snmp_mib_archive/cpq54nn.mib
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

245 lines
8.6 KiB
Plaintext
Executable File

-- * Revision 1.2 1997/12/20 03:06:32 asmith
CPQN54NN-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
sysUpTime, sysDescr FROM RFC1213-MIB
TRAP-TYPE FROM RFC-1215
OBJECT-TYPE FROM RFC-1212;
-- Organization & Product branches
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
--
-- Compaq Products
--
cpqGigaSwitch OBJECT IDENTIFIER ::= { compaq 111}
cpqGigaSwitchProd OBJECT IDENTIFIER ::= { cpqGigaSwitch 1}
cpqGigaSwitchId5422 OBJECT IDENTIFIER ::= { cpqGigaSwitchProd 1}
cpqGigaSwitchId5411 OBJECT IDENTIFIER ::= { cpqGigaSwitchProd 2}
--
-- MIB Objects
--
cpqGigaSwitchMib OBJECT IDENTIFIER ::= { cpqGigaSwitch 3 }
--
-- System group
--
cpqGigaSwitchSystem OBJECT IDENTIFIER ::= { cpqGigaSwitchMib 1 }
-- Configuration save objects. These objects are used by the network
-- management application to save configuration changes into the
-- persistant store. There are 2 stores on the device; a primary and
-- a secondary.
cpqSaveConfiguration OBJECT-TYPE
SYNTAX INTEGER {
saveToPrimary(1),
saveToSecondary(2)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"When this object is set, the device will copy the contents
of the configuration database to a buffer and save it to the
persistant store specified by the value of the object. The
save is performed asynchronously, and the snmp agent will continue
to respond to both gets and sets while the save is taking
place. A network management application may use the
cpqSaveStatus object to determine when the asynchronous
save operation has completed."
::= { cpqGigaSwitchSystem 3 }
cpqSaveStatus OBJECT-TYPE
SYNTAX INTEGER {
saveInProgress(1),
saveNotInProgress(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object will return the status of a save operation invoked
by setting the cpqSaveConfiguration object. A network
management application can read this object to determine that a
save operation has completed."
::= { cpqGigaSwitchSystem 4 }
cpqCurrentConfigInUse OBJECT-TYPE
SYNTAX INTEGER { primary(1), secondary(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Shows which configuration store was used at last boot"
::= { cpqGigaSwitchSystem 5 }
cpqConfigToUseOnReboot OBJECT-TYPE
SYNTAX INTEGER { primary(1), secondary(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls which configuration store will be used on next reboot."
::= { cpqGigaSwitchSystem 6 }
--
-- Assorted OIDs that are pointed to by other MIBs
--
cpqOids OBJECT IDENTIFIER ::= { cpqGigaSwitch 2 }
--
-- OIDs for as-yet-unstandardised 802.3 MAU types
-- (see MAU MIB for usage)
--
cpqMauType OBJECT IDENTIFIER ::= { cpqOids 1 }
cpqMauType1000BaseSX OBJECT IDENTIFIER ::= { cpqMauType 1 }
-- "X fiber over short-wavelength laser PMD as specified
-- in clause 38, duplex mode unknown"
cpqMauType1000BaseLX OBJECT IDENTIFIER ::= { cpqMauType 2 }
-- "X fiber over long-wavelength laser PMD as specified
-- in clause 38, duplex mode unknown"
cpqMauType1000BaseCX OBJECT IDENTIFIER ::= { cpqMauType 3 }
-- "X copper over 150-ohm balanced cable PMD as specified
-- in clause 39, duplex mode unknown"
cpqMauType1000BaseSXFD OBJECT IDENTIFIER ::= { cpqMauType 4 }
-- "X fiber over short-wavelength laser PMD as specified
-- in clause 38, full-duplex mode"
cpqMauType1000BaseLXFD OBJECT IDENTIFIER ::= { cpqMauType 5 }
-- "X fiber over long-wavelength laser PMD as specified
-- in clause 38, full-duplex mode"
cpqMauType1000BaseCXFD OBJECT IDENTIFIER ::= { cpqMauType 6 }
-- "X copper over 150-ohm balanced cable PMD as specified
-- in clause 39, full-duplex mode"
--
-- Traps
--
overheat TRAP-TYPE
ENTERPRISE cpqGigaSwitch
VARIABLES { sysUpTime, sysDescr }
DESCRIPTION
"A overheat trap indicates that the on board
tempature sensor has reported a overheat
condition. System will shutdown until unit has
sufficiently cooled such that operation may begin
again. A cold start trap will be issued when
the unit has come back on line."
--#TYPE "overheat"
--#SUMMARY "overheat"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
::= 6
fanfailed TRAP-TYPE
ENTERPRISE cpqGigaSwitch
VARIABLES { sysUpTime, sysDescr }
DESCRIPTION
"A fan failed trap indicates one or more of the
cooling fans inside the device has failed. A
fanOK trap will be sent once the fan has attained
normal operation."
--#TYPE "fanfailed"
--#SUMMARY "fanfailed"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
::= 7
fanOK TRAP-TYPE
ENTERPRISE cpqGigaSwitch
VARIABLES { sysUpTime, sysDescr }
DESCRIPTION
"A fan has transitioned out of a failure state and
is now operating correctly."
--#TYPE "fanOk"
--#SUMMARY "fanOk"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
::= 8
invalidLoginAttempt TRAP-TYPE
ENTERPRISE cpqGigaSwitch
VARIABLES { sysUpTime, sysDescr }
DESCRIPTION
"A user attempted to login to console or by telnet but was refused
access due to incorrect username or password"
--#TYPE "invalidLoginAttempt"
--#SUMMARY "invalidLoginAttempt"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
::= 9
powerSupplyFail TRAP-TYPE
ENTERPRISE cpqGigaSwitch
VARIABLES { sysUpTime, sysDescr }
DESCRIPTION
"One or more sources of power to this agent has failed.
Presumably a redundant power-supply has taken over."
--#TYPE "powerSupplyFail"
--#SUMMARY "powerSupplyFail"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
::= 10
powerSupplyGood TRAP-TYPE
ENTERPRISE cpqGigaSwitch
VARIABLES { sysUpTime, sysDescr }
DESCRIPTION
"One or more previously bad sources of power to this agent
has come back to life without causing an agent restart."
--#TYPE "powerSupplyGood"
--#SUMMARY "powerSupplyGood"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
::= 11
rpsAlarm TRAP-TYPE
ENTERPRISE cpqGigaSwitch
VARIABLES { sysUpTime, sysDescr }
DESCRIPTION
"Attached Redundant Power Supply device is indicating
an alarm condition."
--#TYPE "rpsAlrm"
--#SUMMARY "rpsAlarm"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
::= 12
rpsNoAlarm TRAP-TYPE
ENTERPRISE cpqGigaSwitch
VARIABLES { sysUpTime, sysDescr }
DESCRIPTION
"Attached Redundant Power Supply device is no longer
indicating an alarm condition."
--#TYPE "rpsNoAlarm"
--#SUMMARY "rpsNoAlarm"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
::= 13
END