snmp_mib_archive/ONS15501-MIB.my
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

1427 lines
41 KiB
Plaintext

ONS15501-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
enterprises, Integer32, Unsigned32, IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString, TimeStamp, DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
PhysicalIndex
FROM ENTITY-MIB;
ons15501MIB MODULE-IDENTITY
LAST-UPDATED "200208291600Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-dwdm@cisco.com"
DESCRIPTION
"The MIB definitions for ONS-15501 Optical
Amplifier."
REVISION "200208291600Z"
DESCRIPTION
"The MIB definition for software release 4.0 of
ONS15501. This release adds support for the AC model.
Changes to the MIB include
1. The power supply status attributes (2 new attributes)
2. New OIDs for AC chassis and AC power supplies and system
3. Object groups have been modified
4. Conformance statements changed
5. ons15501SysSwDownload expanded to support abort
6. Definitions added for ons15501SysDateAndTime object
"
REVISION "200203181230Z"
DESCRIPTION
"The first release for the MIB."
::= { synEmbLx 11 }
synchronous OBJECT IDENTIFIER ::= { enterprises 1869 }
synEmbLx OBJECT IDENTIFIER ::= { synchronous 11 }
ons15501Sys OBJECT IDENTIFIER ::= { ons15501MIB 1 }
ons15501Attr OBJECT IDENTIFIER ::= { ons15501MIB 2 }
ons15501Alarms OBJECT IDENTIFIER ::= { ons15501MIB 3 }
ons15501Notification OBJECT IDENTIFIER ::= { ons15501MIB 4 }
ons15501OIDs OBJECT IDENTIFIER ::= { ons15501MIB 5 }
ons15501MIBConformance OBJECT IDENTIFIER ::= { ons15501MIB 6 }
-- OID definitions for the agent
-- value returned for sysObjectID
ons15501OIDSystem OBJECT IDENTIFIER ::= { ons15501OIDs 1 }
ons15501OIDSystemAC OBJECT IDENTIFIER ::= { ons15501OIDs 3 }
-- value returned for entPhysicalVendorType
ons15501OIDEntity OBJECT IDENTIFIER ::= { ons15501OIDs 2 }
-- The chassis OID is applicable to ONS15501 DC
ons15501OIDChasiss OBJECT IDENTIFIER ::= { ons15501OIDEntity 1 }
ons15501OIDInPort OBJECT IDENTIFIER ::= { ons15501OIDEntity 2 }
ons15501OIDOutPort OBJECT IDENTIFIER ::= { ons15501OIDEntity 3 }
-- The power supply OID is applicable to ONS15501 DC
ons15501OIDPowerSupply OBJECT IDENTIFIER ::= { ons15501OIDEntity 4 }
-- ons15501OIDChassisAC is applicable to ONS15501 AC
ons15501OIDChassisAC OBJECT IDENTIFIER ::= { ons15501OIDEntity 5 }
-- The power supply OID is applicable to ONS15501 AC
ons15501OIDPowerSupplyAC OBJECT IDENTIFIER
::= { ons15501OIDEntity 6 }
-- From version 4.0 onwards the power supply is modeled as
-- two different physical entities
-- Textual Conventions
Ons15501ImageDnLoadStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The operational states for software image download.
This enumerates all possible failure conditions."
SYNTAX INTEGER {
notInitiated(1),
inProgress(2),
failedUnknownErr(3),
failedFileNotFound(4),
failedAccessDenied(5),
failedTimedOut(6),
completedSuccessfully(7),
failedInDownload(8), -- flash corrupted
failedTimeoutInDownload(9), -- flash corrupted
failedToConnectToServer(10),
failedWhileWritingToFlash(11), -- flash maybe corrupted
failedIllegalOperation(12), -- flash maybe corrupted
failedFileExists(13), -- flash maybe corrupted
failedUnknownTransferId(14), -- flash maybe corrupted
failedUnknownUser(15)
}
Ons15501AdminStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Administrative state for a configured object."
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
Ons15501NTPStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The operational state for NTP client.
It may be 'unknown' if the NTP client has just started."
SYNTAX INTEGER {
disabled(1),
bothServersBad(2),
usingPrimary(3),
usingSecondary(4),
unknown(5)
}
Ons15501TenthVolt ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents voltage levels that are normally
expressed in volts. Units are in tenths of a volt;
for example, -48.1 volts will be represented as -481."
SYNTAX Integer32(-1000..0)
Ons15501TenthdB ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents power levels (or power gain)
that are normally expressed in dBm (dB). Units are in
tenths of a dBm (db);
for example, -5.1 dB will be represented as -51"
SYNTAX Integer32(-1000..500)
Ons15501TenthCentigrade ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents temperature values that
are normally expressed in Centigrade. Units are in
tenths of a Centigrade;
for example, -5.1 Centigrade will be represented as -51."
SYNTAX Integer32(-500..1000)
Ons15501AlarmStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a alarm level"
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
info(4),
noAlarm(5)
}
Ons15501TrapTypeEnumeration ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This provides the details on type of alarm
none
- No exception
unacceptableAmbientTemperature,
- the temperature measured by thermal sensor
shows value outside the operational limits.
unacceptableElectricalPower,
- the measured power supply level(s) are not
within range.
inputSignalPowerTooLow,
- the measured input signal power is not
within range.
unacceptableOutputSignalPower,
- the measured output signal power is not
within range.
embeddedControllerCommFailure,
- the communication with embedded controller
has failed.
softwareUpgradeInitiated,
- a TFTP/FTP request has been launched
softwareUpgradeFailed,
- a TFTP/FTP request that was launched has failed
softwareUpgradeCompleted,
- a TFTP/FTP request that was launched has completed
softwareRebootInitiated,
- a reboot has been requested on the unit
softwareRolledBack,
- the unit has booted from a bank that is not
the programmed bank. This is possibly because the
image from programmed bank was bad or because
the boot loader was explicitly asked to boot from
another bank (using the console).
configurationChanged,
- a writeable attribute has been modified (through
any of the management interface exposed by the
system - e.g. CLI. SNMP etc.)
unacceptableGain,
- equipment is unable to achieve the planned level
for gain.
laserPumpBad,
- the measured parameters for the laser show that
a laser pump has gone bad.
eEPROMBad,
- the writes / reads from EEPROM have problems.
"
SYNTAX INTEGER {
unacceptableAmbientTemperature(1),
unacceptableElectricalPower(2),
inputSignalPowerTooLow(3),
unacceptableOutputSignalPower(4),
embeddedControllerCommFailure(5),
softwareUpgradeInitiated(6),
softwareUpgradeFailed(7),
softwareUpgradeCompleted(8),
softwareRebootInitiated(9),
softwareRolledBack(10),
configurationChanged(11),
unacceptableGain(12),
laserPumpBad(13),
eEPROMBad(14),
unknown(32767)
}
Ons15501TrapDirectionEnumeration ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a alarm level"
SYNTAX INTEGER {
dontCare(1),
asserted(2),
cleared(3)
}
--- System/Software related section
ons15501SysDevFlash1Image OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the name of the software programmed on flash
bank one."
::= { ons15501Sys 1 }
ons15501SysDevFlash2Image OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the name of the software programmed on flash
bank two."
::= { ons15501Sys 2 }
ons15501SysDevFlash3Image OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the name of the software programmed on flash
bank three."
::= { ons15501Sys 3 }
ons15501SysSwDownload OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to control the image download to the flash banks.
NOTE: Read on this attribute returns the last t/ftp command,
without login/password.
For s/w release 4.0 and above, the value read back
includes the Kilo-Bytes downloaded for last download
command.
It is the size of file downloaded (in KB), if the
download has completed. If a download is in progress
this value would correspond to Kilo-Bytes successfully
downloaded so far.
For set the string syntax is one of the following
a. abort
- Aborts the current download
b. ftp:<svr-IP>:<login>:<pass>:<path>:<fName>:<flash#>[:passive]
- Download image using ftp
c. tftp:<srvr-IP>:<fName>:<flashNo>
- Download image using tftp
where
<svr-IP> - is t/ftp server name
<login> - is login to be used for ftp (default anonymous)
<pass> - password for the login name for ftp
(default - no passwd - passwd is empty string)
<path> - path to be given on ftp prompt for cd
(default - skip cd command )
<fName> - name of the file to be downloaded and burnt
to the flash - NO DEFAULTS - because the
filename is used as distinguishing versions
there are no defaults for this command.
For TFTP Path information is part of the filename
<flash#> - which flash has to be burnt [1|2|3]
NOTE: Burn to active bank fails
passive - if `passive` is specified, ftp is done using
passive mode (provided for FTP download across
firewall).
NOTE: None of the fields should contain ':' within them, as
it is used as field separator."
::= { ons15501Sys 4 }
ons15501SysDevActiveImage OBJECT-TYPE
SYNTAX Unsigned32(1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Show currently active image's bank number.
This may be different from ons15501SysConfiguredActiveImage,
if
a. The image on ons15501SysConfiguredActiveImage did not
boot properly.
b. User chose another bank during bootup, using the
serial console port.
"
::= { ons15501Sys 5 }
ons15501SysDeviceManagerList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A ',' separated list of managers that will receive the
Traps.
If a specific host should receive the traps sent from this
unit, it should be added to the list using CLI.
Up to 16 managers can be present in this list."
::= { ons15501Sys 6 }
ons15501SysSwDownloadStatus OBJECT-TYPE
SYNTAX Ons15501ImageDnLoadStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Denotes the FTP/TFTP status. Please refer to the description
of Ons15501ImageDnLoadStatus for a list of supported values"
::= { ons15501Sys 7 }
ons15501SysConfiguredImage OBJECT-TYPE
SYNTAX Unsigned32(1..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set/Show configured value for flash-bank number to be used
on reboot.
A set on this attribute will result in a reboot of the system.
To restart the system, write back the same value as the
one read from it (or from ons15501SysDevActiveImage)."
::= { ons15501Sys 8 }
ons15501CLEICode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute represents the CLEI (Common Language
Equipment Identifier) code for the ONS15501."
REFERENCE
"Bellcore Technical Reference GR-485-CORE, COMMON
LANGUAGE Equipment Processes and Guidelines, Issue 2,
October, 1995."
::= { ons15501Sys 9 }
ons15501PrimaryNTP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address for the primary NTP server."
::= { ons15501Sys 10 }
ons15501SecondaryNTP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address for the secondary NTP server."
::= { ons15501Sys 11 }
ons15501NTPAdminStatus OBJECT-TYPE
SYNTAX Ons15501AdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured administrative status for NTP."
::= { ons15501Sys 12 }
ons15501NTPOperationalStatus OBJECT-TYPE
SYNTAX Ons15501NTPStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status for NTP."
::= { ons15501Sys 13 }
ons15501ActiveSoftwareVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute provides the active software version.
This will be same as the entPhysicalSoftwareRev for
the entry corresponding to the chassis."
::= { ons15501Sys 14 }
ons15501LastConfigChangeTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when last configuration
change was done.
NMS may use this information to synchronize if
some configuration has changed on the unit."
::= { ons15501Sys 15 }
-- The input link remote end details
ons15501InRemoteInfoUpdateTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute gives the time-stamp when one or more of
ons15501InRemoteChassisName, ons15501InRemotePortName,
or ons15501InRemoteAgentIpAddr was changed.
NMS may use this information to find the latest
information if data from remote unit does not match
that of this unit."
::= { ons15501Sys 16 }
ons15501InRemoteChassisName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manager initialized string value to identify the
chassis associated with remote connection for
optical input.
ons15501InRemoteChassisName would be a ZERO length
string if the input link is disabled.
To disable the input link details set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0."
::= { ons15501Sys 17 }
ons15501InRemotePortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical input.
ons15501InRemotePortName would be a ZERO length
string if the input link is disabled.
To disable the input link details set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0."
::= { ons15501Sys 18 }
ons15501InRemoteAgentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
providing optical input.
ons15501InRemoteAgentIpAddr would be a 0.0.0.0
if the input link is disabled.
To disable the input link entry set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0."
::= { ons15501Sys 19 }
-- The output link remote end details
ons15501OutRemoteInfoUpdateTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute gives the time-stamp when one or more of
ons15501OutRemoteChassisName, ons15501OutRemotePortName,
or ons15501OutRemoteAgentIpAddr was changed.
NMS may use this information to find the latest
information if data from remote unit does not match
that of this unit."
::= { ons15501Sys 20 }
ons15501OutRemoteChassisName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manager initialized string value to identify the
chassis associated with remote connection for
optical output.
ons15501OutRemoteChassisName would be a ZERO length
string if the output link is disabled.
To disable the output link details set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0."
::= { ons15501Sys 21 }
ons15501OutRemotePortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical output.
ons15501OutRemotePortName would be a ZERO length
string if the output link is disabled.
To disable the output link details set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0."
::= { ons15501Sys 22 }
ons15501OutRemoteAgentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
using optical output.
ons15501OutRemoteAgentIpAddr would be a 0.0.0.0
if the output link is disabled.
To disable the output link entry set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0."
::= { ons15501Sys 23 }
ons15501SysAlarmStatus OBJECT-TYPE
SYNTAX Ons15501AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides the highest severity alarm currently active."
::= { ons15501Sys 24 }
ons15501SysDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The date and time of the System.
The write will not succeed if the administrative
state for NTP (ons15501NTPAdminStatus)
is 'enabled'.
Setting this attribute will autmatically change
values for ons15501TrapLogEntryDateAndTime and
ons15501ActAlarmDateAndTime."
::= { ons15501Sys 25 }
-- Trap log table and active alarm table
ons15501LastTrapIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ons15501TrapLogEntryIndex, used while logging
the most recent trap. Goes back to 1, after reaching
the max value.
The trap log table is a circular list with the most
recent entry at index given by this attribute.
On restart of the unit, the value is reset to 1."
::= { ons15501Alarms 1 }
-- Logs
ons15501TrapLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ons15501TrapLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for last N traps (N = 100 in most cases).
Please refer to ons15501LastTrapIndex for
details on how this table is organized."
::= { ons15501Alarms 2 }
ons15501TrapLogEntry OBJECT-TYPE
SYNTAX Ons15501TrapLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for a trap"
INDEX
{ ons15501TrapLogEntryIndex }
::= { ons15501TrapLogTable 1 }
Ons15501TrapLogEntry ::= SEQUENCE {
ons15501TrapLogEntryIndex Unsigned32,
ons15501TrapLogEntryTrapType Ons15501TrapTypeEnumeration,
ons15501TrapLogEntryDirection Ons15501TrapDirectionEnumeration,
ons15501TrapLogEntryTimeStamp TimeStamp,
ons15501TrapLogEntryDateAndTime DateAndTime,
ons15501TrapLogEntryPhyIndex PhysicalIndex,
ons15501TrapLogEntrySeverity Ons15501AlarmStatus
}
ons15501TrapLogEntryIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..32767)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"index field for this entry. Actual range at
run time is ons15501TrapCounter to
ons15501TrapCounter - N + 1 or 1
(whichever is higher)"
::= { ons15501TrapLogEntry 1 }
ons15501TrapLogEntryTrapType OBJECT-TYPE
SYNTAX Ons15501TrapTypeEnumeration
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of trap. See the definition
of Ons15501TrapTypeEnumeration for possible values."
::= { ons15501TrapLogEntry 2 }
ons15501TrapLogEntryDirection OBJECT-TYPE
SYNTAX Ons15501TrapDirectionEnumeration
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the trap is being asserted or cleared.
Please note that some traps don't have a direction.
(e.g. configuration changed)."
::= { ons15501TrapLogEntry 3 }
ons15501TrapLogEntryTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the entry was placed in
the log."
::= { ons15501TrapLogEntry 4 }
ons15501TrapLogEntryDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local date and time at which the entry was placed in
the log."
::= { ons15501TrapLogEntry 5 }
ons15501TrapLogEntryPhyIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides entPhysicalIndex value for the physical entity
corresponding to the trap entry."
::= { ons15501TrapLogEntry 6 }
ons15501TrapLogEntrySeverity OBJECT-TYPE
SYNTAX Ons15501AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides the severity level corresponding to this
trap entry."
::= { ons15501TrapLogEntry 7 }
-- Active Alarms
ons15501ActiveAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ons15501ActiveAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for currently active alarm conditions.
This table is effectively the list of traps
that have been asserted but not cleared."
::= { ons15501Alarms 3 }
ons15501ActiveAlarmEntry OBJECT-TYPE
SYNTAX Ons15501ActiveAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for an active alarm condition.
For each alarm condition present on the
equipment, there would be an entry in
the table."
INDEX
{ ons15501ActAlarmType }
::= { ons15501ActiveAlarmTable 1 }
Ons15501ActiveAlarmEntry ::= SEQUENCE {
ons15501ActAlarmType Ons15501TrapTypeEnumeration,
ons15501ActAlarmTimeStamp TimeStamp,
ons15501ActAlarmDateAndTime DateAndTime,
ons15501ActAlarmPhyIndex PhysicalIndex,
ons15501ActAlarmSeverity Ons15501AlarmStatus
}
ons15501ActAlarmType OBJECT-TYPE
SYNTAX Ons15501TrapTypeEnumeration
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index field for ons15501ActiveAlarmTable.
Presence of an entry implies that the specific
alarm type is active on the unit."
::= { ons15501ActiveAlarmEntry 1 }
ons15501ActAlarmTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time since when the alarm is active."
::= { ons15501ActiveAlarmEntry 2 }
ons15501ActAlarmDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local date and time since when the alarm is active"
::= { ons15501ActiveAlarmEntry 3 }
ons15501ActAlarmPhyIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides entPhysicalIndex value for the physical entity
corresponding to the alarm entry."
::= { ons15501ActiveAlarmEntry 4 }
ons15501ActAlarmSeverity OBJECT-TYPE
SYNTAX Ons15501AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides the severity level corresponding to this
alarm entry."
::= { ons15501ActiveAlarmEntry 5 }
-- TrapType to text info maps
ons15501TrapDescriptionTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ons15501TrapDescriptionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for mapping the Ons15501TrapTypeEnumeration
values to their textual information."
::= { ons15501Alarms 4 }
ons15501TrapDescriptionEntry OBJECT-TYPE
SYNTAX Ons15501TrapDescriptionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for textual information about traps."
INDEX
{ ons15501TrapTypeValue }
::= { ons15501TrapDescriptionTable 1 }
Ons15501TrapDescriptionEntry ::= SEQUENCE {
ons15501TrapTypeValue Ons15501TrapTypeEnumeration,
ons15501TrapDescription DisplayString,
ons15501TrapSeverity Ons15501AlarmStatus
}
ons15501TrapTypeValue OBJECT-TYPE
SYNTAX Ons15501TrapTypeEnumeration
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index field for this entry."
::= { ons15501TrapDescriptionEntry 1 }
ons15501TrapDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The textual information corresponding to the
ons15501TrapTypeValue."
::= { ons15501TrapDescriptionEntry 2 }
ons15501TrapSeverity OBJECT-TYPE
SYNTAX Ons15501AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides the default severity level corresponding
to the ons15501TrapTypeValue."
::= { ons15501TrapDescriptionEntry 3 }
-- Notification
ons15501NotificationPrefix OBJECT IDENTIFIER
::= { ons15501Notification 0 }
ons15501GenericNotificationTrap NOTIFICATION-TYPE
OBJECTS {
ons15501LastTrapIndex,
ons15501TrapLogEntryTrapType,
ons15501TrapLogEntryDirection,
ons15501TrapLogEntryPhyIndex,
ons15501TrapLogEntrySeverity }
STATUS current
DESCRIPTION
"This notification is generated whenever a bitmap change is
observed on any of the monitored equipment, or when a change
has to be notified."
::= { ons15501NotificationPrefix 1 }
-- the attributes for Sensors/Amplifiers/Attenuators
ons15501InputOpticalPower OBJECT-TYPE
SYNTAX Ons15501TenthdB
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power being fed into the Amplifier."
::= { ons15501Attr 1 }
ons15501InputOpticalPowerMean OBJECT-TYPE
SYNTAX Ons15501TenthdB (-100..0)
UNITS "dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mean value for input optical power.
If the input optical power falls below
the mean value by more than trigger
(see ons15501InputOpticalPowerTrigger) an alarm
is generated. The alarm is cleared when the
input optical power is back within 90% of trigger
from the mean."
::= { ons15501Attr 2 }
ons15501InputOpticalPowerTrigger OBJECT-TYPE
SYNTAX Ons15501TenthdB (0..200)
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
input optical power falls back within 90% of the
trigger value from the mean. Please also refer
to ons15501InputOpticalPowerMean above. "
::= { ons15501Attr 3 }
ons15501OutputOpticalPower OBJECT-TYPE
SYNTAX Ons15501TenthdB
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured value for raw optical power being
generated at the output of the Amplifier."
::= { ons15501Attr 4 }
ons15501OutputSignalPower OBJECT-TYPE
SYNTAX Ons15501TenthdB
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical signal power at the output of the Amplifier.
The value of this attribute triggers the alarm, based on
mean value and trigger as defined by
ons15501OutputSignalPowerMean and
ons15501OutputSignalPowerTrigger.
This value is internally calculated using the following
formula.
ons15501OutputSignalPower = ons15501OpticalPowerGain +
ons15501InputOpticalPower
At very low ons15501InputOpticalPower (below -16 dBm),
the ons15501OutputSignalPower has significant difference
from ons15501OutputOpticalPower while at higher input
power (ons15501InputOpticalPower) they are closer.
Following graph captures the difference (for a 17 dBm
EDFA)
(dashes '-'/'_' denote optical output power
while dots '.' denote signal output power)
^
| .-
| .-
| .-
+5 dBm | .-
| .-
Optical | _.-
power / | _ -.
Signal |_ _ - .
power | .
| .
| .
-17 dBm +-----------------------+-------------->
-29 dBm -10 dBm
Input Optical Power
"
::= { ons15501Attr 5 }
ons15501OutputSignalPowerMean OBJECT-TYPE
SYNTAX Ons15501TenthdB (-60..0)
UNITS "dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mean value for output optical power.
If the output signal power falls below (or goes
above) the mean value by more than trigger
(see ons15501OutputSignalPowerTrigger) an alarm
is generated. The alarm is cleared when the
output optical power is back within 90% of trigger
from the mean."
::= { ons15501Attr 6 }
ons15501OutputSignalPowerTrigger OBJECT-TYPE
SYNTAX Ons15501TenthdB (0..180)
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
output signal power falls back within 90% of the
trigger value from the mean. Please also refer
to ons15501OutputSignalPowerMean above. "
::= { ons15501Attr 7 }
ons15501ConfigOpticalGain OBJECT-TYPE
SYNTAX Ons15501TenthdB (70..175)
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured value for power gain."
::= { ons15501Attr 8 }
ons15501OpticalPowerGain OBJECT-TYPE
SYNTAX Ons15501TenthdB
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured value for power gain.
This value does not include the amplification
noise that is significant for low input signals."
::= { ons15501Attr 9 }
ons15501GainTrigger OBJECT-TYPE
SYNTAX Ons15501TenthdB (0..20)
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gain deviation allowed from the configured gain
before an alarm is asserted. The alarm is not cleared,
until measured gain(ons15501OpticalPowerGain) is back
within 90% of ons15501GainTrigger from configured gain
(ons15501ConfigOpticalGain). "
::= { ons15501Attr 10 }
ons15501PowerSupply1Level OBJECT-TYPE
SYNTAX Ons15501TenthVolt
UNITS "volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage fed through power supply 1.
The value of the attribute is 10 times the
the value in volts."
::= { ons15501Attr 11 }
ons15501PowerSupply2Level OBJECT-TYPE
SYNTAX Ons15501TenthVolt
UNITS "volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage fed through power supply 2.
The value of the attribute is 10 times the
the value in volts."
::= { ons15501Attr 12 }
ons15501LaserStatus OBJECT-TYPE
SYNTAX Ons15501AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the status of the laser pumps."
::= { ons15501Attr 13 }
ons15501DevAmbTemp OBJECT-TYPE
SYNTAX Ons15501TenthCentigrade
UNITS "degrees C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ambient temperature for the device. "
::= { ons15501Attr 14 }
ons15501DevAmbTempMean OBJECT-TYPE
SYNTAX Ons15501TenthCentigrade (200..400)
UNITS "degrees C"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mean value for temperature.
If the temperature falls below (or goes above) the
mean value by more than trigger level (see
ons15501DevAmbTempTrigger) an alarm is generated.
The alarm is cleared when the temperature is back
within 90% of trigger value, from the mean. "
::= { ons15501Attr 15 }
ons15501DevAmbTempTrigger OBJECT-TYPE
SYNTAX Ons15501TenthCentigrade (200..300)
UNITS "degrees C"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Please refer to ons15501DevAmbTempMean above.
Trigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
temperature falls back within 90% of the value. "
::= { ons15501Attr 16 }
ons15501PowerSupply1Status OBJECT-TYPE
SYNTAX Ons15501AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the status of power supply one."
::= { ons15501Attr 17 }
ons15501PowerSupply2Status OBJECT-TYPE
SYNTAX Ons15501AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the status of power supply two."
::= { ons15501Attr 18 }
-- conformance information and compliance statements
ons15501MIBCompliances
OBJECT IDENTIFIER ::= { ons15501MIBConformance 1 }
ons15501MIBGroups
OBJECT IDENTIFIER ::= { ons15501MIBConformance 2 }
ons15501FinalCompliance MODULE-COMPLIANCE
STATUS deprecated -- superceded by ons15501Rel4Compliance
DESCRIPTION
"The compliance statement for final release ONS15501."
MODULE
MANDATORY-GROUPS { ons15501SysInfoGroup,
ons15501FinalAttrGroup,
ons15501TrapLogGroup,
ons15501ActiveAlarmGroup,
ons15501TrapDescriptionGroup,
ons15501FinalNotificationsGroup }
::= { ons15501MIBCompliances 1 }
ons15501Rel4Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for 4.0 release ONS15501."
MODULE
MANDATORY-GROUPS { ons15501SysInfoGroup2,
ons15501CoreAttrGroup,
ons15501TrapLogGroup,
ons15501ActiveAlarmGroup,
ons15501TrapDescriptionGroup,
ons15501FinalNotificationsGroup }
GROUP ons15501PowerSupplyStatusGroup
DESCRIPTION
"The status of power supply is available only for
software version 4.0 and above."
GROUP ons15501PowerSupplyLevelGroup
DESCRIPTION
"The level of power supply is available only for
the DC series of ONS15501."
::= { ons15501MIBCompliances 2 }
ons15501SysInfoGroup OBJECT-GROUP
OBJECTS {
ons15501SysDevFlash1Image,
ons15501SysDevFlash2Image,
ons15501SysDevFlash3Image,
ons15501SysSwDownload,
ons15501SysSwDownloadStatus,
ons15501SysConfiguredImage,
ons15501SysDevActiveImage,
ons15501SysAlarmStatus,
ons15501PrimaryNTP,
ons15501SecondaryNTP,
ons15501NTPAdminStatus,
ons15501NTPOperationalStatus,
ons15501CLEICode,
ons15501InRemoteInfoUpdateTime,
ons15501InRemoteChassisName,
ons15501InRemotePortName,
ons15501InRemoteAgentIpAddr,
ons15501OutRemoteInfoUpdateTime,
ons15501OutRemoteChassisName,
ons15501OutRemotePortName,
ons15501OutRemoteAgentIpAddr,
ons15501LastConfigChangeTime,
ons15501ActiveSoftwareVer,
ons15501SysDeviceManagerList
}
STATUS deprecated -- superceded by ons15501SysInfoGroup2
DESCRIPTION
"The basic group defines objects which are common to all
Embedded Linux product series of Synchronous equipment."
::= { ons15501MIBGroups 1 }
ons15501TrapLogGroup OBJECT-GROUP
OBJECTS {
ons15501LastTrapIndex,
ons15501TrapLogEntryTrapType,
ons15501TrapLogEntryDirection,
ons15501TrapLogEntryTimeStamp,
ons15501TrapLogEntryDateAndTime,
ons15501TrapLogEntryPhyIndex,
ons15501TrapLogEntrySeverity
}
STATUS current
DESCRIPTION
"The trap attribute group provides the trap logs.
These attributes are also used in trap notifications."
::= { ons15501MIBGroups 2 }
ons15501ActiveAlarmGroup OBJECT-GROUP
OBJECTS {
ons15501ActAlarmPhyIndex,
ons15501ActAlarmTimeStamp,
ons15501ActAlarmDateAndTime,
ons15501ActAlarmSeverity
}
STATUS current
DESCRIPTION
"The alarm attribute group provides the list of active
alarms"
::= { ons15501MIBGroups 3 }
ons15501TrapDescriptionGroup OBJECT-GROUP
OBJECTS {
ons15501TrapDescription,
ons15501TrapSeverity
}
STATUS current
DESCRIPTION
"The trap description attribute group provides the
mapping from trap type to textual information about
the trap."
::= { ons15501MIBGroups 4 }
ons15501FinalAttrGroup OBJECT-GROUP
OBJECTS {
ons15501InputOpticalPower,
ons15501InputOpticalPowerMean,
ons15501InputOpticalPowerTrigger,
ons15501OutputOpticalPower,
ons15501OutputSignalPower,
ons15501OutputSignalPowerMean,
ons15501OutputSignalPowerTrigger,
ons15501ConfigOpticalGain,
ons15501OpticalPowerGain,
ons15501PowerSupply1Level,
ons15501PowerSupply2Level,
ons15501DevAmbTemp,
ons15501DevAmbTempMean,
ons15501DevAmbTempTrigger,
ons15501LaserStatus,
ons15501GainTrigger
}
STATUS deprecated -- superceded by ons15501CoreAttrGroup
DESCRIPTION
"The ons15501 group of attributes models the parameters
in the EDFA."
::= { ons15501MIBGroups 5 }
ons15501FinalNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { ons15501GenericNotificationTrap }
STATUS current
DESCRIPTION
"The notification that carries all the exception
information."
::= { ons15501MIBGroups 6 }
ons15501CoreAttrGroup OBJECT-GROUP
OBJECTS {
ons15501InputOpticalPower,
ons15501InputOpticalPowerMean,
ons15501InputOpticalPowerTrigger,
ons15501OutputOpticalPower,
ons15501OutputSignalPower,
ons15501OutputSignalPowerMean,
ons15501OutputSignalPowerTrigger,
ons15501ConfigOpticalGain,
ons15501OpticalPowerGain,
ons15501DevAmbTemp,
ons15501DevAmbTempMean,
ons15501DevAmbTempTrigger,
ons15501LaserStatus,
ons15501GainTrigger
}
STATUS current
DESCRIPTION
"The ons15501 group of attributes models the parameters
in the EDFA. The power supply related attributes are
not part of this group."
::= { ons15501MIBGroups 7 }
ons15501PowerSupplyStatusGroup OBJECT-GROUP
OBJECTS {
ons15501PowerSupply1Status,
ons15501PowerSupply2Status
}
STATUS current
DESCRIPTION
"The ons15501 group of attributes models the status
of power supplies. The support for status was introduced
in version 4.0."
::= { ons15501MIBGroups 8 }
ons15501PowerSupplyLevelGroup OBJECT-GROUP
OBJECTS {
ons15501PowerSupply1Level,
ons15501PowerSupply2Level
}
STATUS current
DESCRIPTION
"The ons15501 group of attributes provides the
voltage level of power supplies. It is available only
for DC series of ONS15501."
::= { ons15501MIBGroups 9 }
ons15501SysInfoGroup2 OBJECT-GROUP
OBJECTS {
ons15501SysDevFlash1Image,
ons15501SysDevFlash2Image,
ons15501SysDevFlash3Image,
ons15501SysSwDownload,
ons15501SysSwDownloadStatus,
ons15501SysConfiguredImage,
ons15501SysDevActiveImage,
ons15501SysAlarmStatus,
ons15501PrimaryNTP,
ons15501SecondaryNTP,
ons15501NTPAdminStatus,
ons15501NTPOperationalStatus,
ons15501CLEICode,
ons15501InRemoteInfoUpdateTime,
ons15501InRemoteChassisName,
ons15501InRemotePortName,
ons15501InRemoteAgentIpAddr,
ons15501OutRemoteInfoUpdateTime,
ons15501OutRemoteChassisName,
ons15501OutRemotePortName,
ons15501OutRemoteAgentIpAddr,
ons15501LastConfigChangeTime,
ons15501ActiveSoftwareVer,
ons15501SysDeviceManagerList,
ons15501SysDateAndTime
}
STATUS current
DESCRIPTION
"The basic group defines objects which are common to all
Embedded Linux product series of Synchronous equipment."
::= { ons15501MIBGroups 10 }
END