participate in the Spanning Tree algorithm.
Default is enabled(1). DURABLE."
::= { cpqn52nnIfStatusEntry 3 }
cpqn52nnIfResetStatus OBJECT-TYPE
SYNTAX INTEGER {
interface-not-resetting(1),
reset-interface(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object will allow the user to physically reset an interface on
the CPQN52nn. The advantage over a general reset is that the other
interfaces are left unaffected in their operation. The agent will
always return interface-not-resetting(1) when the object is read."
::= { cpqn52nnIfStatusEntry 4 }
cpqn52nnIfLearningStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "When enabled(1), this interface can enter the learning
state. When disabled(2), this interface is not allowed to
enter the learning state. When disabled(2), Spanning Tree
must be set to disabled. Default is enabled(1). DURABLE."
::= { cpqn52nnIfStatusEntry 5 }
cpqn52nnIfAgingStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "When enabled(1), this interface ages learned entries in the
Address Filter/Forward table. When disabled(2), this interface
does not age entries in the address table.
Default is enabled(1). DURABLE."
::= { cpqn52nnIfStatusEntry 6 }
cpqn52nnIfAgingTime OBJECT-TYPE
SYNTAX INTEGER (10..1000000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The timeout period in seconds for aging out dynamically
learned forwarding information on the switch interface.
DURABLE"
::= { cpqn52nnIfStatusEntry 7 }
cpqn52nnIfSwitchModeSrcStatus OBJECT-TYPE
SYNTAX INTEGER {
store-and-forward(1),
cut-through(2),
fragment-free(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The switch mode for this interface when it is the Source
in a switch transfer."
::= { cpqn52nnIfStatusEntry 8 }
cpqn52nnIfSwitchModeDestStatus OBJECT-TYPE
SYNTAX INTEGER {
store-and-forward(1),
cut-through(2),
fragment-free(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The switch mode for this interface when it is the Destination
in a switch transfer."
::= { cpqn52nnIfStatusEntry 9 }
cpqn52nnIfSwitchModeSrc OBJECT-TYPE
SYNTAX INTEGER {
store-and-forward(1),
cut-through(2),
fragment-free(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The switch mode for this interface when it is the Source
in a switch transfer. The default case is store-and-forward(1)."
::= { cpqn52nnIfStatusEntry 10 }
cpqn52nnIfSwitchModeDest OBJECT-TYPE
SYNTAX INTEGER {
store-and-forward(1),
cut-through(2),
fragment-free(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The switch mode for this interface when it is the Destination
in a switch transfer. The default case is store-and-forward(1)."
::= { cpqn52nnIfStatusEntry 11 }
cpqn52nnIfArbPriority OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The priority mechanism used for arbitration. The possible
arbitration states and values are as follows:
VALUE ARBITRATION
----- -----------
0 First-Come-First-Served
all port same Round Robin (Fair)
all ports varied Round Robin (Weighted)
The final case implies that not all ports have the same priority in which
case a weighted Round Robin method of arbitration would be used. The default
case has all ports with a value of 0 (First-Come-First-Served)."
::= { cpqn52nnIfStatusEntry 12 }
cpqn52nnQuadIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnQuadIfEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table provides information, on a per port basis, for the Quad
Cascade devices."
::= { cpqn52nnQuadCascade 1 }
cpqn52nnQuadIfEntry OBJECT-TYPE
SYNTAX Cpqn52nnQuadIfEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table has one entry for each Port. The indices
into the table are cpqn52nnQuadIfIndex."
INDEX { cpqn52nnQuadIfIndex }
::= { cpqn52nnQuadIfTable 1 }
cpqn52nnQuadIfEntry ::=
SEQUENCE {
cpqn52nnQuadIfIndex INTEGER,
cpqn52nnQuadIfAlignFcsErrors Counter,
cpqn52nnQuadIfTxRunts Counter,
cpqn52nnQuadIfRxRunts Counter,
cpqn52nnQuadIfTotalCollisions Counter
}
cpqn52nnQuadIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "An index representing the interface as in MIN-II."
::= { cpqn52nnQuadIfEntry 1 }
cpqn52nnQuadIfAlignFcsErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the number of packets received between 64 and 1518 bytes in
length, but were not an integral number of bytes in length, or had
a bad Frame Check Sequence."
::= { cpqn52nnQuadIfEntry 2 }
cpqn52nnQuadIfTxRunts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the number of packets transmitted that were less than 64 bytes
in length."
::= { cpqn52nnQuadIfEntry 3 }
cpqn52nnQuadIfRxRunts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the number of packets received that were less than 64 bytes
long that were an integral number of bytes long."
::= { cpqn52nnQuadIfEntry 4 }
cpqn52nnQuadIfTotalCollisions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the number of collision packets, single and multiple."
::= { cpqn52nnQuadIfEntry 5 }
cpqn52nnQuadIfCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnQuadIfCfgEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table provides information, on a per port basis, for the Quad
Cascade devices."
::= { cpqn52nnQuadCascade 2 }
cpqn52nnQuadIfCfgEntry OBJECT-TYPE
SYNTAX Cpqn52nnQuadIfCfgEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table has one entry for each Port. The index
into the table is cpqn52nnQuadIfIndex."
INDEX { cpqn52nnQuadIfCfgIndex , cpqn52nnQuadIfCfgMauIndex }
::= { cpqn52nnQuadIfCfgTable 1 }
cpqn52nnQuadIfCfgEntry ::=
SEQUENCE {
cpqn52nnQuadIfCfgIndex INTEGER,
cpqn52nnQuadIfCfgMauIndex INTEGER,
cpqn52nnQuadIfCfgLinkForce INTEGER,
cpqn52nnQuadIfCfgLinkPolarityCorrect INTEGER
}
cpqn52nnQuadIfCfgIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "An index representing the interface as in MIN-II."
::= { cpqn52nnQuadIfCfgEntry 1 }
cpqn52nnQuadIfCfgMauIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { cpqn52nnQuadIfCfgEntry 2 }
cpqn52nnQuadIfCfgLinkForce OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: When enabled, this object allows the port to transmit
even if link integrity fails."
::= { cpqn52nnQuadIfCfgEntry 3 }
cpqn52nnQuadIfCfgLinkPolarityCorrect OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: When enabled, this allows the port to correct for inverted
polarity on the twisted pair interface, if an inverted polarity
condition exists on that port."
::= { cpqn52nnQuadIfCfgEntry 4 }
cpqn52nnTlanIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnTlanIfEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table provides information, on a per port basis, for the Tlan
devices."
::= { cpqn52nnTlan 1 }
cpqn52nnTlanIfEntry OBJECT-TYPE
SYNTAX Cpqn52nnTlanIfEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table has one entry for each Port. The index
into the table is cpqn52nnTlanIfIndex."
INDEX { cpqn52nnTlanIfIndex }
::= { cpqn52nnTlanIfTable 1 }
cpqn52nnTlanIfEntry ::=
SEQUENCE {
cpqn52nnTlanIfIndex INTEGER,
cpqn52nnTlanIfTxGoodFrms Counter,
cpqn52nnTlanIfRxUndersizeFrms Counter,
cpqn52nnTlanIfRxOverruns Counter,
cpqn52nnTlanIfRxAlignSymbolErrs Counter
}
cpqn52nnTlanIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A simple index representing the Port in the table representing the
IfIndex in MIB-II."
::= { cpqn52nnTlanIfEntry 1 }
cpqn52nnTlanIfTxGoodFrms OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the number of packets transmitted that were good (no errors)."
::= { cpqn52nnTlanIfEntry 2 }
cpqn52nnTlanIfRxUndersizeFrms OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the number of packets that were "
::= { cpqn52nnTlanIfEntry 3 }
cpqn52nnTlanIfRxOverruns OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the number of packets received that were "
::= { cpqn52nnTlanIfEntry 4 }
cpqn52nnTlanIfRxAlignSymbolErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the number of packets received that had either Alignment errors
or Symbol errors."
::= { cpqn52nnTlanIfEntry 5 }
cpqn52nnHashStaticNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A count of static entries in this switch interface's
Address Forwarding/Filtering mechanism."
::= { cpqn52nnHashMemory 1 }
cpqn52nnHashDynamicNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A count of dynamic entries in this switch interface's
Address Forwarding/Filtering mechanism."
::= { cpqn52nnHashMemory 2 }
cpqn52nnHashChainNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A count of indices in the Address Filter/Forward
mechanism's hash table which have more than one
MAC Address entry."
::= { cpqn52nnHashMemory 3 }
cpqn52nnHashChainLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A count of the number of MAC Address entries
in the longest chain in the Address Filter/Forward
mechanism's hash table."
::= { cpqn52nnHashMemory 4 }
cpqn52nnDropsWholeMemoryCtr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Counter to indicate the total number of packets dropped due to memory
overflow. This is exclusive of the other counters in this section."
::= { cpqn52nnDropPkts 1 }
cpqn52nnDropsBcastMemoryCtr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Counter to indicate the total number of packets dropped due to memory
overflow in the area handling Broadcast packets only. This is exclusive
of the other counters in this section."
::= { cpqn52nnDropPkts 2 }
cpqn52nnDropsIfMemoryCtr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Counter to indicate the total number of packets dropped due to memory
overflow in the area handling interface TX/RX packets only. This is
exclusive of the other counters in this section."
::= { cpqn52nnDropPkts 3 }
cpqn52nnBusMonTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cpqn52nnBusMonEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table defines the unit's utilization information."
::= { cpqn52nnBusMonitorInfo 1 }
cpqn52nnBusMonEntry OBJECT-TYPE
SYNTAX Cpqn52nnBusMonEntry
ACCESS read-only
STATUS mandatory
DESCRIPTION "This table has one entry for each bus component. The index
into the table is cpqn52nnBusMonIndex."
INDEX { cpqn52nnBusMonIndex }
::= { cpqn52nnBusMonTable 1 }
cpqn52nnBusMonEntry ::=
SEQUENCE {
cpqn52nnBusMonIndex INTEGER,
cpqn52nnBusMonRowStatus CpqnRowStatus,
cpqn52nnBusMonBusType INTEGER,
cpqn52nnBusMonDataType INTEGER,
cpqn52nnBusMonPktType INTEGER,
cpqn52nnBusMonSwitchModeType INTEGER,
cpqn52nnBusMonCurrentUtilization INTEGER,
cpqn52nnBusMonPeakUtilization INTEGER,
cpqn52nnBusMonRisingThreshold INTEGER,
cpqn52nnBusMonFallingThreshold INTEGER,
cpqn52nnBusMonAction INTEGER,
cpqn52nnBusMonTrapEnable INTEGER
}
cpqn52nnBusMonIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A simple index representing the entry in the table."
::= { cpqn52nnBusMonEntry 1 }
cpqn52nnBusMonRowStatus OBJECT-TYPE
SYNTAX CpqnRowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The status of this alarm entry."
::= { cpqn52nnBusMonEntry 2 }
cpqn52nnBusMonBusType OBJECT-TYPE
SYNTAX INTEGER {
mac-bus(1),
mem-bus(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The type of bus to be monitored."
::= { cpqn52nnBusMonEntry 3 }
cpqn52nnBusMonDataType OBJECT-TYPE
SYNTAX INTEGER {
tx-only(1),
rx-only(2),
both-tx-and-rx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The type of data to be monitored."
::= { cpqn52nnBusMonEntry 4 }
cpqn52nnBusMonPktType OBJECT-TYPE
SYNTAX INTEGER {
pkt-data-only(1),
pkt-overhead-only(2),
both-data-and-overhead(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The type of data to be monitored."
::= { cpqn52nnBusMonEntry 5 }
cpqn52nnBusMonSwitchModeType OBJECT-TYPE
SYNTAX INTEGER {
store-and-forward-only(1),
cut-through-only(2),
both-switch-modes(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: The type of packets monitored for data."
::= { cpqn52nnBusMonEntry 6 }
cpqn52nnBusMonCurrentUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Utilization of the selected port calculated as a percentage of
the total bandwidth available for the bus."
::= { cpqn52nnBusMonEntry 7 }
cpqn52nnBusMonPeakUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Utilization of the selected port calculated as a percentage of
the total bandwidth available for the bus."
::= { cpqn52nnBusMonEntry 8 }
cpqn52nnBusMonRisingThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: If this threshold is exceeded, then the action listed in
ThresholdAction will take place. The value is a % utilzation."
::= { cpqn52nnBusMonEntry 9 }
cpqn52nnBusMonFallingThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: If this threshold is exceeded, then the action listed in
ThresholdAction will take place. The value is a % utilzation."
::= { cpqn52nnBusMonEntry 10 }
cpqn52nnBusMonAction OBJECT-TYPE
SYNTAX INTEGER {
filter(1),
backpressure(2),
filter-broadcast(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: If this threshold is exceeded, then the action listed in
ThresholdAction will take place. The value is an absolute number in
bytes/sec."
::= { cpqn52nnBusMonEntry 11 }
cpqn52nnBusMonTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "DURABLE: Enable Trap Generation if threshold is exceeded."
::= { cpqn52nnBusMonEntry 12 }
cpqn52nnPowerSupplyStatusTrap TRAP-TYPE
ENTERPRISE cpqn52nn
VARIABLES { cpqn52nnPsIndex, cpqn52nnPsStatus }
--#TYPE "PowerSupplyStatusTrap"
--#SUMMARY "PowerSupplyStatusTrap"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY "Giga Switch Events"
--#TIMEINDEX 99
DESCRIPTION "A cpqn52nnPowerSupplyStatus Trap is sent whenever a power supply
changes state from voltage-ok to voltage-not-ok or vice versa."
::= 1
cpqn52nnUplinkInsertedTrap TRAP-TYPE
ENTERPRISE cpqn52nn
VARIABLES { ifIndex, cpqn52nnPortType }
--#TYPE "UplinkInserted"
--#SUMMARY "UplinkInserted"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY "Giga Switch Events"
--#TIMEINDEX 99
DESCRIPTION "The cpqn52nnMepInserted trap is sent whenever a MEP, that
represents a physical interface, is added."
::= 2
cpqn52nnUplinkRemovedTrap TRAP-TYPE
ENTERPRISE cpqn52nn
VARIABLES { ifIndex, cpqn52nnPortType }
--#TYPE "UplinkRemoved"
--#SUMMARY "UplinkRemoved"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY "Giga Switch Events"
--#TIMEINDEX 99
DESCRIPTION "The cpqn52nnMepRemoved trap is sent whenever a MEP, that
represents a physical interface, is removed."
::= 3
cpqn52nnBusMonRisingThresholdTrap TRAP-TYPE
ENTERPRISE cpqn52nn
VARIABLES { cpqn52nnBusMonIndex, cpqn52nnBusMonBusType, cpqn52nnBusMonCurrentUtilization }
--#TYPE "BusMonRisongThresholdTrap"
--#SUMMARY "BusMonRisingThresholdTrap"
--#ARGUMENTS {3}
--#SEVERITY MAJOR
--#CATEGORY "Giga Switch Events"
--#TIMEINDEX 99
DESCRIPTION "The SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates
an event that is configured for sending SNMP
traps."
::= 4
cpqn52nnBusMonFallingThresholdTrap TRAP-TYPE
ENTERPRISE cpqn52nn
VARIABLES { cpqn52nnBusMonIndex, cpqn52nnBusMonBusType, cpqn52nnBusMonCurrentUtilization }
--#TYPE "BusMonFallingThresholdTrap"
--#SUMMARY "BusMonFallingThresholdTrap"
--#ARGUMENTS {3}
--#SEVERITY MAJOR
--#CATEGORY "Giga Switch Events"
--#TIMEINDEX 99
DESCRIPTION "The SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates
an event that is configured for sending SNMP
traps."
::= 5
cpqb52nnGlobalBcastMemCongestionTrap TRAP-TYPE
ENTERPRISE cpqn52nn
VARIABLES { cpqn52nnBcastCongestionStatus }
--#TYPE "GlobalBcastMemCongestionTrap"
--#SUMMARY "GlobalBcastMemCongestionTrap"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY "Giga Switch Events"
--#TIMEINDEX 99
DESCRIPTION "The SNMP trap that is generated when an alarm
entry crosses its rising or falling threshold and
generates an event that is configured for sending
SNMP traps."
::= 7
cpqb52nnPortTxPktCongestionTrap TRAP-TYPE
ENTERPRISE cpqn52nn
VARIABLES { cpqn52nnPortThreshIfIndex, cpqn52nnPortTxPktCongestionStatus }
--#TYPE "PortTxPktCongestionTrap"
--#SUMMARY "PortTxxPktCongestionTrap"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY "Giga Switch Events"
--#TIMEINDEX 99
DESCRIPTION "The SNMP trap that is generated when an alarm
entry crosses its rising or falling threshold and
generates an event that is configured for sending
SNMP traps."
::= 8
cpqb52nnPortRxMemCongestionTrap TRAP-TYPE
ENTERPRISE cpqn52nn
VARIABLES { cpqn52nnPortThreshIfIndex, cpqn52nnPortRxMemCongestionStatus }
--#TYPE "PortRxMemCongestionTrap"
--#SUMMARY "PortRxMemCongestionTrap"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY "Giga Switch Events"
--#TIMEINDEX 99
DESCRIPTION "The SNMP trap that is generated when an alarm
entry crosses its rising or falling threshold and
generates an event that is configured for sending
SNMP traps."
::= 9