snmp_mib_archive/cesTraps.mib
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

2061 lines
91 KiB
Plaintext
Executable File

--
-- Each Trap contains the Trap OID as well as the following OIDs:
-- SeverityLevel
-- (ActualTrapDetails)
-- System Name
-- System Date
-- System Time
-- System Uptime
--
--
-- (Actual Trap Details) is a string that is comprised of three sections
-- separated by colons.
-- Severity : Name of task to which the trap relates : Status message
-- Severity section will be one of these possibilities: Disabled, Warning, Alert
----------------------------------
--
-- For HP Openview; the user can use $1 $2 $3 $4 $5 $6 or
-- Severity: $1 Trap $2 System $3 $4 $5 Uptime $6
-- as a default format string in the trap.conf file,
-- otherwise, too much information will be displayed.
-- $1 Severity Level
-- $2 Actual Trap Details
-- $3 System Name
-- $4 System Date
-- $5 System Time
-- $6 System Uptime
--
CONTIVITY-TRAPS-V1-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString,
sysName,
sysObjectID,
ifIndex,
ifAdminStatus,
ifOperStatus,
ifType,
ifDescr,
snmp
FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
IpAddress FROM RFC1155-SMI
MODULE-IDENTITY FROM SNMPv2-SMI
-- SNMPv2-SMI(RFC2578 or STD58)
contivity FROM NEWOAK-MIB;
-- The following MODULE-IDENTITY definition can be commented out if the MIB parser
-- you are using has trouble parsing it. The object id defined, "contivityTrapV1",
-- is not used in the mib. It is here only for documentation purposes.
contivityTrapsV1 MODULE-IDENTITY
LAST-UPDATED "0604062300Z" -- April 6, 2006 7:00pm EST
ORGANIZATION "Nortel"
CONTACT-INFO
"support@nortel.com
Postal: Nortel
600 Technology Park Drive
Billerica, MA 01821
Tel: +1 978 670 8888
E-Mail: support@nortel.com"
DESCRIPTION
"This MIB defines the traps, and bind objects used in the traps,
that are sent by the VPN Router."
REVISION "0005122000Z" -- May 12, 2000 4:00pm EST
DESCRIPTION
"Add ifIndex, ifDescr, ifType to the following traps:
lanCardStatusTrap, t1WANStatusTrap, t3WANStatusTrap
Add ifReasonForStatus-ces, ifPhysLocation-ces,
ifPhysRelPos-ces, ifIpAddr-ces, ifTunnelName-ces,
ifTunnelRemoteIpAddr-ces to Link Up and Link Down traps.
."
REVISION "0006281800Z" -- Jul 28, 2000 2:00pm EST
DESCRIPTION
"Added Possible Values: clauses to most of the traps.
Change ifTunnelName-ces to ifName-ces.
Using ifName-ces instead of ifXName so that this mib will compile
with only V1 mibs.
"
REVISION "0006282100Z" -- Jul 28, 2000 5:00pm EST
DESCRIPTION
"Added Possible Values: to all but:
load balancing, firewall, failed login attempt, security intrusion
"
REVISION "0008101500Z" -- Aug 10, 2000 11:00am EST
DESCRIPTION
"Added Possible Values: to:
load balancing, firewall, failed login attempt, security intrusion
"
REVISION "0006182200Z" -- Jul 18, 2000 6:00pm EST
DESCRIPTION
"Add firewallPolicyType-ces,
firewallRuleType-ces, firewallRuleIntfName-ces,
firewallRuleNumber-ces, firewallSrcAddr-ces, firewallSrcPort-ces,
firewallDestAddr-ces, firewallDestPort-ces, firewallProtocolID-ces,
firewallRuleAction-ces, firewallIpHdr-ces, firewallUdpTcpHdr-ces,
firewallRuleTriggeredTrap. Change ifTunnelName-ces to ifName-ces.
Using ifName-ces instead of ifXName so that this mib will compile
with only V1 mibs.
"
REVISION "0102272300Z" -- Feb 27, 2001 7:00pm EST
DESCRIPTION
"Changed severityLevel to reflect the actual health of the object the
trap is describing.
"
REVISION "0103262300Z" -- Mar 26, 2001 7:00pm EST
DESCRIPTION
"Changed softwareCESTrapInfo to serviceCESTrapInfo.
"
REVISION "0105102300Z" -- May 10, 2001 7:00pm EST
DESCRIPTION
"Added licensingStatus trap.
"
::= { contivity 0 }
-- This MIB module uses the extended OBJECT-TYPE macro as
-- defined in [9], and the TRAP-TYPE macro as defined in [10].
-- Textual Conventions
-- PortLocation-ces defines the physical location of the port in relation to the
-- CES chassis as a whole.
PortLocation-ces ::= INTEGER {
motherBoardOrSlot0(1),
slot1(2),
slot2(3),
slot3(4),
slot4(5),
slot5(6)
}
-- IfReasonForStatus-ces provides detailed information as to why the CES has issued
-- this trap. Ex. For a branch office connection that has timed out, the timed-out
-- value would be applicable. Also for a branch office, if the remote end of the
-- tunnel stopped responding, then no-response would be applicable.
-- For physical interfaces, ip-addr-chg informs that the IP address assigned to the
-- port has changed. This TC is used for the Link Up and Link Down traps.
IfReasonForStatus-ces ::= INTEGER {
unknown(1),
idle-time-out(2),
ip-addr-chg(3),
no-response(4),
user-interaction(5),
time-limit(6),
testing(7),
test-complete-success(8),
test-complete-failure(9),
link-down(10),
link-up(11)
}
-- FirewallPolicyType-ces
FirewallPolicyType-ces ::= INTEGER {
firewall(1),
nat(2)
}
-- FirewallRuleType-ces specifies whether it was a source or destination
-- that trigger the rule.
FirewallRuleType-ces ::= INTEGER {
over-ride(1),
sourceInterface(2),
destinationInterface(3),
default(4)
}
-- FirewallRuleAction-ces specifies what is to be done with the packet.
FirewallRuleAction-ces ::= INTEGER {
unknown(1),
allow(2),
reject(3),
drop(4)
}
--
-- The following are passed with every trap.
--
severityLevel OBJECT-TYPE
SYNTAX INTEGER
{
alert(1),
warning(2),
disabled(3),
healthy(4),
unknown(5)
-- fatal(1),
-- major(2),
-- minor(3),
-- informational(4),
-- insignificant(5),
-- reversal(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Severity of specific trap."
::= {contivity 7}
systemName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "System Name."
::= {contivity 8}
systemDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "System Date."
::= {contivity 9}
systemTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "System Time."
::= {contivity 10}
systemUpTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "System Up Time."
::= {contivity 11}
-- Groups
-- Hardware related Traps
hardwareCESTrapInfo OBJECT IDENTIFIER
::= {contivity 1}
-- Trap #1001 ---------------------------------
hardDisk1Status OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Hard Disk Number 1 Status.
Possible Values:
Warning: Hard Disk 1 : Device /ide1/ not available
Warning: Hard Disk 1 : Utilization exceeds 75%% on /ide1/
Alert: Hard Disk 1 : Utilization exceeds 87.5%% on /ide1/
"
::= {hardwareCESTrapInfo 1}
hardDisk1StatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,hardDisk1Status, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Hard Disk Number 1 Status"
::= 1001
-- Trap #1002 ---------------------------------
hardDisk0Status OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Hard Disk Number 0 Status.
Possible Values:
Warning: Hard Disk 0 : Device /ide0/ not available
Warning: Hard Disk 0 : Utilization exceeds 75%% on /ide0/
Alert: Hard Disk 0 : Utilization exceeds 87.5%% on /ide0/
"
::= {hardwareCESTrapInfo 2}
hardDisk0StatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,hardDisk0Status, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Hard Disk Number 0 Status"
::= 1002
-- Trap #1003 ---------------------------------
memoryUsage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Memory Usage Status.
Possible Values:
Warning: Memory Usage : Utilization exceeds 75%
Alert: Memory Usage : Utilization exceeds 87.5%
"
::= {hardwareCESTrapInfo 3}
memoryUsageTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,memoryUsage, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Memory Usage Status"
::= 1003
-- Trap #1004 ---------------------------------
lanCardStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of any LAN cards on the system.
Possible Values:
Please note that X corresponds to the Xth slot in the system.
Please note that Y corresponds to the relative position of the port
on the card in the Xth slot in the system.
Warning: LAN on Slot X Interface Y: Device feiX has no IP address;
Warning: LAN on Slot X Interface Y: Device feiX disabled;
Alert: LAN on Slot X Interface Y: Device feiX down;
Alert: LAN on Slot X Interface Y: Device feiX Invalid Device X
The Alert status above indicates that the interface has no
link when it should. Possible causes are improper connection
speeds and duplex, improper cabling or a configuration issue."
::= {hardwareCESTrapInfo 4}
lanCardStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,
lanCardStatus,
systemName,
systemDate,
systemTime,
systemUpTime,
ifIndex, -- ifIndex of the interface.
ifDescr, -- ifDescr of the interface.
ifType -- ifType, this provides descrimination of interfaces that are tunnels.
}
DESCRIPTION "Status of any LAN cards on the system"
::= 1004
-- Trap #1005 ---------------------------------
cpuTwoStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of second CPU.
Possible Values:
Alert: CPU 2: Program load failed;
Alert: CPU 2: Bootup did not complete;
Alert: CPU 2: Communication lost;
Alert: CPU 2: Failed. Reason unknown;
Each of these indicates that the application CPU is
not functioning correctly. The system will continue to
function without the application processor. This can only
be sent from a system with multiple CPUs. See the Admin
Guide for a list of systems that contain multiple CPUs.
The CES will emit an audible alarm and the networking
performance will be degraded. A Nortel support
representative should be contacted if rese ing the CES
does not correct the problem.
The effect is the same in each case. The system will be
running with only one CPU."
::= {hardwareCESTrapInfo 5}
cpuTwoStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,cpuTwoStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of second CPU.
"
::= 1005
-- Trap #1006 ---------------------------------
fanOneStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of the first CPU fan.
Possible Values:
Alert: CPU One Fan: Fan not functioning;
This indicates that the fan on the primary processor is
running either below the specified speed or not running
at all. If a fan is not working correctly, it must be
fixed as soon as possible or damage may result.
This is a high priority event which can prove catastrophic
to the processor as well as the system. This trap can only
be sent by systems which contain an actual fan on the
primary CPU."
::= {hardwareCESTrapInfo 6}
fanOneStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,fanOneStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of the first CPU fan"
::= 1006
-- Trap #1007 ---------------------------------
fanTwoStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of the second CPU fan
Possible Values:
Alert: CPU Two Fan: Fan not functioning;
This indicates that the fan on the auxiliary processor is
running either below the specified speed or not running
at all. If a fan is not working correctly, it must be
fixed as soon as possible or damage may result.
This is a high priority event which can prove catastrophic
to the processor as well as the system. This trap can only
be sent by systems which contain an actual fan on the
auxiliary CPU."
::= {hardwareCESTrapInfo 7}
fanTwoStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,fanTwoStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of the second CPU fan"
::= 1007
-- Trap #1008 ---------------------------------
chassisFanStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of the chassis fan.
Possible Values:
Alert: Chassis Fan: Fan not functioning;
Alert: Chassis Fan 2: Fan not functioning;
This indicates that one of the chassis fans is running
either below the specified range of speed or not running
at all. If a fan is not working correctly, it must be
fixed as soon as possible or damage may result.
If either of the fans are not working properly, the box
must be looked at by a service technician as soon as
possible. Not doing so will result in overheating of
the system, improper system operation, and possible
component failure."
::= {hardwareCESTrapInfo 8}
chassisFanStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,chassisFanStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of the chassis fan."
::= 1008
-- Trap #1009 ---------------------------------
fiveVoltsPositive OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of +5 Volt power.
Possible Values:
Alert: Voltage 5 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages."
::= {hardwareCESTrapInfo 9}
fiveVoltsPosStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,fiveVoltsPositive, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of the +5 Volt power"
::= 1009
-- Trap #10010 ---------------------------------
fiveVoltsMinus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of -5 Volt power.
Possible Values:
Alert: Voltage 5 V Minus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages."
::= {hardwareCESTrapInfo 10}
fiveVoltsMinusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,fiveVoltsMinus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of -5 Volt power"
::= 10010
-- Trap #10011 ---------------------------------
threeVoltsPositive OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of +3 Volt power.
Possible Values:
Alert: Voltage 3.3 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages."
::= {hardwareCESTrapInfo 11}
threeVoltsPositiveTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,threeVoltsPositive, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of +3 Volt power"
::= 10011
-- Trap #10012 ---------------------------------
twoDotFiveVA OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of 2.5VA power.
Possible Values:
Alert: Voltage 2.5 VA: Voltage out of range;
This is the voltage supplied to the primary processor.
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages."
::= {hardwareCESTrapInfo 12}
twoDotFiveVATrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,twoDotFiveVA, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of 2.5VA power"
::= 10012
-- Trap #10013 ---------------------------------
twoDotFiveVB OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of 2.5VB power.
Possible Values:
Alert: Voltage 2.5 VB: Voltage out of range;
This is the voltage supplied to the seconary processor.
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages."
::= {hardwareCESTrapInfo 13}
twoDotFiveVBTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,twoDotFiveVB, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of 2.5VB power"
::= 10013
-- Trap #10014 ---------------------------------
twelveVoltsPositive OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of +12 Volt power.
Possible Values:
Alert: Voltage 12 V Plus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages."
::= {hardwareCESTrapInfo 14}
twelveVoltsPositveTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,twelveVoltsPositive, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of +12 Volt power"
::= 10014
-- Trap #10015 ---------------------------------
twelveVoltsMinus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of -12 Volt power.
Possible Values:
Alert: Voltage 12 V Minus: Voltage out of range;
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages."
::= {hardwareCESTrapInfo 15}
twelveVoltsMinsTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,twelveVoltsMinus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of -12 Volt power"
::= 10015
-- Trap #10016 ---------------------------------
normalTemperature OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of normal temperature reading.
Possible Values:
Alert: Normal Temperature: Normal temperature out of range;
This indicates that the box is running above its rated
normal operating temperature. This may be the result of
an improperly working fan or a high ambient temperature.
The box is not guaranteed to run properly while running
above the normal operating temperature range. Performance
will be degraded. Not taking action to correct this
situation can result in component failure. Do not rely
on waiting for the criticalTemperatureTrap as that is
only supported by certain platforms."
::= {hardwareCESTrapInfo 16}
normalTemperatureTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,normalTemperature, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of the normal temperature reading"
::= 10016
-- Trap #10017 ---------------------------------
criticalTemperature OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of critical temperature reading.
Possible Values:
Alert: Critical Temperature: Critial temperature out of range;
This indicates that the box is running at a critically high
temperature above the normal operating range. This is only
supported on certain platforms. See the Admin Guide for a
list of platforms which support this.
The box must be shut down immediately. Component failure
may already have occurred. If the reason for such a high
operating temperature cannot be determined, contact a
qualified Nortel representative."
::= {hardwareCESTrapInfo 17}
criticalTemperatureTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,criticalTemperature, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of the critical temperature reading"
::= 10017
-- Trap #10018 ---------------------------------
chassisIntrusion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The chassis intrusion sensor indicates that the unit has been opened.
Possible Values:
Alert: Intrusion: Box has been opened;
The cover to the CES has been opened or is in the
process of being opened. This indicates a possible
physical security intrusion.
The system will continue to operate while the box
is opened. Check to insure that no unauthorized
persons have opened the unit."
::= {hardwareCESTrapInfo 18}
chassisIntrusionTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,chassisIntrusion, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "The chassis intrusion sensor indicates that the unit has been physically opened"
::= 10018
-- Trap #10019 ---------------------------------
dualPowerSupply OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of the redundant power supplies.
Possible Values:
Alert: Dual Power Supply: Redundant supply faulted
This indicates that, on systems with redundant power
supplies, one of the power supplies is not working.
This trap can only be sent from systems which have
redundant power supplies. The system will continue
to run with only one power supply working. A new
power supply must be obtained via an authorized
Nortel representative as quickly as possible.
This will help reduce the risk window of system failure
in the event that the working power supply ceases to
function."
::= {hardwareCESTrapInfo 19}
dualPowerSupplyTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,dualPowerSupply, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of the redundant power supplies"
::= 10019
-- Trap #10020 ---------------------------------
t1WANStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of T1 WAN card(s).
Possible Values:
For Wanic support:
Alert: Invalid Device X
Warning: Device WanicX disabled
Alert: Device WanicX down
Warning: Device WanicX not initialized
Warning: Device WanicX PPP negotiating
Alert: Device WanicX PPP down
Alert: Device WanicX FR no support
Alert: Device WanicX Unknown DL
For T1:
Alert: Invalid Device X
Warning: Device LMCDTEX disabled
Alert: Device LMCDTEX down
Warning: Device LMCDTEX not initialized
For CSU/DSU:
Alert: Invalid Device X
Warning: Device LMCCDX disabled
Alert: Device LMCCDX down
Warning: Device LMCCDX not initialized"
::= {hardwareCESTrapInfo 20}
t1WANStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,
t1WANStatus,
systemName,
systemDate,
systemTime,
systemUpTime,
ifIndex, -- ifIndex of the interface.
ifDescr, -- ifDescr of the interface.
ifType -- ifType, this provides descrimination of interfaces that are tunnels.
}
DESCRIPTION "Status of T1 WAN card(s).
Possible Values:
For Wanic support:
Alert: Invalid Device X
Warning: Device WanicX disabled
Alert: Device WanicX down
Warning: Device WanicX not initialized
Warning: Device WanicX PPP negotiating
Alert: Device WanicX PPP down
Alert: Device WanicX FR no support
Alert: Device WanicX Unknown DL
For T1:
Alert: Invalid Device X
Warning: Device LMCDTEX disabled
Alert: Device LMCDTEX down
Warning: Device LMCDTEX not initialized
For CSU/DSU:
Alert: Invalid Device X
Warning: Device LMCCDX disabled
Alert: Device LMCCDX down
Warning: Device LMCCDX not initialized"
::= 10020
-- Trap #10021 ---------------------------------
t3WANStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of T3 WAN card
Possible Values:
Alert: Invalid Index X
Warning: Device HSSIX disabled
Alert: Device HSSIX down
Warning: Device HSSIX not initialized
Alert: Device HSSIX PPP down
Warning: Device HSSIX PP initializing"
::= {hardwareCESTrapInfo 21}
t3WANStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,
t3WANStatus,
systemName,
systemDate,
systemTime,
systemUpTime,
ifIndex, -- ifIndex of the interface.
ifDescr, -- ifDescr of the interface.
ifType -- ifType, this provides descrimination of interfaces that are tunnels.
}
DESCRIPTION "Status of T3 WAN card
Possible Values:
Alert: Invalid Index X
Warning: Device HSSIX disabled
Alert: Device HSSIX down
Warning: Device HSSIX not initialized
Alert: Device HSSIX PPP down
Warning: Device HSSIX PP initializing"
::= 10021
-- Trap #10022 ---------------------------------
hwAccelStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of hardware accelerator card."
::= {hardwareCESTrapInfo 22}
hwAccelTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,hwAccelStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of hardware accelerator card.
Possible Values:
Invalid hardware accelerator unit %d;
Unknown hardware accelerator unit %d;
Healthy: Bulk Accelerator in slot %d: Unit %d Status 1 - ATTACHED;
Warning: Bulk Accelerator in slot %d: Unit %d Status 2 - DISABLED;
Healthy: Bulk Accelerator in slot %d: Unit %d Status 3 - ACTIVE;
Warning: Bulk Accelerator in slot %d: Unit %d Status 4 - RECOVERING;
Warning: Bulk Accelerator in slot %d: Unit %d Status 5 - SHUTDOWN;
Alert: Bulk Accelerator in slot %d: Unit %d Status 6 - FAILED;
"
::= 10022
-- Trap #10024 ---------------------------------
v90WANStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: V.90 Invalid index X
Disabled: Device IntModem-X disabled
Healthy: Device IntModem-X: PPP is UP.
Alert: Device IntModem-X down
Warning: Device IntModem-X not initialized
Alert: Device IntModem-X: Call is UP. Internal Error.
Warning: Device IntModem-X is Down. Last dial-out attempt FAILED.
Healthy: Device IntModem-X is Down (No Active calls)
Warning: Device IntModem-X is in an UNKNOWN state"
::= {hardwareCESTrapInfo 24}
v90WANStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,
v90WANStatus,
systemName,
systemDate,
systemTime,
systemUpTime
}
DESCRIPTION "Status of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: V.90 Invalid index X
Disabled: Device IntModem-X disabled
Healthy: Device IntModem-X: PPP is UP.
Alert: Device IntModem-X down
Warning: Device IntModem-X not initialized
Alert: Device IntModem-X: Call is UP. Internal Error.
Warning: Device IntModem-X is Down. Last dial-out attempt FAILED.
Healthy: Device IntModem-X is Down (No Active calls)
Warning: Device IntModem-X is in an UNKNOWN state
"
::= 10024
-- Trap #10025 ---------------------------------
briWANStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of ISDN BRI Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: BRI Invalid index X
Alert: Device BRI-X not Responding. Needs Host Reboot.
Disabled: Device BRI-X disabled
Alert: Device BRI-X down
Warning: Device BRI-X not initialized
Healthy: Device BRI-X: PPP is UP.
Alert: Device BRI-X: Call is UP. Internal Error.
Warning: Device BRI-X is Down. Last dial-out attempt FAILED.
Healthy: Device BRI-X is Down (No Active calls)
Alert: Device BRI-X is in an UNKNOWN state"
::= {hardwareCESTrapInfo 25}
briWANStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,
briWANStatus,
systemName,
systemDate,
systemTime,
systemUpTime
}
DESCRIPTION "Status of V.90 Interface card
Possible Values:
Please note that X corresponds to the unit number of the card.
Alert: BRI Invalid index X
Alert: Device BRI-X not Responding. Needs Host Reboot.
Disabled: Device BRI-X disabled
Alert: Device BRI-X down
Warning: Device BRI-X not initialized
Healthy: Device BRI-X: PPP is UP.
Alert: Device BRI-X: Call is UP. Internal Error.
Warning: Device BRI-X is Down. Last dial-out attempt FAILED.
Healthy: Device BRI-X is Down (No Active calls)
Alert: Device BRI-X is in an UNKNOWN state
"
::= 10025
-- Trap #10026 ---------------------------------
serUartStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of Serial (COM) port/interface
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: COM port Invalid index X
Healthy: Device COMX is set for Serial Menu.
Disabled: Device COMX disabled
Warning: Device COMX not initialized
Healthy: Device COMX: PPP is UP.
Alert: Device COMX: Call is UP. Internal Error.
Warning: Device COMX is Down. Last dial-out attempt FAILED.
Healthy: Device COMX is Down (No Active calls)
Alert: Device COMX is in an UNKNOWN state"
::= {hardwareCESTrapInfo 26}
serUartStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,
serUartStatus,
systemName,
systemDate,
systemTime,
systemUpTime
}
DESCRIPTION "Status of Serial (COM) port/interface
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: COM port Invalid index X
Healthy: Device COMX is set for Serial Menu.
Disabled: Device COMX disabled
Warning: Device COMX not initialized
Healthy: Device COMX: PPP is UP.
Alert: Device COMX: Call is UP. Internal Error.
Warning: Device COMX is Down. Last dial-out attempt FAILED.
Healthy: Device COMX is Down (No Active calls)
Alert: Device COMX is in an UNKNOWN state
"
::= 10026
-- Trap #10027 ---------------------------------
adslWANStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of ADI ADSL card
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: Invalid index X
Alert: Device ADIADSLX off line
Disabled: Device ADIADSLX disabled
Alert: Device ADIADSLX down
Warning: Device ADIADSLX not initialized
Healthy: Device ADIADSLX up"
::= {hardwareCESTrapInfo 27}
adslWANStatusTrap TRAP-TYPE
ENTERPRISE hardwareCESTrapInfo
VARIABLES {
severityLevel,
adslWANStatus,
systemName,
systemDate,
systemTime,
systemUpTime
}
DESCRIPTION "Status of ADI ADSL card
Possible Values:
Please note that X corresponds to the unit number of the serial interface
Alert: Invalid index X
Alert: Device ADIADSLX off line
Disabled: Device ADIADSLX disabled
Alert: Device ADIADSLX down
Warning: Device ADIADSLX not initialized
Healthy: Device ADIADSLX up
"
::= 10027
-- Server related Traps
serverCESTrapInfo OBJECT IDENTIFIER
::= {contivity 2}
-- Trap #3001 ---------------------------------
radiusAcctServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of External Radius Accounting Server.
Possible Values:
Warning: RADIUS Accounting Server: Server not configured
Alert: RADIUS Accounting Server: Error
Alert: RADIUS Accounting Server: Not Configured
"
::= {serverCESTrapInfo 1}
radiusAcctServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,radiusAcctServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of External Radius Accounting Server"
::= 3001
-- Trap #3002 ---------------------------------
backupServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of External Disk Backup Server.
Possible Values:
Warning: Auto Backup Servers: Server not configured.
Warning: Auto Backup Servers: Can't backup to xxx yyy zzz
Alert: Auto Backup Servers: Can't backup to xxx yyy zzz
Can't backup to xxx yyy zzz is issued as an alert
when none of the servers can be reached.
"
::= {serverCESTrapInfo 2}
backupServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,backupServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of External Disk Backup Server"
::= 3002
-- Trap #3003 ---------------------------------
diskRedundency OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of Local Disk Redundency.
Possible Values:
Alert: Disk Redundancy: Not Configured
Alert: Disk Redundancy: Error
"
::= {serverCESTrapInfo 3}
diskRedundencyTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,diskRedundency, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of Local Disk Redundency"
::= 3003
-- Trap #3004 ---------------------------------
intLDAPServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of Internal LDAP Server.
Possible Values:
Warning : Internal LDAP Server : Restore in progress
Alert : Internal LDAP Server : Server is down
"
::= {serverCESTrapInfo 4}
intLDAPServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,intLDAPServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of Internal LDAP Server"
::= 3004
-- Trap #3005 ---------------------------------
loadBalancingServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of Load Balancing Server.
Possible Values:
Disabled: Load Balancing Service: Server not enabled;
Warning: Load Balancing Service: Timed out waiting for response from server;
"
::= {serverCESTrapInfo 5}
loadBalancingServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,loadBalancingServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of Load Balancing Server"
::= 3005
-- Trap #3006 ---------------------------------
dnsServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of DNS Server.
Possible Values:
Warning: DNS Servers : Error
Warning: DNS Servers : Operational
Alert: DNS Servers : Configured
Alert: DNS Servers : Error
The values have the following meaning:
Warning: DNS Servers : Error -- SysInitCls::InitComplete failed
Warning: DNS Servers : Operational -- At least one of the servers is reachable
Alert: DNS Servers : Configured -- All servers configured, but none are reachable.
Alert: DNS Servers : Error --
"
::= {serverCESTrapInfo 6}
dnsServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,dnsServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of DNS Server"
::= 3006
-- Trap #3007 ---------------------------------
snmpServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of SNMP Server.
Possible Values:
Warning: SNMP Servers : Error
Warning: SNMP Servers : Can't reach xxx.xxx.xxx.xxx or yyy.yyy.yyy.yyy
Alert: SNMP Servers : Error
The values have the following meaning:
Warning: SNMP Servers : Error -- SysInitCls::InitComplete failed
Alert: SNMP Servers : Error -- AT least one server configured, but none are reachable.
"
::= {serverCESTrapInfo 7}
snmpServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,snmpServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of SNMP Server"
::= 3007
-- Trap #3008 ---------------------------------
ipAddressPool OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of the IP address pool.
Possible Values:
Warning: IP Address Pool : Reserved address count is low.
Warning: IP Address Pool : DHCP server(s) unavailable
Alert: IP Address Pool : Server is down
Alert: IP Address Pool : Not Configured
Alert: IP Address Pool : No IP address available.
Alert: IP Address Pool : Reserved address count is low.
Alert: IP Address Pool : Associated system task failed.
Alert: IP Address Pool : Server not configured
Alert: IP Address Pool : Error
The values have the following meaning:
Warning: IP Address Pool : Reserved address count is low. -- Haven't hit desired cache size yet.
Alert: IP Address Pool : Server is down -- SysInitCls::InitComplete failed
Alert: IP Address Pool : Not Configured -- Task failed sanity check.
Alert: IP Address Pool : No IP address available. -- No addresses in BOUND state.
Alert: IP Address Pool : Associated system task failed.
Alert: IP Address Pool : Server not configured
Alert: IP Address Pool : Error
"
::= {serverCESTrapInfo 8}
ipAddressPoolTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,ipAddressPool, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of the IP address pool"
::= 3008
-- Trap #3009 ---------------------------------
extLDAPServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of External LDAP Server.
Possible Values:
Warning: External LDAP Servers : Server is down
Alert: External LDAP Servers : Server is down
The values have the following meaning:
Warning: External LDAP Servers : Server is down -- One server is down
Alert: External LDAP Servers : Server is down -- All servers are down
"
::= {serverCESTrapInfo 9}
extLDAPServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,extLDAPServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of External LDAP Server"
::= 3009
-- Trap #30010 ---------------------------------
radiusAuthServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of Radius Authentication Server.
Possible Values:
Warning: RADIUS Authentication Servers : Error
Alert: RADIUS Authentication Servers : Error
The values have the following meaning:
Warning: RADIUS Authentication Servers : Error -- At least one server is available
Alert: RADIUS Authentication Servers : Error -- No servers are available
"
::= {serverCESTrapInfo 10}
radiusAuthServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,radiusAuthServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of Radius Authentication Server"
::= 30010
-- Trap #30011 ---------------------------------
certificateServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of Certificates Validity.
Possible Values:
Alert: Certificates Validity: All certificates are going to expire/expired;
Warning: Certificates Validity: One/more certificate is invalid;
Disabled: Certificates Validity: No certificate defined;
"
::= {serverCESTrapInfo 11}
certificateServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,certificateServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of Certificates Validity
Possible Values:
Healthy: Certificates Validity: Operational;
Alert: Certificates Validity: All certificates are going to expire/expired;
Warning: Certificates Validity: One/more certificate is invalid;
Disabled: Certificates Validity: No certificate defined;
"
::= 30011
-- Trap #30012 ---------------------------------
extLDAPAuthServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of External LDAP Authentication Server.
Possible Values:
Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable);
Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);
"
::= {serverCESTrapInfo 12}
extLDAPAuthServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel,certificateServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of External LDAP Authentication Server.
Possible Values:
Warning: External LDAP Authentication Server: Server is down(indicates at least one server is not reachable and at least one server is reachable);
Alert: External LDAP Authentication Server: Server is down(indicates all servers are not reachable);
"
::= 30012
-- Trap #30013 ---------------------------------
cmpServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of CMP Server.
Possible Values:
One/more Certificate Requests error: there is at least one request error;
One/more Certificate Requests processing: there is at least one request in processing;
No Certificate Requests submitted: there is no request sent;
"
::= {serverCESTrapInfo 13}
cmpServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel, cmpServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of CMP Server.
Possible Values:
One/more Certificate Requests error: there is at least one request error;
One/more Certificate Requests processing: there is at least one request in processing;
No Certificate Requests submitted: there is no request sent;
"
::= 30013
-- Trap #30014 ---------------------------------
dhcpServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of DHCP Server.
Possible Values:
Disabled: DHCP Server is Disabled
Alert: DHCP Server is NOT configured
Alert: DHCP Server is configured and operational, Using backup config
Alert: No IP Address available for subnet
Alert: DHCP Server is configured and server is DOWN
Healthy: DHCP Server is Operational
Warning: Subnet low on IP Addresses
Warning: DHCP Server Initializing
Warning: DHCP Server is Enabled, but status Unknown cannot be determined
"
::= {serverCESTrapInfo 14}
dhcpServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel, dhcpServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of DHCP Server
Possible Values:
Disabled: DHCP Server is Disabled
Alert: DHCP Server is NOT configured
Alert: DHCP Server is configured and operational, Using backup config
Alert: No IP Address available for subnet
Alert: DHCP Server is configured and server is DOWN
Healthy: DHCP Server is Operational
Warning: Subnet low on IP Addresses
Warning: DHCP Server Initializing
Warning: DHCP Server is Enabled, but status Unknown cannot be determined
"
::= 30014
-- Trap #30015 ---------------------------------
crlServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of CRL Server.
"
::= {serverCESTrapInfo 15}
crlServerTrap TRAP-TYPE
ENTERPRISE serverCESTrapInfo
VARIABLES {
severityLevel, crlServer, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of CRL Server.
"
::= 30015
-- Software related Traps
serviceCESTrapInfo OBJECT IDENTIFIER
::= {contivity 3}
-- Trap #5001 ---------------------------------
netBuffers OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Network buffer usage.
Possible Values:
Warning: Buffer Usage : Utilization exceeds 75%
Alert: Buffer Usage : Utilization exceeds 87.5%
"
::= {serviceCESTrapInfo 1}
netBuffersTrap TRAP-TYPE
ENTERPRISE serviceCESTrapInfo
VARIABLES {
severityLevel,netBuffers, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Network buffer usage"
::= 5001
-- Trap #5002 ---------------------------------
fireWall OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of internal firewall.
Possible Values:
Disabled: Firewall: Firewall disabled;
Disabled: Firewall: Firewall stopped;
Warning: Firewall: Current Firewall is %s. Reboot is required to start %s;
Warning: Firewall: Firewall state is not known!;
Warning: Firewall: Daemon loading policy;
Alert: Firewall: Firewall requires reboot to start;
Alert: Firewall: Daemon task does not exist;
Alert: Firewall: Daemon task is suspended;
The values have the following meaning:
-- The first two possible values are common to all firewalls.
Disabled: Firewall: Firewall disabled;
Warning: Firewall: Current Firewall is %s. Reboot is required to start %s;
-- The firewall type (Contivity / CheckPoint) has been changed, but for it
-- to take effect, the VPN Router must be restarted.
-- Contivity Firewall specific values.
Warning: Firewall: Firewall state is not known!; -- The Contivity firewall's
-- state cannot be determined.
-- CheckPoint Firewall specific values.
Disabled: Firewall: Firewall stopped;
Warning: Firewall: Daemon loading policy;
Alert: Firewall: Firewall requires reboot to start;
Alert: Firewall: Daemon task does not exist;
Alert: Firewall: Daemon task is suspended;
"
::= {serviceCESTrapInfo 2}
fireWallTrap TRAP-TYPE
ENTERPRISE serviceCESTrapInfo
VARIABLES {
severityLevel,fireWall, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of internal firewall"
::= 5002
-- Trap #5003 ---------------------------------
fipsStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of FIPS.
Possible Values:
Warning: FIPS: Random generator test failed;
Warning: FIPS: DESMAC check on executables Failed;
Warning: FIPS: DES KAT Test Failed;
Warning: FIPS: SHA1 Self Test Failed;
Alert: FIPS: status not known;"
::= {serviceCESTrapInfo 3}
fipsStatusTrap TRAP-TYPE
ENTERPRISE serviceCESTrapInfo
VARIABLES {
severityLevel,fipsStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of FIPS"
::= 5003
-- Trap #5004 ---------------------------------
licensingStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of temporary SW Licenses.
Possible Values:
Warning: Licensing: Temporary key will expire within 5 days;
Alert: Licensing: Temporary key has expired;"
::= {serviceCESTrapInfo 4}
licensingStatusTrap TRAP-TYPE
ENTERPRISE serviceCESTrapInfo
VARIABLES {
severityLevel,licensingStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status temporary SW Licenses"
::= 5004
-- Trap #5005 ---------------------------------
natStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of Network Address Translator.
Possible Values:
Disabled: NAT: NAT disabled;
Warning: NAT: Reboot is required to start Interface NAT;
Warning: NAT: NAT state is not known!;
Alert: NAT: All Addresses in the Address Translation pool are used;
Alert: NAT: LDAP policy parse failed - Using system default policy;
The values have the following meaning:
-- The first two possible values are common to all firewalls.
Disabled: NAT: NAT disabled; Existing NAT sessions are not deleted, but
-- no new address bindings are created for Interface NAT. Branch Office NAT
-- is not affected.
Warning: NAT: Reboot is required to start Interface NAT;
-- To take effect, the VPN Router must be restarted.
"
::= {serviceCESTrapInfo 5}
natStatusTrap TRAP-TYPE
ENTERPRISE serviceCESTrapInfo
VARIABLES {
severityLevel,natStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of Network Address Translator"
::= 5005
-- Trap #5006 ---------------------------------
antiSpoofingStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of Anti Spoofing Feature.
Possible Values:
Disabled: Anti-Spoofing is Disabled;
Warning: Anti-Spoofing : Packets Dropped;
Alert: Anti-Spoofing state not known!;
The values have the following meaning:
-- The first means the feature is disabled
-- The second means packets were dropped due to a detected spoofed address
-- The third should never happen, but means the status has been set to a bogus value.
"
::= {serviceCESTrapInfo 6}
antiSpoofingStatusTrap TRAP-TYPE
ENTERPRISE serviceCESTrapInfo
VARIABLES {
severityLevel, antiSpoofingStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of Anti Spoofing Feature"
::= 5006
-- Trap #5007 ---------------------------------
sslVpnStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of SSL-VPN Accelerator.
Possible Values:
Disabled: Disabled -- The unit is administrativley disabled.
Disabled: HW not installed -- There is no SSL-VPN Accelerator installed.
Warning: Initialization in progress. -- The unit is being Initialized.
Warning: Configuration Errors - see eventlog for details.
Healthy: Operational -- The unit is Operational.
Alert: Unreachable: Error Comminicating with SSL-VPN
"
::= {serviceCESTrapInfo 7}
sslVpnStatusTrap TRAP-TYPE
ENTERPRISE serviceCESTrapInfo
VARIABLES {
severityLevel, sslVpnStatus, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Status of SSL-VPN Accelerator"
::= 5007
-- Login related Traps
loginCESTrapInfo OBJECT IDENTIFIER
::= {contivity 4}
-- Trap #101 ---------------------------------
failedLogin OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Failed Login Attempt.
Possible Values:
Failed Login Attempt: Username=IPSEC Encrypted: Date/Time=(xx) ;
Failed Login Attempt: Username=(userid): Date/Time=(xx) ;
Failed Login Attempt. Invalid Account: Username=(userid): Date/Time=(xx) ;
Failed Remote Network Login: Username=(userid): Date/Time=(xx) ;
Failed Remote Application Login: Username=(userid): Date/Time=(xx) ;
The values have the following meaning:
--(userid) is a place holder for the actual userid of the person or branch office
--trying to login.
--(xx) is a place holder for the date and time string.
"
::= {loginCESTrapInfo 1}
failedLoginTrap TRAP-TYPE
ENTERPRISE loginCESTrapInfo
VARIABLES {
severityLevel,failedLogin, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Failed Login Attempt"
::= 101
-- Intrusion related Traps
intrusionCESTrapInfo OBJECT IDENTIFIER
::= {contivity 5}
-- Trap #201 ---------------------------------
securityIntrusion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Security Intrusion.
Possible Values:
Intruder: : Source: %s, Destination: %s;
"
::= {intrusionCESTrapInfo 1}
securityIntrusionTrap TRAP-TYPE
ENTERPRISE intrusionCESTrapInfo
VARIABLES {
severityLevel,securityIntrusion, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Security Intrusion"
::= 201
-- System related Traps
-- Trap #401 ---------------------------------
powerUpTrap OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS deprecated
DESCRIPTION "Power Up.
Possible Values:
Cold Start
"
::= {contivity 6}
powerUpTrapEntry TRAP-TYPE
ENTERPRISE contivity
VARIABLES {
severityLevel,powerUpTrap, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Power Up"
::= 401
-- Trap #601 ---------------------------------
periodicHeartbeat OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Periodic Heartbeat.
Possible Values:
Has been executed n times
"
::= {contivity 12}
periodicHeartbeatTrap TRAP-TYPE
ENTERPRISE contivity
VARIABLES {
severityLevel,periodicHeartbeat, systemName,systemDate, systemTime, systemUpTime
}
DESCRIPTION "Periodic Heartbeat"
::= 601
-- SNMP Agent related Traps
snmpAgentTrapInfo-ces OBJECT IDENTIFIER
::= {contivity 14}
-- coldStart ---------------------------------
coldStart TRAP-TYPE
ENTERPRISE snmp
-- VARIABLES { }
DESCRIPTION
"A coldStart trap signifies that the SNMPv2 entity, acting
in an agent role, is reinitializing itself and that its
configuration may have been altered."
::= 0
snmpAgentInterfaceInfo-ces OBJECT IDENTIFIER
::= {snmpAgentTrapInfo-ces 2}
ifReasonForStatus-ces OBJECT-TYPE
SYNTAX IfReasonForStatus-ces
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reason for the status change. These include:
unknown(1) -- the reason could not be determined.
timed-out(2) -- connection(tunnel) timed out.
"
::= {snmpAgentInterfaceInfo-ces 1}
ifPhysLocation-ces OBJECT-TYPE
SYNTAX PortLocation-ces
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The physical location of the port. This has the values of
motherBoardOrSlot0, slot1, slot2, slot3, slot4, slot5."
::= {snmpAgentInterfaceInfo-ces 2}
ifPhysRelPos-ces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The relative position of the physical port at the
location defined by interfacePhysLocation."
::= {snmpAgentInterfaceInfo-ces 3}
ifIpAddr-ces OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "For physical ports this is the associated IP address.
For a tunnel connection it is the local IP address."
::= { snmpAgentInterfaceInfo-ces 4}
ifName-ces OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of the interface, same as ifName."
::= {snmpAgentInterfaceInfo-ces 5}
ifTunnelRemoteIpAddr-ces OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The remote IP address of a tunnel connection."
::= { snmpAgentInterfaceInfo-ces 6}
-- linkDown ---------------------------------
linkDown TRAP-TYPE
ENTERPRISE snmp
VARIABLES { ifIndex, ifAdminStatus, ifOperStatus, ifDescr, ifType,
ifReasonForStatus-ces, ifPhysLocation-ces, ifPhysRelPos-ces,
ifIpAddr-ces, ifName-ces, ifTunnelRemoteIpAddr-ces,
sysObjectID, sysName }
DESCRIPTION
"A linkDown trap signifies that the sending
protocol entity recognizes a failure in one of
the communication links represented in the
agent's configuration.
Varbind list:
ifIndex -- ifIndex of the interface.
ifAdminStatus -- ifAdminStatus of the interface.
ifOperStatus -- ifOperStatus of the interface.
ifDescr -- ifDescr of the interface.
ifType -- ifType, this provides descrimination of interfaces that are tunnels.
ifReasonForStatus-ces -- reason for the change in status.
ifPhysLocation-ces -- this is the slot number.
ifPhysRelPos-ces -- the port number on the board defined in interfacePhysLocation.
ifIpAddr-ces -- IP address assigned to the phys port or the local IP address of a tunnel.
ifName-ces -- Name of the tunnel or physical interface.
ifTunnelRemoteIpAddr-ces -- for non-tunnel interfaces it is zero.
sysObjectID -- sysObjectID of the unit.
sysName -- sysName of the unit.
"
::= 2
-- linkUp ---------------------------------
linkUp TRAP-TYPE
ENTERPRISE snmp
VARIABLES { ifIndex, ifAdminStatus, ifOperStatus, ifDescr, ifType,
ifReasonForStatus-ces, ifPhysLocation-ces, ifPhysRelPos-ces,
ifIpAddr-ces, ifName-ces, ifTunnelRemoteIpAddr-ces,
sysObjectID, sysName }
DESCRIPTION
"A linkUp trap signifies that the sending
protocol entity recognizes that one of the
communication links represented in the agent's
configuration has come up.
Varbind list:
ifIndex -- ifIndex of the interface.
ifAdminStatus -- ifAdminStatus of the interface.
ifOperStatus -- ifOperStatus of the interface.
ifDescr -- ifDescr of the interface.
ifType -- ifType, this provides descrimination of interfaces that are tunnels.
ifReasonForStatus-ces -- reason for the change in status
ifPhysLocation-ces -- this is the slot number.
ifPhysRelPos-ces -- the port number on the board defined in interfacePhysLocation.
ifIpAddr-ces -- IP address assigned to the phys port or the local IP address of a tunnel.
ifName-ces -- Name of the tunnel or physical interface.
ifTunnelRemoteIpAddr-ces -- for non-tunnel interfaces it is zero.
sysObjectID -- sysObjectID of the unit.
sysName -- sysName of the unit.
"
::= 3
snmpAgentAuthTrapInfo-ces OBJECT IDENTIFIER
::= {snmpAgentTrapInfo-ces 1}
snmpAuthenOperation-ces OBJECT-TYPE
SYNTAX INTEGER {
getRequest(160),
getNextRequest(161),
setRequest(163),
getBulkRequest(165)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "SNMP operation attempted."
::= {snmpAgentAuthTrapInfo-ces 1}
snmpAuthenIpAddress-ces OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "IP address of host trying to access the CES."
::= {snmpAgentAuthTrapInfo-ces 2}
snmpAuthenCommString-ces OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Community string used to access the CES."
::= {snmpAgentAuthTrapInfo-ces 3}
authenticationFailure TRAP-TYPE
ENTERPRISE snmp
VARIABLES {
snmpAuthenOperation-ces,
snmpAuthenIpAddress-ces,
snmpAuthenCommString-ces,
sysObjectID,
sysName
}
DESCRIPTION
"An authenticationFailure trap signifies that the SNMPv2
entity, acting in an agent role, has received a protocol
message that is not properly authenticated.
The snmpEnableAuthenTraps object indicates
whether this trap will be generated.
snmpAuthenOperation-ces identifies the operation( ie. GetRequest,
GetNextRequest,... ) was being attempted.
snmpAuthenIpAddress-ces identifies the source IP address of
the operation.
snmpAuthenCommString-ces identifies the community string that
was used in the operation."
::= 5
snmpAgentFirewallInfo-ces OBJECT IDENTIFIER
::= {snmpAgentTrapInfo-ces 3}
firewallPolicyType-ces OBJECT-TYPE
SYNTAX FirewallPolicyType-ces
ACCESS read-only
STATUS mandatory
DESCRIPTION "Policy type."
::= {snmpAgentFirewallInfo-ces 1}
firewallRuleType-ces OBJECT-TYPE
SYNTAX FirewallRuleType-ces
ACCESS read-only
STATUS mandatory
DESCRIPTION "Type of rule that triggered this event."
::= {snmpAgentFirewallInfo-ces 2}
firewallRuleNumber-ces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Number of the rule that triggered this event."
::= {snmpAgentFirewallInfo-ces 3}
firewallSrcAddr-ces OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "Source IP address of the packet."
::= {snmpAgentFirewallInfo-ces 6}
firewallSrcPort-ces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Source port address of the packet."
::= {snmpAgentFirewallInfo-ces 7}
firewallDestAddr-ces OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "Destination IP address of the packet."
::= {snmpAgentFirewallInfo-ces 8}
firewallDestPort-ces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Destination port of the packet."
::= {snmpAgentFirewallInfo-ces 9}
firewallProtocolID-ces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The value of the protocol field in the IP header."
::= {snmpAgentFirewallInfo-ces 10}
firewallRuleAction-ces OBJECT-TYPE
SYNTAX FirewallRuleAction-ces
ACCESS read-only
STATUS mandatory
DESCRIPTION "Action defined for the triggered rule."
::= {snmpAgentFirewallInfo-ces 11}
firewallRuleTriggeredTrap TRAP-TYPE
ENTERPRISE snmpAgentFirewallInfo-ces
VARIABLES {
firewallPolicyType-ces, -- Policy type.
firewallRuleType-ces, -- Type of rule that triggered this event.
firewallRuleNumber-ces, -- Number of the rule that triggered this event.
ifIndex, -- ifIndex is the index into the ifTable for port that received the packet.
ifName-ces, -- The name of the interface, same as ifName.
firewallSrcAddr-ces, -- Source IP address of the packet.
firewallSrcPort-ces, -- Source port address of the packet.
firewallDestAddr-ces, -- Destination IP address of the packet.
firewallDestPort-ces, -- Destination port of the packet.
firewallProtocolID-ces, -- The value of the protocol field in the IP header.
firewallRuleAction-ces, -- Action defined for the triggered rule.
sysObjectID,
sysName
}
DESCRIPTION
"An event sent at the user's request to signal that a rule has
been matched.
firewallPolicyType-ces -- Policy type.
firewallRuleType-ces -- Type of rule that triggered this event.
firewallRuleNumber-ces -- Number of the rule that triggered this event.
ifIndex -- ifIndex is the index into the ifTable for port that received the packet.
ifName-ces -- The name of the interface, same as ifName.
firewallSrcAddr-ces -- Source IP address of the packet.
firewallSrcPort-ces -- Source port address of the packet.
firewallDestAddr-ces -- Destination IP address of the packet.
firewallDestPort-ces -- Destination port of the packet.
firewallProtocolID-ces -- The value of the protocol field in the IP header.
firewallRuleAction-ces -- Action defined for the triggered rule.
"
::= 1
END