-- CISCO-METRO-PHY-MIB.my
|
|
--
|
|
-- Feb 2001, Sonal Maheshwari, Mickey Spiegel
|
|
-- May 2002, Sonal Maheshwari, Mickey Spiegel
|
|
-- Dec 2002, Arvind Prabhudev, Sonal Maheshwari, Mickey Spiegel
|
|
--
|
|
-- Copyright (c) 2001, 2002, 2003, 2004 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
CISCO-METRO-PHY-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Integer32,
|
|
Counter32,
|
|
Unsigned32,
|
|
Counter64,
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
TruthValue FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
ifIndex FROM IF-MIB
|
|
ciscoExperiment FROM CISCO-SMI
|
|
;
|
|
|
|
ciscoMetroPhyMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200411190000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO "Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-dwdm@cisco.com"
|
|
DESCRIPTION
|
|
"This MIB module defines the managed objects for physical
|
|
layer related interface configurations and objects
|
|
for the protocol specific error counters for DWDM
|
|
optical switches.
|
|
|
|
This MIB contains three groups.
|
|
|
|
The first group, cmPhyIf group, handles the physical layer
|
|
related interface configurations. The cmPhyIfTable has objects
|
|
for configuring protocol, rate, error monitoring, loopback
|
|
mode and safety features like OFC (Open Fibre Control), laser
|
|
safety control and forward laser control.
|
|
|
|
The second group, cmPhyStatistics group, represents the
|
|
counters that collect error statistics on the received
|
|
data traffic for all protocols except SONET.
|
|
The error statistics for SONET are covered
|
|
in the SONET-MIB.
|
|
|
|
The third group, cmPhySonetSectionTrace group, provides
|
|
objects for section trace monitoring on SONET/SDH
|
|
interfaces.
|
|
"
|
|
REVISION "200411190000Z"
|
|
DESCRIPTION
|
|
"cmPhyIfTransType object has been added to cmPhyIfTable.
|
|
'e1', 't1', 'e3', 't3', 'dvb', 'sdi' and 'its' enumeration
|
|
has been added to cmPhyIfProtocol object."
|
|
REVISION "200308250000Z"
|
|
DESCRIPTION
|
|
"cmPhyIfAutoNegotiation object has been added to cmPhyIfTable."
|
|
REVISION "200301080000Z"
|
|
DESCRIPTION
|
|
"cmPhyIfTxBufferSize object has been added to cmPhyIfTable."
|
|
REVISION "200205140000Z"
|
|
DESCRIPTION
|
|
"The third revision of this MIB.
|
|
|
|
The following new counters have been added -
|
|
cmPhyRxCRC,
|
|
cmPhyRxCRCOverflow,
|
|
cmPhyHCRxCRC,
|
|
cmPhyTxEncapFarEndPktErrors,
|
|
cmPhyTxEncapFarEndPktErrOverflow,
|
|
cmPhyHCTxEncapFarEndPktErrors
|
|
|
|
The following objects have been deprecated -
|
|
cmPhyIfLaserSafetyControl (moved to CISCO-OPTICAL-IF-EXTN-MIB),
|
|
cmPhyIfForwardLaserControl (moved to CISCO-OPTICAL-IF-EXTN-MIB),
|
|
cmPhyRxPower (moved to CISCO-OPTICAL-MONITOR-MIB),
|
|
cmPhyRxHEC (moved to CISCO-CDL-MIB),
|
|
cmPhyRxHECOverflow (moved to CISCO-CDL-MIB) and
|
|
cmPhyHCRxHEC (moved to CISCO-CDL-MIB).
|
|
"
|
|
REVISION "200108310000Z"
|
|
DESCRIPTION
|
|
"The second revision of this MIB."
|
|
REVISION "200104190000Z"
|
|
DESCRIPTION
|
|
"The initial revision of this MIB."
|
|
::= { ciscoExperiment 69 } -- assigned by CANA
|
|
|
|
|
|
-- Textual Conventions
|
|
|
|
TransmissionType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer value that identifies the physical layer medium
|
|
used across an interface.
|
|
|
|
The value 'unknown' indicates the physical layer medium is not
|
|
known.
|
|
|
|
The value 'copper' indicates the physical layer medium is
|
|
copper.
|
|
|
|
The value 'optical' indicates the physical layer medium is
|
|
optical."
|
|
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
copper(2),
|
|
optical(3)
|
|
}
|
|
|
|
ProtocolType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer value that identifies the protocol used across an
|
|
interface.
|
|
|
|
The value 'e1' indicates an interface that implements the
|
|
physical layer of E1.
|
|
|
|
The value 't1' indicates an interface that implements the
|
|
physical layer of T1.
|
|
|
|
The value 'e3' indicates an interface that implements the
|
|
physical layer of E3.
|
|
|
|
The value 't3' indicates an interface that implements the
|
|
physical layer of T3.
|
|
|
|
The value 'dvb' indicates an interface that implements the
|
|
physical layer of DVB.
|
|
|
|
The value 'sdi' indicates an interface that implements the
|
|
physical layer of SDI.
|
|
|
|
The value 'its' indicates an interface that implements the
|
|
physical layer of ITS. "
|
|
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
unknown(2),
|
|
gigabitEthernet(3),
|
|
tenGigabitEthernet(4),
|
|
fibreChannel(5),
|
|
ficon(6),
|
|
escon(7),
|
|
sonet(8),
|
|
sdh(9),
|
|
sysplexIscCompatibility(10),
|
|
sysplexIscPeer(11),
|
|
sysplexTimerEtr(12),
|
|
sysplexTimerClo(13),
|
|
fastEthernet(14),
|
|
fddi(15),
|
|
e1(16),
|
|
t1(17),
|
|
e3(18),
|
|
t3(19),
|
|
dvb(20),
|
|
sdi(21),
|
|
its(22)
|
|
}
|
|
|
|
TriValue ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A three codepoint value."
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2),
|
|
notApplicable(3)
|
|
}
|
|
|
|
-- MIB Object Definitions
|
|
|
|
ciscoMetroPhyMIBObjects OBJECT IDENTIFIER ::= { ciscoMetroPhyMIB 1 }
|
|
|
|
-- groups in this MIB module
|
|
|
|
cmPhyIf OBJECT IDENTIFIER
|
|
::= { ciscoMetroPhyMIBObjects 1 }
|
|
cmPhyStatistics OBJECT IDENTIFIER
|
|
::= { ciscoMetroPhyMIBObjects 2 }
|
|
cmPhySonetSectionTrace OBJECT IDENTIFIER
|
|
::= { ciscoMetroPhyMIBObjects 3 }
|
|
|
|
-- cmPhyIf group
|
|
|
|
-- This group handles the physical layer related interface
|
|
-- configurations, like the protocol and rate used across the client
|
|
-- side interface, monitoring of counters, enabling/disabling of OFC,
|
|
-- forward laser control, laser safety control and loopback mode
|
|
-- across client and trunk side interfaces.
|
|
|
|
-- PHY If Table
|
|
|
|
cmPhyIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmPhyIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table allows physical layer related interface
|
|
configurations on an interface."
|
|
::= { cmPhyIf 1 }
|
|
|
|
cmPhyIfEntry OBJECT-TYPE
|
|
SYNTAX CmPhyIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for configuration on an
|
|
interface."
|
|
INDEX { ifIndex }
|
|
::= { cmPhyIfTable 1 }
|
|
|
|
CmPhyIfEntry ::= SEQUENCE {
|
|
cmPhyIfMode INTEGER,
|
|
cmPhyIfProtocol ProtocolType,
|
|
cmPhyIfClockRate Integer32,
|
|
cmPhyIfMonitor TruthValue,
|
|
cmPhyIfLoopback INTEGER,
|
|
cmPhyIfOFC TruthValue,
|
|
cmPhyIfLaserSafetyControl TruthValue,
|
|
cmPhyIfForwardLaserControl TruthValue,
|
|
cmPhyIfTxBufferSize Unsigned32,
|
|
cmPhyIfAutoNegotiation TriValue,
|
|
cmPhyIfTransType TransmissionType
|
|
}
|
|
|
|
cmPhyIfMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mode2R(1),
|
|
mode3R(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the management client to configure
|
|
the mode of operation for the client interface modules.
|
|
|
|
When in 2R mode, there is no protocol type, clock rate
|
|
or monitoring to be configured i.e. the next three
|
|
objects would be read-only. When in 3R mode, monitoring
|
|
can be enabled or disabled and the clock rate and protocol
|
|
should be configured."
|
|
::= { cmPhyIfEntry 1 }
|
|
|
|
cmPhyIfProtocol OBJECT-TYPE
|
|
SYNTAX ProtocolType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to specify the protocol of the data
|
|
carried over the client side interface.
|
|
|
|
This object applies to linecards which support a variety of
|
|
protocols and allow dynamic configuration of the specific
|
|
protocol to be monitored on the interface. The ifType value
|
|
for such interfaces remains fixed. The agent may use this
|
|
object to identify the protocol to be monitored (see the
|
|
cmPhyIfMonitor object), to set the clock rate for the
|
|
interface (see the cmPhyIfClockRate object), or to enable
|
|
or disable functionality related to the protocol, for
|
|
example OFC (see the cmPhyIfOFC object).
|
|
|
|
The value of this object cannot be modified when the
|
|
cmPhyIfMonitor object is set to 'true' for that interface.
|
|
Also, this object does not apply to the trunk side
|
|
interfaces."
|
|
::= { cmPhyIfEntry 2 }
|
|
|
|
cmPhyIfClockRate OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10312000)
|
|
UNITS "kHz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the management client to set the
|
|
clock rate across the client side interface.
|
|
|
|
Due to hardware limitations, all values may not be supported.
|
|
The default value of this object depends on the value of the
|
|
cmPhyIfProtocol object. When the value of the cmPhyIfProtocol
|
|
object is reset, the value of this object will be
|
|
automatically set to the default for that protocol.
|
|
In case of protocols that support multiple rates,
|
|
the default value of this object will be the lowest rate
|
|
possible for that protocol. For example, if the value
|
|
of cmPhyIfProtocol is set to 'sonet', the default value
|
|
of cmPhyIfClockRate is set to the OC-3 rate of 155520 kHz.
|
|
If a non-default value is desired, then this object must
|
|
be set after the cmPhyIfProtocol object has been reset.
|
|
This object must be set to a supported clock rate when
|
|
setting cmPhyIfProtocol to 'unknown'.
|
|
In 2R mode of operation, this object is not applicable
|
|
and will have a default value of 0.
|
|
|
|
The value of this object cannot be modified when the
|
|
cmPhyIfMonitor object is set to 'true' for that interface.
|
|
Also, this object is not applicable to trunk side interfaces."
|
|
::= { cmPhyIfEntry 3 }
|
|
|
|
cmPhyIfMonitor OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the management client to enable
|
|
monitoring of the error counters on an interface,
|
|
by writing a value of 'true' to this object. To bypass
|
|
the monitoring hardware, a value of 'false' must be
|
|
written to this object.
|
|
|
|
Monitoring does not apply when the value of
|
|
cmPhyIfProtocol is 'unknown'."
|
|
::= { cmPhyIfEntry 4 }
|
|
|
|
cmPhyIfLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoop(1),
|
|
diagnosticLoop(2),
|
|
lineLoop(3),
|
|
otherLoop(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the management client to configure
|
|
loopback for the client side or trunk side interfaces.
|
|
|
|
'noLoop' - No Loopback present.
|
|
'diagnosticLoop' - This is an internal loopback, where the
|
|
data stream is looped from the transmit
|
|
to receive section. It is used for hardware
|
|
debug, bring-up and diagnostics.
|
|
'lineLoop' - In this mode, the receive data stream is
|
|
looped back to the transmit side.
|
|
'otherLoop' - This indicates loopbacks not defined here.
|
|
|
|
The default value of this object will be 'noLoop'."
|
|
::= { cmPhyIfEntry 5 }
|
|
|
|
cmPhyIfOFC OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the management client to enable
|
|
OFC(Open Fibre Control) safety protocol for the client
|
|
side interfaces, by writing a 'true' value to
|
|
this object. A 'false' value would disable OFC.
|
|
|
|
The default value of this object varies depending on the value
|
|
of cmPhyIfProtocol and cmPhyIfClockRate. When cmPhyIfProtocol
|
|
or cmPhyIfClockRate is reset, then the value of this object is
|
|
automatically reset to the default value for that protocol or
|
|
rate. If non-default OFC behavior is desired, then this object
|
|
should be set after cmPhyIfProtocol or cmPhyIfClockRate has
|
|
been reset.
|
|
|
|
This object is not applicable to trunk side interfaces."
|
|
::= { cmPhyIfEntry 6 }
|
|
|
|
cmPhyIfLaserSafetyControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object allows the management client to enable
|
|
laser safety control feature on the trunk side interfaces
|
|
by writing a true value to this object. If laser safety
|
|
control is enabled, the transmit laser on the trunk side is
|
|
shut when the receive signal is not available on the fiber.
|
|
A 'false' value disables this feature and is the default
|
|
value assigned to this object.
|
|
|
|
Laser safety control would not apply in case of splitter
|
|
protection on the optical switch."
|
|
::= { cmPhyIfEntry 7 }
|
|
|
|
cmPhyIfForwardLaserControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object allows the management client to enable
|
|
forward laser control on the client or trunk side interfaces
|
|
by writing a true value to this object. If forward laser
|
|
control is enabled, the transmit laser is shut when the
|
|
cross-connect receive port on the switch is in alarm
|
|
condition. A 'false' value disables this feature and is
|
|
the default value assigned to this object."
|
|
::= { cmPhyIfEntry 8 }
|
|
|
|
cmPhyIfTxBufferSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65536)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object applies when circuit emulation of the client
|
|
protocol is used. It allows the management client to
|
|
configure the size of the transmit buffer on the client
|
|
port. A value of 0 implies that this object does not apply
|
|
to this interface.
|
|
|
|
Controlling the size of the transmit buffer on a client
|
|
port may be essential in scenarios where packet streams
|
|
from various client ports are aggregated onto a single
|
|
trunk port. The latency associated with an elementary
|
|
stream received on a client port, from the trunk port is
|
|
influenced by the nature of other elementary streams in
|
|
the aggregate. For example, a giant packet in one stream
|
|
will increase latency in processing packets in other
|
|
elementary streams. The size of the transmit buffer on
|
|
the client port must be configured proportional to this
|
|
expected latency. Increasing the buffer size when latency
|
|
is higher helps in reassembly of fragmented packets before
|
|
transmitting them to the client device.
|
|
|
|
Note that increasing the buffer size results in higher
|
|
latency even when the elementary packet stream is not
|
|
subject to high jitters. Refer to the platform specific
|
|
documentation for guidelines on configuring this buffer
|
|
size."
|
|
::= { cmPhyIfEntry 9 }
|
|
|
|
cmPhyIfAutoNegotiation OBJECT-TYPE
|
|
SYNTAX TriValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the management client to enable
|
|
auto negotiation signaling on the client side interface,
|
|
by writing a 'true' value to this object. A 'false'
|
|
value would disable auto negotiation. Setting the value
|
|
'notApplicable' to this object will not change the
|
|
existing value in this object.
|
|
|
|
Auto negotiation is applicable only for a few client
|
|
protocols such as gigabitEthernet. If the client
|
|
interface does not support 'auto negotiation' feature,
|
|
then this object has the value of 'notApplicable' and
|
|
the value will not be changed via a set operation."
|
|
::= { cmPhyIfEntry 10 }
|
|
|
|
cmPhyIfTransType OBJECT-TYPE
|
|
SYNTAX TransmissionType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to identify the physical layer medium used
|
|
for carrying data. For non-relevant interfaces, this value is
|
|
'unknown'."
|
|
::= { cmPhyIfEntry 11 }
|
|
|
|
-- cmPhyStatistics group
|
|
|
|
-- This group contains objects for the error
|
|
-- counters for client data traffic, collected by the
|
|
-- monitoring hardware.
|
|
|
|
-- Statistics Table
|
|
|
|
cmPhyStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmPhyStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the cumulative error statistics being
|
|
collected for the different medium types, except SONET,
|
|
on the client side and an object for the optical
|
|
power level on the trunk side.
|
|
The error statistics for SONET are covered
|
|
by the sonetSectionCurrentTable and the
|
|
sonetSectionIntervalTable in the RFC1595-MIB."
|
|
::= { cmPhyStatistics 1 }
|
|
|
|
cmPhyStatisticsEntry OBJECT-TYPE
|
|
SYNTAX CmPhyStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the cmPhyStatisticsTable."
|
|
INDEX { ifIndex }
|
|
::= { cmPhyStatisticsTable 1 }
|
|
|
|
CmPhyStatisticsEntry ::= SEQUENCE {
|
|
cmPhyRxPower Integer32,
|
|
cmPhyRxCVRD Counter32,
|
|
cmPhyRxCVRDOverflow Counter32,
|
|
cmPhyHCRxCVRD Counter64,
|
|
cmPhyRxHEC Counter32,
|
|
cmPhyRxHECOverflow Counter32,
|
|
cmPhyHCRxHEC Counter64,
|
|
cmPhyRxCRC Counter32,
|
|
cmPhyRxCRCOverflow Counter32,
|
|
cmPhyHCRxCRC Counter64,
|
|
cmPhyTxEncapFarEndPktErrors Counter32,
|
|
cmPhyTxEncapFarEndPktErrOverflow Counter32,
|
|
cmPhyHCTxEncapFarEndPktErrors Counter64
|
|
}
|
|
|
|
cmPhyRxPower OBJECT-TYPE
|
|
SYNTAX Integer32 (-4000..0)
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object gives the optical power level received
|
|
on the trunk side interface.
|
|
|
|
The actual value of the power level received on
|
|
the interface is the value of this object divided
|
|
by 100. This object is not applicable to client side
|
|
interfaces.
|
|
|
|
This object has been deprecated since a similar object
|
|
has been defined in the CISCO-OPTICAL-MONITOR-MIB."
|
|
::= { cmPhyStatisticsEntry 1 }
|
|
|
|
cmPhyRxCVRD OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the lower word value of the
|
|
counter associated with the
|
|
number of code violations and running disparity errors
|
|
encountered, in the receive direction.
|
|
|
|
NOTE: The object cmPhyRxCVRDOverflow contains the
|
|
higher 32 bits of this counter value. SNMP v2c or v3
|
|
managers can use the cmPhyHCRxCVRD object
|
|
directly which is a 64 bit counter."
|
|
::= { cmPhyStatisticsEntry 2 }
|
|
|
|
cmPhyRxCVRDOverflow OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the high word value of the
|
|
counter associated with the
|
|
number of code violations and running disparity errors
|
|
encountered, in the receive direction.
|
|
|
|
NOTE: The object cmPhyRxCVRD contains the lower 32
|
|
bits of this counter value. If the error count is
|
|
greater than 4,294,967,295 the higher word value
|
|
will be stored in this object. SNMP v2c or v3
|
|
managers can use the cmPhyHCRxCVRD object
|
|
directly which is a 64 bit counter."
|
|
::= { cmPhyStatisticsEntry 3 }
|
|
|
|
cmPhyHCRxCVRD OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the counter associated with the
|
|
number of code violations and running disparity errors
|
|
encountered, in the receive direction.
|
|
|
|
This is a High Capacity (64 bit) version of the
|
|
cmPhyRxCVRD counter."
|
|
::= { cmPhyStatisticsEntry 4 }
|
|
|
|
cmPhyRxHEC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object represents the lower word value of the
|
|
counter associated with the
|
|
number of CDL HEC errors encountered, in the receive
|
|
direction.
|
|
|
|
This object has a valid value only if the protocol
|
|
type is gigabitEthernet/ tenGigabitEthernet. For all other
|
|
protocols, this object is not applicable.
|
|
|
|
NOTE: The object cmPhyRxHECOverflow contains the
|
|
higher 32 bits of this counter value. SNMP v2c or v3
|
|
managers can use the cmPhyHCRxHEC object
|
|
directly which is a 64 bit counter.
|
|
|
|
This object has been deprecated since a similar object
|
|
has been defined in the CISCO-CDL-MIB."
|
|
::= { cmPhyStatisticsEntry 5 }
|
|
|
|
cmPhyRxHECOverflow OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object represents the high word value of the
|
|
counter associated with the number of CDL
|
|
HEC errors encountered, in the receive direction.
|
|
|
|
This object has a valid value only if the protocol
|
|
type is gigabitEthernet/ tenGigabitEthernet. For all other
|
|
protocols, this object is not applicable.
|
|
|
|
NOTE: The object cmPhyRxHEC contains the lower 32
|
|
bits of this counter value. If the error count is
|
|
greater than 4,294,967,295 the higher word value
|
|
will be stored in this object. SNMP v2c or v3
|
|
managers can use the cmPhyHCRxHEC object
|
|
directly which is a 64 bit counter.
|
|
|
|
This object has been deprecated since a similar object
|
|
has been defined in the CISCO-CDL-MIB."
|
|
::= { cmPhyStatisticsEntry 6 }
|
|
|
|
cmPhyHCRxHEC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object represents the counter associated with the
|
|
number of CDL HEC errors encountered, in the receive
|
|
direction.
|
|
This object has a valid value only if the medium
|
|
type is gigabitEthernet/ tenGigabitEthernet. For all other
|
|
media, this object is not applicable.
|
|
|
|
This is a High Capacity (64 bit) version of the
|
|
cmPhyRxHEC counter.
|
|
|
|
This object has been deprecated since a similar object
|
|
has been defined in the CISCO-CDL-MIB."
|
|
::= { cmPhyStatisticsEntry 7 }
|
|
|
|
cmPhyRxCRC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the lower word value of the
|
|
counter associated with CRC errors.
|
|
This object has a valid value only for interfaces that
|
|
provide CRC error monitoring.
|
|
|
|
NOTE: The object cmPhyRxCRCOverflow contains the
|
|
higher 32 bits of this counter value. SNMP v2c or v3
|
|
managers can use the cmPhyHCRxCRC object
|
|
directly which is a 64 bit counter."
|
|
::= { cmPhyStatisticsEntry 8 }
|
|
|
|
cmPhyRxCRCOverflow OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the higher word value of the
|
|
counter associated with CRC errors.
|
|
This object has a valid value only for interfaces that
|
|
provide CRC error monitoring.
|
|
|
|
NOTE: The object cmPhyRxCRC contains the
|
|
lower 32 bits of this counter value. If the error count is
|
|
greater than 4,294,967,295 the higher word value
|
|
will be stored in this object. SNMP v2c or v3
|
|
managers can use the cmPhyHCRxCRC object
|
|
directly which is a 64 bit counter."
|
|
::= { cmPhyStatisticsEntry 9 }
|
|
|
|
cmPhyHCRxCRC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the counter associated with
|
|
CRC errors. This object has a valid value only for
|
|
interfaces that provide CRC error monitoring.
|
|
|
|
This is a High Capacity (64 bit) version of the cmPhyRxCRC
|
|
counter."
|
|
::= { cmPhyStatisticsEntry 10 }
|
|
|
|
cmPhyTxEncapFarEndPktErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the lower word value of the counter
|
|
associated with ingress error indications from the far end of
|
|
an Ethernet network, where an ESCON stream is encapsulated in
|
|
Ethernet packets. This counter is incremented whenever
|
|
an ESCON packet or control character has 8b/10b code
|
|
violations or running disparity errors in the ingress
|
|
direction at the far end of the Ethernet network.
|
|
|
|
This object has a valid value only for ESCON interfaces where
|
|
Ethernet encapsulation is performed.
|
|
|
|
NOTE: The object cmPhyTxEncapFarEndPktErrOverflow contains the
|
|
higher 32 bits of this counter value. SNMP v2c or v3
|
|
managers can use the cmPhyHCTxEsconPktInd object
|
|
directly which is a 64 bit counter."
|
|
::= { cmPhyStatisticsEntry 11 }
|
|
|
|
cmPhyTxEncapFarEndPktErrOverflow OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the higher word value of the counter
|
|
associated with ingress error indications from the far end of
|
|
an Ethernet network, where an ESCON stream is encapsulated in
|
|
Ethernet packets. This counter is incremented whenever
|
|
an ESCON packet or control character has 8b/10b code
|
|
violations or running disparity errors in the ingress
|
|
direction at the far end of the Ethernet network.
|
|
|
|
This object has a valid value only for ESCON interfaces where
|
|
Ethernet encapsulation is performed.
|
|
|
|
NOTE: The object cmPhyTxEncapFarEndPktErrors contains the
|
|
lower 32 bits of this counter value. SNMP v2c or v3
|
|
managers can use the cmPhyHCTxEsconPktInd object
|
|
directly which is a 64 bit counter."
|
|
::= { cmPhyStatisticsEntry 12 }
|
|
|
|
cmPhyHCTxEncapFarEndPktErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the counter associated with ESCON
|
|
ingress error indications from the far end of
|
|
an Ethernet network, where an ESCON stream is encapsulated in
|
|
Ethernet packets. This counter is incremented whenever
|
|
an ESCON packet or control character has 8b/10b code
|
|
violations or running disparity errors in the ingress
|
|
direction at the far end of the Ethernet network.
|
|
|
|
This object has a valid value only for ESCON interfaces where
|
|
Ethernet encapsulation is performed.
|
|
|
|
This is a High Capacity (64 bit) version of the
|
|
cmPhyTxEncapFarEndPktErrors counter."
|
|
::={ cmPhyStatisticsEntry 13 }
|
|
|
|
|
|
-- cmPhySonetSectionTrace group
|
|
|
|
-- This group provides objects for tracing a SONET section
|
|
-- by monitoring the J0 bytes of a received SONET or SDH frame.
|
|
|
|
-- SonetSectionTrace table
|
|
|
|
cmPhySonetSectionTraceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmPhySonetSectionTraceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides objects for monitoring the J0
|
|
bytes of a SONET or SDH section."
|
|
::= { cmPhySonetSectionTrace 1 }
|
|
|
|
cmPhySonetSectionTraceEntry OBJECT-TYPE
|
|
SYNTAX CmPhySonetSectionTraceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the cmPhySonetSectionTraceTable is created
|
|
when the value of the cmPhyIfProtocol object is set to
|
|
'sonet' and the value of cmPhyIfMonitor is set to 'true'."
|
|
INDEX { ifIndex }
|
|
::= { cmPhySonetSectionTraceTable 1 }
|
|
|
|
CmPhySonetSectionTraceEntry ::= SEQUENCE {
|
|
cmPhySonetSectionTraceReceived OCTET STRING,
|
|
cmPhySonetSectionTraceExpected OCTET STRING
|
|
}
|
|
|
|
cmPhySonetSectionTraceReceived OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0|16|64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the SONET or SDH section trace bytes
|
|
received at the interface."
|
|
::= { cmPhySonetSectionTraceEntry 1 }
|
|
|
|
cmPhySonetSectionTraceExpected OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0|16|64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the SONET or SDH section trace bytes
|
|
to be expected at the interface.
|
|
|
|
The default value of this object will be a zero length
|
|
string."
|
|
::= { cmPhySonetSectionTraceEntry 2 }
|
|
|
|
-- MIB Conformance Statements
|
|
|
|
ciscoMetroPhyMIBConformance OBJECT IDENTIFIER ::=
|
|
{ ciscoMetroPhyMIB 3 }
|
|
|
|
ciscoMetroPhyMIBCompliances OBJECT IDENTIFIER ::=
|
|
{ ciscoMetroPhyMIBConformance 1 }
|
|
|
|
ciscoMetroPhyMIBGroups OBJECT IDENTIFIER ::=
|
|
{ ciscoMetroPhyMIBConformance 2 }
|
|
|
|
cmPhyMIBCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for platforms that monitor the
|
|
operating status with respect to error
|
|
counters, for the physical layer."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmPhyIfGroup,
|
|
cmPhyStatisticsGroup
|
|
}
|
|
|
|
GROUP cmPhySonetSectionTraceGroup
|
|
DESCRIPTION
|
|
"Required for entities that support SONET/SDH section
|
|
trace."
|
|
|
|
OBJECT cmPhyIfMode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required if only one mode is
|
|
supported."
|
|
|
|
OBJECT cmPhyIfProtocol
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple protocols are supported on the interface."
|
|
|
|
OBJECT cmPhyIfClockRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple clock rates are supported on the interface."
|
|
|
|
OBJECT cmPhyIfMonitor
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfOFC
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { ciscoMetroPhyMIBCompliances 1 }
|
|
|
|
cmPhyMIBCompliance2 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for platforms that monitor the
|
|
operating status with respect to error
|
|
counters, for the physical layer."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmPhyIf2Group
|
|
}
|
|
|
|
GROUP cmPhyCVRDErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support code violation
|
|
and running disparity error counters."
|
|
|
|
GROUP cmPhyCRCErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support
|
|
CRC error counters."
|
|
|
|
GROUP cmPhyEncapFarEndPktErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support
|
|
far end ingress error indication counters for Ethernet-
|
|
encapsulated ESCON streams."
|
|
|
|
GROUP cmPhySonetSectionTraceGroup
|
|
DESCRIPTION
|
|
"Required for entities that support SONET/SDH section
|
|
trace."
|
|
|
|
OBJECT cmPhyIfMode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required if only one mode is
|
|
supported."
|
|
|
|
OBJECT cmPhyIfProtocol
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple protocols are supported on the interface."
|
|
|
|
OBJECT cmPhyIfClockRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple clock rates are supported on the interface."
|
|
|
|
OBJECT cmPhyIfMonitor
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfOFC
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { ciscoMetroPhyMIBCompliances 2 }
|
|
|
|
|
|
cmPhyMIBCompliance3 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for platforms that monitor the
|
|
operating status with respect to error
|
|
counters, for the physical layer."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmPhyIf2Group
|
|
}
|
|
|
|
GROUP cmPhyCVRDErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support code violation
|
|
and running disparity error counters."
|
|
|
|
GROUP cmPhyCRCErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support
|
|
CRC error counters."
|
|
|
|
GROUP cmPhyEncapFarEndPktErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support
|
|
far end ingress error indication counters for Ethernet-
|
|
encapsulated ESCON streams."
|
|
|
|
GROUP cmPhySonetSectionTraceGroup
|
|
DESCRIPTION
|
|
"Required for entities that support SONET/SDH section
|
|
trace."
|
|
|
|
GROUP cmPhyIfTxBufferSizeGroup
|
|
DESCRIPTION
|
|
"Required for entities that support control of transmit
|
|
buffer size."
|
|
|
|
OBJECT cmPhyIfMode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required if only one mode is
|
|
supported."
|
|
|
|
OBJECT cmPhyIfProtocol
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple protocols are supported on the interface."
|
|
|
|
OBJECT cmPhyIfClockRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple clock rates are supported on the interface."
|
|
|
|
OBJECT cmPhyIfMonitor
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfOFC
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfTxBufferSize
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { ciscoMetroPhyMIBCompliances 3 }
|
|
|
|
|
|
cmPhyMIBComplianceRev4 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for platforms that monitor the
|
|
operating status with respect to error
|
|
counters, for the physical layer."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmPhyIf2Group
|
|
}
|
|
|
|
GROUP cmPhyCVRDErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support code violation
|
|
and running disparity error counters."
|
|
|
|
GROUP cmPhyCRCErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support
|
|
CRC error counters."
|
|
|
|
GROUP cmPhyEncapFarEndPktErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support
|
|
far end ingress error indication counters for Ethernet-
|
|
encapsulated ESCON streams."
|
|
|
|
GROUP cmPhySonetSectionTraceGroup
|
|
DESCRIPTION
|
|
"Required for entities that support SONET/SDH section
|
|
trace."
|
|
|
|
GROUP cmPhyIfTxBufferSizeGroup
|
|
DESCRIPTION
|
|
"Required for entities that support control of transmit
|
|
buffer size."
|
|
|
|
GROUP cmPhyIfAutoNegGroup
|
|
DESCRIPTION
|
|
"Required for entities that support auto negotiation
|
|
on the client interface."
|
|
|
|
OBJECT cmPhyIfMode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required if only one mode is
|
|
supported."
|
|
|
|
OBJECT cmPhyIfProtocol
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple protocols are supported on the interface."
|
|
|
|
OBJECT cmPhyIfClockRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple clock rates are supported on the interface."
|
|
|
|
OBJECT cmPhyIfMonitor
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfOFC
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfTxBufferSize
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfAutoNegotiation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { ciscoMetroPhyMIBCompliances 4 }
|
|
|
|
|
|
|
|
cmPhyMIBComplianceRev5 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for platforms that monitor the
|
|
operating status with respect to error
|
|
counters, for the physical layer."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cmPhyIf2Group
|
|
}
|
|
|
|
GROUP cmPhyCVRDErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support code violation
|
|
and running disparity error counters."
|
|
|
|
GROUP cmPhyCRCErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support
|
|
CRC error counters."
|
|
|
|
GROUP cmPhyEncapFarEndPktErrorsGroup
|
|
DESCRIPTION
|
|
"Required only for entities that support
|
|
far end ingress error indication counters for Ethernet-
|
|
encapsulated ESCON streams."
|
|
|
|
GROUP cmPhySonetSectionTraceGroup
|
|
DESCRIPTION
|
|
"Required for entities that support SONET/SDH section
|
|
trace."
|
|
|
|
GROUP cmPhyIfTxBufferSizeGroup
|
|
DESCRIPTION
|
|
"Required for entities that support control of transmit
|
|
buffer size."
|
|
|
|
GROUP cmPhyIfAutoNegGroup
|
|
DESCRIPTION
|
|
"Required for entities that support auto negotiation
|
|
on the client interface."
|
|
|
|
GROUP cmPhyIfGroupSup1
|
|
DESCRIPTION
|
|
"Required for entities that have different transmission
|
|
types on the client interface."
|
|
|
|
OBJECT cmPhyIfMode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required if only one mode is
|
|
supported."
|
|
|
|
OBJECT cmPhyIfProtocol
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple protocols are supported on the interface."
|
|
|
|
OBJECT cmPhyIfClockRate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is required only when 3R mode is supported
|
|
and multiple clock rates are supported on the interface."
|
|
|
|
OBJECT cmPhyIfMonitor
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfOFC
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfTxBufferSize
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cmPhyIfAutoNegotiation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::= { ciscoMetroPhyMIBCompliances 5 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
cmPhyIfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyIfMode,
|
|
cmPhyIfProtocol,
|
|
cmPhyIfClockRate,
|
|
cmPhyIfMonitor,
|
|
cmPhyIfLoopback,
|
|
cmPhyIfOFC,
|
|
cmPhyIfLaserSafetyControl,
|
|
cmPhyIfForwardLaserControl
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The collection of objects to allow configurations and give
|
|
information related to the physical layer characteristics
|
|
of an interface."
|
|
::= { ciscoMetroPhyMIBGroups 1 }
|
|
|
|
cmPhyStatisticsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyRxPower,
|
|
cmPhyRxCVRD,
|
|
cmPhyRxCVRDOverflow,
|
|
cmPhyHCRxCVRD,
|
|
cmPhyRxHEC,
|
|
cmPhyRxHECOverflow,
|
|
cmPhyHCRxHEC
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The collection of objects used to monitor the protocol
|
|
error counters on the client side and the power level
|
|
received on the trunk side."
|
|
::= { ciscoMetroPhyMIBGroups 2 }
|
|
|
|
cmPhySonetSectionTraceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhySonetSectionTraceReceived,
|
|
cmPhySonetSectionTraceExpected
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects used for monitoring the SONET section
|
|
trace bytes."
|
|
::= { ciscoMetroPhyMIBGroups 3 }
|
|
|
|
cmPhyIf2Group OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyIfMode,
|
|
cmPhyIfProtocol,
|
|
cmPhyIfClockRate,
|
|
cmPhyIfMonitor,
|
|
cmPhyIfLoopback,
|
|
cmPhyIfOFC
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects to allow configurations and give
|
|
information related to the physical layer characteristics
|
|
of an interface."
|
|
::= { ciscoMetroPhyMIBGroups 4 }
|
|
|
|
cmPhyCVRDErrorsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyRxCVRD,
|
|
cmPhyRxCVRDOverflow,
|
|
cmPhyHCRxCVRD
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used to monitor the code violation
|
|
and running disparity error counters."
|
|
::= { ciscoMetroPhyMIBGroups 5 }
|
|
|
|
cmPhyCRCErrorsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyRxCRC,
|
|
cmPhyRxCRCOverflow,
|
|
cmPhyHCRxCRC
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used to monitor CRC
|
|
error counters."
|
|
::= { ciscoMetroPhyMIBGroups 6 }
|
|
|
|
cmPhyEncapFarEndPktErrorsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyTxEncapFarEndPktErrors,
|
|
cmPhyTxEncapFarEndPktErrOverflow,
|
|
cmPhyHCTxEncapFarEndPktErrors
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used to monitor the
|
|
far end ingress error indication counters for Ethernet-
|
|
encapsulated ESCON streams."
|
|
::= { ciscoMetroPhyMIBGroups 7 }
|
|
|
|
cmPhyIfTxBufferSizeGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyIfTxBufferSize
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used to control size of
|
|
transmit buffer."
|
|
::= { ciscoMetroPhyMIBGroups 8 }
|
|
|
|
cmPhyIfAutoNegGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyIfAutoNegotiation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used to control auto
|
|
negotiation behavior."
|
|
::= { ciscoMetroPhyMIBGroups 9 }
|
|
|
|
cmPhyIfGroupSup1 OBJECT-GROUP
|
|
OBJECTS {
|
|
cmPhyIfTransType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object that gives information related to transmission
|
|
types on the client interface."
|
|
::= { ciscoMetroPhyMIBGroups 10 }
|
|
|
|
|
|
END
|