-- CISCO-VOICE-ANALOG-IF-MIB.my: Voice Analog Interface MIB file
|
|
--
|
|
-- September 1996 Hongchi Shih
|
|
--
|
|
-- Copyright (c) 1996-1997, 2001-2004 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
CISCO-VOICE-ANALOG-IF-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32,
|
|
Counter32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
ifIndex
|
|
FROM IF-MIB
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoVoiceAnalogIfMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200510030000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W. Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-voice@cisco.com"
|
|
DESCRIPTION
|
|
"Analog Voice Interface MIB module.
|
|
This MIB manages the E&M, FXO, FXS
|
|
Interfaces in the router.
|
|
"
|
|
REVISION "200510030000Z"
|
|
DESCRIPTION
|
|
"Extend cvaIfEMCfgSignalType to include
|
|
fgd(5) and fgd-eana(6)
|
|
"
|
|
REVISION "200410140000Z"
|
|
DESCRIPTION
|
|
"Extend CvaIfEMCfgEntry to include
|
|
cvaIfEMCfgAutoGainControl
|
|
Extend CvaIfEMTimingEntry to include
|
|
cvaIfEMTimeoutPttXmt
|
|
cvaIfEMTimeoutPttRcv
|
|
cvaIfEMTimingDelayVoice
|
|
add cvaIfEMGroupRev2
|
|
"
|
|
|
|
REVISION "200401150000Z"
|
|
DESCRIPTION
|
|
"Extend cvaIfEMCfgSignalType to include
|
|
lmr(4)
|
|
Extend CvaIfEMCfgEntry to include
|
|
cvaIfEMCfgLmrMCap & cvaIfEMCfgLmrECap
|
|
Extend CvaIfEMTimingEntry to include
|
|
cvaIfEMTimingVoiceHangover &
|
|
cvaIfEMTimeoutLmrTeardown
|
|
Deprecated cvaIfEMGroup
|
|
add cvaIfEMGroupRev1
|
|
Addition of fxoCama in cvaIfFXOCfgSignalType.
|
|
Deprecated cvaIfFXOCfgSupDisconnect in favor of
|
|
cvaIfFXOCfgSupDisconnect2.
|
|
Add cvaIfMIBCompliance2
|
|
"
|
|
REVISION "200208030000Z"
|
|
DESCRIPTION
|
|
"Addition of fxoCama in cvaIfFXOCfgSignalType.
|
|
"
|
|
|
|
REVISION "200207290000Z"
|
|
DESCRIPTION
|
|
"Deprecated cvaIfFXOCfgSupDisconnect in favor of
|
|
cvaIfFXOCfgSupDisconnect2.
|
|
"
|
|
|
|
REVISION "200201210000Z"
|
|
DESCRIPTION
|
|
"Created TC InterfaceDialType. Updated
|
|
cvaIfEMCfgDialType and cvaIfFXOCfgDialType
|
|
objects to use this TC InterfaceDialType.
|
|
Added enumeration 'trunked(3)' to the SYNTAX of
|
|
cvaIfFXSHookStatus.
|
|
Added enumeration 'trunked(3)' to the SYNTAX of
|
|
cvaIfFXOHookStatus.
|
|
"
|
|
::= { ciscoMgmt 62 }
|
|
|
|
--
|
|
-- Overview of Analog Voice interface MIB
|
|
--
|
|
-- The Analog Voice interface MIB provides the standard configuration,
|
|
-- timing parameters and telephony hook, ring status information on Cisco's
|
|
-- Analog Voice interface implementation. The following groups
|
|
-- are managed:
|
|
-- 1) Analog interface general group
|
|
-- 2) E&M (recEive and transMit) interface group
|
|
-- 3) FXO (Foreign Exchange Office) interface group
|
|
-- 4) FXS (Foreign Exchange Station) interface group
|
|
--
|
|
-- ifEntry for an Analog Voice Interface
|
|
--
|
|
-- The ifEntry for an Analog Voice Interface supports the
|
|
-- ifGeneralInformationGroup of Cisco IF-MIB.
|
|
|
|
-- ifTable Comments
|
|
-- ============== =====================================================
|
|
-- ifIndex Each Analog telephony interface is represented by an
|
|
-- ifEntry.
|
|
-- ifDescr Textual port description.
|
|
-- ifType The IANA value of voiceEM(100), voiceFXO(101) and
|
|
-- voiceFXS(102).
|
|
-- ifSpeed contains a zero value.
|
|
-- ifPhysAddress contains an octet string of zero length.
|
|
--
|
|
-- ifAdminStatus The desired administrative status of the
|
|
-- Analog Telephony interface port.
|
|
-- ifOperStatus The current operational status of the Analog Telephony
|
|
-- interface port. Note that dormant(5) is explicitly being
|
|
-- used as defined in RFC 1573.
|
|
-- ifLastChange Refer to RFC 1573.
|
|
-- ifLinkUpDownTrapEnable
|
|
-- Refer to RFC 1573.
|
|
-- ifConnectorPresent
|
|
-- Refer to RFC 1573.
|
|
-- ifHighSpeed contains a zero value.
|
|
-- ifName Refer to RFC 1573.
|
|
-- ifAlias Refer to Cisco IF-MIB.
|
|
--
|
|
|
|
--
|
|
-- Relationship to the IETF Dial Control MIB (RFC2128)
|
|
--
|
|
-- Associating and disassociating an analog voice interface with
|
|
-- a connection can be explicitly handled using an ifStack. If a
|
|
-- call connection is established, the managed system correlates the call
|
|
-- associated voice encapsulation interface with the analog voice interface
|
|
-- via ifStack based on the section 2.2.1 of RFC2128.
|
|
|
|
|
|
|
|
cvaIfObjects OBJECT IDENTIFIER ::= { ciscoVoiceAnalogIfMIB 1 }
|
|
cvaIfGeneralObjects OBJECT IDENTIFIER ::= { cvaIfObjects 1 }
|
|
cvaIfEMObjects OBJECT IDENTIFIER ::= { cvaIfObjects 2 }
|
|
cvaIfFXOObjects OBJECT IDENTIFIER ::= { cvaIfObjects 3 }
|
|
cvaIfFXSObjects OBJECT IDENTIFIER ::= { cvaIfObjects 4 }
|
|
|
|
--
|
|
-- Textual Conventions
|
|
--
|
|
|
|
|
|
--
|
|
-- Dial Type Textual Conventions
|
|
--
|
|
|
|
InterfaceDialType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the out dialing type of E&M interface and
|
|
FXO type interfaces.
|
|
dtmf - DTMF digit.
|
|
pulse - pulse.
|
|
mf - mf digit.
|
|
"
|
|
SYNTAX INTEGER {
|
|
dtmf (1),
|
|
pulse (2),
|
|
mf (3)
|
|
}
|
|
|
|
--****************************************************************************
|
|
-- The Analog Voice General Interface Group
|
|
--****************************************************************************
|
|
-- [1] Analog Voice Interface Standard Configuration Table
|
|
-- [2] Analog Voice Interface Status Table
|
|
|
|
|
|
|
|
--****************************************************************************
|
|
-- The Analog Voice Interface Standard Configuration Table
|
|
--****************************************************************************
|
|
cvaIfCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Analog Voice Standard Configuration Table. It contains
|
|
the standard configuration information of the analog
|
|
telephony interface.
|
|
"
|
|
::= { cvaIfGeneralObjects 1 }
|
|
|
|
cvaIfCfgEntry OBJECT-TYPE
|
|
SYNTAX CvaIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the configuration table for each voice analog
|
|
interface. The entry is created when the voice analog
|
|
hardware is detected.
|
|
"
|
|
INDEX { ifIndex }
|
|
::= { cvaIfCfgTable 1 }
|
|
|
|
CvaIfCfgEntry ::=
|
|
SEQUENCE {
|
|
cvaIfCfgImpedance INTEGER,
|
|
cvaIfCfgIntegratedDSP TruthValue
|
|
}
|
|
|
|
|
|
cvaIfCfgImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
ohms600Real (2),
|
|
ohms600Complex (3),
|
|
ohms900Complex (4),
|
|
ohmsComplex1 (5),
|
|
ohmsComplex2 (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the terminating impedance of voice analog
|
|
interfaces.
|
|
other - none of the following; arbitrary,
|
|
within limits, for special cases.
|
|
ohms600Real - 600 Ohms.
|
|
ohms600Complex - 600 Ohms + 2.16uF
|
|
ohms900Complex - 900 Ohms + 2.16uF.
|
|
ohmsComplex1 - complex 1;
|
|
220 Ohms + 820 Ohms || 115nF.
|
|
This impedance is primarily used in
|
|
Germany.
|
|
ohmsComplex2 - complex 2;
|
|
270 Ohms + 750 Ohms || 150nF.
|
|
This impedance is primarily used in
|
|
United Kingdom and Sweden.
|
|
"
|
|
::= { cvaIfCfgEntry 1 }
|
|
|
|
cvaIfCfgIntegratedDSP OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the interface has an integrated
|
|
Digital Signal processing (DSP) unit.
|
|
"
|
|
::= { cvaIfCfgEntry 2 }
|
|
|
|
--****************************************************************************
|
|
-- The Analog Voice Interface Status Table
|
|
--****************************************************************************
|
|
cvaIfStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Analog Voice Status Table. It contains general
|
|
information about the status of Analog Telephony interface
|
|
including the error statistics.
|
|
"
|
|
::= { cvaIfGeneralObjects 2 }
|
|
|
|
cvaIfStatusEntry OBJECT-TYPE
|
|
SYNTAX CvaIfStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the status table for each Analog voice interface.
|
|
"
|
|
AUGMENTS { cvaIfCfgEntry }
|
|
::= { cvaIfStatusTable 1 }
|
|
|
|
CvaIfStatusEntry ::=
|
|
SEQUENCE {
|
|
cvaIfStatusInfoType INTEGER,
|
|
cvaIfMaintenanceMode INTEGER,
|
|
cvaIfStatusSignalErrors Counter32
|
|
}
|
|
|
|
|
|
cvaIfStatusInfoType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
voice(2),
|
|
g3Fax(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The information transfer services for the current
|
|
or last call.
|
|
none - no information transfer service
|
|
voice - analog voice.
|
|
g3Fax - Group 3 FAX.
|
|
"
|
|
::= { cvaIfStatusEntry 1 }
|
|
|
|
cvaIfMaintenanceMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
hostCompressedLoopback (2),
|
|
hostUncompressedLoopback (3),
|
|
ifCompressedLoopback (4),
|
|
ifUncompressedLoopback (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maintenance modes of the Analog voice interface.
|
|
|
|
Managed system
|
|
+=============+=============================+
|
|
| Voice | +===========+ telephony |
|
|
<=====+ application +===+ CODEC +===end point +=== test
|
|
IP | (Host) | . +===========+ .(Interface)| equipment
|
|
backbone +=============+=============================+
|
|
. .
|
|
Host ======>===+ .
|
|
Compressed <======+ .
|
|
. .
|
|
Host ===================>======+
|
|
Uncompressed <======================+
|
|
. .
|
|
Interface +========<==========================
|
|
Compressed +==================================>
|
|
. .
|
|
Interface . +===<===============
|
|
Uncompressed . +==================>
|
|
Compress Uncompress
|
|
Loopback Loopback
|
|
point point
|
|
|
|
none(1) - the interface is not in maintenance mode.
|
|
hostCompressedLoopback(2) - Host Compressed Loopback.
|
|
This mode is set by the managed system to perform the
|
|
compressed voice loopback test. The voice packet is passed
|
|
by voice application to the interface associated CODEC.
|
|
Instead of feeding these into the CODEC for decompression,
|
|
they are immediately sent back to the voice application as
|
|
if they had originated locally and been compressed.
|
|
|
|
hostUncompressedLoopback(3) - Host Uncompressed Loopback.
|
|
This mode is set by the managed system to perform the
|
|
uncompressed voice loopback test. The voice packet is
|
|
sent by voice application all the way through the
|
|
interface associated CODEC and then turned around instead
|
|
of being sent to the telephony endpoint.
|
|
|
|
ifCompressedLoopback(4) - Interface Compressed Loopback.
|
|
This mode is set by the managed system to perform the
|
|
interface uncompressed voice loopback test for the
|
|
external test equipment that is connected to the voice
|
|
interface.
|
|
The voice samples are sent from the test equipment all the
|
|
way through the interface associated CODEC and then turned
|
|
around instead of being sent to voice application.
|
|
|
|
ifUncompressedLoopback(5) - Interface Uncompressed Loopback.
|
|
This mode is set by the managed system to perform the
|
|
interface uncompressed voice loopback test for the
|
|
external test equipment that is connected to the voice
|
|
interface.
|
|
The voice samples are sent from the test equipment to the
|
|
interface associated CODEC. Instead of feeding the voice
|
|
samples into the CODEC for compression, they are
|
|
immediately sent back to the telephony interface.
|
|
"
|
|
::= { cvaIfStatusEntry 2 }
|
|
|
|
cvaIfStatusSignalErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Accumulated number of signaling protocol errors that are
|
|
detected in the interface since system startup."
|
|
::= { cvaIfStatusEntry 3 }
|
|
|
|
|
|
--****************************************************************************
|
|
-- The E&M Standard Configuration Table
|
|
--****************************************************************************
|
|
|
|
-- This table is used to configure the E&M type, signaling, operation,
|
|
-- dial type for the E&M interface.
|
|
|
|
cvaIfEMCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfEMCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The E&M standard configuration table. It contains
|
|
the current setting of E&M configurable parameters.
|
|
"
|
|
::= { cvaIfEMObjects 1 }
|
|
|
|
cvaIfEMCfgEntry OBJECT-TYPE
|
|
SYNTAX CvaIfEMCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the standard configuration table for
|
|
each E&M tie trunk interface."
|
|
INDEX { ifIndex }
|
|
::= { cvaIfEMCfgTable 1 }
|
|
|
|
CvaIfEMCfgEntry ::=
|
|
SEQUENCE {
|
|
cvaIfEMCfgSignalType INTEGER,
|
|
cvaIfEMCfgOperation INTEGER,
|
|
cvaIfEMCfgType INTEGER,
|
|
cvaIfEMCfgDialType InterfaceDialType,
|
|
cvaIfEMCfgLmrMCap INTEGER,
|
|
cvaIfEMCfgLmrECap INTEGER,
|
|
cvaIfEMCfgAutoGainControl TruthValue
|
|
}
|
|
|
|
cvaIfEMCfgSignalType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
winkStart (1),
|
|
immediateDial (2),
|
|
delayDial (3),
|
|
lmr (4),
|
|
fgd (5),
|
|
fgd-eana (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signaling type of E&M tie trunk interface.
|
|
winkStart - the calling side seizes the line by going
|
|
off-hook on its E lead but waits for a short
|
|
off-hook 'wink' indication on its M lead from
|
|
the called side before sending address
|
|
information as DTMF digits.
|
|
immediateDial - the calling side seizes the line by going
|
|
off-hook on its E lead and sends sends address
|
|
information as DTMF digits.
|
|
delayDial - the calling side seizes the line by going
|
|
off-hook on its E lead. After a timing interval,
|
|
the calling side looks at the supervision
|
|
from the called side. If the supervision is
|
|
on-hook, the calling side starts sending
|
|
information as DTMF digits; otherwise, the calling
|
|
side waits until the called side goes
|
|
on-hook and then starts sending address
|
|
information.
|
|
lmr - the e&m port is used to interface with
|
|
Land Mobil Radio system. The e-lead and
|
|
m-lead are not used in the traditional
|
|
way.
|
|
fgd - Feature Group D is an access switched services
|
|
that provides access to Local Exchange Carrier
|
|
of the public switched network. It is supported
|
|
in North America only based on E&M wink-start.
|
|
fgd-eana - Exchange Access North American signalling
|
|
protocol of Feature Group D.
|
|
"
|
|
REFERENCE
|
|
"EIA/TIA-464B: Sections 4.1.3.4.1 Signaling Protocols.
|
|
"
|
|
DEFVAL { winkStart }
|
|
::= { cvaIfEMCfgEntry 1 }
|
|
|
|
cvaIfEMCfgOperation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
twoWires (1),
|
|
fourWires (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the operation of the E&M signal.
|
|
twoWires - 2-wire operation.
|
|
fourWires - 4-wire operation.
|
|
"
|
|
DEFVAL { twoWires }
|
|
::= { cvaIfEMCfgEntry 2 }
|
|
|
|
|
|
cvaIfEMCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
typeI (1),
|
|
typeII (2),
|
|
typeIII (3),
|
|
typeIV (4),
|
|
typeV (5)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the E&M Lead Signaling type.
|
|
LEGEND: V = -48V
|
|
/\/\/ = detector/resister
|
|
X = normally open relay contact
|
|
+ = normally closed relay contact
|
|
G = ground
|
|
SB = Signal Battery
|
|
SG = Signal Ground
|
|
|
|
typeI -
|
|
Leads: E (output, relay to ground)
|
|
M (input, referenced to ground)
|
|
|
|
The tie line equipment (switch/router/etc) generates the
|
|
E-signal to the PBX type grounding the E-lead.
|
|
The tie line equipment detects the M-signal by detecting
|
|
current flow to ground. A common ground must exist
|
|
between the line equipment and the PBX.
|
|
|
|
PBX | TIE LINE
|
|
|
|
|
E: V--/\/\/---|-----X----G
|
|
|
|
|
M: V----X-----|---/\/\/--G
|
|
|
|
typeII -
|
|
Leads: E (output, relay to SG)
|
|
M (input, referenced to ground)
|
|
SB (feed for M, connected to -48V)
|
|
SG (return for E, galvanically isolated from ground)
|
|
|
|
This interface requires no common ground between the
|
|
equipment, thus avoiding ground loop noise problems.
|
|
E-signal is generated toward the PBX by connecting it
|
|
to SG. M-signal is indicated by the PBX connecting
|
|
it to SB. While this interface does NOT require a
|
|
common ground, it does have the tendency to inject
|
|
noise into the audio paths since it is asymmetrical
|
|
with respect to current flow between devices.
|
|
|
|
PBX | TIE LINE
|
|
|
|
|
E: V--/\/\/---|-----X----
|
|
| |
|
|
SG: G----------|----------
|
|
|
|
|
M: ----X-----|---/\/\/--G
|
|
| |
|
|
SB: ----------|----------V
|
|
|
|
typeIII -
|
|
Leads: E (output, relay to ground)
|
|
M (input, referenced to ground)
|
|
SB (connected to -48V)
|
|
SG (connected to ground)
|
|
|
|
This interface operates similar to type I with respect
|
|
to the E-signal. The M-signal, however, is indicated by
|
|
the PBX connecting it to SB on assertion, and alternately
|
|
connecting it to SG during inactivity. Unfortunately, a
|
|
common ground must be shared between the equipment.
|
|
|
|
PBX | TIE LINE
|
|
|
|
|
E: V--/\/\/---|-----X----G
|
|
|
|
|
SG: ----------|----------G
|
|
+ |
|
|
M: ----------|---/\/\/--G
|
|
X |
|
|
SB: ----------|----------V
|
|
|
|
typeIV -
|
|
Leads: E (output, relay to SG)
|
|
M (input, referenced to -48V)
|
|
SB (feed for M, connected to ground)
|
|
SG (return for E, galvanically isolated from ground)
|
|
|
|
This interface is fully symmetrical; it does not require
|
|
a common ground, does not inject noise into audio paths,
|
|
and can be connected back to back by swapping E/SG for
|
|
M/SB. E-signal is indicated to the PBX by connecting it
|
|
to SG. M-signal is provided by the PBX connecting it to
|
|
SB.
|
|
|
|
PBX | TIE LINE
|
|
|
|
|
E: V--/\/\/---|-----X----
|
|
| |
|
|
SG: G----------|----------
|
|
|
|
|
M: ----------|---/\/\/--V
|
|
X |
|
|
SB: ----------|----------G
|
|
|
|
typeV -
|
|
Leads: E (output, relay to ground)
|
|
M (input, referenced to -48V)
|
|
|
|
Type V line equipment indicates E-signal to the PBX by
|
|
grounding the E-lead. The PBX indicates M-signal by
|
|
grounding the M-lead. This interface does require a
|
|
common ground, but does allow back to back connections
|
|
by swapping E for M. This interface is quasi-symmetric
|
|
in that while the line is up, current flow is more or
|
|
less equal between the PBX and line equipment. But noise
|
|
injection is still a problem.
|
|
|
|
PBX | TIE LINE
|
|
|
|
|
E: V--/\/\/---|-----X----G
|
|
|
|
|
M: G-----X----|---/\/\/--V
|
|
|
|
|
"
|
|
REFERENCE
|
|
"EIA/TIA-464B: Sections 4.2.3 E&M Lead Signaling.
|
|
"
|
|
DEFVAL { typeI }
|
|
::= { cvaIfEMCfgEntry 3 }
|
|
|
|
cvaIfEMCfgDialType OBJECT-TYPE
|
|
SYNTAX InterfaceDialType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the out dialing type of E&M interface.
|
|
"
|
|
DEFVAL { dtmf }
|
|
::= { cvaIfEMCfgEntry 4 }
|
|
|
|
cvaIfEMCfgLmrMCap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inact (1),
|
|
audio (2),
|
|
dial (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The M lead behavior of E&M LMR interface.
|
|
inact - The m-lead status should be ignored.
|
|
audio - The m-lead status is used to control
|
|
generating voice packet.
|
|
dial - Perform the same audio case except abling to
|
|
initiate a call when offhook in a idle state.
|
|
"
|
|
DEFVAL { inact }
|
|
::= { cvaIfEMCfgEntry 5 }
|
|
|
|
cvaIfEMCfgLmrECap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
seize (4),
|
|
voice (5),
|
|
inactive (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The E lead behavior of E&M LMR interface.
|
|
seize - The e-lead used as seize signal
|
|
voice - The e-lead status is used to indicate
|
|
voice packet received or not.
|
|
inactive -- e-lead is inactive.
|
|
"
|
|
DEFVAL { seize }
|
|
::= { cvaIfEMCfgEntry 6 }
|
|
|
|
cvaIfEMCfgAutoGainControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to enabling/disabling automatic
|
|
gain control(AGC) on this interface. AGC allows DSP
|
|
to adjust the input voice volume and avoid rapid
|
|
voice volume change.
|
|
"
|
|
DEFVAL { false }
|
|
::= { cvaIfEMCfgEntry 7 }
|
|
|
|
--****************************************************************************
|
|
-- The E&M interface Status Table
|
|
--****************************************************************************
|
|
|
|
cvaIfEMStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfEMStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The E&M interface Table. The table contains
|
|
the status of the E&M tie trunk interface.
|
|
"
|
|
::= { cvaIfEMObjects 2 }
|
|
|
|
cvaIfEMStatusEntry OBJECT-TYPE
|
|
SYNTAX CvaIfEMStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the status table for each E&M interface.
|
|
"
|
|
AUGMENTS { cvaIfEMCfgEntry }
|
|
::= { cvaIfEMStatusTable 1 }
|
|
|
|
CvaIfEMStatusEntry ::=
|
|
SEQUENCE {
|
|
cvaIfEMInSeizureActive TruthValue,
|
|
cvaIfEMOutSeizureActive TruthValue
|
|
}
|
|
|
|
cvaIfEMInSeizureActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the incoming seizure state of the E&M
|
|
interface. If the value is true, then the interface has an
|
|
incoming trunk seizure active; otherwise, it doesn't.
|
|
"
|
|
::= { cvaIfEMStatusEntry 1 }
|
|
|
|
cvaIfEMOutSeizureActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the outgoing seizure state of the E&M
|
|
interface. If the value is true, then the interface has an
|
|
outgoing trunk seizure active; otherwise, it doesn't.
|
|
"
|
|
::= { cvaIfEMStatusEntry 2 }
|
|
|
|
|
|
|
|
|
|
--****************************************************************************
|
|
-- The E&M Timing Parameters Table
|
|
--****************************************************************************
|
|
|
|
-- This table contains the E&M interface timing parameters information.
|
|
|
|
cvaIfEMTimingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfEMTimingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The E&M tie trunk Timing Parameters table. It
|
|
contains the configuration of the various E&M signaling
|
|
protocol timing parameters.
|
|
"
|
|
::= { cvaIfEMObjects 3 }
|
|
|
|
cvaIfEMTimingEntry OBJECT-TYPE
|
|
SYNTAX CvaIfEMTimingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the E&M Timing Parameters Table for
|
|
each E&M interface."
|
|
AUGMENTS { cvaIfEMCfgEntry }
|
|
::= { cvaIfEMTimingTable 1 }
|
|
|
|
CvaIfEMTimingEntry ::=
|
|
SEQUENCE {
|
|
cvaIfEMTimingDigitDuration Integer32,
|
|
cvaIfEMTimingInterDigitDuration Integer32,
|
|
cvaIfEMTimingPulseRate Integer32,
|
|
cvaIfEMTimingPulseInterDigitDuration Integer32,
|
|
cvaIfEMTimingClearWaitDuration Integer32,
|
|
cvaIfEMTimingMaxWinkWaitDuration Integer32,
|
|
cvaIfEMTimingMaxWinkDuration Integer32,
|
|
cvaIfEMTimingDelayStart Integer32,
|
|
cvaIfEMTimingMaxDelayDuration Integer32,
|
|
cvaIfEMTimingMinDelayPulseWidth Integer32,
|
|
cvaIfEMTimingVoiceHangover Integer32,
|
|
cvaIfEMTimeoutLmrTeardown Integer32,
|
|
cvaIfEMTimeoutPttXmt Integer32,
|
|
cvaIfEMTimeoutPttRcv Integer32,
|
|
cvaIfEMTimingDelayVoice Integer32
|
|
}
|
|
|
|
cvaIfEMTimingDigitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (50..500)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing DTMF digit duration in milliseconds.
|
|
"
|
|
DEFVAL { 100 }
|
|
::= { cvaIfEMTimingEntry 1 }
|
|
|
|
cvaIfEMTimingInterDigitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (50..500)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing DTMF inter-digit duration in milliseconds.
|
|
"
|
|
DEFVAL { 100 }
|
|
::= { cvaIfEMTimingEntry 2 }
|
|
|
|
cvaIfEMTimingPulseRate OBJECT-TYPE
|
|
SYNTAX Integer32 (10..20)
|
|
UNITS "pulses per second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing pulse dialing rate in pulses per second (pps).
|
|
"
|
|
DEFVAL { 10 }
|
|
::= { cvaIfEMTimingEntry 3 }
|
|
|
|
cvaIfEMTimingPulseInterDigitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (100..1000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing Pulse dialing inter-digit timing in
|
|
milliseconds.
|
|
"
|
|
DEFVAL { 750 }
|
|
::= { cvaIfEMTimingEntry 4 }
|
|
|
|
cvaIfEMTimingClearWaitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (200..2000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time of Inactive seizure signal to declare call cleared.
|
|
"
|
|
DEFVAL { 400 }
|
|
::= { cvaIfEMTimingEntry 5 }
|
|
|
|
cvaIfEMTimingMaxWinkWaitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (100..5000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum time to wait from the outgoing seizure of the line
|
|
to the time of sending out a wink-pulse.
|
|
"
|
|
DEFVAL { 200 }
|
|
::= { cvaIfEMTimingEntry 6 }
|
|
|
|
cvaIfEMTimingMaxWinkDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (100..3000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum outgoing wink duration (between the wink-pulse leading
|
|
edge and trailing edge) for wink start signaling.
|
|
"
|
|
DEFVAL { 200 }
|
|
::= { cvaIfEMTimingEntry 7 }
|
|
|
|
cvaIfEMTimingDelayStart OBJECT-TYPE
|
|
SYNTAX Integer32 (20..2000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum time to wait from outgoing seizure to
|
|
out-dialing digits for delay start signaling.
|
|
"
|
|
DEFVAL { 300 }
|
|
::= { cvaIfEMTimingEntry 8 }
|
|
|
|
cvaIfEMTimingMaxDelayDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (100..5000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum time to wait from outgoing seizure to
|
|
out-dialing digits. If the far end does not allow to
|
|
send digits after the duration specified in the object,
|
|
a reorder tone will be sent to the calling party.
|
|
"
|
|
DEFVAL { 2000 }
|
|
::= { cvaIfEMTimingEntry 9 }
|
|
|
|
cvaIfEMTimingMinDelayPulseWidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0 | 140..5000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum delay-dial pulse duration for incoming call.
|
|
If the value of this object is 0, then no delay-dial
|
|
is sent to the far end for the incoming call.
|
|
"
|
|
DEFVAL { 140 }
|
|
::= { cvaIfEMTimingEntry 10 }
|
|
|
|
cvaIfEMTimingVoiceHangover OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hangover time used to determine the casethere is
|
|
no more voice packet arrived.
|
|
"
|
|
DEFVAL { 250 }
|
|
::= { cvaIfEMTimingEntry 11 }
|
|
|
|
cvaIfEMTimeoutLmrTeardown OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 5..60000)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LMR port tear down timeout.
|
|
This object is relevant to the waiting time of
|
|
teardown call on LMR port.
|
|
if the value of this object is '-1', then the timeout
|
|
is disable.
|
|
"
|
|
DEFVAL { 1800 }
|
|
::= { cvaIfEMTimingEntry 12 }
|
|
|
|
cvaIfEMTimeoutPttXmt OBJECT-TYPE
|
|
SYNTAX Integer32 (0..30)
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object signifies LMR port maxinum transmit time.
|
|
This object is relevant to how long LMR port can
|
|
continue transmit voice packet without pause.
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { cvaIfEMTimingEntry 13 }
|
|
|
|
cvaIfEMTimeoutPttRcv OBJECT-TYPE
|
|
SYNTAX Integer32 (0..30)
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object signifies LMR port maxinum receive time.
|
|
This object is relevant to how long LMR port can
|
|
continue receive voice packet without pause.
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { cvaIfEMTimingEntry 14 }
|
|
|
|
cvaIfEMTimingDelayVoice OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1500)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is relevant to how long DSP will delay
|
|
sending the voice packet to the LMR port.
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { cvaIfEMTimingEntry 15 }
|
|
|
|
--****************************************************************************
|
|
-- The Foreign Exchange Office (FXO) Standard Configuration Table
|
|
--****************************************************************************
|
|
|
|
-- This table is used to configure the FXO signaling and number of rings
|
|
-- for the FXO interface.
|
|
|
|
cvaIfFXOCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfFXOCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The FXO standard configuration table. It contains
|
|
FXO configuration parameters, one entry per FXO interface.
|
|
The configuration information of this table is set by
|
|
hardware with its default setting or CLI during the hardware
|
|
installation time.
|
|
"
|
|
::= { cvaIfFXOObjects 1 }
|
|
|
|
cvaIfFXOCfgEntry OBJECT-TYPE
|
|
SYNTAX CvaIfFXOCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the standard configuration table for
|
|
each FXO interface."
|
|
INDEX { ifIndex }
|
|
::= { cvaIfFXOCfgTable 1 }
|
|
|
|
CvaIfFXOCfgEntry ::=
|
|
SEQUENCE {
|
|
cvaIfFXOCfgSignalType INTEGER,
|
|
cvaIfFXOCfgNumberRings Integer32,
|
|
cvaIfFXOCfgSupDisconnect TruthValue,
|
|
cvaIfFXOCfgDialType InterfaceDialType,
|
|
cvaIfFXOCfgSupDisconnect2 INTEGER
|
|
}
|
|
|
|
cvaIfFXOCfgSignalType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fxoLoopStart (1),
|
|
fxoGroundStart (2),
|
|
fxoCama (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the signaling type of FXO interface.
|
|
fxoLoopStart - loop start.
|
|
fxoGroundStart - ground start.
|
|
fxoCama - cama.
|
|
"
|
|
DEFVAL { fxoLoopStart }
|
|
::= { cvaIfFXOCfgEntry 1 }
|
|
|
|
cvaIfFXOCfgNumberRings OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
UNITS "rings"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of rings detected before closing loop.
|
|
"
|
|
DEFVAL { 1 }
|
|
::= { cvaIfFXOCfgEntry 2 }
|
|
|
|
cvaIfFXOCfgSupDisconnect OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated -- superceded by cvaIfFXOCfgSupDisconnect2
|
|
DESCRIPTION
|
|
" Specifies whether a supervisory disconnect signal (CPC) will
|
|
be presented to the interface when the connected party at
|
|
the interface hangs up.
|
|
"
|
|
DEFVAL { true }
|
|
::= { cvaIfFXOCfgEntry 3 }
|
|
|
|
cvaIfFXOCfgDialType OBJECT-TYPE
|
|
SYNTAX InterfaceDialType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the out dialing type of FXO interface.
|
|
"
|
|
DEFVAL { dtmf }
|
|
::= { cvaIfFXOCfgEntry 4 }
|
|
|
|
cvaIfFXOCfgSupDisconnect2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
signal(0),
|
|
anytone(1),
|
|
dualtoneMidcall(2),
|
|
dualtonePreconnect(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Specifies the type of supervisory disconnect signal
|
|
(CPC) to be presented to the interface when the
|
|
connected party at the interface hangs up.
|
|
signal - power denial recognition
|
|
anytone - tone detection of all call progressing tones
|
|
dualtoneMidcall - tone detection to operate throughout
|
|
the call duration
|
|
dualtonePreconnect - tone detection to operate only
|
|
during call setup
|
|
"
|
|
DEFVAL { signal }
|
|
::= { cvaIfFXOCfgEntry 5 }
|
|
|
|
--****************************************************************************
|
|
-- The Foreign Exchange Office (FXO) interface Status Table
|
|
--****************************************************************************
|
|
|
|
cvaIfFXOStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfFXOStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Foreign Exchange Office (FXO) interface Status Table.
|
|
It contains hook status, ring detection and other states of
|
|
the interface.
|
|
"
|
|
::= { cvaIfFXOObjects 2 }
|
|
|
|
cvaIfFXOStatusEntry OBJECT-TYPE
|
|
SYNTAX CvaIfFXOStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the status table for each FXO interface.
|
|
"
|
|
AUGMENTS { cvaIfFXOCfgEntry }
|
|
::= { cvaIfFXOStatusTable 1 }
|
|
|
|
CvaIfFXOStatusEntry ::=
|
|
SEQUENCE {
|
|
cvaIfFXOHookStatus INTEGER,
|
|
cvaIfFXORingDetect TruthValue,
|
|
cvaIfFXORingGround TruthValue,
|
|
cvaIfFXOTipGround TruthValue
|
|
}
|
|
|
|
cvaIfFXOHookStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
onHook (1),
|
|
offHook (2),
|
|
trunked (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the hook status of FXO interface.
|
|
onHook - Present the onHook to the connected equipment.
|
|
offHook - Present the offHook to the connected equipment.
|
|
trunked - Present the trunk to the connected equipment.
|
|
"
|
|
::= { cvaIfFXOStatusEntry 1 }
|
|
|
|
|
|
cvaIfFXORingDetect OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the ring detect indication. If the
|
|
value is true, then the interface detects ring from PBX or
|
|
CO; otherwise, it doesn't."
|
|
::= { cvaIfFXOStatusEntry 2 }
|
|
|
|
|
|
cvaIfFXORingGround OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the incoming ring ground indication.
|
|
It is only valid when the cvaIfFXOCfgSignalType is
|
|
fxoGroundStart. If the object is true, then the interface
|
|
is presenting a ring ground to the connected equipment;
|
|
otherwise, it doesn't.
|
|
"
|
|
::= { cvaIfFXOStatusEntry 3 }
|
|
|
|
cvaIfFXOTipGround OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the incoming tip ground indication.
|
|
It is only valid when the cvaIfFXOCfgSignalType is
|
|
fxoGroundStart. If the object is true, then the interface
|
|
is detecting a tip ground at the interface; otherwise,
|
|
it doesn't.
|
|
"
|
|
::= { cvaIfFXOStatusEntry 4 }
|
|
|
|
|
|
--****************************************************************************
|
|
-- The FXO Timing Parameters Table
|
|
--****************************************************************************
|
|
-- This table contains the FXO interface timing parameters information.
|
|
|
|
cvaIfFXOTimingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfFXOTimingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The FXO interface Timing Parameters table. It
|
|
contains the configuration of the various FXO signaling
|
|
protocol timing parameters.
|
|
"
|
|
::= { cvaIfFXOObjects 3 }
|
|
|
|
cvaIfFXOTimingEntry OBJECT-TYPE
|
|
SYNTAX CvaIfFXOTimingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the FXO Timing Parameters Table for
|
|
each FXO interface."
|
|
AUGMENTS { cvaIfFXOCfgEntry }
|
|
::= { cvaIfFXOTimingTable 1 }
|
|
|
|
CvaIfFXOTimingEntry ::=
|
|
SEQUENCE {
|
|
cvaIfFXOTimingDigitDuration Integer32,
|
|
cvaIfFXOTimingInterDigitDuration Integer32,
|
|
cvaIfFXOTimingPulseRate Integer32,
|
|
cvaIfFXOTimingPulseInterDigitDuration Integer32
|
|
}
|
|
|
|
cvaIfFXOTimingDigitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (50..500)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing DTMF digit duration in milliseconds.
|
|
"
|
|
DEFVAL { 100 }
|
|
::= { cvaIfFXOTimingEntry 1 }
|
|
|
|
cvaIfFXOTimingInterDigitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (50..500)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing DTMF inter-digit duration in milliseconds.
|
|
"
|
|
DEFVAL { 100 }
|
|
::= { cvaIfFXOTimingEntry 2 }
|
|
|
|
cvaIfFXOTimingPulseRate OBJECT-TYPE
|
|
SYNTAX Integer32 (10..20)
|
|
UNITS "pulses per second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing pulse dialing rate in pulses per second (pps).
|
|
"
|
|
DEFVAL { 10 }
|
|
::= { cvaIfFXOTimingEntry 3 }
|
|
|
|
cvaIfFXOTimingPulseInterDigitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (100..1000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing pulse dialing inter-digit timing in milliseconds.
|
|
"
|
|
DEFVAL { 500 }
|
|
::= { cvaIfFXOTimingEntry 4 }
|
|
|
|
|
|
--****************************************************************************
|
|
-- The Foreign Exchange Station (FXS) Standard Configuration Table
|
|
--****************************************************************************
|
|
|
|
-- This table is used to configure the FXS signaling type, Ring frequency
|
|
|
|
cvaIfFXSCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfFXSCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The FXS standard configuration table. It contains
|
|
FXS configuration parameters, one entry per FXS interface.
|
|
The configuration information of this table is set by
|
|
hardware with its default setting or CLI during the hardware
|
|
installation time.
|
|
"
|
|
::= { cvaIfFXSObjects 1 }
|
|
|
|
cvaIfFXSCfgEntry OBJECT-TYPE
|
|
SYNTAX CvaIfFXSCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the standard configuration table for
|
|
each FXS interface."
|
|
INDEX { ifIndex }
|
|
::= { cvaIfFXSCfgTable 1 }
|
|
|
|
CvaIfFXSCfgEntry ::=
|
|
SEQUENCE {
|
|
cvaIfFXSCfgSignalType INTEGER,
|
|
cvaIfFXSRingFrequency INTEGER
|
|
}
|
|
|
|
cvaIfFXSCfgSignalType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fxsLoopStart (1),
|
|
fxsGroundStart (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the signaling type of FXS interface.
|
|
fxsLoopStart - loop start.
|
|
fxsGroundStart - ground start.
|
|
"
|
|
DEFVAL { fxsLoopStart }
|
|
::= { cvaIfFXSCfgEntry 1 }
|
|
|
|
cvaIfFXSRingFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ringFrequency25 (1),
|
|
ringFrequency50 (2),
|
|
ringFrequency20 (3),
|
|
ringFrequency30 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the ring frequency to be used in the FXS interface.
|
|
ringFrequency25 - ring frequency 25 Hertz.
|
|
ringFrequency50 - ring frequency 50 Hertz.
|
|
ringFrequency20 - ring frequency 20 Hertz.
|
|
ringFrequency30 - ring frequency 30 Hertz.
|
|
"
|
|
::= { cvaIfFXSCfgEntry 2 }
|
|
|
|
--****************************************************************************
|
|
-- The Foreign Exchange Station (FXS) interface Status Table
|
|
--****************************************************************************
|
|
|
|
cvaIfFXSStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfFXSStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Foreign Exchange Station (FXS) interface Status Table.
|
|
It contains hook status, ring active and other states of
|
|
the interface.
|
|
"
|
|
::= { cvaIfFXSObjects 2 }
|
|
|
|
cvaIfFXSStatusEntry OBJECT-TYPE
|
|
SYNTAX CvaIfFXSStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the status table for each FXS interface.
|
|
"
|
|
AUGMENTS { cvaIfFXSCfgEntry }
|
|
::= { cvaIfFXSStatusTable 1 }
|
|
|
|
CvaIfFXSStatusEntry ::=
|
|
SEQUENCE {
|
|
cvaIfFXSHookStatus INTEGER,
|
|
cvaIfFXSRingActive TruthValue,
|
|
cvaIfFXSRingGround TruthValue,
|
|
cvaIfFXSTipGround TruthValue
|
|
}
|
|
|
|
cvaIfFXSHookStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
onHook (1),
|
|
offHook (2),
|
|
trunked (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the hook status of FXS interface.
|
|
onHook - the connected equipment(e.g., phone) is onHook.
|
|
offHook - the connected equipment is offHook.
|
|
trunked - the connected equipment is trunked.
|
|
"
|
|
::= { cvaIfFXSStatusEntry 1 }
|
|
|
|
|
|
cvaIfFXSRingActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the outgoing ring active indication. If
|
|
the object value is true, then the interface is currently
|
|
generating ring out to the Key Telephone System (KTS) or
|
|
Plain Old Telephone (POT); otherwise, it doesn't.
|
|
"
|
|
::= { cvaIfFXSStatusEntry 2 }
|
|
|
|
cvaIfFXSRingGround OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the incoming ring ground indication.
|
|
It is only valid when the cvaIfFXSCfgSignalType is
|
|
fxsGroundStart. If the object is true, then the interface
|
|
is presenting a ring ground to the connected equipment;
|
|
otherwise, it doesn't.
|
|
"
|
|
::= { cvaIfFXSStatusEntry 3 }
|
|
|
|
cvaIfFXSTipGround OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the incoming tip ground indication.
|
|
It is only valid when the cvaIfFXSCfgSignalType is
|
|
fxsGroundStart. If the object is true, then the interface
|
|
is detecting a tip ground at the interface; otherwise,
|
|
it doesn't.
|
|
"
|
|
::= { cvaIfFXSStatusEntry 4 }
|
|
|
|
|
|
--****************************************************************************
|
|
-- The FXS Timing Parameters Table
|
|
--****************************************************************************
|
|
-- This table contains the FXS interface timing parameters information.
|
|
|
|
cvaIfFXSTimingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CvaIfFXSTimingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The FXS interface Timing Parameters table. It
|
|
contains the configuration of the various FXS signaling
|
|
protocol timing parameters.
|
|
"
|
|
::= { cvaIfFXSObjects 3 }
|
|
|
|
cvaIfFXSTimingEntry OBJECT-TYPE
|
|
SYNTAX CvaIfFXSTimingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the FXS Timing Parameters Table for
|
|
each FXS interface."
|
|
AUGMENTS { cvaIfFXSCfgEntry }
|
|
::= { cvaIfFXSTimingTable 1 }
|
|
|
|
CvaIfFXSTimingEntry ::=
|
|
SEQUENCE {
|
|
cvaIfFXSTimingDigitDuration Integer32,
|
|
cvaIfFXSTimingInterDigitDuration Integer32
|
|
}
|
|
|
|
|
|
|
|
cvaIfFXSTimingDigitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (50..500)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing DTMF digit duration in milliseconds.
|
|
"
|
|
DEFVAL { 100 }
|
|
::= { cvaIfFXSTimingEntry 1 }
|
|
|
|
cvaIfFXSTimingInterDigitDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (50..500)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing DTMF inter-digit duration in milliseconds.
|
|
"
|
|
DEFVAL { 100 }
|
|
::= { cvaIfFXSTimingEntry 2 }
|
|
|
|
|
|
--****************************************************************************
|
|
-- Conformance and compliance statements
|
|
--****************************************************************************
|
|
|
|
-- conformance information
|
|
|
|
cvaIfMIBConformance
|
|
OBJECT IDENTIFIER ::= { ciscoVoiceAnalogIfMIB 3 }
|
|
cvaIfMIBCompliances
|
|
OBJECT IDENTIFIER ::= { cvaIfMIBConformance 1 }
|
|
cvaIfMIBGroups
|
|
OBJECT IDENTIFIER ::= { cvaIfMIBConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
cvaIfMIBCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated -- superceded by cvaIfMIBCompliance2
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the Cisco Analog Voice interface MIB"
|
|
MODULE -- compliance to this module
|
|
MANDATORY-GROUPS {
|
|
cvaIfGeneralGroup
|
|
}
|
|
GROUP cvaIfEMGroup
|
|
DESCRIPTION
|
|
"The E&M group is mandatory for devices that have the
|
|
E&M interfaces."
|
|
|
|
GROUP cvaIfFXOGroup
|
|
DESCRIPTION
|
|
"The FXO group is mandatory for devices that have the
|
|
FXO interfaces."
|
|
|
|
GROUP cvaIfFXSGroup
|
|
DESCRIPTION
|
|
"The FXS group is mandatory for devices that have the
|
|
FXO interfaces."
|
|
|
|
OBJECT cvaIfCfgImpedance
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfCfgIntegratedDSP
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfStatusInfoType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfMaintenanceMode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfStatusSignalErrors
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgOperation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgDialType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingPulseRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingPulseInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingClearWaitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxWinkWaitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxWinkDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingDelayStart
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxDelayDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMinDelayPulseWidth
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgNumberRings
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgSupDisconnect
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgDialType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingPulseRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingPulseInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSRingFrequency
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { cvaIfMIBCompliances 1 }
|
|
|
|
cvaIfMIBCompliance2 MODULE-COMPLIANCE
|
|
STATUS deprecated -- superceded by cvaIfMIBCompliance3
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the Cisco Analog Voice interface MIB"
|
|
MODULE -- compliance to this module
|
|
MANDATORY-GROUPS {
|
|
cvaIfGeneralGroup
|
|
}
|
|
GROUP cvaIfEMGroupRev1
|
|
DESCRIPTION
|
|
"The E&M group is mandatory for devices that
|
|
have the E&M interfaces."
|
|
|
|
GROUP cvaIfFXOGroup2
|
|
DESCRIPTION
|
|
"The FXO group is mandatory for devices that
|
|
have the FXO interfaces."
|
|
|
|
GROUP cvaIfFXSGroup
|
|
DESCRIPTION
|
|
"The FXS group is mandatory for devices that
|
|
have the FXO interfaces."
|
|
|
|
OBJECT cvaIfCfgImpedance
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfCfgIntegratedDSP
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfStatusInfoType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfMaintenanceMode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfStatusSignalErrors
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgOperation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgDialType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgLmrMCap
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgLmrECap
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingPulseRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingPulseInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingClearWaitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxWinkWaitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxWinkDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingDelayStart
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxDelayDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMinDelayPulseWidth
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingVoiceHangover
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimeoutLmrTeardown
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
|
|
OBJECT cvaIfFXOCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgNumberRings
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgSupDisconnect2
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgDialType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingPulseRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingPulseInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSRingFrequency
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { cvaIfMIBCompliances 2 }
|
|
|
|
cvaIfMIBCompliance3 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the Cisco Analog Voice interface MIB"
|
|
MODULE -- compliance to this module
|
|
MANDATORY-GROUPS {
|
|
cvaIfGeneralGroup
|
|
}
|
|
GROUP cvaIfEMGroupRev2
|
|
DESCRIPTION
|
|
"The E&M group is mandatory for devices that
|
|
have the E&M interfaces."
|
|
|
|
GROUP cvaIfFXOGroup2
|
|
DESCRIPTION
|
|
"The FXO group is mandatory for devices that
|
|
have the FXO interfaces."
|
|
|
|
GROUP cvaIfFXSGroup
|
|
DESCRIPTION
|
|
"The FXS group is mandatory for devices that
|
|
have the FXO interfaces."
|
|
|
|
OBJECT cvaIfCfgImpedance
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfCfgIntegratedDSP
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfStatusInfoType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfMaintenanceMode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfStatusSignalErrors
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgOperation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgDialType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgLmrMCap
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgLmrECap
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMCfgAutoGainControl
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingPulseRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingPulseInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingClearWaitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxWinkWaitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxWinkDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingDelayStart
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMaxDelayDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingMinDelayPulseWidth
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingVoiceHangover
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimeoutLmrTeardown
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimeoutPttXmt
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimeoutPttRcv
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfEMTimingDelayVoice
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgNumberRings
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgSupDisconnect2
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOCfgDialType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingPulseRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXOTimingPulseInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSCfgSignalType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSRingFrequency
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSTimingDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cvaIfFXSTimingInterDigitDuration
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { cvaIfMIBCompliances 3 }
|
|
|
|
-- units of conformance
|
|
|
|
cvaIfGeneralGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cvaIfCfgIntegratedDSP,
|
|
cvaIfCfgImpedance,
|
|
cvaIfStatusInfoType,
|
|
cvaIfMaintenanceMode,
|
|
cvaIfStatusSignalErrors
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects providing general information
|
|
about the Cisco Analog Voice interfaces."
|
|
::= { cvaIfMIBGroups 1 }
|
|
|
|
cvaIfEMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cvaIfEMInSeizureActive,
|
|
cvaIfEMOutSeizureActive,
|
|
cvaIfEMCfgSignalType,
|
|
cvaIfEMCfgOperation,
|
|
cvaIfEMCfgType,
|
|
cvaIfEMCfgDialType,
|
|
cvaIfEMTimingDigitDuration,
|
|
cvaIfEMTimingInterDigitDuration,
|
|
cvaIfEMTimingPulseRate,
|
|
cvaIfEMTimingPulseInterDigitDuration,
|
|
cvaIfEMTimingClearWaitDuration,
|
|
cvaIfEMTimingMaxWinkWaitDuration,
|
|
cvaIfEMTimingMaxWinkDuration,
|
|
cvaIfEMTimingDelayStart,
|
|
cvaIfEMTimingMaxDelayDuration,
|
|
cvaIfEMTimingMinDelayPulseWidth
|
|
}
|
|
STATUS deprecated -- superceded by cvaIfEMGroupRev1
|
|
DESCRIPTION
|
|
"The collection of objects providing information
|
|
about the Cisco E&M trunk interface."
|
|
::= { cvaIfMIBGroups 2 }
|
|
|
|
cvaIfFXOGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cvaIfFXOHookStatus,
|
|
cvaIfFXORingDetect,
|
|
cvaIfFXORingGround,
|
|
cvaIfFXOTipGround,
|
|
cvaIfFXOCfgSignalType,
|
|
cvaIfFXOCfgNumberRings,
|
|
cvaIfFXOCfgSupDisconnect,
|
|
cvaIfFXOCfgDialType,
|
|
cvaIfFXOTimingDigitDuration,
|
|
cvaIfFXOTimingInterDigitDuration,
|
|
cvaIfFXOTimingPulseRate,
|
|
cvaIfFXOTimingPulseInterDigitDuration
|
|
}
|
|
STATUS deprecated -- superceded by cvaIfFXOGroup2
|
|
DESCRIPTION
|
|
"The collection of objects providing information
|
|
about the Cisco FXO interface."
|
|
::= { cvaIfMIBGroups 3 }
|
|
|
|
cvaIfFXSGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cvaIfFXSHookStatus,
|
|
cvaIfFXSRingActive,
|
|
cvaIfFXSRingGround,
|
|
cvaIfFXSTipGround,
|
|
cvaIfFXSCfgSignalType,
|
|
cvaIfFXSRingFrequency,
|
|
cvaIfFXSTimingDigitDuration,
|
|
cvaIfFXSTimingInterDigitDuration
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects providing information
|
|
about the Cisco FXS interface."
|
|
::= { cvaIfMIBGroups 4 }
|
|
|
|
cvaIfFXOGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
cvaIfFXOHookStatus,
|
|
cvaIfFXORingDetect,
|
|
cvaIfFXORingGround,
|
|
cvaIfFXOTipGround,
|
|
cvaIfFXOCfgSignalType,
|
|
cvaIfFXOCfgNumberRings,
|
|
cvaIfFXOCfgSupDisconnect2,
|
|
cvaIfFXOCfgDialType,
|
|
cvaIfFXOTimingDigitDuration,
|
|
cvaIfFXOTimingInterDigitDuration,
|
|
cvaIfFXOTimingPulseRate,
|
|
cvaIfFXOTimingPulseInterDigitDuration
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects providing information
|
|
about the Cisco FXO interface."
|
|
::= { cvaIfMIBGroups 5 }
|
|
cvaIfEMGroupRev1 OBJECT-GROUP
|
|
OBJECTS {
|
|
cvaIfEMInSeizureActive,
|
|
cvaIfEMOutSeizureActive,
|
|
cvaIfEMCfgSignalType,
|
|
cvaIfEMCfgOperation,
|
|
cvaIfEMCfgType,
|
|
cvaIfEMCfgDialType,
|
|
cvaIfEMTimingDigitDuration,
|
|
cvaIfEMTimingInterDigitDuration,
|
|
cvaIfEMTimingPulseRate,
|
|
cvaIfEMTimingPulseInterDigitDuration,
|
|
cvaIfEMTimingClearWaitDuration,
|
|
cvaIfEMTimingMaxWinkWaitDuration,
|
|
cvaIfEMTimingMaxWinkDuration,
|
|
cvaIfEMTimingDelayStart,
|
|
cvaIfEMTimingMaxDelayDuration,
|
|
cvaIfEMTimingMinDelayPulseWidth,
|
|
cvaIfEMCfgLmrMCap,
|
|
cvaIfEMCfgLmrECap,
|
|
cvaIfEMTimingVoiceHangover,
|
|
cvaIfEMTimeoutLmrTeardown
|
|
}
|
|
STATUS deprecated -- superceded by cvaIfEMGroupRev2
|
|
DESCRIPTION
|
|
"The collection of objects providing information
|
|
about the Cisco E&M trunk interface."
|
|
::= { cvaIfMIBGroups 6 }
|
|
|
|
cvaIfEMGroupRev2 OBJECT-GROUP
|
|
OBJECTS {
|
|
cvaIfEMInSeizureActive,
|
|
cvaIfEMOutSeizureActive,
|
|
cvaIfEMCfgSignalType,
|
|
cvaIfEMCfgOperation,
|
|
cvaIfEMCfgType,
|
|
cvaIfEMCfgDialType,
|
|
cvaIfEMTimingDigitDuration,
|
|
cvaIfEMTimingInterDigitDuration,
|
|
cvaIfEMTimingPulseRate,
|
|
cvaIfEMTimingPulseInterDigitDuration,
|
|
cvaIfEMTimingClearWaitDuration,
|
|
cvaIfEMTimingMaxWinkWaitDuration,
|
|
cvaIfEMTimingMaxWinkDuration,
|
|
cvaIfEMTimingDelayStart,
|
|
cvaIfEMTimingMaxDelayDuration,
|
|
cvaIfEMTimingMinDelayPulseWidth,
|
|
cvaIfEMCfgLmrMCap,
|
|
cvaIfEMCfgLmrECap,
|
|
cvaIfEMTimingVoiceHangover,
|
|
cvaIfEMTimeoutLmrTeardown,
|
|
cvaIfEMCfgAutoGainControl,
|
|
cvaIfEMTimeoutPttXmt,
|
|
cvaIfEMTimeoutPttRcv,
|
|
cvaIfEMTimingDelayVoice
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects providing information
|
|
about the Cisco E&M trunk interface."
|
|
::= { cvaIfMIBGroups 7 }
|
|
|
|
END
|
|
|
|
|
|
|