-- CISCO-VOICE-ANALOG-IF-MIB.my: Voice Analog Interface MIB file
--
-- September 1996 Hongchi Shih
--
-- Copyright (c) 1996-1997, 2001-2004 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
CISCO-VOICE-ANALOG-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32,
Counter32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
ifIndex
FROM IF-MIB
ciscoMgmt
FROM CISCO-SMI;
ciscoVoiceAnalogIfMIB MODULE-IDENTITY
LAST-UPDATED "200510030000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" Cisco Systems
Customer Service
Postal: 170 W. Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-voice@cisco.com"
DESCRIPTION
"Analog Voice Interface MIB module.
This MIB manages the E&M, FXO, FXS
Interfaces in the router.
"
REVISION "200510030000Z"
DESCRIPTION
"Extend cvaIfEMCfgSignalType to include
fgd(5) and fgd-eana(6)
"
REVISION "200410140000Z"
DESCRIPTION
"Extend CvaIfEMCfgEntry to include
cvaIfEMCfgAutoGainControl
Extend CvaIfEMTimingEntry to include
cvaIfEMTimeoutPttXmt
cvaIfEMTimeoutPttRcv
cvaIfEMTimingDelayVoice
add cvaIfEMGroupRev2
"
REVISION "200401150000Z"
DESCRIPTION
"Extend cvaIfEMCfgSignalType to include
lmr(4)
Extend CvaIfEMCfgEntry to include
cvaIfEMCfgLmrMCap & cvaIfEMCfgLmrECap
Extend CvaIfEMTimingEntry to include
cvaIfEMTimingVoiceHangover &
cvaIfEMTimeoutLmrTeardown
Deprecated cvaIfEMGroup
add cvaIfEMGroupRev1
Addition of fxoCama in cvaIfFXOCfgSignalType.
Deprecated cvaIfFXOCfgSupDisconnect in favor of
cvaIfFXOCfgSupDisconnect2.
Add cvaIfMIBCompliance2
"
REVISION "200208030000Z"
DESCRIPTION
"Addition of fxoCama in cvaIfFXOCfgSignalType.
"
REVISION "200207290000Z"
DESCRIPTION
"Deprecated cvaIfFXOCfgSupDisconnect in favor of
cvaIfFXOCfgSupDisconnect2.
"
REVISION "200201210000Z"
DESCRIPTION
"Created TC InterfaceDialType. Updated
cvaIfEMCfgDialType and cvaIfFXOCfgDialType
objects to use this TC InterfaceDialType.
Added enumeration 'trunked(3)' to the SYNTAX of
cvaIfFXSHookStatus.
Added enumeration 'trunked(3)' to the SYNTAX of
cvaIfFXOHookStatus.
"
::= { ciscoMgmt 62 }
--
-- Overview of Analog Voice interface MIB
--
-- The Analog Voice interface MIB provides the standard configuration,
-- timing parameters and telephony hook, ring status information on Cisco's
-- Analog Voice interface implementation. The following groups
-- are managed:
-- 1) Analog interface general group
-- 2) E&M (recEive and transMit) interface group
-- 3) FXO (Foreign Exchange Office) interface group
-- 4) FXS (Foreign Exchange Station) interface group
--
-- ifEntry for an Analog Voice Interface
--
-- The ifEntry for an Analog Voice Interface supports the
-- ifGeneralInformationGroup of Cisco IF-MIB.
-- ifTable Comments
-- ============== =====================================================
-- ifIndex Each Analog telephony interface is represented by an
-- ifEntry.
-- ifDescr Textual port description.
-- ifType The IANA value of voiceEM(100), voiceFXO(101) and
-- voiceFXS(102).
-- ifSpeed contains a zero value.
-- ifPhysAddress contains an octet string of zero length.
--
-- ifAdminStatus The desired administrative status of the
-- Analog Telephony interface port.
-- ifOperStatus The current operational status of the Analog Telephony
-- interface port. Note that dormant(5) is explicitly being
-- used as defined in RFC 1573.
-- ifLastChange Refer to RFC 1573.
-- ifLinkUpDownTrapEnable
-- Refer to RFC 1573.
-- ifConnectorPresent
-- Refer to RFC 1573.
-- ifHighSpeed contains a zero value.
-- ifName Refer to RFC 1573.
-- ifAlias Refer to Cisco IF-MIB.
--
--
-- Relationship to the IETF Dial Control MIB (RFC2128)
--
-- Associating and disassociating an analog voice interface with
-- a connection can be explicitly handled using an ifStack. If a
-- call connection is established, the managed system correlates the call
-- associated voice encapsulation interface with the analog voice interface
-- via ifStack based on the section 2.2.1 of RFC2128.
cvaIfObjects OBJECT IDENTIFIER ::= { ciscoVoiceAnalogIfMIB 1 }
cvaIfGeneralObjects OBJECT IDENTIFIER ::= { cvaIfObjects 1 }
cvaIfEMObjects OBJECT IDENTIFIER ::= { cvaIfObjects 2 }
cvaIfFXOObjects OBJECT IDENTIFIER ::= { cvaIfObjects 3 }
cvaIfFXSObjects OBJECT IDENTIFIER ::= { cvaIfObjects 4 }
--
-- Textual Conventions
--
--
-- Dial Type Textual Conventions
--
InterfaceDialType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the out dialing type of E&M interface and
FXO type interfaces.
dtmf - DTMF digit.
pulse - pulse.
mf - mf digit.
"
SYNTAX INTEGER {
dtmf (1),
pulse (2),
mf (3)
}
--****************************************************************************
-- The Analog Voice General Interface Group
--****************************************************************************
-- [1] Analog Voice Interface Standard Configuration Table
-- [2] Analog Voice Interface Status Table
--****************************************************************************
-- The Analog Voice Interface Standard Configuration Table
--****************************************************************************
cvaIfCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Analog Voice Standard Configuration Table. It contains
the standard configuration information of the analog
telephony interface.
"
::= { cvaIfGeneralObjects 1 }
cvaIfCfgEntry OBJECT-TYPE
SYNTAX CvaIfCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the configuration table for each voice analog
interface. The entry is created when the voice analog
hardware is detected.
"
INDEX { ifIndex }
::= { cvaIfCfgTable 1 }
CvaIfCfgEntry ::=
SEQUENCE {
cvaIfCfgImpedance INTEGER,
cvaIfCfgIntegratedDSP TruthValue
}
cvaIfCfgImpedance OBJECT-TYPE
SYNTAX INTEGER {
other (1),
ohms600Real (2),
ohms600Complex (3),
ohms900Complex (4),
ohmsComplex1 (5),
ohmsComplex2 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the terminating impedance of voice analog
interfaces.
other - none of the following; arbitrary,
within limits, for special cases.
ohms600Real - 600 Ohms.
ohms600Complex - 600 Ohms + 2.16uF
ohms900Complex - 900 Ohms + 2.16uF.
ohmsComplex1 - complex 1;
220 Ohms + 820 Ohms || 115nF.
This impedance is primarily used in
Germany.
ohmsComplex2 - complex 2;
270 Ohms + 750 Ohms || 150nF.
This impedance is primarily used in
United Kingdom and Sweden.
"
::= { cvaIfCfgEntry 1 }
cvaIfCfgIntegratedDSP OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the interface has an integrated
Digital Signal processing (DSP) unit.
"
::= { cvaIfCfgEntry 2 }
--****************************************************************************
-- The Analog Voice Interface Status Table
--****************************************************************************
cvaIfStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Analog Voice Status Table. It contains general
information about the status of Analog Telephony interface
including the error statistics.
"
::= { cvaIfGeneralObjects 2 }
cvaIfStatusEntry OBJECT-TYPE
SYNTAX CvaIfStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the status table for each Analog voice interface.
"
AUGMENTS { cvaIfCfgEntry }
::= { cvaIfStatusTable 1 }
CvaIfStatusEntry ::=
SEQUENCE {
cvaIfStatusInfoType INTEGER,
cvaIfMaintenanceMode INTEGER,
cvaIfStatusSignalErrors Counter32
}
cvaIfStatusInfoType OBJECT-TYPE
SYNTAX INTEGER {
none (1),
voice(2),
g3Fax(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The information transfer services for the current
or last call.
none - no information transfer service
voice - analog voice.
g3Fax - Group 3 FAX.
"
::= { cvaIfStatusEntry 1 }
cvaIfMaintenanceMode OBJECT-TYPE
SYNTAX INTEGER {
none (1),
hostCompressedLoopback (2),
hostUncompressedLoopback (3),
ifCompressedLoopback (4),
ifUncompressedLoopback (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maintenance modes of the Analog voice interface.
Managed system
+=============+=============================+
| Voice | +===========+ telephony |
<=====+ application +===+ CODEC +===end point +=== test
IP | (Host) | . +===========+ .(Interface)| equipment
backbone +=============+=============================+
. .
Host ======>===+ .
Compressed <======+ .
. .
Host ===================>======+
Uncompressed <======================+
. .
Interface +========<==========================
Compressed +==================================>
. .
Interface . +===<===============
Uncompressed . +==================>
Compress Uncompress
Loopback Loopback
point point
none(1) - the interface is not in maintenance mode.
hostCompressedLoopback(2) - Host Compressed Loopback.
This mode is set by the managed system to perform the
compressed voice loopback test. The voice packet is passed
by voice application to the interface associated CODEC.
Instead of feeding these into the CODEC for decompression,
they are immediately sent back to the voice application as
if they had originated locally and been compressed.
hostUncompressedLoopback(3) - Host Uncompressed Loopback.
This mode is set by the managed system to perform the
uncompressed voice loopback test. The voice packet is
sent by voice application all the way through the
interface associated CODEC and then turned around instead
of being sent to the telephony endpoint.
ifCompressedLoopback(4) - Interface Compressed Loopback.
This mode is set by the managed system to perform the
interface uncompressed voice loopback test for the
external test equipment that is connected to the voice
interface.
The voice samples are sent from the test equipment all the
way through the interface associated CODEC and then turned
around instead of being sent to voice application.
ifUncompressedLoopback(5) - Interface Uncompressed Loopback.
This mode is set by the managed system to perform the
interface uncompressed voice loopback test for the
external test equipment that is connected to the voice
interface.
The voice samples are sent from the test equipment to the
interface associated CODEC. Instead of feeding the voice
samples into the CODEC for compression, they are
immediately sent back to the telephony interface.
"
::= { cvaIfStatusEntry 2 }
cvaIfStatusSignalErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Accumulated number of signaling protocol errors that are
detected in the interface since system startup."
::= { cvaIfStatusEntry 3 }
--****************************************************************************
-- The E&M Standard Configuration Table
--****************************************************************************
-- This table is used to configure the E&M type, signaling, operation,
-- dial type for the E&M interface.
cvaIfEMCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfEMCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The E&M standard configuration table. It contains
the current setting of E&M configurable parameters.
"
::= { cvaIfEMObjects 1 }
cvaIfEMCfgEntry OBJECT-TYPE
SYNTAX CvaIfEMCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the standard configuration table for
each E&M tie trunk interface."
INDEX { ifIndex }
::= { cvaIfEMCfgTable 1 }
CvaIfEMCfgEntry ::=
SEQUENCE {
cvaIfEMCfgSignalType INTEGER,
cvaIfEMCfgOperation INTEGER,
cvaIfEMCfgType INTEGER,
cvaIfEMCfgDialType InterfaceDialType,
cvaIfEMCfgLmrMCap INTEGER,
cvaIfEMCfgLmrECap INTEGER,
cvaIfEMCfgAutoGainControl TruthValue
}
cvaIfEMCfgSignalType OBJECT-TYPE
SYNTAX INTEGER {
winkStart (1),
immediateDial (2),
delayDial (3),
lmr (4),
fgd (5),
fgd-eana (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The signaling type of E&M tie trunk interface.
winkStart - the calling side seizes the line by going
off-hook on its E lead but waits for a short
off-hook 'wink' indication on its M lead from
the called side before sending address
information as DTMF digits.
immediateDial - the calling side seizes the line by going
off-hook on its E lead and sends sends address
information as DTMF digits.
delayDial - the calling side seizes the line by going
off-hook on its E lead. After a timing interval,
the calling side looks at the supervision
from the called side. If the supervision is
on-hook, the calling side starts sending
information as DTMF digits; otherwise, the calling
side waits until the called side goes
on-hook and then starts sending address
information.
lmr - the e&m port is used to interface with
Land Mobil Radio system. The e-lead and
m-lead are not used in the traditional
way.
fgd - Feature Group D is an access switched services
that provides access to Local Exchange Carrier
of the public switched network. It is supported
in North America only based on E&M wink-start.
fgd-eana - Exchange Access North American signalling
protocol of Feature Group D.
"
REFERENCE
"EIA/TIA-464B: Sections 4.1.3.4.1 Signaling Protocols.
"
DEFVAL { winkStart }
::= { cvaIfEMCfgEntry 1 }
cvaIfEMCfgOperation OBJECT-TYPE
SYNTAX INTEGER {
twoWires (1),
fourWires (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the operation of the E&M signal.
twoWires - 2-wire operation.
fourWires - 4-wire operation.
"
DEFVAL { twoWires }
::= { cvaIfEMCfgEntry 2 }
cvaIfEMCfgType OBJECT-TYPE
SYNTAX INTEGER {
typeI (1),
typeII (2),
typeIII (3),
typeIV (4),
typeV (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the E&M Lead Signaling type.
LEGEND: V = -48V
/\/\/ = detector/resister
X = normally open relay contact
+ = normally closed relay contact
G = ground
SB = Signal Battery
SG = Signal Ground
typeI -
Leads: E (output, relay to ground)
M (input, referenced to ground)
The tie line equipment (switch/router/etc) generates the
E-signal to the PBX type grounding the E-lead.
The tie line equipment detects the M-signal by detecting
current flow to ground. A common ground must exist
between the line equipment and the PBX.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----G
|
M: V----X-----|---/\/\/--G
typeII -
Leads: E (output, relay to SG)
M (input, referenced to ground)
SB (feed for M, connected to -48V)
SG (return for E, galvanically isolated from ground)
This interface requires no common ground between the
equipment, thus avoiding ground loop noise problems.
E-signal is generated toward the PBX by connecting it
to SG. M-signal is indicated by the PBX connecting
it to SB. While this interface does NOT require a
common ground, it does have the tendency to inject
noise into the audio paths since it is asymmetrical
with respect to current flow between devices.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----
| |
SG: G----------|----------
|
M: ----X-----|---/\/\/--G
| |
SB: ----------|----------V
typeIII -
Leads: E (output, relay to ground)
M (input, referenced to ground)
SB (connected to -48V)
SG (connected to ground)
This interface operates similar to type I with respect
to the E-signal. The M-signal, however, is indicated by
the PBX connecting it to SB on assertion, and alternately
connecting it to SG during inactivity. Unfortunately, a
common ground must be shared between the equipment.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----G
|
SG: ----------|----------G
+ |
M: ----------|---/\/\/--G
X |
SB: ----------|----------V
typeIV -
Leads: E (output, relay to SG)
M (input, referenced to -48V)
SB (feed for M, connected to ground)
SG (return for E, galvanically isolated from ground)
This interface is fully symmetrical; it does not require
a common ground, does not inject noise into audio paths,
and can be connected back to back by swapping E/SG for
M/SB. E-signal is indicated to the PBX by connecting it
to SG. M-signal is provided by the PBX connecting it to
SB.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----
| |
SG: G----------|----------
|
M: ----------|---/\/\/--V
X |
SB: ----------|----------G
typeV -
Leads: E (output, relay to ground)
M (input, referenced to -48V)
Type V line equipment indicates E-signal to the PBX by
grounding the E-lead. The PBX indicates M-signal by
grounding the M-lead. This interface does require a
common ground, but does allow back to back connections
by swapping E for M. This interface is quasi-symmetric
in that while the line is up, current flow is more or
less equal between the PBX and line equipment. But noise
injection is still a problem.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----G
|
M: G-----X----|---/\/\/--V
|
"
REFERENCE
"EIA/TIA-464B: Sections 4.2.3 E&M Lead Signaling.
"
DEFVAL { typeI }
::= { cvaIfEMCfgEntry 3 }
cvaIfEMCfgDialType OBJECT-TYPE
SYNTAX InterfaceDialType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the out dialing type of E&M interface.
"
DEFVAL { dtmf }
::= { cvaIfEMCfgEntry 4 }
cvaIfEMCfgLmrMCap OBJECT-TYPE
SYNTAX INTEGER {
inact (1),
audio (2),
dial (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The M lead behavior of E&M LMR interface.
inact - The m-lead status should be ignored.
audio - The m-lead status is used to control
generating voice packet.
dial - Perform the same audio case except abling to
initiate a call when offhook in a idle state.
"
DEFVAL { inact }
::= { cvaIfEMCfgEntry 5 }
cvaIfEMCfgLmrECap OBJECT-TYPE
SYNTAX INTEGER {
seize (4),
voice (5),
inactive (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The E lead behavior of E&M LMR interface.
seize - The e-lead used as seize signal
voice - The e-lead status is used to indicate
voice packet received or not.
inactive -- e-lead is inactive.
"
DEFVAL { seize }
::= { cvaIfEMCfgEntry 6 }
cvaIfEMCfgAutoGainControl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enabling/disabling automatic
gain control(AGC) on this interface. AGC allows DSP
to adjust the input voice volume and avoid rapid
voice volume change.
"
DEFVAL { false }
::= { cvaIfEMCfgEntry 7 }
--****************************************************************************
-- The E&M interface Status Table
--****************************************************************************
cvaIfEMStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfEMStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The E&M interface Table. The table contains
the status of the E&M tie trunk interface.
"
::= { cvaIfEMObjects 2 }
cvaIfEMStatusEntry OBJECT-TYPE
SYNTAX CvaIfEMStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the status table for each E&M interface.
"
AUGMENTS { cvaIfEMCfgEntry }
::= { cvaIfEMStatusTable 1 }
CvaIfEMStatusEntry ::=
SEQUENCE {
cvaIfEMInSeizureActive TruthValue,
cvaIfEMOutSeizureActive TruthValue
}
cvaIfEMInSeizureActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming seizure state of the E&M
interface. If the value is true, then the interface has an
incoming trunk seizure active; otherwise, it doesn't.
"
::= { cvaIfEMStatusEntry 1 }
cvaIfEMOutSeizureActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the outgoing seizure state of the E&M
interface. If the value is true, then the interface has an
outgoing trunk seizure active; otherwise, it doesn't.
"
::= { cvaIfEMStatusEntry 2 }
--****************************************************************************
-- The E&M Timing Parameters Table
--****************************************************************************
-- This table contains the E&M interface timing parameters information.
cvaIfEMTimingTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfEMTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The E&M tie trunk Timing Parameters table. It
contains the configuration of the various E&M signaling
protocol timing parameters.
"
::= { cvaIfEMObjects 3 }
cvaIfEMTimingEntry OBJECT-TYPE
SYNTAX CvaIfEMTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the E&M Timing Parameters Table for
each E&M interface."
AUGMENTS { cvaIfEMCfgEntry }
::= { cvaIfEMTimingTable 1 }
CvaIfEMTimingEntry ::=
SEQUENCE {
cvaIfEMTimingDigitDuration Integer32,
cvaIfEMTimingInterDigitDuration Integer32,
cvaIfEMTimingPulseRate Integer32,
cvaIfEMTimingPulseInterDigitDuration Integer32,
cvaIfEMTimingClearWaitDuration Integer32,
cvaIfEMTimingMaxWinkWaitDuration Integer32,
cvaIfEMTimingMaxWinkDuration Integer32,
cvaIfEMTimingDelayStart Integer32,
cvaIfEMTimingMaxDelayDuration Integer32,
cvaIfEMTimingMinDelayPulseWidth Integer32,
cvaIfEMTimingVoiceHangover Integer32,
cvaIfEMTimeoutLmrTeardown Integer32,
cvaIfEMTimeoutPttXmt Integer32,
cvaIfEMTimeoutPttRcv Integer32,
cvaIfEMTimingDelayVoice Integer32
}
cvaIfEMTimingDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF digit duration in milliseconds.
"
DEFVAL { 100 }
::= { cvaIfEMTimingEntry 1 }
cvaIfEMTimingInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF inter-digit duration in milliseconds.
"
DEFVAL { 100 }
::= { cvaIfEMTimingEntry 2 }
cvaIfEMTimingPulseRate OBJECT-TYPE
SYNTAX Integer32 (10..20)
UNITS "pulses per second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing pulse dialing rate in pulses per second (pps).
"
DEFVAL { 10 }
::= { cvaIfEMTimingEntry 3 }
cvaIfEMTimingPulseInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (100..1000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing Pulse dialing inter-digit timing in
milliseconds.
"
DEFVAL { 750 }
::= { cvaIfEMTimingEntry 4 }
cvaIfEMTimingClearWaitDuration OBJECT-TYPE
SYNTAX Integer32 (200..2000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of Inactive seizure signal to declare call cleared.
"
DEFVAL { 400 }
::= { cvaIfEMTimingEntry 5 }
cvaIfEMTimingMaxWinkWaitDuration OBJECT-TYPE
SYNTAX Integer32 (100..5000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum time to wait from the outgoing seizure of the line
to the time of sending out a wink-pulse.
"
DEFVAL { 200 }
::= { cvaIfEMTimingEntry 6 }
cvaIfEMTimingMaxWinkDuration OBJECT-TYPE
SYNTAX Integer32 (100..3000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum outgoing wink duration (between the wink-pulse leading
edge and trailing edge) for wink start signaling.
"
DEFVAL { 200 }
::= { cvaIfEMTimingEntry 7 }
cvaIfEMTimingDelayStart OBJECT-TYPE
SYNTAX Integer32 (20..2000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum time to wait from outgoing seizure to
out-dialing digits for delay start signaling.
"
DEFVAL { 300 }
::= { cvaIfEMTimingEntry 8 }
cvaIfEMTimingMaxDelayDuration OBJECT-TYPE
SYNTAX Integer32 (100..5000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum time to wait from outgoing seizure to
out-dialing digits. If the far end does not allow to
send digits after the duration specified in the object,
a reorder tone will be sent to the calling party.
"
DEFVAL { 2000 }
::= { cvaIfEMTimingEntry 9 }
cvaIfEMTimingMinDelayPulseWidth OBJECT-TYPE
SYNTAX Integer32 (0 | 140..5000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum delay-dial pulse duration for incoming call.
If the value of this object is 0, then no delay-dial
is sent to the far end for the incoming call.
"
DEFVAL { 140 }
::= { cvaIfEMTimingEntry 10 }
cvaIfEMTimingVoiceHangover OBJECT-TYPE
SYNTAX Integer32 (0..10000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hangover time used to determine the casethere is
no more voice packet arrived.
"
DEFVAL { 250 }
::= { cvaIfEMTimingEntry 11 }
cvaIfEMTimeoutLmrTeardown OBJECT-TYPE
SYNTAX Integer32 (-1 | 5..60000)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LMR port tear down timeout.
This object is relevant to the waiting time of
teardown call on LMR port.
if the value of this object is '-1', then the timeout
is disable.
"
DEFVAL { 1800 }
::= { cvaIfEMTimingEntry 12 }
cvaIfEMTimeoutPttXmt OBJECT-TYPE
SYNTAX Integer32 (0..30)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object signifies LMR port maxinum transmit time.
This object is relevant to how long LMR port can
continue transmit voice packet without pause.
"
DEFVAL { 0 }
::= { cvaIfEMTimingEntry 13 }
cvaIfEMTimeoutPttRcv OBJECT-TYPE
SYNTAX Integer32 (0..30)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object signifies LMR port maxinum receive time.
This object is relevant to how long LMR port can
continue receive voice packet without pause.
"
DEFVAL { 0 }
::= { cvaIfEMTimingEntry 14 }
cvaIfEMTimingDelayVoice OBJECT-TYPE
SYNTAX Integer32 (0..1500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is relevant to how long DSP will delay
sending the voice packet to the LMR port.
"
DEFVAL { 0 }
::= { cvaIfEMTimingEntry 15 }
--****************************************************************************
-- The Foreign Exchange Office (FXO) Standard Configuration Table
--****************************************************************************
-- This table is used to configure the FXO signaling and number of rings
-- for the FXO interface.
cvaIfFXOCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfFXOCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FXO standard configuration table. It contains
FXO configuration parameters, one entry per FXO interface.
The configuration information of this table is set by
hardware with its default setting or CLI during the hardware
installation time.
"
::= { cvaIfFXOObjects 1 }
cvaIfFXOCfgEntry OBJECT-TYPE
SYNTAX CvaIfFXOCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the standard configuration table for
each FXO interface."
INDEX { ifIndex }
::= { cvaIfFXOCfgTable 1 }
CvaIfFXOCfgEntry ::=
SEQUENCE {
cvaIfFXOCfgSignalType INTEGER,
cvaIfFXOCfgNumberRings Integer32,
cvaIfFXOCfgSupDisconnect TruthValue,
cvaIfFXOCfgDialType InterfaceDialType,
cvaIfFXOCfgSupDisconnect2 INTEGER
}
cvaIfFXOCfgSignalType OBJECT-TYPE
SYNTAX INTEGER {
fxoLoopStart (1),
fxoGroundStart (2),
fxoCama (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the signaling type of FXO interface.
fxoLoopStart - loop start.
fxoGroundStart - ground start.
fxoCama - cama.
"
DEFVAL { fxoLoopStart }
::= { cvaIfFXOCfgEntry 1 }
cvaIfFXOCfgNumberRings OBJECT-TYPE
SYNTAX Integer32 (1..10)
UNITS "rings"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of rings detected before closing loop.
"
DEFVAL { 1 }
::= { cvaIfFXOCfgEntry 2 }
cvaIfFXOCfgSupDisconnect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated -- superceded by cvaIfFXOCfgSupDisconnect2
DESCRIPTION
" Specifies whether a supervisory disconnect signal (CPC) will
be presented to the interface when the connected party at
the interface hangs up.
"
DEFVAL { true }
::= { cvaIfFXOCfgEntry 3 }
cvaIfFXOCfgDialType OBJECT-TYPE
SYNTAX InterfaceDialType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the out dialing type of FXO interface.
"
DEFVAL { dtmf }
::= { cvaIfFXOCfgEntry 4 }
cvaIfFXOCfgSupDisconnect2 OBJECT-TYPE
SYNTAX INTEGER {
signal(0),
anytone(1),
dualtoneMidcall(2),
dualtonePreconnect(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Specifies the type of supervisory disconnect signal
(CPC) to be presented to the interface when the
connected party at the interface hangs up.
signal - power denial recognition
anytone - tone detection of all call progressing tones
dualtoneMidcall - tone detection to operate throughout
the call duration
dualtonePreconnect - tone detection to operate only
during call setup
"
DEFVAL { signal }
::= { cvaIfFXOCfgEntry 5 }
--****************************************************************************
-- The Foreign Exchange Office (FXO) interface Status Table
--****************************************************************************
cvaIfFXOStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfFXOStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Foreign Exchange Office (FXO) interface Status Table.
It contains hook status, ring detection and other states of
the interface.
"
::= { cvaIfFXOObjects 2 }
cvaIfFXOStatusEntry OBJECT-TYPE
SYNTAX CvaIfFXOStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the status table for each FXO interface.
"
AUGMENTS { cvaIfFXOCfgEntry }
::= { cvaIfFXOStatusTable 1 }
CvaIfFXOStatusEntry ::=
SEQUENCE {
cvaIfFXOHookStatus INTEGER,
cvaIfFXORingDetect TruthValue,
cvaIfFXORingGround TruthValue,
cvaIfFXOTipGround TruthValue
}
cvaIfFXOHookStatus OBJECT-TYPE
SYNTAX INTEGER {
onHook (1),
offHook (2),
trunked (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the hook status of FXO interface.
onHook - Present the onHook to the connected equipment.
offHook - Present the offHook to the connected equipment.
trunked - Present the trunk to the connected equipment.
"
::= { cvaIfFXOStatusEntry 1 }
cvaIfFXORingDetect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the ring detect indication. If the
value is true, then the interface detects ring from PBX or
CO; otherwise, it doesn't."
::= { cvaIfFXOStatusEntry 2 }
cvaIfFXORingGround OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming ring ground indication.
It is only valid when the cvaIfFXOCfgSignalType is
fxoGroundStart. If the object is true, then the interface
is presenting a ring ground to the connected equipment;
otherwise, it doesn't.
"
::= { cvaIfFXOStatusEntry 3 }
cvaIfFXOTipGround OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming tip ground indication.
It is only valid when the cvaIfFXOCfgSignalType is
fxoGroundStart. If the object is true, then the interface
is detecting a tip ground at the interface; otherwise,
it doesn't.
"
::= { cvaIfFXOStatusEntry 4 }
--****************************************************************************
-- The FXO Timing Parameters Table
--****************************************************************************
-- This table contains the FXO interface timing parameters information.
cvaIfFXOTimingTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfFXOTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FXO interface Timing Parameters table. It
contains the configuration of the various FXO signaling
protocol timing parameters.
"
::= { cvaIfFXOObjects 3 }
cvaIfFXOTimingEntry OBJECT-TYPE
SYNTAX CvaIfFXOTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the FXO Timing Parameters Table for
each FXO interface."
AUGMENTS { cvaIfFXOCfgEntry }
::= { cvaIfFXOTimingTable 1 }
CvaIfFXOTimingEntry ::=
SEQUENCE {
cvaIfFXOTimingDigitDuration Integer32,
cvaIfFXOTimingInterDigitDuration Integer32,
cvaIfFXOTimingPulseRate Integer32,
cvaIfFXOTimingPulseInterDigitDuration Integer32
}
cvaIfFXOTimingDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF digit duration in milliseconds.
"
DEFVAL { 100 }
::= { cvaIfFXOTimingEntry 1 }
cvaIfFXOTimingInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF inter-digit duration in milliseconds.
"
DEFVAL { 100 }
::= { cvaIfFXOTimingEntry 2 }
cvaIfFXOTimingPulseRate OBJECT-TYPE
SYNTAX Integer32 (10..20)
UNITS "pulses per second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing pulse dialing rate in pulses per second (pps).
"
DEFVAL { 10 }
::= { cvaIfFXOTimingEntry 3 }
cvaIfFXOTimingPulseInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (100..1000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing pulse dialing inter-digit timing in milliseconds.
"
DEFVAL { 500 }
::= { cvaIfFXOTimingEntry 4 }
--****************************************************************************
-- The Foreign Exchange Station (FXS) Standard Configuration Table
--****************************************************************************
-- This table is used to configure the FXS signaling type, Ring frequency
cvaIfFXSCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfFXSCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FXS standard configuration table. It contains
FXS configuration parameters, one entry per FXS interface.
The configuration information of this table is set by
hardware with its default setting or CLI during the hardware
installation time.
"
::= { cvaIfFXSObjects 1 }
cvaIfFXSCfgEntry OBJECT-TYPE
SYNTAX CvaIfFXSCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the standard configuration table for
each FXS interface."
INDEX { ifIndex }
::= { cvaIfFXSCfgTable 1 }
CvaIfFXSCfgEntry ::=
SEQUENCE {
cvaIfFXSCfgSignalType INTEGER,
cvaIfFXSRingFrequency INTEGER
}
cvaIfFXSCfgSignalType OBJECT-TYPE
SYNTAX INTEGER {
fxsLoopStart (1),
fxsGroundStart (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the signaling type of FXS interface.
fxsLoopStart - loop start.
fxsGroundStart - ground start.
"
DEFVAL { fxsLoopStart }
::= { cvaIfFXSCfgEntry 1 }
cvaIfFXSRingFrequency OBJECT-TYPE
SYNTAX INTEGER {
ringFrequency25 (1),
ringFrequency50 (2),
ringFrequency20 (3),
ringFrequency30 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the ring frequency to be used in the FXS interface.
ringFrequency25 - ring frequency 25 Hertz.
ringFrequency50 - ring frequency 50 Hertz.
ringFrequency20 - ring frequency 20 Hertz.
ringFrequency30 - ring frequency 30 Hertz.
"
::= { cvaIfFXSCfgEntry 2 }
--****************************************************************************
-- The Foreign Exchange Station (FXS) interface Status Table
--****************************************************************************
cvaIfFXSStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfFXSStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Foreign Exchange Station (FXS) interface Status Table.
It contains hook status, ring active and other states of
the interface.
"
::= { cvaIfFXSObjects 2 }
cvaIfFXSStatusEntry OBJECT-TYPE
SYNTAX CvaIfFXSStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the status table for each FXS interface.
"
AUGMENTS { cvaIfFXSCfgEntry }
::= { cvaIfFXSStatusTable 1 }
CvaIfFXSStatusEntry ::=
SEQUENCE {
cvaIfFXSHookStatus INTEGER,
cvaIfFXSRingActive TruthValue,
cvaIfFXSRingGround TruthValue,
cvaIfFXSTipGround TruthValue
}
cvaIfFXSHookStatus OBJECT-TYPE
SYNTAX INTEGER {
onHook (1),
offHook (2),
trunked (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the hook status of FXS interface.
onHook - the connected equipment(e.g., phone) is onHook.
offHook - the connected equipment is offHook.
trunked - the connected equipment is trunked.
"
::= { cvaIfFXSStatusEntry 1 }
cvaIfFXSRingActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the outgoing ring active indication. If
the object value is true, then the interface is currently
generating ring out to the Key Telephone System (KTS) or
Plain Old Telephone (POT); otherwise, it doesn't.
"
::= { cvaIfFXSStatusEntry 2 }
cvaIfFXSRingGround OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming ring ground indication.
It is only valid when the cvaIfFXSCfgSignalType is
fxsGroundStart. If the object is true, then the interface
is presenting a ring ground to the connected equipment;
otherwise, it doesn't.
"
::= { cvaIfFXSStatusEntry 3 }
cvaIfFXSTipGround OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming tip ground indication.
It is only valid when the cvaIfFXSCfgSignalType is
fxsGroundStart. If the object is true, then the interface
is detecting a tip ground at the interface; otherwise,
it doesn't.
"
::= { cvaIfFXSStatusEntry 4 }
--****************************************************************************
-- The FXS Timing Parameters Table
--****************************************************************************
-- This table contains the FXS interface timing parameters information.
cvaIfFXSTimingTable OBJECT-TYPE
SYNTAX SEQUENCE OF CvaIfFXSTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FXS interface Timing Parameters table. It
contains the configuration of the various FXS signaling
protocol timing parameters.
"
::= { cvaIfFXSObjects 3 }
cvaIfFXSTimingEntry OBJECT-TYPE
SYNTAX CvaIfFXSTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the FXS Timing Parameters Table for
each FXS interface."
AUGMENTS { cvaIfFXSCfgEntry }
::= { cvaIfFXSTimingTable 1 }
CvaIfFXSTimingEntry ::=
SEQUENCE {
cvaIfFXSTimingDigitDuration Integer32,
cvaIfFXSTimingInterDigitDuration Integer32
}
cvaIfFXSTimingDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF digit duration in milliseconds.
"
DEFVAL { 100 }
::= { cvaIfFXSTimingEntry 1 }
cvaIfFXSTimingInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF inter-digit duration in milliseconds.
"
DEFVAL { 100 }
::= { cvaIfFXSTimingEntry 2 }
--****************************************************************************
-- Conformance and compliance statements
--****************************************************************************
-- conformance information
cvaIfMIBConformance
OBJECT IDENTIFIER ::= { ciscoVoiceAnalogIfMIB 3 }
cvaIfMIBCompliances
OBJECT IDENTIFIER ::= { cvaIfMIBConformance 1 }
cvaIfMIBGroups
OBJECT IDENTIFIER ::= { cvaIfMIBConformance 2 }
-- compliance statements
cvaIfMIBCompliance MODULE-COMPLIANCE
STATUS deprecated -- superceded by cvaIfMIBCompliance2
DESCRIPTION
"The compliance statement for entities which implement
the Cisco Analog Voice interface MIB"
MODULE -- compliance to this module
MANDATORY-GROUPS {
cvaIfGeneralGroup
}
GROUP cvaIfEMGroup
DESCRIPTION
"The E&M group is mandatory for devices that have the
E&M interfaces."
GROUP cvaIfFXOGroup
DESCRIPTION
"The FXO group is mandatory for devices that have the
FXO interfaces."
GROUP cvaIfFXSGroup
DESCRIPTION
"The FXS group is mandatory for devices that have the
FXO interfaces."
OBJECT cvaIfCfgImpedance
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfCfgIntegratedDSP
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfStatusInfoType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfMaintenanceMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfStatusSignalErrors
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgOperation
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgDialType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingPulseRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingPulseInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingClearWaitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxWinkWaitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxWinkDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingDelayStart
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxDelayDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMinDelayPulseWidth
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgNumberRings
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgSupDisconnect
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgDialType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingPulseRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingPulseInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSRingFrequency
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { cvaIfMIBCompliances 1 }
cvaIfMIBCompliance2 MODULE-COMPLIANCE
STATUS deprecated -- superceded by cvaIfMIBCompliance3
DESCRIPTION
"The compliance statement for entities which implement
the Cisco Analog Voice interface MIB"
MODULE -- compliance to this module
MANDATORY-GROUPS {
cvaIfGeneralGroup
}
GROUP cvaIfEMGroupRev1
DESCRIPTION
"The E&M group is mandatory for devices that
have the E&M interfaces."
GROUP cvaIfFXOGroup2
DESCRIPTION
"The FXO group is mandatory for devices that
have the FXO interfaces."
GROUP cvaIfFXSGroup
DESCRIPTION
"The FXS group is mandatory for devices that
have the FXO interfaces."
OBJECT cvaIfCfgImpedance
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfCfgIntegratedDSP
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfStatusInfoType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfMaintenanceMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfStatusSignalErrors
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgOperation
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgDialType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgLmrMCap
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgLmrECap
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingPulseRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingPulseInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingClearWaitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxWinkWaitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxWinkDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingDelayStart
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxDelayDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMinDelayPulseWidth
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingVoiceHangover
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimeoutLmrTeardown
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgNumberRings
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgSupDisconnect2
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgDialType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingPulseRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingPulseInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSRingFrequency
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { cvaIfMIBCompliances 2 }
cvaIfMIBCompliance3 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the Cisco Analog Voice interface MIB"
MODULE -- compliance to this module
MANDATORY-GROUPS {
cvaIfGeneralGroup
}
GROUP cvaIfEMGroupRev2
DESCRIPTION
"The E&M group is mandatory for devices that
have the E&M interfaces."
GROUP cvaIfFXOGroup2
DESCRIPTION
"The FXO group is mandatory for devices that
have the FXO interfaces."
GROUP cvaIfFXSGroup
DESCRIPTION
"The FXS group is mandatory for devices that
have the FXO interfaces."
OBJECT cvaIfCfgImpedance
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfCfgIntegratedDSP
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfStatusInfoType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfMaintenanceMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfStatusSignalErrors
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgOperation
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgDialType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgLmrMCap
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgLmrECap
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMCfgAutoGainControl
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingPulseRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingPulseInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingClearWaitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxWinkWaitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxWinkDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingDelayStart
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMaxDelayDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingMinDelayPulseWidth
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingVoiceHangover
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimeoutLmrTeardown
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimeoutPttXmt
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimeoutPttRcv
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfEMTimingDelayVoice
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgNumberRings
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgSupDisconnect2
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOCfgDialType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingPulseRate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXOTimingPulseInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSCfgSignalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSRingFrequency
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSTimingDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cvaIfFXSTimingInterDigitDuration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { cvaIfMIBCompliances 3 }
-- units of conformance
cvaIfGeneralGroup OBJECT-GROUP
OBJECTS {
cvaIfCfgIntegratedDSP,
cvaIfCfgImpedance,
cvaIfStatusInfoType,
cvaIfMaintenanceMode,
cvaIfStatusSignalErrors
}
STATUS current
DESCRIPTION
"The collection of objects providing general information
about the Cisco Analog Voice interfaces."
::= { cvaIfMIBGroups 1 }
cvaIfEMGroup OBJECT-GROUP
OBJECTS {
cvaIfEMInSeizureActive,
cvaIfEMOutSeizureActive,
cvaIfEMCfgSignalType,
cvaIfEMCfgOperation,
cvaIfEMCfgType,
cvaIfEMCfgDialType,
cvaIfEMTimingDigitDuration,
cvaIfEMTimingInterDigitDuration,
cvaIfEMTimingPulseRate,
cvaIfEMTimingPulseInterDigitDuration,
cvaIfEMTimingClearWaitDuration,
cvaIfEMTimingMaxWinkWaitDuration,
cvaIfEMTimingMaxWinkDuration,
cvaIfEMTimingDelayStart,
cvaIfEMTimingMaxDelayDuration,
cvaIfEMTimingMinDelayPulseWidth
}
STATUS deprecated -- superceded by cvaIfEMGroupRev1
DESCRIPTION
"The collection of objects providing information
about the Cisco E&M trunk interface."
::= { cvaIfMIBGroups 2 }
cvaIfFXOGroup OBJECT-GROUP
OBJECTS {
cvaIfFXOHookStatus,
cvaIfFXORingDetect,
cvaIfFXORingGround,
cvaIfFXOTipGround,
cvaIfFXOCfgSignalType,
cvaIfFXOCfgNumberRings,
cvaIfFXOCfgSupDisconnect,
cvaIfFXOCfgDialType,
cvaIfFXOTimingDigitDuration,
cvaIfFXOTimingInterDigitDuration,
cvaIfFXOTimingPulseRate,
cvaIfFXOTimingPulseInterDigitDuration
}
STATUS deprecated -- superceded by cvaIfFXOGroup2
DESCRIPTION
"The collection of objects providing information
about the Cisco FXO interface."
::= { cvaIfMIBGroups 3 }
cvaIfFXSGroup OBJECT-GROUP
OBJECTS {
cvaIfFXSHookStatus,
cvaIfFXSRingActive,
cvaIfFXSRingGround,
cvaIfFXSTipGround,
cvaIfFXSCfgSignalType,
cvaIfFXSRingFrequency,
cvaIfFXSTimingDigitDuration,
cvaIfFXSTimingInterDigitDuration
}
STATUS current
DESCRIPTION
"The collection of objects providing information
about the Cisco FXS interface."
::= { cvaIfMIBGroups 4 }
cvaIfFXOGroup2 OBJECT-GROUP
OBJECTS {
cvaIfFXOHookStatus,
cvaIfFXORingDetect,
cvaIfFXORingGround,
cvaIfFXOTipGround,
cvaIfFXOCfgSignalType,
cvaIfFXOCfgNumberRings,
cvaIfFXOCfgSupDisconnect2,
cvaIfFXOCfgDialType,
cvaIfFXOTimingDigitDuration,
cvaIfFXOTimingInterDigitDuration,
cvaIfFXOTimingPulseRate,
cvaIfFXOTimingPulseInterDigitDuration
}
STATUS current
DESCRIPTION
"The collection of objects providing information
about the Cisco FXO interface."
::= { cvaIfMIBGroups 5 }
cvaIfEMGroupRev1 OBJECT-GROUP
OBJECTS {
cvaIfEMInSeizureActive,
cvaIfEMOutSeizureActive,
cvaIfEMCfgSignalType,
cvaIfEMCfgOperation,
cvaIfEMCfgType,
cvaIfEMCfgDialType,
cvaIfEMTimingDigitDuration,
cvaIfEMTimingInterDigitDuration,
cvaIfEMTimingPulseRate,
cvaIfEMTimingPulseInterDigitDuration,
cvaIfEMTimingClearWaitDuration,
cvaIfEMTimingMaxWinkWaitDuration,
cvaIfEMTimingMaxWinkDuration,
cvaIfEMTimingDelayStart,
cvaIfEMTimingMaxDelayDuration,
cvaIfEMTimingMinDelayPulseWidth,
cvaIfEMCfgLmrMCap,
cvaIfEMCfgLmrECap,
cvaIfEMTimingVoiceHangover,
cvaIfEMTimeoutLmrTeardown
}
STATUS deprecated -- superceded by cvaIfEMGroupRev2
DESCRIPTION
"The collection of objects providing information
about the Cisco E&M trunk interface."
::= { cvaIfMIBGroups 6 }
cvaIfEMGroupRev2 OBJECT-GROUP
OBJECTS {
cvaIfEMInSeizureActive,
cvaIfEMOutSeizureActive,
cvaIfEMCfgSignalType,
cvaIfEMCfgOperation,
cvaIfEMCfgType,
cvaIfEMCfgDialType,
cvaIfEMTimingDigitDuration,
cvaIfEMTimingInterDigitDuration,
cvaIfEMTimingPulseRate,
cvaIfEMTimingPulseInterDigitDuration,
cvaIfEMTimingClearWaitDuration,
cvaIfEMTimingMaxWinkWaitDuration,
cvaIfEMTimingMaxWinkDuration,
cvaIfEMTimingDelayStart,
cvaIfEMTimingMaxDelayDuration,
cvaIfEMTimingMinDelayPulseWidth,
cvaIfEMCfgLmrMCap,
cvaIfEMCfgLmrECap,
cvaIfEMTimingVoiceHangover,
cvaIfEMTimeoutLmrTeardown,
cvaIfEMCfgAutoGainControl,
cvaIfEMTimeoutPttXmt,
cvaIfEMTimeoutPttRcv,
cvaIfEMTimingDelayVoice
}
STATUS current
DESCRIPTION
"The collection of objects providing information
about the Cisco E&M trunk interface."
::= { cvaIfMIBGroups 7 }
END