mirror of
https://github.com/hsnodgrass/snmp_mib_archive.git
synced 2025-04-17 16:03:04 +00:00
706 lines
27 KiB
Plaintext
706 lines
27 KiB
Plaintext
-- $Id $
|
|
-- $Source $
|
|
-- ******************************************************************
|
|
-- CISCO-CDMA-AHDLC-MIB.my CDMA AHDLC Service Adapter Management MIB
|
|
--
|
|
-- Oct. 2000, Christian Pechard
|
|
-- Copyright (c) 2000-2005 by Cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- ******************************************************************
|
|
-- $Log $
|
|
-- ******************************************************************
|
|
-- $Endlog$
|
|
|
|
CISCO-CDMA-AHDLC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE,
|
|
OBJECT-TYPE,
|
|
Unsigned32,
|
|
Gauge32
|
|
FROM SNMPv2-SMI
|
|
|
|
TruthValue,
|
|
TimeStamp
|
|
FROM SNMPv2-TC
|
|
|
|
MODULE-COMPLIANCE,
|
|
NOTIFICATION-GROUP,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
|
|
ZeroBasedCounter32
|
|
FROM RMON2-MIB
|
|
|
|
ciscoMgmt
|
|
FROM CISCO-SMI
|
|
|
|
EntPhysicalIndexOrZero
|
|
FROM CISCO-TC;
|
|
|
|
|
|
cCdmaAhdlcMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200511140000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" Cisco Systems
|
|
Customer Service
|
|
|
|
Postal 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel +1 800 553-NETS
|
|
|
|
E-mail cs-pdsn@cisco.com"
|
|
|
|
DESCRIPTION
|
|
"This MIB module provides details concerning AHDLC
|
|
engine state, performance, configuration and
|
|
notification.
|
|
|
|
An AHDLC channel handles one AHDLC session.
|
|
AN AHDLC engine controls a set of AHDLC channels.
|
|
|
|
The following diagram illustrates a typical usage
|
|
of an AHDLC service adapter in a 3G CDMA wireless
|
|
data network
|
|
|
|
+==========+ +========+==========+
|
|
| RAdio | AHDLC packets |AHDLC | |
|
|
| Network |============== |engine | PDSN |
|
|
| (RAN) | | | router |
|
|
+==========+ +--------+ |
|
|
/|\ | |
|
|
| +===================+
|
|
Mobile Node
|
|
using PPP
|
|
over AHDLC
|
|
|
|
Two types of AHDLC engines are available -
|
|
software and hardware based. A dedicated hardware
|
|
allows better ahdlc framing performance.
|
|
|
|
|
|
Acronyms and terms
|
|
|
|
AHDLC Asynchronous High-level Data
|
|
Link Control.
|
|
|
|
AHDLC A dedicated resource used to
|
|
channel handle one AHDLC session.
|
|
|
|
|
|
AHDLC An entity managing a group of
|
|
engine AHDLC channels. An AHDLC engine
|
|
may be hardware assisted.
|
|
|
|
CDMA Code Division Multiple Access.
|
|
|
|
PDSN Packet Data Serving Node, a router
|
|
connecting a CDMA wireless network
|
|
to the internet.
|
|
|
|
RAN Radio Network."
|
|
|
|
REVISION "200511140000Z"
|
|
DESCRIPTION
|
|
"Updated the imports such that Unsigned32 is imported from
|
|
SNMPv2-SMI instead of CISCO-TC."
|
|
REVISION "200201040000Z"
|
|
DESCRIPTION
|
|
"Initial revision of this MIB module."
|
|
::= { ciscoMgmt 997 }
|
|
|
|
|
|
cCdmaAhdlcMIBObjects OBJECT IDENTIFIER ::= { cCdmaAhdlcMIB 1 }
|
|
cCdmaAhdlcEngineInfo OBJECT IDENTIFIER ::= { cCdmaAhdlcMIBObjects 1 }
|
|
cCdmaAhdlcMIBNotif OBJECT IDENTIFIER ::= { cCdmaAhdlcMIB 0 }
|
|
|
|
|
|
-- ******************************************************************
|
|
|
|
-- * CDMA AHDLC engine information
|
|
-- ******************************************************************
|
|
|
|
cCdmaAhdlcEngineTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CCdmaAhdlcEngineEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of AHDLC engines available in the system."
|
|
::= { cCdmaAhdlcEngineInfo 1 }
|
|
|
|
cCdmaAhdlcEngineEntry OBJECT-TYPE
|
|
SYNTAX CCdmaAhdlcEngineEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of an AHDLC engine."
|
|
INDEX { cCdmaAhdlcEngineIndex }
|
|
|
|
::= { cCdmaAhdlcEngineTable 1 }
|
|
|
|
CCdmaAhdlcEngineEntry ::=
|
|
SEQUENCE {
|
|
cCdmaAhdlcEngineIndex Unsigned32,
|
|
cCdmaAhdlcEngineName SnmpAdminString,
|
|
cCdmaAhdlcEngineType INTEGER,
|
|
cCdmaAhdlcEngineChannelsInUse Gauge32,
|
|
cCdmaAhdlcEngineMaxChannels Unsigned32,
|
|
cCdmaAhdlcEngineConfMaxChannels Unsigned32,
|
|
cCdmaAhdlcEngineOperState INTEGER,
|
|
cCdmaAhdlcEngineAdminState INTEGER,
|
|
cCdmaAhdlcEngineDownNotifEnabled TruthValue,
|
|
cCdmaAhdlcPhysicalIndex EntPhysicalIndexOrZero
|
|
}
|
|
|
|
cCdmaAhdlcEngineIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary non-zero integer-value that uniquely
|
|
identifies an AHDLC engine. An implementation should
|
|
assign AHDLC engines consecutive monotonically
|
|
increasing values."
|
|
::={ cCdmaAhdlcEngineEntry 1 }
|
|
|
|
cCdmaAhdlcEngineName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual name of the AHDLC engine. The value of this
|
|
object should be the name of the component as
|
|
assigned by the local device."
|
|
::={ cCdmaAhdlcEngineEntry 2 }
|
|
|
|
cCdmaAhdlcEngineType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
software(1),
|
|
hardware(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AHDLC engine type. Three main types are defined:
|
|
|
|
- a 'hardware' based engine requires the use of
|
|
AHDLC hardware assist. Each hardware based engine is
|
|
peer to one unique AHDLC hardware assist.
|
|
|
|
- a 'software' based engine is not peer to an AHDLC
|
|
hardware assist but it relies on the system cpu(s) to
|
|
perform AHDLC framing.
|
|
|
|
If the engine type cannot be determined, this object
|
|
value should return 'unknown'."
|
|
::={ cCdmaAhdlcEngineEntry 3 }
|
|
|
|
cCdmaAhdlcEngineChannelsInUse OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of current active channels handled by this
|
|
engine."
|
|
::={ cCdmaAhdlcEngineEntry 4 }
|
|
|
|
cCdmaAhdlcEngineMaxChannels OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of channels that can be supported
|
|
by this engine."
|
|
::={ cCdmaAhdlcEngineEntry 5 }
|
|
|
|
cCdmaAhdlcEngineConfMaxChannels OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of channels configured by the user.
|
|
This value may not be higher than
|
|
cCdmaAhdlcEngineMaxChannels."
|
|
::={ cCdmaAhdlcEngineEntry 6 }
|
|
|
|
|
|
cCdmaAhdlcEngineOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the current AHDLC engine
|
|
operational state. The 'up' indicates the engine
|
|
is ready to receive ahdlc packets.
|
|
If cCdmaAhdlcEngineAdminState is 'down' then
|
|
cCdmaAhdlcEngineOperState should be 'down'. If
|
|
cCdmaAhdlcEngineAdminState is changed to 'up' then
|
|
cCdmaAhdlcEngineOperState should change to 'up'
|
|
if the engine is ready to receive ahdlc packets;
|
|
it should remain in the 'down' state if and only
|
|
if there is a fault that prevents it from going to
|
|
the 'up' state."
|
|
::={ cCdmaAhdlcEngineEntry 7 }
|
|
|
|
cCdmaAhdlcEngineAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the AHDLC engine desired
|
|
state. When a managed system initializes, all
|
|
interfaces start with 'down' state. As a result
|
|
of either explicit management action or per
|
|
configuration information retained by the managed
|
|
system, cCdmaAhdlcEngineAdminState is then changed
|
|
to either 'up' or remains in the 'down' state."
|
|
::={ cCdmaAhdlcEngineEntry 8 }
|
|
|
|
cCdmaAhdlcEngineDownNotifEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" 'true' indicates notification will be sent out
|
|
when cCdmaAhdlcEngineAdminState is 'up' and
|
|
cCdmaAhdlcEngineOperState is 'down'."
|
|
::={ cCdmaAhdlcEngineEntry 9 }
|
|
|
|
cCdmaAhdlcPhysicalIndex OBJECT-TYPE
|
|
SYNTAX EntPhysicalIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Corresponding AHDLC service adapter entry in
|
|
the ENTITY-MIB (RFC-2737). This object value should
|
|
return the corresponding entPhysicalIndex value of
|
|
the service adapter or 0 if it cannot be determined or
|
|
is not applicable."
|
|
::={ cCdmaAhdlcEngineEntry 10 }
|
|
|
|
|
|
|
|
-- ******************************************************************
|
|
-- * CDMA AHDLC performance table
|
|
-- ******************************************************************
|
|
|
|
cCdmaAhdlcPerfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CCdmaAhdlcPerfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of statistics for those AHDLC engines
|
|
supported by the system."
|
|
::={ cCdmaAhdlcEngineInfo 2 }
|
|
|
|
cCdmaAhdlcPerfEntry OBJECT-TYPE
|
|
SYNTAX CCdmaAhdlcPerfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statistics associated with an AHDLC engine."
|
|
AUGMENTS { cCdmaAhdlcEngineEntry }
|
|
::={ cCdmaAhdlcPerfTable 1 }
|
|
|
|
CCdmaAhdlcPerfEntry ::=
|
|
SEQUENCE {
|
|
cCdmaAhdlcOutgoingOctetsToEncode ZeroBasedCounter32,
|
|
cCdmaAhdlcOutgoingOctetsEncoded ZeroBasedCounter32,
|
|
cCdmaAhdlcOutgoingPktsToEncode ZeroBasedCounter32,
|
|
cCdmaAhdlcOutgoingPktsEncoded ZeroBasedCounter32,
|
|
cCdmaAhdlcIncomingOctetsToDecode ZeroBasedCounter32,
|
|
cCdmaAhdlcIncomingOctetsDecoded ZeroBasedCounter32,
|
|
cCdmaAhdlcIncomingPktsToDecode ZeroBasedCounter32,
|
|
cCdmaAhdlcIncomingPktsDecoded ZeroBasedCounter32,
|
|
cCdmaAhdlcDropPktsDec ZeroBasedCounter32,
|
|
cCdmaAhdlcDropPktsEnc ZeroBasedCounter32,
|
|
cCdmaAhdlcCRCDropPkts ZeroBasedCounter32,
|
|
cCdmaAhdlcMemDropPktsDec ZeroBasedCounter32,
|
|
cCdmaAhdlcMemDropPktsEnc ZeroBasedCounter32,
|
|
cCdmaAhdlcOverflowDropPktsDec ZeroBasedCounter32,
|
|
cCdmaAhdlcOverflowDropPktsEnc ZeroBasedCounter32,
|
|
cCdmaAhdlcInvSizeDropPktsDec ZeroBasedCounter32,
|
|
cCdmaAhdlcInvSizeDropPktsEnc ZeroBasedCounter32,
|
|
cCdmaAhdlcDiscontinuityTime TimeStamp
|
|
}
|
|
|
|
|
|
cCdmaAhdlcOutgoingOctetsToEncode OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of outgoing-traffic octets delivered to
|
|
the AHDLC engine for AHDLC encoding since system was
|
|
last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 1 }
|
|
|
|
cCdmaAhdlcOutgoingOctetsEncoded OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of outgoing-traffic octets generated by
|
|
the AHDLC engine through AHDLC encoding since system
|
|
was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 2 }
|
|
|
|
cCdmaAhdlcOutgoingPktsToEncode OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of outgoing-traffic packets delivered
|
|
to the AHDLC engine for AHDLC encoding since system
|
|
was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 3 }
|
|
|
|
cCdmaAhdlcOutgoingPktsEncoded OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of outgoing-traffic packets generated
|
|
by the AHDLC engine through AHDLC encoding since
|
|
system was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 4 }
|
|
|
|
cCdmaAhdlcIncomingOctetsToDecode OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of incoming-traffic octets delivered to
|
|
the AHDLC engine for AHDLC decoding since system was
|
|
last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 5 }
|
|
|
|
cCdmaAhdlcIncomingOctetsDecoded OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of incoming-traffic octets generated by
|
|
the AHDLC engine through AHDLC decoding since system
|
|
was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 6 }
|
|
|
|
cCdmaAhdlcIncomingPktsToDecode OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of incoming-traffic packets delivered
|
|
to the AHDLC engine for AHDLC decoding since system
|
|
was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 7 }
|
|
|
|
cCdmaAhdlcIncomingPktsDecoded OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of incoming-traffic packets generated
|
|
by the AHDLC engine through AHDLC decoding since
|
|
system was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 8 }
|
|
|
|
cCdmaAhdlcDropPktsDec OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine during
|
|
AHDLC decoding since system was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 9 }
|
|
|
|
cCdmaAhdlcDropPktsEnc OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine during
|
|
AHDLC encoding since system was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 10 }
|
|
|
|
cCdmaAhdlcCRCDropPkts OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine because
|
|
of CRC errors since system was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 11 }
|
|
|
|
cCdmaAhdlcMemDropPktsDec OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine due to
|
|
insufficient memory during AHDLC decoding since
|
|
system was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 12 }
|
|
|
|
cCdmaAhdlcMemDropPktsEnc OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine due to
|
|
insufficient memory during AHDLC encoding since
|
|
system was last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 13 }
|
|
|
|
cCdmaAhdlcOverflowDropPktsDec OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine due to
|
|
queue overflow during AHDLC decoding since system was
|
|
last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 14 }
|
|
|
|
cCdmaAhdlcOverflowDropPktsEnc OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine due to
|
|
queue overflow during AHDLC encoding since system was
|
|
last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 15 }
|
|
|
|
cCdmaAhdlcInvSizeDropPktsDec OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine due to
|
|
invalid size during AHDLC decoding since system was
|
|
last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 16 }
|
|
|
|
cCdmaAhdlcInvSizeDropPktsEnc OBJECT-TYPE
|
|
SYNTAX ZeroBasedCounter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets dropped by the engine due to
|
|
invalid size during AHDLC encoding since system was
|
|
last restarted.
|
|
|
|
Discontinuities in the value of this counter can occur
|
|
at re-initialization of the management system, and at
|
|
other times as indicated by the value of
|
|
cCdmaAhdlcDiscontinuityTime."
|
|
::={ cCdmaAhdlcPerfEntry 17 }
|
|
|
|
cCdmaAhdlcDiscontinuityTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the AHDLC Engine's
|
|
counters last experienced a discontinuity. If no
|
|
discontinuities have occurred since the last
|
|
re-initialization of the local management subsystem,
|
|
then this object contains a zero value."
|
|
::={ cCdmaAhdlcPerfEntry 18 }
|
|
|
|
-- ******************************************************************
|
|
-- Notification definitions
|
|
-- ******************************************************************
|
|
|
|
|
|
cCdmaAhdlcEngineDownNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cCdmaAhdlcEngineOperState,
|
|
cCdmaAhdlcEngineAdminState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates an AHDLC engine
|
|
is 'down' due to some fault though the desired
|
|
state of the engine is 'up'."
|
|
::={ cCdmaAhdlcMIBNotif 1 }
|
|
|
|
-- ******************************************************************
|
|
-- * Conformance
|
|
-- ******************************************************************
|
|
|
|
cCdmaAhdlcMIBConformance OBJECT IDENTIFIER ::={ cCdmaAhdlcMIB 3 }
|
|
cCdmaAhdlcMIBCompliances OBJECT IDENTIFIER
|
|
::={ cCdmaAhdlcMIBConformance 1 }
|
|
cCdmaAhdlcMIBGroups OBJECT IDENTIFIER
|
|
::={ cCdmaAhdlcMIBConformance 2 }
|
|
|
|
|
|
-- ******************************************************************
|
|
-- * Compliance
|
|
-- ******************************************************************
|
|
|
|
cCdmaAhdlcMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the CDMA AHDLC Management MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cCdmaAhdlcGroup,
|
|
cCdmaAhdlcNotifGroup
|
|
}
|
|
::={ cCdmaAhdlcMIBCompliances 1 }
|
|
|
|
-- ******************************************************************
|
|
-- * Units of Conformance
|
|
-- ******************************************************************
|
|
|
|
cCdmaAhdlcGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cCdmaAhdlcEngineName,
|
|
cCdmaAhdlcEngineType,
|
|
cCdmaAhdlcEngineMaxChannels,
|
|
cCdmaAhdlcEngineConfMaxChannels,
|
|
cCdmaAhdlcEngineChannelsInUse,
|
|
cCdmaAhdlcEngineOperState,
|
|
cCdmaAhdlcEngineAdminState,
|
|
cCdmaAhdlcEngineDownNotifEnabled,
|
|
cCdmaAhdlcPhysicalIndex,
|
|
cCdmaAhdlcOutgoingOctetsToEncode,
|
|
cCdmaAhdlcOutgoingOctetsEncoded,
|
|
cCdmaAhdlcOutgoingPktsToEncode,
|
|
cCdmaAhdlcOutgoingPktsEncoded,
|
|
cCdmaAhdlcIncomingOctetsToDecode,
|
|
cCdmaAhdlcIncomingOctetsDecoded,
|
|
cCdmaAhdlcIncomingPktsToDecode,
|
|
cCdmaAhdlcIncomingPktsDecoded,
|
|
cCdmaAhdlcDropPktsDec,
|
|
cCdmaAhdlcDropPktsEnc,
|
|
cCdmaAhdlcCRCDropPkts,
|
|
cCdmaAhdlcMemDropPktsDec,
|
|
cCdmaAhdlcMemDropPktsEnc,
|
|
cCdmaAhdlcOverflowDropPktsDec,
|
|
cCdmaAhdlcOverflowDropPktsEnc,
|
|
cCdmaAhdlcInvSizeDropPktsDec,
|
|
cCdmaAhdlcInvSizeDropPktsEnc,
|
|
cCdmaAhdlcDiscontinuityTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects needed for CDMA AHDLC network
|
|
management."
|
|
::={ cCdmaAhdlcMIBGroups 1 }
|
|
|
|
|
|
cCdmaAhdlcNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{
|
|
cCdmaAhdlcEngineDownNotif
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notifications related to CDMA AHDLC network
|
|
management."
|
|
::={ cCdmaAhdlcMIBGroups 2 }
|
|
|
|
END
|
|
|